April 24, 2019
Report emailed to: kawalker34@yahoo.com
Pool and or Spa Noise report for residence at 15 Tiburon Bay, Corona Del Mar, CA
Dear Homeowner:
At about 10:00 a.m. Wednesday, April 24, 20191 measured the pool and or spa equipment
noise at your nearest neighbor's residence to test for compliance with the Newport Beach noise
regulation (10.26.025).
Newport Beach Residential Noise Standard
For Noise Zone 1 (residential) the N. B. regulation's daytime noise level standard (maximum
noise level from 10 p.m. to 7 a.m.) is 55 dBA— corrected for ambient noise. The nighttime noise
standard (max noise level from 7 a.m. to 10 p.m.) is 50 dBA. The measurement is corrected for
ambient noise and rounded to the nearest decibel as shown below.
Measured pool and or spa apparatus noise meet the Newport Beach noise standard fordaytime
use only. A timer must be installed on the pool apparatus to restrict use to from 7 a.m. to 10 p.m.
Locations and values of daytime noise measurements
Uncorrected pool and or spa noise + ambient noise measured at property line: 55.53 dBA
Ambient noise level measured at this location: 47.80 dBA
Pool and or spa equipment noise corrected for ambient noise: 54.73 dBA
Pool and or spa equipment noise rounded to the nearest decibel: 55 dBA
55 dBA (Pass for daytime use only)
The currently installed pool and or spa apparatus noise of 55 dBA meets the Newport Beach
noise code for daytime" use only (7 a.m. to 10 p.m.) since the noise corrected for ambient
exceeds 50 dBA.
If you have any questions about this report, please do not hesitate to contact me at (714) 373-
3050 or by email at dlubman(a�dlacoustics.com
Sincerely yours,
.CJQN'ld L.iT'1AWYI.
David Lubman, FASA, FINCE
Acoustical Consultant
Orange County Certification #200524
April 24, 2019
APPENDIX A:
Measurement Instrumentation
Equipment
The acoustical equipment used in the performance of this test is in accordance with
ASTM and ANSI (American National Standards Institute) requirements. Key elements
are as follows:
Critical sound measuring instruments (sound analyzer, calibrator, and microphone) are
annual calibrated by an independent NAVLAP certified laboratory. The most recent
calibration was on 08/01/18. All calibration documents are available for inspection upon
request.
Critical instruments employed were:
Bruel & Kjaer— Type 2270 Type I Precision Sound Analyzer SN # 3002720
Bruel & Kjaer - Type 4189 microphone, SN # 2850866
Bruel & Kjaer—Type 4231 Field Sound Calibrator, SN # 2588671
DL Acoustics
14301 Middletown Lane Westminster, CA 92683
Res wchACa7sr%!e6) fr7AIca(661ts Voice/Fax 714.373.3050 dlubman@dlacoustics.com
April 24, 2019
Receipt for $350 Payment in Full
One Pool and or Spa Sound Test for homeowner at 15 Tiburon Bay, Corona Del Mar on 4/24/19
Check 2531 received from Keith A. Walker dated 4/24/19
David Lubman
DL Acoustics
EIN 33-0246903
Thanks for your business!