Loading...
HomeMy WebLinkAbout2.0_Residential Design Standards Code and LCP Amendments_Presentation_Staff_PA2019-070Residential Design Standards Proposed Code Amendments Planning Commission May 7, 2020 Planning Commission - May 7, 2020 Item 2f Additional Materials Presented at Meeting Residential Design Standards Code and LCP Amendments (PA2019-070) Where We Started In May 2019, City Council initiated Code amendments and directed staff to: 1.Reduce third floor massing; 2.Reduce height and bulk of single-unit dwellings and duplexes in Multiple Unit Residential (RM) Zoning Districts; and 3.Incentivize the preservation of beach cottages. 2 of 29 Planning Commission - May 7, 2020 Item 2f Additional Materials Presented at Meeting Residential Design Standards Code and LCP Amendments (PA2019-070) 2010 Code Changes PRE-2010 ZONING CODE CURRENT ZONING CODE PROBLEM 24’ flat roof or rails 29’ sloped (midpoint @ 24’) 24’ flat roof or rails 29’ sloped (min 3:12 pitch) Only applicable to enclosed floor area Covered decks and attics excluded Floor Area Definition: •Unfinished attics excluded •Silent on required openings Certain Areas Exempt: •Balboa Island •RM Zones •25’ wide R-2 lots 29’ Sloped 1st Floor 2nd Floor 3rd Floor 29’ Sloped 1st Floor 2nd Floor 3rd Floor 24’ Midpoint x 3:12 roof pitch 15’15’ Bulk controls : •3rd floor step backs •Maximum 3rd floor area 3 of 29 Planning Commission - May 7, 2020 Item 2f Additional Materials Presented at Meeting Residential Design Standards Code and LCP Amendments (PA2019-070) Problems Easy to enclose Bulky 3rd Floor Decks No 3rd Floor Relief Not Always Applicable 4 of 29 Planning Commission - May 7, 2020 Item 2f Additional Materials Presented at Meeting Residential Design Standards Code and LCP Amendments (PA2019-070) Intent of Code Amendment Eliminate unintended consequences from 2010 ZC Update Provide more consistency in application of residential design standards 5 of 29 Planning Commission - May 7, 2020 Item 2f Additional Materials Presented at Meeting Residential Design Standards Code and LCP Amendments (PA2019-070) Not Intent of Code Amendment Comprehensive overhaul of design standards Not changing allowed heights Not prohibiting covered roof decks Not changing allowed floor area potential 6 of 29 Planning Commission - May 7, 2020 Item 2f Additional Materials Presented at Meeting Residential Design Standards Code and LCP Amendments (PA2019-070) What Has Happened 08/19/19 •1st Community Meeting •Support for changes except from RM Owners 09/10/19 •City Council Study Session •Mixed comments; regulate covered deck openings •SB 330 –Housing Crisis Act concerns 02/11/20 •Cottage Preservation Ordinance Adopted various •Consultation with community members and designers •Code refinements 03/09/20 •2nd Community Meeting •Mixed support; competing interests •Front and rear step-backs to R2 lots (25’ wide or less) 7 of 29 Planning Commission - May 7, 2020 Item 2f Additional Materials Presented at Meeting Residential Design Standards Code and LCP Amendments (PA2019-070) Proposed Code Amendments A.Revisions to 3rd Floor Standards B.Clarification of Gross Floor Area C.Applicability to Balboa Island, RM, and R-2 (25’ wide) Zones 8 of 29 Planning Commission - May 7, 2020 Item 2f Additional Materials Presented at Meeting Residential Design Standards Code and LCP Amendments (PA2019-070) 1st Floor (up to 100% of buildable) 2nd Floor (up to 100% of buildable) Range of Covered Area 3rd Floor (up to 20%) Possible 3rd Floor Location Possible 3rd Floor Location P L P L 3rd Floor (up to 20%) Side View Overhead View Current Code 15’ 15’ 15’ 15’ FSB FSB RS B RSB Third Floor Limits •15-ft stepbacks •Floor area limit (15-20% of buildable area) •No limits on non-floor area •No limits on covers 9 of 29 Planning Commission - May 7, 2020 Item 2f Additional Materials Presented at Meeting Residential Design Standards Code and LCP Amendments (PA2019-070) Covered decks not subject to 3rd floor limits Problem-Overpowering 3rd floor massingCurrent Code 10 of 29 Planning Commission - May 7, 2020 Item 2f Additional Materials Presented at Meeting Residential Design Standards Code and LCP Amendments (PA2019-070) 1st Floor (up to 100% of buildable) 2nd Floor (up to 100% of buildable)P L P L 50% Covered 3rd Floor (up to 20%) 3rd Floor (up to 20%) Side View Overhead View Proposed Change 15’ 15’ 15’ 15’ FSB FSB RS B RSB Open Open Third Floor Limits •15-ft stepbacks •Floor area limit •Covered 3rd floor deck areas subject to stepbacks •50% max coverage 11 of 29 Planning Commission - May 7, 2020 Item 2f Additional Materials Presented at Meeting Residential Design Standards Code and LCP Amendments (PA2019-070) Comparison CURRENT CODE •Only applies to enclosed floor area •Floor area limited to 15-20% PROPOSED CODE Will apply to floor area and covered deck area with a 50% maximum coverage allowance Side Elevation Side Elevation 3rd Floor Limits 12 of 29 Planning Commission - May 7, 2020 Item 2f Additional Materials Presented at Meeting Residential Design Standards Code and LCP Amendments (PA2019-070) Covered decks subject to 3rd floor limits Desired Outcome-Restrained 3rd floor massingProposed Change 13 of 29 Planning Commission - May 7, 2020 Item 2f Additional Materials Presented at Meeting Residential Design Standards Code and LCP Amendments (PA2019-070) 3rd Floor Side Stepbacks Additional 2’ from side setbacks CURRENT CODE -Only applies to enclosed floor area -Only applies to lots wider than 30’ PROPOSED CODE -Will apply to enclosed floor area and covered decks -Will apply to lots 30’ wide or greater •Majority of lots 30’ •Results in 3 levels of non-articulated walls •Results in more designs with 3rd floor articulation 1st Floor 2nd Floor 3rd Floor Front Elevation 1st Floor 2nd Floor 3rd Floor Front Elevation Side Elevation Side Elevation 2’ Stepback 14 of 29 Planning Commission - May 7, 2020 Item 2f Additional Materials Presented at Meeting Residential Design Standards Code and LCP Amendments (PA2019-070) 3rd Floor Side Stepbacks Problem–Minimal articulation of 3rd floor massing Current Code 15 of 29 Planning Commission - May 7, 2020 Item 2f Additional Materials Presented at Meeting Residential Design Standards Code and LCP Amendments (PA2019-070) 3rd Floor Side Stepbacks Desired Outcome-Increased articulation of 3rd floor massingProposed Change 16 of 29 Planning Commission - May 7, 2020 Item 2f Additional Materials Presented at Meeting Residential Design Standards Code and LCP Amendments (PA2019-070) Proposed Code Amendments A.Revisions to 3rd Floor Standards B.Clarification of Gross Floor Area C.Applicability to Balboa Island, RM, and R-2 (25’ wide) Zones 17 of 29 Planning Commission - May 7, 2020 Item 2f Additional Materials Presented at Meeting Residential Design Standards Code and LCP Amendments (PA2019-070) Comparison Openings Required for Covered Decks PRE-2010 CODE CURRENT CODE PROBLEM Two Sides Open Silent, but implemented: •One side completely open •Two sides substantially open Bulky Designs Easy to Enclose Moves required openings from front and rear of structure to sides where less visible 18 of 29 Planning Commission - May 7, 2020 Item 2f Additional Materials Presented at Meeting Residential Design Standards Code and LCP Amendments (PA2019-070) Openings Required for Covered Decks Problem-Larger appearance and bulk; unpermitted enclosures Easy to enclose Bulky designs Easy to enclose Limited openings Current Code 19 of 29 Planning Commission - May 7, 2020 Item 2f Additional Materials Presented at Meeting Residential Design Standards Code and LCP Amendments (PA2019-070) Openings Required for Covered Decks Desired Outcome-Reduced bulk; increased transparency Two sides open, except: •Minimal structural supports •Open guardrails (40%) or glass •Ground level Glass Guardrails Required open space moved to front Open Guardrails Open above Proposed Change 20 of 29 Planning Commission - May 7, 2020 Item 2f Additional Materials Presented at Meeting Residential Design Standards Code and LCP Amendments (PA2019-070) Current Code Attics Side View Overhead View 3rd Floor Deck3rdFloor Area Unfinished Attic 15’ Gross Floor Area •Attics over 6 feet in height do not count as floor area is unfinished. •Only floor area is subject to 3rd floor step backs 21 of 29 Planning Commission - May 7, 2020 Item 2f Additional Materials Presented at Meeting Residential Design Standards Code and LCP Amendments (PA2019-070) Proposed Change Attics 3rd Floor Deck 3rd Floor AreaUnfinished Attic +6’ Height Reduced Attic Heights and Bulk Gross Floor Area Any interior finished portion of a structure that is accessible and that measures more than six feet from finished floor to ceiling. 22 of 29 Planning Commission - May 7, 2020 Item 2f Additional Materials Presented at Meeting Residential Design Standards Code and LCP Amendments (PA2019-070) Proposed Code Amendments A.Revisions to 3rd Floor Standards B.Clarification of Gross Floor Area C.Applicability to Balboa Island, RM, and R-2 (25’ wide) Zones 23 of 29 Planning Commission - May 7, 2020 Item 2f Additional Materials Presented at Meeting Residential Design Standards Code and LCP Amendments (PA2019-070) 3rd Floor and Open Space Limits CURRENT CODE –Not applicable to: •Balboa Island (R-BI) Zone •Multiple Residential (RM) Zone •Two-Unit Residential (R-2) Zone lots that are 25 feet wide or less No 3rd Floor Limits No 3rd Floor Stepbacks 24 of 29 Planning Commission - May 7, 2020 Item 2f Additional Materials Presented at Meeting Residential Design Standards Code and LCP Amendments (PA2019-070) Additional Applicability Proposed third floor and open volume standards will also apply to: Balboa Island 1 or 2 unit structures in Multiple- Unit Residential (RM) Zone No changes in height Not applicable to 3+ units Front and Rear step-backs will apply to 25-foot wide or less R-2 lots Exempt from 3rd floor area, side step backs, and open volume 25 of 29 Planning Commission - May 7, 2020 Item 2f Additional Materials Presented at Meeting Residential Design Standards Code and LCP Amendments (PA2019-070) SB330 Housing Crisis Act Stimulate homebuilding to address housing shortage Expedites housing development applications Increased tenant protections and no net loss housing Suspends downzoning Suspends changes in development standards that result in less intense use 26 of 29 Planning Commission - May 7, 2020 Item 2f Additional Materials Presented at Meeting Residential Design Standards Code and LCP Amendments (PA2019-070) SB330 Housing Crisis Act Development standard can’t: Reduce density –number of potential units Reduce intensity of development -height, floor area, setbacks, lot coverage, or anything that lessens the dwelling unit potential of development. Amendment Compliance: No changes in achievable height, setbacks, floor area, density Incentivizes more density in RM zone by exempting 3+ units 3rd floor step-backs are not setbacks (design standard) Open Volume encourages modulation, does not impact floor area potential 27 of 29 Planning Commission - May 7, 2020 Item 2f Additional Materials Presented at Meeting Residential Design Standards Code and LCP Amendments (PA2019-070) Recommendations •Public hearings •Planning Commission –recommendations to City Council •City Council •Recommendations for projects under review: •Discretionary applications deemed complete (e.g., CDPs) and projects submitted for plan check prior to effective date of ordinance allowed to be reviewed under existing regulations. 28 of 29 Planning Commission - May 7, 2020 Item 2f Additional Materials Presented at Meeting Residential Design Standards Code and LCP Amendments (PA2019-070) Jaime Murillo, AICP Principal Planner 949-644-3209 jmurillo@newportbeachca.gov Questions? 29 of 29 Planning Commission - May 7, 2020 Item 2f Additional Materials Presented at Meeting Residential Design Standards Code and LCP Amendments (PA2019-070)