HomeMy WebLinkAboutF2019-0481 - MiscF.gujv- U'161 660/ Avocado Acre CONTRACTOR'S MATERIAL & TEST CERTIFICATE FOR UNDERGROUND PIPING Procedure Upon completion of work, inspection and tests shall be made: by contractor's representative and witnessed by an owner's representative. All defects shall be corrected and system left in service before contractor'spersonnel finally leave job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities, owners and contractor. Itis understood the owner's representative's signature in no way prejudices any claim againstcontractor for faulty material, poor workmanship,or failure to comply with approving authority's requirements or local ordinances. rnvrU, r ,vnrv,c City Of Hope I un, -12/5/19 rMUMM I r rruurtcaa 1601 Avocado Ave. NewportBeachGA. S e, -r PE PE ACCEPTED BY APPROVING AUTHORITY('S) NAMES Newport Beach Fire Dept ADDRESS 100 Civic Center Dr, Newport Beach 92660 PLANS. INSTALLATION CONFORMS TO ACCEPTED PLANS -,� YES ❑ NO EQUIPMENT USED 15 APPROVED e—YES ❑ NO IF NO. STATE DEVIATIONS: HAS THE PERSON IN CHARGE OF FIRE EQUIPMENT BEEN INSTRUCTED AS TO LOCATION ?c:�i'ES ❑ NO OF CONTROL VALVES AND CARE AND MAINTENANCE OF THIS NEW EQUIPMENT. IF NO; EXPLAIN INSTRUCTIONS ---- HAVE COPIES OF APPROPRIATE INSTRUCTIONS AND CARE AND MAINTENANCE CHARTS i?'i'ES ❑ NO BEEN LEFT ON THE PREMISES. IF NO, EXPLAIN SUPPLIES SLOGS. 1601 Avocado Ave. LOCATION PIPE TYPES. AND; CLASS C900& Ductile Iron TYPE JOINT MJ PIPE CONFORMS TO NFPA 24 STANDARD T -YES ❑ NO UNDERGROUND FITTINGS CONFORM TO NFPA.24 STANDARD 7CQ'ES ❑ NO PIPES IF NO, EXPLAIN AND JOINTS JOINTS NEEDING ANCHORAGE CLAMPED, STRAPPED OR BLOCKED IN ',O_ YES ❑ NO ACCORDANCE WITH NEPA 24 STANDARD IF NO, EXPLAIN FLUSHING- Flow the required rate until water is clear as indicated by no collection of foreign material in burlap begs at outle such as hydrants and blow -offs. Flush atflows not less than 400 gpm (1514 Ilmin) for 4 -inch pipe 600 gpm (2271 I/min) for! inch pipe, 900 gpm (28391/min) for 6 -Inch pipe, 1600 gpm (3786 I/min) for 8 -Inch pipe, 2440 gpm (5678 Itmin) for 10 -inch pip and 3520 gpm (75701/min)for 12 -inch pipe. When supply cannotproduce: stipulated flow rates, obtain maximum available. TEST HYDROSTATIC: Hydrostatic tests shall be made at hot less than 200 psi (13,8 bars)for two hours or 50 psi (3.4 bars) above DESCRIPTION static pressure in excess of 150 psi (10.3 bars) for two hours. LEAKAGE, New pipe fold with rubber gasketed joints. shall, If the workmanship is satisfactory, have little or no leakage at the joints. The amount of leakage at the joints shall not exceed 2 qts;perhr (1.591/h) per 100 joints Irrespective of pipe diameter. The leakage shall be distributed over all joints. If such leakage occurs at a few joints the installation shall be considered unsatisfactory and necessary, repairs made. The amount of allowable leakage specified above may be Increased by 1 fi oz P In. valve diameter per hour (30 mt125 mm/h) for each metal seated valve Isolating the test section. If dry barrel hydrants are tested with the main valve open, so the hydrants are under pressure, an additional 5 o7Jmin leakage Is permitted for each hvdrant NEW UNDERGROUND PIPING FLUSHED ACCORDING TO NFPA 24 STANDARD `,-YES ❑ NO BY: (COMPANY) Muir Chase Plumbing IF NO, EXPLAIN HOW FLUSHING FLOW WAS OBTAINED THROUGH WHAT TYPE OPENING FLUSHING TESTS E PUBLIC MAIN ❑ TANK OR RESERVOIR ❑ FIRE PUMP ❑ HYDRANT BUTT 9 OPEN P - LEAD-INS FLUSHED ACCORDING TO . STANDARD -OYES ❑ NO BY: (COMPANY) Muir Chasc Plumbing FN N HOW FLUSHING FLOW WAS OBTAINED THROUGHWHATTYPE OPENING E PUBLIC MAIN ❑ TANK OR RESERVOIR ❑ FIRE PUMP ❑ Y CONN TO FLANGE & SPIGOT N OPEN P S e, -r PE PE HYDROSTATIC ALL NEW UNDERGROUND PIPING HYDROSTATICALLY TESTED AT TESTS M PSI FOR u HOURS Yes TOTAL AMOUNT OF LEAKAGE MEASURED LEAKAGE GALS. OVER ++ HOURS TEST ALLOWABLE LEAKAGE GALS. OVER HOURS NUMBER INSTALLED TYPE AND MAKE ALL OPERATE SATISFACTORILI HYDRANTS 0 ❑ YES ❑ NO WATER CONTROL VALVES LEFT WIDE OPEN YES ❑ NO CONTROL IF NO, STATE REASON VALVES- HOSE THREADS OF FIRE DEPARTMENT CONNECTIONS AND HYDRANTS INTERCHANGEABLE WITH THOSE OF FIRE DEPARTMENT ANSWERING ALARM YES ❑ NO DATE LEFT IN SERVICE REMARKS 10/22/19 NAME OF INSTALLING CONTRACTOR Muir Chase Plumbing PRIORITY FIRE PROTECTION INC. TESTS WITNESSED BY AdaM Shade SIGNATURES FOR PROPERTY�O NER (�_ „SIGNED) TITLE Owners Representative DATE 12/5/19 FOR INST�LLIhiG G �N7RACTOR (SIG(SIGNED) TITLE Project Manager DATE12/5/19' ADDITIONAL EXPLANATIONS AND NOTES