HomeMy WebLinkAbout005 ELEVATOR NOTES : FLOOR PLAN NOTES. DOOR SCHEDULE WINDOW SCHEDULE i- PROVIDE A FUSED DISCONNECT SWITCH FOR EACH ELEVATOR,PER NATIONAL ELECTRIC CODE,WIRE TO SUIT A A. ALL PERIMETER WALLS ARE 2 x 6 STUD FRAMED AT FIRST AND SECOND FLOORS,ALL INTERIOR SIZE THK TYPE LAZ'G. U-VAL. SHGC MFR. REMARKS SYM SIZE OPERATION GLAZ'G. MATERIAL U-VALUE SHGC MFR. REMARKS 30 AMP.SERVICE,FUSED FOR 20 AMP.DUAL ELEMENT(TIME DELAY FUSE) WITH NEUTRAL. THE FUSED WALLS ARE 2 x 4 STUD FRAMED UNLESS NOTED OTHERWISE. _ DISCONNECT SWITCH IS TO BE FURNISHED WITH NORMALLY OPEN ELECTRICAL INTERLOCK CONTACTS. THE EXTERIOR SWINGING LOW E ,�� i " " " , rr r a ELEVATOR CONTRACTOR WILL CONNECT THESE INTERLOCK CONTACTS TO THE ELEVATOR CONTROLLER. THESE ( 1 ) 2-0 x 7'-6 1 3/4 0.32 0.23 CONTINUOUS SILL �A 4-0 X 2-0 FIXED LOW E WOOD CLAD 0.32 0.23 KOLBE CONTACTS ARE REQUIRED SO THAT THE BATTERY OPERATED DESCENT UNIT CAN DIFFERENTIATE BETWEEN AN B. ALL WAILS,CEILINGS,WRAPPED BEAMS & COLUMNS IN GARAGE SHALL HAVE 5/8" TYPE 'x` SIDELtTE5 EACH SIDE ENTRY DOOR TEMPERED ACTUAL POWER FAILURE AND MANUAL USE OF THE DISCONNECT SWITCH. SUGGESTED SOURCE FOR SINGLE DRYWALL PER C.B.C.TABLE R302.6, 2 LAYERS AT GARAGE CEILING ( 18$-0" X 8'-0" - MULTI - SLIDE GLASS DOOR LOW E 0.32 0.23 4 - PANEL �,.1 TEMPERED [i] 4'-0"X 2'-0" FIXED PHASE HEAVY DUTY SAFETY SWITCHES OR EQUAL: SQUARE„D„-CAT.#H-221 - ELEC INTERLOCK#EK 300-2; I.T.E.-CAT.#SN-321 - ELEC.INTERLOCK#SC-3;-WESTINGHOUSE CAT.#HFN-221 -ELEC.INTERLOCK#EK1. C. INSULATION TO BE MAXIMUM AS WALL CAVITY ALLOWS. 2'-6" X 7'-0" 1 3/4" EXTERIOR SWINGING NONE �C 3•_0" x 4'_0" CASEMENT 2. PROVIDE A 120 VAC 20 AMP SINGLE PHASE POWER SUPPLY WITH FUSED S.P.S.T.DISCONNECT SWITCH OR D. WALL COVERINGS AT SHOWERS OR TUB W/SHOWERS TO BE CEMENT PLASTER W/ GARAGE MAN DOOR ��c,ED '4`Q�hj CIRCUIT BREAKER WITH FEEDER WIRING TO CONTROLLER FOR PER N.E.C. WATERPROOF MEMBRANE, TILE OR APPROVED EQUAL TO CLG.MATERIALS OTHER THAN �..J 2'-6"X 6'-8" 1 3/4" EXTERIOR SWINGING IN RATED JAMB ASSEMBLY 2`-6+' X 4'-0" CASEMENT STRUCTURAL ELEMENTS TO BE MOISTURE RESISTANT. PER C.B.C. SECTION 1210.3 OVERHEAD SECTIONAL 3. TEMPERATURE IN THE MACHINE ROOM TO BE MAINTAINED BETWEEN 600 AND 1000 FAHRENHEIT. RELATIVE 10'-0"X 91-0" - 2'-6" X 4'-0" CASEMENTHUMIDITY T TO EXCEED 95% SEE RECOMMENDED MACHINE ROOM PLAN. T LE THAN 1 0 4 S .IN. (,.J GARAGE DOOR ED No. C 14146 NO { J E. NET AREA OF SHOWER RECEPTOR SHALL BE NO SS 2 QI I `!'.* 11-30-19 rr r n OVERHEAD SECTIONAL OF FLOOR AREA,AND ENCOMPASS 30 INCH DIAMETER CIRCLE PER C.B.C.SECTION 6 10-0 X 9-0 - F 2'-0" X 2'-0" CASEMENT 4. PROVIDE TELEPHONE CONNECTION IN MACHINE ROOM. R307.1 AND C.P.C. 411.7 ""- GARAGE DOOR i" e ❑ FOB CA��FO 5. HOISTWAY FRAMEWORK MUST BE PLUMB AND SQUARE WITHIN 1/2"DOORS AND FRAMES TO BE INSTALLED F. ALL GLAZING LESS THAN 60"ABOVE A SHOWER OR TUB FLOOR SHALL BE MADE OF SAFETY [� 2'-$" X 7'-0" 1 3/d" INTERIOR I G CL4S ARSE MBBLYD IAMB 1„L a 3'-0" X 4'-0" FIXED PLUMB ONE ABOVE THE OTHER. ALL WALLS AND SIDE MEMBERS MUST EXTEND FRAM SILL TO BEAM. GLAZING. PER C.B.C. SECTION R308.4, ITEM 5. � ,- „ " „$ 3 0 X 7'-0 1 3 j8 POCKET SLIDING a l'-b" X 3'-0" CASEMENT 6. ADEQUATE RAIL BRACKET SUPPORT MUST BE PROVIDED AS INDICATED ON SHOP DRAWINGS FASTENINGS NOT G. CONTRACTOR TO VERIFY ATTIC ACCESS LOCATION. TO EXCEED VERTICAL INTERVALS SHOWN. 2'-4" X 71-0" 1 3/8" POCKET SLIDING El 1'-6" X T-O" CASEMENT 7. BARRICADES OUTSIDE OF ELEVATOR HOISTWAY AS REQUIRED FOR PROTECTION OF WORKMEN,OTHER H.WATER CLOSETS TO HAVE CLEARANCE OF 24"MIN. IN FRONT, 15"MIN. FROM rk TO SIDEWALLOR OBSTRUCTION (CABINET, ETC.) 10 2'-6"X,7'-O" 1 3/8" INTERIOR SWINGING K 2'-6" X 4'-O" CASEMENT CONTRACTORS OR OCCUPANTS. G t� 8. ALL WALL PATCHING, PAINTING AND GROUTING BY GENERAL CONTRACTOR, J. LANDING LENGTHS AT DOORS SHALL BE A MINIMUM OF 36 INCHES IN THE DIRECTION OF 11 2'-6" X 7'-0" 1 3/8" INTERIOR SWINGING 2'-6" X 4'-0" CASEMENT C31 TRAVEL. 9. KILN DRIED SOLID CORE WOOD OR STEEL HOISTWAY ENTRANCES SILLS AND ASSOCIATED FRAMING TO BE 3r-0"X 7r_ " 4„ INTERIOR SWINGING CLOSERZIN RATED JAMB LF N U 12 K. ALL PLUMBING FIXTURES SHALL COMPLY WITH THE MAXIMUM FLOW RATES AS NOTED IN THE 0 1 3f ELEVATOR DOOR 2-b X d-0 CASEMENT PROVIDED AND INSTALLED BY THE PURCHASER AFTER THE ELEVATOR IS SET IN PLACE,METAL SILL AT EACH. RESIDENTIAL CONSTRUCTION MINIMUM REQUIREMENTS. REFER TO R.M.R.SHEET. ASSEMBLY 2 LANDING. � (3 . 2'-4"X 7'-0" 1 3 j8" INTERIOR SWINGING H 2'-6" X 4`-0" CASEMENT � � " L. APPROVED ACOUSTICAL SEALANT SHALL BE PROVIDED ALONG THE JOINT BETWEEN THE FLOOR ® N 0) 10. FOR RESIDENTIAL APPLICATIONS CLEARANCE BETWEEN HOISTWAY DOOR AND SILL MUST NOT EXCEED 3". AND THE SEPARATION WALL. 14 2'-b"X 7'-0" 1 3/8" POCKET SLIDING El 2'-0" X 4'-O" CASEMENT a �O 11. VERIFY FINISH FLOORING IN ELEVATOR CAB. [� LOW E M. ALL PENETRATIONS INTO SOUND - RATED PARTITIONS OF FLOOR - CEILING ASSEMBLIES SHALL r rr r " Imo`' l l 9-8 X 8-0 - MULTI - SLIDE GLASS DOOR TEMPERED 0.32 0.23 4- PANEL a 2'-0"X d'-O" CASEMENT U BE SEALED WITH AN APPROVED PERMANENT RESILIENT SEALANT. G a '-0" - N. ALL RIGID CONDUIT, DUCTS, PLUMBING PIPES AND APPLIANCE VENTS LOCATED IN SOUND 4'-0" X 8 FIXED DOOR PANEL [i] 3'-0" X T-6" FIXED [A U ASSEMBLIES SHALL BE ISOLATED FROM THE BUILDING CONSTRUCTION BY MEANS OF RESILIENT SLEEVES,MOUNTS OR MINIMUM 1/4"THICK APPROVED RESILIENT MATERIAL. i 7 12'-0"X 7'-O" - MULTI - SLIDE GLASS DOOR 4- PANEL 2'-6" X 4'-0" CASEMENT e 1$ 2'-6"X 7'-0° 1 3 4" EXTERIOR SWINGING PAIR J T 2-b X 4'-Olt CASEMENT 0 PA FRENCH DOORS Job: 2'-4"X 7'-0" 1 3 8" INTERIOR SWINGING NONE N 19 / a 2'-0" X 2'-0" CASEMENT � � .� NOTE r n r e n LN 20 2-4 X 7-I 13/8 INTERIOR SWINGING 2'-0" X 2'-0" CASEMENT0 MACHINE ROOM MUST COMPLYR. NIA STOM LIT WITH ALL STATE AND LOCAL 21 2'-6"X 7'-0" 13/8" INTERIOR SWINGING 2'-6" X 4`-0" CASEMENT CODE REQUIREMENTS. " BI - PASS 13802 BEST STREET MATERIAL REQUIRED BY OTHERS: 22 $-0 x 7'-0" BEVELED MIRRORED TEMPERED FRAMELESS a 2'-6"X 4'-0" CASEMENT CaICUStOnl�ift,COnl G 1'-6"X 7'-0" 1 3/8" INTERIOR SWINGING NONE PAIR 2'-0" X 4'-0" CASEMENT GARDEN GROVE, CA 92843�-3913 •MAIN LINE DISCONNECTPq (714) 554-1300 (800) 244-9039• FAX (714) 554-1241 LIC. #417741 (See Requirements Wow) , " r rr INTERIOR SWINGING „ X " 24. 2-6 X 7-0" 1 3/8 Efl I -b 3-0 CASEMENT •CAR LIGHT DISCONNECT Z a TELEPa LIGHT, LIGHT SWITCH, AND S. 2'-4" X 7'-O" 1 3/8" POCKET SLIDING Z Al 1'-6"X T-O" CASEMENT fol CO ��Op *GFI DUPLEX RECEPTACLE 0 $ f TELEPHONE CONNECTION U 26 2'-6" X 7`-0" 1 3/8" INTERIOR SWINGING 0 B 1 2-0"X 3-0" CASEMENT " LOCKABLE ACCESS DOOR W U 0 FFKNOCK-OUT BETWEEN MACHINE #,/� 27 2'-4" X 7'-0" 1 3/8" POCKET SLIDING LU C1 2'-b" X 3'-6" CASEMENT LOW E f� PUMP NIT ROOM AND HOISTWAY � TEMPERED � (SEE DETAIL FOR SIZES) HOIST WAY(SHAFT)MUST COMPLY 28 2'-6" X 7'-0" 1 3/8" INTERIOR SWINGING D1 T-O" X 3'-6" CASEMENT LOW E WITH CONTROLLER TEMPERED t24"x24"x9" MAIN LINE 1NITI-I ALL STATE AND LOCAL D F E1 3'-0" x 3`-b" CASEMENT LOW E Nz B DISCONNECT & CAB CODE REQUIREMENTS. INTERIOR SWINGING '= 29 3'-0" X 7'-0" 1 3 f 4" CLOSER tN RATED JAMB g LIGHTING DISCONNECT ELEVATOR DOOR ASSEMBLY 1.4 :N 4 30 I%I O"X 7'-0" 1 3/8" INTERIOR SWINGING PAIR F1 2'-0"X 3'-6" CASEMENT 0 Electrical Requirements G2'-4"XT-O" 13/8" POCKET SLIDING1. 220 Sin le Ph se G1 3'-4"X 3'-6" CASEMENT a cu g a 0 LIGHT SW. & GF Panel v DUPLEX RECEPTACLE . 30 amp DiSC01C1l7JeGt 32 3'-6" X 7'-0" 1 3j8" INTERIOR SWINGING H1 3'-4"X 3'-6" CASEMENT tu CL - (4 wire/10 O) iIG (j ,W„ z , " , " rr r n r a Ix F . 3 Pole Pull Handle 33 3-0 X 7-0 1 3/8 POCKET SLIDING J 1 3-4 X 3-6 CASEMENT �r 0 -� °"41n` ` Lockable Disconnect + ++ ++ " " " I� v w 34. 2-d X 7-O 1 3/8 POCKET SLIDING K1 2-0 X 3-0 CASEMENT ® �1 w (1 Pole for Safety) Pump ago 35 00 0 3'-0" X 7'-O" 1 3/8" POCKET SLIDING L1 2'-0" X T-O" CASEMENT 13112"(#1 TANK) Shaft sizes 36 3'-0" X 7'-0" 1 3/8" POCKET SLIDING M1 2'-6" X 2'-0" AWNING L =56" XCO" r rr r " LOW E TEMPERED N1 2'-0" X 4'-0" CASEMENT 29 314"(#1 TANK) 3'8"x4'W cab S 6-0 X b-8 - SLIDING GLASS DOOR 0.32 0.23 C, t I i ._r, ..r. apgo I-N= of _361" 6" Tx4'cab 38 6'-0" X 6'-81' - SLIDING GLASS DOOR P1 2'-O" X 4'-0" CASEMENT 4'-9" RECOMENDED MINIMUM S = 40"' X 491 28"x38"cab 39 214" X 6'-8" 1 3/4" EXTERIOR SWINGING Q1 5'-0" X 4'-O" FIXED TEMPERED Drywall to drywall I`HEM ""'" 40 3'-0" X 6%8" 1 3/4" EXTERIOR SWINGING R1 LOW E F .� SHAFT (40"MIN.) a 2'-4" X 7'-0" 1 3/8" INTERIOR SWINGING NONE S1 R3 MAXIMUM 9 ., LOW E 42 3'-O"X 6'-8" 1 3/4" EXTERIOR SWINGING TEMPERED 0.32 0.23 ARCHED TOP T1 2'-6"X 3'-8" CASEMENT PLATFORM (+�'f MIN. Q U Z 5"1j" 43V d3 T-0"X 7'-0" 1 3 4'r INTERIOR SWINGING NONE CLOSER 20 MIN. �IN RATED JAMB SELF / ELEVATOR DOOR ASSEMBLY 3'-0"X 3'-6" FIXED U1 9 44 3'-0" X 7'-0" 1 3/8" INTERIOR SWINGING V 1 3'-0" X 3'-6" FIXED. ® 0 �I d � 45 2'-4"X 7'-0" 1 3/8" INTERIOR SWINGING W 1 3'-0" X 3'-6" FIXED U - __.�.,._ _,,,_, -------• xl 3r-or.X 31 _61 1 FIXED00 C? � ' W GLEAM INSIDE " � � � MOTH , c4 X� , WINDOW NOTES: DOOR NOTES: ,_ „ ,_ „ � U "�^ 1. MUNTIN PATTERNS MAY VARY FOR SIMILAR WINDOWS. REFER TO 1. MIRROR WARDROBE DOORS SHALL MEET THE IMPACT TEST Y1 3 0 X 3 6 FIXED a Z 4 ELEVATIONS FOR ACTUAL MUNTIN PATTERNS SPECIFIC FOR EACH WINDOW. REQUIREMENTS FOR SAFETY GLAZING PER C.B.C.STANDARD#54-2,PART 11. r7e !� 2. ALL BEDROOMS SHALL HAVE AT LEAST ONE DOOR OR OPERABLE WINDOW 2. GARAGE DOORS SHALL BE PROVIDED WITH GARAGE DOOR OPENERS. 2'-b" X 2'-0" CASEMENT � Pq ..^... FOR EMERGENCY ESCAPE. ESCAPE WINDOWS SHALL HAVE A MINIMUM NET R2 M� t3r CLEAR OPENABLE AREA OF 5.7 SQ.FT.WITH A MINIMUM CLEAR HEIGHT OF 24", 3. SEE TITLE-24 ENERGY CALUCATIONS FOR GLAZING AND WEATHERSTRIPING 2'-6" X 2'-0" CASEMENT © r 9S SO. FT. A MINIMUM CLEAR WIDTH OF 20"AND A MAXIMUM BOTTOM OF WINDOW SPECIFICATIONS AND REQUIREMENTS. dd} Q 12 S0. FT. {4,� >.�� OPENING HEIGHT OF 44"ABOVE THE FINISHED FLOOR. 4. ALL GLASS SHALL CONFORM TO THE RELATED PROVISIONS OF FEDERAL F 62 2'_0" X 3'_0" CASEMENT " 0 u.t p SPECIFICATION DD-G-1403 FOR TEMPERED GLASS.GLAZING SHALL CONFORM 00 I :_ LL. 3. WINDOW CONTROL OPENING DEVICE SHALL NOT REDUCE THE REQUIRED NET TO PROVISION OF THE'SAFETY STANDARD FOR ARCHITECTURAL GLAZING �+ CLEAR OPENING AREA OF THE WINDOW.R 312.2.2. MATERIAL(16CFR 1201). C2 5'-V' X 3'-6" SLIDER 0 4. SEE TITLE-24 ENERGY CALCULATIONS FOR GLAZING AND WEATHERSTRIPPING 5. ALL DOORS AND HARDWARE SHALL CONFORM TO CITY RESIDENTIAL 00 EMI LOCK SPECIFICATIONS AND REQUIREMENTS. SECURITY REGULATIONS AND ORDINANCES. D2 2'-0" X 3'-6" CASEMENT �► �" 5. ALL GLASS SHALL CONFORM TO THE RELATED PROVISIONS OF FEDERAL 6. EXTERIOR SLIDING DOORS TO BE BY XXXXXXXXX U.N.O.W/COLOR BY OWNER. RAIL FORCES sk a N �.._. "��u�� � SPECIFICATION DD-G-1403 FOR TEMPERED GLASS.GLAZING SHALL CONFORM E2 T-O" X 3'-6" CASEMENT DATE 7r�CAP'. CAP. d` TO PROVISION OF THE SAFETY STANDARD FOR ARCHITECTURAL GLAZING 7. ALL INTERIOR DOORS TO BE STAIN GRADE ALDER OR APPROVED EQUAL. 04 _ 22 - 2019 MATERIAL(16CFR 1201). WITH PAINTED JAMB AND CASING, R1 65 ' UG 105 LEIS HALL R2 220 LBS 250 �„$$ STATION b. ALL WINDOWS AND HARDWARE SHALL CONFORM TO CITY RESIDENTIAL $. ALL GLAZING IN EXTERIOR DOORS TO BE DUAL PANED,IOW-E. El 2'-6" X 3'-b" CASEMENT PxorEcr NO..y _ ,. SECURITY REGULATIONS AND ORDINANCES. 35 9. FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT LABELS. �$ - R3 3,245 LBS 3,730 LE3S`i � 36i" '1 �".,Pit, 7. ALL TEMPERED GLASS AT WINDOWS AND DOORS fi0 BE PERMANENTLY ETCH 10.DUTCH DOORS TO BE BY SMITH MILLWORKS. (949) 650-4520 G2 sx�z NO. MARKED. 8. ALL WINDOWS TO BE XXXXXXX OR EQ.,WOOD W/KYNAR FINISH, H21 N DUAL PANE LOW-E GLAZING. 9• FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT LABELS. ELEVATOR INFORMATION N.T.S.