Loading...
HomeMy WebLinkAbout16 - Zoning Code and Local Coastal Program Amendments Due to VE Special Flood Hazard Area as Mapped by FEMA - PowerPointMarch 16, 2019 Item No. 16 CITYCOUNCIL March 26, 2019 • Federal Emergency Management Agency (FEMA) • VE Zone =Coastal High Hazard Area • i.% annual chance (base) flood limits (loo -year flood) • Subject to high velocity water, including waves Community Development Department - Planning Division 48th Street Properties Affected by VE Ione Properties Affected by VE Zone (1 66 ) Community Development Department - Planning Division 24th Street L—/ U L --- ■ Use of pilings, columns ■ Lowest structural above the Base (BFE) posts, piers or member at or Flood Elevation ■ BFE in West Newport = 1.5 ft. ■The finished floor elevation must be 1 ft. above the BFE (1.6 ft.) Community Development Department - Planning Division Toward Flood Source 100 -Year Wave Crest Bottom of Lowest Horizontal Elevation (BFE) Structural Member Freeboard 106 -Year Elevation ' I U I I U I I Exceeding NFIP Elevation Requirements in Costal A Zones and 4 Zones ■ Structures must be elevated on an open foundation ■ Space below all new construction must be free of obstructions Community Development Department - Planning Division r— Free- of- Obstruction Requirements for Buildings Located in Coastal High Hazard Areas in accordance with the National Flood Insurance Program Technical Bulletin 5 /August 2008 HM, Height Measurement R `� ALL TIREE SIDES OF COVERED DEOK T.O. RIDGE TA. 29 3F ELEVATOR SNPLL REMAIN OPEN IN PERPE1VITf PND • �q4, bNAPT .4083 TA. RIDbE = A'-0' VT M. LIMIT MAY NOT BE ENGL05®IN IF£MVRE. ` T________ -3--- I I .30.IT Q — `OPEN TOS ® 24'-0' OITY NT. LIMIT _ _ _ _ _ _ _ _ O DEGK/FLAT ROOFS r w 1--------- r u ses O—K J I - FEAIN� TA.SNt'b •. 32.11' I NCOVER®'RAOF OEGK 'qpl Ron YABN!'b • 31.11 TINRD FLOOR 4 ry TA9NT'6. 22.IT' Accessory7*-cceso g Structures Gara e - .,__ - ... GARAGE E5TABLISHED ftAft 000 • �R bRADE • II.BS' N� memo 000 Community Development Department - Planning Division B F E 15' FEMA Compliant Design 33' Community Development Department - Planning Division Existing Grade 12' Existing Design 1W W FEMA Compliant Design 3FE 15' Existing Grade 12' Community Development Department - Planning Division 3, • Zoning Code requires garages • Space below BFE must be free of obstructions • Breakaway wall designs conflict with seismic requirements • Enclosed garages no longer possible • Open carport design alternative Community Development Department - Planning Division FORK NO GARAGE DOOR GLEAR TO LOAEST HORZ. STRUGT. MEMEBER = 16.0' • Measure height from existing grade or finished floor? •Allow raised decks to encroach into setbacks? •Visual quality/aesthetic issues • Privacy issues Community Development Department - Planning Division Stairs Open risers Carport Access • Landing interference with parking spaces • Safety issue if primary entrance Side Access • Landing within setback? • Recess doorway? • Building Code compliance Community Development Department - Planning Division 11 Code Amendment to Address: s. How building heights are measured 2. Allowing carports 3. Accessory structure height measurement/setbacks 4. Primary entrance location/accessibility issues Community Development Department - Planning Division 12 Properties Affected by VE Zane 0 Properties Affected by VE Zone (166 ) 0 Community Development Department - Planning Division (—j Zj Lj-- COP.ST iAYY W 11111 ■IIINI�11111 11,111 IIINi.IIIII I�IN�II�1�IIIIN1 13