Loading...
HomeMy WebLinkAbout06_Coronado Residence Coastal Development Permit_PA2018-119CITY OF NEWPORT BEACH ZONING ADMINISTRATOR STAFF REPORT SUBJECT: Coronado Residence (PA2018-119) Coastal Development Permit No. CD2018-052 SITE LOCATION: 309 Coronado Street APPLICANT: Sepulveda Builders, Inc. OWNER: 309 Coronado, LLC PLANNER: Liane Schuller, Contract Planner 949-644-3237, Ischuller@newportbeachca.gov LAND USE AND ZONING June 28, 2018 Agenda Item No.6 • General Plan: RS -D (Single -Unit Residential Detached) • Zoning District : R-1 (Single -Unit Residential) • Coastal Land Use Category: RSD -D (Single -Unit Residential Detached, 20.0 - 29.9 DU/AC) • Coastal Zoning District: R-1 (Single -Unit Residential) PROJECT SUMMARY The applicant requests a coastal development permit (CDP) to allow the demolition of an existing single-family residence, and the construction of a new three-story, 2,200 -square - foot, single-family residence and attached 420 -square -foot, two -car garage. The project will include hardscape, landscape and subsurface drainage facilities all located within the confines of private property. The design complies with all applicable development standards and no deviations are requested. All improvements are shown on the attached project plans (Attachment No. ZA 4). RECOMMENDATION 1) Conduct a public hearing; 2) Find this project exempt from the California Environmental Quality Act (CEQA) pursuant to Section 15303 under Class 3 (New Construction or Conversion of Small Structures), because it has no potential to have a significant effect on the environment; and 3) Adopt Draft Zoning Administrator Resolution No. _ approving Coastal Development Permit No. CD2018-052 (Attachment No. ZA 1). 1 Coronado Residence (PA2018-119) Zoning Administrator, June 28, 2018 Page 2 Land Use and Development Standards • The project is located in the R-1 Zoning District, which allows single-family residential development, and is consistent with the City's Coastal Land Use Plan, General Plan, and Zoning Code. A CDP is required as the property is not eligible for a Waiver for De Minimis Development because the property is located in the Appeal Area. The property consists of one legal lot containing an existing single-family residence. The neighborhood is predominantly developed with one- to three-story residential structures. Newer residences may have a rooftop deck and a partial third story. The design, bulk, and scale of the proposed development is consistent with the existing and anticipated neighborhood pattern of development. The proposed single-family residence and accessory structures conform to all applicable development standards, including floor area limit, setbacks, height, and off-street parking as evidenced by the project plans and illustrated in Table 1 below: Table 1 — Development Standards Development Standard Standard Proposed Setbacks (min.) Front(along Coronado 9 feet 9 feet Sides 3 feet 3 feet Rear(along aIle 5 feet 5 feet Floor Area 2,688 square feet 2,620 square feet Open Volume Area 202 square feet 347 square feet Allowable Third Floor Area 269 square feet 260 square feet Parking 2 -car garage 2 -car garage Height 24 feet flat roof 29 feet sloped roof 24 feet flat roof 29 feet sloped roof Hazards The project site is located approximately 350 feet from the Newport Bay and is separated from the water by an alleyway and other developed residential lots. • The finished first floor elevation of the proposed residence is 9.00 feet based on the North American Vertical Datum of 1988 (NAVD88) elevation standard, which complies with the minimum required 9 -foot (NAVD88) elevation standard. The property is located in an area known for the potential of seismic activity and liquefaction. All projects are required to comply with the California Building Code (CBC) and Building Division standards and policies. Geotechnical investigations specifically addressing liquefaction are required to be reviewed and approved prior to the issuance of building permits. Permit issuance is also contingent on the 9 Coronado Residence (PA2018-119) Zoning Administrator, June 28, 2018 Page 3 inclusion of design mitigation identified in the investigations. Construction plans are reviewed for compliance with approved investigations and CBC prior to building permit issuance. Water Quality • The project design addresses water quality with a construction erosion control plan that outlines temporary Best Management Practices (BMPs) to be implemented during construction to minimize erosion and sedimentation, and to minimize pollution runoff derived by construction chemicals and materials. No water quality impacts to coastal waters are anticipated based upon the location and elevation of the property. • The property is not located on the shoreline nor is it located within 100 feet of coastal waters. The project design addresses water quality with a construction erosion control plan and a post construction drainage system that includes drainage and percolation features designed to retain dry weather and minor rain event run-off on- site. Any water not retained on-site is directed to the City's storm drain system. Public Access The project site is located on the Balboa Peninsula, between the nearest public road and the sea or shoreline. The existing residential development neither provides nor inhibits public coastal access. Implementation Plan Section 21.30A.040 (Determination of Public Access/Recreation Impacts) requires that the provision of public access bear a reasonable relationship between the requirement and the project's impact and be proportional to the impact. In this case, the project replaces an existing single-family residence with a new single-family residence. Therefore, the project does not involve a change in land use, density or intensity that will result in increased demand on public access and recreation opportunities. Furthermore, the project is designed and sited so as not to block or impede existing public access opportunities. The residential lot does not currently provide nor does it inhibit public coastal access. Lateral coastal access is provided along Edgewater Avenue East, approximately 350 feet north of the project site. Vertical access to the bay front is provided at multiple street ends throughout the neighborhood, including the Coronado Street end. The project site is not located adjacent to a coastal view road, public viewpoint, public park or beach, or public accessway, as identified in the Coastal Land Use Plan. Furthermore, an evaluation of the project site and surrounding area did not identify any other nearby public view opportunities. The project site may be located within the viewshed of distant public viewing areas. However, the project will replace an existing single-family residence with a new single-family residence that complies with all applicable Local Coastal Program development standards and maintains a building envelope consistent with the anticipated pattern of development. Therefore, the 3 Coronado Residence (PA2018-119) Zoning Administrator, June 28, 2018 Page 4 project does not have the potential to degrade the visual quality of the Coastal Zone or result in significant adverse impacts to public views. ENVIRONMENTAL REVIEW This project is exempt from the California Environmental Quality Act (CEQA) pursuant to Section 15303 under Class 3 (New Construction or Conversion of Small Structures) of the CEQA Guidelines, California Code of Regulations, Title 14, Chapter 3, because it has no potential to have a significant effect on the environment. Class 3 exempts the construction and location of limited numbers of new, small facilities or structures including one single-family residence in a residential zone. The proposed project consists of the demolition of an existing single-family residence, and the construction of a new three-story, 2,200 -square -foot, single-family residence and attached 420 -square -foot, two -car garage in the R-1 Zoning District. PUBLIC NOTICE Notice of this public hearing was published in the Daily Pilot, mailed to all owners and residential occupants of property within 300 feet of the boundaries of the site (excluding intervening rights-of-way and waterways), including the applicant, and posted on the subject property at least 10 days before the scheduled hearing, consistent with the provisions of the NBMC. Additionally, the item appeared on the agenda for this meeting, which was posted at City Hall and on the City website. APPEAL PERIOD: This action shall become final and effective 14 days following the date the Resolution is adopted unless within such time an appeal or call for review is filed with the Community Development Director in accordance with the provisions of Title 21 (Local Coastal Implementation Plan) of the Newport Beach Municipal Code. Final action taken by the City may be appealed to the Coastal Commission in compliance with Section 21.64.035 of the City's certified LCP and Title 14 California Code of Regulations, Sections 13111 through 13120, and Section 30603 of the Coastal Act. For additional information on filing an appeal, contact the Planning Division at 949-644-3200. Prepared by: lne Schu lertract Planner RU/Is 0 Attachments Coronado Residence (PA2018-119) Zoning Administrator, June 28, 2018 Page 5 ZA 1 Draft Resolution ZA 2 Vicinity Map ZA 3 Project Description and Justification ZA 4 Project Plans 5 Attachment No. ZA 1 Draft Resolution 0 RESOLUTION NO. ZA2018-### A RESOLUTION OF THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH, CALIFORNIA APPROVING COASTAL DEVELOPMENT PERMIT NO. CD2018-052 TO DEMOLISH AN EXISTING SINGLE-FAMILY RESIDENCE AND CONSTRUCT A NEW THREE-STORY, SINGLE-FAMILY RESIDENCE WITH AN ATTACHED TWO -CAR GARAGE AT 309 CORONADO STREET (PA2018-119) THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH HEREBY FINDS AS FOLLOWS: SECTION 1. STATEMENT OF FACTS. 1. An application was filed by Sepulveda Builders, Inc. ("Applicant"), on behalf of 309 Coronado, LLC, the property owner, with respect to property located at 309 Coronado Street, requesting approval of a coastal development permit. 2. The property is legally described as Lot 45 of Tract 511, in the City of Newport Beach, County of Orange, State of California. 3. The Applicant proposes to demolish an existing single-family residence and construct a new three-story, 2,200 -square -foot, single-family residence with an attached 420 -square - foot, two -car garage. The project will include hardscape, landscape, and subsurface drainage facilities all located within the confines of private property. The design complies with all applicable development standards and no deviations are requested. 4. The subject property is designated RS -D (Single -Unit Residential Detached) by the General Plan Land Use Element and is located within the R-1 (Single -Unit Residential) Zoning District. 5. The subject property is located within the coastal zone. The Coastal Land Use Plan category is RSD -D (Single -Unit Residential Detached, 20.0 — 29.9 DU/AC) and the property is located within the R-1 (Single -Unit Residential) Coastal Zone District. 6. A public hearing was held on June 28, 2018, in the Corona del Mar Conference Room (Bay E-1 st Floor) at 100 Civic Center Drive, Newport Beach. A notice of time, place, and purpose of the hearing was given in accordance with the Newport Beach Municipal Code. Evidence, both written and oral, was presented to, and considered by, the Zoning Administrator at this hearing. SECTION 2. CALIFORNIA ENVIRONMENTAL QUALITY ACT DETERMINATION. 1. This project is categorically exempt pursuant to Title 14 of the California Code of Regulations Section 15303, Article 19 of Chapter 3, Guidelines for Implementation of the California Environmental Quality Act ("CEQA') under Class 3 (New Construction or Zoning Administrator Resolution No. ZA2018-### Paqe 2 of 7 Conversion of Small Structures), because it has no potential to have a significant effect on the environment. 2. Class 3 exempts the construction and location of limited numbers of new, small facilities or structures including one single-family residence in a residential zone. The proposed project consists of the demolition of an existing single-family residence and the construction of a new 2,200 -square -foot single-family residence and attached 420 - square -foot, two -car garage in the R-1 Zoning District. SECTION 3. REQUIRED FINDINGS. In accordance with Newport Beach Municipal Code ("NBMC) Section 21.52.015 (Coastal Development Permits, Findings and Decision), the following findings and facts in support of such findings are set forth: Finding: A. Conforms to all applicable sections of the certified Local Coastal Program. Facts in Support of Finding: 1. The proposed development complies with applicable residential development standards including, but not limited to, floor area limitation, setbacks, height, and parking. a. The total proposed floor area, including the residence and enclosed parking, is 2,620 square feet, which complies with the maximum allowable floor area limit of 2,688 square feet. b. The proposed development will provide the minimum required setbacks, which are nine (9) feet along the front property line abutting Coronado Street, three (3) feet along each side property line, and five (5) feet along the rear property line abutting the alley. c. The highest guardrail is no more than 24 feet and the highest roof ridge is no more than 29 feet, measured from the established grade level of 9.00 feet based on the North American Vertical Datum of 1988 ("NAVD88"), which complies with the maximum height limitation. d. The project includes enclosed garage parking for two vehicles, in compliance with the minimum parking requirement for single-family residences with less than 4,000 square feet of habitable floor area. 2. The neighborhood is predominantly developed with one- to three-story residential structures. Newer residences may have a rooftop deck and a partial third story. The design, bulk, and scale of the proposed development is consistent with the existing and anticipated neighborhood pattern of development. 3. The project site is located approximately 350 feet from the Newport Bay and is separated from the water by an alleyway and other developed residential lots. The finished first floor I Zoning Administrator Resolution No. ZA2018-### Paqe 3 of 7 elevation of the proposed residence is 9.00 feet based on the North American Vertical Datum of 1988 (NAVD88) elevation standard, which complies with the minimum required 9 -foot (NAVD88) elevation standard. 4. The property is located in an area known for the potential of seismic activity and liquefaction. All projects are required to comply with the California Building Code (CBC) and Building Division standards and policies. Geotechnical investigations specifically addressing liquefaction are required to be reviewed and approved prior to the issuance of building permits. Permit issuance is also contingent on the inclusion of design mitigation identified in the investigations. Construction plans are reviewed for compliance with approved investigations and CBC prior to building permit issuance. 5. The project design addresses water quality with a construction erosion control plan that outlines temporary Best Management Practices (BMPs) to be implemented during construction to minimize erosion and sedimentation, and to minimize pollution runoff derived by construction chemicals and materials. No water quality impacts to coastal waters are anticipated based upon the location and elevation of the property. 6. The property is not located on the shoreline nor is it located within 100 feet of coastal waters. The project design addresses water quality with a construction erosion control plan and a post construction drainage system that includes drainage and percolation features designed to retain dry weather and minor rain event run-off on-site. Any water not retained on-site is directed to the City's storm drain system. 7. New landscaping will be verified for compliance with NBMC Section 21.30.075 (Landscaping). Condition of Approval No. 11 is included to require drought -tolerant, and prohibits invasive, species. Prior to issuance of the building permits, the final landscape plans will be reviewed to verify invasive species are not planted. 8. The property is not located near a designated public viewpoint, is not near a coastal view road as designated by the Local Coastal Plan, and will not impact public coastal views. Finding: B. Conforms with the public access and public recreation policies of Chapter 3 of the Coastal Act if the project is located between the nearest public road and the sea or shoreline of any body of water located within the coastal zone. Fact in Support of Finding: The project site is located on the Balboa Peninsula, between the nearest public road and the sea or shoreline, and the existing residential development neither provides nor inhibits public coastal access. Implementation Plan Section 21.30A.040 (Determination of Public Access/Recreation Impacts) requires that the provision of public access bear a reasonable relationship between the requirement and the project's impact and be proportional to the impact. In this case, the project replaces an existing single-family residence with a new single-family residence. Therefore, the project does not involve a change in land use, 0 Zoning Administrator Resolution No. ZA2018-### Paqe 4 of 7 density or intensity that will result in increased demand on public access and recreation opportunities. 2. The residential lot does not currently provide nor does it inhibit public coastal access. Lateral coastal access is provided along Edgewater Avenue East, approximately 350 feet north of the project site. Vertical access to the bay front is provided at multiple street ends throughout the neighborhood, including the Coronado Street end. The proposed project does not alter or affect existing public coastal access conditions. 3. The project site is not located adjacent to a coastal view road, public viewpoint, public park or beach, or public accessway, as identified in the Coastal Land Use Plan. Furthermore, an evaluation of the project site and surrounding area did not identify any other nearby public view opportunities. The project site may be located within the viewshed of distant public viewing areas. However, the project will replace an existing single-family residence with a new single-family residence that complies with all applicable Local Coastal Program development standards and maintains a building envelope consistent with the anticipated pattern of development. Therefore, the project does not have the potential to degrade the visual quality of the Coastal Zone or result in significant adverse impacts to public views. SECTION 4. DECISION. NOW, THEREFORE, BE IT RESOLVED: The Zoning Administrator of the City of Newport Beach hereby approves Coastal Development Permit No. CD2018-052, subject to the conditions set forth in Exhibit which is attached hereto and incorporated by reference. 2. This action shall become final and effective 14 days following the date this Resolution was adopted unless within such time an appeal or call for review is filed with the Community Development Director in accordance with the provisions of Title 21 Local Coastal Implementation Plan, of the Newport Beach Municipal Code. Final action taken by the City may be appealed to the Coastal Commission in compliance with Section 21.64.035 of the City's certified LCP and Title 14 California Code of Regulations, Sections 13111 through 13120, and Section 30603 of the Coastal Act. PASSED, APPROVED, AND ADOPTED THIS 28TH DAY OF JUNE, 2018. Patrick J. Alford, Zoning Administrator 10 Zoning Administrator Resolution No. ZA2018-### Pace 5 of 7 EXHIBIT "A" CONDITIONS OF APPROVAL 1. The development shall be in substantial conformance with the approved site plan, floor plans and building elevations stamped and dated with the date of this approval (except as modified by applicable conditions of approval). 2. Revisions to the approved plans may require an amendment to this Coastal Development Permit or the processing of a new coastal development permit. 3. Coastal Development Permit No. CD2018-052 shall expire unless exercised within 24 months from the date of approval as specified in NBMC Section 21.54.060 (Time Limits and Extensions), unless an extension is otherwise granted. 4. The project is subject to all applicable City ordinances, policies, and standards, unless specifically waived or modified by the conditions of approval. 5. The Applicant shall comply with all federal, state, and local laws. Material violation of any of those laws in connection with the use may be cause for revocation of this Coastal Development Permit. 6. This Coastal Development Permit may be modified or revoked by the Zoning Administrator if determined that the proposed uses or conditions under which it is being operated or maintained is detrimental to the public health, welfare or materially injurious to property or improvements in the vicinity or if the property is operated or maintained so as to constitute a public nuisance. 7. Best Management Practices (BMPs) and Good Housekeeping Practices (GNPs) shall be implemented prior to and throughout the duration of construction activity as designated in the Construction Pollution Prevention Plan (CPPP). 8. Prior to issuance of a building permit, a copy of the Resolution, including conditions of approval Exhibit "A" shall be incorporated into the Building Division and field sets of plans. 9. Prior to issuance of a building permit, the Applicant shall submit to the Planning Division an additional copy of the approved architectural plans for inclusion in the Coastal Development Permit file. The plans shall be identical to those approved by all City departments for building permit issuance. The approved copy shall include architectural sheets only and shall be reduced in size to 11 inches by 17 inches. The plans shall accurately depict the elements approved by this Coastal Development Permit. 10. Prior to issuance of a building permit, the applicant shall submit a final construction erosion control plan. The plan shall be subject to review and approval by the Building Division. 11 Zoning Administrator Resolution No. ZA2018-### Paqe 6 of 7 11. Prior to the issuance of a building permit, the Applicant shall submit a final landscape and irrigation plan. These plans shall incorporate drought tolerant plantings, non- invasive plant species, and water efficient irrigation design. The plans shall be approved by the Planning Division. 12. All landscape materials and irrigation systems shall be maintained in accordance with the approved landscape plan. All landscaped areas shall be maintained in a healthy and growing condition and shall receive regular pruning, fertilizing, mowing, and trimming. All landscaped areas shall be kept free of weeds and debris. All irrigation systems shall be kept operable, including adjustments, replacements, repairs, and cleaning as part of regular maintenance. 13. Prior to the issuance of a building permit, the Applicant shall pay any unpaid administrative costs associated with the processing of this application to the Planning Division. 14. No demolition or construction materials, equipment debris, or waste, shall be placed or stored in a location that would enter sensitive habitat, receiving waters, or a storm drain or result in impacts to environmentally sensitive habitat areas, streams, wetland or their buffers. 15. The discharge of any hazardous materials into storm sewer systems or receiving waters shall be prohibited. Machinery and equipment shall be maintained and washed in confined areas specifically designed to control runoff. A designated fueling and vehicle maintenance area with appropriate berms and protection to prevent spillage shall be provided as far away from storm drain systems or receiving waters as possible. 16. Debris from demolition shall be removed from work areas each day and removed from the project site within 24 hours of the completion of the project. Stock piles and construction materials shall be covered, enclosed on all sites, not stored in contact with the soil, and located as far away as possible from drain inlets and any waterway. 17. Trash and debris shall be disposed in proper trash and recycling receptacles at the end of each construction day. Solid waste, including excess concrete, shall be disposed in adequate disposal facilities at a legal disposal site or recycled at a recycling facility. 18. Should the property be sold or otherwise come under different ownership, any future owners or assignees shall be notified of the conditions of this approval by the current property owner or agent. 19. To the fullest extent permitted by law, Applicant shall indemnify, defend and hold harmless City, its City Council, its boards and commissions, officials, officers, employees, and agents from and against any and all claims, demands, obligations, damages, actions, causes of action, suits, losses, judgments, fines, penalties, liabilities, costs and expenses (including without limitation, attorney's fees, disbursements and court costs) of every kind and nature whatsoever which may arise from or in any manner relate (directly or indirectly) to City's approval of Coronado Residence Coastal Development Permit including, but not limited to, Coastal Development Permit No. CD2018-052 (PA2018-119). This indemnification 12 Zoning Administrator Resolution No. ZA2018-### Paqe 7 of 7 shall include, but not be limited to, damages awarded against the City, if any, costs of suit, attomeys' fees, and other expenses incurred in connection with such claim, action, causes of action, suit or proceeding whether incurred by Applicant, City, and/or the parties initiating or bringing such proceeding. The Applicant shall indemnify the City for all of City's costs, attomeys' fees, and damages, which City incurs in enforcing the indemnification provisions set forth in this condition. The Applicant shall pay to the City upon demand any amount owed to the City pursuant to the indemnification requirements prescribed in this condition. 13 Attachment No. ZA 2 Vicinity Map 14 VICINITY MAP Coastal Development Permit No. CD2018-052 PA2018-119 309 Coronado Street 15 Attachment No. ZA 3 Project Description and Justification 1( Coastal Development Permit Application PROJECT DESCRIPTION AND JUSTIFICATION Community Development Department / Planning Division 100 Civic Center Drive Newport Beach, Ca 92658 Project Description: 309 Coronado Street, Newport Beach Ca 92661 (APN: 048-102-19) Construct a new three story single family residence with attached two car garage. Existing property is bordered by a three story single family residence on each side, existing street with curb and gutter at the front and an alley to the rear. Property is served by all public utilities. Site storm water and drainage has been designed by a licensed civil engineer to filtrate run off water. New three story residence - 2,620 square feet Number of bedrooms - 4 New 2 Car Garage - 420sf Building Height - 29ft Total Landscape - 142ft Project will include demolishing an existing 2 story single family residence Existing side yard walls will be replaced. A solis report has been prepared by soils engineer, EGA Consultants and included with this application. Removal of existing single family residence to be replaced with single family residence has no effect on public or private recreational opportunities. 17 Attachment No. ZA 4 Project Plans 12 GENERAL NOTES 1. ALL CONSTRUCTION SHALL COMPLY WITH THE 2016 CBC, CEC, CPC, CMC, AND ALL LOCAL CODES AND ORDINANCES & 2016 CALIFORNIA RESIDENTIAL CODE. 2. A STAMPED SET OF APPROVED PLANS SHALL BE KEPT AT THE JOB SITE AT ALL TIMES. 3. THE CONTRACTOR SHALL VISIT THE JOB SITE AND VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS. PRIOR TO THE COURSE OF CONSTRUCTION. 4. ANY DISCREPANCIES BETWEEN THE DRAWINGS AND THE ACTUAL SET OF DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER AND DESIGNER PRIOR TO PROCEEDING WITH CONSTRUCTION. 5. THE CONTRACTOR IS RESPONSIBLE FOR PROTECTING ANY ON-SITE UTILITIES FROM DAMAGE DURING THE COURSE OF CONSTRUCTION. 6. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE RESIDENCE OVER SCALED DIMENSIONS. 7. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY PERMITS AND INSPECTION, OTHER THEN PLAN CHECK AND BUILDING PERMIT FEES PROVIDED BY THE OWNER. 8. ALL EQUIPMENT, WORK AND MATERIALS SHALL COMPLY WITH ALL APPLICABLE CODES AND GOVERNING AGENCIES. 9. THE CONTRACTOR SHALL MAINTAIN LIABILITY INSURANCE TO PROTECT HIMSELF AND HOLD THE DESIGNER AND OWNER HARMLESS FROM ANY CLAIM FOR DAMAGES FOR INJURY OR PROPERTY DAMAGE DURING THE COURSE OF THE CONTRACT. 10. FIRE INSURANCE SHALL BE MAINTAINED BY THE OWNER. 11. TEMPORARY POWER, WATER, WORKERS TOILET FACILITIES AND MATERIAL STORAGE SHALL BE PROVIDED BY THE CONTRACTOR. 12. THE CONTRACTOR SHALL PROTECT ALL FINISHED WORK AND ADJACENT SURFACES FROM DAMAGE DURING COURSE OF CONSTRUCTION AND SHALL REPLACE AND OR REPAIR ANY AND ALL DAMAGES CAUSED BY THE WORKERS OR DUE TO CONSTRUCTION. 13. ALL CONSTRUCTION WASTE AND DEBRIS MUST BE CONTAINERIZED AT ALL TIMES. UPON COMPLETION OF THE WORK ALL AREAS SHALL BE LEFT BROOM SWEPT AND ALL DEBRIS SHALL BE REMOVED FROM THE SITE. 14. DIMENSIONS ON FLOOR PLANS, SECTIONS AND DETAILS ARE SHOWN TO THE FACE OF STUD, CENTERLINE OF COLUMN, FACE OF MASONRY, FACE. 15. DOOR LOCATIONS NOT ESTABLISHED BY DIMENSIONS SHALL BE CENTERED IN WALL OR BE LOCATED 4 1/2" FROM ADJACENT WALL TO ALLOW FOR DOOR CASING. 16. NAILING FOR DIAPHRAGMS AND SHEAR WALLS MUST BE INSPECTED PRIOR TO COVERING. 17. NAILING INSPECTION IS REQUIRED FOR ALL GYPSUM AND LATH AFTER INSTALLATION BEFORE TAPING AND FINISHING, CORNERS BEADS TO BE NAILED. GYPSUM BOARD SPACING TO BE 3/8" MAXIMUM. GYPSUM AND LATH SHALL BE NAILED TO ALL STUDS AND TO TOP AND BOTTOM PLATES. 18. PROVIDE HOUSE STREET NUMBER VISIBLE AND LEGIBLE FROM STREET BEFORE, DURING AND AFTER CONSTRUCTION. 19. THE RESIDENCE COMPLIES WITH STATE ENERGY STANDARDS TITLE 24 PART 6. 20. POOLS, SPAS, WALLS, FENCES, PATIO COVERS AND OTHER FREE STANDING STRUCTURES REQUIRE SEPARATE REVIEWS AND PERMITS. 21. RESIDENCE TO COMPLY WITH 2016 CBC REGARDING THE PROTECTION OF PEDESTRIANS DURING CONSTRUCTION. PLUMBING REQUIREMENTS FOR ALL NEW BUILDINGS OR REMODELS THAT INVOLVE PLUMBING FIXTURES ARE REQUIRED TO HAVE THE FLOW RATES AS LISTED BELOW: THE FLOW RATE REQUIREMENTS ARE PER THE 2016 CALIFORNIA PLUMBING CODE SECTION 403.0 & 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE SECTION 4.303. 22. ALL REMODELED HOME ARE TO UPGRADE ALL TOILETS / WATER CLOSETS: 1.28 GALLONS PER FLUSH. URINALS: 0.5 GALLONS PER FLUSH BATHROOM / LAVATORY FAUCETS: 1.5 GALLONS PER MINUTE AT 60PSI KITCHEN FAUCETS: 1.8 GALLONS PER MINUTE AT 60PSI. PER 2016 CALIFORNIA GREEN CODE. 23. POOLS, SPAS, WALLS, FENCES, PATIO COVERS AND OTHER FREE STANDING STRUCTURES REQUIRE SEPARATE REVIEWS AND PERMITS. 24. FENCES, HEDGES, WALLS, RETAINING WALLS, GUARDRAILS AND HANDRAILS OR ANY COMBINATION THEREOF SHALL NOT EXCEED 42 INCHES FROM EXISTING GRADE PRIOR TO CONSTRUCTION WITHIN THE REQUIRED FRONT SETBACK. 25. I. m 6'-2„ CONCRETE WALKWAY iii LINE OF 2ND FLOOR - ----77- PROPERTY LINE 70.05' I I SITE PLAN va - r-0.. VICINITY MAP TYPICAL TOILET MINIMUM CLARENCE REQUIREMENTS in m Lo L J CLEARANCE FOR WATER CLOSETS TO BE A MINIMUM OF 24" IN FRONT ND 15" FROM CENTER TO ANY SIDE WALL OR OBSTRUCTION. EXISTING SINGLE FAMILY RESIDENCE TRASH TRASH CAN CAN E I�hl�i]�c7:U]�SiZ�7:1 LINE OF GARAGE WALL FIREPLACE PROJECTION �E LINE OF 3RD FLOOR L 2 CAR GARAGE NEW SINGLE FAMILY RESIDENCE 1 ST FLOOR ELEV 9'-0" 25-0" STAIRWELL LANDSCAPE EXISTING SINGLE FAMILY RESIDENCE J 16'-9" O O LLJ 0 z N LL O w Z J in PROPERTY LINE 70.04' i+> 309 CORONADO ST MAXIMUM BUILDABLE AREA: O TOTAL STORIES: Z OCCUPANCY TYPE: GROUP R3/U 24,-0" VB - SPRINKLER APN: 048-102-19 e < GARAGE 420 SQ FT SECOND FLOOR: •�. Nw0.T M' C ,Y. ay.0 e.a ~o O _ ^•e .. m ronuGmm � TOTAL: RomaniW rnmm.QQ -. MINIMUM OPEN SPACE REQUIRED: 0 BUILDING SECTIONS OPEN SPACE REQUIRED: O FIRST FLOOR SIZE: 101 SQ FT K 123 SQ FT TOTAL: O 0 DECK SPACE: w 123 SQ FT THIRD FLOOR: Z TOTAL: 1,049 SQ FT 42" TOP - TYPICAL TOILET MINIMUM CLARENCE REQUIREMENTS in m Lo L J CLEARANCE FOR WATER CLOSETS TO BE A MINIMUM OF 24" IN FRONT ND 15" FROM CENTER TO ANY SIDE WALL OR OBSTRUCTION. EXISTING SINGLE FAMILY RESIDENCE TRASH TRASH CAN CAN E I�hl�i]�c7:U]�SiZ�7:1 LINE OF GARAGE WALL FIREPLACE PROJECTION �E LINE OF 3RD FLOOR L 2 CAR GARAGE NEW SINGLE FAMILY RESIDENCE 1 ST FLOOR ELEV 9'-0" 25-0" STAIRWELL LANDSCAPE EXISTING SINGLE FAMILY RESIDENCE J 16'-9" O O LLJ 0 z N LL O w Z J in PROPERTY LINE 70.04' i+> GATE 10'-2" m O O O M w z_ J H W a a SCOPE OF WORK NEW 2 CAR GARAGE, 4 BEDROOMS AND ROOF TOP DECK GENERAL INFORMATION JOB ADDRESS: 309 CORONADO ST MAXIMUM BUILDABLE AREA: O TOTAL STORIES: Z OCCUPANCY TYPE: GROUP R3/U 24,-0" VB - SPRINKLER APN: 048-102-19 789 SQ FT GARAGE 420 SQ FT SECOND FLOOR: 1,151 SQ FT O 260 SQ FT TOTAL: U- MINIMUM OPEN SPACE REQUIRED: 0 BUILDING SECTIONS OPEN SPACE REQUIRED: O FIRST FLOOR SIZE: 101 SQ FT K 123 SQ FT TOTAL: O 0 DECK SPACE: w 123 SQ FT THIRD FLOOR: Z TOTAL: 1,049 SQ FT 42" TOP - W OF WALL SECTION CUT CALLOUT FRONT PATIO STONE ON Lu W O CONCRETE PAD GFCI NEW GROUND -FAULT CIRCUIT GATE 10'-2" m O O O M w z_ J H W a a SCOPE OF WORK NEW 2 CAR GARAGE, 4 BEDROOMS AND ROOF TOP DECK GENERAL INFORMATION JOB ADDRESS: 309 CORONADO ST MAXIMUM BUILDABLE AREA: NEWPORT BEACH, CA 92661 TOTAL STORIES: THREE STORY OCCUPANCY TYPE: GROUP R3/U CONST. TYPE: VB - SPRINKLER APN: 048-102-19 SHEETINDEX LOT SIZE: 2,099 SQ FT MAXIMUM BUILDABLE AREA: PROJECT DATA, SITE PLAN 1344 X 2 = 2688 SQ FT Al MAXIMUM THIRD FLOOR BUILDABLE SPACE: 1344 X 20% = 268.8 SQ FT A2 MAXIMUM TOTAL SQ FT: 2,688 SQ FT FIRST HABITABLE FLOOR SIZE: 789 SQ FT GARAGE 420 SQ FT SECOND FLOOR: 1,151 SQ FT THIRD FLOOR: 260 SQ FT TOTAL: 2,620 SQ FT MINIMUM OPEN SPACE REQUIRED: 1344 X 15% = 201.6 BUILDING SECTIONS OPEN SPACE REQUIRED: 202 SQ FT FIRST FLOOR SIZE: 101 SQ FT SECOND FLOOR: 123 SQ FT TOTAL: 224 SQ FT DECK SPACE: SECOND FLOOR: 123 SQ FT THIRD FLOOR: 926 SO FT TOTAL: 1,049 SQ FT TOTAL LANDSCAPE: 142 SQ FT ARCHITECTURAL SURVEY A0 PROJECT DATA, SITE PLAN SITE SURVEY Al DEMOLITION SITE PLAN 375-C MONTE VISTA AVENUE A2 SITE DRAINAGE PLAN EROSION A3 FLOOR SPACE AND AREA G-04 A4 FIRST AND SECOND FLOOR PLANS 1 A5 THIRD FLOOR PLAN DOORTAG A6 EXTERIOR ELEVATIONS A7 BUILDING SECTIONS A8 ROOF PLAN AFCI A9 DETAILS A10 FIRST AND SECOND FLOOR ELECTRICAL PLANS All THIRD FLOOR ELECTRICAL PLAN Al2 CITY REQUIRED SHEETS PROJECT TEAM/OWNER CONTACT INFORMATION OWNER SEPULVEDA BUILDERS INC. BRENT AND JAMI SEPULVEDA 790 NEWTON WAY COSTA MESA, CA 92627 714.288.0732 LAND SURVEY RdM SURVEYING INC. RON MIEDEMA 23016 LAKE FOREST DRIVE #409 LAGUNA HILLS, CA 92653 949.858.2924 I F(,FNn 1:10cly NP [Ke] 0111108111111 ZI A_P I DESIGNER SOILS ENGINEER JJAB DESIGN EGA CONSULTANTS, INC. JASON BLACKMORE DAVID WORTHINGTON 2736 DE SOTO AVE 375-C MONTE VISTA AVENUE COSTA MESA, CA 92626 COSTA MESA, CALIFORNIA 92627 949.274.6585 949.642.9309 I�]quN]�IIN]il3�1�Nllq NEW WORK KEYNOTE EXISTING WALL ===== DEMOLITION WALL 2735 DE SOTO AVE. COSTA MESA, CA 92626 949.274.6585 JJABDESIGN@GMAIL.COM JASON BLACKMORE CONTENT SITE PLAN AND PROJECT INFORMATION PREPARED BY JJB PROJECT 180201 DATE 05.29.2018 SHEET 19 (q) WINDOW TAG NEW WALL 1 DOORTAG (m nn NEW DUPLEX AFCI NEW ARC -FAULT CIRCUIT INTERRUPTER DUPLEX W SECTION CUT CALLOUT Lu W O 2 GFCI NEW GROUND -FAULT CIRCUIT 0� INTERRUPTER DUPLEX PROJECT W A2.1 NEW 3 STORY 4 BEDROOM L) O Z O SMOKE DETECTOR - UL 217 H/C/G �� VALVE - HOT/COLD/GAS RESIDENCE O Q RATED 309 CORONADO STREET U z SMOKE/CARBON MONOXIDE DOWN LIGHT NEWPORT BEACH, CA 92661 DETECTOR - UL 2034/2075 O CO RATED LIGHT SWITCH CLIENT 0 FAN VENT -50CFM MIN SEPULVEDA BUILDERS, INC 790 NEWTON WAY COSTA MESA, CA 92627 CONTENT SITE PLAN AND PROJECT INFORMATION PREPARED BY JJB PROJECT 180201 DATE 05.29.2018 SHEET 19 EXISTING SINGLE FAMILY RESIDENCE 1 ) SITE PLAN - DEMOLITION I I I 0 0 0 co Lu I z J } ry LLI D_ I ry d I 1 I J J J I J I 1 I I I Y J >Q W 0 U) W H W U Z O U 2735 DE SOTO AVE. COSTA MESA, CA 92626 949.274.6585 JJABDESIGN@GMAIL.COM JASON BLACKMORE i4� PROJECT NEW 3 STORY 4 BEDROOM RESIDENCE 309 CORONADO STREET NEWPORT BEACH, CA 92661 CLIENT SEPULVEDA BUILDERS, INC 790 NEWTON WAY COSTA MESA, CA 92627 CONTENT DEMOLITION SITE PLAN PREPARED BY JJB PROJECT 180201 DATE 05.29.2018 SHEET Al I I I SLOPE I F w IL coJ I I r O I m I I la 0 co 0 OI 0 M W IL _Z J 0 rn � I LW 3 0 SLOPE d PROPERTY LINE 70.05' I I I SITE PLAN - DRAINAGE 2 CAR GARAGE SLOPE EXISTING SINGLE FAMILY RESIDENCE CONCRETE WALKWAY LINE OF 3RD FLOOR SLOPE —1E LINE OF 3RD FLOOR NEW SINGLE FAMILY RESIDENCE SLOPE LANDSCAPE 1ST FLOOR ELEV 9'-0" SLOPE EXISTING SINGLE FAMILY RESIDENCE SLOPE 2735 DE SOTO AVE. COSTA MESA, CA 92626 949.274.6585 JJABDESIGN@GMAIL.COM JASON BLACKMORE f4� PROJECT NEW 3 STORY 4 BEDROOM RESIDENCE 309 CORONADO STREET NEWPORT BEACH, CA 92661 CLIENT SEPULVEDA BUILDERS, INC 790 NEWTON WAY COSTA MESA, CA 92627 CONTENT DRAINAGE SITE PLAN PREPARED BY JJB PROJECT 180201 DATE 05.29.2018 SHEET A2 21 PROPERTY LINE 70.04' SLOPE O SLOPE CD O co W Z_ J } Lu IL w z LL I= ofLL' O w O I0 cr 0 o 0 o O J LuY Z a w oz J FRONT PATIO w W W a STONE ON 0 0 CONCRETE PAD co w w w co Z O J I O z w O J O SLOPE 2735 DE SOTO AVE. COSTA MESA, CA 92626 949.274.6585 JJABDESIGN@GMAIL.COM JASON BLACKMORE f4� PROJECT NEW 3 STORY 4 BEDROOM RESIDENCE 309 CORONADO STREET NEWPORT BEACH, CA 92661 CLIENT SEPULVEDA BUILDERS, INC 790 NEWTON WAY COSTA MESA, CA 92627 CONTENT DRAINAGE SITE PLAN PREPARED BY JJB PROJECT 180201 DATE 05.29.2018 SHEET A2 21 �7 � '=717= 4 6 5'1' 20'-T 524 C 6',' 2,688 SQ FT FIRST HABITABLE FLOOR SIZE: ++ PIA 420 SO FT ++ 1,151 SQ FT THIRD FLOOR: ++ TOTAL: 2,620 SQ FT `.IME m ON ING ROOM 1344 X 15% = 201.6 Y � OPEN SPACE REQUIRED: 202 SQ FT +W mm�.m L1.1. SECOND FLOOR: 0 1 TOTAL: 224 SQ FT + U IN) MSTR 123 SQ FT <4#. (N) KITCHEN + U LL I� THROOM 91 AY'�, ■' _sae_ �. OI+ !4 1A A�® @ ■� _ Jill .�1�sholl g �/ I. W ® km 0'a IN' CLET 5'1' 20'-T 524 C 6',' 9_1 -DE HABITABLE SPACE J UNHABITABLE GARAGE SPACE EXCLUDED STAIR SPACE J OPEN SPACE + + DECK SPACE o' 2.V 2,688 SQ FT FIRST HABITABLE FLOOR SIZE: ++ PIA 420 SO FT ++ 1,151 SQ FT THIRD FLOOR: ++ TOTAL: 2,620 SQ FT `.IME m ON 1344 X 15% = 201.6 Y � OPEN SPACE REQUIRED: 202 SQ FT +W EmigC=« SECOND FLOOR: 0 1 TOTAL: 224 SQ FT + U IN) MSTR 123 SQ FT <4#. 926 SQ FT + U LL 1,049 SQ FT THROOM 91 Zdj [1)+aDO W �:. �. OI+ !4 1A A�® @ ■� _ Jill .�1�sholl g �/ I. W ® km 0'a IN' CLET 9_1 -DE HABITABLE SPACE J UNHABITABLE GARAGE SPACE EXCLUDED STAIR SPACE J OPEN SPACE + + DECK SPACE o' 2.V 2,688 SQ FT FIRST HABITABLE FLOOR SIZE: ++ GARAGE 420 SO FT ++ 1,151 SQ FT THIRD FLOOR: ++ TOTAL: 2,620 SQ FT ++ 1344 X 15% = 201.6 Y � OPEN SPACE REQUIRED: 202 SQ FT +W 101 SQ FT SECOND FLOOR: 0 1 TOTAL: 224 SQ FT + U SECOND FLOOR: 123 SQ FT THIRD FLOOR: 926 SQ FT + U LL 1,049 SQ FT Zdj [1)+aDO W �. OI+ !4 + SQUARE FOOT BREAKDOWN MAXIMUM TOTAL SQ FT: 2,688 SQ FT FIRST HABITABLE FLOOR SIZE: 789 SQ FT GARAGE 420 SO FT SECOND FLOOR: 1,151 SQ FT THIRD FLOOR: 260 SQ FT TOTAL: 2,620 SQ FT MINIMUM OPEN SPACE REQUIRED: 1344 X 15% = 201.6 �L m -M tl{ OPEN SPACE REQUIRED: 202 SQ FT FIRST FLOOR SIZE: 101 SQ FT SECOND FLOOR: 123 SQ FT TOTAL: 224 SQ FT DECK SPACE: SECOND FLOOR: 123 SQ FT THIRD FLOOR: 926 SQ FT TOTAL: 1,049 SQ FT TOTAL LANDSCAPE: 142 SQ FT 0 N b'f'IGlY 12'-5" 5" 6-5" V 16'1 14'-11" 5'1 '-0" 524" 12'v T 5' 6' S' 16' 2' 14.4 P 57 2-0• 14 15 2 1s in, 18 ' aI 2'a' VANEW 1'-1" 2735 DE SOTO AVE. COSTA MESA, CA 92626 949.274.6585 JJABDESIGN@GMAIL.COM JASON BLACKMORE PROJECT NEW 3 STORY 4 BEDROOM RESIDENCE 309 CORONADO STREET NEWPORT BEACH, CA 92661 CLIENT SEPULVEDA BUILDERS, INC 790 NEWTON WAY COSTA MESA, CA 92627 CONTENT FLOOR SPACE AND AREA PREPARED BY JJB PROJECT 180201 DATE 05.29.2018 SHEET A3 �L m -M tl{ �. !4 @ Wim^ Jill .�1�sholl �/ W ® CLST 2'a' VANEW 1'-1" 2735 DE SOTO AVE. COSTA MESA, CA 92626 949.274.6585 JJABDESIGN@GMAIL.COM JASON BLACKMORE PROJECT NEW 3 STORY 4 BEDROOM RESIDENCE 309 CORONADO STREET NEWPORT BEACH, CA 92661 CLIENT SEPULVEDA BUILDERS, INC 790 NEWTON WAY COSTA MESA, CA 92627 CONTENT FLOOR SPACE AND AREA PREPARED BY JJB PROJECT 180201 DATE 05.29.2018 SHEET A3 GENERALNOTES KEYNOTES 1. ALL BATHROOM TO HAVE A EXHAUST FAN 50 CFM WITH HUMIDISTAT CONTROL 1. 3/4 HP GARAGE DOOR OPENER 2. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION 2. OUTDOOR SHOWER WITH HOT AND COLD WATER AND SANITARY DRAIN. HOT 3. BATHROOM / LAVATORY FAUCETS: 1.5 GALLONS PER MINUTE AT 60PSI 2 MOP AND TILE PAN. TILE WALLS TO CEILING. 4. SINGLE HEAD SHOWER / BATHTUB: 1.8 GALLONS PER MINUTE AT 80PSI MULTIPLE 3. MINIMUM 18 PLATFORM BELOW FAU. 2'-8" SHOWER HEADS SERVING ONE SHOWER: THE FLOW RATE OF ALL SHOWER HEADS 4. PROVIDE 2 - 14"X 12" LOUVERED VENTS WITH 1/4" GALVANIZED MESH 4 COMBINED AT 2.0 GALLONS PER MINUTE AT 80PSI, CONTROLLED BY A SINGLE 8'-0" SCREENING. ONE WITH 12" OF CEILING, ONE 12" ABOVE PLATFORM. T-0" VALUE, OR SHOWER SHALL BE DESIGNED TO ALLOW ONLY ONE SHOWER HEAD OR 5. KITCHEN CABINETS - UPPERS AND LOWERS. 1 3/4" OUTLET TO BE IN OPERATION AT A TIME. 6. KITCHEN SINK WITH GARBAGE DISPOSAL. 5. TOILETS / WATER CLOSETS: 1.28 GALLONS PER FLUSH. 7. CABINET DEPTH REFRIGERATOR WITH UPPERS ABOVE. 6. KITCHEN FAUCETS: 1.8 GALLONS PER MINUTE AT 60PSI B. 5/8" TYPE "X" GYP ON ALL WALLS AND CEILING BELOW STAIR 7. 5/8" TYPE "X" GYPSUM WALL BOARD IN ALL LOCATIONS. 9. SINK CABINET WITH SOLID STONE SURFACE. 8. THE NET AREA OF THE SHOWER ENCLOSURE SHALL BE 1,024 SQ. INCHES (7.1 SQ. 10. TALL LINEN CABINET. 11/2" FT.) OR MORE IN CLEAR FLOOR AREA, AND SHALL ALSO BE CAPABLE OF 13. RATED WALL ASSEMBLY SEE DETAIL 2/A9. 6-8" ENCOMPASSING A 30" DIAMETER CIRCLE. CPC 411.7 14. RATED WALL ASSEMBLY SEE DETAIL 3/A9. 9. WALL COVERING OF SHOWERS SHALL BE CEMENT PLASTER, TILE OR APPROVED 15. RATED CEILING ASSEMBLY SEE DETAIL 4/A9. 12 EQUAL TO A HEIGHT OF 70" ABOVE DRAIN INLET PROVIDE CEMENT BOARD OR 16. DEX-O-TEX WEATHERWEAR ROOF DECK COVERING - ESR -1757 CEMENT PLASTER BACKING FOR TILE. CPC 407.5 10. EXTERIOR LATH AND PLASTER: PROVIDE 2 LAYERS OF GRADED PAPER OVERALL WOOD BASE SHEATHING. CBC 2510.6 11. PROVIDE CLOTHES DRYER MOISTURE DUCT (4" MIN DIA) TO THE OUTSIDE AND DOOR SCHEDULE #0 EQUIPPED WITH A BACK -DRAFT DAMPER. THE CLOTHES DRYER VENT SHALL NOT EXCEED 14'-0" IN OVER ALL LENGTH WITH 2 ELBOWS. CMC 504.3.2 12. SMOKE ALARMS AND CARBON MONOXIDE ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING, SHALL BE EQUIPPED WITH BATTERY BACKUP AND INTERCONNECTED PER R314.3, R314.4 AND R315.1 13. GUARDRAIL 42" MIN. FROM FLOOR. DESIGN PER OWNER. GRILLWORK OR BALUSTERS SHALL BE SPACED SUCH THAT A 4" SPHERE CANNOT PASS THRU. THE OPEN SPACE BETWEEN BOTTOM ELEMENT OF GUARDRAIL SHALL NOT ALLOW A 4" SPHERE TO PASS THROUGH. 17. 14"X6" G.I. SCREENED VENT 6" ABOVE FLOOR IN GARAGE. (1 -PER CAR) 11. DOUBLE SINK WITH 1/ 2 HP. GARBAGE DISPOSAL (WITH AIR GAP FOR DISHWASHER) 12. DISHWASHER WITH AIR GAP- VERIFY DIMENSIONS WITH MANUFACTURER'S SPECIFICATIONS 13. PROVIDE WEATHER -RESISTANT GYPSUM WALLBOARD AT ALL ROOMS SUBJECT TO MOISTURE, WATER CLOSET COMPARTMENTS, LAUNDRY ROOMS AND WALLS WITH PLUMBING FIXTURES. 14. CEMENT, FIBER -CEMENT OR GLASS MAT GYPSUM BACKERS IN COMPLIANCE WITH ASTM C1288,C1288 OR C1325 SHALL BE USED AS A BASE FOR WALL TILE IN TUB AND SHOWERAREAS AND CEILING AND WALL PANELS IN SHOWER AREAS. WATER- RESISTANT GYPSUM BACKING BOARD SHALL BE USED AS A BASE FOR TILE IN WATER CLOSET COMPARTMENT WALLS WHEN INSTALLED IN ACCORDANCE WITH GA -216 OR ASTM C840 REGULAR GYPSUM WALLBOARD IS PERMITTED UNDER TILE OR WALL PANELS IN OTHER WALL AND CEILING AREAS WHEN INSTALLED IN ACCORDANCE WITH GA -216 OR ASTM C840. WATER-RESISTANT GYPSUM BOARD SHALL NOT BE USED IN THE FOLLOWING LOCATIONS: (CBC 2509.2) OVER A VAPOR RETARDER. IN AREAS SUBJECT TO HIGH HUMIDITY, SUCH AS SAUNAS, STEAM ROOMS OR GANG SHOWER ROOMS. DOOR SCHEDULE, FRAME TYPE & WINDOW GENERAL NOTES 1. CONTRACTOR TO FIELD VERIFY ALL SIZES AND TYPES PRIOR TO ORDERING WINDOWS AND DOORS. 2. WINDOW EMERGENCY ESCAPE AND RESCUE OPENING PER R310.1 - WHERE EMERGENCY ESCAPE AND RESCUE OPENINGS ARE PROVIDED THEY SHALL HAVE THE BOTTOM OF THE CLEAR OPENING NOT GREATER THAN 44 INCHES (1118 MM) MEASURED FROM THE FLOOR. WINDOWS MINIMUM NET CLEAR OPENING OF 5.7 FEET, THE MINIMUM NET CLEAR OPENING WIDTH SHALL BE 20 INCHES (508 MM). WINDOW MINIMUM NET CLEAR OPENING HEIGHT SHALL BE 24 INCHES (610 MM). 3. ALL DOORS SHALL BE 1-3/4" THICK UNLESS NOTED OTHERWISE. 4. ALL INTERIOR DOORS SHALL BE UNDERCUT 3/4" A.F.F. UNLESS NOTED OTHERWISE. 5. TEMPERED GLASS IS REQUIRED IN ALL LOCATIONS ESTABLISHED BY THE IBC. THOSE ARE AS FOLLOWS: 1. ALL GLAZING IN DOORS. 2. GLAZING WITHIN 24" OF THE EDGE OF A DOOR AND THE BOTTOM EDGE OF GLASS IS LESS THAN 18" ABOVE THE WALKING SURFACE. 3. ANY GLAZING THAT MEETS ALL FOUR OF THE FOLLOWING CRITERIA: THE BOTTOM EDGE IS LESS THAN 18" ABOVE WALKING SURFACE, AND THE PANE IS GREATER THAN 9 SQUARE FEET, AND THE TOP EDGE IS GREATER THAN 36" ABOVE WALKING SURFACE, AND A WALKING SURFACE IS WITHIN 36" OF THE OPENING. (THE OUTBOARD PANE OF INSULATED GLASS UNITS DOES NOT NEED TO BE TEMPERED IF THE BOTTOM EDGE OF GLASS IS 25' OR MORE ABOVE GRADE.) 4. ALL GLAZING IN GUARDS AND RAILINGS. 5. ANY GLAZING WITHIN 60" OF A STAIRWAY, LANDING, OR RAMP IF THE BOTTOM EDGE IS LESS THAN 60" ABOVE WALKING SURFACE (ONLY IF NO GUARDRAIL IS PROVIDED). 6. ANY GLAZING WITHIN 60" HORIZONTALLY OF THE BOTTOM TREAD OF A STAIRWAY IF THE BOTTOM EDGE IS LESS THAN 60" ABOVE THE NOSE OF THE TREAD (ONLY IF NO GUARDRAIL IS PROVIDED). 7. ALL GLASS SHOWER DOORS. 6. REFER TO THE FLOOR PLANS FOR EXACT LOCATIONS OF DOORS AND DIRECTION OF DOOR SWINGS. 7. VERIFY ALL DIMENSIONS IN FIELD PRIOR TO FABRICATION. 8. DIMENSIONS SHOWN ARE NOMINAL AND/OR ROUGH OPENINGS, CONTRACTOR TO ACCOUNT FOR JOINTS, SHIMS, SEALANT, ETC. 9. SOME FRAME TYPES ARE REPEATED AS SIMILAR OR OPPOSITE. SEE ELEVATIONS OR PLANS FOR QUANTITIES, LOCATIONS AND INSTALLATION. 10. LANDINGS OR FINISH FLOORS AT THE REQUIRED EGRESS DOOR SHALL NOT BE MORE THAN 1-1/2" LOWER THAN THE TOP OF THE THRESHOLD. CRC 311.1 MARK WD SIZE HGT THK NOTES 1 T-6" 8'-0" 13/4" T-6" 2 12'-0" 8'-0" 1 1/2" TEMPERED GLASS 3 2'-8" 8'-0" 11/2" 5 4 2'-8" 8'-0" 11/2" T-0" 5 T-0" 8'-0" 1 3/4" SOLID CORE OR 20 MIN.RATED DOOR WITH SELF-CLOSING DEVICE. 6 T-0" 8'-0" 13/4" CASEMENT - 7 16-0" T-0" 11/2" 10 8 2'-8" 6'-B" 11/2" 6-0" 9 4'-0" 6-8" 1 11/2" 4'-0" 10 10'-0" 6-8" 1 1/2" TEMPERED GLASS 11 2'-8" 6-8" 11/2" 15 12 2'-8" 6-8" 11/2" 2'-0" 13 T-0" 6-8" 11/2" 2'-0" 14 2'-8" 6-8" 11/2" CASEMENT 15 T-0" 6-8" 11/2" 20 16 6-4" 6-8" 11/4" T-0" 17 T-0" 6'-8" 11/2" 5-0" 18 64" 6-8" 11/4" FIXED - 19 2'-8" 6-8" 11/2" * SEE DETAIL 5/A9 FOR WEATHER PROOFING OPENINGS 20 2'-8" 6-8" 11/2" 21 8'-0" 6-8" 1 1/2" TEMPERED GLASS 22 2'-0" 6-8" 11/2" ? Az 23 2'-8" 6-8" 11/2" 2'-8" 6'-B" 11/2" I I F24 *SEE DETAIL 5/A9 FOR WEATHER PROOFING OPENINGS WINDOW SCHEDULE <#> MARK SIZE Width HEIGHT TYPE NOTES 1 T-0" 6'-0" CASEMENT - 2 2'-0" T-6" FIXED - 3 T-0" 5'-0" FIXED 4 8'-0" 4'-0" CASEMENT 5 T-10" T-10" FIXED - 6 T-0" 5'-0" FIXED 7 T-0" 5'-0" FIXED 8 T-0" 5'-0" CASEMENT - 9 2'-0" 2'-0" CASEMENT - 10 2'-0" T-0" CASEMENT - 11 6-0" 4'-0" CASEMENT 12 6'4" 4'-0" CASEMENT 13 2'-0" 2'-0" CASEMENT 14 2'-0" 2'-0" CASEMENT 15 4'-0" 1'-6" CASEMENT 16 2'-0" 2'-0" CASEMENT 17 2'-0" 2'-0" CASEMENT 18 8'-0" T-0" CASEMENT 19 3'4" 5'-0" FIXED 20 3'-0" 5-0" FIXED 21 T-0" 5'-0" FIXED 22 2'-0" 5-0" FIXED 23 2'-0" 5-0" FIXED - * SEE DETAIL 5/A9 FOR WEATHER PROOFING OPENINGS TOTAL LIGHTING AREA CALCULATION LIVING ROOM, DINNING ROOM AND KITCHEN - 543 /146 = 0.27 BEDROOM #1 - 237 / 91 = 0.38 BEDROOM #2 - 131 /24=0.18 BEDROOM #3 - 131 / 24 = 0.18 BEDROOM #4 - 194 / 53 = 0.27 OPERABLE VENTILATION AREA CALCULATION LIVING ROOM, DINNING ROOM AND KITCHEN - 543 / 114 = 0.21 BEDROOM #1 - 237 / 70 = 0.30 BEDROOM #2 - 131 /24=0.18 BEDROOM #3 - 131 / 24 = 0.18 BEDROOM #4-194/36=0.19 LEGEND EXISTING WALL NEW WALL VALVE - HOT/COLD/GAS SHB HOSE BIB I I 2 I I 2'-7" 1 52'-4 12'-5" 2'-5" 6'-5" 16'-2" 14'-11" 13 14 PROJECT 15 z 13 As 16 17 3 18 3 SHEET ��fl �� 18 a �-fl �� TUB A4 (N) BAT HRO M #2 g� (N) BEDROOM #2 m N) MSTR a °i B b HROOM #1 w Z v (N) CLST 6'-5" 9'-9" ¢ o 13 17 � 12 Ln in CABINE 11 (N) MSTER BEDROOM #1 15 13'-5" 6'-11" in 08 v S 15'-2" 6', Q 14 47 09 (N) BEDROOM #3 (N) LST % H 3 m9 0 8( ALK -IN MSTR o � CLST LZ 1 - - As 1g I 0 ? Az I I , 2 j 3 10 9 188 As 7 O As 12'-5" 2'-5" 8'-1" 17'-3" T - SECOND FLOOR PLAN lV4..-�_o. 779� - -TT - OUTDOOR ICONDENSER HB HOWE 2 in 06 I 1 A6 SECOND FLOOR ABOVE (N)GARAGE 0 N 07 --LEJ ib I 15 As 20'-T' FIRST FLOOR PLAN 1 % 1/4" = T-0' 4 I -I INSTA FA,- WH j'� 131 14 2:) 13 A6 (N) KITCHEN L-� 5 DW nb 04 S �� 151 U) 17,_0„ (N) DINING ROOM 03 7'-� 5T- 2r01 - 3 m 0 (N) LIVING ROOM \3/ V 5'-11 "v �W6-2 A 01 9,_1,. DECK OVERHANG' WITH L GHTING 1 A6 b I 02 I I I 4 m 4 A6 vo I 6'-1" i L 2735 DE SOTO AVE. COSTA MESA, CA 92626 949.274.6585 JJABDESIGN@GMAIL.COM JASON BLACKMORE PROJECT NEW 3 STORY 4 BEDROOM RESIDENCE 309 CORONADO STREET NEWPORT BEACH, CA 92661 CLIENT SEPULVEDA BUILDERS, INC 790 NEWTON WAY COSTA MESA, CA 92627 CONTENT FIRST AND SECOND FLOOR PLANS PREPARED BY JJB PROJECT 180201 DATE 05.29.2018 SHEET A4 z GENERALNOTES 1. ALL BATHROOM TO HAVE A EXHAUST FAN 50 CFM WITH HUMIDISTAT CONTROL 2. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION 3. BATHROOM / LAVATORY FAUCETS: 1.5 GALLONS PER MINUTE AT 60PSI 4. SINGLE HEAD SHOWER / BATHTUB: 1.8 GALLONS PER MINUTE AT 80PSI MULTIPLE SHOWER HEADS SERVING ONE SHOWER: THE FLOW RATE OF ALL SHOWER HEADS COMBINED AT 2.0 GALLONS PER MINUTE AT 80PSI, CONTROLLED BY A SINGLE VALUE, OR SHOWER SHALL BE DESIGNED TO ALLOW ONLY ONE SHOWER HEAD OR OUTLET TO BE IN OPERATION AT A TIME. 5. TOILETS / WATER CLOSETS: 1.28 GALLONS PER FLUSH. 6. KITCHEN FAUCETS: 1.8 GALLONS PER MINUTE AT 60PSI 7. 5/8" TYPE "X" GYPSUM WALL BOARD IN ALL LOCATIONS. 8. THE NET AREA OF THE SHOWER ENCLOSURE SHALL BE 1,024 SQ. INCHES (7.1 SQ. FT.) OR MORE IN CLEAR FLOOR AREA, AND SHALL ALSO BE CAPABLE OF ENCOMPASSING A 30" DIAMETER CIRCLE. CPC 411.7 9. WALL COVERING OF SHOWERS SHALL BE CEMENT PLASTER, TILE OR APPROVED EQUAL, TO A HEIGHT OF 70" ABOVE DRAIN INLET. PROVIDE CEMENT BOARD OR CEMENT PLASTER BACKING FOR TILE. CPC 407.5 10. EXTERIOR LATH AND PLASTER: PROVIDE 2 LAYERS OF GRADE D PAPER OVER ALL WOOD BASE SHEATHING. CBC 2510.6 11. PROVIDE CLOTHES DRYER MOISTURE DUCT (4" MIN DIA) TO THE OUTSIDE AND EQUIPPED WITH A BACK -DRAFT DAMPER. THE CLOTHES DRYER VENT SHALL NOT EXCEED 14'-0" IN OVER ALL LENGTH WITH 2 ELBOWS. CMC 504.3.2 12. SMOKE ALARMS AND CARBON MONOXIDE ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING, SHALL BE EQUIPPED WITH BATTERY BACKUP AND INTERCONNECTED PER R314.3, R314.4 AND R315.1 13. GUARDRAIL 42" MIN. FROM FLOOR. DESIGN PER OWNER. GRILLWORK OR BALUSTERS SHALL BE SPACED SUCH THAT A 4" SPHERE CANNOT PASS THRU. THE OPEN SPACE BETWEEN BOTTOM ELEMENT OF GUARDRAIL SHALL NOT ALLOW A 4" SPHERE TO PASS THROUGH. 17. 14"X6" G.I. SCREENED VENT 6" ABOVE FLOOR IN GARAGE. (1 -PER CAR) 11. DOUBLE SINK WITH 1/ 2 HP. GARBAGE DISPOSAL (WITH AIR GAP FOR DISHWASHER) 12. DISHWASHER WITH AIR GAP- VERIFY DIMENSIONS WITH MANUFACTURER'S SPECIFICATIONS 13. PROVIDE WEATHER -RESISTANT GYPSUM WALLBOARD AT ALL ROOMS SUBJECT TO MOISTURE, WATER CLOSET COMPARTMENTS, LAUNDRY ROOMS AND WALLS WITH PLUMBING FIXTURES. 14. CEMENT, FIBER -CEMENT OR GLASS MAT GYPSUM BACKERS IN COMPLIANCE WITH ASTM C1288,C1288 OR C1325 SHALL BE USED AS A BASE FOR WALL TILE IN TUB AND SHOWERAREAS AND CEILING AND WALL PANELS IN SHOWER AREAS. WATER- RESISTANT GYPSUM BACKING BOARD SHALL BE USED AS A BASE FOR TILE IN WATER CLOSET COMPARTMENT WALLS WHEN INSTALLED IN ACCORDANCE WITH GA -216 OR ASTM C840 REGULAR GYPSUM WALLBOARD IS PERMITTED UNDER TILE OR WALL PANELS IN OTHER WALL AND CEILING AREAS WHEN INSTALLED IN ACCORDANCE WITH GA -216 OR ASTM C840. WATER-RESISTANT GYPSUM BOARD SHALL NOT BE USED IN THE FOLLOWING LOCATIONS: (CBC 2509.2) OVER A VAPOR RETARDER. IN AREAS SUBJECT TO HIGH HUMIDITY, SUCH AS SAUNAS, STEAM ROOMS OR GANG SHOWER ROOMS. DOOR SCHEDULE, FRAME TYPE & WINDOW GENERAL NOTES 1. CONTRACTOR TO FIELD VERIFY ALL SIZES AND TYPES PRIOR TO ORDERING WINDOWS AND DOORS. 2. WINDOW EMERGENCY ESCAPE AND RESCUE OPENING PER R310.1 - WHERE EMERGENCY ESCAPE AND RESCUE OPENINGS ARE PROVIDED THEY SHALL HAVE THE BOTTOM OF THE CLEAR OPENING NOT GREATER THAN 44 INCHES (1118 MM) MEASURED FROM THE FLOOR. WINDOWS MINIMUM NET CLEAR OPENING OF 5.7 FEET, THE MINIMUM NET CLEAR OPENING WIDTH SHALL BE 20 INCHES (508 MM). WINDOW MINIMUM NET CLEAR OPENING HEIGHT SHALL BE 24 INCHES (610 MM). 3. ALL DOORS SHALL BE 1-3/4" THICK UNLESS NOTED OTHERWISE. 4. ALL INTERIOR DOORS SHALL BE UNDERCUT 3/4" A.F.F. UNLESS NOTED OTHERWISE. 5. TEMPERED GLASS IS REQUIRED IN ALL LOCATIONS ESTABLISHED BY THE IBC. THOSE ARE AS FOLLOWS: 1. ALL GLAZING IN DOORS. 2. GLAZING WITHIN 24" OF THE EDGE OF A DOOR AND THE BOTTOM EDGE OF GLASS IS LESS THAN 18" ABOVE THE WALKING SURFACE. 3. ANY GLAZING THAT MEETS ALL FOUR OF THE FOLLOWING CRITERIA: THE BOTTOM EDGE IS LESS THAN 18" ABOVE WALKING SURFACE, AND THE PANE IS GREATER THAN 9 SQUARE FEET, AND THE TOP EDGE IS GREATER THAN 36" ABOVE WALKING SURFACE, AND A WALKING SURFACE IS WITHIN 36" OF THE OPENING. (THE OUTBOARD PANE OF INSULATED GLASS UNITS DOES NOT NEED TO BE TEMPERED IF THE BOTTOM EDGE OF GLASS IS 25' OR MORE ABOVE GRADE.) 4. ALL GLAZING IN GUARDS AND RAILINGS. 5. ANY GLAZING WITHIN 60" OF A STAIRWAY, LANDING, OR RAMP IF THE BOTTOM EDGE IS LESS THAN 60" ABOVE WALKING SURFACE (ONLY IF NO GUARDRAIL IS PROVIDED). 6. ANY GLAZING WITHIN 60" HORIZONTALLY OF THE BOTTOM TREAD OF A STAIRWAY IF THE BOTTOM EDGE IS LESS THAN 60" ABOVE THE NOSE OF THE TREAD (ONLY IF NO GUARDRAIL IS PROVIDED). 7. ALL GLASS SHOWER DOORS. 6. REFER TO THE FLOOR PLANS FOR EXACT LOCATIONS OF DOORS AND DIRECTION OF DOOR SWINGS. 7. VERIFY ALL DIMENSIONS IN FIELD PRIOR TO FABRICATION. 8. DIMENSIONS SHOWN ARE NOMINAL AND/OR ROUGH OPENINGS, CONTRACTOR TO ACCOUNT FOR JOINTS, SHIMS, SEALANT, ETC. 9. SOME FRAME TYPES ARE REPEATED AS SIMILAR OR OPPOSITE. SEE ELEVATIONS OR PLANS FOR QUANTITIES, LOCATIONS AND INSTALLATION. 10. LANDINGS OR FINISH FLOORS AT THE REQUIRED EGRESS DOOR SHALL NOT BE MORE THAN 1-1/2" LOWER THAN THE TOP OF THE THRESHOLD. CRC 311.1 KEYNOTES1#1 1. 3/4 HP GARAGE DOOR OPENER 2. OUTDOOR SHOWER WITH HOT AND COLD WATER AND SANITARY DRAIN. HOT MOP AND TILE PAN. TILE WALLS TO CEILING. 3. MINIMUM 18 PLATFORM BELOW FAU. 4. PROVIDE 2 - 14"X 12" LOUVERED VENTS WITH 1/4" GALVANIZED MESH SCREENING. ONE WITH 12" OF CEILING, ONE 12" ABOVE PLATFORM. 5. KITCHEN CABINETS - UPPERS AND LOWERS. 6. KITCHEN SINK WITH GARBAGE DISPOSAL. 7. CABINET DEPTH REFRIGERATOR WITH UPPERS ABOVE. B. 5/8" TYPE "X" GYP ON ALL WALLS AND CEILING BELOW STAIR 9. SINK CABINET WITH SOLID STONE SURFACE. 10. TALL LINEN CABINET. 13. RATED WALL ASSEMBLY SEE DETAIL 2/A9. 14. RATED WALL ASSEMBLY SEE DETAIL 3/A9. 15. RATED CEILING ASSEMBLY SEE DETAIL 4/A9. 16. DEX-O-TEX WEATHERWEAR ROOF DECK COVERING - ESR -1757 DOOR SCHEDULE MARK WD SIZE HGT THK NOTES 1 T-6" 8'-0" 13/4" T-6" 2 12'-0" 8'-0" 1 1/2" TEMPERED GLASS 3 2'-8" 8'-0" 11/2" 5 4 2'-8" 8'-0" 11/2" T-0" 5 T-0" 8'-0" 1 3/4" SOLID CORE OR 20 MIN.RATED DOOR WITH SELF-CLOSING DEVICE. 6 T-0" 8'-0" 13/4" CASEMENT - 7 16'-0" T-0" 11/2" 10 8 2'-8" 6'-B" 11/2" 6'-0" 9 4'-0" 6'-8" 11/2" 4'-0" 10 10'-0" 6-8" 1 1/2" TEMPERED GLASS 11 2'-8" 6'-8" 11/2" 15 12 2'-8" 6'-8" 11/2" 2'-0" 13 T-0" 6-8" 11/2" 2'-0" 14 2'-8" 6-8" 11/2" CASEMENT 15 T-0" 6'-8" 11/2" 20 16 6'-4" 6-8" 11/4" 3'-0" 17 T-0" 6'-8" 11/2" 5'-0" 18 6'-4" 6'-8" 11/4" FIXED - 19 2'-8" 6'-8" 11/2" * SEE DETAIL 5/A9 FOR WEATHER PROOFING OPENINGS 20 2'-8" 6'-8" 11/2" 21 8'-0" 6-8" 1 1/2" TEMPERED GLASS 22 2'-0" 6'-8" 11/2" 23 2'-8" 6'-8" 11/2" 24 2'-8" 6'-B" 11/2" * SEE DETAIL 5/A9 FOR WEATHER PROOFING OPENINGS WINDOW SCHEDULE <#> MARK SIZE Width HEIGHT TYPE NOTES 1 T-0" 6'-0" CASEMENT - 2 2'-0" T-6" FIXED - 3 T-0" 5'-0" FIXED 4 8'-0" 4'-0" CASEMENT 5 T-10" 3'-10" FIXED - 6 T-0" 5'-0" FIXED 7 T-0" 5'-0" FIXED 8 T-0" 5'-0" CASEMENT - 9 2'-0" 2'-0" CASEMENT - 10 2'-0" 2'-0" CASEMENT - 11 6'-0" 4'-0" CASEMENT 12 6'-0" 4'-0" CASEMENT 13 2'-0" 2'-0" CASEMENT 14 2'-0" 2'-0" CASEMENT 15 4'-0" 1'-6" CASEMENT 16 2'-0" 2'-0" CASEMENT 17 2'-0" 2'-0" CASEMENT 18 8'-0" T-0" CASEMENT 19 3'4" 5'-0" FIXED 20 3'-0" 5-0" FIXED 21 3'-0" 5'-0" FIXED 22 2'-0" 5'-0" FIXED 23 2'-0" 5-0" FIXED - * SEE DETAIL 5/A9 FOR WEATHER PROOFING OPENINGS TOTAL LIGHTING AREA CALCULATION LIVING ROOM, DINNING ROOM AND KITCHEN - 543 / 146 = 0.27 BEDROOM #1 - 237 / 91 = 0.38 BEDROOM #2 - 131 /24=0.18 BEDROOM #3 - 131 / 24 = 0.18 BEDROOM #4 - 194 / 53 = 0.27 OPERABLE VENTILATION AREA CALCULATION LIVING ROOM, DINNING ROOM AND KITCHEN - 543 / 114 = 0.21 BEDROOM #1 - 237 / 70 = 0.30 BEDROOM #2 - 131 /24=0.18 BEDROOM #3 - 131 / 24 = 0.18 BEDROOM #4-194/36=0.19 LEGEND EXISTING WALL mono///�EIATY&TVITAlI _pG _P�_C VALVE - HOT/COLD/GAS -p;p SHB HOSE BIB 3 \ 114'T IRD FLOOR PLAN i l4" = 1'-0" 2735 DE SOTO AVE. COSTA MESA, CA 92626 949.274.6585 JJABDESIGN@GMAIL.COM JASON BLACKMORE PROJECT �4� NEW 3 STORY 4 BEDROOM RESIDENCE 309 CORONADO STREET NEWPORT BEACH, CA 92661 CLIENT SEPULVEDA BUILDERS, INC 790 NEWTON WAY COSTA MESA, CA 92627 CONTENT PREPARED BY JJB PROJECT 180201 DATE 05.29.2018 SHEET A5 ?-4 (N) RIDGE 38'-0" 3RD FLOOR TOP OF WALL 35'-0" I OIL TOP OF RAILING 31'-6" OL (N) 3RD FLOOR 28'-0" I CEILING HEIGHT 27'-0" (N) 2ND FLOOR 19'-0" CEILING HEIGHT 18'-0" METAL ROOFING I LIGHTER OR DARKER — CHANGE IN PAINT CO OR IIV SMOOTH STUCCO FINISH. 2 LAYERS GRADE D BUILDING PAPER BARRIER (N) FINISH FLOOR (1ST FLR) 9'-0" NOTE: HEIGHT CERTIFICATION REQUIRED EAST ELEVATION - STONE OPTION 2 114" = 1._0.. (N) RIDGE 38'-0" 3RD FLOOR TOP OF WALL 35'-0" OIL TOP OF RAILING 31'-6" OL (N) 3RD FLOOR 28'-0" CEILING HEIGHT 27'-0" 0 LTJ OL (N) 2ND FLOOR 19'_0" R CEILING HEIGHT 18'-0" SMOOTH STUCCO 12 A4 (N) FINISH FLOOR (1ST FLR) 9'-0" NOTE: HEIGHT CERTIFICATION REQUIRED 4 WEST ELEVATION va^ = n0^ 1 �2 3 SLOPE 12 73 SLOPE K]Sb (N) RIDGE 38'-0" I 3RD FLOOR TOP OF WALL 35'-0" TOP OF RAILING 31'-6" (N)3RD FLOOR 28'-0" CEILING HEIGHT 27'-0" I OL (N)2ND FLOOR 19'-0" CEILING HEIGHT 18'-0" SMOOTH STUC R LAYERS GRADI PAPER BARRIE (N) FINISH FLOOR (1ST FLR) 9'-0" NOTE: HEIGHT CERTIFICATION REQUIRED l SOUTH ELEVATION � 1 va•� = r-0• (N) RIDGE 38'-0" 3RD FLOOR TOI 35'-0" OL TOP OF RAILIN( 31'-6" OL (N) 3RD FLOOR 28'-0" CEILING HEIGH' 27'-0" I OL (N) 2ND FLOOR FL 19.-0„ CEILING HEIGH 18'-0" OIL (N) FINISH FLOC 9'-0" NOTE: HEIGHT CERTIFICATION REQUIRED 1 NORTH ELEVATION 2735 DE SOTO AVE. COSTA MESA, CA 92626 949.274.6585 JJABDESIGN@GMAIL.COM JASON BLACKMORE PROJECT NEW 3 STORY 4 BEDROOM RESIDENCE 309 CORONADO STREET NEWPORT BEACH, CA 92661 CLIENT SEPULVEDA BUILDERS, INC 790 NEWTON WAY COSTA MESA, CA 92627 CONTENT ELEVATIONS PREPARED BY JJB PROJECT 180201 DATE 05.29.2018 SHEET 7.97' 3 \ BUIING SECTION 114 LD 1119191 7.97' 1 \BUILDING SECTION il4" = 1'-0" BUILDING SECTION 7.2' M- 161 7.2' 2 ) BUILDING SECTION r14191 2735 DE SOTO AVE. COSTA MESA, CA 92626 949.274.6585 JJABDESIGN@GMAIL.COM JASON BLACKMORE i4� PROJECT NEW 3 STORY 4 BEDROOM RESIDENCE 309 CORONADO STREET NEWPORT BEACH, CA 92661 CLIENT SEPULVEDA BUILDERS, INC 790 NEWTON WAY COSTA MESA, CA 92627 CONTENT BUILDING SECTIONS PREPARED BY JJB PROJECT 180201 DATE 05.29.2018 SHEET A7 2 2ND FLOOR BELOW ROOF PLAN v4" = r -o„ ROOF KEYNOTES ONEW METAL ROOF SYSTEM. MANUFACTURER: METAL SALES MANUFACTURING CORPORATION -PRODUCT NAME -VERTICAL SEAM. APPROVAL ESR -2385. GENERAL NOTES 1. VERIFY ROOF SLOPE PRIOR TO CONSTRUCTION. 2. INSULATION HAS 1" MIN. AIR SPACE ABOVE IN VAULTED CEILING. 3. INSTALLATION OF ROOFING SHALL BE IN ACCORDANCE WITH MANUFACTURES SPECIFICATIONS. 4. COMPOSITION SHINGLE ROOF OVER LAPPED 30# A.S. FELT (TYP. THRU OUT) 5. COORDINATE INSTALLATION OF NEW ROOFING WITH OTHER TRADES. REPORT ANY CONFLICTS WITH ITEMS INSTALLED BY OTHER TRADES TO DESIGNER. 6. ALL ROOF CURBS FOR NEW ROOFTOP EXHAUST FANS, HVAC UNITS AND CONDENSING UNITS SHALL HAVE CURB HEIGHTS THAT WILL ALLOW FOR A MINIMUM OF 8" BASE FLASHING HEIGHTS FOR THE ROOF SYSTEM. 7. ALL PLUMBING VENTS SHALL EXTEND ABOVE THE FINISHED SURFACE OF THE ROOF SYSTEM AS REQUIRED TO PROVIDE FOR A MINIMUM OF 8" BASE FLASHING. 8. PROVIDE 36" WIDE WALK PADS @ SERVICE SIDE OF ALL MECH. EQUIPMENT. 9. ALL EXPOSED METAL FLASHING/ TRIM PIECES TO BE PRE -FINISHED 24 GA. STL. U.N.O.. PROVIDE PRE -FINISHED OR FIELD PAINT FLASHING ONLY AS NOTED. 10. R903.4.1 OVERFLOW DRAINS AND SCUPPERS. WHERE ROOF DRAINS ARE REQUIRED, OVERFLOW DRAINS HAVING THE SAME SIZE AS THE ROOF DRAINS SHALL BE INSTALLED WITH THE INLET FLOW LINE LOCATED 2 INCHES (51 MM) ABOVE THE LOW POINT OF THE ROOF, OR OVERFLOW SCUPPERS HAVING THREE TIMES THE SIZE OF THE ROOF DRAINS AND HAVING A MINIMUM OPENING HEIGHT OF 4 INCHES (102 MM) SHALL BE INSTALLED IN THE ADJACENT PARAPET WALLS WITH THE INLET FLOW LOCATED 2 INCHES (51 MM) ABOVE THE LOW POINT OF THE ROOF SERVED. THE INSTALLATION AND SIZING OF OVERFLOW DRAINS, LEADERS AND CONDUCTORS SHALL COMPLY WITH THE CALIFORNIA PLUMBING CODE. 11. PROVIDE ICE BREAKS AT ALL PERIMETER AREAS OF STANDING SEAM ROOFING. 12. PROVIDE 36" WIDE WALK PADS @ SERVICE SIDE OF ALL MECH. EQUIPMENT. & PROVIDE 36" WIDE WALK PADS AROUND ALL ROOF HATCHES & 72"X72" PADS AT LADDERS. 13. ALL EXPOSED METAL FLASHING/ TRIM PIECES TO BE PRE -FINISHED 24 GA. STL. U.N.O.. PROVIDE PRE -FINISHED OR FIELD PAINT FLASHING ONLY AS NOTED. 14. GUTTERS - ALL GUTTERS TO BE PRE -FINISHED 24 GA. STL.. PROVIDE PRE -FINISHED GALV. STL. BENT PLATE BRACKETS AND 14GAX1" GALV. STL. SPACERS @ 36" O.C. MAX. - STAGGER W/ EACH OTHER @ 18" O.C.. PROVIDE PRE -FORMED 15. GUTTER E.J.'S PER SMACNA FIG. 1-7, TYP. @ 30'-0" MAX.. PROVIDE S.S. SCREENS @ ALL GUTTERS PER SMACNA FIG 1-24. 16. ALL DOWNSPOUTS TO BE PRE -FINISHED 24 GA. GALV. STL., PER SMACNA FIG 1-32B. DOWNSPOUTS ARE 6"X6" U.N.O.. LOCATED AS NOTED ON ROOF PLAN. 15GA.X2" GALV. STL. HANGERS @ 48" O.C. MAX. PER SMACNA FIG 1-35B. 17. PROVIDE PAINTED 4' TALL CAST ALUM. DOWNSPOUT BOOTS @ ALL DOWN SPOUTS, TIE INTO SUB -GRADE DRAINAGE, RE: CIVIL. 18. TAPERED INSULATION TO BE 1/4" PER FOOT MIN. SLOPE TO DRAIN. ROOF PLAN SHOWS TAPERED INSULATION FOR GRAPHIC REPRESENTATION ONLY. CONTRACTOR TO VERIFY INSULATION REQUIRED TO SLOPE PRIOR TO MEMBRANE INSULATION. 19. PROVIDE TAPERED INSULATION CRICKETS 1/4" PER FOOT MIN. SLOPE @ HIGH SIDE OF ALL MECHANICAL UNITS AND ROOF HATCHES, TO SHED WATER AROUND AND MAINTAIN POSITIVE ROOF DRAINAGE. 20. ALL WOOD BLOCKING AT ROOF EDGES, RIDGES, ETC. TO BE 2X FR -WD BLOCKING. 21. VERIFY ELEVATION OF ROOF DRAIN RELATIVE TO OVERFLOW SCUPPER PRIOR TO INSTALLATION OF SCUPPERS l i L 9jz!6,Lkko' 2735 DE SOTO AVE. COSTA MESA, CA 92626 949.274.6585 JJABDESIGN@GMAIL.COM JASON BLACKMORE PROJECT NEW 3 STORY 4 BEDROOM RESIDENCE 309 CORONADO STREET NEWPORT BEACH, CA 92661 CLIENT SEPULVEDA BUILDERS, INC 790 NEWTON WAY COSTA MESA, CA 92627 CONTENT aslolu ilml PREPARED BY JJB PROJECT 180201 DATE 05.29.2018 SHEET W N a� O o,� 1 (N) RIDGE DEC L F_ 00 O - ROOF KEYNOTES ONEW METAL ROOF SYSTEM. MANUFACTURER: METAL SALES MANUFACTURING CORPORATION -PRODUCT NAME -VERTICAL SEAM. APPROVAL ESR -2385. GENERAL NOTES 1. VERIFY ROOF SLOPE PRIOR TO CONSTRUCTION. 2. INSULATION HAS 1" MIN. AIR SPACE ABOVE IN VAULTED CEILING. 3. INSTALLATION OF ROOFING SHALL BE IN ACCORDANCE WITH MANUFACTURES SPECIFICATIONS. 4. COMPOSITION SHINGLE ROOF OVER LAPPED 30# A.S. FELT (TYP. THRU OUT) 5. COORDINATE INSTALLATION OF NEW ROOFING WITH OTHER TRADES. REPORT ANY CONFLICTS WITH ITEMS INSTALLED BY OTHER TRADES TO DESIGNER. 6. ALL ROOF CURBS FOR NEW ROOFTOP EXHAUST FANS, HVAC UNITS AND CONDENSING UNITS SHALL HAVE CURB HEIGHTS THAT WILL ALLOW FOR A MINIMUM OF 8" BASE FLASHING HEIGHTS FOR THE ROOF SYSTEM. 7. ALL PLUMBING VENTS SHALL EXTEND ABOVE THE FINISHED SURFACE OF THE ROOF SYSTEM AS REQUIRED TO PROVIDE FOR A MINIMUM OF 8" BASE FLASHING. 8. PROVIDE 36" WIDE WALK PADS @ SERVICE SIDE OF ALL MECH. EQUIPMENT. 9. ALL EXPOSED METAL FLASHING/ TRIM PIECES TO BE PRE -FINISHED 24 GA. STL. U.N.O.. PROVIDE PRE -FINISHED OR FIELD PAINT FLASHING ONLY AS NOTED. 10. R903.4.1 OVERFLOW DRAINS AND SCUPPERS. WHERE ROOF DRAINS ARE REQUIRED, OVERFLOW DRAINS HAVING THE SAME SIZE AS THE ROOF DRAINS SHALL BE INSTALLED WITH THE INLET FLOW LINE LOCATED 2 INCHES (51 MM) ABOVE THE LOW POINT OF THE ROOF, OR OVERFLOW SCUPPERS HAVING THREE TIMES THE SIZE OF THE ROOF DRAINS AND HAVING A MINIMUM OPENING HEIGHT OF 4 INCHES (102 MM) SHALL BE INSTALLED IN THE ADJACENT PARAPET WALLS WITH THE INLET FLOW LOCATED 2 INCHES (51 MM) ABOVE THE LOW POINT OF THE ROOF SERVED. THE INSTALLATION AND SIZING OF OVERFLOW DRAINS, LEADERS AND CONDUCTORS SHALL COMPLY WITH THE CALIFORNIA PLUMBING CODE. 11. PROVIDE ICE BREAKS AT ALL PERIMETER AREAS OF STANDING SEAM ROOFING. 12. PROVIDE 36" WIDE WALK PADS @ SERVICE SIDE OF ALL MECH. EQUIPMENT. & PROVIDE 36" WIDE WALK PADS AROUND ALL ROOF HATCHES & 72"X72" PADS AT LADDERS. 13. ALL EXPOSED METAL FLASHING/ TRIM PIECES TO BE PRE -FINISHED 24 GA. STL. U.N.O.. PROVIDE PRE -FINISHED OR FIELD PAINT FLASHING ONLY AS NOTED. 14. GUTTERS - ALL GUTTERS TO BE PRE -FINISHED 24 GA. STL.. PROVIDE PRE -FINISHED GALV. STL. BENT PLATE BRACKETS AND 14GAX1" GALV. STL. SPACERS @ 36" O.C. MAX. - STAGGER W/ EACH OTHER @ 18" O.C.. PROVIDE PRE -FORMED 15. GUTTER E.J.'S PER SMACNA FIG. 1-7, TYP. @ 30'-0" MAX.. PROVIDE S.S. SCREENS @ ALL GUTTERS PER SMACNA FIG 1-24. 16. ALL DOWNSPOUTS TO BE PRE -FINISHED 24 GA. GALV. STL., PER SMACNA FIG 1-32B. DOWNSPOUTS ARE 6"X6" U.N.O.. LOCATED AS NOTED ON ROOF PLAN. 15GA.X2" GALV. STL. HANGERS @ 48" O.C. MAX. PER SMACNA FIG 1-35B. 17. PROVIDE PAINTED 4' TALL CAST ALUM. DOWNSPOUT BOOTS @ ALL DOWN SPOUTS, TIE INTO SUB -GRADE DRAINAGE, RE: CIVIL. 18. TAPERED INSULATION TO BE 1/4" PER FOOT MIN. SLOPE TO DRAIN. ROOF PLAN SHOWS TAPERED INSULATION FOR GRAPHIC REPRESENTATION ONLY. CONTRACTOR TO VERIFY INSULATION REQUIRED TO SLOPE PRIOR TO MEMBRANE INSULATION. 19. PROVIDE TAPERED INSULATION CRICKETS 1/4" PER FOOT MIN. SLOPE @ HIGH SIDE OF ALL MECHANICAL UNITS AND ROOF HATCHES, TO SHED WATER AROUND AND MAINTAIN POSITIVE ROOF DRAINAGE. 20. ALL WOOD BLOCKING AT ROOF EDGES, RIDGES, ETC. TO BE 2X FR -WD BLOCKING. 21. VERIFY ELEVATION OF ROOF DRAIN RELATIVE TO OVERFLOW SCUPPER PRIOR TO INSTALLATION OF SCUPPERS l i L 9jz!6,Lkko' 2735 DE SOTO AVE. COSTA MESA, CA 92626 949.274.6585 JJABDESIGN@GMAIL.COM JASON BLACKMORE PROJECT NEW 3 STORY 4 BEDROOM RESIDENCE 309 CORONADO STREET NEWPORT BEACH, CA 92661 CLIENT SEPULVEDA BUILDERS, INC 790 NEWTON WAY COSTA MESA, CA 92627 CONTENT aslolu ilml PREPARED BY JJB PROJECT 180201 DATE 05.29.2018 SHEET