Loading...
HomeMy WebLinkAbout05 - Vacancy Coffee Bar Minor Use Permit - PA2016-136 COMMUNITY DEVELOPMENT DEPARTMENT VPLANNING DIVISION low 100 Civic Center Drive, P.O. Box 1768, Newport Beach, CA 92658-8915 cq�iFOw�avP 949-644-3200 Fax: 949-644-3229 www.newportbeachca.gov CITY OF NEWPORT BEACH ZONING ADMINISTRATOR STAFF REPORT September 15, 2016 Agenda Item No. 5 SUBJECT: Vacancy Coffee Bar Minor Use Permit (PA2016-136) 6480 W. Coast Highway • Minor Use Permit No. UP2016-034 APPLICANT: Vacancy Coffee Bar OWNER: Brian Jeffrey Kennard PLANNER: Melinda Whelan, Assistant Planner (949) 644-3221, mwhelan@newportbeachca.gov ZONING DISTRICT/GENERAL PLAN • Zone: CG (Commercial General) • General Plan: CG (General Commercial) PROJECT SUMMARY A minor use permit to allow the operation of an approximately 500-square-foot take-out service limited, eating and drinking establishment in an existing office/ retail building. No late hours (after 11:00 p.m.) or alcohol service are proposed as part of this application. The proposal includes a maximum of 6 seats for patrons. RECOMMENDATION 1) Conduct a public hearing; and 2) Adopt Draft Zoning Administrator Resolution No. _ approving Minor Use Permit No. UP2016-034 (Attachment No. ZA 1). DISCUSSION • The subject property is located at the corner of West Coast Highway and Walnut Street and contains a 1,836-square-foot general office/retail building. The existing building is occupied by ourCaste which is an apparel company that uses 1 Vacancy Coffee Bar Minor Use Permit Zoning Administrator, September 15, 2016 Page 2 the space to fill mail orders and to showcase their clothing. Four parking spaces are available on-site for employees or patrons of the building. • The applicant proposes to convert a portion (approximately 500 square feet) of the existing 1,835-square-foot mail order show room and office (ourCaste Apparel Company) into a take-out service limited, eating and drinking establishment serving coffee. The proposal includes six seats for patrons. The proposed hours of operation are 7:30 a.m. to 3:30 p.m., daily. No late hours (after 11:00 p.m.) or alcohol service are proposed as part of this application. In order to allow for future flexibility, a condition of approval is included allowing hours of operation between 7 a.m. and 9 p.m., daily. • The proposal complies with Zoning Code standards for a take-out service limited, eating and drinking establishment, including the condition not to exceed a maximum of six seats. • The subject property is located in the Commercial General (CG) Zoning District. This designation applies to properties in which a wide variety of commercial activities oriented primarily to serve Citywide or regional needs. A take-out service limited, eating and drinking establishment is a permitted use in the Zoning District, subject to the approval of a minor use permit pursuant to Table 2- 5 of Newport Beach Municipal Code Section 20.20.020 (Commercial Zoning Districts Land Uses and Permit Requirements). • The property is designated General Commercial (CG) by the Land Use Element of the General Plan which is consistent in intent with the CG Zoning District. The proposed establishment is a commercial use intended to serve nearby residents, the surrounding community, and visitors to the City of Newport Beach. Therefore, the use is consistent with this land use category. • The property is nonconforming in parking because it is deficient in parking for the existing office use. Based on a general office/retail parking ratio of one space per 250 square feet, 8 spaces (1,835/250 = 7.344) are required. The property currently provides four spaces on-site. • Zoning Code Section 20.38.060 (Nonconforming Parking) allows a change of use on sites with nonconforming parking. It specifies that there must be no intensification or enlargement in floor area or lot area, and the new use requires a parking rate of no more than one space per 250 square feet. • The parking requirement for a take-out service limited, eating and drinking establishment is one space per 250 square feet, and no intensification or enlargement is proposed. Therefore, no additional parking is required. TmpIt:05-05-16 Vacancy Coffee Bar Minor Use Permit Zoning Administrator, September 15, 2016 Page 3 • Staff believes the proposed take-out service, limited eating and drinking establishment use will be complementary to the other uses in the building and will serve residents and visitors to the City. ENVIRONMENTAL REVIEW The project is categorically exempt under Section 15301, of the State CEQA (California Environmental Quality Act) Guidelines - Class 1 (Existing Facilities). The Class 1 exemption authorizes minor alterations to existing structures involving negligible or no expansion of use. The proposed project involves interior improvements to convert a previous retail use to a take-out service limited, eating and drinking establishment and does not result in an expansion of floor area or a change in parking requirement. PUBLIC NOTICE Notice of this application was published in the Daily Pilot, mailed to all owners of property within 300 feet of the boundaries of the site (excluding intervening rights-of- way and waterways), including the applicant, and posted on the subject property at least 10 days before the scheduled hearing, consistent with the provisions of the Municipal Code. Additionally, the item appeared on the agenda for this meeting, which was posted at City Hall and on the City website. APPEAL PERIOD: An appeal or call for review may be filed with the Director of Community Development within 14 days following the date of action. For additional information on filing an appeal, contact the Planning Division at (949) 644-3200. Prepared by: Melinda Whelan Assistant Planner GBR/msw Attachments: ZA 1 Draft Resolution ZA 2 Vicinity Map ZA 3 Project Plans TmpIt:05-05-16 Attachment No. ZA 1 Draft Resolution 4 RESOLUTION NO. ZA2016-### A RESOLUTION OF THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH APPROVING MINOR USE PERMIT NO. UP2016-034 FOR A TAKE-OUT SERVICE LIMITED, EATING AND DRINKING ESTABLISHMENT LOCATED AT 6480 WEST COAST HIGHWAY (PA2016-136) THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH HEREBY FINDS AS FOLLOWS: SECTION 1. STATEMENT OF FACTS. 1. An application was filed by Oliver Williams on behalf of Vacancy Coffee Bar, with respect to property located at 6480 West Coast Highway, and legally described as Lot 13 and the northeasterly half of Lot 14, Block 4 of Seashore Colony Tract, as shown on a map thereof recorded in Book 7, Page 25, Miscellaneous Maps, Records of Said Orange County in the City of Newport Beach requesting approval of a minor use permit. 2. The applicant proposes a minor use permit to allow the operation of a take-out service limited, eating and drinking establishment. No late hours (after 11:00 p.m.) or alcohol service are proposed as part of this application. A maximum of six seats are provided for patrons. 3. The subject property is located within the CG (Commercial General) Zoning District and the General Plan Land Use Element category is CG (General Commercial). 4. The subject property is located within the coastal zone. The Coastal Land Use Plan category is General Commercial (CG-B). 5. A public hearing was held on September 15, 2016, in the Corona del Mar Conference Room (Bay E-1st Floor) at 100 Civic Center Drive, Newport Beach. A notice of time, place and purpose of the meeting was given in accordance with the Newport Beach Municipal Code. Evidence, both written and oral, was presented to, and considered by, the Zoning Administrator at this meeting. SECTION 2. CALIFORNIA ENVIRONMENTAL QUALITY ACT DETERMINATION. 1. This project has been determined to be categorically exempt from the California Environmental Quality Act (CEQA) pursuant to Section 15301 under Class 1 (Existing Facilities) 2. This exemption authorizes minor alterations to existing structures involving negligible or no expansion of use. The proposed project involves alterations to the interior floor plan of an existing commercial space with no expansion in use. Zoning Administrator Resolution No. ZA2016-### Page 2 of 7 SECTION 3. REQUIRED FINDINGS. In accordance with Section 20.52.020 (Conditional Use Permits and Minor Use Permits) of the Newport Beach Municipal Code, the following findings and facts in support of such findings are set forth: Finding: A. The use is consistent with the General Plan and any applicable specific plan. Facts in Support of Finding: 1. The General Plan designates the site CG (General Commercial). This designation applies to properties intended to provide a variety of commercial activities oriented primarily to serve citywide or regional needs. 2. The proposed establishment is a commercial use intended to serve nearby residents, the surrounding community, and visitors to the City of Newport Beach. Therefore, it is consistent with the CG designation. 3. The proposed take-out service limited establishment would be complementary to the surrounding commercial and residential uses. 4. The subject property is not part of a specific plan area. Finding: B. The use is allowed within the applicable zoning district and complies with all other applicable provisions of this Zoning Code and the Municipal Code. Facts in Support of Finding: 1. The property is located in the Commercial General (CG) Zoning District. The proposed establishment, which includes accessory kitchen facilities (no oven or stove), six seats, no alcohol service, and no late hours, is a permitted use subject to the approval of a minor use permit pursuant to Newport Beach Municipal Code Section 20.20.020 (Commercial Retail Zoning Districts Land Uses and Permit Requirements). 2. The property is nonconforming in parking because it is deficient in parking for the nonresidential uses. Based on a general office or retail parking ratio of one space per 250 square feet, 8 spaces (1,836/250 = 7.344) are required. The property currently provides four spaces on-site. 3. Zoning Code Section 20.38.060 (Nonconforming Parking) allows a change of use on sites with nonconforming parking. It specifies that there must be no intensification or enlargement in floor area or lot area, and the new use requires a parking rate of no more than one space per 250 square feet. 05-26-2016 Zoning Administrator Resolution No. ZA2016-### Page 3 of 7 4. The parking requirement for a take-out service limited, eating and drinking establishment is one space per 250 square feet, and no intensification or enlargement is proposed. Therefore, no additional parking is required. 5. As conditioned, the proposed establishment will comply with Zoning Code standards for eating and drinking establishments, including those specific to the take-out service limited use classification, which includes a maximum of six seats. Finding: C. The design, location, size, and operating characteristics of the use are compatible with the allowed uses in the vicinity. Facts in Support of Finding: 1. The proposed establishment will be accessible from Walnut Street, West Coast Highway and the alley, which provide convenient access to motorists, pedestrians, and bicyclists. 2. The proposed establishment is compatible with the existing and allowed uses in the area. 3. As conditioned, the allowed hours of operation will be 7:00 a.m. to 9:00 p.m., daily, which will minimize any disturbance to residences near the property. 4. The existing trash storage area at the rear of the property is adequate to accommodate the proposed use. It is conveniently located where materials can be deposited and collected and does not impede with parking spaces. Finding: D. The site is physically suitable in terms of design, location, shape, size, operating characteristics, and the provision of public and emergency vehicle (e.g., fire and medical) access and public services and utilities. Facts in Support of Finding: 1. The existing parking lot provides adequate circulation for patrons. 2. The site has been reviewed by the Fire Department to ensure adequate public and emergency vehicle access is provided. 3. Any proposed site and tenant improvements will comply with the Zoning Code and all Building, Public Works, and Fire Codes. 05-26-2016 Zoning Administrator Resolution No. ZA2016-### Page 4of7 Finding: E. Operation of the use at the location proposed would not be detrimental to the harmonious and orderly growth of the City, nor endanger, jeopardize, or otherwise constitute a hazard to the public convenience, health, interest, safety, or general welfare of persons residing or working in the neighborhood of the proposed use. Facts in Support of Finding: 1. The project has been reviewed and includes conditions of approval to ensure that potential conflicts with the surrounding land uses are minimized to the greatest extent possible. The operator is required to take reasonable steps to discourage and correct objectionable conditions that constitute a nuisance in parking areas, sidewalks and areas surrounding the subject property and adjacent properties during business hours, if directly related to the patrons of the establishment. 2. The proposed take-out service, eating and drinking establishment will help revitalize the project site and provide an economic opportunity for the property owner to update the tenant space, and provide additional services to residents and visitors. 3. The applicant is required to obtain Health Department approval prior to opening for business, and comply with the California Building Code to ensure the safety and welfare of customers and employees within the establishment. SECTION 4. DECISION. NOW, THEREFORE, BE IT RESOLVED: 1. The Zoning Administrator of the City of Newport Beach hereby approves Minor Use Permit No. UP2016-034, subject to the conditions set forth in Exhibit A, which is attached hereto and incorporated by reference. PASSED, APPROVED, AND ADOPTED THIS 15TH DAY OF SEPTEMBER, 2016. Patrick J. Alford, Zoning Administrator 05-26-2016 g Zoning Administrator Resolution No. ZA2016-### Page 5 of 7 EXHIBIT "A" CONDITIONS OF APPROVAL PLANNING 1 . The development shall be in substantial conformance with the approved site plan and floor plans stamped and dated with the date of this approval. (Except as modified by applicable conditions of approval.) 2. The applicant shall comply with all federal, state, and local laws. Material violation of any of those laws in connection with the use may be cause for revocation of this Minor Use Permit. 3. This Minor Use Permit may be modified or revoked by the Zoning Administrator if determined that the proposed uses or conditions under which it is being operated or maintained is detrimental to the public health, welfare or materially injurious to property or improvements in the vicinity or if the property is operated or maintained so as to constitute a public nuisance. 4. The applicant is required to obtain all applicable permits from the City's Building Division and Fire Department. The construction plans must comply with the most recent, City- adopted version of the California Building Code. The construction plans must meet all applicable State Disabilities Access requirements. Approval from the Orange County Health Department is required prior to the issuance of a building permit. 5. The hours of operation for the establishment shall be limited to 7:00 a.m. through 9:00 p.m., daily. 6. The sale of alcohol shall not be permitted. 7. The maximum number of seats allowed in the eating and drinking establishment shall be six (6). No outdoor seating is permitted without further review and may require an amendment to this Minor Use Permit. 8. Any change in operational characteristics, expansion in area, or other modification to the approved plans, shall require an amendment to this Minor Use Permit or the processing of a new use permit. 9. A copy of the Resolution, including conditions of approval Exhibit "A", shall be incorporated into the Building Division and field sets of plans prior to issuance of the building permits. 10. Prior to issuance of building permits, the applicant shall submit to the Planning Division an additional copy of the approved architectural plans for inclusion in the Minor Use Permit file. The plans shall be identical to those approved by all City departments for 05-26-2016 9 Zoning Administrator Resolution No. ZA2016-### Page 6 of 7 building permit issuance. The approved copy shall include architectural sheets only and shall be reduced in size to 11 inches by 17 inches. The plans shall accurately depict the elements approved by this Minor Use Permit and shall highlight the approved elements such that they are readily discernible from other elements of the plans. 11. Should the property be sold or otherwise come under different ownership, any future owners or assignees shall be notified of the conditions of this approval by either the current business owner, property owner or the leasing agent. 12. No outside paging system shall be utilized in conjunction with this establishment. 13. All trash shall be stored within the building or within dumpsters stored in the trash enclosure (three walls and a self-latching gate) or otherwise screened from view of neighboring properties, except when placed for pick-up by refuse collection agencies. The trash enclosure shall have a decorative solid roof for aesthetic and screening purposes. 14. Trash receptacles for patrons shall be conveniently located both inside and outside of the establishment, however, not located on or within any public property or right-of- way. 15. The exterior of the business shall be maintained free of litter and graffiti at all times. The owner or operator shall provide for daily removal of trash, litter debris and graffiti from the premises and on all abutting sidewalks within 20 feet of the premises. 16. The applicant shall ensure that the trash dumpsters and/or receptacles are maintained to control odors. This may include the provision of either fully self-contained dumpsters or periodic steam cleaning of the dumpsters, if deemed necessary by the Planning Division. Cleaning and maintenance of trash dumpsters shall be done in compliance with the provisions of Title 14, including all future amendments (including Water Quality related requirements). 17. Deliveries and refuse collection for the facility shall be prohibited between the hours of 10:00 p.m. and 7:00 a.m., on weekdays and Saturdays and between the hours of 10:00 p.m. and 9:00 a.m. on Sundays and Federal holidays, unless otherwise approved by the Director of Community Development, and may require an amendment to this Minor Use Permit. 18. Storage outside of the building, in the front, or at the rear of the property shall be prohibited, with the exception of the required trash container enclosure. 19. A Special Events Permit is required for any event or promotional activity outside the normal operational characteristics of the approved use, as conditioned, or that would attract large crowds, involve the sale of alcoholic beverages, include any form of on- site media broadcast, or any other activities as specified in the Newport Beach Municipal Code to require such permit. 05-26-2016 2� Zoning Administrator Resolution No. ZA2016-### Page 7 of 7 20. This approval shall expire and become void unless exercised within 24 months from the actual date of review authority approval, except where an extension of time is approved in compliance with the provisions of Title 20 Planning and Zoning of the Newport Beach Municipal Code. 21. To the fullest extent permitted by law, applicant shall indemnify, defend and hold harmless City, its City Council, its boards and commissions, officials, officers, employees, and agents from and against any and all claims, demands, obligations, damages, actions, causes of action, suits, losses, judgments, fines, penalties, liabilities, costs and expenses (including without limitation, attorney's fees, disbursements and court costs) of every kind and nature whatsoever which may arise from or in any manner relate (directly or indirectly) to City's approval of Vacancy Coffee Bar including, but not limited to, Minor Use Permit No. UP2016-034 (PA2016-136). This indemnification shall include, but not be limited to, damages awarded against the City, if any, costs of suit, attorneys' fees, and other expenses incurred in connection with such claim, action, causes of action, suit or proceeding whether incurred by applicant, City, and/or the parties initiating or bringing such proceeding. The applicant shall indemnify the City for all of City's costs, attorneys' fees, and damages which City incurs in enforcing the indemnification provisions set forth in this condition. The applicant shall pay to the City upon demand any amount owed to the City pursuant to the indemnification requirements prescribed in this condition. Public Works 22. Sewer clean-outs shall be installed on all existing sewer laterals. 05-26-2016 22 Attachment No. ZA 2 Vicinity Map 12 VICINITY MAP t Y 3 Minor Use Permit No. UP2016-034 PA2016-136 6480 W. Coast Highway 23 Attachment No. ZA 3 Project Plans 14 PA2016-136 REVISIONS BY V I C I N I T Y M A P S H E E T I N D E X �� \ \ NEWPORT SHORES A0.0 DATA, SITE/BUIDLING PLAN, PROJECT DESCRIPTION \ R\ COMMUNITY ASSOC. \ A.01 GENERAL NOTES A-1 FLOOR PLAN - EXISTING & DEMO A-2 FLOOR PLAN - PROPOSED & FINISH A-3 INTERIOR ELEVATIONS D-1 DETAILS D-2 DETAILS VACANCY COFFEE BARz Rr Rso \ R� U GENERAL NOTES 6480 WEST COAST HFro ry� 1. ALL WORK SHALL COMPLY WITH THE FOLLOWING CODES INCLUDING LOCAL ORDINANCES: NEWPORT BEACH , CA . 9 P 2013 CALIFORNIA BUILDING CODE (CBC) 2013 CALIFORNIA MECHANICAL CODE (CMC) h y 2013 CALIFORNIA PLUMBING CODE (CPC) ��P? 2013 CALIFORNIA ELECTRICAL CODE (CEC) F. e FP v 2013 CALIFORNIA GREEN BUILDING STANDARDS CODE (CGBS) wes� A `l Pon q 2013 CALIFORNIA ENERGY EFFICIENCY STANDARD (CEES) P.,,k CITY OF SANTA MONICA LOCAL ORDINANCES TENANT IMPROVEMENT SUITES ` s o`y c, 2. CONTRACTOR SHALL VERIFY ALL DIMENSION, CONDITIONS ON THE JOB SITE BEFORE STARTING THE JOB. 3. ALL WORK SHALL CONFORM TO THE 2013 CBC OR THE LATEST EDITION OF THE LOCAL CITY BUILDING CODE AND ALL OTHER APPLICABLE CODES. JOB SITE 4. CONCRETE STRENGTH: 2500 P.S.I. 0 28 DAYS USE TYPE V CONCRETE, STD, FTG. CONCRETE MIX`. 1 PT. CEMENT, 3 PTS. NORTH SAND, 4 PTS. MAX. 1° ROCK AND MAX 8-1/2 GALS. OF WATER PER SACK OF CEMENT. 5. LUMBER: USE DOUGLAS FIR. LARCH NO. 1 OR BETTER UNLESS OTHERWISE NOTED ON FRAMING PLANS, NO. 2 FOR STRUCTURE BEAMS. P R O J E C T D A T A STAMP I I EXISTING EXISTING EXISTING SINGLE FAMILY SINGLE FAMILY SINGLE FAMILY JOB ADDRESS: RESIDENCE RESIDENCE RESIDENCE (MULTI STORIES) (MULTI STORIES) (MULTI STORIES) 6480 WEST COAST HIGHWAY NEWPORT BEACH, CA 92663 (E)CMU WALL LEGAL: TRACT 709 BILK. 4 LOT 13 APN: 045-083-15 (E) PARKING (3 PARKING) ZONING: GENERAL COMMERCIAL YEAR BUILT: 1956 20'-0' 60'-2' 4'-10' EXSITING SHOW ROOM/MAILORDER SUITE - NO-WORK PROPOSED T.I. CONST. TYPE: V-NR mN V J EXISTING EXISTING OCCUPANCY GROUP: B (CBC2013, 304.1 ) SINGLE FAMILY SINGLE FAMILY DESC. OF USE: GEN. COMMERCIAL RESIDENCE RESIDENCE U (MULTI STORIES) (E) MAIN (MULTI STORIES) (EXISTING MAIL ORDER, SHOW ROOM - COMMERCIAL ELEC. WHOLESALE) s (NO CHANGE TO EXISTING) U II II I II II I � LOT SIZE: 3,819 S.F. m (E) PARKING II II TOTAL BUILDING 1 ,835 SF PROPOSED � a (�� EXISTING MAIL ORDER, TENANT IMPROVEMENT o EXIST: 1 -STORY p SHOWROOM COFFEE BAR co HEIGHT; 12' +/ ( NO CHANGE) SUITES(2) (EXISTG. 2 SUITES) C ALLEY I I I I I I ll__l z II II I P L PROPOSED SUB-LEASE PARTIAL SUITES FOR COFFEE W (E)CMU WALL (E)CMU WALL BAR, APPROX. 515 S.F. ACC.PATH ACC.PATH , o SIDEWALK I O P/ - U = WEST COAST HIGHWAY \ r o UU z SITE / BUILDING PLAN :�(nN SCALE: 1/8"=l '—O" U U BUILDING AND SPACE INFORMATION: OCCUPANT LOAD: FOR PROPOSED SPACED Q U TOTAL PARKING AVAILABLE = 5 SPACES(3 SIDE STREET,3 AT REAR FOR TENANTS) PER CBC TABLE 1004.1.2 COMMERCIAL: 1,835/100 = 18.35 OCC. DRAWN BUILDING FLOOR AREA= T.I.515 S.F. ;515/200 =2.58 OCC (FOR THE COFFEE BAR) JRA/LBA 1,835 SF 300 = 6 REQUIRED DATE TOTAL 18 OCC.LOAD MAX. 05-04-16 EXIT REQUIRED 18xO.3"=5.4' <T MIN. (1 EXIT REQ. PER CBC 1005.1) SCALE PROVIDING 4 EXITS AS NOTED PLUMBING COUNT; 9 M, 9 F (PER CPC 422) TITLE PROVIDING 1-UNISEXTOILETROOMS-SINGLE OCCUPANCY. COVER 1-WC , 1-LAV SHEET EXISTING RESTROOMS NON-ADA COMPLIANCE EACH 1-WC&1 LAV UNISEX. SHEET CODE REQUIRE; 1 WC-MALE 1 LAV-MALE A O ♦ O 2 WC-FEMALE 1 LAV-FEMALE //�\ 15 PA2016-136 REVISIONS BY DEMO GENERAL NOTES DEMO KEYNOTES 16'-3" 4'-6" 4'-0" 6'-11" LEAVE SPRINKLERS INTACT AS-IS (ONLY DURING DEMOLITION).ALL FIRE LIFEO REMOVE INTERIOR TENANT NON LOAD BEARING WALLS AND ASSOCIATED SAFETY EQUIPMENT SHALL BE LEFT IN PLACE.IF A STRUCTURE HOLDING A DEVICE ELECTRICAL,TELE,J-BOX. REMOVE ALL WIRING BACK TO ELECTRICAL SUB PANELS. IS REMOVED,THE CONTRACTOR SHALL SUPPORT THE FIRE LIFE SAFETY DEVICE IN CONTRACTORS TO REMOVE EXISTING DOORS AND FRAMES. A MANNER THAT DOES NOT IMPAIR ITS FUNCTION IN ANY WAY. REMOVE ALL DATA TELE CABLING IN CEILING BACK TO ORIGINAL DEMARK. O REMOVE ALL FLOORS FLOOR COVERING C EAN OF ALLADHSPACE. ADHESIVE, PAD ETC.TO SMOOTH FINISH AND BROOM (UNLESS OTHERWISE INSTRUCTED) CLEAN. ABANDON PLUMBING LINES AND DRAINS TO BE REMOVED BACK TO POINT OF O REMOVE EXISTING WALL FINISHES (CERAMIC TILES, MIRRORS AND TRIMS. 10 ELECT MAIN ORIGINATION AS REQUIRED FOR NEW TENANTS BUILD-OUT. SKIM COAT TENANT WALLS OR REPLACE GYP. BOARD AS NEEDED. PREPARED n Z FOR NEW FINISH. S AFTER DEMOLITION THE SPACE SHOULD BE LEFT IN A CLEAN AND BROOM SWEPT 0 v r CONDITION. ® REMOVE EXISTING PLUMBING FIXTURES. ZZ INTENT OF THE DRAWING IS TO SHOW EXISTING BUILDING CONDITIONS WITH 5REMOVE ALL LIGHTING IN CEILINGS, SOFFIT AND AT T-BAR CLINGS.VERIFY IF ILI Q L, INFORMATION DEVELOPED FROM AVAILABLE DOCUMENTS.CONTRACTOR SHALL O EXISTING J-BOX CAN BE USE WITH NEW PLAN. MAKE A DETAILED SURVEY OF EXISTING CONDITIONS PERTAINING TO THE WORK BEFORE COMMENCING DEMOLITION.THE CONTRACTOR SHALL REPORT O REMOVE ALL CEILING REGISTERS AND DUCTS TO REMAIN.CLEAN ALL EXPOSED DESIGNER DISCREPANCIES BETWEEN DRAWINGS AND ACTUAL FIELD CONDITIONS TO THE 6 DUCTS AND PREP FOR NEW REGISTERS PER NEW PLAN. J. ARCHE ARCHITECT. I I I I 5543 Dunrobin Ave MAINTAIN FULLY CHARGED FIRE EXTINGUISHER READILY AVAILABLE DURING ALL 7 RIMPAQVIR EXISTING In Lakewood, CA 90713 DEMOLITION OPERATIONS. ® EXISTING STOREFRONT TO BE CLEAN THROUGHOUT AND REPAIR AS NEEDED 563-533-3154 ALL REMOVED MATERIAL OTHER THAN ITEMS TO BE SALVAGED OR REUSED SHALL REMOVE AND RELOCATE EXISTING ELECTRICAL SUB PANELS ALL CIRCUIT TO BECOME CONTRACTORS PROPERTY U.N.O.,AND SHALL BE REMOVED FROM O REMAIN, SEE NEW PLAN FOR LOCATION. OWNER'S PROPERTY. CLEAN UP AND DISPOSE OF DEBRIS PROMPTLY AND o CONTINUOUSLY AS THE WORK PROGRESSES.SECURE AND PAY FOR REQUIRED REMOVE EXISTING DRINKING FOUNTAIN WITH ALL ACCESSORIES CAP BEHIND OFFICE o HAULING PERMITS, PAY DUMPING FEES AND CHARGES. 1 WALL. ccu (OPEN AREA) RECEIVING SHIPPING (E) SHOW ROOM M NO( WORK) NO( WORK) NO( WORK) WHERE CONSTRUCTION TO BE REMOVED INTERSECTS CONSTRUCTION TO REMAIN, REMOVE EXISTING PIPE RAILING, PATCH ANCHOR HOLE TO MATCH ADJACENT WORK SHALL INCLUDE OF ALL ATTACHMENT DEVICES (SHOT PINS,ANCHORS, LAB 11 AREA. BOLTS, NAILS, NAILERS, SHIMS, ETC.) 12 EXISTING FLOOR SINK TO REMAIN, CLEAN GRATE. SEE NEW PLAN IF REUSE, IF NOT CAP OFF AND FILL SLAB TO MATCH ADJACENT AREA. I II II 13 REMOVE EXISTING WALK-IN COLLIER. 16'-3" I 1 12'-4" 12'-10" I I 14 REMOVE EXISTING SERVING COUNTER. LEGEND 15 REMOVE ALL BATT INSULATION ABOVE CEILING,TYPICAL. II II II I I EXISTING PARTITION TO REMAIN. STAMP _ _ = EXISTING NON-BEARING PARTITION TO BE REMOVED. T DEMOLITION KEYNOTE. EXISTING DOOR TO REMAIN. EXISTING PLAN nl II \ EXISTING DOOR TO BE REMOVED. SCALE: 1/4" = 1 '-0" I V u i R INDICATES REMOVE. ( n INDICATES EXISTING. CV REMOVE PORTION OF WALL Q FOR NEW WINDOW OPENING, PATCH &FINISH TO MATCH ADJACENT AREA. �4' 2�2� U REMOVE ALL FIXTURES � � W1 ACCESSORIES, EQ. EQ. DOOR &FRAME CD �I < O C II II II II W � II II z II II II II � II II � II II II II o II II s II II � II II U = REMOVE ALL NO WORK CLOTHING H �J DISPLAY (RACKS&TABLES) II II II V o II II II � U II II II II II II II II II II II U o II II II II II Q cp II II II I � DRAWN JRA/LBA DATE 05-04-16 SCALE AS NOTED TITLE SITE PLAN SHEET DEMOLITION PLAN SCALE: 1/4" = 1 '-0" n _ 1 10 PA2016-136 REVISIONS BY 16'-3" DOOR SCHEDULE 4'-6" 4'-0" 2'-0" 2' 01 (E)3'-0"X6'-8" STORE FRONT DOORS, GLASS/ALUM. PULL/PUSH BAR, DEAD BOLT LOCK SET. 2,-6„ 02 3N -8, SELF"W CLOSER. LITE , LEVEL LOCK SET, PRIVATCY LOCK FROM KITCHEN SIDE, o 03 (N)3'-0"X6'-8"WD SOLID CORE, LEVEL LOCK SET, PRIVATCY LOCK, 3-BUTTS, SELF CLOSER. 10 ALL NEW ADA FIXTURES, O W.C., LAV AND GRAB BARS N SEE DETAILS ON D.1 04 01 (E)8'-6"X6'-8" ROLLING DOOR. RESTROOM 1 NO WORK p — 05 (N)4'-0"X3'-2"SLIDING WINDOW. ID] - < FURTURE REFRIG. DESIGNER J. ARCHE 5543 Dunrobin Ave Lakewood, CA 90713 1 1 1 1 ________ 563-533-3154 O EQUIPMENT SCHEDULE 11 11 __=___ TFM GUANffY PF5CFIFfl0N MANOFACTUP� MOOFL FLUMPING COMMFNT ESPRESSO MACHINE LA MARZOCCO GB-5 ELECT. OFFICE o n M 2 I COFFEE MAKER FETCO CBS-21 31 XTS-1 G ELECT. N (OPEN AREA) RECEIVING SHIPPING 003 THERMAL SERVER FETCO L3S-10-1 NO( WORK) NO( WORK) NO( WORK) ADA SEATING 4 I GRINDER 1 MAllER KONY ELECT. 5 I GRINDER 2 MAllER SUPER JOLLY ELECT. u 'o I GRINDER 3 BUNN G1 ELECT. I SANDWICH PRESS WINCO EPG-1 ELECT. 16'-3" 12'-4" 12'-10" 8'-11" F- 7 --zrJ Q 8 I MICROWAVE AMANA RMS10D ELECT. 9 I FRIDGE 1 MARCHIA MDC160 COUNTER TOP DISPLAY 10 I FRIDGE 2 LEADER LB48 UNDER COUNTER PROPOSED J J 11 6O FRIDGE 3 TBD TBD TBD COFFEE BAR II II II II II II II II II STAND TABLE Q ENTR CE O O STAMP I I FINISH SCHEDULE FOOM FLOOFS 6A5F COVF WALL5 CFI ING COMMFNfS 1 1 42" H COUNTER TOP CLIENT AREA CONCRETE SEAL CONCRETE SEAL G.B. PAINT DW SERVICE AREA CONCRETE SEAL CONCRETE SEAL G.B. PAINT DW TOILET CERAMIC TILE CERAMIC TILE CERAMIC TILE PAINT DW PASSAGE CONCRETE SEAL CONCRETE SEAL G.B. PAINT DW I PROPOSAL m SCALE: 1/4" = 1 '-0" N U N 6� Q U 02 02 02 AD R/ / UPJ Q 03 11 W II II 11 L z II II 6 II II � II II � 3 10 � II II q ` OFFICE I I I I r 0, (OPEN AREA) 1 1 RECEIVING 1 1 SHIPPING 5 D ' ` m NO WORK NO WORK NO WORK V O II II II 9 z U II II II o4 = U o II II II II II II II II II II II II U DRAWN JRA/LBA O O DATE 05-04-16 SCALE AS NOTED Ol TITLE 01 SITE PLAN SHEET EQUIPMENT DOOR & WINDOW PLAN SCALE: 1/4" = 1 '-0" N A - 2 PA2016-136 REVISIONS BY 7 8 6 2 3 (N) SLIDING WINDOW (N)WOOD SHELVING (E) R.S. WOOD PLANK WALL (N) SIGNAGE BOARD TBD FIN.TYP. � z S � v � Q � DESIGNER 21 J. ARCHE ® COMP. REGISTER 5543 Dunrobin Ave ® Lakewood, CA 90713 Q0 � �m �� 563-533-3154 O � 0 LO (0 23 O O \ \ \ O O NORTH ELEVATION EAST ELEVATION STAMP SCALE: 3/4" = 1'-0" SCALE: 3/4" = 1'-0" CD 2 9 1 9 5 4 1 7 8 N Q U s v a FROSTED GLASS S_ BACK SPLASH ,�/'� O 4 Q W z rz W LL— LLL 00 o T LO � 4-N 0 0 0 ''19 N IF Uo Qcp SOUTH ELEVATION WEST ELEVATION > SCALE: 3/4" = 1 '-0" SCALE: 3/4" = 1 '-0" u DRAWN JRA/LBA DATE 05-04-16 SCALE AS NOTED TITLE INTERIOR ELEVATION SHEET A - 3 12 PA2016-136 6" REVISIONS BY 1/2" RADIUS (TYP.) -------------------- PLYWOOD, WHERE WHITE IMAGE01 OCCURS (E) 2X4 BRACING 4'-6" ( _ = @ 16" O.C.STUDS ALT. CONN. L _ _ @ 2/-6" _ BLUE BACKGROUND 5/8" GYPSUM BOARD BOTTOM OF (E) TJI B.S. 1/4" THICK ACRYLIC PLASTIC 3 4" 5/8" BUILT-UP WOOD FRAME TO MACTHco z // EXISTING 2-2X TOP PL W/ S 00 16d @ 12" O.C.s. U o / < z /� 0 0 DOOR PER SCHEDULE I g I + DESIGNER d FIRE BLOCKING J. ARCHE 5543 Dunrobin Ave NLakewood, CA 90713 r LINE OF CEILING WHERE 563-533-3154 "2- OCCURS WOOD BLOCKING 5/8" TYPE "X" GYPSUM BOARD W WALL FINISH PER SCHEDULE 6 ACCESSIBLE ENTRANCE SIGN Z 3 WOOD DOOR JAMB/ HEAD SIM g 2X CONT. BOT. PLATE W/ SCALE: N.T.S. w SCALE: 3"=1 '-O" 3 SIMPSON PHN ANCHORS @ 32" O.C. ENLARGE TOILET PLAN ESR-2138 SCALE: 1/2" = 1 '-0" ALAN (E) CONC. SLAB 1/4" THICK 10" ACRYLIC PLASTIC SECTION COLOR AND CONTRAST SHALL BE DIFFERENT FROM DOOR MOUNTED COLOR AND CONTRAST OF WALL SIGNAGE C STAMP EXIT co � WALL MOUNTED SIGNAGE 8 6„ zI I W.R. GYPSUM BOARD PLAN L- wI UNISEX oI ,, TILE COVE BASE MAX. DEFLECTION: L/360 DESIGN LOAD: 7 PSFLO M OF DOOR W.P. MEMBRANE ` J 12'$ o z STUD a 1/4" THICK LLJ D / — 0a 0 0 g ~ Vl ACRYLIC PLASTIC o N ¢ Q � X REMARKS N NOTE: WALL MOUNTED SIGNAGE TO Q w ag 0 � m BE LOCATED ON LATCH SIDE OF / - co Q z V J DOOR CLEAR OF DOOR-SWING TILE OVER a 0 THIN SET NOTE MORTAR BED 2 X 4 16" YGA.: WP 3510 Q THESE ARE MINIMUM CORRESPONDING GRADE 2 BRAILLE INDICATION PER T-24 SEC. STANDARDS FOR WP 3514 ( 1 117B.5.2 BRAILLE SYMBOLS: CONTRACTED GRADE 2 BRAILLE SHALL BE 5'-0" A.F_F. THESE SIGNS. �J USED WHEREVER BRAILLE SYMBOLS ARE SPECIFICALLY REQUIRED IN SIGNS ARE REQUIRED OTHER PORTIONS OF THESE STANDARDS. DOTS SHALL BE 1/10" (2.54 TO BE MOUNTED NOTE: S mm) ON CENTERS IN EACH CELL WITH 2/10" (5.08 mm) SPACE CENTERED ON THE EXTERIOR SIDE OF IN ADDITION TO DOOR MOUNTED SIGNAGE, RESTROOMS ARE U BETWEEN CELLS. DOTS SHALL BE RAISED A MINIMUM OF 1/40" (0.635 TOILET DOOR. REQUIRED TO PROVIDE SIGNAGE ON THE LATCH SIDE OF mm) ABOVE THE BACKGROUND. UNISEX THE DOOR. 11 EXIT SIGN X 9 TOILET DOOR SIGNAGE 7 TOILET ROOM SIGNAGE 4 BASE m 0 1 WODD PARTITION Q 4� SCALE: 1 -1/2" = 1 '-0" w SCALE: 1 -1/2" = 1 '-0" SCALE: 1/2"=1 '-0" SCALE: 3"=1 '-O" j a S- a d o SCALE: 1 1/2"=l '-O" 3 O C W W COUNTERTOP 11�1 z I� 3/4" EXT. PLYWD 18" MIN. CLR. M Os MIRROR i i CD FIRE EXTINGUISHER CABINET -I - SOAP DISPENSER HOT WATER & DRAIN U O LINE TO BE INSULATED z PER TITLE 24 < REQUIREMENT & SECTION CONTROLS TO BE OPERABLE WITH 6' N 1504 U.P.C. ONE HAND AND MOUNTED ON THE WIDE SIDE OF TOILET AREAS, NO MORE THAN 44' ABOVE O O O THE FLOOR. THE FORCE REQUIRED ADJUSTABLE V E TO ACTIVATE CONTROLS TO BE NO R V GREATER THAN 5 LBS. — — —� �HELF— LF — — — — _ (� FLUSH VALVE CONTROLS N \f` CAC T-24-PARTS A FIN. T.B.D. CL VARIES SEC 5 1502 ( n FIRE ALARM PULL BOX N 24" 24" 15" NOTE: WALL MOUNTED SIGNAGE TO TRAVEL DISTANCE NOT DRAWN GRAB BAR 15' UNISEX M BE LOCATED ON LATCH SIDE OF X TO EXCEED 200 FT. JRA/LBA GRAB BAR DOOR CLEAR OF DOOR-SWING z — GRAB BAR o � PROVIDE 6" DATE 18" RECESSED CORRESPONDING GRADE 2 BRAILLE INDICATION PER T-24 SEC. o BASE, 05 04SCALE16 m TOILET 1178.5.2 BRAILLE SYMBOLS: CONTRACTED GRADE 2 BRAILLE SHALL BE o _ PAPER SWING-UP USED WHEREVER BRAILLE SYMBOLS ARE SPECIFICALLY REQUIRED IN AS NOTED N N p77 DISPENSER N — GRAB BAR WITH OTHER PORTIONS OF THESE STANDARDS. DOTS SHALL BE 1/10" (2.54 TITLE TOILET TISSUE mm) ON CENTERS IN EACH CELL WITH 2/10" (5.08 mm) SPACE /� 12 SPINDLE BETWEEN CELLS. DOTS SHALL BE RAISED A MINIMUM OF 1/40" (0.635 B NFPA 728 - 3-1 .1 .3(b) 3„ DETAILS B C mm) ABOVE THE BACKGROUND. SHEET 1 Q PLUMBING FIXTURE ELEVATIONS m $ TOILET WALL SIGNAGE 5 TYPICAL FIRE ACCESSORIES Z BASECABINET SCALE: 1/4" = 1 '-0" SCALE: 1 -1/2" = 1 '-0" SCALE: 1/4" = 1 '-0" 0 SCALE: 1 1/2" = 1 '-0" m a a a D - 1