HomeMy WebLinkAboutF2016-0473 - Miscf2016.01473 ..... ... .._.,-.......-._.,.....- �,��., �1AC�r ijlr0w4........-„_-..,. DOCUMENTATION 72-39 SYSTEM RECORD OF COMPLETION This form is to be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this form as needed to provide a more complete and/or clear record. Insert N/A in all unused lines. Attach additional sheets, data, or calculations as necessary to provide a complete record. Form Completion Date: 10-15-19 Supplemental Pages Attached: PROPERTY INFORMATION Name of property: Hyatt Regency Newport Beach Address: 4545 MacArthur Blvd Newport Beach, Ca 92660 imeis.BwIding-Qnlp)- Description of property: _ Hotel aiadower floors3te,J- 1 Name of property representative: Elite Properties Address: 148 S. Beverly Green Dr. Suit 202 Beverly Hills Ca 90212 Phone: Fax: E-mail: 2. INSTALLATION, SERVICE, TESTING, AND MONITORING INFORMATION Installation contractor: Global Fire Technologies Inc Address: 313 E. Broadway #312 Glendale Ca 91209 Phone: 818-330-7136 Fax_ 818-330-7137 E-mail: Info@glofretech.com Service organization: N/A Address: N/A Phone: N/A Fax: N/A E-mail: N/A Testing organization: N/A Address: N/A Phone: N/A Fax: N/A E-mail: N/A Effective date for test and inspection contract: NIA Monitoring organization: Red Hawk Fire& Security Address: 1640 N. Batavia Street Orange, Ca Phone: 714685-800 Fax: Account number: Phone line 1: Means of transmission: Hard Wire Land Line Entity to which alarms are retransmitted: 3. DOCUMENTATION On-site location of the required record documents and site-specific software: 4. DESCRIPTION OF SYSTEM OR SERVICE This is a: ® New system ❑ Modification to existing system NFPA 72 edition: 2013 4.1 Control Unit Manufacturer: Edwards 4.2 Software and Firmware Firmware revision number: — 4.3 Alarm Verification Number of devices subject to alarm verification: ® 2015 National Fire Protection Association FIGURE 7.8.2(a) System Record of Completion. (SIG -FUN) E-mail: Phone line Permit number: F2016-0473 EBSt Tower Model number: EST3 W This system does not incorporate alarm verification. Alarm verification set for seconds NFPA 72 (p. 1 of 3) 2016 Edition n 72-40 NATIONAL FIRE ALART)d AND SIGNALING CODE SYSTEM RECORD OF COMPLETION (continued) S. SYSTEM POWER 5.1 Control Unit 5.1.1 Primary Power Input voltage of control panel: 11 o VAC Control panel amps: 20 AMP Overcurrent protection: Type: N/A Amps: N/A Branch circuit disconnecting means location: Main Electric room Number: 6 5.1.2 Secondary Power Type of secondary power: Battery Location, if remote from the plant: N/A Calculated capacity of secondary power to drive the system: In standby mode (hours): 24 In alarm mode (minutes): 15 5.2 Control Unit ❑ This system does not have power extender panels $i Power extender panels are listed on supplementary sheet A 6. CIRCUITS AND PATHWAYS Dual Media Separate Survivability Pathway Type Pathway Pathway Class Level Signaling Line X Device Power Initiating Device \ \ Notification Appliance Other (specify): 7. REMOTE ANNUNCIATORS Type Location LCD Lobby & Security room S. INITIATING DEVICES Addressable or Alarm or Sensing Type Quantity Conventional Supervisory Technology Manual Pull Stations 64 Addressable Alarm Smoke Detectors 624 Addre .. hl, Alarm er Duct Smoke Detectors 0 \ Heat Detectors 1 A dressable Alarm Gas Detectors Watertlow Switches 18Address ble halm Tamper Switches 20 supervisory ry ® 2015 National Fire Protection Association NFPA 72 (p. 2 of 3) FIGURE 7.8.2(a) Continued r 2016 Edition DOCUMENTATION 72-41 SYSTEM RECORD OF COMPLETION (continued) 9. NOTIFICATION APPLIANCES Type Quantity Description Audible 369 Speaker Visible 42 Strobe Combination Audible and Visible 170 5 eaker & Strobe 10. SYSTEM CONTROL FUNCTIONS Type Quantity Hold -Open Door Releasing Devices 40 HVAC Shutdown N/A Fire/Smoke Dampers A Door Unlocking NIA Elevator Recall 10 Elevator Shunt Trip 11. INTERCONNECTED SYSTEMS This system does not have interconnected systems. U Interconnected systems are listed on supplementary sheet 12. CERTIFICATION AND APPROVALS 12.1 System Installation Contractor This system as specified herein has been installed according to all NFPA standards cited herein. S&ae AgQgoomw"m Signed: Printed name: Steve Arezoomanian Date: 10-15-19 Organization: Global Fire Technalocies Inc Title: V.P Phone: 818-330-7136 12.2 System Operational Test This system as specified herein has tested according to all NFPA standards cited herein. Signed: S&ar firezeomanta Printed name: Steve Arezoomanian Date: 10-15-19 Organization:_ global Fire Technologies Inc Title: VR Phone: 818-330-7136 12.3 Acceptance Test Date and time of acceptance test: 10-15-192:00 PM Installing contractor representative: Steve Arezoomanian Testing contractor representative: Steve Arezoomanian Property representative: AHJ representative: © 2015 National Fire Protection Association NFPA 72 tp. 3 of 3) FIGURE 7.8.2(a) Continued 2016 Edition n NOTIFICATION APPLIANCE POWER PANEL SUPPLEMENTARY RECORD OF COMPLETION This form is a supplement to the System Record of Completion. It includes a list of types and locations of notification appliance power extender panels. This form is to be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this form as needed to provide a more complete and/orc/ear record. Insert N/A in all unused lines. Form Completion Date: 10/15/09 Number of Supplemental Pages Attached: 1 1. PROPERTY INFORMATION Name of property: Hyatt Regency Newport Beach Address: 4545 Macarthur Blvd Newpport Beach , Ca 92660 East Tower 2. NOTIFICATION APPLIANCE POWER EXTENDER PANELS See Main System Record of Completion for additional information, certifications, and approvals. Copyright ® 2012 National Fire protection Associalion. This form may be copied for individual use other Nan for resale. It may not be copied for commercial sale or distribution. (0 1 of 1) DOCUMENTATION SYSTEM RECORD OF COMPLETION This form is to be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this form as needed to provide a more complete and/or clear record. Insert N/A in all unused lines. Attach additional sheets, data, or calculations as necessary to provide a complete record. Form Completion Date: 3-15-19 Supplemental Pages Attached: 1. PROPERTY INFORMATION Name of property: Hyatt Regency Newport Beach Address:. 4545 MacArthur Blvd Newport Beach, Ca 92660 (Main Building Only) Description of property: Hotel Main tower floors 2 to 7 A (y[-( i o YA 1".°t q L if V IF L. Name of pmperty representative: Elite Properties Address: 148 S. Beverly Green Dr. Suit 202 Beverly Hills Ca 90212 Phone: Fax: E-mail: 2. INSTALLATION, SERVICE, TESTING, AND MONITORING INFORMATION Installation contractor: Global Fire Technologies Inc Address: 313 E. Broadway #312 Glendale Ca 91209 Phone: 818-330-7136 Fax: 818-330-7137 E-mail: Info@glofimtech.com Service organization: N/A Address: N/A _. Fax: N/A E-mail: N/A Testing organization: N/A Address: N/A Phone: NIA Fax: N/A E-mail: N/A Effective date for test and inspection contract: N/A Monitoring organization: Red Hawk Fire 8 Security Address: 1640 N. Batavia Street Orange, Ca Phone: 714-685-800 Fax: E-mail: Account number. Phone line 1: Phone line 2: Entity to which alarms are retransmitted:. Phone: 3. DOCUMENTATION On-site location of the required record documents and site-specific software: 4. DESCRIPTION OF SYSTEM OR SERVICE O 1 —0� ��1� This is a: IID New system 0 Modification to existing system Permit number: , 1 NFPA 72 edition: 2013 4.1 Control Unit Manufacturer: Edwards Model number: EST3 4.2 Software and Firmware Firmware revision number: 01.00 4.3 Alarm Verification M This system does not incorporate alarm verification. Number of devices subject to alarm verification: Alarm verification set for seconds ® 2015 National Fire Protection Association NFPA 72 (p.1 of 3) FIGURE 7.8.2(a) System Record of Completion. (SIG -FUN) 2016 Edition IN 72-40 NATIONAL FIRE ALARM AND SIGNALING CODE SYSTEM RECORD OF COMPLETION (continued) 5. SYSTEM POWER 5.1 Control Unit 5.1.1 Primary Power Input voltage of control panel: do VAC Control panel amps: 20 AMP Overcurrent protection: Type: N/A Amps: N/A Branch circuit disconnecting means location: Main Electric room Number: 6 5.1.2 Secondary Power Type of secondary power: Battery Location, if remote from the plant: N/A Calculated capacity of secondary power to drive the system: In standby mode (hours): 24 In alarm mode (minutes): 15 5.2 Control Unit O This system does not have power extender panels 0 Power extender panels are listed on supplementary sheet A 6. CIRCUITS AND PATHWAYS Dual Media Separate Survivability Pathway Type Pathway Pathway Class Level Signaling Line X Device Power Initiating Device \ \ Notification Appliance Other (specify): 7. REMOTE ANNUNCIATORS Type Location LCD Lobby 8 Security room 8. INITIATING DEVICES Addressable or Alarm or Sensing Type Quantity Conventional Supervisory Technology Manual Pull Stations 64 Addressable Alarm Smoke Detectors 624 Duct Smoke. Detectors0 \ Heat Detectorsa Addressable, Alarm Gas Detectors Waterflow Switches gAddresnable Alarm Tamper Switches g rarrglahle Su ervlso ® 2015 National Fire Protection Association NFPA 72 (p.2 of 3) FIGURE 7.8.2(a) Continued W 2016 Edition DOCUMENTATION 72-41 SYSTEM RECORD OF COMPLETION (continued) 9. NOTIFICATION APPLIANCES Type Quantity Description Audible 369 Speaker Visible 42 Strobe Combination Audible and Visible 170 Speaker & Strobe 10. SYSTEM CONTROL FUNCTIONS Type Quantity Hold -Open Door Releasing Devices 50 HVAC Shutdown N/A Fire/Smoke Dampers Door Unlocking NIA Elevator Recall 16 Elevator Shunt Trip 11. INTERCONNECTED SYSTEMS * This system does not have interconnected systems. ❑ Interconnected systems are listed on supplementary sheet 12. CERTIFICATION AND APPROVALS 12.1 System Installation Contractor This system s spec' ted herein has been installed according to all NFPA standards cited herein. 1 Signed: .__ Printed name: Steve Arezoomanian Date: 03-15.19 Organization: Global Fire Technologies Inc Title: V.P Phone: 816-330-7136 122 System Operational Test This system as spe j ed erein has tested according to all NFPA standards cited herein. Signed: _ Printed name: Steve Arezoomanian Date: n3-15-19. Organization: Global Fire Technologjes Inc. Title: _ V -P Phone: 616-330-7136 12.3 Acceptance Teat Date and time of acceptance test: D3-15-192:00 PM Installing contractor representative: Steve Arezoomanian Testing contractor representative: Steve Arezoomanian Property representative: AHJ representative: ® 2015 National Fire Protection Association NFPA 72 (p. 3 of 3) FIGURE 7.8.2(x) Continued 2016 Edition rx NOTIFICATION APPLIANCE POWER PANEL SUPPLEMENTARY RECORD OF COMPLETION This form is a supplement to the System Record of Completion. It includes a list of types and locations of notification appliance power extender panels. This form is to be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this form as needed to provide a more complete andlor clear record. Insert WA in all unused lines. Form Completion Date: 1. PROPERTY INFORMATION 03/15/19 Name of property: Hyatt Regency NewPort Beach Address: 4545 Macarthur Blvd Newpport Beach , Ca 92660 Number of Supplemental Pages Attached: 2. NOTIFICATION APPLIANCE POWER EXTENDER PANELS See Main System Record of Completion for additional information, certifications, and approvals. Copydght C 2012 National Fire Protection Association. This form maybe copied for individual use other then for resale. It may not be copied for commercial sale or distribution. (p. 1 of 1)