Loading...
HomeMy WebLinkAboutM2019-0030 - MiscM)019-0030 5 Collis isle Report of Special Inspection Project Name & Address Cory Thabit Boat Dock, #5 Collins Permit Number M2019-0030 Inspection Type(s) Epoxy Inspection Date(s) 9-10-19 Periodic ❑I Continuous Describe Inspection Made, including locations: Epoxy Observed the installation of threaded rods into the existing concrete using Simpson xp epoxy, expiration 2020. Verified the hole depths and proper cleaning with a nylon brush and compressed air prior to the epoxy. Per schedule and details on the approved plan. Detail on S-4 / K Locations: 1) Detail on 8-4 / K A) Pile #1 and Pile #2 with (2) 5/8" threaded rods with min. 6" embed. Per Pile 2) S-4 / T = (N) 4x8 Ledger with 5/8" rods @ 16" o.c with min. 6" embed. Work is complete for the areas listed. List Tests Made Total Inspection Time Each Day: List Items Requiring Correction, Include Uncorrected Items Previously Listed: To the best of my knowledge, the work inspected was in accordance with the Building Department approved design drawings, specifications and applicable workmanship provisions of the IDC except as noted above. 9-10-19 Print Pryil Nine: Jon Newsom Registration No. NB -0303 rowx Wr2'zoia Report of Special Inspection Project Name&Address Conrad -Patterson Custom Home -#5 Collins Island Permit Number M2019-0030 Inspection Type(s) Marine Piles Inspection Date(s) 09-06-19 Periodic❑✓ Continuous Describe Inspection Made, including locations: Marine Piles Scope of work to replace (2) two existingl4" Sq. T -Piles concrete piles as shown on Pg S-3 on approved plans. Numbered 1 & 2 for easy reference. Piles numbered and listed on Pile Schedule Pg S-3. Detail V - Pile 1 & 2 3'x0" 14" Sq. T -Pile 30' long. TX0" 14" Sq. T -Pile 30' long Observed the placement of the (2) T -piles - minimum embedment of 15' met for each pile. Work is complete for each pile location. List Tests Made Total Inspection Time Each Day: Date Hours) List Items Requiring Connection, Include Uncorrected Items Previously Listed: To the best of my knowledge, the work inspected was in accordance with the Building Department approved design dr Ings, specifications and applicable workmanship provisions of the IDC except as noted above. /� Z' iJ . A _ 09-06-19 Print Full Name: U Tracy D.Barr Registration No. NB -0711 FORM SL02, 3014