HomeMy WebLinkAboutM2019-0030 - MiscM)019-0030
5 Collis isle
Report of Special Inspection
Project Name & Address Cory Thabit Boat Dock, #5 Collins
Permit Number M2019-0030
Inspection Type(s) Epoxy
Inspection Date(s) 9-10-19 Periodic ❑I Continuous
Describe Inspection Made, including locations:
Epoxy
Observed the installation of threaded rods into the existing concrete using
Simpson xp epoxy, expiration 2020. Verified the hole depths and proper cleaning
with a nylon brush and compressed air prior to the epoxy. Per schedule and
details on the approved plan. Detail on S-4 / K
Locations:
1) Detail on 8-4 / K
A) Pile #1 and Pile #2 with (2) 5/8" threaded rods with min. 6" embed. Per Pile
2) S-4 / T = (N) 4x8 Ledger with 5/8" rods @ 16" o.c with min. 6" embed.
Work is complete for the areas listed.
List Tests Made
Total Inspection Time Each Day:
List Items Requiring Correction, Include Uncorrected Items Previously Listed:
To the best of my knowledge, the work inspected was in accordance with the Building Department
approved design drawings, specifications and applicable workmanship provisions of the IDC except as
noted above.
9-10-19
Print Pryil Nine: Jon Newsom Registration No. NB -0303
rowx Wr2'zoia
Report of Special Inspection
Project Name&Address Conrad -Patterson Custom Home -#5 Collins Island
Permit Number M2019-0030
Inspection Type(s) Marine Piles
Inspection Date(s) 09-06-19 Periodic❑✓ Continuous
Describe Inspection Made, including locations:
Marine Piles
Scope of work to replace (2) two existingl4" Sq. T -Piles concrete piles as shown
on Pg S-3 on approved plans. Numbered 1 & 2 for easy reference.
Piles numbered and listed on Pile Schedule Pg S-3. Detail V - Pile 1 & 2
3'x0" 14" Sq. T -Pile 30' long.
TX0" 14" Sq. T -Pile 30' long
Observed the placement of the (2) T -piles - minimum embedment of 15' met for
each pile.
Work is complete for each pile location.
List Tests Made
Total Inspection Time Each Day:
Date
Hours)
List Items Requiring Connection, Include Uncorrected Items Previously Listed:
To the best of my knowledge, the work inspected was in accordance with the Building Department
approved design dr Ings, specifications and applicable workmanship provisions of the IDC except as
noted above. /�
Z' iJ . A _ 09-06-19
Print Full Name: U Tracy D.Barr Registration No. NB -0711