HomeMy WebLinkAboutS2018-0216 - Misc52016-0,Z16 CITY OF NEWPORT BEACH 006 Leee. orJ 4n COMMUNITY DE VELOPMENT DEPARTMENT BUILDING DIVISION 100 Civic Center Drive I P.O. Box 1768 1 Newport Beach, CA 92658 www.newportbeachca.gov 1 (949) 644-3200 SPECIAL INSPECTION REPORT Project Address: Miller Residence, 2006 Leeward, Newport Beach Permit Number: S2018-0216 Inspection Type (s): Reinforced Concrete Inspection Date (s):01111/2019 EJPeriodic MContinuous Observed the placement and consolidation of 38 cubic yards of 4500 psi Shotcrete, Cemex mix design #1419319 at pool and spa. All rebar and hardware was securely tied in place at time of pour, and all required clearances and coverages were maintained. as two 6"x12" cylinders were taken from load 1 ticket #28188592 Slump = 2" Concrete temperature = 72 F 77' fi. 7777777777,',7711'A- 01/11/2019 '' .., Totaf,IbspYtt(oti;'[IIi.O SackDa , 01/11/2019 To the best of my knowledge, the work inspected was in accordance with the Building Division approved design drawings, specifications and applicable workmanship provisions of the U.B.C. except as noted above. 51" bff.Pe WM.Ift OW25/2015 01/11/2019 Christopher J. Whelan NB -0661 51" bff.Pe WM.Ift OW25/2015 Continuous Inspection & Materials Testing SOUTHWEST 0000000000000®O Inspection & Testing, Inc. 441 Commercial Way, La Habra, CA 90631-6168 (562)941-2990 - (714)526-8441 FAX (562)946-0026 SAMPLE IDENTIFICATION: FIELD DATA ON TEST SPECIMENS DOTOW AGE DAYS: 28+ ,2006 / CCW0rd `n --- ASTM C31, C138, C143, C172, C173, C231, C1064 - -- CONCRETE: MORTAR: SHOTCRETE: X CORES: GUNITE: ADDRESS: 2006 LEEWARD, NEWPORT BEACH JOB #: DATE: 04/12/2019 JOB NAME: MILLER RESIDENCE PERMIT M S2018-0216 ISSUED BY: NEWPORT BEACH ARCHITECT: ENGINEER: POOL ENGINEERING INC. CONTRACTOR: MATA SUB: HEIGHT -DIAMETER RATIO: LOCATION IN STRUCTURE: POOL AND SPA CORRECTION FACTOR: TRACT: PHASE: LOT #: CONCRETE SUPPLIER: CEMEX PLANT: 4486A MIX #: 1419319 TYPE OF CEMENT: ADMIXTURE: TICKET M 28188592 SLUMP: 2.00 in. WATER ADDED: 0 gal. AIR TEMP: 62 F CONCRETE TEMP: 72 F MIXING TIME: TIME CAST: 13:35 DATE CAST: 01/11/2019 RECEIVED AT LAB: 04/01/2019 SPECIMENS MADE BY: SPECIFIED PSI @ 28 Days: 4500 LAB M 138106 CLIENT: CHRIS WHELAN INSPECTIONS TESTING INFORMATION: SAMPLE IDENTIFICATION: 1811756 1811757 AGE DAYS: 28+ 28+ DATE TEST: 04/02/2019 04/02/2019 SIZE (in.): Height X Diameter 12.000 X 6.000 12.000 X 6.000 AREA (in.A2): 28.27 28.27 CRUSH LOAD (lbs.): 204590 202580 COMPRESSIVE STRENGTH (psi.): 7240 7170 HEIGHT -DIAMETER RATIO: CORRECTION FACTOR: CORRECTED STRENGTH (psi.): BREAK TYPE: III I C.T.M. USED: BK BK REMARKS:_ ( OVER 28 DAYS) ASTM C39, C174, C192, C470, C617, C42 COMPLIES: X DOES NOT COMPLY: FOR INFORMATION: THIS REPORT SHALL NOT BE REPRODUCED, EXCEPT IN FULL, WITHOUT THE APPROVAL OF SOUTHWEST INSPECTION AND TESTING, INC. SAMPLES CAST BY OTHERS: NOTICE:These test results are from samples cast by inspectors or technicians not employed by our firm. They were either delivered to our laboratory or picked up by our driver. We will accept no responsibility for the inspection made on the jobsite by the inspector, furthermore we do not take responsibility for any information on this report other than the strength as tested and reported. ASTM C39 BREAKS: 1=CONE - 11=CONE AND SPLIT - RESPECTFULLY SUBMITTED SOUTHWEST INSPECTION AND TESTING ZAFAR AHMED PRINCIPAL EN R 111=COLUMNAR - IV=SHEAR - V=SIDE FRACTURES - VI=POINTED W/9 OV 20061-eeworj Zrl 19/080 CHRISTOPHER JEAN & ASSOCIATES, INC. ACOUSTICAL CONSULTING SERVICES May 2, 2019 Business License: #BT30044674 MR. JESUS MARTINEZ MATA CONSTRUCTION 910 E. 4th Street Santa Ana, California 92704 SUBJECT: RESULTS OF ACOUSTICAL CERTIFICATION MEASUREMENT FOR 2006 LEEWARD LANE -- CITY OF NEWPORT BEACH Dear Mr. Martinez: We are pleased to inform you that the pool equipment installation located at 2006 Leeward Lane in the City of Newport Beach complies with the City's 55 dBA noise limit. No additional noise mitigation is necessary. The installation was measured on Thursday, May 2, 2019, using a Larson Davis Model 700 Type 2 Sound Level Meter. The installation was observed to consist of one Jandy E -Pump variable speed pump, one Jandy Stealth pump, and a Jandy JXi heater, all located in a side yard setback. The measurement microphone was placed just over the top of the nearest property line wall directly opposite the pool equipment. The measurement reported a level of 52 dBA for both pumps and the heater operating simultaneously. This level complies with the City's 55 dBA noise limit. Thank you, and if there are any questions, please do not hesitate to call. Prepare by: s� Christopher Jean President P. O. BOX 2325 • FULLERTON, CALIFORNIA • 92837 PHONE: 714-805-0115