Loading...
HomeMy WebLinkAbout09_Guo Residence Coastal Development Permit_PA2018-191 CITY OF NEWPORT BEACH ZONING ADMINISTRATOR STAFF REPORT October 25, 2018 Agenda Item No. 9 SUBJECT: Guo Residence (PA2018-191) Coastal Development Permit No. CD2018-077 SITE LOCATION: 515 36th Street APPLICANT: Jack Guo OWNER: Jack Guo PLANNER: Chelsea Crager, Associate Planner 949-644-3227, ccrager@newportbeachca.gov LAND USE AND ZONING  General Plan: RT (Two Unit Residential)  Zoning District : R-2 (Two-Unit Residential)  Coastal Land Use Category: RT-D (Two Unit Residential - 20.0 - 29.9 DU/AC)  Coastal Zoning District: R-2 (Two-Unit Residential) PROJECT SUMMARY The applicant requests athe demolition of a single family dwelling and the construction of a new, three-story, 4,082-square-foot residential duplex, including two attached 211 - square-foot single-car garages and two covered carports. The proposed development includes landscape, hardscape, accessory structures, and subsurface drainage facilities all within the confines of private property. The site is protected by an existing private bulkhead that will be reinforced in conjunction with the proposed construction. The design complies with all applicable development standards and no deviations are requested . RECOMMENDATION 1) Conduct a public hearing; 2) Find this project exempt from the California Environmental Quality Act (CEQA) pursuant to Section 15303 under Class 3 (New Construction or Conversion of Small Structures), because it has no potential to have a significant effect on the environment; and 3) Adopt Draft Zoning Administrator Resolution No. _ approving Coastal Development Permit No. CD2018-077 (Attachment No. ZA 1). 1 Guo Residence (PA2018-191) Zoning Administrator, October 25, 2018 Page 2 DISCUSSION Land Use and Development Standards  The project is located in the R-2 Zoning District, which allows a maximum of two residential dwelling units on a single legal lot, and is consistent with the City’s Coastal Land Use Plan, General Plan, and Zoning Code. A CDP is required and the property is not eligible for a Waiver for De Minimis Development because the property is located in the Appeal Area.  The property consists of one legal lot containing an existing single-family residence. The neighborhood is predominantly developed with two- and three-story, single- family and two-family residences. The design, bulk, and scale of the proposed development is consistent with the anticipated neighborhood pattern of development.  The proposed single-family residence and accessory structures conform to all applicable development standards, including floor area limit, setbacks, height, and off-street parking as evidenced by the project plans and illustrated in Table 1 below: Table 1 – Development Standards Development Standard Standard Proposed Setbacks (min.) Front (street) 5 feet 5 feet Sides 4 feet 4 feet Front (water) 30 feet 30 feet Allowable Floor Area 4,810 square feet 4,504 square feet Open Volume Area 361 square feet 366 square feet Parking 1 car garage plus 1 carport per unit (4 total) 1 car garage plus 1 carport per unit (4 total) Height 24 feet flat roof 29 feet sloped roof 23 feet 2 inches flat roof 29 feet sloped roof Hazards  The lowest finished first floor elevation of the proposed residence is 9.00 feet North American Vertical Datum of 1988 (NAVD88), which exceeds the minimum required 9.00-foot (NAVD88) elevation standard.  The existing development includes a private seawall/bulkhead along the waterway. A Bulkhead Condition Report prepared by PMA Consulting, Inc., dated July 24, 2018, concludes that the existing seawall wall is in good condition without noticeable evidence of distress. However, in order to protect the proposed new development, the report recommends that the wall be reinforced and repaired and provides specific recommendations on how this should be accomplished. Once 2 Guo Residence (PA2018-191) Zoning Administrator, October 25, 2018 Page 3 the wall has been reinforced and repaired, it is not anticipated that it will need further repair or replacement in the next 75 years.  A project-specific Coastal Hazards Analysis Report was prepared by PMA Consulting, Inc., dated July 24, 2018. The report concludes that flooding, wave run up and erosion will not significantly impact this property over the expected life of the proposed development, provided the existing seawall is reinforced and repaired as recommended.  Pursuant to Newport Beach Municipal Code (NBMC) Section 21.30.030(C)(3)(i)(iv), the property owner will be required to enter into an agreement with the City waiving any potential right to protection to address situations in the future in which the development is threatened with damage or destruction by coastal hazards (e.g., waves, erosion, and sea level rise). The property owner will also be required to acknowledge any hazards present at the site and unconditionally waive any claim to damage or liability against the decision authority, consistent with NBMC Section 21.30.015(D)(3)(c). Both requirements are included as conditions of approval that will need to be satisfied prior to the issuance of building permits for construction.  The property is located in an area known for the potential of seismic activity and liquefaction. All projects are required to comply with the California Building Code (CBC) and Building Division standards and policies. Geotechnical investigations specifically addressing liquefaction are required to be reviewed and approved prior to the issuance of building permits. Permit issuance is also contingent on the inclusion of design mitigation identified in the investigations. Construction plans are reviewed for compliance with approved investigations and CBC prior to building permit issuance. Water Quality  Pursuant to NBMC Section 21.35.050 (Water Quality and Hydrology Plan), because of the project site’s proximity to coastal waters, a Water Quality and Hydrology Plan (WQHP) was prepared by Robin Hamers & Associates, Inc., dated August 2018. The WQHP includes a polluted runoff and hydrologic site characterization, a sizing standard for Best Management Practices (BMPs), use of a low-impact development approach to retain the design storm runoff volume on site, and documentation of the expected effectiveness of the proposed BMPs. Construction plans will be reviewed for compliance with the approved WQHP prior to building permit issuance.  The project design addresses water quality with a construction erosion control plan that outlines temporary BMPs to be implemented during construction to minimize erosion and sedimentation, and to minimize pollution of runoff derived by construction chemicals and materials. No water quality impacts to coastal waters are anticipated based upon the location and e levation of the property. 3 Guo Residence (PA2018-191) Zoning Administrator, October 25, 2018 Page 4  The project includes a post construction drainage system that includes drainage and percolation features designed to retain dry weather and minor rain event run-off on- site. Any water not retained on-site is directed to the City’s storm drain system. Public Access  The project site is located between the nearest public road and the sea or shoreline; however, the project will not affect the public’s ability to gain access to, use, and/or view the coast and nearby recreational facilities. The existing residential development neither provides nor inhibits public coastal access. Implementation Plan Section 21.30A.040 (Determination of Public Access/Recreation Impacts) requires that the provision of public access bear a reasonable relationship between the requirement and the project’s impact and be proportional to the impact. In this case, the project replaces an existing single-family residence with a new residential duplex in an R-2 zoning district. Therefore, the project does not involve a change in land use, density or intensity that will result in significant increased demand on public access and recreation opportunities. Furthermore, the project is designed and sited so as not to block or impede existing public access opportunities.  The residential lot does not currently provide nor does it inhibit public coastal access. The proposed scope of work involves the removal and replacement of an existing single-family residence with a new residential duplex. Development will occur within the confines of private property, and existing coastal access conditions will not be affected. Coastal access is currently provided and will continue to be provided by street ends throughout the Balboa Peninsula with access to the beach and water.  The project site is not located adjacent to a coastal view road, public viewpoint, public park or beach, or public accessway, as identified in the Coastal Land Use Plan. Furthermore, an investigation of the project site and surrounding area did not identify any other public view opportunities. The project site may be located within the viewshed of distant public viewing areas. However, the project will replace an existing single-family home with a new residential duplex that complies with all applicable Local Coastal Program (LCP) development standards and maintains a building envelope consistent with the existing and anticipated neighborhood pattern of development. Therefore, the project does not have the potential to degrade the visual quality of the Coastal Zone or result in significant adverse impacts to public views. ENVIRONMENTAL REVIEW This project is exempt from the California Environmental Quality Act (CEQA) pursuant to Section 15303 under Class 3 (New Construction or Conversion of Small Structures) of the CEQA Guidelines, California Code of Regulations, Title 14, Chapter 3, because it has no potential to have a significant effect on the environment. 4 Guo Residence (PA2018-191) Zoning Administrator, October 25, 2018 Page 5 Class 3 exempts the construction and location of limited numbers of new, small facilities or structures including a residential duplex in a residential zone. The proposed project consists of the demolition of an existing single-family residence, and the construction of a new three-story, 4,082-square-foot, residential duplex and two attached 211-square- foot, single-car garages in the R-2 Zoning District. PUBLIC NOTICE Notice of this public hearing was published in the Daily Pilot, mailed to all owners and residential occupants of property within 300 feet of the boundaries of the site (excluding intervening rights-of-way and waterways), including the applicant, and posted on the subject property at least 10 days before the scheduled hearing, consistent with the provisions of the NBMC. Additionally, the item appeared on the agenda for this meeting, which was posted at City Hall and on the City website. APPEAL PERIOD: This action shall become final and effective 14 days following the date the Resolution is adopted unless within such time an appeal or call for review is filed with the Community Development Director in accordance with the provisions of Title 21 (Local Coastal Implementation Plan) of the Newport Beach Municipal Code. Final action taken by the City may be appealed to the Coastal Commission in compliance with Section 21.64.035 of the City’s certified LCP and Title 14 California Code of Regulations, Sections 13111 through 13120, and Section 30603 of the Coastal Act. For additional information on filing an appeal, contact the Planning Division at 949-644-3200. Prepared by: GBR/cc Attachments: ZA 1 Draft Resolution ZA 2 Vicinity Map ZA 3 Project Plans 5 Attachment No. ZA 1 Draft Resolution 6 RESOLUTION NO. ZA2018-### A RESOLUTION OF THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH APPROVING COASTAL DEVELOPMENT PERMIT NO. CD2018-077 TO DEMOLISH AN EXISTING SINGLE-FAMILY RESIDENCE AND CONSTRUCT A NEW THREE-STORY, RESIDENTIAL DUPLEX AND TWO ATTACHED SINGLE-CAR GARAGES AT 515 36TH STREET (PA2018-191) THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH HEREBY FINDS AS FOLLOWS: SECTION 1. STATEMENT OF FACTS. 1. An application was filed by Jack Guo (“Owner”), with respect to property located at 515 36th Street, requesting approval of a coastal development permit. 2. The property is legally described as Lot 8 and the Northeasterly Half of Lot 7 in Block 536 of Canal Section of Newport Beach. 3. The applicant proposed the demolition of a single-family dwelling and the construction of a new, three-story, 4,082-square-foot residential duplex, including two attached 211 - square-foot single-car garages and two covered carports. The proposed development includes landscape, hardscape, accessory structures, and subsurface drainage facilities all within the confines of private property. The site is protected by an existing private bulkhead that will be reinforced in conjunction with the proposed construction. The design complies with all applicable development standards and no deviations are requested. 4. The subject property is designated RT (Two Unit Residential) by the General Plan Land Use Element and is located within the R-2 (Two-Unit Residential) Zoning District. 5. The subject property is located within the coastal zone. The Coastal Land Use Plan category is RT-D (Two Unit Residential - 20.0 - 29.9 DU/AC) and the property is located within the R-2 (Two-Unit Residential) Coastal Zone District. 6. A public hearing was held on October 25, 2018, in the Corona del Mar Conference Room (Bay E-1st Floor) at 100 Civic Center Drive, Newport Beach. A notice of time, place and purpose of the hearing was given in accordance with the Newport Beach Municipal Code. Evidence, both written and oral, was presented to and considered by the Zoning Administrator at this hearing. SECTION 2. CALIFORNIA ENVIRONMENTAL QUALITY ACT DETERMINATION. 1. This project is categorically exempt pursuant to Title 14 of the California Code of Regulations Section 15303, Article 19 of Chapter 3, Guidelines for Implementation of the California Environmental Quality Act (CEQA) under Class 3 (New Construction or 7 Zoning Administrator Resolution No. ZA2018-### Page 2 of 9 Conversion of Small Structures), because it has no potential to have a significant effect on the environment. 2. Class 3 exempts the construction and location of limited numbers of new, small facilities or structures including one residential duplex in a residential zone. The proposed project consists of the demolition of an existing single-family residence and construction of a new three-story, 4,082-square-foot, residential duplex with two attached 211-square- foot, single-car garages in the R-2 Zoning District. SECTION 3. REQUIRED FINDINGS. In accordance with Section 21.52.015 (Coastal Development Permits, Findings and Decision) of the Newport Beach Municipal Code (NBMC), the following findings and facts in support of such findings are set forth: Finding: A. Conforms to all applicable sections of the certified Local Coastal Program. Facts in Support of Finding: 1. The proposed development complies with applicable residential development standards including, but not limited to, floor area limitation, setbacks, height, and parking. a. The maximum floor area limitation is 4,810 square feet and the proposed gross floor area is 4,504 square feet. b. The proposed development will provide the minimum required setbacks, which are five (5) feet along the front property line abutting 36th Street, four (4) feet along each side property line, and thirty (30) feet along the front property line abutting the waterway. c. The highest guardrail is no more than 24 feet, measured from the established grade level of 9.00 feet (NAVD 88) and the highest roof ridge is no more than 29 feet, measured from the established grade, which complies with the maximum height limitation. d. The project includes enclosed garage parking for two vehicles and covered carport parking for two vehicles, which complies with the minimum parking requirement for residential duplexes. 2. The neighborhood is predominantly developed with two- and three-story, single-family and two-family residences. The proposed design, bulk, and scale of the development will be consistent with the existing neighborhood pattern of development and expected future development. 8 Zoning Administrator Resolution No. ZA2018-### Page 3 of 9 3. The existing development includes a private seawall/bulkhead along the waterway. A Bulkhead Condition Report prepared by PMA Consulting, Inc., dated July 24, 2018, concludes that the wall is in good condition. In order to protect the proposed new development, the report recommends that the wall be reinforced and repaired, and provides specific recommendations on how this should be accomplished. Once the wal l has been reinforced and repaired, it is not anticipated that the wall will need further repair or replacement in the next 75 years. 4. Pursuant to NBMC Section 21.30.030(C)(3)(i)(iv), the property owner will be required to enter into an agreement with the City waiving any potential right to protection to address situations in the future in which the development is threatened with damage or destruction by coastal hazards (e.g., waves, erosion, and sea level rise). The property owner will also be required to acknowledge any hazards present at the site and unconditionally waive any claim to damage or liability against the decision authority, consistent with NBMC Section 21.30.015(D)(3)(c). Both requirements are included as conditions of approval that will need to be satisfied prior to the issuance of building permits for construction. 5. A project-specific Coastal Hazards Analysis Report was prepared by PMA Consulting, Inc., dated July 24, 2018. The report concludes that flooding, wave run up and erosion will not significantly impact this property over the life of the proposed development, provided the existing seawall is reinforced and repaired as recommended. 6. Pursuant to NBMC Section 21.35.050 (Water Quality and Hydrology Plan), because of the project site’s proximity to coastal waters, a Water Quality and Hydrology Plan (WQHP) was prepared by Robin Hamers & Associates, Inc., dated August 2018. The WQHP includes a polluted runoff and hydrologic site characterization, a sizing standard for Best Management Practices (BMPs), use of a low-impact development approach to retain the design storm runoff volume on site, and documentation of the expected effectiveness of the proposed BMPs. Construction plans will be reviewed for compliance with the approved WQHP prior to building permit issuance. 7. The property is located in an area known for the potential of seismic activity and liquefaction. All projects are required to comply with the California Building Code (CBC) and Building Division standards and policies. Geotechnical investigations specifically addressing liquefaction are required to be reviewed and approved prior to the issuance of building permits. Permit issuance is also contingent on the inclusion of design mitigation identified in the investigations. Construction plans are reviewed for compliance with approved investigations and CBC prior to building permit issuance. 8. The project design addresses water quality with a construction erosion control plan and a post construction drainage system that includes drainage and percolation features designed to retain dry weather and minor rain event run-off on-site. Any water not retained on-site is directed to the City’s storm drain system. 9. New landscaping will be verified for compliance with NBMC Section 21.30.075. A condition of approval is included that requires drought-tolerant, and prohibits invasive, species. Prior 9 Zoning Administrator Resolution No. ZA2018-### Page 4 of 9 to issuance of the building permits, the final landscape plans will be reviewed to verify invasive species are not planted. 10. The property is not located near designated public viewpoints or coastal view roads and will not negatively impact public coastal views. Finding: B. Conforms with the public access and public recreation policies of Chapter 3 of the Coastal Act if the project is located between the nearest public road and the sea or shoreline of any body of water located within the coastal zone . Facts in Support of Finding: 1. The project site is located between the nearest public road and the sea or shoreline; however, the project will not affect the public’s ability to gain access to, use, and/or view the coast and nearby recreational facilities. The existing residential development neither provides nor inhibits public coastal access. Implementation Plan Section 21.30A.040 (Determination of Public Access/Recreation Impacts) requires that the provision of public access bear a reasonable relationship between the requirement and the project’s impact and be proportional to the impact. In this case, the project replaces an existing single-family residence with a new residential duplex in an R-2 zoning district. Therefore, the project does not involve a change in land use, density or intensity that will result in significant increased demand on public access and recreation opportunities. Furthermore, the project is designed and sited so as not to block or impede existing public access opportunities. 2. The residential lot does not currently provide nor does it inhibit public coastal access. The proposed scope of work involves the removal and replacement of an existing single-family residence with a new residential duplex. Development will occur within the confines of private property, and existing coastal access conditions will not be affected. Coastal access is currently provided and will continue to be provided by street ends throughout the Balboa Peninsula with access to the water. 3. The project site is not located adjacent to a co astal view road, public viewpoint, public park or beach, or public accessway, as identified in the Coastal Land Use Plan. Furthermore, an investigation of the project site and surrounding area did not identify any other public view opportunities. The project site may be located within the viewshed of distant public viewing areas. However, the project will replace an existing single-family home with a new residential duplex that complies with all applicable Local Coastal Program (LCP) development standards and maintains a building envelope consistent with the existing and anticipated neighborhood pattern of development. Therefore, the project does not have the potential to degrade the visual quality of the Coastal Zone or result in significant adverse impacts to public views. SECTION 4. DECISION. NOW, THEREFORE, BE IT RESOLVED: 10 Zoning Administrator Resolution No. ZA2018-### Page 5 of 9 1. The Zoning Administrator of the City of Newport Beach hereby approves Coastal Development Permit No. CD2018-077, subject to the conditions set forth in Exhibit “A,” which is attached hereto and incorporated by reference. 2. This action shall become final and effective 14 days following the date this Resolution was adopted unless within such time an appeal or call for review is filed with the Community Development Director in accordance with the provisions of Title 21 Local Coastal Implementation Plan, of the Newport Beach Municipal Code. Final action taken by the City may be appealed to the Coastal Commission in compli ance with Section 21.64.035 of the City’s certified LCP and Title 14 California Code of Regulations, Sections 13111 through 13120, and Section 30603 of the Coastal Act. PASSED, APPROVED, AND ADOPTED THIS 25TH DAY OF OCTOBER, 2018. _____________________________________ Patrick J. Alford, Zoning Administrator 11 Zoning Administrator Resolution No. ZA2018-### Page 6 of 9 EXHIBIT “A” CONDITIONS OF APPROVAL 1. The development shall be in substantial conformance with the approved site plan, floor plans and building elevations stamped and dated with the date of this approval (except as modified by applicable conditions of approval). 2. Revisions to the approved plans may require an amendment to this Coastal Development Permit or the processing of a new coastal development permit. 3. Coastal Development Permit No. CD2018-077 shall expire unless exercised within 24 months from the date of approval as specified in Section 21.54.060 (Time Limits and Extensions) of the Newport Beach Municipal Code, unless an extension is otherwise granted 4. Prior to the issuance of a building permit, an agreement in a form approved by the City Attorney between the property owner and the City shall be executed and recorded waiving rights to the construction of future shoreline protection devices including the repair and maintenance, enhancement, reinforcement, or any other activity affecting the bulkhead, that results in any encroachment seaward of the authorized footprint of the bulkhead or other shoreline protective device. The agreement shall be binding against the property owners and successors and assigns. 5. Prior to the issuance of a building permit, the property owner shall submit a notarized signed letter acknowledging all hazards present at the site, assuming the risk of injury or damage from such hazards, unconditionally waiving any claims of damage against the City from such hazards, and to indemnify and hold harmless City, its City Council, its boards and commissions, officials, officers, employees, and agents from and against any and all claims, demands, obligations, damages, actions, causes of action, suits, losses, judgments, fines, penalties, liabilities, costs and expenses (including without limitation, attorney’s fees, disbursements and court costs) of every kind and nature whatsoever which may arise from or in any manner relate (directly or indirectly) to City’s approval of development. 6. The existing private seawall/bulkhead shall be reinforced and repaired, in keeping with the recommendations provided in the Bulkhead Condition Report prepared by PMA Consulting, Inc., dated July 24, 2018. 7. The project is subject to all applicable City ordinances, policies, and standards, unless specifically waived or modified by the conditions of approval. 8. The applicant shall comply with all federal, state, and local laws. Material violation of any of those laws in connection with the use may be cause for revocation of this coastal development permit. 12 Zoning Administrator Resolution No. ZA2018-### Page 7 of 9 9. This Coastal Development Permit may be modified or revoked by the Zoning Administrator if determined that the proposed uses or conditions under which it is being operated or maintained is detrimental to the public health, welfare or materially injurious to property or improvements in the vicinity or if the property is operated or maintained so as to constitute a public nuisance. 10. Best Management Practices and Good Housekeeping Practices shall be implemented prior to and throughout the duration of construction activity as designated in the Construction Pollution Prevention Plan . 11. Prior to issuance of the building permits, a copy of the Resolution, including conditions of approval Exhibit “A” shall be incorporated into the Building Division and field sets of plans. 12. Prior to issuance of building permits, the applicant shall submit to the Planning Division an additional copy of the approved architectural plans for inclusion in the coastal development permit file. The plans shall be identical to those approved by all City departments for building permit issuance. The approved copy shall include architectural sheets only and shall be reduced in size to 11 inches by 17 inches. The plans shall accurately depict the elements approved by this coastal development permit. 13. Prior to issuance of building permits, the applicant shall submit a final construction erosion control plan. The plan shall be subject to review and approval by the Building Division. 14. Prior to the issuance of building permits, the applicant shall submit a final landscape and irrigation plan. These plans shall incorporate drought tolerant plantings, non-invasive plant species and water efficient irrigation design. The plans shall be approved by the Planning Division. 15. All landscape materials and irrigation systems shall be maintained in accordanc e with the approved landscape plan. All landscaped areas shall be maintained in a healthy and growing condition and shall receive regular pruning, fertilizing, mowing, and trimming. All landscaped areas shall be kept free of weeds and debris. All irrigatio n systems shall be kept operable, including adjustments, replacements, repairs, and cleaning as part of regular maintenance. 16. Prior to the issuance of building permits, the applicant shall pay any unpaid administrative costs associated with the processing of this application to the Planning Division. 17. No demolition or construction materials, equipment debris, or waste, shall be placed or stored in a location that would enter sensitive habitat, receiving waters, or a storm drain or result in impacts to environmentally sensitive habitat areas, streams, wetland or their buffers. 13 Zoning Administrator Resolution No. ZA2018-### Page 8 of 9 18. The discharge of any hazardous materials into storm sewer systems or receiving waters shall be prohibited. Machinery and equipment shall be maintained and washed in confined areas specifically designed to control runoff. A designated fueling and vehicle maintenance area with appropriate berms and protection to prevent spillage shall be provided as far away from storm drain systems or receiving waters as possible. 19. Debris from demolition shall be removed from work areas each day and removed from the project site within 24 hours of the completion of the project. Stockpiles and construction materials shall be covered, enclosed on all sites, not stored in contact with the soil, and located as far away as possible from drain inlets and any waterway. 20. Trash and debris shall be disposed in proper trash and recycling receptacles at the end of each construction day. Solid waste, including excess concrete, shall be disposed in adequate disposal facilities at a legal disposal site or recycled at a recycling facility. 21. Should the property be sold or otherwise come under different ownership, any future owners or assignees shall be notified of the conditions of this approval by the current property owner or agent. 22. The applicant is responsible for compliance with the Migratory Bird Treaty Act (MBTA). In compliance with the MBTA, grading, brush removal, building demolition, tree trimming, and similar construction activities shall occur between August 16 and January 31, outside of the peak nesting period. If such activities must occur inside the peak nesting season from February 1 to August 15, compliance with the following is required to prevent the taking of Native Birds pursuant to MBTA: A. The construction area shall be inspected for active nests. If birds are observed flying from a nest or sitting on a nest, it can be assumed that the nest is active. Construction activity within 300 feet of an active nest shall be delayed until the nest is no longer active. Continue to observe the nest until the chicks have left the nest and activity is no longer observed. When the nest is no longer active, construction activity can continue in the nest area. B. It is a violation of state and federal law to kill or harm a native bird. To ensure compliance, consider hiring a biologist to assist with the survey for nesting birds, and to determine when it is safe to commence construction activities. If an active nest is found, one or two short follow-up surveys will be necessary to check on the nest and determine when the nest is no longer active. 23. To the fullest extent permitted by law, applicant shall indemnify, defend and hold harmless City, its City Council, its boards and commissions, officials, officers, employees, and agents from and against any and all claims, demands, obligations, damages, actions, causes of action, suits, losses, judgments, fines, penalties, liabilities, costs and expenses (including without limitation, attorney’s fees, disbursements and court costs) of every kind and nature whatsoever which may arise from or in any manner relate (directly or indirectly) to City’s approval of Guo Residence including, but not limited to, Coastal Development Permit No. 14 Zoning Administrator Resolution No. ZA2018-### Page 9 of 9 CD2018-077 (PA2018-191). This indemnification shall include, but not be limited to, damages awarded against the City, if any, costs of suit, attorneys' fees, and other expenses incurred in connection with such claim, action, causes of action, suit or proceeding whether incurred by applicant, City, and/or the parties initiating or bringing such proceeding. The applicant shall indemnify the City for all of City's costs, attorneys' fees, and damages, which City incurs in enforcing the indemnification provisions set forth in this condition. The applicant shall pay to the City upon demand any amount owed to the City pursuant to the indemnification requirements prescribed in this condition. 15 Attachment No. ZA 2 Vicinity Map 16 VICINITY MAP Coastal Development Permit No. CD2018-077 PA2018-191 515 36th Street Subject Property 17 Attachment No. ZA 3 Project Plans 18 GENERAL NOTES PROJECT TEAM SHEET INDEXPROJECT SUMMARY ABBREVIATIONS Door symbol - see door schedule Window symbol - see window schedule Keynote symbol - see keynotes Color/material symbol - see color/fin. list Equipment symbol - see equipment list Plumbing fixtures symbol per schedule Plumbing accessories symbol per schedule Ceiling height symbol Sheet Number Sheet Number Interior Elevation Number Section Number Sheet Number Detail Number Spot elevation A10 1 2 3 4 5 1 5 3 6 t h S T R E E T , N E W P O R T B E A C H , C A , 9 2 6 6 3 G U O R E S I D E N C E 2 A9 4 D1 A.B. ANCHOR BOLT ABV. ABOVE A.C. ASPHALT CONCRETE A.F.F. ABOVE FINISH FLOOR AL ALUMINUM ALT ALTERNATE APP APPROXIMATE ARCH ARCHITECTURAL BD BOARD BLW BELOW BET BETWEEN BLDG BUILDING BM BEAM BOT BOTTOM BYN BEYOND BW BOTH WAYS C.J. CEILING JOISTS C.M.U. CONCRETE MASONRY UNITS C.O. CLEAR OPENING CAB CABINET CLG CEILING CEM CEMENT CER CERAMIC CLR CLEAR COL COLUMN CONC CONCRETE CONN CONNECTION CONST CONSTURUCTION CONT CONTINUOUS CONTR CONTRACTOR D DEPTH D.F. DRINKING FOUNTAIN, DOUGLAS FIR D.S. DOWNSPOUT DB. DOUBLE DET DETAIL DIA DIAMETER DIM DIMENSION DN DOWN DR DOOR DWG DRAWING DWR DRAWER E.N. EDGE NAIL(ING) E.W. EACH WAY EA EACH ELEC ELECTRIC, ELECTRICAL ELEV ELEVATION E.I.F.S. EXTERIOR INSULATION AND FINISH SYSTEM EQ EQUAL EQUIP EQUIPMENT ESMT EASMENT EXH EXHAUST [E] EXISTING EXP EXPOSED F.N. FIELD NAILING F.O.C. FACE OF CONCRETE F.O.M. FACE OF MASONRY F.O.S. FACE OF STUD FRMG FRAMING FDN FOUNDATION FIN FINISH FLR FLOOR FT FOOT FTG. FOOTING GA GAUGE GALV GALVINIZED GAR GARAGE GFF GARAGE FINISH FLOOR G.F.I. GROUND FAULT INTERRUPTOR G.F.R.C. GLASS FIBER REINFORCED CEMENT G.I. GALVINIZED IRON GLS GLASS GR GRANITE GRD GRADE GYP. BD. GYPSUM BOARD H.M, HOLLOW METAL H.C. HOLLOW CORE HC HANDICAPPED HD HIGH DENSITY, HOLD DOWN HDW HARDWARE HR HOUR HT HEIGHT HRT. HEATER I.D. INSIDE DIAMETER IN INCH INS. INSULATION INT. INTERIOR JAN. JANITOR JT. JOINT KIT. KITCHEN L. LENGTH LAV. LAVATORY M.C. MEDICINE CHEST M.O. MASONRY OPENING MAS. MASONRY MAX. MAXIMUM MECH. MECHANICAL MED. MEDIUM MFG. MANUFACTURER MIN. MINIMUM MISC. MISCELLANEOUS MTD MOUNTED MTL. METAL [N] NEW N.I.C. NOT IN CONTRACT N.T.S. NOT TO SCALE NAT. NATURAL O.C. ON CENTER O.D. OUTSIDE DIAMETER OPN. OPENING OPP OPPOSITE P/A PLANTING AREA P.S.I. POUNDS / SQUARE INCH PL. PLATE PLAS PLASTER PLY PLYWOOD POL POLISH, POLISHED PR. PAIR PT. PAINT R RADIUS, RAFTER R.D. ROOF DRAIN R.O. ROUGH OPENING R.R. ROOF RAFTER R.S. ROUGH SAWN RA RETURN AIR REQ REQUIRED RI RISER RM ROOM R.O.W. RIGHT OF WAY S STAINLESS S.C. SOLID CORE SCH. SCHEDULE SECT. SECTION SH SHELF SHTG SHEATHING SHWR SHOWER SIM SIMULAR SPEC SPECIFICATIONS SQ SQUARE ST. STREET STD STANDARD STL STEEL STN STONE STUC STUCCO STRUCT STRUCTURAL SYM SYMMETRICAL T&B TOP AND BOTTOM T&G TOUNGE AND GROOVE T TREAD, TEMPERED GLASS TC TOP OF CONCRETE / CURB / CHIMNEY TD TOP OF DECK TP TOP OF PLATE TT TOP OF TRELLIS TR TOP OF ROOF TRAIL TOP OF HANDRAIL TW TOP OF WALL TEL TELEPHONE THK THICK TYP TYPICAL U.N.O. UNLESS NOTED OTHERWISE UR URINAL V.T. VINYL TILE V.T.R. VENT THROUGH ROUGH W WIDE, WIDTH W/ WITH W.C. WATER CLOSET, WALL COVERING WD WOOD WP WATERPROOF W.R. WATER RESISTANT A 1 1 pla-1 8'-0" A A a0.00' TRVICINITY MAP REVISIONS PROJECT SITE OWNER: Jack Guo 50 W. Lemon Ave, #23 Monrovia, CA 91016 (909) 319-6888 ARCHITECT:hudgins design group, inc. c/o: scott hudgins 32932 pacific coast hwy, #14-272 dana point, CA 92629 p. 949.322.7922 COASTAL HAZARDS: GEOLOGIST:Pacific Geotech, Inc 15038 Clark Ave., Hacienda Heights, CA 91745 (626) 333-8507 1 PLNG DIV. CDP CORRECTIONS #1 09/13/18 DEFERRED SUBMITTALS CITY NOTES 1. DESTRUCTIVE REMOVAL OF WORK PERFORMED WITHOUT PERMITS MAY BE REQUIRED FOR INSPECTION(S). 2. DEPUTY INSPECTORS ARE REQUIRED TO BE REGISTERED WITH THE CITY. 3. UNDERGROUND UTILITIES REQUIRED. 4. THE STRUCTURAL DESIGN AND DETAILS FULLY CONFORM TO ALL APPROPRIATE REQUIREMENTS OF THIS CODE, THE CALIFORNIA RESIDENTIAL CODE (R301.1.3 CRC) 5. APPLICATIONS FOR WHICH NO PERMIT IS ISSUED WITHIN 180 DAYS FOLLOWING THE DATE OF APPLICATION SHALL AUTOMATICALLY EXPIRE. (CRC R105.3.2) 6. EVERY PERMIT ISSUED SHALL BECOME INVALID UNLESS WORK AUTHORIZED IS COMMENCED WITHIN 180 DAYS OR IF THE WORK AUTHORIZED IS SUSPENDED OR ABANDON FOR A PERIOD OF 180 DAYS. A SUCCESSFUL INSPECTION MUST BE OBTAINED WITHIN 180 DAYS. A PERMIT MAY BE EXTENDED IF A WRITTEN REQUEST STATING JUSTIFICATION FOR EXTENSION AND AN EXTENSION FEE IS RECEIVED PRIOR TO EXPIRATION OF THE PERMIT AND GRANTED BY THE BUILDING OFFICIAL. NO MORE THAN ONE (1) EXTENSION MAY BE GRANTED. PERMITS WHICH HAVE BECOME INVALID SHALL PAY A REACTIVATION FEE OF APPROXIMATELY 50% OF THE ORIGINAL PERMIT FEE AMOUNT WHEN THE PERMIT HAS BEEN EXPIRED FOR UP TO SIX (6) MONTHS. WHEN A PERMIT HAS BEEN EXPIRED FOR A PERIOD IN EXCESS OF ONE (1) YEAR, THE REACTIVATION FEE SHALL BE APPROXIMATELY 100% OF THE ORIGINAL PERMIT FEE. (R105.5 CRC) 7. AN AUTOMATIC FIRE SPRINKLER SYSTEM IS REQUIRED 8. THIS PROJECT SHALL COMPLY WITH THE: 2016 CALIFORNIA RESIDENTIAL CODE (CRC), 2016 CALIFORNIA MECHANICAL CODE (CMC), 2016 CALIFORNIA PLUMBING CODE (CPC), 2016 CALIFORNIA ELECTRICAL CODE (CEC), 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE (CGBSC), 2016 CALIFORNIA ENERGY EFFICIENCY STANDARDS (CEES) AND THE CITY LOCAL ORDINANCES. 9. ISSUANCE OF A BUILDING PERMIT BY THE CITY OF NEWPORT BEACH DOES NOT RELIEVE APPLICANTS OF THE LEGAL REQUIREMENTS TO OBSERVE COVENANTS, CONDITIONS AND RESTRICTIONS WHICH MAY BE RECORDED AGAINST THE PROPERTY OR TO OBTAIN PLANS. YOU SHOULD CONTACT YOUR COMMUNITY ASSOCIATIONS PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION AUTHORIZED BY THIS PERMIT 10. PRIOR TO PERFORMING ANY WORK IN THE CITY RIGHT-OF-WAY AN ENCROACHMENT PERMIT MUST BE OBTAINED FROM THE PUBLIC WORKS DEPARTMENT 1. All work, including materials and workmanship, shall conform to the requirements of local codes, laws, and ordinances and as specified by all by all governing authorities where applicable. Reference is to the latest accepted edition or revision. In the event of conflict with code requirements, that code requirement or note which establishes the higher standard shall take precedence. 2. The intention of the Contract Documents is to include all labor and materials, equipment, and transportation necessary for the complete and proper execution of the work. 3. The Contractor shall visit the job site prior to bidding any portion of the work. The Contractor shall verify all dimensions and existing conditions prior to beginning work, including but not limited to existing interior walls and roof structures. Should any condition arise where the intent of the drawings is in doubt or where there is a discrepancy between the Contract Documents and the field conditions, or within the Contract Documents, the Contractor shall notify the Architect immediately for clarification. Acceptance of these contract documents releases Architect from any liability of inaccurate portray of existing conditions whatsoever as established by consulting engineers and/or surveyors. 4. Dimensions are from face of studs or to center of wall as indicated on drawings, unless noted otherwise. 5. Written dimensions take precedence. Do not scale drawings. Walls not dimensioned are to align with existing walls or be abutted or applied to existing walls per drawings. Doors not dimensioned and shown jamb tight shall be set 3" from perpendicular wall to outer edge of door jamb. 6. Reference to any detail or drawing is for convenience only and does not limit the application of such details or drawings. 7. The design, adequacy and safety of erection bracing, shoring, temporary supports, etc., is the sole responsibility of the Contractor. The Contractor shall be responsible for the stability of the structure and provide necessary bracing prior to the application of all shear walls, roof and floor diaphragms, and finish materials. The Contractor shall be responsible for initiating, maintaining, and supervising all safety precautions and programs in connection with the work. 8. The Structural, Mechanical, Plumbing, and Electrical Drawings, as well as the drawings of other consultants, are supplementary to the Architectural Drawings. It shall be the responsibility of the General Contractor to check with the Architectural Drawings before the installation of work shown on the drawings of consultants. The Contractor shall bring any discrepancy between the Architectural Drawings and the drawings of the consulting engineers to the attention of the Architect for clarification. Any work installed in conflict with the Architectural drawings and not brought to the Architect's attention shall be corrected by the Contractor at the Contractor's expense and at no expense to the Owner or Architect. 9. Prior to performance of work, the Contractor shall require each subcontractor to notify the Contractor of any work called out in the drawings for his trade that cannot be fully guaranteed. 10. Contractor shall verify the location and size of all openings with all drawings and manufactured items where applicable. 11. The Contractor shall supervise and direct the Work and be solely responsible for all construction, means, methods, techniques, sequences, procedures, safety and for coordinating all portions of the Work. 12. The Contractor here-in agrees to repair or replace any or all work, together with any other adjacent work which may be displaced in connection with such replacement, that may prove to be defective in workmanship or materials within a period of one year form the date of acceptance, ordinary wear and unusual abuse or neglect excepted. 13. Contractor shall protect all existing structures, landscaping, materials, etc., during construction. Contractor shall patch and repair all surfaces disrupted or damaged during construction to match existing adjacent surfaces. 14. The Contractor shall on a daily basis keep the premises free form all accumulations of waste material or rubbish caused by his employees, subcontractors, or work, and at the completion of the work shall remove all rubbish, debris, equipment, and surplus materials from in and about the building and leave the premises "broom clean". 15. Any deviation from the Construction Documents or specifications by the Contractor or Owner without the Architect's approval releases the Architect of responsibility and liability in connection with all work so involved. 16. Clarifications on and/or inconsistencies with the drawings and specifications shall be brought to the attention of the Architect by the Contractor prior to commencement of work. Additional charges will not be granted based on claims of incomplete, inaccurate, or inconsistent drawings and specifications. 17. Prior to any excavation, a meeting will be held on site that will be attended by the project engineer, geologist, project building inspector, general and shoring contractors. 18. A Cal/OSHA permit is required where excavations exceed 5ft and a copy of the permit shall be supplied to the city prior to issuing a building permit. There shall be no trenches or excavations 5 feet or more in depth into which a person is required to descend, or obtain permit from State of California, Division of Occupational Safety and Health (Cal/OSHA). This permit and any other safety permit shall be obtained prior to commence any work. Contact Cal/OSHA at 714-558-4451 for additional information. 19. The requirements of the 2016 edition of the California Building Code and 2016 California Residential Code (Title 24) have been taken in consideration. 20. All new utilities will be underground to nearest utility pole. 21. The responsible certified geotechnical engineer will inspect and approve all grading and excavations prior to placement of forms, reinforcing steel or concrete. In cases involving engineered fill, a soils engineer shall provide the inspection and approval. 22. Licensed civil engineer/ architect that prepared the drainage plan shall certify at the completion of the project that the site drainage is in substantial compliance with the approved drainage plan. 23. The plans shall comply with the 2016 California Codes. CBC, CRC, CPC, CMC, CEC and CGBS, 2016 Energy Code and all applicable Local codes and ordinances. 24. Project shall comply with NPDES, SUSMP and BMP requirements. 25. Contact dig alert. 26. Structural observations by design engineer. 27. Owners on adjacent properties that must underpin their buildings due to the proposed excavation shall be notified in writing ten days prior to beginning the excavation. Copies of these notification letters shall be provided to the city prior to beginning the excavation. 28. Termite protection. In geographical areas where hazard of termite damage is known to be very heavy, wood floor framing shall be of naturally durable species (termite resistant) or preservative treated in accordance with AWPA U1 for the species, product preservative and end use or provided with approved methods of termite protection. 2304.11.6 FIGURE 2603.8 29. Wood supported by exterior foundation walls. Wood framing members, including wood sheathing, that rest on exterior foundation walls and are less than 8 inches (203 mm) from exposed earth shall be of naturally durable or preservative-treated wood. 2304.11.2.2 30. Fasteners for preservative treated and fire-retardant-treated wood shall be of hot dipped zinc-coated galvanized steel, stainless steel, silicon bronze or copper. The coating weights for zinc-coated fasteners shall be in accordance with ASTM A 153. 2304.9.5. Exception: Fasteners other than nails, timber rivets, wood screws and lag screws shall be permitted to be of mechanically deposited zinc coated steel with coating weights in accordance with ASTMB695, Class 55 minimum. 2304.9.5. Fastenings for wood foundations shall be as required in AFPA Technical Report No. 7 31. Provide house street number visible and legible from the street with a minimum size of 4" high and 1/2" wide (CRC R319.1) SURVEYOR & CIVIL ENGINEER: ROBIN B. HAMERS & ASSOC., INC. 234 E. 17TH STREET, SUITE 205 COSTA MESA, CA 92627 p. (949) 548-1192 ADDRESS: DESCRIPTION REQUIRED/ALLOWED EXISTING PROPOSED (Yes/No) CONFORMS USE ZONE BUILDING SITE AREA BLDG SITE WIDTH (AVG.) BLDG SITE DEPTH (AVG.) MAX. BUILDING HEIGHT SETBACKS: Front (36th St.) BUILDING SITE COVERAGE ZONING STANDARDS PROJECT DATA DESCRIPTION HABITABLE AREA: 515 36TH ST., NEWPORT BEACH CA, 92663 RESIDENTIAL R-2 45'-0" 100'-0" 45% BLDG FOOTPRINT 2,021 SF R-2 Front (BAY) CODE ANALYSIS CODE: 2016 CBC, CRC, CMC, CEC, CPC, CGBS, CEES & NBMC TITLE 21 AND LOCAL CITY ORDINANCES. CONSTRUCTION TYPE: V-B (SPRNIKLERED) ZONING DESIGNATION: R2 OCCUPANCY CLASSIFICATION: R-3, U OCCUPANCY SEPARATIONS: 1-HR NUMBER OF STORIES: 3 FIRE SPRINKLERS (NFPA 13D): REQUIRED PROJECT ADDRESS 515 36th ST., NEWPORT BEACH, CA, 92663 ACCESSOR'S PARCEL NUMBER APN: 423 081 07 LEGAL LOT 8 BLOCK 536 LEVEL 1 OPEN VOLUME 4,500 SF N/A 29'-0" / 24'-0" 5'-0"Y Y 1. DEFERRED SUBMITTALS TO BE REVIEWED BY THE PROJECT ARCHITECT OR ENGINEER OF RECORD AND CERTIFIED PRIOR TO SUBMITTAL FOR PLAN REVIEW. 2. ELEMENTS OF A LIFE/SAFTEY NATURE MAY NOT BE DEFERRED, INCLUDING BUT NOT LIMITED TO: GUARD RAILS, HAND RAILS, STAIRS, EGRESS COMPONENTS, LIGHT & VENTILATION ELEMENTS, ETC. 3. DEFERRED SUBMITTALS ARE SUBJECT TO SEPARATE REVIEW AND PERMIT ISSUANCE. 4. ACCESSORY BUILDINGS, FIRE SPRINKLER SYSTEM, DEMOLITION, POOLS, SPAS, WALLS, SHORING, FENCES, PATIO COVERS AND OTHER FREESTANDING STRUCTURES REQUIRE SEPARATE REVIEWS AND PERMITS. 5. FIRE SPRINKLERS REQUIRED, CONSTRACTOR TO SUBMIT FIRE SPRINKLER DRAWINGS FOR ARCHITECT'S APPROVAL PRIOR TO SUBMITTING TO CITY. OBTAIN FIRE SPRINKLER PERMIT PRIOR TO CALLING FOR ROOF SHEATHING INSPECTION. GARAGE AREA: TOTAL 30'-0" Y TOTAL HABITABLE AREA: PMA Consulting Inc c/o: Plamen Petrov, C-66947 28161 Casitas Ct. Laguna Niguel, CA 92677 p.petrov@pma-bg.com 46% 2,051 SF 29'-0" / 23'-2" Y A0.1 TITLE SHEET A3.1 PROPOSED ELEVATIONS SITE PLANA1.1 A4.1 PROPOSED SECTIONS FLOOR PLAN - LEVEL 1PROJECT DESCRIPTION DEMO EXISTING 4 BED, 2.5 BATH, 2,143 SF, 2 STORY, RESIDENCE. NEW 2-UNIT RESIDENCE PROPOSED. EACH UNIT CONTAINS 3 BED, 4.5 BATH, 2,041 SF, 3 STORY, WITH EXTERIOR BALCONIES, FIREPITS, A/C, ATTACHED 1-CAR GARAGE AND CARPORT. NEW ON GRADE PLANTERS, DRIVEWAY, COVERED MECHANICAL/ STORAGE/ AND TRASH ENCLOSURES. CONSTRUCT REINFORCED/ RAISED SEAWALL PER BULKHEAD CONDITIONS REPORT & DESIGN. LEVEL 2 A3.2 PROPOSED ELEVATIONS 0'-0" EXTERIOR BALCONY AREA: Side 2'-9"Y4'-0"4'-0" A1.3 DEMO PLAN LEVEL 3 A2.1 A2.2 FLOOR PLAN - LEVEL 2 A2.3 FLOOR PLAN - LEVEL 3 A2.4 ROOF PLAN 45'-0" R-2 BUILDABLE AREA 2,405 SF N/A N/A A0.2 CITY NOTES - MINIMUM CONSTRUCTION REQUIREMENTS A0.3 CITY NOTES - CAL GREEN MINIMUM REQUIREMENTS SPECIAL INSPECTIONS 1. HERS VERIFICATION REQUIRED, SEE TITLE 24 SHEETS 2. REFER TO STRUCTURAL SHEETS FOR SPECIAL INSPECTIONS BY THE STRUCTURAL ENGINEER. SYMBOLS LANDSCAPE DESIGNER: hudgins design group, inc. c/o: scott hudgins 32932 pacific coast hwy, #14-272 dana point, CA 92629 A1.2 AREA CALCULATIONS C-1 CIVIL TITLE SHEET & NOTES C-2 GRADING PLAN, DETAILS & SECTIONS C-3 EROSION CONTROL PLAN & SOILS RECOMMENDATIONS C-4 TOPOGRAPHY SURVEY L-1 LANDSCAPE PLANTING PLAN PARKING: 2 PER UNIT; 1 IN A GARAGE AND 1 COVERED OR IN A GARAGE TOTAL (HABITABLE+GARAGE): SLOPE AND ESTABLISHED GRADE CALCULATION: SLOPE = [(6.85' - 6.25') / 65.00']100 = 0.9% ESTABLISHED GRADE = (6.85' + 6.25' + 6.28' + 6.51') / 4 = 6.47' *MINIMUM REQUIRED TOP OF SLAB ELEVATION ALLOWED PER COASTAL HAZARDS STUDY = 9.00' ** HEIGHT MEASUREMENT SHALL BE MEASURED FROM THE TOP OF SLAB ELEVATION 21.30.060.B.3 CITY OF NEWPORT BEACH LOCAL COASTAL PROGRAM (L.C.P.) PROJECT CONFORMS TO APPLICABLE SECTIONS OF THE CERTIFIED LOCAL COASTAL PROGRAM. UNIT BUNIT AREQ. / ALLOWED (2.0) 4,810 SF 15% / 361 SF 744 SF 1,117 SF 180 SF 2,041 SF 744 SF 1,117 SF 180 SF 2,041 SF 1,488 SF 2,234 SF 360 SF 4,082 SF 754 SF 754 SF 1508 SF 211 SF 211 SF 422 SF 2,252 SF 2,252 SF 4,504 SF 15% / 361 SF 366 SF 4,500 SF 2,405 SF 2,405 SF RESIDENTIAL RESIDENTIAL 50'-0" 5,000 SF N/A 100'-0" 5'-0" 39'-8"30'-0" N/A SW-2 SEA WALL PLAN, NOTES & DETAILS CONSTRUCTION POLLUTION PREVENTION PLANCPPP A0.1 NTS SHEET NUMBER PLOT DATE: SCALE: 9.18.18R E S I D E N C EN E W P O R T B E A C H5 1 5 3 6 t h S T R E E T1 hudgins design group, inc.G U O laguna beach, ca, 92651 t: 949.322.7922 1107 south coast hwy e: info@hudginsdesign.com CDP SUB. #2 09.18.18 hudgins design group, inc, expressly reserves its common law copyright and other property rights in these drawings. These drawings are not to be reproduced, changed, or copied in any form or manner whatsoever nor are they to be assigned to any third party without first obtaining theexpressed written permission of hudgins design group, inc. The drawings and specifications remain the property of hudgins design group, inc. Copies of the drawings and specifications retained by the client may be utilized only for his or her use and for occupying the project for which theywere prepared, and not for the construction of any other project.CDP SUB. #1 08.08.18 1 1 1 19 36th STREETKITCHEN STAIRSDWRANGE OVENREF. DINING SEATING KITCHEN STAIRS DWRANGEOVENREF. DINING SEATING45'-0"LOT4'-0"SYSB26'-6" 7'-6"37'-0"4'-0"SYSB1'-0"BATH 1 4'-6"14'-6" 8'-6"5'-0"10'-0"10'-0" 30'-0" FYSB TRASH 30'-0"5'-0" FYSB 7'-6"4'-6"14'-6" 8'-6" 10'-0" 30'-0" FYSB 5'-0" FYSB 4'-0"SYSB4'-6"37'-0"4'-0"SYSBGARAGE 2 20'-0" GARAGE 1 CARPORT 1 CARPORT 2 ENTRY LAUNDRY 5'-0"10'-0"10'-0"7'-8"10'-4"7'-8"10'-4"35'-0" PANTRY PANTRY BATH 1LAUNDRY STORAGE TRASH STORAGE UP UP FIRE FIRE W/D 10'-0" 30'-0" FYSB 5'-0" FYSB ELEC ELEC 26'-6" 10'-0" 30'-0" 10'-0"16'-1"4'-10"3'-0"1'-0"16'-1"3'-0"1 2'-0"2'-0"5'-0" 20'-0" 35'-0"5'-0" W/D 5'-0"3'-6" MICRO. MICRO. 5'-0"3'-6" 20'-0" 20'-0"4'-6"25 16 1 25 16 16 56 16 56 39 39 2'-6"7.75"7.75"8.28FS8.53F S 6.18FS8.70FSENTRY 9.17 FF LIVING 9.17 FF LIVING 9.17 FF AA4.1AA4.1B A4.1 B A4.1 2 45'-0"LOT4'-0"SYSB26'-6" 7'-6"37'-0"4'-0"SYSB1'-0"4'-6"14'-6" 8'-6"5'-0"10'-0"10'-0" 30'-0" FYSB 30'-0"5'-0" FYSB 7'-6"4'-6"14'-6" 8'-6" 10'-0" 30'-0" FYSB 5'-0" FYSB 45'-0"LOT4'-0"SYSB2'-8"37'-0"4'-0"SYSB2'-0"5'-0"7'-6"10'-4"7'-6"10'-4"10'-0" 30'-0" FYSB 5'-0" FYSB 26'-6" 10'-0" 30'-0" 10'-0"16'-1"4'-10"3'-0"1'-0"16'-1"3'-0"25 DRIVEWAY DRIVEWAY 20'-0"LOT 8 BLOCK 536 FF. 9.17' [N] DUPLEX 515 35TH STREET PROPOSED FOOTPRINT 2,050 SF PAD 8.09' 20'-0" 5'-0" 5'-0"9'-111 2"10'-0"10'-0"20'-0"20'-0" 5'-0"36TH STREET36TH STREET36TH STREET1 12 22 16 21 25 9 10 10 10 2 16 2 16 66 1 11 66 2 11 66 2 11 11 1 1 PLANTER PLANTER PLANTERPLANTER35'-0" TANDEM PARKING 35'-0" TANDEM PARKING6.85EG6.25EG6.28EG6.51EG10.23(E)TW10.13(E)TW6.03EG6.16EG6.17EG6.18EG6.15EG6.17EG9.08FS8.28FS8.28FS7.15EG10.61TW 10.23(N)TW10.61TW .25:12 SLOPE 10.5% AVG. SLOPE 10.5% AVG. SLOPE10.13(N)TWBENCH P/A P/ABENCH 7.75"9.17F F 9.17FF7.5"8.70FS8.70F S 2% AVG. SLOPE 2% AVG. SLOPE 1 6.72"6.28EG9.08F S 6.72"6.72"6.72"6.72"6.40FS6.43"9.08FS6.43"6.43"6.43"6.43" 29 29 10.61TW 10.61TW10.61TW 10.61TWFIREFIREPLANTER7.5 FGPLANTER7.5 FG7.11EG9.82TW9.82TW8.86'FS9.20FS.25:12 SLOPE .25:12 SLOPE .25:12 SLOPE 9.08FS8.86'F S9.20FS7.5" 35 35 66 19 38 38 28 28 ELEC ELEC 11 11 9 20 20 16 16 16 A1.1 1/8"=1'-0" SHEET NUMBER PLOT DATE: SCALE: 9.18.18R E S I D E N C EN E W P O R T B E A C H5 1 5 3 6 t h S T R E E T1 hudgins design group, inc.G U O laguna beach, ca, 92651 t: 949.322.7922 1107 south coast hwy e: info@hudginsdesign.com CDP SUB. #2 09.18.18 hudgins design group, inc, expressly reserves its common law copyright and other property rights in these drawings. These drawings are not to be reproduced, changed, or copied in any form or manner whatsoever nor are they to be assigned to any third party without first obtaining theexpressed written permission of hudgins design group, inc. The drawings and specifications remain the property of hudgins design group, inc. Copies of the drawings and specifications retained by the client may be utilized only for his or her use and for occupying the project for which theywere prepared, and not for the construction of any other project.CDP SUB. #1 08.08.18 SITE PLAN KEYNOTES MATERIALS LEGEND STONE FLOORING, PORTUGUESE LIMESTONESTN-1 WD-1 TRANSPARENT GLASSGLS-1 MTL-2 STN-2 TRANSPARENT TEMPERED GLASS, AT GUARDRAILSGLS-2 CON-1 INTEGRALLY COLORED SMOOTH TROWEL STUCCO, WHITESTUC PLANTING AREA - REFER TO LANDSCAPE PLANP/A (N) CONCRETE WALL BREAK METAL, PAINTED - 'KYNAR 500' TO MATCH WINDOWS WD-3 VEGETATION/LANDSCAPING PER LANDSCAPE PLANVEG (N) WALL TRASH STORAGE AREA, SCREENED FROM STREET A/C EQUIPMENT, SCREENED W/ SOUND ATTENUATION PER CITY AREA OF OPEN VOLUME - SEE AREA CALCS SHEET A1.2 OUTDOOR FIRE PIT W/ DRAINAGE, +18" A.F.F. PROPOSED MAILBOX LOCATION ASPHALT ROOF SHINGLES, CLASS A, DARK GRAY COLORASPH WOOD FLOORING / CEILING STONE VENEER, SILVER TRAVERTINE HARDSCAPE / PORCH / PATIO (N) SEAWALL EXTENSION PER 'SW' DRAWINGS PROPERTY LINE1 SETBACK ROOF - MIN. CLASS 'A' FIRE RATED BUILDING FOOTPRINT EDGE OF ROOF/ CEILING (ABV/ BLW/ BYD AS OCCURS) 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 EDGE OF WALL (ABV/ BLW/ BYD AS OCCURS) (E) WATER METER LOCATION (REF CIVIL & SURVEY DWGS) FAU - PROVIDE GAS S. O., POWER, AND VENTING AS REQ'D. BY MFGR. (CMC 904. 1) STRUCTURAL COLUMN / BEAM PER STRUCTURAL FF/ FS/ FG/ EG (ABOVE/ BELOW/ BEYOND AS OCCURS) (E) CURB/ EDGE OF PAVEMENT FIXED DATUM POINT/ BENCHMARK CONTINUOUS RECESSED STRIP DRAIN - SEE CIVIL DWG'S (E) GRADE (N) FINISH GRADE/ FINISH SURFACE GARAGE CENTERLINE OF RIGHT OF WAY WATER HEATER - TANK-LESS (ON DEMAND) WALL -MOUNT +44" MIN., VERIFY SIZE REQ'D. W/. MFGR. (PROVIDE GAS) DOOR/ WINDOW PER SCHEDULE (ABV/ BLW/ BYD AS OCCURS) WOOD DECK (ABV/ BLW/ BYD) O/ SLEEPERS O/ CONC BASE 42 43 EXTERIOR STAIRS/STEPS - REF. CIVIL DRAWINGS 44 (N) GATE - AS SELECTED 45 46 47 48 49 GARAGE DOOR & TRACK (ABV) - INSTALL PER MANUF. SPEC. 50 51 52 PROPOSED MAIN SERVICE PANEL, 400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION) - VERIFY LOCATION W/. SO. CA. EDISON 53 54 55 56 CABINETRY (N) DRIVEWAY PLANTING/SOFTSCAPE AREA - SEE LANDSCAPE PLANS PAVERS - SEE LANDSCAPE PLANS EXISTING / PROPOSED GAS METER LOCATION OUTLINE OF EXISTING STRUCTURE TO BE REMOVED/DEMOLISHED BBQ, PROVIDE GAS AND ELEC. PER OWNER BENCH, +18" A.F.F. (N) DECORATIVE CHIMNEY SHROUD MODEL S11 BY 'AMERICAN CHIMNEY SHROUD.' UL LISTING (MH30042) & WH LISTING (5091753). TERMINATE 2FT MINIMUM ABOVE BUILDING PER CRC R1003.9 ROOF CRICKET, BUILT-UP AS REQUIRED COUNTER, +36" A.F.F. ROOF DRAIN W/ OVERFLOW AND CONCEALED PIPES PER CPC TABLES 11-1 AND 11-2 57 58 ROOF RIDGE/ VALLEY 59 60 ROOF PARAPET COUNTER, +30" A.F.F. STEEL UTILITY DOOR, VERIFY LOUVER REQUIREMENT SKYLIGHT (ABV / BLW / BYD AS OCCURS) ICC-ES ESR 2415 61 RECESSED CURTAIN/SHADE TRACK, MOTORIZED W/ REMOTE 62 63 WOOD SIDING, 7" JAMES HARDIE PLANK, ARTISAN V-GROOVE KHAKI BROWN COLOR CONCRETE FLOORING/DECKING ADJACENT BUILDING PLANTER AREA COUNTER, +42" A.F.F. EXTERIOR SIDING, PER ELEVATIONS (E) UTILITY VAULT/BOX LOCATION (REF CIVIL & SURVEY DWGS) EXTERIOR GUARDRAIL, MIN HEIGHT +42" A.F.F. NOT USED DRAIN LINE, IN WALL/FROM ABV. REF. CIVIL DWGS. NOT USED (N) STAIRS W/ MAXIMUM RISER HEIGHT SHALL BE 7-3/4" AND A MINIMUM OF 4". MINIMUM TREAD DEPTH SHALL BE 10". PROVIDE ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT CANDLE (CBC 1205.4) 34"-38" HIGH GUARDRAIL/ HANDRAIL @ STAIR FRAMELESS TEMPERED/LAMINATED GLASS GUARDRAIL PER CBC 2407. INSTALL PER MANUF. SPECS, ICCES-ESR-3269 PROVIDE (N) FAU, HEAT PER CRC R303.9 GAS FIREPLACE - 'MONTIGO' - ANSI Z21.50 / CSA 2.22-2014 AND ANSI Z21.97 / CSA 2.41-2014. DIRECT VENT, SEALED COMBUSTION, FIXED TREMPERED GLASS FRONT MODEL R520. CERTIFICATE # 1455422 WD-2 WOOD SIDING, 2-3/4" VERTICAL RESYSTA, DARK GREY COLOR MTL-1 STANDING SEAM ZINC METAL ROOF, CLASS "A", DARK GREY W/ 16" CONTINUOUS PANS. 64 SETBACK AREA ALLOWED FOR MINOR STRUCTURES65 4 SIDED POLYGON USED TO ESTABLISH GRADE 66 FENCE / SITE WALL - 42" MAX. IN FRONT67 ADDITIONAL THIRD FLOOR SETBACK68 (E) FENCE / SITE WALL - 72" MAX. PROTECT IN PLACE. MTL-3 STEEL GUARDRAIL, PAINTED - 'KYNAR 500' TO MATCH WINDOWS MTL-4 METAL DOOR, PAINTED - 'KYNAR 500' SITE NOTES 1. FINISHED GRADE WITHIN 10 FEET OF THE NEW STRUCTURE/ADDITION SHALL BE SLOPED A MINIMUM 2% AWAY FROM THE BUILDING FOR DRAINAGE PURPOSES. 2. THE DISCHARGE OF ANY POLLUTANTS TO ANY STORM DRAINAGE SYSTEM IS PROHIBITED. NO SOLID WASTE, PETROLEUM BYPRODUCTS, SOIL PARTICULATES, CONSTRUCTION WASTE MATERIALS, OR WASTEWATER GENERATED ON CONSTRUCTION SITES OR BY CONSTRUCTION ACTIVITIES SHALL BE PLACED, CONVEYED OR DISCHARGED INTO THE STREET, GUTTER OR STORM DRAIN SYSTEM. 3. PRESERVATION AND USE OF AVAILABLE NATURAL RESOURCES SHALL BE ACCOMPLISHED THROUGH EVALUATION AND CAREFUL PLANNING TO MINIMIZE NEGATIVE EFFECTS ON THE SITE AND ADJACENT AREAS. PRESERVATION OF SLOPES, MANAGEMENT OF STORM WATER DRAINAGE AND EROSION CONTROLS SHALL COMPLY WITH CGBS SECTION 4.106. 4. THE IRRIGATION SYSTEM IS DESIGNED TO PREVENT RUNOFF, LOW HEAD DRAINAGE, OVERSPRAY, OR OTHER SIMILAR CONDITIONS WHERE IRRIGATION WATER FLOWS ONTO NON-TARGETED AREAS, SUCH AS ADJACENT PROPERTY, NON-IRRIGATED AREAS, HARDSCAPES, ROADWAYS OR STRUCTURES. 5. EXISTING AREA DRAINS TO REMAIN. UTILIZE EXISTING SUBSURFACE DRAINAGE SYSTEM. ANY NEW AREA DRAINS SHALL BE CONNECTED TO EXISTING SUBSURFACE DRAINAGE. 6. AN APPROVED ENCROACHMENT PERMIT IS REQUIRED FOR ALL WORK ACTIVITIES WITHIN THE PUBLIC RIGHT-OF-WAY. 7. ALL WORK RELATED TO WASTEWATER IN THE PUBLIC RIGHT-OF-WAY SHALL BE PERFORMED BY A C-42 LICENSED SANITATION SEWER CONTRACTOR OR AN "A" LICENSED GENRAL ENGINEERING CONTRACTOR. 8. A CAL-OSHA PERMIT IS REQUIRED FOR EXCAVATIONS DEEPER THAN 5 FEET AND FOR SHORING AND UNDERPINNING. 9. SEE SHEET A2.4 FOR ROOF PLAN INFORMATION NOT SHOWN ON THIS SHEET INCLUDING EAVE DETAILS AND PROJECTION DISTANCES. 10. IF APPLICABLE, REF. PRELIMINARY LANSCAPE PLAN, FOR ALL HARDSCAPE & PLANTING AREAS WITH REPECTIVE HEIGHTS AND MATERIALS. 11. ALL DIMENSIONS ARE TO FACE OF SHEATHING ( EXT. WALLS) OR FACE OF STRUCTURE F.O.S.) TYP. U. N. O. ROUNDED TO THE NEAREST 1/ 8" - CONTACT ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS. PROJECT NORTHTRUE NORTH37°ALL ACCESSORY STRUCTURES WITHIN FRONT SETBACKS ARE LIMITED IN HEIGHT TO 42" FROM EXISTING, PRECONSTRCUTINO GRADE. 1 20 KITCHEN STAIRSDWRANGE OVENREF. DINING SEATING KITCHEN STAIRS DWRANGEOVENREF. DINING SEATING BATH 1 TRASH GARAGE 2 GARAGE 1 CARPORT 1 CARPORT 2 ENTRY LAUNDRY PANTRY PANTRY BATH 1LAUNDRY STORAGE TRASH STORAGE UP UP FIRE FIRE W/D ELEC ELEC W/D MICRO. MICRO. ENTRY 9.17 FF LIVING 9.17 FF LIVING 9.17 FF18'-6"4'-6"7'-6" 22'-0"1'-3"18'-3"3'-6"5'-0"17'-4"3'-2"9'-6"17'-6"7'-2"10'-4"7'-8"1'-2"6'-6"18'-6"4'-6"7'-6" 22'-0"1'-3"18'-3"3'-6"5'-0"17'-4"3'-2"9'-6"10'-4"7'-8"1'-2"6'-6"17'-6"7'-2"GARAGE 211 SF GARAGE 211 SF STORAGE 73 SF MECH 4 SF HAB 21 SF HABITABLE 133 SF HABITABLE 36 SFHAB 61 SF HABITABLE 401 SF HAB 9 SF HAB 83 SF HAB 9 SF HAB 83 SF HABITABLE 401 SF HAB 61 SF HABITABLE 36 SF HABITABLE 133 SF HAB 21 SF MECH 4 SF STORAGE 73 SF OPEN VOLUME 300 SF 20'-8"14'-6"UNIT - AUNIT - BUNIT - AUNIT - BUP STAIRS STAIRS DNUPDN FIRE FIRE BATH 2 BATH 1 BATH 3 CLOSET CLOSETCLOSET LANDING BEDROOM 1 BATH 1 CLOSET BATH 2 BATH 3 BEDROOM 3 CLOSET BEDROOM 2 LANDING CLOSET DECK DECK (12'-0" X 12'-0") (11'-5" X 13'-8") BEDROOM 2 (11'-5" X 13'-8") BEDROOM 3 (12'-0" X 12'-0") (12'-6" X 17'-8") BEDROOM 1 (12'-6" X 17'-8") 2% AVG. SLOPE 2% AVG. SLOPE HABITABLE 179 SF HABITABLE 216 SF HABITABLE 189 SF DECK/ OPEN VOLUME 33 SF HAB 13 SF HABITABLE 489 SF HAB 8 SF HAB 8 SF HABITABLE 489 SF HAB 13 SF HABITABLE 189 SF HABITABLE 179 SF HABITABLE 216 SF 18'-6"1'-0"18'-6"1'-0"6'-2"6'-6"5'-10"5'-10"6'-6"6'-2"5'-0" 35'-0"3'-6"3'-9"26'-6" 7'-6" 27'-7" 32'-7" 26'-6"3'-6"35'-0" 5'-0"7'-6" HAB 23 SF 2'-8"8'-9"HAB 23 SF 2'-8"8'-9"3'-9"32'-7" 27'-7"DECK/ OPEN VOLUME 33 SFUNIT - AUNIT - BUNIT - AUNIT - BSTAIRS DN OUTDOOR COVERED CABANA DINING VIEW DECKFIRE OPEN TO BELOW BONUS STAIRS DN OUTDOOR COVERED CABANA DINING VIEW DECK OPEN TO BELOW BONUS FIREDWICE DWICE REF REF WINE WINE MECH MECH DECK 125 SF DECK 68 SF DECK 7 SF DECK 51 SF DECK 186 SF DECK 109 SF DECK 61 SF DECK 106 SF DECK 8 SF HABITABLE 169 SF HAB 11 SF MECH 42 SF MECH 42 SFDECK 7 SF DECK 125 SF DECK 68 SF DECK 51 SF DECK 186 SF HAB 11 SF DECK 109 SF HABITABLE 169 SF DECK 61 SF DECK 106 SF DECK 8 SF 15'-11"2'-1"2'-1"15'-11"7'-6"3'-0"11'-0"24'-0"11'-9"4'-6"5'-2"8'-2"3'-9"3'-9"3'-10"3'-10"8'-2"5'-2"11'-9" 13'-9"3'-6" 24'-0" 13'-0" 10'-11"2'-1"13'-9"3'-6" 11'-0"3'-0"7'-6"4'-4" 4'-4"16'-8"16'-8"17'-2"17'-2"16'-10"16'-10"4'-6"3'-2"3'-2"12'-4"12'-4"UNIT - AUNIT - BUNIT - AUNIT - BA1.2AREA TABULATION LEVEL 2 AREA CALCULATIONSLEVEL 1 AREA CALCULATIONS LEVEL 3 AREA CALCULATIONS AREA TABULATIONS DESCRIPTION HABITABLE AREA: LEVEL 1 GARAGE AREA: TOTAL HABITABLE AREA: LEVEL 2 EXTERIOR BALCONY AREA: LEVEL 3 744 SF 1,117 SF 180 SF 2,041 SF 211 SF LEVEL 1 0 SF 33 SF 721 SF LEVEL 2 LEVEL 3 754 SFTOTAL BALCONY AREA: OPEN VOLUME: LEVEL 1 150 SF 33 SF 0 SF LEVEL 2 LEVEL 3 REQUIRED/ ALLOWED (2.0) 4,810 SF BUILDABLE AREA:2,405 SF 15%/ 361 SFTOTAL OPEN VOLUME:183 SF TOTAL (HABITABLE + GARAGE)2,252 SF SHEET NUMBER PLOT DATE: SCALE: 8.8.18R E S I D E N C EN E W P O R T B E A C H5 1 5 3 6 t h S T R E E Thudgins design group, inc.G U O laguna beach, ca, 92651 t: 949.322.7922 1107 south coast hwy e: info@hudginsdesign.com CDP SUB. #1 08.08.18 hudgins design group, inc, expressly reserves its common law copyright and other property rights in these drawings. These drawings are not to be reproduced, changed, or copied in any form or manner whatsoever nor are they to be assigned to any third party without first obtaining theexpressed written permission of hudgins design group, inc. The drawings and specifications remain the property of hudgins design group, inc. Copies of the drawings and specifications retained by the client may be utilized only for his or her use and for occupying the project for which theywere prepared, and not for the construction of any other project.1/8"=1'-0" PROPOSED UNIT A PROPOSED UNIT B TOTAL 15%/ 361 SF 744 SF 1,117 SF 180 SF 1,488 SF 2,234 SF 360 SF 2,041 SF 4,082 SF 0 SF 33 SF 0 SF 66 SF 721 SF 1436 SF 754 SF 1508 SF 211 SF 422 SF 2,252 SF 4,504 SF 150 SF 33 SF 0 SF 183 SF 300 SF 66 SF 0 SF 366 SF MECHANICAL: STORAGE: 46 SF 46 SF 92 SF 73 SF 73 SF 146 SF 21 36th STREET2 LOT 8 BLOCK 536 2 STORY BUILDING 4 BED/ 2.5 BATH/ 2,143 SF 515 36TH ST. NEWPORT BEACH, CA EXISTING STRUCTURE - NOT A PART EXISTING STRUCTURE - NOT A PART EXISTING GANGWAY TO REMAIN 1 1 3 3 1 A1.3 1/8"=1'-0" SHEET NUMBER PLOT DATE: SCALE: 8.8.18R E S I D E N C EN E W P O R T B E A C H5 1 5 3 6 t h S T R E E Thudgins design group, inc.G U O laguna beach, ca, 92651 t: 949.322.7922 1107 south coast hwy e: info@hudginsdesign.com CDP SUB. #1 08.08.18 hudgins design group, inc, expressly reserves its common law copyright and other property rights in these drawings. These drawings are not to be reproduced, changed, or copied in any form or manner whatsoever nor are they to be assigned to any third party without first obtaining theexpressed written permission of hudgins design group, inc. The drawings and specifications remain the property of hudgins design group, inc. Copies of the drawings and specifications retained by the client may be utilized only for his or her use and for occupying the project for which theywere prepared, and not for the construction of any other project.DEMO PLAN GENERAL DEMOLITION NOTES: 1. Site to be fenced at a height between 72 and 84 inches using a chain link overlaid on the exterior with an opaque vinyl fence. 2. Topographic survey to be stamped and signed by a licensed surveyor (or civil engineer with license number 33965 or lower), as required per the Planning Division. 3. All debris shall be wet at time of handling to prevent dust. 4. Sewer line shall be capped. 5. All basement fills shall be clean and uniform. 6. Streets and sidewalks are to remain clean and free of any obstructions. 7. Plans are to be stamped and signed by a licensed engineer or architect. If plans done by a contractor, then contractor to sign and indicate his or her license number (legibly). 8. Pedestrian canopy protection required if demolition is within 10 feet of public sidewalk. 9. Erosion control devices shall be available on-site between October 15 and May 15. 10. Between October 15 and May 15, erosion control measures shall be in place at the end of each working day whenever the five-day probability of rain exceeds 30 percent. During the remainder of the year, they shall be in place at the end of the working day, whenever the daily rainfall probability exceeds 50 percent. 11. Temporary desilting basins, when required, shall be installed and maintained for the duration of the project. 12. If the demolition is proposed within the Coastal Zone and involves three or more dwelling units in one structure, or eleven or more dwelling units located in two or more structures, please meet with a planner to ensure compliance with the requirements in Chapter 20.34 (Conversion or Demolition of Affordable Housing) of the Zoning Code. 13. If the demolition is proposed within the Coastal Zone and within the Categorical Exclusion Order (CEO) Area, a CEO notice shall be sent to the Coastal Commission by a planner. The CEO notice becomes effective after 25 business days, unless called up for review by the Coastal Commission. Once effective, a demolition permit can be issued. Please meet with a planner to determine if property is eligible and to start the CEO notification process. 14. If the demolition is proposed within the Coastal Zone and not within the Categorical Exclusion Area, a Coastal Development Permit (CDP) is required. Please meet with a planner to discuss the application requirements for a CDP. ADDITIONAL NOTES: 1. Remove all existing landscape, planters, hardscape, wall, fences and existing concrete driveway where necessary per site plan. 2. Remove existing 3,000 sq.ft. 4 bedroom, 4 bathroom single family residence. 3. Protect existing wet and dry utilities on the lot. Notify gas company to shut off gas to property. PROJECT NORTHTRUE NORTH37°22 KITCHEN STAIRSDWRANGE OVENREF. DINING SEATING KITCHEN STAIRS DWRANGEOVENREF. DINING SEATING45'-0"LOT4'-0"SYSB26'-6" 7'-6"37'-0"4'-0"SYSB1'-0"BATH 1 4'-6"14'-6" 8'-6"5'-0"10'-0"10'-0" 30'-0" FYSB TRASH 30'-0"5'-0" FYSB 7'-6"4'-6"14'-6" 8'-6" 10'-0" 30'-0" FYSB 5'-0" FYSB 4'-0"SYSB4'-6"37'-0"4'-0"SYSBGARAGE 2 20'-0" GARAGE 1 CARPORT 1 CARPORT 2 ENTRY LAUNDRY 5'-0"10'-0"10'-0"7'-8"10'-4"7'-8"10'-4"35'-0" PANTRY PANTRY BATH 1LAUNDRY STORAGE TRASH STORAGE UP UP FIRE FIRE W/D 10'-0" 30'-0" FYSB 5'-0" FYSB ELEC ELEC 26'-6" 10'-0" 30'-0" 10'-0"16'-1"4'-10"3'-0"1'-0"16'-1"3'-0"1 2'-0"2'-0"5'-0" 20'-0" 35'-0"5'-0" W/D 5'-0"3'-6" MICRO. MICRO. 5'-0"3'-6" 20'-0" 20'-0"4'-6"25 16 1 25 16 16 56 16 56 39 39 2'-6"7.75"7.75"8.28FS8.53F S 6.18FS8.70FSENTRY 9.17 FF LIVING 9.17 FF LIVING 9.17 FF AA4.1AA4.1B A4.1 2 A2.1 1/4"=1'-0" SHEET NUMBER PLOT DATE: SCALE: 8.8.18R E S I D E N C EN E W P O R T B E A C H5 1 5 3 6 t h S T R E E Thudgins design group, inc.G U O laguna beach, ca, 92651 t: 949.322.7922 1107 south coast hwy e: info@hudginsdesign.com CDP SUB. #1 08.08.18 hudgins design group, inc, expressly reserves its common law copyright and other property rights in these drawings. These drawings are not to be reproduced, changed, or copied in any form or manner whatsoever nor are they to be assigned to any third party without first obtaining theexpressed written permission of hudgins design group, inc. The drawings and specifications remain the property of hudgins design group, inc. Copies of the drawings and specifications retained by the client may be utilized only for his or her use and for occupying the project for which theywere prepared, and not for the construction of any other project.LEVEL 1 FLOOR PLAN KEYNOTES MATERIALS LEGEND STONE FLOORING, PORTUGUESE LIMESTONESTN-1 WD-1 TRANSPARENT GLASSGLS-1 MTL-2 STN-2 TRANSPARENT TEMPERED GLASS, AT GUARDRAILSGLS-2 CON-1 INTEGRALLY COLORED SMOOTH TROWEL STUCCO, WHITESTUC PLANTING AREA - REFER TO LANDSCAPE PLANP/A (N) CONCRETE WALL BREAK METAL, PAINTED - 'KYNAR 500' TO MATCH WINDOWS WD-3 VEGETATION/LANDSCAPING PER LANDSCAPE PLANVEG (N) WALL TRASH STORAGE AREA, SCREENED FROM STREET A/C EQUIPMENT, SCREENED W/ SOUND ATTENUATION PER CITY AREA OF OPEN VOLUME - SEE AREA CALCS SHEET A1.2 OUTDOOR FIRE PIT W/ DRAINAGE, +18" A.F.F. PROPOSED MAILBOX LOCATION ASPHALT ROOF SHINGLES, CLASS A, DARK GRAY COLORASPH WOOD FLOORING / CEILING STONE VENEER, SILVER TRAVERTINE HARDSCAPE / PORCH / PATIO (N) SEAWALL EXTENSION PER 'SW' DRAWINGS PROPERTY LINE1 SETBACK ROOF - MIN. CLASS 'A' FIRE RATED BUILDING FOOTPRINT EDGE OF ROOF/ CEILING (ABV/ BLW/ BYD AS OCCURS) 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 EDGE OF WALL (ABV/ BLW/ BYD AS OCCURS) (E) WATER METER LOCATION (REF CIVIL & SURVEY DWGS) FAU - PROVIDE GAS S. O., POWER, AND VENTING AS REQ'D. BY MFGR. (CMC 904. 1) STRUCTURAL COLUMN / BEAM PER STRUCTURAL FF/ FS/ FG/ EG (ABOVE/ BELOW/ BEYOND AS OCCURS) (E) CURB/ EDGE OF PAVEMENT FIXED DATUM POINT/ BENCHMARK CONTINUOUS RECESSED STRIP DRAIN - SEE CIVIL DWG'S (E) GRADE (N) FINISH GRADE/ FINISH SURFACE GARAGE CENTERLINE OF RIGHT OF WAY WATER HEATER - TANK-LESS (ON DEMAND) WALL -MOUNT +44" MIN., VERIFY SIZE REQ'D. W/. MFGR. (PROVIDE GAS) DOOR/ WINDOW PER SCHEDULE (ABV/ BLW/ BYD AS OCCURS) WOOD DECK (ABV/ BLW/ BYD) O/ SLEEPERS O/ CONC BASE 42 43 EXTERIOR STAIRS/STEPS - REF. CIVIL DRAWINGS 44 (N) GATE - AS SELECTED 45 46 47 48 49 GARAGE DOOR & TRACK (ABV) - INSTALL PER MANUF. SPEC. 50 51 52 PROPOSED MAIN SERVICE PANEL, 400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION) - VERIFY LOCATION W/. SO. CA. EDISON 53 54 55 56 CABINETRY (N) DRIVEWAY PLANTING/SOFTSCAPE AREA - SEE LANDSCAPE PLANS PAVERS - SEE LANDSCAPE PLANS EXISTING / PROPOSED GAS METER LOCATION OUTLINE OF EXISTING STRUCTURE TO BE REMOVED/DEMOLISHED BBQ, PROVIDE GAS AND ELEC. PER OWNER BENCH, +18" A.F.F. (N) DECORATIVE CHIMNEY SHROUD MODEL S11 BY 'AMERICAN CHIMNEY SHROUD.' UL LISTING (MH30042) & WH LISTING (5091753). TERMINATE 2FT MINIMUM ABOVE BUILDING PER CRC R1003.9 ROOF CRICKET, BUILT-UP AS REQUIRED COUNTER, +36" A.F.F. ROOF DRAIN W/ OVERFLOW AND CONCEALED PIPES PER CPC TABLES 11-1 AND 11-2 57 58 ROOF RIDGE/ VALLEY 59 60 ROOF PARAPET COUNTER, +30" A.F.F. STEEL UTILITY DOOR, VERIFY LOUVER REQUIREMENT SKYLIGHT (ABV / BLW / BYD AS OCCURS) ICC-ES ESR 2415 61 RECESSED CURTAIN/SHADE TRACK, MOTORIZED W/ REMOTE 62 63 WOOD SIDING, 7" JAMES HARDIE PLANK, ARTISAN V-GROOVE KHAKI BROWN COLOR CONCRETE FLOORING/DECKING ADJACENT BUILDING PLANTER AREA COUNTER, +42" A.F.F. EXTERIOR SIDING, PER ELEVATIONS (E) UTILITY VAULT/BOX LOCATION (REF CIVIL & SURVEY DWGS) EXTERIOR GUARDRAIL, MIN HEIGHT +42" A.F.F. NOT USED DRAIN LINE, IN WALL/FROM ABV. REF. CIVIL DWGS. NOT USED (N) STAIRS W/ MAXIMUM RISER HEIGHT SHALL BE 7-3/4" AND A MINIMUM OF 4". MINIMUM TREAD DEPTH SHALL BE 10". PROVIDE ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT CANDLE (CBC 1205.4) 34"-38" HIGH GUARDRAIL/ HANDRAIL @ STAIR FRAMELESS TEMPERED/LAMINATED GLASS GUARDRAIL PER CBC 2407. INSTALL PER MANUF. SPECS, ICCES-ESR-3269 PROVIDE (N) FAU, HEAT PER CRC R303.9 GAS FIREPLACE - 'MONTIGO' - ANSI Z21.50 / CSA 2.22-2014 AND ANSI Z21.97 / CSA 2.41-2014. DIRECT VENT, SEALED COMBUSTION, FIXED TREMPERED GLASS FRONT MODEL R520. CERTIFICATE # 1455422 WD-2 WOOD SIDING, 2-3/4" VERTICAL RESYSTA, DARK GREY COLOR MTL-1 STANDING SEAM ZINC METAL ROOF, CLASS "A", DARK GREY W/ 16" CONTINUOUS PANS. 64 SETBACK AREA ALLOWED FOR MINOR STRUCTURES65 4 SIDED POLYGON USED TO ESTABLISH GRADE 66 FENCE / SITE WALL - 42" MAX. IN FRONT67 ADDITIONAL THIRD FLOOR SETBACK68 (E) FENCE / SITE WALL - 72" MAX. PROTECT IN PLACE. MTL-3 STEEL GUARDRAIL, PAINTED - 'KYNAR 500' TO MATCH WINDOWS MTL-4 METAL DOOR, PAINTED - 'KYNAR 500' PROJECT NORTHTRUE NORTH37°23 UP STAIRS STAIRS DNUPDN 30'-0" FYSB 5'-0" FYSB FIRE FIRE BATH 2 BATH 1 BATH 3 CLOSET CLOSETCLOSET LANDING BEDROOM 1 BATH 1 CLOSET BATH 2 BATH 3 BEDROOM 3 CLOSET BEDROOM 2 LANDING CLOSET 5'-0" FYSB 29'-7" 44 4'-0"SYSB37'-0"4'-0"SYSB6'-2"5'-10"6'-6"DECK DECK 6'-2"5'-10"6'-6"7'-6"4'-6"14'-6" 8'-11"26'-6" 5'-5"3'-6" 30'-0" FYSB 29'-7" 7'-6"4'-6"14'-6" 8'-11" 12'-1" 26'-6" 8'-9"8'-9"5'-5"3'-6"45'-0"LOT4'-0"SYSB37'-0"4'-0"SYSB1'-0"16'-1"4'-10"3'-0"1'-0"16'-1"3'-0"2'-6"2'-6"2'-6" 2'-6"2'-6"2'-6"12'-1"8'-9"8'-9" (12'-0" X 12'-0") (11'-5" X 13'-8") BEDROOM 2 (11'-5" X 13'-8") BEDROOM 3 (12'-0" X 12'-0") (12'-6" X 17'-8") BEDROOM 1 (12'-6" X 17'-8") 5'-0" 5'-0"8"5'-6"12'-6" 12'-6" 7'-0"6'-6"4'-0"9'-3"3'-2"4'-11"7'-0"6'-6"4'-0"9'-3"3'-2"4'-11"3'-3" 3'-3"3'-6"13'-2"1'-6"3'-6"13'-2"1'-6"16 44 16 5'-6"8"44 44 16 AA4.1AA4.1B A4.1 3'-0" 3'-0" 2 45 45 56 56 58 58 16 16 1 1 16 45 45 2% AVG. SLOPE 2% AVG. SLOPE 1 1 4" 4" A2.2 1/4"=1'-0" SHEET NUMBER PLOT DATE: SCALE: 8.8.18R E S I D E N C EN E W P O R T B E A C H5 1 5 3 6 t h S T R E E Thudgins design group, inc.G U O laguna beach, ca, 92651 t: 949.322.7922 1107 south coast hwy e: info@hudginsdesign.com CDP SUB. #1 08.08.18 hudgins design group, inc, expressly reserves its common law copyright and other property rights in these drawings. These drawings are not to be reproduced, changed, or copied in any form or manner whatsoever nor are they to be assigned to any third party without first obtaining theexpressed written permission of hudgins design group, inc. The drawings and specifications remain the property of hudgins design group, inc. Copies of the drawings and specifications retained by the client may be utilized only for his or her use and for occupying the project for which theywere prepared, and not for the construction of any other project.LEVEL 2 FLOOR PLAN KEYNOTES MATERIALS LEGEND STONE FLOORING, PORTUGUESE LIMESTONESTN-1 WD-1 TRANSPARENT GLASSGLS-1 MTL-2 STN-2 TRANSPARENT TEMPERED GLASS, AT GUARDRAILSGLS-2 CON-1 INTEGRALLY COLORED SMOOTH TROWEL STUCCO, WHITESTUC PLANTING AREA - REFER TO LANDSCAPE PLANP/A (N) CONCRETE WALL BREAK METAL, PAINTED - 'KYNAR 500' TO MATCH WINDOWS WD-3 VEGETATION/LANDSCAPING PER LANDSCAPE PLANVEG (N) WALL TRASH STORAGE AREA, SCREENED FROM STREET A/C EQUIPMENT, SCREENED W/ SOUND ATTENUATION PER CITY AREA OF OPEN VOLUME - SEE AREA CALCS SHEET A1.2 OUTDOOR FIRE PIT W/ DRAINAGE, +18" A.F.F. PROPOSED MAILBOX LOCATION ASPHALT ROOF SHINGLES, CLASS A, DARK GRAY COLORASPH WOOD FLOORING / CEILING STONE VENEER, SILVER TRAVERTINE HARDSCAPE / PORCH / PATIO (N) SEAWALL EXTENSION PER 'SW' DRAWINGS PROPERTY LINE1 SETBACK ROOF - MIN. CLASS 'A' FIRE RATED BUILDING FOOTPRINT EDGE OF ROOF/ CEILING (ABV/ BLW/ BYD AS OCCURS) 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 EDGE OF WALL (ABV/ BLW/ BYD AS OCCURS) (E) WATER METER LOCATION (REF CIVIL & SURVEY DWGS) FAU - PROVIDE GAS S. O., POWER, AND VENTING AS REQ'D. BY MFGR. (CMC 904. 1) STRUCTURAL COLUMN / BEAM PER STRUCTURAL FF/ FS/ FG/ EG (ABOVE/ BELOW/ BEYOND AS OCCURS) (E) CURB/ EDGE OF PAVEMENT FIXED DATUM POINT/ BENCHMARK CONTINUOUS RECESSED STRIP DRAIN - SEE CIVIL DWG'S (E) GRADE (N) FINISH GRADE/ FINISH SURFACE GARAGE CENTERLINE OF RIGHT OF WAY WATER HEATER - TANK-LESS (ON DEMAND) WALL -MOUNT +44" MIN., VERIFY SIZE REQ'D. W/. MFGR. (PROVIDE GAS) DOOR/ WINDOW PER SCHEDULE (ABV/ BLW/ BYD AS OCCURS) WOOD DECK (ABV/ BLW/ BYD) O/ SLEEPERS O/ CONC BASE 42 43 EXTERIOR STAIRS/STEPS - REF. CIVIL DRAWINGS 44 (N) GATE - AS SELECTED 45 46 47 48 49 GARAGE DOOR & TRACK (ABV) - INSTALL PER MANUF. SPEC. 50 51 52 PROPOSED MAIN SERVICE PANEL, 400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION) - VERIFY LOCATION W/. SO. CA. EDISON 53 54 55 56 CABINETRY (N) DRIVEWAY PLANTING/SOFTSCAPE AREA - SEE LANDSCAPE PLANS PAVERS - SEE LANDSCAPE PLANS EXISTING / PROPOSED GAS METER LOCATION OUTLINE OF EXISTING STRUCTURE TO BE REMOVED/DEMOLISHED BBQ, PROVIDE GAS AND ELEC. PER OWNER BENCH, +18" A.F.F. (N) DECORATIVE CHIMNEY SHROUD MODEL S11 BY 'AMERICAN CHIMNEY SHROUD.' UL LISTING (MH30042) & WH LISTING (5091753). TERMINATE 2FT MINIMUM ABOVE BUILDING PER CRC R1003.9 ROOF CRICKET, BUILT-UP AS REQUIRED COUNTER, +36" A.F.F. ROOF DRAIN W/ OVERFLOW AND CONCEALED PIPES PER CPC TABLES 11-1 AND 11-2 57 58 ROOF RIDGE/ VALLEY 59 60 ROOF PARAPET COUNTER, +30" A.F.F. STEEL UTILITY DOOR, VERIFY LOUVER REQUIREMENT SKYLIGHT (ABV / BLW / BYD AS OCCURS) ICC-ES ESR 2415 61 RECESSED CURTAIN/SHADE TRACK, MOTORIZED W/ REMOTE 62 63 WOOD SIDING, 7" JAMES HARDIE PLANK, ARTISAN V-GROOVE KHAKI BROWN COLOR CONCRETE FLOORING/DECKING ADJACENT BUILDING PLANTER AREA COUNTER, +42" A.F.F. EXTERIOR SIDING, PER ELEVATIONS (E) UTILITY VAULT/BOX LOCATION (REF CIVIL & SURVEY DWGS) EXTERIOR GUARDRAIL, MIN HEIGHT +42" A.F.F. NOT USED DRAIN LINE, IN WALL/FROM ABV. REF. CIVIL DWGS. NOT USED (N) STAIRS W/ MAXIMUM RISER HEIGHT SHALL BE 7-3/4" AND A MINIMUM OF 4". MINIMUM TREAD DEPTH SHALL BE 10". PROVIDE ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT CANDLE (CBC 1205.4) 34"-38" HIGH GUARDRAIL/ HANDRAIL @ STAIR FRAMELESS TEMPERED/LAMINATED GLASS GUARDRAIL PER CBC 2407. INSTALL PER MANUF. SPECS, ICCES-ESR-3269 PROVIDE (N) FAU, HEAT PER CRC R303.9 GAS FIREPLACE - 'MONTIGO' - ANSI Z21.50 / CSA 2.22-2014 AND ANSI Z21.97 / CSA 2.41-2014. DIRECT VENT, SEALED COMBUSTION, FIXED TREMPERED GLASS FRONT MODEL R520. CERTIFICATE # 1455422 WD-2 WOOD SIDING, 2-3/4" VERTICAL RESYSTA, DARK GREY COLOR MTL-1 STANDING SEAM ZINC METAL ROOF, CLASS "A", DARK GREY W/ 16" CONTINUOUS PANS. 64 SETBACK AREA ALLOWED FOR MINOR STRUCTURES65 4 SIDED POLYGON USED TO ESTABLISH GRADE 66 FENCE / SITE WALL - 42" MAX. IN FRONT67 ADDITIONAL THIRD FLOOR SETBACK68 (E) FENCE / SITE WALL - 72" MAX. PROTECT IN PLACE. MTL-3 STEEL GUARDRAIL, PAINTED - 'KYNAR 500' TO MATCH WINDOWS MTL-4 METAL DOOR, PAINTED - 'KYNAR 500' PROJECT NORTHTRUE NORTH37°24 STAIRS DN 30'-0" FYSB 5'-0" FYSB 15'-0" 3RD FLOOR ENCLOSED SQ.FT. SETBACK 15'-0" 3RD FLOOR ENCLOSED SQ.FT. SETBACK 4'-0"SYSB4'-0"SYSBOUTDOOR COVERED CABANA DINING VIEW DECKFIRE OPEN TO BELOW BONUS STAIRS DN OUTDOOR COVERED CABANA DINING VIEW DECK OPEN TO BELOW BONUS FIRE13'-10"1'-3"30'-0" FYSB 5'-0" FYSB 15'-0" 3RD FLOOR ENCLOSED SQ.FT. SETBACK 15'-0" 3RD FLOOR ENCLOSED SQ.FT. SETBACK 13'-9"11'-0" 44 45'-0"LOT4'-0"SYSB37'-0"4'-0"SYSB12'-4"8"5'-10"6'-0"3RD FLR.ENCLOSEDSETBACK9'-0"4'-10"4'-0"SYSB37'-0"4'-0"SYSB7'-8"13'-10"4'-10"12'-4"5'-10"6'-0"3RD FLR.ENCLOSEDSETBACK1'-3"13'-9"11'-0"9'-0" 7'-10"5'-11"6'-0"3RD FLR.ENCLOSEDSETBACK6'-0"3RD FLR.ENCLOSEDSETBACKDWICE DWICE REF REF WINE WINE MECH MECH4'-6"8'-10"3'-6"3'-0"7'-6"4'-6"2'-6"12'-0"3'-0" 3'-0"7'-6"4'-6"2'-6"12'-0"3'-0"5'-0"8'-10"3'-6"3'-6"8"3'-0"3'-0"2'-0"4'-6"8'-10"3'-6"2'-0" 16 44 16 44 16 44 2'-6" 2'-6"AA4.1AA4.1B A4.1 26 26 45 45 44 45 58 68 16 44 45 58 68 16 55 1 55 38 38 19 19 2 1 7'-10"5'-11" 16 16 16 16 A2.3 1/4"=1'-0" SHEET NUMBER PLOT DATE: SCALE: 8.8.18R E S I D E N C EN E W P O R T B E A C H5 1 5 3 6 t h S T R E E Thudgins design group, inc.G U O laguna beach, ca, 92651 t: 949.322.7922 1107 south coast hwy e: info@hudginsdesign.com CDP SUB. #1 08.08.18 hudgins design group, inc, expressly reserves its common law copyright and other property rights in these drawings. These drawings are not to be reproduced, changed, or copied in any form or manner whatsoever nor are they to be assigned to any third party without first obtaining theexpressed written permission of hudgins design group, inc. The drawings and specifications remain the property of hudgins design group, inc. Copies of the drawings and specifications retained by the client may be utilized only for his or her use and for occupying the project for which theywere prepared, and not for the construction of any other project.LEVEL 3 FLOOR PLAN KEYNOTES MATERIALS LEGEND STONE FLOORING, PORTUGUESE LIMESTONESTN-1 WD-1 TRANSPARENT GLASSGLS-1 MTL-2 STN-2 TRANSPARENT TEMPERED GLASS, AT GUARDRAILSGLS-2 CON-1 INTEGRALLY COLORED SMOOTH TROWEL STUCCO, WHITESTUC PLANTING AREA - REFER TO LANDSCAPE PLANP/A (N) CONCRETE WALL BREAK METAL, PAINTED - 'KYNAR 500' TO MATCH WINDOWS WD-3 VEGETATION/LANDSCAPING PER LANDSCAPE PLANVEG (N) WALL TRASH STORAGE AREA, SCREENED FROM STREET A/C EQUIPMENT, SCREENED W/ SOUND ATTENUATION PER CITY AREA OF OPEN VOLUME - SEE AREA CALCS SHEET A1.2 OUTDOOR FIRE PIT W/ DRAINAGE, +18" A.F.F. PROPOSED MAILBOX LOCATION ASPHALT ROOF SHINGLES, CLASS A, DARK GRAY COLORASPH WOOD FLOORING / CEILING STONE VENEER, SILVER TRAVERTINE HARDSCAPE / PORCH / PATIO (N) SEAWALL EXTENSION PER 'SW' DRAWINGS PROPERTY LINE1 SETBACK ROOF - MIN. CLASS 'A' FIRE RATED BUILDING FOOTPRINT EDGE OF ROOF/ CEILING (ABV/ BLW/ BYD AS OCCURS) 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 EDGE OF WALL (ABV/ BLW/ BYD AS OCCURS) (E) WATER METER LOCATION (REF CIVIL & SURVEY DWGS) FAU - PROVIDE GAS S. O., POWER, AND VENTING AS REQ'D. BY MFGR. (CMC 904. 1) STRUCTURAL COLUMN / BEAM PER STRUCTURAL FF/ FS/ FG/ EG (ABOVE/ BELOW/ BEYOND AS OCCURS) (E) CURB/ EDGE OF PAVEMENT FIXED DATUM POINT/ BENCHMARK CONTINUOUS RECESSED STRIP DRAIN - SEE CIVIL DWG'S (E) GRADE (N) FINISH GRADE/ FINISH SURFACE GARAGE CENTERLINE OF RIGHT OF WAY WATER HEATER - TANK-LESS (ON DEMAND) WALL -MOUNT +44" MIN., VERIFY SIZE REQ'D. W/. MFGR. (PROVIDE GAS) DOOR/ WINDOW PER SCHEDULE (ABV/ BLW/ BYD AS OCCURS) WOOD DECK (ABV/ BLW/ BYD) O/ SLEEPERS O/ CONC BASE 42 43 EXTERIOR STAIRS/STEPS - REF. CIVIL DRAWINGS 44 (N) GATE - AS SELECTED 45 46 47 48 49 GARAGE DOOR & TRACK (ABV) - INSTALL PER MANUF. SPEC. 50 51 52 PROPOSED MAIN SERVICE PANEL, 400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION) - VERIFY LOCATION W/. SO. CA. EDISON 53 54 55 56 CABINETRY (N) DRIVEWAY PLANTING/SOFTSCAPE AREA - SEE LANDSCAPE PLANS PAVERS - SEE LANDSCAPE PLANS EXISTING / PROPOSED GAS METER LOCATION OUTLINE OF EXISTING STRUCTURE TO BE REMOVED/DEMOLISHED BBQ, PROVIDE GAS AND ELEC. PER OWNER BENCH, +18" A.F.F. (N) DECORATIVE CHIMNEY SHROUD MODEL S11 BY 'AMERICAN CHIMNEY SHROUD.' UL LISTING (MH30042) & WH LISTING (5091753). TERMINATE 2FT MINIMUM ABOVE BUILDING PER CRC R1003.9 ROOF CRICKET, BUILT-UP AS REQUIRED COUNTER, +36" A.F.F. ROOF DRAIN W/ OVERFLOW AND CONCEALED PIPES PER CPC TABLES 11-1 AND 11-2 57 58 ROOF RIDGE/ VALLEY 59 60 ROOF PARAPET COUNTER, +30" A.F.F. STEEL UTILITY DOOR, VERIFY LOUVER REQUIREMENT SKYLIGHT (ABV / BLW / BYD AS OCCURS) ICC-ES ESR 2415 61 RECESSED CURTAIN/SHADE TRACK, MOTORIZED W/ REMOTE 62 63 WOOD SIDING, 7" JAMES HARDIE PLANK, ARTISAN V-GROOVE KHAKI BROWN COLOR CONCRETE FLOORING/DECKING ADJACENT BUILDING PLANTER AREA COUNTER, +42" A.F.F. EXTERIOR SIDING, PER ELEVATIONS (E) UTILITY VAULT/BOX LOCATION (REF CIVIL & SURVEY DWGS) EXTERIOR GUARDRAIL, MIN HEIGHT +42" A.F.F. NOT USED DRAIN LINE, IN WALL/FROM ABV. REF. CIVIL DWGS. NOT USED (N) STAIRS W/ MAXIMUM RISER HEIGHT SHALL BE 7-3/4" AND A MINIMUM OF 4". MINIMUM TREAD DEPTH SHALL BE 10". PROVIDE ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT CANDLE (CBC 1205.4) 34"-38" HIGH GUARDRAIL/ HANDRAIL @ STAIR FRAMELESS TEMPERED/LAMINATED GLASS GUARDRAIL PER CBC 2407. INSTALL PER MANUF. SPECS, ICCES-ESR-3269 PROVIDE (N) FAU, HEAT PER CRC R303.9 GAS FIREPLACE - 'MONTIGO' - ANSI Z21.50 / CSA 2.22-2014 AND ANSI Z21.97 / CSA 2.41-2014. DIRECT VENT, SEALED COMBUSTION, FIXED TREMPERED GLASS FRONT MODEL R520. CERTIFICATE # 1455422 WD-2 WOOD SIDING, 2-3/4" VERTICAL RESYSTA, DARK GREY COLOR MTL-1 STANDING SEAM ZINC METAL ROOF, CLASS "A", DARK GREY W/ 16" CONTINUOUS PANS. 64 SETBACK AREA ALLOWED FOR MINOR STRUCTURES65 4 SIDED POLYGON USED TO ESTABLISH GRADE 66 FENCE / SITE WALL - 42" MAX. IN FRONT67 ADDITIONAL THIRD FLOOR SETBACK68 (E) FENCE / SITE WALL - 72" MAX. PROTECT IN PLACE. MTL-3 STEEL GUARDRAIL, PAINTED - 'KYNAR 500' TO MATCH WINDOWS MTL-4 METAL DOOR, PAINTED - 'KYNAR 500' PROJECT NORTHTRUE NORTH37°25 30'-0" FYSB 5'-0" FYSB 15'-0" 3RD FLOOR ENCLOSED SQ.FT. SETBACK 15'-0" 3RD FLOOR ENCLOSED SQ.FT. SETBACK 4'-0"SYSB4'-0"SYSBOUTDOOR DINING VIEW DECKFIRE OUTDOOR DINING VIEW DECK FIRE13'-10"10"30'-0" FYSB 5'-0" FYSB 15'-0" 3RD FLOOR ENCLOSED SQ.FT. SETBACK 15'-0" 3RD FLOOR ENCLOSED SQ.FT. SETBACK 14'-2"11'-0" 44 45'-0"LOT4'-0"SYSB37'-0"4'-0"SYSB12'-4"8"5'-10"6'-0"3RD FLR.ENCLOSEDSETBACK9'-0"4'-10"4'-0"SYSB37'-0"4'-0"SYSB7'-8"13'-10"4'-10"12'-4"5'-10"6'-0"3RD FLR.ENCLOSEDSETBACK8'-3"5'-11" 10"14'-2"11'-0"9'-0" 8'-3"5'-11"6'-0"3RD FLR.ENCLOSEDSETBACK6'-0"3RD FLR.ENCLOSEDSETBACKMECH MECH4'-6"8'-10"3'-6"3'-0"7'-6"4'-6"2'-6"12'-0"3'-0" 3'-0"7'-6"4'-6"2'-6"12'-0"3'-0"5'-0"8'-10"3'-6"3'-6"8"3'-0"3'-0"2'-0"4'-6"8'-10"3'-6"2'-0" 16 44 16 44 16 44 2'-6" 2'-6"AA4.1AA4.1B A4.1 38.00 TR38.00 TR38.00 T R38.00 TR36.33 TR36.33 TR36.33 TR36.33 TR36.33 TR36.33 TR3:12SLOPE3:12SLOPE3:12SLOPE3:12SLOPEMTL-5 MTL-5 MTL-5 MTL-5 48 48 48 HT. CERT. REQ'D HT. CERT. REQ'D HT. CERT. REQ'D HT. CERT. REQ'D 32.17 TWHT. CERT. REQ'D 32.17 TWHT. CERT. REQ'D 32.17 TWHT. CERT. REQ'D 32.17 TWHT. CERT. REQ'D 32.17 TWHT. CERT. REQ'D 32.17 TWHT. CERT. REQ'D 16 55 55 1 1 1 2 2 A2.4 1/4"=1'-0" SHEET NUMBER PLOT DATE: SCALE: 8.8.18R E S I D E N C EN E W P O R T B E A C H5 1 5 3 6 t h S T R E E Thudgins design group, inc.G U O laguna beach, ca, 92651 t: 949.322.7922 1107 south coast hwy e: info@hudginsdesign.com CDP SUB. #1 08.08.18 hudgins design group, inc, expressly reserves its common law copyright and other property rights in these drawings. These drawings are not to be reproduced, changed, or copied in any form or manner whatsoever nor are they to be assigned to any third party without first obtaining theexpressed written permission of hudgins design group, inc. The drawings and specifications remain the property of hudgins design group, inc. Copies of the drawings and specifications retained by the client may be utilized only for his or her use and for occupying the project for which theywere prepared, and not for the construction of any other project.ROOF PLAN KEYNOTES MATERIALS LEGEND STONE FLOORING, PORTUGUESE LIMESTONESTN-1 WD-1 TRANSPARENT GLASSGLS-1 MTL-2 STN-2 TRANSPARENT TEMPERED GLASS, AT GUARDRAILSGLS-2 CON-1 INTEGRALLY COLORED SMOOTH TROWEL STUCCO, WHITESTUC PLANTING AREA - REFER TO LANDSCAPE PLANP/A (N) CONCRETE WALL BREAK METAL, PAINTED - 'KYNAR 500' TO MATCH WINDOWS WD-3 VEGETATION/LANDSCAPING PER LANDSCAPE PLANVEG (N) WALL TRASH STORAGE AREA, SCREENED FROM STREET A/C EQUIPMENT, SCREENED W/ SOUND ATTENUATION PER CITY AREA OF OPEN VOLUME - SEE AREA CALCS SHEET A1.2 OUTDOOR FIRE PIT W/ DRAINAGE, +18" A.F.F. PROPOSED MAILBOX LOCATION ASPHALT ROOF SHINGLES, CLASS A, DARK GRAY COLORASPH WOOD FLOORING / CEILING STONE VENEER, SILVER TRAVERTINE HARDSCAPE / PORCH / PATIO (N) SEAWALL EXTENSION PER 'SW' DRAWINGS PROPERTY LINE1 SETBACK ROOF - MIN. CLASS 'A' FIRE RATED BUILDING FOOTPRINT EDGE OF ROOF/ CEILING (ABV/ BLW/ BYD AS OCCURS) 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 EDGE OF WALL (ABV/ BLW/ BYD AS OCCURS) (E) WATER METER LOCATION (REF CIVIL & SURVEY DWGS) FAU - PROVIDE GAS S. O., POWER, AND VENTING AS REQ'D. BY MFGR. (CMC 904. 1) STRUCTURAL COLUMN / BEAM PER STRUCTURAL FF/ FS/ FG/ EG (ABOVE/ BELOW/ BEYOND AS OCCURS) (E) CURB/ EDGE OF PAVEMENT FIXED DATUM POINT/ BENCHMARK CONTINUOUS RECESSED STRIP DRAIN - SEE CIVIL DWG'S (E) GRADE (N) FINISH GRADE/ FINISH SURFACE GARAGE CENTERLINE OF RIGHT OF WAY WATER HEATER - TANK-LESS (ON DEMAND) WALL -MOUNT +44" MIN., VERIFY SIZE REQ'D. W/. MFGR. (PROVIDE GAS) DOOR/ WINDOW PER SCHEDULE (ABV/ BLW/ BYD AS OCCURS) WOOD DECK (ABV/ BLW/ BYD) O/ SLEEPERS O/ CONC BASE 42 43 EXTERIOR STAIRS/STEPS - REF. CIVIL DRAWINGS 44 (N) GATE - AS SELECTED 45 46 47 48 49 GARAGE DOOR & TRACK (ABV) - INSTALL PER MANUF. SPEC. 50 51 52 PROPOSED MAIN SERVICE PANEL, 400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION) - VERIFY LOCATION W/. SO. CA. EDISON 53 54 55 56 CABINETRY (N) DRIVEWAY PLANTING/SOFTSCAPE AREA - SEE LANDSCAPE PLANS PAVERS - SEE LANDSCAPE PLANS EXISTING / PROPOSED GAS METER LOCATION OUTLINE OF EXISTING STRUCTURE TO BE REMOVED/DEMOLISHED BBQ, PROVIDE GAS AND ELEC. PER OWNER BENCH, +18" A.F.F. (N) DECORATIVE CHIMNEY SHROUD MODEL S11 BY 'AMERICAN CHIMNEY SHROUD.' UL LISTING (MH30042) & WH LISTING (5091753). TERMINATE 2FT MINIMUM ABOVE BUILDING PER CRC R1003.9 ROOF CRICKET, BUILT-UP AS REQUIRED COUNTER, +36" A.F.F. ROOF DRAIN W/ OVERFLOW AND CONCEALED PIPES PER CPC TABLES 11-1 AND 11-2 57 58 ROOF RIDGE/ VALLEY 59 60 ROOF PARAPET COUNTER, +30" A.F.F. STEEL UTILITY DOOR, VERIFY LOUVER REQUIREMENT SKYLIGHT (ABV / BLW / BYD AS OCCURS) ICC-ES ESR 2415 61 RECESSED CURTAIN/SHADE TRACK, MOTORIZED W/ REMOTE 62 63 WOOD SIDING, 7" JAMES HARDIE PLANK, ARTISAN V-GROOVE KHAKI BROWN COLOR CONCRETE FLOORING/DECKING ADJACENT BUILDING PLANTER AREA COUNTER, +42" A.F.F. EXTERIOR SIDING, PER ELEVATIONS (E) UTILITY VAULT/BOX LOCATION (REF CIVIL & SURVEY DWGS) EXTERIOR GUARDRAIL, MIN HEIGHT +42" A.F.F. NOT USED DRAIN LINE, IN WALL/FROM ABV. REF. CIVIL DWGS. NOT USED (N) STAIRS W/ MAXIMUM RISER HEIGHT SHALL BE 7-3/4" AND A MINIMUM OF 4". MINIMUM TREAD DEPTH SHALL BE 10". PROVIDE ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT CANDLE (CBC 1205.4) 34"-38" HIGH GUARDRAIL/ HANDRAIL @ STAIR FRAMELESS TEMPERED/LAMINATED GLASS GUARDRAIL PER CBC 2407. INSTALL PER MANUF. SPECS, ICCES-ESR-3269 PROVIDE (N) FAU, HEAT PER CRC R303.9 GAS FIREPLACE - 'MONTIGO' - ANSI Z21.50 / CSA 2.22-2014 AND ANSI Z21.97 / CSA 2.41-2014. DIRECT VENT, SEALED COMBUSTION, FIXED TREMPERED GLASS FRONT MODEL R520. CERTIFICATE # 1455422 WD-2 WOOD SIDING, 2-3/4" VERTICAL RESYSTA, DARK GREY COLOR MTL-1 STANDING SEAM ZINC METAL ROOF, CLASS "A", DARK GREY W/ 16" CONTINUOUS PANS. 64 SETBACK AREA ALLOWED FOR MINOR STRUCTURES65 4 SIDED POLYGON USED TO ESTABLISH GRADE 66 FENCE / SITE WALL - 42" MAX. IN FRONT67 ADDITIONAL THIRD FLOOR SETBACK68 (E) FENCE / SITE WALL - 72" MAX. PROTECT IN PLACE. MTL-3 STEEL GUARDRAIL, PAINTED - 'KYNAR 500' TO MATCH WINDOWS MTL-4 METAL DOOR, PAINTED - 'KYNAR 500' PROJECT NORTHTRUE NORTH37°26 19.08' LEVEL 2 28.67' LEVEL 3 38.00' T.O.R. MAX. ALLOWED 9.17' LEVEL 1 19.08' LEVEL 2 28.67' LEVEL 3 WD-1 STUC WD-2 WD-1 GLS-1 STUC GLS-1 MTL-1 STUC MTL-2 STUC GLS-1 WD-1 GLS-1 MTL-1 STN-2 GLS-1 MTL-1 MTL-1 GLS-1 MTL-1 GLS-2 WD-1 MTL-1 STUC STUC WD-1 GLS-1 GLS-2 GLS-1 MTL-1 MTL-1 32.17 TW32.17 TW33.00' T.O.R. MAX. ALLOWED FLAT ROOF 44 55 44 45 58 58 2 2 1 1 66 29 8 8 38 32 10.61' TW28'-10"9'-11"9'-7"9'-4"3'-6"23'-10"1'-8"3'-0" 35 36.33 TR36.33 TR38.00 TR38.00 TRHT. CERT. REQ'D HT. CERT. REQ'D HT. CERT. REQ'D HT. CERT. REQ'D 44 32.17 TW42" MINABV. F.F.42" MINABV. F.F.42" MINABV. F.F.28 36 STUC 38.00' T.O.R. MAX. 33.00' T.O.R. MAX. ALLOWED FLAT ROOF ALLOWED SLOPE ROOF 52 52 52 52 9.17' LEVEL 1 19.08' LEVEL 2 28.67' LEVEL 3 19.08' LEVEL 2 28.67' LEVEL 3 38.00' T.O.R. MAX. WD-1 STUC WD-2 WD-1 GLS-1 STUC GLS-1 MTL-1 STUC MTL-2 STUC GLS-1 WD-1 GLS-1 STN-2 GLS-1 MTL-1 MTL-1 GLS-1 MTL-1 GLS-2 WD-1 MTL-1 STUC STUC WD-1 GLS-1 GLS-2 GLS-1 MTL-1 MTL-1 MTL-1 6 44 45 44 6 32.17 TW32.17 TW33.00' T.O.R. MAX. 8 29 8 2 1 2 1 67 3210.61' TW28'-10"9'-11"9'-7"9'-4"3'-6"23'-10"3'-6"3'-6"1'-8"3'-0" 38 3536.33 TR36.33 TR38.00 TR38.00 TR44 55 HT. CERT. REQ'D HT. CERT. REQ'D HT. CERT. REQ'D HT. CERT. REQ'D ALLOWED FLAT ROOF ALLOWED SLOPE ROOF 38.00' T.O.R. MAX. 33.00' T.O.R. MAX. ALLOWED FLAT ROOF ALLOWED SLOPE ROOF 52 52 52 52 28 A3.1 1/4"=1'-0" SHEET NUMBER PLOT DATE: SCALE: 9.18.18R E S I D E N C EN E W P O R T B E A C H5 1 5 3 6 t h S T R E E T1 hudgins design group, inc.G U O laguna beach, ca, 92651 t: 949.322.7922 1107 south coast hwy e: info@hudginsdesign.com CDP SUB. #2 09.18.18 hudgins design group, inc, expressly reserves its common law copyright and other property rights in these drawings. These drawings are not to be reproduced, changed, or copied in any form or manner whatsoever nor are they to be assigned to any third party without first obtaining theexpressed written permission of hudgins design group, inc. The drawings and specifications remain the property of hudgins design group, inc. Copies of the drawings and specifications retained by the client may be utilized only for his or her use and for occupying the project for which theywere prepared, and not for the construction of any other project.CDP SUB. #1 08.08.18 WEST ELEVATION KEYNOTES MATERIALS LEGEND STONE FLOORING, PORTUGUESE LIMESTONESTN-1 WD-1 TRANSPARENT GLASSGLS-1 MTL-2 STN-2 TRANSPARENT TEMPERED GLASS, AT GUARDRAILSGLS-2 CON-1 INTEGRALLY COLORED SMOOTH TROWEL STUCCO, WHITESTUC PLANTING AREA - REFER TO LANDSCAPE PLANP/A (N) CONCRETE WALL BREAK METAL, PAINTED - 'KYNAR 500' TO MATCH WINDOWS WD-3 VEGETATION/LANDSCAPING PER LANDSCAPE PLANVEG (N) WALL TRASH STORAGE AREA, SCREENED FROM STREET A/C EQUIPMENT, SCREENED W/ SOUND ATTENUATION PER CITY AREA OF OPEN VOLUME - SEE AREA CALCS SHEET A1.2 OUTDOOR FIRE PIT W/ DRAINAGE, +18" A.F.F. PROPOSED MAILBOX LOCATION ASPHALT ROOF SHINGLES, CLASS A, DARK GRAY COLORASPH WOOD FLOORING / CEILING STONE VENEER, SILVER TRAVERTINE HARDSCAPE / PORCH / PATIO (N) SEAWALL EXTENSION PER 'SW' DRAWINGS PROPERTY LINE1 SETBACK ROOF - MIN. CLASS 'A' FIRE RATED BUILDING FOOTPRINT EDGE OF ROOF/ CEILING (ABV/ BLW/ BYD AS OCCURS) 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 EDGE OF WALL (ABV/ BLW/ BYD AS OCCURS) (E) WATER METER LOCATION (REF CIVIL & SURVEY DWGS) FAU - PROVIDE GAS S. O., POWER, AND VENTING AS REQ'D. BY MFGR. (CMC 904. 1) STRUCTURAL COLUMN / BEAM PER STRUCTURAL FF/ FS/ FG/ EG (ABOVE/ BELOW/ BEYOND AS OCCURS) (E) CURB/ EDGE OF PAVEMENT FIXED DATUM POINT/ BENCHMARK CONTINUOUS RECESSED STRIP DRAIN - SEE CIVIL DWG'S (E) GRADE (N) FINISH GRADE/ FINISH SURFACE GARAGE CENTERLINE OF RIGHT OF WAY WATER HEATER - TANK-LESS (ON DEMAND) WALL -MOUNT +44" MIN., VERIFY SIZE REQ'D. W/. MFGR. (PROVIDE GAS) DOOR/ WINDOW PER SCHEDULE (ABV/ BLW/ BYD AS OCCURS) WOOD DECK (ABV/ BLW/ BYD) O/ SLEEPERS O/ CONC BASE 42 43 EXTERIOR STAIRS/STEPS - REF. CIVIL DRAWINGS 44 (N) GATE - AS SELECTED 45 46 47 48 49 GARAGE DOOR & TRACK (ABV) - INSTALL PER MANUF. SPEC. 50 51 52 PROPOSED MAIN SERVICE PANEL, 400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION) - VERIFY LOCATION W/. SO. CA. EDISON 53 54 55 56 CABINETRY (N) DRIVEWAY PLANTING/SOFTSCAPE AREA - SEE LANDSCAPE PLANS PAVERS - SEE LANDSCAPE PLANS EXISTING / PROPOSED GAS METER LOCATION OUTLINE OF EXISTING STRUCTURE TO BE REMOVED/DEMOLISHED BBQ, PROVIDE GAS AND ELEC. PER OWNER BENCH, +18" A.F.F. (N) DECORATIVE CHIMNEY SHROUD MODEL S11 BY 'AMERICAN CHIMNEY SHROUD.' UL LISTING (MH30042) & WH LISTING (5091753). TERMINATE 2FT MINIMUM ABOVE BUILDING PER CRC R1003.9 ROOF CRICKET, BUILT-UP AS REQUIRED COUNTER, +36" A.F.F. ROOF DRAIN W/ OVERFLOW AND CONCEALED PIPES PER CPC TABLES 11-1 AND 11-2 57 58 ROOF RIDGE/ VALLEY 59 60 ROOF PARAPET COUNTER, +30" A.F.F. STEEL UTILITY DOOR, VERIFY LOUVER REQUIREMENT SKYLIGHT (ABV / BLW / BYD AS OCCURS) ICC-ES ESR 2415 61 RECESSED CURTAIN/SHADE TRACK, MOTORIZED W/ REMOTE 62 63 WOOD SIDING, 7" JAMES HARDIE PLANK, ARTISAN V-GROOVE KHAKI BROWN COLOR CONCRETE FLOORING/DECKING ADJACENT BUILDING PLANTER AREA COUNTER, +42" A.F.F. EXTERIOR SIDING, PER ELEVATIONS (E) UTILITY VAULT/BOX LOCATION (REF CIVIL & SURVEY DWGS) EXTERIOR GUARDRAIL, MIN HEIGHT +42" A.F.F. ROOF EAVE PROJECTION, 30" MAX INTO SETBACKS DRAIN LINE, IN WALL/FROM ABV. REF. CIVIL DWGS. NOT USED (N) STAIRS W/ MAXIMUM RISER HEIGHT SHALL BE 7-3/4" AND A MINIMUM OF 4". MINIMUM TREAD DEPTH SHALL BE 10". PROVIDE ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT CANDLE (CBC 1205.4) 34"-38" HIGH GUARDRAIL/ HANDRAIL @ STAIR FRAMELESS TEMPERED/LAMINATED GLASS GUARDRAIL PER CBC 2407. INSTALL PER MANUF. SPECS, ICCES-ESR-3269 PROVIDE (N) FAU, HEAT PER CRC R303.9 GAS FIREPLACE - 'MONTIGO' - ANSI Z21.50 / CSA 2.22-2014 AND ANSI Z21.97 / CSA 2.41-2014. DIRECT VENT, SEALED COMBUSTION, FIXED TREMPERED GLASS FRONT MODEL R520. CERTIFICATE # 1455422 WD-2 WOOD SIDING, 2-3/4" VERTICAL RESYSTA, DARK GREY COLOR MTL-1 STANDING SEAM ZINC METAL ROOF, CLASS "A", DARK GREY W/ 16" CONTINUOUS PANS. 64 SETBACK AREA ALLOWED FOR MINOR STRUCTURES65 4 SIDED POLYGON USED TO ESTABLISH GRADE 66 FENCE / SITE WALL - 42" MAX. IN FRONT67 ADDITIONAL THIRD FLOOR SETBACK68 (E) FENCE / SITE WALL - 72" MAX. PROTECT IN PLACE. MTL-3 STEEL GUARDRAIL, PAINTED - 'KYNAR 500' TO MATCH WINDOWS MTL-4 METAL DOOR, PAINTED - 'KYNAR 500' EAST ELEVATION 1 1 1 1 1 1 1 1 1 1 1 1 27 9.17' LEVEL 1 19.08' LEVEL 2 28.67' LEVEL 3 38.00' T.O.R. MAX. ALLOWED SLOPED ROOF 9.17' LEVEL 1 19.08' LEVEL 2 28.67' LEVEL 3 38.00' T.O.R. MAX. ALLOWED STUC MTL-1 GLS-2 STN-2 STUC MTL-1 STN-2 GLS-1 GLS-2 STUC MTL-1 STN-2 GLS-1 STUC MTL-1 GLS-2 STN-2 STUC MTL-1 STN-2 GLS-1 GLS-2 STUC MTL-1 STN-2 GLS-1 STUC STN-2 GLS-1 44 44 58 44 44 58 33.00' T.O.R. MAX. ALLOWED FLAT ROOF 33.00' T.O.R. MAX. ALLOWED FLAT ROOF 123 123 38.00 TR38.00 TR32.17 TW32.17 TW32.17 TW1 1 2 2 88 38 38 10.13' TW10.61' TW10.61' TW28'-10"9'-11"9'-7"9'-4"3'-6"23'-10"3'-6"36.33 TR36.33 TR36.33 TRHT. CERT. REQ'D 42" MINABV. F.F.42" MINABV. F.F.42" MINABV. F.F.42" MINABV. F.F.HT. CERT. REQ'D HT. CERT. REQ'D HT. CERT. REQ'D 52 52 52 52 GLS-1 STUC WD-1 STUC GLS-1 WD-2 GLS-2 STUC WD-1 GLS-1 STUC WD-1 STUC GLS-1 WD-2 GLS-2 STUC WD-1 STUC MTL-3 WD-2 STUC MTL-4 9.17' LEVEL 1 19.08' LEVEL 2 28.67' LEVEL 3 38.00' T.O.R. MAX. ALLOWED 9.17' LEVEL 1 19.08' LEVEL 2 28.67' LEVEL 3 38.00' T.O.R. MAX. ALLOWED 44 STUC 38.00 TR38.00 TR32.17 TW32.17 TW33.00' T.O.R. MAX. ALLOWED FLAT ROOF33.00' T.O.R. MAX. ALLOWED FLAT ROOF 44 12 7 29 66 1 2 44 29 66 2 1 44 44 10.13 (E)TW10.23 (E)TW28'-10"9'-11"9'-7"9'-4"3'-6"3'-6"23'-10"36.33 TR36.33 TR36.33 TRHT. CERT. REQ'D HT. CERT. REQ'D HT. CERT. REQ'D 4545 14 52 52 A3.2 1/4"=1'-0" SHEET NUMBER PLOT DATE: SCALE: 9.18.18R E S I D E N C EN E W P O R T B E A C H5 1 5 3 6 t h S T R E E T1 hudgins design group, inc.G U O laguna beach, ca, 92651 t: 949.322.7922 1107 south coast hwy e: info@hudginsdesign.com CDP SUB. #2 09.18.18 hudgins design group, inc, expressly reserves its common law copyright and other property rights in these drawings. These drawings are not to be reproduced, changed, or copied in any form or manner whatsoever nor are they to be assigned to any third party without first obtaining theexpressed written permission of hudgins design group, inc. The drawings and specifications remain the property of hudgins design group, inc. Copies of the drawings and specifications retained by the client may be utilized only for his or her use and for occupying the project for which theywere prepared, and not for the construction of any other project.CDP SUB. #1 08.08.18 NORTH ELEVATION KEYNOTES MATERIALS LEGEND STONE FLOORING, PORTUGUESE LIMESTONESTN-1 WD-1 TRANSPARENT GLASSGLS-1 MTL-2 STN-2 TRANSPARENT TEMPERED GLASS, AT GUARDRAILSGLS-2 CON-1 INTEGRALLY COLORED SMOOTH TROWEL STUCCO, WHITESTUC PLANTING AREA - REFER TO LANDSCAPE PLANP/A (N) CONCRETE WALL BREAK METAL, PAINTED - 'KYNAR 500' TO MATCH WINDOWS WD-3 VEGETATION/LANDSCAPING PER LANDSCAPE PLANVEG (N) WALL TRASH STORAGE AREA, SCREENED FROM STREET A/C EQUIPMENT, SCREENED W/ SOUND ATTENUATION PER CITY AREA OF OPEN VOLUME - SEE AREA CALCS SHEET A1.2 OUTDOOR FIRE PIT W/ DRAINAGE, +18" A.F.F. PROPOSED MAILBOX LOCATION ASPHALT ROOF SHINGLES, CLASS A, DARK GRAY COLORASPH WOOD FLOORING / CEILING STONE VENEER, SILVER TRAVERTINE HARDSCAPE / PORCH / PATIO (N) SEAWALL EXTENSION PER 'SW' DRAWINGS PROPERTY LINE1 SETBACK ROOF - MIN. CLASS 'A' FIRE RATED BUILDING FOOTPRINT EDGE OF ROOF/ CEILING (ABV/ BLW/ BYD AS OCCURS) 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 EDGE OF WALL (ABV/ BLW/ BYD AS OCCURS) (E) WATER METER LOCATION (REF CIVIL & SURVEY DWGS) FAU - PROVIDE GAS S. O., POWER, AND VENTING AS REQ'D. BY MFGR. (CMC 904. 1) STRUCTURAL COLUMN / BEAM PER STRUCTURAL FF/ FS/ FG/ EG (ABOVE/ BELOW/ BEYOND AS OCCURS) (E) CURB/ EDGE OF PAVEMENT FIXED DATUM POINT/ BENCHMARK CONTINUOUS RECESSED STRIP DRAIN - SEE CIVIL DWG'S (E) GRADE (N) FINISH GRADE/ FINISH SURFACE GARAGE CENTERLINE OF RIGHT OF WAY WATER HEATER - TANK-LESS (ON DEMAND) WALL -MOUNT +44" MIN., VERIFY SIZE REQ'D. W/. MFGR. (PROVIDE GAS) DOOR/ WINDOW PER SCHEDULE (ABV/ BLW/ BYD AS OCCURS) WOOD DECK (ABV/ BLW/ BYD) O/ SLEEPERS O/ CONC BASE 42 43 EXTERIOR STAIRS/STEPS - REF. CIVIL DRAWINGS 44 (N) GATE - AS SELECTED 45 46 47 48 49 GARAGE DOOR & TRACK (ABV) - INSTALL PER MANUF. SPEC. 50 51 52 PROPOSED MAIN SERVICE PANEL, 400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION) - VERIFY LOCATION W/. SO. CA. EDISON 53 54 55 56 CABINETRY (N) DRIVEWAY PLANTING/SOFTSCAPE AREA - SEE LANDSCAPE PLANS PAVERS - SEE LANDSCAPE PLANS EXISTING / PROPOSED GAS METER LOCATION OUTLINE OF EXISTING STRUCTURE TO BE REMOVED/DEMOLISHED BBQ, PROVIDE GAS AND ELEC. PER OWNER BENCH, +18" A.F.F. (N) DECORATIVE CHIMNEY SHROUD MODEL S11 BY 'AMERICAN CHIMNEY SHROUD.' UL LISTING (MH30042) & WH LISTING (5091753). TERMINATE 2FT MINIMUM ABOVE BUILDING PER CRC R1003.9 ROOF CRICKET, BUILT-UP AS REQUIRED COUNTER, +36" A.F.F. ROOF DRAIN W/ OVERFLOW AND CONCEALED PIPES PER CPC TABLES 11-1 AND 11-2 57 58 ROOF RIDGE/ VALLEY 59 60 ROOF PARAPET COUNTER, +30" A.F.F. STEEL UTILITY DOOR, VERIFY LOUVER REQUIREMENT SKYLIGHT (ABV / BLW / BYD AS OCCURS) ICC-ES ESR 2415 61 RECESSED CURTAIN/SHADE TRACK, MOTORIZED W/ REMOTE 62 63 WOOD SIDING, 7" JAMES HARDIE PLANK, ARTISAN V-GROOVE KHAKI BROWN COLOR CONCRETE FLOORING/DECKING ADJACENT BUILDING PLANTER AREA COUNTER, +42" A.F.F. EXTERIOR SIDING, PER ELEVATIONS (E) UTILITY VAULT/BOX LOCATION (REF CIVIL & SURVEY DWGS) EXTERIOR GUARDRAIL, MIN HEIGHT +42" A.F.F. ROOF EAVE PROJECTION, 30" MAX INTO SETBACKS DRAIN LINE, IN WALL/FROM ABV. REF. CIVIL DWGS. NOT USED (N) STAIRS W/ MAXIMUM RISER HEIGHT SHALL BE 7-3/4" AND A MINIMUM OF 4". MINIMUM TREAD DEPTH SHALL BE 10". PROVIDE ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT CANDLE (CBC 1205.4) 34"-38" HIGH GUARDRAIL/ HANDRAIL @ STAIR FRAMELESS TEMPERED/LAMINATED GLASS GUARDRAIL PER CBC 2407. INSTALL PER MANUF. SPECS, ICCES-ESR-3269 PROVIDE (N) FAU, HEAT PER CRC R303.9 GAS FIREPLACE - 'MONTIGO' - ANSI Z21.50 / CSA 2.22-2014 AND ANSI Z21.97 / CSA 2.41-2014. DIRECT VENT, SEALED COMBUSTION, FIXED TREMPERED GLASS FRONT MODEL R520. CERTIFICATE # 1455422 WD-2 WOOD SIDING, 2-3/4" VERTICAL RESYSTA, DARK GREY COLOR MTL-1 STANDING SEAM ZINC METAL ROOF, CLASS "A", DARK GREY W/ 16" CONTINUOUS PANS. 64 SETBACK AREA ALLOWED FOR MINOR STRUCTURES65 4 SIDED POLYGON USED TO ESTABLISH GRADE 66 FENCE / SITE WALL - 42" MAX. IN FRONT67 ADDITIONAL THIRD FLOOR SETBACK68 (E) FENCE / SITE WALL - 72" MAX. PROTECT IN PLACE. MTL-3 STEEL GUARDRAIL, PAINTED - 'KYNAR 500' TO MATCH WINDOWS MTL-4 METAL DOOR, PAINTED - 'KYNAR 500' SOUTH ELEVATION 1 1 1 1 1 1 1 1 28 19.08' LEVEL 2 28.67' LEVEL 3 38.00' T.O.R. MAX. ALLOWED SLOPED ROOF 9.17' LEVEL 1 19.08' LEVEL 2 28.67' LEVEL 3 33.00' T.O.R. MAX. ALLOWED FLAT ROOF 28'-10"9'-11"9'-7"9'-4"23'-10"1 1 2 2 44 12 44 35 44 44 32 3'-0" BED 1 1'-8"38 38.00 TR32.17 TW31.67 TW32.17 TW44 6 42 8'-10"8'-6"8'-0"VARIES9'-4"9'-9"BED 3 GARAGE BONUS BED 2STAIR/ LANDINGCLOSETBATH 1 LIVING/ DINING KITCHEN WD-1 WD-1 WD-2 WD-1STUC STUC MTL-5 WD-1 STN-2 STUC WD-1 38 38.00 TRHT. CERT. REQ'D HT. CERT. REQ'D HT. CERT. REQ'DHT. CERT. REQ'D 19 45 14 45 28 36 36 42" MINABV. F.F.42" MINABV. F.F.38.00' T.O.R. MAX. 33.00' T.O.R. MAX. ALLOWED FLAT ROOF ALLOWED SLOPE ROOF 52 52 DECK CARPORT 52 52 9.17' LEVEL 1 19.08' LEVEL 2 28.67' LEVEL 3 38.00' T.O.R. MAX. ALLOWED SLOPED ROOF 9.17' LEVEL 1 19.08' LEVEL 2 28.67' LEVEL 3 38.00' T.O.R. MAX. ALLOWED 33.00' T.O.R. MAX. ALLOWED FLAT ROOF 33.00' T.O.R. MAX. ALLOWED FLAT ROOF 123 1231 1 2 238.00 TR38.00 TR32.17 TW32.17 TW44 8 44 8 43 43 43 43 28'-10"9'-11"9'-7"9'-4"23'-10"8'-8"8'-6"8'-10"ENTRY/ STAIRENTRY/ STAIR PANTRY PANTRY STAIR/ LANDING STAIR/ LANDING BONUS BONUS MTL-3MTL-3 STUC WD-1 STUC WD-1 36.33 TR36.33 TR36.33 TRHT. CERT. REQ'D HT. CERT. REQ'D HT. CERT. REQ'DHT. CERT. REQ'D 42 42 42 4242" MINABV. F.F.42" MINABV. F.F.A4.1 1/4"=1'-0" SHEET NUMBER PLOT DATE: SCALE: 9.18.18R E S I D E N C EN E W P O R T B E A C H5 1 5 3 6 t h S T R E E T1 hudgins design group, inc.G U O laguna beach, ca, 92651 t: 949.322.7922 1107 south coast hwy e: info@hudginsdesign.com CDP SUB. #2 09.18.18 hudgins design group, inc, expressly reserves its common law copyright and other property rights in these drawings. These drawings are not to be reproduced, changed, or copied in any form or manner whatsoever nor are they to be assigned to any third party without first obtaining theexpressed written permission of hudgins design group, inc. The drawings and specifications remain the property of hudgins design group, inc. Copies of the drawings and specifications retained by the client may be utilized only for his or her use and for occupying the project for which theywere prepared, and not for the construction of any other project.CDP SUB. #1 08.08.18 SECTION - B KEYNOTES MATERIALS LEGEND STONE FLOORING, PORTUGUESE LIMESTONESTN-1 WD-1 TRANSPARENT GLASSGLS-1 MTL-2 STN-2 TRANSPARENT TEMPERED GLASS, AT GUARDRAILSGLS-2 CON-1 INTEGRALLY COLORED SMOOTH TROWEL STUCCO, WHITESTUC PLANTING AREA - REFER TO LANDSCAPE PLANP/A (N) CONCRETE WALL BREAK METAL, PAINTED - 'KYNAR 500' TO MATCH WINDOWS WD-3 VEGETATION/LANDSCAPING PER LANDSCAPE PLANVEG (N) WALL TRASH STORAGE AREA, SCREENED FROM STREET A/C EQUIPMENT, SCREENED W/ SOUND ATTENUATION PER CITY AREA OF OPEN VOLUME - SEE AREA CALCS SHEET A1.2 OUTDOOR FIRE PIT W/ DRAINAGE, +18" A.F.F. PROPOSED MAILBOX LOCATION ASPHALT ROOF SHINGLES, CLASS A, DARK GRAY COLORASPH WOOD FLOORING / CEILING STONE VENEER, SILVER TRAVERTINE HARDSCAPE / PORCH / PATIO (N) SEAWALL EXTENSION PER 'SW' DRAWINGS PROPERTY LINE1 SETBACK ROOF - MIN. CLASS 'A' FIRE RATED BUILDING FOOTPRINT EDGE OF ROOF/ CEILING (ABV/ BLW/ BYD AS OCCURS) 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 EDGE OF WALL (ABV/ BLW/ BYD AS OCCURS) (E) WATER METER LOCATION (REF CIVIL & SURVEY DWGS) FAU - PROVIDE GAS S. O., POWER, AND VENTING AS REQ'D. BY MFGR. (CMC 904. 1) STRUCTURAL COLUMN / BEAM PER STRUCTURAL FF/ FS/ FG/ EG (ABOVE/ BELOW/ BEYOND AS OCCURS) (E) CURB/ EDGE OF PAVEMENT FIXED DATUM POINT/ BENCHMARK CONTINUOUS RECESSED STRIP DRAIN - SEE CIVIL DWG'S (E) GRADE (N) FINISH GRADE/ FINISH SURFACE GARAGE CENTERLINE OF RIGHT OF WAY WATER HEATER - TANK-LESS (ON DEMAND) WALL -MOUNT +44" MIN., VERIFY SIZE REQ'D. W/. MFGR. (PROVIDE GAS) DOOR/ WINDOW PER SCHEDULE (ABV/ BLW/ BYD AS OCCURS) WOOD DECK (ABV/ BLW/ BYD) O/ SLEEPERS O/ CONC BASE 42 43 EXTERIOR STAIRS/STEPS - REF. CIVIL DRAWINGS 44 (N) GATE - AS SELECTED 45 46 47 48 49 GARAGE DOOR & TRACK (ABV) - INSTALL PER MANUF. SPEC. 50 51 52 PROPOSED MAIN SERVICE PANEL, 400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION) - VERIFY LOCATION W/. SO. CA. EDISON 53 54 55 56 CABINETRY (N) DRIVEWAY PLANTING/SOFTSCAPE AREA - SEE LANDSCAPE PLANS PAVERS - SEE LANDSCAPE PLANS EXISTING / PROPOSED GAS METER LOCATION OUTLINE OF EXISTING STRUCTURE TO BE REMOVED/DEMOLISHED BBQ, PROVIDE GAS AND ELEC. PER OWNER BENCH, +18" A.F.F. (N) DECORATIVE CHIMNEY SHROUD MODEL S11 BY 'AMERICAN CHIMNEY SHROUD.' UL LISTING (MH30042) & WH LISTING (5091753). TERMINATE 2FT MINIMUM ABOVE BUILDING PER CRC R1003.9 ROOF CRICKET, BUILT-UP AS REQUIRED COUNTER, +36" A.F.F. ROOF DRAIN W/ OVERFLOW AND CONCEALED PIPES PER CPC TABLES 11-1 AND 11-2 57 58 ROOF RIDGE/ VALLEY 59 60 ROOF PARAPET COUNTER, +30" A.F.F. STEEL UTILITY DOOR, VERIFY LOUVER REQUIREMENT SKYLIGHT (ABV / BLW / BYD AS OCCURS) ICC-ES ESR 2415 61 RECESSED CURTAIN/SHADE TRACK, MOTORIZED W/ REMOTE 62 63 WOOD SIDING, 7" JAMES HARDIE PLANK, ARTISAN V-GROOVE KHAKI BROWN COLOR CONCRETE FLOORING/DECKING ADJACENT BUILDING PLANTER AREA COUNTER, +42" A.F.F. EXTERIOR SIDING, PER ELEVATIONS (E) UTILITY VAULT/BOX LOCATION (REF CIVIL & SURVEY DWGS) EXTERIOR GUARDRAIL, MIN HEIGHT +42" A.F.F. ROOF EAVE PROJECTION, 30" MAX INTO SETBACKS DRAIN LINE, IN WALL/FROM ABV. REF. CIVIL DWGS. NOT USED (N) STAIRS W/ MAXIMUM RISER HEIGHT SHALL BE 7-3/4" AND A MINIMUM OF 4". MINIMUM TREAD DEPTH SHALL BE 10". PROVIDE ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT CANDLE (CBC 1205.4) 34"-38" HIGH GUARDRAIL/ HANDRAIL @ STAIR FRAMELESS TEMPERED/LAMINATED GLASS GUARDRAIL PER CBC 2407. INSTALL PER MANUF. SPECS, ICCES-ESR-3269 PROVIDE (N) FAU, HEAT PER CRC R303.9 GAS FIREPLACE - 'MONTIGO' - ANSI Z21.50 / CSA 2.22-2014 AND ANSI Z21.97 / CSA 2.41-2014. DIRECT VENT, SEALED COMBUSTION, FIXED TREMPERED GLASS FRONT MODEL R520. CERTIFICATE # 1455422 WD-2 WOOD SIDING, 2-3/4" VERTICAL RESYSTA, DARK GREY COLOR MTL-1 STANDING SEAM ZINC METAL ROOF, CLASS "A", DARK GREY W/ 16" CONTINUOUS PANS. 64 SETBACK AREA ALLOWED FOR MINOR STRUCTURES65 4 SIDED POLYGON USED TO ESTABLISH GRADE 66 FENCE / SITE WALL - 42" MAX. IN FRONT67 ADDITIONAL THIRD FLOOR SETBACK68 (E) FENCE / SITE WALL - 72" MAX. PROTECT IN PLACE. MTL-3 STEEL GUARDRAIL, PAINTED - 'KYNAR 500' TO MATCH WINDOWS MTL-4 METAL DOOR, PAINTED - 'KYNAR 500' SECTION - A 1 1 1 11 1 1 29 30 31 32 33 34 STONE PAVERS Echeveria derenbergii Festuca glauca 'Elijah Blue' Agave 'Blue Glow' Euphoria tirucalli 'Sticks on Fire' Cortaderia selloana 'Pumila' Aloe 'Hercules' BOTANICAL NAME COMMON NAME MATURE WIDTH Painted Lady Elijah Blue Fescue Blue Glow Agave Red Pencil Tree Dwarf Pampas Grass Hercules Aloe <1' 1' - 2' 2' - 3' 3' - 5' 4' - 6' 10' - 15' MATURE HEIGHT <1' <1' 1' - 2' 4' - 8' 4' - 6' 20' - 30' GRAVEL PLANTING SIZE FLATS 1 GALLON 2 GALLON 5 GALLON 5 GALLON 24" BOX A1.1 1/8"=1'-0" SHEET NUMBER PLOT DATE: SCALE: 8.8.18R E S I D E N C EN E W P O R T B E A C H5 1 5 3 6 t h S T R E E Thudgins design group, inc.G U O laguna beach, ca, 92651 t: 949.322.7922 1107 south coast hwy e: info@hudginsdesign.com CDP SUB. #1 08.08.18 hudgins design group, inc, expressly reserves its common law copyright and other property rights in these drawings. These drawings are not to be reproduced, changed, or copied in any form or manner whatsoever nor are they to be assigned to any third party without first obtaining theexpressed written permission of hudgins design group, inc. The drawings and specifications remain the property of hudgins design group, inc. Copies of the drawings and specifications retained by the client may be utilized only for his or her use and for occupying the project for which theywere prepared, and not for the construction of any other project.LANDSCAPE PLAN PROJECT NORTHTRUE NORTH37°35 (* ) (* ) NOTE :PMA Consulting, Inc.Consulting Structural Engineers28161 Casitas Ct., Laguna Niguel, CA 92677Phone: (714) 717-7542E-Mail: P.Petrov@PMA-BG.comREINFORCING THE EXISTINGSEAWALL/BULKHEAD LOCATED AT:515 36th StreetNewport Beach, CA 92663Mr. Jack Guo515 36th StreetNewport Beach, CA 92663SW-2 36