Loading...
HomeMy WebLinkAbout04_McLain Residence Coastal Development Permit_PA2018-219SUBJECT: CITY OF NEWPORT BEACH ZONING ADMINISTRATOR STAFF REPORT SITE LOCATION: APPLICANT: OWNER: PLANNER: February 14, 2019 Agenda Item No. 4 McLain Residence Coastal Development Permit (PA2018-219) Coastal Development Permit No. CD2018-091 2168 East Ocean Front Graham Architecture Helle Skov McLain Chelsea Crager, Associate Planner 949-644-3227, ccrager@newportbeachca.gov LAND USE AND ZONING • General Plan: RS -D (Single -Unit Residential Detached) • Zoning District : R-1 (Single -Unit Residential) • Coastal Land Use Category: RSD -C (Single -Unit Residential Detached — (10.0-19.9 DU/AC)) • Coastal Zoning District: R-1 (Single -Unit Residential) PROJECT SUMMARY A coastal development permit (CDP) for the demolition of an existing single-family dwelling and the construction of a new, 3,735 -square -foot, two-story single-family dwelling with a 447 -square -foot, two -car garage. The development also includes hardscape, drainage, accessory structures, and landscaping. The proposed development complies with all applicable development standards including height, setbacks and floor area limits. No deviations are requested. RECOMMENDATION 1) Conduct a public hearing; 2) Find this project exempt from the California Environmental Quality Act (CEQA) pursuant to Section 15303 under Class 3 (New Construction or Conversion of Small Structures), because it has no potential to have a significant effect on the environment; and 3) Adopt Draft Zoning Administrator Resolution No. — approving Coastal Development Permit No. CD2018-091 (Attachment No. ZA 1). 03/13/2018 McLain Residence (PA2018-219) Zoning Administrator, February 14, 2019 Page 2 Land Use and Development Standards • The subject property is located in the R-1 Coastal Zoning District, which allows a maximum of one residential dwelling unit on a single legal lot, and is consistent with the City's Coastal Land Use Plan, General Plan, and Zoning Code. A coastal development permit is required and the property is not eligible for a waiver for de minimis development because the property is located in the Coastal Commission Appeal Area. • The property consists of one legal lot developed with a single-family residence. The neighborhood is predominantly developed with two- and three-story single-family residences. The proposed design, bulk, and scale of the development is consistent with the existing neighborhood pattern of development and expected future development because the project complies with all applicable development standards. • The proposed single-family dwelling and accessory structures conform to all applicable development standards, including floor area limit, setbacks, height, and off-street parking as evidenced by the project plans and illustrated in Table 1 below. Hazards • The project site fronts the Pacific Ocean but is separated from the shoreline by a wide sandy beach. The site is not protected by a bulkhead or other protective device. The finish floor elevation of the proposed dwelling is 14.0 feet North American Vertical Datum of 1988 (NAVD88), which exceeds the minimum 9 feet (NAVD88) elevation standard. Impacts from sea level rise is not anticipated at this time for the 75 -year economic life of the proposed improvements. Tmplt 04/03/18 Table 1 — Development rdLEff Development Standard Standard Proposed Setbacks min. Front Beach 10 feet 10 feet Rear(Alley) 0 feet 10 feet Sides 4 feet 4 feet Allowable Floor Area 6,108 square feet 4,182 square feet Allowable 3' Floor Area 458 square feet 0 square feet Open Volume Area 458 square feet 1,000 square feet Parkin 2 -car garage 2 -car garage Height 24 -foot flat roof 29 -foot sloped roof 24 -foot flat roof 29 -foot sloped roof Hazards • The project site fronts the Pacific Ocean but is separated from the shoreline by a wide sandy beach. The site is not protected by a bulkhead or other protective device. The finish floor elevation of the proposed dwelling is 14.0 feet North American Vertical Datum of 1988 (NAVD88), which exceeds the minimum 9 feet (NAVD88) elevation standard. Impacts from sea level rise is not anticipated at this time for the 75 -year economic life of the proposed improvements. Tmplt 04/03/18 McLain Residence (PA2018-219) Zoning Administrator, February 14, 2019 Page 3 • A project -specific Coastal Hazards Report and Sea Level Rise Analysis was prepared by GeoSoils, Inc., dated June 26, 2018. The report concludes that the highest high tide elevation (currently 7.5 feet NAVD88) will not exceed the proposed finished floor elevation of 14.0 feet NAVD88 using the low-rise aversion projected sea level rise (2.9 -foot increase) over the 75 -year design life of the structure, based on estimates for sea level rise provided by the State of California Sea -Level Rise Guidance 2018. No protective devices will be necessary to protect the proposed development from any existing or anticipated future coastal hazards and that the proposed project will be safe from coastal hazards for the next 75 years or more. • The property is located in an area known for the potential of seismic activity and liquefaction. All projects are required to comply with the California Building Code (CBC) and Building Division standards and policies. Geotechnical investigations specifically addressing liquefaction are required to be reviewed and approved prior to the issuance of a building permit. Permit issuance is also contingent on the inclusion of design mitigation identified in the investigations. Construction plans are reviewed for compliance with approved investigations and CBC prior to building permit issuance. • Pursuant to Newport Beach Municipal Code (NBMC) Section 21.30.030(C)(3)(i)(iv), the property owner will be required to enter into an agreement with the City waiving any potential right to protection to address situations in the future in which the development is threatened with damage or destruction by coastal hazards (e.g., waves, erosion, and sea level rise). The property owner will also be required to acknowledge any hazards present at the site and unconditionally waive any claim to damage or liability against the decision authority, consistent with NBMC Section 21.30.015(D)(3)(c). Both requirements are included as conditions of approval that will need to be satisfied prior to the issuance of building permits for construction. Water Quality • The project design addresses water quality with a construction erosion control plan and a post construction drainage system that includes drainage and percolation features designed to retain dry weather run-off and minor rain event run-off on-site. Any water not retained on-site is directed to the City's storm drain system. • Pursuant to Municipal Code Section 21.35.050 (Water Quality and Hydrology Plan), due to the proximity of the development to the shoreline and the development containing more than 75 percent of impervious surface area, a preliminary Water Quality and Hydrology Plan (WQHP) has been provided and will undergo a final review during building permit plan check. The WQHP was prepared for the project by Toal Engineering, Inc. on December 13, 2018. The WQHP includes a polluted Tmplt 04/03/18 McLain Residence (PA2018-219) Zoning Administrator, February 14, 2019 Page 4 runoff and hydrologic site characterization, a sizing standard for Best Management Practices (BMPs), use of a low impact development (LID) approach to retain the design storm runoff volume on site, and documentation of the expected effectiveness of the proposed BMPs. Construction plans will be reviewed for compliance with the approved WQHP prior to building permit issuance. Public Access • The project site is located between the nearest public road and the sea or shoreline; however, the project will not affect the public's ability to gain access to use and/or view the coast and nearby recreational facilities. The existing residential development neither provides nor inhibits public coastal access. Implementation Plan Section 21.30A.040 (Determination of Public Access/Recreation Impacts) requires that the provision of public access bear a reasonable relationship between the requirement and the project's impact and be proportional to the impact. In this case, the project replaces an existing single-family residence with a new single-family residence. Therefore, the project does not involve a change in land use, density or intensity that will result in increased demand on public access and recreation opportunities. • The project is designed and sited so as not to block or impede existing public access opportunities and development will occur within the confines of private property. Existing coastal access conditions will not be affected. Coastal access is currently provided and will continue to be provided by street ends throughout the Balboa Peninsula with access to the beach and water and at West Jetty View Park approximately 50 feet east of the subject property. • The project site is not located adjacent to a coastal view road. However, it is located approximately 50 feet west of West Jetty View Park, a public viewpoint as identified in the Coastal Land Use Plan. The project site is also located adjacent to a public beach. The views from West Jetty View Park are primarily toward the Newport Harbor entrance and the ocean and are not toward the project site. The project site may be located within the viewshed of distant public viewing areas. However, the project will replace an existing single-family residence with a new single-family residence that complies with all applicable Local Coastal Program (LCP) development standards and maintains a building envelope consistent with the existing and anticipated neighborhood pattern of development. Therefore, the project does not have the potential to degrade the visual quality of the Coastal Zone or result in significant adverse impacts to public views. ENVIRONMENTAL REVIEW This project is exempt from the California Environmental Quality Act (CEQA) pursuant to Section 15303 under Class 3 (New Construction or Conversion of Small Structures) of Tmplt 04/03/18 J McLain Residence (PA2018-219) Zoning Administrator, February 14, 2019 Page 5 the CEQA Guidelines, California Code of Regulations, Title 14, Chapter 3, because it has no potential to have a significant effect on the environment. Class 3 exempts the construction and location of limited numbers of new, small facilities or structures including one single-family dwelling in a residential zone. The proposed project consists of the demolition of an existing single-family dwelling and the construction of a new 4,182 -square -foot single-family dwelling. PUBLIC NOTICE Notice of this public hearing was published in the Daily Pilot, mailed to all owners and residential occupants of property within 300 feet of the boundaries of the site (excluding intervening rights-of-way and waterways), including the applicant, and posted on the subject property at least 10 days before the scheduled hearing, consistent with the provisions of the Municipal Code. Additionally, the item appeared on the agenda for this meeting, which was posted at City Hall and on the City website. APPEAL PERIOD: This action shall become final and effective 14 days following the date the Resolution is adopted unless within such time an appeal or call for review is filed with the Community Development Director in accordance with the provisions of Title 21 (Local Coastal Implementation Plan) of the Newport Beach Municipal Code. Final action taken by the City may be appealed to the Coastal Commission in compliance with Section 21.64.035 of the City's certified LCP and Title 14 California Code of Regulations, Sections 13111 through 13120, and Section 30603 of the Coastal Act. For additional information on filing an appeal, contact the Planning Division at 949-644-3200. Prepared by: Chelsea Crager Associate Planner GBR/M Attachments: ZA 1 Draft Resolution ZA 2 Vicinity Map ZA 3 Project Plans Tmplt 04/03/18 Attachment No. ZA 1 Draft Resolution 03/13/2018 RESOLUTION NO. ZA2019-### A RESOLUTION OF THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH APPROVING COASTAL DEVELOPMENT PERMIT NO. CD2018-091 TO DEMOLISH AN EXISTING SINGLE-FAMILY RESIDENCE AND CONSTRUCT A NEW TWO-STORY, SINGLE-FAMILY RESIDENCE AND ATTACHED TWO -CAR GARAGE AT 2168 EAST OCEAN FRONT (PA2018-219) THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH HEREBY FINDS AS FOLLOWS: SECTION 1. STATEMENT OF FACTS. 1. An application was filed by Graham Architecture ("Applicant'), on behalf of Helle Skov McLain ("Owner"), with respect to property located at 2168 East Ocean Front, requesting approval of a coastal development permit. 2. The property is legally described as Lot 18, Block E, of Tract 518 in Newport Beach. 3. The applicant proposed a coastal development permit for the demolition of an existing single-family dwelling and the construction of a new, 3,735 -square -foot, two-story single- family dwelling with a 447 -square -foot, two -car garage. The development also includes hardscape, drainage, accessory structures, and landscaping. The proposed development complies with all applicable development standards including height, setbacks and floor area limits. No deviations are requested. 4. The subject property is designated RS -D (Single -Unit Residential Detached) by the General Plan Land Use Element and is located within the R-1 (Single -Unit Residential) Zoning District. 5. The subject property is located within the coastal zone. The Coastal Land Use Plan category is RSD -C (Single -Unit Residential Detached — 10.0-19.9 DU/AC) and the property is located within the R-1 (Single -Unit Residential) Coastal Zone District. 6. A public hearing was held on February 14, 2019, in the Corona del Mar Conference Room (Bay E -1st Floor) at 100 Civic Center Drive, Newport Beach. A notice of time, place and purpose of the hearing was given in accordance with the Newport Beach Municipal Code. Evidence, both written and oral, was presented to and considered by the Zoning Administrator at this hearing. SECTION 2. CALIFORNIA ENVIRONMENTAL QUALITY ACT DETERMINATION. 1. This project is categorically exempt pursuant to Title 14 of the California Code of Regulations Section 15303, Article 19 of Chapter 3, Guidelines for Implementation of the California Environmental Quality Act (CEQA) under Class 3 (New Construction or 7 Zoning Administrator Resolution No. ZA2019-### Paqe 2 of 9 Conversion of Small Structures), because it has no potential to have a significant effect on the environment. 2. Class 3 exempts the construction and location of limited numbers of new, small facilities or structures including one residential duplex in a residential zone. The proposed project consists of the demolition of a single-family residence and the construction of a new two- story, 3,735 -square -foot, single-family residence with an attached 447 -square -foot two - car garage in the R-1 Zoning District. SECTION 3. REQUIRED FINDINGS. In accordance with Section 21.52.015 (Coastal Development Permits, Findings and Decision) of the Newport Beach Municipal Code (NBMC), the following findings and facts in support of such findings are set forth: Finding: A. Conforms to all applicable sections of the certified Local Coastal Program. Facts in Support of Finding: The proposed development complies with applicable residential development standards including, but not limited to, floor area limitation, setbacks, height, and parking. a. The maximum floor area limitation is 6,108 square feet and the proposed gross floor area is 4,182 square feet. b. The proposed development will provide the minimum required setbacks, which are ten feet along the front property line abutting the beach, four feet along each side property line, and zero feet along the rear property line abutting the alley. The highest flat roof is no more than 24 feet, measured from the established grade level of 14.14 feet North American Vertical Datum of 1988 (NAVD88) and the highest roof ridge is no more than 29 feet, measured from the established grade, which complies with the maximum height limitation. d. The project includes enclosed garage parking for two vehicles, which complies with the minimum parking requirement for single-family residences with less than 4,000 square feet of livable floor area. 2. The neighborhood is predominantly developed with two- and three-story single-family residences. The proposed design, bulk, and scale of the development will be consistent with the existing neighborhood pattern of development and expected future development. 3. Pursuant to NBMC Section 21.30.030(C)(3)(i)(iv), the property owner will be required to enter into an agreement with the City waiving any potential right to protection to address I Zoning Administrator Resolution No. ZA2019-### Paqe 3 of 9 situations in the future in which the development is threatened with damage or destruction by coastal hazards (e.g., waves, erosion, and sea level rise). The property owner will also be required to acknowledge any hazards present at the site and unconditionally waive any claim to damage or liability against the decision authority, consistent with NBMC Section 21.30.015(D)(3)(c). Both requirements are included as conditions of approval that will need to be satisfied prior to the issuance of building permits for construction. 4. The finished floor elevation of the first floor of the proposed structure is 14.0 feet (NAVD88), which complies with the minimum 9.0 -foot (NAVD88) elevation standard for new structures. A project -specific Coastal Hazards Report and Sea Level Rise Analysis was prepared by GeoSoils, Inc., dated June 26, 2018. The report concludes that the highest high tide elevation (currently 7.5 feet NAVD88) will not exceed the proposed finished floor elevation of 14.0 feet NAVD88 using the low-rise aversion projected sea level rise (2.9 -foot increase) over the 75 -year design life of the structure based on estimates for sea level rise provided by the State of California Sea -Level Rise Guidance 2018. 5. Pursuant to NBMC Section 21.35.050 (Water Quality and Hydrology Plan), because of the project site's proximity to coastal waters, a Water Quality and Hydrology Plan (WQHP) was prepared by Toal Engineering, Inc. dated December 13, 2018. The WQHP includes a polluted runoff and hydrologic site characterization, a sizing standard for Best Management Practices (BMPs), use of a low -impact development design approach to retain the storm runoff volume on site, and documentation of the expected effectiveness of the proposed BMPs. Construction plans will be reviewed for compliance with the approved WQHP prior to building permit issuance. 6. The property is located in an area known for the potential of seismic activity and liquefaction. All projects are required to comply with the California Building Code (CBC) and Building Division standards and policies. Geotechnical investigations specifically addressing liquefaction are required to be reviewed and approved prior to the issuance of building permits. Permit issuance is also contingent on the inclusion of design mitigation identified in the investigations. Construction plans are reviewed for compliance with approved investigations and the CBC prior to building permit issuance. 7. A post -construction drainage system will be installed that includes drainage and percolation features designed to retain dry weather and minor rain runoff on-site to ensure the project does not impact water quality. Any water not retained on-site is directed to the City's storm drain system. 8. The project design addresses water quality with a construction erosion control plan that outlines temporary BMPs to be implemented during construction to minimize erosion and sedimentation, and to minimize pollution of runoff derived by construction chemicals and materials. No water quality impacts to coastal waters are anticipated based upon the location and elevation of the property. . 9. New landscaping will be verified for compliance with NBMC Section 21.30.075. A condition of approval is included that requires drought -tolerant, and prohibits invasive species. Prior 0 Zoning Administrator Resolution No. ZA2019-### Paqe 4 of 9 to issuance of the building permits, the final landscape plans will be reviewed to verify invasive species are not planted. 10. The property is not located near coastal view roads and is located near West Jetty View Park, a public viewpoint. Views from this viewpoint are generally toward the Newport Harbor entrance and ocean; therefore, the project will not negatively impact public coastal views. Finding: B. Conforms with the public access and public recreation policies of Chapter 3 of the Coastal Act if the project is located between the nearest public road and the sea or shoreline of any body of water located within the coastal zone. Facts in Support of Finding: The project site is located between the nearest public road and the sea or shoreline; however, the project will not affect the public's ability to gain access to, use, and/or view the coast and nearby recreational facilities. The existing residential development neither provides nor inhibits public coastal access. Implementation Plan Section 21.30A.040 (Determination of Public Access/Recreation Impacts) requires that the provision of public access bear a reasonable relationship between the requirement and the project's impact and be proportional to the impact. In this case, the project replaces an existing single-family residence with a new single-family residence. Therefore, the project does not involve a change in land use, density or intensity that will result in increased demand on public access and recreation opportunities. 2. The project is designed and sited so as not to block or impede existing public access opportunities and development will occur within the confines of private property. Existing coastal access conditions will not be affected. Coastal access is currently provided and will continue to be provided by street ends throughout the Balboa Peninsula with access to the beach and water and at West Jetty View Park, approximately 50 feet east of the subject property. 3. The project site is not located adjacent to a coastal view road. However, it is located approximately 50 feet west of West Jetty View Park, a public viewpoint as identified in the Coastal Land Use Plan. The project site is also located adjacent to a public beach. The views from West Jetty View Park are primarily toward the Newport Harbor entrance and the ocean and are not toward the project site. The project site may be located within the viewshed of distant public viewing areas. However, the project will replace an existing single-family residence with a new single-family residence that complies with all applicable Local Coastal Program (LCP) development standards and maintains a building envelope consistent with the existing and anticipated neighborhood pattern of development. Therefore, the project does not have the potential to degrade the visual quality of the Coastal Zone or result in significant adverse impacts to public views. SECTION 4. DECISION. 10 Zoning Administrator Resolution No. ZA2019-### Paqe 5 of 9 NOW, THEREFORE, BE IT RESOLVED: 1. The Zoning Administrator of the City of Newport Beach hereby approves Coastal Development Permit No. CD2018-091, subject to the conditions set forth in Exhibit "A," which is attached hereto and incorporated by reference. 2. This action shall become final and effective 14 days following the date this Resolution was adopted unless within such time an appeal or call for review is filed with the Community Development Director in accordance with the provisions of Title 21 Local Coastal Implementation Plan, of the Newport Beach Municipal Code. Final action taken by the City may be appealed to the Coastal Commission in compliance with Section 21.64.035 of the City's certified LCP and Title 14 California Code of Regulations, Sections 13111 through 13120, and Section 30603 of the Coastal Act. PASSED, APPROVED, AND ADOPTED THIS 14TH DAY OF FEBRUARY, 2019 Patrick J. Alford, Zoning Administrator 11 Zoning Administrator Resolution No. ZA2019-##I# Paqe 6 of 9 EXHIBIT "A" CONDITIONS OF APPROVAL 1. The development shall be in substantial conformance with the approved site plan, floor plans and building elevations, stamped and dated with the date of this approval (except as modified by applicable conditions of approval). 2. Revisions to the approved plans may require an amendment to this Coastal Development Permit or the processing of a new coastal development permit. 3. Coastal Development Permit No. CD2018-091 shall expire unless exercised within 24 months from the date of approval as specified in Section 21.54.060 (Time Limits and Extensions) of the Newport Beach Municipal Code, unless an extension is otherwise granted 4. Prior to the issuance of a building permit, an agreement in a form approved by the City Attorney between the property owner and the City shall be executed and recorded waiving rights to the construction of future shoreline protection devices including the repair and maintenance, enhancement, reinforcement, or any other activity affecting the bulkhead, that results in any encroachment seaward of the authorized footprint of the bulkhead or other shoreline protective device. The agreement shall be binding against the property owners and successors and assigns. 5. Prior to the issuance of a building permit, the property owner shall submit a notarized signed letter acknowledging all hazards present at the site, assuming the risk of injury or damage from such hazards, unconditionally waiving any claims of damage against the City from such hazards, and to indemnify and hold harmless City, its City Council, its boards and commissions, officials, officers, employees, and agents from and against any and all claims, demands, obligations, damages, actions, causes of action, suits, losses, judgments, fines, penalties, liabilities, costs and expenses (including without limitation, attorney's fees, disbursements and court costs) of every kind and nature whatsoeverwhich may arise from or in any manner relate (directly or indirectly) to City's approval of development. 6. The project is subject to all applicable City ordinances, policies, and standards, unless specifically waived or modified by the conditions of approval. 7. The applicant shall comply with all federal, state, and local laws. Material violation of any of those laws in connection with the use may be cause for revocation of this coastal development permit. 8. This Coastal Development Permit may be modified or revoked by the Zoning Administrator if determined that the proposed uses or conditions under which it is being operated or maintained is detrimental to the public health, welfare or materially injurious to property or improvements in the vicinity or if the property is operated or maintained so as to constitute a public nuisance. 12 Zoning Administrator Resolution No. ZA2019-### Paqe 7 of 9 9. This approval does not authorize any new or existing improvements (including landscaping) on State tidelands, public beaches, or the public right-of-way. 10. This Coastal Development Permit does not authorize any development seaward of the private property. 11. Best Management Practices and Good Housekeeping Practices shall be implemented prior to and throughout the duration of construction activity as designated in the Construction Pollution Prevention Plan. 12. Prior to issuance of the building permits, a copy of the Resolution, including conditions of approval Exhibit "A" shall be incorporated into the Building Division and field sets of plans. 13. Prior to issuance of building permits, the applicant shall submit to the Planning Division an additional copy of the approved architectural plans for inclusion in the coastal development permit file. The plans shall be identical to those approved by all City departments for building permit issuance. The approved copy shall include architectural sheets only and shall be reduced in size to 11 inches by 17 inches. The plans shall accurately depict the elements approved by this coastal development permit. 14. Prior to issuance of building permits, the applicant shall submit a final construction erosion control plan. The plan shall be subject to review and approval by the Building Division. 15. Prior to issuance of building permits, the applicant shall submit a final landscape and irrigation plan. These plans shall incorporate drought tolerant plantings, non-invasive plant species and water efficient irrigation design. The plans shall be approved by the Planning Division. 16. All landscape materials and irrigation systems shall be maintained in accordance with the approved landscape plan. All landscaped areas shall be maintained in a healthy and growing condition and shall receive regular pruning, fertilizing, mowing, and trimming. All landscaped areas shall be kept free of weeds and debris. All irrigation systems shall be kept operable, including adjustments, replacements, repairs, and cleaning as part of regular maintenance. 17. Prior to issuance of building permits, the applicant shall pay any unpaid administrative costs associated with the processing of this application to the Planning Division. 18. No demolition or construction materials, equipment debris, or waste, shall be placed or stored in a location that would enter sensitive habitat, receiving waters, or a storm drain or result in impacts to environmentally sensitive habitat areas, streams, wetland or their buffers. 13 Zoning Administrator Resolution No. ZA2019-### Paqe 8 of 9 19. The discharge of any hazardous materials into storm sewer systems or receiving waters shall be prohibited. Machinery and equipment shall be maintained and washed in confined areas specifically designed to control runoff. A designated fueling and vehicle maintenance area with appropriate berms and protection to prevent spillage shall be provided as far away from storm drain systems or receiving waters as possible. 20. Debris from demolition shall be removed from work areas each day and removed from the project site within 24 hours of the completion of the project. Stockpiles and construction materials shall be covered, enclosed on all sites, not stored in contact with the soil, and located as far away as possible from drain inlets and any waterway. 21. Trash and debris shall be disposed in proper trash and recycling receptacles at the end of each construction day. Solid waste, including excess concrete, shall be disposed in adequate disposal facilities at a legal disposal site or recycled at a recycling facility. 22. Should the property be sold or otherwise come under different ownership, any future owners or assignees shall be notified of the conditions of this approval by the current property owner or agent. 23. The applicant is responsible for compliance with the Migratory Bird Treaty Act (MBTA). In compliance with the MBTA, grading, brush removal, building demolition, tree trimming, and similar construction activities shall occur between August 16 and January 31, outside of the peak nesting period. If such activities must occur inside the peak nesting season from February 1 to August 15, compliance with the following is required to prevent the taking of native birds pursuant to MBTA: A. The construction area shall be inspected for active nests. If birds are observed flying from a nest or sitting on a nest, it can be assumed that the nest is active. Construction activity within 300 feet of an active nest shall be delayed until the nest is no longer active. Continue to observe the nest until the chicks have left the nest and activity is no longer observed. When the nest is no longer active, construction activity can continue in the nest area. B. It is a violation of state and federal law to kill or harm a native bird. To ensure compliance, consider hiring a biologist to assist with the survey for nesting birds, and to determine when it is safe to commence construction activities. If an active nest is found, one or two short follow-up surveys will be necessary to check on the nest and determine when the nest is no longer active. 24. To the fullest extent permitted by law, applicant shall indemnify, defend and hold harmless City, its City Council, its boards and commissions, officials, officers, employees, and agents from and against any and all claims, demands, obligations, damages, actions, causes of action, suits, losses, judgments, fines, penalties, liabilities, costs and expenses (including without limitation, attorney's fees, disbursements and court costs) of every kind and nature whatsoever which may arise from or in any manner relate (directly or indirectly) to City's approval of McLain Residence including, but not limited to, Coastal Development Permit In Zoning Administrator Resolution No. ZA2019-### Paqe 9 of 9 No. CD2018-091 (PA2018-219). This indemnification shall include, but not be limited to, damages awarded against the City, if any, costs of suit, attorneys' fees, and other expenses incurred in connection with such claim, action, causes of action, suit or proceeding whether incurred by applicant, City, and/orthe parties initiating or bringing such proceeding. The applicant shall indemnify the City for all of City's costs, attorneys' fees, and damages, which City incurs in enforcing the indemnification provisions set forth in this condition. The applicant shall pay to the City upon demand any amount owed to the City pursuant to the indemnification requirements prescribed in this condition. 15 Attachment No. ZA 2 Vicinity Map 03/13/2018 10 VICINITY MAP Coastal Development Permit No. CD2018-091 PA2018-219 2168 East Ocean Front 03/13/2018 1 `� Attachment No. ZA 3 Project Plans 03/13/2018 28 � � IM F «� bb.wbobo-o mommoomm00000 oil I I <:yy IS • ti • s It 1. All work, including materials and workmanship, shall conform to the requirements of local codes, laws, and ordinances and as specified by all by all governing authorities where applicable. Reference is to the latest accepted edition or revision. In the event of conflict with code requirements, that code requirement or note which establishes the higher standard shall take precedence. 2. The intention of the Contract Documents is to include all labor and materials, equipment, and transportation necessary for the complete and proper execution of the work. 3. The Contractor shall visit the job site prior to bidding any portion of the work. The Contractor shall verify all dimensions and conditions prior to beginning work. Should any condition where the intent of the drawings is in doubt or where there is a discrepancy between the Contract Documents and the field conditions, or within the Contract Documents, the Contractor shall notify the Architect immediately for clarification. 4. Dimensions are finished dimensions, from face of gyp to face of gyp or as indicated on drawings, unless noted otherwise. 5. Written dimensions take precedence. Do not scale drawings. Walls not dimensioned are to align with existing walls or be abutted or applied to existing walls per drawings. Doors are not dimensioned and shown jamb tight, do not set 3" from perpendicular wall to outer edge of door jamb as is typical. 6. Reference to any detail or drawing is for convenience only and does not limit the application of such details or drawings. 7. The design, adequacy and safety of erection bracing, shoring, temporary supports, etc., is the sole responsibility of the Contractor. The Contractor shall be responsible for the stability of the structure and provide necessary bracing prior to the application of all shear walls, roof and floor diaphragms, and finish materials. The Contractor shall be responsible for initiating, maintaining, and supervising all safety precautions and programs in connection with the work. 8. The Structural, Mechanical, Plumbing, and Electrical Drawings, as well as the drawings of other consultants, are supplementary to the Architectural Drawings. It shall be the responsibility of the General Contractor to check with the Architectural Drawings before the installation of work shown on the drawings of consultants. The Contractor shall bring any discrepancy between the Architectural Drawings and the drawings of the consulting engineers to the attention of the Architect for clarification. Any work installed in conflict with the Architectural drawings and not brought to the Architect's attention shall be corrected by the Contractor at the Contractor's expense and at no expense to the Owner or Architect. 9 Prior to performance of work, the Contractor shall require each subcontractor to notify the Contractor of any work called out in the drawings for his trade that cannot be fully guaranteed. 10. Contractor shall verify the location and size of all openings with all drawings and manufactured items where applicable. 11. The Contractor shall supervise and direct the Work and be solely responsible for all construction, means, methods, techniques, sequences, and procedures, and for coordinating all portions of the Work. 12. The Contractor herein agrees to repair or replace any or all work, together with any other adjacent work which may be displaced in connection with such replacement, that may prove to be defective in workmanship or materials within a period of one year form the date of acceptance, ordinary wear and unusual abuse or neglect excepted. 13. Contractor shall protect all existing structures, landscaping, materials, etc., during construction. Contractor shall patch and repair all surfaces disrupted or damaged during construction to match existing adjacent surfaces. 14. The Contractor shall on a daily basis keep the premises free form all accumulations of waste material or rubbish caused by his employees, subcontractors, or work, and at the completion of the work shall remove all rubbish, debris, equipment, and surplus materials from in and about the building and leave the premises "broom clean". 15. Any deviation from the Construction Documents or specifications by the Contractor or Owner without the Architect's approval releases the Architect of responsibility and liability in connection with all work so involved. 16. Clarifications on and/or inconsistencies with the drawings and specifications shall be brought to the attention of the Architect by the Contractor prior to commencement of work. Additional charges will not be granted based on claims of incomplete, inaccurate, or inconsistent drawings and specifications. 17. The requirements of Title 24 relating to energy conservation are taken into consideration in the design / construction of this project. 18. Licensed civil engineer that prepared the drainage plan shall certify at the completion of the project that the site drainage is in susbstantial compliance with the approved drainage plan. 19. Building 3 or more stories require structural obsversations by design engineer. 20. Owners on adjacent properties that must underpin their buildings due to the proposed excavation shall be notified in writing ten days prior to beginning the excavation. Copies of these notification letter shall be provided to the city prior to beginning the excavation. 21. Omit. 22. All applicable provisions of the California Building Code with the City of Newport Beach Amendments shall be adhered to in the construction of this project. It is the Contractor's responsibility to construct the project as per these codes. 23. The Contractor shall comply with current editions of all applicable codes and ordinances. The Contractor shall obtain all permits necessary to complete the work, including the Building Permit which the Owner shall pay for prior to the start of the work. Before final acceptance of any part of the work, the Contractor shall furnish the Architect with "Certificates of Inspection" and "Certificates of Occupancy" stating that the work has been approved by the Building Department. 24. The Contractor shall carry all needed insurance, licenses, fees, permits, taxes as required by law for the duration of the project. 25. The Contractor shall maintain liability insurance to protect himself and indemnify and hold the Owner and the Architect harmless from any and all claims for damages, for personal boli injury or death, or property damage during the course of the contract. Fire Insurance shall be maintained by the Owner. 26. The Contractor shall provide sufficent means for protecting existing construction, new construction and materials from damage by other trades, weather, vandals for the course of the project. The Contractor shall provide all barricades, fences and other items required by local ordinances and codes. 27. All plumbing fixtures, lighting fixtures, door hardware, finishes, hardware and miscellaneous items shall be selected and or approved by the Owner and Architect. "Or approved equal" means equal approved by the Architect. 28. Field samples and mock-ups shall be prepared at the site by the Contractor. Affected finish work shall not be started until the Architect has accepted as satisfactory the field samples and or mock up in writing. 29. If the Contractor desires to use any other brand or manufacturer of equal quality, appearance and utility to the product specified, he shall request a subsbution to the Architect with specifications and samples. The Architect will accept or reject the request for substitution and his decision will be final. Unless substitutions are requested as provided herein, deviations from the drawings and specifiacations will not be permited. 30. The Owner may order extra work or make changes by altering, adding to, or deducting from the work with a formal "Change Order". The contract sum shall be adjusted accordingly Changes or alterations shall be approved by the Architect prior to the start of any work. 31. The Architect will in no way be responsible for how the work is performed, safety in, on or about the job site, nor means, methods or timeliness in the performance of the work. 32. The Architect reserves the right to reject any materials and work quality which are not considered to be up to the highest standards of the various trades involved. Such inferior material or work quality shall be repaired or replaced as directed by the Owner at no additional cost to the Owner. 33. All findings of the Soils Report as prepared by the Geotechnical Engineer are part of these plans. 34. The Contractor shall notify the Architect immediately for direction in the event that any unusual conditions not covered by these plans are encountered during construction. 35. The Contractor shall have a superintendant at the job site whenever any work under this Contract is being performed in order to provide constant supervision. 36. The Contractor shall maintain the job site in a neat and safe condition in accordance with Title 8 of the Construction Safety Orders at all times during the construction period. The Contractor shall on a weekly basis, clean up, remove and dispose of all debris from the job. 37. The Contractor shall provide and locate all ducts, accces panels and return air grilles as required for the mechanical system. Prior to any mechanical work, the Contractor shall provide the Architect with drawings of the proposed locations of the above items. The Architect shall approve the drawings and the locations before any work shall begin. 38. All shoring and bracing necessary for construction of the project is the sole responsibility of the Contractor 39. The Contractor shall submit 2 copies of required shop drawings, cut sheets, materials samples used in the project to the Architect before purchase and delivery to the site. All shop drawings shall be approved by the Architect. The Architect's approval of such drawings shall not relieve the Contractor of responsibility for errors of any sort pertaining to the shop drawir The Architect's approval is merely a review for the limited purpose of checking for conformance with the information given and the design concept expressed in the Contract Documents. The Contractor is responsible for the adequacy of the performance, dimensions given and the design criteria required by the Contract Documents. 40. All electrical shall be under ground to the nearest utility pole or transformer. The Contractor shall be responsible for any damage to utility lines. Where utility lines must be maintained under a building, they must be properly sleeved through foundation walls. 11 Jill M1111111111 2 Section Number Sheet Number 3 Detail Number 2 Sheet Number 1 Sheet Number 4 <A 2 Interior Elevation 3 �_ Number 0 Door symbol - see door schedule OWindow symbol - see window schedule ® Keynote symbol - see keynotes Ceiling height symbol 0 2 x stud wall 0 Concrete Block wall o Low wall - refer to spot elevation A.B. ANCHOR BOLT I.D. INSIDE DIAMETER A.C. ASPHALT CONCRETE IN INCH A.F.F. ABOVE FINISH FLOOR INS INSULATION ALUM ALUMINUM INT INTERIOR ALT ALTERNATE JAN. JANITOR APPROX APPROXIMATE JT JOINT ARCH ARCHITECTURAL KIT KITCHEN BD BOARD L LENGTH BEL BELOW LAV LAVATORY BET BETWEEN M.C. MEDICINE CHEST BLDG BUILDING M.O. MASONRYOPENING BM BEAM MAS MASONRY BOT BOTTOM MAX MAXIMUM BW BOTH WAYS MECH MECHANICAL C.J. CEILING JOISTS MED MEDIUM C.M.U. CONCRETE MET METAL MASONRYUNITS MFG MANUFACTURER C.O. CLEAR OPENING MIN MINIMUM CAB CABINET MISC. MISCELLANEOUS CEILG CEILING MTD MOUNTED CEM CEMENT (N) NEW CER CERAMIC N.I.C. NOT IN CONTRACT CLR CLEAR N.T.S. NOT TO SCALE COL COLUMN NAT NATURAL CONC CONCRETE O.C. ON CENTER CONN CONNECTION O.D. OUTSIDE DIAMETER CONST CONSTURUCTION OPG OPENING CONT CONTINUOUS OPP OPPOSITE CONTR CONTRACTOR P.S.I. POUNDSISQUARE D DEPTH INCH D.F. DRINKING FOUNTAIN, PL PLATE D.F. DOUGLAS FIR PLAS PLASTER D.S. DOWNSPOUT PLY PLYWOOD DBL DOUBLE POL POLISH, POLISHED DET DETAIL PR PAIR DIA DIAMETER PTD. PAINTED DIM DIMENSION R RADIUS, RAFTER DN DOWN R.D. ROOF DRAIN DR DOOR R.O. ROUGH OPENING DWG DRAWING R.R. ROOF RAFTER DWR DRAWER R.S. ROUGH SAWN E.N. EDGE NAIL(ING) RA RETURN AIR E.W. EACH WAY REQ REQUIRED EA EACH RI RISER ELEC ELECTRIC, RM ROOM ELEC ELECTRICAL S.S. STAINLESS STEEL ELEV ELEVATION S.C. SOLID CORE E.G. EXISTING GRADE SCH SCHEDULE E.P. EXISTING PAVING SECT SECTION EQ EQUAL SH SHELF EQUIP EQUIPMENT SHTG SHEATHING EXH EXHAUST SIM SIMILAR EXIST(E) EXISTING SPEC SPECIFICATIONS EXP EXPOSED SQ SQUARE F.N. FIELD NAILING STD STANDARD F.O.C. FACE OF CONCRETE STL STEEL F.O.M. FACE OF MASONRY STRUCT STRUCTURAL F.O.S. FACE OF STUD OR SYM SYMMETRICAL FRMG. FRAMING T 6 B TOP AND BOTTOM F.G. FINISH GRADE T 8 G TOUNGE AND GROOVE FIN FINISH T TREAD, F.F. FINISH FLOOR TEMP TEMPERED GLASS F.S. FINISH SURFACE TC, TOP OF CURB FT FOOT T.C. TOP OF CHIMNEY FTG FOOTING T.W. TOP OF WALL GA GAUGE TR, TOP OF ROOF GAILY GALVINIZED THK THICK G.F.I. GROUND FAULT T.T. TOP OF TRELLIS INTERRUPTOR TYP TYPICAL G.F.R.C. GLASS FIBER U.N.O. UNLESS NOTED OTHERWISE REINFORCED CEMENT UR URINAL G.I. GALVINIZED IRON V.T. VINYL TILE GL GLASS V.T.R. VENT THROUGH ROOF GR GRANITE W WIDE, WIDTH GRD GRADE W.C. WATER CLOSET, GYP. BD. GYPSUM BOARD WALL COVERING H.M. HOLLOW METAL W/ WITH H.C. HOLLOW CORE WD WOOD HC HANDICAPPED WP WATERPROOF HD HIGH DENSITY, W.R. WATER RESISTANT HD HOLD DOWN How HARDWARE HR HOUR HT HEIGHT HTR HEATER OWNER Helle Mclain 8 Strands 913 Balmoral 2 Freed Street London, UK W21JN ARCHITECT GRAHAM ARCHITECTURE 1075 N. Coast Hwy. Laguna Beach, CA 92651 Carlton Graham (949)715-2365 SURVEYOR GUIDA SURVEYING INC. 9241 Irvine Blvd., Suite 100 Irvine, Ca 92618 Guillermo Arredondo (949)777-2000 GEOLOGIST R MCCARTHY CONSULTING INC. 23 Corporate Plaza, Suite 150 Newport Beach, CA 92660 Robert McCarthy (949)629-2539 CONTRACTOR T.B.D. STRUCTURAL ENGINEER T.B.D. PROJECT ADDRESS: 2168 EAST OCEANFRONT, NEWPORT BEACH, CA 92661 LEGAL DESCRIPTION: LOT 18, TRACT 518, NEWPORT BEACH, CALIFORNIA, ORANGE COUNTY Al 048-282-38 PROJECT DEMO AN EXISTING TWO STORY RESIDENCE AND CONSTRUCT A NEW TWO STORY DESCRIPTION: RESIDENCE. CODE ANALYSIS: CODE: CBC, Cl Cl CEC CONSTRUCTION TYPE: V -B -SPR OCCUPANCY TYPE: R3 - U STORIES: TWO ZONE: R1 SINGLE UNIT RESIDENTIAL SETBACKS: FRONT (BEACH) =10'-0" REAR (ALLEY) = 0'-0" SIDES = 4'-0" EACH SIDE MAX. HEIGHT LIMIT: FLAT ROOF = 24'-0" SLOPED ROOF = 29'-0" (3:12 PITCH MIN.) MAX. HEIGHT LIMIT ELEVATION DETERMINATION: BASE FLOOD F.F. ELEV. = 9.0' MIN. (PER NAVD 88) BASED ON 4 CORNERS OF LOWER FOOTPRINT: MAX HEIGHT ELEV. DETERMINATION CALC. MAX. BUILDING HEIGHT ELEV. =14.14' + 29.0'= 43.14' CORNER (E.)GRADES AT (N.) (FOR 3:12 SLOPED ROOF) MAX. BUILDING HEIGHT ELEV. =14.14' + 24.0'= 38.14' (FOR FLAT ROOF) EXISTING SITE SLOPE PERCENTAGE DETERMINATION: LOT SLOPE CALCULATION CORNER FOOTPRINT CORNERS (FT) N.W. 13.39 N.E. 13.40 S.W. 14.88 S.E. 14.89 = 101.4 TOTALGARAGE AVG. (E.) GRADE 14.14 MAX. BUILDING HEIGHT ELEV. =14.14' + 24.0'= 38.14' (FOR FLAT ROOF) EXISTING SITE SLOPE PERCENTAGE DETERMINATION: LOT SLOPE CALCULATION CORNER (E.) GRADES AT FOOTPRINT CORNERS FT (HIGHEST) S.E. 14.89 (LOWEST) N.W. 13.39 TOTAL HABITABLE DISTANCE BETWEEN 78.50 = 101.4 TOTALGARAGE AVG. LOT SLOPE (%) 1.91 MAX. FLOOR AREA RATIO (FAR): BUILDABLE AREA = GROSS LOT AREA (4,175 SF) - THE REQUIRED SETBACKS (1,121 SF) BUILDABLE AREA = 3,054 SF BUILDABLE AREA X 2 = 6,108 SF MAX. TOAL AREA (INCLUDING PATIO / DECK) = 5,042 SF CONCLUSION = 5,042 SF IS LESS THAN 6,108 SF MAX ALLOW. = PROJECT COMPLIES OK LOT COVERAGE: TOTAL HABITABLE 1ST FLOOR AREA+ GARAGE + MECH. = 2,393 SF FOOTPRINT LOWER FOOTPRINT / BUILDABLE AREA = 2,393 SF / 3,054 SF = 78.4% MINIMUM OPEN SPACE VOLUME AREA: 15% X BUILDABLE LOT AREA (3,054 SF) = 458.1 SF 1ST FLOOR OPEN VOLUMES = 562 SF 2ND FLOOR OPEN VOLUMES = 813 SF TOTAL OPEN VOLUMES =1,375 SF 1,375 SF > 458.1 SF = OK AREA CALCULATIONS: AREA CALCULATIONS (SF) TOTAL LOWER LEVEL HAB. = 1,722.0 TOTAL UPPER LEVEL HAB. = 2,012.5 TOTAL HABITABLE = 3,734.5 TOTAL MECH. / ELEC. = 101.4 TOTALGARAGE = 447.2 TOTALSTORAGE = 122.4 TOTAL DECK / PATIO = 636.6 1. FIRE SPRINKLERS - DETAILED DRAWINGS AND SPECS SHALL BE SUBMITTED TO THE BUILDING / FIRE DEPARTMENT architecture 1075 N. COAST HIGHWAY LAGUNA BEACH, CA 92651 TEL: 949.715.2365 FAX: 949.715.2574 E: CARLTON@GRAHAMARCHITECTURE.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO GRAHAM ARCHITECTURE AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF GRAHAM ARCHITECTURE Vmft (40 (' JIM w �w cc 0 CILk U Z LIJ Ismw 0 LIL W 0 C6 Lou w (40 t*ft N ISSUE: 10.09.2018 REVISION DATE DESCRIPTION 0 11.05.18 ZONING CORR. 0 0 SCALE: TITLE SHEET FND LTT 'CS 6902" FLUSH FND LTT (S 6902" FLUSH — _ FND MON CHIZ X NA ALLEY FND L TT " _ LS 4653" FLUSy � - FND LTT 'CS 4653" FLUSH Basis of Bearinqs: THE BEARINGS SHOWN HEREON ARE BASED UPON THE CENTERLINE OF CHANNEL ROAD BEING N 15°00'00" W, PER TRACT NO. 518, BK. 17, PGS. 33-36 OF MISCELLANEOUS MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF ORANGE COUNTY, CALIFORNIA. Benchmark Note: THE ELEVATIONS SHOWN HEREON ARE BASED ON ORANGE COUNTY SURVEY VERTICAL CONTROL NUMBER "NB1-40-71", ELEVATION 7.828' (NAVD88) TOPOGRAPHIC VIEW SCALE: 1/8"=1' oSCO —CONCRETE PATTERN MOW m CONCRETE PATjERN� -CONCRETE PATTERN I� SIDEWALK --1 FWn lTT "/Q GF47" rl/l<lP Leaend BOO BUILDING OUTLINE 0/H OVERHANG BRL BREAKLINE BW BACK OF WALL EOC EDGE OF CONCRETE EVLT ELECTRIC VAULT + 31.86 " (JO 27 N,/ 0 FL FLOWLINE 0� ' (1508) BDO/EOC I BDO �T I ��j/ I BU/LD/NG FOOTPRINT I / 1 UPPER FF FINISH FLOOR 1573) BDO (3253 FS FINISH SURFACE —� 88) ���� �� 01 B 10 / ) 0/H LIP LIP OF GUTTER _ O_VERHANG UPPER ROOF_ o ' OVERHANG— i— BALCONY — — MOW MOW STRIP (14,91) EOC (15 01) EOC — _ ' 41' _ L' (1342) BDO PEX PIPE EXPOSED 05 59) TURFS (3493) 0/H — _ (2265 +(14.70 (1474) WALL/FS�ROCA' (3321 (1489 WALL + H SG SINGLE GATE (14.69 / ) (14 81 (1471 ) 0/H h — BDO LOWER J WALL FS _ ) EOC J WALL FS 14.92) EOC � L — — �— STRS STAIRS _ 6ALC0/V y 4--00'18'01,,(1776) TW 6g-7 TOP TOP OF SLOPE (14 84 L=45.00' (1533)+ S ) EOC (14.82)+ +(1349) "� • 1;'1133,66 WALL WALLS (14.69) EOC (1517) { (14.66 ) EOC , TURFS 8=8590.00' 15 '(1370) WIND WINDOW (1632)+ DTa BIB '9 10) TW BLOCK WALL NATURAL• FOUND MONUMENT GROUND oSCO SEWER CLEANOUT NATURAL GROUND G SEWER MANHOLE x (n2.22) SPOT ELEVATION (16.44)+ Date of Survey 0WV WATER VALVE (16 57) + (16.54)+ APRIL 16, 2018 {� TREE � SAND - (1797)+ (1751)+ - SAND , (1764)+ (16.33)+ (16.25)+ (1792)+ -SAND � Surveyor's Statement THIS MAP WAS PREPARED BY ME OR UNDER MY DIRECTION AND IS BASED ON A FIELD SURVEY PERFORMED IN APRIL 2018 RALPH W. GUIDA, IV P.L.S. 7076 m ,� o Ralph W. Guido. IV z /18/18 Nc.777- DATE: 77DAE: 6 Z o z00O to N — O U o IS z (Wy. A 0) (DIE F N ¢ N li QX N d > m � [1 0 a m QN Z0 "a Vno � Lj �ZCD ,R v N ONi�� w EXISTING SURVEY A-0.0 311 W Q a z 21 Z Z Z M 0 LL m "a J V qZ W /_ V 0 O N m a CD 0 N 3 W Z C7 O O EXISTING SURVEY A-0.0 311 W Q a z 21 O 1 Q Z L \ - 19.50) TW �! +( 8) 5.7 +(15.82) (15.93) + I C)3 oil 00 CD 0 O O E.G. 14.90' � O 1 �\,C:)O\ \� 0 O v N N N N N,)C �� O> <O Oo 0 Oo O 1 O Z: O �� � �(": \) 7 0 0 0 0 0 00 0 _ QD 00 O = _ O O O O O / O ------ --- ---- --- \\�� J// (15.79) (15.91)+\ LNC°47'3 6 E 91.88, I -1-(15.72) +(15. CONCRETE(13.76) I ITl EDO v v O O 00 v O I � O I O 1 C Q -,i F-1�O � T7 V W O O O I I oil 00 CD 0 O O E.G. 14.90' � O 1 �\,C:)O\ \� 0 O v N N N N N,)C �� O> <O Oo 0 Oo O 1 O Z: O �� � �(": \) 7 0 0 0 0 0 00 0 _ QD 00 O = _ O O O O O / O ------ --- ---- --- \\�� J// (15.79) (15.91)+\ LNC°47'3 6 E 91.88, I -1-(15.72) +(15. CONCRETES----------- ------ - ----- 0 0 (14.74) WALL/FS I c \ \ TBA Q21 Co I \ O O I Z: O I� O = O I00 Tj 4' DOOR --I-`--------------------- O I c� (15.08) FF --- ------------------------ -- ------------- - - - - - ��. _ � (13.71) BRL �� GARAGE DOOR Ln c On 0 n� �I c,, �, l o o (13.81) FF GROUND FLOOR FOOTPRINT L _________________ 2,394 SF = GARAGE DOOR Ov F.F. 14.0' \ O N o BUILDING FOO TPRIN T L o GARAGE D001 o-- - - - - - - - - - - \ .(� --r]/. (13.83) FF I o I J (E.) 14.89' (23. 13) 0 + (15.45)+ I I I � I � I = O ® CD O \OI, —I CD OI :�E I fT"1 1 70 I � a� CONCRETE(13.76) I ITl EDO v v O O (21.91) 0%H (14.35 WALL/�� (13.64) BRL IG-) O � O I O 1 C Q -,i I� CONCRETES----------- ------ - ----- 0 0 (14.74) WALL/FS I c \ \ TBA Q21 Co I \ O O I Z: O I� O = O I00 Tj 4' DOOR --I-`--------------------- O I c� (15.08) FF --- ------------------------ -- ------------- - - - - - ��. _ � (13.71) BRL �� GARAGE DOOR Ln c On 0 n� �I c,, �, l o o (13.81) FF GROUND FLOOR FOOTPRINT L _________________ 2,394 SF = GARAGE DOOR Ov F.F. 14.0' \ O N o BUILDING FOO TPRIN T L o GARAGE D001 o-- - - - - - - - - - - \ .(� --r]/. (13.83) FF I o I J (E.) 14.89' (23. 13) 0 + (15.45)+ I I I � I � I = O ® CD O \OI, —I CD OI :�E I fT"1 1 70 I � a� .h ;H 'H — CONCRETE(13.76) I ITl EDO o (LOWEST) N.W. (14.81) WALL/FS (14.62) WALL/FS (21.91) 0%H (14.35 WALL/�� (13.64) BRL IG-) — H F T Fr I � 1 C Q -,i I� � T7 V W O O 0 'tom .h ;H 'H — CONCRETE(13.76) I ITl EDO o (LOWEST) N.W. (14.81) WALL/FS (14.62) WALL/FS (21.91) 0%H (14.35 WALL/�� (13.64) BRL IG-) — H F (13.34)+ N09°29'35"E k 13.34 70 x(13`30)1 +(13.26) +(13.31) +(13.24) ', +(13.20) o -- ----------------- - - - - - - - - - - - - --- --- - -rill N N N v O o> O o> O O <o � N � O \ O O 0 0= O\ I I O = I I� 7-D I ITl O o (LOWEST) N.W. 13.39 C – —77 (E.) 13.40' DISTANCE BETWEEN (13.34)+ N09°29'35"E k 13.34 70 x(13`30)1 +(13.26) +(13.31) +(13.24) ', +(13.20) o -- ----------------- - - - - - - - - - - - - --- --- - -rill N N N v O o> O o> O O <o � N � O \ O O 0 0= O\ I I O = I I� 7-D I ITl O 1� (LOWEST) N.W. 13.39 C ID DISTANCE BETWEEN IG-) -i T Fr I � 1 C I� � T7 LOT SLOPE CALCULATION CORNER (E.) GRADES AT FOOTPRINT CORNERS FT (HIGHEST) S.E. 14.89 (LOWEST) N.W. 13.39 13.40 S.W. DISTANCE BETWEEN 78.50 14.89 T AVG. LOT SLOPE (%) 1.91 MAX HEIGHT ELEV. DETERMINATION CALC. CORNER (E.) GRADES AT (N.) FOOTPRINT CORNERS (FT) N.W. 13.39 N. E. 13.40 S.W. 14.88 S. E. 14.89 T AVG. (E.) GRADE 14.14 I Max. Building Ht. Elevation = 14.14'+ 24.0'= 38.14' flat roof Max. Building Ht. Elevation = 14.14'+ 29.0'= 43.14' 3:12 roof I I I FT�Al I 7�) I O I F.S. 12.50' nnnnnnnnn_ 1 30' ' V ti n � � \13 CD N3 titi o � T r o N F1 !v nnnnnnnnn_ 1 30' N ti n � � \13 CD N3 titi o � ti r o N F1 !v 0 'tom it r` N nnnnnnnnn_ 1 30' �2 1 O l` TD G RA H ALI V LJ architecture 1075 N. COAST HIGHWAY LAGUNA BEACH, CA 92651 TEL: 949.715.2365 FAX: 949.715.2574 E: CARLTON@GRAHAMARCHITECTURE.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO GRAHAM ARCHITECTURE AND IS FURNISHED IN T�T CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, " II BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS RJ MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS I WITHOUT THE PRIOR WRITTEN CONSENT OF GRAHAM \ ARCHITECTURE 30 ISSUE: 10.09.2018 REVISION DATE DESCRIPTION /i 11.05.18 ZONING CORR. 0 SCALE: 1/4" = 1'-0" LOT SLOPE/ MAX. HEIGHT CALCS. A-0.1 I n � � \13 N3 titi ti r o N \ !v r` x I I F.S. 12.48' �2 1 O l` TD G RA H ALI V LJ architecture 1075 N. COAST HIGHWAY LAGUNA BEACH, CA 92651 TEL: 949.715.2365 FAX: 949.715.2574 E: CARLTON@GRAHAMARCHITECTURE.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO GRAHAM ARCHITECTURE AND IS FURNISHED IN T�T CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, " II BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS RJ MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS I WITHOUT THE PRIOR WRITTEN CONSENT OF GRAHAM \ ARCHITECTURE 30 ISSUE: 10.09.2018 REVISION DATE DESCRIPTION /i 11.05.18 ZONING CORR. 0 SCALE: 1/4" = 1'-0" LOT SLOPE/ MAX. HEIGHT CALCS. A-0.1 I n � � r �2 1 O l` TD G RA H ALI V LJ architecture 1075 N. COAST HIGHWAY LAGUNA BEACH, CA 92651 TEL: 949.715.2365 FAX: 949.715.2574 E: CARLTON@GRAHAMARCHITECTURE.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO GRAHAM ARCHITECTURE AND IS FURNISHED IN T�T CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, " II BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS RJ MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS I WITHOUT THE PRIOR WRITTEN CONSENT OF GRAHAM \ ARCHITECTURE 30 ISSUE: 10.09.2018 REVISION DATE DESCRIPTION /i 11.05.18 ZONING CORR. 0 SCALE: 1/4" = 1'-0" LOT SLOPE/ MAX. HEIGHT CALCS. A-0.1 9 E.G. 5" THICK CONC. STEPS TOPCAST FINISH 2' HIGH BOARD FORMED CONC. WALL 16.00' TW F.S. 15.17' "cm M CAST IN PLACE CONC. FIRE PIT 16.00' F.S. W LU CITY R.O.W. beach sand LL 9 5" THICK CONC. FLATWORK TOPCAST FINISH / SAW CUT JOINTS E.G. 14.90' (E.) RESIDENCE 10'-0" I 70'-111/2" CAST IN PLACE CONC. P DS 5" THICK CONC. FLATWORK ' (N.) 6' HIGH BLOCK SITE WALL 5" THICK CONC. STEPS 5" THICK CONC. FLATWORK 5" THICK / TOPCAST FINISH TOPCAST FINISH I SAW CUT JOINTS SMOOTH STUCCO FINISH TOPCAST FINISH TOPCAST FINISH / SAW CUT JOINTS L = 91.88' (15 UP 5' GATE' ' F.S. 13.92:.. .. v F_— ---------------.------------.----------------------- N ----or-- RDOFABOVE77 5r — — — — — — 2ND FLOOR ABOVE UP' O O I F.S. 13.92' F:S.-13.92' F.S. 12.77' .. .0( O O I FRONT ENTRY ..I O O I O O I' . I O O LU >OIM .QI Y U . .w 0 BEACH TERRACE F.S. 13.92' F.Y.S.B. GROUND FLOOR FOOTPRINT 2,394 SF F.F. 14.0' O O a .. F.S 13:92' . F.S..13.04' 5' GATE F.S. 13.92' - O O 8'-101/2° oCD • N 2 .. L = 94.70' CAST IN PLACE CONC. PADS (E.) 6' HIGH BLOCK SITE WALL 5" THICK / TOPGASTE NISH SMOOTH STUCCO FINISH 10'-11/2" 66-11 112" (E.) RESIDENCE 10'-11" ;AST IN PLACE CONC. PADS 5" THICK/ TOPCAST FINISH PROPERTY LINE .SETBACK/ — F.S. 12.77' I VAULT ELEC. i F.S. 12.50' 1 2' HIGH BOARD FORMED CONCI WALL 20" X X MAIL BOX STONENE VENEER CLAD WM 5" THICK CONC. FLATWORK TOPCAST FINISH / SAW CUT JOINTS ST IN PLACE CONC. PADS THICK / TOPCAST FINISH 17'-7 1/2" NOTE: All structures within the front setback are limited to 42" in height as measured from existing, pre -construction grade. �z MHSS 11.90' 0 0 r• rR AL'I itecture 1075 N. COAST HIGHWAY LAGUNA BEACH, CA 92651 TEL: 949.715.2365 FAX: 949.715.2574 E: CARLTON@GRAHAMARCHITECTURE.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO GRAHAM ARCHITECTURE AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF GRAHAM ARCHITECTURE Vow (40 N 0' Q X 0 qIzz Uj cc FWAMM cc Uj Uj O LAL hUl,-j cc (40 VwftZ V N ISSUE: 10.09.2018 REVISION DATE DESCRIPTION ZL - 0 SCALE: 1/4" = 1'-0" SITE PLAN Aml nO 2:_�' CAST IN PLACE CONC. PADS I r--------------------------------1 5"THICK /TOPCAST FINISH I I F.S. 13.04' F.S.12.7T I F.S. 12.38' i 6" X 6" FLAMED BASALT PAVERS ON 2" SAND BED 2.-6., I I DRIVEWAY roof eave 1 2% SLOPE I a Z I GARAGE GARAGE FROND F.S. 13.04' 16'-61/2" ALLEY z 20'-0" X 20'-3" I I 0 INSIDE I > w I m l 01 w I p l �� 0 o l 0� ZI i I I I I F.S. 13.04' � L- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - J F r -1 j CAST IN PLACE CONC. PADS I TRASH 1 I 5" THICK/ TOPCAST FINISH I ENCLOSURE I I 1 L__L L__-1 F.S. 13 Oa' m�5 MM GATE 1 w o F.S.12.48' 5" THICK CONC. FLATWORK TOPCAST FINISH / SAW CUT JOINTS ST IN PLACE CONC. PADS THICK / TOPCAST FINISH 17'-7 1/2" NOTE: All structures within the front setback are limited to 42" in height as measured from existing, pre -construction grade. �z MHSS 11.90' 0 0 r• rR AL'I itecture 1075 N. COAST HIGHWAY LAGUNA BEACH, CA 92651 TEL: 949.715.2365 FAX: 949.715.2574 E: CARLTON@GRAHAMARCHITECTURE.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO GRAHAM ARCHITECTURE AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF GRAHAM ARCHITECTURE Vow (40 N 0' Q X 0 qIzz Uj cc FWAMM cc Uj Uj O LAL hUl,-j cc (40 VwftZ V N ISSUE: 10.09.2018 REVISION DATE DESCRIPTION ZL - 0 SCALE: 1/4" = 1'-0" SITE PLAN Aml nO 2:_�' E.G. 5" THICK CONC. STEPS TOPCAST FINISH PENNISETUM ORIENTAL/ ORIENTAL FOUNTAIN GRASS 1 GAL. 2' HIGH BOARD FORMED CONC. WALL 16.00' TW F.S. 1 CAST IN PLACE CONC. FIRE PIT 16.00' F.S. CITY R.O.W. beach sand 5" THICK CONC. FLATWORK TOPCAST FINISH / SAW CUT JOINTS PENNISETUM ORIENTAL I ORIENTAL FOUNTAIN GRASS 1 GAL. E.G. T AREA CALCS (SF) LANDSCAPE TOTAL HARDSCAPE (driveway not Inc.) 257 TOTAL CAST IN PLACE CONC. PADS 5" THICK CONC. FLATWORK (N.) 6' HIGH BLOCK SITE WALL 5" THICK CONC. STEPS 5" THICK CONC. FLATWORK CAST IN PLACE CONC. PADS 5" THICK / TOPCAST FINISH TOPCAST FINISH I SAW CUT JOINTS SMOOTH STUCCO FINISH TOPCAST FINISH TOPCAST FINISH / SAW CUT JOINTS 5" THICK/ TOPCAST FINISH CAST IN PLACE CONC. PADS (E.) 6' HIGH BLOCK SITE WALL 5" THICK CONC. FLATWORK CAST IN PLACE CONC. PADS 5" THICK I TOPCAST FINISH SMOOTH STUCCO FINISH TOPCAST FINISH / SAW CUT JOINTS 5" THICK/ TOPCAST FINISH -IIGH BOARD FORMED CONCI WALL !AVE AMERICANA I CENTURY PLANT 10 GAL. IUISETUM HYEMALE /HORSE IL REED 1 GAL. ;AVE AMERICANA I CENTURY PLANT 10 GAL. I 'X 20" X 48" MAIL BOX TONE VENEER CLAD 'HIOPOGON JAPONICUS / MON 0 GRASS 1 GAL. ,ST IN PLACE CONC. PADS THICK / TOPCAST FINISH X 6" FLAMED BASALT PAVERS ON 2" SAND BED ALLEY ,ST IN PLACE CONC. PADS THICK/ TOPCAST FINISH 'ENNISETUM ORIENTAL/ ;IENTAL FOUNTAIN GRASS 1 GAL. .S. 12.48' �z MHSS 11.90' 0 r itecture 1075 N. COAST HIGHWAY LAGUNA BEACH, CA 92651 TEL: 949.715.2365 FAX: 949.715.2574 E: CARLTON@GRAHAMARCHITECTURE.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO GRAHAM ARCHITECTURE AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF GRAHAM ARCHITECTURE Vow (40 (410 N 0' CQ V r� V uj cc cc CL k U O LL CC �i hul'-j V v♦ w (40 Vftft N ISSUE: 09.14.2018 REVISION DATE DESCRIPTION - ZL - 0 SCALE: 1/4" = 1'-0" LANDSCAPE/ HARDSCAPE PLAN Aml ■ --),4 iD EO M E.G. o0 CD Ci d. y 10'-0" F.Y.S.B. PLANTING I I 0 I I LU of ¢I F.S. 15.17' w LI a - BEACH LU CITY R.O.W. TERRACE j beach sand F.S. 13,92' I I I 10'-0" A5.0 I I I PLANTING C') L I Q 70'-111/2" I I I L = 91.881 C D TUB ART MASTER BEDROOM F.F. 14.00' wood TEAK SLATS CHANGING o W DRAINS BELOW SHOWER/ HANDHELD J ROOM BENCH W w wLU LINEN tile LL WOOd / II CD BENCH / SHOWER = o tile U 00 SHOWER = Lu STOR. tile 1 MASTER BATH F.F. 14.00' F.F. 14.00' V tile wood m U) C D TUB ART MASTER BEDROOM F.F. 14.00' wood HALL F.F. 14.00' tile ELEV. tile COAT CAB. r Z I I I I I POWER I PLATE I I I W.I.C. j LAUNDRY GYM F.F. 14.00' F.F 14.00' F2F wood0' ood e o NORDIC TRACK LIGHT ALCOVE W.I.C. o F.S. 13.50' F.F. 14.00' Wood ELEC. F.F. 13.50' tile - ao o ui v > C6 ENTRY F.S. 13.92' 113.92' FOYER F.F. 14.00' II tile F.S. 13.50' UP 0 N Q 10'-11" PROPERTY LINE F.S. 12.50' SETBACK SETBACK 1 ------- -- --- 1- 1 F.S. 12.77' 0 3 -UP o C? C6 TGATE �8'-101/2�101/2� o d >:o v > vi c� E.G. 14.90' 10'-0" F.Y.S.B. 10'-11/2" L = 94.701 I I I I 66-111/2" MIIUDQ� LIQ W.H. tankless GARAGE 20'-0" x 20'-3" tile INSIDE U FUTU E ECH. STO13/jIn ASH PLANTING 1 I mail I STAIRCASE box wood 1 1 13.08' N Q F.S. 13.04' F.S. 13.04' F.S. 13.04' FS 1277' I I I I DRIVEWAY 2% SLOPE DRIVEWAY basalt pavers >I ml oI of of z N 17'-71/2" F.S. 12.38' r A 0 ALLEY _ _ 1 A5.0 I I I PLANTING 06 ui r vi of o v6 v} F.S. 12.48' Uj NOTE; RADIANT HEATED FLOORS THROUGHOUT AC I HEAT PREP. FOR FUTURE LEGEND NEW STUD WALL NEW CONC. WALL architecture 1075 N. COAST HIGHWAY LAGUNA BEACH, CA 92651 TEL: 949.715.2365 FAX: 949.715.2574 E: CARLTON@GRAHAMARCHITECTURE.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO GRAHAM ARCHITECTURE AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF GRAHAM ARCHITECTURE ISSUE: 09.14.2018 REVISION DATE DESCRIPTION 0 SCALE : 1/4" = 1'-0" FLOOR PLAN LOWER FLOOR A-2.0 CHANGING o W W.0 J ROOM F.F. 14.00' tile LL WOOd / II CD BENCH / HALL F.F. 14.00' tile ELEV. tile COAT CAB. r Z I I I I I POWER I PLATE I I I W.I.C. j LAUNDRY GYM F.F. 14.00' F.F 14.00' F2F wood0' ood e o NORDIC TRACK LIGHT ALCOVE W.I.C. o F.S. 13.50' F.F. 14.00' Wood ELEC. F.F. 13.50' tile - ao o ui v > C6 ENTRY F.S. 13.92' 113.92' FOYER F.F. 14.00' II tile F.S. 13.50' UP 0 N Q 10'-11" PROPERTY LINE F.S. 12.50' SETBACK SETBACK 1 ------- -- --- 1- 1 F.S. 12.77' 0 3 -UP o C? C6 TGATE �8'-101/2�101/2� o d >:o v > vi c� E.G. 14.90' 10'-0" F.Y.S.B. 10'-11/2" L = 94.701 I I I I 66-111/2" MIIUDQ� LIQ W.H. tankless GARAGE 20'-0" x 20'-3" tile INSIDE U FUTU E ECH. STO13/jIn ASH PLANTING 1 I mail I STAIRCASE box wood 1 1 13.08' N Q F.S. 13.04' F.S. 13.04' F.S. 13.04' FS 1277' I I I I DRIVEWAY 2% SLOPE DRIVEWAY basalt pavers >I ml oI of of z N 17'-71/2" F.S. 12.38' r A 0 ALLEY _ _ 1 A5.0 I I I PLANTING 06 ui r vi of o v6 v} F.S. 12.48' Uj NOTE; RADIANT HEATED FLOORS THROUGHOUT AC I HEAT PREP. FOR FUTURE LEGEND NEW STUD WALL NEW CONC. WALL architecture 1075 N. COAST HIGHWAY LAGUNA BEACH, CA 92651 TEL: 949.715.2365 FAX: 949.715.2574 E: CARLTON@GRAHAMARCHITECTURE.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO GRAHAM ARCHITECTURE AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF GRAHAM ARCHITECTURE ISSUE: 09.14.2018 REVISION DATE DESCRIPTION 0 SCALE : 1/4" = 1'-0" FLOOR PLAN LOWER FLOOR A-2.0 10'-0" 70'-11 1/2" F.Y.S.B. DECK _m 9 C L = 45.00, I W 0 m a 0 O O I I L ROOFABOVE — — — — EGRESS HIGH WINDOWS I 1 Ll if; T. SHELVES I CAB. - - - - - - - - - 0 0 oo - - - REF. FRZ. I WIC . 25.50' I F.F. 25.50' z KITCHEN wood I \\ a L — — — I F— I I I DECK I F.S. 25.50' I tile I I I I LU I O 10 � I I I I I I I L_ C?Ui v0 10'-0" F.Y.S.B. 14'-91/2" F.F. 25.50' tile DINING F.F. 25.50' tile F.F. 25.50' tile TV ABOVE FIREPLACE OOF ABOVE 8'-10112" — M Su HT a PWDR n F.F. 25.50' tile "'------111111------"' ELEV. tile GALLERY F.F. 25.50' the / 1 \ \L / BEDROOM F.F. 25.50' wood TV ART PATIO F.S. 25.50' the 1 r --Tr-- i slnk ;ice ;; ref. ', F 7bbq L--JL---J J CV L = 94.701 72'-7" SCULPTURE m o - BATH 2 Z a F.F. 25.50' tile DN r-----7 PULL DN. STAIR 1 I MOTORIZED I L__ ----J SK _1$1GHT - TV m BEDROOM 1 m F.F. 25.50' m 11 o 1� Z w w 0 0 (V ROOFABOVE ART LU m O or 0 a LU m af 0 oc STAIRCASE w CD --� a 0 0 NSKYLIGHTI �r _ L 0 'v <V 1 BATH 1 F.F. 25.50' i tile BOOK CASE / DISPLAY WALL STUDY F.Fh25.5Q ROOFABOVE LINEN J W �0 m I I I L = 44.60' I I 1 1 2'-6" MAX ALLOW. I r ALLEY -o Ir w m I ,a i A5.0 A m N 1 I I I 1 1 7'-4" 1 NOTE; RADIANT HEATED FLOORS THROUGHOUT IAC I HEAT PREP, FOR FUTURE 1 LEGEND 1 'f NEW STUD WALL I � 1 NEW CONC. WALL 1 I architecture 1075 N. COAST HIGHWAY LAGUNA BEACH, CA 92651 TEL: 949.715.2365 FAX: 949.715.2574 E: CARLTON@GRAHAMARCHITECTURE.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO GRAHAM ARCHITECTURE AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF GRAHAM ARCHITECTURE ISSUE: 09.14.2018 REVISION DATE DESCRIPTION SCALE : 1/4" = 1'-0" FLOOR PLAN UPPER FLOOR A-2.1 c d x C d BEACH F.Y.S.B. 7'-6" 0 Cl) 10'-0" F.Y.S.B. 2'-6" L L = 91.88' MATERIAL KEYNOTES ALUM. 18" (,063) ALUMINUM BREAK METAL - KYNAR FINISH sroNE- TO MATCH WINDOWS METAL -1 0.8mm ZINC METAL FASCIA PANELS METAL -2 0.8mm ZINC METAL - STANDING SEAM - BITUTHENE HT OR CARLISLE WIP 300 HT GLASS UNDERLAYMENT METAL -3 1" HIGH 0.8mm ZINC METAL CAP STEEL PRIME AND PAINT STRUCTURAL STEEL - KAL AUTOBODY PAINT CONC: 1 BOARD FORMED CONCRETE WALL - STD. GRAY coNc: z 112" HIGH PRECAST CONC. CAP - COLOR TBD CV Co CO A?�s� 9'-0" G� N 6o6T'P 2'-4" FLAT 'GRAVED 3:12 SLOPE METAL -2 sruC-i SMOOTH STUCCO - INTEGRAL COLOR - DIAMOND PROPERTY LINE oo1 2'-6" LATH MESH - ANTI CRACK ADD MIXTURE sroNE- VEIN CUT SILVER TRAY. TILE VENEER 18" X 36" STACKED BOND STONE-. 3" VEIN CUT SILVER TRAY. TILE VENEER CAP GLASS 2" FRAMELESS GLASS GUARDRAIL - CLEAR - TEMP. WITH 2' X 221-1 STEEL FLATBAR SUPPORTS KAL KALWALL INSULATED TRANSLUCENT PANELS GRAVEL 4 PLY BUILT UP ROOF WITH GRAVEL BALLAST. 20 YR. MIN. CLASS A WD -1 SELECT HEMLOCK WOOD - STAIN PROPERTY LINE oo1 2'-6" -I- ALLEY architecture 1075 N. COAST HIGHWAY LAGUNA BEACH, CA 92651 TEL: 949.715.2365 FAX: 949.715.2574 E: CARLTON@GRAHAMARCHITECTURE.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO GRAHAM ARCHITECTURE AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF GRAHAM ARCHITECTURE Vow co co N G1 V V W ISSUE: 09.14.2018 REVISION DATE DESCRIPTION - ZL - 0 SCALE: 1/4" = 1'-0" ROOF PLAN A-3.0 27 Q Ogg" I I�o• I I V� -I- ALLEY architecture 1075 N. COAST HIGHWAY LAGUNA BEACH, CA 92651 TEL: 949.715.2365 FAX: 949.715.2574 E: CARLTON@GRAHAMARCHITECTURE.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO GRAHAM ARCHITECTURE AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF GRAHAM ARCHITECTURE Vow co co N G1 V V W ISSUE: 09.14.2018 REVISION DATE DESCRIPTION - ZL - 0 SCALE: 1/4" = 1'-0" ROOF PLAN A-3.0 27 4'-0" S.Y.S.B. 4'-0" S.Y.S.B. 1 MATERIAL KEYNOTES ALUM. 16" (,063) ALUMINUM BREAK METAL - KYNAR FINISH TO MATCH WINDOWS METAL -1 0.8mm ZINC METAL FASCIA PANELS METAL -2 0.8mm ZINC METAL - STANDING SEAM - _ BITUTHENE HT OR CARLISLE WIP 300 HT UNDERLAYMENT METAL-& 1" HIGH 0.8mm ZINC METAL CAP STEEL PRIME AND PAINT STRUCTURAL STEEL - AUTOBODY PAINT coNc: i BOARD FORMED CONCRETE WALL - STD. GRAY coNc.-z 12 HIGH PRECAST CONC. CAP - COLOR TBD o sruc-i SMOOTH STUCCO - INTEGRAL COLOR - DIAMOND N LATH MESH -ANTI CRACK ADD MIXTURE nuixi n ELEV. LOT AVG. GRADE STONE- VEIN CUT SILVER TRAY. TILE VENEER 18" X 36" STACKED BOND STONE- 3" VEIN CUT SILVER TRAV. TILE VENEER CAP GLASS z° FRAMELESS GLASS GUARDRAIL - CLEAR - TEMP. WITH 2' X 212" STEEL FLATBAR SUPPORTS KAL KALWALL INSULATED TRANSLUCENT PANELS GRAVEL 4 PLY BUILT UP ROOF WITH GRAVEL BALLAST. 20 YR. MIN. CLASS A SELECT HEMLOCK WOOD - STAIN L 10'-0" 10' FRONT YARD SETBACK 0 v N 4 N +14.14') LOTAVG. GRADE architecture 1075 N. COAST HIGHWAY LAGUNA BEACH, CA 92651 TEL: 949.715.2365 FAX: 949.715.2574 E: CARLTON@GRAHAMARCHITECTURE.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO GRAHAM ARCHITECTURE AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF GRAHAM ARCHITECTURE t'om 'W W N ♦w V t ,�w V W ca Fftft cc O LOL �w O Z V O v♦ LQ cd (40 tftm N ISSUE: 10.09.2018 REVISION DATE DESCRIPTION SCALE: 114" =1'-0" EXTERIOR ELEVATIONS Am4mO 2q MATERIAL KEYNOTES ALUM. 16" (,063) ALUMINUM BREAK METAL - KYNAR FINISH TO MATCH WINDOWS METAL -1 0.8mm ZINC METAL FASCIA PANELS METAL -2 0.8mm ZINC METAL - STANDING SEAM - BITUTHENE HT OR CARLISLE WIP 300 HT UNDERLAYMENT METAL-& 1" HIGH 0.8mm ZINC METAL CAP STEEL PRIME AND PAINT STRUCTURAL STEEL - AUTOBODY PAINT coNc: i BOARD FORMED CONCRETE WALL - STD. GRAY coNc.-z 12 HIGH PRECAST CONC. CAP - COLOR TBD srK SMOOTH STUCCO - INTEGRAL COLOR - DIAMOND LATH MESH -ANTI CRACK ADD MIXTURE STONE- VEIN CUT SILVER TRAY. TILE VENEER 18" X 36" STACKED BOND STONE- 3" VEIN CUT SILVER TRAV. TILE VENEER CAP GLASS z° FRAMELESS GLASS GUARDRAIL - CLEAR - TEMP. WITH 2' X 212" STEEL FLATBAR SUPPORTS KAL KALWALL INSULATED TRANSLUCENT PANELS GRAVEL 4 PLY BUILT UP ROOF WITH GRAVEL BALLAST. 20 YR. MIN. CLASS A SELECT HEMLOCK WOOD - STAIN +14.14') LOT AVG. GRADE SOUTH ELEV. 701.01. 4 r 10' FRONT YARD SETBACK (+43.14') MAX. BUILDING HEIGHT - PITCHED ROOF MAX. BUILDING HEIGHT - FLAT ROOF (+35.50') UPPER LEVEL PLATE HT. ,(+25.50) T UPPER LEVEL F.F. ALLEY ,(+14.00') T LOWER LEVEL F.F. QST ELEV _. . 4.14') LOT AVG. GRADE architecture 1075 N. COAST HIGHWAY LAGUNA BEACH, CA 92651 TEL: 949.715.2365 FAX: 949.715.2574 E: CARLTON@GRAHAMARCHITECTURE.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO GRAHAM ARCHITECTURE AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF GRAHAM ARCHITECTURE 5 J ISSUE: 10.09.2018 REVISION DATE ❑0 AM A - t'om cW v N ♦w V �w O LL z W V O C LU 00 ' W tmft N DESCRIPTION SCALE: 114" =1'-0" EXTERIOR ELEVATIONS A-4.1 M� i (+43.14') 1 10,-0" � � East Section 10' FRONT YARD SETBACK l i (E.) 6' BLOCK WALL 4'-0" S.Y.S.B. (+43.14') MAX. BUILDING HEIGHT - PITCHED ROOF +38.14') MAX. BUILDING HEIGHT - FLAT ROOF MATERIAL KEYNOTES ALUM. 1'6 (,063) ALUMINUM BREAK METAL - KYNAR FINISH TO MATCH WINDOWS METAL -1 0.8mm ZINC METAL FASCIA PANELS METAL- 0.8mm ZINC METAL - STANDING SEAM - BITUTHENE HT OR CARLISLE WIP 300 HT UNDERLAYMENT NIETAL-3 1" HIGH 0.8mm ZINC METAL CAP STEEL PRIME AND PAINT STRUCTURAL STEEL - AUTOBODY PAINT coNc.-i BOARD FORMED CONCRETE WALL - STD. GRAY coNc: 2 1 21' HIGH PRECAST CONC. CAP - COLOR TBD sruc-1 SMOOTH STUCCO - INTEGRAL COLOR - DIAMOND LATH MESH - ANTI CRACK ADD MIXTURE STONE- VEIN CUT SILVER TRAV. TILE VENEER 18" X 36" STACKED BOND 21'. 6" (+35.501) UPPER LEVEL PLATE HT. sroNE- 3" VEIN CUT SILVER TRAV. TILE VENEER CAP GLASS Z' FRAMELESS GLASS GUARDRAIL - CLEAR - TEMP. WITH Z' X 2 z' STEEL FLATBAR SUPPORTS 0 11'.6"j4(+25.501) N UPPER LEVEL F.F. (N.) 6' HIGH BLOCK WALL 0' - 0" (+14.00') (+14.14') LOWER LEVEL F.F. LOT AVG. GRADE 2 North Section S.Y.S.B. )T AVG. GRADE re 1075 N. COAST HIGHWAY LAGUNA BEACH, CA 92651 TEL: 949.715.2365 FAX: 949.715.2574 E: CARLTON@GRAHAMARCHITECTURE.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO GRAHAM ARCHITECTURE AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF GRAHAM ARCHITECTURE W W KAL KALWALL INSULATED TRANSLUCENT PANELS ISSUE: 10.09.2018 N Z V W m F- O W Z uj V O GRAVEL 4 PLY BUILT UP ROOF WITH GRAVEL REVISION DATE DESCRIPTION BALLAST. 20 YR. MIN. CLASS A wDD SELECT HEMLOCK WOOD - STAIN 2 0 SCALE: 114" = 1'-0" SECTIONS EAST AND NORTH A-5.0 .--�J (N.) 6' BLOCK WALL (N.) 6' BLOCK WALL I S.Y.S.B. LOWER LEVEL F.F. LOT AVG. GRADE MATERIAL KEYNOTES South S e ct i o n A ALUM. 1-16" (.063) ALUMINUM BREAK METAL - KYNAR FINISH TO MATCH WINDOWS J 1 METAL -1 0.8mm ZINC METAL FASCIA PANELS I S.Y.S.B. LOT AVG. GRADE South Section B METAL- 0.8mm ZINC METAL - STANDING SEAM - BITUTHENE HT OR CARLISLE WIP 300 HT UNDERLAYMENT METAL- 1" HIGH 0.8mm ZINC METAL CAP STEEL PRIME AND PAINT STRUCTURAL STEEL - AUTOBODY PAINT CONC-1 BOARD FORMED CONCRETE WALL - STD. GRAY CONC: 2 1 z' HIGH PRECAST CONC. CAP - COLOR TBD STUC-1 SMOOTH STUCCO - INTEGRAL COLOR - DIAMOND LATH MESH -ANTI CRACK ADD MIXTURE sroNE- VEIN CUT SILVER TRAV. TILE VENEER 18" X 36" STACKED BOND sroNE- 3" VEIN CUT SILVER TRAY. TILE VENEER CAP GLAss "FRAMELESS GLASS GUARDRAIL - CLEAR - TEMP. WITH 2' X 2 2' STEEL FLATBAR SUPPORTS KAL KALWALL INSULATED TRANSLUCENT PANELS GRAVEL 4 PLY BUILT UP ROOF WITH GRAVEL BALLAST. 20 YR. MIN. CLASS A wD-1 SELECT HEMLOCK WOOD - STAIN re 1075 N. COAST HIGHWAY LAGUNA BEACH, CA 92651 TEL: 949.715.2365 FAX: 949.715.2574 E: CARLTON@GRAHAMARCHITECTURE.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO GRAHAM ARCHITECTURE AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF GRAHAM ARCHITECTURE W W ISSUE: 09.14.2018 N ♦ ♦w V Z V W m F- O W Z Z oct uj V O r^ uj COOW Vmft N REVISION DATE DESCRIPTION A 0 SCALE: 114" = 1'-0" SECTIONS SOUTH A / B A-5.1 �1 MASTER BATH 10'-0" CLG. GYP. MASTER BEDROOM 10'-0" CLG. 10'-0" CLG. STUC-2 GYP. IF T 9'-0" CLG. GVP. STOR. 9'-0" CLG. GYP. type x CHANGING C s' -o° CLG. ROOM FF I GYP. 9'-0" CLG. GVP. 1I ELEV. I HALL 10'-0" CLG. GYP. FPOWER I � PLAT W.I.C. LAUNDRY GYM F 9'-0" CLG. 9'-0" CLG. 10'-0" CLG. GYP. � GYP. � 11'-0" CLG. — GYP.77 1 NORDIC TRACK I L 11 W.I.C. 9'-0" CLG. GYP_ ELEC. 9'-6" CLG. GYP. type x F -IF- -1 II L --JL ENTRY 10'-0"CLG. FOYER 10'-0" CLG. GYP. 9'-6" CLG. GYP. type x I I I I I I I I I I I I I I I I I I I I I I I 1-_I_LLL1 21'-6" CLG. I I I I I I I I I I I I I I I I I I I I I I 1 I I I I I I I I I I I GARAGE 10'-6" CLG. GYP. type x J_I_L1�_I_LL1____J I I I I I I 10'-6" CLG. DRIVEWAY STUG2 I I I I I I9�'-6" CFGSTOF. I TAS H� STUC-2 u 1 n AL — — — — J MATERIAL KEYNOTES w0 -z 1 X 6 T & G CLEAR SELECT HEMLOCK - STAIN STUC-2 8" STUCCO - SMOOTH - PAINT GYP. '"GYPSUM BOARD - SMOOTH - LEVEL 5 - PAINT STEEL PRIME AND PAINT STRUCTURAL STEEL - AUTOBODY PAINT LEGEND NEW STUD WALL O 2 NEW CONC. WALL I rchitecture COAST HIGHWAY A BEACH, CA 92651 TEL: 949.715.2365 FAX: 949.715.2574 E: CARLTON@GRAHAMARCHITECTURE.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO GRAHAM ARCHITECTURE AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF GRAHAM ARCHITECTURE Vow (40 N 0 s•. CQ V ♦X V Uj W cc FWAMM cc Uj O LAL hUl,-j V r� cc (40VwftN ISSUE: 09.14.2018 REVISION DATE DESCRIPTION - ZL - 0 SCALE : 1/4" = 1'-0" RCP LOWER FLOOR Am6mO STEEL MATERIAL KEYNOTES WD -z 1 X 6 T & G CLEAR SELECT HEMLOCK - STAIN sr 8" STUCCO - SMOOTH - PAINT GYP. 8" GYPSUM BOARD - SMOOTH - LEVEL 5 - PAINT STEEL PRIME AND PAINT STRUCTURAL STEEL - AUTOBODY PAINT — I I I I I I I I I I I I I I 1 I I I — J LEGEND NEW STUD WALL O NEW CONC. WALL I rchitecture COAST HIGHWAY A BEACH, CA 92651 TEL: 949.715.2365 FAX: 949.715.2574 E: CARLTON@GRAHAMARCHITECTURE.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO GRAHAM ARCHITECTURE AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF GRAHAM ARCHITECTURE Vow (40 (410 N 0 s. Q X 0 OIZZ Uj cc FWAMM cc Uj Uj O LAL hUl,-j r r� cc (40VwftN ISSUE: 09.14.2018 REVISION DATE DESCRIPTION - ZL - SCALE : 1/4" = 1'-0" RCP UPPER FLOOR Am6ml �- z --------------------------------------------- E J I WD 2 ------- FxT xT-II I X-1 oo I 'L j `L 71E PANTRY] WIC KITCHEN -0" CLG. GYP. 9'-0" CLG. a 10'-0" CLG. 1\ I I I I I GYP. G S YLI H T \ 10'-0" CLG. I I I I ELEV. TT I TTT-1 I TT PWDR 9'-0"CLG. 10'-0" CLG. GYP. type AL BEDROOM 2 10'-0" CLG. - L I I SkYLIGHt I Ll GYP. J Ll GYP II L1J-I-L1 I -I_LLL= -J GALLERY 10'-0" CLG. PULL DN. STAIR SKYLIGHT us FOR ROOF SERVICE PERSONNEL ONLY F [[I DINING :111GYP. SK IGHT 9'-0" CLG. � 1 9'-0°CLG. - __jBATH v �/ V 9'_0"CLG. 3:12 SLOPE WD -2 (FIR / 1 I� \ , I�I GYP. j I J / BEDROOM 1 STUDY _ 10'-0" CLG. 3:12 SLOPELEI WD -2 LL I I OPENITO ABOVE \ \ \ \ LIVING T rtiGH�ki_CET \ II F 1 _ Iz I,_� 0 GYP GYP. I� I W0 2 I IIHIr I II II I I � I MATERIAL KEYNOTES WD -z 1 X 6 T & G CLEAR SELECT HEMLOCK - STAIN sr 8" STUCCO - SMOOTH - PAINT GYP. 8" GYPSUM BOARD - SMOOTH - LEVEL 5 - PAINT STEEL PRIME AND PAINT STRUCTURAL STEEL - AUTOBODY PAINT — I I I I I I I I I I I I I I 1 I I I — J LEGEND NEW STUD WALL O NEW CONC. WALL I rchitecture COAST HIGHWAY A BEACH, CA 92651 TEL: 949.715.2365 FAX: 949.715.2574 E: CARLTON@GRAHAMARCHITECTURE.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO GRAHAM ARCHITECTURE AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF GRAHAM ARCHITECTURE Vow (40 (410 N 0 s. Q X 0 OIZZ Uj cc FWAMM cc Uj Uj O LAL hUl,-j r r� cc (40VwftN ISSUE: 09.14.2018 REVISION DATE DESCRIPTION - ZL - SCALE : 1/4" = 1'-0" RCP UPPER FLOOR Am6ml �- z AREA CALCULATIONS TOTAL LOWER LEVEL HAB. = 1,722.0 TOTAL UPPER LEVEL HAB. = 2,012.5 12'- 6 1/2" X 30' - 0" 376.3 TOTAL HABITABLE = 3,734.5 TOTAL MECH. / ELEC. = 101.4 TOTAL GARAGE = 447.2 TOTALSTORAGE = 122.4 TOTAL DECK / PATIO = 636.6 PROPOSED LOWER LEVEL 5' - 111/2" X 11' -1" LETTER DIMENSIONS (W X H) AREA (SF) HABITABLE 1 12'- 6 1/2" X 30' - 0" 376.3 6 6'-41/2"X1'-3" 8.0 7 2'-6"X5'-31/2" 13.2 8 9'-61/2"X4'-8" 44.5 9 9'-91/2"X23'-101/2" 233.8 13 18'-0"X11'-1" 199.5 15 24'- 0" X 34'- 6" 828.0 16A 6'-3"X3'-0" 18.8 TOTAL HABITABLE LOWER GARAGE 1 10 120'- 3" X 21'- 4 1/2" 1 432.8 12 3'-6"X4'-11/2" 14.4 TOTAL GARAGE LOWER 447.2 MECH. / ELEC. TOTAL MECH / ELEC LOWER 14 5' - 111/2" X 11' -1" 66.0 4 6'-3"X5'-8" 35.4 STORAGE 11 3' - 6" X 17' - 3" 2 3'-8"X7'-11" 3 2'-8"X2'-71/2" 5 6'-41/2"X4'-1" TOTAL STORAGE LOWER 29.0 7.0 26.0 LEGEND HABITABLE AREA MECHANICAL AREA DECK AREA GARAGE -I- Iarchitecture 1075 N. COAST HIGHWAY LAGUNA BEACH, CA 92651 TEL: 949.715.2365 FAX: 949.715.2574 E: CARLTON@GRAHAMARCHITECTURE.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO GRAHAM ARCHITECTURE AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF GRAHAM ARCHITECTURE Vow (40 N Uj0 s. Q X 0 OIZZ Uj cc FWAMM cc CL k Up r 0 LL CCZ hUl,-j v Cn cc (40VwftN ISSUE: 10.09.2018 REVISION DATE DESCRIPTION ZL - 0 SCALE : 1/4" = 1'-0" AREA CALCS LOWER FLOOR PROPOSED UPPER LEVEL LETTER DIMENSIONS (W X H) AREA (SF) HABITABLE 17 12' - 6 1/2" X 5' - 0" 62.7 19 36'- 6" X 20'- 0" 730.0 20 17'- 5 1/2" X 5'- 0" 87.3 21 6'-4"X25'-0" 158.3 22 3'-0"X2'-10" 8.5 23 6'-3"X19'-4" 120.8 24 4' - 11" X 25'- 0" 122.9 25 5' - 3 1/2" X 22' -3" 117.7 26 19'- 1" X 31'- 8" 604.3 TOTAL HABITABLE UPPER 2,012.5 DECK/ PATIO 16 B 12' - 6 1/2" X 3' - 5" 42.9 18 23' - 101/2" x 8'- 5" 200.9 27 19'- 1" x 20'- 7" 392.8 TOTAL DECK UPPER 636.6 LEGEND HABITABLE AREA MECHANICAL AREA DECK AREA GARAGE -I- Iarchitecture 1075 N. COAST HIGHWAY LAGUNA BEACH, CA 92651 TEL: 949.715.2365 FAX: 949.715.2574 E: CARLTON@GRAHAMARCHITECTURE.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO GRAHAM ARCHITECTURE AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF GRAHAM ARCHITECTURE Vow (40 N Uj0 s. Q X 0 OIZZ Uj cc FWAMM cc CL k Up r 0 LL CCZ hUl,-j v Cn cc (40VwftN ISSUE: 10.09.2018 REVISION DATE DESCRIPTION ZL - 0 SCALE : 1/4" = 1'-0" AREA CALCS LOWER FLOOR 20 L COUNTED BELOW HIGH ART 21 _ z / 23 19 C> TV ABOVE AREA CALCULATIONS TOTAL LOWER LEVEL HAB. = 1,722.0 TOTAL UPPER LEVEL HAB. = 2,012.5 12'- 6 1/2" X 30' - 0" 376.3 TOTAL HABITABLE = 3,734.5 TOTAL MECH. / ELEC. = 101.4 TOTAL GARAGE = 447.2 TOTALSTORAGE = 122.4 TOTAL DECK/ PATIO = 636.6 24 m c� m m I SCULPTURE ART TV 22 SKNOGHT a aJ PROPOSED LOWER LEVEL 5' - 111/2" X 11' -1" LETTER DIMENSIONS (W X H) AREA (SF) HABITABLE 1 12'- 6 1/2" X 30' - 0" 376.3 6 6'-41/2"X1'-3" 8.0 7 2'-6"X5'-31/2" 13.2 8 9'-61/2"X4'-8" 44.5 9 9'-91/2"X23'-101/2" 233.8 13 18'-0"X11'-1" 199.5 15 24'- 0" X 34'- 6" 828.0 16A 6'-3"X3'-0" 18.8 TOTAL HABITABLE LOWER 1,722.0 GARAGE 1 10 20' - 3" X 21' - 4 1/2" 432.8 12 3'-6"X4'-11/2" 14.4 TOTAL GARAGE LOWER 447.2 MECH. / ELEC. TOTAL MECH / ELEC LOWER STORAGE TOTAL STORAGE LOWER 14 5' - 111/2" X 11' -1" 66.0 4 6'-3"X5'-8" 35.4 11 3'-6"X17'-3" 60.4 2 3'-8"X7'-11" 29.0 3 2'-8"X2'-71/2" 7.0 5 6'-41/2"X4'-1" 26.0 MOTORIZED 26 ART w CD a 25 o N z w COUNTED BELOW I I I I I I Us I T 1 \ 1 I \ I I BOOK CASE/ DISPLAY WALL I Z ELY so m m I m m �� m I I I I I I I 1 I 1 1 I LEGEND HABITABLE AREA MECHANICAL AREA DECK AREA GARAGE (?2 architecture 1075 N. COAST HIGHWAY LAGUNA BEACH, CA 92651 TEL: 949.715.2365 FAX: 949.715.2574 E: CARLTON@GRAHAMARCHITECTURE.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO GRAHAM ARCHITECTURE AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF GRAHAM ARCHITECTURE Vow (40 N Uj0 s. Q X 0 OIZZ Uj cc M� CL k O LL CC hum' -j Cn cc (40VwftN ISSUE: 10.09.2018 REVISION DATE DESCRIPTION ZL - 0 SCALE : 1/4" = 1'-0" AREA CALCS UPPER FLOOR Am7ml 35 PROPOSED UPPER LEVEL LETTER DIMENSIONS (W X H) AREA (SF) HABITABLE 17 12' - 6 1/2" X 5' - 0" 62.7 19 36'- 6" X 20'- 0" 730.0 20 17'- 5 1/2" X 5'- 0" 87.3 21 6'-4"X25'-0" 158.3 22 3'-0"X2'-10" 8.5 23 6'-3"X19'-4" 120.8 24 4'- 11" X 25'- 0" 122.9 25 5' - 3 1/2" X 22'-3" 117.7 26 19'- 1" X 31'- 8" 604.3 TOTAL HABITABLE UPPER 2,012.5 DECK/ PATIO 16 B 12'- 6 1/2" X 3'- 5" 42.9 18 23'- 101/2" x 8' - 5" 200.9 27 19'- 1" x 20'- 7" 392.8 TOTAL DECK UPPER 636.6 I I I I I I I 1 I 1 1 I LEGEND HABITABLE AREA MECHANICAL AREA DECK AREA GARAGE (?2 architecture 1075 N. COAST HIGHWAY LAGUNA BEACH, CA 92651 TEL: 949.715.2365 FAX: 949.715.2574 E: CARLTON@GRAHAMARCHITECTURE.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO GRAHAM ARCHITECTURE AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF GRAHAM ARCHITECTURE Vow (40 N Uj0 s. Q X 0 OIZZ Uj cc M� CL k O LL CC hum' -j Cn cc (40VwftN ISSUE: 10.09.2018 REVISION DATE DESCRIPTION ZL - 0 SCALE : 1/4" = 1'-0" AREA CALCS UPPER FLOOR Am7ml 35 2 3 4 1 51 Rz v v `n v O -,A rn u H 1 r L7 C I D II x BLOCK E LOT 17 til o' O a c,l c..1 ry Iv ti ti L.a N !v c., (o a O c„ L0 c.., rn n o o rn 0v o Z Z Z 2 2 Z 2 Iw toxo 00 `o, v o�����o�� 0000000 7� � o= x T o \ooZzzx2Zx )�8 T o INLET-®- SHOWER TO o = 0 0 0 0 0 6;/NC <f3 - I BE_CONNECTED'- �� L r - - -I }JTO SEWER�SYS. 19 50) TW + 5.78) +(15.82) (1N. os)4i'ss" E (5.91) + \-- (15.72) -r(/,MIN I I �} 1.'p7� I_. -`S �' /4 t.,p rfLL/ Oj 1�'/„F?, ' __� SHOWER / 14 3 p \ °' m I .� E I v rn D rn ti I + l0 M u H 1 r L7 C I D II x BLOCK E LOT 17 til o' O a c,l c..1 ry Iv ti ti L.a N !v c., (o a O c„ L0 c.., rn n o o rn 0v o Z Z Z 2 2 Z 2 Iw toxo 00 `o, v o�����o�� 0000000 7� � o= x T o \ooZzzx2Zx )�8 T o INLET-®- SHOWER TO o = 0 0 0 0 0 6;/NC <f3 - I BE_CONNECTED'- �� L r - - -I }JTO SEWER�SYS. 19 50) TW + 5.78) +(15.82) (1N. os)4i'ss" E (5.91) + \-- (15.72) -r(/,MIN I I �} 1.'p7� I_. -`S �' /4 t.,p rfLL/ Oj 1�'/„F?, ' __� SHOWER / 14 3 p \ °' m I .� E _ o n \ n o n n x I to �_.:. rG all m oti NV c o o v N v _ CO FS:; : a 21fi8'R E, �OGEAN FR0 T - - - L .. ((' POR, T BEACH, C. VvoL�' NEW L\OT "� n w �ti 1371 eRL o v. v PROP. RESIDENCE '= ti o M GAR/GFAR?A� c F.F.=14.00 w 1i o 138/ r `m �I l a o c Z z m m l \( J to Il I'ri``I[I;wd:..,a (� O n O cn cq LL. P-AD=XX.XX 0 0 2 2 p ti = GARAGE DOOR .76 _ :A, o = !lv o = oBUILDING FOOTPRINT\, Z o o n GARAGE DL - -@9-DS o o - rr -- I:. TYP. TG ,... I MECHANICAL 1 INV. -7�' v 0 '7pVo F -L -N -095f w + (13d5)� °'' 34 + /tT30)1 1.2.1.Q I 3.20,1 v 4 13.86 TG ^ �� ) - - - - (133') EX+WALL'TO�� INV:v/ 3H(1331) -+(1324) _ o 12:30 INV �� REMAIN N.,1111 o I v oPO o o v ov ov oo � I Ivy �w ti�CCO 0) �. w �. �. � \o= 22 2Z o 22 2Z 2222= I xo I 'I o0 0o i o0 00 0000 Io m wICD0 o il< IC) 11� I� CVo CONCRETE CURB. o SIDEWALK. 0 1 i 0 LL CONCRETE TRENCH DRAIN. (SHOWN) PAVEMENT. 1 ( ° f OUTLET. RUBBER GASKET EARTH. MATERIAL. OUTLET ADAPTOR & BYPASS WEIR. REMOVABLE CAP \ \\ / / FILTER ELEMENT SHEATHED IN GEOTEXTILE FOR PERIODIC / /% / SLEEVE. MAINTENANCE. : o FOSSIL ROCKTM ABSORBENT POUCHES. DETAIL NOTES: IS TRENCH DRAIN FILTER 1. Filter insert shall have a high flow bypass feature. 2. Filter outlet adapter shall be constructed from stainless steel Type 304. Alternate outlet adaptor for shallow installations shall be PVC SCH-40. See detail B, sheet 2 of 2. 3. Filter medium shall be Fossil Rock rm, installed and maintained in accordance with manufacturer specifications. 4. Storage capacity reflects 80% of maximum solids collection prior to impeding filtering bypass. 5. For alternate outlet adapter configurations used for extremely shallow trench drains contact Oldcastle Stormwater Solutions for engineering assistance. 6. Filter element should be a minimum of one half the length of trench. Confirm flow rate upon order. ® RoGard®IL41 Ndcastle° Stormwater Solutions Catch Basin Insert Filter 79218outhpark Plaza, Suite 2001 Littleton, CO 1801201 Ph: 800.579.8819 1 oldcastlestonnwater.com THISOCCUMENTIS mEPROPER"FOLOCJWLEPRECAST,INC. ITIS SUBMUTED FOR REFERENCE PURPOSES ONLY ANO SHALL NOT BE USED IN ANY WAY INJURIOUS TO THE INTERESTS OF SAID COMPANY. COPYRIGK020100WCASTLE PRECAST. INC. ALL RIGHTS RESERVED, Inlet Trench Drain Style DRAWING N0. REV ECO ECO -0142 OA,E Filtration FG -LP -0002 H JP 7 13 16 JPR 2/21/07 SHEET 1 OF 2 A IB I v rn D � ti I r, l0 M N til ti o N w CIO N `moo =w Iv x LOT 19 o LAND SURVEYING O O � O 1 3 9 Avenida Navarro o r (D -CONNECT DOWNSPOUT TO STORM DRAIN SYSTEM PER DETAIL HEREON. A o cn Iv o SCOPE OF WORK ICDI Z Z s 1i1�2.45 DEMOLITION OF EXISTING RESIDENCE AND CONSTRUCTION OF NEW CUSTOM RESIDENCE, TOGETHER WITH _ o n \ n o n n x I to �_.:. rG all m oti NV c o o v N v _ CO FS:; : a 21fi8'R E, �OGEAN FR0 T - - - L .. ((' POR, T BEACH, C. VvoL�' NEW L\OT "� n w �ti 1371 eRL o v. v PROP. RESIDENCE '= ti o M GAR/GFAR?A� c F.F.=14.00 w 1i o 138/ r `m �I l a o c Z z m m l \( J to Il I'ri``I[I;wd:..,a (� O n O cn cq LL. P-AD=XX.XX 0 0 2 2 p ti = GARAGE DOOR .76 _ :A, o = !lv o = oBUILDING FOOTPRINT\, Z o o n GARAGE DL - -@9-DS o o - rr -- I:. TYP. TG ,... I MECHANICAL 1 INV. -7�' v 0 '7pVo F -L -N -095f w + (13d5)� °'' 34 + /tT30)1 1.2.1.Q I 3.20,1 v 4 13.86 TG ^ �� ) - - - - (133') EX+WALL'TO�� INV:v/ 3H(1331) -+(1324) _ o 12:30 INV �� REMAIN N.,1111 o I v oPO o o v ov ov oo � I Ivy �w ti�CCO 0) �. w �. �. � \o= 22 2Z o 22 2Z 2222= I xo I 'I o0 0o i o0 00 0000 Io m wICD0 o il< IC) 11� I� CVo CONCRETE CURB. o SIDEWALK. 0 1 i 0 LL CONCRETE TRENCH DRAIN. (SHOWN) PAVEMENT. 1 ( ° f OUTLET. RUBBER GASKET EARTH. MATERIAL. OUTLET ADAPTOR & BYPASS WEIR. REMOVABLE CAP \ \\ / / FILTER ELEMENT SHEATHED IN GEOTEXTILE FOR PERIODIC / /% / SLEEVE. MAINTENANCE. : o FOSSIL ROCKTM ABSORBENT POUCHES. DETAIL NOTES: IS TRENCH DRAIN FILTER 1. Filter insert shall have a high flow bypass feature. 2. Filter outlet adapter shall be constructed from stainless steel Type 304. Alternate outlet adaptor for shallow installations shall be PVC SCH-40. See detail B, sheet 2 of 2. 3. Filter medium shall be Fossil Rock rm, installed and maintained in accordance with manufacturer specifications. 4. Storage capacity reflects 80% of maximum solids collection prior to impeding filtering bypass. 5. For alternate outlet adapter configurations used for extremely shallow trench drains contact Oldcastle Stormwater Solutions for engineering assistance. 6. Filter element should be a minimum of one half the length of trench. Confirm flow rate upon order. ® RoGard®IL41 Ndcastle° Stormwater Solutions Catch Basin Insert Filter 79218outhpark Plaza, Suite 2001 Littleton, CO 1801201 Ph: 800.579.8819 1 oldcastlestonnwater.com THISOCCUMENTIS mEPROPER"FOLOCJWLEPRECAST,INC. ITIS SUBMUTED FOR REFERENCE PURPOSES ONLY ANO SHALL NOT BE USED IN ANY WAY INJURIOUS TO THE INTERESTS OF SAID COMPANY. COPYRIGK020100WCASTLE PRECAST. INC. ALL RIGHTS RESERVED, Inlet Trench Drain Style DRAWING N0. REV ECO ECO -0142 OA,E Filtration FG -LP -0002 H JP 7 13 16 JPR 2/21/07 SHEET 1 OF 2 A IB R Ci LEGEND HARDSCAPE F_ -1 INFILTRATION TRENCH L--- I --100-- CONTOUR (EXISTING) -100 - CONTOUR (PROPOSED) 100.00 SPOT ELEVATION (PROPOSED) 100.00 SPOT ELEVATION (MATCH EXISTING) ==4"== PROPOSED DRAIN LINE --SUB-- PROPOSED FORCE MAIN LINE FM PROPOSED FORCE MAIN LINE PROPOSED SCREEN WALL A SECTION LETTER 10 SHEET NUMBER • DS DOWNSPOUT FF FINISH FLOOR FG FINISH GRADE FL OR FL FLOW LINE FS FINISH SURFACE GFF GARAGE FINISH FLOOR INV INVERT P.L. OR R PROPERTY LINE PA PLANTER AREA TC TOP OF CURB TF TOP OF FOOTING TG TOP OF GRATE TP TOP OF PILASTER TW TOP OF WALL C I CONSTRUCTION NOTES 1 D � ti I r, l0 M N til ti a N w INSTALL 6" ATRIUM DRAIN NDS TYPE 90 W/ RISER & ADAPTOR OR EQUAL. SEE DETAIL ON SHEET C-4. Cn Iv x LOT 19 o LAND SURVEYING I„ m V N I I O 1 3 9 Avenida Navarro � ' (D -CONNECT DOWNSPOUT TO STORM DRAIN SYSTEM PER DETAIL HEREON. A o cn Iv I. N SCOPE OF WORK ICDI Z Z R Ci LEGEND HARDSCAPE F_ -1 INFILTRATION TRENCH L--- I --100-- CONTOUR (EXISTING) -100 - CONTOUR (PROPOSED) 100.00 SPOT ELEVATION (PROPOSED) 100.00 SPOT ELEVATION (MATCH EXISTING) ==4"== PROPOSED DRAIN LINE --SUB-- PROPOSED FORCE MAIN LINE FM PROPOSED FORCE MAIN LINE PROPOSED SCREEN WALL A SECTION LETTER 10 SHEET NUMBER • DS DOWNSPOUT FF FINISH FLOOR FG FINISH GRADE FL OR FL FLOW LINE FS FINISH SURFACE GFF GARAGE FINISH FLOOR INV INVERT P.L. OR R PROPERTY LINE PA PLANTER AREA TC TOP OF CURB TF TOP OF FOOTING TG TOP OF GRATE TP TOP OF PILASTER TW TOP OF WALL C F G H I CONSTRUCTION NOTES 1 D � ti I r, c., N til ti a N w INSTALL 6" ATRIUM DRAIN NDS TYPE 90 W/ RISER & ADAPTOR OR EQUAL. SEE DETAIL ON SHEET C-4. Cn Iv x o LAND SURVEYING I„ m V N I I O F G H oo, p C ;PROP.T ; r P 112.-39 TG 30 co II I 11 rn (' rn � I L, 10.80 INVr� 1 1 r o I I r �- I 13 0 FS FSll6 II � �� 4 . OCL � fo c., L ->P1, �': I 12.35 TG o I�I - I 1235 : MO n I I 11 50 12.33 -TG _ i" m INV. 0 10"I -W I m 11.251NV, 11 � a 1LTER INSERT 0.90,IV.IN�INF. I a C, 1,13 ��01I o mol � a r 2 - • / � I CONSTRUCTION NOTES 1 D � ti I r, ENGINEERING, INC. N til ti o , INSTALL 6" ATRIUM DRAIN NDS TYPE 90 W/ RISER & ADAPTOR OR EQUAL. SEE DETAIL ON SHEET C-4. Cn Iv x o LAND SURVEYING I„ m V N I I O 1 3 9 Avenida Navarro � ' (D -CONNECT DOWNSPOUT TO STORM DRAIN SYSTEM PER DETAIL HEREON. I TEL (949) 715-2365 www.loalengineering.com Iv I. N SCOPE OF WORK !v ti Jry s 1i1�2.45 DEMOLITION OF EXISTING RESIDENCE AND CONSTRUCTION OF NEW CUSTOM RESIDENCE, TOGETHER WITH QROFESS/�y,, APPURTENANT HARDSCAPE, LANDSCAPE, AND DRAINAGE IMPROVEMENTS. iH 11.45 INV 5 ' No. 57587 70 O 0 8 16 TW Q 'I -SI 1 - SC ALE: 1 "- 8 N I ? oo, p C ;PROP.T ; r P 112.-39 TG 30 co II I 11 rn (' rn � I L, 10.80 INVr� 1 1 r o I I r �- I 13 0 FS FSll6 II � �� 4 . OCL � fo c., L ->P1, �': I 12.35 TG o I�I - I 1235 : MO n I I 11 50 12.33 -TG _ i" m INV. 0 10"I -W I m 11.251NV, 11 � a 1LTER INSERT 0.90,IV.IN�INF. I a C, 1,13 ��01I o mol � a r 2 - • / � PLANS PREPARED BY: CONSTRUCTION NOTES 1 D � j r � m r, ENGINEERING, INC. N til v � o , INSTALL 6" ATRIUM DRAIN NDS TYPE 90 W/ RISER & ADAPTOR OR EQUAL. SEE DETAIL ON SHEET C-4. Cn Iv CIVIL ENGINEERING PREPARED FOR: LAND SURVEYING I„ m V N I I O 1 3 9 Avenida Navarro 2168 EASE OCEAN FRONT, San Clemente, CA 92672 (D -CONNECT DOWNSPOUT TO STORM DRAIN SYSTEM PER DETAIL HEREON. 9 4 9 . 4 9 2 . 8 5 8 6 TEL (949) 715-2365 www.loalengineering.com 10 INSTALL TRENCH DRAIN FILTER. FLOGARD TRENCH DAIN FILTER MODEL FG-TDOF3. ALL WORK RELATED TO WATER IN THE PUBLIC RIGHT-OF-WAY SHALL BE PERFORMED BY A C-34 LICENSED SCOPE OF WORK Z Jry s 1i1�2.45 DEMOLITION OF EXISTING RESIDENCE AND CONSTRUCTION OF NEW CUSTOM RESIDENCE, TOGETHER WITH QROFESS/�y,, APPURTENANT HARDSCAPE, LANDSCAPE, AND DRAINAGE IMPROVEMENTS. iH 11.45 INV 5 ' No. 57587 70 O 0 8 16 TW Q l'IIIJ15.00 - 11111 :l -SI 1 - SC ALE: 1 "- 8 oo, p C ;PROP.T ; r P 112.-39 TG 30 co II I 11 rn (' rn � I L, 10.80 INVr� 1 1 r o I I r �- I 13 0 FS FSll6 II � �� 4 . OCL � fo c., L ->P1, �': I 12.35 TG o I�I - I 1235 : MO n I I 11 50 12.33 -TG _ i" m INV. 0 10"I -W I m 11.251NV, 11 � a 1LTER INSERT 0.90,IV.IN�INF. I a C, 1,13 ��01I o mol � a r 2 - • / � PLANS PREPARED BY: CONSTRUCTION NOTES 1 D � j r � m rn ~ ENGINEERING, INC. � r r o O INSTALL 6" ATRIUM DRAIN NDS TYPE 90 W/ RISER & ADAPTOR OR EQUAL. SEE DETAIL ON SHEET C-4. O $ DETAIL INFILTRATION TRENCH CRUSHED ROCK T � �.� A PUBLIC WORKS DEPARTMENT ENCROACHMENT PERMIT INSPECTION IS REQUIRED BEFORE THE BUILDING CIVIL I T Q 9��� DEPARTMENT PERMIT FINAL CAN BE ISSUED. AT THE TIME OF PUBLIC WORKS DEPARTMENT INSPECTION, IF lF OF CAt.�FR� ANY OF THE EXISTING PUBLIC IMPROVEMENTS SURROUNDING THE SITE IS DAMAGED, NEW CONCRETE SIDEWALK, PLANS PREPARED BY: CONSTRUCTION NOTES a INFRASTRUCTURE ARE DEEMED SUBSTANDARD, A NEW 1 -INCH WATER SERVICE, WATER METER BOX, SEWER T_ CONCRETE HARDSCAPE. TOAL O2 -CONSTRUCT CONCRETE DRIVEWAY. ENGINEERING, INC. ( -INSTALL 4" DIA. SCHEDULE 40 PVC PIPE DRAIN SYSTEM. (ASTM D1785) M Q- INSTALL 6" DECK DRAIN NDS TYPE 40 W/ RISER & ADAPTOR OR EQUAL. SEE DETAIL ON SHEET C-4. O INSTALL 6" ATRIUM DRAIN NDS TYPE 90 W/ RISER & ADAPTOR OR EQUAL. SEE DETAIL ON SHEET C-4. O 0- INSTALL 8" CHANNEL DRAIN, TRAFFIC RATED, NDS SERIES, TYPE 864 W/ TRAFFIC RATED GRATE OR EQUAL. CIVIL ENGINEERING PREPARED FOR: LAND SURVEYING 7�INSTALL 3" MICRO CHANNEL DRAIN, NDS PRO SERIES, TYPE 764 OR EQUAL. STORMWATER QUALITY 0 -CONSTRUCT INFILTRATION TRENCH, L=18.5'X2'X1' PER CITY OF NEWPORT BEACH STD. SEE DETAIL HEREON. 1 3 9 Avenida Navarro 2168 EASE OCEAN FRONT, San Clemente, CA 92672 (D -CONNECT DOWNSPOUT TO STORM DRAIN SYSTEM PER DETAIL HEREON. 9 4 9 . 4 9 2 . 8 5 8 6 TEL (949) 715-2365 www.loalengineering.com 10 INSTALL TRENCH DRAIN FILTER. FLOGARD TRENCH DAIN FILTER MODEL FG-TDOF3. ALL WORK RELATED TO WATER IN THE PUBLIC RIGHT-OF-WAY SHALL BE PERFORMED BY A C-34 LICENSED SCOPE OF WORK Z W DEMOLITION OF EXISTING RESIDENCE AND CONSTRUCTION OF NEW CUSTOM RESIDENCE, TOGETHER WITH QROFESS/�y,, APPURTENANT HARDSCAPE, LANDSCAPE, AND DRAINAGE IMPROVEMENTS. CITY OF NEWPORT BEACH NOTES No. 57587 70 O T � �.� A PUBLIC WORKS DEPARTMENT ENCROACHMENT PERMIT INSPECTION IS REQUIRED BEFORE THE BUILDING CIVIL I T Q 9��� DEPARTMENT PERMIT FINAL CAN BE ISSUED. AT THE TIME OF PUBLIC WORKS DEPARTMENT INSPECTION, IF lF OF CAt.�FR� ANY OF THE EXISTING PUBLIC IMPROVEMENTS SURROUNDING THE SITE IS DAMAGED, NEW CONCRETE SIDEWALK, NOTICE TO CONTRACTOR REQUIRED CERTIFICATIONS /APPROVALS In addition to any certifications required by the agencies having jurisdiction over this project, the following approvals from the Civil engineer of record are required: 1. Foundation forms for improvements on or abutting property lines is required prior to concrete pour. 2. Location, size, and depth of all drain lines prior to backfill. PRELIMINARY PLAN, NOT FOR CONSTRUCTION D E F IG H w a 0 a w a 0 a: N Z 0 N w CURB AND GUTTER, AND ALLEY/STREET PAVEMENT WILL BE REQUIRED. ADDITIONALLY, IF EXISTING UTILITIES a INFRASTRUCTURE ARE DEEMED SUBSTANDARD, A NEW 1 -INCH WATER SERVICE, WATER METER BOX, SEWER LATERAL AND/OR CLEANOUT WITH BOX AND LID WILL BE REQUIRED. 100% OF THE COST SHALL BE BORNE Z BY THE PROPERTY OWNER (MUNICIPAL CODES 14.24.020 AND 14.08.030). SAID DETERMINATION AND THE CALEB RIOS EXTENT OF THE REPAIR WORK SHALL BE MADE AT THE DISCRETION OF THE PUBLIC WORKS INSPECTOR. R.C.E. 57587 O2 - AN ENCROACHMENT AGREEMENT IS REQUIRED FOR ALL NON-STANDARD IMPROVEMENTS WITHIN THE PUBLIC DATE: RIGHT-OF-WAY. ALL NON-STANDARD IMPROVEMENTS SHALL COMPLY WITH CITY COUNCIL POLICY L-6. O 3� AN APPROVED CITY OF NEWPORT BEACH ENCROACHMENT PERMIT IS REQUIRED FOR ALL WORK ACTIVITIES PREPARED FOR: WITHIN THE PUBLIC RIGHT-OF-WAY. g WEDGE HOUSE O4 -SURVEYOR OR ENGINEER SHALL PERMANENTLY MONUMENT PROPERTY CORNERS OR OFFSETS BEFORE STARTING 2168 EASE OCEAN FRONT, GRADING. NEWPORT BEACH, CA 92661 SURVEYOR TO FILE A CORNER RECORD OR RECORD OF SURVEY WITH THE OFFICE OF THE COUNTY SURVEYOR. TEL (949) 715-2365 EVIDENCE OF FILING SHALL BE SUBMITTED TO BUILDING INSPECTOR PRIOR TO FOUNDATION INSPECTION. ALL WORK RELATED TO WATER IN THE PUBLIC RIGHT-OF-WAY SHALL BE PERFORMED BY A C-34 LICENSED W U Z W PIPELINE CONTRACTOR OR AN "A" LICENSED GENERAL ENGINEERING CONTRACTOR. 000_ O ALL WORK RELATED TO WASTEWATER IN THE PUBLIC RIGHT-OF-WAY SHALL BE PERFORMED BY A C-42 Q O Z J (� LICENSED SANITATION SEWER CONTRACTOR OR AN "A" LICENSED GENERAL ENGINEERING CONTRACTOR. ISSUANCE OF A BUILDING PERMIT BY THE CITY OF NEWPORT BEACH DOES NOT RELEIVE APPLICANTS OF THE z 3 LEGAL REQUIREMENTS TO OBSERVE COVENANTS, CONDITIONS AND RESTRICTIONS WHICH MAY BE RECORDED _ QZ W J U AGAINST THE PROPERTY OR TO OBTAIN PLANS. YOU SHOULD CONTACT YOUR COMMUNITY ASSOCIATIONS PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION AUTHORIZED BY THIS PERMIT. ADDITIONAL NOTES 00 t0 1. ALL ROOFS SHALL BE GUTTERED AND DOWNSPOUTS SHALL CONNECT TO THE STORM DRAIN SYSTEM. N DATE: H. SCALE: 2. PAD ELEVATION BASED ON XX SLAB OVER X GRAVEL PER SOILS REPORTS RECOMMENDATIONS. CONTRACTOR N/A SURVEY DATE: V. SCALE: 4/17/17 N/A DRN.: A.A. DWG. NO. C-01 _O1 f CHO.: C.R. TO VERIFY PAD W/ STRUCTURAL ENGINEER AND SOILS ENGINEER PRIOR TO GRADING. APPD.: C.R. JOB NO. 3. WHEN AN INTERIOR OR EXTERIOR UTILITY TRENCH IS PROPOSED PARALLEL TO A BLDG FOOTING, THE OF 18201 1 1 BOTTOM OF THE TRENCH SHOULD NOT BE LOCATED BELOW A 1:1 PLANE PROJECTED DOWNWARD FROM 3C THE OUTSIDE BOTTOM EDGE OF THE ADJACENT FOOTING. WHERE THIS CONDITION EXISTS, THE ADJACENT FOOTING SHOULD BE DEEPENED SUCH THAT THE BOTTOM OF THE UTILITY TRENCH IS LOCATED ABOVE THE 1:1 PROJECTION. 4. FOR FOOTING AND FOUNDATION DESIGN SEE STRUCTURAL PLANS. 5. ALL RECOMMENDATIONS IN THE PROJECT SOILS REPORT PREPARED BY R MCCARTHY CONSULTING, INC. (DATED AUGUST 4, 2018; J.N. 20180711-1) ARE CONSIDERED A PART OF THESE PLANS. 6. ALL DRAINLINES SHALL HAVE A MIN. POSITIVE SLOPE OF 1% TOWARD OUTLET. NOTICE TO CONTRACTOR REQUIRED CERTIFICATIONS /APPROVALS In addition to any certifications required by the agencies having jurisdiction over this project, the following approvals from the Civil engineer of record are required: 1. Foundation forms for improvements on or abutting property lines is required prior to concrete pour. 2. Location, size, and depth of all drain lines prior to backfill. PRELIMINARY PLAN, NOT FOR CONSTRUCTION D E F IG H w a 0 a w a 0 a: N Z 0 N w a Z O Z g a CD aUa m W U Z W 000_ O Q O Z J (� Z W z 3 _ QZ W J U W 00 t0 N DATE: H. SCALE: 12/12/18 N/A SURVEY DATE: V. SCALE: 4/17/17 N/A DRN.: A.A. DWG. NO. C-01 _O1 f CHO.: C.R. APPD.: C.R. JOB NO. SHEET OF 18201 1 1 3C