Loading...
HomeMy WebLinkAboutS2019-0028 - MiscMIDGET A Professional Inspection Service 365 Mainsail Road, Oceanside, CA 92054 s Report of Special Inspection Office; (760) 757-0556 Cell: (949) 370-7922 Fax: (760) 757-1064 SXN-008 N29 606Y Dr PermitNumber .- w" E" InspectionType(s) , InspectionDate(s) ` !" 1"`� [ J Periodic [ J Continuous Describe Inspection Made, including Locations: �� ar e _ s.- _.. l ��/..l-�''!r-2--I<"'.. (( -< •^..tr '. ."`�}" � S )� f.�'�.I /� ..._.�:.-a.rb'�1—Di. 2 e�.. .....,v�\'1 C..__1tY i�f :)l �C•�' �'S�1 V, )(..r� List Tests Made: _- VL, 2`'\V^) ( —4 -- + -L Total Inspection Time Each Day: Date 41 Hours List Items Requiring Correction, include uncorrected items previously listed Comments: To the best of my knowledge, the work inspected was in accordance with the Building Department approved design drawings, specifications and applicable workmanship provisions of the U.B.C. except as noted above. All inspections based on four hour minimum. Inspections exceeding four hours will be billed at eight hours. Any inspections beginning before 12:00 noon and end after 12:00 noon will be�billed as eight hours Signed: t 1ii1 i ,.,� Date Print Full Name: -LL K� E 1L!('-,3'( Registration No. " � ij() FORM S02,01 SOUTHWEST ®®®®AW® ®® Inspection & Telling, Inc. 441 commercial way, La Habra, CA 90631-6168 (562)941-2990 (714)526-8441 FAX (562)946-0026 FIELD DATA ON TEST SPECIMENS 3glq-00A8 --- ASTM C31, C138, C143, C172, C173, C231, C1064 -- lggq Galaxy C)C CONCRETE: X MORTAR: SHOTCRETE: CORES: GUNITE: ADDRESS: 1924 GALAXY, NEWPORT BEACH JOB #: DATE: 04/10/2019 JOB NAME: WELBOURN PERMIT M S2019-0028 ISSUED BY: NEWPORT BEACH ARCHITECT: ENGINEER: CONTRACTOR: SERGIO COMACHO SUB: LOCATION IN STRUCTURE: JACUZZI DECK TRACT: PHASE: LOT M CONCRETE SUPPLIER: PLANT: MIX M TYPE OF CEMENT: ADMIXTURE: TICKET M SLUMP: 0.00 in. WATER ADDED: 0 gal. AIR TEMP: 0 F CONCRETE TEMP: 0 F MIXING TIME: 0 min. TIME CAST: 00:00 DATE CAST: 02/18/2019 RECEIVED AT LAB: 04/09/2019 SPECIMENS MADE BY: SPECIFIED PSI @ 28 Days: 4500 LAB M 138702 CLIENT: MIDGET INSPECTION TESTING INFORMATION: SAMPLE IDENTIFICATION: 1814124 1814125 1814126 AGE DAYS: 28+ 28+ 28+ DATE TEST: 04/10/2019 04/10/2019 04/10/2019 SIZE (in.): Height X Diameter 6.000 X 4.000 6.000 X 4.000 6.000 X 4.000 AREA (in.k): 12.57 12.57 12.57 CRUSH LOAD (lbs.): 68747 70950 69340 COMPRESSIVE STRENGTH (psi.): 5470 5640 5520 HEIGHT -DIAMETER RATIO: 1.50: 1 1.50: 1 1.50: 1 CORRECTION FACTOR: 0.96 0.96 0.96 CORRECTED STRENGTH (psi.): 5250 5410 5300 BREAK TYPE: V V III C.T.M. USED: Forney96 Forney% Forney96 REMARKS: CORES ASTM C39, C174, C192, C470, C617, C42 COMPLIES: DOES NOT COMPLY: FOR INFORMATION: X THIS REPORT SHALL NOT BE REPRODUCED, EXCEPT IN FULL, WITHOUT THE APPROVAL OF SOUTHWEST INSPECTION AND TESTING, INC. SAMPLES CAST BY OTHERS: NOTICE:These test results are from samples cast by inspectors or technicians not employed by our firm. They were either delivered to our laboratory or picked up by our driver. We will accept no responsibility for the inspection made on the jobsite by the inspector, furthermore we do not take responsibility for any information on this report other than the strength as tested and reported. ASTM C39 BREAKS: 1=CONE - 11=CONE AND SPLIT - RESPECTFULLY SUBMITTED SOUTHWEST INSPECTION AND TESTING ZAFAR PRINCIPAL ENGINEER 111=COLUMNAR - IV=SHEAR - V=SIDE FRACTURES - VI=POINTED pool engineering May 20, 2019 MA C-alaxy b, The Welbourn Residence May 20, 2019 Page 1 of I Victory Pools 1164 N. Sacramento St. Orange, CA 92867---- --_. �r Re: Construction of the Pool Engineering, Inc. (PEI) Detail #640 and Special Detail `A'at the Welbourn Residence, 1924 Galaxy Dr., Newport Beach, CA To Whom It May Concern: In accordance with your request, I have reviewed the digital photographs provided by Victory Pools. The pictures depicted an existing pool being remodeled showing the added steel cage for a baja shelf and raised bond beam. Per phone conversation with Victory Pools, the baja shelf was cleared of debris and shot solid of concrete. Based on a cursory review of the photographs, the reinforcing appears to be in general conformance with PEI Detail #640 and Special Detail W. If I can be of any further assistance, please do not hesitate to contact me. Best Regards, POO glYl 6Yl C. Charles Volder, M.S.C.E., P.E. Associate Engineer 1201 N. Tustin Avenue, Anaheim, California 92807 Fax: (714) 630-6114 Phone: (714) 630-6100 szoia-oo�s ';a laxy Dr CHRISTOPHER JEAN & ASSOCIATES, I19/ 124 NC. ACOUSTICAL CONSULTING SERVICES June 19, 2019 MS. CHRISTI WALBOURNE 1924 Galaxy Drive Newport Beach, CA 92660 Business License: #BT30044674 SUBJECT: RESULTS OF ACOUSTICAL CERTIFICATION MEASUREMTIN"T' FOR 1924 GALAXY DRIVE -- CI"I'Y OF NEWPORT BEACH Dear Ms. Walbourne: We are pleased to inform you that the pool equipment installation located at 1924 Galaxy Drive in the City of Newport Beach complies with the City's 55 dBA noise limit. No additional noise mitigation is necessary. The installation was measured on Wednesday, June 19, 2019, using a Larson Davis Model 700 Type 2 Sound Level Meter. The installation was observed to consist of a single Pentair Intelliflo pump, a single Pentair Whisperflo pump and a MasterTemp 400HD, all located in a side yard setback. The measurement microphone was placed just beyond the top of the nearest property line wood fence directly opposite the pool equipment. The measurement reported a level of 54 dBA for both pumps and the heater unit operating simultaneously. 'Phis level complies with the City's 55 dBA noise limit. Thank you, and if there are any questions, please do not hesitate to call. P;7epareby: Christoplier.Jear. President P. O: BOX 2325 • FULLERTON, CALIFORNIA • 92837 PHONE: 714-805-0115