HomeMy WebLinkAbout01_1045 West Balboa Coastal Development Permit_PA2017-1834"0
CITY OF NEWPORT BEACH
ZONING ADMINISTRATOR STAFF REPORT
November 16, 2017
AgAgenda Item No. 1
SUBJECT: 1045 West Balboa CDP (PA2017-183)
SITE LOCATION: 1045 West Balboa Boulevard
• Coastal Development Permit No. CD2017-078
APPLICANT: FoxLin Architects
OWNER: Pack Investment Group, LLC
PLANNER: David S. Lee, Planning Technician
949-644-3225, dlee@newportbeachca.gov
GENERAL PLAN/ZONING DISTRICT
• Coastal Land Use Category: Two -Unit Residential— (20.0 - 29.9 DU/AC) (RT -D)
• Coastal Zoning District: Two -Unit Residential (R-2)
• General Plan Land Use Category: Two -Unit Residential (RT)
• Zoning District: Two -Unit Residential (R-2)
PROJECT SUMMARY
A request for a Coastal Development Permit (CDP) to allow the demolition of four residential
apartment units and the construction of a new 3,467 -square -foot duplex with a 643 -square -
foot attached garage and two covered carports. The proposed development also includes
additional appurtenances such as walls, fences, patios, hardscape, drainage devices, and
landscaping.
RECOMMENDATION
1) Conduct a public hearing;
2) Find this project exempt from the California Environmental Quality Act (CEQA)
pursuant to Section 15303 under Class 3 (New Construction or Conversion
of Small Structures), because it has no potential to have a significant
effect on the environment; and
3) Adopt Draft Zoning Administrator Resolution No. approving Coastal
Development Permit No. CD2017-078 (Attachment No. ZA 1).
1
1045 West Balboa CDP
Zoning Administrator, November 16, 2017
Page 2
Land Use and Development Standards
The property is located in the R-2 Coastal Zoning District, which provides for two -unit
residential development and is consistent with the City's Coastal Land Use Plan, General
Plan Land Use Category and Zoning Code. These designations also provide for two -unit
residential development. The property is located within the appeal area providing the
possibility for a final action to be appealed to the California Coastal Commission.
Additionally, a waiver for de minimis development cannot be issued because the site is
within the appeal area.
The property is developed with two structures containing two units each (four units total),
which will be demolished. The design, bulk, and scale of the proposed new duplex is
consistent with the existing neighborhood pattern of development and expected future
development.
The proposed duplex and accessory structures conform to all applicable development
standards including floor area limit, setbacks, height, 9.0 feet (NAVD88) minimum
finished floor elevation, and off-street parking as illustrated in Table 1 below:
Table 1: Development Standards
Development Feature
Required
Proposed
Setbacks (Min.)
Front
10'-0"
10'-0"
Rear
0'
0'
Sides
T-0"
T-0"
Height (Max.)
Flat
24'
24'
Sloped
29'
29'
Floor Area Limit Max.
4,578.75 sq. ft.
4,110 sq. ft.
Parkin Min.
4 spaces
4 spaces
Hazards
The property is located in an area known for the potential of seismic activity and
liquefaction. All projects are required to comply with the California Building Code (CBC)
and Building Division standards and policies. Geotechnical investigations specifically
addressing liquefaction are required to be reviewed and approved prior to the issuance
of building permit. Permit issuance is also contingent on the inclusion of design mitigation
identified in the investigations. Construction plans are reviewed for compliance with
approved investigations and CBC prior to building permit issuance.
Tmpl[: 01/17217
2
1045 West Balboa CDP
Zoning Administrator, November 16, 2017
Page 3
• The development is set back approximately 660 feet from the mean high water line.
Due to the large distance from coastal waters, a Water Quality Management Plan
(WQMP) and a Construction Pollution Prevention Plan (CPPP) are not required. A
post -construction drainage system will be installed that includes drainage and
percolation features designed to retain dry weather and minor rain run-off on-site to
ensure the project does not impact water quality. Any water not retained on-site is
directed to the City's storm drain system.
Public Access
• The project site is not located between the nearest public road and the sea or shoreline
and the proposed project will not affect public recreation, access or views.
ENVIRONMENTAL REVIEW
This project is exempt from the California Environmental Quality Act (CEQA) pursuant to
Section 15303 under Class 3 (New Construction or Conversion of Small Structures) of the
CEQA Guidelines, California Code of Regulations, Title 14, Chapter 3, because it has no
potential to have a significant effect on the environment. The Class 3 exemption includes
the construction of limited numbers of new, small structures, including one duplex. The
exemption also allows the demolition of multi -family residential structures with up to six units.
The proposed project consists of the demolition of four residential units and the construction
of a new duplex located in the R-2 Coastal Zoning District.
PUBLIC NOTICE
Notice of this public hearing was published in the Daily Pilot, mailed to all owners of
property and residential occupants within 300 feet of the boundaries of the site (excluding
intervening rights-of-way and waterways), including the applicant, and posted on the
subject property at least 10 days before the scheduled hearing, consistent with the
provisions of the Municipal Code. Additionally, the item appeared on the agenda for this
meeting that was posted at City Hall and on the City website.
APPEAL PERIOD:
An appeal or call for review may be filed with the Director of Community Development within
14 days following the date of action. For additional information on filing an appeal, contact
the Planning Division at 949-644-3200.
TmpIC 01/17/17
3
Prepared by:
David S. Lee, fanning Technician
JM/dl
Attachments: ZA 1 Draft Resolution
ZA 2 Vicinity Map
ZA 3 Project Plans
T.pl[: 01/12/17
1045 West Balboa CDP
Zoning Administrator, November 16, 2017
Page 4
0
Attachment No. ZA 1
Draft Resolution
5
RESOLUTION NO. ZA2017-###
A RESOLUTION OF THE ZONING ADMINISTRATOR OF THE
CITY OF NEWPORT BEACH APPROVING COASTAL
DEVELOPMENT PERMIT NO. CD2017-078 FOR A NEW DUPLEX
LOCATED AT 1045 WEST BALBOA BOULEVARD (PA2017-183)
THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH HEREBY FINDS AS
FOLLOWS:
SECTION 1. STATEMENT OF FACTS.
1. An application was filed by FoxLin Architects, with respect to property located at 1045 West
Balboa Boulevard, and legally described as Lot 12 of Block 10, requesting approval of a
Coastal Development Permit.
2. The applicant proposes the demolition of four residential apartment units and the
construction of a new 3,467 -square -foot duplex with a 643 -square -foot attached garage
and two covered carports. The proposed development also includes additional
appurtenances such as walls, fences, patios, hardscape, drainage devices, and
landscaping.
3. The subject property is located within the Two -Unit Residential (R-2) Zoning District and
the General Plan Land Use Element category is Two -Unit Residential (RT).
4. The subject property is located within the coastal zone. The Coastal Land Use Plan
category is Two -Unit Residential — (20.0 - 29.9 DU/AC) (RT -D) and the Coastal Zoning
District is Two -Unit Residential (R-2).
5. A public hearing was held on November 16, 2017, in the Corona del Mar Conference Room
(Bay E -1st Floor) at 100 Civic Center Drive, Newport Beach. A notice of time, place and
purpose of the hearing was given in accordance with the Newport Beach Municipal
Code. Evidence, both written and oral, was presented to, and considered by, the Zoning
Administrator at this hearing.
SECTION 2. CALIFORNIA ENVIRONMENTAL QUALITY ACT DETERMINATION.
1. This project is categorically exempt pursuant to Title 14 of the California Code of
Regulations (Section 15315, Article 19 of Chapter 3, Guidelines for Implementation of the
California Environmental Quality Act (CEQA) under Class 3 (New Construction or
Conversion of Small Structures), because it has no potential to have a significant effect
on the environment.
2. Class 3 exempts the construction of limited numbers of new, small structures, including
one duplex. The proposed project consists of the demolition of four residential units and
the construction of a new duplex located in the R-2 Coastal Zoning District.
N
Zoning Administrator Resolution No. ZA2017-###
Pace 2 of 5
SECTION 3. REQUIRED FINDINGS.
In accordance with Section 21.52.015 (Findings and Decision) of the Newport Beach Municipal
Code, the following findings and facts in support of such findings are set forth:
Finding:
A. Conforms to all applicable sections of the certified Local Coastal Program.
Facts in Support of Finding:
The proposed development complies with applicable residential development standards
including, but not limited to, floor area limitation, setbacks, height, and parking.
a. The maximum floor area limitation is 4,578.75 square feet and the proposed floor
area is 4,110 square feet.
b. The proposed development complies with the required setbacks, which are 10
feet along the property line abutting West Balboa Boulevard and 3 feet along
each side property line. There is no required setback abutting the 20 -foot -wide
alley.
The highest guardrail/parapet is 24 feet from established grade and the highest
ridge is 29 feet from established grade. The proposed development complies with
all height requirements.
The proposed development provides a two -car garage and a two -car carport,
meeting the minimum garage requirement for duplexes.
e. The proposed development provides a finish floor elevation of 10.24 (NAVD88),
exceeding the minimum 9.0 (NAVD88) top of slab elevation requirement for
interior living areas of new structures.
2. The neighborhood is predominantly developed with two- and three-story single-family
and two-family residences. The proposed design, bulk, and scale of the development is
consistent with the existing neighborhood pattern of development and expected future
development.
3. The development is set back approximately 660 feet from the mean high water line. Due
to the large distance from coastal waters, a Water Quality Management Plan (WQMP)
and a Construction Pollution Prevention Plan (CPPP) are not required. A post -
construction drainage system will be installed that includes drainage and percolation
features designed to retain dry weather and minor rain run-off on-site to ensure the project
does not impact water quality. Any water not retained on-site is directed to the City's storm
drain system.
4. The property is located in an area known for the potential of seismic activity and
liquefaction. All projects are required to comply with the California Building Code (CBC)
01-03-17
Zoning Administrator Resolution No. ZA2017-###
Paqe 3 of 5
and Building Division standards and policies. Geotechnical investigations specifically
addressing liquefaction are required to be reviewed and approved prior to the issuance of
building permits. Permit issuance is also contingent on the inclusion of design mitigation
identified in the investigations. Construction plans are reviewed for compliance with
approved investigations and CBC prior to building permit issuance.
Finding:
B. Conforms with the public access and public recreation policies of Chapter 3 of the Coastal
Act if the project is located between the nearest public road and the sea or shoreline of any
body of water located within the coastal zone.
Fact in Support of Finding:
The project site is not located between the nearest public road and the sea or shoreline
and the proposed project will not affect public recreation, access or views.
SECTION 4. DECISION.
NOW, THEREFORE, BE IT RESOLVED:
The Zoning Administrator of the City of Newport Beach hereby approves Coastal
Development Permit No. CD2017-078, subject to the conditions set forth in Exhibit "A,"
which is attached hereto and incorporated by reference.
2. This action shall become final and effective 14 days following the date this Resolution
was adopted unless within such time an appeal or call for review is filed with the
Community Development Director in accordance with the provisions of Title 21 Local
Coastal Implementation Plan, of the Newport Beach Municipal Code. Final action taken
by the City may be appealed to the Coastal Commission in compliance with Section
21.64.035 of the City's certified LCP and Title 14 California Code of Regulations,
Sections 13111 through 13120, and Section 30603 of the Coastal Act.
PASSED, APPROVED, AND ADOPTED THIS 16TH DAY OF NOVEMBER, 2017.
Patrick J. Alford, Zoning Administrator
01-03-17
8
Zoning Administrator Resolution No. ZA2017-###
Paqe 4 of 5
EXHIBIT "A"
CONDITIONS OF APPROVAL
1. The development shall be in substantial conformance with the approved site plan, floor
plans, and building elevations stamped and dated with the date of this approval (except as
modified by applicable conditions of approval).
2. Revisions to the approved plans may require an amendment to this Coastal
Development Permit or the processing of a new Coastal Development Permit.
3. Coastal Development Permit No. CD2017-078 shall expire unless exercised within 24
months from the date of approval as specified in Section 21.54.060 (Time Limits and
Extensions) of the Newport Beach Municipal Code, unless an extension is otherwise
granted.
4. The project is subject to all applicable City ordinances, policies, and standards, unless
specifically waived or modified by the conditions of approval.
5. The applicant shall comply with all federal, state, and local laws. Material violation of
any of those laws in connection with the use may be cause for revocation of this Coastal
Development Permit.
6. This Coastal Development Permit may be modified or revoked by the Zoning
Administrator if determined that the proposed uses or conditions under which it is being
operated or maintained is detrimental to the public health, welfare or materially injurious
to property or improvements in the vicinity or if the property is operated or maintained
so as to constitute a public nuisance.
7. Prior to issuance of the building permits, a copy of the Resolution, including conditions
of approval Exhibit "A" shall be incorporated into the Building Division and field sets of
plans.
8. Prior to issuance of building permits, the applicant shall submit to the Planning Division
an additional copy of the approved architectural plans for inclusion in the Coastal
Development file. The plans shall be identical to those approved by all City departments
for building permit issuance. The approved copy shall include architectural sheets only
and shall be reduced in size to 11 inches by 17 inches. The plans shall accurately depict
the elements approved by this Coastal Development Permit.
9. Prior to the issuance of building permits, the applicant shall submit a final construction
erosion control plan. The plan shall be subject to the review and approval by the Building
Division.
10. Prior to the issuance of building permit, the applicant shall pay any unpaid administrative
costs associated with the processing of this application to the Planning Division.
01-03-17
9
Zoning Administrator Resolution No. ZA2017-###
Paqe 5 of 5
11. Should the property be sold or otherwise come under different ownership, any future
owners or assignees shall be notified of the conditions of this approval by either the
current business owner, property owner, or the leasing agent.
12. This approval shall expire and become void unless exercised within 24 months from the
actual date of review authority approval, except where an extension of time is approved in
compliance with the provisions of Title 21 Planning and Zoning of the Newport Beach
Municipal Code.
13. To the fullest extent permitted by law, applicant shall indemnify, defend and hold harmless
City, its City Council, its boards and commissions, officials, officers, employees, and agents
from and against any and all claims, demands, obligations, damages, actions, causes of
action, suits, losses, judgments, fines, penalties, liabilities, costs and expenses (including
without limitation, attorney's fees, disbursements and court costs) of every kind and nature
whatsoever which may arise from or in any manner relate (directly or indirectly) to City's
approval of 1045 West Balboa Coastal Development Permit including, but not limited to,
Coastal Development Permit No. CD2017-078 (PA2017-183). This indemnification shall
include, but not be limited to, damages awarded against the City, if any, costs of suit,
attomeys' fees, and other expenses incurred in connection with such claim, action, causes
of action, suit or proceeding whether incurred by applicant, City, and/or the parties initiating
or bringing such proceeding. The applicant shall indemnify the City for all of City's costs,
attorneys' fees, and damages which City incurs in enforcing the indemnification provisions
set forth in this condition. The applicant shall pay to the City upon demand any amount
owed to the City pursuant to the indemnification requirements prescribed in this condition.
01-03-17
10
Attachment No. ZA 2
Vicinity Map
Tmplt 01/17/17
22
VICINITY MAP
Coastal Development No. CD2017-078
PA2017-183
1045 West Balboa Boulevard
TmpIC 01/17/17
12
Attachment No. ZA 3
Project Plans
13
SYMBOLS
ABBREVIATIONS
Building Gridlines Revision Cloud & And DOU DOUBLE L LONG S SINK/SUPPLY FAN
< ANGLE DP DEMOUNTABLE PARTITION LAV LAVATORY SCHED SCHEDULE
A Revision @ AT DR DOOR LB POUND SD SHOWER DRAIN
CENTERLINE DS DOWNSPOUT LBS POUNDS (WIEGHT) SD SMOKE DAMPER
(Cloud NO. # NUMBER DW DUMBWAITER LCD LINEAR CEILING DIFFUSER SDISP SOAP DISPENSER
around 1 0 DEGREE DWG DRAWING LF LINE FIGURED SECT SECTION
Revision (E) EXISTING DWLS DOWELS LIN LINEAR SECY SECRETARY
optional) LKR LOCKER SF STORE FRONT
ABV ABOVE EA EACH LMC LINEAR METAL CEILING SF SQUARE FOOT
AB ANCHOR BOLT EC ELECTRIC CABINET LOC LOCATION OR LOCATE SH SHOWER
Window Symbol Matchline ACFL ACCESS FLOOR EF EXHAUST FAN LPT LOW POINT SHD SHOWER HEAD
Room No. Detail No. ACOUS ACOUSTICAL EI FS EXTERIOR INSULATION AND FINISH LT LIGHT SHT SHEET
�(Shaded & Sheet ACT ACOUSTICAL CEILING TILE SYSTEM LTG LIGHTING SHTG SHEATHING
1_101 AD AREA DRAIN EJT EXPANSION JOINT LVR LOUVER SIM SIMILAR
portion faces 2/A1.1 NO. ADD ADDENDUM EL ELEVATION LWC LINEAR WOOD CEILING SL SEALER
Instance No. side ADDL ADDITIONAL ELEC ELECTRICAL SLNT SEALANT
considered) ADJ ADJUSTABLE ELEV ELEVATOR M MIDDLE SLV SLEEVE
ADMIN ADMINISTRATION EMERG EMERGENCY MAN MANUAL SM SURFACE MOUNTED
AFF ABOVE FINISH FLOOR ENCL ENCLOSURE MATL MATERIAL SOG SLAB ON GRADE
Door Symbol Room Label Room AHU AIR HANDLING UNIT ENTR ENTRANCE MAX MAXIMUM SP STANDPIPE
Room No. ALT ALTERNATE EO ELECTRICAL OUTLET MBD MARKER BOARD SPEC SPECIFICATIONS
number ALUM ALUMINUM EO EQUAL MC MEDICINE CABINET SPR SINGLE PLY ROOF
101.1 Room me AMEND AMENDMENT EQUIP EQUIPMENT MECH MECHANICAL SQ SQUARE
150 SF ANUN ANUNCIATOR ES END SECTION MEMB MEMBRANE SQYD SQUARE YARD
Instance NO. AP ACCESS PANEL EWC ELECTRIC WATER COOLER MEZZ MEZZANINE SS SERVICE SINK
Room level APC ARCHITECTURAL PRECAST CONCRETE EXA EXHAUSTAIR MFR MANUFACTURER SST STAINLESS STEEL
APROX APPROXIMATE EXC EXCAVATE/ -ED/ -ION MIN MINIMUM ST STREET
ARCH ARCHITECTURAL/ARCHITECT MIR MIRROR ST STONE TILE
Detail Detail No. Section Section No. AUTO AUTOMATIC FA FIRE ALARM MISC MISCELLANEOUS STC SOUND TRANSMISSION
AWT ACOUSTICAL WALL TREATMENT FB FIRE BLANKET MO MASONRY OPENING STD STANDARD
eA101
SIM FBR FACE BRICK MONO MONOLITHIC STL STEEL
1 SIM BA BUILDING ACCESSORY FD FLOOR DRAIN MTL METAL STN STONE
BD BOARD FDN FOUNDATION MPC METAL PAN CEILING STNL STONE LEDGE
Sheet 101 BFE BOTTOM FOOTING ELEVATION FDV FIRE DEPARTMENT VALVE MPU MULTI-PURPOSE UNIT STOR STORAGE
Area Sheet No. BG BUMPER GUARD FE FIRE EXTINGUISHER MTD MOUNTED STRUCT STRUCTURAL
Reference No. BIT BITUMINOUS FGS FOAM GASKET SEAL MTR MOTOR STS STEEL STRUCTURE
d BKT BRACKET FH FIRE HOSE MULL MULLION SUPV SUPERVISOR
Elev No. Floor Level BLDG BUILDING FHP FULL HEIGHT PARTITION SUSP SUSPENDED
Exterior Elevation Floor Level BLKG BLOCKING FIN FINISH NA NOT APPLICABLE SW STEEL WINDOWS
BLW BELOW FIXT FIXTURE NIC NOT IN CONTRACT SW SWITCH
Name BM BM BEAM FL FLOOR NO NUMBER SWD SOFTWOOD
Elevation 1 BO BY OWNER FL FLOW LINE NOM NOMINAL SYM SYMMETRICAL
BOF BY OWNER FUTURE FLASH FLASHING NRC NOISE REDUCTION COEFFICIENT
Sheet NO. BOT BOTTOM FLEX FLEXIBLE NT NOTE T TOP
Elevation BR BEDROOM FLG FLANGE NTS NOT TO SCALE TAN TANGENT
BRG BEARING FLUOR FLUORESCENT TBD TACKBOARD
BSMT BASEMENT FP FIRE PROOFING OC ON CENTER TCAB TOWEL CABINET
Interior Elevation Elev No. North Arrow Project BTWN BETWEEN FRMG FRAMING OD OUTSIDE DIAMETER TDISP TISSUE DISPENSER
2 Nnorth BULL BULLETIN FS FLOOR SINK OFF OFFICE TDR TRENCH DRAIN
BUR BUILT-UP ROOFING FSTOP FIRESTOPPING OH OVERHEAD TEL TELEPHONE
The North FT FOOT/FEET OP OPERABLE PARTITION TEMP TEMPERATURE
1 A1.1 that is true C CHANNEL FTG FOOTING OPER OPERATOR TER TERRAllO
=� C DISP CUP DISPENSER FURR FURRING OPNG OPENING TG TONGUE & GROOVE
Sheet No. CAB CABINET FUT FUTURE OPP OPPOSITE THRES THRESHOLD
CANTL CANTILEVER ORD OVERFLOW ROOF DRAIN TPH TOILET PAPER HOLDER
CAP CAPACITY GA GAUGE TR TREAD
Ceiling Height Dimension String CAT CATEGORY GAL GALLONS PART PARTITION TRANSF TRANSFORMER
Ceiling CG CORNER GUARD GALV GALVANIZED PB PUSH BUTTON TS TUBE SECTION
Height CH COAT HOOK GB GRADE BEAM PC PRECAST CONCRETE TV TELEVISION
g CJT CONTROLJOINT GC GENERAL CONTRACTOR PL PLATE TYP TYPICAL
B,-0„- 01 0' - 1 1/2" CI CONSTRUCTION ISSUED GEN GENERATOR PL PROPERTY LINE
10 CLG CEILING GEN GENERAL PLAM PLASTIC LAMINATE U URINAL
CLR CLEAR GL GLASS PLBG PLUMBING UC UNDERCUT
CM CONSTRUCTION MANAGER GWA GENERAL WORK AREA PLS PLASTER UFD UNDER FLOOR DUCT
CO CASED OPENING GR GRADE PLW PLYWOOD UG UNDERGROUND
VICINITY MAP COL COLUMN GYB GYPSUM BOARD PNL PANEL UH UNIT HEATER
COMB COMBINATION/ -ED GYPSHTG GYPSUM SHEATHING PR PAIR UNFIN UNFINISHED
CONIC CONCRETE PRELIM PRELIMINARY LINO UNLESS NOTED OTHERWISE
CONF CONFERENCE H HEIGHT/HIGH PRESS PRESSURE US UTILITY SHELF
CONN CONNECT/ -ED/ -ION HB HOSE BIB PRIM PRIMARY UTIL UTILITY
CONST CONSTRUCTION HD HAND DRYER PROJ PROJECTION
CONT CONTINUE/OUS HDCP HANDICAP PT PAINT VC VALVE CABINET
NEWPORT CONTR CONTRACT/OR HDR HEADER PVC POLYVINYL CHLORIDE VENT VENTILATION
CHANNEL CONTRTP COUNTERTOP HDW HARDWARE VERT VERTICAL
COORD COORDINATE HM HOLLOW METAL OT QUARRY TILE VEST VESTIBULE
\ CORR CORRIDOR HORIZ HORIZONTAL VTR VENT THROUGH ROOF
IN CPT CARPET HPT HIGH POINT R RADIUS
r BgYgV 1(145 W BALBOA BLVD CT CERAMIC TILE HR HANDRAIL R RISER W WIDTH/WIDE
c E CTR CENTER HT HEIGHT RA RETURN AIR W WIDE FLANGE
r CTSK COUNTERSUNK HTR HEATER RAD RADIATION W/ WITH
N CUH CABINET UNIT HEATER HVAC HEATING, VENTILATING, RB RESILIENT BASE W/O WITHOUT
CW CURTAIN WALL AIR CONDITIONING RD ROOF DRAIN WC WATER CLOSET
^ w8q[B (0 / CW COLD WATER HW HOT WATER RE RELOCATE EXISTING WC WALL COVERING
BLVD $ CYL CYLINDER HWD HARDWOOD REC RECESSED WD WOOD
0141
REF REFERENCE WDW WINDOW
C9 D DEPTH OR DEEP Ic INTERCOM REFR REFRIGERATOR WG WALL GUARD
w OC DEMO DEMOLITION ID INSIDE DIAMETER REG REGISTER WH WALL HYDRANT
EgIVFRON DPR DEPRESSION IN INCH REINF REINFORCE/-ED/-ING WHCH WHEELCHAIR
N Cl)� DEPT DEPARTMENT INSUL INSULATION REM REMOVE WHTR WATER HEATER
DET DETAIL INT INTERIOR REOD REQUIRED WPR WATERPROOF
0)DF DRINKING FOUNTAIN ISO ISOLATION RET RETAINING WR WASTE RECEPTACLE
O DIA DIAMETER REV REVERSE WS WEATHERSTRIP
DIAG DIAGONAL JAN JANITOR REV REVISE WSCT WAINSCOT
NEWPORT
DIFF DIFFUSER JB JUNCTION BOX RF RESILIENT FLOOR WT WINDOW TREATMENT
BEACH DIM DIMENSION JST JOIST RH ROOF HATCH WT WEIGHT
DISP DISPENSER JT JOINT RM ROOM WW WOOD WINDOW
DIST DISTRIBUTION RO ROUGH OPENING WWF WELDED WIRE FABRIC
DIV DIVISION KO KNOCK OUT RS ROUGH SLAB
DN DOWN
D.O. DOOR OPENING
PROJECT DATA
APN:
LOT / BLOCK:
OCCUPANCY GROUP:
TYPE OF CONSTRUCTION:
ZONING:
LOT SIZE:
Title
LOT AREA:
Site Plan
BUILDABLE AREA:
Demo Plan
EXISTING BUILDING AREA:
First Floor Plan
PROPOSED BUILDING AREA:
Second Floor Plan
GARAGE
643 SF
1 ST FLOOR
1062SF
2ND FLOOR
2063 SF
3RD FLOOR
342 SF
EXISTING FOOTPRINT:
342 SF
PROPOSED FOOTPRINT:
643 SF
PROPOSED LOT COVERAGE:
Preliminary Grading & Drainage
STORIES:
Plan
DWELLING UNITS:
Preliminary Erosion Control Plan
PARKING SPACES:
Topographic and Boundary Survey
GARAGE
2
OPEN
2
LANDSCAPING:
PLANTERS
58 SF
SOFTSCAPE
119 SF
047 252 03
LOT 12, BLOCK 10
R-3
VB
R -2,2 -UNIT RESIDENTIAL
30.75'X 102.5'
3152 SF
2289.39 SF
2235 SF
4110 SF
2028 SF
1724 SF
69%
3
2
4
177 SF
OPEN VOLUME CALC.
OPEN VOLUME AREA REQUIREMENT: 343.41 SF
15% OF BUILDABLE AREA
PROPOSED TOTAL OPEN AREA: 485 SF
INCLUDES OUTDOOR AREAS WITH A MINMUM
OF 5' DEPTH AND UNDER 24' ABOVE GRADE
PER 20.48.180 4
_:'*:
SCOPE OF WORK
20' 485 SF
THIS PROJECT INCLUDES THE DEMOLITION OF EXISTING 4 -UNIT
BUILDING, AND NEW CONSTRUCTION OF A 4110 SF DUPLEX.
UNIT 1 WILL BE 1843 SF INCLUDING 3 BEDROOMS AND 2.5
BATHROOMS. UNIT 2 WILL BE 1624 SF INCLUDING 3 BEDROOM
AND 2 BATHROOMS. EACH UNIT WILL HAVE A PRIVATE ROOF
DECK AND A SHARED GARAGE FOR PARKING 2 CARS.
LANDSCAPE PLANTERS WILL BE ADDED ALONG BALBOA BLVD.
ENTRY WALKWAYS WILL BE MADE OF CONCRETE PAVERS, SET
INTO A PERMABLE GRASS SURFACE.
FLOOR AREA LIMIT
BUILDABLE AREA:
Title
FLOOR AREA LIMITATION:
Site Plan
2 X BUILDABLE AREA
Demo Plan
THIRD FLOOR LIMITATION:
First Floor Plan
15% OF BUILDABLE AREA
Second Floor Plan
PROPOSED LIVABLE FLOOR AREA:
Third Floor Plan
PROPOSED TOTAL FLOOR AREA:
Roof Plan
1ST FLOOR
1062 SF
2ND FLOOR
2063 SF
3RD FLOOR
342 SF
GARAGE:
643 SF
GOVERNING CODES
2016 CALIFORNIA RESIDENTIAL CODE
2016 CALIFORNIA MECHANICAL CODE
2016 CALIFORNIA PLUMBING CODE
2016 CALIFORNIA ELECTRICAL CODE
2016 CALIFORNIA ENERGY CODE
2016 CALIFORNIA GREEN BUILDING CODE
2016 CALIFORNIA FIRE CODE
2289.38 SF
4578.75 SF
343.41 SF
3467 SF
4110 SF
GENERAL NOTES
1. ALL WORK SHALL BE IN COMPLIANCE WITH ALL APPLICABLE
LOCAL BUILDING CODES AND REGULATIONS. CONTRACTOR SHALL BE
RESPONSIBLE FOR PERMITS APPLICABLE TO SPECIFIC TRADES OR
SUBCONTRACTORS
2. CONTRACTOR WILL HAVE EXAMINED THE PREMISES AND SITE SO
AS TO COMPARE THEM WITH THE DRAWINGS AND WILL HAVE
SATISFIED HIMSELF AS TO THE CONDITION OF THE EXISTING WORK
AN ADJACENT PROPERTY PRIOR TO SUBMISSION OF BID. NO
ALLOWANCES WILL SUBSEQUENTLY BE MADE ON BEHALF OF THE
CONTRACTOR BY REASON OF ANY OMISSION ON HIS PART TO
INCLUDE THE COSTS OF ALL ITEMS OF WORK, EITHER LABOR OR
MATERIALS, WHETHER THEY ARE OR ARE NOT SHOWN OR NOTED
BUT WHICH ARE IMPLIED OR REQUIRED TO ATTAIN THE COMPLETED
CONDITIONS PROPOSED IN THE DRAWINGS.
3. ALL SUBCONTRACTORS TO THE GENERAL CONTRACTOR SHALL
INSPECT THE SITE AND SHALL CONVEY ANY QUESTIONS REGARDING
DESIGN INTENT AND S COPE OF WORK TO THE ARCHITECT PRIOR TO
SUBMITTING BID AND PRIOR TO COMMENCING WORK.
4. CONTRACTOR SHALL COORDINATE THE WORK OF THE VARIOUS
TRADES AND SUBCONTRACTORS AND SHALL BE RESPONSIBLE FOR
ANY ACTS, OMISSIONS, OR ERRORS OF THE SUBCONTRACTORS AND
OF PERSONS DIRECTLY OR INDIRECTLY EMPLOYED BY THEM.
5. CONTRACTOR TO ASSUME SOLE RESPONSIBILITY FOR JOB SITE
CONDITIONS INCLUDING SAFETY OF PERSONS AND PROPERTY FOR
THE DURATION OF THE PROJECT.
6. CONTRACTOR TO NOTIFY ARCHITECT IMMEDIATELY AND PRIOR TO
ORDERING OF ALL LONG LEAD ITEMS AND OF APPROXIMATE
DELIVERY DATES
7. ALL CONSTRUCTION MATERIALS AND SUPPLIES TO BE STORED,
HANDLED AND INSTALLED ACCORDING TO MANUFACTURERS'
RECOMMENDATIONS
8. IF ERRORS OR OMISSIONS ARE FOUND IN THE DRAWINGS, THEY
SHALL BE BROUGHT TO THE ATTENTION TO THE ARCHITECT BEFORE
PROCEEDING WITH THE WORK.
9. DRAWINGS SCHEMATICALLY INDICATE NEW CONSTRUCTION. THE
CONTRACTOR SHOULD ANTICIPATE, BASED ON EXPERIENCE, A
REASONABLE NUMBER OF ADJUSTMENTS TO BE NECESSARY TO
MEET THE DESIGN OBJECTIVES AND SHOULD CONSIDER SUCH
ADJUSTMENTS AS INCLUDED IN THE SCOPE OF WORK.
10. WHEN SPECIFIC FEATURE OF CONSTRUCTION ARE NOT FULLY
SHOWN ON THE DRAWINGS OR CALLED FOR IN THE GENERAL NOTES,
THEIR CONSTRUCTION SHALL BE THE SAME CHARACTER AS SIMILAR
CONDITIONS
11. THESE NOTES TO APPLY TO ALL DRAWINGS AND GOVERN
UNLESS MORE SPECIFIC REQUIREMENTS ARE INDICATED
APPLICABLE TO PARTICULAR DIVISION OF THE WORK. SEE
SPECIFICATIONS AND GENERAL NOTES IN THE SUBSECTIONS OF
THESE DRAWINGS.
12. CONTRACTOR SHALL PROVIDE, ERECT AND MAINTAIN ALL
TEMPORARY BARRIERS AND GUARDS, AND TEMPORARY SHORING
AND BRACING AS REQUIRED BY ALL CITY AND STATE REGULATIONS
13. CONTRACTOR SHALL PROVIDE ADEQUATE WEATHER
PROTECTION FOR THE BUILDING AND ITS CONTENTS DURING THE
COURSE OF WORK.
PLANNING NOTES
1. ALL OUTDOOR LIGHTING FIXTURES SHALL BE DESIGNED
SHIELDED, AIMED, LOCATED, AND MAINTAINED TO SHIELD ADJACENT
PROPERTIES AND NOT PRODUCE GLARE ONTO ADJACENT
PROPERTIES AND ROADWAYS.
2. POOLS, SPAS, WALLS, FENCES, PATIO COVERS AND OTHER
FREESTANDING STRUCTURES REQUIRE SEPARATE REVIEWS AND
PERMITS.
3. FENCES, HEDGES, WALLS, RETAINING WALLS, GUARDRAILS, AND
HANDRAILS OR ANY COMBINATION THEROF SHALL NOT EXCEED 42
INCHES FROM EXISTING GRADE PRIOR TO CONSTRUCTION WITHIN
THE REQUIRED SETBACK AREA(S).
SHEET LIST
Sheet Number Sheet Name
A-001
Title
A-101
Site Plan
A-102
Demo Plan
A-103
First Floor Plan
A-104
Second Floor Plan
A-105
Third Floor Plan
A-106
Roof Plan
A-201
Elevations
A-202
Elevations
A-301
Building Sections
A-302
Building Sections
C-1
Preliminary Grading & Drainage
Plan
C-2
Preliminary Erosion Control Plan
TP -01
Topographic and Boundary Survey
PROJECT DIRECTORY
OWNER:
Pack Investment Group, LLC
2288 North Batavia
Orange, CA 92865
(714) 685-3462 TEL
ARCHITECT:
Juintow Lin
FoxLin Architects
392 Camino de Estrella
San Clemente CA 92672
(949) 325-3001 TEL
(949) 203-3339 FAX
info@foxlin.com
CIVIL ENGINEER + SURVEYOR:
Toal Engineering, INC
139 Avenida Navarro
San Clemente, CA 92672
(949) 492-8586 TEL
(949) 498-8625 FAX
GEOTECHNICAL ENGINEER:
EGA Consultants, LLC
375-C Monte Vista Ave
Costa Mesa, CA 92627
(949) 642-9309 TEL
(949) 642-1290 FAX
STRUCTURAL ENGINEER:
TBD
MEP ENGINEER:
TBD
TITLE 24 CONSULTANT:
TBD
GENERAL NOTES
1. DO NOT SCALE DRAWINGS.
DIMENSIONS GOVERN.
2. ALL DIMENSIONS ARE TO
FACE OF STRUCTURE (F.O.S.),
UNLESS OTHERWISE NOTED.
3. ALL DIMENSIONS SHOULD
BE VERIFIED ON SITE BEFORE
PROCEEDING WITH THE WORK
4. AS -BUILT CONDITIONS TO BE
VERIFIED.
5. ANY INCONSISTENCIES OR
UNFORESEEN CONDITIONS TO
BE REVIEWED BY THE
ARCHITECT PRIOR TO
PROCEEDING WITH
CONSTRUCTION.
6. DRAWINGS REPRESENT
DESIGN INTENT ONLY -
CONTRACTOR RESPONSIBLE
FOR MEANS AND METHODS.
O/\ I architectural
design &
consulting
392 camino de estrella
san clemente, ca 92672
949 325 3001 phone
949 203 3339 fax
foxlin.com web
infoOfoxlin.com email
BALBOA DUPLEX
1045 W Balboa Blvd
Newport Beach, CA 92661
Client
Pack Investment Group, LLC
Agency Review
Title Title
Job #
10/24/17
Rev 03 - 3rd Coastal
MG
9/29/17
Rev 02 - 2nd Coastal Submittal
MG
9/06/17
Rev 01 - 1st Coastal Submittal
MG
Date
Rev # - Reason for Issue
Vb
Title Title
Job #
1718
Original Size
24 x 36
Date
10/24/2017 1:08:13 PM
Revision #
C
Drawing #
A-001
12
=DGE
.ANTER
SITE PLAN
1/4" = 1'-0"
1. ALL NOTES LABELED NOTINPERMIT(NIP) ARE NOT PART
OF THIS APPLICATION.
2. ALL NEW GRADED SLOPES SHALL BE NO STEEPER THAN
2H:1V
3. ALL SURFACE WATER MUST DRAIN AWAY FROM
BUILDING, A MINIMUM OF 5% WITHIN FIRST 10' HORIZONTAL
(2% FOR IMPERVIOUS SURFACES).
4. ALL LOOSE FOUNDATION EXCAVATION MATERIAL SHALL
BE REMOVED PRIOR TO COMMENCEMENT OF FRAMING.
SLOPES DISTURBED BY CONSTRUCTION ACTIVITIES SHALL BE
RESTORED.
5. ALL RETAINING WALLS SHALL BE PROVIDED WITH A
SUBDRAIN SYSTEM TO PREVENT POSSIBLE HYDROSTATIC
PRESSURE BEHIND THE WALL.
6. ALL ROOF AND PAD DRAINAGE SHALL BE CONDUCTED
TO THE STREET IN AN ACCEPTABLE MANNER. IF WATER
SHALL BE DISPERSED ON TO DESCENDING SLOPES,
ACQUIRE SPECIFIC APPROVAL FROM THE GRADING
SECTION AND THE CONSULTING GEOLOGIST AND/OR SOIL
ENGINEER.
Site Notes
1/4" = 1'-0"
7. ALL DECK DRAINAGE SHALL BE COLLECTED AND
CONDUCTED TO AN APPROVED LOCATION IN A NON
EROSIVE DEVICE.
8. CONTRACTOR TO REVIEW BOTH PROPOSED SITE
DRAINAGE CONDITIONS AND NOTIFY ARCHITECT OF ANY
DISCREPANCIES OR CONDITIONS THAT DO NOT ALLOW
FOR POSITIVE DRAINAGE AWAY FROM BUILDING AND
OTHER STRUCTURES. DO NOT COMMENCE SITE DRAINAGE
WORK UNTIL ALL DISCREPANCIES AND CONDITIONS HAVE
BEEN REVIEWED BY ARCHITECT.
9. ALL PIPING SHALL BE 4 -INCH DIAMETER, U.O.N. NOTIFY
ARCHITECT OF DISCREPANCIES OR UNDERSIZED PIPING
SYSTEMS.
10. ALL SOLID DRAINAGE PIPING SHALL HAVE A MINIMUM
SLOPE OF 2% UNLESS OTHERWISE NOTED.
11. 5% DRAINAGE AROUND/AWAY FROM BUILDING FOR A
MINIMUM DISTANCE OF 10'. ALTERNATIVELY, SWALES WITH
SLOPE OF 2% SHALL BE LOCATED WITHIN 10' OF BUILDING
FOUNDATION.
12. ALL EXISTING TREES TO REMAIN, UNLESS OTHERWISE
NOTED. PROTECT EXISTING TREES DURING ALL
CONSTRUCTION OPERATIONS, AS NEEDED.
13. ARCHITECT TO VERIFY ALL DRAIN LOCATIONS PRIOR TO
THEIR INSTALLATION.
14. FENCES, HEDGES, WALLS, RETAINING WALLS,
GUARDRAILS, AND HANDRAILS OR ANY COMBINATION
THEROF SHALL NOT EXCEED 42 INCHES FROM EXISTING
GRADE PRIOR TO CONSTRUCTION WITHIN THE REQUIRED
SETBACK AREA(S),
ESTABLISHED GRADE CALL.
EXISTING GRADE AT SETBACK
A 9.20' 9.20'+ 9.9'+ 10.95'+ 10.92'= 40.97'
B 9.9'
C 10.95' 40.97'/ 4 = 10.24' ESTABLISHED GRADE
D 10.92'
FFL Grade Calculation
1/8" = V-0"
D FENCE
SATE
SOD
TRY WALL
OTTED
LANTS
Z
SITE LEGEND
PROPERTY LINE
METAL FENCE
SETBACK
MG
9/29/17
WOOD FENCE
BUILDING FOOTPRINT
9/06/17
Rev 01 - 1st Coastal Submittal
LOCATION OF
FENCE
UTILITY STUB -OUTS
A
AND CLEAN -OUTS
_x_
EXISTING TREE
EXISTING UTILITIES
+HB —x—x
PROPOSED
HOSE BIB
UTILITIES
Site Legenc
1/8" = V-0"
GENERAL NOTES
1. DO NOT SCALE DRAWINGS.
DIMENSIONS GOVERN.
2. ALL DIMENSIONS ARE TO
FACE OF STRUCTURE (F.O.S.),
UNLESS OTHERWISE NOTED.
3. ALL DIMENSIONS SHOULD
BE VERIFIED ON SITE BEFORE
PROCEEDING WITH THE WORK.
4. AS -BUILT CONDITIONS TO BE
VERIFIED.
5. ANY INCONSISTENCIES OR
UNFORESEEN CONDITIONS TO
BE REVIEWED BY THE
ARCHITECT PRIOR TO
PROCEEDING WITH
CONSTRUCTION.
6. DRAWINGS REPRESENT
DESIGN INTENT ONLY -
CONTRACTOR RESPONSIBLE
FOR MEANS AND METHODS.
architectural
ox indesigns
consulting
392 camino de estrella
san clemente, ca 92672
949 325 3001 phone
949 203 3339 fax
foxlin.com web
infoOfoxlin.com email
BALBOA DUPLEX
1045 W Balboa Blvd
Newport Beach, CA 92661
Client
Pack Investment Group, LLC
Agency Review
Title Site Plan
Job #
10/24/17
Rev 03 - 3rd Coastal
MG
9/29/17
Rev 02 - 2nd Coastal Submittal
MG
9/06/17
Rev 01 - 1st Coastal Submittal
10/24/2017 1:08:14 PM
Date
Rev # - Reason for Issue
A
Title Site Plan
Job #
1718
Original Size
24 x 36
Date
10/24/2017 1:08:14 PM
Revision #
C
Drawing #
A-101
30'- 8 1/2" 6'- 6" 10.1 551-011 loot
P.L.
102.5'
N
SIDE SETBACK iv
————�
I I I I I II
I I I I I II
I I
LW I I
I
EXISTING RESIDENCE EXISTING RESIDENCEQZ ;I
z �� AND FOUNDATION AND FOUNDATION �I
Q�Mo I I I II I
W TO BE DEMOLISHED TO BE DEMOLISHED
Q j 9'-8"
I I I it I
II I
� J
I I I
-- — — — — — — — —— — -------------- —
--------
0'-71/2.. oo------------ SIDE SETBACK -----------------------------
— 102.5' '
-v
P.L.
1/4" = 1'-0"
Y
J
Q
W
0
GENERAL NOTES
1. DO NOT SCALE DRAWINGS.
DIMENSIONS GOVERN.
2. ALL DIMENSIONS ARE TO
FACE OF STRUCTURE (F.O.S.),
UNLESS OTHERWISE NOTED.
3. ALL DIMENSIONS SHOULD
BE VERIFIED ON SITE BEFORE
PROCEEDING WITH THE WORK.
4. AS -BUILT CONDITIONS TO BE
VERIFIED.
5. ANY INCONSISTENCIES OR
UNFORESEEN CONDITIONS TO
BE REVIEWED BY THE
ARCHITECT PRIOR TO
PROCEEDING WITH
CONSTRUCTION.
6. DRAWINGS REPRESENT
DESIGN INTENT ONLY -
CONTRACTOR RESPONSIBLE
FOR MEANS AND METHODS.
O/\ I architectural
design &
consulting
392 camino de estrella
san Clemente, ca 92672
949 325 3001 phone
949 203 3339 fax
foxlin.com web
infogfoxlin.com email
BALBOA DUPLEX
1045 W Balboa Blvd
Newport Beach, CA 92661
Client
Pack Investment Group, LLC
Agency Review
19/06/17 IRev 01 - 1st Coastal Submittal IMG
Pate I Rev # - Reason for Issue I%1 UYJ
Title Demo Plan
Job #
1718
Original Size
24 x 36
Date
10/24/2017 1:08:14 PM
Revision #
A
Drawing #
A-102
Z
O
ry
LL
B" Z
W
U
O
Level 1 1/8
1/4" = V-0"
3/32" = 1'-0"
• ALL DOORS AND WINDOWS DIMENSIONED
TO CENTERLINE OF CLEAR OPENING. ALL
NON -DIMENSIONED WINDOWS TO BE
CENTERED IN THE CLEAR OPENING. WHERE
LOCATION OF WINDOWS AND DOORS ARE
NOT DIMENSIONED, THEY SHALL BE PLACED
3" FROM F.O. FINISH OF ADJACENT WALL AS
INDICATED ON DRAWINGS.
• ALL CASEWORK DIMENSIONS TO FACE OF
FINISH.
• ALL INSULATION MATERIALS SHALL BE
CERTIFIED BY THE MANUFACTURER AS
COMPLYING WITH THE CALIFORNIA QUALITY
STANDARDS FOR INSULATION MATERIAL.
DOORS AND WINDOWS BETWEEN
CONDITIONED AND UNCONDITIONED SPACE
SHALL BE FULL WEATHER-STRIPPED.
• ALL DECK SURFACES SHALL BE SLOPED A
MINIMUM OF 1/4" PER FOOT, U.O.N.
• EXTERIOR DOORS ONLY TO OPEN
OUTWARDS IF EXTERIOR DOOR LANDING IS
NOT MORE THAN 0.5" LOWER THAN THE
DOOR THRESHOLD.
Plan Notes
1/4" = 1'-0"
UNIT 02
80 SF
Vk�?�7YXKS?
UNIT 01
_ 982 SF
• MANUFACTURED DOORS AND WINDOWS
SHALL BE CERTIFIED AND LABELED
INDICATED COMPLIANCE WITH THE
APPROPRIATE INFILTRATION STANDARDS.
CAULK PLUMBING AND ELECTRICAL
PENETRATIONS, ALL WINDOW AND DOOR
FRAMES, BETWEEN WALL SOLEPLATES AND
FLOORS, AND ALL OTHER OPENINGS IN THE
ENVELOPE.
• ALL EXTERIOR OPENINGS (AND OPENINGS
BETWEEN HEATED AND UNHEATED AREAS)
SHALL BE PROPERLY WEATHER-STRIPPED,
CERTIFIED AND LABELED.PROVIDE VINYL
BEAD TYPE WEATHER STRIPPING AT THESE
DOORS AND WINDOWS, ALL SIDES OF THE
DOOR MUST BE WEATHERSTRIPPED,
INCLUDING THE THRESHOLD.
• CAULK AND SEAL OPENING IN BUILDING
EXTERIOR 1/8" OR GREATER TO PREVENT
AIR INFILTRATION.
• WHERE REQUIRED, PROVIDE MINIMUM
INSULATION OF R-13 AT EXTERIOR WALLS,
AND R-30 IN ROOF AND CEILING AREAS.
BUILDING AREA
UNIT 01: 1,843 SF
UNIT 02: 11624 SF
GARAGE: 643 SF
TOTAL: 4,110 SF
• PROVIDE WOOD BLOCKING AS
REQUIRED AT ALL WALL BASE
INSTALLATIONS. REFER TO DETAIL
SHEETS FOR WALL BASE DETAILS.
• PROVIDE ADDITIONAL PLYWOOD
SHEATHING ON ALL WALLS TO RECEIVE
PLYWOOD SHEAR -WALL SHEATHING TO
COMPLETELY FLUSH OUT SUBSTRATE
SURFACE(S). ADDITIONAL SHEATHING
SHALL EXACTLY MATCH THE THICKNESS
OF THE SHEAR -WALL SHEATHING
REQUIRED. ADDITIONAL SHEATHING
SHALL CONTINUE ALONG WALL UNTIL
JUNCTION WITH A PERPENDICULAR
WALL OR END OF WALL, OR AS
DIRECTED BY DESIGNER.
• SLOPE FRAMING OR PROVIDE
DECKING/SUBSTRATE AS REQUIRED TO
PROVIDE SLOPES AS INDICATED AND
POSITIVE DRAINAGE TOWARDS DRAINS.
• STUCCO OVER WOOD SHEATHING
SHALL INCLUDE TWO LAYERS OF GRADE
"D" BUILDING PAPER.
• ALL WALL FRAMING SHALL BE
2X4 @ 16" O.C., MINIMUM, U.O.N.
• ALL GYPSUM BOARD SHALL BE
5/8" THICK, TYPE "X", U.O.N.
• ALL GYPSUM AND/OR PLASTER
SURFACES SHALL BE SMOOTH,
CONTINUOUS, FREE OF
IMPERFECTIONS, AND WITH NO
VISIBLE JOINTS, U.O.N.
• SOUND PROOF ALL AREAS OF
NEW CONSTRUCTION,
INCLUDING ALL WALLS AND
FLOORS AFFECTED BY
RENOVATION.
• PROVIDE COMBUSTION AIR
FOR WATER HEATER W/I 12"
FOR BOTTOM OF THE
COMPARTMENT
• ABS LINES TO BE PROVIDED
FROM SINKS, SHOWERS,
LAUNDRY, AND TUBS TO
GREYWATWER TANK, NO
KITCHENS AND BARS TO DRAIN
TO GREYWATER
LEGEND
D EXISTING WALL
2X4 WALL
2X6 WALL
OVERHEAD
D.S.
DOWNSPOUT
Plan Legend
1/4" = 1'-0•'
7B
Z
ALL INDOOR WATER FIXTURES MUST INCORPORATE THE FIXTURE FLOW
RATES OF SECTION 4.303 - SEE A0.2 FOR CAL GREEN NOTES
WATER EFFECTIVE FLUSH VOLUME SHALL NOT
CLOSET: EXCEED 1.28 GALLONS PER FLUSH.
SHOWERHEAD SHALL HAVE A MAXIMUM FLOW RATE OF NOT
MORE THAN 2.0 GALLONS PER MINUTE AT 80
PSI AND ASHALL BE CERTIFIED TO THE
PERFORMANCE OF THE U.S. EPA WATERSENSE
SPECIFICATION FOR SHOWERHEADS.
SHALL HAVE A MAXIMUM FLOW RATE OF 1.5
LAVATORY GALLONS PER MINUTE AT 60PSI AND A
FAUCET: MINIMUM FLOW RATE OF 0.8 GALLONS PER
MINUTE AT 20 PSI.
KITCHEN SHALL HAVE A MAXIMUM FLOW RATE OF 2.2
FAUCET: GALLONS PER MINUTE AT 60 PSI
Plumbing Fixture Table
1/4" = V-0"
CJ
VD)
GENERAL NOTES
1. DO NOT SCALE DRAWINGS.
DIMENSIONS GOVERN.
2. ALL DIMENSIONS ARE TO
FACE OF STRUCTURE (F.O.S.),
UNLESS OTHERWISE NOTED.
3. ALL DIMENSIONS SHOULD
BE VERIFIED ON SITE BEFORE
PROCEEDING WITH THE WORK.
4. AS -BUILT CONDITIONS TO BE
VERIFIED.
5. ANY INCONSISTENCIES OR
UNFORESEEN CONDITIONS TO
BE REVIEWED BY THE
ARCHITECT PRIOR TO
PROCEEDING WITH
CONSTRUCTION.
6. DRAWINGS REPRESENT
DESIGN INTENT ONLY -
CONTRACTOR RESPONSIBLE
FOR MEANS AND METHODS.
O/\ I architectural
design &
consulting
392 camino de estrella
san clemente, ca 92672
949 325 3001 phone
949 203 3339 fax
foxlin,com web
info@foxlin,com email
BALBOA DUPLEX
1045 W Balboa Blvd
Newport Beach, CA 92661
Client
Pack Investment Group, LLC
Agency Review
Title First Floor Plan
Job =_
10/24/17
Rev 03 - 3rd Coastal
MG
9/29/17
Rev 02 - 2nd Coastal Submittal
MG
9/06/17
Rev 01 - 1st Coastal Submittal
MG
Date
Rev # - Reason for Issue
V by
Title First Floor Plan
Job =_
1718
Original Size
24 x 36
Date
10/24/2017 1:08:15 PM
Revision #
C
Drawing #
A-103
N
L0
CV
N
CAS
1/4" �1'-0"
Level 2 Area plan
�� 1 3/32" = V-0"
• ALL DOORS AND WINDOWS DIMENSIONED
TO CENTERLINE OF CLEAR OPENING. ALL
NON -DIMENSIONED WINDOWS TO BE
CENTERED IN THE CLEAR OPENING. WHERE
LOCATION OF WINDOWS AND DOORS ARE
NOT DIMENSIONED, THEY SHALL BE PLACED
3" FROM F.O. FINISH OF ADJACENT WALL AS
INDICATED ON DRAWINGS.
• ALL CASEWORK DIMENSIONS TO FACE OF
FINISH.
• ALL INSULATION MATERIALS SHALL BE
CERTIFIED BY THE MANUFACTURER AS
COMPLYING WITH THE CALIFORNIA QUALITY
STANDARDS FOR INSULATION MATERIAL.
DOORS AND WINDOWS BETWEEN
CONDITIONED AND UNCONDITIONED SPACE
SHALL BE FULL WEATHER-STRIPPED.
• ALL DECK SURFACES SHALL BE SLOPED A
MINIMUM OF 1/4" PER FOOT, U.O.N.
• EXTERIOR DOORS ONLY TO OPEN
OUTWARDS IF EXTERIOR DOOR LANDING IS
NOT MORE THAN 0.5" LOWER THAN THE
DOOR THRESHOLD.
Clan Notes
/4" = 1'-0"
• MANUFACTURED DOORS AND WINDOWS
SHALL BE CERTIFIED AND LABELED
INDICATED COMPLIANCE WITH THE
APPROPRIATE INFILTRATION STANDARDS.
CAULK PLUMBING AND ELECTRICAL
PENETRATIONS, ALL WINDOW AND DOOR
FRAMES, BETWEEN WALL SOLEPLATES AND
FLOORS, AND ALL OTHER OPENINGS IN THE
ENVELOPE.
• ALL EXTERIOR OPENINGS (AND OPENINGS
BETWEEN HEATED AND UNHEATED AREAS)
SHALL BE PROPERLY WEATHER-STRIPPED,
CERTIFIED AND LABELED.PROVIDE VINYL
BEAD TYPE WEATHER STRIPPING AT THESE
DOORS AND WINDOWS, ALL SIDES OF THE
DOOR MUST BE WEATHERSTRIPPED,
INCLUDING THE THRESHOLD.
• CAULK AND SEAL OPENING IN BUILDING
EXTERIOR 1/8" OR GREATER TO PREVENT
AIR INFILTRATION.
• WHERE REQUIRED, PROVIDE MINIMUM
INSULATION OF R-13 AT EXTERIOR WALLS,
AND R-30 IN ROOF AND CEILING AREAS.
• PROVIDE WOOD BLOCKING AS
REQUIRED AT ALL WALL BASE
INSTALLATIONS. REFER TO DETAIL
SHEETS FOR WALL BASE DETAILS.
• PROVIDE ADDITIONAL PLYWOOD
SHEATHING ON ALL WALLS TO RECEIVE
PLYWOOD SHEAR -WALL SHEATHING TO
COMPLETELY FLUSH OUT SUBSTRATE
SURFACE(S). ADDITIONAL SHEATHING
SHALL EXACTLY MATCH THE THICKNESS
OF THE SHEAR -WALL SHEATHING
REQUIRED. ADDITIONAL SHEATHING
SHALL CONTINUE ALONG WALL UNTIL
JUNCTION WITH A PERPENDICULAR
WALL OR END OF WALL, OR AS
DIRECTED BY DESIGNER.
• SLOPE FRAMING OR PROVIDE
DECKING/SUBSTRATE AS REQUIRED TO
PROVIDE SLOPES AS INDICATED AND
POSITIVE DRAINAGE TOWARDS DRAINS.
• STUCCO OVER WOOD SHEATHING
SHALL INCLUDE TWO LAYERS OF GRADE
"D" BUILDING PAPER.
• ALL WALL FRAMING SHALL BE
2X4 @ 16" O.C., MINIMUM, U.O.N.
• ALL GYPSUM BOARD SHALL BE
5/8" THICK, TYPE "X", U.O.N.
• ALL GYPSUM AND/OR PLASTER
SURFACES SHALL BE SMOOTH,
CONTINUOUS, FREE OF
IMPERFECTIONS, AND WITH NO
VISIBLE JOINTS, U.O.N.
• SOUND PROOF ALL AREAS OF
NEW CONSTRUCTION,
INCLUDING ALL WALLS AND
FLOORS AFFECTED BY
RENOVATION.
• PROVIDE COMBUSTION AIR
FOR WATER HEATER W/I 12"
FOR BOTTOM OF THE
COMPARTMENT
• ABS LINES TO BE PROVIDED
FROM SINKS, SHOWERS,
LAUNDRY, AND TUBS TO
GREYWATWER TANK, NO
KITCHENS AND BARS TO DRAIN
TO GREYWATER
LEGEND
O EXISTING WALL
2X4 WALL
2X6 WALL
OVERHEAD
D.S.
DOWNSPOUT
Plan Legend
1/4" = 1'-0"
W
7B
ALL INDOOR WATER FIXTURES MUST INCORPORATE THE FIXTURE FLOW
RATES OF SECTION 4.303 - SEE A0.2 FOR CAL GREEN NOTES
WATER EFFECTIVE FLUSH VOLUME SHALL NOT
CLOSET: EXCEED 1.28 GALLONS PER FLUSH.
SHOWERHEAD SHALL HAVE A MAXIMUM FLOW RATE OF NOT
MORE THAN 2.0 GALLONS PER MINUTE AT 80
PSI AND ASHALL BE CERTIFIED TO THE
PERFORMANCE OF THE U.S. EPA WATERSENSE
SPECIFICATION FOR SHOWERHEADS.
SHALL HAVE A MAXIMUM FLOW RATE OF 1.5
LAVATORY GALLONS PER MINUTE AT 60PSI AND A
FAUCET: MINIMUM FLOW RATE OF 0.8 GALLONS PER
MINUTE AT 20 PSI.
KITCHEN
FAUCET:
Plumbing Fixture Table
1/4" = 1'-0"
SHALL HAVE A MAXIMUM FLOW RATE OF 2.2
GALLONS PER MINUTE AT 60 PSI
GENERAL NOTES
1. DO NOT SCALE DRAWINGS.
DIMENSIONS GOVERN.
2. ALL DIMENSIONS ARE TO
FACE OF STRUCTURE (F.O.S.),
UNLESS OTHERWISE NOTED.
3. ALL DIMENSIONS SHOULD
BE VERIFIED ON SITE BEFORE
PROCEEDING WITH THE WORK.
4. AS -BUILT CONDITIONS TO BE
VERIFIED.
5. ANY INCONSISTENCIES OR
UNFORESEEN CONDITIONS TO
BE REVIEWED BY THE
ARCHITECT PRIOR TO
PROCEEDING WITH
CONSTRUCTION.
6. DRAWINGS REPRESENT
DESIGN INTENT ONLY -
CONTRACTOR RESPONSIBLE
FOR MEANS AND METHODS.
0/\ I architectural
design &
consulting
392 camino de estrella
san Clemente, ca 92672
949 325 3001 phone
949 203 3339 fax
foxlin,com web
info@foxlin.com email
BALBOA DUPLEX
1045 W Balboa Blvd
Newport Beach, CA 92661
Client
Pack Investment Group, LLC
Agency Review
Title Second Floor Plan
Job #
9/29/17
Rev 02 - 2nd Coastal Submittal
MG
9/06/17
Rev 01 - 1st Coastal Submittal
MG
Date
Rev # - Reason for Issue
�jb
Title Second Floor Plan
Job #
1718
Original Size
24 x 36
Date
10/24/2017 1:08:17 PM
Revision #
B
Drawing #
A-104
B)
TRELLIS
OVERHE/
(-1� Level
- ; 1/4" = 1'-0"
2� Level 3 Area Plan
3/32" = V-0"
• ALL DOORS AND WINDOWS DIMENSIONED
TO CENTERLINE OF CLEAR OPENING. ALL
NON -DIMENSIONED WINDOWS TO BE
CENTERED IN THE CLEAR OPENING. WHERE
LOCATION OF WINDOWS AND DOORS ARE
NOT DIMENSIONED, THEY SHALL BE PLACED
3" FROM F.O. FINISH OF ADJACENT WALL AS
INDICATED ON DRAWINGS.
• ALL CASEWORK DIMENSIONS TO FACE OF
FINISH.
• ALL INSULATION MATERIALS SHALL BE
CERTIFIED BY THE MANUFACTURER AS
COMPLYING WITH THE CALIFORNIA QUALITY
STANDARDS FOR INSULATION MATERIAL.
DOORS AND WINDOWS BETWEEN
CONDITIONED AND UNCONDITIONED SPACE
SHALL BE FULL WEATHER-STRIPPED.
• ALL DECK SURFACES SHALL BE SLOPED A
MINIMUM OF 1/4" PER FOOT, U.O.N.
• EXTERIOR DOORS ONLY TO OPEN
OUTWARDS IF EXTERIOR DOOR LANDING IS
NOT MORE THAN 0.5 LOWER THAN THE
DOOR THRESHOLD.
1/4" = 1'-0"
• MANUFACTURED DOORS AND WINDOWS
SHALL BE CERTIFIED AND LABELED
INDICATED COMPLIANCE WITH THE
APPROPRIATE INFILTRATION STANDARDS.
CAULK PLUMBING AND ELECTRICAL
PENETRATIONS, ALL WINDOW AND DOOR
FRAMES, BETWEEN WALL SOLEPLATES AND
FLOORS, AND ALL OTHER OPENINGS IN THE
ENVELOPE.
• ALL EXTERIOR OPENINGS (AND OPENINGS
BETWEEN HEATED AND UNHEATED AREAS)
SHALL BE PROPERLY WEATHER-STRIPPED,
CERTIFIED AND LABELED.PROVIDE VINYL
BEAD TYPE WEATHER STRIPPING AT THESE
DOORS AND WINDOWS, ALL SIDES OF THE
DOOR MUST BE WEATHERSTRIPPED,
INCLUDING THE THRESHOLD.
• CAULK AND SEAL OPENING IN BUILDING
EXTERIOR 1/8" OR GREATER TO PREVENT
AIR INFILTRATION.
• WHERE REQUIRED, PROVIDE MINIMUM
INSULATION OF R-13 AT EXTERIOR WALLS,
AND R-30 IN ROOF AND CEILING AREAS.
I
62 SF
• PROVIDE WOOD BLOCKING AS
REQUIRED AT ALL WALL BASE
INSTALLATIONS. REFER TO DETAIL
SHEETS FOR WALL BASE DETAILS.
• PROVIDE ADDITIONAL PLYWOOD
SHEATHING ON ALL WALLS TO RECEIVE
PLYWOOD SHEAR -WALL SHEATHING TO
COMPLETELY FLUSH OUT SUBSTRATE
SURFACE(S). ADDITIONAL SHEATHING
SHALL EXACTLY MATCH THE THICKNESS
OF THE SHEAR -WALL SHEATHING
REQUIRED. ADDITIONAL SHEATHING
SHALL CONTINUE ALONG WALL UNTIL
JUNCTION WITH A PERPENDICULAR
WALL OR END OF WALL, OR AS
DIRECTED BY DESIGNER.
• SLOPE FRAMING OR PROVIDE
DECKING/SUBSTRATE AS REQUIRED TO
PROVIDE SLOPES AS INDICATED AND
POSITIVE DRAINAGE TOWARDS DRAINS.
• STUCCO OVER WOOD SHEATHING
SHALL INCLUDE TWO LAYERS OF GRADE
"D" BUILDING PAPER.
• ALL WALL FRAMING SHALL BE
2X4 @ 16" O.C., MINIMUM, U.O.N.
• ALL GYPSUM BOARD SHALL BE
5/8" THICK, TYPE "X", U.O.N.
• ALL GYPSUM AND/OR PLASTER
SURFACES SHALL BE SMOOTH,
CONTINUOUS, FREE OF
IMPERFECTIONS, AND WITH NO
VISIBLE JOINTS, U.O.N.
• SOUND PROOF ALL AREAS OF
NEW CONSTRUCTION,
INCLUDING ALL WALLS AND
FLOORS AFFECTED BY
RENOVATION.
• PROVIDE COMBUSTION AIR
FOR WATER HEATER W/I 12"
FOR BOTTOM OF THE
COMPARTMENT
• ABS LINES TO BE PROVIDED
FROM SINKS, SHOWERS,
LAUNDRY, AND TUBS TO
GREYWATWER TANK, NO
KITCHENS AND BARS TO DRAIN
TO GREYWATER
LEGEND
D EXISTING WALL
2X4 WALL
2X6 WALL
OVERHEAD
D.S.
DOWNSPOUT
Plan Legend
1/4" = 1'-0"
ALL INDOOR WATER FIXTURES MUST INCORPORATE THE FIXTURE FLOW
RATES OF SECTION 4.303 - SEE A0.2 FOR CAL GREEN NOTES
WATER EFFECTIVE FLUSH VOLUME SHALL NOT
CLOSET: EXCEED 1.28 GALLONS PER FLUSH.
SHOWERHEAD SHALL HAVE A MAXIMUM FLOW RATE OF NOT
MORE THAN 2.0 GALLONS PER MINUTE AT 80
PSI AND ASHALL BE CERTIFIED TO THE
PERFORMANCE OF THE U.S. EPA WATERSENSE
SPECIFICATION FOR SHOWERHEADS.
SHALL HAVE A MAXIMUM FLOW RATE OF 1.5
LAVATORY GALLONS PER MINUTE AT 60PSI AND A
FAUCET: MINIMUM FLOW RATE OF 0.8 GALLONS PER
MINUTE AT 20 PSI.
KITCHEN SHALL HAVE A MAXIMUM FLOW RATE OF 2.2
FAUCET: GALLONS PER MINUTE AT 60 PSI
i� Plumbing Fixture Table
1/4" = 1-0"
GENERAL NOTES
1. DO NOT SCALE DRAWINGS.
DIMENSIONS GOVERN.
2. ALL DIMENSIONS ARE TO
FACE OF STRUCTURE (F.O.S.),
UNLESS OTHERWISE NOTED.
3. ALL DIMENSIONS SHOULD
BE VERIFIED ON SITE BEFORE
PROCEEDING WITH THE WORK.
4. AS -BUILT CONDITIONS TO BE
VERIFIED.
5. ANY INCONSISTENCIES OR
UNFORESEEN CONDITIONS TO
BE REVIEWED BY THE
ARCHITECT PRIOR TO
PROCEEDING WITH
CONSTRUCTION.
6. DRAWINGS REPRESENT
DESIGN INTENT ONLY -
CONTRACTOR RESPONSIBLE
FOR MEANS AND METHODS.
O/\ I architectural
design &
consulting
392 camino de estrella
san clemente, ca 92672
949 325 3001 phone
949 203 3339 fax
foxlin,com web
info@foxlin,com email
BALBOA DUPLEX
1045 W Balboa Blvd
Newport Beach, CA 92661
Client
Pack Investment Group, LLC
Agency Review
TitleThirdFloor Plan
Job #
9/29/17
Rev 02 - 2nd Coastal Submittal
MG
9/06/17
Rev 01 - 1st Coastal Submittal
MG
Date
Rev # - Reason for Issue
✓ by
TitleThirdFloor Plan
Job #
1718
Original Size
24 x 36
Date
10/24/2017 1:08:18 PM
Revision #
B
Drawing #
A-105
1 Roof Plan
1/4" = V-0"
LEGEND
O EXISTING WALL
2X4 WALL
® 2X6 WALL
OVERHEAD
D.S.
DOWNSPOUT
Plan Legend
1/4" = 1'-0"
1. ALL ROOFING MATERIALS SHALL MEET OR EXCEED
"CLASS A" REQUIREMENTS.
2. ALL ROOF SURFACES SHALL BE SLOPED A
MINIMUM OF 1/4" PER FOOT, UNLESS OTHERWISE
NOTED.
3. PROVIDE SKYLIGHT CURBS AND SUPPORT AS
REQUIRED BY MANUFACTURER, INCLUDING MINIMUM
SLOPE REQUIREMENTS.
4. SLOPE FRAMING OR PROVIDE
DECKING/SUBSTRATE AS REQUIRED TO PROVIDE
SLOPES AS INDICATED AND POSITIVE DRAINAGE
TOWARDS DRAINS.
1/4" = V-0"
iA
N
---- --- ---0
GENERAL NOTES
1. DO NOT SCALE DRAWINGS.
DIMENSIONS GOVERN.
2. ALL DIMENSIONS ARE TO
FACE OF STRUCTURE (F.O.S.),
UNLESS OTHERWISE NOTED.
3. ALL DIMENSIONS SHOULD
BE VERIFIED ON SITE BEFORE
PROCEEDING WITH THE WORK.
4. AS -BUILT CONDITIONS TO BE
VERIFIED.
5. ANY INCONSISTENCIES OR
UNFORESEEN CONDITIONS TO
BE REVIEWED BY THE
ARCHITECT PRIOR TO
PROCEEDING WITH
CONSTRUCTION.
6. DRAWINGS REPRESENT
DESIGN INTENT ONLY -
CONTRACTOR RESPONSIBLE
FOR MEANS AND METHODS.
0/\ I architectural
design &
consulting
392 camino de estrella
san Clemente, ca 92672
949 325 3001 phone
949 203 3339 fax
foxlin.com web
infogfoxlin.com email
BALBOA DUPLEX
1045 W Balboa Blvd
Newport Beach, CA 92661
Client
Pack Investment Group, LLC
Agency Review
Title Roof Plan
Job =_
9/29/17
Rev 02 - 2nd Coastal Submittal
MG
9/06/17
Rev 01 - 1st Coastal Submittal
MG
Date
Rev # - Reason for Issue
�b
Title Roof Plan
Job =_
1718
Original Size
24 x 36
Date
10/24/2017 1:08:19 PM
Revision #
B
Drawing #
A-106
I
2 West Elevation
1/4" = V-0"
I
PL
I
I
I
I
E
ly
16.24' FASL
13.74' FASL
N
CO
North Elevation
J 1/4" = 1'-0"
�•i�0i
•22:0
'rt0i.
O•
o�OF
0
/ T
13.74' FASL
10.24' FASL
PL
MAX HEIGHT
39J4' FASL = 29' - 00"
I
5'- 1 1/4"
32.24' FASL
I
I
Level
29.24' FASL = 19'- 0"
III
I
23.24' FASL
Level 2
19474' FASL = 9'- 6"
14.74' FASL
I
CO
CD
Cf)
Level 1
FASL = 0' - 0"
T
HEIGHT
HT A
=29'-0.
Level 3
=19'-0"
Level 2
=
9'- 6"
Level 1
= 0'-0"
GENERAL NOTES
1. DO NOT SCALE DRAWINGS.
DIMENSIONS GOVERN.
2. ALL DIMENSIONS ARE TO
FACE OF STRUCTURE (F.O.S.),
UNLESS OTHERWISE NOTED.
3. ALL DIMENSIONS SHOULD
BE VERIFIED ON SITE BEFORE
PROCEEDING WITH THE WORK.
4. AS -BUILT CONDITIONS TO BE
VERIFIED.
5. ANY INCONSISTENCIES OR
UNFORESEEN CONDITIONS TO
BE REVIEWED BY THE
ARCHITECT PRIOR TO
PROCEEDING WITH
CONSTRUCTION.
6. DRAWINGS REPRESENT
DESIGN INTENT ONLY -
CONTRACTOR RESPONSIBLE
FOR MEANS AND METHODS.
O/\ I architectural
design &
consulting
392 camino de estrella
san Clemente, ca 92672
949 325 3001 phone
949 203 3339 fax
foxlin.com web
infogfoxlin.com email
BALBOA DUPLEX
1045 W Balboa Blvd
Newport Beach, CA 92661
Client
Pack Investment Group, LLC
Agency Review
Title
Elevations
Job #
10/24/17
Rev 03 - 3rd Coastal
MG
9/29/17
Rev 02 - 2nd Coastal Submittal
MG
9/06/17
Rev 01 - 1st Coastal Submittal
MG
Date
Rev # - Reason for Issue
Vb
Title
Elevations
Job #
1718
Original Size
24 x 36
Date
10/24/2017 1:08:20 PM
Revision #
C
Drawing #
A-201
C
0
0
I
Q0
2. East Elevation
J1/41' = 1'-0"
South Elevation
1/41' = 1'-0"
HEIGHT
=29'-0"
Level 3
= 19'-0"
Level 2
= 9' - 6"
Level 1
= 0'-0"
MAX HEIGHT
FASL = 29' - 0"
Level 3
' FASL = 19'- 0"
Level 2
G' FASL = 9'-6"
Level 1
G' FASL = 0'-0"
GENERAL NOTES
1. DO NOT SCALE DRAWINGS.
DIMENSIONS GOVERN.
2. ALL DIMENSIONS ARE TO
FACE OF STRUCTURE (F.O.S.),
UNLESS OTHERWISE NOTED.
3. ALL DIMENSIONS SHOULD
BE VERIFIED ON SITE BEFORE
PROCEEDING WITH THE WORK.
4. AS -BUILT CONDITIONS TO BE
VERIFIED.
5. ANY INCONSISTENCIES OR
UNFORESEEN CONDITIONS TO
BE REVIEWED BY THE
ARCHITECT PRIOR TO
PROCEEDING WITH
CONSTRUCTION.
6. DRAWINGS REPRESENT
DESIGN INTENT ONLY -
CONTRACTOR RESPONSIBLE
FOR MEANS AND METHODS.
O/\ I architectural
design &
consulting
392 camino de estrella
san Clemente, ca 92672
949 325 3001 phone
949 203 3339 fax
foxlin.com web
infogfoxlin.com email
BALBOA DUPLEX
1045 W Balboa Blvd
Newport Beach, CA 92661
Client
Pack Investment Group, LLC
Agency Review
Title
Elevations
Job #
10/24/17
Rev 03 - 3rd Coastal
MG
9/29/17
Rev 02 - 2nd Coastal Submittal
MG
9/06/17
Rev 01 - 1st Coastal Submittal
MG
Date
Rev # - Reason for Issue
Vb
Title
Elevations
Job #
1718
Original Size
24 x 36
Date
10/24/2017 1:08:21 PM
Revision #
C
Drawing #
A-202
Section 2
1/4" = 1'-0"
\"J OC nB An
Section 1
1/4" = 1'-0"
MAX HEIGHT n
59.24' FASL = 29' - 0" V
_ _ Level 3
'9.24' FASL = 19' - 0"
_ _ Level 2 1
19.74' FASL = 9'- 6"
Level1 n
10.24' FASL = 0'- 0"
.10
.91
1
-I II=I II=I II=I 11A
I II II II I
Section 3
1/4" = 1'-0"
N
1
KITCHEN
2-202
ENTRY
2-101
1
MAX HEIGHT /1
39.24' FASL = 29'- 0" V
_ _ Level 3 ,
29.24' FASL = 19' - 0" ,
_ Level2 �
19.74' FASL --- 9' - 6- 6" �1
Level 1 /1
0" \_I
--III III III—III—III--III—III—III—III—III—
III=III=III=III=1 I=I II I=1 I=1 I=1 I=1 I I-
=IIIIIIIIIIIIIIIIIIIIIIIIIIIIIII
4X HEIGHT
iL=29'-0-0" v
Level 3
)L= 19'-0" �_
_ Level 2 ,�
SL= 9'-6" �,
L WITH
0% OPEN
;TION
_ER
IUM
T 2'0"
_ Level1
SL= 0'-0"
GENERAL NOTES
1. DO NOT SCALE DRAWINGS
DIMENSIONS GOVERN.
2. ALL DIMENSIONS ARE TO
FACE OF STRUCTURE (F.O.S.),
UNLESS OTHERWISE NOTED.
3. ALL DIMENSIONS SHOULD
BE VERIFIED ON SITE BEFORE
PROCEEDING WITH THE WORK
4. AS -BUILT CONDITIONS TO BE
VERIFIED.
5. ANY INCONSISTENCIES OR
UNFORESEEN CONDITIONS TO
BE REVIEWED BY THE
ARCHITECT PRIOR TO
PROCEEDING WITH
CONSTRUCTION.
6. DRAWINGS REPRESENT
DESIGN INTENT ONLY -
CONTRACTOR RESPONSIBLE
FOR MEANS AND METHODS.
architectural
I indesign s
consulting
392 camino de estrella
san clemente, ca 92672
949 325 3001 phone
949 203 3339 fax
foxlin.com web
infoOfoxlin.com email
BALBOA DUPLEX
1045 W Balboa Blvd
Newport Beach, CA 92661
Client
Pack Investment Group, LLC
Agency Review
9/29/17
1 Rev 02 - 2nd Coastal Submittal
�
9/06/17
O
IMG
O
Rev # - Reason for Issue
✓ by
Revision #
B
Drawing #
A-301
UE
E
-I II=I II=I II=I 11A
I II II II I
Section 3
1/4" = 1'-0"
N
1
KITCHEN
2-202
ENTRY
2-101
1
MAX HEIGHT /1
39.24' FASL = 29'- 0" V
_ _ Level 3 ,
29.24' FASL = 19' - 0" ,
_ Level2 �
19.74' FASL --- 9' - 6- 6" �1
Level 1 /1
0" \_I
--III III III—III—III--III—III—III—III—III—
III=III=III=III=1 I=I II I=1 I=1 I=1 I=1 I I-
=IIIIIIIIIIIIIIIIIIIIIIIIIIIIIII
4X HEIGHT
iL=29'-0-0" v
Level 3
)L= 19'-0" �_
_ Level 2 ,�
SL= 9'-6" �,
L WITH
0% OPEN
;TION
_ER
IUM
T 2'0"
_ Level1
SL= 0'-0"
GENERAL NOTES
1. DO NOT SCALE DRAWINGS
DIMENSIONS GOVERN.
2. ALL DIMENSIONS ARE TO
FACE OF STRUCTURE (F.O.S.),
UNLESS OTHERWISE NOTED.
3. ALL DIMENSIONS SHOULD
BE VERIFIED ON SITE BEFORE
PROCEEDING WITH THE WORK
4. AS -BUILT CONDITIONS TO BE
VERIFIED.
5. ANY INCONSISTENCIES OR
UNFORESEEN CONDITIONS TO
BE REVIEWED BY THE
ARCHITECT PRIOR TO
PROCEEDING WITH
CONSTRUCTION.
6. DRAWINGS REPRESENT
DESIGN INTENT ONLY -
CONTRACTOR RESPONSIBLE
FOR MEANS AND METHODS.
architectural
I indesign s
consulting
392 camino de estrella
san clemente, ca 92672
949 325 3001 phone
949 203 3339 fax
foxlin.com web
infoOfoxlin.com email
BALBOA DUPLEX
1045 W Balboa Blvd
Newport Beach, CA 92661
Client
Pack Investment Group, LLC
Agency Review
Title Building Sections
Job #
9/29/17
1 Rev 02 - 2nd Coastal Submittal
MG
9/06/17
IRev 01 - 1st Coastal Submittal
IMG
Date
Rev # - Reason for Issue
✓ by
Title Building Sections
Job #
1718
Original Size
24 x 36
Date
10/24/2017 1:08:22 PM
Revision #
B
Drawing #
A-301
GENERAL NOTES
1. DO NOT SCALE DRAWINGS
DIMENSIONS GOVERN.
2. ALL DIMENSIONS ARE TO
FACE OF STRUCTURE (F.O.S.),
UNLESS OTHERWISE NOTED.
3. ALL DIMENSIONS SHOULD
BE VERIFIED ON SITE BEFORE
PROCEEDING WITH THE WORK.
4. AS -BUILT CONDITIONS TO BE
VERIFIED.
5. ANY INCONSISTENCIES OR
UNFORESEEN CONDITIONS TO
BE REVIEWED BY THE
ARCHITECT PRIOR TO
PROCEEDING WITH
CONSTRUCTION.
6. DRAWINGS REPRESENT
DESIGN INTENT ONLY -
CONTRACTOR RESPONSIBLE
FOR MEANS AND METHODS.
O/\ I architectural
design &
consulting
392 camino de estrella
san Clemente, ca 92672
949 325 3001 phone
949 203 3339 fax
foxlin.com web
infogfoxlin.com email
BALBOA DUPLEX
1045 W Balboa Blvd
Newport Beach, CA 92661
Client
Pack Investment Group, LLC
Agency Review
7E7A
9/29/17
O
MG
O
4 3
O
1n
Rev # - Reason for Issue
Vb
Revision #
B
Drawing #
A-302
2
3 2
A-301
A-301 A-302
-
– –
–
– MAX
H29GHI I
r
39.24' FASL
o
OUTDOOR DECK
1
it
P
N
iv 2-302
1
00 .
io
–
–
– co
Level �1
29.24' FASL = 19 - 0"
v
1
o
m
F77V
1
r
io
io
CO
KITCH / / C° DINING
`° CLO BATH MASTER BED
co
co
00
1-203 X bo 2-201
ao 2-209 2-20 2-207
'
�NilLi
\
_
I
L_�
I L
9' - 62
19.7ASL
4' F
CLO
11D
ENTRY
BED 1 BATH _
N
a,
00
1-103
- 02 1
1-10T\
1-107
LO
00
oo
r
4
�
III
_—I
—� � III �—III
III III III III
—�
�
III III
� III III III
III III III
III III �� I III III
III III III III III III III
I III _ _ � III � III III � I �II III III
--
III III III III III III III III III III III III III
III III I ILII IIIIII�III�II� � �� III � III
III III III III III III III I I FIII III III III III
Level 1
10 .24' FASL = 0'- 0"
I�I�I �
III III
1
Section 5
-III
-III -III
1/4" = 1'-0"
Q
1
1
A-302
A-301
–
MAX HEIGHT
39.24' FASL = 29' - 0"
O
1
N
O
M
O
0
1
ih
LLr
Level
M
9.24' FASL = 19'- 00"
v
1
io
CO
–
DINING
KITCHEN (o
°'
2-201
2-202
o
_
_
N
_ N Level2
%19.74'
FASL = 9' - 6"
b)
G GE 2
I
I I -III � I I � I I
-7:119 IIII III
_24'FASL=LO'e10"
� I III IIIIIII
I I I I II
I II
I I�I I I -III
I IIII-III
IIIIIIIIIIIII
IIIIIIIIIIII-III-
n
`
IIIIIIIIIIIIIII
Section 8
IIIIIIII111IIIIIIIIIIIIIIIIIIIIIILIII
1/4" = 1'-0"
GENERAL NOTES
1. DO NOT SCALE DRAWINGS
DIMENSIONS GOVERN.
2. ALL DIMENSIONS ARE TO
FACE OF STRUCTURE (F.O.S.),
UNLESS OTHERWISE NOTED.
3. ALL DIMENSIONS SHOULD
BE VERIFIED ON SITE BEFORE
PROCEEDING WITH THE WORK.
4. AS -BUILT CONDITIONS TO BE
VERIFIED.
5. ANY INCONSISTENCIES OR
UNFORESEEN CONDITIONS TO
BE REVIEWED BY THE
ARCHITECT PRIOR TO
PROCEEDING WITH
CONSTRUCTION.
6. DRAWINGS REPRESENT
DESIGN INTENT ONLY -
CONTRACTOR RESPONSIBLE
FOR MEANS AND METHODS.
O/\ I architectural
design &
consulting
392 camino de estrella
san Clemente, ca 92672
949 325 3001 phone
949 203 3339 fax
foxlin.com web
infogfoxlin.com email
BALBOA DUPLEX
1045 W Balboa Blvd
Newport Beach, CA 92661
Client
Pack Investment Group, LLC
Agency Review
Title Building Sections
Job #
9/29/17
Rev 02 - 2nd Coastal Submittal
MG
9/06/17
IRev 01 - 1st Coastal Submittal
MG
Date
Rev # - Reason for Issue
Vb
Title Building Sections
Job #
1718
Original Size
24 x 36
Date
10/24/2017 1:08:23 PM
Revision #
B
Drawing #
A-302