TEST SPECIMEN AND COMPRESSIVE STRENGTH DATA SHEETalo p NQS+ QUS Ln
PROJECT AND CAST DATA (PERFORMED BY OTHERS AND NOT VERIFIED BY LAB) /9
PROJECT NAME: - INSPECTION FIRM OR CLIENT: Shoreline Special Inspection, Inc.
PROJECT ADDRESS: 2024 Nautlus Lane INSPECTOR'S NAME: Michael Vidovith
Newport Beach, CA INSPECTOR'S LICENSE NO.:
PERMIT NUMBER: -
FIELD IDENTIFICATION:
CAST DATA (ATTACH DATA SHEET OF OTHERS WHEN AVAILABLE)
CAST DATE
6/19/19
DESCRIPTION
SHOT.R TF CORES - PAN
CEMENTTYPE
-
CONTRACTOR
-
SPECIFIED Fc - PSI
For Information Only
ADMIXTURE
-
CONC. SUPPLIER
-
CAST BY
Michael Vidovith
SLUMP
-
PLANT
-
NO. OF SAMPLES
1 Panel 13 Cores
AIR CONTENT
-
MIX DESIGN NO.
-
TOTAL YARDS
-
AIR TEMP.
TICKET NUMBER
-
CAST/MIX TIME
-
CONC TEMP.
28
LOCATION IN
STRUCTURE
No Paperwork Submitted
3.96
3.9612.32
NOTES
Specimens were tested in accordance with ASTM C1231
(Unboncled Method).
El
5.39 5.39 1.36
Results relate only to the tested specimens.
LABORATORY COMPRESSIVE STRENGTH DATA PER ASTM C42 AND C39
)ATE SPECIMENS RECVD.
6/21/19
EQUIPMENT USED
On File
ZEPORT DATE
17/17/19
I SN OF EQUIPMENT
IOn File
'ECHNICIAN
10n File
I CALIB. /REGAL. DATE
10n File
SPECIMEN IDENTIFICATION
NUMBER
AGE AT
TEST
(DAYS)'
DATE
OF
TEST
TIME
OF
TEST
SPECIMEN DIMENSIONS41M.'
AREA'
3 4 SQ. IN.
LOAD
LBS.
F'C
PSI
BREAK
TYPE'
1
2
5 6 hid
87100.1. 1
28
7/17/19
11:52 AM
3.96
3.9612.32
69,460
5,301
3
5.40 5.40 1.36
87100.1.212
28
7/17/19
11:55 AM
3.96
3.96
69,890
5,334
3
5.36 5.36 1.35
35
87100.1.3
28
7/17/19
11:58 AM
3.96
3.9612.32
67,490
5,151
3
5.39 5.39 1.36
Avg. F'c 2e= 5,262
, - ,e5, —1-1- � I UVIUoU Uy Ll e �1Ie„1
2 - Dimensions 1 and 2 = Diameters: Dimensions 3 and 4 = Capped Core Height: Dimensions 5 and 6 = Uncapped Core Height
When Dimensions 3 and 4 are Missing, Specimens were Tested using ASTM C1231 (Unhanded Caps).
3) Correction factor for h/d <1.75 applied per ASTM C42 (based on uncapped height divided by average diameter.)
4 - Break Type Designation Per ASTM C39 Figure 2: 1 = Cone, 2 = Cone and Crack, 3 = Columnar, 4 = Diagonal, 5 = Side Fracture, 6 = Side Fracture Point
COMPLIANCE WITH SPECIFIED STRENGTH / COMMENTS: THEAVERAGE 28 -DAY COMPRESSIVE STRENGTH IS LESS THAN THE SPECIFIED VALUE
Author dSig ure
Mi OF -003.1
B -12W
DL Acoustics
14301 Middletown Lane Westminster, CA 92683
ReS"Vh& COnUdliftkA160"sGcs Voice/Fax 714.373.3050 dlubman@dlacoustics.com
Adam Holiday September 18, 2019
2024 Nautilus Ln
Newport Beach, CA, 92660 Report emailed to: adamholiday26@gmail.com
Pool and or Spa Noise report for residence at 2024 Nautilus Ln, Newport Beach, CA
Dear Mr. Holiday:
At about 11:00 a.m. Wednesday, September 18, 2019 1 measured the pool and or spa
equipment noise at your nearest neighbor's residence to test for compliance with the Newport
Beach noise regulation (10.26.025).
Newport Beach Residential Noise Standard
For Noise Zone 1 (residential) the N. B. regulation's daytime noise level standard (maximum
noise level from 10 p.m. to 7 a.m.) is 55 dBA— corrected for ambient noise. The nighttime noise
standard (max noise level from 7 a.m. to 10 p.m.) is 50 dBA. The measurement is corrected for
ambient noise and rounded to the nearest decibel as shown below.
I am pleased to report that measured pool and or spa apparatus noise meets the Newport
Beach noise standard for 24-hour use. Pertinent details of my findings are reported below.
Locations and values of daytime noise measurements
Uncorrected pool and or spa noise + ambient noise measured at property line: 49.91 dBA
Ambient noise level measured at this location: not needed
Pool and or spa equipment noise corrected for ambient noise: not applicable
Pool and or spa equipment noise rounded to the nearest decibel: 50 dBA
50 dBA (Pass for 24 hour use)
The currently installed pool and or spa apparatus noise of 50 dBA meets the Newport Beach
noise code for both "daytime" use (7 a.m. to 10 p.m.) and "nighttime" use (10 p.m. to 7 a.m.),
since the noise corrected for ambient does not exceed 50 dBA.
If you have any questions about this report, please do not hesitate to contact me at (714) 373-
3050 or by email at dlubmanna.dlacoustics.com
Sincerely yours,
.6" L.Cr'17tc m
David Lubman, FASA, FINCE
Acoustical Consultant
Orange County Certification #200524
APPENDIX A:
Measurement Instrumentation
Equipment
September 18, 2019
The acoustical equipment used in the performance of this test is in accordance with
ASTM and ANSI (American National Standards Institute) requirements. Key elements
are as follows:
Critical sound measuring instruments (sound analyzer, calibrator, and microphone) are
annual calibrated by an independent NAVLAP certified laboratory. The most recent
calibration was on 07/31/19. All calibration documents are available for inspection upon
request.
Critical instruments employed were:
Bruel & Kjaer— Type 2270 Type I Precision Sound Analyzer SN # 3002720
Bruel & Kjaer - Type 4189 microphone, SN # 2850866
Bruel & Kjaer — Type 4231 Field Sound Calibrator, SN # 2588671
DL Acoustics
14301 Middletown Lane Westminster, CA 92683
ROSOa►Ch&COv=ditkI lC0UF 6 Voice/Fax 714.373.3050dlubman@dlacoustics.com
September 18, 2019
Receipt for $350 Payment in Full
One Pool and or Spa Sound Test for homeowner at 2024 Nautilus Ln, N.B. on 9/18/19
Check 1347 received from Adam Holiday dated 9/18/19
David Lubman
DL Acoustics
EIN 33-0246903
Thanks for your business!
V nar
OF7P�UhL INSPEETION
R P O R A T E D
Project Name Holiday Res
Date 06/19/19
ProjectAddress 2024 Nautilas
Permit # S2019-0090
Contractor Owner/Builder
Architect
Subcontractor Janco Concrete
JEngineer
❑ Concrete ❑ Pre -Stressed Concrete ❑ Masonry ❑ Epoxy ❑ Wood
[:]Structural Steel ❑ Fire Proofing ® Other Shotcrete
Description of work observed
Observation of Shotcrete at (E) pool
Reinforcing steel at duel drain trench at deep end,
Baja step,spa,and bond beam around top.
#3 bar dowel at 12" o/c verts and horizontals.
Wall and floor steel #3 at at 12" o/c, (3) #3 horizontal at top of bond beam and spa.
Reinforcing tied secure.
Observation of Shotcrete placement at bond beam,Baja step,drain trench, and spa.
Placed by ACI Certified nozzleman-Amador Beltran ID#01382557, Exp 10/22/2021
Shot placed evenly filling voids behind reinforcing steel and plumbing. Stuff removed
With compressed air. Shot application and material complies ASTM and CBC.
Sampled at 10:10 am, load #1, ticket#4548364
2" slump, concrete temp 78*F, Amb 63*F
12x12x6" panel shot by nozzleman
4500 psi shot,mix#53753A
Approximately 22 yrds placed
NOTICE: I hereby certify that, at the time of this inspection, I have observed all of the above reported work, unless otherwise noted. To the best of my
knowledge and belief, I have found this work to comply with the approved plans, specifications, and applicable section(s) ofthe governing Building Code, as
applicable to the municipality where this project is located. This report cannot be constructed to be a recommendation ofwork ofany nature to be performed.
It should be noted that our presence and the services provided do not relieve the contractorfrom its obligation to meet contractual requirements.
Reg Hrs. 4 hrs
The Owner or a successor in interest shall hold harmless Shoreline Special inspection, Inc., a California
0. T. hrs.
Corporation, from any and all legal proceedings of any nature whatsoever, that are related to the inspection
services provided in this report. Should Shoreline Special Inspection, Inc. be required to institute legal action for
Test Cyls
the collection of a debt incurred as a result of the acceptance of this report, Shoreline Special Inspection, Inc.
Type
shall be entitled to Attorney's fees d co incurred in said action.
Ninhnlac Na beth
!--
NB0450
Inspector/Technician Name
Inspector/Tec tnician's SignatureT
Certification #
854 Blue Heron Drive San Marcos, CA 92078 619-206-3884