Loading...
HomeMy WebLinkAbout06_Fanticola Residence Coastal Development Permit_PA2018-16103/13/2018 CITY OF NEWPORT BEACH ZONING ADMINISTRATOR STAFF REPORT October 25, 2018 Agenda Item No. 6 SUBJECT: Fanticola Residence (PA2018-161) Coastal Development Permit No. CD2018-069 SITE LOCATION: 1120 West Ocean Front APPLICANT: Brandon Architects OWNER: Tony and Joann Fanticola PLANNER: Benjamin M. Zdeba, AICP, Associate Planner 949-644-3253, bzdeba@newportbeachca.gov LAND USE AND ZONING General Plan: Single-Unit Residential Detached (RS-D) Zoning District: Single-Unit Residential (R-1) Coastal Land Use Category: Single-Unit Residential Detached (10.0 – 19.9 DU/AC) (RSD-C) Coastal Zoning District: Single-Unit Residential (R-1) PROJECT SUMMARY A request for a coastal development permit for the demolition of an existing single -family residence and the construction of a new, ap proximately 4,523-square-foot, three-story single-family residence with a 624-square-foot, three-car garage. The development also includes site walls and other accessory structures, hardscape, drainage, and landscaping. The proposed development complies with all applicable development standards including height, setbacks, and floor area limits. No deviations are requested. All proposed improvements are within the confines of private property and are shown on the attached plans (Attachment No. ZA 3). RECOMMENDATION 1)Conduct a public hearing; 2)Find this project exempt from the California Environmental Quality Act (CEQA) pursuant to Section 15303 under Class 3 (New Construction or Conversion of Small Structures); and 3)Adopt Draft Zoning Administrator Resolution No. _ approving Coastal Development Permit No. CD2018-069 (Attachment No. ZA 1). 1 Zoning Administrator, October 25, 2018 Page 2 Tmplt: 04/03/18 DISCUSSION Land Use and Development Standards  The subject property is located in the R-1 Coastal Zoning District, which provides for single-unit residential development and is consistent with the City’s Coastal Land Use Plan, General Plan, and Zoning Code. A coastal development permit is required and the property is not eligible for a waiver for de minimis development because the property is located in the Coastal Commission Appeal Area.  The property currently consists of one legal lot developed with a single-family residence. The neighborhood is predominantly developed with two- and three- story, single- and two-unit residences.  The proposed residence and accessory structures conform to all applicable development standards, including floor area limit, setbacks, height, and off-street parking as evidenced by the project plans and illustrated in Table 1 below. Table 1 – Development Standards Development Standard Standard Proposed Setbacks (min.) Front 9 feet 14 feet (first floor) 6 feet (second floor balcony)(2) Sides 3 feet 3 feet Rear (1) 0 feet 7 feet, 7 inches (first floor) 4 feet, 7 inches (second floor) Allowable Floor Area (max.) 5,686.26 square feet 5,147 square feet Allowable 3rd Floor Area (max.) 426.47 square feet 400 square feet Open Space (min.) 426.47 square feet 567 square feet Parking (min.) 3-car garage 3-car garage Height (max.) 24 feet flat roof 29 feet sloped roof 24 feet flat roof 29 feet sloped roof (1) Zero rear setback required adjacent to future 20-foot-wide alley. (2) Balconies abutting West Ocean Front may encroach up to a maximum of 36 inches into the required front setback per NBMC Subsection 21.30.110(D)(5).  The proposed three-story design and partially covered roof deck results in bulk and scale of the development that is consistent with the existing neighborhood pattern of development and expected future development consistent with applicable development standards. Hazards  The subject property fronts the Pacific Ocean, but is separated from the shoreline by a very wide sandy beach (approximately 575-foot separation). The project site is not protected by a bulkhead. 2 Zoning Administrator, October 25, 2018 Page 3 Tmplt: 04/03/18  The finish floor elevation of the proposed dwelling is 12.40 feet based on the North American Vertical Datum of 1988 (NAVD88), which exceeds the minimum 9.0-foot (NAVD88) elevation standard for new structures. A Coastal Hazard Report and Wave Runup Study prepared by GeoSoils, Inc., dated July 11, 2018, indicates a likely sea level rise projection of between 1.8 and 4.6 feet over the next 75 years resulting in a future water elevation of between 9.3 feet and 12.1 feet (NAVD88). The report concludes it is very unlikely that any type of wave will reach the site even considering a 4.6-foot sea level rise and that the proposed project is reasonably safe from the shoreline erosion due to lack of wave or wakes that can erode sand from the beach. Overall, the analysis concludes that the proposed project will be safe from flooding hazards for the next 75 years. Furthermore, the report concluded that due to the distance of the property from the curre nt mean high tide line (approximately 575 feet) that it is unlikely that the mean high tide line will reach the property within the next 75 years.  Pursuant to NBMC Section 21.30.030(C)(3)(i)(iv), the property owner will be required to enter into an agreement with the City waiving any potential right to protection to address situations in the future in which the development is threatened with damage or destruction by coastal hazards (e.g., waves, erosion, and sea level rise). The property owner will also be required to acknowledge any hazards present at the site and unconditionally waive any claim to damage or liability against the decision authority, consistent with NBMC Section 21.30.015(D)(3)(c). Both requirements are included as conditions of approval that will need to be satisfied prior to the issuance of building permits for construction.  The property is located in an area known for the potential of seismic activity and liquefaction. All projects are required to comply with the California Building Code (CBC) and Building Division standards and policies. Geotechnical investigations specifically addressing liquefaction are required to be reviewed and approved prior to the issuance of a building permit. Permit issuance is also contingent on the inclusion of design mitigation identified in the investigations. Construction plans are reviewed for compliance with approved investigations and CBC prior to building permit issuance. Water Quality  The development is set back approximately 575 feet from coastal waters. Due to the large distance, a Water Quality Management Plan is not required. A post- construction drainage system will be installed that includes drainage and percolation features designed to retain dry weather and minor rain run-off on-site to ensure the project does not impact water quality. Any water not retained on-site is directed to the City’s storm drain system.  The project design addresses water quality with a construction erosion control plan that outlines temporary Best Management Practices (BMPs) to be implemented 3 Zoning Administrator, October 25, 2018 Page 4 Tmplt: 04/03/18 during construction to minimize erosion and sedimentation, and to minimize pollution of runoff derived by construction chemicals and materials. No water quality impacts to coastal waters are anticipated based upon the location and elevation of the property. Public Access  The project site is located between the nearest public road and the sea or shoreline; however, the project will not affect the public’s ability to gain access to, use, and/or view the coast and nearby recreational facilities. Vertical access to the bay front and beach front is available approximately 180 feet east of the site at the intersection of West Ocean Front and 11th Street, and also 180 feet to the west of the site at the intersection of West Ocean Front and 12th Street.  Lateral access and views of the ocean are also available along an existing 6-foot- wide public boardwalk in front of the project site.  The project site is located adjacent to the public beach and the public Ocean Front boardwalk. Due to the project location, an initial evaluation of the potential impact to the view shed or the scenic and visual qualities of the coastal zone was conducted pursuant to NBMC Section 21.30.100 (Scenic and Visual Quality Protection). Expansive views of the Newport Pier, Balboa Pier, Pacific Ocean, and public beach are afforded from the public sidewalk along West Ocean Front. However, the subject property is located landward of the public vantage points and not between public vantage points and these view features. Therefore, the project will not impact existing, nor provide an opportunity to enhance, public views along these vantage points.  The project will replace an existing single-unit residence with a new single-unit residence that complies with all applicable Local Coastal Program (LCP) development standards and maintains a building envelope consistent with the existing and anticipated future neighborhood pattern of development. Therefore, the project does not have the potential to degrade the visual quality of the Coastal Zone. ENVIRONMENTAL REVIEW This project is exempt from the California Environmental Quality Act (CEQA) pursuant to Section 15303 under Class 3 (New Construction or Conversion of Small Structures) of the CEQA Guidelines, California Code of Regulations, Title 14, Chapter 3, because it has no potential to have a significant effect on the environment. Class 3 exempts the demolition of up to three single-family residences and additions of up to 10,000 square feet to existing structures. The proposed project consists of the demolition of one single-family residence and the construction of a new 4,523-square-foot single-family residence and 624-square-foot two-car garage in the R-1 District. 4 Zoning Administrator, October 25, 2018 Page 5 Tmplt: 04/03/18 The exceptions to this categorical exemption under Section 15300.2 are not applicable. The project location does not impact an environmental resource of hazardous or critical concern, does not result in cumulative impacts, does not have a significant effect on the environment due to unusual circumstances, does not damage scenic resources within a state scenic highway, is not a hazardous waste site, and is not identified as a historical resource. PUBLIC NOTICE Notice of this public hearing was published in the Daily Pilot, mailed to all owners and residential occupants of property within 300 feet of the boundaries of the site (excluding intervening rights-of-way and waterways), including the applicant, and posted on the subject property at least 10 days before the scheduled hearing, consistent with the provisions of the Municipal Code. Additionally, the item appeared on the agenda for this meeting, which was posted at City Hall and on the City website. APPEAL PERIOD This action shall become final and effective 14 days following the date the Resolution is adopted unless within such time an appeal or call for review is filed with the Community Development Director in accordance with the provisions of Title 21 (Local Coastal Implementation Plan) of the Newport Beach Municipal Code. Final action taken by the City may be appealed to the Coastal Commission in compliance with Section 21.64.035 of the City’s certified LCP and Title 14 California Code of Regulations, Sections 13111 through 13120, and Section 30603 of the Coastal Act. For additional information on filing an appeal, contact the Planning Division at 949-644-3200. Prepared by: _____________________ Benjamin M. Zdeba, AICP Associate Planner GBR/bmz Attachments: ZA 1 Draft Resolution ZA 2 Vicinity Map ZA 3 Project Plans 5 03/13/2018 Attachment No. ZA 1 Draft Resolution 6 05-15-2018 RESOLUTION NO. ZA2018-### A RESOLUTION OF THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH, CALIFORNIA, APPROVING COASTAL DEVELOPMENT PERMIT NO. CD2018-069 TO DEMOLISH AN EXISTING SINGLE-FAMILY RESIDENCE AND CONSTRUCT A NEW THREE-STORY SINGLE-FAMILY RESIDENCE AND ATTACHED 3-CAR GARAGE LOCATED AT 1120 WEST OCEAN FRONT (PA2018-161) THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH HEREBY FINDS AS FOLLOWS: SECTION 1. STATEMENT OF FACTS. 1. An application was filed by Brandon Architects, with respect to property located at 1120 West Ocean Front, requesting approval of a coastal development permit. 2. The lot at 1120 West Ocean Front is legally described as Lot 6, Block 11, Tract No. 234. 3. The applicant proposes the demolition of an existing two-story single-family residence and construction of a new approximately 4,523-square-foot, three-story single-family residence with a 624-square-foot three-car garage. Also included are site walls and other accessory structures, hardscape, drainage, and landscaping. 4. The subject property is designated Single-Unit Residential Detached (RS-D) by the General Plan Land Use Element and is located within the Single-Unit Residential (R-1) Zoning District. 5. The subject property is located within the coastal zone. The Coastal Land Use Plan category is Single-Unit Residential Detached (10.0 - 19.9 DU/AC) (RSD-C) and the property is located within the Single-Unit Residential (R-1) Coastal Zone District. 6. A public hearing was held on October 25, 2018, in the Corona del Mar Conference Room (Bay E-1st Floor) at 100 Civic Center Drive, Newport Beach. A notice of time, place and purpose of the hearing was given in accordance with the Newport Beach Municipal Code. Evidence, both written and oral, was presented to, and considered by, the Zoning Administrator at this hearing. SECTION 2. CALIFORNIA ENVIRONMENTAL QUALITY ACT DETERMINATION. 1. This project is categorically exempt pursuant to Title 14 of the California Code of Regulations Section 15303 , Article 19 of Chapter 3, Guidelines for Implementation of the California Environmental Quality Act (CEQA) under Class 3 (New Construction or Conversion of Small Structures), because it has no potential to have a significant effect on the environment. 2. Class 3 exempts the demolition of up to three single-family residences and additions of up to 10,000 square feet to existing structures. The proposed project consists of the 7 Zoning Administrator Resolution No. ZA2018-### Page 2 of 9 05-15-2018 demolition of one single-family residence and the construction of a new 4,523-square- foot single-family residence and 624-square-foot two-car garage in the R-1 District. 3. The exceptions to this categorical exemption under Section 15300.2 are not applicable. The project location does not impact an environmental resource of hazardous or critical concern, does not result in cumulative impacts, does not have a significant effect on the environment due to unusual circumstances, does not damage scenic resources within a state scenic highway, is not a hazardous waste site, and is not identified as a historical resource. SECTION 3. REQUIRED FINDINGS. In accordance with Newport Beach Municipal Code (“NBMC”) Section 21.52.015 (Coastal Development Permits, Findings and Decision), the following findings and facts in support of such findings are set forth: Finding: A. Conforms to all applicable sections of the certified Local Coastal Program. Facts in Support of Finding: 1. The proposed development complies with applicable residential development standards including, but not limited to, floor area limitation, setbacks, height, and parking. a. The maximum floor area limitation is 5,686.26 square feet and the proposed floor area is 5,147 square feet. b. The proposed development provides the minimum required setbacks, which are 9 feet along the front property line abutting West Ocean Front, 3 feet along each side property line and 0 feet along the rear property line. c. The highest guardrail is less than 24 feet from established grade (11.81 feet NAVD88) and the highest ridge is no more than 29 feet from established grade, which comply with the maximum height requirements. d. The project includes garage parking for a total of three vehicles, complying with the minimum three-car garage parking requirement for single-family residences with 4,000 square feet or more of habitable floor area. 2. The property currently consists of one legal lot developed with a single-family residence. The neighborhood is predominantly developed with two- and three-story, single-unit and two-unit residences. 3. The proposed three-story design and partially covered roof deck results in bulk and scale of the development that is consistent with the existing neighborhood pattern of development and expected future development consistent with applicable development standards. 8 Zoning Administrator Resolution No. ZA2018-### Page 3 of 9 05-15-2018 4. The subject property fronts the Pacific Ocean, but is separated from the shoreline by a very wide sandy beach (approximately 575-foot separation). The project site is not protected by a bulkhead. 5. The finish floor elevation of the proposed dwelling is 12.40 feet based on the North American Vertical Datum of 1988 (NAVD88), which exceeds the minimum 9.0-foot (NAVD88) elevation standard for new structures. A Coastal Hazard Report and Wave Runup Study prepared by GeoSoils, Inc., dated July 11, 2018, indicates a likely sea level rise projection of between 1.8 and 4.6 feet over the next 75 years resulting in a future water elevation of between 9.3 feet and 12.1 feet (NAVD88). The report concludes it is very unlikely that any type of wave will reach the site even consider ing a 4.6-foot sea level rise and that the proposed project is reasonably safe from the shoreline erosion due to lack of wave or wakes that can erode sand from the beach. Overall, the analysis concludes that the proposed project will be safe from flooding hazards for the next 75 years. Furthermore, the report concluded that due to the distance of the property from the current mean high tide line (approximately 575 feet) that it is unlikely that the mean high tide line will reach the property within the next 75 years. 6. Pursuant to NBMC Section 21.30.030(C)(3)(i)(iv), the property owner will be required to enter into an agreement with the City waiving any potential right to protection to address situations in the future in which the development is threatened with damage or destruction by coastal hazards (e.g., waves, erosion, and sea level rise). The property owner will also be required to acknowledge any hazards present at the site and unconditionally waive any claim to damage or liability against the decision authority, consistent with NBMC Section 21.30.015(D)(3)(c). Both requirements are included as conditions of approval that will need to be satisfied prior to the issuance of building permits for construction. 7. The property is located in an area known for the potential of seismic activity and liquefaction. All projects are required to comply with the California Building Code (CBC) and Building Division standards and policies. Geotechnical investigations specifically addressing liquefaction are required to be reviewed and approved prior to the issuance of building permits. Permit issuance is also contingent on the inclusion of design mitigation identified in the investigations. Construction plans are reviewed for compliance with approved investigations and CBC prior to building permit issuance. 8. The development is set back approximately 575 feet from coastal waters. Due to the large distance, a Water Quality Management Plan is not required. A post-construction drainage system will be installed that includes drainage and percolation features designed to retain dry weather and minor rain run-off on-site to ensure the project does not impact water quality. Any water not retained on-site is directed to the City’s storm drain system. 9. The project design addresses water quality with a construction erosion control plan that outlines temporary Best Management Practices (BMPs) to be implemented during construction to minimize erosion and sedimentation, and to minimize pollution of runoff derived by construction chemicals and materials. No water quality impacts to coastal waters are anticipated based upon the location and elevation of the property. 9 Zoning Administrator Resolution No. ZA2018-### Page 4 of 9 05-15-2018 10. All proposed landscaping will comply with NBMC Section 21.30.075 (Landscaping). A condition of approval is included that requires drought-tolerant species. Prior to issuance of building permits, the final landscape plans will be reviewed to verify invasive species are not planted Finding: B. Conforms with the public access and public recreation policies of Chapter 3 of the Coastal Act if the project is located between the nearest public road and the sea or shoreline of any body of water located within the coastal zone . Fact in Support of Finding: 1. The project site is located between the nearest public road and the sea or shoreline; however, the project will not affect the public’s ability to gain access to, use, and/or view the coast and nearby recreational facilities. Vertical access to the bay front and beach front is available approximately 180 feet east of the site at the intersection of West Ocean Front and 11th Street, and also 180 feet to the west of the site at the intersection of West Ocean Front and 12th Street. 2. Lateral access and views of the ocean are also available along an existing 6-foot-wide public boardwalk in front of the project site. 3. The project site is located adjacent to the public beach and the public sidewalk Ocean Front walkway. Due to the project location, an initial evaluation of the potential impact to the view shed or the scenic and visual qualities of the coastal zone was conducted pursuant to NBMC Section 21.30.100 (Scenic and Visual Quality Protection). Expansive views of the Newport Pier, Balboa Pier, Pacific Ocean, and public beach are afforded from the public boardwalk along West Ocean Front. However, the subject property is located landward of the public vantage points and not between public vantage points and these view features. Therefore, the project will not impact existing, nor provide an opportunity to enhance, public views along these vantage points. 4. The project will replace an existing single-unit residence with a new single-unit residence that complies with all applicable Local Coastal Program (LCP) development standards and maintains a building envelope consistent with the existing and anticipated future neighborhood pattern of development. Therefore, the project does not have the potential to degrade the visual quality of the Coastal Zone. SECTION 4. DECISION. NOW, THEREFORE, BE IT RESOLVED: 1. The Zoning Administrator of the City of Newport Beach hereby approves Coastal Development Permit No. CD2018-069, subject to the conditions set forth in Exhibit “A,” which is attached hereto and incorporated by reference. 10 Zoning Administrator Resolution No. ZA2018-### Page 5 of 9 05-15-2018 2. This action shall become final and effective 14 days following the date this Resolution was adopted unless within such time an appeal or call for review is filed with the Community Development Director in accordance with the provisions of NBMC Title 21 Local Coastal Implementation Plan. Final action taken by the City may be appealed to the Coastal Commission in compliance with Section 21.64.035 of the City’s certified LCP and Title 14 California Code of Regulations, Sections 13111 through 13120, and Section 30603 of the Coastal Act. PASSED, APPROVED, AND ADOPTED THIS 25TH DAY OF OCTOBER, 2018. _____________________________________ Patrick J. Alford, Zoning Administrator 11 Zoning Administrator Resolution No. ZA2018-### Page 6 of 9 05-15-2018 EXHIBIT “A” CONDITIONS OF APPROVAL 1. The development shall be in substantial conformance with the approved site plan, floor plans and building elevations stamped and dated with the date of this approval (except as modified by applicable conditions of approval). 2. Prior to the issuance of a building permit, an agreement in a form approved by the City Attorney between the property owner and the City shall be executed and recorded waiving rights to the construction of future shoreline protection devices to address the threat of damage or destruction from waves, erosion, storm conditions, landslides, seismic activity, bluff retreat, sea level rise, or other natural hazards that may affect the property, or development of the property, today or in the future. The agreement shall be binding against the property owners and successors and assigns. 3. Prior to the issuance of a building permit, the property owner shall submit a notarized signed letter acknowledging all hazards present at the site, assuming the risk of injury or damage from such hazards, unconditionally waiving any claims of dam age against the City from such hazards, and to indemnify and hold harmless City, its City Council, its boards and commissions, officials, officers, employees, and agents from and against any and all claims, demands, obligations, damages, actions, causes of action, suits, losses, judgments, fines, penalties, liabilities, costs and expenses (including without limitation, attorney’s fees, disbursements and court costs) of every kind and nature whatsoever which may arise from or in any manner relate (directly or indirectly) to City’s approval of development. 4. No demolition or construction materials, equipment debris, or waste, shall be placed or stored in a location that would enter sensitive habitat, receiving waters, or a storm drain or result in impacts to environmentally sensitive habitat areas, streams, the beach, wetlands or their buffers. 5. This approval does not authorize any new or existing improvements (including landscaping) on State tidelands, public beaches, or the public right -of-way. 6. This Coastal Development Permit does not authorize any development seaward of the private property. 7. Best Management Practices (BMP’s) and Good Housekeeping Practices (GHP’s) shall be implemented prior to and throughout the duration of construction activity as designated in the Construction Pollution Prevention Plan (CPPP). 8. The discharge of any hazardous materials into storm sewer systems or receiving waters shall be prohibited. Machinery and equipment shall be maintained and washed in confined areas specifically designed to control runoff. A designated fueling and vehicle maintenance area with appropriate berms and protection to prevent spillage shall be provided as far away from storm drain systems or receiving waters as possible. 12 Zoning Administrator Resolution No. ZA2018-### Page 7 of 9 05-15-2018 9. Debris from demolition shall be removed from work areas each day and removed from the project site within 24 hours of the completion of the project. Stock piles and construction materials shall be covered, enclosed on all sites, not stored in contact with the soil, and located as far away as possible from drain inlets and any waterway. 10. Trash and debris shall be disposed in proper trash and recycling receptacles at the end of each construction day. Solid waste, including excess concrete, shall be disposed in adequate disposal facilities at a legal disposal site or recycled at a recycling facility. 11. Revisions to the approved plans may require an amendment to this Coastal Development Permit or the processing of a new coastal development permit. 12. The project is subject to all applicable City ordinances, policies, and standards, unless specifically waived or modified by the conditions of approval. 13. The applicant shall comply with all federal, state, and local laws. Material violation of any of those laws in connection with the use may be cause for revocation of this Coastal Development Permit. 14. This Coastal Development Permit may be modified or revoked by the Zoning Administrator if determined that the proposed uses or conditions under which it is being operated or maintained is detrimental to the public health, welfare or materially injurious to property or improvements in the vicinity or if the property is operated or maintained so as to constitute a public nuisance. 15. Prior to the issuance of building permits, the applicant shall submit a final construction erosion control plan. The plan shall be subject to the review and approval by the Building Division. 16. Prior to the issuance of building permits, the applicant shall submit a final drainage and grading plan. The plan shall be subject to the review and approval by the Building Division. 17. Prior to issuance of a building permit, a copy of the Resolution, including conditions of approval Exhibit “A” shall be incorporated into the Building Division and field sets of plans. 18. Prior to issuance of a building permit, the applicant shall submit to the Planning Division an additional copy of the approved architectural plans for inclusion in the Coastal Development file. The plans shall be identical to those approved by all City departments for building permit issuance. The approved copy shall include architectural sheets only and shall be reduced in size to 11 inches by 17 inches. The plans shall accurately depict the elements approved by this Coastal Development Permit. 19. Prior to the issuance of building permits, the applicant shall submit a final landscape and irrigation plan. These plans shall incorporate drought tolerant plantings, non -invasive plant species and water efficient irrigation design. The plans shall be approved by the Planning Division. 13 Zoning Administrator Resolution No. ZA2018-### Page 8 of 9 05-15-2018 20. All landscape materials and irrigation systems shall be maintained in accordance with the approved landscape plan. All landscaped areas shall be maintained in a healthy and growing condition and shall receive regular pruning, fertilizing, mowing, an d trimming. All landscaped areas shall be kept free of weeds and debris. All irrigation systems shall be kept operable, including adjustments, replacements, repairs, and cleaning as part of regular maintenance. 21. Prior to the issuance of building permit, the applicant shall pay any unpaid administrative costs associated with the processing of this application to the Planning Division. 22. Should the property be sold or otherwise come under different ownership, any future owners or assignees shall be notified of the conditions of this approval by the current property owner or agent. 23. The applicant is responsible for compliance with the Migratory Bird Treaty Act. In compliance with the (MBTA), grading, brush removal, building demolition, tree trimming, and similar construction activities shall occur between August 16 and January 31, outside of the peak nesting period. If such activities must occur inside the peak nesting season from February 1 to August 15, compliance with the following is required to prevent the taking of Native Birds pursuant to MBTA: A. The construction area shall be inspected for active nests. If birds are observed flying from a nest or sitting on a nest, it can be assumed that the nest is active. Construction activity within 300 feet of an active nest shall be delayed until the nest is no longer active. Continue to observe the nest until the chicks have left the nest and activity is no longer observed. When the nest is no longer active, construction activity can continue in the nest area. B. It is a violation of state and federal law to kill or harm a native bird. To ensure compliance, consider hiring a biologist to assist with the survey for nesting birds, and to determine when it is safe to commence construction activities. If an active nest is found, one or two short follow-up surveys will be necessary to check on the nest and determine when the nest is no longer active. 24. This Coastal Development Permit No. CD2018-069 shall expire unless exercised within 24 months from the date of approval as specified in Section 21.54.060 (Time Limits and Extensions) of the Newport Beach Municipal Code, unless an extension is otherwise granted. 25. To the fullest extent permitted by law, applicant shall indemnify, defend and hold harmless City, its City Council, its boards and commissions, officials, officers, employees, and agents from and against any and all claims, demands, obligations, damages, actions, causes of action, suits, losses, judgments, fines, penalties, liabilities, costs and expenses (including without limitation, attorney’s fees, disbursements and court costs) of every kind and nature whatsoever which may arise from or in any manner relate (directly or indirectly) to City’s approval of the Fanticola Residence including, but not limited to, Coastal Development Permit No. CD2018-069 (PA2018-161). This indemnification shall include, but not be limited to, damages awarded against the City, if any, costs of suit, attorneys' fees, and 14 Zoning Administrator Resolution No. ZA2018-### Page 9 of 9 05-15-2018 other expenses incurred in connection with such claim, action, causes of action, suit or proceeding whether incurred by applicant, City, and/or the parties initiating or bringing such proceeding. The applicant shall indemnify the City for all of City's costs, attorneys' fees, and damages, which City incurs in enforcing the indemnification provisions set forth in this condition. The applicant shall pay to the City upon demand any amount owed to the City pursuant to the indemnification requirements prescribed in this condition. 15 03/13/2018 Attachment No. ZA 2 Vicinity Map 16 Feet Every reasonable effort has been made to assure the accuracy of the data provided, however, The City of Newport Beach and its employees and agents disclaim any and all responsibility from or relating to any results obtained in its use. Disclaimer: 10/16/2018 0 200100 PA2018-161 Fanticola Residence Project Site 17 03/13/2018 Attachment No. ZA 3 Project Plans 18 Name Elevation A101 1 SIM Room name 150 SF 101 1i ? 90 00' 00" Distance N E 1 1 A101 SIM R @ 7 1/2"20 1i NORTH ARROW PROPERTY LINE TAG SECTION INDICATOR ROOM TAG (NAME / AREA) CALL-OUT TAG ELEVATION INDICATOR KEYNOTE TAG WINDOW TAG DOOR TAG WALL TAG REVISION FLAG STAIR TAG (NO. OF RISER & HEIGHT) ALUMINUM CONCRETE EARTH GYPSUM - PLASTER INSULATION - RIGID MASONRY - BRICK/STONE MASONRY - CONCRETE BLOCK PLYWOOD / GLU-LAM TIMBER SAND STEEL WOOD JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONSOWNER INFORMATION:PROJECT NAME STATUS These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT T-1.0 06/22/18 1120-2018TITLE SHEETFANTICOLA RESIDENCE FANTICOLARESIDENCEANTONY & JOANNFANTICOLA1120 W. OCEAN FRONTNEWPORT BEACH, CA92661CDP 1120 W. OCEANFRONTNEWPORT BEACH, CA 92661CAITLIN SMITH JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONSOWNER INFORMATION:PROJECT NAME STATUS These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT T-1.0 06/22/18 1120-2018TITLE SHEETFANTICOLA RESIDENCE FANTICOLARESIDENCEANTONY & JOANNFANTICOLA1120 W. OCEAN FRONTNEWPORT BEACH, CA92661CDP 1120 W. OCEANFRONTNEWPORT BEACH, CA 92661CAITLIN SMITH REF. 8/T-1.0FLOOR AREA HEIGHT NBMC (NEWPORT BEACH MUNICIPAL CODE) CALIFORNIA CODES: 2016 CBC, 2016 CFC, 2016 CEC, 2016 CPC, AND 2016 CMC, 2016 CAL GREEN R-3 / U 1-HR. CODES: OCCUPANCY CLASSIFICATION OCCUPANCY SEPARATIONS (GARAGE) OCCUPANT LOAD TYPE OF CONSTRUCTION OWNER: ARCHITECT: N/AALLOWABLE BLDG. AREA (PER CBC TBL. 503) FLOOR & FLOOR-CEILINGS N/A BRANDON ARCHITECTS, INC. 151 KALMUS DR. STE. G-1 COSTA MESA, CA 92626 P: 714.754.4040 WWW.BRANDONARCHITECTS.COM STRUCTURAL ENGINEER:CIVIL ENGINEER: GENERAL CONTRACTOR:LANDSCAPE DESIGNER: SURVEYOR:SOILS ENGINEER: SITE 1 UNIT V-B - SPRK'R. 3 STORY FIRE SPRINKLER: NFPA 13D YES DEFERRED SUBMITTALS 8PROJECT STATISTICS 5 3 1 249 10 AGENCIES & PUBLIC SERVICES VICINITY MAP/ PROJECT DESCRIPTION MATERIAL LEGEND ANNOTATION LEGEND CODE REVIEW SHEET LISTSITE INFORMATION11 7 6SPECIAL INSPECTIONS PROJECT DIRECTORYPROJECT DIRECTORY PROJECT DESCRIPTION: FANTICOLA RESIDENCE BRANDON ARCHITECTS, INC.ANTHONY & JOANN FANTICOLA 1120 W. OCEANFRONT NEWPORT BEACH, CA 92661 P.949.232.5210 TBD TBD BUILDING AREA SCHEDULE NAME AREA COMMENTS FIRST FLOOR 1728 SF SECOND FLOOR 2394 SF THIRD FLOOR 400 SF 4523 SF 3-CAR GARAGE 647 SF 647 SF GRAND TOTAL 5169 SF OUTDOOR AREA SCHEDULE NAME AREA COMMENTS DECK 2 648 SF DECK 1 1111 SF MA. BALCONY 153 SF OPEN SPACE PORCH 151 SF OPEN SPACE ENTRY 40 SF OPEN SPACE OPEN #1 226 SF OPEN SPACE GRAND TOTAL 2329 SF RDM GEOFIRM ZI WANG, LIC. NO. 80199 801 GLENNEYRE ST., STE. F LAUGNA BEACH, CA 92651 P.949.494.2122 F.949.497.0270 FORKETT ENGINEERING, INC. TOM RUIZ P: 714.963.6793 22311 BROOKHURST ST. HUNTINGTON BEACH, CA 92626 SHEET #DRAWING TITLE T-1.0 TITLE SHEET T-1.1 GENERAL ARCHITECTURAL NOTES T-1.2 SUPPLEMENTAL NOTES & DOCUMENTS SUR TOPOGRAPHIC SURVEY A-0.0 ARCHITECTURAL SITE PLAN C2 PRECISE GRADING PLAN C3 SECTIONS A-0.3 GRADE PLANE EXHIBIT A-1.0 3-DIMENSIONAL VIEWS A-2.0 FLOOR PLAN A-2.1 FLOOR PLAN A-3.0 ROOF PLAN A-4.0 EXTERIOR ELEVATIONS & MATERIAL SCHEDULE A-4.1 EXTERIOR ELEVATIONS A-5.0 BUILDING SECTIONS S1 FOUNDATION PLAN INTERIOR DESIGNER: CAROL MCMAHON CAROL MCMAHON INTERIOR DESIGN 22 ALI LANE LADERA RANCH, CA 923694 P.949.675.9984 DIG ALERT: 1.800.227.2600 SOUTHERN CALIFORNIA EDISON: 1.714.895.0246 SOUTHERN CALIFORNIA GAS: 1.800.427.2000 CITY WATER & SEWER: 1.949.644.3011 PACIFIC BELL TELEPHONE: 1.800.750.2355 CITY OF NEWPORT BEACH PUBLIC WORKS DEPT.: 1.949.644.3311 CITY OF NEWPORT BEACH PLANNING DEPT.: GENERAL INFOMATION: 1.949.644.3200 ZONING INFORMATION:1.949.644.3204 CITY OF NEWPORT BEACH BUILDING DEPT.: GENERAL:1.949.644.3275 PERMITS:1.949.644.3288 INSPECTIONS:1.949.644.3255 NEWPORT BEACH FIRE DEPARTMENT:1.949.644.3106 ORANGE COUNTY HEALTH SERVICES:1.714.834.3882 NOTE: DEFERRED SUBMITTALS TO BE REVIEWED BY PROJECT ARCHITECT OR ENGINEER OF RECORD AND CERTIFIED PRIOR TO SUBMITTAL TO LOCAL AGENCY FOR REVIEW. C.N.B. NOTE:CHRISTOPHER BRANDON, PRINCIPAL ARCHITECT IS THE DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE OF THE PROJECT, RESPONSIBLE FOR REVIEWING AND COORDINATING SUBMITTAL DOCUMENTS PREPARED BY OTHERS, INCLUDING PHASED AND DEFERRED SUBMITTAL ITEMS, FOR COMPATIBILITY WITH THE DESIGN OF THE BUILDING. (NBMC 15.02.010) 1.LANDSCAPE PLAN; BBQ; FIRE PIT; ACCESSORY STRUCTURES, MASONRY OR CONCRETE WALLS/FENCES; RETAINING WALLS OVER 4 FT. HIGH FROM THE BOTTOM OF THE FOUNDATION TO THE TOP OF WALL; UNDER SEPERATE SUBMITTAL (FOR H.O.A. PURPOSES). 2. POOLS, SPAS, WALLS, FENCES, PATIO COVERS AND OTHER FREESTANDING STRUCTURES REQUIRE SEPARATE REVIEWS AND PERMITS. 3. SUBMIT SOUND ATTENUATION DESIGN FOR HVAC EQUIPMENT PER ARI STD. 275. SOUND LEVEL NOT TO EXCEED 50dBA (55dBA WITH TIMER, 65dBA WITH TIMER AND NEIGHBORS CONSENT). LOCATION OF MEASUREMENT TO BE AT ADJACENT PROPERTY PATIO OR OPENING. 4. A CAL-OSHA PERMIT IS REQUIRED FOR EXCAVATIONS DEEPER THAN 5' AND FOR SHORING AND UNDERPINNING. CONTRACTOR TO PROVIDE A COPY OF OSHA PERMIT. 5. FIRE SPRINKLERS REQUIRED, CONSTRACTOR TO SUBMIT FIRE SPRINKLER DRAWINGS FOR ARCHITECT'S APPROVAL PRIOR TO SUBMITTING TO CITY. OBTAIN FIRE SPRINKLER PERMIT PRIOR TO CALLING FOR ROOF SHEATHING INSPECTION. 6. GLASS GUARD/HANDRAILS LEGAL DESCRIPTION: LOT INFORMATION: ZONED: R-1 SITE AREA:3,731.73 S.F. BUILDABLE AREA: 2,843.13 S.F. TOTAL ALLOWABLE AREA: 2 x 2,843.13 S.F. = 5,686.26 S.F. REQ'D. OPEN VOLUME = 2,843.13 X .15 = 426.47 MAX. THIRD FLR. ALLOWABLE = 2,843.13 X .15 = 426.47 OPEN VOLUME PROVIDED = 567 EXISTING BUILDING INFORMATION: EXISTING SINGLE FAMILY W/ GARAGE TO BE DEMOLISHED EXISTING S.F. = 1,717.47 S.F. (363.44 S.F.) GARAGE ZONING INFORMATION: FRONT SETBACK: 9 FT. REAR SETBACK: 0 FT. LEFT SETBACK: 3 FT. RIGHT SETBACK: 3 FT. BUILDABLE AREA: 2,843.13 S.F. APN: 047 251 18 LOT 6 , BLOCK 11, TRACT NO. 234, CITY OF NEWPORT BEACH, COUNTY OF ORANGE, STATE OF CALIFORNIA M.M. 107/1-7 1120 W. OCEANFRONT, NEWPORT BEACH, CA 92661 NO. REVISION DATENO. REVISION DATE TITLE 24 CONSULTANT: TBD THE SUBJECT PROPERTY IS LOCATED IN NEWPORT BEACH, CA ON W OCEAN FRONT. THE LOT IS APPOXIMATLY 36.39' WIDE BY 102.51' DEEP, IT IS ZONED R-1 AND IS APPX. 3,731.73 S.F. THE PROPERTY INCLUDES A 2 STORY SINGLE FAMILY RESIDENCE TO BE DEMOLISHED. CLIENT PROPOSES TO BUILD A NEW 3 STORY SINGLE FAMILY RESIDENCES OF APPX. 4,522 S.F. INCLUDING AN ATTACHED 3-CAR GARAGE OF APPX. 647 S.F. TO BE WOOD FRAMED WITH A SLAB FOUNDATION. THE PROJECT WILL BE CONTEMPORARAY WITH SOME TRANSITIONAL ACCENTS. THE HOME WILL INCLUDED BUT NOT LIMITED TO THE FOLLOWING: AMPLED INDOOR/OUTDOOR LIVING SPACES, PARKING WILL BE PROVIDED IN THE FORM OF A 3-CAR GARAGE. THE EXTERIOR MATERIALS WILL BE OF A RICH QUALITY AND HIGH DURABILITY; CONSISTING PRIMARILY OF STUCCO, VERTICAL WOOD SIDING, AND THE USE OF SOME METAL & STONE. THE HOME WILL HAVE (3) BEDROOM, (3) FULL BATH, (1) HALF BATH AND A BONUS ROOM BURKE STRUCTURAL ENGINEERS, PC 151 KALAMUS, BLDG. E-140 COSTA MESA, CA 92626 P:657.289.0460 TOAL ENGINEERING, INC. VIKTOR P. MEUM, LIC. NO. 8682 139 AVENIDA NAVARRO SAN CLEMENTE, CA 92672 P: 949.492.8586 WWW.TOALENGINEERING.COM LANDSCAPE AREA SCHEDULE NAME AREA COMMENTS 1. REF. STRUCT. SHTS. FOR SPECIAL INSPECTION BY ENGINEER OF RECORD 2. HERS VERIFICATION REQUIRED, REF. T-24 ENERGY CALCULATIONS RUDY SAINS HERITAGE ENERGY GROUP P.949.789.7221 4522 19 JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONSOWNER INFORMATION:PROJECT NAME STATUS These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT T-1.1 06/22/18 1120-2018GENERAL ARCHITECTURAL NOTESFANTICOLA RESIDENCE FANTICOLARESIDENCEANTONY & JOANNFANTICOLA1120 W. OCEAN FRONTNEWPORT BEACH, CA92661CDP 1120 W. OCEANFRONTNEWPORT BEACH, CA 92661CAITLIN SMITH 1GENERAL NOTES ABBREVIATIONS 2 DEFINITIONS: SPECIFICATIONS SHALL MEAN: WRITTEN SPECIFICATIONS IN THE PLANS OR THE "PROJECT MANUAL" (IF PROVIDED FOR THIS PROJECT) CONTRACT DOCUMENTS SHALL MEAN: WORKING DRAWINGS APPROVED FOR BUILDING PERMIT, PLUS ANY CHANGE ORDERS OR ADDENDA TO SAME. CONTRACTOR SHALL MEAN: ARCHITECT SHALL MEAN: BRANDON ARCHITECTS, INC., CHRISTOPHER BRANDON PRINCIPAL OWNER SHALL MEAN: (AS USED IN THESE SPECIFICATIONS) LICENSED GENERAL CONTRACTOR HIRED TO PERFORM THE WORK UNDER THIS CONTRACT 1. CODES/GENERAL PROVISIONS: ALL WORK, CONSTRUCTION AND MATERIALS SHALL COMPLY WITH ALL PROVISIONS OF THE APPLICIABLE BUILDING CODES AND WITH OTHER RULES, REGULATIONS AND ORDINANCES GOVERNING THE PLACE OF CONSTRUCTION. IT IS THE RESPONSIBILITY OF THE CONTRACTOR, SUB-CONTRACTORS, AND ANYONE SUPPLYING LABOR AND/OR MATERIAL TO BRING TO THE ATTENTION OF THE ARCHITECT (VERBALLY AND IN WRITING) ANY KNOWN DISCREPANCIES OR CONFLICT BETWEEN THE REQUIREMENTS OF THESE CODES AND THE CONTRACT DOCUMENTS (DRAWINGS). THE APPLICABLE CODES SHALL INCLUDE, BUT SHALL NOT BE LIMITED TO THOSE AS LISTED IN "CODE REVIEW" BOX. (T-1) ALL WORK SHALL BE PERFORMED SO AS TO COMPLY WITH ALL LEGAL AND INDUSTRY REQUIREMENTS AND STANDARDS INCLUDING THE FOLLOWING: THE BUILDING CODES, 2016 EDITIONS, AS ADOPTED BY CALIFORNIA, ALL APPLICABLE RELATED SPECIALTY CODES. THE FUNCTIONALITY STANDARDS SET FORTH IN TITLE 7 OF THE CALIFORNIA CIVIL CODE (THE "RIGHT TO REPAIR ACT"). ANY WORK TIME RESTRICTIONS IMPOSED BY THE CITY OF NEWPORT BEACH. THE MANUFACTURER'S REQUIREMENTS OF RECOMMENDATIONS FOR ANY INCORPORATED PRODUCTS. 2. FEES: CONTRACTOR AND HIS SUB-CONTRACTORS SHALL OBTAIN AND PAY FOR ALL PERMITS, LICENSES, CONSTRUCTION TAXES AND FEES REQUIRED BY CITY, COUNTY AND STATE LAWS EXCEPT THE GENERAL BUILDING PLANCHECK FEE AND REQUIRED REFUNDABLE DEPOSITS WHICH WILL BE PAID BY THE OWNER. CONTRACTOR SHALL ARRANGE FOR ALL METER INSTALLATIONS AND PAY ALL FEES FOR SAID METERS. CONTRACTOR SHALL PROVIDE TEMPORARY TOILET FACILITIES AND EROSION CONTROL MEASURES AS REQUIRED BY STATE AND LOCAL BUILDING CODE. 3. CONTRACTOR'S SURVEY: CONTRACTOR SHALL VISIT THE JOB SITE AND BE RESPONSIBLE FOR HAVING COMPLETE KNOWLEDGE OF EXISTING CONDITIONS. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS WITH THOSE SHOWN ON THE DRAWINGS AND SHALL VERIFY GRADES, CONDITIONS AND DIMENSIONS PRIOR TO COMMENCING DEMOLITION AND CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY VERBALLY AND IN WRITING OF DISCREPANCIES BETWEEN ACTUAL CONDITIONS AND THOSE DEPICTED IN THE CONTRACT DOCUMENTS. CONTRACTOR SHALL NOTIFY ARCHITECT IMMEDIATELY VERBALLY AND IN WRITING OF ANY DISCREPANCIES FOUND WITHIN THE DRAWINGS AND SPECIFICATIONS. 4. COORDINATION OF CONSTRUCTION: CONTRACTOR IS SOLELY RESPONSIBLE FOR THE ACCURACY OF DETAILS; FOR CONFIRMING AND COORDINATING ALL QUANTITIES AND DIMENSIONS; FOR SELECTING FABRICATION PROCESSES; FOR TECHNIQUES OF ASSEMBLY AND PERFORMANCE OF ALL WORK IN A SAFE AND SATISFACTORY MANNER. CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF ALL WORK INCLUDING THAT OF THE SUB-CONTRACTORS. CONTRACTOR SHALL PROVIDE SUPERVISION OF THE JOB DURING ALL PHASES OF CONSTRUCTION ACTIVITIES. A COMPETENT SUPERINTENDENT SHALL BE SELECTED BY THE CONTRACTOR AND SHALL BE IN CHARGE OF THE JOB UNTIL ITS COMPLETION. CONTRACTOR AGREES TO BIND EVERY SUB-CONTRACTOR BY THE TERMS OF THE CONTRACT AS FAR AS SUCH TERMS ARE APPLICABLE TO THE SUB-CONTRACTOR'S WORK. 5. CLEAN-UP: ALL SUB-CONTRACTORS SHALL BE RESPONSIBLE FOR THE DAILY REMOVAL OF ALL DEBRIS ACCUMULATED AS A RESULT OF THEIR OPERATIONS. ALL SCRAP DEBRIS AND OTHER EXCESS MATERIAL SHALL BE LAWFULLY REMOVED FROM THE SITE, UNLESS OTHERWISE DIRECTED BY THE CONTRACTOR. 6. TESTS AND PERMITS: CONTRACTOR SHALL ARRANGE FOR, AND SECURE REQUIRED TESTS, PERMITS AND INSPECTIONS, AND SHALL BEAR COSTS FOR SAME. 7. GUARANTEES: CONTRACTOR SHALL GUARANTEE ALL WORK, MATERIALS AND PRODUCTS FOR ONE YEAR AFTER THE DATE OF ACCEPTANCE OF THE WORK AND CONTRACTOR SHALL REPAIR OR REPLACE, OR CAUSE TO BE REPAIRED OR REPLACED ANY OR ALL SUCH WORK TOGETHER WITH ANY OTHER WORK WHICH MAY BE DISPLACED IN DOING SO, THAT MAY PROVE DEFECTIVE WITHIN ONE YEAR, WITHOUT ADDITIONAL EXPENSE; ORDINARY WEAR AND TEAR, UNUSUAL ABUSE OR NEGLECT IS EXCEPTED. EXCEPTIONS TO ONE YEAR GUARANTEE ARE SPECIFIED IN OTHER SECTIONS OF THE PROJECT MANUAL OR DRAWINGS. STATE LAW, OR MANUFACTURER'S GUARANTEE SHALL GOVERN IF LENGTH AND TYPES OF GUARANTEES ARE MORE STRICT OR FOR LONGER PERIODS. IT IS UNDERSTOOD BY CONTRACTOR THAT IT IS HIS RESPONSIBILITY TO PROVIDE MATERIALS AND CONSTRUCTION WHICH WILL YIELD A REASONABLE VALUE OVER A PERIOD OF TIME WHICH MAY EXCEED THE SPECIFIED GUARANTEE AND WARRANTY PERIODS. CONTRACTOR SHALL BE RESPONSIBLE FOR A WEATHER TIGHT BUILDING, FREE FROM DEFECTS OF MATERIALS AND WORKMANSHIP. EACH SUB-CONTRACTOR SHALL PROVIDE A WRITTEN GUARANTEE STATING THAT WORK EXECUTED BY HIM IS FREE AND WILL REMAIN FREE FROM DEFECTS OF MATERIALS AND WORKMANSHIP FOR ONE YEAR FROM DATE OF ACCEPTANCE OF HIS WORK BY OWNER, AND THAT REPAIR AND REPLACEMENT OF SUCH DEFECTIVE WORK AND ALL OTHER WORK DAMAGED AS A RESULT THEREBY WILL BE EXECUTED IN A TIMELY MANNER AT THE CONVENIENCE OF THE OWNER AND WITHOUT COST TO OWNER. 8. WAIVER OF LIENS: CONTRACTOR SHALL PROVIDE CERTIFIED RELEASE OF LIENS BY ALL SUB-CONTRACTORS AND SUPPLIERS, OR ANYONE PROVIDING MATERIALS AND/OR LABOR AS THEY BECOME AVAILABLE. 9. ROLL OF ARCHITECT DURING CONSTRUCTION: THE ARCHITECT WILL NOT ACT AS THE OWNER'S REPRESENTATIVE DURING CONSTRUCTION. ARCHITECT WILL ADVISE AND CONSULT WITH OWNER. ARCHITECT WILL OBSERVE CONSTRUCTION PER HIS AGREEMENT WITH OWNER AND RENDER INTERPRETATIONS NECESSARY FOR THE PROPER EXECUTION OR PROGRESS OF THE WORK IN ACCORDANCE WITH THE INTENT OF THE PLANS AND SPECIFICATIONS. ARCHITECT WILL NOT BE RESPONSIBLE OR HAVE CONTROL OR CHARGE OVER THE ACTS OR OMISSIONS, CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS, OF THE CONTRACTOR, SUB-CONTRACTORS, OR ANY OF THEIR AGENTS OR EMPLOYEES, OR ANY OTHER PERSONS PERFORMING ANY OF THE WORK. ANY VERBAL INSTRUCTION OR AUTHORIZATION THAT IS CONFIRMED BY LETTER, MEETING NOTE, MEMORANDA, OR THE LIKE, (WITH A COPY SENT TO THE OWNER, OR THE OWNER'S REPRESENTATIVE) & THERE IS NO EXCEPTION TAKEN WITHIN (10) CALENDAR DAYS, SHALL BE DEEMED EQUIVALENT TO RECEIPT OF WRITTEN INSTRUCTION, APPROVAL AND AUTHORIZATION FROM THE OWNER. 10. A.I.A. GENERAL CONDITIONS: THE CURRENT GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION PUBLISHED BY THE AMERICAN INSTITUTE OF ARCHITECTS SHALL APPLY AS THOUGH IT WERE PART OF THESE DOCUMENTS UNLESS SPECIFICALLY MODIFIED IN THE OWNER/CONTRACTOR AGREEMENT. A COPY OF SAID GENERAL CONDITIONS MAY BE OBTAINED FROM THE ARCHITECT UPON REQUEST. THE NOTES CONTAINED IN THESE "GENERAL NOTES" ON THIS SHEET ARE INTENDED TO SUMMARIZE AND COMPLIMENT THE A.I.A. GENERAL CONDITIONS. THE A.I.A. GENERAL CONDITIONS SHALL TAKE PRECEDENCE OVER THESE NOTES SHOULD A CONFLICT IN WORDING OCCUR. 11. EXTRAS: OWNER MAY ORDER EXTRA WORK OR MAKE CHANGES BY ALTERING, ADDING TO OR DEDUCTING FROM THE WORK, THE CONTRACT SUM BEING ADJUSTED TO THE MUTUAL SATISFACTION OF THE OWNER, ARCHITECT AND CONTRACTOR. BEFORE ANY CHANGES ARE BEGUN, THE ADDED OR DEDUCTED SUM SHALL BE PRESENTED TO OWNER IN WRITING FOR APPROVAL. 12. SUBSTITUTIONS: SUBSTITUTIONS OF MATERIALS OR METHODS PROPOSED BY THE CONTRACTOR OR HIS SUB-CONTRACTORS CONTRARY TO DRAWINGS AND SPECIFICATIONS SHALL BE SUBMITTED TO ARCHITECT IN WRITING FOR APPROVAL OR DENIAL. IF MORE THAN ONE MANUFACTURER IS SPECIFIED IN THE PLANS OR SPECIFICATIONS, IT SHALL BE THE CONTRACTOR'S OPTION TO SELECT THE ONE WHICH HE MAY DESIRE. IF MORE THAN ONE FINISH OR STYLE IS AVAILABLE IN THE ITEM SPECIFIED, CONTRACTOR SHALL BE OBLIGATED TO NOTIFY ARCHITECT VERBALLY AND IN WRITING OF THIS FACT FOR ARCHITECT'S AND OWNER'S DECISION. WHERE THE TERM "OR EQUAL" IS USED IN DRAWINGS OR SPECS IT SHALL BE UNDERSTOOD THAT THE REFERENCE IS MADE SUBJECT TO THE RULING AND JUDGMENT OF THE ARCHITECT AND SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW AND APPROVAL. ACTUAL SAMPLES OF THE SUBSTITUTIONS SHALL ALSO BE SUBMITTED TO THE ARCHITECT FOR REVIEW AND APPROVAL. 13. INSURANCE: CONTRACTOR SHALL CARRY GENERAL LIABILITY INSURANCE WITH BROADFORM PROPERTY DAMAGE ENDORSEMENT AND CONTINGENT LIABILITY ENDORSEMENT. OWNER AND ARCHITECT SHALL BE LISTED AS ADDITIONAL INSURERS UNDER THE POLICY WITH WAIVER OF SUBROGATION. CONTRACTOR SHALL FURNISH OWNER WITH A CERTIFICATE OF INSURANCE WITH A 30 DAY NOTICE OF CANCELLATION. OWNER SHALL OBTAIN A BUILDER'S RISK POLICY WITH ARCHITECT NAMED AS AN ADDITIONAL INSURED WITH WAIVER OF SUBROGATION. 14. SCOPE OF DRAWINGS AND SPECIFICATIONS: THESE DRAWINGS AND SPECIFICATIONS SHALL BE INTENDED TO SHOW AND DESCRIBE DETAILS FOR A CONSTRUCTIBLE BUILDING. PARTS AND DETAILS NOT FULLY SHOWN OR DESCRIBED SHALL BE DETAILED AND EXECUTED ACCORDING TO STANDARD FIRST CLASS PRACTICE AND IN SIMILAR MANNER AND SPIRIT OF THE DETAILS WHICH ARE SHOWN ON THE DRAWINGS AND/OR DESCRIBED IN THE PROJECT MANUAL. IF CONTRACTOR OR SUB-CONTRACTOR FINDS ANY DETAILS WHICH, IN HIS OPINION, ARE UNSOUND, UNSAFE, OR NOT WATERPROOF, IT IS HIS DUTY TO NOTIFY ARCHITECT IN WRITING OF THIS FACT. IF WORK IS PERFORMED AS DETAILED, IT WILL BE ASSUMED THAT THERE ARE NO OBJECTIONS TO THE DETAIL. ACCURACY OF ALL DIMENSIONS SHALL BE CHECKED. NO EXTRA COMPENSATION WILL BE ALLOWED FOR DIFFERENCE BETWEEN ACTUAL DIMENSIONS AND THOSE INDICATED ON THE DRAWINGS. IN USING THESE PLAN FOR BIDDING OR CONSTRUCTION PURPOSES, ALL CONTRACTORS ARE REQUIRED TO REVIEW AND TREAT THEM AS A WHOLE IN ORDER TO IDENTIFY ALL REQUIREMENTS THAT DIRECTLY OR INDIRECTLY AFFECT THEIR PORTION OF THE WORK, EVEN REQUIREMENTS LOCATED IN SECTIONS DESIGNATED AS APPLICALBE TO OTHER TRADES. IN CAS OF CONFLICTS, THE AFFECTED CONTRACTOR IS REQUIRED TO EITHER OBTAIN DIRECTION FROM AN APPROPRIATE REPRESENTATIVE OF THE OWNER, OR OTHERWISE TO APPLY THE MORE STRINGENT STANDARD. THESE PLANS ARE INTENDED TO SET FORTH THE REQUIREMENTS FOR CONSTRUCTION IN ONLY AN INDUSTRY-STANDARD LEVEL OF QUALITY AND DETAIL, AND THE ARE INTENDED TO BE SUPPLEMENTED BY APPROPRIATE REQUESTS FOR CLARIFICATION AND INFORMATION. ERRORS AND OMISSIONS ARE TO BE EXPECTED AND ANTICIPATED, AND ALL CONTRACTORS ARE REQUIRED TO CAREFULLY REVIEW THESE PLANS FOR ERRORS AND OMISSIONS AND TO BRING THESE ERRORS AND OMMISIONS TO THE ATTENTION OF A APPROPRIATE OWNER & ARCHITECT IN WRITING IN A TIMELY MANNER; AND ANY CONTRACTOR WHO FAILS TO DO SO BEFORE BIDDING OR OTHERWISE PROCEEDING ASSUMES THE RISK OF ANY CONSEQUENCES. SCALED DIMENSIONS SHOULD BE CONSIDERED ONLY APPROXIMATE; AND IN ANY DIMENSIONS BEFORE PROCEEDING WITH ANY AFFECTED PROCUREMENT, FABRICATION OR CONSTRUCTION. SCHEMATIC PLANS ARE INTENDED ONLY TO DEMONSTRATE THE RELATIONSHIP AMONG COMPONENT PARTS, AND NOT TO DEPICT SPECIFIC LOCATIONS (e.g. SCHEMATIC ELECTRICAL PLANS). 15. DIMENSIONS ON DRAWINGS: FIGURED DIMENSIONS SHALL BE FOLLOWED IN PREFERENCE TO SCALE, AND DETAIL DRAWINGS IN PREFERENCE TO SMALL SCALE DRAWINGS. SUB-CONTRACTOR AND CONTRACTOR SHALL CHECK ACCURACY OF ALL DIMENSIONS IN THE FIELD PRIOR TO ANY WORK BEING CONSTRUCTED OR MATERIALS OR PRODUCTS FABRICATED OR ORDERED. SPECIFICATIONS AND WRITTEN NOTES AND SCHEDULES ON DRAWINGS SHALL BE FOLLOWED IN PREFERENCE TO INFORMATION FURNISHED IN THE FORM OF LINE DRAWINGS. DETAILED DRAWINGS FURNISHED DURING CONSTRUCTION OR APPROVED BY CONTRACTOR OR ARCHITECT ARE TO BE CONSIDERED EXPLANATORY AND NOT AS CHANGES TO DRAWINGS AND SPECIFICATIONS. NOTES, FIGURES AND DETAILS ON SAID DRAWINGS SHALL BE FOLLOWED AND EXECUTED AS IF PART OF THESE DOCUMENTS. DRAWINGS ARE NOT TO BE SCALED UNLUESS PERMITTED BY THE ARCHITECT. DIMENSIONS SHALL GOVERN. ALL EXTERIOR DIMENSIONS ARE BASED ON NOMINAL SIZES OF MEMBERS AND ARE GIVEN TO THE OUTER FACE OF SUCH MEMBERS, UNLESS OTHERWISE NOTED ON DRAWINGS. INTERIOR PARTITIONS ARE DIMENSIONED FROM FACE OF STRUCTURE TO FACE OF STRUCTURE UNLESS OTHERWISE NOTED ON DRAWINGS. WHERE DIMENSION IS LABELED "CLEAR" IT IS TAKEN FROM THE FACE OF FINISH TO FACE OF FINISH OF EACH MATERIAL. PLUS OR MINUS (+/-) DIMENSIONS SHALL NOT VARY BY MORE THAN 2" WITHOUT APPROVAL BY ARCHITECT. WALL ANGLES ARE EITHER 90° OR 45° UNLESS NOTED OTHERWISE. 16. SUBMITTALS, MEETING NOTES, BULLETINS, AND MEMOS: SUBMITTALS WILL BE REVIEWED BY THE ARCHITECT, IF AT ALL, ONLY PURSUANT TO THE INDUSTRY-STANDARD PROTOCOL SET FORTH IN AIA DOCUMENT A201-1997; AND IN NO EVENT WILL THE SUBMITTAL REVIEW PROCESS RELIEVE OR LESSEN THE SUBMITTING CONTRACTOR'S RESPONSIBILITY FOR AN INAPPROPRIATE SUBMITTAL. ARCHITECT, FROM TIME TO TIME, WILL ISSUE CONSTRUCTION NOTES OR MEMOS REGARDING CONSTRUCTION ISSUES THAT HAVE ARISEN SINCE THE DRAWINGS AND SPECIFICATIONS WERE COMPLETED. CONTRACTOR SHALL REVIEW THESE WRITTEN DOCUMENTS AND INCORPORATE THEM INTO THE PROJECT. ANY QUESTIONS OR OBJECTIONS AS TO THE INTENT OF THE WRITTEN DOCUMENT ITEMS WILL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT FOR DISCUSSION AND OR CLARIFICATION. ANY ITEM THAT RESULTS IN A CHANGE TO THE COST OR TIMING OF THE PROJECT SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE OWNER & ARCHITECT PRIOR TO EXECUTING. CONTRACTOR SHALL SUBMIT FABRICATION SHOP DRAWINGS TO THE ARCHITECT FOR APPROVAL PRIOR TO ORDERING AND/OR FABRICATION. CONTRACTOR SHALL SUBMIT MANUFACTURER'S CUTS FOR ALL FIXTURES AND EQUIPMENT CALLED FOR ON THE CONSTRUCTION DOCUMENTS TO ARCHITECT INCLUDING BUT NOT LIMITED TO LIGHT FIXTURES, HARDWARE, PLUMBING FIXTURES, KITCHEN EQUIPMENT, ETC. BY SUBMITTING SHOP DRAWINGS AND PRODUCT DATA, THE CONTRACTOR REPRESENTS THAT HE/SHE HAS VERIFIED FIELD CONDITIONS, DIMENSIONS AND RELATED CONSTRUCTION AND HAS COORDINATED THE SUBMISSION CONSTUCTION WITH THE REQUIREMENTS OF ALL OTHER RELATED WORK IN THE CONSTRUCTION DOCUMENTS. ALL SHOP DRAWINGS AND CUTS MARKED "REVIEWED" BY ARCHITECT, ARE FOR VERIFCATION OF ADHERENCE TO THE DESIGN INTENT ONLY. THE CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR ALL MEANS AND METHODS AND ERRORS AND OMISSIONS ON THEIR DRAWINGS. CONTRACTOR TO SUBMIT A COMPLETE SHOP DRAWINGS AND OR SUBMITTAL FOR APPROVAL BEFORE COMMENCING FABRICATION AND/OR INSTALLATION OF ALL APPLICABLE ITEMS. ALL SHOP DRAWINGS DIMENSIONS SHALL BE FIELD VERIFIED, REVIEWED AND APPROVED BY CONTRACTOR BEFORE SUBMITTAL. SHOP DRAWINGS WHICH ARE INCOMPLETE OR LACKING SUFFICIENT INFORMATION WILL BE RETURNED WITHOUT REVIEW. SUBMIT SAMPLES FOR INITIAL SELECTION PURPOSES OF ACTUAL VENEERS SHOWING A FULL RANGE OR GRAIN VARIATION, FINISH AND PATTERNS PROPOSED. SUBMIT SAMPLES AS REQUIRED UNTIL APPROVED BY ARCHITECT. SAMPLES SHALL BE 12" X 12" MIN., ONE UNIT OF EACH TYPE AND FINISH. 17. ERRORS AND OMISSIONS: ERRORS OR OMISSIONS WHICH APPEAR ON THE DRAWINGS, IN SPECIFICATIONS OR OTHER CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT BY THE CONTRACTOR AND TO THE CONTRACTOR BY THE SUB-CONTRACTOR IN WRITING. IN EVENT OF FAILURE OF SUB-CONTRACTOR TO GIVE SUCH WRITTEN NOTIFICATION BEFORE CONSTRUCTION OR FABRICATIONS OF THE WORK, HE WILL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY SUCH ERRORS OR OMISSIONS AND THE COSTS OF RECTIFYING SAME. HOWEVER, DRAWINGS AND SPECIFICATIONS ARE COMPLEMENTARY AND WORK CALLED FOR ON ONE AND NOT THE OTHER SHALL BE PROVIDED AS THOUGH FULLY SET FORTH IN BOTH. 18. BARRICADES: CONTRACTOR SHALL ERECT AND PROPERLY MAINTAIN AT ALL TIMES AS REQUIRED BY CONDITIONS AND PROGRESS OF THE WORK, ALL NECESSARY PROTECTIVE BARRICADES, FENCES AND OTHER SAFEGUARDS FOR THE PROTECTION OF THE WORKERS AND THE PUBLIC. THESE BARRICADES SHALL BE CONSTRUCTED AND BE LOCATED AS SHALL BE DETERMINED BY LOCAL AUTHORITIES AND CODES. 19. TEMPORARY BRACING: AT ALL TIMES DURING CONSTRUCTION ACTIVITIES OR ERECTION OF PROJECT OR ITS COMPONENT PARTS, PRIOR TO COMPLETION OF THE STRUCTURAL FRAME OR REPLACEMENT AND PERMANENT CONNECTION OF COMPONENT MEMBERS TO THE STRUCTURAL FRAME, SUB-CONTRACTORS SHALL PROVIDE, INSTALL AND MAINTAIN PROPERLY DESIGNED AND CONSTRUCTED TEMPORARY BRACING OF ADEQUATE STRENGTH TO PREVENT DISLOCATION, DISTORTION, CRACKING, FALLING OFF, OR ANY OTHER DAMAGE TO WORK OR ANY OF ITS COMPONENT PARTS DUE TO FORESEEABLE NORMAL AS WELL AS NOT FORESEEABLE EXCESSIVE WIND AND EARTHQUAKE FORCES WITHOUT ADDITIONAL COST TO OWNER. CONTRACTOR AND HIS SUB-CONTRACTORS SHALL, AT THEIR EXPENSE, REPLACE OR REPAIR, AS DIRECTED, DAMAGED PORTIONS OF THEIR WORK OR COMPONENT PARTS. 20. TOXIC SUBSTANCES REMOVAL: PRIOR TO ANY WORK BEING PERFORMED, WHENEVER THERE ARE EXISTING STRUCTURES TO BE REMOVED OR ALTERED, CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION AND REMOVAL OF ANY TOXIC MATERIALS OR SUBSTANCES AS REQUIRED BY THE STATE OF CALIFORNIA INCLUDING BUT NOT LIMITED TO ASBESTOS, LEAD PAINTS, MOLD, ETC. REMOVAL AND DISPOSAL SHALL FOLLOW STATE MANDATED METHODS, PROCEDURES, DOCUMENTATION AND APPLICATION REQUIREMENTS. 21. NO CHANGES ARE TO BE MADE ON THESE PLANS WITHOUT THE KNOWLEDGE OR CONSENT OF THE ARCHITECT/ ENGINEER WHOSE SIGNATURE APPEARS HERON. 22. NO FRAMING OF ANY TYPE TO BE CONCEALED PRIOR TO INSPECTION BY GOVERNING AGENCIES. 23. REFERENCES TO ANY DETAIL OR DRAWINGS IS FOR CONVENIENCE ONLY AND DOES NOT LIMIT THE APPLICATION OF SUCH DETAIL OR DRAWINGS. 24. USE 2x6 MINIMUM STUDS FOR PLUMBING WALLS 25. MAXIMUM FLOW RATE STANDARDS SET BY THE CURRENT CALIFORNIA GREEN CODE - G.C. TO VERIFY PRIOR TO PURCHASE AND INSTAL. OF ANY FIXTURES. 26. EXTERIOR DECKS, BALCONIES, AND STAIRWAYS SEALED UNDERNEATH SHALL BE WATERPROOFED- ARCH. TO APPV. METHOD OF WATERPROOFING - G.C. TO SUBMIT SPECIFICATIONS. 27. SPECIAL INSPECTION IS REQUIRED FOR THE FOLLOWING: * FOUNDATION INSPECTION BY SOILS ENGINEER PRIOR TO CONCRETE POUR AND: * PER SOILS REPORT: OVER EXCAVATION, RECOMPACTION, FOOTING DEPTH, UTILITY TRENCH BACK FILL * RETAINING WALL BACK FILL, PRE SATURATION OF SLAB AREAS, EXTERIOR FLAT WORK AREAS. * ALL TO BE ADDRESSED IN A REPORT PRESENTED TO BUILDING DEPT. PRIOR TO FINAL * ALL FIELD WELDING OF STRUCTURAL STEEL * INSTALLATION OF ALL HIGH STRENGTH BOLTS * CERTIFICATION OF WELD, & BOLTING TO BE GIVEN TO BUILDING DEPARTMENT PRIOR TO FRAMING INSPECTION. 28. MAX. TEMP. OF 120° TO BE APPROVED BY THE USE OF PRESSURE BALANCE OR THERMOSTATIC MIXING VALVES TYP. @ SHOWERS & TUBS. 29. MAINTENANCE INFORMATION: THE BUILDER SHALL PROVIDE TO THE BUILDING OWNER AT OCCUPANCY MAINTENANCE INFORMATION FOR ALL FEATURES, MATERIALS, COMPONENTS, AND MANUFACTURED INFORMATION FOR ALL FEATURES, MATERIALS, COMPONENTS AND MANUFACTURED DEVICES THAT REQUIRE ROUTINE MAINTENANCE FOR EFFICIENT OPERATION. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY STATED AND INCORPORATED ON A READILY ACCESSIBLE LABEL. THE LABEL MAY BE LIMITED TO IDENTIFYING, BY TITLE AND/OR PUBLICATION NUMBER, THE OPERATION AND MAINTENANCE MANUAL FOR THAT PARTICULAR MODEL AND TYPE OF FEATURE, MATERIAL, COMPONENT, OR MANUFACTURED DEVICE. 30. AFTER INSTALLING WALL, CEILING, OR FLOOR INSULATION, THE INSTALLER SHALL MAKE AVAILABLE TO THE ENFORCEMENT AGENCY OR POST IN A CONSPICUOUS LOCATION IN THE BUILDING A CERTIFICATE SIGNED BY THE INSTALLER STATING THAT THE INSTALLATION IS CONSISTENT WITH THE PLANS AND SPECIFICATIONS FOR WHICH THE BUILDING PERMIT WAS ISSUED. THE CERTIFICATE SHALL ALSO STATE THE MANUFACTURER'S NAME AND MATERIAL IDENTIFICATION, THE INSTALLED R-VALUE, AND (IN APPLICATIONS OF LOOSE FILL INSULATION) THE MINIMUM INSTALLED WEIGHT PER SQUARE FOOT CONSISTENT WITH THE MANUFACTURER'S LABELED INSTALLED DESIGN DENSITY FOR THE DESIRED R- VALUE. 31. ON PROJECTS WITH EXCAVATIONS THAT WILL BE LOWER THAN ADJOINING PROPERTIES, 30 DAY NOTICE IS LEGALLY REQUIRED BY THE OWNERS & CONTRACTORS TO THE ADJOINING PROPERTY OWNERS OUTSIDE THE SETBACK AREA. 32. DISTANCE FROM THE FACE OF FOUNDATION TO PROPERTY LINE TO BE ZONING SETBACK PLUS WALL FINISH THICKNESS. 33. ROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR FIXTURES SHALL BE PROVIDED WITH ON EXHAUST FAN WITH A MINIMUM CAPACITY OF 50 CFM. DUCTLESS FANS ARE UNACCEPTABLE. CBC 1203.4.3.2.1, CMC T-4-4 34. SAFETY GLAZING SHALL BE PROVIDED AT THE FOLLOWING HAZARDOUS LOCATIONS: CBC 2406.3 A. SWINGING AND SLIDING DOORS B. WHEN LOCATED WITHIN 60- INCHES OF THE FLOOR SURFACE IN TUBS, SHOWERS, SUANAS, OR STEAM ROOMS. C. WITHIN A 24-INCH ARC OF EITHER VERTICAL EDGE OF DOORS AND WITHIN 60-INCHES OF WALKING SURFACE. D. WHERE GLAZING AREA IS MORE THAN 9 SQ. FT. IN AREA, WITH A BOTTOM EDGE LESS THAN 18-INCHES ABOVE THE FLOOR AND TOP EDGE MORE THAN 36-INCHES ABOVE FLOOR. E. ADJACENT TO STAIRWAYS, LANDINGS AND RAMPS WITHIN 36-INCHES HORIZONTALLY OF WALKING SURFACE AND WITHIN 60-INCHES ABOVE WALKING SURCFACE. F. ADJACENT TO STAIRWAYS WITHIN 60-INCHES HORIZONTALLY OF BOTTOM TREAD OF STAIRWAY AND EXPOSED SURFACE IS WITHIN 60-INCH ABOVE NOSE OF TREAD. 35. CLEARANCE FOR WATER CLOSET TO BE A MINIMUM OF 24-INCHES IN FRONT AND 15-INCHES FROM ITS CENTER TO ANY SIDE WALL OR OBSTRUCTION. CPC 407.5 36. THE NET AREA OF THE SHOWER ENCLOSURE SHALL BE 1,024 SQ. INCHES (7.1 SQ. FT.) OR MORE IN THE CLEAR FLOOR AREA, AND SHALL ALSO BE CAPABLE OF ENCOMPASSING A 30-INCH DIAMETER CIRCLE. CPC 411.7 37. WALL COVERINGS OR SHOWERS OR TUBS WITH SHOWERS SHALL BE OF CEMENT PLASTER, TILE, OR APPROVED EQUAL, TO A HEIGHT OF NOT LESS THAN 70-INCHES ABOVE DRAIN INLET. PROVIDE CEMENT BOARD OR CEMENT PLASTER BACKING FOR TILE. CBC 1210.3 38. MIN. 5/8" TYPE 'X' MOISTURE RESISTANT GYPSUM WALL BOARD IN ALL BATHROOMS AND KITCHENS 39. EXTERIOR LATH AND PLASTER: PROVIDE TWO LAYERS OF GRADE D PAPER OVER ALL WOOD BASE SHEATHING. CBC 2510.6 40. THE WATER HEATER BURNER TO BE AT LEAST 18-INCHES ABOVE THE GARAGE FLOOR, IF LOCATED IN A GARAGE. CPC 508.14 41. PROVIDE A 3-INCH DIAMETER BY 3-FOOT TALL STEEL PIPE EMBEDDED IN CONCRETE SLAB FOR PROTECTION OF WATER HEATERS IN GARAGE. CPC 508.14 42. WATER HEATERS TO BE STRAPPED AT TOP AND BOTTOM WITH 1-1/2" X 16 GAUGE STRAP WITH 3/8" DIA. X 3" LAG BOLT EACH IND. CPC 508.2 43. DRYER: THE CLOTHES DRYERS VENT SHALL NOT EXCEED 14-FEET IN OVERALL LENGTH. CMC 504.3.2 DRYER VENT TERMINATION MUST BE 3 FT. CLEAR FROM OPENINGS INTO THE BUILDING ( DOORS AND OPERABLE WINDOWS) . CMC 504.5 PROVIDE A MIN. 100 SQ.IN. OPENING IN THE DRYER DOOR. CMC. 504.3.2 44. SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS (R314.3): A. IN EACH SLEEPING ROOM. B. OUTSIDE EACH SEPERATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS C. ON EVERY LEVEL OF DWELLING, INCLUDING BASEMENTS AND HABITABLE ATTICS. SMOKE ALARMS SHALL BE HARDWIRED WITH BATTERY BACK-UP AND INTERCONNECTED UNLESS EXEMPTED IN ACCORDANCE WITH SECTIONS R314.4 & R314.5 45. CARBON MONOXIDE ALARMS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS (R315.3): A. OUTSIDE OF EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOM(S) B. ON EVERY LEVEL OF THE DWELLING UNIT INCLUDING BASEMENTS. CARBON MONOXIDE ALARMS SHALL BE HARDWIRED WITH BATTERY BACK-UP AND INTERCONNECTED UNLESS EXEMPTED IN ACCORDANCE WITH SECTIONS R314.4 & R314.5 46. ALL RECEPTACLE OUTLETS IN BATHROOMS, ABOVE KITCHEN COUNTERTOP, CRAWL SPACES, GARAGE, ROOFTOPS, OUTDOOR OUTLETS, WITHIN 6-FEET OF WET BAR SINK/LAUNDRY SINK TO BE PROTECTED BY GROUND FAULT CIRCUIT INTERRUPTER (GFCI) CEC 210.8 47. ALL 120V SINGLE PHASE, 15 AND 20 AMP OUTLETS (RECEPTACLES, LIGHTING, SMOKE DETECTORS, ETC.) TO BE PROTECTED BY COMBINATION TYPE ARC-FAULT CIRCUIT INTERRUPTER (AFCI) CEC 210.12 48. ELECTRICAL SERVICE TO BE UNDERGROUND FOR NEW CONSTRUCTION OR ADDITIONS >50%. NBMC 12.32.015 49. INSPECTOR TO REVIEW AND APPROVE UNDERGROUND ELEC. SERVICE PRIOR TO CONCRETE PLACEMENT. 50. UTILITY COMPANY APPROVAL IS REQUIRED FOR METER LOCATION PRIOR TO INSTALLATION. 51. FACTORY-BUILT FIREPLACES, CHIMNEYS, AND ALL OTHER COMPONENTS SHALL BE LISTED AND LABELED AND SHALL BE INSTALLED IN ACCORDANCE WITH THE CONDITIONS OF THE LISTING 52. FIREPLACE: DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT THE TERMINATION OF FACTORY-BUILT CHIMNEY SYSTEMS AND ARE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS R1005.4NG. CMC (802.5.2.4) PROVIDE A PERMANENTLY ANCHORED GASEOUS FUEL BURNING PAN TO THE FIREBOX IN A SOLD FUEL BURNING FIREPLACE. SOLID FUEL BRUNING FIREPLACE MUST COMPLY WITH THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES." GAS APPLIANCE FIREPLACE MUST COMPLY WITH THE CALGREEN CODE REQUIRMENTS." 53. ALL DOORS FROM THE HOUSE INTO THE POOL AREA SHALL BE EQUIPPED WITH AN APPROVED ALARM OR AN APPROVED ALTERNATE DROWNING PREVENTION SAFETY FEATURE. CBC 3109.4.4.2 54. GENERAL CONTRACTOR, CONTRACTORS, SUB-CONTRACTORS AND BUILDERS TO COORDINATE ALL ENGINEERING AND MECHANICAL DRAWINGS WITH ARCHITECTURAL DRAWINGS BEFORE PROCEEDING WITH WORK. IF DISCREPANCIES ARE APPARENTLY OBSERVED OR INFORMATION APPARENTLY IS THOUGHT TO BE MISSING, NOTIFY ARCHITECT WITHIN 24 HOURS WITH SKETCH, DRAWING, PDF, PHOTOCOPIES WITH LEGIBLE HAND WRITTEN NOTES AND/OR WRITING (FAX, EMAIL OR CORRESPONDENCE). IF CONFLICT WITH EXISTING CONDITIONS, PROVIDE DOCUMENTATION (PHOTOS, SKETCHES, DWGS) OF EXISTING CONDITIONS AND SUGGEST PROPOSAL(S) FOR SOLUTION (SKETCH, DRAWING, AND/OR WRITING). IN CASE OF ANY DISCREPANCIES, THE ARCHITECT IS THE SOLE INTERPRETER OF THE CONTRACT DOCUMENTS. 55. ISSUANCE OF A BUILDING PERMIT DOES NOT RELIEVE APPLICANTS OF THE LEGAL REQUIREMENTS TO OBSERVE COVENANTS, CONDITIONS AND RESTRICTIONS WHICH MAY BE RECORDED AGAINST THE PROPERTY OR TO OBTAIN PLANS. YOU SHOULD CONTACT YOUR COMMUNITY ASSOCIATIONS PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION AUTHORIZED BY THIS PERMIT. 56. LAND. WALLS LOCATED IN FRONT AND BACK OF PROPERTY SHALL NOT EXCEED 42" HT. REFER. LAND. DWGS FOR LOC'T. 57. LAND. WALLS LOCATED BTW. NEIGHBORS SHALL BE SHARED ON PROP. LINE. REFER. LAND. DWGS AND SEE ATTACHED DOCUMENT FOR "AGRREMENT TO BUILD A FENCE OR WALL CENTERED OVER THE PROPERTY WALL." 58. ALL INTERIOR AND EXTERIOR JOINTS BETWEEN DIFFERENT MATERIALS OR FINISHES SHALL RECEIVE A BEAD OF CAULKING OR SEALANT TO FORM A REVEAL TO MATCH COLOR OF ADJACENT SURFACE. COORDINATE COLORS WITH ARCHITECT. 59. CONTRACTOR SHALL NOTIFY ARCHITECT FOR CLARIFICATION PRIOR TO BIDDING OF ANY DISCREPANCIES BETWEEN ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS. BID SHALL BE BASED ON THE MOST STRINGENT REQUIREMENT. 60. CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT OF ANY UNEXPECTED OR UNKNOWN FIELD CONDITIONS, ERRORS, OMISSIONS, OR DISCREPANCIES IN THE DRAWINGS, PROJECT MANUAL, OR CONTRACT DOCUMENTS PRIOR TO PROCEEDING WITH THE WORK OR SHOP FABRICATIONS. HEATING VENTILATING/AIR COND. DRINKING FOUNTAIN/DOUGLASS FIRD.F. EA. E.P. ENCL. EMER. ELEV. ELEC. EL. E.J.E. DWG. D.S.P. D.S. DR. DN. DIM. DIAG. DIA. EACH EXPANSION JOINT ELEVATION ELEVATOR EMERGENCY ENCLOSURE ELECTRIC PANEL ELECTRIC DIAMETER DIAGONAL DIMENSION DOWN SPOUT DRY STAND PIPE EAST, ENTRY DOWN DOOR DRAWING DET. DEPT. DBL. CTR. CTSK. CORR. CONT. CONST. COND. CONC. CNTR. CLR. CLKG. CLG. C.J. C.I. CHG. CHAN. C.G. CEM. C.B. CAB. CONCRETE CONDITION CONSTRUCTION CONTRACTOR/ CONTINUOUS CORRIDOR, CORROSIVE COUNTERSUNK DEPARTMENT COUNTER CENTER DOUBLE DETAIL CATCH BASIN CORNER GUARD CAST IRON CONTROL JOINT/ CONST. JOINT CAULKING CABINET CEMENT CHANNEL CHANGE CEILING CLEAR LOAD FROM ABOVE JANITOR KITCHEN LANDSCAPED AREA LABORATORY LAMINATE LAVATORY POUNDS LEFT HAND LOCKER LUMINOUS MAINTENANCE MASONRY LBS. LFA MAS. MAINT. LUM. LT. LKR. L.H. LIGHT LAV. LAM. LAB. L.A. L. KIT. JST. JT. JAN. JOINT JOIST LOW/LINEN HOSE BIB HOLLOW CORE HARDWOOD HARDWARE HEIGHT HOLLOW METAL GALVANIZED IRON GLU-LAM BEAM GROUND GYPSUM HORIZONTAL INSULATION INTERIOR INVERT/INVERTED INSIDE DIAMETER/INTERIOR DESIGNER HDWR. I.D. HVAC INV. INT. INSUL. IN. HR. HORIZ. H.M. HT./HGT. HOUR INCH GYP. GR. GND. G.L.B. GL. G.I. HDWD. HD. H.C. H.B. H.HIGH HARD GLASS GRADE AREA DRAINA.D. B.W. BR. B. BOT. BM. BLK'G. BLK. BLDG. BITUM. BET. BD. AUTO. ASSY. ASB. ARCH. APPX. A.P. ANOD. ALT. AL. ADJ. ADH. BITUMINOUS BLOCKING BATH BEDROOM BACK OF WALK, BOT. OF WALL BOARD BETWEEN BUILDING BLOCK BEAM BOTTOM ADHESIVE ADJUSTABLE ALUMINUM ALTERNATE ANODIZED ACCESS PANEL APPROXIMATELY ARCHITECTURAL ASBESTOS ASSEMBLY AUTOMATIC PL LC ACOUS. A.C. A/C A.B. # ∅ @ & ANGLE CENTERLINE DIAMETER OR ROUND PERPENDICULAR POUND OR NUMBER PROPERTY LINE, PLATE ANCHOR BOLT AIR CONDITIONING ASPHALT CONCRETE ACOUSTICAL AT AND FINISH GRADE FLAT HEAD FIXTURE FLOW LINE FLASHING FLUORESCENT FACE OF CONCRETE/FACE OF CURB FACE OF FINISH FACE OF STUD/FACE OF STRUCTURE FACE OF MASONRY FIREPLACE FLOOR SINK FOOT OR FEET FOOTING FURRING FUTURE GALVANIZED GRAB BAR/GRADE BEAM GENERAL GROUND FAULT INTERRUPTG.F.I. GEN. G.B. GALV. GA. FUT. FURR. FTG. FT. F.S. FP. GAUGE F.O.M. F.O.S. F.O.F. F.O.C. FLUOR. FLR. FLASH. F.L. FIX./FIXT. FIN. F.H. F.G. FINISH FLOOR EQUIPMENT EXISTING EXHAUST EXPOSED EXTERIOR FIRE ALARM FLOOR CLEAN OUT FLOOR DRAIN FOUNDATION FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET EQPT./EQPM. F.E.C. F.E. FDN. F.D. F.C.O. F.A. F. EXT. EXPO. EXH. EXST. FIXED SOUTHS. SUPPLY AIR SOLID CORE SCHEDULE SECTION SHELF SHEET SHEATHING SIMILAR SOFFIT JOIST SERVICE SINK STATION STANDARD STEEL STORAGE STRUCTURAL SUSPENDED SYMMETRICAL STAINLESS STEEL SEAT COVER DISPENSER SUB DRAIN/SOAP DISPENSER S.S. SUSP. STRUCT. STOR. SYM. STL. STD. STA. S.SK. S.C.D. SHT'G. SCHED. S.D. S.J. SIM. SHT. SH. SEC. S.C. S.A. PLUMBING PLYWOOD POINT OF CONNECTION PROJECTION POINT RETURN AIR RADIUS ROOF DRAIN RECEPTACLE RECTANGULAR REFERENCE REFRIGERATOR ROOF DRAIN LEADER REGISTER REQUIRED RESILIENT' ROOM REDWOOD REINFORCEMENT ROUGH OPENING RETAIN(ING), RETURN RECT. REINF. RESIL. REQ'D. REFR./ R/F. RET. R.O. RWD. RM. REG. REF. R.D.L. RECPT. PROJ. PLYWD. PLUMB. R.D. RAD. R.A. PT. PR. PNT. PAIR MOUNTEDMTD. MULLION NORTH NATURAL NUMBER NOMINAL NOT TO SCALE OVER OVERALL OBSCURE OFFICE OPENING OPPOSITE PERIMETER PLATE/PROPERTY LINE PLASTER NOT IN CONTRACT NATURAL GRADE OVERFLOW DRAIN PLASTIC LAMINATE OUTSIDE DIAMETER (DIMENSION) O/. P.LAM. O.F.D. PERIM. OPNG. O.D. PLAS. PL. OPP. OFF. OBS. O.A. N.G. N.I.C. N.T.S. NOM. NO. NAT. N. MUL. MATERIAL MAXIMUM MECHANICAL MEMBRANE METAL MAN HOLE MINIMUM MIRROR MOSAIC MEDICINE CABINET MANUFACTURER MISCELLANEOUS MASONRY OPENING MAX. MEMB. MECH. M.O. MISC. MFR./MFGR. M.C. MOS. MIR. MIN. M.H. MET./MTL. MAT. TYPICALTYP. UNIFORM BULIDING CODE UNDERWRITER'S LABORATORY UNLESS NOTED OTHERWISE VENT THROUGH ROOF WEST, WIDE, WIDTH V.T.R. WP. W.I. W.C. W.H. W. WD. W/.WITH WOOD WATER HEATER WATER CLOSET WROUGHT IRON WATERPROOF U.N.O. U.L. U.B.C. VERT. VENT. UR. UNF. U.UNDER UNFINISHED URINAL VENTILATING VERTICAL TOP OF PAVING TOP OF STRUCTURE/SLAB TONGUE AND GROOVE TOP OF CURBT.C. T.&G. T.W. T.O.S. T.PL. T.P. TER. TEMP. TEL. T.CL. TRANS. THK.THICK TRANSFORMER TIME CLOCK TELEPHONE TEMPERED TERRAZZO TOP OF PLATE TOP OF WALL T.TREAD PAINT(ED) P.O.C. EQ.EQUAL / EQUIVALENT FIELD VERIFYF.V. (E.)EXISTING NEW(N.) VER.VERIFY FACTORYFAC. B.O.BY OWNER/BY OTHERS GENERAL CONTRACTORG.C. APPV'D.APPROVED BEL.BELOW ON CENTERO.C. ABV.ABOVE HDR.HEADER SELECTEDSEL. METAL BOLTM.B. PARALLEL STRAND LAMINATEPSL. ROOF RAFTERR.R. /CEILING JOIST FLOOR JOISTF.J. SIMPSONSIMP. T.S.TOP OF STEP UNDERGROUNDU.G. V.VERTICAL W.W.M.WELDED WIRE MESH EACH WAYE.W. DECO.DECORATIVE EXISTING GRADEE.G. GRADE PLANEG.P. 61. CONTRACTOR SHALL PREPARE AND MAINTAIN ALL CONSTRUCTION, AND SURROUNDING AREAS, FREE OF DEBRIS OR HAZARDOUS MATERIALS AT ALL TIMES. CONTRACTOR SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT DUST FROM RISING. 62. CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR AND/OR THE REPLACEMENT OF ANY ITEMS DAMAGED DURING CONSTRUCTION OR CLEAN-UP. ANY DAMAGE TO EXISTING STRUCTURES DURING THE CONSTRUCTION OR THE NEW WORK SHALL BE REPAIRED TO EQUIVALENT OR BETTER THAN ORIGINAL CONDITION AT CONTRACTOR'S EXPENSE. 63. CONSTRUCTION PERSONNEL SHALL BE CONFINED TO THE LIMITS OF THE CONSTRUCTION AREA. ALL OSHA REGULATIONS FOR CONSTRUCTION AREAS SHALL BE STRICTLY FOLLOWED. CONTRACTOR SHALL PROVIDE PROPER SAFEGUARDS DURING ALL PHASES OF CONSTRUCTION. 64. CONTRACTOR TO REMOVE, RELOCATE OR RE-ROUTE, AS NECESSARY, ELECTRICAL, TELEPHONE, WATER, SEWER, GAS OR ANY OTHER UTILITY LINES ENCOUNTERED AND SHALL COORDINATE THIS WORK WILL ALL LOCAL UTILITY COMPANIES. 65. CONTRACTOR SHALL PROVDE TEMPORARY WEATHER PROTECTION FOR PORTIONS OF THE WORK THAT BECOME EXPOSED TO WEATHER AND SHALL BE RESPONSIBLE FOR DAMAGE CAUSED BY INSUFFICIENT PROTECTION. 66. CONTRACTOR TO OBTAIN WRITTEN APPROVAL FROM OWNER AND ARCHITECT PRIOR TO ANY CHANGES OR DEVIATION FROM CONTRACT DOCUMENTS. 67. CONTRACTOR SHALL SUBMIT IN WRITING ALL PROPOSALS FOR ADDITIONAL WORK TO THE OWNER FOR REVIEW AND APPROVAL. NO WORK IS TO PROCEED UNTIL AN AUTHORIZATION TO PROCEED, SIGNED BY THE ARCHITECT & OWNER'S REPRESENTATIVE IS RETURNED TO THE GENERAL CONTRACTOR. 68. CONTRACTOR SHALL BE AWARE THAT SPECIFIC FIRE-RATED SEPARATION WITHIN THE BUILDING'S CONSTRCUTION ARE REQUIRED BY CODE. THE USE OF SPECIFIC MATERIALS AND COMBINATION OF MATERIALS WITHIN FIRE RATED ASSEMBLIES, AS CALLED FOR ON THE DRAWINGS AND SPECIFICATIONS, ARE FOR THE PURPOSE OF ACHIEVING THOSE REQUIRED FIRE SEPARATIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THAT ANY CHANGE IN MATERIAL THAT IS REQUESTED BY OR MADE BY THE CONTRACTOR AND/OR IT'S SUBCONTRACTORS, FROM THOSE MATERIALS DRAWN OR SPECIFIED, DOES NOT IN ANY WAY AFFECT OR LESSEN THE REQUIRED CONSTRUCTION ASSEMBLY. SPECIFIC SEQUENCES OR METHODS OF ACHIEVING FIRE RATED ASSEMBLIES REQUIRED BY A "U.L. NO." LISTING SHALL BE FOLLOWED WITHOUT DEVIATION, UNLESS OTHERWISE NOTED OR DETAILED. 69. CONTRACTOR TO FURNISH AND INSTALL ALL BLOCKING REQUIRED FOR WALL MOUNTED OR BRACED FIXTURES, MILLWORK, SHELVES, TOILET FIXTURES, AND ACCESSORIES OR 'BY OTHER' ITEMS DESCRIBED IN INTERIOR DESIGN AND ARCHITECTURAL DRAWINGS. BLOCKING SHALL BE CONSTRUCTED TO SUPPOR THE IMPOSED LOAD. 70. ALL MANUFACTURED ARTICLES, MATERIALS AND EQUIPMENT SHALL BE SUPPLIED, INSTALLED, CONNECTED, ERECTED, USED, CLEANED AND CONDITIONED AS DIRECTED BY THE MANUFACTURERS. 71. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY/COORDINATE UTILITY REQUIREMENTS FOR ALL OWNER/VENDOR FURNISHED EQUIPMENT, FIXTURES OR APPLIANCES. 72. CONTRACTOR SHALL PROVIDE ALL NECESSARY FASTENERS, SUPPORTS, SHIMMING, FLASH PATCHING, ETC. FOR THE PROPER INSTALLATION OF SUCH ITEMS AS DIRECTED BY THE MANUFACTURERS. 73. UPON COMPLETION OF THE PROJECT, THE CONTRACTOR SHALL GIVE TO THE OWNER A COMPLETE SET OF AS-BUILT CIVIL, LANDSCAPE, ARCHITECTURAL, MECHANICAL, PLUMBING ELECTRICAL AND FIRE PROTECTION DRAWINGS ALONG WITH THE WRITTEN GUARANTIES, OPERATION AND MAINTENANCE MANUALS OF ALL EQUIPMENT AND FINISHES INSTALLED. THE CONTRACTOR SHALL MAINTAIN A CURRENT SET OF AS-BUILT DRAWINGS AND SPECIFICATIONS. INFORMATION SHALL BE RECORDED BY CONTRACTOR AS CONSTRUCTION PROGRESSES AND REVIEWED FOR COMPLETENESS AT EACH REQUISITION REQUEST. 74. CONTRACTOR IS RESPONSIBLE TO THOROUGHLY VACUUM CLEAN ALL CARPETED ARES, CLEAN ALL FLOORING, MILLWORK, LIGHT FIXTURES, GLASS, ETC. AND UNCOVER AND VACUUM OUT ALL MECHANICAL UNITES AFTER THE WORK IS COMPLETED AND MAINTAIN CLEAN CONDITIONS THROUGH THE TENANT'S MOVE-IN. NO. REVISION DATE GENERAL NOTES CONTINUED ANTONY FANTICOLA & JOANN FANTICOLA 20 JOB NO.DATEDOCUMENT VALID UPONORIGINAL SIGNATURESHEET NO.REVISIONSOWNER INFORMATION:PROJECT NAMESTATUSThese documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECTT-1.206/22/181120-2018SUPPLEMENTAL NOTES & DOCUMENTS FANTICOLA RESIDENCEFANTICOLA RESIDENCE ANTONY & JOANN FANTICOLA 1120 W. OCEAN FRONT NEWPORT BEACH, CA 92661 CDP1120 W. OCEANFRONT NEWPORT BEACH, CA 92661CAITLIN SMITHCAL GREEN - RESIDENTIAL MANDATORY MEASURESRESIDENTIAL CONSTRUCTION MINIMUM REQUIREMENTS213NO. REVISION DATE21 22 S.Y.S.B.3' - 0"F.Y.S.B. 9' - 0"S.Y.S.B.3' - 0"P.L. TO ALLEY C.L. 9' - 11 5/8" F.Y.S.B. 9' - 0"F.O.F.5' - 2 1/4"F.O.F.2' - 8 1/8"F.O.F.2' - 8 1/4"F.O.F.3' - 2 7/8"F.O.F.3' - 2 3/4"F.O.F.2' - 11 7/8"F.O.F.3' - 0 1/4"F.O.F.2' - 9 5/8"F.O.F.3' - 1 1/8"N72°31'26"W 36.40'GREAT ROOM LOUNGE KITCHEN DINING STAIRS PWDR. PANTRY MUD ROOM ELEV. FOYER 3-CAR GARAGE OCEAN FRONTALLEY3' - 2"F.O.F.3' - 1"F.O.F.3' - 0"3' - 2"F.O.F.3' - 1"3' - 2"F.O.F. 14' - 0" 14' - 1"F.O.F.2' - 0"2' - 2"F.O.F.3' - 0"3' - 1"F.O.F.3' - 8 5/8"3' - 10 5/8"F.O.F.4' - 6"4' - 7"F.O.F. 7' - 5" 7' - 7"S.Y.S.B.3' - 0"S.Y.S.B.3' - 0"1 1 1 111 1 1 2 2 3 3 333 CLR.28' - 3"CLR. 20' - 0" CLR. 21' - 10" 4 5 6 14.98' (N.) T.W. 14.98' (N.) T.W. 14.98' (N.) T.W. 14.98' (N.) T.W. P.L. TO STREET C.L. 12' - 4" 7 7 8 5 9 9 10 11 10 12 12 13 13 14 14 N73°31'57W 36.39'N17°30'37W 102.51' N17°30'25W 102.52' 15 16 17 17 CLR. 3' - 0" 18 (E.) 12.0 FS (E.) 12.03 FS (E.) 12.84 FS (E.) 12.02 FS 19 20 2121 2121 21 21 21 21 21 PATIO FIRE PIT PATIO 2222 22 22 22 22 22 22 22 22 2222 22 11 UP UP 12.32' T.O.S. 12.32' T.O.S.23UP EXISITING STRUCTURE (NOT A PART) EXISITING STRUCTURE (NOT A PART) 14.98' (N.) T.W. (E.) 12.06 FS 24 25 14.63' (N.) T.W. (E.) 12.04 FS 20 26 STEP PER CIVIL STEP PER CIVIL F.O.F.8' - 6"8' - 7"STEP PER CIVIL TRASH 27 17.06' T.W.17.06' T.W.17.06' T.W. 17.06' T.W. 17.06' T.W.17.06' T.W. (E.) 12.10 FS (E.) 11.66 FS (E.) 11.08 FS CLR.4' - 10 1/2"CLR. 4' - 10 3/4" 12.32' T.O.S. SLOPE PER CIVIL 28 28 (E.) 11.16 FS (E.) 11.63 FS(E.) 12.72 FS CLR.3' - 2 3/8"29 29 STEP REF. CIVIL DWGS. 5 CLR.28' - 3"8' - 8"2' - 2"11"RECESSED ELEC. PANEL3' - 0"30 31 31 32 32 32 33 7 R @ 0' - 6 1/8"2 R @ 0' - 7 1/4"16 R @ 0' - 6 1/8"2 R @ 0' - 6 1/8"2 33 34 34 19 19 19CLR.2' - 6"35 35 35 35 35 JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONSOWNER INFORMATION:PROJECT NAME STATUS These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT A-0.0 06/22/18 1120-2018ARCHITECTURAL SITE PLANFANTICOLA RESIDENCE FANTICOLARESIDENCEANTONY & JOANNFANTICOLA1120 W. OCEAN FRONTNEWPORT BEACH, CA92661CDP 1120 W. OCEANFRONTNEWPORT BEACH, CA 92661CAITLIN SMITH JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONSOWNER INFORMATION:PROJECT NAME STATUS These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT A-0.0 06/22/18 1120-2018ARCHITECTURAL SITE PLANFANTICOLA RESIDENCE FANTICOLARESIDENCEANTONY & JOANNFANTICOLA1120 W. OCEAN FRONTNEWPORT BEACH, CA92661CDP 1120 W. OCEANFRONTNEWPORT BEACH, CA 92661CAITLIN SMITH KEYNOTE LEGEND 1 PROPERTY LINE 2 FRONT YARD SETBACK 3 SIDE YARD SETBACK 4 INTERIOR STAIRS/STEPS - REF. PLANS 5 STEP IN FOUNDATION - REF. CIVIL DWGS. 6 RESIDENTIAL ELEVATOR - 'ROCKY MOUNTAIN' OR EQUIV., SHAFT SIZE = 60" X 60" CLEAR - PROVIDE SHOP DWGS. TO ARCH. PRIOR TO PURCHASE & INSTALLATION 7 EXPOSED STRUCTURAL STEEL COLUMN, SIZE PER STRUCT.; PAINT & SEAL AS SEL. (ARCH. TO APPV.) 8 FIREPLACE - PREFABRICATED, WOOD BURNING, 'HEATILATOR' BIRMINGHAM 42" STLYE "BIR42" [DTL. 22/AD-1] (FACTORY BUILT FIREPLACES, CHIMNEYS, AND ALL OTHER COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING AND MFG'R. INSTALLATION INSTRUCTIONS. FIREPLACE MUST COMPLY W/. THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES.) 9 CABLE TV JUNCTION BOX 10 (E.) WATER METER LOCATION (REF. SURVEY & CIVIL DWGS.) 11 (E.) ELECTRICAL PULL BOX, REF. SURVEY 12 (E.) GAS METER LOCATION (REF. SURVEY & CIVIL DWGS.) 13 CENTERLINE OF ALLEY 14 CENTERLINE OF STREET 15 PROVIDE GAS STUB-OUT FOR EXTERIOR FIREPIT 16 CUSTOM ENTRY GATE - WD. - G.C. TO PROVIDE SHOP DWGS. FOR ARCH. APPROVAL 17 (N.) CUSTOM WOOD GATE - PER OWNER, STAIN & SEAL, ARCH TO APPRV. (MAX. 6' HT. ABOVE NATURAL GRADE) 18 MAIN SERVICE PANEL, 400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION) 19 (N.) PROPERTY LINE WALL- CMU WITH STUCCO FINISH - MAX. 6' ABV. N.G. PER C.N.B. - OPEN FENCING ALLOWED ABV. WALL 9' MAX ABV. N.G. OR 6' ABV. FINISH FLOOR HEIGHT WHICHEVER IS LESS 20 (N.) SITE CUSTOM WOOD FENCE - PER OWNER, STAIN & SEAL, ARCH TO APPRV. 21 EXISTING STRUCTURE - NOT A PART 22 OUTLINE OF EXISTING STRUCTURE TO BE REMOVED 23 VEHICLE - MINIMUM PARKING DIMENSIONS ON PLANS 24 DOWNSPOUT - KYNAR FINISH TO MATCH METAL ROOFING, SHAPE AS SEL. (ARCH. TO APPROVE) 25 EXISTING PROPERTY LINE WALL - TO BE REMOVED 26 EXTERIOR COMBUSTION AIR DUCTS SHALL BE LISTED COMPONENTS OF THE FIREPLACE, AND INSTALLED ACCORDING TO THE F.P. MFGR'S. INSTR'S. (CRC R1005) 27 TRASH LOCATION - SCREEN FROM STREET AS NEEDED 28 WATER HEATER - TANK - SIZE PER T-24 REPORT REF. DTL. 1/AD-1 29 HOSE BIB - RECESSED BRASS, VERIFY LOC'N. & FIXTURE W/. OWNER 30 MOVEABLE BBQ UNIT - COORDINATE W/. OWNER - PROVIDE POWER & GAS AS REQ'D. BY MFG'R. 31 PROVIDE GAS STUB-OUT PER OWNER, ARCH. TO APPROVE 32 (E.) PLANTER TO BE REMOVED. 33 (E.) PROPERTY LINE WALL TO REMAIN - PROTECT IN PLACE 34 (N.) PROPERTY LINE WALL- CMU WITH STUCCO FINISH - MAX. 42' ABV. N.G. PER C.N.B. 35 HARDSCAPE - COLORED & SCORED CONCRETE (AS SELECTED) TRUE NORTH DIMENSION NOTE: ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE NEAREST 1/8" - CONTACT ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS. 1/4" = 1'-0"1 ARCHITECTURAL SITE PLAN PROJECT NORTH LANDSCAPE NOTES: 1. ENCOARCHMENT PERMIT REQ'D. FOR ANY WORK PROPOSED IN THE PUBLIC R.O.W. 2. IF APPLICABLE, REF. PRELIMINARY LANSCAPE PLAN, FOR ALL HARDSCAPE & PLANTING AREAS WITH REPECTIVE HEIGHTS AND MATERIALS. GENERAL NOTE: SEE SHEET A-3.0 FOR ROOF PLAN INFORMATION NOT SHOWN ON THIS SHEET (INCLUDING EAVE DETAILS AND PROJECTION DISTANCES). C.N.B. NOTES: 1. ISSUANCE OF A BUILDING PERMIT BY THE CITY OF NEWPORT BEACH DOES NOT RELIEVE APPLICANTS OF THE LEGAL REQUIREMENTS TO OBSERVE COVENANTS, CONDITIONS AND RESTRICTIONS WHICH MAY BE RECORDED AGAINST THE PROPERTY OR TO OBTAIN PLANS YOU SHOULD CONTACT YOUR COMMUNITY ASSOCIATIONS PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION AUTHORIZED BY THIS PERMIT. 2. PRIOR TO PERFORMING ANY WORK IN THE CITY RIGHT-OF-WAY AN ENCROACHMENT PERMIT MUST BE OBTAINED FROM THE PUBLIC WORKS DEPARTMENT. 3. A CAL-OSHA PERMIT IS REQUIRED FOR EXCAVATIONS DEEPER THAN 5' AND FOR SHORING AND UNDERPINNING. NO. REVISION DATENO. REVISION DATE WALL NOT TO BE FULL HT 23 24 25 UP UP LOT 19 PARCEL 1 PMB 260/15-16 LOT 17 OCEAN FRONTEL=12.04EL=12.06EL=12.0511.411.3 11 .311.1 11.1011.0511.0211.0311.2911.1610.8110.7810.7810.7910.7310.6610.8510.8311.08 11.0510.2210.2110.1510.1310.0910.8610.7210.8910.6410.7310.5610.5710.4710.7410.6310.5710.63 10 .9 9 10.8810 .8 6 10.6910 .9 911.8311.8311.8611.8311.9812.0512.0712.0712.0312.0412.08 12.09 11 .8 6 1 1 .7 0 1 1 .4 7 11 .0 6 11.0210.9611.33 1 1 .4 2 11.6 2 11.7 7 11.8 9 11.6612.1011.0311.3112 .2 312.3412.61 2 .3 912.4712.6012.641 3 .413.1 11.9 12.112.01 2 .0 1 12.03 12.0212.0312.0312.0312.02 12.06 12 .0 3 1 1 .7 0 12.0712.0412.06 12.7212.8411.4411.2111.14 12.9612.9613.0312.9612.49 12.1111.6311.971 2 .4 6 13.0912.7712.8611.4611.1011.1212.7012.6912.7012.6812 .6 91 2.7111.1511.1411.37 1 1 .1 3 11.1 11.1111.11 1 0 .9 2 11 .1 611.0911 .1 0 11.1611.1611.1611.1811.1311.0911.0811.0211.1211.1111.0811.1 1 11 .011.1411.1211.13 11.121 1 .7 0 11.6711.6612.16 12.1512.20 11.1 11.210.91 9 .1 6 T o p o f a r c h 10 .9 11.10Existing building Existing building W ater m eterSewer cleanoutFd. lead and hole, no tagFd. lead and hole, no tag14.24 T.W .17.16 T.W .11.30 G .F.F.10.89 G .F.F.11.13 G .F.F.10.89 G .F.F.10.73 G .F.F.10.70 G .F.F.10.76 G .F.F.EL=11.9517.06 T.W.17.06 T.W.17.74 T.W.14.42 T.W .13.40 T.W .14.43 T.W .15.03 T.W .14.45 T.W. 13.13 T.W.13.06 T.W .15.05 T.W .1 4 .4 3 T .W .15.12 T.W.1 3 .4 5 T .W .1 5 .2 0 T .W .1 7 .7 2 T .W .12.73 Threshold35.27 Roof ridge37.84 Roof ridge2 2 .70 D e c k 15.05 T.W .15.04 T.W.17.15 T.W.15.06 T.W .15.15 T.W.11.39 Threshold17.17 T.W .13.22 Threshold10.84 Threshold15.86 T.W .1 2 .5 5 T .W .11.21 Threshold1 5 .8 8 T .W .1 2 .6 2 T .W .12.78 Threshold11.67 T.W .PT#4 - 11.28 PT# 2 - 11.08 F.S. PT #3 - 12.83 INT PT# 1 - 12.03 FS 6' - 11 7/8" 3' - 10 7/8"7' - 9"5' - 3"JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONSOWNER INFORMATION:PROJECT NAME STATUS These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT A-0.3 06/22/18 1120-2018GRADE PLANE EXHIBITFANTICOLA RESIDENCE FANTICOLARESIDENCEANTONY & JOANNFANTICOLA1120 W. OCEAN FRONTNEWPORT BEACH, CA92661CDP 1120 W. OCEANFRONTNEWPORT BEACH, CA 92661CAITLIN SMITH NO. REVISION DATE 3/16" = 1'-0"1 GRADE PLANE EXHIBIT 12.03 F.S. 11.08 F.S. 12.83 INT 11.28 F.S. 47.22 / 4 = 11.81 26 DW T UP DW647 SF 3-CAR GARAGE 1728 SF FIRST FLOOR 151 SF PORCH 40 SF ENTRY 7' - 2"5' - 7"5' - 0" 226 SF OPEN #1 22' - 11 1/4"12' - 11 3/4"11' - 8"5' - 1 3/8"41' - 1 1/4"9' - 7 5/8"7' - 8"1' - 10"20' - 7 1/4"30' - 1 7/8"28' - 7 7/8"24' - 7 7/8"12' - 11 3/4"22' - 5 1/4" A B C D E F G 2394 SF SECOND FLOOR153 SF MA. BALCONY 41' - 1 1/4"9' - 1 1/8"4' - 9"28' - 10 1/4"30' - 1 7/8"18' - 3 5/8"30' - 1 7/8"7' - 8 1/4"5' - 0 1/2"17' - 5 1/8"28' - 10 1/4" 23' - 10 1/4"A B C D E F 400 SF THIRD FLOOR 648 SF DECK 2 1111 SF DECK 1 A B C D 5' - 4 1/4"5' - 0"5' - 7 3/4"7' - 7 1/4"9' - 10 3/4" 21' - 10" 22' - 1 3/4" 16' - 6 1/2" JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONSOWNER INFORMATION:PROJECT NAME STATUS These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT A-0.4 06/22/18 1120-2018BUILDING AREA PLANSFANTICOLA RESIDENCE FANTICOLARESIDENCEANTONY & JOANNFANTICOLA1120 W. OCEAN FRONTNEWPORT BEACH, CA92661CDP 1120 W. OCEANFRONTNEWPORT BEACH, CA 92661CAITLIN SMITH BUILDING AREA SCHEDULE NAME AREA COMMENTS FIRST FLOOR 1728 SF SECOND FLOOR 2394 SF THIRD FLOOR 400 SF 4523 SF 3-CAR GARAGE 647 SF 647 SF GRAND TOTAL 5169 SF OUTDOOR AREA SCHEDULE NAME AREA COMMENTS DECK 2 648 SF DECK 1 1111 SF MA. BALCONY 153 SF OPEN SPACE PORCH 151 SF OPEN SPACE ENTRY 40 SF OPEN SPACE OPEN #1 226 SF OPEN SPACE GRAND TOTAL 2329 SF LOT INFORMATION: NO. REVISION DATE LANDSCAPE AREA SCHEDULE NAME AREA COMMENTS 1/8" = 1'-0"1 FIRST FLOOR (T.O.S.) 1/8" = 1'-0"2 SECOND FLOOR T.O.S. (TYP.) 1/8" = 1'-0"3 THIRD FLOOR T.O.S. (TYP.) FLOOR PLAN A B C D 41' - 1 1/4" X 30' - 1 7/8 " = 1239.55 S.F.. 9' - 7 5/8" X 28' - 7 7/8 = 276.11 S.F. 7' - 8" X 24' - 7 7/8"= 189.03 S.F. 1' - 10" X 12' - 11 3/4"= 23.80 S.F. TOTAL: 1721.30 S.F. E F G 22' - 11 1/4" X 5' - 1 3/8" = 117.32 S.F. 22' - 5 1/4" X 11' - 8"= 261.77 S.F. 20' - 7 1/4" X 12' - 11 3/4"= 267.42 S.F. TOTAL: 646.51 SF GRAGE FLOOR PLAN A B C D 41' - 1 1/4" X 30' - 1 7/8 " = 1,239.55 S.F. 9' - 1 1/8" X 18' - 3 5/8 = 166.43 S.F. 4' - 9" X 30' - 1 7/8"= 143.64 S.F. 28' - 10 1/4" X 17' - 5 1/8"= 502.84 S.F. TOTAL: 2394.14 SF E F 23' - 10 1/4" X 5' - 0 1/2 = 120.26 S.F. 28' - 10 1/4" X 7' - 8 1/4"= 221.82 S.F. FLOOR PLAN A B C D 9' - 10 3/4" X 7' - 7 1/4 " = 75.25 S.F. 22' - 1 3/4" X 5' - 7 3/4 = 125.03 S.F. 16' - 6 1/2" X 5' - 0"= 82.71 S.F. 21' - 10" X 5' - 4 1/4"= 116.90 S.F. TOTAL: 399.89 SF ZONED: R-1 SITE AREA:3,731.73 S.F. BUILDABLE AREA: 2,843.13 S.F. TOTAL ALLOWABLE AREA: 2 x 2,843.13 S.F. = 5,686.26 S.F. REQ'D. OPEN VOLUME = 2,843.13 X .15 = 426.47 MAX. THIRD FLR. ALLOWABLE = 2,843.13 X .2 = 568.63 OPEN VOLUME PROVIDED = 567 27 JOB NO.DATEDOCUMENT VALID UPONORIGINAL SIGNATURESHEET NO.REVISIONSOWNER INFORMATION:PROJECT NAMESTATUSThese documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECTA-1.006/22/181120-20183-DIMENSIONAL VIEWS FANTICOLA RESIDENCEFANTICOLA RESIDENCE ANTONY & JOANN FANTICOLA 1120 W. OCEAN FRONT NEWPORT BEACH, CA 92661 CDP1120 W. OCEANFRONT NEWPORT BEACH, CA 92661CAITLIN SMITHNO. REVISION DATE3AXONOMETRIC - NORTHEAST4AXONOMETRIC - SOUTHEAST2AXONOMETRIC - SOUTHWEST1AXONOMETRIC - NORTHWEST28 DW T UP DWPLAN LEGEND NEW WALL - 2 x 6 STUDS @ 16" O.C. NEW WALL - 2 x 4 STUDS @ 16" O.C. WALL W/. STONE VENEER - 2x STUDS @ 16" O.C. CONCRETE WALL - REF. STRUCT. DOUBLE WALL CONSTRUCTION - 2 x 4 MIN. STAGGERED STUD @ 16" O.C. WINDOW - REFERENCE SCHEDULE DOOR - REFERENCE SCHEDULE CABINET - BUILT IN CASEWORK COLUMN - WOOD, STEEL, REF. STRUCTURAL DWGS. FURNITURE - FOR PRESENTATION PURPOSES ONLY FIREPLACE - PREFAB GAS-ONLY APPLIANCE PLUMBING FIXTURE - SINK (AS SELECTED) PLUMBING FIXTURE - TOILET (AS SELECTED) LIGHTING FIXTURE - REFERENCE ELECTRICAL PLANS FIRE RATED CEILING ASS'Y. REF. DTL. 7/AD-1 INT. FIRE RATED PARTITION REF. DTL. 7/AD-1 101 1i ?KEYNOTE TAG - REFERENCE KEYNOTE LEGEND THIS SHT. WINDOW TAG - REFERENCE SHEET A-7.0 DOOR TAG - REFERENCE SHEET A-7.0 EXT. FIRE RATED PARTITION REF. DTL. 5/AD-1 EXISITING WALL TO REMAIN - 2 x 6 STUDS EXISITING WALL TO REMAIN - 2 x 4 STUDS CONCRETE MASONRY WALL - 6" CMU U.N.O. EXISITING WALL TO BE REMOVED AREA OF ADDITION WINDOW WALL TAG - REFERENCE SHEET A-7.01i 1.PROVIDE WHOLE BUILDING MECHANICAL VENTILATION PER ASHRAE STANDARD 62.2-2016 SECTION 4, WITH EXCEPTION THAT NATURAL VENTILATION THROUGH DOORS AND WINDOWS IS NOT AN ACCEPTABLE ALTERNATIVE TO WHOLE-BUILDING VENTILATION (BEES 152(a), EXCEPTION 5 TO SECTION 152 (a)). FOR CONTINUOUS WHOLE-BUILDING VENTILATION, MIN. REQUIRED RATE OF VENTILATION IS 1 CFM FOR EACH 100 S.F. OF CONDITIONED FLOOR AREA PLUS 7.5 CFM FOR EACH OCCUPANT (ONE OCCUPANT PER BEDROOM +1). VENTILATION TO BE PROVIDED BY EXHAUST AIR, SUPPLY AIR OR COMBINED EXHAUST AND SUPPLY AIR. 2.PROVIDE IN KITCHEN LOCAL EXHAUST SYSTEM VENTED TO OUTDOORS WITH RATE = 100 CFM (PART OF WHOLE-BUILDING VENTILATION REQUIREMENT). MECHANICAL VENTILATION NOTE: CALCULATIONS: UNIT: 4,523 S.F. (0.01)4,523 S.F.+ [7.5 CFM x OCC. (BED. +1)] = 45.23 CFM + (7.5 x 4) = 75.23 CFM REQ'D. A-4.02 A-4.1 A-4.0 A-4.1 1 1 2 2 A-5.0 2 A-5.0 1 A-5.0 1 A-5.0 6' - 11" CLR. 4' - 10 3/4" 3 A-5.1 3 A-5.1 GREAT ROOM LOUNGE DINING KITCHEN PWDR. PANTRY 3-CAR GARAGE FOYER MUD ROOMCLOSET 2 A-5.1 2 A-5.1 1 A-5.1 1 A-5.1 CLR.4' - 10 3/4"4 A-5.0 4 A-5.0 F.Y.S.B. 9' - 0"S.Y.S.B.3' - 0"14' - 1"80' - 10 1/4"7' - 7" 41' - 1 1/4"9' - 7 5/8"7' - 2"22' - 11 1/4" 4' - 6 5/8"5' - 1 1/8"4"6' - 6"4"4' - 9 1/8"18' - 2 1/8" 8 3/8"5' - 8 1/2"2"8' - 8"6' - 2 1/8"2' - 9 1/8"13' - 3 1/8"2' - 3 5/8"1' - 4 3/8"3' - 0"30' - 2 7/8"3' - 2"7 7/8"29' - 7 7/8"14' - 1"80' - 10 1/4"7' - 7" 8 3/8"5' - 8 1/2"15' - 0 1/8" 1 1 1 1 2 4 3 5 3 4 5 7 7 8 2 2 3 11"1' - 6"4' - 0"4' - 7"4' - 8 3/8"CLR. 20' - 0"CLR.28' - 3"CLR. 21' - 10" 4 9 11 13 12 10 STAIRS 6 7 7 8 9 10 1112 13 1415 16 17 1891219 12 919 20 21 22 UP23 6 24 ELEV. 25 26 FD FLOOR DRAIN 12 9 27 28 28 28 12.32' T.O.S.12.32' T.O.S. 32 32 32 SLOPE PER CIVIL 33 CLR. 4' - 1" CLR. 4' - 0 7/8"TYP.11"CLR.4' - 0"CLR. 4' - 0 7/8" TYP. 11" CLR. 4' - 1"CLR.4' - 0"TYP.11"34 2' - 9 1/8" 6 21' - 5"18' - 3 7/8"8' - 0 3/8"12' - 0 1/4"21' - 0 3/4" 8' - 0 3/8" 1' - 4 1/8" 1' - 0 5/8"2' - 4 7/8"7' - 2 5/8"2' - 10 5/8"18' - 2 1/8"1' - 8 1/8"9' - 9 7/8"16' - 2 1/8"1' - 8 1/8"3' - 10 5/8"29' - 4 1/4"3' - 2"NOTE: PROVIDED MIN. 5/8" TYP. X GYPSUM BOARD ON ALL WALLS STEP PER CIVIL STEP PER CIVIL 39 39 3' - 2"2' - 11 5/8"2' - 6"1' - 4 3/4"6' - 4 3/4"5' - 4 3/4"3' - 2"2' - 6 5/8"4' - 3 5/8"4' - 1 5/8"1' - 10 5/8"3' - 0 1/8"2' - 5 3/8"10 7/8"3' - 2"5' - 2 1/8"2' - 0 5/8"5' - 5 1/2"3' - 1 3/8"8' - 10 1/8"4' - 8 3/8"3' - 10 5/8"2' - 6 5/8"7' - 9 1/8"4' - 8"3' - 3 1/2"CLR.30" MIN.9 122' - 0"9' - 6"9" 1' - 0 3/8" 4 AD-1 8 6 AD-1 6 AD-1 7 AD-1 8 AD-1 8 AD-1 40 4040 40 40 40 41 43 43 7 4444 4444 45 32 32 R @ 0' - 6 1/8"2 R @ 0' - 6 1/8"2 44 1 A-5.2 1 A-5.2 12 2 49 48 49 48 49 484948 R @ 0' - 7 1/4"16 A-4.02 A-4.1 A-4.0 A-4.1 1 1 2 ELEV. 2 A-5.0 2 A-5.0 1 A-5.0 1 A-5.0 3 A-5.1 3 A-5.1 MASTER RETREAT MASTER SUITE MASTER W.I.C. LAUNDRY BATH #2 W.I.C. BEDROOM #2 BEDROOM #3W.I.C. BATH #3 BATH #4 DEN 2 A-5.1 2 A-5.1 1 A-5.1 1 A-5.1 BALCONY ENCROACHMENT 36" MAX MIN. 30" CLR. MIN. 30" CLR. 4 A-5.0 4 A-5.0STEP UP15 16 3 9 10 11 12 13 14 4 5 17 18 6 71516171819202122 F.Y.S.B. 9' - 0" 14' - 1"83' - 9 3/4"4' - 7 1/2" 41' - 1 1/4"9' - 1 1/8"33' - 7 1/4" 10 3/8"5' - 6 1/2"2"8' - 8"2"2' - 0 1/8"9' - 7"7' - 0 1/2"5' - 0 1/8"2' - 0 5/8"4' - 6 5/8"4' - 6 5/8"5' - 0 1/2"4' - 6 1/2"2' - 0 1/8"7' - 7 7/8"2' - 1 1/8"8' - 5 3/8"3' - 9 7/8"3' - 1"30' - 1 7/8"3' - 2"6 7/8"29' - 0"6 7/8"14' - 1"83' - 9 3/4"4' - 7 1/2" 3' - 6 3/8"11' - 2"2' - 6 1/8"19' - 1 5/8"3' - 4 3/4"2' - 4 7/8"8' - 0"2' - 1 3/8"4' - 10 1/2"3' - 7 3/4"1' - 10 1/8"6' - 9 7/8"2' - 1 1/8"8' - 5 3/8"3' - 9 3/4" 5 3' - 1"30' - 1 7/8"3' - 2"3' - 4 1/2"8 1/8"8' - 0"2' - 10 5/8"3' - 2 1/8"0"8' - 7 5/8"3' - 5"UPDN. MASTER BATH W/C. STAIRS MASTER BALCONY 27 25 28 29 23 24 30 35 34 33 32 36 19 20 21 22 31 23 29 6 12 9 19 30 SEAT SHOWER 20 891227 19 9 12 26 25 19 CLR. 4' - 10 3/4"CLR.4' - 11 1/4"30 20 SEATSEATSHOWERSHOWER 8 9 12 20 89 12 306 SEAT SHOWER 20 6 8 12 9 12 6 31 3 7 30 22.40' T.O.S. 21.90' T.O.S. 21.90' T.O.S. 32 32 32 21.90' T.O.S. CLR. 4' - 1"TYP.11"CLR.4' - 2 1/4"CLR. 4' - 0 3/4"CLR.4' - 0"TYP. 11" CLR. 4' - 1 1/8"CLR.4' - 2 1/4"CLR. 4' - 0 7/8"TYP.11"26 MIN. ø 30" 6' - 2"CLR.3' - 0 3/4"MIN. ø 30" MIN. ø 30" 35 36 36 36 MIN. ø 30" CLR. 30" MIN.CLR.3' - 1 3/4"CLR.4' - 3 3/8"24 37 37 37 37 38 38 38 38 29 3' - 2"12' - 8 3/4"4' - 4 7/8"13' - 0 1/4"3' - 1"1' - 6 1/4"11"2' - 2"2' - 6 1/4"2' - 11 3/4"5' - 0 1/8"2' - 2 5/8"7' - 6 3/4"5' - 7 7/8"9' - 11 5/8"9' - 7 5/8"4' - 8 1/8"4' - 10 3/8"3' - 8 3/4"5' - 11 1/4"2' - 2 1/8"2' - 6 5/8"8' - 6"1' - 1 1/2"4' - 4 7/8"11' - 6 1/4"1' - 6"3' - 1"4' - 4 7/8"8' - 9"3' - 11 3/4"3' - 2"4' - 9 1/4"1' - 9 1/4"2' - 2 1/8"4' - 3 5/8"2' - 0"4' - 4 7/8"2' - 2"3' - 1"4' - 5 5/8"1' - 11 1/8"1' - 7 5/8"4' - 11 7/8"2' - 4 3/4"2' - 10 1/8"2' - 5 3/8"3' - 6 3/4"10"5' - 1 1/4"2' - 2 1/8"2' - 6 5/8"3' - 11 3/8"2' - 9 1/8"1' - 7 5/8"4' - 4 5/8"3' - 2"2' - 2"4' - 6 1/2"7' - 8 1/4" 17' - 2 1/2"22' - 6 3/8"12' - 6 3/8"8' - 6 1/4"8' - 8"14' - 4 1/4"15' - 2 5/8"14' - 11 1/8"15' - 0 7/8"15' - 0 7/8"2%2%2%2%4 AD-1 9 AD-1 2%2%2%2%PIVOT42 3' - 3 3/8"1 A-5.2 1 A-5.2 36 46 AD-1 11 AD-1 11 AD-1 11 AD-1 11 47 48 48 47 47 48 47 48 SHOE LINEN LINEN 48494849 48 49 49 48 49 48 49 48 4849 R @ 0' - 7 1/4"16 R @ 0' - 7 1/4"16 JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONSOWNER INFORMATION:PROJECT NAME STATUS These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT A-2.0 06/22/18 1120-2018FLOOR PLANFANTICOLA RESIDENCE FANTICOLARESIDENCEANTONY & JOANNFANTICOLA1120 W. OCEAN FRONTNEWPORT BEACH, CA92661CDP 1120 W. OCEANFRONTNEWPORT BEACH, CA 92661CAITLIN SMITH STAIRWAY NOTE: ALL STAIRWAYS SHALL HAVE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT CANDLE PER CRC R303.7 KEYNOTE LEGEND 1 MAIN SERVICE PANEL, 400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION) 2 FIREPLACE - PREFABRICATED, WOOD BURNING, 'HEATILATOR' BIRMINGHAM 42" STLYE "BIR42" [DTL. 22/AD-1] (FACTORY BUILT FIREPLACES, CHIMNEYS, AND ALL OTHER COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING AND MFG'R. INSTALLATION INSTRUCTIONS. FIREPLACE MUST COMPLY W/. THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES.) 3 EXTERIOR COMBUSTION AIR DUCTS SHALL BE LISTED COMPONENTS OF THE FIREPLACE, AND INSTALLED ACCORDING TO THE F.P. MFGR'S. INSTR'S. (CRC R1005) 4 VEHICLE - MINIMUM PARKING DIMENSIONS ON PLANS 5 DOWNSPOUT - KYNAR FINISH TO MATCH METAL ROOFING, SHAPE AS SEL. (ARCH. TO APPROVE) 6 FURNISHINGS - AS SELECTED 7 EXPOSED STRUCTURAL STEEL COLUMN, SIZE PER STRUCT.; PAINT & SEAL AS SEL. (ARCH. TO APPV.) 8 SINK - AS SELECTED (VERIFY COUNTER OR WALL MOUNT FIXTURES W/. OWNER) 9 BASE CABINET - BUILT-IN, FINISH AS SEL. 10 PROVIDE POWER FOR BUILT-IN APPLIANCE/EQUIPMENT 11 WINE RACKS - AS SELECTED - PROVIDE POWER 12 COUNTERTOP - AS SELECTED 13 CUSTOM BUILT DINING TABLE & KITCHEN ISLAND PER OWNER & ARCH. 14 KITCHEN SINK - AS SELECTED 15 DISHWASHER - AS SELECTED 16 TRASH COMPACTOR - VERIFY APPLIANCE W/. OWNER 17 RANGE - VERIFY APPLIANCE W/. OWNER - PROVIDE HOOD CAPABLE OF 100 CFM MIN. (VERIFY W/. MFGR.) 18 KITCHEN EXHAUST HOOD - PROVIDE MIN. RATE OF 100 CFM - INSTALL & PROVIDE POWER PER MFGR'S. INSTRS. - VENT. TO EXT. 19 UPPER CABINET - BUILT-IN, FINISH AS SEL. 20 TOILET - MIN. 24" CLR. IN FRONT, MIN. 30" CLR. WIDTH, REF. CAL GREEN NOTES FOR FLOW RATE INFO. 21 FREEZER - VERIFY APPLIANCE W/. OWNER 22 REFRIGERATOR - VERIFY APPLIANCE W/. OWNER 23 STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT CANDLE (CBC 1205.4) REF. DTL. 3/AD-1 24 RESIDENTIAL ELEVATOR - 'ROCKY MOUNTAIN' OR EQUIV., SHAFT SIZE = 60" X 60" CLEAR - PROVIDE SHOP DWGS. TO ARCH. PRIOR TO PURCHASE & INSTALLATION 25 WASHER - PROVIDE HOOK-UPS & POWER 26 DRYER - DRYER VENT 14' MAX. LENGTH (CMC 504.3.2) PROVIDE GAS STUB-OUT & POWER 27 LAUNDRY SINK - AS SEL. 28 1-3/8" MIN. SOLID CORE DOOR, SELF CLOSING & SELF LATCHING (R302.5.1) 29 EXTERIOR GLASS GUARDRAIL TO BE ACID-ETCHED WITH 'AVIPROTEK T' BY WALKER TEXTURES OR SIMILAR PRODUCT TO REDUCE POSSIBLE BIRD STRIKES - MIN. 42" HEIGHT - 4" MAX. SPHERE OPENING, REF. DTLS. 4, 13 & 14/AD-1 30 SHELF AND POLE - BUILT IN, FINISH AS SEL. 31 32 OUTLINE OF EXISTING STRUCTURE TO BE REMOVED 33 HANDRAIL - 34" - 38" ABOVE STAIR NOSING (36" TYP. U.N.O.) - MATERIAL AS SELECTED, REF. DTL. 2/AD-1 34 1-1/2" MAX. STEP AT OUTSWING DOORS (R311.3.1) 35 FAU - PROVIDE GAS S.O., POWER, AND VENTING AS REQ'D. BY MFGR. 36 WINDOW TO MEET EGRESS REQ'TS. - REF. WINDOW NOTE #4 ON SCHEDULE 37 TEMPERED GLASS ENCLOSURE - 1/2" THK. (MIN. 3/8" THK.) GLASS TO BE ETCH MARKED (FRAMELESS U.N.O.) 38 SHOWER - HOT-MOP PAN, PROVIDE TILE W/. CEMENT BACKING MIN. 70" HIGH; NET AREA 7.1 S.F. MIN.; 30" DIA. CIRCLE MIN. (CPC 411.7) 39 WATER HEATER - TANK - SIZE PER T-24 REPORT REF. DTL. 1/AD-1 40 PROPERTY LINE 41 CUSTOM WOOD SCREEN WALL 42 INTERIOR GLASS GUARDRAIL - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTLS. 4, 9/AD-1 43 GARAGE DOOR - CUSTOM BUILT, REF. SCHED.- ARCH TO APPV. SHOP DWGS. PRIOR TO FAB. 44 SIDE YARD SETBACK 45 FRONT YARD SETBACK 46 CUSTOM CLOSET ISLAND. PER OWNER & I.D. 47 DECK DRAIN - SLOPE 2% MIN. - REF. DTL. 11/AD-1 48 OVERFLOW DRAINLINE- -IN WALL/ FROM ABOVE (TERMINATE ABV. EXT. FLATWORK) 49 DRAIN LINE - IN WALL/FROM ABV. (REF. CIVIL DWGS. & DETAILS) DIMENSION NOTE: ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE NEAREST 1/8" - CONTACT ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS. 1/4" = 1'-0"1 FIRST FLOOR PLAN 1/4" = 1'-0"2 SECOND FLOOR PLAN *HERS VERIFICATION REQUIRED- REFERENCE T-24.1 A ROUGH FRAMING: ALL EXTERIOR WALLS TO BE FRAMED WITH 2 X 6 STUDS SECOND AND THIRD FLOOR PLYWOOD TO BE 1-1/8" ENTIRE EXTERIOR TO BE SHEATHED WITH 1/2" PLYWOOD NO. REVISION DATE TRUE NORTH PROJECT NORTH 29 A-4.02 A-4.1 A-4.0 A-4.1 1 1 2 2 A-5.0 2 A-5.0 1 A-5.0 1 A-5.0 3 A-5.1 3 A-5.1 BONUS ROOM BATH #5 STORAGE ELEV. 2 A-5.1 2 A-5.1 1 A-5.1 1 A-5.1 FUTURE SPA LOCATION CABANA (COVERED) 4 A-5.0 4 A-5.0 54' - 7 3/4"20' - 0 3/8"27' - 10" 10' - 3 7/8"10' - 2 1/8"9' - 10 1/4" 2' - 1 1/8"6' - 0"2' - 1 1/8"2' - 4 7/8"2' - 4 7/8"5' - 0 1/2" 1' - 3 7/8"1' - 3"7' - 8 7/8"1' - 3 1/4"4' - 7"26' - 3 3/4"5' - 6"6 5/8"13' - 6"2' - 6"9' - 9 1/8"16' - 6 5/8"DN. STAIRS VIEW DECK ROOF DECK7' - 3 1/2"23' - 7 1/4"5' - 6"7' - 2 3/4"5' - 8 1/4"10' - 8 1/4"7' - 6 5/8"2' - 8 1/4"2' - 8 1/8"5' - 3 1/8"5' - 5 1/8"2' - 8 1/2"37 23 24 25 38 39 2627 52' - 6"25' - 7 1/4"24' - 5" 2' - 5 3/8"12' - 0"1' - 9 5/8"5' - 3 1/2"4' - 0 3/4" UP 4:124:124:12 4:12 4:124:123:123:123:12 3:12 3:123:123:1240 41 42 43 12 3 4 5 SHOWER SEAT6 7 3 8 6 7 9 9 103 11 2 11 3 PLANTED 12 12 12 TYP.11"CLR. 4' - 0" CLR. 4' - 0"TYP.11"CLR.4' - 2 1/4"CLR. 4' - 0 3/4" CLR. 4' - 1 1/8" TYP. 11"CLR.4' - 2 1/4"R @ 0' - 7 1/4"16 R @ 0' - 5 1/4"1 MECH 13 14 14 15 15 15 15 1515 1515 15 15 15 15 1616 16 16 16 16CLR.30" MIN.2' - 1 7/8" 2' - 6 3/8" 3' - 1 1/8"3' - 5"5' - 5 1/2"2' - 6 1/8"2' - 4 5/8"3' - 7 7/8"MIN. ø 30" 14 AD-1 14 AD-1 14 AD-1 14 AD-1 14 AD-1 CLR. 4' - 10 3/4"CLR.4' - 10 3/4"4 AD-1 1 A-5.2 1 A-5.23' - 3 3/4"2 % M I N 2% MIN 2% MIN 2 % M IN 2% MIN 2% MIN2% MIN2% MIN 2% MIN 2% MIN 2% MIN 2% MIN 2% MIN 2% MIN 2% MIN2% MIN2% MIN2% MIN2% MIN2% MIN2% MIN2% MIN 2% MIN 17 18 19 1919 19 20 2% MIN2% MIN21 22 22 22 22 22 22 23 24 PLAN LEGEND NEW WALL - 2 x 6 STUDS @ 16" O.C. NEW WALL - 2 x 4 STUDS @ 16" O.C. WALL W/. STONE VENEER - 2x STUDS @ 16" O.C. CONCRETE WALL - REF. STRUCT. DOUBLE WALL CONSTRUCTION - 2 x 4 MIN. STAGGERED STUD @ 16" O.C. WINDOW - REFERENCE SCHEDULE DOOR - REFERENCE SCHEDULE CABINET - BUILT IN CASEWORK COLUMN - WOOD, STEEL, REF. STRUCTURAL DWGS. FURNITURE - FOR PRESENTATION PURPOSES ONLY FIREPLACE - PREFAB GAS-ONLY APPLIANCE PLUMBING FIXTURE - SINK (AS SELECTED) PLUMBING FIXTURE - TOILET (AS SELECTED) LIGHTING FIXTURE - REFERENCE ELECTRICAL PLANS FIRE RATED CEILING ASS'Y. REF. DTL. 7/AD-1 INT. FIRE RATED PARTITION REF. DTL. 7/AD-1 101 1i ?KEYNOTE TAG - REFERENCE KEYNOTE LEGEND THIS SHT. WINDOW TAG - REFERENCE SHEET A-7.0 DOOR TAG - REFERENCE SHEET A-7.0 EXT. FIRE RATED PARTITION REF. DTL. 5/AD-1 EXISITING WALL TO REMAIN - 2 x 6 STUDS EXISITING WALL TO REMAIN - 2 x 4 STUDS CONCRETE MASONRY WALL - 6" CMU U.N.O. EXISITING WALL TO BE REMOVED AREA OF ADDITION WINDOW WALL TAG - REFERENCE SHEET A-7.01i JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONSOWNER INFORMATION:PROJECT NAME STATUS These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT A-2.1 06/22/18 1120-2018FLOOR PLANFANTICOLA RESIDENCE FANTICOLARESIDENCEANTONY & JOANNFANTICOLA1120 W. OCEAN FRONTNEWPORT BEACH, CA92661CDP 1120 W. OCEANFRONTNEWPORT BEACH, CA 92661CAITLIN SMITH NO. REVISION DATE 1/4" = 1'-0"1 THIRD FLOOR T.O.S. (TYP.) STAIRWAY NOTE: ALL STAIRWAYS SHALL HAVE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT CANDLE PER CRC R303.7 KEYNOTE LEGEND 1 INTERIOR GUARDRAIL - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTLS. 4, 9/AD-1 2 STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT CANDLE (CBC 1205.4) REF. DTL. 3/AD-1 3 FURNISHINGS - AS SELECTED 4 RESIDENTIAL ELEVATOR - 'ROCKY MOUNTAIN' OR EQUIV., SHAFT SIZE = 60" X 60" CLEAR - PROVIDE SHOP DWGS. TO ARCH. PRIOR TO PURCHASE & INSTALLATION 5 TOILET - MIN. 24" CLR. IN FRONT, MIN. 30" CLR. WIDTH, REF. CAL GREEN NOTES FOR FLOW RATE INFO. 6 SINK - AS SELECTED (VERIFY COUNTER OR WALL MOUNT FIXTURES W/. OWNER) 7 BASE CABINET - BUILT-IN, FINISH AS SEL. 8 PROVIDE POWER FOR BUILT-IN APPLIANCE/EQUIPMENT 9 COUNTERTOP - AS SELECTED 10 PROVIDE GAS STUB-OUT FOR EXTERIOR FIREPIT 11 EXTERIOR GLASS GUARDRAIL TO BE ACID-ETCHED WITH 'AVIPROTEK T' BY WALKER TEXTURES OR SIMILAR PRODUCT TO REDUCE POSSIBLE BIRD STRIKES - MIN. 42" HEIGHT - 4" MAX. SPHERE OPENING, REF. DTLS. 4, 13 & 14/AD-1 12 OUTLINE OF EXISTING STRUCTURE TO BE REMOVED 13 FAU - PROVIDE GAS S.O., POWER, AND VENTING AS REQ'D. BY MFGR. 14 A/C. CONDENSER UNIT - SIZE TBD - PROVIDE POWER AND SOUND DAMPENING PAD AS REQ'D. (SOUND ATT. REQ'D. BY C.N.B.) 15 ROOF - STANDING SEAM METAL W/. KYNAR FINISH - COLOR AS SELECTED - REF. MAT. SCHED. A-4 16 ALUMINUM GUTTER -RECESSED - KYNAR FINISH TO MATCH METAL ROOFING, SHAPE AS SEL. - PROVIDE SHOP DWGS. TO ARCH. 17 OVERFLOW DRAINLINE- -IN WALL/ FROM ABOVE (TERMINATE ABV. EXT. FLATWORK) 18 DECK DRAIN - SLOPE 2% MIN. - REF. DTL. 11/AD-1 19 LINEAR CHANNEL DRAIN - DRAIN TO NEAREST EXTERIOR WALL - COORDINATE W/. G.C. 20 CUSTOM AC WELL GATE - WD. - G.C. TO PROVIDE SHOP DWGS. FOR ARCH. APPROVAL 21 PROVIDE VENTILATION IN DOOR - HIGH AND LOW TO MEET FAU REQUIREMENTS 22 LINE OF ROOF ABOVE 23 TEMPERED GLASS ENCLOSURE - 1/2" THK. (MIN. 3/8" THK.) GLASS TO BE ETCH MARKED (FRAMELESS U.N.O.) 24 SHOWER - HOT-MOP PAN, PROVIDE TILE W/. CEMENT BACKING MIN. 70" HIGH; NET AREA 7.1 S.F. MIN.; 30" DIA. CIRCLE MIN. (CPC 411.7) DIMENSION NOTE: ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE NEAREST 1/8" - CONTACT ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS. *HERS VERIFICATION REQUIRED- REFERENCE T-24.1 ROUGH FRAMING: ALL EXTERIOR WALLS TO BE FRAMED WITH 2 X 6 STUDS SECOND AND THIRD FLOOR PLYWOOD TO BE 1-1/8" ENTIRE EXTERIOR TO BE SHEATHED WITH 1/2" PLYWOOD TRUE NORTH PROJECT NORTH 30 ROOF VENTILATION NOTES: (CRC R806) 1. ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE ENTRANCE OF RAIN OR SNOW. VENTILATION OPENINGS SHALL HAVE AT LEAST DIM. OF 1/16" MIN. AND 1/4" MAX. VENTILATION OPENINGS HAVING A LEAST DIMENSION LARGER THAN 1/4" SHALL BE PROVIDED W/. CORROSION-RESISTANT WIRE CLOTH SCREENING, HARDWARE CLOTH, OR SIMILAR MATERIAL WITH OPENINGS HAVING A LEAST DIM. OF 1/16" MIN. AND 1/4" MAX. OPENINGS IN ROOF FRAMING MEMBERS SHALL CONFORM TO THE REQ'TS. OF CRC R802.7. REQUIRED VENTILATION OPENINGS SHALL OPEN DIRECTLY TO THE OUTSIDE AIR. 2. THE NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1/150 OF THE AREA OF THE SPACE VENTILATED. THE NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1/300 IF ONE OR MORE OF THE FOLLOWING ARE MET; 1. IN CLIMATE ZONES 14 & 16, A CLASS I OR II VAPOR RETARDER IS INSTALLED ON THE WARM-IN-WINTER SIDE OF THE CEILING. 2. AT LEAST 40% AND MORE THAN 50% OF THE REQUIRED VENTILATING ARE IS PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE ATTIC OR RAFTER SPACE. UPPER VENTILATORS SHALL BE LOCATED NO MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE, MEASURED VERTICALLY, WITH THE BALANCE OF TEH REQUIRED VANTILATION PROVIDED BY EAVE OR CORNICE VENTS. WHERE THE LOCATION OF WALL OR ROOF FRAMING MEMBERS CONFLICTS WITH THE INSTALLATION OF UPPER VENTILATORS, INSTALLATION MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST OF THE SPACE SHALL BE PERMITTED. 3. WHERE EAVE OR CORNICE VENTS ARE INSTALLED, INSULATION SHALL NOT BLOCK THE FREE FLOW OF AIR. A MIN. OF A 1" SPACE SHALL BE PROVIDED BETWEEN THE INSULATION AND THE ROOF SHT'G. AND AT THE LOCATION OF THE VENT. 4. VENTILATORS SHALL BE INSTALLED IN ACCORDANCE WITH MFR'G.'S INSTALLATION INSTRUCTIONS. INSTALLATION OF VENTILATORS IN ROOF SYSTEMS SHALL BE IN ACCORDANCE W/. THE REQ'TS. OF SECTION R903. INSTALLATION OF VENTILATORS IN WALL SYSTEMS SHALL BE IN ACCORDANCE W/. THE REQ'TS. OF SECTION R703.1. 5. UNVENTED ATTIC ASSEMBLIES (SPACES BETWEEN THE CEILING JOISTS OF THE TOP STORY AND THE ROOF RAFTERS) AND UNVENTED ENCLOSED RAFTER ASSEMBLIES (SPACES BETWEEN CEILINGS THAT ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF FRAMING MEMBER/RAFTERS AND THE STRUCTURAL ROOF SHT'G. AT THE TOP OF THE ROOF FRAMING MEMBERS/RAFTERS) SHALL BE PERMITTED IF ALL OF THE FOLLOWING CONDITIONS ARE MET: 1. THE UNVENTED ATTIC SPACE IS COMPLETELY CONTAINED WITHIN THE BUILDING THERMAL ENVELOPE. 2. NO INTERIOR CLASS I VAPOR RETARDERS ARE INSTALLED ON THE CEILING SIDE (ATTIC FLOOR) OF THE UNVENTED ATTIC ASSEMBLY OR ON THE CEILING SIDE OF THE UNVENTED ENCLOSED RAFTER ASEEMBLY. 3. WHERE WOOD SHINGLES OF SHAKES ARE USED, A MIN. 1/4" VENTED AIR SPACE SEPARATES THE SHINGLES OR SHAKES AND THE ROOFING UNDERLAYMENT ABOVE THE STRUCTURAL SHT'G. 4. IN CALIFORNIA CLIMATE ZONES 14 & 16, ANY AIR- IMPERMEABLE INSULATION SHALL BE A CLASS II VAPOR RETARDER, OR SHALL HAVE A CLASS III VAPOR RETARDER COATING OR COVERING IN DIRECT CONTACT W/. THE UNDERSIDE OF THE INSULATION (SEE TITLE 24, PART 6, FIG. 100.1-A) 5. EITHER ITEMS 5.1, 5.2 OR 5.3 SHALL BE MET, DEPENDING ON THE AIR PERMEABILITY OF THE INSULATION DIRECTLY UNDER THE STRUCTURAL ROOF SHT'G. (NO INSULATION SHALL BE REQ'D. WHEN ROOF TILES, WOOD SHINGLES OR WOOD SHAKES, OR ANY OTHER ROOFING SYSTEM USING BATTENS AND NO CONT. UNDERLAYMENT IS INSTALLED. A CONT. LAYER SHALL BE CONSIDERED TO EXIST IF SHT'G., ROOFING PAPER OR ANY CONT. LAYER WHICH HAS A PERM RATE OF NO MORE THAN ONE PERM UNDER THE DRY CUP METHOD.); 5.1. AIR-IMPERMEABLE INSULATION ONLY. INSULATION SHALL BE APPLIED IN DIRECT CONTACT W/. THE UNDERSIDE OF THE STRUCTURAL ROOF SHT'G. 5.2. AIR-PERMEABLE INSULATION ONLY. IN ADDITION TO THE AIR-PERMEABLE INSULATION INSTALLED DIRECTLY BELOW THE STRUCTURAL SHT'G., RIDGE BOARD OR SHEET INSULATION W/. AN R-VALUE OR R-4 SHALL BE INSTALLED DIRECTLY ABOVE THE STRUCTURAL ROOF SHT'G. FOR CONDENSATION CONTROL. 5.3. AIR-IMPERMEABLE AND AIR-PERMEABLE INSULATION. THE AIR-IMPERMEABLE INSULATION SHALL BE APPLIED IN DIRECT CONTACT W/. THE UNDERSIDE OF THE STRUCTURAL ROOF SHT'G. FOR CONDENSATION CONTROL. THE AIR-PERMEABLE INSULATION SHALL BE INSTALLED DIRECTLY UNDER THE AIR-PERMEABLE INSULATION. 5.4. WHERE PREFORMED INSULATION BOARD IS USED AS THE AIR IMPERMEABLE INSULATION LAYER, IT SHALL BE SEALED AT THE PERIMETER OF EACH INDIVIDUAL SHEET INTERIOR SURFACE TO FORM A CONT. LAYER. REF. ROOF PLAN, SHT. A-5 OVERHANG 1/2"3 1/2"3x6 WD. FASCIA, AS SEL. BY ARCH. METAL GUTTER - ARCH. TO APPV. ROOFING PER PLAN & MAT. SCHED. 2X ROOF RAFTERS ROOF SHT'G PER STRUCT. INTERIOR FINISH PER PLANS METAL DRIP EDGE, 1/4" MIN. (TYP.) 2X SOLID BLK'G., FOR CONDITIONS WITHIN 5 FEET OF PROPERTY LINE DOUBLE 2x SOLID BLK'G. IS REQUIRED EXT. STUCCO FINISH - REF. ELEV. & MAT. SCHED. PLYWD. SHT'G. (PER STRUCT.) TYVEK OR EQUIV. BLD'G. WRAP 4x6 STAIN GRADE OUTLOOKER @ 30" O.C. (VERIFY W/. ARCH.) 2x6 T&G, DOUGLAS FIR OR EQUIV. ROOF PLATE, REF. SHT. A-5 FOR SPECIFIC CONDITIONS & ELEVS. FOR TYP. HTS. SISTER & SPIKE OUTLOOKER W/. RAFTERS. FILLED REGION INDICATES ATTIC SPACE- REF. ATTIC VENTILATION CALCS. ROOF PLAN LEGEND 2x6 WD. FASCIA - DOUGLAS FIR OR EQUIV., PAINT TO MATCH ROOFING PER PLAN, SHT. A-2.1 & MAT. SCHED., SHT. A-4.0 1-HR. COND. FOR EAVES CLOSER THAN 5' TO P.L. - PROVIDE DBL. 2X SOLID BLK'G. OR ONE (1) LAYER OF TYPE 'X' GYP. BD. ROOF SHT'G PER STRUCT. METAL DRIP EDGE, 1/4" MIN. (TYP.) EXT. FINISH PER PLAN ROOF SOFFIT - SISTER & SPIKE W/. RAFTER, REF. STRUCT. DWGS. 24" MAX. TO PL. 1x T&G SOFFIT - O/. BLD'G. WRAP, STAIN AS SEL. (ARCH. TO APPV.) PER PLAN (REF. SHT. A-2.1) OVERHANG 2X ROOF RAFTERS - REF. STRUCT. CDX PLYWD. SHT'G. - REF. STRUCT. DWGS. BLD'G. WRAP - 'TYVEK' OR EQUIV. INT. FINISH - GYP. BD., VERIFY W/. I.D. A-4.02 A-4.1 A-4.0 A-4.1 1 1 2 2 A-5.0 2 A-5.0 1 A-5.0 1 A-5.0 3 A-5.1 3 A-5.1 2 A-5.1 2 A-5.1 1 A-5.1 1 A-5.1 3:12 3:12 3:123:12 3:12 3:123:123:123:12 3:12 3:123:124:124:12 4:124:124:124 A-5.0 4 A-5.0 3:12 3:123:12 3:12 40.81' 40.81'40.81' 40.81'3:123:12 3:122% MIN.3:12 3:123:12 40.75' 40.76'3:123:123:123:12HT. CERT. REQ'D. HT. CERT. REQ'D. HT. CERT. REQ'D. 40.80' HT. CERT. REQ'D. HT. CERT. REQ'D. HT. CERT. REQ'D. HT. CERT. REQ'D. 40.58' (BELOW) VIEW DECK (BELOW) ROOF DECK 40.76' HT. CERT. REQ'D.HT. CERT. REQ'D. 35.82' T.W. 35.84' T.R. 35.84' T.R. 35.84' T.R. 34.79' T.W. 35.84' T.W. 35.09' T.W. 34.92' T.R. 35.09' T.R. 34.92' T.R.S.Y.S.B.3' - 0"F.Y.S.B. 9' - 0"S.Y.S.B.3' - 0"3' - 7" F.O.F. 1' - 0 1/2"1' - 1 1/2"F.O.F.2' - 0 1/2"24' - 5" 9 1/4" F.O.F. 27' - 0 3/4" 27' - 10"6 1/4"F.O.F.4' - 11 3/4"1"F.O.F.3' - 1"1' - 1"F.O.F.2' - 1"F.O.F. 8' - 6 1/2"5' - 6 5/8" 6 1/4" 10' - 10 1/8"F.O.F.2' - 0"1' - 1"1 2 F.O.F.3' - 0"1"F.O.F.3' - 9 3/4"9 1/4"F.O.F.3' - 9 3/4"9 1/4"F.O.F.3' - 0"1"F.O.F.2' - 0"1' - 1"3 3 4 3 5 3 4 6 6 6 6 4 34 7 7 4 7 8 8 8 3 3 3 3 33 3 366 6 6 6 6 4 A-3.0 4 A-3.0 4 A-3.0 4 A-3.0 4 A-3.0 4 A-3.0 3 A-3.0 3 A-3.0 3 A-3.0 3 A-3.0 3 A-3.0 2 A-3.0 2 A-3.0 2 A-3.0 2 A-3.0 2 A-3.0 2 A-3.0 2 A-3.0 14 AD-1 14 AD-1 14 AD-1 14 AD-1 14 AD-1 14 AD-1 1 A-5.2 1 A-5.2 4' - 11 1/8" 47' - 6 7/8"4' - 11 1/8" 43' - 9 5/8"6 1/4" REF. A-2.1 REF. A-2.1 1-HR 1-HR 1-HR 1-HR 8 5/8"6"7"6 1/2"6"6"6"4 3 4 2x ROOF RAFTER (PER STRUCT.) INTERIOR FINISH (PER PLANS, WHERE OCCURS) AIR-PERMEABLE INSULATION (PER PLANS) MIN. 30# ROOF FELT- (2) LAYERS GAF VERSASHIELD UNDERLAYMENT 15/32" CDX PLYWD. SHT'G. MIN. (REF. STRUCT) FASTENERS PER MFGR. INSTRUCTIONS 12 SLOPE PER PLAN STANDING SEAM METAL (ZINC OR EQUIV.) - REF. MAT. SCHED. A/A-5, CLASS 'A' ASSY. TYP.6" - 10"6" MIN. DOUBLE FOLD 3/4" LOCK, ALT. METHOD CLEATS @ 18" O.C. MAX. CONT. LOCK STRIP, SOLDERED ARCH. TO APPV. 12"-16"1-1/2" HIGHVALLEY DETAIL PRODUCT LISTING: ICC # ESR-2048, CB-150 UNVENTED ENCLOSED RAFTER ASSEMBLY NOTE: NO INTERIOR CLASS I VAPOR RETARDER SHALL BE INSTALLED ON THE CEILING SIDE (ATTIC FLOOR) OF THE UNVENTED ATTIC ASSEMBLY OR ON THE CEILING SIDE OF THE UNVENTED ENCLOSED ROOF FRAMING ASSEMBLY. 1/4" DENSGLASS OR EQUIV. 2x6 WD. FASCIA - DOUGLAS FIR OR EQUIV., PAINT TO MATCH ROOFING PER PLAN, SHT. A-2.1 & MAT. SCHED., SHT. A-4.0 1-HR. COND. FOR EAVES CLOSER THAN 5' TO P.L. - PROVIDE DBL. 2X SOLID BLK'G. OR ONE (1) LAYER OF TYPE 'X' GYP. BD. ROOF SHT'G PER STRUCT. METAL DRIP EDGE, 1/4" MIN. (TYP.) EXT. FINISH PER PLAN ROOF SOFFIT - SISTER & SPIKE W/. RAFTER, REF. STRUCT. DWGS. ROOF PLATE, REF. SECT. A-5.0 & ELEVS. FOR TYP. HTS. 24" MAX. TO PL. 1x T&G SOFFIT - O/. BLD'G. WRAP, STAIN AS SEL. (ARCH. TO APPV.) PER PLAN (REF. SHT. A-2.1) OVERHANG 2X ROOF RAFTERS - REF. STRUCT. CDX PLYWD. SHT'G. - REF. STRUCT. DWGS. BLD'G. WRAP - 'TYVEK' OR EQUIV. INT. FINISH - GYP. BD., VERIFY W/. I.D.9 1/4"1 1/2" 1X SLEEPERS FOR BUILT UP SLOPE, MIN. 2%/MAX 2.5:12 VAPOR BARRIER ('TYVEK' OR EQUIV.) MIN. TWO (2) LAYERS OF GRADE 'D' PAPER PER PLAN DISTANCE JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONSOWNER INFORMATION:PROJECT NAME STATUS These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT A-3.0 06/22/18 1120-2018ROOF PLANFANTICOLA RESIDENCE FANTICOLARESIDENCEANTONY & JOANNFANTICOLA1120 W. OCEAN FRONTNEWPORT BEACH, CA92661CDP 1120 W. OCEANFRONTNEWPORT BEACH, CA 92661CAITLIN SMITH KEYNOTE LEGEND 1 CHIMNEY CAP/SPARK ARRESTOR - [DTL. 21/AD-1] (NOTE: DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT THE TERMINATION OF FACTORY BUILT CHIMNEYS EXCEPT WHERE SUCH SHROUDS ARE LISTED AND LABELED FOR USE WITH THE SPECIFIC FAC. BLT. CHIMNEY SYSTEM AND ARE INSTALLED IN ACCORDANCE W/. MFGR. INST. INSTRUCTIONS. CMC 802.4.2.4) 2 CHIMNEY SHALL EXTEND AT LEAST 2' HIGHER THAN ANY PORTION OF THE BUILDING W/IN. 10', BUT SHALL NOT BE LESS THAN 3' ABV. THE HIGHEST POINT WHERE THE CHIMNEY PASSES THRU THE ROOF 3 4 KYNAR PAINTED ALUM. ROOF FASCIA - EAVE AS DIMENSIONED (REF. ROOF PLAN & RCP FOR DETAILS) 5 DOWNSPOUT - KYNAR FINISH TO MATCH METAL ROOFING, SHAPE AS SEL. (ARCH. TO APPROVE) 6 ROOF - STANDING SEAM METAL W/. KYNAR FINISH - COLOR AS SELECTED - REF. MAT. SCHED. A-4 7 LINE OF WALL(S) BELOW 8 OUTLINE OF EXISTING STRUCTURE TO BE REMOVED 1" = 1'-0"3 EAVE DETAIL 1" = 1'-0"4 RAKE DETAIL 1/4" = 1'-0"1 ROOF PLAN NOTE: ALL DIMS. ARE TO FACE OF STUD (F.O.S.) OR FACE OF SHT'G. (F.O.S.) TYP. U.N.O. EAVE DIMS. ARE FROM FACE OF SHT'G. TO FACE OF FINISH FASCIA A NO. REVISION DATE 1 1/2" = 1'-0"5 METAL ROOFING DETAIL TRUE NORTH PROJECT NORTH 1" = 1'-0"2 RECESSED GUTTER CONDITION NOTE: GRADE PLANE IS AT 11.81' 31 WINDOWS & DOORS: AUTHORIZED DEALER (PRODUCTS LISTED BELOW) SUPPLIER: ASSOCIATED BUILDING SUPPLY ADDRESS: STONE MILL DESIGN CENTER 2915 RED HILL AVE., SUITE F104, COSTA MESA, CA 92626 CONTACT: JOE YOUNAN PHONE: 949-872-3319 FAX: 206-666-2150 EMAIL: JYOUNAN@ABSSOCAL.COM WEB: WWW.ASSOCIATEDBUILDINGSUPPLY.COM ALUMINUM CLAD WINDOWS & PATIO DOORS MANUFACTURER: JELD-WEN WINDOWS & DOORS PRODUCT: CUSTOM COLLECTION ADDRESS: 3250 LAKEPORT BLVD. P.O. BOX 1329; KLAMATH FALLS, OREGON 97601 PHONE: 541-885-7412 OR 800-535-3936 FAX: 541-884-3331 WEB: WWW.JELD-WEN.COM MULTI SLIDE DOORS & STOREFRONT MANUFACTURER: WESTERN WINDOW SYSTEMS PRODUCT: SERIES 600 & STOREFRONT SYSTEMS ADDRESS: 5621 S. 25TH ST., PHOENIX, AZ 85040 PHONE: 877.268.1300 WEB: WWW.WESTERNWINDOWSYSTEMS.COM RECESSED GUTTERS: GARAGE DOORS: SUPPLIER:RANCH HOUSE DOORS WWW.RANCHHOUSEDOORS.COM STYLE: CUSTOM MATERIAL: CUSTOM BUILT, WOOD & GLASS WATERPROOF DECK MEMBRANE: FLASHING & WEATHERSTRIPPING: ROOFING: PRODUCT: STANDING SEAM METAL ROOFING, ULTRA-COOL, CB-150 MANUFACTURER: CUSTOM-BILT METALS 1333 CORPORATE DR., STE. 103 IRVING, TEXAS 75038 P: (888) 875-8484 COLOR:OLD TOWN GRAY, TO BE APPROVED BY ARCH. & OWNER NOTES:USE CONTINUOUS 12" OR 16" PANS - VERIFY W/. ARCH. SIZE & LOC'N. OF SEAMS. (NO TRANSVERSE SEAMS) REF. DTL. 7/A- 5 APPROVALS: ICC REPORT ESR-2048, CLASS 'A' ASSEMBLY WEIGHT:APPX. 2 PSF. MATERIAL: METAL - STAINLESS STEEL - PAINTED KYNAR SHAPE: SQUARE (5") (VERIFY W/. ARCH.) TUFFLEX POLYMERS 10880 POPLAR AVE. FONTANA, CA P: 909.349.2016 WWW.TUFFLEXPOLYMERS.COM CODE: ICC # ESR-2505 PROVIDE MIN. 24 GUAGE METAL (16 OZ.) SHEETING (TO MATCH) FOR ALL EXTERIOR FLASHING & WEATHERSTRIPPING APPLICATIONS. VERIFY W/. ARCHITECT ANY UNCONVENTIONAL ENVELOPE WATERPROOFING AREAS PRIOR TO INSTALLATION. EXTERIOR STONE/MASONRY VENEER EXTERIOR STUCCO: MANUFACTURER: MERLEX STUCCO 2911 ORANGE-OLIVE ROAD ORANGE, CA 92865 P: 714.627.1700 COLOR: TBD APPLICATION: THREE-COAT APPL., SMOOTH 7/8" W/. METAL LATH (DIAMOND OR EQUIV.) EAVE WOOD PANELING: SUPPLIER: TBD TYPE:CEDER OR AS SEL. SIZE: 1x HARDWOOD SIDING,1x4, COLOR: STAIN AS SEL. FINISH: CLEAR SEALANT, SEMI-GLOSS, COORD W/. ARCH. APPLICATION: T&G W/. SIMPLE REVEAL (COORD. WITH ARCH.) - SCORE & BACK PRIME SUPPLIER: SEPULVEDA BUILDING MATERIAL 28092 FORBES ROAD LAGUANA NIGUEL, CA 92677 P: 949.347.2100 STONE TYPE:LIMESTONE/ HONED (ARCH. TO VERIFY) COLOR: SILVERDALE, COLOR GROUT TO MATCH APPLICATION: TBD THICKNESS: THIN CUT VENEER WEIGHT: 15 LBS/ S.F. REF DTL. 8/AD-1 FIRST FLOOR (T.O.S.) 12.32' FIRST FLOOR (T.O.S.) 12.32' MAX. RIDGE HEIGHT 40.81' MAX. RIDGE HEIGHT 40.81' GRADE PLANE 11.81' GRADE PLANE 11.81' MAX FLAT 35.81' MAX FLAT 35.81' ROOF PLATE (TYP.) 38.82' ROOF PLATE (TYP.) 38.82' MASTER PLATE (TYP.) 21.32' MASTER PLATE (TYP.) 21.32' MASTER T.O.S. (TYP.) 22.40' MASTER T.O.S. (TYP.) 22.40' DECK T.O.S. (TYP.) 32.29' DECK T.O.S. (TYP.) 32.29'DECK PLATE (TYP.) 31.40' DECK PLATE (TYP.) 31.40' 3 A-5.1 4 A-5.0 1 16 15 37 9' - 0"1' - 1"9' - 0"10 5/8"10' - 1"9' - 10 5/8"24' - 0"29' - 0"9' - 0"1' - 1"9' - 0"10 5/8"6' - 6 3/8"10' - 1"9' - 10 5/8"P.L.P.L.ABV. F.F.42" MIN.ABV. F.F.42" MIN.1 1 1 2 3 4 5 6 6 7 3 :1 2 3:12 40.75'40.81' HT. CERT. REQ'D.HT. CERT. REQ'D.1' MAX.2' MIN.8 9 10 11 7 3 :1 2 3:12 7 6 OPENING 35.84' HT. CERT. REQ'D. 4 10AD-1 21 14 15 3 A-3.0 14 AD-1 13 AD-1 1 A-5.2 16 7 17 7 18 12 12 FIRST FLOOR (T.O.S.) 12.32' FIRST FLOOR (T.O.S.) 12.32' MAX. RIDGE HEIGHT 40.81' MAX. RIDGE HEIGHT 40.81' SECOND FLOOR PLATE (TYP.) 20.82' SECOND FLOOR PLATE (TYP.) 20.82' SECOND FLOOR T.O.S. (TYP.) 21.90' SECOND FLOOR T.O.S. (TYP.) 21.90' THIRD FLOOR T.O.S. (TYP.) 31.59' THIRD FLOOR T.O.S. (TYP.) 31.59' GRADE PLANE 11.81' GRADE PLANE 11.81' MAX FLAT 35.81' MAX FLAT 35.81' THIRD FLOOR PLATE (TYP.) 30.51' THIRD FLOOR PLATE (TYP.) 30.51' ROOF PLATE (TYP.) 38.82' ROOF PLATE (TYP.) 38.82' GARAGE (T.C.) 11.63' GARAGE (T.C.) 11.63' 3 A-5.1 4 A-5.0 18 6 17 5 38 39 45 P.L.P.L.8 1/4"8' - 6"1' - 1"8' - 7 1/4"1' - 1"7' - 2 3/4"9' - 7"9' - 8 1/4"9' - 2 1/4"1' - 1"10' - 3 1/4"24' - 0"29' - 0"12 3 7 12 11 ABV. F.F.42" MIN.6 7 45 3 ABV. F.F.42" MIN.7 4 4 :1 2 4:12 40.81' HT. CERT. REQ'D. 510 12 3:12 9 8 35.09' HT. CERT. REQ'D. 1313 13 AD-1 14 AD-1 1 A-5.2 19 40.80' HT. CERT. REQ'D. 20 2121 JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONSOWNER INFORMATION:PROJECT NAME STATUS These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT A-4.0 06/22/18 1120-2018EXTERIOR ELEVATIONS &MATERIAL SCHEDULEFANTICOLA RESIDENCE FANTICOLARESIDENCEANTONY & JOANNFANTICOLA1120 W. OCEAN FRONTNEWPORT BEACH, CA92661CDP 1120 W. OCEANFRONTNEWPORT BEACH, CA 92661CAITLIN SMITH KEYNOTE LEGEND 1 FURNISHINGS - AS SELECTED 2 PROVIDE GAS STUB-OUT FOR EXTERIOR FIREPIT 3 STONE VENEER - REF. DTL. 8/AD-1 & MATERIAL LEGEND 4 ROOF - STANDING SEAM METAL W/. KYNAR FINISH - COLOR AS SELECTED - REF. MAT. SCHED. A-4 5 6 EXTERIOR GLASS GUARDRAIL TO BE ACID-ETCHED WITH 'AVIPROTEK T' BY WALKER TEXTURES OR SIMILAR PRODUCT TO REDUCE POSSIBLE BIRD STRIKES - MIN. 42" HEIGHT - 4" MAX. SPHERE OPENING, REF. DTLS. 4, 13 & 14/AD-1 7 STUCCO FINISH - MIN. 7/8" THK. W/. DIA. LATH, COLOR AS SEL. 8 CHIMNEY SHALL EXTEND AT LEAST 2' HIGHER THAN ANY PORTION OF THE BUILDING W/IN. 10', BUT SHALL NOT BE LESS THAN 3' ABV. THE HIGHEST POINT WHERE THE CHIMNEY PASSES THRU THE ROOF 9 CHIMNEY CAP/SPARK ARRESTOR - [DTL. 21/AD-1] (NOTE: DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT THE TERMINATION OF FACTORY BUILT CHIMNEYS EXCEPT WHERE SUCH SHROUDS ARE LISTED AND LABELED FOR USE WITH THE SPECIFIC FAC. BLT. CHIMNEY SYSTEM AND ARE INSTALLED IN ACCORDANCE W/. MFGR. INST. INSTRUCTIONS. CMC 802.4.2.4) 10 KYNAR PAINTED ALUM. ROOF FASCIA - EAVE AS DIMENSIONED (REF. ROOF PLAN & RCP FOR DETAILS) 11 DOWNSPOUT - KYNAR FINISH TO MATCH METAL ROOFING, SHAPE AS SEL. (ARCH. TO APPROVE) 12 CUSTOM ARCH. WOOD SCREEN - 2X4 WOOD SLATS SPACED 5" O.C. - COLOR & STAIN AS SELECTED - ARCH. TO APP'V. PRIOR TO INSTALLATION 13 (N.) CUSTOM WOOD GATE - PER OWNER, STAIN & SEAL, ARCH TO APPRV. (MAX. 6' HT. ABOVE NATURAL GRADE) 14 T&G WD. PANELING - AS SEL., ARCH. TO APPV. REF. DTL. 17/AD-1 15 EXTERIOR GLASS GUARDRAIL - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTLS. 4, 9/AD-1" 16 PARAPET WALL - WOOD CAP FINISH O/. FLASHING, SLOPED TOP (2% MIN.) 17 DECO. WOOD BEAM. - ARCH TO APPRV. LOC'N & MATERIAL. 18 METAL PANEL - ARCH TO APPV. COLOR - METAL CAP FINISH O/. FLASHING, SLOPED TOP (2% MIN.)" 19 EXPOSED STRUCTURAL STEEL COLUMN, SIZE PER STRUCT.; PAINT & SEAL AS SEL. (ARCH. TO APPV.) 20 EXTERIOR GLASS STAIR MOUNTED GUARD - 42" ABV. NOSING/LANDING- REF. DTLS. , 3, 4, 9/AD-1 21 VERTICAL WOOD SIDING - WOOD T&G STAIN & SEAL AS SEL. ARCH. TO APPRV." MATERIAL SCHEDULEA NOTE: REF. ROOF PLAN (A-3) FOR ALL PLATE HTS. & RIDGE HTS. NOTE: FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT LABELS. NO. REVISION DATE 1/4" = 1'-0"1 FRONT ELEVATION 1/4" = 1'-0"2 REAR ELEVATION 32 FIRST FLOOR (T.O.S.) 12.32' FIRST FLOOR (T.O.S.) 12.32' MAX. RIDGE HEIGHT 40.81' MAX. RIDGE HEIGHT 40.81' SECOND FLOOR PLATE (TYP.) 20.82' SECOND FLOOR T.O.S. (TYP.) 21.90' THIRD FLOOR T.O.S. (TYP.) 31.59' GRADE PLANE 11.81' GRADE PLANE 11.81' MAX FLAT 35.81' MAX FLAT 35.81' THIRD FLOOR PLATE (TYP.) 30.51' ROOF PLATE (TYP.) 38.82' ROOF PLATE (TYP.) 38.82' MASTER PLATE (TYP.) 21.32' MASTER T.O.S. (TYP.) 22.40' 2 A-5.0 DECK T.O.S. (TYP.) 32.29'DECK PLATE (TYP.) 31.40' GARAGE (T.C.) 11.63' 1 A-5.0 2 A-5.1 1 A-5.1 9' - 0"1' - 1"9' - 0"10 5/8"10' - 1"9' - 10 5/8"12 3 1314 12 11 25 910 2324 3:12 3 :1 2 3:12 40.80'40.76'40.75'2' MIN.1' MAX.35.82' T.W.35.84' T.W.ABV. F.F.42" MIN.ABV. F.F.42" MIN.9' - 2 1/4"1' - 1"8' - 7 1/4"1' - 1"7' - 2 3/4"10' - 3 1/4"9' - 8 1/4"4 3 1534 9 10 74 4 7 3 3 3 3 8 4 HT. CERT. REQ'D.HT. CERT. REQ'D.HT. CERT. REQ'D. 40.80' HT. CERT. REQ'D.5 11 5 6 12 P.L.P.L. 4 :1 2 3:12 8' - 6"1' - 1"9' - 7"29' - 0"24' - 0"ABV. F.F.42" MIN.ABV. F.F.42" MIN.5 6 34.92' 4 HT. CERT. REQ'D. HT. CERT. REQ'D.HT. CERT. REQ'D. 444 7 14 AD-1 14 AD-1 A-7.0 1 TYP. 2 A-7.0 3 A-7.0 6 10' MIN. 18' - 9 1/2" AD-1 21 16 17 OPENING FIRST FLOOR (T.O.S.) 12.32' FIRST FLOOR (T.O.S.) 12.32' MAX. RIDGE HEIGHT 40.81' MAX. RIDGE HEIGHT 40.81' SECOND FLOOR PLATE (TYP.) 20.82' SECOND FLOOR T.O.S. (TYP.) 21.90' THIRD FLOOR T.O.S. (TYP.) 31.59' GRADE PLANE 11.81' GRADE PLANE 11.81' MAX FLAT 35.81' MAX FLAT 35.81' THIRD FLOOR PLATE (TYP.) 30.51' ROOF PLATE (TYP.) 38.82' ROOF PLATE (TYP.) 38.82' MASTER PLATE (TYP.) 21.32' MASTER T.O.S. (TYP.) 22.40' 2 A-5.0 DECK T.O.S. (TYP.) 32.29' DECK PLATE (TYP.) 31.40'29' - 0"24' - 0"GARAGE (T.C.) 11.63' 1 A-5.0 2 A-5.1 1 A-5.1 3 :1 2 3:12 3 :1 2 3:12 3 :1 23:12 40.76'40.75'40.80'40.71'1' - 1"8' - 7 1/4"1' - 1"8' - 6"7' - 2 3/4"9' - 8 1/4"9' - 7"1' - 1"9' - 2 1/4"10' - 3 1/4"10 5/8"9' - 0"1' - 1"9' - 0"6' - 6 3/8"9' - 10 5/8"10' - 1"1' MAX.2' MIN.16 15 20 18 22 19 2627 17 7 21 7 8 2 P.L.P.L.ABV. F.F.42" MIN.ABV. F.F.42" MIN.1 2 3 :1 2 4:12ANB. F.F.42" MIN.ABV. F.F.42" MIN.3 3 HT. CERT. REQ'D.HT. CERT. REQ'D.HT. CERT. REQ'D.HT. CERT. REQ'D. 40.58' HT. CERT. REQ'D. 40.80' HT. CERT. REQ'D. 4 4 4 2 5 6 7 3 8 3 8 9 10 5 5 35.84' T.W. 11 7 5 6 12 813 4 HT. CERT. REQ'D.HT. CERT. REQ'D. 34.92' T.W. 4 4 4 4 HEAD HT.8' - 6"SILL HT.3' - 6"HEAD HT.8' - 0"SILL. HT.3' - 6"SILL HT.3' - 2"HEAD HT.6' - 8"35.84' T.O.R. HT. CERT. REQ'D.HEAD HT.7' - 6"A-7.0 1 TYP. 2 A-7.0 3 A-7.0 3' - 6"7' - 6"14 13 AD-1 14 AD-1 14 AD-1 4 15 5 5 5 OPENING WINDOWS & DOORS: AUTHORIZED DEALER (PRODUCTS LISTED BELOW) SUPPLIER: ASSOCIATED BUILDING SUPPLY ADDRESS: STONE MILL DESIGN CENTER 2915 RED HILL AVE., SUITE F104, COSTA MESA, CA 92626 CONTACT: JOE YOUNAN PHONE: 949-872-3319 FAX: 206-666-2150 EMAIL: JYOUNAN@ABSSOCAL.COM WEB: WWW.ASSOCIATEDBUILDINGSUPPLY.COM ALUMINUM CLAD WINDOWS & PATIO DOORS MANUFACTURER: JELD-WEN WINDOWS & DOORS PRODUCT: CUSTOM COLLECTION ADDRESS: 3250 LAKEPORT BLVD. P.O. BOX 1329; KLAMATH FALLS, OREGON 97601 PHONE: 541-885-7412 OR 800-535-3936 FAX: 541-884-3331 WEB: WWW.JELD-WEN.COM MULTI SLIDE DOORS & STOREFRONT MANUFACTURER: WESTERN WINDOW SYSTEMS PRODUCT: SERIES 600 & STOREFRONT SYSTEMS ADDRESS: 5621 S. 25TH ST., PHOENIX, AZ 85040 PHONE: 877.268.1300 WEB: WWW.WESTERNWINDOWSYSTEMS.COM RECESSED GUTTERS: GARAGE DOORS: SUPPLIER:RANCH HOUSE DOORS WWW.RANCHHOUSEDOORS.COM STYLE: CUSTOM MATERIAL: CUSTOM BUILT, WOOD & GLASS WATERPROOF DECK MEMBRANE: FLASHING & WEATHERSTRIPPING: ROOFING: PRODUCT: STANDING SEAM METAL ROOFING, ULTRA-COOL, CB-150 MANUFACTURER: CUSTOM-BILT METALS 1333 CORPORATE DR., STE. 103 IRVING, TEXAS 75038 P: (888) 875-8484 COLOR:OLD TOWN GRAY, TO BE APPROVED BY ARCH. & OWNER NOTES:USE CONTINUOUS 12" OR 16" PANS - VERIFY W/. ARCH. SIZE & LOC'N. OF SEAMS. (NO TRANSVERSE SEAMS) REF. DTL. 7/A- 5 APPROVALS: ICC REPORT ESR-2048, CLASS 'A' ASSEMBLY WEIGHT:APPX. 2 PSF. MATERIAL: METAL - STAINLESS STEEL - PAINTED KYNAR SHAPE: SQUARE (5") (VERIFY W/. ARCH.) TUFFLEX POLYMERS 10880 POPLAR AVE. FONTANA, CA P: 909.349.2016 WWW.TUFFLEXPOLYMERS.COM CODE: ICC # ESR-2505 PROVIDE MIN. 24 GUAGE METAL (16 OZ.) SHEETING (TO MATCH) FOR ALL EXTERIOR FLASHING & WEATHERSTRIPPING APPLICATIONS. VERIFY W/. ARCHITECT ANY UNCONVENTIONAL ENVELOPE WATERPROOFING AREAS PRIOR TO INSTALLATION. EXTERIOR STONE/MASONRY VENEER EXTERIOR STUCCO: MANUFACTURER: MERLEX STUCCO 2911 ORANGE-OLIVE ROAD ORANGE, CA 92865 P: 714.627.1700 COLOR: TBD APPLICATION: THREE-COAT APPL., SMOOTH 7/8" W/. METAL LATH (DIAMOND OR EQUIV.) EAVE WOOD PANELING: SUPPLIER: TBD TYPE:CEDER OR AS SEL. SIZE: 1x HARDWOOD SIDING,1x4, COLOR: STAIN AS SEL. FINISH: CLEAR SEALANT, SEMI-GLOSS, COORD W/. ARCH. APPLICATION: T&G W/. SIMPLE REVEAL (COORD. WITH ARCH.) - SCORE & BACK PRIME SUPPLIER: SEPULVEDA BUILDING MATERIAL 28092 FORBES ROAD LAGUANA NIGUEL, CA 92677 P: 949.347.2100 STONE TYPE:LIMESTONE/ HONED (ARCH. TO VERIFY) COLOR: SILVERDALE, COLOR GROUT TO MATCH APPLICATION: TBD THICKNESS: THIN CUT VENEER WEIGHT: 15 LBS/ S.F. REF DTL. 8/AD-1 JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONSOWNER INFORMATION:PROJECT NAME STATUS These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT A-4.1 06/22/18 1120-2018EXTERIOR ELEVATIONSFANTICOLA RESIDENCE FANTICOLARESIDENCEANTONY & JOANNFANTICOLA1120 W. OCEAN FRONTNEWPORT BEACH, CA92661CDP 1120 W. OCEANFRONTNEWPORT BEACH, CA 92661CAITLIN SMITH NO. REVISION DATE 1/4" = 1'-0"1 LEFT SIDE ELEVATION 1/4" = 1'-0"2 RIGHT SIDE ELEVATION KEYNOTE LEGEND 1 MAIN SERVICE PANEL, 400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION) 2 DOWNSPOUT - KYNAR FINISH TO MATCH METAL ROOFING, SHAPE AS SEL. (ARCH. TO APPROVE) 3 EXTERIOR GLASS GUARDRAIL TO BE ACID-ETCHED WITH 'AVIPROTEK T' BY WALKER TEXTURES OR SIMILAR PRODUCT TO REDUCE POSSIBLE BIRD STRIKES - MIN. 42" HEIGHT - 4" MAX. SPHERE OPENING, REF. DTLS. 4, 13 & 14/AD-1 4 STUCCO FINISH - MIN. 7/8" THK. W/. DIA. LATH, COLOR AS SEL. 5 ROOF - STANDING SEAM METAL W/. KYNAR FINISH - COLOR AS SELECTED - REF. MAT. SCHED. A-4 6 EXTERIOR GUARDRAIL - MIN. 42" HEIGHT - 4" MAX. SPHERE OPENING, REF. DTLS. 2, 4, 17/AD-1 7 STONE VENEER - REF. DTL. 8/AD-1 & MATERIAL LEGEND 8 FURNISHINGS - AS SELECTED 9 CHIMNEY SHALL EXTEND AT LEAST 2' HIGHER THAN ANY PORTION OF THE BUILDING W/IN. 10', BUT SHALL NOT BE LESS THAN 3' ABV. THE HIGHEST POINT WHERE THE CHIMNEY PASSES THRU THE ROOF 10 CHIMNEY CAP/SPARK ARRESTOR - [DTL. 21/AD-1] (NOTE: DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT THE TERMINATION OF FACTORY BUILT CHIMNEYS EXCEPT WHERE SUCH SHROUDS ARE LISTED AND LABELED FOR USE WITH THE SPECIFIC FAC. BLT. CHIMNEY SYSTEM AND ARE INSTALLED IN ACCORDANCE W/. MFGR. INST. INSTRUCTIONS. CMC 802.4.2.4) 11 CUSTOM ARCH. WOOD SCREEN - 2X4 WOOD SLATS SPACED 5" O.C. - COLOR & STAIN AS SELECTED - ARCH. TO APP'V. PRIOR TO INSTALLATION 12 KYNAR PAINTED ALUM. ROOF FASCIA - EAVE AS DIMENSIONED (REF. ROOF PLAN & RCP FOR DETAILS) 13 MOVEABLE BBQ UNIT - COORDINATE W/. OWNER - PROVIDE POWER & GAS AS REQ'D. BY MFG'R. 14 (N.) CUSTOM WOOD GATE - PER OWNER, STAIN & SEAL, ARCH TO APPRV. (MAX. 6' HT. ABOVE NATURAL GRADE) 15 PARAPET WALL - WOOD CAP FINISH O/. FLASHING, SLOPED TOP (2% MIN.) 16 DECORATIVE PENDANT LIGHT FIXTURE 17 DECO. WOOD TRIM 'BELLYBAND' - PAINT GRADE, SMOOTH FINISH, ARCH. TO APPROVE PROFILE NOTE: REF. ROOF PLAN (A-3) FOR ALL PLATE HTS. & RIDGE HTS. MATERIAL SCHEDULEA NOTE: REF. ROOF PLAN (A-3) FOR ALL PLATE HTS. & RIDGE HTS. NOTE: FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT LABELS. 33 FIREBLOCKING AND DRAFTSTOPPING SHALL BE INSTALLED TO CUT OFF ALL CONCEALED DRAFT OPENINGS (BOTH VERTICAL AND HORIZONTAL) AND SHALL FORM AN EFFECTIVE BARRIER BETWEEN FLOORS, BETWEEN A TOP STORY AND A ROOF OR ATTIC SPACE, AND SHALL SUBDIVIDE ATTIC SPACES, CONCEALED ROOF SPACES AND FLOOR-CEILING ASSEMBLIES. THE INTEGRITY OF ALL FIRE BLOCKS AND DRAFT STOPS SHALL BE MAINTAINED. FIRE BLOCKS. FIREBLOCKING SHALL BE PROVIDED IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES, AT THE CEILING AND FLOOR LEVELS AND AT 10-FOOT INTERVALS BOTH VERTICAL AND HORIZONTAL. FIRE BLOCK CONSTRUCTION. FIREBLOCKING SHALL CONSIST OF 2 INCHES NOMINAL LUMBER. FIRE BLOCKS MAY ALSO BE OF GYPSUM BOARD, CEMENT FIBER BOARD, BATTS OR BLANKETS OF MINERAL OR GLASS FIBER, OR OTHER APPROVED MATERIALS INSTALLED IN SUCH A MANNER AS TO BE SECURELY RETAINED IN PLACE. LOOSE- FILL INSULATION MATERIAL SHALL NOT BE USED. WALLS HAVING PARALLEL OR STAGGERED STUDS FOR SOUND-TRANSMISSION CONTROL SHALL HAVE FIRE BLOCKS OF BATTS OR BLANKETS OF MINERAL OR GLASS FIBER OR OTHER APPROVED FLEXIBLE MATERIALS. DRAFT STOPS. DRAFTSTOPPING SHALL BE PROVIDED IN THE LOCATIONS SET FORTH IN THIS SECTION. FLOOR-CEILING ASSEMBLIES. DRAFT STOPS SHALL BE INSTALLED IN FLOOR-CEILING ASSEMBLIES OF THE BUILDING. SUCH DRAFT STOPS SHALL BE IN LINE WITH WALLS SEPARATING INDIVIDUAL DWELLING UNITS FROM EACH OTHER AND FROM OTHER AREAS. ATTICS. DRAFT STOPS SHALL BE INSTALLED IN THE ATTICS, MANSARDS, OVERHANGS, FALSE FRONTS SET OUT FROM WALLS AND SIMILAR CONCEALED SPACES OF THIS BUILDING. SUCH DRAFT STOPS SHALL BE ABOVE AND IN LINE WITH THE WALLS SEPARATING INDIVIDUAL DWELLING UNITS FROM EACH OTHER AND FROM OTHER USES. DRAFT STOP CONSTRUCTION. DRAFTSTOPPING MATERIALS SHALL NOT BE LESS THAN ½-INCH GYPSUM BOARD, 3/8-INCH WOOD STRUCTURAL PANEL, 3/8-INCH TYPE 2-M PARTICLEBOARD OR OTHER APPROVED MATERIALS ADEQUATELY SUPPORTED. OPENINGS IN THE PARTITIONS SHALL BE PROTECTED BY SELF-CLOSING DOORS WITH AUTOMATIC LATCHES CONSTRUCTED AS REQUIRED FOR THE PARTITIONS. FIRE-BLOCKING & DRAFT-STOP NOTE INSULATION SCHEDULE: EXTERIOR WALL: 2 x 4 CONST. = R-13 MIN. 2 x 6 CONST. OR LARGER =R-19 RAISED FLOOR:R-30 MIN. ROOF:R-30 (REF. T-24 REPORT FOR MORE INFORMATION) NOTE: PROVIDE BID FOR INSULATION OF ENTIRE HOME NEW WALL - 2 x 6 STUDS @ 16" O.C. U.N.O. NEW WALL - 2 x 4 STUDS @ 16" O.C. U.N.O. WALL W/. STONE VENEER - 2x STUDS @ 16" O.C. U.N.O. CONCRETE RETAINING WALL - REF. STRUCTURAL SEPARATION LEGEND EXTERIOR FIRE RATED PARTITION REF. DTL. 5/AD-1 1 HR. FIRE RATED PARTITION REF. DTL. 7/AD-1 1 HR. FLOOR SYSTEM REF. DTL. 7/AD-1 INSULATED SYS. REF. INSULATION SCHEDULE THIS SHT. B FIRST FLOOR (T.O.S.) 12.32' FIRST FLOOR (T.O.S.) 12.32' MAX. RIDGE HEIGHT 40.81' MAX. RIDGE HEIGHT 40.81' GRADE PLANE 11.81' GRADE PLANE 11.81' MAX FLAT 35.81' MAX FLAT 35.81' MASTER PLATE (TYP.) 21.32' MASTER PLATE (TYP.) 21.32' MASTER T.O.S. (TYP.) 22.40' MASTER T.O.S. (TYP.) 22.40' DECK T.O.S. (TYP.) 32.29' DECK T.O.S. (TYP.) 32.29' DECK PLATE (TYP.) 31.40' DECK PLATE (TYP.) 31.40' 3 A-5.1 4 A-5.0 PL PL29' - 0"24' - 0"8' - 11 1/2"MASTER SUITE MASTER RETREAT LOUNGE GREAT ROOM8' - 8 1/2"1 1 13 5 2 9 9 10101414 15 16 1 MAX1' - 0"MIN.1' - 11 3/4"25 26 ABV. F.F.42" MIN.27 3:123:1 2 AD-1 14 AD-1 14 AD-1 21 AD-1 6 9' - 0"1' - 1"9' - 0"10 5/8"10' - 1"9' - 10 5/8"1 A-5.2 3' - 6 5/8"9' - 0"29 30 30 32 FIRST FLOOR (T.O.S.) 12.32' FIRST FLOOR (T.O.S.) 12.32' MAX. RIDGE HEIGHT 40.81' MAX. RIDGE HEIGHT 40.81' SECOND FLOOR PLATE (TYP.) 20.82' SECOND FLOOR T.O.S. (TYP.) 21.90' THIRD FLOOR T.O.S. (TYP.) 31.59' GRADE PLANE 11.81' GRADE PLANE 11.81' MAX FLAT 35.81' MAX FLAT 35.81' THIRD FLOOR PLATE (TYP.) 30.51' ROOF PLATE (TYP.) 38.82' ROOF PLATE (TYP.) 38.82' MASTER PLATE (TYP.) 21.32' MASTER T.O.S. (TYP.) 22.40' 2 A-5.0 DECK T.O.S. (TYP.) 32.29' DECK PLATE (TYP.) 31.40' GARAGE (T.C.) 11.63' GARAGE (T.C.) 11.63' 1 A-5.0 2 A-5.1 1 A-5.1 7' - 2 3/4"8' - 1 1/4"3:12 3 :1 2 3:12 3 :1 2 29' - 0"24' - 0"10' - 1"9' - 10 5/8"6' - 6 3/8"9' - 0"1' - 1"9' - 0"10 5/8"6' - 6 3/8"29' - 0"24' - 0"8' - 6"1' - 1"8' - 7 1/4"1' - 1"7' - 2 3/4"9' - 7"9' - 8 1/4"ABV. F.F.42" MIN.ABV. F.F.42" MIN.ABV. F.F.42" MIN.3:12 4 :1 2 26 27 18 19 20 25 21 22 212 7 15 7 ABV. F.F.42" MIN.BEDROOM #3 W.I.C.ELEV.DEN MASTER RETREAT MASTER BALCONY 3-CAR GARAGE FOYER PWDR.DINING GREAT ROOM8' - 7 1/4"8' - 0 5/8"8' - 0 5/8"8' - 7"9' - 0 1/4"8' - 8 1/2"8' - 6"8' - 5 5/8"11 16 17 1 18 1 19 6 4 2021 1 8 13 22 2 1 1 23 23 9 9 9 9 9 242424 10 1010 10 15 15 R @ 0' - 5 1/4"1 5/8"P.L.P.L. 28 27 7 AD-1 7 AD-1 AD-1 14 AD-1 13 AD-1 14 AD-1 13 A-3.0 3A-3.0 3 A-7.0 7 A-7.0 6 33 1515 15 34 35 FIRST FLOOR (T.O.S.) 12.32' FIRST FLOOR (T.O.S.) 12.32' MAX. RIDGE HEIGHT 40.81' MAX. RIDGE HEIGHT 40.81' GRADE PLANE 11.81' GRADE PLANE 11.81' MAX FLAT 35.81' MAX FLAT 35.81' MASTER PLATE (TYP.) 21.32' MASTER PLATE (TYP.) 21.32' MASTER T.O.S. (TYP.) 22.40' MASTER T.O.S. (TYP.) 22.40' DECK T.O.S. (TYP.) 32.29' DECK T.O.S. (TYP.) 32.29' DECK PLATE (TYP.) 31.40' DECK PLATE (TYP.) 31.40' 3 A-5.1 4 A-5.0 8' - 0 7/8"8' - 0 7/8"9' - 1"ABV. F.F.42" MIN.MAX.1' - 0"MIN.2' - 0"1 2 3 4 2 5 6 7 1 8 1 3 :1 2 29' - 0"24' - 0"9' - 0"1' - 1"9' - 0"10 5/8"10' - 1"9' - 10 5/8"PL PL 99 1 10 10 11 12 MASTER BATH MASTER RETREATMASTER W.I.C. KITCHEN DINING 15 15 15 15 5 25 26 29 27 AD-1 21 AD-1 6 AD-1 6 1 A-5.2 3' - 4 7/8"30 31 3 JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONSOWNER INFORMATION:PROJECT NAME STATUS These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT A-5.0 06/22/18 1120-2018BUILDING SECTIONSFANTICOLA RESIDENCE FANTICOLARESIDENCEANTONY & JOANNFANTICOLA1120 W. OCEAN FRONTNEWPORT BEACH, CA92661CDP 1120 W. OCEANFRONTNEWPORT BEACH, CA 92661CAITLIN SMITH KEYNOTE LEGEND 1 FURNISHINGS - AS SELECTED 2 COUNTERTOP - AS SELECTED 3 SHELF AND POLE - BUILT IN, FINISH AS SEL. 4 UPPER CABINET - BUILT-IN, FINISH AS SEL. 5 BASE CABINET - BUILT-IN, FINISH AS SEL. 6 CUSTOM BUILT DINING TABLE & KITCHEN ISLAND PER OWNER & ARCH. 7 DISHWASHER - AS SELECTED 8 WINE RACKS - AS SELECTED - PROVIDE POWER 9 FLOOR JOISTS - REF. STRUCT. 10 DECK FRAMING - REF. STRUCT. 11 DOWNSPOUT - KYNAR FINISH TO MATCH METAL ROOFING, SHAPE AS SEL. (ARCH. TO APPROVE) 12 ALUMINUM GUTTER -RECESSED - KYNAR FINISH TO MATCH METAL ROOFING, SHAPE AS SEL. - PROVIDE SHOP DWGS. TO ARCH. 13 SINK - AS SELECTED (VERIFY COUNTER OR WALL MOUNT FIXTURES W/. OWNER) 14 DECO. WOOD BEAM. - ARCH TO APPRV. LOC'N & MATERIAL. 15 CEILING FRAMING - REF. STRUCT. 16 VEHICLE - MINIMUM PARKING DIMENSIONS ON PLANS 17 RESIDENTIAL ELEVATOR - 'ROCKY MOUNTAIN' OR EQUIV., SHAFT SIZE = 60" X 60" CLEAR - PROVIDE SHOP DWGS. TO ARCH. PRIOR TO PURCHASE & INSTALLATION 18 FAU - PROVIDE GAS S.O., POWER, AND VENTING AS REQ'D. BY MFGR. 19 DOUBLE OVEN - AS SELECTED 20 KITCHEN EXHAUST HOOD - PROVIDE MIN. RATE OF 100 CFM - INSTALL & PROVIDE POWER PER MFGR'S. INSTRS. - VENT. TO EXT. 21 KITCHEN SINK - AS SELECTED 22 PROVIDE POWER FOR BUILT-IN APPLIANCE/EQUIPMENT 23 EXTERIOR GLASS GUARDRAIL TO BE ACID-ETCHED WITH 'AVIPROTEK T' BY WALKER TEXTURES OR SIMILAR PRODUCT TO REDUCE POSSIBLE BIRD STRIKES - MIN. 42" HEIGHT - 4" MAX. SPHERE OPENING, REF. DTLS. 4, 13 & 14/AD-1 24 ROOF RAFTERS - REF. STRUCT. 25 CHIMNEY CAP/SPARK ARRESTOR - [DTL. 21/AD-1] (NOTE: DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT THE TERMINATION OF FACTORY BUILT CHIMNEYS EXCEPT WHERE SUCH SHROUDS ARE LISTED AND LABELED FOR USE WITH THE SPECIFIC FAC. BLT. CHIMNEY SYSTEM AND ARE INSTALLED IN ACCORDANCE W/. MFGR. INST. INSTRUCTIONS. CMC 802.4.2.4) 26 CHIMNEY SHALL EXTEND AT LEAST 2' HIGHER THAN ANY PORTION OF THE BUILDING W/IN. 10', BUT SHALL NOT BE LESS THAN 3' ABV. THE HIGHEST POINT WHERE THE CHIMNEY PASSES THRU THE ROOF 27 EXTERIOR GLASS GUARDRAIL - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTLS. 4, 9/AD-1" 28 CUSTOM ARCH. WOOD SCREEN - 2X4 WOOD SLATS SPACED 5" O.C. - COLOR & STAIN AS SELECTED - ARCH. TO APP'V. PRIOR TO INSTALLATION 29 EXTERIOR RECESSED WALL MOUNTED LIGHT FIXTURE (HIGH EFFICIENCY) SIZE AS SEL., DOWNLIGHT TYP. U.N.O. 30 CEILING FAN - W/. LED FIXTURE, AS SELECTED. REQ'S. DIMMER/OCCUPANCY SENSOR 31 DECORATIVE PENDANT LIGHT FIXTURE 32 FIREPLACE - PREFABRICATED, WOOD BURNING, 'HEATILATOR' BIRMINGHAM 42" STLYE "BIR42" [DTL. 22/AD-1] (FACTORY BUILT FIREPLACES, CHIMNEYS, AND ALL OTHER COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING AND MFG'R. INSTALLATION INSTRUCTIONS. FIREPLACE MUST COMPLY W/. THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES.) 33 LINEAR FLUORESCENT FIXTURE - CEILING MOUNT (ALT. RECESS) - HIGH EFFICACY LUMINAIRE 34 EXPOSED STRUCTURAL STEEL COLUMN, SIZE PER STRUCT.; PAINT & SEAL AS SEL. (ARCH. TO APPV.) 35 DECO WOOD BEAM. PER INT. DESIGNER - STAIN & SEAL AS SEL. ARCH TO APPRV. NO. REVISION DATE 1/4" = 1'-0"1 TRANSVERSE SECTION 1/4" = 1'-0"4 LONGITUDINAL SECTION 1/4" = 1'-0"2 TRANSVERSE SECTION 34 2-WSW18x9 ABOVE 2-WSW18x9 ABOVE W12X106 W12X106 ABOVE ABOVE 1' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0" 2' - 0"2' - 0"2' - 0" MIN 5" S.O.G. w/ #4@12" EA. WAY OVER 2" SAND OVER MOISTURE BARRIER (15 MIL. MIN.) OVERR 4" OF 1/2" CLEAN AGGREGATE 5" S.O.G. w/ #4@12" EA. WAY OVER 2" SAND OVER MOISTURE BARRIER (15 MIL. MIN.) OVERR 4" OF 1/2" CLEAN AGGREGATE 24"x24" GRADE BEAM w/ 4-#6 T&B AND #4@10" TIES 24"x24" GRADE BEAM 24"x24" GRADE BEAM w/ 4-#6 T&B AND #4@10" TIES 24"x24" GRADE BEAM w/ 6-#6 T&B AND #4@10" TIES 24"x24" GRADE BEAM w/ 4-#6 T&B AND #4@10" TIES 24"x24" GRADE BEAM w/ 4-#6 T&B AND #4@10" TIES 24"x24" GRADE BEAM 24"x24" GRADE BEAM 24"x24" GRADE BEAM w/ 4-#6 T&B AND #4@10" TIES 24"x24" GRADE BEAM 24"x24" GRADE BEAM 24"x24" GRADE BEAM 24"x24" GRADE BEAM 24" THK PAD w/ #5 @ 12" FOR ELEVATOR PIT 72"x72"x24" PAD FOOTING w/ 8-#6 EA. WAY, T&B 72"x72"x24" PAD FOOTING w/ 8-#6 EA. WAY, T&B REGISTER E D P R O FESSION A L ENGINEERS T ATE OF CA L I F O R N IASTRUCT U R A LTHOMASJ.B U R KENo. 5088 BURKE STRUCTURAL ENGINEERS, PC 151 KALMUS DRIVE, BLDG. E-140 COSTA MESA, CA.,92626 (657) 289-0460 REVISION BY DATE SCALE DRAWN BY: PROJECT NO.: SHEET 1/4" = 1'-0"ANTHONY AND JOANN FANTICOLAFANTICOLA RESIDENCEFOUNDATION PLAN2018-06-29 ZZ 18066 S1 1120 W. OCEANFRONT, NEWPORT BEACH, CA 92661FOUNDATION PLAN NOTES: 1. Design: Foundation designed in conformance with the recommendations by _GeoFirm Report No(s). 17-8158 Dated 03/02/2018 Signed by:Erik R. Hilde & Zi Wang 2. Footings: All footings shall extend a minimum depth of 24" below finished or natural grade into acceptable geological material as follows unless noted otherwise. 3. Allowable Bearing Pressure = 1800 psf. 4. Inspections: A Geotechnical Engineer shall certify in writing the adequacy of soil beneath foundations prior to placement of forms or reinforcing. A Geotechnical Engineer or his authorized representative shall inspect all subgrade preparation prior to the placement of any reinforcing steel or concrete and shall perform test as necessary to verify that such work is in conformance with the recommendations given in the soils report or building code. 5. The minimum ultimate compressive strength of all concrete shall be 4500 psi min at 28 days, unless noted otherwise. Design of mixes shall be by an approved testing laboratory and signed by a registered engineer. All concrete shall be "normal weight" unless noted otherwise. Concrete shall have a maximum water-cementitious material ratio, by weight, of 0.45. Cement shall conform to the ASTM C150-09 Type V. Aggregate: Aggregate shall conform to ASTM C33-08. Concrete Placement and Quality: Shall conform to applicable recommendations of ACI SP-15. A copy of SP-15 shall be available at construction site during the project. 6. Conduit and Pipes: Conduit and Pipes shall not be embedded in structural concrete except where specifically approved by the Engineer of Record. Maximum conduit and pipe size shall be 1/3 of the slab or wall thickness and located at its mid depth. Minimum spacing shall be 3 times the conduit/pipe diameter. Conduit and pipes shall not impair the strength of the member. Conduit and pipes shall not be aluminum. Conduit and pipes shall not displace more than 4% of the cross section area. 7. Construction Joints: Shall have entire surface removed to expose clean aggregate solidly embedded. The contractor shall obtain the approval of construction joint location in all slabs, beams, and walls. 8. All reinforcing steel shall be deformed bars which shall conform to the standard specifications of ASTM A-615 Grade 60. Tolerance for Rebar Placement: Tolerance for longitudinal location of bends and ends of reinforcement shall be plus or minus 2 inches except at discontinuous ends of members where tolerances shall be plus or minus 1/2 inch. Temperature Reinforcement shall have a lap of 48 bar diameters but not less than 12 inches, and the splice in adjacent bars shall be not less than 5 feet apart. 9. Minimum Cover: Reinforcing steel to have the following minimum cover: A. Concrete against earth (not formed) ..............................3" B. Concrete exposed to earth or weather (formed or troweled) #6 -#18 bars .................2" #5 and smaller ..................1-1/2" C. Slab-On-Grade ...............................................................@ CL of slab 35