HomeMy WebLinkAboutX2018-3655 - Alternative Material & MethodsCITY OF NEWPORT BEACH
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING DIVISION%y
100 Civic Center Drive I P.O. Box 17881 Newport Beach, CA 92658.8915 T
www.nsw,portbeachca.gov 1(949)844-3200
CASE NO.; ®{ ct aa.
® REQUEST FOR MODIFICATION TO PROVISIONS
OF TITLE 9 (FIRE CODE) OR TITLE 15 (BUILDING CODE)
OF THE NEWPORT BEACH MUNICIPAL CODE
(See Reverse for Basis for Approve) (Fee $294)
❑ REQUEST FOR ALTERNATE MATERIAL
OR METHOD OF CONSTRUCTION
(See Reverse for Basis for Approval) (Fee $294)
❑ REQUEST FOR EXEMPTION FROM DISABLED
ACCESS DUE TO PHYSICAL OR LEGAL
CONSTRAINT (Fee $1,837)
(Ratifioaflon by the Board of Appeals will be required.)
For above requests, complete Sections 1, 2 8 3
below byprinting In Ink or typing.
JOB ADDRESS:
Plan Check # 2638-2078 # of Stories 2
Occupancy Classification R3
Use of Building SFR #of Units 1
ProlM Statue IN PLAN CHECK
Construction Type V -B
Vedred by + e
No. of Items
Fee due vot
D STRIBU ION: f
Owner Plan Check
Petitioner Inspector
Fire Other
SITE ADDRESSiG"i K"V IK rUJ Petitioner FARHAD MAN814ADI
Owner Mr. Mattew Jedalt fiRefidonerfis ea I(ectorenglneer)
Address 29 Andamo Address 1800E.161h St.OTE.B
Newport Coast, CA Zip 92657 Santa An. CA Zip 12701
Daytime Phone ( 714) n+s-yae Dama hne (�7 )33 tA4 tho zz /s
G v
2 REQUEST: Submit Plans it necaossaryto Illusto re sl. Additional sheets or data may be a( ached.
JUSTIFICATIONIFINDINGIS OF EQUIVALENCY: CODE SECTIONS:
Removal of the existing slab would require total demolition of the
Parlloners Position STRUCTURAL ENGINEER
Signature CA Professicnel Lio. # C 38840 Dale 3-28-2019
DEPARTMENQ Ar�11ON: In aocoMencewith: ❑ CBC 104.11/CFC 104.9 [1 CBC 104.101CFC 104.8
V (Alternate materials 8 methods) (CBC Modification)
❑ Concurrence from Fire Code Circlet Is required. ❑ Approved ❑ Disapproved ❑ Written Comments Attached
By: Date
❑ Request (DOES) (DOES NOT) lessen any fire protection requirements.
❑ Request (DOES) (DOES NOT) lessen the structural Integrity
Ip The Request is /Granted ElDenied (See reverse for V�
NNpp ❑ Granted (Ratification required) appeal Information)
Signature
Print Nem
Position CHIEF BUILDING OI
APPEAL OF DIVISION ACTION TO THE BUILDING BOARD OF APPEALS (See Reverse)
(Signature, statement of owner or applicant, statement of reasons for appeal and filing fees are required.)
CASHIER RECEIPT NUMBER: �,-% 3� Formslmodif 09/21/18
10-l�l,net
f4l ---- - - - - - - - -
T
J
W
W
H
L4r•J
Z
FO
VNW
zr0EN
J W
K
as
rnM
§are
.2
pZ0Q
W
t0
a u�i
m
N
d Ul
-80 U)- = U
U
nod -I s wo
►' N
A d- �W
P n£ U in
w L
Q N
Li
W
Cl)Z
W px
WWQ
9
Y O
3�3
N
I— _
Q
3
_j
C
W
4
- 9 m n
UL
14
W
c
ag
mod -I • W 4
a o
.. F W
m.�.
0
w
a
a LJ
�J
d
D
9a
n N
91=
U, -!,x
T
o 3
,�1
$W
N i
fI. �
0 "a3 "D3
m .
CID cli
I 1 7
W px
WWQ
J(�NO
EW
Y O
3�3
N
N
iOkD� X
Q
3
_j
QLLN
CID cli
I 1 7
PRODUCT DATA SHEET
Sika° MB Redline
SOLVENT FREE, FAST EPDXY MOISTURE BARRIER
PRODUCT DESCRIPTION
Sika® MB Redline is a 2 -component, rapid curing, solvent
free, low viscosity, epoxy moisture control system for
use with all flooring systems that require protection
from subfloor moisture.
USES
• Moisture barrier to help control moisture propagation
in cementitious substrates with a moisture content not
exceeding 6 %by Tramex Method, residual moisture up
to 100 % R.H. or 25 Ib/1000 ft2/24 h (11.4 kg/92.9
m2/24 h)
• For substrate consolidation on concrete, cement and
gypsum screeds
• Adhesion promoter for old and new adhesive residues
In conjunction with other Sika® products
PRODUCT INFORMATION
CHARACTERISTICS / ADVANTAGES
• Cures in 3 hours for fast turnaround jobs
• Can be used with carpet, resilient flooring, wood floor-
ing, floating floors and all types of floor that require
subfloor moisture protection
• Solvent -free (100% solids)
• Easy roller applied application, low viscosity
• Convenient, easy to mix packaging
• Shorter construction periods
• Excellent penetration and stabilization of the substrate
• Reduction of adhesive consumption
• Suitable for use on floors with radiant heating
• Compatible with Sika Bond® wood flooring adhesives
and Sika* Levels.
APPROVALS/STANDARDS
• Meets ASTM F 3010
Chemical Base
Two component epoxy
Packaging
2 gal (7.6 L) pall
Color
Red tint
Shelf Life
24 months from date of production if stored properly in undamaged sealed
containers
Storage Conditions
Store dry at 50-77 •F (10-25 *Q. Protect from moisture.
Density
66 lb/ft3(1.05 kg/1)
Product Data sheet
Sika• MB Redline
February 2019, Version 01.04
020512081000000010
1/4
TECHNICAL INFORMATION
Permeability to Water Vapor 0.06 g/m2 - 24hour-mmHG (ASTM E-96)
APPLICATION INFORMATION
Coverage
Coverage per pall
Moisture barrier 200-250 f .2(18.5 - — 23.2 m2)
Adhesion promoter or 300-350 ft2 (27.9-32.5 M2)
Surface consolidator
(Coverage figures do not Include allowance for surface profile and porosity or material waste).
Product Data Sheet
Sika- MB Redline -
February 2019, Version 01.04
O20512081000000010
2/4 BUILDING TRUST
Application Recommended Results in
Coatings
Moisture barrier only min.1 Mirror like finish
Substrate min.1 Good penetration
consolidation only
Adhesion promotion min.1 Mirror like finish
only
Moisture barrier+ min. 2 Mirror like finish
substrate consolidation
Moisture barrier+ min. 2 Mirror like finish
adhesion promotion
MUST produce a monolithic, pinhole -free finish with a continuous flim. The
need for multiple coats Is directly related to surface absorption.
Ambient Air Temperature
50°-86 7 (10°-30 °C)
Substrate Temperature
50°-86 °F (30°-30 °C)
Must be minimum 5 OF (3 °C) above the measured dew point temperature.
Pot Life
60 °F 10 °C) — 16 minutes
73 7 (20 °C) -12 minutes
Working time temperature: 50°-80 °F (100-26.7 °C)
Cure Time
60°F (10 `C) 3.5 hours
73 °F (23 °C) 3 hours
Minimum curing time, prior to walking on prlmer/or for applying Slkalionde or Sika• Level.
Application Time
Civercoating Applica- Minimum Maximum
tion Time Window"
SlkaBond" Wood 3 hours 16 hours
Flooring Adhesive
Sika® Level -02 EZ Primer 3 hours 48 hours
+Sika° Level
cementitious product
Sika®MB Redline 3 hours 24 hours
(2nd coat)
• When Slka• MB Redilne Is left on the substrate for more than the maximum allowable open time, the surface
must be mechanically prepared Ike. sanded) solvent wiped before proceeding.
Product Data Sheet
Sika- MB Redline -
February 2019, Version 01.04
O20512081000000010
2/4 BUILDING TRUST
APPLICATION INSTRUCTIONS
SUBSTRATE PREPARATION
• Substrate must be clean, dry, sound and homogeneous,
free from oils, grease, dust, and loose or friable
particles. Paint, laitance, and other poorly adhering
contents must be mechanically removed.
• Substrate must have an open textured surface to allow
Sika® MB Redline to penetrate. (i.e. Blast cleaning,
grinding are considered acceptable means to achevie
the desired surface profile. Acid and chemical etching
are not acceptable).
• At least 50 % of the surface area must be cleared of re-
sidual adhesive and cutbacks. (i.e. by grinding or mech-
anical substrate preparation)
• old cutback can contain asbestos which is dangerous
for the health so do not grind, sand or blast. Refer to
the Resilient Floor Covering Institute's publication "re-
commended work practice for removal of resilient floor
coverings" for instruction.
• Minimum substrate compressive strength > 1,160 psi.
Tensile Bond strength > 116 psi at the time Sika* MB
Redline Is applied.
• Repair with Sika• Level SkimCoat or SlkaQuick° mortar
before priming.
• The floor must be cleaned with an Industrial vacuum
prior to Installation of the Slka® MB Redline.
• On fiber reinforced concrete, fibers should be flamed
off the surface prior to application of Sika® MB Redline
as a moisture barrier.
• Before overall installation begins, Sika' recommends
the application of several small test patches to determ-
ine primer application requirements and acceptability
of final product performance.
MIXING
• Add one full can of Component A to one full can of
Component B then mix with an electric drill and mixing
(Jiffy Mixer type) paddle at a low speed to reduce air
entrainment (300-400 rpm).
• Using a paint stick or similar Is not sufficient to mix the
product.
• A minimum mixing time of 3 minutes shall be observed,-
mixing
bserved;mixing shall continue until a homogeneous mix has
been achieved.
• Scrape sides of pail with paint stick or paddle to ensure
all contents are thoroughly mixed together.
• Unmixed material applied to the floor will not cure
properly.
APPLICATION METHOD/ TOOLS
• Apply uniformly (in 2 directions 90•) to the substrate
using a medium nap roller, ensuring that a continuous
coat is achieved over the entire surface (MUST pro-
duce a mirror like finish).
Product Data $beet
Sika' MB Redline
February 2019, Version 01.04
020512081000000010
3/4
CAUTION: The unit can conduct to a rapid reaction that
can generate high temperatures and produce steam. In
order to avoid any risks, the entire content of the buck-
et have to be poured on the substrate immediately after
mixing. If any reaction start In the bucket, do not touch
the bucket and carry carefully the bucket by the handle
outside until it cool down.
2 coats application: Apply the first coat at 75-115
ft2/gal. Apply the second coat at 150-225 ft2/gal in ac-
cordance with the application time window*. Then fol-
low one of the option:
• 0 tiu on 1: Broadcast to refusal with oven dried silica
sand (20/30) on the second coat immediately. Sweep
sand once the epoxy is cured. Apply Sika® Level
products on cured epoxy.
• ODtl,_,on 2: Apply Sika® Level -02 EZ Primer in accordance
with the application time window*. When the primer is
dry, apply Sika® Level products.
'ref. to applictlon time In sections above
CLEANING OF TOOLS
• Clean all tools and application equipment with clean -
Ing solvent (Xylene, MEK are effective).
• Hardened/cured material can only be removed mech-
anically.
LIMITATIONS
• Sika" MB Redline must not be applied to a visibly wet
substrate.
• Only protects from moisture coming from below the
concrete. Does not prevent moisture occurring
between the Sika® MB Redline and the floating floor
due to secondary sources of moisture or acclimation,
e.g. water condensation,
• Will not prevent hydrostatic pressure.
• Gypsum based subfloors are very susceptible to excess
moisture and will be degraded If exposed to excess
moisture from below or above. Sika® MB Redline will
not prevent damage to gypsum based subfloors that
are exposed to excess moisture levels and then will not
act as a moisture barrier.
• Sika® recommends the use Sika® Level products for
best results. Consult level/ patch system manufacturer
regarding priming and other application/limitation
guidelines prior to the placement of materials.
• Floor covering manufacturer's and wood flooring man-
ufacturer's recommendations, like room humidity
levels and wood acclimation requirements should be
strictly followed,
• When used In conjunction with SlkaBond® Wood Floor
Adhesives and floating floors, Sika® MB Redline does
not need an additional primer or to be broadcasted
with sand.
• Sika® does not make any standing recommendations as
to the structural integrity of old adhesive residues or
subflooring materials that are not manufactured by
Sika".
BUILDING TRUST
BASIS OF PRODUCT DATA
Results may differ based upon statistical variations de-
pending upon mixing methods and equipment, temper-
ature, application methods, test methods, actual site
conditions and curing conditions.
OTHER RESTRICTIONS
See Legal Disclaimer.
ENVIRONMENTAL, HEALTH AND SAFETY
For further information and advice regarding transporta-
tion, handling, storage and disposal of chemical
products, user should refer to the actual Safety Data
Sheets containing physical, environmental, toxicological
and other safety related data. User must read the cur-
rent actual Safety Data Sheets before using any
products. In case of an emergency, call CHEMTREC at 1-
800-424-9300, International 703-527-3887.
Sika Corporation
201 Polito Avenue
Lyndhurst, N107071
Phone: 800-933-7452
Fax: 201-933-6225
Product Data Sheet
Slka° M8 Redline
February 2019, Version 01.04
020512061000000010
Sika Mexicana S.A. de C.V.
Carr store Libre Celays Km. 8.5
Frace. Industrial Balvanere
Corregidora, Queretaro
C.P. 76920
Phone: 52 442 2385800
Fax: 524422250537
LEGAL DISCLAIMER
• KEEP CONTAINER TIGHTLY CLOSED
• KEEP OUT OF REACH OF CHILDREN
• NOT FOR INTERNAL CONSUMPTION
• FOR INDUSTRIAL USE ONLY
• FOR PROFESSIONAL USE ONLY
Prior to each use of any product of Sika Corporation, its
subsidiaries or affiliates ("SIKA`), the user must always
read and follow the warnings and instructions on the
product's most current product label, Product Data
Sheet and Safety Data Sheet which are available at
usa.sika.com or by calling SIKA's Technical Service De-
partment at 800-933-7452. Nothing contained in any
SIKA literature or materials relieves the user of the oblig-
ation to read and follow the warnings and instructions
for each SIKA product as set forth in the current product
label, Product Data Sheet and Safety Data Sheet prior to
use of the SIKA product.
SIKA warrants this product for one year from date of In-
stallation to be free from manufacturing defects and to
meet the technical properties on the current Product
Data Sheet if used as directed within the product's shelf
life. User determines suitability of product for intended
use and assumes all risks. User's and/or buyer's sole
remedy shall be limited to the purchase price or replace-
ment of this product exclusive of any labor costs. NO
OTHER WARRANTIES EXPRESS OR IMPLIED SHALL AP-
PLY INCLUDING ANY WARRANTY OF MERCHANTABIL-
ITY OR FITNESS FOR A PARTICULAR PURPOSE. SIKA
SHALL NOT BE LIABLE UNDER ANY LEGAL THEORY FOR
SPECIAL OR CONSEQUENTIAL DAMAGES. SIKA SHALL
NOT BE RESPONSIBLE FOR THE USE OF THIS PRODUCT
IN A MANNER TO INFRINGE ON ANY PATENT OR ANY
OTHER INTELLECTUAL PROPERTY RIGHTS HELD BY OTH-
ERS.
Sale of SIKA products are subject to the Terms and Con-
ditions of Sale which are available at
httPs:Husa.sika.com/en/group/SikaCorp/termsandcon-
ditions,html or by calling 201-933-8300.
Sika Canada Inc.
G01 Delmar Avenue
Pointe Cialre
Quebec H9R 4A9
Phone: 514-697-2610
Fa%:514-694-2792
4/4 BUILDING TRUST