HomeMy WebLinkAboutX2019-2024 - MiscLEO BURKE ENGINEERING, INC. 34167 Pacific Coast Highway, Suite D • Dana Point, CA 92629 PHONE: (949) 226-7130 Re: Horioka Residence 724 St James Place Newport Beach, CA Date: August 26, 2019 Subject: Caisson (Pier Footing) Field Condition To Whom It May Concern: Voaq-)04 W4 5d504mes This letter has been written at the request of the contractor at the Horioka residence regarding the caisson footing. During construction, a lateral pipe was discovered to bisect horizontally through the new pier footing. After the geologist approved the footing depth and bearing capacity, the contractor sleeved the existing horizontal pipe and provided the necessary vertical bars. Incidentally the diameter of the caisson improved from 24" to 30" in diameter for the entire depth. If there are any other questions or concerns, please call me at (949) 226-7130. Sincerely, Leo Burke, PE P• COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 505 Forest Avenue I Laguna Beach, CA 92651 SMOKE DETECTOR AND CARBON MONOXIDE SELF CERTIFICATION This Certification is to be rifted out by Nae Parmittoo Project Address: r � � 2'�j�� 1 �AiC 9 U )pU! I 6pbu� Permit Number: a Property Owner. rvyf-, (] Licensed Contractor: Lic #: I, the undersigned, hereby certify that I am the permittee of the project. I further certify that smoke alarms and carbon monoxide alarms are present and tested to be functional in all the following locations: California Residential Code (CRC) Section R314.1, CRC R315.2 states in part that existing dwellings be "retrofltted with smoke detectors and carbon monoxide detectors when a building permit is issued for, work or repairs to a building that is valued at $1,000 or more." CRC Section R314.3, CRC 8315.3 defines required locations. Bothboxes below must be checked. `, Carbon Monoxide Alarm: On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms or in each hallway outside of the rooms, and each level of the dwelling. Smoke Alarms: Installed in each room used for sleeping purposes, outside each sleeping area, and on each level of the dwelling unit. Retrofitted detectors may be battery operated. Multiple -purpose alarms (Carbon monoxide and smoke alarms) shall comply with all applicable standards, and requirements for listing and approval by the State (Fire Marshall. Signature: 1 � e0n, I-1 (nYn I � L Date: I A / -,� 2U 101 NOTE: Ma cero7ication is waft' used for pmjads to the extorfor of the sf ucture where access to the interior of the dwalfrrrg by the Cdy of Laguna Beach Building inspector is net achieved during the course croonsfnrchon. Field Memorandum X201 q •,zo211 -724 V 5ome5 P? Client: Ms. Linda Horioka c/o Deck & Railing Solutions Date: August 12, 2019 Project Address: 724 St James Place, City of Newport Beach Project: 19035-01 Subject: Caisson Observation for Proposed Rear Deck Addition To Existing Structure Peter Anderson of ANDERSON GEOLOGY CONSULTING, LLC. (AG) was onsite at the request of the General Contractor (Mr. David Richey, Deck & Railing Solutions) to observe and document the caisson for the proposed rear deck addition at the subject site. One (1) caisson (C-1) was drilled to a total depth of 16 -feet below existing grades in order to provide embedment into competent bedrock and undisturbed terrace deposits per the approved project plans. No groundwater or caving conditions were encountered. Conclusions: Caisson excavation for the proposed improvements summarized above have been drilled to the depths provided for the minimum embedment into competent material in accordance with the approved plans. The caissons excavations are considered acceptable from an engineering geologic viewpoint for placement of steel and concrete. All loose material and/or water should be removed from the caissons prior to placement of steel and concrete. This memorandum is not intended to verify cage length or steel reinforcement and line and grade elevations for caissons is the responsibility of others and not verified by AG representatives. As a condition for use of this field memorandum, the property owners and builder shall accept the risk of minor structural and cosmetic cracking between improvements supported by new foundation and those supported by the existing foundation. Respectfully submitted, ANDERSON GEOLOGY CONSULTING, LLC. Peter Anderson, CEG 2596 CER7IFIEG V ENGINEERING GEOLOGIST 1000 North Coast Highway Suite 10 • Laguna Beach, California 92651 • (949) 371-3690 • panderson@andersongeology.com 7 4 PI Cq_EX SD -I 4 PI C. D- 1 (E) BEAM 5D- II (E) 'LOW DECKSD- og�o I wwwz (E) BEAM F ~ (E) BEAM \ EXISTING PAD TH HORIOKA RESIDENCE 0r4;" �� '-q IS �. 724 St. James Place, Newport Beach, CA OF ' I '�� BURKE ENGINEERING REV191oN5 34167 Pacific Coast Hwy, Suite D Q FIELD REV. Dana Point, CA 92629 — ................................... PH: 949.226.7167 09/1/2018