HomeMy WebLinkAboutX2019-1804 - MiscContinuous Inspection & Materials Testing SOUT ST ®vvr®®®��®®s®®®® 1118jwctioll & restilig, 111C• 441 Commcrcial Way, La Habra, CA 90631-6165 (562)941-2990 - (714)526-5441 FAX (562)946-0026 FIELD DATA ON TEST SPECIMENS X2Ojq - B8oU 1sa9,3kyjarktri --- ASTM C31, C138, C143, C172, C173, C231, C1064 --- CONCRETE: X MORTAR: SHOTCRETE: CORES: GUNITE: ADDRESS: 1628 SKYLARK, NEWPORT BEACH JOB #: DATE: 01/14/2019 JOB NAME: COPPOLA PERMIT #: X2018-3220 ISSUED BY: ARCHITECT: ENGINEER: SHAWN NIKJOO CONTRACTOR: MGS CONSTRUCTION SUB: A & B CONCRETE SERVICES LOCATION IN STRUCTURE: SLAB - MIDDLE TRACT: PHASE: LOT #: CONCRETE SUPPLIER: BENDER RDY MX PLANT: MIX #: 71/2 -1 TYPE OF CEMENT: V ADMIXTURE: TICKET #: SAI 7279 SLUMP: 0.00 in. WATER ADDED: 0 gal. AIR TEMP: 0 F CONCRETE TEMP: MIXING TIME: TIME CAST: 07:45 DATE CAST: 12/10/2018 RECEIVED AT LAB: 12/19/2018 SPECIMENS MADE BY: KELLY LUIZ SPECIFIED PSI @ 28 Days: 4500 LAB #: 131536 CLIENT: RICHARD LUIZ TESTING INFORMATION: SAMPLE IDENTIFICATION: 1785740 1785741 1785742 AGE DAYS: 28 28 28 DATE TEST: 01/07/2019 01/07/2019 01/07/2019 SIZE (in.): Height X Diameter 8.000 X 4.000 8.000 X 4.000 8.000 X 4.000 AREA (in.A): 12.57 12.57 12.57 CRUSH LOAD (lbs.): 58930 58210 58600 COMPRESSIVE STRENGTH (psi.): 4690 4630 4660 HEIGHT -DIAMETER RATIO: CORRECTION FACTOR: CORRECTED STRENGTH (psi.): BREAK TYPE: III III III C.T.M. USED: Forney96 Forney96 Forney96 REMARKS: ASTM C39, C174, C192, C470, C617, C42 COMPLIES: X DOES NOT COMPLY: FOR INFORMATION: THIS REPORT SHALL NOT BE REPRODUCED, EXCEPT IN FULL, WITHOUT THE APPROVAL OF SOUTHWEST INSPECTION AND TESTING, INC. SAMPLES CAST BY OTHERS: NOTICE:These test results are from samples cast by inspectors or technicians not employed by our firm. They were either delivered to our laboratory or picked up by our driver. We will accept no responsibility for the inspection made on the jobsite by the inspector, furthermore we do not take responsibility for any information on this report other than the strength as tested and reported. RESPECTFULLY SUBMITTED SOUTHWEST INSPECTION AND TESTING �� ASTM C39 BREAKS: 1=CONE - ll=CONE AND SPLIT - III=COLUMNAR - IV --SHEAR - V --SIDE FRACTURES - VI=POINTED Project Name & Address Inspection Type(s) Inspection Date(s) Inspection List Tests Made: Report of Special Inspection la- /h -/ including Locatins: Total Inspection Time Each Day: Date /"-/U- HoursHours [ ] Periodic [ Y, ] Continuous List Items Requiring Correction, include uncorrected items previously listed Comments: To the best of my knowledge, the work inspected was in accordance with the Building Department approved design drawings, specifications and applicable workmanship provisions of the U.B.C. except as noted above. l Signed: �� (i c �"L� , Date 1.2 !O J 1f 1 1l Print Full Name: 1'izbi W' Registration No. X11" ' - CONCR_TE FORM sl -0?; 9J .� ,caivn �from r"Y1(55 Ca-rii7acU-i PCAJYKA�, eLLIaDE COPPoLA-