Loading...
HomeMy WebLinkAbout10_Clarizio Residence Coastal Development Permit_PA2018-19003/13/2018 CITY OF NEWPORT BEACH ZONING ADMINISTRATOR STAFF REPORT October 25, 2018 Agenda Item No. 10 SUBJECT: Clarizio Residence (PA2018-190) Coastal Development Permit No. CD2018-081 SITE LOCATION: 7401 Seashore Drive APPLICANT: Chris Clarizio OWNER: Dino and Hope Clarizio PLANNER: David Lee, Assistant Planner 949-644-3225, dlee@newportbeachca.gov LAND USE AND ZONING General Plan: RT (Two-Unit Residential) Zoning District : R-2 (Two-Unit Residential) Coastal Land Use Category: Two-Unit Residential– (30.0-39.9 DU/AC) (RT-E) Coastal Zoning District: Two-Unit Residential (R-2) PROJECT SUMMARY A request for a coastal development permit (CDP) to allow the construction a third-story roof deck to an existing duplex. An addition and remodel to the existing duplex was approved and is currently under construction. The height of the existing dwelling will be increased by approximately 3 feet 7 inches from the existing flat roof to the top of the proposed guardrail. The addition of the third-story roof deck increases the height by more than 10 percent of the existing height of the dwelling and causes the requirement for a coastal development permit. RECOMMENDATION 1)Conduct a public hearing; 2)Find this project exempt from the California Environmental Quality Act (CEQA) pursuant to Section 15301 under Class 1 (Existing Facilities), because it has no potential to have a significant effect on the environment; and 3)Adopt Draft Zoning Administrator Resolution No. _ approving Coastal Development Permit No. CD2018-081 (Attachment No. ZA 1). 1 Clarizio Residence CDP Zoning Administrator, October 25, 2018 Page 2 Tmplt: 03/13/18 DISCUSSION Land Use and Development Standards  The subject property is located in the R-2 Coastal Zoning District, which provides for two-unit residential development and is consistent with the City’s Coastal Land Use Plan, General Plan, and Zoning Code. A Coastal Development Permit is required and the property is not eligible for a waiver for de minimis development because the property is located in the Coastal Commission Appeal Area.  An addition and remodel to the existing duplex was approved and is currently under construction. The addition was determined to be exempt from the requirement of a coastal development permit. The addition of the third-story roof deck and stairwell enclosure increases the height by more than 10 percent of the existing height of the dwelling and causes the requirement for a coastal development permit.  The property currently consists of one legal lot developed with a duplex. The neighborhood is predominantly developed with two - and three-story, single-family residences and duplexes. The design, bulk, and scale of the development is consistent with the existing neighborhood pattern of development and expected future development consistent with applicable development standards. The addition of the third-story roof deck remains compatible with existing and allowed development in the neighborhood.  The property is considered nonconforming due to parking because only two one - car garage spaces are provided, where the Zoning Code and Local Coastal Program requires one space in a garage and one space covered or in a garage per dwelling unit. The Zoning Code and Local Coastal Program allows for additions up to a maximum of 10 percent of the existing floor area of a structure nonconforming due to parking within a 10 year period. No increase of floor area is proposed with the proposed roof deck addition.  The existing duplex conforms to all other applicable development standards, including floor area limit, setbacks, and height, as evidenced by the project plans and illustrated in Table 1 below. The duplex will remain in compliance with all development standards with the addition of the third-story roof deck and enclosed stairwell. Table 1 – Development Standards Development Standard Standard Proposed Setbacks (min.) Front 0 feet 3’-8” Sides 3 feet 3 feet Rear 5 feet 5 feet Allowable Floor Area (max.) 3,794 square feet 2,993 square feet 2 Clarizio Residence CDP Zoning Administrator, October 25, 2018 Page 3 Tmplt: 03/13/18 Allowable 3rd Floor Area (max.) 284 square feet 0 square feet Open Space (min.) 284 square feet 415 square feet Parking (min.) 4 Spaces 3 spaces (non-conforming) Height (max) 24 feet flat roof 29 feet sloped roof 22’-4” flat roof N/A Hazards  The property is located in an area known for the potential of seismic activity and liquefaction. All projects are required to comply with the California Building Code (CBC) and Building Division standards and policies. Geotechnical investigations specifically addressing liquefaction are required to be reviewed and approved prior to the issuance of building permit. Permit issuance is also contingent on the inclusion of design mitigation identified in the investigations. Construction plans are reviewed for compliance with approved investigations and CBC prior to building permit issuance.  The development is set back approximately 570 feet from the mean high water line. Due to the large distance from coastal waters, a Water Quality Management Plan (WQMP) and a Construction Pollution Prevention Plan (CPPP) are not required. Public Access  The project site is located in West Newport between the nearest public road and the sea. Implementation Plan Section 21.30A.040 (Determination of Public Access/Recreation Impacts) requires that the provision of public access bear a reasonable relationship between the requirement and the project’s impact and be proportional to the impact. In this case, the project is the addition of a third-story roof deck to an existing duplex located on a private lot. Therefore, the project does not involve a change in land use, density or intensity that will result in increased demand on public access and recreation opportunities. Furthermore, the project is designed and sited so as not to block or impede existing public access opportunities.  The project site is not located adjacent to a coastal view road, or public viewpoint, as identified in the Coastal Land Use Plan. Furthermore, an investigation of the project site and surrounding area did not identify any other public view opportunities. The project may be located within the viewshed of distant public viewing areas. However, the project is located on an inland lot, and the addition to the existing duplex complies with all applicable Local Coastal Program (LCP) development standards and maintains a building envelope consistent with the existing neighborhood pattern of development. Therefore, the project does not have the potential to degrade the visual quality of the Coastal Zone or result in significant adverse impacts to public views.  The Coastal Land Use Plan identifies Seashore Drive as a means of lateral access to the nearby public beach. Vertical access to the public beach is provided by Summit 3 Clarizio Residence CDP Zoning Administrator, October 25, 2018 Page 4 Tmplt: 03/13/18 Street and Olive Street. The addition of the roof deck does not impact access to the public beach. ENVIRONMENTAL REVIEW This project is exempt from the California Environmental Quality Act (CEQA) pursuant to Section 15301 under Class 1 (Existing Facilities) of the CEQA Guidelines, California Code of Regulations, Title 14, Chapter 3, because it has no potential to have a significant effect on the environment. The Class 1 exemption includes the additions to existing structures. The proposed project is the addition a new roof deck and stair enclosure to an existing duplex located in the R-2 Coastal Zoning District. PUBLIC NOTICE Notice of this public hearing was published in the Daily Pilot, mailed to all owners and residential occupants of property within 300 feet of the boundaries of the site (excluding intervening rights-of-way and waterways), including the applicant, and posted on the subject property at least 10 days before the scheduled hearing, consistent with the provisions of the Municipal Code. Additionally, the item appeared on the agenda for this meeting, which was posted at City Hall and on the City website. APPEAL PERIOD: This action shall become final and effective 14 days following the date the Resolution is adopted unless within such time an appeal or call for review is filed with the Community Development Director in accordance with the provisions of Title 21 (Local Coastal Implementation Plan) of the Newport Beach Municipal Code. Final action taken by the City may be appealed to the Coastal Commission in compliance with Section 21.64.035 of the City’s certified LCP and Title 14 California Code of Regulations, Sections 13111 through 13120, and Section 30603 of the Coastal Act. For additional information on filing an appeal, contact the Planning Division at 949-644-3200. Prepared by: __________________________ David S. Lee, Assistant Planner JM/dl Attachments: ZA 1 Draft Resolution ZA 2 Vicinity Map ZA 3 Project Plans 4 03/13/2018 Attachment No. ZA 1 Draft Resolution 5 RESOLUTION NO. ZA2018-### A RESOLUTION OF THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH APPROVING COASTAL DEVELOPMENT PERMIT NO. CD2018-081 TO ADD A THIRD- STORY ROOF DECK TO AN EXISTING DUPLEX LOCATED AT 7401 SEASHORE DRIVE (PA2018-190) THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH HEREBY FINDS AS FOLLOWS: SECTION 1. STATEMENT OF FACTS. 1. An application was filed by Chris Clarizio, with respect to property located at 7401 Seashore Drive, and legally described as Lot 8 of Block N, requesting approval of a Coastal Development Permit. 2. The applicant proposes the construction a third-story roof deck to an existing duplex. An addition and remodel to the existing duplex was approved and is currently under construction. The height of the existing dwelling will be increased by approximately 3 feet 7 inches from the existing flat roof to the top of the proposed guardrail. The addition of the third-story roof deck increases the height by more than 10 percent of the existing height of the dwelling and causes the requirement for a coastal development permit. 3. The subject property is located within the Two-Unit Residential (R-2) Zoning District and the General Plan Land Use Element category is Two-Unit Residential (RT). 4. The subject property is located within the coastal zone. The Coastal Land Use Plan category is Two Unit Residential – (20.0 - 29.9 DU/AC) (RT-E) and the Coastal Zoning District is Single-Unit Residential (R-2). 5. A public hearing was held on October 25, 2018, in the Corona del Mar Conference Room (Bay E-1st Floor) at 100 Civic Center Drive, Newport Beach. A notice of time, place, and purpose of the hearing was given in accordance with the Newport Beach Municipal Code. Evidence, both written and oral, was presented to, and considered by, the Zoning Administrator at this hearing. SECTION 2. CALIFORNIA ENVIRONMENTAL QUALITY ACT DETERMINATION. 1. This project is categorically exempt pursuant to Title 14 of the California Code of Regulations (Section 15301, Article 19 of Chapter 3, Guidelines for Implementation of the California Environmental Quality Act (CEQA) under Existing Facilities), because it has no potential to have a significant effect on the environment. 2. Class 1 includes additions to existing structures. The proposed project is the addition of a new roof deck to an existing duplex located in the R-2 Coastal Zoning District. 6 Zoning Administrator Resolution No. ZA2018-019 Page 2 of 6 01-03-17 SECTION 3. REQUIRED FINDINGS. In accordance with Section 21.52.015 (Findings and Decision) of the Newport Beach Municipal Code, the following findings and facts in support of such findings are set forth: Finding: A. Conforms to all applicable sections of the certified Local Coastal Program. Facts in Support of Finding: 1. An addition and remodel to the existing duplex was approved and is currently under construction. The approved 241-square-foot addition creates a total floor area (including garage spaces) of 2,993 square feet. The applicant requests to add a new 333-square- foot open roof deck. The height of the duplex will increase from approximately 18 feet 9 inches to 22 feet 4 inches, which is an increase of approximately 19 percent. 2. The property is considered nonconforming due to parking because only two one-car garage spaces are provided, where the Zoning Code and Local Coastal Program requires one space in a garage and one space covered or in a garage per dwelling unit. The Zoning Code and Local Coastal Program allows for additions up to a maximum of 10 percent of the existing floor area of a structure nonconforming due to parking within a 10 year period. No increase of floor area is proposed with the proposed roof deck addition. 3. The proposed development complies with all other applicable residential development standards including, but not limited to, floor area limitation, setbacks, and height. a. The maximum floor area limitation is 3,794 square feet. The previously approved addition that is currently under construction has a proposed floor area of 2,993 square feet. No additional floor area is proposed as part of the roof deck addition . b. The proposed development complies with the required setbacks, which are 5 feet along the property line abutting West Ocean Front Alley, and 3 feet along each side property line. There is no required setback abutting Seashore Drive. c. The highest guardrail/parapet is 22 feet 4 inches from established grade. The proposed development complies with all height requirements. 4. The neighborhood is predominantly developed with two- and three-story single-family residences and duplexes. The proposed design, bulk, and scale of the development is consistent with the existing neighborhood pattern of development and expected future development. 5. The development is set back approximately 570 feet from the mean high water line. Due to the large distance from coastal waters, a Water Quality Management Plan (WQMP) and a Construction Pollution Prevention Plan (CPPP) are not required. 6. The property is located in an area known for the potential of seismic activity and liquefaction. All projects are required to comply with the California Building Code (CBC) 7 Zoning Administrator Resolution No. ZA2018-019 Page 3 of 6 01-03-17 and Building Division standards and policies. Geotechnical investigations specifically addressing liquefaction are required to be reviewed and approved prior to the issuance of building permits. Permit issuance is also contingent on the inclusion of design mitigation identified in the investigations. Construction plans are reviewed for compliance with approved investigations and CBC prior to building permit issuance. 7. Landscaping is not proposed as a part of this project. Finding: B. Conforms with the public access and public recreation policies of Chapter 3 of the Coastal Act if the project is located between the nearest public road and the sea or shoreline of any body of water located within the coastal zone . Fact in Support of Finding: 1. The project site is located between the nearest public road and the sea or shoreline; the project will not affect the public’s ability to gain access to, use, and/or view the coast and nearby recreational facilities. 2. The project site is located in West Newport between the nearest public road and the sea. Implementation Plan Section 21.30A.040 (Determination of Public Access/Recreation Impacts) requires that the provision of public access bear a reasonable relationship between the requirement and the project’s impact and be proportional to the impact. In this case, the project is the addition of a third-story roof deck to an existing duplex located on a private lot. Therefore, the project does not involve a change in land use, density or intensity that will result in increased demand on public access and recreation opportunities. Furthermore, the project is designed and sited so as not to block or impede existing public access opportunities. 3. The project site is not located adjacent to a coastal view road, or public viewpoint, as identified in the Coastal Land Use Plan. Furthermore, an investigation of the project site and surrounding area did not identify any other public view opportunities. The project may be located within the viewshed of distant public viewing areas. However, the project is located on an inland lot, and the addition to the existing duplex complies with all applicable Local Coastal Program (LCP) development standards and maintains a building envelope consistent with the existing neighborhood pattern of development. Therefore, the project does not have the potential to degrade the visual quality of the Coastal Zone or result in significant adverse impacts to public views. 4. The Coastal Land Use Plan identifies Seashore Drive as a means of lateral access to the nearby public beach. Vertical access to the public beach is provided by Summit Street and Olive Street. The addition of the roof deck does not impact access to the public beach. 8 Zoning Administrator Resolution No. ZA2018-019 Page 4 of 6 01-03-17 SECTION 4. DECISION. NOW, THEREFORE, BE IT RESOLVED: 1. The Zoning Administrator of the City of Newport Beach hereby approves Coastal Development Permit No. CD2018-081, subject to the conditions set forth in Exhibit “A,” which is attached hereto and incorporated by reference. 2. This action shall become final and effective 14 days following the date this Resolution was adopted unless within such time an appeal or call for review is filed with the Community Development Director in accordance with the provisions of Title 21 Local Coastal Implementation Plan, of the Newport Beach Municipal Code. Final action taken by the City may be appealed to the Coastal Commission in compliance with Section 21.64.035 of the City’s certified LCP and Title 14 California Code of Regulations, Sections 13111 through 13120, and Section 30603 of the Coastal Act. PASSED, APPROVED, AND ADOPTED THIS 25TH DAY OF OCTOBER, 2018. _____________________________________ Patrick J. Alford, Zoning Administrator 9 Zoning Administrator Resolution No. ZA2018-019 Page 5 of 6 01-03-17 EXHIBIT “A” CONDITIONS OF APPROVAL 1. The development shall be in substantial conformance with the approved site plan, floor plans, and building elevations stamped and dated with the date of this approval (except as modified by applicable conditions of approval). 2. Revisions to the approved plans may require an amendment to this Coastal Development Permit or the processing of a new Coastal Development Permit. 3. Coastal Development Permit No. CD2018-081 shall expire unless exercised within 24 months from the date of approval as specified in Section 21.54.060 (Time Limits and Extensions) of the Newport Beach Municipal Code, unless an extension is otherwise granted. 4. The project is subject to all applicable City ordinances, policies, and standards, unless specifically waived or modified by the conditions of approval. 5. The applicant shall comply with all federal, state, and local laws. Material violation of any of those laws in connection with the use may be cause for revocation of this Coastal Development Permit. 6. This Coastal Development Permit may be modified or revoked by the Zoning Administrator if determined that the proposed uses or conditions under which it is being operated or maintained is detrimental to the public health, welfare or materially injurious to property or improvements in the vicinity or if the property is operated or maintained so as to constitute a public nuisance. 7. Prior to issuance of the building permits, a copy of the Resolution, including conditions of approval Exhibit “A” shall be incorporated into the Building Division and field sets of plans. 8. Prior to issuance of building permits, the applicant shall submit to the Planning Division an additional copy of the approved architectural plans for inclusion in the Coastal Development file. The plans shall be identical to those approved by all City departments for building permit issuance. The approved copy shall include architectural sheets only and shall be reduced in size to 11 inches by 17 inches. The plans shall accurately depict the elements approved by this Coastal Development Permit. 9. Prior to the issuance of building permits, the applicant shall submit a final construction erosion control plan. The plan shall be subject to the review and approval by the Building Division. 10. Prior to the issuance of building permit, the applicant shall pay any unpaid administrative costs associated with the processing of this application to the Planning Division. 10 Zoning Administrator Resolution No. ZA2018-019 Page 6 of 6 01-03-17 11. Should the property be sold or otherwise come under different ownership, any future owners or assignees shall be notified of the conditions of this approval by either the current business owner, property owner, or the leasing agent. 12. This approval shall expire and become void unless exercised within 24 months from the actual date of review authority approval, except where an extension of time is approved in compliance with the provisions of Title 21 Planning and Zoning of the Newport Beach Municipal Code. 13. To the fullest extent permitted by law, applicant shall indemnify, defend and hold harmless City, its City Council, its boards and commissions, officials, officers, employees, and agents from and against any and all claims, demands, obligations, damages, actions, causes of action, suits, losses, judgments, fines, penalties, liabilities, costs and expenses (including without limitation, attorney’s fees, disbursements and court costs) of every kind and nature whatsoever which may arise from or in any manner relate (directly or indirectly) to City’s approval of Clarizio Residence Coastal Development Permit including, but not limited to, Coastal Development Permit No. CD2018-081 (PA2018-190). This indemnification shall include, but not be limited to, damages awarded against the City, if any, costs of suit, attorneys' fees, and other expenses incurred in connection with such claim, action, causes of action, suit or proceeding whether incurred by applicant, City, and/or the parties initiating or bringing such proceeding. The applicant shall indemnify the City for all of City's costs, attorneys' fees, and damages which City incurs in enforcing the indemnification provisions set forth in this condition. The applicant shall pay to the City upon demand any amount owed to the City pursuant to the indemnification requirements prescribed in this condition. 11 03/13/2018 Attachment No. ZA 2 Vicinity Map 12 03/13/2018 VICINITY MAP Coastal Development Permit No. CD2018-081 PA2018-190 7401 Seashore Drive Subject Property 13 03/13/2018 Attachment No. ZA 3 Project Plans 14 CLIENT: LICENCE STAMP: PROJECT TEAM: CONTACT: E-MAIL: E-MAIL: PRINCIPAL: PROJECT DIRECTOR: PROJECT DESIGNER: HOMER OATMAN hoatman@oatmanarchitects.com cadams@oatmanarchitects.com HOMER OATMAN CORY ADAMS BEHTASH AZAR THESE DRAWINGS ARE THE PROPERTY OF OATMAN ARCHITECTS AND SHALL NOT BE MODIFIED OR USED ON ANY OTHER PROJECT OR SITE WITHOUT WRITTEN PERMISSION. IT IS THE OWNER'S AND IT'S GENERAL CONTRACTOR'S RESPONSIBILITY, PRIOR TO OR DURING CONSTRUCTION, TO NOTIFY THE ARCHITECT IN WRITING OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND/ OR GENERAL NOTES OF WHICH A CONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND MEANS & METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE ARCHITECT PRIOR TO THE OWNER OR OWNER'S CONTRACTOR PROCEEDING WITH THE WORK. THE OWNER WILL BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT FOLLOWED. NOTE: THE ORIGINAL SIZE OF THIS DRAWING SHEET IS: 36"X48" Project Number: SUBMITTAL: REVISION: DATE DESCRIPTION 8/9/2018 3:24:43 PM T1.0 COVER SHEETCLARIZIO REMODEL7401 SEASHORE, NEWPORT BEACH, CALOT 8, BLOCK N, SEASHORE COLONY TRACTPLAN CHECK # 0696-2018CDP SUBMITTALCHRIS CLARIZIO 2017005 03/23/18 BLDG. DEPT. SUBMITTAL 1 06/08/18 BLDG. DEPT. SUBMITTAL 2 06/28/18 BLDG. DEPT. SUBMITTAL 3 08/10/18 CDP SUBMITTAL NO. DATE DESCRIPTION 15 CLIENT: LICENCE STAMP: PROJECT TEAM: CONTACT: E-MAIL: E-MAIL: PRINCIPAL: PROJECT DIRECTOR: PROJECT DESIGNER: HOMER OATMAN hoatman@oatmanarchitects.com cadams@oatmanarchitects.com HOMER OATMAN CORY ADAMS BEHTASH AZAR THESE DRAWINGS ARE THE PROPERTY OF OATMAN ARCHITECTS AND SHALL NOT BE MODIFIED OR USED ON ANY OTHER PROJECT OR SITE WITHOUT WRITTEN PERMISSION. IT IS THE OWNER'S AND IT'S GENERAL CONTRACTOR'S RESPONSIBILITY, PRIOR TO OR DURING CONSTRUCTION, TO NOTIFY THE ARCHITECT IN WRITING OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND/ OR GENERAL NOTES OF WHICH A CONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND MEANS & METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE ARCHITECT PRIOR TO THE OWNER OR OWNER'S CONTRACTOR PROCEEDING WITH THE WORK. THE OWNER WILL BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT FOLLOWED. NOTE: THE ORIGINAL SIZE OF THIS DRAWING SHEET IS: 36"X48" Project Number: SUBMITTAL: REVISION: DATE DESCRIPTION 8/9/2018 3:24:51 PM IN1.0 INDEX SHEETCLARIZIO REMODEL7401 SEASHORE, NEWPORT BEACH, CALOT 8, BLOCK N, SEASHORE COLONY TRACTPLAN CHECK # 0696-2018CDP SUBMITTALCHRIS CLARIZIO 2017005 03/23/18 BLDG. DEPT. SUBMITTAL 1 06/08/18 BLDG. DEPT. SUBMITTAL 2 06/28/18 BLDG. DEPT. SUBMITTAL 3 08/10/18 CDP SUBMITTAL REVISION LIST PROJECT TEAM CONSTRUCTION VALUATION THE FOLLOWING PROJECT CONSISTS OF A REMODELED 2-STORY ABOVE GRADE DUPLEX WITH 2 ATTACHED 1-CAR GARAGES AT THE FIRST FLOOR LEVEL TOTAL BEDROOMS: (8) TOTAL BATHS: (5) FULL BATHS *THE EXISTING STRUCURE IS A DUPLEX AND THE PROJECT WILL REMAIN A DUPLEX. NO REHABILITATED LANDSCAPE IS PROPOSED. 1. SEPARATE DRAWING SUBMITTAL(S) AND PERMIT(S) IS/ARE REQUIRED FOR SWIMMING POOL AND SPA, POOL AND SPA MECHANICAL EQUIPMENT, ANY SITE RETAINING WALLS OVER 4 FEET HIGH FROM THE BOTTOM OF THE FOUNDATION TO TOP OF WALL, ANY BLOCK WALLS OVER 3.5 FEET, MASONRY OR CONCRETE FENCES OVER 3.5 FEET HIGH, DETACHED PATIO COVERS, TRELLISES, ACCESSORY BUILDING(S) . . .ETC. 2. SEPARATE DRAWING SUBMITTAL(S) AND PERMIT(S) IS/ARE REQUIRED FOR THE N.F.P.A. 13-D AUTOMATIC FIRE SPRINKLER SYSTEM. THE SYSTEM SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH THE 2013 N.F.P.A. 13-D AND AMENDMENTS AS ADOPTED BY THE LOCAL JURISDICTION. SPRINKLER IS REQUIRED AT PLANS SHALL BE SUBMITTED AND APPROVED BY PRIOR TO ISSUING A BUILDING PERMIT OR SHALL BE OBTAINED PRIOR TO CALLING FOR ROOF SHEATHING INSPECTION. THE SYSTEM SHALL BE OPERATIONAL PRIOR TO THE ISSUANCE OF A CERTIFICATE OF USE AND OCCUPANCY FOR ALL ONSITE STRUCTURES. 3. ALL DEFERRED SUBMITTALS ARE TO BE REVIEWED BY THE PROJECT ARCHITECT OR ENGINEER OF RECORD, AND CERTIFIED PRIOR TO SUBMITTAL FOR PLAN REVIEW. THE FOLLOWING DEFERRED SUBMITTALS ARE REQUIRED: A. FIRE SPRINKLER SYSTEM B. HVAC EQUIPMENT SOUND ATTENUATION DEFERRED SUBMITTALS TRACT SEASHORE COLONY LOT AREA: 2,560 S.F. MAX. ALLOWABLE S.F.: 3,794.4 S.F. PARCEL (APN):045-021-03 LOT:8 BLOCK:N MINIMUM BUILDING SETBACKS: FRONT YARD:0'-0" FROM ANY FRONT PROPERTY LINE REAR YARD:5'-0" FROM ANY REAR PROPERTY LINE SIDE YARD:3'-0" FROM ANY SIDE PROPERTY LINE MAXIMUM BUILDING HEIGHT: SLOPED ROOF: 0'-0" ABOVE NATURAL GRADE PER EXHIBIT 'A' MAXIMUM BUILDING AREA: BUILDABLE AREA = 2,560 SF (LA) - 662.8 SF (SB) = 1897.2 SF MAXIMUM FLOOR AREA = 1897.2 X 2 = 3,794.4 SF 2016 CALIFORNIA RESIDENTIAL CODE 2016 CALIFORNIA BUILDING CODE 2016 CALIFORNIA MECHANICAL CODE 2016 CALIFORNIA PLUMBING CODE 2016 CALIFORNIA ELECTRICAL CODE 2016 CALIFORNIA FIRE CODE 2016 CALIFORNIA ENERGY CODE 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE 2016 TITLE-24 BUILDING ENERGY EFFICIENCY STANDARDS THE CITY OF NEWPORT BEACH, CA MUNICIPAL AND ZONING CODE THIS PROJECT SHALL COMPLY WITH ALL OTHER REGULATIONS AND ORDINANCES ADOPTED BY THE LOCAL GOVERNING AGENCY OF THE CITY OF NEWPORT BEACH CALIFORNIA GREEN GENERAL NOTES: REFER TO GENERAL NOTE AND MEP SHEETS FOR APPLICABLE CALIFORNIA GREEN BUILDING STANDARDS CODE REQUIREMENTS AS IT PERTAINS TO LOW-RISE RESIDENTIAL BUILDINGS. USE:EXISTING RESIDENTIAL DUPLEX OCCUPANCY TYPE:R-3 /U (LIGHT STORAGE & PRIVATE GARAGE) TYPE OF CONSTRUCTION:V-B (N.F.P.A. 13D SPRINKLER SYESTEM PROVIDED) ISSUANCE OF A BUILDING PERMIT BY THE CITY OF NEWPORT BEACH DOES NOT RELIEVE APPLICANTS OF THE LEGAL REQUIREMENTS TO OBSERVE COVENANTS, CONDITIONS AND RESTRICTIONS WHICH MAY BE RECORDED AGAINST THE PROPERTY OR TO OBTAIN PLANS. YOU SHOULD CONTACT YOUR COMMUNITY ASSOCIATIONS PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION AUTHORIZED BY THIS PERMIT. PRIOR TO PERFORMING ANY WORK IN THE CITY RIGHT-OF-WAY AN ENCROACHMENT PERMIT MUST BE OBTAINED FROM THE PUBLIC WORKS DEPARTMENT. NONCONFORMING DUE TO PARKING - ADDITIONS UP TO A MAXIMUM OF TEN PERCENT OF THE EXI STING FLOOR AREA OF THE STRUCTURE WITHIN A TEN YEAR PERIOD ARE PERMITTED. FENCES, HEDGES, WALLS, RETAINING WALLS, GUARDRAILS AND HANDRAILS OR ANY COMBINATION THEREOF SHALL NOT EXCEED 42 INCHES FROM EXISTING GRADE PRIOR TO THE CONSTRUCTION WITHIN THE REQUIRED FRONT SETBACK AREA(S). CODES & REQUIREMENTS ABBREVIATIONS LEGAL DESCRIPTION PROJECT SCOPE CLIENT: CHRIS CLARIZIO 1412 ORLANDO DRIVE ARCHADIA, CA 91006 949-392-3030 CHRIS.CLARIZIO@GMAIL.COM ARCHITECT: OATMAN ARCHITECTS, INC. 412 31ST STREET NEWPORT BEACH, CA 92663 949.675.1755 OFFICE 949.657.1758 FAX CONTACT: HOMER OATMAN, AIA LANDSCAPE ARCHITECT: - - - - - INTERIOR DESIGNER: - - - - - - STRUCTURAL ENGINEER: BURKE STRUCTURAL ENGINEERS, PC 151 KALMUS DRIVE, BLDG, E - 140 COSTA MESA, CA 92626 (657) 289-0460 OFFICE CONTACT: TOMAS BURKE MECHANICAL/PLUMBING ENGINEER/ELECTRICAL ENGINEER: - - - - - - CIVIL ENGINEER: TOAL ENGINEERING, INC. 139 AVENIDA NAVARRO SAN CLEMENTE, CA 92672 949.492.8586 OFFICE CONTACT: CALEB RIOS - GEO TECHINCAL ENGINEER: - - - - - - SITE INFORMATION VICINITY MAP SHEET INDEX CONSTRUCTION NOTES HEIGHT OF CONSTRUCTION DISTANCE FROM CONSTRUCTION TO LOT LINE TYPE OF PEDESTRIAN PROTECTION REQUIRED LESS THAN 5'-0" 5'-0" OR MORE LESS THAN 5'-0" 5'-0" OR MORE, BUT NOTE MORE THAN 1/4 THE HEIGHT OF CONSTRUCTION 5'-0" OR MORE, BUT BETWEEN 1/4 AND 1/2 THE HEIGHT OF CONSTRUCTION 5'-0" OR MORE, BUT EXCEEDING 1/2 THE HEIGHT OF CONSTRUCTION CONSTRUCTION RAILINGS NONE NONE 8'-0" OR LESS MORE THAN 8'-0" BARRIER/COVERED WALKWAY BARRIER/COVERED WALKWAY BARRIER GROSS FLOOR AREA GENERAL T1.0 COVER SHEET IN1.0 INDEX SHEET GN1.0 GENERAL NOTES GN2.0 GENERAL NOTES GN3.0 GENERAL NOTES GN4.0 CITY OF NB REQUIRED FORMS GN5.0 TITLE 24 ARCHITECTURAL A0.1 AS-BUILT SITE PLAN A0.2 AS BUILT PLANS A0.3 AS-BUILT ELEVATIONS A0.4 SITE DEMO PLAN A0.5 DEMO PLAN A0.6 DEMO ELEVATIONS A1.0 ARCHITECTURAL SITE PLAN A3.0 FLOOR PLANS A3.4 FLOOR AREA EXHIBIT A4.0 ROOF PLAN A5.0 EXTERIOR ELEVATIONS A6.0 BUILDING SECTIONS A7.0 REFLECTED CEILING PLANS ARCHITECTURAL DETAILS D1.0 DETAILS D2.0 DOOR & WINDOW DETAILS D3.0 STAIR & RAILING DETAILS UR. URINAL VAN. VANITY VLT. VAULT VERT VERTICAL VEST. VESTIBULE V.S. VEGI SINK W. WEST W/ WITH W.C. WATER CLOSET WD. WOOD W.H. WATER HEATER W/O WITHOUT WP. WATERPROOF WSCT. WAINSCOT WT. WEIGHT WDW. WINDOW STL. STEEL STOR. STORAGE STRL. STRUCTURAL STRUCT' L STRUCTURAL STRUCT STRUCTURE S.S. SERVICE SINK SUSP. SUSPENDED SUB-FL. SUB-FLOOR SW SOLID WOOD SYM. SYMMETRICAL S4S SURFACED 4 SIDES T.B. TOWEL BAR T.B.D TO BE DETERMINED T.C. TOP OF CURB TEL. TELEPHONE TER. TERRAZZO TEMP. TEMPERED T&G TONGUE AND GROOVE THK. THICK T.O.C. TOP OF CURB T.O.D. TOP OF DECKING T.O.P. TOP OF PLATE T.O.PAR . TOP OF PARAPET T.O.S. TOP OF SLAB T.O.PAV . TOP OF PAVEMENT T.P. TOILET PAPER DISPENSER TRANS. TRANSOM TRD. TREAD T.V. TELEVISION T.W. TOP OF WALL TYP. TYPICAL UNF. UNFINISHED U.O.N. UNLESS OTHERWISE NOTED REFR. REFRIGERATOR REV REVERSE REINF REINFORCE, REINFORCED RGTR. REGISTER R.H.B. RECESSED HOSE BIBB REQ. REQUIRED. REQUIREMENTS RESIL. RESILIENT RM. ROOM R.O. ROUGH OPENING R.OS. REVERSE OSMOSIS RWD. REDWOOD R.W.L. RAIN WATER LEADER S. SOUTH S.C. SOLID CORE S.C.D. SEAT COVER DISPENSER SCHED. SCHEDULE S.D. SOAP DISPENSER SECT. SECTION S.F. SQUARE FEET S.H. SINGLE HUNG SHR. SHOWER SHT. SHEET SHTG. SHEATHING SIM. SIMILAR SKYLT. SKYLIGHT SLPG. SLOPING SLDR. SLIDER/ SLIDING S.N.D. SANITARY NAPKIN DISPENSER S.N.R. SANITARY NAPKIN RECEPTACLE SP. SPACE SPEC. SPECIFICATIONS SQ. SQUARE S.ST. STAINLESS STEEL STA. STATION STD. STANDARD O.D. OUTSIDE DIAMETER (DIM.) OFF. OFFICE O.H.C. OVERHEAD CABINET OPNG. OPENING OPP. OPPOSITE PAN. PANTRY P.D. POCKET DOOR PRCST. PRECAST PL. PLATE P.LAM. PLASTIC LAMINATE PLAS. PLASTER PNL. PANEL PTD. PAINTED PLUMB. PLUMBING PLYWD. PLYWOOD PL PROPERTY LINE PR. PAIR P.T. PRESSURE TREATED PREFAB PREFABRICATED P.T.D. PAPER TOWEL DISPENSER P.T.D/R COMBINATRION PAPER TOWEL DISPENSER & RECEPTACLE PTN. PARTITION P.T.R. PAPER TOWEL RECEPTACLE Q.T. QUARRY TILE R. RISER RAD. RADIUS R.A.G. RETURN AIR GRILLE R RADIUS R.C.W. RECESSED COLD WATER R.D. ROOF DRAIN REF. REFERENCE JT. JOINT LAM. LAMINATE LAV. LAVATORY LIN. LINEN LKR. LOCKER LT. LIGHT LVD. LOUVERED MAINT. MAINTENANCE MAX. MAXIMUM M.B. MACHINE BOLT M.C. MEDICINE CABINET MDF MEDIUM DENSITY FIBER BD. MECH. MECHANICAL MEMB. MEMBRANE MET. METAL MFGR. MANUFACTURER MH. MANHOLE MIN. MINIMUM MIR. MIRROR MISC. MISCELLANEOUS M.O. MASONRY OPENING MTD. MOUNTED MTL METAL MUL. MULLION N. NORTH N.I.C. NOT IN CONTRACT NO. OR # NUMBER NOM. NOMINAL N.T.S. NOT TO SCALE O/ OVER O.A. OVERALL OBS. OBSCURE O.C. ON CENTER F.S. FULL SIZE FT. FOOT OR FEET FTG. FOOTING FURR. FURRING FUT. FUTURE GA. GAUGE GALV. GALVANIZED G.B. GRAB BAR GL. GLASS GND. GROUND G.P.F. GALLONS PER FLUSH G.P.M. GALLONS PER MINUTES GR. GRADE GYP. GYPSUM GYP. BD. GYPSUM BOARD G.B. GYPSUM BOARD H.B. HOSE BIBB H.C. HOLLOW CORE HDWD. HARDWOOD HDWE. HARDWARE HDR. HEADER H.M. HOLLOW METAL HORIZ. HORIZONTAL HR. HOUR HT. HEIGHT H.V.A.C HEATING VENTILATING AIR CONDITIONING HORZ HORIZONTAL I.D. INTERIOR DESIGNER I.DIA. INSIDE DIAMETER INSUL. INSULATION INT. INTERIOR JAL. JALOUSIE JAN. JANITOR ELEC. ELECTRICAL ELEV. ELEVATOR EMER. EMERGENCY ENCL. ENCLOSED E.P. ELECTRICAL PANELBOARD EQ. EQUAL EQPT. EQUIPMENT E.W.C. ELECTRIC WATER COOLER EXST. EXISTING EXP. EXPANSION EXPO. EXPOSED EXT. EXTERIOR F.A. FIRE ALARM F.A.U FORCED AIR UNIT F.B. FLAT BAR F.D. FLOOR DRAIN FDN. FOUNDATION F.E. FIRE EXTINGUISHER F.E.C. FIRE EXTINGUISHER CABINET F.F. FINISH FLOOR F.G. FINISH GRADE OR FIXED GLASS F.GAS FUEL GAS F.H.C. FIRE HOSE CABINET FIN. FINISH FIX. FIXED FL. FLOOR FLASH. FLASHING FLUOR. FLUORESCENT F.O.C. FACE OF CONCRETE F.O.F. FACE OF FINISH F.O.M. FACE OF MULLION F.O.S. FACE OF STUDS F.P. FIREPLACE FPRF. FIREPROOF FR. FRENCH FRAM'G FRAMING C.B. CATCH BASIN CEM. CEMENT CER. CERAMIC C.I. CAST IRON C.G. CORNER GUARD CLG. CEILING CLKG. CAULKING COL. COLUMN CONC. CONCRETE CONN. CONNECTION CONSTR . CONSTRUCTION CONT. CONTINUOUS C.O.F. CORNER OF FINISH CORR. CORRIDOR CSMT. CASEMENT CNTR. CENTER CTSK. COUNTERSUNK DBL. DOUBLE DEPT. DEPARTMENT D.F. DRINKING FOUNTAIN DET. DETAIL. DIA. DIAMETER DIM. DIMENSION DN. DOWN D.O. DOOR OPENING DR. DOOR DS. DOWNSPOUT D.S.P. DRY STANDPIPE D.V. DRYER VENT DW DISHWASHER DWG'S DRAWINGS DWR. DRAWER E. EAST EA. EACH E.D.F DRINK FOUNTAIN E.J. EXPANSION JOINT EL. ELEVATION & AND < ANGLE @ AT ₵ CENTERLINE Ø DIAMETER OR ROUND # POUND OR NUMBER (E) EXISTING A.B. ANCHOR BOLT ABV. ABOVE A.C. AIR CONDITIONER ACOUS. ACOUSTICAL A.D. AREA DRAIN ADJ. ADJUSTABLE A.F.F. ABOVE FINISH FLOOR AGGR. AGGREGATE AL. ALUMINUM ALUM. ALUMINUM APPROX . APPROXIMATE ARCH. ARCHITECT ARCH'L. ARCHITECTURAL ASPH. ASPHALT A.V. AUDIO/ VIDEO AWNG. AWNING BD. BOARD BDRM. BEDROOM B.I. BUILT-IN BITUM. BITUMINOUS BLDG. BUILDING BLK. BLOCK BLKG. BLOCKING BLT. BOLT BM. BEAM B.O.B. BOTTOM OF BEAM BOT. BOTTOM B.S. BAR SINK CAB. CABINET ADDITION AREA T.O. SLAB 1ST FL. FIRST FLOOR CARPORT ADDITION 224 SF 224 SF T.O. SHTG 2ND FL. SECOND FLOOR BEDROOM ADDITION 129 SF SECOND FLOOR LIVING ROOM ADD.112 SF SECOND FLOOR DECK ADDITION 191 SF 432 SF T.O. SHTG 3RD FL. ROOF DECK ADDITION 333 SF 333 SF GRAND TOTAL 988 SF REMODEL AREA T.O. SLAB 1ST FL. FIRST FLOOR KITCHEN REMODEL 89 SF FIRST FLOOR REMODELED BEDROOM 160 SF FIRST FLOOR GARAGE DEMO 167 SF DRYWALL DEMO FOR SHEAR 17 SF DRYWALL DEMO FOR SHEAR 39 SF FIRST FLOOR CEILING REMODEL 448 SF FIRST FLOOR CEILING REMODEL 137 SF 1,057 SF T.O. SHTG 2ND FL. SECOND FLOOR REMODELED 841 SF 841 SF GRAND TOTAL 1,898 SF TOTAL = 2,752 SF (EXISTING) + 241 SF (ADDITION) = 2,993 SF *ONLY 241 SF OF THE ADDITION AREA IS CONDITIONED SPACE AND EQUIALS 8.75% OF THE EXISTING BUILDING. SEE SHEET A3.4 FOR ADDITIONAL INFORMATION AND EXHIBITS. OPEN VOLUME AREA: REQUIRED = 1897.2 SF X 15% = 284.58 SF PROVODED = 224 SF (CARPORT) + 191 (DECK) = 415 SF EXISTING S.F. LIVING 2,200 EXISTING S.F. GARAGE 552 TOTAL EXISTING S.F.= 2752 EXISTING AREAS CIVIL C-1 TITLE SHEET C-2 PRECISE GRADING PLAN C-3 SECTIONS AND DETAILS C-4 EROSION CONTROL PLAN C-5 TOPOGRAPHIC SURVEY STRUCTURAL SN1 GENERAL STRUCTURAL NOTES, LEGEND AND ABBREVIATIONS SN2 SPECIAL INSPECTIONS NOTES SN3 SPECIAL INSPECTIONS NOTES ST1 TYPICAL CONCRETE DETAILS ST2 TYPICAL WOOD DETAILS ST3 TYPICAL WOOD DETAILS AND POST IN WALL DETAILS ST4 DRAG DETAILS ST5 TYPICAL HOLDOWN DETAILS ST6 TYPICAL HOLDOWN DETAILS ST7 STRONG WALL WOOD SHEAR WALL C-L-WSW16 ST8 STEEL MOMENT FRAME CONNECTION S1.0 FOUNDATION PLAN S2.0 FLOOR FRAMING PLAN S2.1 ROOF/DECK FRAMING PLAN A 06/08/18 1ST PLAN CHECK CORRECTIONS. B 06/28/18 2ND PLAN CHECK CORRECTIONS. C 08/03/18 ROOF DECK RAILING AND STAIR NO. DATE DESCRIPTION A 06/08/18 PLAN CHECK CORRECTIONS B 06/28/18 PLAN CHECK CORRECTIONS 16 BENCHMARK NOTE: OCSBM 1L-99-91 ELEV=24.742 NAVD88 DATUM, 2005 ADJ. BOUNDARY NOTE: SCALE: 1/8"=1' 1 3 9 A v e n i d a N a v a r r o S a n C l e m e n t e , C A 9 2 6 7 2 9 4 9 .4 9 2 .8 5 8 6 w w w .t o a l e n g i n e e r i n g .c o m C I V I L E N G I N E E R I N G L A N D S U R V E Y I N G S T OR MWA T E R QUA L I T Y EASEMENT NOTES 17 N 36°54'04" E86.00'N 36°54'04" E84.90'N 5 5°1 2'3 8" W 3 0.0 2'N 53°05'56" W30.00'7.50'7.50'LOT 7OLIVE STREETSEASHORE DRIVEA L L E Y TR1TR101Edison manholeTR4Sewer manholeSewer COWater valveFire hydrantW a te r v a lv e TR3Sewer COWater meterElectric boxG a s m e te rCLIENT: LICENCE STAMP: PROJECT TEAM: CONTACT: E-MAIL: E-MAIL: PRINCIPAL: PROJECT DIRECTOR: PROJECT DESIGNER: HOMER OATMAN hoatman@oatmanarchitects.com cadams@oatmanarchitects.com HOMER OATMAN CORY ADAMS BEHTASH AZAR THESE DRAWINGS ARE THE PROPERTY OF OATMAN ARCHITECTS AND SHALL NOT BE MODIFIED OR USED ON ANY OTHER PROJECT OR SITE WITHOUT WRITTEN PERMISSION. IT IS THE OWNER'S AND IT'S GENERAL CONTRACTOR'S RESPONSIBILITY, PRIOR TO OR DURING CONSTRUCTION, TO NOTIFY THE ARCHITECT IN WRITING OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND/ OR GENERAL NOTES OF WHICH A CONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND MEANS & METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE ARCHITECT PRIOR TO THE OWNER OR OWNER'S CONTRACTOR PROCEEDING WITH THE WORK. THE OWNER WILL BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT FOLLOWED. NOTE: THE ORIGINAL SIZE OF THIS DRAWING SHEET IS: 36"X48" Project Number: SUBMITTAL: REVISION: DATE DESCRIPTION 8/9/2018 3:25:10 PM A0.1 AS-BUILT SITE PLANCLARIZIO REMODEL7401 SEASHORE, NEWPORT BEACH, CALOT 8, BLOCK N, SEASHORE COLONY TRACTPLAN CHECK # 0696-2018CDP SUBMITTALCHRIS CLARIZIO 2017005 03/23/18 BLDG. DEPT. SUBMITTAL 1 06/08/18 BLDG. DEPT. SUBMITTAL 2 06/28/18 BLDG. DEPT. SUBMITTAL 3 08/10/18 CDP SUBMITTAL 3/16" = 1'-0"1 AS-BUILT SITE PLAN NO. DATE DESCRIPTION 18 WH UP W D OVENWH DN 4 A5.0 1 A5.0 2 A5.0 3 A5.0 1 A0.6 2 A0.6 3 A0.6 4 A0.6 18'-6 1/2"5'-5 1/2" 11'-10 1/4"3 1/2"11'-10 1/4" 9'-10 1/4"2'-0" KITCHEN HALL BATH CL. CL. CL. HALL BED 1 BED 2 EXISTING GARAGE EXISTING GARAGE SETBACK3'-0"SETBACK 3'-0"SETBACK5'-0"24'-0"62'-4 1/2"22'-5" UTL. LIVING ROOM2'-2"7'-9"5'-2"4'-10 1/2"4'-7"7'-8 1/2"2'-10 1/2"15'-1"9'-5 1/2"10'-7"2'-10"10'-4 1/2"12'-9"1'-3 1/2"24'-6 1/2"37'-10"5'-8 1/2"1'-4"4'-4"3'-8 1/2"4'-9 1/2"2'-1"1'-5"1'-2"7'-1 1/2"7'-0 1/2"7'-11 1/2"2'-0"7'-11"4'-6"7'-0 1/2"8'-0 1/2"6'-10 1/2"2'-7"14'-2"9'-11 1/2"12'-5"1'-3 1/2"1 A0.3 2 A0.3 3 A0.3 4 A0.3 2'-3"9'-3 3/4"6'-7 1/2"3'-9"8'-4"4'-5"ALLEY SEASHORE DRIVEOLIVE ST4 A5.0 1 A5.0 2 A5.0 3 A5.0 1 A0.6 2 A0.6 3 A0.6 4 A0.6 12'-0"12'-0" 24'-0"62'-4 1/2"15'-0"47'-4 1/2"7'-6 1/2"8'-11"7'-6 1/2" BATH 1 BED 2 BED 3 CL.CL. 4'-7 1/4"4'-3 3/4"SETBACK3'-0"SETBACK 3'-0" SETBACK 3'-0"SETBACK5'-0"CL. BED 1 KITCHEN LIVING ROOM ROOF DECK 2'-1 7/8"2'-5 3/8"2'-1 7/8"2'-1 7/8"2'-5"7'-11 1/2"4'-1 1/2"5'-3 1/2"7'-0 1/2"4'-6 1/2"8'-4 5/8"4'-3 7/8"8'-10 11/256"6'-1 245/256"3'-3 1/2"10'-4 1/2"9'-5"11'-7"12'-8 1/2"47'-4 1/2"15'-0"62'-4 1/2"2'-6"11'-6"4'-11"5'-7"3'-3 1/2"14'-0"10'-6"2'-11"16'-8"15'-0"10'-0 5/8"1'-11 3/8" 1 A0.3 2 A0.3 3 A0.3 4 A0.3 8'-2 1/2"6'-9 1/2"3'-6 1/2"5'-4"3'-3 1/4"1'-11 1/4"5'-7 1/2"4'-3 1/2" 6'-2 3/4"2'-6"3'-5"11'-10 1/4" 6'-6 3/4"2'-2" CLIENT: LICENCE STAMP: PROJECT TEAM: CONTACT: E-MAIL: E-MAIL: PRINCIPAL: PROJECT DIRECTOR: PROJECT DESIGNER: HOMER OATMAN hoatman@oatmanarchitects.com cadams@oatmanarchitects.com HOMER OATMAN CORY ADAMS BEHTASH AZAR THESE DRAWINGS ARE THE PROPERTY OF OATMAN ARCHITECTS AND SHALL NOT BE MODIFIED OR USED ON ANY OTHER PROJECT OR SITE WITHOUT WRITTEN PERMISSION. IT IS THE OWNER'S AND IT'S GENERAL CONTRACTOR'S RESPONSIBILITY, PRIOR TO OR DURING CONSTRUCTION, TO NOTIFY THE ARCHITECT IN WRITING OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND/ OR GENERAL NOTES OF WHICH A CONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND MEANS & METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE ARCHITECT PRIOR TO THE OWNER OR OWNER'S CONTRACTOR PROCEEDING WITH THE WORK. THE OWNER WILL BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT FOLLOWED. NOTE: THE ORIGINAL SIZE OF THIS DRAWING SHEET IS: 36"X48" Project Number: SUBMITTAL: REVISION: DATE DESCRIPTION 8/9/2018 3:25:13 PM A0.2 AS BUILT PLANSCLARIZIO REMODEL7401 SEASHORE, NEWPORT BEACH, CALOT 8, BLOCK N, SEASHORE COLONY TRACTPLAN CHECK # 0696-2018CDP SUBMITTALCHRIS CLARIZIO 2017005 03/23/18 BLDG. DEPT. SUBMITTAL 1 06/08/18 BLDG. DEPT. SUBMITTAL 2 06/28/18 BLDG. DEPT. SUBMITTAL 3 08/10/18 CDP SUBMITTAL 1/4" = 1'-0"1 FIRST FLOOR 1/4" = 1'-0"2 SECOND FLOOR NO. DATE DESCRIPTION 19 T.O. SLAB 1ST FL. 13'-9 77/128" T.O. SHTG 2ND FL. 22'-7 77/128" T.O. PLT. 2ND FL. 30'-7 77/128" T.O. PLT. 1ST FL. 21'-9 77/128"8'-0"10"8'-0"17'-10 7/16"EST. GRADE 12.89' EXISTING ROOF 31.67' T.O. SLAB 1ST FL. 13'-9 77/128" T.O. SHTG 2ND FL. 22'-7 77/128" T.O. PLT. 2ND FL. 30'-7 77/128" T.O. PLT. 1ST FL. 21'-9 77/128"8'-0"10"8'-0"17'-10 7/16"T.O. SLAB 1ST FL. 13'-9 77/128" T.O. SHTG 2ND FL. 22'-7 77/128" T.O. PLT. 2ND FL. 30'-7 77/128" T.O. PLT. 1ST FL. 21'-9 77/128"TOP OF EXISTING ROOF18'-9 3/8"8'-0"10"8'-0"EST. GRADE 12.89' EXISTING ROOF 31.67' EXISING BUILDING HEIGHT ABOVE ESTABLISHED GRADE: 31.97' - 12.89' = 18.78' T.O. SLAB 1ST FL. 13'-9 77/128" T.O. SHTG 2ND FL. 22'-7 77/128" T.O. PLT. 2ND FL. 30'-7 77/128" T.O. PLT. 1ST FL. 21'-9 77/128"8'-0"10"8'-0"17'-10 7/16"CLIENT: LICENCE STAMP: PROJECT TEAM: CONTACT: E-MAIL: E-MAIL: PRINCIPAL: PROJECT DIRECTOR: PROJECT DESIGNER: HOMER OATMAN hoatman@oatmanarchitects.com cadams@oatmanarchitects.com HOMER OATMAN CORY ADAMS BEHTASH AZAR THESE DRAWINGS ARE THE PROPERTY OF OATMAN ARCHITECTS AND SHALL NOT BE MODIFIED OR USED ON ANY OTHER PROJECT OR SITE WITHOUT WRITTEN PERMISSION. IT IS THE OWNER'S AND IT'S GENERAL CONTRACTOR'S RESPONSIBILITY, PRIOR TO OR DURING CONSTRUCTION, TO NOTIFY THE ARCHITECT IN WRITING OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND/ OR GENERAL NOTES OF WHICH A CONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND MEANS & METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE ARCHITECT PRIOR TO THE OWNER OR OWNER'S CONTRACTOR PROCEEDING WITH THE WORK. THE OWNER WILL BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT FOLLOWED. NOTE: THE ORIGINAL SIZE OF THIS DRAWING SHEET IS: 36"X48" Project Number: SUBMITTAL: REVISION: DATE DESCRIPTION 8/9/2018 3:25:31 PM A0.3 AS-BUILT ELEVATIONSCLARIZIO REMODEL7401 SEASHORE, NEWPORT BEACH, CALOT 8, BLOCK N, SEASHORE COLONY TRACTPLAN CHECK # 0696-2018CDP SUBMITTALCHRIS CLARIZIO 2017005 03/23/18 BLDG. DEPT. SUBMITTAL 1 06/08/18 BLDG. DEPT. SUBMITTAL 2 06/28/18 BLDG. DEPT. SUBMITTAL 3 08/10/18 CDP SUBMITTAL 1/4" = 1'-0"2 AS-BUILT_LEFT 1/4" = 1'-0"4 AS BUILT_RIGHT 1/4" = 1'-0"1 AS-BUILT_FRONT 1/4" = 1'-0"3 AS BUILT_REAR NO. DATE DESCRIPTION A 06/08/18 PLAN CHECK CORRECTIONS B 06/28/18 PLAN CHECK CORRECTIONS 20 N 36°54'04" E86.00'N 36°54'04" E84.90'N 5 5°1 2'3 8" W 3 0.0 2'N 53°05'56" W30.00'7.50'7.50'LOT 8, BLOCKNSEASHORE COLONYTRACTLOT 7OLIVE STREETSEASHORE DRIVEA L L E Y E xistin g re sid e n ce TR1TR101Edison manholeTR4Sewer manholeSewer COWater valveFire hydrantW a te r v a lv e TR3Sewer COWater meterElectric boxG a s m e te rEXISTING CONCRETE TO BE DEMOLISHED EXISTING CMU WALL TO BE DEMOLISHED REPLACE EXISTING CLAY & CAST IRON SEWER LINE SITE DEMO LEGEND PROPERTY LINE MINIMUM BUILDING SETBACK LINE EXISTING WALLS TO BE REMOVED EXISING CONCRETE TO BE REMOVED EXISTING CONCRETE NOTE: 1. THERE SHALL BE NO TRENCHES OR EXCAVATIONS 5 FEET OR MORE IN DEPTH INTO WHICH A PERSON IS REQUIRED TO DESCEND; OR OBTAIN A NECESSARY PERMIT FROM THE STATE OF CALIFORNIA, DIVISION OF INDUSTRIAL SAFETY PRIOR TO THE ISSUANCE OF A BUILDING OR GRADING PERMIT. 2. FOR SPECIAL INSPECTION FORMS SEE STRUCTURAL DRAWINGS. 3. VERIFY EXACT SIZE, LOCATIONS AND DEPTH (WHERE APPLICABLE) OF ALL EXISTING PIPING, LINES, LATERALS, AND WYES BEFORE STARTING TRENCHING OR ANY OTHER WORK. FIELD VERIFY THAT INVERT ELEVATIONS ARE SUFFICIENT TO MAINTAIN REQUIRED SLOPES. SHOULD IT BE NECESSARY TO REROUTE LINES DUE TO CONDITIONS FOUND ON THE SITE OR IF INDICATED POINT OF CONNECTIONS CAN NOT BE MADE TO THE LINES AS FOUND, THE CONTRACTOR SHALL, BEFORE CONTINUING, NOTIFY THE ARCHITECT PRIOR TO INSTALLING ANY WORK WHICH MAY BE AFFECTED. 4. THE SEWER LINES ARE PRESENTED DIAGRAMMATICLY TO THE EXTENT THAT ALL OFFSETS, BENDS, SPECIAL FITTINGS AND EXACT LOCATIONS ARE NOT INDICATED. LOCATION OF PIPING MAY VARY AS LONG AS INDICATED PIPE SIZES ARE INSTALLED. INSTALL PIPING IN AVAILABLE LOCATIONS. REFER TO PLUMBING DRAWINGS FOR MORE INFORMATION. CLIENT: LICENCE STAMP: PROJECT TEAM: CONTACT: E-MAIL: E-MAIL: PRINCIPAL: PROJECT DIRECTOR: PROJECT DESIGNER: HOMER OATMAN hoatman@oatmanarchitects.com cadams@oatmanarchitects.com HOMER OATMAN CORY ADAMS BEHTASH AZAR THESE DRAWINGS ARE THE PROPERTY OF OATMAN ARCHITECTS AND SHALL NOT BE MODIFIED OR USED ON ANY OTHER PROJECT OR SITE WITHOUT WRITTEN PERMISSION. IT IS THE OWNER'S AND IT'S GENERAL CONTRACTOR'S RESPONSIBILITY, PRIOR TO OR DURING CONSTRUCTION, TO NOTIFY THE ARCHITECT IN WRITING OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND/ OR GENERAL NOTES OF WHICH A CONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND MEANS & METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE ARCHITECT PRIOR TO THE OWNER OR OWNER'S CONTRACTOR PROCEEDING WITH THE WORK. THE OWNER WILL BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT FOLLOWED. NOTE: THE ORIGINAL SIZE OF THIS DRAWING SHEET IS: 36"X48" Project Number: SUBMITTAL: REVISION: DATE DESCRIPTION 8/9/2018 3:25:35 PM A0.4 SITE DEMO PLANCLARIZIO REMODEL7401 SEASHORE, NEWPORT BEACH, CALOT 8, BLOCK N, SEASHORE COLONY TRACTPLAN CHECK # 0696-2018CDP SUBMITTALCHRIS CLARIZIO 2017005 03/23/18 BLDG. DEPT. SUBMITTAL 1 06/08/18 BLDG. DEPT. SUBMITTAL 2 06/28/18 BLDG. DEPT. SUBMITTAL 3 08/10/18 CDP SUBMITTAL 3/16" = 1'-0"1 SITE DEMO PLAN NO. DATE DESCRIPTION 21 WH UP W D OVENWH DN KITCHEN HALL BATH CL. CL. CL. HALL BED 1 BED 2 EXISTING GARAGE EXISTING GARAGE FAMILY ROOM 1 A0.6 2 A0.6 3 A0.6 4 A0.6 ALLEY SEASHORE DRIVEOLIVE STBATH 1 BED 2 BED 3 CL.CL. CL. BED 1 KITCHEN LIVING ROOM ROOF DECK 1 A0.6 2 A0.6 3 A0.6 4 A0.6 DEMO LEGEND EXISTING 2X4 WOOD STUD WALLS DEMOLISHED/REMOVED CLIENT: LICENCE STAMP: PROJECT TEAM: CONTACT: E-MAIL: E-MAIL: PRINCIPAL: PROJECT DIRECTOR: PROJECT DESIGNER: HOMER OATMAN hoatman@oatmanarchitects.com cadams@oatmanarchitects.com HOMER OATMAN CORY ADAMS BEHTASH AZAR THESE DRAWINGS ARE THE PROPERTY OF OATMAN ARCHITECTS AND SHALL NOT BE MODIFIED OR USED ON ANY OTHER PROJECT OR SITE WITHOUT WRITTEN PERMISSION. IT IS THE OWNER'S AND IT'S GENERAL CONTRACTOR'S RESPONSIBILITY, PRIOR TO OR DURING CONSTRUCTION, TO NOTIFY THE ARCHITECT IN WRITING OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND/ OR GENERAL NOTES OF WHICH A CONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND MEANS & METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE ARCHITECT PRIOR TO THE OWNER OR OWNER'S CONTRACTOR PROCEEDING WITH THE WORK. THE OWNER WILL BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT FOLLOWED. NOTE: THE ORIGINAL SIZE OF THIS DRAWING SHEET IS: 36"X48" Project Number: SUBMITTAL: REVISION: DATE DESCRIPTION 8/9/2018 3:25:39 PM A0.5 DEMO PLANCLARIZIO REMODEL7401 SEASHORE, NEWPORT BEACH, CALOT 8, BLOCK N, SEASHORE COLONY TRACTPLAN CHECK # 0696-2018CDP SUBMITTALCHRIS CLARIZIO 2017005 03/23/18 BLDG. DEPT. SUBMITTAL 1 06/08/18 BLDG. DEPT. SUBMITTAL 2 06/28/18 BLDG. DEPT. SUBMITTAL 3 08/10/18 CDP SUBMITTAL 1/4" = 1'-0"1 FIRST FLOOR 1/4" = 1'-0"2 SECOND FLOOR NO. DATE DESCRIPTION 22 T.O. SLAB 1ST FL. 13'-9 77/128" T.O. SHTG 2ND FL. 22'-7 77/128" T.O. PLT. 2ND FL. 30'-7 77/128" T.O. PLT. 1ST FL. 21'-9 77/128" T.O. SLAB 1ST FL. 13'-9 77/128" T.O. SHTG 2ND FL. 22'-7 77/128" T.O. PLT. 2ND FL. 30'-7 77/128" T.O. PLT. 1ST FL. 21'-9 77/128" T.O. SLAB 1ST FL. 13'-9 77/128" T.O. SHTG 2ND FL. 22'-7 77/128" T.O. PLT. 2ND FL. 30'-7 77/128" T.O. PLT. 1ST FL. 21'-9 77/128" T.O. SLAB 1ST FL. 13'-9 77/128" T.O. SHTG 2ND FL. 22'-7 77/128" T.O. PLT. 2ND FL. 30'-7 77/128" T.O. PLT. 1ST FL. 21'-9 77/128" CLIENT: LICENCE STAMP: PROJECT TEAM: CONTACT: E-MAIL: E-MAIL: PRINCIPAL: PROJECT DIRECTOR: PROJECT DESIGNER: HOMER OATMAN hoatman@oatmanarchitects.com cadams@oatmanarchitects.com HOMER OATMAN CORY ADAMS BEHTASH AZAR THESE DRAWINGS ARE THE PROPERTY OF OATMAN ARCHITECTS AND SHALL NOT BE MODIFIED OR USED ON ANY OTHER PROJECT OR SITE WITHOUT WRITTEN PERMISSION. IT IS THE OWNER'S AND IT'S GENERAL CONTRACTOR'S RESPONSIBILITY, PRIOR TO OR DURING CONSTRUCTION, TO NOTIFY THE ARCHITECT IN WRITING OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND/ OR GENERAL NOTES OF WHICH A CONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND MEANS & METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE ARCHITECT PRIOR TO THE OWNER OR OWNER'S CONTRACTOR PROCEEDING WITH THE WORK. THE OWNER WILL BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT FOLLOWED. NOTE: THE ORIGINAL SIZE OF THIS DRAWING SHEET IS: 36"X48" Project Number: SUBMITTAL: REVISION: DATE DESCRIPTION 8/9/2018 3:25:52 PM A0.6 DEMO ELEVATIONSCLARIZIO REMODEL7401 SEASHORE, NEWPORT BEACH, CALOT 8, BLOCK N, SEASHORE COLONY TRACTPLAN CHECK # 0696-2018CDP SUBMITTALCHRIS CLARIZIO 2017005 03/23/18 BLDG. DEPT. SUBMITTAL 1 06/08/18 BLDG. DEPT. SUBMITTAL 2 06/28/18 BLDG. DEPT. SUBMITTAL 3 08/10/18 CDP SUBMITTAL 1/4" = 1'-0"1 DEMO_FRONT 1/4" = 1'-0"3 DEMO_REAR 1/4" = 1'-0"2 DEMO_LEFT 1/4" = 1'-0"4 DEMO_RIGHT NO. DATE DESCRIPTION 23 N 36°54'04" E86.00'N 36°54'04" E84.90'N 5 5°1 2'3 8" W 3 0.0 2'N 53°05'56" W30.00'LOT 7OLIVE STREETSEASHORE DRIVEA L L E Y TR1TR101Edison manholeTR4Sewer manholeSewer COWater valveFire hydrantW a te r v a lv e TR3Sewer COWater meterElectric boxG a s m e te rSITE LEGEND PROPERTY LINE MINIMUM BUILDING SETBACK LINE PER EXHIBIT 'A' NOTE: 1. THERE SHALL BE NO TRENCHES OR EXCAVATIONS 5 FEET OR MORE IN DEPTH INTO WHICH A PERSON IS REQUIRED TO DESCEND; OR OBTAIN A NECESSARY PERMIT FROM THE STATE OF CALIFORNIA, DIVISION OF INDUSTRIAL SAFETY PRIOR TO THE ISSUANCE OF A BUILDING OR GRADING PERMIT. 2. FOR SPECIAL INSPECTION FORMS SEE STRUCTURAL DRAWINGS. 3. VERIFY EXACT SIZE, LOCATIONS AND DEPTH (WHERE APPLICABLE) OF ALL EXISTING PIPING, LINES, LATERALS, AND WYES BEFORE STARTING TRENCHING OR ANY OTHER WORK. FIELD VERIFY THAT INVERT ELEVATIONS ARE SUFFICIENT TO MAINTAIN REQUIRED SLOPES. SHOULD IT BE NECESSARY TO REROUTE LINES DUE TO CONDITIONS FOUND ON THE SITE OR IF INDICATED POINT OF CONNECTIONS CAN NOT BE MADE TO THE LINES AS FOUND, THE CONTRACTOR SHALL, BEFORE CONTINUING, NOTIFY THE ARCHITECT PRIOR TO INSTALLING ANY WORK WHICH MAY BE AFFECTED. 4. THE SEWER LINES ARE PRESENTED DIAGRAMMATICLY TO THE EXTENT THAT ALL OFFSETS, BENDS, SPECIAL FITTINGS AND EXACT LOCATIONS ARE NOT INDICATED. LOCATION OF PIPING MAY VARY AS LONG AS INDICATED PIPE SIZES ARE INSTALLED. INSTALL PIPING IN AVAILABLE LOCATIONS. REFER TO PLUMBING DRAWINGS FOR MORE INFORMATION. FOR FURTHER INFORMATION UNDER SEPARATE PERMITS, SEE: • GRADING #: • RETAINING WALLS #: • LANDSCAPE #: FIRE HYDRANT WATER VALVE FH WV SITE PLAN NOTES 1. ALL SETBACKS DIMENSIONED FROM PROPERTY LINE TO FACE OF FINISH. 2. SEE TOPOGRAPHIC SURVEY (SHEET C-5) FOR EXISTING TOP OF WALL ELEVATIONS . VICINITY MAP T O FINIS H 3'-1" T O FINIS H 3'-0". T O FINIS H 3'-0".TO FINISH3'-7 7/8"EXISTING ROOF & STRUCTURE SETBACK5'-0"15'-0"15'-0" CLIENT: LICENCE STAMP: PROJECT TEAM: CONTACT: E-MAIL: E-MAIL: PRINCIPAL: PROJECT DIRECTOR: PROJECT DESIGNER: HOMER OATMAN hoatman@oatmanarchitects.com cadams@oatmanarchitects.com HOMER OATMAN CORY ADAMS BEHTASH AZAR THESE DRAWINGS ARE THE PROPERTY OF OATMAN ARCHITECTS AND SHALL NOT BE MODIFIED OR USED ON ANY OTHER PROJECT OR SITE WITHOUT WRITTEN PERMISSION. IT IS THE OWNER'S AND IT'S GENERAL CONTRACTOR'S RESPONSIBILITY, PRIOR TO OR DURING CONSTRUCTION, TO NOTIFY THE ARCHITECT IN WRITING OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND/ OR GENERAL NOTES OF WHICH A CONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND MEANS & METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE ARCHITECT PRIOR TO THE OWNER OR OWNER'S CONTRACTOR PROCEEDING WITH THE WORK. THE OWNER WILL BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT FOLLOWED. NOTE: THE ORIGINAL SIZE OF THIS DRAWING SHEET IS: 36"X48" Project Number: SUBMITTAL: REVISION: DATE DESCRIPTION 8/9/2018 3:25:56 PM A1.0 ARCHITECTURAL SITE PLANCLARIZIO REMODEL7401 SEASHORE, NEWPORT BEACH, CALOT 8, BLOCK N, SEASHORE COLONY TRACTPLAN CHECK # 0696-2018CDP SUBMITTALCHRIS CLARIZIO 2017005 03/23/18 BLDG. DEPT. SUBMITTAL 1 06/08/18 BLDG. DEPT. SUBMITTAL 2 06/28/18 BLDG. DEPT. SUBMITTAL 3 08/10/18 CDP SUBMITTAL 3/16" = 1'-0"1 SITE TRUE NORTHNORTHSEE GRADING PLANS FOR ADDITIONAL INFORMATION. ELEV. 12.95' ELEV. 13.17' ELEV. 12.53' ELEV. 12.92' ESTABLISHED GRAD CALCULATION 12.95' + 13.17' + 12.53' + 12.92' = 51.57' / 4 = 12.89' NO. DATE DESCRIPTION A 06/08/18 PLAN CHECK CORRECTIONS B 06/28/18 PLAN CHECK CORRECTIONS 24 SLAB PLAN NOTES 1. THIS PLAN IS FOR REFERENCE ONLY. 2. COMPARE AND VERIFY SLAB ELEVATIONS VARIATIONS AS SHOWN ON THE BASEMENT AND FIRST FLOOR PLANS PRIOR TO AND DURING CONSTRUCTIONS. 3. COMPARE AND VERIFY ALL DIMESIONS AS SHOWN ON THE BASEMENT AND FIRST FLOOR PLANS PRIOR TO AND DURING CONSTRUCTIONS. 4. COMPARE AND VERIFY ALL EXTERIOR WALL THICKNESS AND EXTERIOR DOOR ROUGH OPENING SIZES IN RELATION TO THE END OF SLAB AND PERIMETER CURB PRIOR TO CONSTRUCTION. 5. COMPARE AND VERIFY ALL EXTERIOR DOOR DEPRESSIONS IN RELATION TO EXTERIOR DOOR ROUGH OPENING SIZES PER MANUFACTURER'S SPECIFICATIONS PRIOR TO CONSTRUCTION. 6. COMPARE AND VERIFY ALL HARDSCPE CONDITIONS IN RELATION TO THE ENDE OF SLAB AND PERIMETER CURB PRIOR TO CONSTRUCTION. 7. ANY DEVIATIONS OR DISCREPANCIES SHALL BE FORWARDED TO THE ARCHITECT. SLAB PLAN LEGEND NEW 6" X 6" CONC. CURB, U.N.O. POURED CONC. SLAB, SEE STRUCT. DEPRESSED SLAB AREA AND DEPTH DIMENSION1 1/2"CLIENT: LICENCE STAMP: PROJECT TEAM: CONTACT: E-MAIL: E-MAIL: PRINCIPAL: PROJECT DIRECTOR: PROJECT DESIGNER: HOMER OATMAN hoatman@oatmanarchitects.com cadams@oatmanarchitects.com HOMER OATMAN CORY ADAMS BEHTASH AZAR THESE DRAWINGS ARE THE PROPERTY OF OATMAN ARCHITECTS AND SHALL NOT BE MODIFIED OR USED ON ANY OTHER PROJECT OR SITE WITHOUT WRITTEN PERMISSION. IT IS THE OWNER'S AND IT'S GENERAL CONTRACTOR'S RESPONSIBILITY, PRIOR TO OR DURING CONSTRUCTION, TO NOTIFY THE ARCHITECT IN WRITING OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND/ OR GENERAL NOTES OF WHICH A CONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND MEANS & METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE ARCHITECT PRIOR TO THE OWNER OR OWNER'S CONTRACTOR PROCEEDING WITH THE WORK. THE OWNER WILL BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT FOLLOWED. NOTE: THE ORIGINAL SIZE OF THIS DRAWING SHEET IS: 36"X48" Project Number: SUBMITTAL: REVISION: DATE DESCRIPTION 8/9/2018 3:25:59 PM A2.0 SLAB PLANCLARIZIO REMODEL7401 SEASHORE, NEWPORT BEACH, CALOT 8, BLOCK N, SEASHORE COLONY TRACTPLAN CHECK # 0696-2018CDP SUBMITTALCHRIS CLARIZIO 2017005 03/23/18 BLDG. DEPT. SUBMITTAL 1 06/08/18 BLDG. DEPT. SUBMITTAL 2 06/28/18 BLDG. DEPT. SUBMITTAL 3 08/10/18 CDP SUBMITTAL NO. DATE DESCRIPTION 25 DN WH UP FLOOR PLAN LEGEND 2x8 WOOD STUD WALLS CONC. WALL, REFER TO STRUCTURAL 2x4 WOOD STUD WALLS XXXX 1 DOOR TAG WINDOW TAG KEYNOTE ELEVATION CALLOUTA101 1 Ref 1 Ref1 Ref 1 Ref101 EXISTING 2X4 WOOD STUD WALLS EGRESS WINDOW SEE NOTE 11 TEMPERED GLASS FLOOR PLAN NOTES 1. DO NOT SCALE DRAWINGS. 2. REFER TO GENERAL NOTES FOR ADDITIONAL REQUIRED INFORMATION. 3. REFER TO INTERIOR DESIGN DRAWINGS FOR ALL PLUMBING FIXTURES, APPLIANCES, CABINETS, AND INTERIOR FINISH SCHEDULES. VERIFY DIMENSIONS OF ALL PLUMBING FIXTURES AND APPLIANCES WITH MFGR. SPECIFICATIONS AND COORDINATE WITH CABINET INSTALLER. 4. REFER TO INTERIOR DESIGN DRAWINGS FOR LOCATION(S) AND HEIGHT(S) OF ALL ART NICHES AND BATHROOM ACCESSORIES (I.E. TOWEL BARS, TOILET PAPER DISPENSERS, MIRRORS. . .ETC). PROVIDE 2X BLOCKING FOR NECESSARY SUPPORT. 5. REFER TO STRUCTURAL DRAWINGS FOR ALL FOUNDATION AND FRAMING REQUIREMENTS ALONG WITH ANY CITY REQUIRED STRUCTURAL OBSERVATION(S) AND SPECIAL INSPECTION CERTIFICATION(S), PER THE COUNTY OF ORANGE. 6. REFER TO LANDSCAPE ARCHITECT DRAWINGS FOR EXTERIOR DOOR LANDING(S) AND STOOP(S). PROVIDE A MIN. 36" IN DIRECTION OF TRAVEL. SLOPE AWAY 1/4" PER 12" FOR DRAINAGE. DOORS LANDINGS TO COMPLY WITH C.R.C SECTION R311.3. 7. REFER TO THE REFLECTED CEILING PLANS FOR CEILING AND SOFFIT HEIGHTS. 8. REFER TO PLANS FOR ALL DOOR AND WINDOW TYPES, SIZES, AND REQUIRED LOCATION(S) OF GLAZING WHICH ARE TO BE DUAL GLAZED WITH A MINIMUM OF ON PANE BEING TEMPERED AS REQUIRED PER C.R.C. SECTION R327.8. SEE ADDITIONAL LOCATIONS AND INFORMATION LISTED IN C.R.C. SECTION R308. 9. REFER TO SHEET (T-24.0) FOR THE TITLE-24 ENERGY CALCULATION FORMS AND MANDATORY REQUIREMENTS (CF-1R AND MF-1R) FOR ENERGY COMPLIANCE. FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT LABELS. 10. PLUMBING FIXTURE REQUIREMENTS AND FLOW RATES PER C.G.B.S.C TABLE 4.303.2: A. ALL WATER CLOSETS AND ASSOCIATED FLUSHOMETER VALVES SHALL HAVE A MAXIMUM FLOW RATE OF 1.28 G.P.F. AND SHALL MEET PERFORMANCE STANDARDS ESTABLISHED BY THE AMERICAN NATIONAL STANDARDS H. & S. CODE, SECTION 17921.3(b) AND BY THE CALIFORNIA ENERGY COMMISSION. PROVIDE A MIN. CLEAR FLOOR SPACE OF 30" WIDE X 24" DEEP CLEAR IN FRONT AND CENTERED ON WATER CLOSET PER C.P.C. B. ALL SHOWER HEADS SHALL HAVE A MAXIMUM FLOW RATE OF 2.0 G.P.M. @ 80 P.S.I. PER STANDARDS SET BY THE CALIFORNIA ENERGY COMMISSION. CONTROL VALVES TO BE PRESSURE BALANCED OR THERMOSTATIC MIXING, PER C.P.C. SECTION 418. THE COMBINED FLOW OF MULTIPLE SHOWER HEADS SERVING A SINGLE SHOWER SHALL NOT EXCEED MAXIMUM ALLOWABLE FLOW RATE FOR A SINGLE FIXTURE SHOWER OR THE CONTROL VALVES SHALL BE ARRANGED TO ONLY ALLOW ONE SHOWER HEAD TO OPERATE AT A TIME. C. LAUNDRY FAUCETS SHALL HAVE A MAXIMUM FLOW RATE OF 1.8 G.P.M. @ 60 P.S.I. PER STANDARDS SET BY THE CALIFORNIA ENERGY COMMISSION. D. ALL KITCHEN (SINK) FAUCETS SHALL HAVE A MAXIMUM FLOW RATE OF 1.8 G.P.M. @ 60 P.S.I. PER STANDARDS SET BY THE CALIFORNIA ENERGY COMMISSION. E. ALL LAVATORY (SINK) FAUCETS SHALL HAVE A MAXIMUM FLOW RATE OF 1.5 G.P.M. @ 60 P.S.I. PER STANDARDS SET BY THE CALIFORNIA ENERGY COMMISSION. 11. SLEEPING ROOMS SHALL HAVE A WINDOW OR EXTERIOR DOOR FOR EMERGENCY ESCAPE. SILL HEIGHT SHALL NOT EXCEED 44" ABOVE THE FLOOR. WINDOWS MUST HAVE AN OPENABLE AREA OF AT LEAST 5.7 SQ. FT. WITH THE MINIMUM OPENABLE WIDTH OF 20" AND THE MINIMUM OPENABLE HEIGHT OF 24". THE EMERGENCY DOOR OR WINDOW SHALL BE OPENABLE FROM THE INSIDE TO PROVIDE A FULL, CLEAR OPENING WITHOUT THE USE OF KEYS, TOOLS, OR SPECIAL KNOWLEDGE, PER C.R.C. SECTION R310. 12. THE OPENING OF THE SILL PORTION OF AN OPERABLE WINDOW LOCATED MORE THAN 72" ABOVE FINISH GRADE SHALL BE A MINIMUM OF 24" ABOVE THE FINISH FLOOR. GLAZING BETWEEN THE FLOOR AND A HEIGHT OF 24" SHALL BE FIXED OR A HAVE OPENING SUCH THAT A 4" DIAMETER SPHERE CANNOT PASS, PER C.R.C. SECTION R612.2; OR BE PROVIDED WITH A WINDOW GUARD THAT COMPLIES WITH ASTM F 2090. 13. SHOWER COMPARTMENTS AND WALLS ABOVE BATHTUBS WITH INSTALLED SHOWER HEADS SHALL BE FINISHED WITH A SMOOTH, NONABSORBENT SURFACE TO A HEIGHT OF NOT LESS THAN 72" ABOVE THE DRAIN INLET, PER C.R.C SECTION R307.2. 14. THE NET AREA OF THE SHOWER ENCLOSURE(S) SHALL BE 1,024 SQ. INCHES (7.1 S.F.) OR MORE IN CLEAR FLOOR AREA, AND SHALL ALSO BE CAPABLE OF ENCOMPASSING A 30" DIAMETER CIRCLE, PER C.P.C SECTION 411.7. 15. EXTERIOR HOSE BIBBS AND LAWN SPRINKLER SYSTEM SHALL HAVE AN APPROVED NON-REMOVABLE BACKFLOW PREVENTION DEVICE, PER C.P.C. SECTION 603. 16. ALL HABITABLE SPACES INTENDED FOR HUMAN OCCUPANCY SHALL COMPLY WITH C.R.C. SECTION R303 FOR NATURAL VENTILATION AND LIGHTING AND CONTAIN GLAZING NOT LESS THAN 8% OF THE FLOOR AREA OF THE ROOM. NATURAL VENTILATION SHALL BE THROUGH WINDOWS, DOORS, LOUVERS OR OTHER APPROVED OPENINGS TO THE OUTDOOR AIR. SUCH OPENINGS SHALL BE PROVIDED WITH READY ACCESS OR SHALL OTHERWISE BE READILY CONTROLLABLE BY THE BUILDING OCCUPANTS. THE MINIMUM OPEN ABLE AREA TO THE OUTDOORS SHALL BE 4 PERCENT OF THE FLOOR AREA BEING VENTILATED. A. BATHROOMS, WATER CLOSET COMPARTMENTS AND OTHER SIMILAR ROOMS SHALL BE PROVIDED WITH AGGREGATE GLAZING AREA IN WINDOWS OF NOT LESS THAN 3 SQUARE FEET, ONE-HALF OF WHICH MUST BE OPENABLE. EXCEPTION: THE GLAZED AREAS SHALL NOT BE REQUIRED WHERE ARTIFICIAL LIGHT AND A LOCAL EXHAUST SYSTEM ARE PROVIDED. THE MINIMUM LOCAL EXHAUST RATES SHALL BE 50 CU. FT. PER MINUTE. 17. PROVIDE 5/8" TYPE "X" GYP. BOARD AT WALLS AND CEILING AT USABLE SPACE UNDER STAIRS BEYOND MIN. REQ., PER C.R.C. SECTION R302.7. 18. AT ALL AREAS BETWEEN THE PRIVATE GARAGE (S-2) AND LIVING (R-3) WALLS, PROVIDE A MINIMUM OF 5/8" TYPE "X" GYP. BOARD ON GARAGE SIDE OF WALLS ADJACENT TO LIVING AREAS AND AT ELEMENTS SUPPORTING SEPARATION ABOVE. CEILINGS SHALL RECEIVE A MINIMUM OF 2 LAYERS OF 5/8" TYPE "X" GYP. BOARD ON 16" SPACED JOISTS, TRUSSES, OR R.C. CHANNEL BASED ON OCCUPANCY SEPARATION, PER C.R.C. SECTION R302.6. 19. ALL INTERIOR WALL FINISHES SHALL COMPLY WITH C.R.C. SECTION R702. INSPECTION OF NAILING IS REQUIRED FOR ALL DRYWALL AND LATH WHEN IN PLACE. CORNER BEADS ARE TO BE NAILED. DRYWALL BOARD SHALL BE SPACED AT A MAXIMUM OF 3/8". 20. A MINIMUM OF TWO LAYERS OF GRADE "D" BUILDING PAPER SHALL BE APPLIED OVER ALL WOOD BASE SHEATHING PER C.R.C SECTION R703.6.3. 21. DOORS THAT PROVIDE DIRECT ACCESS TO THE SWIMMING POOL SHALL BE PROVIDED WITH A BARRIER COMPLIANT WITH STATE AND LOCAL POOL BARRIER ORDINANCE. THE MOST STRINGENT CODE REQUIREMENT SHALL PREVAIL. 22. INSULATION: - ROOF/ CEILINGS (R-38) - EXTERIOR WALLS, INCL. FURRED BASEMENT WALLS (R-19) - FRAMED FLOORS (R-30) - BATHROOM AND LAUNDRY ROOM INTERIOR WALLS (R-13) **USE ABOVE NOTED VALUES IF GREATER THAN TITLE-24 MINIMUMS. 22. 23. HANDRAILS SHALL BE CONTINUOUS THE FULL LENGTH OF THE FLIGHT OF STAIRS. HANDRAIL ENDS SHALL BE RETURNED OR TERMINATE INTO POSTS. 24. ALL FIREPLACES TO BE GAS BURNING, DIRECT VENTING SEALED COMBUSTION FIREBOXES. WOOD BURNING FIREPLACES ARE NOT ALLOWED PER AQMD AND THE COUNTY OF ORANGE. 25. ALL THROUGH PENETRATIONS OF REQUIRED FIRE-RESISTIVE CONSTRUCTION SHALL BE IN ACCORDANCE OF C.R.C. R302.4.1.1 or C.R.C. R302.4.1.2. 26. FIREBLOCKING IS REQUIRED IN CONCEALED SPACES 10'-0" O.C. HORIZONTAL, VERTICALLY AT THE CEILING AND FLOOR LEVELS, CONNECTIONS BETWEEN HORIZONTAL AND VERTICAL SPACES, CONCEALED SPACES BETWEEN STAIR AND LANDINGS, OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES, WIRES, CHIMNEYS AND FIREPLACES PER C.R.C. R302.11. 27. PROVIDE SOLID 2X6 BLOCKING IN FRAMING AT TOWEL BAR, HANDRAIL ATTACHMENT, BATH ACCESSORIES, WALL CABINET LOCATIONS. COORDINATE LOCATIONS WITH INTERIOR DESIGNER DRAWINGS. 28. THE CONTRACTOR SHALL INSTALL DRAFT STOPPING TO SUBDIVIDE ATTIC SPACES AND CONCEALED ROOF SPACES, SUCH THAT ANY HORIZONTAL AREA DOES NOT EXCEED 1,000 S.F., OR PER MIN. REQUIREMENTS OF C.R.C SECTION 302.12. DRAFTSTOP MATERIALS TO BE NO LESS THAN 1/2" GYP. BD. OR 3/8" PLYWOOD INSTALLED PARALLEL TO FLOOR AND ROOF FRAMING. 29. SOUND INSULATION NOTES: A. APPROVED ACOUSTICAL SEALANT SHALL BE PROVIDED ALONG THE JOINT BETWEEN THE FLOOR AND THE SEPARATION WALL. B. ALL PENETRATIONS INTO SOUND-RATED PARTITIONS OF FLOOR-CEILING ASSEMBLIES SHALL BE SEALED WITH APPROVED PERMANENT RESILIENT SEALANT. C. ALL RIDGID CONDUIT, DUCTS, PLUMBING PIPES AND APPLIANCE VENTS LOCATED IN SOUND ASSEMBLIES SHALL BE ISOLOATED FROM THE BUILDING CONSTRUCTION BY MEANS OF RESILIENT SLEEVED, MOUNTS OR MINIMUM 1/4" THICK APPROVED RESILKIENT MATERIAL. EXCEPTION: GAS PIPING NEED NOT BE ISOLATED. D. METAL VENTILATING AND CONDITIONED AIR DUCTS LOCATED IN SOUND ASSEMBLIES SHALL BE LINED. E. MINERAL FIBER INSULATION SHALL BE INSTALLED IN JOIST SPACES TO A POINT 12" BEYOND THE PIPE OR DUCT, WHENEVER A PLUMBING PIPE OR DUCT PENETRATES A FLOOR-CEILING ASSEMBLY OR WHERE SUCH UNIT PASSES THROUGH THE PLANE OF THE FLOOR CEILING ASSEMBLY WITHIN A WALL. 4 A5.0 1 A5.0 2 A5.0 3 A5.0 24'-0" LIVING ROOM BATH 1 BATH2 BED 2 BED 3 CL.CL. BATH 3 TO FINISH 3'-0"SETBACK5'-0"BATH 4 BED 4 BED 3 LAUNDRY KITCHEN DECK CL. 13'-5"10'-7" BED 5 CL.1'-2 1/2"12'-6"1'-1 1/2"12'-7"10'-10 1/2"10'-3 1/2"74'-8"3'-0"14'-10"56'-10"8'-4 1/2"1'-10"2'-3 1/2"1'-0"12'-5"3'-3 1/2"2'-0"2'-0"3'-3 1/2"13'-8 1/2"6'-3 1/2"12'-9"5'-9"5'-5 1/2"2'-11"10'-6"TO FINISH 3'-0" 1 A6.0 1 A6.0 2 A6.0 2 A6.0 3 A6.0 3 A6.0 4 A6.0 4 A6.0 14'-4"9'-8" 12'-5 3/4"3'-4"8'-2 1/4" 11'-10 1/4"4'-3 1/2"4'-3 1/4"3'-7"2'-3 1/2"6'-10 1/2"6'-6 1/2"5'-0"5'-7" 2868 2468 246826682468 3070 4068 2668 2668 2668 2268 4068 2041 2041 2041 2024 2024 2024 2941 2924 2941 2924 2941 2924 2941 2924 2941 2924 2941 2924 120702'-1"3'-0 1/2"3'-0 1/2"3'-0 1/2"1'-4 1/2"1'-8"3'-0 1/2"6'-2"9'-11"3'-8 7/8"CSMT CSMT CSMT REPLACE WITH CASEMENT FOR EGRESS REPLACE WITH 4030 CASEMENT FOR EGRESS REPLACE WITH 4030 CASEMENT FOR EGRESS2'-6 1/4"3'-3 1/2"3'-0"22.07 22.05 22.08 22.01 22.05 12.01 22.05 12.01 22.07 22.08 22.07 12.01 22.05 22.05 22.08 11.01 12.01 11.1311.06 12.04 12.02 12.02 16 11 16 11 16 11 16 11 16 11 EXISTING EXISTING EXISTING 3'-4" 11.19 DOOR 3'-0" 3 D3.0 11 D2.0 16 D1.0 1 D3.0 1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"4 A5.0 1 A5.0 2 A5.0 3 A5.0 24'-0" BED 3 KITCHEN HALL BATH CL. CL. CL. HALL BED 1 BED 2 EXISTING GARAGE EXISTING GARAGE TO FINISH3'-0".TO FINISH 3'-0". 24'-0" 1'-0"12'-5"1'-0"8'-7"1'-0"1'-3"3'-8"9'-9 1/2"9'-8"5'-0 1/2"4'-7 1/2"1'-0"23'-0"SETBACK5'-0"1 A6.0 1 A6.0 2 A6.0 2 A6.0 3 A6.0 3 A6.0 4 A6.0 4 A6.0 EXTERIOR PARKING8'-0"18'-4 1/2"1'-3"8'-7"8 1/2"3'-8 1/2"1'-2 1/2"33'-10"12'-1 1/2"11'-10 1/2"12'-8 1/2"3'-3 1/2"2468 2668 4076 2068 REPLACE WITH 3040 CASEMENT FOR EGRESS 8670 ALLEY SEASHORE DRIVEOLIVE ST2 D3.0 A/C A/C TO FINISH 3'-0". 11.01 22.01 12.01 11.06 11.19 9'-0 3/4" Clear9'-2"20'-3 5/8"2'-0 1/8"9'-3 1/4" CLEAR9'-4 1/2"9'-8 1/2"8670 AUTOMATIC ROLL-UP AUTOMATIC ROLL-UP 16 11 T R T KEYNOTES CLIENT: LICENCE STAMP: PROJECT TEAM: CONTACT: E-MAIL: E-MAIL: PRINCIPAL: PROJECT DIRECTOR: PROJECT DESIGNER: HOMER OATMAN hoatman@oatmanarchitects.com cadams@oatmanarchitects.com HOMER OATMAN CORY ADAMS BEHTASH AZAR THESE DRAWINGS ARE THE PROPERTY OF OATMAN ARCHITECTS AND SHALL NOT BE MODIFIED OR USED ON ANY OTHER PROJECT OR SITE WITHOUT WRITTEN PERMISSION. IT IS THE OWNER'S AND IT'S GENERAL CONTRACTOR'S RESPONSIBILITY, PRIOR TO OR DURING CONSTRUCTION, TO NOTIFY THE ARCHITECT IN WRITING OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND/ OR GENERAL NOTES OF WHICH A CONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND MEANS & METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE ARCHITECT PRIOR TO THE OWNER OR OWNER'S CONTRACTOR PROCEEDING WITH THE WORK. THE OWNER WILL BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT FOLLOWED. NOTE: THE ORIGINAL SIZE OF THIS DRAWING SHEET IS: 36"X48" Project Number: SUBMITTAL: REVISION: DATE DESCRIPTION 8/9/2018 3:26:02 PM A3.0 FLOOR PLANSCLARIZIO REMODEL7401 SEASHORE, NEWPORT BEACH, CALOT 8, BLOCK N, SEASHORE COLONY TRACTPLAN CHECK # 0696-2018CDP SUBMITTALCHRIS CLARIZIO 2017005 03/23/18 BLDG. DEPT. SUBMITTAL 1 06/08/18 BLDG. DEPT. SUBMITTAL 2 06/28/18 BLDG. DEPT. SUBMITTAL 3 08/10/18 CDP SUBMITTAL 1/4" = 1'-0"2 SECOND FLOOR 1/4" = 1'-0"1 FIRST FLOOR 11.01 GAS RANGE WITH INTERMITTENT IGNITION DEVICE & HOOD, LIGHT AND VENT ABOVE. 11.06 UNDER-COUNTER DISHWASHER, MFGR SPEC PER OWNER. 11.13 MICROWAVE, MFGR SPEC PER I.D. 11.19 REFRIGERATOR AND FREEZER WITH ICE MAKER, SIZE AND MFGR SPEC PER I.D. 12.01 BUILT-IN CABINETS/SHELVES/STORAGE. MILLWORK PER I.D. 12.02 BUILT-IN CLOSET ORGANIZERS BY OTHERS, FINISH AND HEIGHT BY I.D. 12.04 COUNTERTOP, SIZE AND MATERIAL PER I.D. 22.01 KITCHEN SINK WITH GARBAGE DISPOSAL AND AIR GAP FOR DISHWASHER, MFGR SPEC PER OWNER. REFER TO FLOOR PLAN NOTE #10 (D) FOR KITCHEN SINK FACET FLOW RATE. 22.05 LAVATORY SINK, MFGR SPEC PER OWNER. REFER TO FLOOR PLAN NOTES #10 (D) FROM SINK FACET FLOW RATE. 22.07 WATER CLOSET, MFGR SPEC PER OWNER, REFER TO FLOOR PLAN NOTE #10 (A) FOR FLUSH FLOW RATE AND CLEARANCE 22.08 HOT MOP SHOWER, PROVIDE FULL HEIGHT TILE/STONE SURROUND OVER EXPANDED METAL LATH AND MUD SET PER INTERIOR DESIGNER REFER TO FLOOR PLAN NOTE #10 (B) FOR SHOWER HEAD FLOW RATE. SHOWER HEAD HEIGHT AND LOCATION PER I.D, 100 CFM MINIMUM. NO. DATE DESCRIPTION A 06/08/18 PLAN CHECK CORRECTIONS B 06/28/18 PLAN CHECK CORRECTIONS 26 WH GROSS BUILDING AREAS 89 SF FIRST FLOOR KITCHEN REMODEL 160 SF FIRST FLOOR REMODELED BEDROOM 167 SF FIRST FLOOR GARAGE DEMO 17 SF DRYWALL DEMO FOR SHEAR 39 SF DRYWALL DEMO FOR SHEAR 224 SF FIRST FLOOR CARPORT ADDITION 448 SF FIRST FLOOR CEILING REMODEL 137 SF FIRST FLOOR CEILING REMODEL *OPEN VOLUME AREA 129 SF SECOND FLOOR BEDROOM ADDITION 112 SF SECOND FLOOR LIVING ROOM ADD. 191 SF SECOND FLOOR DECK ADDITION 841 SF SECOND FLOOR REMODELED *OPEN VOLUME AREA AREA EXIBIT LEGEND EXISTING 2X4 WOOD STUD WALLS NEW 2X4 STUD WALLS ADDITION AREAS REMODEL AREAS 333 SF ROOF DECK ADDITION CLIENT: LICENCE STAMP: PROJECT TEAM: CONTACT: E-MAIL: E-MAIL: PRINCIPAL: PROJECT DIRECTOR: PROJECT DESIGNER: HOMER OATMAN hoatman@oatmanarchitects.com cadams@oatmanarchitects.com HOMER OATMAN CORY ADAMS BEHTASH AZAR THESE DRAWINGS ARE THE PROPERTY OF OATMAN ARCHITECTS AND SHALL NOT BE MODIFIED OR USED ON ANY OTHER PROJECT OR SITE WITHOUT WRITTEN PERMISSION. IT IS THE OWNER'S AND IT'S GENERAL CONTRACTOR'S RESPONSIBILITY, PRIOR TO OR DURING CONSTRUCTION, TO NOTIFY THE ARCHITECT IN WRITING OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND/ OR GENERAL NOTES OF WHICH A CONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND MEANS & METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE ARCHITECT PRIOR TO THE OWNER OR OWNER'S CONTRACTOR PROCEEDING WITH THE WORK. THE OWNER WILL BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT FOLLOWED. NOTE: THE ORIGINAL SIZE OF THIS DRAWING SHEET IS: 36"X48" Project Number: SUBMITTAL: REVISION: DATE DESCRIPTION 8/9/2018 3:26:06 PM A3.4 FLOOR AREA EXHIBITCLARIZIO REMODEL7401 SEASHORE, NEWPORT BEACH, CALOT 8, BLOCK N, SEASHORE COLONY TRACTPLAN CHECK # 0696-2018CDP SUBMITTALCHRIS CLARIZIO 2017005 03/23/18 BLDG. DEPT. SUBMITTAL 1 06/08/18 BLDG. DEPT. SUBMITTAL 2 06/28/18 BLDG. DEPT. SUBMITTAL 3 08/10/18 CDP SUBMITTAL 1/4" = 1'-0"1 FIRST FLOOR 1/4" = 1'-0"2 SECOND FLOOR REMODEL AREA T.O. SLAB 1ST FL. FIRST FLOOR KITCHEN REMODEL 89 SF FIRST FLOOR REMODELED BEDROOM 160 SF FIRST FLOOR GARAGE DEMO 167 SF DRYWALL DEMO FOR SHEAR 17 SF DRYWALL DEMO FOR SHEAR 39 SF FIRST FLOOR CEILING REMODEL 448 SF FIRST FLOOR CEILING REMODEL 137 SF 1,057 SF T.O. SHTG 2ND FL. SECOND FLOOR REMODELED 841 SF 841 SF GRAND TOTAL 1,898 SF EXISTING S.F. LIVING 2,200 EXISTING S.F. GARAGE 552 TOTAL EXISTING S.F.= 2752 TOTAL = 2,752 SF (EXISTING) + 241 SF (ADDITION) = 2,993 SF OPEN VOLUME AREA: REQUIRED = 1897.2 SF X 15% = 284.58 SF PROVODED = 224 SF (CARPORT) + 191 (DECK) = 415 SF ADDITION AREA T.O. SLAB 1ST FL. FIRST FLOOR CARPORT ADDITION 224 SF 224 SF T.O. SHTG 2ND FL. SECOND FLOOR BEDROOM ADDITION 129 SF SECOND FLOOR LIVING ROOM ADD.112 SF SECOND FLOOR DECK ADDITION 191 SF 432 SF T.O. SHTG 3RD FL. ROOF DECK ADDITION 333 SF 333 SF GRAND TOTAL 988 SF 1/4" = 1'-0"3 ROOF DECK CALCULATED TOGETHER CALCULATED TOGETHER NO. DATE DESCRIPTION A 06/08/18 PLAN CHECK CORRECTIONS 27 ROOF LEGEND DRAFTSTOP LINES 2" VTR COMBUSTION SUPPLY AND EXHAUST FROM FCU FCU LINE OF WALL BELOW FAU 22" X 30" MIN. ACCESS DOOR TO ATTIC O'HAGIN ATTIC VENTS AT CLAY ROOF TILES ROOF PLAN NOTESKEYNOTES 4 A5.0 1 A5.0 2 A5.0 3 A5.0 24'-0" 1 A0.6 2 A0.6 3 A0.6 4 A0.6 1 A6.0 1 A6.0 2 A6.0 2 A6.0 3 A6.0 3 A6.0 4 A6.0 4 A6.0 1 A0.3 2 A0.3 3 A0.3 4 A0.3 1/4" / 1'-0"1/4" / 1'-0"3'-0"5'-0"28'-8 1/2"1'-0"1'-3"9'-11"3'-6"10'-7"3'-6 1/16"EXISTING ROOF 3 D3.0 12 16 D1.0 12 D1.0 3'-9"3'-6" 1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12" 1/4" / 12" 1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"18'-1 1/2"18'-7"10'-3 1/2"12'-0"CLIENT: LICENCE STAMP: PROJECT TEAM: CONTACT: E-MAIL: E-MAIL: PRINCIPAL: PROJECT DIRECTOR: PROJECT DESIGNER: HOMER OATMAN hoatman@oatmanarchitects.com cadams@oatmanarchitects.com HOMER OATMAN CORY ADAMS BEHTASH AZAR THESE DRAWINGS ARE THE PROPERTY OF OATMAN ARCHITECTS AND SHALL NOT BE MODIFIED OR USED ON ANY OTHER PROJECT OR SITE WITHOUT WRITTEN PERMISSION. IT IS THE OWNER'S AND IT'S GENERAL CONTRACTOR'S RESPONSIBILITY, PRIOR TO OR DURING CONSTRUCTION, TO NOTIFY THE ARCHITECT IN WRITING OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND/ OR GENERAL NOTES OF WHICH A CONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND MEANS & METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE ARCHITECT PRIOR TO THE OWNER OR OWNER'S CONTRACTOR PROCEEDING WITH THE WORK. THE OWNER WILL BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT FOLLOWED. NOTE: THE ORIGINAL SIZE OF THIS DRAWING SHEET IS: 36"X48" Project Number: SUBMITTAL: REVISION: DATE DESCRIPTION 10/15/2018 2:07:03 PM A4.0 ROOF PLANCLARIZIO REMODEL7401 SEASHORE, NEWPORT BEACH, CALOT 8, BLOCK N, SEASHORE COLONY TRACTPLAN CHECK # 0696-2018CDP SUBMITTALCHRIS CLARIZIO 2017005 03/23/18 BLDG. DEPT. SUBMITTAL 1 06/08/18 BLDG. DEPT. SUBMITTAL 2 06/28/18 BLDG. DEPT. SUBMITTAL 3 08/10/18 CDP SUBMITTAL 1/4" = 1'-0"1 ROOF PLAN 12 CLASS "B" ROOFING ASSEMBLY REQUIRED PER I.C.C. ESR-2097: PLI-DEK ELASTOMERIC DECK SYSTEM TO BE INSTALLED PER MANUFACTURE AND ICC ESR-2097. 13 VENTING SHALL EXTEND ABOVE THE ROOF AND SHALL TERMINATE IN A VENT CAP. TERMINATION POINTS SHALL BE AT LEAST 4 FEET BELOW OR HORIZONTALLY FROM AND 1 FOOT ABOVE ANY OPENING INTO THE BUILDING, BE AT LEAST 3 FEET ABOVE ANY FORCED AIR INLET INTO THE BUILDING LOCATED WITHIN 10 FEET, AND SHALL BE 4 FEET AWAY FROM THE PROPERTY LINE, PER C.M.C. SECTIONS 802.6.2 AND 802.6.2.6. 14 ANY FORCED AIR UNITS LOCATED IN THE ATTIC MUST BE POSITIONED IN SUCH A MANNER THAT THE REQUIRED DISTANCE FROM THE VENT OUTLET TO THE TOP OF THE FLUE CAP IS WITHIN THE ATTIC, ALLOWING THE EXTERIOR HEIGHT OF THE FLUE CAP ABOVE THE FINISHED ROOFING TO BE THE MINIMUM ALLOWED BY CODE. 15 SOLAR REFLECTANCE AND THERMAL EMMITTANCE FOR NEW CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE COOL ROOF STANDARDS AND THE CALIF. ENERGY CODE, SECTION 150.0 16 EXPOSED ATTIC FLOOR INSULATION SHALL HAVE A CRITICAL RADIANT FLUX OF NOT LESS THAN 0.12 WATT PER SQUARE CENTIMETER PER ASTM E 970. 17 FIREBLOCKING IS REQUIRED IN CONCEALED SPACES 10'-0" O.C. HORIZONTAL, VERTICALLY AT THE CEILING AND FLOOR LEVELS, CONNECTIONS BETWEEN HORIZONTAL AND VERTICAL SPACES, CONCEALED SPACES BETWEEN STAIR AND LANDINGS, OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES, WIRES, CHIMNEYS AND FIREPLACES PER C.R.C. R302.11. 18 DO NOT SCALE DRAWINGS. 1 REFER TO GENERAL NOTES FOR ADDITIONAL REQUIRED INFORMATION. 2 ALL RIDGE ELEVATIONS ARE TO TOP OF FINISH MATERIAL. 3 ALL FLASHING, SHEET METAL, VENT STACKS AND PIPES SHALL BE COPPER OR PAINTED TO MATCH ADJACENT BUILDING SURFACE. 4 PROVIDE COPPER FLASHING AT ALL VALLEYS AND ROOF TO WALL CONDITIONS. REFER TO DETAILS. 5 ALL PLUMBING AND EQUIPMENT VENTS MUST BE CONSOLIDATED AND LOCATED IN AREAS THAT MINIMIZE THEIR VISIBILITY. VENTS MUST BE AS LOW IN HEIGHT AS ALLOWED BY CODE AND SATISFY THE REQUIREMENTS OF THE DESIGN GUIDELINES. 6 IN "CALIFORNIA" DOUBLE FRAMING AREAS PROVIDE OPENINGS INTO MAIN ATTIC SPACE FOR ADEQUATE VENTILATION, PER C.R.C SECTION R806. 7 IF "CALIFORNIA" DOUBLE FRAME AREA EXCEEDS 30 SQUARE FEET AND HAS A 30" MIN. CLEAR HEADROOM, PROVIDE A 22"X30" MIN. ACCESS THROUGH MAIN ROOF SHEATHING, PER C.R.C SECTION R807. VERIFY OPENINGS IN ROOF SHEATHING WITH STRUCTURAL ENGINEER. 8 AT ALL AREAS WITHIN THE ROOF ATTIC THAT EXCEED 30 SQUARE FEET AND WITH 30" MIN. CLEAR HEADROOM, PROVIDE A 22"X30" MIN. ATTIC ACCESS TO THOSE AREAS, PER C.R.C SECTION R807. ATTICS WITH APPLIANCES OR F.A.U UNITS INSTALLED IN THEM, PROVIDE A 30"x30" MIN. ATTIC ACCESS, (PROVIDED F.A.U. MAY PASS THROUGH) WITH 30" MIN. CLEAR HEADROOM. PROVIDE WEATHER STRIPS AT PANEL TO PREVENT BACK DRAFT. 9 THE CONTRACTOR SHALL INSTALL DRAFT STOPPING TO SUBDIVIDE ATTIC SPACES AND CONCEALED ROOF SPACES, SUCH THAT ANY HORIZONTAL AREA DOES NOT EXCEED 1,000 S.F., OR PER MIN. REQUIREMENTS OF C.R.C SECTION 302.12.DRAFTSTOP MATERIALS TO BE NO LESS THAN1/2" GYP. BD. OR 3/8" PLYWOOD INSTALLED PARALLEL TO FLOOR AND ROOF FRAMING. 10 PRIOR TO THE RELEASE OF THE ROOF SHEATHING INSPECTION, THE APPLICANT SHALL SUBMIT CERTIFICATION, BY A SURVEY OR OTHER APPROPRIATE METHOD, THAT THE HEIGHT OF THE STRUCTURES IS IN COMPLIANCE WITH THE ADOPTED APPROVAL RESOLUTION, AND THE HEIGHT LIMITATIONS OF THE APPLICABLE ZONING DISTRICT. 11 PRIOR TO THE ISSUANCE OF A CERTIFICATE OF USE AND OCCUPANCY, WRITTEN CERTIFICATION BY A CALIFORNIA REGISTERED ENGINEER THAT THE ROOF SLOPE IS IN CONFORMANCE WITH THE APPROVED PLANS SHALL BE SUBMITTED TO THE CITY BUILDING INSPECTOR. NO. DATE DESCRIPTION A 06/08/18 PLAN CHECK CORRECTIONS 2 10/15/18 A/C RELOCATION REV. 2 28 ELEVATION LEGEND O'HAGIN ATTIC VENTS AT CLAY ROOF TILES A DETAIL CALLOUT KEYNOTE FLOOR LEVEL MAX BUILDING HEIGHT / NATURAL GRADE A101 1 SIM ELEVATION NOTES 1. DO NOT SCALE DRAWINGS. 2. REFER TO GENERAL NOTES FOR ADDITIONAL REQUIRED INFORMATION. 3. ALL RIDGE ELEVATIONS ARE TO TOP OF FINISH MATERIAL. 4. CONTRACTOR TO PROVIDE MOCK-UP OF ROOF TILES, EXTERIOR PLASTER FINISH COLOR AND TEXTURE, HEAVY TIMBER WOOD STAIN COLOR, GUTTER AND DOWN SPOUT PAINT COLOR, AND EXTERIOR WINDOW AND DOOR FRAME FINISH FOR ARCHITECT'S APPROVAL PRIOR TO CONSTRUCTION. 5. BUILDING ADDRESS SHALL BE PROVIDED ON THE BUILDING IN SUCH A POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET AND TO BE A MINIMUM OF 4" HIGH X 1" WIDE NONCOMBUSTIBLE, CONTRASTING MATERIALS OR PER LOCAL CITY AND FIRE DEPARTMENT REQUIREMENTS. 6. REFER TO LANDSCAPE DRAWINGS FOR THE HARDSCAPE PAVING MATERIAL PLAN, SOFTSCAPE PLANTING PLAN, IRRIGATION PLAN, GARDEN WALLS, EXTERIOR GUARDRAILS AND HANDRAILS, FENCE(S), GATES, SWIMMING POOL AND SPA PLAN. . .ETC. EXTERIOR ELEVATION AND SECTION KEYNOTES T.O. SLAB 1ST FL. 13'-9 77/128" T.O. SHTG 2ND FL. 22'-7 77/128" T.O. PLT. 2ND FL. 30'-7 77/128" T.O. PLT. 1ST FL. 21'-9 77/128" T.O. SHTG 3RD FL. 31'-6 77/128"TOP OF EXISTING ROOF18'-9 3/8"8'-0"10"8'-0"6 9/16"EST. GRADE 12.89' EXISTING ROOF 31.67'EXISING BUILDING HEIGHT ABOVE ESTABLISHED GRADE: 31.97' - 12.89' = 18.78' HEIGHT INCREASE: 35.24' - 31.67' = 3.57' 3.57'/ 31.67 = 11.27% T.O. RAIL 35.24'42" MIN.22'-4 3/16"T.O. SLAB 1ST FL. 13'-9 77/128" T.O. SHTG 2ND FL. 22'-7 77/128" T.O. PLT. 2ND FL. 30'-7 77/128" T.O. PLT. 1ST FL. 21'-9 77/128" T.O. SHTG 3RD FL. 31'-6 77/128"44" MAX44" MAX8'-0"10"8'-0"17'-10 7/16"6 9/16"42" MIN.EST. GRADE 12.89' EXISTING ROOF 31.67' TO REMAIN OPEN T.O. RAIL 35.24'42" MIN.22'-4 3/16"T.O. SLAB 1ST FL. 13'-9 77/128" T.O. SHTG 2ND FL. 22'-7 77/128" T.O. PLT. 2ND FL. 30'-7 77/128" T.O. PLT. 1ST FL. 21'-9 77/128" T.O. SHTG 3RD FL. 31'-6 77/128"8'-0"10"8'-0"11"8"42" MIN.TO REMAIN OPEN42" MIN.22'-4 3/16"EST. GRADE 12.89' T.O. RAIL 35.24' T.O. SLAB 1ST FL. 13'-9 77/128" T.O. SHTG 2ND FL. 22'-7 77/128" T.O. PLT. 2ND FL. 30'-7 77/128" T.O. PLT. 1ST FL. 21'-9 77/128" T.O. SHTG 3RD FL. 31'-6 77/128"8"11"8'-0"10"8'-0"44" MAX44" MAX42" MIN.EST. GRADE 12.89'22'-4 3/16"EXISTING ROOF 31.67' CLIENT: LICENCE STAMP: PROJECT TEAM: CONTACT: E-MAIL: E-MAIL: PRINCIPAL: PROJECT DIRECTOR: PROJECT DESIGNER: HOMER OATMAN hoatman@oatmanarchitects.com cadams@oatmanarchitects.com HOMER OATMAN CORY ADAMS BEHTASH AZAR THESE DRAWINGS ARE THE PROPERTY OF OATMAN ARCHITECTS AND SHALL NOT BE MODIFIED OR USED ON ANY OTHER PROJECT OR SITE WITHOUT WRITTEN PERMISSION. IT IS THE OWNER'S AND IT'S GENERAL CONTRACTOR'S RESPONSIBILITY, PRIOR TO OR DURING CONSTRUCTION, TO NOTIFY THE ARCHITECT IN WRITING OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND/ OR GENERAL NOTES OF WHICH A CONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND MEANS & METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE ARCHITECT PRIOR TO THE OWNER OR OWNER'S CONTRACTOR PROCEEDING WITH THE WORK. THE OWNER WILL BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT FOLLOWED. NOTE: THE ORIGINAL SIZE OF THIS DRAWING SHEET IS: 36"X48" Project Number: SUBMITTAL: REVISION: DATE DESCRIPTION 10/15/2018 2:07:16 PM A5.0 EXTERIOR ELEVATIONSCLARIZIO REMODEL7401 SEASHORE, NEWPORT BEACH, CALOT 8, BLOCK N, SEASHORE COLONY TRACTPLAN CHECK # 0696-2018CDP SUBMITTALCHRIS CLARIZIO 2017005 03/23/18 BLDG. DEPT. SUBMITTAL 1 06/08/18 BLDG. DEPT. SUBMITTAL 2 06/28/18 BLDG. DEPT. SUBMITTAL 3 08/10/18 CDP SUBMITTAL 1/4" = 1'-0"1 FRONT 1/4" = 1'-0"2 LEFT 1/4" = 1'-0"3 REAR 1/4" = 1'-0"4 RIGHT NO. DATE DESCRIPTION B 06/28/18 PLAN CHECK CORRECTIONS C 08/03/18 ROOF DECK RAILING & STAIR 2 10/15/18 A/C RELOCATION REV. 2 2 29 SECTION LEGEND PROPERTY LINE SETBACK LINE NATURAL GRADE LINE MAX. HEIGHT LINE EXTERIOR 2 X 6 STUD WALL, U.N.O. INTERIOR 2 X 6 STUD WALL, U.N.O. FOUNDTION SLAB PER STRUCTURAL DRAWINGS WOOD JOIST FLOOR COMPOUND CEILING ROOF 1-HR FIRE SEPORATION SECTION NOTES T.O. SLAB 1ST FL. 13'-9 77/128" T.O. SHTG 2ND FL. 22'-7 77/128" T.O. PLT. 2ND FL. 30'-7 77/128" T.O. PLT. 1ST FL. 21'-9 77/128" T.O. SHTG 3RD FL. 31'-6 77/128" BED 5 KITCHEN LAUNDRY BATH 3 BATH2 BED 2 EXISTING GARAGE EXISTING GARAGE BED 1 BATH BED 3 EXTERIOR PARKING 4 D1.0 3 D1.0 3 D1.0 3 D1.0 BATH 4 1 D1.0 2 D1.0 6 D1.0 7'-0 1/8"8'-2"11"8'-0"10"8'-0"T.O. SLAB 1ST FL. 13'-9 77/128" T.O. SHTG 2ND FL. 22'-7 77/128" T.O. PLT. 2ND FL. 30'-7 77/128" T.O. PLT. 1ST FL. 21'-9 77/128" T.O. SHTG 3RD FL. 31'-6 77/128" DECK LIVING ROOM BED 4 BED 3 BATH 1 BED 3 EXTERIOR PARKING EXISTING GARAGE EXISTING GARAGE BED 2 KITCHEN 8'-2"7'-0 1/8"4 D1.0 3 D1.0 4 D1.0 3 D1.0 3 D1.0 6 D1.0 5 D1.0 D2.0 11 11"8'-0"10"8'-0"6 9/16"T.O. SLAB 1ST FL. 13'-9 77/128" T.O. SHTG 2ND FL. 22'-7 77/128" T.O. PLT. 2ND FL. 30'-7 77/128" T.O. PLT. 1ST FL. 21'-9 77/128" T.O. SHTG 3RD FL. 31'-6 77/128"8'-2"7'-0 1/8"5 D1.0 6 D1.0 2 D1.0D3.0 3 11"8'-0"10"8'-0"7'-0"D3.0 3 T.O. SLAB 1ST FL. 13'-9 77/128" T.O. SHTG 2ND FL. 22'-7 77/128" T.O. PLT. 2ND FL. 30'-7 77/128" T.O. PLT. 1ST FL. 21'-9 77/128" BED 2 BED 3 BED 3 KITCHEN 8'-0"10"8'-0"4 D1.0 CLIENT: LICENCE STAMP: PROJECT TEAM: CONTACT: E-MAIL: E-MAIL: PRINCIPAL: PROJECT DIRECTOR: PROJECT DESIGNER: HOMER OATMAN hoatman@oatmanarchitects.com cadams@oatmanarchitects.com HOMER OATMAN CORY ADAMS BEHTASH AZAR THESE DRAWINGS ARE THE PROPERTY OF OATMAN ARCHITECTS AND SHALL NOT BE MODIFIED OR USED ON ANY OTHER PROJECT OR SITE WITHOUT WRITTEN PERMISSION. IT IS THE OWNER'S AND IT'S GENERAL CONTRACTOR'S RESPONSIBILITY, PRIOR TO OR DURING CONSTRUCTION, TO NOTIFY THE ARCHITECT IN WRITING OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND/ OR GENERAL NOTES OF WHICH A CONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND MEANS & METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE ARCHITECT PRIOR TO THE OWNER OR OWNER'S CONTRACTOR PROCEEDING WITH THE WORK. THE OWNER WILL BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT FOLLOWED. NOTE: THE ORIGINAL SIZE OF THIS DRAWING SHEET IS: 36"X48" Project Number: SUBMITTAL: REVISION: DATE DESCRIPTION 8/9/2018 3:26:39 PM A6.0 BUILDING SECTIONSCLARIZIO REMODEL7401 SEASHORE, NEWPORT BEACH, CALOT 8, BLOCK N, SEASHORE COLONY TRACTPLAN CHECK # 0696-2018CDP SUBMITTALCHRIS CLARIZIO 2017005 03/23/18 BLDG. DEPT. SUBMITTAL 1 06/08/18 BLDG. DEPT. SUBMITTAL 2 06/28/18 BLDG. DEPT. SUBMITTAL 3 08/10/18 CDP SUBMITTAL 1/4" = 1'-0"1 Section 9 1/4" = 1'-0"2 Section 1 1/4" = 1'-0"3 Section 10 1/4" = 1'-0"4 Section 11 NO. DATE DESCRIPTION A 06/08/18 PLAN CHECK CORRECTIONS 30