Loading...
HomeMy WebLinkAbout05_Campana Residence Coastal Development Permit_PA2017-263 03/13/2018 CITY OF NEWPORT BEACH ZONING ADMINISTRATOR STAFF REPORT April 12, 2018 Agenda Item No. 5 SUBJECT: Campana Residence (PA2017-263) Coastal Development Permit No. CD2018-001 SITE LOCATION: 1236 West Ocean Front APPLICANT: Gregory L. McCormick, PE OWNER: Edward and Debra Campana PLANNER: Melinda Whelan, Assistant Planner 949-644-3221, mwhelan@newportbeachca.gov LAND USE AND ZONING  General Plan: RS-D (Single-Unit Residential Detached)  Zoning District : R-1 (Single-Unit Residential)  Coastal Land Use Category: Single-Unit Residential Detached – (10.0-19.9 DU/AC) (RSD-C)  Coastal Zoning District: Single-Unit Residential (R-1) PROJECT SUMMARY A request for a coastal development permit (CDP) to allow the construction of a third- story roof deck and enclosed stairwell to an existing two-story, single-family dwelling. The enclosed stairwell with a pitched roof will provide access to the roof deck. The height of the existing dwelling will be increased by approximately eight feet to the ridge of the new pitched roof over the stairwell and by approximately two feet to the guardrail of the roof deck. The elevation of the new ridge is 40.69 feet above exising grade or 29 feet maximum. The elevation of the guardrail of the roof deck is 34.94 feet above existing grade or 24 feet maximum. The proposed development complies with all applicable development standards including height, setbacks, and floor area limits. No deviations are requested. RECOMMENDATION 1) Conduct a public hearing; 2) Find this project exempt from the California Environmental Quality Act (CEQA) pursuant to Section 15303 under Class 3 (New Construction or Conversion of Small Structures), because it has no potential to have a significant effect on the environment; and 3) Adopt Draft Zoning Administrator Resolution No. _ approving Coastal Development Permit No. CD2018-001 (Attachment No. ZA 1). 1 Campana Residence CDP Zoning Administrator, April 12, 2018 Page 2 Tmplt: 03/13/18 DISCUSSION Land Use and Development Standards  The subject property is located in the R-1 Coastal Zoning District, which provides for single-unit residential development and is consistent with the City’s Coastal Land Use Plan, General Plan, and Zoning Code. A Coastal Development Permit is required and the property is not eligible for a waiver for de minimis development because the property is located in the Coastal Commission Appeal Area.  A remodel of the existing single-family dwelling was approved and is currently under construction. The remodel was determined to be exempt from the requirement of a Coastal Development Permit. The addition of the third-story roof deck and stairwell enclosure increases the height by more than 10 percent of the existing height of the dwelling and causes the requirement for a Coastal Development Permit. The stairwell enclosure increases the gross square footage of the dwelling by seven square feet.  The property currently consists of one legal lot developed with a single-family residence. The neighborhood is predominantly developed with two- and three- story, single-family residences. The design, bulk, and scale of the development is consistent with the existing neighborhood pattern of development and expected future development consistent with applicable development standards. The addition of the third-story roof deck and enclosed stairwell remains compatible with existing and allowed development in the neighborhood.  The existing single-family dwelling and detached garage structure conform to all applicable development standards, including floor area limit, setbacks, height, and off-street parking as evidenced by the project plans and illustrated in Table 1 below. The single-family dwelling and detached garage will remain in compliance with all development standards with the addition of the third-story roof deck and enclosed stairwell. Table 1 – Development Standards Development Standard Standard Proposed Setbacks (min.) Front 8 feet 10 feet (no change) Sides 3 feet 3.75 feet and 3.50 (no change) Rear 5 feet 8.33 feet (no change) Allowable Floor Area 5,388 square feet 3,214 square feet Allowable 3rd Floor Area 404 square feet 7 square feet Open Space 404 square feet >404 square feet Parking 3-car garage 3-car garage (no change) Height 24 feet flat roof 29 feet sloped roof 24 feet flat roof 29 feet sloped roof 2 Campana Residence CDP Zoning Administrator, April 12, 2018 Page 3 Tmplt: 03/13/18 Hazards  The existing development is located on private property along the public boardwalk adjacent to the West Ocean Front beach. The beach in front of the boardwalk is approximately 500 feet wide before the Mean High Water Line of the Pacific Ocean. The addition of the third-story deck and the enclosed stairwell to access the deck is not subject to coastal hazards.  The finish floor elevation of the existing dwelling is 13.38 feet North American Vertical Datum of 1988 (NAVD88), which complies with the minimum 9.00 feet (NAVD88) elevation standard.  Pursuant to NBMC Section 21.30.030(C)(3)(i)(iv), the property owner will be required to enter into an agreement with the City waiving any potential right to protection to address situations in the future in which the development is threatened with damage or destruction by coastal hazards (e.g., waves, erosion, and sea level rise). The property owner will also be required to acknowledge any hazards present at the site and unconditionally waive any claim to damage or liability against the decision authority, consistent with NBMC Section 21.30.015(D)(3)(c). Both requirements are included as conditions of approval that will need to be satisfied prior to the issuance of building permits for construction.  The property is located in an area known for the potential of seismic activity and liquefaction. All projects are required to comply with the California Building Code (CBC) and Building Division standards and policies. Geotechnical investigations specifically addressing liquefaction are required to be reviewed and approved prior to the issuance of a building permit. Permit issuance is also contingent on the inclusion of design mitigation identified in the investigations. Construction plans are reviewed for compliance with approved investigations and CBC prior to building permit issuance. Water Quality  The project design addresses water quality with a construction erosion control plan and a post construction drainage system that includes drainage and percolation features designed to retain dry weather and minor rain event runoff on-site. Any water not retained on-site is directed to the City’s storm drain system. Public Access  The project site is located on the Balboa Peninsula between the nearest public road and the sea. Implementation Plan Section 21.30A.040 (Determination of Public Access/Recreation Impacts) requires that the provision of public access bear a 3 Campana Residence CDP Zoning Administrator, April 12, 2018 Page 4 Tmplt: 03/13/18 reasonable relationship between the requirement and the project’s impact and be proportional to the impact. In this case, the project is the addition of a third-story roof deck to an existing single-family residence located on a private lot adjacent to public boardwalk and beach. Therefore, the project does not involve a change in land use, density or intensity that will result in increased demand on public access and recreation opportunities. Furthermore, the project is designed and sited so as not to block or impede existing public access opportunities.  The public beach also includes a 12-foot-wide public sidewalk providing lateral access and views of the Pacific Ocean in front of the project site. Vertical access to the boardwalk is provided from each street end for each block. In this case the street ends at 12th Street and 13th Street. The addition of the roof deck does not impact access to the public boardwalk or beach. ENVIRONMENTAL REVIEW This project is exempt from the California Environmental Quality Act (CEQA) pursuant to Section 15303 Class 3 (New Construction or Conversion of Small Structures) of the CEQA Guidelines, California Code of Regulations, Title 14, Chapter 3, because it has no potential to have a significant effect on the environment. Class 3 exempts the demolition of up to three single-family residences and additions of up to 10,000 square feet to existing structures. The proposed project consists of the addition of a third-story roof deck to one single-family residence in the Single-Unit Residential (R-1) zoning district. PUBLIC NOTICE Notice of this public hearing was published in the Daily Pilot, mailed to all owners and residential occupants of property within 300 feet of the boundaries of the site (excluding intervening rights-of-way and waterways), including the applicant, and posted on the subject property at least 10 days before the scheduled hearing, consistent with the provisions of the Municipal Code. Additionally, the item appeared on the agenda for this meeting, which was posted at City Hall and on the City website. APPEAL PERIOD: This action shall become final and effective 14 days following the date the Resolution is adopted unless within such time an appeal or call for review is filed with the Community Development Director in accordance with the provisions of Title 21 (Local Coastal Implementation Plan) of the Newport Beach Municipal Code. Final action taken by the City may be appealed to the Coastal Commission in compliance with Section 21.64.035 of the City’s certified LCP and Title 14 California Code of Regulations, Sections 13111 through 4 Campana Residence CDP Zoning Administrator, April 12, 2018 Page 5 Tmplt: 03/13/18 13120, and Section 30603 of the Coastal Act. For additional information on filing an appeal, contact the Planning Division at 949-644-3200. Prepared by: JM/msw Attachments: ZA 1 Draft Resolution ZA 2 Vicinity Map ZA 3 Project Plans 5 03/13/2018 Attachment No. ZA 1 Draft Resolution 6 02-22-2018 RESOLUTION NO. ZA2018-### A RESOLUTION OF THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH APPROVING COASTAL DEVELOPMENT PERMIT NO. CD2018-001 TO ADD A THIRD- STORY ROOF DECK AND AN ENCLOSED STAIRWELL TO AN EXISTING SINGLE-FAMILY DWELLING LOCATED AT 1236 WEST OCEAN FRONT (PA2017-263) THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH HEREBY FINDS AS FOLLOWS: SECTION 1. STATEMENT OF FACTS. 1. An application was filed by Gregory L. McCormick, PE, with respect to property located at 1236 West Ocean Front, requesting approval of a Coastal Development Permit. 2. The lot at 1236 West Ocean Front is legally described as Lot 10, Block 12, Tract 00234. 3. The applicant proposes a coastal development permit to allow the construction of a third- story roof deck and enclosed stairwell to the existing two-story, single-family dwelling. The enclosed stairwell with a pitched roof will provide access to the roof deck. The height of the existing dwelling will be increased by approximately eight feet to the ridge of the new pitched roof over the stairwell and by approximately two feet to the guardrail of the roof deck. The proposed development complies with all applicable development standards including height, setbacks, and floor area limits. No deviations are requested. A remodel of the existing single-family dwelling was approved and is currently under construction. The remodel was determined to be exempt from the requirement of a coastal development permit. The addition of the third-story roof deck and stairwell enclosure increases the height by more than 10 percent of the existing height of the dwelling and causes the requirement for a coastal development permit. The stairwell enclosure increases the gross square footage of the dwelling by seven square feet. 4. The subject property is designated RS-D (Single-Unit Residential Detached) by the General Plan Land Use Element and is located within the R-1 (Single-Unit Residential) Zoning District. 5. The subject property located within the coastal zone. The Coastal Land Use Plan category is Single Unit Residential Detached (RSD-C) and it is located within the Single-Unit Residential (R-1) Coastal Zone District. 6. A public hearing was held on April 12, 2018, in the Corona del Mar Conference Room (Bay E-1st Floor) at 100 Civic Center Drive, Newport Beach. A notice of time, place and purpose of the hearing was given in accordance with the Newport Beach Municipal Code. Evidence, both written and oral, was presented to, and considered by, the Zoning Administrator at this hearing. 7 Zoning Administrator Resolution No. #### Page 2 of 7 12-21-2017 SECTION 2. CALIFORNIA ENVIRONMENTAL QUALITY ACT DETERMINATION. 1. This project is categorically exempt pursuant to Title 14 of the California Code of Regulations Section 15303, Article 19 of Chapter 3, Guidelines for Implementation of the California Environmental Quality Act (CEQA) under Class 3, because it has no potential to have a significant effect on the environment. 2. Class 3 exempts the demolition of up to three single-family residences and additions of up to 10,000 square feet to existing structures. The proposed project consists of the addition of a third-story roof deck to one single-family residence in the Single-Unit Residential (R-1) zoning district. SECTION 3. REQUIRED FINDINGS. In accordance with Section 21.52.015 (Coastal Development Permits, Findings and Decision) of the Newport Beach Municipal Code, the following findings and facts in support of such findings are set forth: Finding: A. Conforms to all applicable sections of the certified Local Coastal Program. Facts in Support of Finding: The proposed development complies with applicable residential development standards including, but not limited to, floor area limitation, setbacks, height, and parking. a. The maximum floor area limitation is 5,388 square feet and the existing floor area is being increased by seven square feet for a portion of the enclosed stairwell to 3,214 square feet. b. The proposed development provides the minimum required setbacks, which are eight feet along the front property line abutting the public boardwalk along West Ocean Front, three feet along each side property line and five feet along the rear property line abutting the alley. c. The new guardrail is less than 24 feet from established grade 12.19 feet North American Vertical Datum of 1988 (NAVD88) and the new sloped roof which is the highest ridge is no more than 29 feet from established grade, which comply with the maximum height requirements. d. The existing single-family dwelling includes garage parking for a total of three vehicles, which is not changing. 2. The neighborhood is predominantly developed with two- and three-story, single-family residences. The proposed design, bulk, and scale of the development is consistent with the existing neighborhood pattern of development and expected future development. 8 Zoning Administrator Resolution No. #### Page 3 of 7 12-21-2017 3. The existing development is located on private property along the public boardwalk adjacent the West Ocean Front beach. The beach in front of the boardwalk is approximately 500 feet wide before the Mean High Water Line of the Pacific Ocean, which diminishes water-related hazards. The addition of the third-story deck and the enclosed stairwell to access the deck is not subject to coastal hazards since it is on the third-story above the existing two-story single-family structure. The finish floor elevation of the existing dwelling is 13.38 feet (NAVD88), which complies with the minimum 9.00 feet (NAVD88) elevation standard 4. Pursuant to NBMC Section 21.30.030(C)(3)(i)(iv), the property owner will be required to enter into an agreement with the City waiving any potential right to protection to address situations in the future in which the development is threatened with damage or destruction by coastal hazards (e.g., waves, erosion, and sea level rise). The property owner will also be required to acknowledge any hazards present at the site and unconditionally waive any claim to damage or liability against the decision authority, consistent with NBMC Section 21.30.015(D)(3)(c). Both requirements are included as conditions of approval that will need to be satisfied prior to the issuance of building permits for construction. 5. The property is located in an area known for the potential of seismic activity and liquefaction. All projects are required to comply with the California Building Code (CBC) and Building Division standards and policies. Geotechnical investigations specifically addressing liquefaction are required to be reviewed and approved prior to the issuance of building permits. Permit issuance is also contingent on the inclusion of design mitigation identified in the investigations. Construction plans are reviewed for compliance with approved investigations and CBC prior to building permit issuance. 6. The project design addresses water quality with a construction erosion control plan and a post construction drainage system that includes drainage and percolation features designed to retain dry weather and minor rain event runoff on-site. Any water not retained on-site is directed to the City’s storm drain system. 7. Landscaping is not proposed as a part of this project. 8. The property is not located near designated Public Viewpoints or Coastal View Roads and will not impact public coastal views. Finding: B. Conforms with the public access and public recreation policies of Chapter 3 of the Coastal Act if the project is located between the nearest public road and the sea or shoreline of any body of water located within the coastal zone. 9 Zoning Administrator Resolution No. #### Page 4 of 7 12-21-2017 Fact in Support of Finding: 1. The project site is located between the nearest public road and the sea or shoreline; the project will not affect the public’s ability to gain access to, use, and/or view the coast and nearby recreational facilities. 2. The project site is located on the Balboa Peninsula between the nearest public road and the sea. Implementation Plan Section 21.30A.040 (Determination of Public Access/Recreation Impacts) requires that the provision of public access bear a reasonable relationship between the requirement and the project’s impact and be proportional to the impact. In this case, the project is the addition of a third-story roof deck to an existing single- family residence located on a private lot adjacent to the public boardwalk and beach. Therefore, the project does not involve a change in land use, density or intensity that will result in increased demand on public access and recreation opportunities. Furthermore, the project is designed and sited so as not to block or impede existing public access opportunities. 3. The public beach also includes the 12-foot-wide public sidewalk providing lateral access and views of the Pacific Ocean in front of the project site. Vertical access to the boardwalk is provided from each street end for each block. In this case the street ends at 12th Street and 13th Street. The addition of the roof deck does not impact access to the public boardwalk or beach. SECTION 4. DECISION. NOW, THEREFORE, BE IT RESOLVED: 1. The Zoning Administrator of the City of Newport Beach hereby approves Coastal Development Permit No. CD2018-001, subject to the conditions set forth in Exhibit “A,” which is attached hereto and incorporated by reference. 2. This action shall become final and effective 14 days following the date this Resolution was adopted unless within such time an appeal or call for review is filed with the Community Development Director in accordance with the provisions of Title 21 Local Coastal Implementation Plan, of the Newport Beach Municipal Code. Final action taken by the City may be appealed to the Coastal Commission in compliance with Section 21.64.035 of the City’s certified LCP and Title 14 California Code of Regulations, Sections 13111 through 13120, and Section 30603 of the Coastal Act. PASSED, APPROVED, AND ADOPTED THIS 12TH DAY OF APRIL, 2018. _____________________________________ Patrick J. Alford, Zoning Administrator 10 Zoning Administrator Resolution No. #### Page 5 of 7 12-21-2017 EXHIBIT “A” CONDITIONS OF APPROVAL 1. The development shall be in substantial conformance with the approved site plan, floor plans and building elevations stamped and dated with the date of this approval (except as modified by applicable conditions of approval). 2. Prior to the issuance of a building permit, an agreement in a form approved by the City Attorney between the property owner and the City shall be executed and recorded waiving rights to the construction of future shoreline protection devices to address the threat of damage or destruction from waves, erosion, storm conditions, landslides, seismic activity, bluff retreat, sea level rise, or other natural hazards that may affect the property, or development of the property, today or in the future. The agreement shall be binding against the property owners and successors and assigns. 3. No demolition or construction materials, equipment debris, or waste, shall be placed or stored in a location that would enter sensitive habitat, receiving waters, or a storm drain or result in impacts to environmentally sensitive habitat areas, streams, the beach, wetlands or their buffers. 4. This approval does not authorize any new or existing improvements (including landscaping) on State tidelands, public beaches, or the public right-of-way. 5. This Coastal Development Permit does not authorize any development seaward of the private property. 6. The discharge of any hazardous materials into storm sewer systems or receiving waters shall be prohibited. Machinery and equipment shall be maintained and washed in confined areas specifically designed to control runoff. A designated fueling and vehicle maintenance area with appropriate berms and protection to prevent spillage shall be provided as far away from storm drain systems or receiving waters as possible. 7. Debris from demolition shall be removed from work areas each day and removed from the project site within 24 hours of the completion of the project. Stockpiles and construction materials shall be covered, enclosed on all sites, not stored in contact with the soil, and located as far away as possible from drain inlets and any waterway. 8. Trash and debris shall be disposed in proper trash and recycling receptacles at the end of each construction day. Solid waste, including excess concrete, shall be disposed in adequate disposal facilities at a legal disposal site or recycled at a recycling facility. 9. Revisions to the approved plans may require an amendment to this Coastal Development Permit or the processing of a new coastal development permit. 11 Zoning Administrator Resolution No. #### Page 6 of 7 12-21-2017 10. The project is subject to all applicable City ordinances, policies, and standards, unless specifically waived or modified by the conditions of approval. 11. The applicant shall comply with all federal, state, and local laws. Material violation of any of those laws in connection with the use may be cause for revocation of this Coastal Development Permit. 12. This Coastal Development Permit may be modified or revoked by the Zoning Administrator if determined that the proposed uses or conditions under which it is being operated or maintained is detrimental to the public health, welfare or materially injurious to property or improvements in the vicinity or if the property is operated or maintained so as to constitute a public nuisance. 13. Prior to issuance of a building permit, a copy of the Resolution, including conditions of approval Exhibit “A” shall be incorporated into the Building Division and field sets of plans. 14. Prior to issuance of a building permit, the applicant shall submit to the Planning Division an additional copy of the approved architectural plans for inclusion in the Coastal Development file. The plans shall be identical to those approved by all City departments for building permit issuance. The approved copy shall include architectural sheets only and shall be reduced in size to 11 inches by 17 inches. The plans shall accurately depict the elements approved by this Coastal Development Permit. 15. Prior to the issuance of building permits, the applicant shall submit a final landscape and irrigation plan. These plans shall incorporate drought tolerant plantings, non-invasive plant species and water efficient irrigation design. The plans shall be approved by the Planning Division. 16. All landscape materials and irrigation systems shall be maintained in accordance with the approved landscape plan. All landscaped areas shall be maintained in a healthy and growing condition and shall receive regular pruning, fertilizing, mowing, and trimming. All landscaped areas shall be kept free of weeds and debris. All irrigation systems shall be kept operable, including adjustments, replacements, repairs, and cleaning as part of regular maintenance. 17. Prior to the issuance of building permit, the applicant shall pay any unpaid administrative costs associated with the processing of this application to the Planning Division. 18. Should the property be sold or otherwise come under different ownership, any future owners or assignees shall be notified of the conditions of this approval by the current property owner or agent. 19. This Coastal Development Permit No. CD2018-001 shall expire unless exercised within 24 months from the date of approval as specified in Section 21.54.060 (Time Limits and Extensions) of the Newport Beach Municipal Code, unless an extension is otherwise granted. 12 Zoning Administrator Resolution No. #### Page 7 of 7 12-21-2017 20. To the fullest extent permitted by law, applicant shall indemnify, defend and hold harmless City, its City Council, its boards and commissions, officials, officers, employees, and agents from and against any and all claims, demands, obligations, damages, actions, causes of action, suits, losses, judgments, fines, penalties, liabilities, costs and expenses (including without limitation, attorney’s fees, disbursements and court costs) of every kind and nature whatsoever which may arise from or in any manner relate (directly or indirectly) to City’s approval of Campana Residence Roof Deck including, but not limited to, Coastal Development Permit No. CD2018-001 (PA2017-263). This indemnification shall include, but not be limited to, damages awarded against the City, if any, costs of suit, attorneys' fees, and other expenses incurred in connection with such claim, action, causes of action, suit or proceeding whether incurred by applicant, City, and/or the parties initiating or bringing such proceeding. The applicant shall indemnify the City for all of City's costs, attorneys' fees, and damages, which City incurs in enforcing the indemnification provisions set forth in this condition. The applicant shall pay to the City upon demand any amount owed to the City pursuant to the indemnification requirements prescribed in this condition. 13 03/13/2018 Attachment No. ZA 2 Vicinity Map 14 03/13/2018 VICINITY MAP Coastal Development Permit No. CD2018-001 PA2017-263 1236 West Ocean Front Subject Property 15 03/13/2018 Attachment No. ZA 3 Project Plans 16 Total Sheet Count: 24T.1 COVER SHEET : Plotted on 2/19/18 at 4:16 PM by Gregory Nutt. File Path: /Volumes/McNaughten Media/Kemmerer Design Arch/R-Campana/Campana ArchiCAD Models/Campana v4.2 for CDP.pln 2/19/18 T.1 COVER SHEET1236 WEST OCEAN FRONTNEWPORT BEACH, CA 92661CAMPANA RESIDENCECOASTAL DEVELOPMENT PERMITLICE N S E D ARCHITE C T NROFILACFOETA T S IAMARC U S KEMME R E RNO. C-29552 REN: 06/30/19 ★★ Revisions: Date: Drawn by: Seal: Date:This document, and the ideas and designs incorporated here-in, asan instrument of professional service, is the property of KemmererDesign Architecture, Inc. (KDA), and is not to be used in whole orpart, for any other project without the written authorization of KDA.This document is not to be reproduced and/or modified in any way,nor shall any reproduction of the this document be modified withoutthe prior written consent of KDA.This document has been prepared to describe proposed new workand does not necessarily represent as-built or existing conditions.The architect does not warrant, in any way, the accuracy of theinformation and shall not be responsible for any discrepancybetween this document and the existing conditions.Checked by: GSN MK Job Status:DESIGN Revisions:Date: Sheet Number: Drawing:KEMMERER DESIGN ARCHITECTURE, INC.228 CREST AVENUEHUNTINGTON BEACH, CA 92648p. 714.752.0052marcus@kdarch.com/www.kdarch.comPROJECT SCOPE REMODEL NEW ROOFTOP DECK EXISTING USE RESIDENCE 1ST FLOOR FT2 2ND FLOOR FT2 TOTAL FT2 GARAGE 665 FT2 ZONING DISTRICT R-1 (SINGLE-UNIT RESIDENTIAL) COASTAL ZONING DISTRICT SITE COVERAGE N/A (LOTS 40 FT. WIDE OR LESS) SITE AREA 3,769 FT2 BUILDABLE AREA 2,694 FT2 FLOOR AREA LIMIT 5,388 FT2 OCCUPANCY GROUP R-3 CONSTRUCTION TYPE V-B (NON-SPRINKLERED) NO. OF STORIES 2 STORY BUILDING 2016 - TITLE 24 CALIFORNIA CODE OF REGULATIONS PART 1 CALIFORNIA ADMINISTRATIVE CODE PART 2 CALIFORNIA BUILDING CODE PART 2.5 CALIFORNIA RESIDENTIAL CODE PART 3 CALIFORNIA ELECTRICAL CODE PART 4 CALIFORNIA MECHANICAL CODE PART 5 CALIFORNIA PLUMBING CODE PART 6 CALIFORNIA ENERGY CODE PART 9 CALIFORNIA FIRE CODE PART 10 CALIFORNIA EXISTING BUILDING CODE PART 11 CALIFORNIA GREEN BUILDING STANDARDS CODE PART 12 CALIFORNIA REFERENCE STANDARD CODE CITY OF NEWPORT BEACH MUNICIPAL CODE OWNER CAMPANA RESIDENCE 1236 WEST OCEAN FRONT NEWPORT BEACH, CA 92661 ARCHITECTURAL SERVICES Kemmerer Design Architecture, Inc. Marcus Kemmerer, AIA, NCARB, Leed AP 228 Crest Ave. Huntington Beach, CA 92648 t. 714.752.0052 f. 714.969.9059 marcus@kdARCH.com www.kdARCH.com STRUCTURAL ENGINEERING MECHANICAL / ELECTRICAL / PLUMBING Gregory L McCormick, PE 18015 Briar Street Fountain Valley, CA 92708 t. 951.315.1081 gmccormickpe@gmail.com ID T.1 TS CPPP A-101 A-102 A-103 A-104 A-201 A-301 Name COVER SHEET TOPOGRAPHICAL SURVEY 1ST FLOOR PLANS 2ND FLOOR PLANS ROOF DECK PLAN ELEVATIONS SECTIONS PROJECT SITE ACOUS. ACOUSTICAL MAX. MAXIMUM ADD'L ADDITIONAL MECH. MECHANICAL ADJ. ADJUSTABLE MET. METAL ALUM. ALUMINUM MFR. MANUFACTURER APPROX. APPROXIMATE MIN. MINIMUM MISC. MISCELLANEOUS BD. BOARD M.O. MASONRY OPENING BLDG. BUILDING MTD. MOUNTED BLK. BLOCK MUL. MULLION BLKG. BLOCKING BM. BEAM N.I.C. NOT IN CONTRACT BOT. BOTTOM NO. NUMBER N.T.S. NOT TO SCALE CAB. CABINET CEM. CEMENT O.A. OVERALL CER. CERAMIC OBS. OBSCURE C.I. CAST IRON O.C. ON CENTER CLR. CLEAR O.D. OUTSIDE DIAMETER COL. COLUMN CONC. CONCRETE O.F.C.I. OWNER FURNISHED CONN. CONNECTION CONT. CONTINUOUS OFF. OFFICE C.T. CERAMIC TILE OPNG. OPENING CTSK. COUNTERSUNK OPP. OPPOSITE DECOR. DECORATIVE PL. PLATE DET. DETAIL PLAS. PLASTER D.F. DOUGLAS FIR PLYWD. PLYWOOD DIA. DIAMETER PR. PAIR DIM. DIMENSION PRCST. PRECAST DN. DOWN P.T.D.F. PRESSURE-TREATED D.S. DOWNSPOUT DOUGLAS FIR DWG. DRAWING PTN. PARTITION EA. EACH Q.T. QUARRY TILE EL. ELEVATION ELEC. ELECTRICAL R. RISER EQ. EQUAL RAD. RADIUS EXH. EXHAUST REINF. REINFORCE EXP. EXPANSION REQ. REQUIRED EXT. EXTERIOR RM. ROOM EXIST. EXISTING R.O. ROUGH OPENING RWD. REDWOOD F.A.U. FORCED AIR UNIT R.W.L. RAIN WATER LEADER F.D. FLOOR DRAIN F.H.C. FIRE HISE CABINET S.C. SOLID CORE FIN. FINISH SCHED. SCHEDULE FL. FLOOR SHT. SHEET FLASH. FLASHING SIM. SIMILAR FLUOR. FLUORESCENT SQ. SQUARE F.O.C. FACE OF CONCRETE SST. STAINLESS STEEL F.O.F. FACE OF FINSIH STL. STEEL F.O.M. FACE OF MASONRY STOR. STORAGE F.O.S. FACE OF STUD STRUCT. STRUCTURAL F.S. FLOOR SINK SUSP. SUSPENDED FT. FOOT/FEET SYM. SYMMETRICAL FTG. FOOTING T. TREAD GA. GAUGE T.C. TOP OF CURB GALV. GALVANIZED TEL. TELEPHONE GL. GLASS T&G TOUNGE & GROVE GR. GRADE THK. THICK GYP. GYPSUM T.O.C. TOP OF CHIMNEY H.B. HOSE BIBB T.O.F.R. TOP OF FRAMING H.C. HOLLOW CORE T.O.L. TOP OF LEDGER HDWD. HARDWOOD T.O.M. TOPOF MASONRY HDWE. HARDWARE T.O.P TOP OF PARAPET HGT. HEIGHT T.O.PL. TOP OF PLATE H.M. HOLLOW METAL HORIZ. HORZONTAL I.D. INSIDE DIAMETER U.O.N. UNLESS OTHERWISE INCAND. INCANDESCENT NOTED INSUL. UNSULATION VERT. VERTICAL INT. INTERIOR VEST. VESTIBULE VG.D.F. VERTICAL GRAIN JAN. JANITOR DOUG;AS FIR JT. JOINT W/ WITH LAM. LAMINATED W/O WITHOUT LAV. LAVATORY W.C. WATER CLOSET LOC. LOCATION WD. WOOD WDW. WINDOW W.H. WATER CLOSET WSCT. WAINSCOT W.T. WEIGHT 1. All construction and materials shall be as specified and in accordance with all applicable codes, ordinances, laws, permits, and the contract documents. 2. The contractor shall be responsible for the accurate placement of all new construction on the site. 3. The contractor shall verify all dimensions and site conditions before starting work. Should a discrepancy appear in the contract documents, or between the contract documents and existing conditions, notify the architect at once for instruction on how to proceed. 4 should a conflict occur in or between drawings and specifications, the specifications shall take precedence, unless a written decision from the architect has been obtained which describes a clarification or alternate method and/or materials. 5. The contractor shall confine his operations on the site to areas permitted by the landlord. 6. The job site shall be maintained in a clean, orderly condition free of debris and litter, and shall not be unreasonably encumbered with any materials or equipment. Each sub-contractor immediately upon completion of each phase of his work shall remove all trash and debris as a result of his operation. 7. All material stored on the site shall be properly stacked and protected to prevent damage and deterioration. Failure to protect materials may be cause for rejection of work. 8. The contractor shall do all cutting, fitting, or patching of his work that may be required to make its several parts fit together properly and shall not endanger any other work by cutting, excavating, or otherwise altering the total work or any part of it. all patching, repairing, and replacing of materials and surfaces, cut or damaged in execution of work, shall be done with applicable materials so that surfaces replaced will, upon completion, match surrounding similar surfaces. 9. No portion of the work requiring a shop drawing or sample submission shall be commenced until the submission has been reviewed by the architect. All such portions of the work shall be in accordance with corrected shop drawings and samples. 10. Dimensions: a. All dimensions shall take precedence over scale. b. All dimensions are to the finish surface unless otherwise noted. c. Ceiling height dimensions are from finish floor slab to face of finish ceiling material unless otherwise noted. 11. Provide all necessary blocking, backing, and framing for light fixtures, electric units, a.c. equipment, recessed items, and all other items as required. 12. Where larger studs or furring are required to cover piping and conduits, the larger stud size or furring shall extend the full surface of the wall width and length where the furring occurs. 13. Provide fire sprinkler protection throughout the building. The contractor shall be responsible for preparing the drawings and obtaining the permits for the fire sprinkler system. The fire sprinkler systems shall meet the requirements of all applicable codes and ordinances. 14. Provide fire extinguishers per the requirements of local governing agencies. 15. Provide all access panels as required by governing codes to all concealed spaces, voids, attics, etc. Verify type required with architect prior to installation. 16. Fire damper assemblies, including sleeves, and installation procedures must be at the building site for the inspectors use. 17. Exit signs shall be visible from any direction of approach and shall clearly indicate the direction of egress travel 18. Capacity of room posted in a conspicuous place on an approved sign near the main exit or exit- access doorway to each room or area. 19. "lighting and mechanical fixtures must be supported by additional independant no.12 gage wires attached to each corner of fixture", (unless ceiling system has been designed to fully support the fixtures). 20. Deferred submittals to be reviewed by the project architect or engineer of record and certified prior to submittal for plan review. MEASUREMENTS 1. In general, the measurements on the Drawings are reasonable and accurate for the purpose of design intent. However, in the execution of the work on the project, the Contractor is to verify all dimensions with actual conditions on the job in order to make a perfect fit; the requirements of the Samples and Shop Drawings section notwithstanding. Where the work of one Contractor is to join that of another, both are to furnish shop drawings showing the actual dimensions and the method of joining the work of the two trades. These drawings may be in addition to any drawings requested or as listed under "Shop Drawings." 2. No extra charge or compensation will be allowed on account of differences between actual dimensions and the measurements indicated on the Drawings. Any differences which may be found shall be submitted to The Architect for consideration before proceeding with the work. SPECIFICATIONS AND DRAWINGS 1. If any errors or omissions appear in the Contract Documents, the Contractor shall notify the Architect in writing of such error or ommission. If the Contractor fails to give such notice, whether prior to or during the execution of the work, he will be held responsible for results of such errors or omissions and for cost of rectifying same. 2. The general character of the detail work is shown on the Drawings but minor modifications may be made by the Architect & Tenant with Lanlord approval. All drawings illustrate design intent. GENERAL NOTES 1. Prior to any construction, Contractor shall meet with The Architect 2. Information contained in these drawings may require adjustments or modifications to conform with existing conditions. In cases where changes in details are necessary, these drawings shall be used to show the design intent only. Contractor shall verify all dimensions concerning existing and new work and notify the Architect before proceeding with either fabrication or installation of the work. In addition, Contractor shall notify the Architect immediately, should existing conditions prohibit execution of the design intent of the drawings. Any additional work, demolition and/or removal as a result of failure to do so will be at Contractor's expense. 3. Due to the small scale of these plans and the instability of the blueprint paper, these drawings shall NOT BE SCALED and any critical dimensions should be field checked. The Contractor(s) shall be responsible to field measure existing conditions prior to beginning of work and periodically during construction progress to verify all critical dimensions. Any deviation from dimensions indicated on the drawings is to be approved by the Architect prior to construction. 4. The Contractor shall visit the site and be aware of existing conditions to the extent and influence of the work prior to bidding & construction. Contractor shall be familiar with all applicable building codes and ICC codes. No subsequent extras or additions will be allowed for any claim of lack of knowledge of conditions or circumstances about which the Contractor could have site inspected and informed himself. Appointments shall be arranged through the Architect. 5. Before commencing work, the Contractor shall notify the Architect of any areas that have not been satisfactorily completed by the Landlords base building contractor to meet the lease requirements including, but not limited to, (fire-proofing, ductwork, condition of slab, condition of core and demising walls, utility hook-up, electrical panels, etc.). 6. All Contractors shall comply with the rules and regulations of the building as to hours of operation for the purposes of delivery and also as the manner of handling materials, equipment and debris, to avoid conflict and interference with normal building operation. All Contractors shall receive specific regulations from the Architect. 7. The Contractor is responsible for verifying the extent, nature and scope of work described in the contract documents and will coordinate with the Landlord's Representative the interfacing of the Base Building Contractor's work and the work shown and described in the contract documents. The Contractor is to provide all labor and materials necessary to execute all work necessary to achieve substantial completion. He shall be responsible for coordinating his work with that of all other trades, including those operating under separate contract with the Tenant and Landlord. 8. All work shall be performed by skilled and qualified workmen and in accordance with the best practices of the trades involved. Care shall be taken to ensure compliance with building regulations and/or governmental laws, statutes or ordinances concerning the use of union labor. 9. All materials shall be new, unused and of the highest quality in every respect unless otherwise noted. Manufactured materials and equipment shall be installed as per instructions unless otherwise noted. Maintenance manufacturer's written recommendations and instructions, in triplicate, shall be provided for all materials used within the project in a 3 ring binder in CSI format with CSI numbered tabs. Three copies shall go the Owner. 10. Perform all work in accordance with rules and regulations of governmental agencies having jurisdiction and conform to all City, County, State and Federal construction, safety and sanitary laws, codes, statutes and ordinances. Report promptly any discrepancies, variations or omissions in the contract documents to the Architect. 11. Instructions on the Drawings and Schedules, notwithstanding construction, shall comply in all respects with applicable Federal, State, County and/or local statutes, ordinances, regulations, laws and codes. 12. Supply, prior to commencing work, a list of all Subcontractors to the Owner's Representative for review and acceptance. Include the name of the principal contact, the address and phone number of each Subcontractor in this list. 13. All Contractors shall be responsible for the distribution of drawings to all trades. 14. Contractor is to provide a dumpster for use during construction and for use during the store fixtures installation. The project is to be kept clear of debris at all times. 15. Any discrepancies found in the plans, dimensions, existing conditions or specifying of a product or its use are to be pointed out to the Architect Addenda will be issued as necessary for these discrepancies and other reasons and will become part of the contract documents. For those discrepancies not brought to the attention of the Architect, it will be assumed that the Contractor has bid the more expensive material and/or method of construction. 16. All installed plumbing, mechanical and electrical equipment shall operate quietly and free of vibration. 17. Do not substitute materials where a manufacturer is specified unless submitted to the Tenant & Landlord for approval. Where the term "or approved equal" is used, the Architect shall determine equality, based on information submitted by the Contractor for approval. Unless said approval is received by contractor, it will be assumed that the contractor's total bid is based upon specified materials and equipment. 18. Perform all work in a good and workmanlike manner and prosecute to completion with all due diligence. Time is of the essence with respect to the work performed under this contract. 19. Perform all cutting and patching in a neat, workman like manner. Repair to match existing, in kind and finish, any existing finishes that are to remain and are disturbed or damaged by the Contractor during the course of the work. 20. Coordinate all wall, floor and ceiling finishes to ensure that joints and transitions between materials, whether they be wall to wall, wall to floor, floor to floor, wall to ceiling, or ceiling to ceiling, will be smooth, true, level and in accordance with the drawings, specifications and schedules. 21. Store all work and material to accomplish designated work within the demised space unless otherwise indicated. 22. Thoroughly clean all interior surfaces, including glass, floor surfaces, and millwork, prior to occupancy of the space by Tenant. Remove all trash, construction debris, tools, etc. prior to occupancy. 23. Place all studs, ceiling furring and framing members so as to avoid interference with locations of recessed lighting fixtures, piping, ductwork and the like. 24. Work shall be subject to the inspection of the Tenant & Landlord. Any work not found in compliance with good construction standards shall be corrected without additional cost to the Tenant or Landlord. 25. Upon completion of the work, all facilities shall be in full use, without defects. 26. Upon completion of the work, warranties shall be assigned by the Contractor to the Owner's Representative. Any Contractor or Subcontractor performing the work shall be responsible for the replacement or repair, without additional charge to the Owner, of any and all work done or furnished by or through such Contractor or Subcontractor which shall become defective within one year after Substantial Completion of the work. The corrections of such work shall include, without additional charge to the Owner, all additional expenses and damages in connection with such removal, replacement of, or any part of the work or part of the building which may be damaged or disturbed thereby.This warranty shall in no way void any manufacturer's warranties on materials or equipment for which the normal warranty period exceeds one year, without defects. 27. All light fixtures, diffusers, electrical outlets and the like shall be covered prior to any sanding to prevent fine dust from entering the systems. 28. No approval by the Architect is valid unless in writing, and signed by the tenant's Repesentative. 29. Coordinate work with that of all other Owner contracted work. Cooperate with, integrate and schedule this work into the overall sequence of the project, to ensure that all work is completed within the approved Contract. 30. It is expected that sufficient labor will be provided so that activity for any given trade will not be limited to only one part of the total work area. 31. Each trade shall proceed in a fashion that will not delay or detain the trades following them. 32. Provide and complete all preliminary work and temporary construction as may be reasonably required by the scope of work or as indicated elsewhere in the contract documents. 33. Contractor to provide temporary light and power service on-site as needed, if not existing. Review plans and verify with Architect on availability. 34. Provide heat as necessary to protect the work against damage from dampness and cold. System shall be sufficient to maintain a minimum temperature of 50 degrees. System may be existing. Verify availability with Architect. 35. Provide barricades where necessary to protect the public, to provide security to the store and to confine all dust and odor to the construction area. This must be constructed as required by the Landlord. 36. These drawings are for Design Intent and alternate details will be considered. Submit drawings with proposed alterations for review and approval by the Architect. 37. Each subcontractor is considered a fully qualified specialist in his respective field and shall, prior to submission of bid Notify the Contractor of any work called out in his trade that cannot be executed or fully guaranteed. 38. Contractor to provide fire-treated blocking in walls and ceiling as required for attachment of fixtures throughout. Coordinate with work by others. 39. By the covering up of a previous sub-contractor's work it is assumed that the Contractor has inspected the previous work and has rendered it acceptable. 40. All required roof openings are to be made by the Landlord approved roofing contractor and shall include all cutting, reinforcing, cures, flashing, and new roofing at Tenant expense. 41. It is the responsibility of the Contractor to become familiar with all landlord requirements, criteria, and restrictions. All work performed as a part of this project must be carefully coordinated with the Landlord and be in full compliance with all Landlord restrictions. 42. Bathroom exhaust fans shall be ducted to the roof. Contractor shall submit weatherproof roof penetration and duct termination details to the Architect for review prior to roof installation. PROJECT INFORMATIONPROJECT LOCATION & CONTACTS SHEET INDEX VICINITY MAP ABBREVIATION LIST BUILDING DEPARTMENT NOTES GENERAL NOTES 3 IfL.C nr rrit ■ --::C Tlti ■■ *- r Irr y.!J t £JZ*T 21finfp™ rr,=^r re /'i \ A /.■4% HTT ] [Vqhioolaib^a °aB/ft <vaftbc,°3B/\*0<*>El ft X'&z0®OgCO ft *Lux Photobooth ftjr- 03 ^0 BSanfro Ofe,'Tqo? ‘"^etv Wh,,9 ft**ftsrt Tfe Oberman Denysot>a EROSION CONTROL PLAN ARCHITECTURAL SITE PLANARCHITECTURAL SITE PLAN PROPOSED RESIDENCE 1ST FLOOR FT2 (NO CHANGE) 2ND FLOOR FT2 (NO CHANGE) 2ND FLOOR 1,287 FT TOTAL GARAGE 665 FT2 (NO CHANGE) DOGHOUSE 7 FT (STAIRWELL)2 FT2 1,269 1,273 2,542 2,549 1,269 1,273 17 2/2/2018 TS 18 19 Total Sheet Count: 24A-101 ARCHITECTURAL SITE PLAN : Plotted on 2/19/18 at 4:16 PM by Gregory Nutt. File Path: /Volumes/McNaughten Media/Kemmerer Design Arch/R-Campana/Campana ArchiCAD Models/Campana v4.2 for CDP.pln 2/19/18 A-101 ARCHITECTURAL SITE PLAN 1236 WEST OCEAN FRONTNEWPORT BEACH, CA 92661CAMPANA RESIDENCECOASTAL DEVELOPMENT PERMITLICE N S E D ARCHITE C T NROFILACFOETA T S IAMARC U S KEMME R E RNO. C-29552 REN: 06/30/19 ★★ Revisions: Date: Drawn by: Seal: Date:This document, and the ideas and designs incorporated here-in, asan instrument of professional service, is the property of KemmererDesign Architecture, Inc. (KDA), and is not to be used in whole orpart, for any other project without the written authorization of KDA.This document is not to be reproduced and/or modified in any way,nor shall any reproduction of the this document be modified withoutthe prior written consent of KDA.This document has been prepared to describe proposed new workand does not necessarily represent as-built or existing conditions.The architect does not warrant, in any way, the accuracy of theinformation and shall not be responsible for any discrepancybetween this document and the existing conditions.KEMMERER DESIGN ARCHITECTURE, INC.228 CREST AVENUEHUNTINGTON BEACH, CA 92648p. 714.752.0052marcus@kdarch.com/www.kdarch.comChecked by: GSN MK Job Status:DESIGN Revisions:Date: Sheet Number: Drawing:PLANNORTH15.82' 3.00'3.50'3.75'8.33'27.83'10.14' (N) BALCONY (E) 36" GATE (E) CMU WALL (E) CMU WALL (E) CMU WALL ALLOWABLE 2nd FLR BALCONY ENCROACHMENT (E) GARAGE (E) 2-STORY RESIDENCE PROPERTY LINE 35.75'(E) SLOPE SEE TOPO (E) CONCRETE WALKWAY (E) CONCRETE WALKWAY (E) CONCRETE WALKWAY (E) CONCRETE WALKWAY PROPERTY LINE 102.50' PROPERTY LINE 102.50' (E) SLOPE SEE TOPO (E) SLOPE SEE TOPO (E) SLOPE SEE TOPO PROPERTY LINE 35.09'ALLEYOCEANFRONT3 A-301 3 A-301 0 4'8'12'SCALE: 3/16" = 1'-0"1SITE PLAN 20 Total Sheet Count: 24A-102 1ST FLOOR PLANS : Plotted on 2/19/18 at 4:16 PM by Gregory Nutt. File Path: /Volumes/McNaughten Media/Kemmerer Design Arch/R-Campana/Campana ArchiCAD Models/Campana v4.2 for CDP.pln 2/19/18 A-102 1ST FLOOR PLANS1236 WEST OCEAN FRONTNEWPORT BEACH, CA 92661CAMPANA RESIDENCECOASTAL DEVELOPMENT PERMITLICE N S E D ARCHITE C T NROFILACFOETA T S IAMARC U S KEMME R E RNO. C-29552 REN: 06/30/19 ★★ Revisions: Date: Drawn by: Seal: Date:This document, and the ideas and designs incorporated here-in, asan instrument of professional service, is the property of KemmererDesign Architecture, Inc. (KDA), and is not to be used in whole orpart, for any other project without the written authorization of KDA.This document is not to be reproduced and/or modified in any way,nor shall any reproduction of the this document be modified withoutthe prior written consent of KDA.This document has been prepared to describe proposed new workand does not necessarily represent as-built or existing conditions.The architect does not warrant, in any way, the accuracy of theinformation and shall not be responsible for any discrepancybetween this document and the existing conditions.KEMMERER DESIGN ARCHITECTURE, INC.228 CREST AVENUEHUNTINGTON BEACH, CA 92648p. 714.752.0052marcus@kdarch.com/www.kdarch.comChecked by: GSN MK Job Status:DESIGN Revisions:Date: Sheet Number: Drawing: B2 A-813 A5 A-813 A2 A-813 C1 A-813 C1 A-814 B1 A-814 C2 A-814 1 42"x60" FIBERGLASS OVAL TUB ON 18" HIGH MOISTURE RESISTANT PLATFORM 2 48"X66" HAND MADE SHOWER PAN W/ TILE TO 72" A.F.F. W/ SHOWER HEAD AT +80" A.F.F. MIX WATER TO SHOWERS, SHALL BE LIMITED TO 120˚F. PROVIDE WATER TEMPERING VALVE CONFORM TO ASSE 1016 FOR SHOWERS. PROVIDE WATER TEMPERING VALVE CONFORM TO ASSE 1069 FOR GANG SHOWER. 3 HIGH EFFICIENCY TOILET (MAXIMUM 1.28 GALLONS PER FLUSH) 4 RECESSED MEDICINE CABINET (REFER TO INTERIOR ELEVATIONS) 5 SHATTER RESISTANT SHOWER ENCLOSURE FULLY TEMPERED OR LAMINATED SAFETY GLASS 6 TOWEL BAR (PROVIDE BLOCKING WHEN REQUIRED) 7 TOILET PAPER DISPENSER (PROVIDE BLOCKING) 8 POLYDECK® 150SC ELASTOMERIC DECK (ESR-2785) 9 CEILING BREAK 10 SHELF & POLE 11 SHELF & DOUBLE POLE 12 LOW WALL (REFER TO PLAN FOR HEIGHT) 13 42" HIGH CRL US ALUMINUM POST & TEMP. GLAZING GUARDRAIL 14 ½" TYPE 'X' GYPSUM BOARD @ CEILING 15 GAF® EVERGUARD® SCUPPER - INSTALL PER MANUFACTURER'S SPECIFICATIONS 16 BACKING FOR ACCESSORIES 17 BACKING FOR CABINETS FLOOR PLAN KEY NOTES D01 PLANNORTH45'-91/4"27'-10"12'-10"2'-4"12'-8"24'-11/2"10'-73/4"11'-0" 45'-91/4"29'-101/2"22'-33/4"29'-01/2"21'-61/4"UP16RPROPERTY LINE 35.75'PROPERTY LINE 102.50' PROPERTY LINE 102.50'PROPERTY LINE 35.09'1 A-301 1 A-301 2 A-301 LIVING ROOM KITCHEN (E) BATH ROOM 1 (E) BEDROOM 1 GARAGE (E) DEN 27'-10"3 A-301 3 A-301 1. EFFECTIVE FLUSH VOLUME OF ALL WATER CLOSETS SHALL NOT EXCEED 1.28 GALLONS PER FLUSH 2. SHOWERHEADS SHALL HAVE A MAXIMUM FLOW RATE OF NOT MORE THAN 2.0 GALLONS PER MINUTE AT 80 PSI. 3. WHEN A SHOWER IS SERVED BY MORE THAN ONE SHOWERHEAD, THE COMBINED FLOW RATE OF ALL SHOWERHEADS AND/OR OTHER SHOWER OUTLETS CONTROLLED BY A SINGLE VALVE SHALL NOT EXCEED 2.0 GALLONS PER MINUTE AT 80 PSI. 4. THE MAXIMUM FLOW RATE OF RESIDENTIAL LAVATORY FAUCETS SHALL NOT EXCEED 1.2 GALLONS PER MINUTE AT 60 PSI. THE MINIMUM FLOW RATE OF RESIDENTIAL LAVATORY FAUCETS SHALL NOT BE LESS THAN 0.8 GALLONS PER MINUTE AT 20 PSI. 5. THE MAXIMUM FLOW RATE OF KITCHEN FAUCETS SHALL NOT EXCEED 1.8 GALLONS PER MINUTE AT 60 PSI. 6. ANNULAR SPACES AROUND PIPES, ELECTRICAL CABLES, CONDUITS, OR OTHER OPENINGS IN SOLE/BOTTOM PLATES AT EXTERIOR WALLS SHALL BE PROTECTED AGAINST THE PASSAGE OF RODENTS BY CLOSING SUCH OPENINGS WITH CEMENT MORTAR, CONCRETE MASONRY, OR SIMILAR METHOD ACCEPTABLE TO THE ENFORCING AGENCY. 7. RECYCLE AND/OR SALVAGE FOR USE A MINIMUM OF 65% OF THE NONHAZARDOUS CONSTRUCTION AND DEMOLITION WASTE IN ACCORDANCE WITH SECTION 4.408.2, 4.408.3 & 4.408.4. 8. SUBMIT A CONSTRUCTION WASTE MANAGEMENT PLAN PER SECTION 4.408.2. 9. UTILIZE A WASTE MANAGEMENT COMPANY, APPROVED BY THE CITY OF HUNTINGTON BEACH, WHICH CAN PROVIDE VERIFIABLE DOCUMENTATION THAT THE PERCENTAGE OF CONSTRUCTION AND DEMOLITION WASTE MATERIAL DIVERTED FROM THE LANDFILL COMPLIES WITH SECTION 4.408.1.10. DOCUMENTATION SHALL BE PROVIDED TO THE ENFORCING AGENCY WHICH DEMONSTRATES COMPLIANCE WITH SECTION 4.408.2, ITEMS 1 THROUGH 5, SECTION 4.408.3 OR SECTION 4.408.4. 11. AT THE TIME OF FINAL INSPECTION, A MANUAL, COMPACT DISC, WEB-BASED REFERENCE OR OTHER MEDIA ACCEPTABLE TO THE ENFORCING AGENCY PER SECTION 4.410.1, SHALL BE PROVIDED TO THE HOMEOWNER. NOTE: FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT LABELS ALL GLAZING MUST BE T-24 COMPLIANT RESIDENTIAL MANDATORY MEASURES NOTES PER 2016 CalGreen CodePLANNORTH02'4'8'SCALE: 1/4" = 1'-0"11st FLOOR PLAN 21 Total Sheet Count: 24A-103 2ND FLOOR PLANS : Plotted on 2/19/18 at 4:16 PM by Gregory Nutt. File Path: /Volumes/McNaughten Media/Kemmerer Design Arch/R-Campana/Campana ArchiCAD Models/Campana v4.2 for CDP.pln 2/19/18 A-103 2ND FLOOR PLANS1236 WEST OCEAN FRONTNEWPORT BEACH, CA 92661CAMPANA RESIDENCECOASTAL DEVELOPMENT PERMITLICE N S E D ARCHITE C T NROFILACFOETA T S IAMARC U S KEMME R E RNO. C-29552 REN: 06/30/19 ★★ Revisions: Date: Drawn by: Seal: Date:This document, and the ideas and designs incorporated here-in, asan instrument of professional service, is the property of KemmererDesign Architecture, Inc. (KDA), and is not to be used in whole orpart, for any other project without the written authorization of KDA.This document is not to be reproduced and/or modified in any way,nor shall any reproduction of the this document be modified withoutthe prior written consent of KDA.This document has been prepared to describe proposed new workand does not necessarily represent as-built or existing conditions.The architect does not warrant, in any way, the accuracy of theinformation and shall not be responsible for any discrepancybetween this document and the existing conditions.KEMMERER DESIGN ARCHITECTURE, INC.228 CREST AVENUEHUNTINGTON BEACH, CA 92648p. 714.752.0052marcus@kdarch.com/www.kdarch.comChecked by: GSN MK Job Status:DESIGN Revisions:Date: Sheet Number: Drawing: B2 A-813 A5 A-813 A2 A-813 C1 A-813 C1 A-814 B1 A-814 C2 A-814 1 42"x60" FIBERGLASS OVAL TUB ON 18" HIGH MOISTURE RESISTANT PLATFORM 2 48"X66" HAND MADE SHOWER PAN W/ TILE TO 72" A.F.F. W/ SHOWER HEAD AT +80" A.F.F. MIX WATER TO SHOWERS, SHALL BE LIMITED TO 120˚F. PROVIDE WATER TEMPERING VALVE CONFORM TO ASSE 1016 FOR SHOWERS. PROVIDE WATER TEMPERING VALVE CONFORM TO ASSE 1069 FOR GANG SHOWER. 3 HIGH EFFICIENCY TOILET (MAXIMUM 1.28 GALLONS PER FLUSH) 4 RECESSED MEDICINE CABINET (REFER TO INTERIOR ELEVATIONS) 5 SHATTER RESISTANT SHOWER ENCLOSURE FULLY TEMPERED OR LAMINATED SAFETY GLASS 6 TOWEL BAR (PROVIDE BLOCKING WHEN REQUIRED) 7 TOILET PAPER DISPENSER (PROVIDE BLOCKING) 8 POLYDECK® 150SC ELASTOMERIC DECK (ESR-2785) 9 CEILING BREAK 10 SHELF & POLE 11 SHELF & DOUBLE POLE 12 LOW WALL (REFER TO PLAN FOR HEIGHT) 13 42" HIGH CRL US ALUMINUM POST & TEMP. GLAZING GUARDRAIL 14 ½" TYPE 'X' GYPSUM BOARD @ CEILING 15 GAF® EVERGUARD® SCUPPER - INSTALL PER MANUFACTURER'S SPECIFICATIONS 16 BACKING FOR ACCESSORIES 17 BACKING FOR CABINETS FLOOR PLAN KEY NOTES D01 W01 D04 D03 PLANNORTH2 1 3 4 4 5 6 6 6 7 89 10 11 14 14 16 16 17 13B3 A-813 C2 A-81427'-10"3'-1"47'-81/4"21/4"3'-101/4"4'-01/2"4'-01/2"4'-01/2"4'-01/2"4'-01/2"3'-101/4"21/4"47'-81/4"10'-101/2"2'-51/2"2'-31/2"12'-23/4"21/4"2'-91/2"31/2"14'-5"13'-61/4"6'-51/4"13'-33/4" 17'-01/4"10'-43/4"6'-01/4"14'-23/4" 3'-0" 4'-3"9'-31/4"27'-113/4"1 A-301 1 A-301 2 A-301 TO FINISHTO FINISHSETBACKALLOWABLE 2nd FLR BALCONY ENCROACHMENT (E) MASTER BEDROOM (N) MASTER BATH (N) BALCONY(E) CLOSETALIGNSLOPE ¼"PER FOOTSLOPE ¼"PER FOOTEE E UP17RDN16R(E) BATH ROOM 2 (N) MASTER CLOSET (E) BEDROOM 3 (E) BEDROOM 4 E E E E PROPERTY LINE 35.75'PROPERTY LINE 102.50' PROPERTY LINE 102.50'PROPERTY LINE 35.09'E 11 16 D02 A3 A-813 C1 A-814 B1 A-814 7'-91/2"5'-7"3'-01/2"3 A-301 3 A-301 1. EFFECTIVE FLUSH VOLUME OF ALL WATER CLOSETS SHALL NOT EXCEED 1.28 GALLONS PER FLUSH 2. SHOWERHEADS SHALL HAVE A MAXIMUM FLOW RATE OF NOT MORE THAN 2.0 GALLONS PER MINUTE AT 80 PSI. 3. WHEN A SHOWER IS SERVED BY MORE THAN ONE SHOWERHEAD, THE COMBINED FLOW RATE OF ALL SHOWERHEADS AND/OR OTHER SHOWER OUTLETS CONTROLLED BY A SINGLE VALVE SHALL NOT EXCEED 2.0 GALLONS PER MINUTE AT 80 PSI. 4. THE MAXIMUM FLOW RATE OF RESIDENTIAL LAVATORY FAUCETS SHALL NOT EXCEED 1.2 GALLONS PER MINUTE AT 60 PSI. THE MINIMUM FLOW RATE OF RESIDENTIAL LAVATORY FAUCETS SHALL NOT BE LESS THAN 0.8 GALLONS PER MINUTE AT 20 PSI. 5. THE MAXIMUM FLOW RATE OF KITCHEN FAUCETS SHALL NOT EXCEED 1.8 GALLONS PER MINUTE AT 60 PSI. 6. ANNULAR SPACES AROUND PIPES, ELECTRICAL CABLES, CONDUITS, OR OTHER OPENINGS IN SOLE/BOTTOM PLATES AT EXTERIOR WALLS SHALL BE PROTECTED AGAINST THE PASSAGE OF RODENTS BY CLOSING SUCH OPENINGS WITH CEMENT MORTAR, CONCRETE MASONRY, OR SIMILAR METHOD ACCEPTABLE TO THE ENFORCING AGENCY. 7. RECYCLE AND/OR SALVAGE FOR USE A MINIMUM OF 65% OF THE NONHAZARDOUS CONSTRUCTION AND DEMOLITION WASTE IN ACCORDANCE WITH SECTION 4.408.2, 4.408.3 & 4.408.4. 8. SUBMIT A CONSTRUCTION WASTE MANAGEMENT PLAN PER SECTION 4.408.2. 9. UTILIZE A WASTE MANAGEMENT COMPANY, APPROVED BY THE CITY OF HUNTINGTON BEACH, WHICH CAN PROVIDE VERIFIABLE DOCUMENTATION THAT THE PERCENTAGE OF CONSTRUCTION AND DEMOLITION WASTE MATERIAL DIVERTED FROM THE LANDFILL COMPLIES WITH SECTION 4.408.1.10. DOCUMENTATION SHALL BE PROVIDED TO THE ENFORCING AGENCY WHICH DEMONSTRATES COMPLIANCE WITH SECTION 4.408.2, ITEMS 1 THROUGH 5, SECTION 4.408.3 OR SECTION 4.408.4. 11. AT THE TIME OF FINAL INSPECTION, A MANUAL, COMPACT DISC, WEB-BASED REFERENCE OR OTHER MEDIA ACCEPTABLE TO THE ENFORCING AGENCY PER SECTION 4.410.1, SHALL BE PROVIDED TO THE HOMEOWNER. NOTE: FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT LABELS ALL GLAZING MUST BE T-24 COMPLIANT RESIDENTIAL MANDATORY MEASURES NOTES PER 2016 CalGreen CodePLANNORTH02'4'8'SCALE: 1/4" = 1'-0"12nd FLOOR PLAN 22 Total Sheet Count: 24A-104 ROOF DECK PLAN : Plotted on 2/19/18 at 4:16 PM by Gregory Nutt. File Path: /Volumes/McNaughten Media/Kemmerer Design Arch/R-Campana/Campana ArchiCAD Models/Campana v4.2 for CDP.pln 2/19/18 A-104 ROOF DECK PLAN1236 WEST OCEAN FRONTNEWPORT BEACH, CA 92661CAMPANA RESIDENCECOASTAL DEVELOPMENT PERMITLICE N S E D ARCHITE C T NROFILACFOETA T S IAMARC U S KEMME R E RNO. C-29552 REN: 06/30/19 ★★ Revisions: Date: Drawn by: Seal: Date:This document, and the ideas and designs incorporated here-in, asan instrument of professional service, is the property of KemmererDesign Architecture, Inc. (KDA), and is not to be used in whole orpart, for any other project without the written authorization of KDA.This document is not to be reproduced and/or modified in any way,nor shall any reproduction of the this document be modified withoutthe prior written consent of KDA.This document has been prepared to describe proposed new workand does not necessarily represent as-built or existing conditions.The architect does not warrant, in any way, the accuracy of theinformation and shall not be responsible for any discrepancybetween this document and the existing conditions.KEMMERER DESIGN ARCHITECTURE, INC.228 CREST AVENUEHUNTINGTON BEACH, CA 92648p. 714.752.0052marcus@kdarch.com/www.kdarch.comChecked by: GSN MK Job Status:DESIGN Revisions:Date: Sheet Number: Drawing: D05 W02 PLANNORTH1 A-301 1 A-301 2 A-301 19'-71/2"8'-0"5'-51/2"5'-51/2"10'-0" 10'-0"10'-103/4"DN17R(N) ROOF DECK(N) 3:12ROOF SLOPE(N) 3:12ROOF SLOPEP A T H O F T R A V E L = 3 8 ' - 7 "PROPERTY LINE 35.75'PROPERTY LINE 102.50' PROPERTY LINE 102.50'PROPERTY LINE 35.09'3 A-301 3 A-301 0 2'4'8'SCALE: 1/4" = 1'-0"1ROOF DECK PLAN 23 Total Sheet Count: 24A-201 ELEVATIONS : Plotted on 2/19/18 at 4:16 PM by Gregory Nutt. File Path: /Volumes/McNaughten Media/Kemmerer Design Arch/R-Campana/Campana ArchiCAD Models/Campana v4.2 for CDP.pln 2/19/18 A-201 ELEVATIONS1236 WEST OCEAN FRONTNEWPORT BEACH, CA 92661CAMPANA RESIDENCECOASTAL DEVELOPMENT PERMITLICE N S E D ARCHITE C T NROFILACFOETA T S IAMARC U S KEMME R E RNO. C-29552 REN: 06/30/19 ★★ Revisions: Date: Drawn by: Seal: Date:This document, and the ideas and designs incorporated here-in, asan instrument of professional service, is the property of KemmererDesign Architecture, Inc. (KDA), and is not to be used in whole orpart, for any other project without the written authorization of KDA.This document is not to be reproduced and/or modified in any way,nor shall any reproduction of the this document be modified withoutthe prior written consent of KDA.This document has been prepared to describe proposed new workand does not necessarily represent as-built or existing conditions.The architect does not warrant, in any way, the accuracy of theinformation and shall not be responsible for any discrepancybetween this document and the existing conditions.KEMMERER DESIGN ARCHITECTURE, INC.228 CREST AVENUEHUNTINGTON BEACH, CA 92648p. 714.752.0052marcus@kdarch.com/www.kdarch.comChecked by: GSN MK Job Status:DESIGN Revisions:Date: Sheet Number: Drawing: NEW DECK ROOF TEMP. GLASS GUARD GUARD RAIL GUARD RAIL TEMP. GLASS GUARD 13.38' 12.91' 31.62' 34.94' EXISTING FIN. FLOOR TOP OF RAIL/GUARD TOP DECK FS 32.98'RIDGE 40.69'RIDGE 12.19' AVERAGE GRADE NEW ROOF DECK GUARDRAIL TEMP. GLASS GUARDGUARDRAIL TEMP. GLASS GUARD 13.38' 12.73' 31.62' 32.98' EXISTING FIN. FLOOR RIDGE TOP DECK FS 40.69'RIDGE 12.19' AVERAGE GRADE C2 A-814 3'-6" TYP.21/2"3'-73/4"21/2"3'-6", TYP.4'-01/2" TYP. GUARDRAIL D01 D01 GUARDRAILTEMPERED GLASS GUARD EXISTING FIN. FLOOR TEMPERED GLASS GUARD TOP OF RAIL/GUARD EXISTING FIN. FLOOR 3"12" 13.38' 12.73' 13.38' 12.91' 31.62' 34.94' TOP DECK RIDGE40.69' 12.19' AVERAGE GRADE 12.19' AVERAGE GRADE 3"12"31/2"TYP.C1 A-814 B1 A-814 0 2'4'8'SCALE: 1/4" = 1'-0"2EAST ELEVATION 0 2'4'8'SCALE: 1/4" = 1'-0"3WEST ELEVATION 0 2'4'8'SCALE: 1/4" = 1'-0"1SOUTH ELEVATION NOTE: ESTABLISHED GRADE BASED ON AVERAGE OF FOUR CORNERS AND A SLOPE OF LESS THAN 5% PER ZONING SECTION 21.30.050. FOUR CORNERS USED ARE 12.91'. 12.73', 11.67', AND 11.45'. CALCULATED AVERAGE GRADE SHOWN NOTED ON ELEVATIONS. 24 Total Sheet Count: 24A-301 SECTIONS : Plotted on 2/19/18 at 4:16 PM by Gregory Nutt. File Path: /Volumes/McNaughten Media/Kemmerer Design Arch/R-Campana/Campana ArchiCAD Models/Campana v4.2 for CDP.pln 2/19/18 A-301 SECTIONS 1236 WEST OCEAN FRONTNEWPORT BEACH, CA 92661CAMPANA RESIDENCECOASTAL DEVELOPMENT PERMITLICE N S E D ARCHITE C T NROFILACFOETA T S IAMARC U S KEMME R E RNO. C-29552 REN: 06/30/19 ★★ Revisions: Date: Drawn by: Seal: Date:This document, and the ideas and designs incorporated here-in, asan instrument of professional service, is the property of KemmererDesign Architecture, Inc. (KDA), and is not to be used in whole orpart, for any other project without the written authorization of KDA.This document is not to be reproduced and/or modified in any way,nor shall any reproduction of the this document be modified withoutthe prior written consent of KDA.This document has been prepared to describe proposed new workand does not necessarily represent as-built or existing conditions.The architect does not warrant, in any way, the accuracy of theinformation and shall not be responsible for any discrepancybetween this document and the existing conditions.KEMMERER DESIGN ARCHITECTURE, INC.228 CREST AVENUEHUNTINGTON BEACH, CA 92648p. 714.752.0052marcus@kdarch.com/www.kdarch.comChecked by: GSN MK Job Status:DESIGN Revisions:Date: Sheet Number: Drawing: (N) ⅝" DRYWALL CEILING FLOOR JOISTS SEE STRUCTUAL TEMPERED GLAZING GUARDRAIL MASTER BEDROOM LIVING ROOM 13.38' 31.62' 34.94' EXISTING FIN. FLOOR TOP OF RAIL/GUARD TOP DECK 12.19' AVERAGE GRADE 31/2"3'-01/2"2"3'-6"3'-6"MASTER BEDROOM LIVING ROOM 13.38' 31.62' 34.94' 40.69' EXISTING FIN. FLOOR TOP OF RAIL/GUARD TOP DECK RIDGE 12.19' AVERAGE GRADE C1 A-814 B4 A-8133'-6"6'-8"1'-43/4" 33/4" MATCH EXISTING 42"ROOF RAFTERS SEE STRUCTURAL ROOF SHEATHING SEE STRUCTURAL CLASS A ROOFING TILE CEILING JOIST SEE STRUCTURAL 2X10 RESAWN EAVES & RAKES RIDGE BOARD SEE STRUCTURAL HEADER SEE STRUCT ⅝" GYP BOARD⅝" GYP BOARD 13.38' 31.62' 34.94' 40.69' EXISTING FIN. FLOOR TOP OF RAIL/GUARD TOP DECK RIDGE 12.19' AVERAGE GRADE 3"12"3"12"6'-8"6'-8"101/4"61/2"(E)101/4"(E)61/2"(E)33/4" OPEN TREADS, TYP. 0 2'4'8'SCALE: 1/4" = 1'-0"1SECTION A 0 2'4'8'SCALE: 1/4" = 1'-0"2SECTION B 0 2'4'8'SCALE: 1/4" = 1'-0"3SECTION THRU STAIRS RISERS & TREADS NEW STANDARD RESIDENTIAL STAIRWAY: EACH RISER SHALL NOT BE MORE THAN 7¾" HIGH. THE TREADS SHALL BE A MINIMUM OF 10" DEEP FROM THE FRONT TO THE BACK (NOT COUNTING THE PART UNDERNEATH THE NOSING OF THE TREAD ABOVE). THE NOSING MUST PROJECT AT LEAST ¾", BUT NOT MORE THAN 1¼". THE STEPS IN A FLIGHT OF STAIRS NEED TO BE UNIFORM TO AVOID TRIPPING. THE CODE ALLOWS ONLY ⅜" DIFFERENCE BETWEEN THE LARGEST AND THE SMALLEST RISE, AND ONLY ⅜" DIFFERENCE BETWEEN THE LARGEST AND THE SMALLEST TREAD MEASURED FROM FRONT TO BACK. 2016 CRC R311.7.5.(1)(2). DIMENSIONAL TOLERANCES THE LARGEST TREAD DEPTH OR RISER HEIGHT WITHIN ANY STAIRWAY SHALL NOT EXCEED THE SMALLEST BY MORE THAN ⅜". 2016 CRC R311.7.5.1. 25 Zoning Administrator - April 12, 2018 ITEM NO. 5a - ADDITIONAL MATERIALS Campana Residence Coastal Development Permit (PA2017-263)