Loading...
HomeMy WebLinkAbout01_Bengtson Residence Coastal Development Permit_PA2017-058COMMUNITY DEVELOPMENT DEPARTMENT PLANNING DIVISION 100 Civic Center Drive, P.O. Box 1768, Newport Beach, CA 92658-8915 949-644-3200 www.newportbeachca.gov CITY OF NEWPORT BEACH ZONING ADMINISTRATOR STAFF REPORT September 28, 2017 Agenda Item No. 1 SUBJECT: Bengtson Residence CDP (PA2017-058) SITE LOCATION: 111 8th Street Coastal Development Permit No. CD2017-024 APPLICANT: Chris Bengtson OWNER: Chris Bengtson PLANNER: Gregg Ramirez, Senior Planner 949-644-3219, gramlrez(@newportbeachca.goy GENERAL PLAN/ZONING DISTRICT • General Plan: RS -D (Single -Unit Residential Detached) • Zoning District: R-1 (Single -Unit Residential) • Coastal Land Use Category: RSD -D (Single -Unit Residential Detached — (10.0 — 19.9 DU/AC)) Coastal Zoning District: R-1 (Single -Unit Residential) PROJECT SUMMARY A Coastal Development Permit (CDP) to demolish a one-story, single-family residence and garage and construct a new three-story, 3,380 -square -foot, single-family residence and attached garage. The project also includes hardscape, drainage, and landscaping. The project complies with all applicable development standards. No deviations are requested. RECOMMENDATION 1) Conduct a public hearing; 2) Find this project exempt from the California Environmental Quality Act (CEQA) pursuant to Section 15303 under Class 3 (New Construction or Conversion of Small Structures) of the CEQA Guidelines, because it has no potential to have a significant effect on the environment; and 3) Adopt Draft Zoning Administrator Resolution No. _ approving Coastal Development Permit No. CD2017-024 (Attachment No. ZA 1). 1 Bengtson Residence CDP Zoning Administrator, September 28, 2017 Page 2 DISCUSSION Land Use and Development Standards • The subject property is located in the R-1 Coastal Zoning District, which provides for single -unit residential development and is consistent with the City's Coastal Land Use Plan, General Plan, and Zoning Code. A coastal development permit is required and the property is not eligible for a Waiver for De Minimis Development because the property is located in the Appeal Area. The property consists of a legal lot developed with a single-family residence. The neighborhood is developed with a mix of one-, two-, and three-story single-family residences. The proposed design, bulk, and scale of the development is consistent with the existing neighborhood pattern of development and expected future development because the project complies with all development standards. The proposed single-family dwelling and accessory structures conform to all applicable development standards, including floor area limit, setbacks, height, and off-street parking as illustrated in Table 1 below. Hazards • The finish floor elevation of the proposed dwelling is 10.50 feet (NAVD 88), which complies with the minimum 9.00 feet (NAVD88) elevation required by the Zoning Code and Local Coastal Program. The property is located in an area known for the potential of seismic activity and liquefaction. All projects are required to comply with the California Building Code (CBC) and Building Division standards and policies. Geotechnical investigations specifically addressing liquefaction are required to be reviewed and approved prior TmpIC. 01/17/17 2 Table 7 — Development Standards Development Standard Standard Proposed Setbacks min. Front 10 feet 10 feet Sides 4 feet 4 feet Rear 5 feet (alley) 2.5 feet second floor 5 feet 2.5 feet Allowable Floor Area 3,912 square feet 3,380 square feet Allowable 3rd Floor Area 293 square feet 291 square feet Open Space 293 square feet 474 square feet Parkin 2 -car garage 2 -car aaraae Height 24 feet flat roof 29 feet sloped roof 24 feet flat roof 29 feet sloped roof Hazards • The finish floor elevation of the proposed dwelling is 10.50 feet (NAVD 88), which complies with the minimum 9.00 feet (NAVD88) elevation required by the Zoning Code and Local Coastal Program. The property is located in an area known for the potential of seismic activity and liquefaction. All projects are required to comply with the California Building Code (CBC) and Building Division standards and policies. Geotechnical investigations specifically addressing liquefaction are required to be reviewed and approved prior TmpIC. 01/17/17 2 Bengtson Residence CDP Zoning Administrator, September 28, 2017 Page 3 to the issuance of building permits. Permit issuance is also contingent on the inclusion of design mitigation identified in the investigations. Construction plans are reviewed for compliance with approved investigations and CBC prior to building permit issuance. Water Quality The property is not located within 100 feet of coastal waters. Project design addresses water quality with a construction erosion control plan and a post construction drainage system that includes drainage and percolation features designed to retain dry weather and minor rain event run-off on-site. Any water not retained on-site is directed to the City's storm drain system. Public Access The project site is located between the nearest public road and the sea or shoreline; however, the project will not affect the public's ability to gain access to, use, and/or view the coast and nearby recreational facilities because: 1. Vertical access to the beach and the West Ocean Front boardwalk is available at the terminus of 8th Street. The proposed project will not alter exiting public access 2. The proposed project is located entirely on private property and there will be no reduction in on -street parking spaces. ENVIRONMENTAL REVIEW This project is exempt from the California Environmental Quality Act (CEQA) pursuant to Section 15303 under Class 3 (New Construction or Conversion of Small Structures) of the CEQA Guidelines, California Code of Regulations, Title 14, Chapter 3, because it has no potential to have a significant effect on the environment. Class 3 exempts the demolition of up to three single-family residences and additions of up to 10,000 square feet to existing structures. The proposed project consists of the demolition of one single-family residence and the construction of a new 2,919 -square - foot single-family residence and attached 461 -square -foot 2 -car garage. PUBLIC NOTICE Notice of this public hearing was published in the Daily Pilot, mailed to all owners and residential occupants of property within 300 feet of the boundaries of the site (excluding intervening rights-of-way and waterways), including the applicant, and posted on the subject property at least 10 days before the scheduled hearing, consistent with the Tmpl[: 01/17/17 3 Bengtson Residence CDP Zoning Administrator, September 28, 2017 Page 4 provisions of the Municipal Code. Additionally, the item appeared on the agenda for this meeting, which was posted at City Hall and on the City website. APPEAL PERIOD: An appeal or call for review may be filed with the Director of Community Development within 14 days following the date of action. For additional information on filing an appeal, contact the Planning Division at 949-644-3200. Prepared by: -Ai�z6e� Gregg Rgirqfirez Senior Planner BW/gbr Attachments: ZA 1 Draft Resolution ZA 2 Vicinity Map ZA 3 Project Plans Tmpl[: 01/17/17 Attachment No. ZA 1 Draft Resolution 5 RESOLUTION NO. ZA2017-### A RESOLUTION OF THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH APPROVING COASTAL DEVELOPMENT PERMIT NO. CD2017-024 TO DEMOLISH AN EXISTING SINGLE-FAMILY RESIDENCE AND CONSTRUCT A NEW SINGLE-FAMILY RESIDENCE AND ATTACHED 2 -CAR GARAGE LOCATED AT 111 8TH STREET (PA2017-058) THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH HEREBY FINDS AS FOLLOWS: SECTION 1. STATEMENT OF FACTS. 1. An application was filed by Chris Bengtson, Property Owner, with respect to property located at 111 8th Street, and legally described as Lot 1 of Block 7 of the East Newport Tract, requesting approval of a Coastal Development Permit. 2. The applicant proposes to demolish a one-story, single-family residence and garage and construct a new three-story, 3,380-square—foot, single-family residence and attached garage. The project also includes hardscape, drainage, and landscaping. The project complies with all applicable development standards. No deviations are requested. 3. The subject property is located within the R-1 (Single -Unit Residential) Zoning District and the General Plan Land Use Element category is RS -D (Single -Unit Residential Detached). 4. The subject properties are located within the coastal zone. The Coastal Zoning District is R-1 (Single -Unit Residential) and the Coastal Land Use Plan category is RSD -D (Single - Unit Residential Detached — 10.0-19.9 DU/AC). 5. A public hearing was held on September 28, 2017, in the Corona del Mar Conference Room (Bay E-1 st Floor) at 100 Civic Center Drive, Newport Beach. A notice of time, place and purpose of the meeting was given in accordance with the Newport Beach Municipal Code. Evidence, both written and oral, was presented to, and considered by, the Zoning Administrator at this meeting. SECTION 2. CALIFORNIA ENVIRONMENTAL QUALITY ACT DETERMINATION. This project is categorically exempt pursuant to Title 14 of the California Code of Regulations Section 15303, Article 19 of Chapter 3, Guidelines for Implementation of the California Environmental Quality Act (CEQA) under Class 3 (New Construction or Conversion of Small Structures). 2. Class 3 exempts the demolition of up to three single-family residences and additions of up to 10,000 square feet to existing structures. The proposed project consists of the demolition of one single-family residence and the construction of a new 2,919 -square - foot, single-family residence and 461 -square -foot, 2 -car garage. N Zoning Administrator Resolution No. ZA2017-### Pape 2 of 7 SECTION 3. REQUIRED FINDINGS. In accordance with Section 21.52.015 (Coastal Development Permits, Findings and Decision) of the Newport Beach Municipal Code, the following findings and facts in support of such findings are set forth: Finding: A. Conforms to all applicable sections of the certified Local Coastal Program. Facts in Support of Finding: The proposed development complies with applicable residential development standards including, but not limited to, floor area limitation, setbacks, height, and parking. a. The maximum floor area limitation is 3,912 square feet and the proposed floor area is 3,380 square feet. b. The proposed development provides the minimum required setbacks, which are 10 feet along the front property line, 4 feet along each side property line, and 5 feet along the rear property line abutting the alley. C. The highest guardrail is no more than 24 feet from established grade (9.805 feet NAVD88) and the highest ridge is no more than 29 feet from established grade, which complies with the maximum height requirements. The project includes garage parking for a total of two vehicles, complying with the minimum two -car garage parking requirement for single-family residences with less than 4,000 square feet of habitable floor area. 2. The neighborhood is predominantly developed with one-, two-, and three-story single- family residences. The proposed design, bulk, and scale of the development is consistent with the existing neighborhood pattern of development and expected future development. 3. The proposed development is not located on the shoreline and is over 100 feet from the nearest beach. The proposed finished floor is 10.5 feet (NAVD 88) which is higher than the 9.00 feet (NAVD 88) standard. Impacts from wave run-up and sea -level rise are not anticipated. 4. The property is located in an area known for the potential of seismic activity and liquefaction. All projects are required to comply with the California Building Code (CBC) and Building Division standards and policies. Geotechnical investigations specifically addressing liquefaction are required to be reviewed and approved prior to the issuance of building permits. Permit issuance is also contingent on the inclusion of design mitigation identified in the investigations. Construction plans are reviewed for compliance with approved investigations and CBC prior to building permit issuance. os-az-zon Zoning Administrator Resolution No. ZA2017-### Pape 3 of 7 5. Project design addresses water quality with a construction erosion control plan and a post construction drainage system that includes drainage and percolation features designed to retain dry weather and minor rain even run-off on-site. Any water not retained on-site is directed to the City's storm drain system. 6. Proposed landscaping complies with the Implementation Plan Section 21.30.075. Final landscape plans will be reviewed to verify invasive species are not planted. 7. The property is not located near designated public view points or coastal view roads and will not impact public coastal views. Finding: B. Conforms with the public access and public recreation policies of Chapter 3 of the Coastal Act if the project is located between the nearest public road and the sea or shoreline of any body of water located within the coastal zone. Fact in Support of Finding: The project site is located between the nearest public road and the sea or shoreline; however, the project will not affect the public's ability to gain access to, use, and/or view the coast and nearby recreational facilities because: Vertical access to the beach, water and West Ocean Front Boardwalk is available at the terminus of 8th Street. The proposed project will not alter exiting public access 2. The proposed project is located entirely on private property and there will be no reduction in on -street parking spaces. SECTION 4. DECISION. NOW, THEREFORE, BE IT RESOLVED: The Zoning Administrator of the City of Newport Beach hereby approves Coastal Development Permit No. CD2017-024, subject to the conditions set forth in Exhibit "A," which is attached hereto and incorporated by reference. 2. This action shall become final and effective 14 days following the date this Resolution was adopted unless within such time an appeal or call for review is filed with the Community Development Director in accordance with the provisions of Title 21 Local Coastal Implementation Plan, of the Newport Beach Municipal Code. Final action taken by the City may be appealed to the Coastal Commission in compliance with Section 21.64.035 of the City's certified LCP and Title 14 California Code of Regulations, Sections 13111 through 13120, and Section 30603 of the Coastal Act. 06-02-2017 g Zoning Administrator Resolution No. ZA2017-### Paqe 4 of 7 PASSED, APPROVED, AND ADOPTED THIS 28TH DAY OF SEPTEMBER, 2017. Patrick J. Alford, Zoning Administrator 06-02-2017 9 Zoning Administrator Resolution No. ZA2017-### Pape 5 of 7 EXHIBIT "A" CONDITIONS OF APPROVAL (project specific conditions are italicized) 1. The development shall be in substantial conformance with the approved site plan, floor plans, and building elevations stamped and dated with the date of this approval (except as modified by applicable conditions of approval). 2. Revisions to the approved plans may require an amendment to this Coastal Development Permit or the processing of a new Coastal Development Permit. 3. Coastal Development Permit No. CD2017-024 shall expire unless exercised within 24 months from the date of approval as specified in Section 21.54.060 (Time Limits and Extensions) of the Newport Beach Municipal Code, unless an extension is otherwise granted. 4. The project is subject to all applicable City ordinances, policies, and standards, unless specifically waived or modified by the conditions of approval. 5. This Coastal Development Permit may be modified or revoked by the Zoning Administrator if determined that the proposed uses or conditions under which it is being operated or maintained is detrimental to the public health, welfare or materially injurious to property or improvement in the vicinity or if the property is operated or maintained so as to constitute a public nuisance. 6. Prior to the issuance of building permits, a copy of the Resolution, including conditions of approval Exhibit "A" shall be incorporated into the Building Division and field sets of plans. 7. Prior to the issuance of a building permit, the applicant shall pay any unpaid administrative costs associated with the processing of this application to the Planning Division. 8. Prior to the issuance of building permits, the applicant shall submit to the Planning Division an additional copy of the approved architectural plans for inclusion in the Coastal Development file. The plans shall be identical to those approved by all City departments for building permit issuance. The approved copy shall include architectural sheets only and shall be reduced in size to 11 inches by 17 inches. The plans shall accurately depict the elements approved by this Coastal Development Permit. 9. Prior to the issuance of building permits, the applicant shall submit a final construction erosion control plan. The plan shall be subject to the review and approval by the Building Division. 06-02-2017 10 Zoning Administrator Resolution No. ZA2017-### Pape 6 of 7 10. Prior to the issuance of building permits, the applicant shall submit a final drainage and grading plan. The plan shall be subject to the review and approval by the Building Division. 11. Prior to the issuance of building permits, the applicant shall submit a final landscape and irrigation plan consistent with Implementation Plan Section 21.30.075. The plans shall be approved by the Planning Division. 12. All landscape materials and irrigation systems shall be maintained in accordance with the approved landscape plan. All landscaped areas shall be maintained in a healthy and growing condition and shall receive regular pruning, fertilizing, mowing and trimming. All landscaped areas shall be kept free of weeds and debris. All irrigation systems shall be kept operable, including adjustments, replacements, repairs, and cleaning as a part of regular maintenance. 13. Should the property be sold or otherwise come under different ownership, any future owners or assignees shall be notified of the conditions of this approval by either the current business owner, property owner or the leasing agent. 14. Debris from demolition shall be removed from work areas each day and removed from the project site within 24 hours of the completion of the project. Stock piles and construction materials shall be covered, enclosed on all sites, not stored in contact with the soil, and located as far away as possible from drain inlets and any waterway. 15. Trash and debris shall be disposed in proper trash and recycling receptacles at the end of each construction day. Solid waste, including excess concrete, shall be disposed in adequate disposal facilities at a legal disposal site or recycled at a recycling facility. 16. The applicant shall comply with all federal, state, and local laws. Material violation of any of those laws in connection with the use may be cause for revocation of this Coastal Development Permit. 17. No demolition or construction materials, equipment debris, or waste, shall be placed or stored in a location that would enter sensitive habitat, receiving waters, or a storm drain, or result in impacts to environmentally sensitive habitat areas, streams, wetland or their buffers. 18. Best Management Practices (BMPs) and Good Housekeeping Practices (GNPs) shall be implemented prior to and throughout the duration of construction activity. 19. The discharge of any hazardous materials into storm sewer systems or receiving waters shall be prohibited. Machinery and equipment shall be maintained and washed in confined areas specifically designed to control runoff. A designated fueling and vehicle maintenance area with appropriate berms and protection to prevent spillage shall be provided as far away from storm drain systems or receiving waters as possible. 06-02-2017 11 Zoning Administrator Resolution No. ZA2017-### Pape 7 of 7 20. To the fullest extent permitted by law, applicant shall indemnify, defend and hold harmless City, its City Council, its boards and commissions, officials, officers, employees, and agents from and against any and all claims, demands, obligations, damages, actions, causes of action, suits, losses, judgments, fines, penalties, liabilities, costs and expenses (including without limitation, attorney's fees, disbursements and court costs) of every kind and nature whatsoever which may arise from or in any manner relate (directly or indirectly) to City's approval of Bengtson Residence Coastal Development Permit including, but not limited to, Coastal Development Permit No. CD2017-024 (PA2017-058). This indemnification shall include, but not be limited to, damages awarded against the City, if any, costs of suit, attomeys' fees, and other expenses incurred in connection with such claim, action, causes of action, suit or proceeding whether incurred by applicant, City, and/or the parties initiating or bringing such proceeding. The applicant shall indemnify the City for all of City's costs, attomeys' fees, and damages, which City incurs in enforcing the indemnification provisions set forth in this condition. The applicant shall pay to the City upon demand any amount owed to the City pursuant to the indemnification requirements prescribed in this condition. NZ k- 06-02-2017 12 Attachment No. ZA 2 Vicinity Map 13 VICINITY MAP o��Ary rq�H W Coastal Development Permit No. CD2017-024 (PA2017-058) 111 8t" Street :L4 Attachment No. ZA 3 Project Plans 15 ,, i _ 04 CITY OF NEWPORT BEACH u i COAUdUNM DEVELOPMENT DEPARTMENT '- I - QQ{t-yµty\P BUILDING DIVI3IONSITE 3,039 S.F. SITE PLAN & PROJECT DATA 100 Civic Center Drive I P.O. Box 17681 Newport Bei, CA 926565915 NOTE: ! www, newoortbeachcaAov I (849) 644.3200 1. POOLS, SPAS, WALLS, FENCES, PATIO COVERS AND OTHER BUILDABLE AREA 1,956 S.F. 2 SURVEY / GRADING --PLAN _ .. . FLOOR AREA LIMIT (2 x 1,956 S.F.) 3,912 S.F. 3 LOWER LEVEL FLOOR PLAN Structural Observation Re rt FREESTANDING STRUCTURES REQUIRE SEPARATE REVIEWS AND 3RD FL. MAX S.F. (15%x 1,956 S.F.) 293.4 S.F. 4 MIDDLE LEVEL FLOOR PLAN PERMITS. VEL FLOOR PLAN __ _ ...... ....... CNB bwpectw Name: cNePemar- aaw0reown« PI} owners MffM Aedes (Ifda(ererntrom sft); srelepn * 735-2(as3 CNS Plan check#. Fuff Neme of 5huctwWOhserver o): lk1L iCAii SOE4na Aed . FNWRR'R.G7MA4VCOM SOT f: 119. ciNA2 0c, ,, i _ 04 CITY OF NEWPORT BEACH u i COAUdUNM DEVELOPMENT DEPARTMENT '- I - QQ{t-yµty\P BUILDING DIVI3IONSITE 3,039 S.F. SITE PLAN & PROJECT DATA 100 Civic Center Drive I P.O. Box 17681 Newport Bei, CA 926565915 NOTE: ! www, newoortbeachcaAov I (849) 644.3200 1. POOLS, SPAS, WALLS, FENCES, PATIO COVERS AND OTHER BUILDABLE AREA 1,956 S.F. 2 SURVEY / GRADING --PLAN _ .. . FLOOR AREA LIMIT (2 x 1,956 S.F.) 3,912 S.F. 3 LOWER LEVEL FLOOR PLAN Structural Observation Re rt FREESTANDING STRUCTURES REQUIRE SEPARATE REVIEWS AND 3RD FL. MAX S.F. (15%x 1,956 S.F.) 293.4 S.F. 4 MIDDLE LEVEL FLOOR PLAN PERMITS. VEL FLOOR PLAN 2. FENCES, HEDGES, WALLS, RETAINING WALLS, GUARDRAILS AND Repan Data: CNB bwpectw Name: cNePemar- aaw0reown« PI} owners MffM Aedes (Ifda(ererntrom sft); srelepn * 735-2(as3 CNS Plan check#. Fuff Neme of 5huctwWOhserver o): lk1L iCAii SOE4na Aed . FNWRR'R.G7MA4VCOM SOT f: 119. ciNA2 0c, 180tke'me/Reg.& _10 2. FENCES, HEDGES, WALLS, RETAINING WALLS, GUARDRAILS AND OPEN VOLUME AREA REQ. (15%x 1,956 S.F.) 293.4 S.F. 6 ROOF PLAN I HANDRAILS OR ANY COMBINATION THEREOF SHALL NOT EXCEED 42 OPEN AREA PROVIDED 474 S.F. 7 EXTERIOR ELEVATIONS INCHES FROM EXISTING GRADE PRIOR TO CONSTRUCTION WITHIN OPEN SPACE: 8 BUILDING SECTIONS /WINDOW AND DOOR SCHEDULES THE REQUIRED FRONT SETBACK AREA(S).DECKS 1,290 S.F. 9 LOWER LEVEL ELECTRICAL PLAN I ti ISSUANCE OF A BUILDING PERMIT BY THE CITY OF NEWPORT BEACHCOVERED PATIO 210 S.F. + 10 MIDDLE LEVEL ELECTRICAL PLAN OF - DOES NOT RELIEVE APPLICANTS OF THE LEGAL REQUIREMENTS TO LANDSCAPE AREA 262 S.F. 1 1 UPPER ELECTRICAL PLAN i ! OBSERVE COVENANTS, CONDITIONS AND RESTRICTIONS WHICH MAY L-1 HARDSCAPE PLAN 12 INTERIOR ELEVATIONS OCC: R3/U BE RECORDED AGAINST THE PROPERTY OR TO OBTAIN PLANS. YOU LIVABLE AREA SHEATHING INSPECTION. 1-3 ARCHITECTURAL DETAILS SHOULD CONTACT YOUR COMMUNITY ASSOCIATIONS PRIOR TO 1ST FLOOR 1,150 S.F. APN: 047-282-12 - C-1 EXISTING SITE CONDITIONS AND DEMO PLAN COMMENCEMENT OF CONSTRUCTION AUTHORIZED BY THIS PERMIT. , 2ND FLOOR 1,478 S.F. T24-1 TITLE 24 CALCULATIONS { 4. PRIOR TO PERFORMING ANY WORK IN THE CITY RIGHT -OF WAY- AN 3RD FLOOR 291 S.F. T24-2 TITLE 24 CALCULATIONS I a ENCROACHMENT PERMIT MUST BE OBTAINED FROM THE PUBLIC TOTAL 2,919 S.F. I WORKS DEPARTMENT. I 461 S.F. S-1 FOUNDATION PLAN 5. I ti ISSUANCE OF A BUILDING PERMIT BY THE CITY OF NEWPORT BEACHCOVERED PATIO 210 S.F. + 10 MIDDLE LEVEL ELECTRICAL PLAN OF - DOES NOT RELIEVE APPLICANTS OF THE LEGAL REQUIREMENTS TO LANDSCAPE AREA 262 S.F. 1 1 UPPER ELECTRICAL PLAN i ! OBSERVE COVENANTS, CONDITIONS AND RESTRICTIONS WHICH MAY L-1 HARDSCAPE PLAN ISSUANCE OF A BUILDING PERMIT BY THE CITY OF NEWPORT BEACHCOVERED PATIO 210 S.F. + 10 MIDDLE LEVEL ELECTRICAL PLAN OF - DOES NOT RELIEVE APPLICANTS OF THE LEGAL REQUIREMENTS TO LANDSCAPE AREA 262 S.F. 1 1 UPPER ELECTRICAL PLAN i ! OBSERVE COVENANTS, CONDITIONS AND RESTRICTIONS WHICH MAY L-1 HARDSCAPE PLAN 12 INTERIOR ELEVATIONS OCC: R3/U BE RECORDED AGAINST THE PROPERTY OR TO OBTAIN PLANS. YOU LIVABLE AREA SHEATHING INSPECTION. 1-3 ARCHITECTURAL DETAILS SHOULD CONTACT YOUR COMMUNITY ASSOCIATIONS PRIOR TO 1ST FLOOR 1,150 S.F. APN: 047-282-12 - C-1 EXISTING SITE CONDITIONS AND DEMO PLAN COMMENCEMENT OF CONSTRUCTION AUTHORIZED BY THIS PERMIT. , 2ND FLOOR 1,478 S.F. T24-1 TITLE 24 CALCULATIONS { 4. PRIOR TO PERFORMING ANY WORK IN THE CITY RIGHT -OF WAY- AN 3RD FLOOR 291 S.F. T24-2 TITLE 24 CALCULATIONS I a ENCROACHMENT PERMIT MUST BE OBTAINED FROM THE PUBLIC TOTAL 2,919 S.F. I WORKS DEPARTMENT. GARAGE 461 S.F. S-1 FOUNDATION PLAN 5. A CAL -OSHA PERMIT IS REQUIRED FOR EXCAVATIONS DEEPER THAN TOTAL FLOOR AREA 3,380 S.F. S-2 LOWER LEVEL FRAMING PLAN 5' AND FOR SHORING AND UNDERPINNING.S-3 MIDDLE LEVEL FRAMING PLAN 6. RECYCLE AND/OR SALVAGE FOR REUSE A MINIMUM OF 65% OF THE EXISTING FINISH GRADE CALC (4 CORNER METHOD) S-4 UPPER LEVEL FRAMING PLAN NONHAZARDOUS CONSTRUCTION AND DEMOLITION WASTE IN 1 8.98' SGN STRUCTURAL NOTES +. ACCORDANCE WITH SECTION 4.408.1 CALGREEN CODE. 2 9.90' SD -1 STRUCTURAL DETAILS 7. SPRINKLERS 3 10.36' SD -2 STRUCTURAL DETAILS a. NEW CONSTRUCTION OR ADDITION AND RECONSTRUCTION, 4 9.98' SSW 1 WHICH EXCEED 2 000 SF AND EXCEED 50% OF THE AREA ' TOTAL 39 22 /4 - 9 805 SSW2 THE EXISTING STRUCTURE, REQUIRE INSTALLATION OF A FIRE DRAWN. CHOCKED a_° ifs SPRINKLER SYSTEM THROUGHOUT THE STRUCTURE. ZONE: R-1 L-1 HARDSCAPE PLAN b. OBTAIN FIRE SPRINKLER PERMIT PRIOR TO CALLING FOR ROOF sHSET SHEETS OCC: R3/U L-2 LANDSCAPE PLAN SHEATHING INSPECTION. g BUILDING TYPE: VB c. BUILDING EQUIPPED WITH FIRE SPRINKLER SYSTEM IN APN: 047-282-12 - C-1 EXISTING SITE CONDITIONS AND DEMO PLAN ACCORDANCE WITH NFPA-13D. i ,� i C-2 PRELIMINARY PRECISE GRADING PLAN Y ER OSION CONTROL PRELIMINARY OL PLAN a DEFFERRED SUBMITTALS TO BE REVIEWED BY PROJECT ARCHITECT OR ENGINEER OF RECORD AND CERTIFIED PRIOR TO SUBMITTAL FOR PLAN RCR RESIDENTIAL CONSTRUCTION MINIMUM REQUIREMENTS OnMUM GROMAIM0081»onVOM Axr R83W8mmmFMMANGw fffAUMoMM OMPLOYM OFTM0"OFMM CHECK OR APPROVAL BY THE CITY: CG CAL GREEN RESIDENTIAL MINIMUM REQUIREMENTS 1. FIRE SPRINKLER NFPA-13D 2. HVAC SOUND ATTENUATION - - 3. ELEVATOR AC _., -- AC AC — ------ — c 1� AC ru �L AC A R ❑ l AC jj AC _ Aj1• 1 oPROPERTY LINE Ac C°NC, vi CONC. CONC. C°NC, � CONC. o? V� C°NC, I L6. S1 C°NC, S~ VENT PIPE �rDF `g0 S� 03 VENT PIPE CONC. CONC. a� Ci'Nei WiI�4I/^:�ti..t1 -11 c°N �ti 4 4 c°Nc. �h�S,'o ;L = 7'0,16- s, — °N �� c°Nc. o CONC. ��, fi _ _ _ . .:, _._ . _. FS �ti� _ R= `� _ -i LoZ s , F,P CONC. �°) CONC.`�, � gq,�� t1 S. �� CONC, �4r�21� CONC. 10), Co 001, P c°NC, PRO ERTY LINE 2SJ w 0.6-x- p• - Q1 C°NC, ^ ` l Cl) W Q tiPc�, r��r. _ ���j CONC. 1 i STORY - Z d S S I µ; _ o C921FS) w .�, , CONC. C 67F) I- ¢ o W F �orF �g• s.o ���.� 0jc BUILDING F, Nc. �e �m Z c (28.72) p0� - GATE CONC. 1;> :0;�(92,44FS> RIDGE �� G ti��, -• 0 ELJi�RY CU C❑NC.�}!.. y.� -�,F/�y�.(( C°NC, -'✓"_#,/-L�.3.lF_ ..-1�-`�Yla^�I�7K -. �Y I'' i _ _.____—�Y.�e!.--_6.��i�1_'�!J�i.:��fw^._._.._..,� `Z. ( COG, J ICL HC - yy;., _ SAY - .. Wl NORTH SCALE: 1a=8' S, CONC. N 1�5, = 5 NC. z Uj y ,rte `� PALM u1No= GZtip,l�S, 1F, 1�f "1"J _.._ C.�-"�R...''=r �_.."T'1..1.�✓''T Wit':: �10.14FS) # (10,16FS) _# � <10,14FS) .. ,� iu �`w `�y a 3 y C°NC,— N78°36'59"W 70.00' — ��f�o — —— — — I D L0 I ( CONC. ti� �p C°NC, _._..... _-. C❑NC o rh O w o w _ (36,08) _ 25.0 SCOPE OF WORK: Q G ~ I a cwla dila ala RIDGE _ CONC.. I� CONC., 1� 4.9 `✓ rY rr 8'0 I THE PROJECT IS LOCATED AT 111 8TH ST. AND SITS ON A FLAT LOT AT THE CORNOR OF W. BALBOA BLVD. AND 8TH ST. THERE IS CURRENTLY A ONE (� STORY SINGLE FAMILY RESIDENCE WITH AN ATTACHED TWO CAR GARAGE stip^ , THAT WILL BE DEMOLISHED. THE PROPSED PROJECT CONSISTS OF A 2,919 hw 2 STORY 9 9 I CONC. ����y, S.F. THREE STORY SINGLE FAMILY RESIDENCE WITH AN ATTACHED TWO CAR n BUILDING ~I3 GARAGE OF 461 S.F. THE PROPOSED RESIDENCE CONFORMS TO ALL APPLICABLE SECTIONS OF THE CERTIFIED LOCAL COASTAL PROGRAM AND CONE," I CONC. I WITH THE PUBLIC ACCESS AND PUBLIC RECREATION POLICIES OF CHAPTER L , CONC. fig, 3 OF THE COASTAL ACT. 40 CONC. Ji fU o' CONC. V I� i I Q -0 C> Q .Ln 0, U ' L1Or . O > CX LU C Q U wU 01 - 00 Z CIJ Q U Q� Q O� Q � O� DRAWN. CHOCKED a_° ifs DATE SCALE, J 0 a 1rwo'. OF sHSET SHEETS LOT AREA = 3039 'SQ FT LOT SETBACK AREA = 1,956 SQ FT 0 INDICATES LEAD AND TAG STAMPED L,S, 4653 -EGEND DESCRIPTION (123,45) MEAS, ELEVATIONS ( > REC. BRG, & DIST. DECK # BRICK WALL BUILDING PROPERTY LINE FENCE N, G, NATURAL GRADE P. P, POWER POLE WM WATER METER E.E. FINISH FLOOR G.E. GARAGE FLOOR CONC. CONCRETE F. S, FINISH SURFACE M,H, MAN -HOLE P PLANTER A.C, ASPHALT T. G. TOP -GRATE RdM SURVEYING INC RON MIEDEMA L,S. 4653 23016 LAKE FOREST DR. #409 LAGUNA HILLS, CA 92653 (949) 858-2924 OFFICE (949) 858-3438 FAX RDMSURVEYING@COX.NET IN AC N CONC. iri CONC. CONC. S� �F T❑P❑GRAPHIC SURVEY SFS AC AC -- AC +, BALBOA BLV-D �G AC �G' 3ti _ PROPERTY LINES Ac V CONC. �%cIt, r L�.5� CONC. r m �� CONC. CONC. cb 3 M S� VENT PIPE CONC. q D=0041'44" CONC. �S Jo S CONC. co co PROPERTY LINE z CONC. � P w 0.6� 3� W QOP CONC. (9.67FS) 5.0 �F�, (U CONC. z� y f5.0 CONC. I T CONC. T CONC, Okitit Lti° S CONC. VENT PIPE CONC. L=70,16' CONC. CONC. I STORY BUILDING (28.72) RIDGE --p CONC. S' �G �CONC. �CONC. R=5779,65' q/ — PROPERTY LINE coNc. F� CONC. I _ a- z (9.21FS) z a o W �� GATE - CONC. (� �(9.44FS)� Ln CONC. o o -z CONC. Z �1 w v PROPERTY LINE ��� 16.1 L_ PALM o �(10.14FS) # (10.162) # (1014FS)4*�_j �u N78036'59"W 70.00' �S� FS; ti� so Lo o CONC. m u Co wu RIDGE c ra om ca 2 STORY BUILDING OWNER: CHRIS BENGSTON 111 8TH STREET NEWPORT BEACH, CA 8.0 I+— 9.9 —► CONC. o+ °' �Ln Jug CONC. m Co_j o AC CONC. HC 1Jp 25.0 CONC. CONC C�� S, �F ` CONC. �m W CONC. LEGAL DESCRIPTI❑N- I BENCH MARK LOT 1 OF BLOCK 7 OF EAST NEWPORT TRACT, BENCH MARK # IE -122-14 NAVD88 ELEVATION= 9.179 NORTH 0' 8' 16' SCALE 1"=8' NOTE: RECORD EASEMENTS ARE NOT PLOTTED IF ANY. C Q 0 C) ♦a LmLj W � 00 ■ r CC) CL r' Z VGA LAND S��\ J RON MI MEAEA * N0. 4653 EXP. 9/30/17 ti E C IAO/ ADDRESS OF PROJECT: 111 8TH STREET NEWPORT BEACH, CA JOB: 60-34 DATE: 5,/16/16 r` �i REVISIONS BY ■ DRAWN CHECKED DATE GALE, �P JOB Pia. SHEET r OF SHEETS 12 ?9 o a t (D cu co 00 ?9 I i 1 REVISIONS BY DRAWN CHECKED DATE SCALE '1 JOB NO. SHEET 51, OF SHEETS 20 1 II _. ------------------- �k �l COLOR CHART 1 STUCCO DUNN-EDWARDS HICKORY # DEC759 2 ROOF EAGLE CAPISTRANO HILO SUNSET # 3124 3 STONE ELDORADO MESETA FIELDSTONE WITH GRAY GROUT 4 CONCRETE PACIFIC STONE # 33 5 WOOD STAIN OLYMPIC BLACK WALNUT # 709 6 WINDOWS ANODIZED DARK BRONZE 7 WROUGHT IRON RAIL BLACK POWER COAT ML�xtMuM REVISIONS I BY nii el DRAWN CHECKED DATE SCALE A =1 I,6� JOB NO. SHEET 7 OF SHEETS 22 i n it � k . s lap w Is, ins 1. WINDOWS ARE METAL CLAD O/ HOOD WITH DUAL LOW 'E' '` GLAZING. -- ctu 2. TEMPERED GLAZING TO HAVE SAFETY LABEL PERMANENTLY r : ATTATCHED. 3. U -FACTOR: 0.280 4. SOLAR HEAT GAIN COEFFICIENT (SHGC): 0.35 ^ 5. FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT LABELS. 4j < t�- Murr%___. �.•�D �GUG�>T�1r'.� Fp `�'[%t`l ap, I 85' T o 4�r1►.I� C3°cod 1a �1 Tv -w 1. ALL GLAZING AT DOORS TO BE DUAL AND LOW 'E' " _ 2. TEMPERED WITH SAFETY LABEL PERMANENTLY ATTACHED, } i 3. U -FACTOR: 0.280 d 4. SOLAR HEAT GAIN COEFFICIENT (SHGC): 0.35 11 5. FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT LABELS. DRAWN CHECKED DATE ( SCALE ( { ilyl .Q JOB NO. SHEET 8 IOF SHEETS 2s DWG VIE �NCLUU.�1/ TQRRI O COMPANY F AMERICA ,,.00;cnnac PA V F7I2DER I�ccc R£—NCE PROJECT, TYPICAL MRL 950 GEARED DRIVE MANUFACTURED TO MEET: ASME A17.1 - 2013 STANDARDS S PE CIFC I F�GTTf'1 AIG MODEL- UC601 - 'MRL' GEARED DRIVE - 200 LANDINGS- MAXIMUM 6 LANDINGS CODE(S)- 5 (INCLINATOR LAYOUT DESIGNATION) CAPACITY: 950# SPEED; AT 38 F.P.M.i2 SUSPENSION (2) #60 ROLLER CHAINS MEANS- CAR CONSTRUCTION- 3/4' HARDWOOD VENEER N%HM: ALL MMRIF..CIURER SUNNIER ONH AND, El RP W ME NOTW ON THE WNFtlb.9N43 OROEN SHEEE. nlM, srNER, ONCE DRAWINGS HAVE BEEN APPROVED, SIGNED AND WITHIN 5 DAYS OF PRODUCTION, .THE CUSTOMER WILL BEM ALL RESPONSIBILITY AND LIABILITY OF FINISHED UNIT. PART A SEE DETAIL "RAIL" 27" 10 POST GATE � 121" . .131" 131' 131" LIGHT CURTAIN - 36" " L. ' 471'10 DOOR i , 20 DOOR INTERLOCK I 1. MRL FEARED - ROD !j ( 7'H -OVERALL 3617 SWH-CLEAR ID ID / 321"t 227 WDE(S) 5 4! CLEAR 1 OVERHEAD DOOR INTERLOCK-..-..........,_. CALL STATION 42` ABOVE FINISHED FLOOR Y 50 -CAR C. MINIMUM OVERHEAD 53"FINISHED HATCH NININLIM CAR WIDTH FOR THE NRL [FARE IS 42• NOTE, ALL HOISTWAY CONSTRUCTION MUST COMPLY WITH NATIONAL, STATE, AND LOCAL CODES. HUISTWAY MUST BE PLUMB AND STRAIGHT FROM TOP TO BOTTOM WITH NO PROJECTIONS INTO THE HOISTWAY. 101"R.C. 511" FINISHED HATCH 38" CAR ,ELECTRICAL NOTES: • t. Bathroom exhaust fans which exhaust directly from bathroom shall comply with CGBS 4.5o6 and shall include the following: a. Be Energy star efficient b. Unless functioning as a component of a whole house system, fans must be controlled by a humistat which shall II Y be readily accessible between a relative humidity Of 50% to 80%- 2. Rooms containing bathtubs, showers, spas and similar bathing fixtures shall be mechanically ventilated and Educted to the outside. A minimum rate of 5ocfm and a maximum sound rating of 3 Sone for intermittent operation is required. 1 3. Kitchen exhaust hood shall exhaust to outside. A minimum rate of too cfm and a maximum sound rating of 3 Sone is required for intermittent operation. \ 4. All lighting in a residential building shall be high efficacy (except kitchen lighting), or depending on the location of the lighting, be controlled by a dimmer switch of a manual on vacancy sensor. 5. Bathroom lighting to be high efficacy or controlled by a. vacancy sensor. ' 6. Kitchen lighting shall be high efficacy until a minimum of 50% of the total wattage of permanently installed Fighting is -;=-----... high efficacy. 7. Recessed lighting installed in an insulated ceiling shall be s listed as ATTIC and sealed andlor contain a gasket. 8. Smoke detectors and Carbon Monoxide Alarm in a i i// • •' accordance with Section R315.1 shall be installed in the -- _ - - following locations: _---_—.------_ REV.DATE a. Smoke detectors to be installed in each sleeping room. - b Sm Carbon monoxide alarms are v.LEyEL(t -3) + -- --^— ---, ; ' ��- required detectors redoutside of each separate dwelling unit -�- i sleeping area in the immediate vicinity of the � %( bedrooms. NY ; .! : ,; ctors and Carbon Monoxide AA► c. Smoke dete alarms are ! wired on each additional story and/or every level of f r� req f 1,,' the dwelling, including basements and habitable attics. < d. Where more than one smoke detectors/ Carbon to be installed within the ,' i Monoxide alarms is required a sleeping unit, the alarm shall dg wellin unit or within p g C t activation of one Y be interconnected in a manner tha 1 , 1 unit. individual un e alarms in the l �, ; ,• ' . ; : , : alarm shall activate all the t + i All �3R I , • -':. ... I - ,;. - ... -. , Smoke detector Carbon Monoxide alarms shall receiv e 3• ERN CLEARANCE f , e. S 1 NEEDED ON ONE wiring and be .EE ,.,!. , ... ... .. ....„,,... ,� ._._..-,..-. -�,.- -'-.1. , .. , _ .. " their primary - power from the building g ,t R.C. 3IIE Gr CAR FIXt P Y Po TRAVELING ING A ,y �y II VEL CABLE }"�(�S t'IZ3' r i , AS' '�: 1 e... u..r.n.l .with o hattary harknn. . _..... .._ _ .. 57J`. HATCH 53' HATCH DOOR INTERLOCK MINIMUM OVERHEAD NOTE, IF CAR IS 8'H THEN MINIMUM OVERHEAD 3RD OF 9'-6• IS NEE BED 9 50' MAX TRAVEL: 2ND q IST 8" MINIMUM PR bMIX 3DOD PSI R REINFORCED ONCRETE ' S •1• a•'"' N4 AT 12' O.C. EACH MAY < •% + ' N ,C„F�fTIDN A -A SECTION B -B DWG VIEW PART NUMBER REV.DATE SECTION VIEWS _ _ DRAWING TITLE DRAWING NO. TYP - GEARED DRIVE MlIll PACE: DRAWN BY: G. DATE I DWAl JOB OR A DEALER P.0' ,DWG SCALEIREV.LEVEL 1-3 kitchen outlets, laundry, utility and wet bar outlets located 1 1 S within m 6 feet. Ece t n. A receptacle supplying only a t permanently installed fore alarm or burglar alarm CECz to I ' , , r , ' ' q , t Receptacles shall be listed as tamper -resistant for all 15 CSF( I r ;. :; ti�+Gi : T 3 P P }TRS' ` _ and zo am ere r tacles in dwelling unit fain;/ linin I, PP g Y, g, living, parlors, libraries, dens, bedrooms, sunrooms, • � ;;; " � „ _ , , ",';. . " .,' recreation rooms, closets, hallways, or similar rooms and i areas per CEC sections 210.12 and 4o6m 14. Arcfault Circuit Protection (AFCI) is required for all 15 and i zo ampere branch circuits supplying outlets in dwellingiunit family, dining, living, parlors, libraries, dens, bedrooms, ` - sunrooms, recreation rooms, closets, hallways, or similar �••� � r n . rooms and areas per CEC sectio 21012 IELECTRICAL LEGENDr . ;,� .,_ , _, - • 15. Provide at least one receptacle outlet in bathroom within T K'- - S I E' LIGHT, WATER PRO:O'F �� 36 inches of the outside edge of each sink basin. Outlet + DUPLE ELECTRICAL OUTLET 110 � PUSH BUTTON CONTROL �.1 shall be located on a wall or partition that is adjacent to the 1 K�-- OUTLET 1/2 S W ITCHED E2ii{_ ENTRY CHIMES basin or installed on the side of face the basin cabinet not more than 12" below the countertop. V � ! ll OUTLET 220 TELECOM JACK 16. Provide a min. of 1 zoam circuit for bathroom s outlet SWITCHED OUTLET TYPE MM ENHANCED MULTI MEDIA JACK O P ( ) r ,� $ j Such circuit shall have no other outlets. Loads shall be OUTLET EXTERIOR MULTIMEDIA JACK balanced. - -----� j OUTLET GROUND FAULT PROTECTED JUNCTION BOX 17. Provide a minimum ofz-zoamp small appliance circuits for #$ OUTLET ARC FAULT PROTECTED FLUOR. TUBE the kitchen counter tops. Such circuit shall have no other outlets. Loads shall be balanced. G1 sTlv�l l r WATER PROOF , EXTERIOR FLUOR. RECESSED FIXTURE- is. Provide a minimum of 1-2o amp laundry branch circuit such MIN-_ rrfhl_�jipt ?�J� ° I SWITCH SINGLE SWITCH W . VACANCY SENSOR circuits shall have no other outlets. 2 �fwl _ MOLT- WAY SWITCH Fife SWITCH W/ MOTION SENSOR TIMER f�- 1g. A dedicated circuit, sized for the appliance is required for MULTIPLE SWITCHING CARBON MONOXIDE SENSOR (TO BE INTERCONNECTED) dumb waiter equipment. C SMOKE DETECTOR RHEOSTATIC DIMMER CONTROL (TO BE INTERCONNECTED) i �j 20.ALL LIGHTING SHALL BE HIGH EFFICACY PER SECTION 150.0 9 (K). RECESSED CEILING 'LIGHT A EXHAUST FAN 51AIR CHANGES PER HOUR I` 21. HOT WATER HEATER SHALL VENT DIRECTLY THROUGH ROOF. � --� 22. ALL LOWER LEVEL EXTERIOR ENVELOPE WALLS MIN 2X6 TO NOTE: J&WALL LIGHT -17j-� FUEL GAS LOCATION FOR GAS METER, WATER METER, ELECTRICAL SURFACE MOUNTED CEILING LIGHT FUEL VALVE SHUT OFF KEY I ACCOMMODATE R-21 BATT INSULATIONS. 1. VERIFY O `. � " 23. IN KITCHEN, LOCAL EXHAUST SYSTEM VENTED TO OUTDOORS SHALL METER, PHONE BOX, T.V. CABLE BOX, AND PROVIDE POWER AND � HANGING CEILING LIGHT KIDF JI' HAVE A MINIMUM EXHAUST RATE OF 100 CFM. NKLERS. ir= FLUORESCENT TUBE LIGHTING + 24.ALL PLUMBING FIXTURES SHALL BE COMPLYING WITH THE MAXIMUM.: TRANSFORMER FOR LANDSCAPE LIGHTS AND SPR- I T, NI MEDIA CABLE.(VERIFY TYPE) .. SIN SECTION 4.303 CALGREENILDING STANDARDS TELEGOMUNICATIQ GABLI` (VERfi Y) , A.. DATE 24 1534T -7W9 is a DRAWN CHECKED co R4 co (> SHEET 1-0 OF SHEETS co, Lo L.L01� a� Z > x to 4-a 0 u cv- CL Illu. cy') U�z ol 00 010, ci-5 C�) U ILc) �Q q 00- DRAWN CHECKED DATE R4 JOB NO. 1, 1 SHEET 1-0 OF SHEETS L) to 4-a 0 00 CL U�z DRAWN CHECKED DATE R4 JOB NO. 1, 1 SHEET 1-0 OF SHEETS DRAWN CHECKED gDA,}}►TE r"I f, ) �f JOB NO. SHEET OF SHEETS 20 �M ✓`_ Yr_"�aa�i'-r i 'r" J VOL 400 I REVISIONS I BY i 00 Lo. -0 c0-' o CV CN U:� L z� O LIJ�� �L. � Q wU U}Lo Q Q o0- c O � U � s c)) 4.0 L) �� N D s - 'n U) •C/)pip Q � N "U z DRAWN CHECKED DATE JOB NO. SHEET 12 OF SHEETS 27 DRAWN CHECKED DATE SCALE JOB NO. SHEET 14 OF SHEETS A 11 L� a 0 0 NEaA im, N BALBQA BLVD 01 25 t I L r_,_.1 991170-20 t7— PRKtED ON CLEARPRIW 1000H• +70 �j J A _,3� I iffm� loop �WM '"ENO 'U111111 V "A CONSTRUCTION LEGEND ExIstina Site Items Concrete Curb and Gutter - To Remain Concrete Sidewalk - To Remain Fc� concrete Access Ramp - To be Removed (Reconstruct) per STD -1 81 -L-B, Case "J" (See Civil Plans) ® Concrete Apron at Alley - To be Removed (Plugged) per STD -1 65-L (See Civil Plans) RE Concrete Alley - To Remain (Verify) [D Existing Drainage Inlet In Alley - To Remain nG Sewer Manhole - To Remain Water Meter Service - To Remain (Protect in place] (See Civil Plans) ni Cable Box - To Remain (Protect in place) nJ Edison Box - To Remain (Protect in place) KK Sign - To Remain Steel Barrier Post - To be Removed Existing Fire Hydrant - To Remain nN Existing Water Valve - To Remain [D Existing Vent Pipe To Remain FPJ Property Line Sewer clean out To be Relocated (Sea- Civil Plan) Now Constnwtion Items (D New Masonry Property Line Wall See Plan for heights and Detail on Sheet L-1") New Alley Approach per city Standard STD442-1- New .Interlocking Concrete Paving New Interlocking Concrete Steps New Decorative Wood Side Yard Gate Trash Can Storage under Stairs 07 New Landscape Area . ........ V-00 -T7 SITE PLAN .-S ; CALEAW 0'-0" ............. CAP BLOCK (OPTIONAL) I ) n4 HORIZONTAL IN 8LOCK BOND SEAM 44 VERTICAL - SEE TAME BELOW FOR SPACING (I) "4 HORIZONTAL MID I -EQ -IT OF WALL IN BLOOK B" BEAM U4 DOWELS (2) #4 CONTIKUOLSS Construction Plan CMAWN CHECKSO 9-7-17 11111CALS Joe MO. 8"nom co Z N 0 W Z.s LL,0 00 t: 0 Z Construction Plan CMAWN CHECKSO 9-7-17 11111CALS Joe MO. 8"nom m � -141 " K" 4 -0-1;1 �;T! �� I AYJiI'] Planting Plan jW p 0 K 216-030 swerr L-2 OF SHOOTS n VM (o Z N 01�m -co) UJ 0 Z I=" c Lu U) 0 _� 0 z Planting Plan jW p 0 K 216-030 swerr L-2 OF SHOOTS n GENERAL GRADING NOTES: 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE GRADING ORDINANCE AND DESIGN STANDARDS OF THE CITY OF NEWPORT BEACH AND ANY SPECIAL REQUIREMENTS OF THE PERMIT. 2. NO GRADING SHALL BE STARTED WITHOUT FIRST NOTIFYING THE CITY ENGINEER. A PRE -GRADE MEETING IS REQUIRED BEFORE START OF GRADING WITH THE FOLLOWING PEOPLE PRESENT: OWNER, GRADING CONTRACTORS, DESIGN CIVIL ENGINEER, SOILS ENGINEER, GEOLOGIST, CITY GRADING INSPECTOR OR THEIR REPRESENTATIVES, AND WHEN REQUIRED, THE ARCHAEOLOGIST, PALEONTOLOGIST AND/OR OTHER UTILITY REPRESENTATIVES. 3. THE PERMITTEE OR HIS AGENT SHALL NOTIFY THE ENGINEERING DIVISION WHEN THE GRADING OPERATION IS READY FOR EACH OF THE FOLLOWING INSPECTIONS. A. INITIAL INSPECTION: WHEN THE PERMITTEE IS READY TO BEGIN WORK, BUT NOT LESSTHAN TWO DAYS BEFORE ANY GRADING OR BRUSHING IS STARTED. B. TOE INSPECTION: AFTER THE NATURAL GROUND OR BEDROCK IS EXPOSED AND PREPARED TO RECEIVE FILL, BUT NOT BEFORE THE FILL IS PLACED. C. EXCAVATION INSPECTION: AFTER THE EXCAVATION IS STARTED, BUT BEFORE THE VERTICAL DEPTH OF THE EXCAVATION EXCEEDS TEN FEET. D. FILL INSPECTION: AFTER THE FILL PLACEMENTS STARTED, BUT BEFORE THE VERTICAL HEIGHT OF THE FILL EXCEEDS TEN FEET. E.DRAINAGE DEVICE INSPECTION: AFTER FORMING OF TERRACE DRAINS, DOWNDRAINS, OR AFTER PLACEMENT OF PIPE IN SUBDRAINS, BUT BEFORE ANY CONCRETE OR FILTER MATERIAL IS PLACED. F. ROUGH GRADING: WHEN ALL ROUGH GRADING HAS BEEN COMPLETED. THIS INSPECTION MAY BE CALLED FOR AT THE COMPLETION OF ROUGH GRADING. G. FINAL: WHEN ALL WORK INCLUDING INSTALLATION OF ALL DRAINAGE STRUCTURES AND OTHER PROTECTIVE DEVICES HAS BEEN COMPLETED AND THE AS -GRADED PLAN, PROFESSIONAL CERTIFICATIONS AND THE REQUIRED REPORTS HAVE BEEN SUBMITTED. 4. CUT SLOPES SHALL BE NO STEEPER THAN 2 HORIZONTAL TO 1 VERTICAL. 5. FILL SLOPES SHALL BE NO STEEPER THAN 2 HORIZONTAL TO 1 VERTICAL AND SHALL HAVE NOT LESS THAN 90% COMPACTION OUT TO THE FINISHED SURFACE. 6. FILLS SHALL BE COMPACTED THROUGHOUT TO A MINIMUM OF 90% RELATIVE DENSITY. MAXIMUM DENSITY TO BE DETERMINED BY ASTM -D1557 (FIVE (5) LAYER TEST) OR APPROVED EQUIVALENT, AND FIELD DENSITY BY UNIFORM BUILDING CODE STANDARD NO. 70-2, OR APPROVED EQUIVALENT. 7. AREAS TO RECEIVE FILL SHALL BE PROPERLY PREPARED AND APPROVED BY THE SOILS ENGINEER AND/OR ENGINEERING GEOLOGIST PRIOR TO PLACING OF FILL. 8. FILLS SHALL BE BENCHED INTO COMPETENT MATERIAL AS PER DETAIL ON PLAN. 9. ALL EXISTING FILLS SHALL BE APPROVED BY THE SOILS ENGINEER OR REMOVED BEFORE ANYADDITIONAL FILLS ARE ADDED. 10. THE EXISTING IRRIGATION LINES, SUBGRADE STRUCTURES, SEPTIC TANKS, AND CISTERNS SHALL BE REMOVED, OR CRUSHED IN PLACE AND BACKFILLED, AND APPROVED BY THE CITY INSPECTOR AND SOILS ENGINEER. 11. THE STOCKPILING OF EXCESS MATERIAL SHALL BE APPROVED BY THE CITY ENGINEER PRIOR TO EXCAVATION. 12. THE DESIGN CIVIL ENGINEER, PRIOR TO ROUGH GRADE APPROVAL, SHALL PROVIDE THE MINIMUM OF ONE BLUE TOP PER LOT, SET AT THE HIGHEST POINT IN THE FINISHED DRAINAGE SCALE. 13. ALL TRENCH BACKFILLS SHALL BE TESTED AND APPROVED BY THE SITE SOILS ENGINEER PER THE GRADING CODE. 14. THE ENGINEERING, GEOLOGIST AND SOILS ENGINEER SHALL, AFTER CLEARING AND PRIOR TO THE PLACEMENT OF FILL IN CANYONS, OBSERVE AND REVIEW EACH CANYON FOR AREAS OF ADVERSE STABILITY AND TO DETERMINE THE PRESENCE OR ABSENCE OF SUBSURFACE WATER OR SPRING FLOW. IF NEEDED, DRAINS (IN ADDITION TO THOSE DEPICTED ON THIS PLAN) WILL BE DESIGNED AND CONSTRUCTED PRIOR TO THE PLACEMENT OF FILL IN EACH RESPECTIVE CANYON. ANY ADDITIONS SHALL BE NOTED ON THE "AS -BUILT" PLANS. 15. SUBDRAIN OUTLETS SHALL BE COMPLETED AT THE BEGINNING OF THE SUBDRAIN CONSTRUCTION. 16. THE EXACT LOCATION OF THE SUBDRAINS SHALL BE SURVEYED IN THE FIELD FOR LINE AND GRADE AND NOTED AND SHOWN ON THE "AS -BUILT" PLANS. 17. ALL CUT SLOPES SHALL BE INVESTIGATED BOTH DURING AND AFTER GRADING BY AN ENGINEERING GEOLOGIST TO EVALUATE THE STABILITY OF EACH SLOPE SHOULD EXCAVATION DISCLOSE ANY GEOLOGICAL HAZARDS OR POTENTIAL GEOLOGICAL HAZARDS, THE ENGINEERING GEOLOGIST SHALL RECOMMEND NECESSARY TREATMENT TO THE CITY ENGINEER FOR APPROVAL. ALL APPROVAL TO BE GRANTED ON THE BASIS OF DETAILED GEOLOGICAL MAPPING AND WRITTEN FIELD MEMO. 18. WHERE SUPPORT OR BUTTRESSING OF CUT AND NATURAL SLOPES IS DETERMINED TO BE NECESSARY BY THE ENGINEERING GEOLOGIST AND SOILS ENGINEER, THE SOILS ENGINEER WILL SUBMIT DESIGN, LOCATIONS AND CALCULATIONS TO THE CITY ENGINEER PRIOR TO CONSTRUCTION. THE ENGINEERING GEOLOGIST AND SOILS ENGINEER WILL OBSERVE THE CONSTRUCTION OF THE BUTTRESSING AND COMMENT ON THE STABILITY OF THE SLOPE AND ADJACENT STRUCTURES UPON COMPLETION. ALL CHANGES SHALL BE ADDRESSED IN THE FINAL SOILS REPORT. 19. WHEN CUT PADS ARE BROUGHT TO NEAR GRADE, THE ENGINEERING GEOLOGIST SHALL DETERMINE IF THE BEDROCK IS EXTENSIVELY FRACTURED OR FAULTED AND WILL READILY TRANSMIT WATER. IF CONSIDERED NECESSARY BY THE ENGINEERING GEOLOGIST AND SOILS ENGINEER, A COMPACTED FILL BLANKET WILL BE PLACED. 20. THE ENGINEERING GEOLOGIST OR HIS REPRESENTATIVE SHALL BE ON SITE FOR OBSERVATION AND TESTING, AS NECESSARY, AND SUBMIT A COMPLETE REPORT AND MAP UPON COMPLETION OF THE ROUGH GRADING. 21. THE FINAL COMPACTION REPORT AND APPROVAL FROM THE SOILS ENGINEER SHALL CONTAIN THETYPE OF FIELD TESTING PERFORMED. EACH TEST SHALL BE IDENTIFIED WITH THE METHOD OF OBTAINING THE IN-PLACE DENSITY, WHETHER SAND CONE OR DRIVE RING, AND SHALL BE SO NOTED FOR EACH TEST. SUFFICIENT MAXIMUM DENSITY DETERMINATIONS SHALL BE PERFORMED TO VERIFY THE ACCURACY OF THE MAXIMUM DENSITY CURVES USED BY THE FIELD TECHNICIAN. 22.THE SOILS ENGINEER AND ENGINEERING GEOLOGIST SHALL PROVIDE OBSERVATION AND TESTING, SERVICES, AS NECESSARY, AND BE AVAILABLE DURING GRADING TO VERIFY COMPLIANCE WITH THE PLANS, SPECIFICATIONS, AND CODE WITHIN THEIR PURVIEW. 23. THE DESIGN CIVIL ENGINEER SHALL EXERCISE SUFFICIENT CONTROL DURING GRADING AND CONSTRUCTION TO INSURE COMPLIANCE WITH THE PLANS, SPECIFICATIONS, AND CODE WITHIN HIS PURVIEW. 24.DUST SHALL BE CONTROLLED BY WATERING. 25.SANITARY FACILITIES SHALL BE MAINTAINED ON THE SITE. 26. THE LOCATION AND PROTECTION OF ALL UTILITIES ARE THE RESPONSIBILITY OF THE GRADING CONTRACTOR. 27. APPROVED PROTECTIVE MEASURES AND TEMPORARY DRAINAGE PROVISIONS MUST BE USED TO PROTECT ADJOINING PROPERTIES DURING THE GRADING PROJECT. 28. PRIOR TO FINAL APPROVAL, THE DESIGN CIVIL ENGINEER SHALL CERTIFY TO THE ENGINEERING DIVISION THE NUMBER OF YARDS TO CUT FILL AND IMPORT MOVED DURING THE GRADING OPERATIONS. 29. ALL CONCRETE STRUCTURES THAT COME IN CONTACT WITH THE ON-SITE SOILS SHALL BE CONSTRUCTED WITH TYPE 5 CEMENT UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER. 30.EXPORT SOIL MUST GO TO A LEGAL DUMP OR TO A PERMITTED SITE APPROVED BY THE CITY ENGINEER. 31. SLOPES EXCEEDING FIVE FEET IN HEIGHT MUST BE PLANTED WITH A PLANT MATERIAL DESIGNED BY A REGISTERED LANDSCAPE ARCHITECT AND APPROVED BY THE CITY AND MUST BE PROVIDED WITH AN APPROVED IRRIGATION SYSTEM. 32. PRIOR TO FINAL APPROVAL, THE GRADING CONTRACTOR SHALL SUBMIT A STATEMENT OF COMPLIANCE FOR THE APPROVED GRADING PLAN. 33.FOR GRADING PERMITS ISSUED BEFORE AUGUST 15, EROSION CONTROL PLANS, IF NECESSARY, SHALL BE REQUIRED AND SHALL BE SUBMITTED TO AND APPROVED BY THE CITY ENGINEER BY SEPTEMBER 15. FOR GRADING PERMITS WHICH ARE ISSUED AFTER AUGUST 15, AND WHERE GRADING IS NOT EXPECTED TO BE COMPLETED BY OCTOBER 15, EROSION CONTROL PROVISIONS SHALL BE REQUIRED. 34. THE APPROVED SOIL ENGINEERING REPORT PREPARED BY . DATED AND ALL REVISIONS ARE TO BE CONSIDERED PART OF THE PLANS, AND THERE RECOMMENDATIONS CONTAINED THEREIN ARE TO BE ADHERED TO. 35. CONCRETE FOR SIDEWALK, CURB & GUTTER, ACCESS RAMPS, AND DRIVE APPROACHES SHALL HAVE A MINIMUM ULTIMATE COMPRESSIVE STRENGTH AT 28 DAYS OF 3250 PSI. CONCRETE MAY BE PNEUMATICALLY PLACED AND SHALL CONFORM TO SECTION 201 OF THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION (GREENBOOK). 36. CONCRETE FOR EXTERIOR RETAINING WALLS AND STRUCTURAL FOUNDATIONS SHALL HAVE A MINIMUM ULTIMATE COMPRESSIVE STRENGTH AT 28 DAYS OF 4500 PSI WITH A WATER -CEMENT RATIO OF 0.45. 37.CONCRETE REINFORCING SHALL BE 6" X 6 - w 1.4 WELDED WIRE MESH W.W.M. OR APPROVED EQUAL. ( ) Q 38. GROUND SHALL BE PREWETTED TO THE SATISFACTION OF THE CITY INSPECTOR OR THE SOILS ENGINEER PRIOR TO PLACEMENT OF CONCRETE. MOISTURE LOSS RETARDANT SHALL BE USED WHEN REQUIRED BY THE SOILS ENGINEER. 39.FOR COMPACTED FILL: A. A MINIMUM FOUNDATION BEARING VALUE OF 1500 P.S.F. IS REQUIRED UNLESS MODIFIED BY THE SOILS REPORT. B. NUMBER OF TESTS TO BE MADE SHALL BE: 1 TEST FOR EACH 2 FEET OF FILL OR 1 TEST FOR EACH 1,000 CUBIC YARDS (WHICHEVER IS GREATER). 40.THE UNDERSIGNED CIVIL ENGINEERS WILL BE RESPONSIBLE FOR THE MINIMUM PROFESSIONAL INSPECTIONS IN ACCORDANCE WITH SUBARTICLE 14 OF THE CITY OF NEWPORT BEACH'S GRADING ORDINANCE & GRADING MANUAL. 41. DETRIMENTAL AMOUNTS OF ORGANIC MATERIAL SHALL NOT BE PERMITTED IN FILLS. EXCEPT AS OUTLINED BELOW, NO ROCK OR SIMILAR IRREDUCIBLE MATERIAL WITH A MAXIMUM DIMENSION GREATER THAN TWELVE (12) INCHES SHALL BE BURIED OR LACED IN FILLS. A. THE SOILS ENGINEER MAY PERMIT PLACEMENT OF LARGER ROCK WHEN THE SOILS ENGINEER PROPERLY DEVISED A METHOD OF PLACEMENT, CONTINUOUSLY INSPECTS PLACEMENT, AND APPROVES THE FILL STABILITY AND COMPETENCY. THE FOLLOWING CONDITIONS SHALL ALSO APPLY: B. PRIOR TO ISSUANCE OF THE GRADING PERMIT, POTE ROCK T Q�OVESS/ONq� I ��� SEVEN yds F� w Z DI68795 AL TOLL FREE 800 227-2600 No. iC Exp s-30-2o-zots t Least Two Working Days Jj IVI Before You Dig �TFOF CAUF� PRELIMINARY PRECISE GRADING PLAN FOR 111 8TH STREET DISPOSAL AREA(S) SHALL BE DELINEATED ON THE GRADING PLAN. C. ROCK SIZES GREATER THAN TWELVE (12) INCHES IN MAXIMUM DIMENSION SHALL BE TEN (10) FEET OR MORE BELOW GRADE, MEASURED VERTICALLY. THIS DEPTH MAY BE REDUCED UPON RECOMMENDATION OF THE SOILS ENGINEER AND APPROVAL OF THE BUILDING OFFICIAL PROVIDING THAT THE PERMITTED USE OF THE PROPERTY WILL NOT BE IMPAIRED. D. ROCKS GREATER THAN TWELVE (12) INCHES SHALL BE PLACED SO AS TO BE COMPLETELY SURROUNDED BY SOILS; NO NESTING OF ROCKS WILL BE PERMITTED. E. ALL RECOMMENDATIONS SHALL BE REVIEWED AND APPROVED BY THE CITY. 42.GRADING OPERATIONS AND MAINTENANCE OF EQUIPMENT WITHIN ONE HALF MILE OF HUMAN OCCUPANCY SHALL NOT BE CONDUCTED BETWEEN THE HOURS OF 5:30 P.M. AND 7:30 A.M. OR ANY TIME ON A SATURDAY, SUNDAY OR A CITY HOLIDAY. 43: THE DESIGN ENGINEER SHALL CERTIFY ALL HORIZONTAL LINES AND VERTICAL GRADES PRIOR TO RELEASE OF GRADING. 44. CONSTRUCTION SITES SHALL BE MAINTAINED IN SUCH A CONDITION THAT AN ANTICIPATED STORM DOES NOT CARRY WASTES OR POLLUTANTS OFF THE SITE. A. ALL EROSION PROTECTION DEVICES MUST BE IN PLACE EACH DAY THE RAIN PROBABILITY FORECAST IS EQUAL TO OR GREATER THAN 40%. AFTER A RAIN EVENT (OR DURING AN EXTENDED EVENT IF NECESSARY), ALL EROSION PROTECTION DEVICES SHALL BEINSPECTED AND REPAIRED/CLEANED AS NEEDED TO ENSURE PROPER FUNCTION. B. DISCHARGES OF MATERIAL OTHER THAN STORMWATER ('NON-STORMWATER" DISCHARGES) ARE ALLOWED ONLY WHEN NECESSARY FOR PERFORMANCE AND COMPLETION OF CONSTRUCTION PRACTICES AND WHERE THEY DO NOT: CAUSE OR CONTRIBUTE TO A VIOLATION OF ANY WATER QUALITY STANDARD; CAUSE OR THREATEN TO CAUSE POLLUTION, CONTAMINATION, OR NUISANCE; OR CONTAIN A HAZARDOUS SUBSTANCE IN A QUANTITY REPORTABLE UNDER FEDERAL REGULATIONS 40 CFR PARTS 117 AND 302. SITE SHALL INCLUDE BEST MANAGEMENT PRACTICES (BMPS) TO REDUCE THE QUANTITY (AMOUNT AND NUMBER OF INCIDENCES) OF NON-STORMWATER DISCHARGES AND TO IMPROVE THE QUALITY OF ANY NON-STORMWATER DISCHARGES. C. STORMWATER AND NON-STORMWATER DISCHARGES SHALL NOT CARRY WASTES OR POLLUTANTS OFF THE SITE. POTENTIAL POLLUTANTS INCLUDE BUT ARE NOT LIMITED TO: SOLID OR LIQUID CHEMICAL SPILLS; WASTES FROM PAINTS, STAINS, SEALANTS, GLUES, LIMES, PESTICIDES, HERBICIDES, WOOD PRESERVATIVES AND SOLVENTS; ASBESTOS FIBERS, PAINT FLAKES OR STUCCO FRAGMENTS; FUELS, OILS, LUBRICANTS, AND HYDRAULIC, RADIATOR OR BATTERY FLUIDS; FERTILIZERS, VEHICLE/EQUIPMENT WASH WATER AND CONCRETE WASH WATER; CONCRETE, DETERGENT OR FLOATABLE WASTES; WASTES FROM ANY ENGINE/EQUIPMENT STEAM CLEANING OR CHEMICAL DEGREASING; AND SUPERCHLORINATED POTABLE WATER LINE FLUSHINGS. D. DURING CONSTRUCTION, DISPOSAL OF SUCH MATERIALS SHOULD OCCUR IN A SPECIFIED AND CONTROLLED TEMPORARY AREA ON-SITE, PHYSICALLY SEPARATED FROM POTENTIAL STORM WATER AND NON-STORMWATER RUN-OFF, WITH ULTIMATE DISPOSAL IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL REQUIREMENTS. E. THE PERMITTEE SHALL NOTIFY ALL GENERAL CONTRACTORS, SUBCONTRACTORS, MATERIAL SUPPLIERS, LESSEES AND PROPERTY OWNERS THAT THE DISCHARGE OF POLLUTANTS INTO THE STORM DRAIN SYSTEM OR OTHER WATERSHED DRAINAGE FEATURES IS PROHIBITED. 45.DEWATERING OF CONTAMINATED GROUNDWATER OR DISCHARGING CONTAMINATED SOILS VIA SURFACE EROSION IS PROHIBITED. DEWATERING OF NON -CONTAMINATED GROUNDWATER REQUIRES A NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM PERMIT FROM THE RESPECTIVE STATE REGIONAL WATER QUALITY CONTROL BOARD. 46. PRIOR TO CONSTRUCTION, ALL SURVEY MONUMENTS AND CENTERLINE TIES ARE TO BE LOCATED IN THE FIELD. UPON COMPLETION OF CONSTRUCTION, ALL DAMAGED OR DESTROYED CENTERLINE TIES AND SURVEY MONUMENTS ARE TO BE RESET AND "CORNER RECORDS" PREPARED FOR SURVEY MONUMENTS FOR SUBMISSION TO THE CITY'S ENGINEERING DIVISION AND FILING WITH THE COUNTY SURVEYOR IN COMPLIANCE WITH AB1414. THIS MUST BE COMPLETED PRIOR TO CERTIFYING COMPLETION OF THE PROJECT. ALL RESTORATIONS OF SURVEY MONUMENTS SHALL BE CERTIFIED BY THE DESIGN REGISTERED ENGINEER IN ACCORDANCE WITH SECTION 8771 OF THE BUSINESS AND PROFESSIONS CODE. 47.A CITY OF NEWPORT BEACH ENCROACHMENT PERMIT WILL BE REQUIRED PRIOR TO ANY GRADING OR WORK IN CITY'S PUBLIC RIGHT-OF-WAY. bt:Aurlp UA ENGINEER'S NOTICE TO CONTRACTORS THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY SEARCH OF AVAILABLE RECORDS AND TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT FOR THOSE SHOWN ON THIS PLAN. THE CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN, AND ANY OTHER LINES OR STRUCTURES NOT SHOWN IN THESE PLANS, AND IS RESPONSIBLE FOR PROTECTION OF AND ANY DAMAGE TO THESE LINES OR STRUCTURES. CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTACTORS WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION ON THIS PROJECT. INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO, DEFEND, INDEMNIFY AND HOLD DESIGN PROFESSIONAL AND OWNER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPORTING ANY DISCREPANCIES IN PLANS AND OR FIELD CONDITIONS IMMEDIATELY TO THE DESIGN ENGINEER FOR RESOLUTION PRIOR TO CONSTRUCTION, AND SHALL BE RESPONSIBLE FOR DISCREPANCIES NOT SO REPORTED AND RESOLVED. CAUTION: THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR, OR LIABLE FOR, UNAUTHORIZED CHANGES OR USES OF THESE PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND MUST BE APPROVED BY THE PREPARER OF THESE "PLANS". LEGAL DESCRIPTION: PROJECT ADDRESS: LOT 1 OF BLOCK 7 OF EAST NEWPORT TRACT III zsih blKtti NEWPORT BEACH, CA ASSESSOR PARCEL NUMBER SITE INFORMATION: APN: 047-282-12 AREA OF DISTURBANCE: AREA OF DISTURBANCE= 3,039 +/- SF EARTHWORK OWNER: CHRIS BENGTSON 111 8TH STREET NEWPORT BEACH, CA ARCHITECT: ARCHITECTURE JAY S. CRAWFORD CONTACT: JAY CRAWFORD, AIA 470 WALD IRVINE, CA 92618 (949) 453-9893 JAY®CRAWFORDARCHITECTURE.COM SURVEYOR: ROM SURVEYING, INC CONTACT: RON MIEDEMA L.S. 4653 23016 LAKE FOREST DRI. #409 LAGUNA HILLS, CA 92653 (949) 858-2924 RDMSURVEYINGOCOX.NET GEOTECH: COLEMAN GEOTECHNICAL CONTACT: LEE SHOEMAKER 470 WALD IRVINE, CA 92618 (949)872-2582 DISTURBED AREA = 3,039 SF EXISTING IMPERVIOUS = 2,539 SF PROPOSED IMPERVIOUS = 2,500 SF DEMOLITION NOTES: 2 LOW IMPACT DEVELOPMENT: BELOW IS A LIST OF LOW IMPACT DEVELOPMENT (LID) BEST MANAGEMENT PRACTICES (BMP) PROPOSED FOR THIS PROJECT. LID BMP NO. 1 - RUNOFF FROM IMPERMEABLE AREAS DIRECTED TO PERMEABLE AREAS LID BMP NO. 2 - PERMEABLE PAVERS WILL BE USED FOR HARDSCAPE. LID BMP NO. 3 - UNDERGROUND INFILTRATION CHAMBER acrvc. L=J " ..GNC. ❑1 SAW CUT AND DEMO EXISTING ASPHALT 7 DEMO EXISTING STRUCTURE 3❑ DEMO EXISTING HARDSCAPE AND LANDSCAPING CONC. CON:;. EXISTING SITE COND4T40NS AND DEMO PLAN SCALE: 1"= 8' 0' 8' 16' 24' a 2 Z W J cn z Zy 0 �o R CUC,A� O O< O U w J Z Z H W O Z ~� 0 N Z¢ o! w a 0 U) z 0 F_ a U w 0 CUT = 10 YDS u a 4.` b FILL = 0 YDS V EXPORT = 10 YDS GRADING RECOMMENDATIONS FROM GEOTECH: 0 m mn a *THE EARTHWORK NUMBERS THE FOLLOWING SPECIAL GRADING PROVISIONS ARE RECOMMENDED FOR THE GRADING OF THIS PROJECT IN ABOVE ARE ESTIMATES. ADDITION TO THE GRADING SPECIFICATIONS, GENERAL PROVISIONS INCLUDED IN THE APPENDIX OF THIS ACTUAL EARTHWORK TO BE REPORT. DETERMINED BY CONTRACTOR. 1. THE CONSTRUCTION MAY INCLUDE RETAINING OR GARDEN WALLS WHICH MAY OR MAY NOT BE SHOWN ON >7,w <0 THE CURRENTLY AVAILABLE PLANS. SUCH WALLS SHOULD BE CONSIDERED AS PART OF THE STRUCTURES omOIro¢ TO BE CONSTRUCTED, AND FOUNDATION DESIGN, CONSTRUCTION, AND GRADING RECOMMENDATIONS O� z 0 PRESENTED IN THIS REPORT SHOULD APPLY TO THESE WALLS AS IF THEY WERE PART OF THE BUILDING. C7 rn ¢ 2. THE NATURAL SOILS IN AREAS TO RECEIVE FILL OUTSIDE THE BUILDING PADS SUCH AS HARDSCAPE Ln D N� �} AREAS SHALL BE SCARIFIED AND COMPACTED TO A DEPTH OF 12 INCHES BELOW THE EXISTING SURFACE AFTER CLEARING AND GRUBBING. Z 3. ANY VOIDS CREATED DURING THE REMOVAL OF THE EXISTING HOME, FOUNDATION, EXISTING UTILITY LINES OR ROOTS WILL NEED TO BE PROPERLY EXCAVATED AND BACKFILL WITH COMPACTED SOILS AS 0 cn PART OF THE SITE GRADING. 4. SHORING MUST BE PROVIDED PRIOR TO OVEREXCAVATION OF THE LOT. RECOMMENDED SHORING �.............. PROCEDURES/METHOD ARE PROVIDED IN SECTION 5.7.1 OF THIS REPORT. A= 5. ONCE SHORING IS IN PLACE, THE EXISTING SOILS BELOW THE BUILDING PAD AND HARDSCAPE AREAS a a SHALL BE OVEREXCAVATED TO A DEPTH OF 36 INCHES BELOW EXISTING GRADE AND THE RESULTING Z I 0 SURFACE SCAR IF I ED/RECOMPACTED TO A DEPTH OF 12 INCHES PRIOR TO REPLACING WITH SOIL -CEMENT F COMPACTED FILL. SOIL -CEMENT WILL INCREASE THE COHESION AND WORKABILITY OF THE SOILS. W PORTLAND CEMENT SHALL BE ADDED AND BLENDED INTO THE SOILS IN A RATIO OF 2 SACK CEMENT PER y ONE CUBIC -YARD OF SOIL. THE STIFFENED SOIL WILL REDUCE CAVING POTENTIAL OF THE SOILS WHICH WILL ALLOW THE FOOTING EXCAVATION TO REMAIN NEAT AND SQUARE UPON EXCAVATION. SOIL - Z ¢a CEMENT WILL ALSO CREATE A RIGID SOIL MASS SIGNIFICANTLY MORE RESISTANT TO THE EFFECTS OF ." a .k 3 LIQUEFACTION AND SEISMIC SETTLEMENT. 6. ALL SCARIFICATION AND REMOVALS SPECIFIED HEREIN SHALL EXTEND TO A DISTANCE OF AT LEAST 2 FEET BEYOND ALL FOOTING, BUILDING, AND HARDSCAPE EDGES UNLESS PROPERTY LINE OR OTHER �� CONSTRAINTS EXIST. SPECIAL RECOMMENDATIONS WILL BE PRESENTED DURING GRADING FOR GRADING IN m THOSE AREAS WHERE CONSTRAINTS ARE PRESENT. 7. SOIL UTILIZED FOR FILLING SHALL CONSIST OF APPROVED ON-SITE OR IMPORTED SOIL. ON-SITE SOILS WHICH ARE FREE OF TRASH, DEBRIS, AND ORGANIC MATERIALS CAN BE CONSIDERED AS SUITABLE. 8. ANY IMPORTED SOIL SHALL BE APPROVED BY THE SOIL ENGINEER FOR BOTH EXPANSIVE AND STRENGTH a }q� QUALITIES PRIOR TO IMPORTATION TO THE PROJECT SITE. FINAL ACCEPTANCE OF ANY IMPORTED SOIL WILL BE BASED ON OBSERVATION OF THE SOIL ACTUALLY DELIVERED TO THE SITE. 9. ALL FILL SHALL BE COMPACTED TO AT LEAST 90 PERCENT RELATIVE COMPACTION. 10. THE MAXIMUM DENSITY OF ALL SOILS SHALL BE DETERMINED IN ACCORDANCE WITH A.S.T.M. TEST METHOD D-1557. THE MAXIMUM DENSITY OF AGGREGATE BASE SHALL BE DETERMINED IN ACCORDANCE WITH A. CALIFORNIA TEST METHOD 216. 11. THE SOIL PLACED IN THE UPPER 12 INCHES OF THE STRUCTURE AND HARDSCAPE AREAS SHALL BE PLACED AT A MOISTURE CONTENT OF AT LEAST 1-2 PERCENT ABOVE OPTIMUM MOISTURE CONTENT IF EXISTING ON-SITE OR SIMILAR SOILS ARE USED. IF SIGNIFICANT DRYING OCCURS PRIOR TO SLAB OR HARDSCAPE .. PLACEMENT, MOISTURE CONDITIONING OF THE SLAB AREA BY FLOODING OR OTHER MEANS MAY BE NEEDED PRIOR TO SLAB PLACEMENT. 12. ALL OTHER FILL SHALL BE PLACED WITH A MOISTURE CONTENT OF OPTIMUM OR GREATER. 13. ALL GRADING PLANS SHALL BE FORWARDED TO THE SOIL ENGINEER FOR REVIEW AND COMMENT PRIOR TO THE START OF CONSTRUCTION. CONTACT INFO: OWNER: CHRIS BENGTSON 111 8TH STREET NEWPORT BEACH, CA ARCHITECT: ARCHITECTURE JAY S. CRAWFORD CONTACT: JAY CRAWFORD, AIA 470 WALD IRVINE, CA 92618 (949) 453-9893 JAY®CRAWFORDARCHITECTURE.COM SURVEYOR: ROM SURVEYING, INC CONTACT: RON MIEDEMA L.S. 4653 23016 LAKE FOREST DRI. #409 LAGUNA HILLS, CA 92653 (949) 858-2924 RDMSURVEYINGOCOX.NET GEOTECH: COLEMAN GEOTECHNICAL CONTACT: LEE SHOEMAKER 470 WALD IRVINE, CA 92618 (949)872-2582 DISTURBED AREA = 3,039 SF EXISTING IMPERVIOUS = 2,539 SF PROPOSED IMPERVIOUS = 2,500 SF DEMOLITION NOTES: 2 LOW IMPACT DEVELOPMENT: BELOW IS A LIST OF LOW IMPACT DEVELOPMENT (LID) BEST MANAGEMENT PRACTICES (BMP) PROPOSED FOR THIS PROJECT. LID BMP NO. 1 - RUNOFF FROM IMPERMEABLE AREAS DIRECTED TO PERMEABLE AREAS LID BMP NO. 2 - PERMEABLE PAVERS WILL BE USED FOR HARDSCAPE. LID BMP NO. 3 - UNDERGROUND INFILTRATION CHAMBER acrvc. L=J " ..GNC. ❑1 SAW CUT AND DEMO EXISTING ASPHALT 7 DEMO EXISTING STRUCTURE 3❑ DEMO EXISTING HARDSCAPE AND LANDSCAPING CONC. CON:;. EXISTING SITE COND4T40NS AND DEMO PLAN SCALE: 1"= 8' 0' 8' 16' 24' a 2 Z W J cn z Zy 0 �o R CUC,A� O O< O U w J Z Z H W O Z ~� 0 N Z¢ o! w a 0 U) z 0 F_ a U w 0 �X m a 0 u a 4.` b U V W a:0 W DU s_ 0 m mn a 110 rn UJ ZZ`�m3� M F- ¢ Z W CO >7,w <0 ¢� LLJ omOIro¢ W O� z 0 m C7 rn ¢ W Ln D N� �} s t' �X e b. u a 4.` b 0 V V N_ s_ V a .. 'aW ZZ`�m3� <o CO W ¢� LLJ m N gg (� ............ e, s t' Z00 MF Z 3^ww 0 cn = �.............. A= co a a Z I 0 F W O;.. y c kn 0 co Z ¢a 2jgj►•ijj@jmIj C-1 31 z, W _ V ante: s_ V mom `aQ F o W ZZ`�m3� <o CO W ¢� LLJ m z, 6 gg (� Z00 MF k 3^ww 0 cn = co Z I 0 fl (� W n c kn ." a .k 3 .. tib` & a-`.. W O J �� m < b 0 tqY a }q� f A. .. b� C) bN H k LA- (10 LY 0 JOB NUMBER: BENCH MARK: 100904 ontE: 9/5/2017 BENCH MARK #1 IE -122-14 SHEET NO: NAVD88 2jgj►•ijj@jmIj C-1 31 w ry O ¢ z On ¢ „ LL_ L LL m 0.iZ o C-4 M 5 5 43' :A 9.90 TG o 6 �O, C V c T PIPE z"' B, 8.9u'1NV :. ...... VENT PIPE a6 J � w J J w O m z. I— V) w I H w m O F - LL_ U' 9.90 TG >- 9.10 INV 6 PRELIMINARY PRECISE GRADING PLAN FF =10.50 PAD = 9.50 PRELIMINARY PRECISE GRADING PLAN 0' 4' 8' 12' SCALE: 1" = 4' 8.951NV CONSTRUCTION NOTES: �1 CONSTRUCT MASONRY WALL PER LANDSCAPE PLANS AND DETAILS. O2 CONSTRUCT MASONRY LOW PILASTER PER LANDSCAPE PLANS AND DETAILS. O3 CONSTRUCT PERMEABLE INTERLOCKING CONCRETE PAVING PER LANDSCAPE PLANS AND DETAILS. O4 CONSTRUCT INTERLOCKING CONCRETE STEPS PER LANDSCAPE PLANS AND DETAILS. O5 PLANTED LANDSCAPE AREA PER LANDSCAPE PLANS AND DETAILS. O6 INSTALL 3" ROUND BRASS GRATE INLET (NDS 15BR) W/ RISER AND ADAPTOR OR EQUAL. O7 INSTALL 6" FLAT DRAIN (NDS TYPE 40) W/ RISER AND ADAPTOR OR EQUAL. ( INSTALL 4" SCH 40 PVC AREA DRAIN LINE 9O INSTALL PRIVATE DRAIN THROUGH CURB PER CITY OF NEWPORT BEACH STD -184-L. 10 INSTALL CONTECH CHAMBERMAXX OPEN -BOTTOM INFILTRATION W/ START, MIDDLE AND END SECTIONS 11 CONSTRUCT DEEPENED FOOTING. DEPTHS (D) PER PLAN. 12 INSTALL 4" OF DECOMPOSED GRANITE OVER 6" OF COMPACTED CLASS II ROAD BASE. m n n00 0 Z w� (nZ �o 0 U oa Z=w U � a Z win w Dj O pa cn z c w may' PUBLIC WORKS CONSTRUCTION NOTES: O ' 15 RECONSTRUCT ALLEY APPROACH PER CITY OF NEWPORT BEACH STD -142-L. V) 16 PLUG EXISTING DRIVEWAY PER CITY OF NEWPORT BEACH STD -165-L. RECONSTRUCT CURB RAMP TO BE ADA COMPLIANT PER CITY OF NEWPORT BEACH STD -181 -L -B, CASE °J". w o rx C��Ca �, u: 18 INSTALL SEWER CLEAN OUT PER CITY OF NEWPORT BEACH STD -406-L. cj� a aW41N {17 o 50 UTILITY NOTE: 601NV 7 1. ALL WORK RELATED TO WATER IN THE PUBLIC RIGHT-OF-WAY SHALL BE PERFORMED BY A C-34 5 c3 LICENSED PIPELINE CONTRACTOR OR AN A LICENSED GENERAL ENGINEERING CONTRACTOR. 4� acs kca > 2. ALL WORK RELATED TO WASTEWATER IN THE PUBLIC RIGHT-OF-WAY SHALL BE PERFORMED BY A o f C-42 LICENSED SANITATION SEWER CONTRACTOR OR A LICENSED GENERAL ENGINEERING 8.50 INV CONTRACTOR. DISCHARGE FROM CHAM R N m O w 0-0 _...._L. ._ 8.5 vINV r,, . ..« O INLET TO , AMBER „ n O Dd'N U_j F......i.. ...Y . W d'HQUJI Z WJ 0 .a N C7Z UU E..L..,Tp..,' 1...... 0 4 . i; -I O2 Z W CL Z . (n 9.70 FIG = w wOZn< mw FL .._ 1 00 w > LO w N < 1' 3' a ar�i 0)v~i (9.21FS) Y" T !i ePR MASONRY LEGEND 1 <. tiGc WALL W a EP EDGE OF PAVEMENT ESMT EASEMENT w EX r EXISTING 2% MIN Q FF FINISHED FLOOR J, FG FINISHED GRADE EX FS FL FLOW LIN MIN E O :a FF 10. 5 .... �o „ FS FINISHED SURFACE a x c GB GRADE BREAK x4.P HP HIGH POINT NLE,T TO CHAfGiBER �a - LP LOW POINT 8.60 INV MAX MAXIMUM 1 0 FS N `" MIN MINIMUM N O (10.45 FS) i .., PUE PUBLIC UTILITY ESMT PL PROPERTY LINE SECTION A -A z o 9.50 TG rt'= " R W RIGHT OF WAY SCALE: 1 = 4 z 8.7 INV SD STORM DRAIN w a Z `,...E., ". TC TOP OF CURB Z U' r O 12 <t.: TS TOP OF SLOPE O z v - H z c TYP TYPICAL N w (j EE AIR CONDITIONER ~ p w Z �-cU ELECTRIC METER ; p ¢ o w W ZgZV)w3 m c iw IRRIGATION CONTROL VALVE W ¢ x m w j Fel `, �G' cep: GAS METER �' m � C7 � � Z $ vi 00 '" � �4 ® WATER METER co 0 v~i ] _ _ as v cvy . WATER VALVE s w V --i , PROJECT BOUNDARY FL = 0 z xo H F t;, `'. — ss — EXISTING SANITARY SEWER U w 3 1 �4' ;�------ G® '• ------ oav ------ EXISTING DOMESTIC WATER I'n SOI SD --- EXISTING STORM DRAIN LINE w 0 0HE— EXISTING OVER HEAD ELEC. c ----'I - EXISTING CONTOUR PR MASONRY a —1630— PROPOSED CONTOUR 0 h PROPERTY LINE F ---- RIGHT OF WAY of s. - - - - - EXISTING EASEMENT 2% MIN k '` " PROPOSED CURB EX FS PROPOSED AREA DRAIN PIPE 27 10 r " 0 EXISTING CHAIN LINK FENCE FF=10 5Q MIN Al EXISTING WOOD FENCE -~ U (( V V) " PROPOSED DRAINAGE SWALE Q�OVESS/Oy `. Y JOB NUMBER: cv0 EDEN q ql� ;. < — PROPOSED CONCRETE V -DITCH x 'p 100904 PROPOSED RETAINING WALL 10. DATE $ 9/5/2017 m No. 68795 _ EXISTING RETAINING WALL ( 8.95 FS) SHEET No, �C Exp 9-30-2019 *:...=,__- PROPOSED CONCRETE EXISTING CONCRETE SECTION B -B TgTf0F CAI�SCALE: 1" = 4' S2 <: T FF =10.50 PAD = 9.50 PRELIMINARY PRECISE GRADING PLAN 0' 4' 8' 12' SCALE: 1" = 4' 8.951NV CONSTRUCTION NOTES: �1 CONSTRUCT MASONRY WALL PER LANDSCAPE PLANS AND DETAILS. O2 CONSTRUCT MASONRY LOW PILASTER PER LANDSCAPE PLANS AND DETAILS. O3 CONSTRUCT PERMEABLE INTERLOCKING CONCRETE PAVING PER LANDSCAPE PLANS AND DETAILS. O4 CONSTRUCT INTERLOCKING CONCRETE STEPS PER LANDSCAPE PLANS AND DETAILS. O5 PLANTED LANDSCAPE AREA PER LANDSCAPE PLANS AND DETAILS. O6 INSTALL 3" ROUND BRASS GRATE INLET (NDS 15BR) W/ RISER AND ADAPTOR OR EQUAL. O7 INSTALL 6" FLAT DRAIN (NDS TYPE 40) W/ RISER AND ADAPTOR OR EQUAL. ( INSTALL 4" SCH 40 PVC AREA DRAIN LINE 9O INSTALL PRIVATE DRAIN THROUGH CURB PER CITY OF NEWPORT BEACH STD -184-L. 10 INSTALL CONTECH CHAMBERMAXX OPEN -BOTTOM INFILTRATION W/ START, MIDDLE AND END SECTIONS 11 CONSTRUCT DEEPENED FOOTING. DEPTHS (D) PER PLAN. 12 INSTALL 4" OF DECOMPOSED GRANITE OVER 6" OF COMPACTED CLASS II ROAD BASE. m n n00 0 Z w� (nZ �o 0 U oa Z=w U � a Z win w Dj O pa cn z c w may' PUBLIC WORKS CONSTRUCTION NOTES: O ' 15 RECONSTRUCT ALLEY APPROACH PER CITY OF NEWPORT BEACH STD -142-L. V) 16 PLUG EXISTING DRIVEWAY PER CITY OF NEWPORT BEACH STD -165-L. RECONSTRUCT CURB RAMP TO BE ADA COMPLIANT PER CITY OF NEWPORT BEACH STD -181 -L -B, CASE °J". w o rx C��Ca �, u: 18 INSTALL SEWER CLEAN OUT PER CITY OF NEWPORT BEACH STD -406-L. cj� a aW41N {17 o 50 UTILITY NOTE: 601NV 7 1. ALL WORK RELATED TO WATER IN THE PUBLIC RIGHT-OF-WAY SHALL BE PERFORMED BY A C-34 5 c3 LICENSED PIPELINE CONTRACTOR OR AN A LICENSED GENERAL ENGINEERING CONTRACTOR. 4� acs kca > 2. ALL WORK RELATED TO WASTEWATER IN THE PUBLIC RIGHT-OF-WAY SHALL BE PERFORMED BY A o f C-42 LICENSED SANITATION SEWER CONTRACTOR OR A LICENSED GENERAL ENGINEERING 8.50 INV CONTRACTOR. DISCHARGE FROM CHAM R N m O w 0-0 _...._L. ._ 8.5 vINV r,, . ..« O INLET TO , AMBER „ n O Dd'N U_j F......i.. ...Y . W d'HQUJI Z WJ 0 .a N C7Z UU E..L..,Tp..,' 1...... 0 4 . i; -I O2 Z W CL Z . (n 9.70 FIG = w wOZn< mw FL .._ 1 00 w > LO w N < 1' 3' a ar�i 0)v~i (9.21FS) Y" T !i ePR MASONRY LEGEND 1 <. tiGc WALL W a EP EDGE OF PAVEMENT ESMT EASEMENT w EX r EXISTING 2% MIN Q FF FINISHED FLOOR J, FG FINISHED GRADE EX FS FL FLOW LIN MIN E O :a FF 10. 5 .... �o „ FS FINISHED SURFACE a x c GB GRADE BREAK x4.P HP HIGH POINT NLE,T TO CHAfGiBER �a - LP LOW POINT 8.60 INV MAX MAXIMUM 1 0 FS N `" MIN MINIMUM N O (10.45 FS) i .., PUE PUBLIC UTILITY ESMT PL PROPERTY LINE SECTION A -A z o 9.50 TG rt'= " R W RIGHT OF WAY SCALE: 1 = 4 z 8.7 INV SD STORM DRAIN w a Z `,...E., ". TC TOP OF CURB Z U' r O 12 <t.: TS TOP OF SLOPE O z v - H z c TYP TYPICAL N w (j EE AIR CONDITIONER ~ p w Z �-cU ELECTRIC METER ; p ¢ o w W ZgZV)w3 m c iw IRRIGATION CONTROL VALVE W ¢ x m w j Fel `, �G' cep: GAS METER �' m � C7 � � Z $ vi 00 '" � �4 ® WATER METER co 0 v~i ] _ _ as v cvy . WATER VALVE s w V --i , PROJECT BOUNDARY FL = 0 z xo H F t;, `'. — ss — EXISTING SANITARY SEWER U w 3 1 �4' ;�------ G® '• ------ oav ------ EXISTING DOMESTIC WATER I'n SOI SD --- EXISTING STORM DRAIN LINE w 0 0HE— EXISTING OVER HEAD ELEC. c ----'I - EXISTING CONTOUR PR MASONRY a —1630— PROPOSED CONTOUR 0 h PROPERTY LINE F ---- RIGHT OF WAY of s. - - - - - EXISTING EASEMENT 2% MIN k '` " PROPOSED CURB EX FS PROPOSED AREA DRAIN PIPE 27 10 r " 0 EXISTING CHAIN LINK FENCE FF=10 5Q MIN Al EXISTING WOOD FENCE -~ U (( V V) " PROPOSED DRAINAGE SWALE Q�OVESS/Oy `. Y JOB NUMBER: cv0 EDEN q ql� ;. < — PROPOSED CONCRETE V -DITCH x 'p 100904 PROPOSED RETAINING WALL 10. DATE $ 9/5/2017 m No. 68795 _ EXISTING RETAINING WALL ( 8.95 FS) SHEET No, �C Exp 9-30-2019 *:...=,__- PROPOSED CONCRETE EXISTING CONCRETE SECTION B -B TgTf0F CAI�SCALE: 1" = 4' S2 i "" WM 1 GRA BAG BERM (SEl r —-------- ;i i o WM-8 IQ u I � < 1 .. Y G Q ' (9,6Z S) ...... ..... ............................... STREET S EEP I NG (TYP) (SE -7) Z, I `"I 6.: 1 a� WmI I C� V W (,v ql {VZX 9 f - I . DIG T DIAL TOLL FREE 1(800) 227-2600 t Least Two Working Days Before You Dig UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA Q 10.14FS F Nlz�; SILT FENCE (TYP) PRELIMINARY EROSION CONTROL PLAN 0' 4' 8' 12' SCALE: 1" = 4' v i THE FOLLOWING BEST MANAGEMENT PRACTICES ARE TO BE ABIDED WITH IN ACCORDANCE TO THE LATEST CALIFORNIA STORMWATER QUALITY ASSOCIATION BEST MANAGEMENT PRACTICES HANDBOOK ("CASQA BMP HANDBOOK") —o --o— SE -1 SILT FENCE PER CASQA BMP HANDBOOK DETAILS SE -6 GRAVEL BAG BERM (3 HIGH W/ 3:2:1 STACKING) v PER CASQA BMP HANDBOOK SE -10 STORM DRAIN INLET PROTECTION PER CASQA BMP HANDBOOK TC -1 TEMPORARY CONSTRUCTION ENTRANCE WITH 3" T06" ROCK OVER FILTER FABRIC DEPTH=8" PER CASQA BMP HANDBOOK EC -7 GEOTEXTILES AND MATS (JUTE NETTING) SE -7 STREET SWEEPING WM-3 STOCKPILE MANAGEMENT PER CASQA BMP HANDBOOK WM-1 WM-1 MATERIAL DELIVERY AND STORAGE PER CASQA BMP HANDBOOK WIM-8 WM-8 TEMPORARY CONCRETE WASHOUT PER CASQA BMP HANDBOOK WM-9 WM-9 SANITARY MANAGEMENT (PORTABLE TOILET) nCC No. 68795 Exp s-3o-2oys *� r 4 a Z 3 J O N Z Zlz N O OF O K UU OO¢ OU inl ZN W Ot7) O OO N Z W 9 m a O U ui a. p Z� co J 0 w U J Z J OZUzOVU Jg_jaz0 0 0001 00 W W 0 Z n a z U z MUJ @ a LU §N .- > c7 v 0)W EL Q M J mco _ W a U D Zm o: QJ U a Z O i�Z LLJ WItUK Z00 m W l 3: m sac: 00 Of Ji 0-00 = ZUj V sp O ,n " J W (� M U 6 O —o --o— SE -1 SILT FENCE PER CASQA BMP HANDBOOK DETAILS SE -6 GRAVEL BAG BERM (3 HIGH W/ 3:2:1 STACKING) v PER CASQA BMP HANDBOOK SE -10 STORM DRAIN INLET PROTECTION PER CASQA BMP HANDBOOK TC -1 TEMPORARY CONSTRUCTION ENTRANCE WITH 3" T06" ROCK OVER FILTER FABRIC DEPTH=8" PER CASQA BMP HANDBOOK EC -7 GEOTEXTILES AND MATS (JUTE NETTING) SE -7 STREET SWEEPING WM-3 STOCKPILE MANAGEMENT PER CASQA BMP HANDBOOK WM-1 WM-1 MATERIAL DELIVERY AND STORAGE PER CASQA BMP HANDBOOK WIM-8 WM-8 TEMPORARY CONCRETE WASHOUT PER CASQA BMP HANDBOOK WM-9 WM-9 SANITARY MANAGEMENT (PORTABLE TOILET) nCC No. 68795 Exp s-3o-2oys *� r 4 a Z 3 J O N Z Zlz N O OF O K UU OO¢ OU inl ZN W Ot7) O OO N Z W 9 m a O U ui a. p Z� co J 0 w U J Z J OZUzOVU Jg_jaz0 0 0001 00 W W 0 Z n a z U z MUJ @ a LU §N .- > c7 v 0)W EL Q M J mco _ W a U D Zm o: QJ U a Z O i�Z LLJ WItUK Z00 m W l 3: m sac: 00 Of Ji 0-00 = ZUj V i O J W (� M U 6 O m 0 0 J W S S Of V W 6 Of JOB NUMBER: 100904 DATE: 9/5/2017 Memorandum Zoning Administrator - October 12, 2017 ITEM NO. la - ADDITIONAL MATERIALS RECEIVED Bengtson Residence Coastal Development Permit CITY OF NE'. 'T BEACH COMMUNITYDEVELOPR' -'ENT 100 Civic Center Drive Newport Beach, California 92660 949 644-3200 newportbeachca.gov/communitydevelopment To: Patrick Alford, Zoning Administrator From: Gregg Ramirez, Senior Planner Date: October 10, 2017 Re: Bengtson Residence CDP - Remove from Agenda Agenda Item No. 1 (PA2017-058) Staff requests that this item be removed from the aganda. The project is being re- designed to ensure the proposed home complies with applicable development standards. Public notice will be provided in accordance with the Newport Beach Municipal Code when a new hearing date is scheduled. To: ZONING ADMINISTRATOR - OCTOBER 12, 2017 Subject: ADDITIONAL MATERIALS RECEIVED • ITEM III - DRAFT MINUTES OF 09/28/2017 •ITEM 1b - engston Residence CDP (PA2017-058) b - Rooney Residence CDP (PA2017-029) From: Jim Mosher [mailto:iimmosher@yahoo.com] Sent: Thursday, October 12, 2017 12:57 PM To: Alford, Patrick <PAlford@newportbeachca.eov> Subject: Comments on Zoning Administrator Agenda (October 12, 2017) Patrick, The City has once again scheduled its Finance Committee meeting to overlap the Zoning Administrator hearing. So I don't expect to be able to attend, but I do have these comments: Item 111.1. Minutes of September 28, 2017: page 1, Item B: the first sentence says "Gregg Ramirez, Senior Planner, requested that this item be continued..." without identifying what item. Shouldn't it say "Gregg Ramirez, Senior Planner, requested that Item 1 be continued..."? I would also note that this request was likely accompanied by a written memo. However, none of the materials related to the presentation of this Item 1 from September 28, including the continuation notice, if any, have, at present, been preserved in the City's archive of the Zoning Administrator hearings that day: http://ecros.newportbeachca.gov/Web/O/fol/l 231481 /Rowl .aspx I would suggest all the materials presented at the September 28 hearing be posted there, so both the City and the public have a complete and accurate record of what transpired. Item IVA engston Residence Coastal Development Permit No. CD2017-024: The latest request for continuance/tabling of this item says "The project is being re -designed to ensure the proposed home complies with applicable development standards." The fact that there may be doubt about the project's compliance is in curious juxtaposition to the "Project Summary" in the main staff report, which assures the Zoning Administrator and public that (as already designed) "The project complies with all applicable development standards." This vacillation, especially without any explanation of what, specifically, the compliance doubt is about, raises serious questions about the credibility of such assertions in future staff reports and Zoning Administrator resolutions. Item IV.3. Rooney Residence Coastal Development Permit No. CD2017-012: I think there is a Coastal Act issue, unaddressed here, related to the depletion of the already limited single family coastal housing stock created by the merging of the few coastal lots on which such housing is allowed. But judging from the staff report, that ship sailed when the merger underlying this out -sized development was approved on July 28, 2016. Yours sincerely, Jim Mosher