Loading...
HomeMy WebLinkAboutS2019-0044 - MiscSz0l9 •o0uu 1601 Doro+hy Ln DL Acoustics 14301 Middletown Lane Westminster, CA 92683 /%/C{l&CbmwleVh;AlL'� Voice/Fax 714.373.3050 dlubman@dlacoustics.com July 11, 2019 Homeowner 1601 Dorothy Ln Newport Beach, CA, 92660 Report emailed to: ryan@ryandburress.com Pool and or Spa Noise report for residence at 1601 Dorothy Ln, Newport Beach, CA Dear Homeowner: At about 12:00 p.m. Tuesday, July 11, 20191 measured the pool and or spa equipment noise at your nearest neighbor's residence to test for compliance with the Newport Beach noise regulation (10.26.025). Newport Beach Residential Noise Standard For Noise Zone 1 (residential) the N. B. regulation's daytime noise level standard (maximum noise level from 10 p.m. to 7 a.m.) is 55 dBA — corrected for ambient noise. The nighttime noise standard (max noise level from 7 a.m. to 10 p.m.) is 50 dBA. The measurement is corrected for ambient noise and rounded to the nearest decibel as shown below. I am pleased to report that measured pool and or spa apparatus noise meets the Newport Beach noise standard for 24-hour use. Pertinent details of my findings are reported below. Locations and values of daytime noise measurements Uncorrected pool and or spa noise + ambient noise measured at property line: 48.96 dBA Ambient noise level measured at this location: not needed Pool and or spa equipment noise corrected for ambient noise: not applicable Pool and or spa equipment noise rounded to the nearest decibel: 49 dBA 49 dBA (Pass for 24 hour use) The currently installed pool and or spa apparatus noise of 49 dBA meets the Newport Beach noise code for both "daytime" use (7 a.m. to 10 p.m.) and "nighttime" use (10 p.m. to 7 a.m.), since the noise corrected for ambient does not exceed 50 dBA. If you have any questions about this report, please do not hesitate to contact me at (714) 373- 3050 or by email at dlubman(a)dlacoustics.com Sincerely yours, f" L" David Lubman, FASA, FINCE Acoustical Consultant Orange County Certification #200524 July 11, 2019 APPENDIX A: Measurement Instrumentation Equipment The acoustical equipment used in the performance of this test is in accordance with ASTM and ANSI (American National Standards Institute) requirements. Key elements are as follows: Critical sound measuring instruments (sound analyzer, calibrator, and microphone) are annual calibrated by an independent NAVLAP certified laboratory. The most recent calibration was on 08/01/18. All calibration documents are available for inspection upon request. Critical instruments employed were: Bruel & Kjaer— Type 2270 Type I Precision Sound Analyzer SN # 3002720 Bruel & Kjaer - Type 4189 microphone, SN # 2850866 Bruel & Kjaer— Type 4231 Field Sound Calibrator, SN # 2588671 Continuous Inspection ;& Materials Vesting Al Ah, A&Ah, All A& All A1111111111� A&AAL A& All =�Ah. 111s])ect1on c`*'', Testing, Inc. 441 Commercial Way, La .Habra, CA 90631-6.168 (562)941-2990 - (714)526-844: FAX (562)94(1-002(, FIELD DATA ON TEST SPECIMENS 1601 Nor -616 GIrl --- ASTM C31, C138, C143, 0172, C173, C231, C1064 --- CONCRETE: MORTAR: SHOTCRETE:XCORES: GUNITE ADDRESS: 1601 DOROTHY LANE, NEWPORT BCH JOB #: DATE: 05/16/2019 JOB NAME: MITCHELL PERMIT#: S2019-0044 ISSUED BY: ARCHITECT: ENGINEER: LACHER ENGINEERING CONTRACTOR: RYAN BURRESS SUB: WEST COAST SHOTCRETE LOCATION IN STRUCTURE: BOTTOM OF POOL TRACT: PHASE: LOT #: CONCRETE SUPPLIER: GARY BALE PLANT: MIX #: 7 1/2 -1 TYPE OF CEMENT: V ADMIXTURE: TICKET #: 291586 SLUMP: 0.00 in. WATER ADDED: O gal; AIR TEMP: 0 F CONCRETE TEMP: MIXING TIME: TIME CAST: 08:30 DATE CAST: 04/11/2019 RECEIVED AT LAB: 04/25/2019 SPECIMENS MADE BY: RICHARD LUIZ SPECIFIED PSI @ 28 Days: 4500 LAB #:940679 CLIENT: RICHARD LUIZ TESTING INFORMATION: SAMPLE IDENTIFICATION: 1822254 1822255 1822256 AGE DAYS: 28 28 28 DATE TEST: 05/09/2019 05/09/2019 05/09/2019 SIZE (in.): Height X Diameter 8.000 X 4.000 8.000 X 4.000 8.000 X 4.000 AREA (in.A2): 12,57 12.57' 12.57 CRUSH LOAD (lbs:):: 84110 85720 87288 COMPRESSIVE STRENGTH (psi.): 6690 6820 6940 HEIGHT -DIAMETER RATIO: CORRECTION FACTOR: CORRECTED STRENGTH (psi.): BREAK TYPE: 111 II 11 C.T.M. USED: Forney96 Forney96 Forney96 REMARKS: ASTM C39 C174, C192, C470,, C617, C42 COMPLIES: X DOES NOT COMPLY: FOR INFORMATION: THIS REPORT SHALL NOT BE REPRODUCED,. EXCEPT IN FULL, WITHOUT THE APPROVAL OF SOUTHWEST INSPECTION AND TESTING, INC SAMPLES CAST BY OTHERS: RESPECTFULLY SUBMITTED SOUTHWEST INSPECTION AND TESTING NOTICE:Thesetest results are from samples cast byinspectors or technicians not employed by our firm. They were either delivered to our laboratory or picked up by our driver. We will accept no responsibility for the inspection made on the 7obsite.by the inspector, furthermore we ZAFAR AHMED do not take responsibility for any. information on this PRINCIPAL ENGINEER report other than the strength as: tested. and reported. ASTM C39 BREAKS: 1=CONE - t1=CONE AND SPLIT - I11=COLUMNAR = IV=SHEAR - V=SIDE FRACTURES - VI=POINTED City of Newport Beach Special Inspector Manual �1.�F"PQttl. r CITY OF NEWPORT BEACH COMNMUNITY DEVELOPMENT DEPARTIWENT 3UMDING DItiSIONT 100 Civic Center Drive: I P.O. Box 1768.E Newport Beach,. CA 92658 wvvv/.ne11vooribeachca:aov ) (949)6-",43200 SPECIAL INSPECTION REPORT Project Address: ( Y .� X`t�[)T[!1L—M '71 Permit Number: G WIP—04OL}_ Inspection Type (s)- W--7—cvne<.T-f-- S2of9 -ooyN /G01 Doro4Aiy ( ) Periodic (Continuous .:Describe Inspection, Including Location(s): List Tests Madei e_ C `�?� i�lv. L i�7 �✓ l�ie1�, �7 ���i 1c., g �..!+� �,.,, y, 67