HomeMy WebLinkAboutX2019-2381 - Alternative Material & Methods (2)�4a wPoRr N CITY OF NEWPORT BEACH
ra o�
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING DIVISION
og41
FORNvf 100 Civic Center Drive I P.O. Box 1768 1 Newport Beach, CA 92658-8915
>* www.newportbeachm.gov 1 (949) 644-3200
CASE NO.:
❑ REQUEST FOR MODIFICATION TO PROVISIONS
OF TITLE 9 (FIRE CODE) OR TITLE 15 (BUILDING CODE)
OF THE NEWPORT BEACH MUNICIPAL CODE
(See Reverse for Basis for Approval) (Fee $294)
® REQUEST FOR ALTERNATE MATERIAL
OR METHOD OF CONSTRUCTION
(See Reverse for Basis for Approval) (Fee $294)
❑ REQUEST FOR EXEMPTION FROM DISABLED
ACCESS DUE TO PHYSICAL OR LEGAL
CONSTRAINT (Fee $1,637)
(Ratification by the Board of Appeals will be required.)
For above requests, complete Sections 1, 2 & 3
below by printing in ink or typing.
JOB ADDRESS:
•
Ccrt.111U .ITv
OCT V) "wa
c DEVELCPWL:NT S•
:.f J
IIII FOR STAFF USE ONLY III
Plan Check # I
( # of `ytories -�
Occupancy Classification
2i/
Use of Building
:1" C #�s
Project Status L
Construction Type
--�-
Verified by
No. of Items
Feedue
DISTRIBUTION:
Owner
rClf�
Plan Check ,-`6—
Petitioner
Inspector
Fire
❑ Other
SITE ADDRESS: 313 Heliotrope Avenue, Corona Del Mar Petitioner Famed Manshadl
Owner Mitch&Julie Hill (Pefitloner to be amhttect or engineer)
Address 313 Heliotrope Avenue, Address 1800 E. 16th St., Unit B
Corona Del Mar, CA Zip 92625 Santa Ana, CA Zip92701
Daytime Phone ( 774) 83&2800
Daytime Phone ( 949)-5849994
IKEQUEST: Submit plans if necessaryto illustrate request. Additional sheets or data may be attached. 11
The coal tar epoxy will provide equivalent protection for the soldier beams as the concrete. ACI 318-10.136.8 ACI 318-7.7.1
Also from a constructabirty standpoint the concrete ran not be chlpped out from around the soldier beam flanges to install the timber
lagging and Nelson studs that support the final shortcrete facing. This procedure was used successfully at 3431 Ocean Blvd.,
2011 Kings Road, 1410 Kings Road, 1201 Dolphin Terrace in Newport.
Petitioners / Position Vice President
Signature CA Professional Lic. # CE 36640 Date 1 0/2 912 01 9
FOR STAFF USE ONLY it
DEPARTMENT ACTION: In accordance with: ❑ CBC 104.11/CFC 104.9 ❑ CBC 104.101CFC 104.8
(Alternate materials & methods) (CBC Modification)
❑ Concurrence from Fire Code Official is required. ❑ Approved ❑ Disapproved ❑ Written Comments Attached
❑ Request (DOES) (DOES NOT) lessen any fire protection requirements.
❑ Request (DOES) (DOES NOT) lessen the structural integrity
The Request is Granted ❑ Denied (See reverse for
❑ Granted (Ratification required) appeal information)
Signature `
Print Name
APPEAL OF DIVISION ACTION TO THE BUILDING BOARD OF APPEALS (See Reverse)
(Signature, statement of own IcanI. t ment of reasc for appeal and filing fees are required.)
CASHIER RECEIPT NUMBER: IVV��I11166 /�J `//Vn Fmmstrnadif 09/21/18
�
■
�
;
7
§
r
�
�
E.
r
K |f
2
g
C,j
".
rcorsliugs -Linings - Firnpiroofirsg
SELECTION & SPECIFICATION DATA
Generic Type I Coal -tar epoxy polyamide
Bitumastic® 300 M
PRODUCT DATA SHEET
DescriptionI Renowned high build coal tar epoxy polyamide for protection of steel and concrete in single or two -
coat applications in a broad variety of aggressive industrial applications.
• Excellent chemical, corrosion and abrasion resistance
• High -build, 16-24 mils (400-610 microns) in a single coat (up to 35 mils with force curing)
• Compatible with controlled cathodic protection
Features ' Suitable for use in exposures as referenced in the following specifications:
• Corp of Engineers C-200, C200a
• AW WA C-210 for exterior
• SSPC-Paint 16
• Steel Tank Institute Corrosion Control System STI -P3
Color Black P900
Red P500
Primer I Self -priming, or use suitable prime as recommended by Carboline.
16 mils (406 microns) in one or two coats
Dry Film Thickness Total dry film thickness in excess of 35 mils (875 microns) is not recommended. Wet -on -wet spray
techniques should be used for high thicknesses allowing time for solvents to flash between passes.
Solids Content I By Volume 74%+/- 2%
1187 ft'/gal at 1.0 mils (29.1 m2/I at 25 microns)
Theoretical Coverage 74 ft2/gal at 16.0 mils (1.8 m'/1 at 400 microns)
Rate Allow for loss in mixing and application.
As Supplied : 1.85 lbs/gal 222 g/I
Thinner 10 : 10 oz/gal: 2.2 lbs/gal 269 g/I
VOC Values These are nominal values.
Thinner 10: 25 oz/gal: 2.7 lbs/gal 327 g/1
*Maximum thinning for 250 g/I restricted areas is 6 oz/gal.
Dry Temp. Resistance Continuous: 350'F (177°C)
Non -Continuous: 370'F (188°C)
Limitations I Do not use for potable water requirements.
Topcoats I Not recommended
Wet Temp. Resistance I Immersion temperature should not exceed 120'F (49°C)
SUBSTRATES & SURFACE PREPARATION
GeneralI Surfaces must be clean and dry. Employ adequate methods to remove dirt, dust, oil and all other
contaminants that could interfere with adhesion of the coating.
June 2019 0165 Page 1 of 4
Bitumastic® 300 M CbOliile
PRODUCT DATA SHEET
SUBSTRATES & SURFACE PREPARATION
Immersion: SSPC-SP10
Steel Non -Immersion: SSPC-SP6
SSPC-SP2 or SP3 as minimum requirement.
Surface Profile: 2.0-3.0 mils (50-75 micron)
Concrete must be cured 28 days at 75*F (24°C) and 50% relative humidity or equivalent. Prepare
Concrete or CMU surfaces in accordance with ASTM D4258 Surface Cleaning of Concrete and ASTM D4259
Abrading Concrete. Voids in concrete may require surfacing.
PERFORMANCE DATA
Test Method
System
Results
No blistering, rusting or delamination.
ASTM 8117 Salt Fog
Blasted Steel 2 cts. 300M
No measurable undercutting
at scribe after 2000 hours
ASTM D2794 Impact
Blasted Steel 2 cts. 300M
Impact site diameter, Inches: 3/8,3/8, 1/2
100 in/lbs Gardner Impactor at 1/2 in. diam.
ASTM D4060 Abrasion
Blasted Steel 2 cts. 300M
130 mg. loss after 1000 cycles,
CS17 wheel, 1000 gm load
ASTM D4541 Adhesion
Blasted Steel 2 cts. 300M
1443 psi (Pneumatic)
Test reports and additional data available upon written request. *Disclaimer: Bitumastic 300M is a proprietary formula that is not
necessarily formulated to the exact compositional guidelines set forth in some of these standards. Minor deviations that control and
improve application characteristics may be present, but does not have a detrimental effect on the suitability for use outlined therein.
MIXING & THINNING
Mixing Power mix separately, then combine and power mix for a minimum of two minutes. DO NOT MIX
PARTIAL KITS.
Up to 10 oz/gal (8%) w/ #10
Thinning Up to 25 oz/gal (20%) w/ #10 for the first coat application to concrete.
Use of thinners other than those supplied or recommended by Carboline may adversely affect
product performance and void product warranty, whether expressed or implied.
Ratio 14:1 Ratio (A to B)
75°F (24°C) 2 Hours
Pot Life 90°F (32°C)1 Hour
Pot life ends when coating loses body and begins to sag.
APPLICATION EQUIPMENT GUIDELINES
Listed below are general equipment guidelines for the application of this product. Job site conditions may require modifications
to these guidelines to achieve the desired results_
Spray Application This isa high solids coating and may require adjustments in spray techniques. Wet film thickness
(
P y is easily and quickly achieved. The following spray equipment has been found suitable and is
(General) available from manufacturers such as Binks, DeVilbiss and Greco.
Conventional SprayI Pressure pot equipped with dual regulators, 3/8" I.D. minimum material hose, with 50' maximum
material hose .086" I.D. fluid tip and appropriate air cap.
June 2019 0165 Page 2 of 4
Comings-Linings-Fimpro f..g
APPLICATION EQUIPMENT GUIDELINES
Bitumastic® 300 M
PRODUCT DATA SHEET
Listed below are general equipment guidelines for the application of this product. Job site conditions may require modifications
to these guidelines to achieve the desired results.
Airless Spray
Pump Ratio: 30:1'
GPM Output: 3.0 (min.)
Material Hose: %' I.D. (min.)
Tip Size: .023-.035"
Output PSI: 2100-2500
Filter Size: 30 mesh
"Teflon packings are recommended and available from the pump manufacturer.
Brush & Roller Recommended for touch up, striping of weld seams and hard -to -coat areas only. Avoid excessive
(General) re -brushing or re -rolling.
Brush I Use a medium bristle brush.
Roller I Use a short -nap synthetic roller cover with phenolic core.
APPLICATION CONDITIONS
Condition
Material
Surface
Ambient
Humidity
Minimum
50°F (10°C)
50°F (10°C)
50°F (10°C)
0%
Maximum
90°F (32°C)
125°F (52°C)
110°F (43°C)
90%
Condensation due to substrate temperatures below the dew point can cause flash rusting on prepared steel and interfere with
proper adhesion to the substrate. Special application techniques may be required above or below normal application conditions.
CURING SCHEDULE
Surface Temp.
Dry to Touch
Minimum Recoat Time
Maximum Recoat Time
Final Cure Immersion
50°F (10°C)
6 Hours
10 Hours
24 Hours
14 Days
75°F (24°C)
4 Hours
6 Hours
24 Hours
7 Days
90°F (32°C)
2 Hours
3 Hours
24 Hours
5 Days
These times are based on a 16.0 mil (400 micron) dry film thickness. Higher film thickness, insufficient ventilation, high humidity or
cooler temperatures will require longer cure times. Excessive humidity or condensation on the surface during curing can interfere
with the cure, can cause discoloration and may result in a surface haze. Any haze or blush must be removed by water washing
before recoating. If the maximum recoat time is exceeded, the surface must be abraded by sweep blasting prior to the application
of additional coats. Holiday Detection (if required): Wet sponge types may be used if the dry film thickness is below 20 mils (500
microns). High voltage spark testing should be used when the dry film thickness exceeds 20 mils (500 microns). Refer to the latest
version of NACE SP0188 for specific procedures.
Force curing at 150 F is an acceptable method to accelerate cure.
Cleanup Use #2 Thinner or Acetone. In case of spillage, absorb and dispose of in accordance with local
applicable regulations.
Read and follow all caution statements on this product data sheet and on the SDS for this product.
Safety Employ normal workmanlike safety precautions. Hypersensitive persons should wear protective
clothing, gloves and use protective cream on face, hands and all exposed areas.
June 2019 0165 Page 3 of 4
Bitumastic® 300 M
PRODUCT DATA SHEET
CLEANUP & SAFETY
roatLlgs - Lirr irgs - Firepro oJing
This product contains flammable solvents. Keep away from sparks and open flames. All electrical
Caution equipment and installations should be made and grounded in accordance with the National Electric
Code. In areas where explosion hazards exist, workers should be required to use non-ferrous tools
and wear conductive and non -sparking shoes.
PACKAGING. HANDLING & STORAGE
Shelf Life
Part A: Min. 24 months at 75*F (24°C)
Part B: Min. 36 months at 757 (24°C)
*Shelf Life: (actual stated shelf life) when kept at recommended storage conditions and in original
unopened containers.
Storage Temperature & 40° -110*F (4* -43°C)
Humidity 0-100% Relative Humidity
Storage I Store indoors
Shipping Weight 11.25 Gallon Kit - 12 lbs (6 kg)
(Approximate) 5 Gallon Kit - 50 lbs (26 kg)
Flash Point (Setaflash) Part A: 75°F (24°C)
Part B: >200°F (93°C)
WARRANTY
To the best of our knowledge the technical data contained herein is true and accurate on the date of publication and is subject
to change without prior notice. User must contact Carboline Company to verify correctness before specifying or ordering. No
guarantee of accuracy is given or implied. We guarantee our products to conform to Carboline quality control. We assume no
responsibility for coverage, performance, injuries or damages resulting from use. Carbolines sole obligation, if any, is to replace
or refund the purchase price of the Carboline product(s) proven to be defective, at Carbolines option. Carboline shall not be liable
for any loss or damage. NO OTHER WARRANTY OR GUARANTEE OF ANY KIND IS MADE BY CARBOLINE, EXPRESS OR
IMPLIED, STATUTORY, BY OPERATION OF LAW, OR OTHERWISE, INCLUDING MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE. All of the trademarks referenced above are the property of Carboline International Corporation unless
otherwise indicated.