Loading...
HomeMy WebLinkAbout20190613_Staff Report_PA2019-062CITY OF NEWPORT BEACH ZONING ADMINISTRATOR STAFF REPORT June 13, 2019 Agenda Item No. 3 SUBJECT: South Bayfront Waterpointe, LLC. Residences (PA2019-062 and PA2019-063) Coastal Development Permit Nos. CD2019-015 and CD2019-016 Tentative Parcel Map No. NP2019-004 County Tentative Parcel Map No. 2018-162 SITE LOCATION: 400 and 402 South Bay Front APPLICANT: Brandon Architects OWNER: South Bayfront Waterpointe, LLC. PLANNER: Liane Schuller, Planning Consultant 949-644-3200, lschuller@newportbeachca.gov LAND USE AND ZONING General Plan: RT (Two-Unit Residential) Zoning District: R-BI (Balboa Island) Coastal Land Use Category: RT-E (Two Unit Residential) (30.0 - 39.9 DU/AC) Coastal Zoning District: R-BI (Balboa Island) PROJECT SUMMARY A request for a tentative parcel map to divide an existing 5,180-square-foot parcel into two parcels for the purpose of constructing one single-family residence on each parcel. A request for a coastal development permit to allow the construction of a new 2,743-square- foot, single-family residence with an attached 464-square-foot, two-car garage on Parcel 1. A request for a coastal development permit to allow the construction of a new 2,659-square- foot, single-family residence with an attached 450-square-foot, two-car garage on Parcel 2. The proposed development also includes accessory elements such as walls, fences, patios, hardscape, drainage devices and landscaping. The proposed project complies with all applicable development standards and no deviations are requested. 1 South Bayfront Waterpointe, LLC. Residences (PA2019-062 and PA2019-063) Zoning Administrator, June 13, 2019 Page 2 RECOMMENDATION 1)Conduct a public hearing; 2)Find this project exempt from the California Environmental Quality Act (CEQA) pursuant to Section 15315 - Class 15 (Minor Land Divisions) and Section 15303 - Class 3 (New Construction or Conversion of Small Structures) of the State CEQA Guidelines; and 3)Adopt draft Zoning Administrator Resolution No. _ approving Coastal Development Permit No. CD2019-015 (Attachment No. ZA 1), and draft Zoning Administrator Resolution No. _ approving Tentative Parcel Map No. NP2019-004 and Coastal Development Permit No. CD2019-016 (Attachment No. ZA 2) DISCUSSION Land Use and Development Standards The subject property is located in the R-BI (Balboa Island) Coastal Zoning District, which provides for two-unit residential development and is consistent with the City’s Coastal Land Use Plan, General Plan, and Zoning Code. Coastal Development Permit CD2018-073 was reviewed and approved for the project site on February 28, 2019, allowing demolition of two existing multi-unit structures containing a total of five units. A building permit was issued for the approved demolition on April 4, 2019. A coastal development permit is required and the property is not eligible for a waiver for de minimis development because the property is located in the Coastal Commission Appeal Area. The Tentative Parcel Map is subject to a coastal development permit and conforms to Newport Beach Municipal Code (NBMC) Title 21 (Local Coastal Program Implementation Plan), including Section 21.30.035 (Coastal Subdivisions). The approval of the Tentative Parcel Map will create two approximately 2,600- square-foot parcels, reverting to the minimum lot size of the original underlying lots, and will not result in additional dwelling units beyond what the original underlying lots would allow. The new residences have been designed to provide the minimum two-car parking spaces per residence as required by Sections 20.40.040 and 21.40.040 (Off-Street Parking Spaces Required). Vehicular access will be maintained from the alley at the rear of the property. Each parcel will be served by separate utility connections. 2 South Bayfront Waterpointe, LLC. Residences (PA2019-062 and PA2019-063) Zoning Administrator, June 13, 2019 Page 3 The neighborhood is developed with a mix of one-, two- and three-story, single- family residences. The design, bulk, and scale of the proposed new development is consistent with the existing neighborhood pattern of development and expected future development consistent with applicable development standards. The proposed structures will conform to all applicable development standards, including floor area limits, setbacks, and height, as evidenced by the project plans and illustrated in Tables 1 and 2 below: Table 1 – Development Standards 400 South Bay Front (Parcel 1) Development Standard Standard Proposed Setbacks (min.) Front 0 feet 2 feet, 6 inches Side 3 feet each 3 feet each Rear 5 feet 5 feet Allowable Floor Area 3,188 square feet 3,188 square feet Allowable 3rd Floor Area 298 square feet N/A Open Volume Area 298 square feet 478 square feet Parking 2 enclosed 2 enclosed Height 24 feet flat roof 29 feet sloped roof 24 feet flat roof 29 feet sloped roof Table 2 – Development Standards 402 South Bay Front (Parcel 2) Development Standard Standard Proposed Setbacks (min.) Front 0 feet 7 feet, 6 inches Side 3 feet each 3 feet each Rear 5 feet 7 feet, 6 inches Allowable Floor Area 3,188 square feet 3,108 square feet Allowable 3rd Floor Area 299 square feet N/A Open Volume Area 299 square feet 654 square feet Parking 2 enclosed 2 enclosed Height 24 feet flat roof 29 feet sloped roof 24 feet flat roof 29 feet sloped roof Hazards The property is an oceanfront parcel that is separated from the ocean by a public boardwalk and City-owned concrete seawall/bulkhead. A Coastal Hazards and Sea Level Rise report, dated March 20, 2019, was prepared for the project by GeoSoils, 3 South Bayfront Waterpointe, LLC. Residences (PA2019-062 and PA2019-063) Zoning Administrator, June 13, 2019 Page 4 Inc. The report concludes that with the implementation of sea level rise (SLR) adaptation strategies (waterproofing of the structure and future raising of the City’s bulkhead), the proposed development will not be adversely impacted by potential coastal hazards over the next 75 years. No additional protective devices will be necessary to protect the proposed development. The finished floor elevation of the first habitable floor of the proposed structures is 9.0 feet North American Vertical Datum of 1988 (NAVD 88), which complies with the minimum 9.0 (NAVD 88) elevation standard for new structures. Pursuant to Newport Beach Municipal Code (NBMC) Section 21.30.030(C)(3)(i)(iv), the property owner will be required to enter into an agreement with the City waiving any potential right to protection to address situations in the future in which the development is threatened with damage or destruction by coastal hazards (e.g., waves, erosion, and sea level rise). The property owner will also be required to acknowledge any hazards present at the site and unconditionally waive any claim to damage or liability against the decision authority, consistent with NBMC Section 21.30.015(D)(3)(c). Both requirements are included as conditions of approval that will need to be satisfied prior to the issuance of building permits for construction. The property is located in an area known for the potential for seismic activity and liquefaction. All projects are required to comply with the California Building Code (CBC) and Building Division standards and policies. Geotechnical investigations specifically addressing liquefaction are required to be reviewed and approved prior to the issuance of a building permit. Permit issuance is also contingent on the inclusion of design mitigation identified in the investigations. Construction plans are reviewed for compliance with approved investigations and CBC prior to building permit issuance. Water Quality The development, as proposed and conditioned, incorporates design features to minimize the effect of construction and post-construction activities on the marine environment. These design features include, but are not limited to, one or more of the following: the appropriate management of equipment and construction materials, reducing runoff with permeable surfaces, and the use of post- construction best management practices to minimize the project’s adverse impact on coastal water. The project design addresses water quality during construction with a construction erosion control plan. All new construction resulting from the project will tie into an existing post-construction drainage system that includes features designed to retain dry weather and minor rain event runoff on-site. Any water not retained on-site is directed to the City’s storm drain system. 4 South Bayfront Waterpointe, LLC. Residences (PA2019-062 and PA2019-063) Zoning Administrator, June 13, 2019 Page 5 Public Access The project site is located between the nearest public road and the sea or shoreline; however, the project will not affect the public’s ability to gain access to use and/or view the coast and nearby recreational facilities. The existing residential development neither provides nor inhibits public coastal access. Implementation Plan Section 21.30A.040 (Determination of Public Access/Recreation Impacts) requires that the provision of public access bear a reasonable relationship between the requirement and the project’s impact and be proportional to the impact. In this case, the project includes two new single-family residences. Therefore, the project does not involve a change in land use, density or intensity that will result in increased demand on public access and recreation opportunities. The project is designed and sited so as not block or impede existing public access opportunities and occurs within the confines of private property. Existing coastal access conditions will not be affected by the project. Coastal access is currently provided and will continue to be provided by street ends throughout the neighborhood with access to the public boardwalk along the waterfront. The project site is not located adjacent to a coastal view road or coastal viewpoint identified by Local Coastal Program maps. The project site abuts Pearl Avenue, which provides a view corridor to the Bay; however, development will not block or impede public views. The project site may be located within the viewshed of distant public viewing areas; however, the project will replace an existing single-family residence with new single-family residences that comply with all applicable Local Coastal Program (LCP) development standards. The project will also maintain a building envelope consistent with the existing and anticipated neighborhood pattern of development. Therefore, the project does not have the potential to degrade the visual quality of the Coastal Zone or res ult in significant adverse impacts to public views. ENVIRONMENTAL REVIEW This project is exempt from the California Environmental Quality Act (CEQA) pursuant to Section 15315 under Class 15 (Minor Land Divisions) and Section 15303 – Class 3 (New Construction or Conversion of Small Structures) of the CEQA Guidelines, California Code of Regulations, Title 14, Chapter 3, because it has no potential to have a significant effect on the environment. The Class 15 exemption allows the division of property in urbanized areas zoned for residential, commercial, or industrial use into four or fewer parcels when the division is in conformance with the General Plan and Zoning, no variances or exceptions are requi red, all services and access to the proposed parcels are available, the parcel was not involved in a division of a larger parcel within the previous two years, and the parcel does not have 5 South Bayfront Waterpointe, LLC. Residences (PA2019-062 and PA2019-063) Zoning Administrator, June 13, 2019 Page 6 an average slope greater than 20 percent. The Class 3 exemption includes the construction and location of limited numbers of new, small facilities or structures. The proposed parcels are consistent with the land use and zoning designations, do not have a slope greater than 20 percent, and were not involved in the division of a larger parcel within two years. One single-family residence and attached garage is proposed on each parcel. PUBLIC NOTICE Notice of this public hearing was published in the Daily Pilot, mailed to all owners and residential occupants of property within 300 feet of the boundaries of the site (excluding intervening rights-of-way and waterways), including the applicant, and posted on the subject property at least 10 days before the scheduled hearing, consistent with the provisions of the Municipal Code. Additionally, the item appeared on the agenda for this meeting, which was posted at City Hall and on the City website. APPEAL PERIOD: This action shall become final and effective 14 days following the date the Resolution is adopted unless within such time an appeal or call for review is filed with the Community Development Director in accordance with the provisions of Title (Subdivisions) and Title 21 (Local Coastal Program Implementation Plan) of the Newport Beach Municipal Code. Final action taken by the City may be appealed to the Coastal Commission in compliance with Section 21.64.035 of the City’s certified LCP and Title 14 California Code of Regulations, Sections 13111 through 13120, and Section 30603 of the Coastal Act. For additional information on filing an appeal, contact the Planning Division at 949-644-3200. Prepared by: RU/ls Attachments: ZA 1 Draft Resolution (PA2019-062) ZA 2 Draft Resolution (PA2019-063) ZA 3 Vicinity Map ZA 4 Tentative Parcel Map No. NP2019-004 County Tentative Map No. 2018-162 ZA 5 Project Plans 6 Attachment No. ZA 1 Draft Resolution for PA2019-062 7 RESOLUTION NO. ZA2019-### A RESOLUTION OF THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH, CALIFORNIA APPROVING TENTATIVE PARCEL MAP NO. NP2019-004 AND COASTAL DEVELOPMENT PERMIT NO. CD2019-016, CREATING TWO PARCELS AND ALLOWING CONSTRUCTION OF A NEW SINGLE-FAMILY RESIDENCE ON PARCEL 1 AT 400 SOUTH BAY FRONT (PA2019-063) THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH HEREBY FINDS AS FOLLOWS: SECTION 1. STATEMENT OF FACTS. 1. An application was filed by Brandon Architects (“Applicant”), on behalf of South Bayfront Waterpointe, LLC (“Owner”), with respect to property located at 400 South Bay Front, and legally described as Lot 1 in Block 7 of Section 1, Balboa Island, requesting approval of a tentative parcel map and a coastal development permit. 2. The Applicant proposes to subdivide an existing 5,180-square-foot parcel into two parcels and to construct a new 2,743-square-foot, single-family residence with an attached 464- square-foot, two-car garage on Parcel 1. 3. The subject property is located within the R-BI (Balboa Island) Zoning District and the General Plan Land Use Element category is RT (Two-Unit Residential). 4. The subject property is located within the coastal zone and has a Coastal Land Use Designation of Two-Unit Residential (RT-E) (30.0 - 39.9 DU/AC) and a Coastal Zoning District of Balboa Island (R-BI). 5. A public hearing was held on June 13, 2019, in the Corona del Mar Conference Room (Bay E-1st Floor) at 100 Civic Center Drive, Newport Beach. A notice of time, place and purpose of the meeting was given in accordance with the NBMC. Evidence, both written and oral, was presented to, and considered by, the Zoning Administrator at this meeting. SECTION 2. CALIFORNIA ENVIRONMENTAL QUALITY ACT DETERMINATION. 1. This project has been determined to be categorically exempt pursuant to the State CEQA (California Environmental Quality Act) Guidelines under Class 15 (Minor Land Divisions) and under Class 3 (New Construction or Conversion of Small Structures). 2. The Class 15 exemption allows the division of property in urbanized areas zoned for residential, commercial, or industrial use into four or fewer parcels when the division is in conformance with the General Plan and Zoning, no variances or exceptions are required, all services and access to the proposed parcels are available, the parcel was not involved in a division of a larger parcel within the previous two years, and the parcel does not have an average slope greater than 20 percent. The proposed parcels are 8 Zoning Administrator Resolution No. ZA2019-### Page 2 of 12 consistent with the land use and zoning designations, do not have a slop e greater than 20 percent, and were not involved in the division of a larger parcel within two years. Therefore, the proposed parcel map is eligible for the Class 15 exemption. 3. The Class 3 exemption allows the construction and location of limited numbers of new, small facilities or structures including one single-family residence in a residential zone. SECTION 3. REQUIRED FINDINGS. In accordance with Section 21.52.015 (Coastal Development Permits) of the Newport Beach Municipal Code, the following findings and facts in support of such findings are set forth: Finding: A. Conforms to all applicable sections of the certified Local Coastal Program. Facts in Support of Finding: 1. The Tentative Parcel Map and Coastal Development Permit is for a property within a developed neighborhood, on a lot that is not near any natural landforms including coastal bluffs, and is not within the proximity of any environmentally sensitive areas. 2. The proposed structure conforms to all applicable development standards including, but not limited to, floor area limitation, setbacks, height, and parking: a. The maximum floor area limitation is 3,188 square feet and the proposed gross floor area is 3,188 square feet. b. The proposed development will provide the required setbacks, which are zero feet along the front property line abutting the boardwalk, three feet along the side property lines, and five feet along the rear property line abutting the alley. c. The highest flat roof is no more than 24 feet, measured from the finished floor level of 9.00 feet North American Vertical Datum of 1988 (NAVD 88) and the highest roof ridge is no more than 29 feet, measured from the finished floor level, which complies with the maximum height limitation. d. The project includes enclosed garage parking for two vehicles, which complies with the minimum two-space parking requirement for single-family residences with less than 4,000 square feet of livable floor area. 3. The proposed design, bulk, and scale of the development is consistent with the existing neighborhood pattern of development and expected future development consistent with applicable development standards as the neighborhood is predominantly developed with two-story, single-family residences. 9 Zoning Administrator Resolution No. ZA2019-### Page 3 of 12 4. The property is an oceanfront lot that is separated from the ocean by a public boardwalk and City-owned concrete seawall/bulkhead. A Coastal Hazards and Sea Level Rise report, dated March 20, 2019, was prepared for the project by GeoSoils, Inc. The report concludes that, with the implementation of sea level rise (SLR) adaptation strategies (waterproofing of the structure and future raising of the City’s bulkhead), the proposed development will not be adversely impacted by potential coastal hazards over the next 75 years. No additional protective devices will be necessary to protect the proposed development. 5. Pursuant to Newport Beach Municipal Code (NBMC) Section 21.30.030(C)(3)(i)(iv), the property owner will be required to enter into an agreement with the City waiving any potential right to protection to address situations in the future in which the development is threatened with damage or destruction by coastal hazards (e.g., waves, erosion, and sea level rise). The property owner will also be required to acknowledge any hazards present at the site and unconditionally waive any claim to damage or liability against the decision authority, consistent with NBMC Section 21.30.015(D)(3)(c). Both requirements are included as conditions of approval that will need to be satisfied prior to the issuance of building permits for construction. 6. The finished floor elevation of the first floor of the proposed structure is 9.00 feet (NAVD 88), which complies with the minimum 9.0-foot (NAVD 88) elevation standard for new structures. 7. The property is located in an area known for the potential of seismic activity and liquefaction. All projects are required to comply with the California Building Code (CBC) and Building Division standards and policies. Geotechnical investigations specifically addressing liquefaction are required to be reviewed and approved prior to the issuance of building permits. Permit issuance is also contingent on the inclusion of design mitigation identified in the investigations. Construction plans are reviewed for compliance with approved investigations and the CBC prior to building permit issuance. 8. A post-construction drainage system will be installed that includes drainage and percolation features designed to retain dry weather and minor rain runoff on-site to ensure the project does not impact water quality. Any water not retained on-site is directed to the City’s storm drain system. 9. The project design addresses water quality with a construction erosion control plan that outlines temporary Best Management Practices (BMPs) to be implemented during construction to minimize erosion and sedimentation, and to minimize pollution of runoff derived by construction chemicals and materials. No water quality impacts to coastal waters are anticipated based upon the location and elevation of the property. 10. New landscaping will be verified for compliance with NBMC Section 21.30.075 (Landscaping). A condition of approval is included that requires drought-tolerant, and prohibits invasive species. Prior to issuance of the building permits, the final landscape plans will be reviewed to verify invasive species are not planted. 10 Zoning Administrator Resolution No. ZA2019-### Page 4 of 12 11. The property is not located near coastal view roads and is not located near any identified public viewpoints; therefore, the project will not negatively impact public coastal views. Finding: B. Conforms with the public access and public recreation policies of Chapter 3 of the Coastal Act if the project is between the nearest public road and the sea or shoreline of any body of water located within the coastal zone. Fact in Support of Finding: 1. The project site is located between the nearest public road and the sea or shoreline; however, the project will not affect the public’s ability to gain access to use and/or view the coast and nearby recreational facilities. The proposed residential development neither provides nor inhibits public coastal access. Implementation Plan Section 21.30A.040 (Determination of Public Access/Recreation Impacts) requires that the provision of public access bear a reasonable relationship between the requirement and the project’s impact and be proportional to the impact. In this case, the project includes the construction of a new two-story, single-family residence. The project does not involve a change in land use, density or intensity that will result in increased demand on public access and recreation opportunities. 2. The project is designed and sited so as not to block or impede existing public access opportunities and occurs within the confines of private property. Existing coastal access conditions will not be affected by the proposed development. Coastal access is currently provided and will continue to be provided by street ends throughout the neighborhood with access to the public boardwalk along the waterfront. The Zoning Administrator determined in this case that the Tentative Parcel Map is consistent with the legislative intent of NBMC Title 20 (Planning and Zoning) and is approved based on the following findings per NBMC Section 19.12.070 (Required Findings for Action on Tentative Maps): Finding: C. That the proposed map and the design or improvements of the subdivision are consistent with the General Plan and any applicable specific plan, and with applicable provisions of the Subdivision Map Act and this Subdivision Code. Facts in Support of Finding: 1. The Tentative Parcel Map is for the creation of two separate parcels, with one single - family residence to be constructed on each parcel. The proposed subdivision and improvements are consistent with the density of the R-BI Zoning District (Balboa Island) and current General Plan Land Use Designation (Two-Unit Residential). 2. The subject property is not located within a specific plan area. 11 Zoning Administrator Resolution No. ZA2019-### Page 5 of 12 3. The project is conditioned to require public improvements, including the reconstruction of drains, sidewalks, curbs, and gutters along the South Bay Front alleyway, consistent with the requirements of NBMC Title 19. Finding: D. That the site is physically suitable for the type and density of development. Facts in Support of Finding: 1. The lot is physically suitable for the proposed single-unit development. The lot is rectangular in shape, 30.5 feet wide, 86.3 feet deep, and approximately 2,600 square feet in area. 2. The project site will maintain vehicular access from the alley at the rear of the property and existing utility services are adequate for the proposed single-unit development. Finding: E. That the design of the subdivision or the proposed improvements are not likely to cause substantial environmental damage nor substantially and avoidably injure fish or wildlife or their habitat. However, notwithstanding the foregoing, the decision making body may nevertheless approve such a subdivision if an environmental impact report was prepared for the project and a finding was made pursuant to Section 21081 of the California Environmental Quality Act that specific economic, social, or other considerations make infeasible the mitigation measures or project alternatives identified in the environmental impact report. Facts in Support of Finding: 1. The site was previously developed with a multiple-unit residence. 2. The property is located in an urbanized area that does not contain any sensitive vegetation or habitat. 3. The project is categorically exempt under Section 15315 (Article 19 of Chapter 3), of the California Environmental Quality Act (CEQA) Guidelines – Class 15 (Minor Land Alterations) for the reasons noted in Section 2 of this Resolution. Finding: F. That the design of the subdivision or the type of improvements is not likely to cause serious public health problems. 12 Zoning Administrator Resolution No. ZA2019-### Page 6 of 12 Facts in Support of Finding: 1. Approval of the Tentative Parcel Map will create two approximately 2,600 -square-foot parcels, reverting to the minimum lot size of the original underlying lots, and will not result in additional dwelling units beyond what the original underlying lots would allow 2. All improvements associated with the project will comply with all Building, Public Works, and Fire Codes, which are in place to prevent serious public health problems. Public improvements will be required of the developer per NBMC Section 19.28.010 (General Improvement Requirements) and Section 66411 (Local Agencies to Regulate and Control Design of Subdivisions) of the Subdivision Map Act. All ordinances of the City and all Conditions of Approval will be complied with. Finding: G. That the design of the subdivision or the type of improvements will not conflict with easements, acquired by the public at large, for access through or use of property within the proposed subdivision. In this connection, the decision making body may approve a map if it finds that alternate easements, for access or for use, will be provided and that these easements will be substantially equivalent to ones previously acquired by the public. This finding shall apply only to easements of record or to easements established by judgment of a court of competent jurisdiction and no authority is hereby granted to the City Council to determine that the public at large has acquired easements for access through or use of property within a subdivision. Fact in Support of Finding: 1. The Public Works Department has reviewed the proposed parcel map and determined that the design of the development will not conflict with easements acquired by the public at large, for access through, or use of property within the proposed development, because there are no public easements located on the property. Finding: H. That, subject to the detailed provisions of Section 66474.4 of the Subdivision Map Act, if the land is subject to a contract entered into pursuant to the California Land Conservation Act of 1965 (Williamson Act), the resulting parcels following a subdivision of the land would not be too small to sustain their agricultural use or the subdivision will result in residential development incidental to the commercial agricultural use of the land. Facts in Support of Finding: 1. The property is not subject to the Williamson Act because the subject property is not designated as an agricultural preserve and is less than 100 acres in area. 2. The site is developed for residential use and is located in the Two-Unit Residential (R- 2) Zoning District, which permits residential uses. 13 Zoning Administrator Resolution No. ZA2019-### Page 7 of 12 Finding: I. That, in the case of a “land project” as defined in Section 11000.5 of the California Business and Professions Code: (1) there is an adopted specific plan for the area to be included within the land project; and (2) the decision making body finds that the proposed land project is consistent with the specific plan for the area. Facts in Support of Finding: 1. California Business and Professions Code Section 11000.5 has been repealed by the Legislature. However, this project site is not considered a “land project” as previously defined in Section 11000.5 of the California Business and Professions Code because the project site does not contain 50 or more parcels of land. 2. The project is not located within a specific plan area. Finding: J. That solar access and passive heating and cooling design requirements have been satisfied in accordance with Sections 66473.1 and 66475.3 of the Subdivision Map Act. Fact in Support of Finding: 1. The Tentative Parcel Map and any future improvements are subject to Title 24 of the California Code of Regulations that requires new construction to meet minimum heating and cooling efficiency standards depending on location and climate. The Newport Beach Building Division enforces Title 24 compliance through the plan check and inspection process. Finding: K. That the subdivision is consistent with Section 66412.3 of the Subdivision Map Act and Section 65584 of the California Government Code regarding the City’s share of the regional housing need and that it balances the housing needs of the reg ion against the public service needs of the City’s residents and available fiscal and environmental resources. Fact in Support of Finding: 1. The proposed single-family residence is consistent with the R-2 Zoning District, which allows a maximum of two residential units on the property. The Tentative Parcel Map to create two parcels for the purpose of constructing a single-family residence on each parcel will not affect the City in meeting its regional housing need. 14 Zoning Administrator Resolution No. ZA2019-### Page 8 of 12 Finding: L. That the discharge of waste from the proposed subdivision into the existing sewer system will not result in a violation of existing requirements prescribed by the Regional Water Quality Control Board. Fact in Support of Finding: 1. The new single-family residence is designed so that wastewater discharge into the existing sewer system complies with the Regional Water Quality Control Board (RWQCB) requirements. Finding: M. For subdivisions lying partly or wholly within the Coastal Zone, that the subdivision conforms with the certified Local Coastal Program and, where applicable, with public access and recreation policies of Chapter Three of the Coastal Act. Fact in Support of Finding: 1. The subject property is within the Coastal Zone. The facts in support of findings A and B above are hereby incorporated by reference. SECTION 4. DECISION. NOW, THEREFORE, BE IT RESOLVED: 1. The Zoning Administrator of the City of Newport Beach hereby approves Tentative Parcel Map No. NP2019-004 and Coastal Development Permit No. CD2018-016, subject to the conditions set forth in Exhibit “A,” which is attached hereto and incorporated by reference. 2. This action shall become final and effective 14 days following the date this Resolution was adopted unless within such time an appeal or call for review is filed with the Director of Community Development in accordance with the provisions of NBMC Title 19 (Subdivisions) and Title 21 (Local Coastal Program Implementation Plan). PASSED, APPROVED, AND ADOPTED THIS 13th DAY OF JUNE, 2019. _____________________________________ Rosalinh Ung, Zoning Administrator 15 Zoning Administrator Resolution No. ZA2019-### Page 9 of 12 EXHIBIT “A” CONDITIONS OF APPROVAL Planning Division 1. The development shall be in substantial conformance with the approved site plan, floor plans and building elevations stamped and dated with the date of this approval (except as modified by applicable conditions of approval). 2. Revisions to the approved plans may require an amendment to this Coastal Development Permit or the processing of a new coastal development permit. 3. Tentative Parcel Map No. NP2019-004 and Coastal Development Permit No. CD2019- 016 shall expire unless exercised within 24 months from the date of approval as specified in Section 21.54.060 (Time Limits and Extensions) of the Newport Beach Municipal Code, unless an extension is otherwise granted. 4. Prior to final building permit inspection, an agreement in a form approved by the City Attorney between the property owner and the City shall be executed and recorded waiving rights to the construction of future shoreline protection devices to address the threat of damage or destruction from waves, erosion, storm conditions, landslides, seismic activity, bluff retreat, sea level rise, or other natural hazards that may affect the property, or development of the property, today or in the future. The agreement shall be binding against the property owners and successors and assigns. 5. Prior to the issuance of a building permit, the property owner shall sign a notarized signed letter acknowledging all hazards present at the site, assuming the risk of injury or damage from such hazards, unconditionally waiving any claims of damage against the City from such hazards, and to indemnify and hold harmless City, its City Cou ncil, its boards and commissions, officials, officers, employees and agents from and against any and all claims, demands, obligations, damages, actions, causes of action, suits, losses, judgements, fines, penalties, liabilities, costs and expenses (including without limitation, attorney’s fees, disbursements and court costs) of every kind and nature whatsoever which may arise from or in any manner relate (directly or indirectly) to City’s approval of development. The letter shall be scanned into the plan se t prior to building permit issuance. 6. Prior to the issuance of a building permit, a copy of the Resolution, including conditions of approval Exhibit “A,” shall be incorporated into the Building Division and field sets of plans. 7. The project is subject to all applicable City ordinances, policies, and standards, unless specifically waived or modified by the conditions of approval. 16 Zoning Administrator Resolution No. ZA2019-### Page 10 of 12 8. The applicant shall comply with all federal, state, and local laws. Material violation of any of those laws in connection with the use may be cause for revocation of this Coastal Development Permit and Tentative Parcel Map. 9. This Coastal Development Permit and Tentative Parcel Map may be modified or revoked by the Zoning Administrator if determined should they determine that the proposed uses or conditions under which it is being operated or maintained is detrimental to the public health, welfare or materially injurious to property or improvements in the vicinity or if the property is operated or maintained so as to constitute a public nuisance. 10. Should the property be sold or otherwise come under different ownership, any future owners or assignees shall be notified of the conditions of this approval by either the current business owner, property owner or the leasing agent. 11. No demolition or construction materials, equipment debris or waste shall be placed or stored in a location that would enter sensitive habitat, receiving waters, or a storm drain, or result in impacts to environmentally sensitive habitat areas, streams, wetland or their buffers. 12. Trash and debris shall be disposed in proper trash and recycling receptacles at the end of each construction day. Solid waste, including excess concrete, shall be disposed in adequate disposal facilities at a legal disposal site or recycled at a recycling facility. Prior to issuance of a building permit, the applicant shall submit a final construction erosion control plan. The plan shall be subject to review and approval by the Building Division. 13. Prior to issuance of a building permit, the applicant shall submit a final construction erosion control plan. The plan shall be subject to review and approval by the Building Division. 14. All landscape materials and irrigation systems shall be maintained in accordance with the approved landscape plan. All landscaped areas shall be maintained in a healthy and growing condition and shall receive regular pruning, fertilizing, mowing, and trimming. All landscaped areas shall be kept free of weeds and debris. All irrigation systems shall be kept operable, including adjustments, replacements, repairs, and cleaning as part of regular maintenance. 15. Prior to issuance of a building permit, the applicant shall pay any unpaid administrative costs associated with the processing of this application to the Planning Division. 16. The discharge of any hazardous materials into storm sewer systems or receiving waters shall be prohibited. Machinery and equipment shall be maintained and washed in confined areas specifically designed to control runoff. A designated fueling and vehicle maintenance area with appropriate berms and protection to prevent spillage shall be provided as far a Debris from demolition shall be removed from work areas each day and removed from the project site within 24 hours of the completion of the project. Stockpiles and construction materials shall be covered, enclosed on all sites, not stored in contact with the soil, and located as far away as possible from drain inlets and any waterway from storm drain systems or receiving waters as possible. 17 Zoning Administrator Resolution No. ZA2019-### Page 11 of 12 17. To the fullest extent permitted by law, applicant shall indemnify, defend and hold harmless City, its City Council, its boards and commissions, officials, officers, employees, and agents from and against any and all claims, demands, obligations, damages, actions, causes of action, suits, losses, judgments, fines, penalties, liabilities, costs and expenses (including without limitation, attorney’s fees, disbursements and court costs) of every kind and nature whatsoever which may arise from or in any manner relate (directly or indirectly) to City’s approval of the South Bayfront Waterpointe, LLC. Residences including, but not limited to, Tentative Parcel Map No. NP2019-004 and Coastal Development Permit No. CD2019-016 (PA2019-063). This indemnification shall include, but not be limited to, damages awarded against the City, if any, costs of suit, attorneys' fees, and other expenses incurred in connection with such claim, action, causes of action, suit or proceeding whether incurred by applicant, City, and/or the parties initiating or bringing such proceeding. The applicant shall indemnify the City for all of City's costs, attorneys' fees, and damages which City incurs in enforcing the indemnification provisions set forth in this condition. The applicant shall pay to the City upon demand any amount owed to the City pursuant to the indemnification requirements prescribed in this condition. Public Works Department 18. A parcel map shall be recorded. The map shall be prepared on the California coordinate system (North American Datum of 1983). Prior to recordation of the Map, the surveyor/engineer preparing the Map shall submit to the County Surveyor and the City of Newport Beach a digital-graphic file of said map in a manner described in Section 7 - 9-330 and 7-9-337 of the Orange County Subdivision Code and Orange County Subdivision Manual, Subarticle 18. The Map to be submitted to the City of Newport Beach shall comply with the City's CADD Standards. Scanned images will not be accepted. 19. Prior to recordation of the parcel map, the surveyor/engineer preparing the map shall tie the boundary of the map into the Horizontal Control System established by the County Surveyor in a manner described in Section 7-9-330 and 7-9-337 of the Orange County Subdivision Code and Orange County Subdivision Manual, Subarticle 18. Monuments (one inch iron pipe with tag) shall be set on each lot corner unless otherwise approved by the Subdivision Engineer. Monuments shall be protected in place if installed prior to completion of construction project. 20. All improvements shall be constructed as required by Ordinance and the Public Works Department. 21. An encroachment permit is required for all work activities within the public right-of-way. 22. Reconstruct any existing broken and/or otherwise damaged concrete curb and sidewalk panels along the Pearl Avenue frontage and any existing broken and/or otherwise damaged concrete alley panels. 23. All existing overhead utilities shall be undergrounded. 18 Zoning Administrator Resolution No. ZA2019-### Page 12 of 12 24. The rear alley setback shall remain clear of any above ground improvements or obstructions. 25. All existing private, non-standard improvements within the Pearl Avenue right-of-way and/or extensions of private, non-standard improvements into the Pearl Avenue right- of-way fronting the development shall be removed. 26. Any proposed private, non-standard improvements within the South Bay Front right -of- way shall comply with City Council Policy L-6. 27. Existing street trees within the Pearl Avenue right -of-way shall be protected-in-place. Removal of said trees will require approval from the Parks and Trees Division of the Public Works Department. 28. Each parcel shall be served by its individual water meter and sewer lateral and cleanout. Each water meter and sewer cleanout shall be installed with a traffic-grade box and cover. 29. All improvements shall comply with the City's sight distance requirement. See City Standard 110-L. 30. In case of damage done to public improvements surrounding the development site by the private construction, additional reconstruction within the public right -of-way could be required at the discretion of the Public Works Inspector. 19 Attachment No. ZA 2 Draft Resolution for PA2019-063 20 RESOLUTION NO. ZA2019-### A RESOLUTION OF THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH APPROVING COASTAL DEVELOPMENT PERMIT NO. CD2019-015 TO CONSTRUCT A NEW SINGLE-FAMILY RESIDENCE AT 402 SOUTH BAY FRONT (PA2019-062) THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH HEREBY FINDS AS FOLLOWS: SECTION 1. STATEMENT OF FACTS. 1. An application was filed by Brandon Architects (“Applicant”), on behalf of South Bayfront Waterpointe, LLC (“Owner”), with respect to property located at 402 South Bay Front, and legally described as Lot 2 in Block 7 of Section 1, Balboa Island, requesting approval of a coastal development permit. 2. The Applicant proposes to construct a new 2,659-square-foot, single-family residence with an attached 450-square-foot, two-car garage. 3. The subject property is located within the R-BI (Balboa Island) Zoning District and the General Plan Land Use Element category is RT (Two-Unit Residential). 4. The subject property is located within the coastal zone and has a Coastal Land Use Designation of Two-Unit Residential (RT-E) (30.0 - 39.9 DU/AC) and a Coastal Zoning District of Balboa Island (R-BI). 5. A public hearing was held on June 13, 2019, in the Corona del Mar Conference Room (Bay E-1st Floor) at 100 Civic Center Drive, Newport Beach. A notice of time, place and purpose of the meeting was given in accordance with the NBMC. Evidence, both written and oral, was presented to, and considered by, the Zoning Administrator at this meeting. SECTION 2. CALIFORNIA ENVIRONMENTAL QUALITY ACT DETERMINATION. 1. This project is categorically exempt from the California Environmental Quality Act (CEQA) pursuant to Section 15301 under Class 3 (New Construction or Conversion of Small Structures) of the CEQA Guidelines. 2. Class 3 includes the construction of a single-family residence in a residential zone. The proposed project includes the construction of a new 2,659-square-foot, single-family residence with an attached 450-square-foot, two-car garage. 21 Zoning Administrator Resolution No. ZA2019-### Page 2 of 7 SECTION 3. REQUIRED FINDINGS. In accordance with Section 21.52.015 (Coastal Development Permits) of the Newport Beach Municipal Code, the following findings and facts in support of such findings are set forth: Finding: A. Conforms to all applicable sections of the certified Local Coastal Program. Facts in Support of Finding: 1. The proposed structure conforms to all applicable development standards including, but not limited to, floor area limitation, setbacks, height, and parking : a. The maximum floor area limitation is 3,188 square feet and the proposed gross floor area is 3,108 square feet. b. The proposed development will provide the required setbacks, which are zero feet along the front property line abutting the boardwalk, three feet along the side property lines, and five feet along the rear property line abutting the alley. c. The highest flat roof is no more than 24 feet, measured from the finished floor level of 9.00 feet North American Vertical Datum of 1988 (NAVD 88) and the highest roof ridge is no more than 29 feet, measured from the finished floor level, which complies with the maximum height limitation. d. The project includes enclosed garage parking for two vehicles, which complies with the minimum two-space parking requirement for single-family residences with less than 4,000 square feet of livable floor area. 2. The proposed design, bulk, and scale of the development is consistent with the existing neighborhood pattern of development and expected future development consiste nt with applicable development standards as the neighborhood is predominantly developed with two-story, single-family residences. 3. The property is an oceanfront lot that is separated from the ocean by a public boardwalk and City-owned concrete seawall/bulkhead. A Coastal Hazards and Sea Level Rise report, dated March 20, 2019, was prepared for the project by GeoSoils, Inc. The report concludes that, with the implementation of sea level rise (SLR) adaptation strategies (waterproofing of the structure and future raising of the City’s bulkhead), the proposed development will not be adversely impacted by potential coastal hazards over the next 75 years. No additional protective devices will be necessary to protect the proposed development. 4. Pursuant to Newport Beach Municipal Code (NBMC) Section 21.30.030(C)(3)(i)(iv), the property owner will be required to enter into an agreement with the City waiving any potential right to protection to address situations in the future in which the development is 22 Zoning Administrator Resolution No. ZA2019-### Page 3 of 7 threatened with damage or destruction by coastal hazards (e.g., waves, erosion, and sea level rise). The property owner will also be required to acknowledge any hazards present at the site and unconditionally waive any claim to damage or liability against the decision authority, consistent with NBMC Section 21.30.015(D)(3)(c). Both requirements are included as conditions of approval that will need to be satisfied prior to the issuance of building permits for construction. 5. The finished floor elevation of the first floor of the proposed structure is 9.00 feet (NAVD 88), which complies with the minimum 9.0-foot (NAVD 88) elevation standard for new structures. 6. The property is located in an area known for the potential of seismic activity and liquefaction. All projects are required to comply with the California Building Code (CBC) and Building Division standards and policies. Geotechnical investigations specifically addressing liquefaction are required to be reviewed and approved prior to the issuance of building permits. Permit issuance is also contingent on the inclusion of design mitigation identified in the investigations. Construction plans are reviewed for compliance with approved investigations and the CBC prior to building permit issuance. 7. A post-construction drainage system will be installed that includes drainage and percolation features designed to retain dry weather and minor rain runoff on-site to ensure the project does not impact water quality. Any water not retained on-site is directed to the City’s storm drain system. 8. The project design addresses water quality with a construction erosion control plan that outlines temporary Best Management Practices (BMPs) to be implemented during construction to minimize erosion and sedimentation, and to minimize pollution of runoff derived by construction chemicals and materials. No water quality impacts to coastal waters are anticipated based upon the location and elevation of the property. 9. New landscaping will be verified for compliance with NBMC Section 21.30.075 (Landscaping). A condition of approval is included that requires drought-tolerant, and prohibits invasive species. Prior to issuance of the building permits, the final landscape plans will be reviewed to verify invasive species are not planted. 10. The property is not located near coastal view roads and is not located near any identified public viewpoints; therefore, the project will not negatively impact public coastal views. Finding: B. Conforms with the public access and public recreation policies of Chapter 3 of the Coastal Act if the project is located between the nearest public road and the sea or shoreline of any body of water located within the coastal zone. 23 Zoning Administrator Resolution No. ZA2019-### Page 4 of 7 Facts in Support of Finding: 1. The project site is located between the nearest public road and the sea or shoreline; however, the project will not affect the public’s ability to gain access to use and/or view the coast and nearby recreational facilities. The proposed residential development neither provides nor inhibits public coastal access. Implementation Plan Section 21.30A.040 (Determination of Public Access/Recreation Impacts) requires that the provision of public access bear a reasonable relationship between the requirement and the project’s impact and be proportional to the impact. In this case, the project includes the construction of a new two-story, single-family residence. The project does not involve a change in land use, density or intensity that will result in increased demand on public access and recreation opportunities. 2. The project is designed and sited so as not to block or impede existing public access opportunities and occurs within the confines of private property. Existing coastal access conditions will not be affected by the proposed development. Coastal access is currently provided and will continue to be provided by street ends throughout the neighborhood with access to the public boardwalk along the waterfront. SECTION 4. DECISION. NOW, THEREFORE, BE IT RESOLVED: 1. The Zoning Administrator of the City of Newport Beach hereby approves Coastal Development Permit No. CD2019-015, subject to the conditions set forth in Exhibit “A,” which is attached hereto and incorporated by reference. 2. This action shall become final and effective 14 days following the date this Resolution was adopted unless within such time an appeal or call for review is filed with the Community Development Director in accordance with the provisions of Title 21 Local Coastal Implementation Plan, of the Newport Beach Municipal Code. Final action taken by the City may be appealed to the Coastal Commission in compliance with Section 21.64.035 of the City’s certified LCP and Title 14 California Code of Regulations, Sections 13111 through 13120, and Section 30603 of the Coastal Act. PASSED, APPROVED, AND ADOPTED THIS 13th DAY OF JUNE, 2019. _____________________________________ Rosalinh Ung, Zoning Administrator 24 Zoning Administrator Resolution No. ZA2019-### Page 5 of 7 EXHIBIT “A” CONDITIONS OF APPROVAL 1. The development shall be in substantial conformance with the approved site plan, floor plans and building elevations stamped and dated with the date of this approval (except as modified by applicable conditions of approval). 2. Revisions to the approved plans may require an amendment to this Coastal Development Permit or the processing of a new coastal development permit. 3. Coastal Development Permit No. CD2019-015 shall expire unless exercised within 24 months from the date of approval as specified in Section 21.54.060 (Time Limits and Extensions) of the Newport Beach Municipal Code, unless an extension is otherwise granted. 4. A parcel map shall be recorded. The map shall be prepared on the California coordinate system (North American Datum of 1983). Prior to recordation of the Map, the surveyor/engineer preparing the Map shall submit to the County Surveyor and the City of Newport Beach a digital-graphic file of said map in a manner described in Section 7 - 9-330 and 7-9-337 of the Orange County Subdivision Code and Orange County Subdivision Manual, Subarticle 18. The Map to be submitted to the City of Newport Beach shall comply with the City's CADD Standards. Scanned images will not be accepted. 5. Prior to final building permit inspection, an agreement in a form approved by the City Attorney between the property owner and the City shall be executed and recorded waiving rights to the construction of future shoreline protection devices to address the threat of damage or destruction from waves, erosion, storm conditions, landslides, seismic activity, bluff retreat, sea level rise, or other natural hazards that may affect the property, or development of the property, today or in the future. The agreement shall be binding against the property owners and successors and assigns. 6. Prior to the issuance of a building permit, the property owner shall sign a notarized signed letter acknowledging all hazards present at the site, assuming the risk of injury or damage from such hazards, unconditionally waiving any claims of damage against the City from such hazards, and to indemnify and hold harmless City, its City Council, its boards and commissions, officials, officers, employees and agents from and against any and all claims, demands, obligations, damages, actions, causes of action, suits, losses, judgements, fines, penalties, liabilities, costs and expenses (including without limitation, attorney’s fees, disbursements and court costs) of every kind and nature whatsoever which may arise from or in any manner relate (directly or indirectly) to City’s approval of development. The letter shall be scanned into the plan set prior to building permit issuance. 25 Zoning Administrator Resolution No. ZA2019-### Page 6 of 7 7. Prior to the issuance of a building permit, a copy of the Resolution, including conditions of approval Exhibit “A,” shall be incorporated into the Building Division and field sets of plans. 8. The project is subject to all applicable City ordinances, policies, and standards, unless specifically waived or modified by the conditions of approval. 9. The applicant shall comply with all federal, state, and local laws. Materia l violation of any of those laws in connection with the use may be cause for revocation of this Coastal Development Permit. 10. This Coastal Development Permit may be modified or revoked by the Zoning Administrator if determined should they determine that the proposed uses or conditions under which it is being operated or maintained is detrimental to the public health, welfare or materially injurious to property or improvements in the vicinity or if the property is operated or maintained so as to constitute a public nuisance. 11. Should the property be sold or otherwise come under different ownership, any future owners or assignees shall be notified of the conditions of this approval by either the current business owner, property owner or the leasing agent. 12. No demolition or construction materials, equipment debris or waste shall be placed or stored in a location that would enter sensitive habitat, receiving waters, or a storm drain, or result in impacts to environmentally sensitive habitat areas, streams, wetland or their buffers. 13. Trash and debris shall be disposed in proper trash and recycling receptacles at the end of each construction day. Solid waste, including excess concrete, shall be disposed in adequate disposal facilities at a legal disposal site or recycled at a recycling facility. Prior to issuance of a building permit, the applicant shall submit a final construction erosion control plan. The plan shall be subject to review and approval by the Building Division. 14. Prior to issuance of a building permit, the applicant shall submit a final construction erosion control plan. The plan shall be subject to review and approval by the Building Division. 15. All landscape materials and irrigation systems shall be maintained in accordance with the approved landscape plan. All landscaped areas shall be maintained in a healthy and growing condition and shall receive regular pruning, fertilizing, mowing, and trimming. All landscaped areas shall be kept free of weeds and debris. All irrigation systems shall be kept operable, including adjustments, replacements, repairs, and cleaning as part of regular maintenance. 16. Prior to issuance of a building permit, the applicant shall pay any unpaid administrative costs associated with the processing of this application to the Planning Division. 17. The discharge of any hazardous materials into storm sewer systems or receiving waters shall be prohibited. Machinery and equipment shall be maintained and washed in confined areas specifically designed to control runoff. A designated fueling and vehicle maintenance 26 Zoning Administrator Resolution No. ZA2019-### Page 7 of 7 area with appropriate berms and protection to prevent spillage shall be provided as far a Debris from demolition shall be removed from work areas each day and removed from the project site within 24 hours of the completion of the project. Stockpiles and construction materials shall be covered, enclosed on all sites, not stored in contact with the soil, and located as far away as possible from drain inlets and any waterway from storm drain systems or receiving waters as possible. 18. To the fullest extent permitted by law, applicant shall indemnify, defend and hold harmless City, its City Council, its boards and commissions, officials, officers, employees, and agents from and against any and all claims, demands, obligations, damages, actions, causes of action, suits, losses, judgments, fines, penalties, liabilities, costs and expenses (including without limitation, attorney’s fees, disbursements and court costs) of every kind and nature whatsoever which may arise from or in any manner relate (directly or indirectly) to City’s approval of South Bayfront Waterpointe, LLC. Residences including, but not limited to, Coastal Development Permit No. CD2019-015 (PA2019-062). This indemnification shall include, but not be limited to, damages awarded against the City, if any, costs of suit, attorneys' fees, and other expenses incurred in connection with such claim, action, causes of action, suit or proceeding whether incurred by applicant, City, and/or the parties initiating or bringing such proceeding. The applicant shall indemnify the City for all of City's costs, attorneys' fees, and damages which City incurs in enforcing the indemnification provisions set forth in this condition. The applicant shall pay to the City upon demand any amount owed to the City pursuant to the indemnification requirements prescribed in this condition. 27 Attachment No. ZA 3 Vicinity Map 28 VICINITY MAP Tentative Parcel Map No. NP2019-004 Coastal Development Permit Nos. CD2019-015 and CD2019-016 PA2019-062 and PA2019-063 400 and 402 South Bay Front Subject Property 29 Attachment No. ZA 4 Tentative Parcel Map 30 31 Attachment No. ZA 5 Project Plans 32 Name Elevation A101 1 SIM Room name 150 SF 101 1i ? 90 00' 00" Distance N E 1 1 A101 SIM R @ 7 1/2"20 1i NORTH ARROW PROPERTY LINE TAG SECTION INDICATOR ROOM TAG (NAME / AREA) CALL-OUT TAG ELEVATION INDICATOR KEYNOTE TAG WINDOW TAG DOOR TAG WALL TAG REVISION FLAG STAIR TAG (NO. OF RISER & HEIGHT) ALUMINUM CONCRETE EARTH GYPSUM -PLASTER INSULATION -RIGID MASONRY -BRICK/STONE MASONRY -CONCRETE BLOCK PLYWOOD / GLU-LAM TIMBER SAND STEEL WOOD JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONSOWNER INFORMATION:PROJECT NAME STATUS These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT T-1.0 05/01/2019 2018-30TITLE SHEETBAY FRONT TRADITIONAL BAY FRONTTRADITIONALSOUTH BAYFRONTWATERPOINTE, LLC.610 NEWPORT CENTERDRIVE, SUITE 890,NEWPORT BEACH, CA92660FIRST CHECK 400 S BAY FRONTNEWPORT BEACH, CA 92662CAITLIN SMITH JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONSOWNER INFORMATION:PROJECT NAME STATUS These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT T-1.0 05/01/2019 2018-30TITLE SHEETBAY FRONT TRADITIONAL BAY FRONTTRADITIONALSOUTH BAYFRONTWATERPOINTE, LLC.610 NEWPORT CENTERDRIVE, SUITE 890,NEWPORT BEACH, CA92660FIRST CHECK 400 S BAY FRONTNEWPORT BEACH, CA 92662CAITLIN SMITH REF. 8/T-1.0FLOOR AREA HEIGHT NBMC (NEWPORT BEACH MUNICIPAL CODE) CALIFORNIA CODES: 2016 CBC, 2016 CFC, 2016 CEC, 2016 CPC, AND 2016 CMC, 2016 CAL GREEN R-3 / U 1-HR. CODES: OCCUPANCY CLASSIFICATION OCCUPANCY SEPARATIONS (GARAGE) OCCUPANT LOAD TYPE OF CONSTRUCTION OWNER: ARCHITECT: N/AALLOWABLE BLDG. AREA (PER CBC TBL. 503) FLOOR & FLOOR-CEILINGS N/A BRANDON ARCHITECTS, INC. CHRISTOPHER BRANDON 151 KALMUS DR. STE. G-1 COSTA MESA, CA 92626 P: 714.754.4040 WWW.BRANDONARCHITECTS.COM STRUCTURAL ENGINEER:CIVIL ENGINEER: GENERAL CONTRACTOR:LANDSCAPE DESIGNER: SURVEYOR:SOILS ENGINEER:SITE 1 UNIT V-B -SPRK'R. 3 STORY THE SUBJECT PROPERTY IS LOCATED IN NEWPORT BEACH, CA ON BALBOA ISLAND ON SOUTH BAY FRONT WEST OF THE FERRY TERMINAL. THE EXISTING LOT IS 30' WIDE BY APPROX. 86' DEEP AND ZONED R-BI (BALBOA ISLAND) AND APPROX. 2,591 S.F. CLIENT PROPOSES TO BUILD A NEW 3 STORY SINGLE FAMILY RESIDENCE APPROX. 2,743 S.F. LIVING AND 464 S.F. GARAGE. THE FIRST FLOOR PROGRAM INCLUDES BUT NOT LIMITED TO: EAT-IN KITCHEN W/. ISLAND & PANTRY, GREAT ROOM W/. FIREPLACE, DINING AREA (ALL OPEN), POWDER ROOM, 2 CAR GARAGE. SECOND FLOOR PROGRAM INCLUDES: MASTER SUITE, MASTER BATH AND WALK IN CLOSET, 2 SECONDARY BEDROOMS WITH ATTACHED BATHS & CLOSETS, LAUNDRY ROOM AND ELEVATOR. THIRD FLOOR WILL CONSIST OF A BONUS ROOM WITH SECONDARY POWDER AND FRONT AND BACK EXTERIOR DECKS WITH AN OUTDOOR BBQ COUNTER AND EXTERIOR AMENITIES. DESIGN WITH BE OF TRADITIONAL CAPE COD THEMED FOCUSING ON EXTERIOR VIEWS OF THE BAYFRONT. EXTERIOR MATERIALS TO BE OF HIGH QUALITY AND DURABILITY INCLUDING NATURAL WOOD SHINGLES, EXTERIOR COMPOSITE WOOD SIDING, NATURAL SHINGLE ROOFING AND METAL ROOFING ACCENTS. FIRE SPRINKLER: NFPA 13D YES DEFERRED SUBMITTALS 8PROJECT STATISTICS 5 3 1 249 10 AGENCIES & PUBLIC SERVICES VICINITY MAP/ PROJECT DESCRIPTION MATERIAL LEGEND ANNOTATION LEGEND CODE REVIEW SHEET LISTSITE INFORMATION11 7 6SPECIAL INSPECTIONS PROJECT DIRECTORYPROJECT DIRECTORY PROJECT DESCRIPTION: BAY FRONT TRADITIONAL BRANDON ARCHITECTS, INC.SOUTH BAYFRONT WATERPOINTE, LLC MR. GARRETT CALACCI, PRESIDENT 610 NEWPORT CENTER DR. SUITE 890 NEWPORT BEACH, CA 92660 P: 949.644.8900 WATERPOINTE PROPERTIES, LLC MR. GARRETT CALACCI, PRESIDENT 610 NEWPORT CENTER DR. SUITE 890 NEWPORT BEACH, CA 92660 P: 949.644.8900 TBD BUILDING AREA SCHEDULE Name AREA COMMENTS FIRST FLOOR 1029 SF SECOND FLOOR 1421 SF THIRD FLOOR 275 SF 2724 SF GARAGE 464 SF 464 SF GRAND TOTAL 3188 SF OUTDOOR AREA SCHEDULE NAME AREA COMMENTS ENTRY 53 SF COVERED VIEW DECK 459 SF ROOF DECK 198 SF 710 SF PATIO 214 SF PARTIALLY COVERED M. BALCONY 264 SF COVERED 478 SF GRAND TOTAL 1188 SF APEX LAND SURVEYING, INC. PAUL CRAFT, LIC. NO. 8516 HUNTINGTON BEACH, CA 92646 P: 714.488.5006 F: 714.333.4440 FARHAD MANSHADI, LIC. NO. C36840 ESI/FME, INC. 1800 E. 16TH ST., STE. B SANTA ANA, CA 92701 P: 714.835.2800 F: 714.835.2819 EGA CONSULTANTS, LLC. 375-C MONTE VISTA AVE. COSTA MESA, CA 92627 P.949.642.9303 PROJECT NO. WP126.1 DATED: JULY 5TH, 2018 FORKETT ENGINEERING TOM RUIZ P: 714 963 6793 22311 BROOKHURST ST. HUNTINGTON BEACH, CA 92646 SHEET #DRAWING TITLE T-1.0 TITLE SHEET T-1.1 GENERAL ARCHITECTURAL NOTES T-1.2 SUPPLEMENTAL NOTES & DOCUMENTS SUR TOPOGRAPHIC SURVEY A-0.0 ARCHITECTURAL SITE PLAN A-0.1 BUILDING AREA PLANS A-0.3 SLAB EDGE PLAN G-01 GRADING COVER SHEET G-02 PRECISE GRADING PLAN G-03 GRADING DETAILS G-04 EROSION CONTROL PLAN L-1 LANDSCAPE PLAN (REF. ONLY) A-1.0 3-DIMENSIONAL VIEWS A-2.0 FLOOR PLAN A-3.0 ROOF PLAN A-4.0 EXTERIOR ELEVATIONS & MATERIAL SCHEDULE A-5.0 BUILDING SECTIONS A-5.1 BUILDING SECTIONS A-6.0 REFLECTED CEILING PLANS A-7.0 DOOR & WINDOW SCHEDULES & DETAILS AD-1 ARCHITECTURAL DETAILS S0 STRUCTURAL TITLE SHEET SGN STRUCTURAL NOTES S1 FOUNDATION PLAN S2 FRAMING PLAN FD1 FOUNDATION DETAILS SD1 STRUCTURAL DETAILS HFX1 HFX PANELS-TYP. FOUNDATION DETAILS HFX2 HFX PANELS-TYP. FRAMING DETAILS PLUM PLUMBING MECH MECHANICAL E-1 SCHEMATIC ELECTRICAL PLANS T-24 ENERGY CALCULATIONS INTERIOR DESIGNER: TBD DIG ALERT: 1.800.227.2600 SOUTHERN CALIFORNIA EDISON: 1.714.895.0246 SOUTHERN CALIFORNIA GAS: 1.800.427.2000 CITY WATER & SEWER: 1.949.644.3011 PACIFIC BELL TELEPHONE: 1.800.750.2355 CITY OF NEWPORT BEACH PUBLIC WORKS DEPT.: 1.949.644.3311 CITY OF NEWPORT BEACH PLANNING DEPT.: GENERAL INFORMATION: 1.949.644.3200 ZONING INFORMATION:1.949.644.3204 CITY OF NEWPORT BEACH BUILDING DEPT.: GENERAL:1.949.644.3275 PERMITS:1.949.644.3288 INSPECTIONS:1.949.644.3255 NEWPORT BEACH FIRE DEPARTMENT:1.949.644.3106 ORANGE COUNTY HEALTH SERVICES:1.714.834.3882 LEGAL DESCRIPTION: LOT INFORMATION: ZONED: R-BI SITE AREA:2630 S.F. BUILDABLE AREA: 1992 S.F. TOTAL ALLOWABLE AREA: 1.5 x 1992 S.F. = 2988 S.F. +200 S.F. = 3188 S.F. REQ'D OPEN VOLUME = 1992 S.F. X .15 = 298.8 S.F. (7'-6" HT MIN.) OPEN VOLUME PROVIDED = 478 > 298.8 S.F. EXISTING BUILDING INFORMATION: EXISTING MULTI FAMILY W/ GARAGE TO BE DEMOLISHED EXISTING S.F. = 1,842.37 S.F. (FOOTPRINT) ZONING INFORMATION: FRONT SETBACK: 0 FT. REAR SETBACK: 5 FT. LEFT SETBACK: 3 FT. RIGHT SETBACK: 3 FT. BUILDABLE AREA: 1,992 S.F. APN: 050-043-13 LOT 1 BLOCK 7 OF SECTION 1, BALBOA ISLAND, IN THE CITY OF NEWPORT BEACH, COUNTY OF ORANGE, STATE OF CALIFORNIA,AS PER MAP RECORDED IN BOOK 6, PAGE 30 OF MISCELLANEOUS MAPS, RECORDS OF ORANGE COUNTY, CALIFORNIA. 400 S. BAYFRONT, NEWPORT BEACH, CA 92662 TITLE 24 CONSULTANT: HERITAGE ENGERGY GROUP LLC RUDY SAINS 470 WALD, IRVINE, CA 92618 P:949.789.7221 NOTE: DEFERRED SUBMITTALS TO BE REVIEWED BY PROJECT ARCHITECT OR ENGINEER OF RECORD AND CERTIFIED PRIOR TO SUBMITTAL TO LOCAL AGENCY FOR REVIEW. C.N.B. NOTE:CHRISTOPHER BRANDON, PRINCIPAL ARCHITECT IS THE DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE OF THE PROJECT, RESPONSIBLE FOR REVIEWING AND COORDINATING SUBMITTAL DOCUMENTS PREPARED BY OTHERS, INCLUDING PHASED AND DEFERRED SUBMITTAL ITEMS, FOR COMPATIBILITY WITH THE DESIGN OF THE BUILDING. (NBMC 15.02.010) 1.LANDSCAPE PLAN; BBQ; FIRE PIT; ACCESSORY STRUCTURES, MASONRY OR CONCRETE WALLS/FENCES; RETAINING WALLS OVER 4 FT. HIGH FROM THE BOTTOM OF THE FOUNDATION TO THE TOP OF WALL; UNDER SEPARATE SUBMITTAL (FOR H.O.A. PURPOSES). 2. POOLS, SPAS, WALLS, FENCES, PATIO COVERS AND OTHER FREESTANDING STRUCTURES REQUIRE SEPARATE REVIEWS AND PERMITS. 3. SUBMIT SOUND ATTENUATION DESIGN FOR HVAC EQUIPMENT PER ARI STD. 275. SOUND LEVEL NOT TO EXCEED 50dBA (55dBA WITH TIMER, 65dBA WITH TIMER AND NEIGHBORS CONSENT). LOCATION OF MEASUREMENT TO BE AT ADJACENT PROPERTY PATIO OR OPENING. 4. A CAL-OSHA PERMIT IS REQUIRED FOR EXCAVATIONS DEEPER THAN 5' AND FOR SHORING AND UNDERPINNING. CONTRACTOR TO PROVIDE A COPY OF OSHA PERMIT. 5. FIRE SPRINKLERS REQUIRED, CONTRACTOR TO SUBMIT FIRE SPRINKLER DRAWINGS FOR ARCHITECT'S APPROVAL PRIOR TO SUBMITTING TO CITY. OBTAIN FIRE SPRINKLER PERMIT PRIOR TO CALLING FOR ROOF SHEATHING INSPECTION. 6. GLASS GUARD/HANDRAILS 1. REF. STRUCT. SHTS. FOR SPECIAL INSPECTION BY ENGINEER OF RECORD 2. HERS VERIFICATION REQUIRED, REF. T-24 ENERGY CALCULATIONS TOTAL LIVING TOTAL GARAGE NO. REVISION DATENO. REVISION DATE TOTAL OPEN SPACE TOTAL OUTDOOR LANDSCAPE AREA SCHEDULE NAME AREA COMMENTS L1 118 SF L2 61 SF L3 62 SF GRAND TOTAL 242 SF 33 JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONSOWNER INFORMATION:PROJECT NAME STATUS These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT T-1.1 03/22/2019 2018-30GENERAL ARCHITECTURAL NOTESBAY FRONT TRADITIONAL BAY FRONTTRADITIONALSOUTH BAYFRONTWATERPOINTE, LLC.610 NEWPORT CENTERDRIVE, SUITE 890,NEWPORT BEACH, CA92660CDP -FIRST CHECK 400 S BAY FRONTNEWPORT BEACH, CA 92662CAITLIN SMITH 1GENERAL NOTES ABBREVIATIONS 2 DEFINITIONS: SPECIFICATIONS SHALL MEAN: WRITTEN SPECIFICATIONS IN THE PLANS OR THE "PROJECT MANUAL" (IF PROVIDED FOR THIS PROJECT) CONTRACT DOCUMENTS SHALL MEAN: WORKING DRAWINGS APPROVED FOR BUILDING PERMIT, PLUS ANY CHANGE ORDERS OR ADDENDA TO SAME. CONTRACTOR SHALL MEAN: SOUTH BAYFRONT WATERPOINTE, LLC ARCHITECT SHALL MEAN: BRANDON ARCHITECTS, INC., CHRISTOPHER BRANDON PRINCIPAL OWNER SHALL MEAN: (AS USED IN THESE SPECIFICATIONS) LICENSED GENERAL CONTRACTOR HIRED TO PERFORM THE WORK UNDER THIS CONTRACT 1. CODES/GENERAL PROVISIONS: ALL WORK, CONSTRUCTION AND MATERIALS SHALL COMPLY WITH ALL PROVISIONS OF THE APPLICABLE BUILDING CODES AND WITH OTHER RULES, REGULATIONS AND ORDINANCES GOVERNING THE PLACE OF CONSTRUCTION. IT IS THE RESPONSIBILITY OF THE CONTRACTOR, SUB-CONTRACTORS, AND ANYONE SUPPLYING LABOR AND/OR MATERIAL TO BRING TO THE ATTENTION OF THE ARCHITECT (VERBALLY AND IN WRITING) ANY KNOWN DISCREPANCIES OR CONFLICT BETWEEN THE REQUIREMENTS OF THESE CODES AND THE CONTRACT DOCUMENTS (DRAWINGS). THE APPLICABLE CODES SHALL INCLUDE, BUT SHALL NOT BE LIMITED TO THOSE AS LISTED IN "CODE REVIEW" BOX. (T-1) ALL WORK SHALL BE PERFORMED SO AS TO COMPLY WITH ALL LEGAL AND INDUSTRY REQUIREMENTS AND STANDARDS INCLUDING THE FOLLOWING: THE BUILDING CODES, 2016 EDITIONS, AS ADOPTED BY CALIFORNIA, ALL APPLICABLE RELATED SPECIALTY CODES. THE FUNCTIONALITY STANDARDS SET FORTH IN TITLE 7 OF THE CALIFORNIA CIVIL CODE (THE "RIGHT TO REPAIR ACT"). ANY WORK TIME RESTRICTIONS IMPOSED BY THE CITY OF NEWPORT BEACH. THE MANUFACTURER'S REQUIREMENTS OF RECOMMENDATIONS FOR ANY INCORPORATED PRODUCTS. 2. FEES: CONTRACTOR AND HIS SUB-CONTRACTORS SHALL OBTAIN AND PAY FOR ALL PERMITS, LICENSES, CONSTRUCTION TAXES AND FEES REQUIRED BY CITY, COUNTY AND STATE LAWS EXCEPT THE GENERAL BUILDING PLAN CHECK FEE AND REQUIRED REFUNDABLE DEPOSITS WHICH WILL BE PAID BY THE OWNER. CONTRACTOR SHALL ARRANGE FOR ALL METER INSTALLATIONS AND PAY ALL FEES FOR SAID METERS. CONTRACTOR SHALL PROVIDE TEMPORARY TOILET FACILITIES AND EROSION CONTROL MEASURES AS REQUIRED BY STATE AND LOCAL BUILDING CODE. 3. CONTRACTOR'S SURVEY: CONTRACTOR SHALL VISIT THE JOB SITE AND BE RESPONSIBLE FOR HAVING COMPLETE KNOWLEDGE OF EXISTING CONDITIONS. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS WITH THOSE SHOWN ON THE DRAWINGS AND SHALL VERIFY GRADES, CONDITIONS AND DIMENSIONS PRIOR TO COMMENCING DEMOLITION AND CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY VERBALLY AND IN WRITING OF DISCREPANCIES BETWEEN ACTUAL CONDITIONS AND THOSE DEPICTED IN THE CONTRACT DOCUMENTS. CONTRACTOR SHALL NOTIFY ARCHITECT IMMEDIATELY VERBALLY AND IN WRITING OF ANY DISCREPANCIES FOUND WITHIN THE DRAWINGS AND SPECIFICATIONS. 4. COORDINATION OF CONSTRUCTION: CONTRACTOR IS SOLELY RESPONSIBLE FOR THE ACCURACY OF DETAILS; FOR CONFIRMING AND COORDINATING ALL QUANTITIES AND DIMENSIONS; FOR SELECTING FABRICATION PROCESSES; FOR TECHNIQUES OF ASSEMBLY AND PERFORMANCE OF ALL WORK IN A SAFE AND SATISFACTORY MANNER. CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF ALL WORK INCLUDING THAT OF THE SUB-CONTRACTORS. CONTRACTOR SHALL PROVIDE SUPERVISION OF THE JOB DURING ALL PHASES OF CONSTRUCTION ACTIVITIES. A COMPETENT SUPERINTENDENT SHALL BE SELECTED BY THE CONTRACTOR AND SHALL BE IN CHARGE OF THE JOB UNTIL ITS COMPLETION. CONTRACTOR AGREES TO BIND EVERY SUB-CONTRACTOR BY THE TERMS OF THE CONTRACT AS FAR AS SUCH TERMS ARE APPLICABLE TO THE SUB-CONTRACTOR'S WORK. 5. CLEAN-UP: ALL SUB-CONTRACTORS SHALL BE RESPONSIBLE FOR THE DAILY REMOVAL OF ALL DEBRIS ACCUMULATED AS A RESULT OF THEIR OPERATIONS. ALL SCRAP DEBRIS AND OTHER EXCESS MATERIAL SHALL BE LAWFULLY REMOVED FROM THE SITE, UNLESS OTHERWISE DIRECTED BY THE CONTRACTOR. 6. TESTS AND PERMITS: CONTRACTOR SHALL ARRANGE FOR, AND SECURE REQUIRED TESTS, PERMITS AND INSPECTIONS, AND SHALL BEAR COSTS FOR SAME. 7. GUARANTEES: CONTRACTOR SHALL GUARANTEE ALL WORK, MATERIALS AND PRODUCTS FOR ONE YEAR AFTER THE DATE OF ACCEPTANCE OF THE WORK AND CONTRACTOR SHALL REPAIR OR REPLACE, OR CAUSE TO BE REPAIRED OR REPLACED ANY OR ALL SUCH WORK TOGETHER WITH ANY OTHER WORK WHICH MAY BE DISPLACED IN DOING SO, THAT MAY PROVE DEFECTIVE WITHIN ONE YEAR, WITHOUT ADDITIONAL EXPENSE; ORDINARY WEAR AND TEAR, UNUSUAL ABUSE OR NEGLECT IS EXCEPTED. EXCEPTIONS TO ONE YEAR GUARANTEE ARE SPECIFIED IN OTHER SECTIONS OF THE PROJECT MANUAL OR DRAWINGS. STATE LAW, OR MANUFACTURER'S GUARANTEE SHALL GOVERN IF LENGTH AND TYPES OF GUARANTEES ARE MORE STRICT OR FOR LONGER PERIODS. IT IS UNDERSTOOD BY CONTRACTOR THAT IT IS HIS RESPONSIBILITY TO PROVIDE MATERIALS AND CONSTRUCTION WHICH WILL YIELD A REASONABLE VALUE OVER A PERIOD OF TIME WHICH MAY EXCEED THE SPECIFIED GUARANTEE AND WARRANTY PERIODS. CONTRACTOR SHALL BE RESPONSIBLE FOR A WEATHER TIGHT BUILDING, FREE FROM DEFECTS OF MATERIALS AND WORKMANSHIP. EACH SUB-CONTRACTOR SHALL PROVIDE A WRITTEN GUARANTEE STATING THAT WORK EXECUTED BY HIM IS FREE AND WILL REMAIN FREE FROM DEFECTS OF MATERIALS AND WORKMANSHIP FOR ONE YEAR FROM DATE OF ACCEPTANCE OF HIS WORK BY OWNER, AND THAT REPAIR AND REPLACEMENT OF SUCH DEFECTIVE WORK AND ALL OTHER WORK DAMAGED AS A RESULT THEREBY WILL BE EXECUTED IN A TIMELY MANNER AT THE CONVENIENCE OF THE OWNER AND WITHOUT COST TO OWNER. 8. WAIVER OF LIENS: CONTRACTOR SHALL PROVIDE CERTIFIED RELEASE OF LIENS BY ALL SUB-CONTRACTORS AND SUPPLIERS, OR ANYONE PROVIDING MATERIALS AND/OR LABOR AS THEY BECOME AVAILABLE. 9. ROLL OF ARCHITECT DURING CONSTRUCTION: THE ARCHITECT WILL NOT ACT AS THE OWNER'S REPRESENTATIVE DURING CONSTRUCTION. ARCHITECT WILL ADVISE AND CONSULT WITH OWNER. ARCHITECT WILL OBSERVE CONSTRUCTION PER HIS AGREEMENT WITH OWNER AND RENDER INTERPRETATIONS NECESSARY FOR THE PROPER EXECUTION OR PROGRESS OF THE WORK IN ACCORDANCE WITH THE INTENT OF THE PLANS AND SPECIFICATIONS. ARCHITECT WILL NOT BE RESPONSIBLE OR HAVE CONTROL OR CHARGE OVER THE ACTS OR OMISSIONS, CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS, OF THE CONTRACTOR, SUB-CONTRACTORS, OR ANY OF THEIR AGENTS OR EMPLOYEES, OR ANY OTHER PERSONS PERFORMING ANY OF THE WORK. ANY VERBAL INSTRUCTION OR AUTHORIZATION THAT IS CONFIRMED BY LETTER, MEETING NOTE, MEMORANDA, OR THE LIKE, (WITH A COPY SENT TO THE OWNER, OR THE OWNER'S REPRESENTATIVE) & THERE IS NO EXCEPTION TAKEN WITHIN (10) CALENDAR DAYS, SHALL BE DEEMED EQUIVALENT TO RECEIPT OF WRITTEN INSTRUCTION, APPROVAL AND AUTHORIZATION FROM THE OWNER. 10. A.I.A. GENERAL CONDITIONS: THE CURRENT GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION PUBLISHED BY THE AMERICAN INSTITUTE OF ARCHITECTS SHALL APPLY AS THOUGH IT WERE PART OF THESE DOCUMENTS UNLESS SPECIFICALLY MODIFIED IN THE OWNER/CONTRACTOR AGREEMENT. A COPY OF SAID GENERAL CONDITIONS MAY BE OBTAINED FROM THE ARCHITECT UPON REQUEST. THE NOTES CONTAINED IN THESE "GENERAL NOTES" ON THIS SHEET ARE INTENDED TO SUMMARIZE AND COMPLIMENT THE A.I.A. GENERAL CONDITIONS. THE A.I.A. GENERAL CONDITIONS SHALL TAKE PRECEDENCE OVER THESE NOTES SHOULD A CONFLICT IN WORDING OCCUR. 11. EXTRAS: OWNER MAY ORDER EXTRA WORK OR MAKE CHANGES BY ALTERING, ADDING TO OR DEDUCTING FROM THE WORK, THE CONTRACT SUM BEING ADJUSTED TO THE MUTUAL SATISFACTION OF THE OWNER, ARCHITECT AND CONTRACTOR. BEFORE ANY CHANGES ARE BEGUN, THE ADDED OR DEDUCTED SUM SHALL BE PRESENTED TO OWNER IN WRITING FOR APPROVAL. 12. SUBSTITUTIONS: SUBSTITUTIONS OF MATERIALS OR METHODS PROPOSED BY THE CONTRACTOR OR HIS SUB-CONTRACTORS CONTRARY TO DRAWINGS AND SPECIFICATIONS SHALL BE SUBMITTED TO ARCHITECT IN WRITING FOR APPROVAL OR DENIAL. IF MORE THAN ONE MANUFACTURER IS SPECIFIED IN THE PLANS OR SPECIFICATIONS, IT SHALL BE THE CONTRACTOR'S OPTION TO SELECT THE ONE WHICH HE MAY DESIRE. IF MORE THAN ONE FINISH OR STYLE IS AVAILABLE IN THE ITEM SPECIFIED, CONTRACTOR SHALL BE OBLIGATED TO NOTIFY ARCHITECT VERBALLY AND IN WRITING OF THIS FACT FOR ARCHITECT'S AND OWNER'S DECISION. WHERE THE TERM "OR EQUAL" IS USED IN DRAWINGS OR SPECS IT SHALL BE UNDERSTOOD THAT THE REFERENCE IS MADE SUBJECT TO THE RULING AND JUDGMENT OF THE ARCHITECT AND SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW AND APPROVAL. ACTUAL SAMPLES OF THE SUBSTITUTIONS SHALL ALSO BE SUBMITTED TO THE ARCHITECT FOR REVIEW AND APPROVAL. 13. INSURANCE: CONTRACTOR SHALL CARRY GENERAL LIABILITY INSURANCE WITH BROADFORM PROPERTY DAMAGE ENDORSEMENT AND CONTINGENT LIABILITY ENDORSEMENT. OWNER AND ARCHITECT SHALL BE LISTED AS ADDITIONAL INSURERS UNDER THE POLICY WITH WAIVER OF SUBROGATION. CONTRACTOR SHALL FURNISH OWNER WITH A CERTIFICATE OF INSURANCE WITH A 30 DAY NOTICE OF CANCELLATION. OWNER SHALL OBTAIN A BUILDER'S RISK POLICY WITH ARCHITECT NAMED AS AN ADDITIONAL INSURED WITH WAIVER OF SUBROGATION. 14. SCOPE OF DRAWINGS AND SPECIFICATIONS: THESE DRAWINGS AND SPECIFICATIONS SHALL BE INTENDED TO SHOW AND DESCRIBE DETAILS FOR A CONSTRUCTIBLE BUILDING. PARTS AND DETAILS NOT FULLY SHOWN OR DESCRIBED SHALL BE DETAILED AND EXECUTED ACCORDING TO STANDARD FIRST CLASS PRACTICE AND IN SIMILAR MANNER AND SPIRIT OF THE DETAILS WHICH ARE SHOWN ON THE DRAWINGS AND/OR DESCRIBED IN THE PROJECT MANUAL. IF CONTRACTOR OR SUB-CONTRACTOR FINDS ANY DETAILS WHICH, IN HIS OPINION, ARE UNSOUND, UNSAFE, OR NOT WATERPROOF, IT IS HIS DUTY TO NOTIFY ARCHITECT IN WRITING OF THIS FACT. IF WORK IS PERFORMED AS DETAILED, IT WILL BE ASSUMED THAT THERE ARE NO OBJECTIONS TO THE DETAIL. ACCURACY OF ALL DIMENSIONS SHALL BE CHECKED. NO EXTRA COMPENSATION WILL BE ALLOWED FOR DIFFERENCE BETWEEN ACTUAL DIMENSIONS AND THOSE INDICATED ON THE DRAWINGS. IN USING THESE PLAN FOR BIDDING OR CONSTRUCTION PURPOSES, ALL CONTRACTORS ARE REQUIRED TO REVIEW AND TREAT THEM AS A WHOLE IN ORDER TO IDENTIFY ALL REQUIREMENTS THAT DIRECTLY OR INDIRECTLY AFFECT THEIR PORTION OF THE WORK, EVEN REQUIREMENTS LOCATED IN SECTIONS DESIGNATED AS APPLICABLE TO OTHER TRADES. IN CASE OF CONFLICTS, THE AFFECTED CONTRACTOR IS REQUIRED TO EITHER OBTAIN DIRECTION FROM AN APPROPRIATE REPRESENTATIVE OF THE OWNER, OR OTHERWISE TO APPLY THE MORE STRINGENT STANDARD. THESE PLANS ARE INTENDED TO SET FORTH THE REQUIREMENTS FOR CONSTRUCTION IN ONLY AN INDUSTRY-STANDARD LEVEL OF QUALITY AND DETAIL, AND THE ARE INTENDED TO BE SUPPLEMENTED BY APPROPRIATE REQUESTS FOR CLARIFICATION AND INFORMATION. ERRORS AND OMISSIONS ARE TO BE EXPECTED AND ANTICIPATED, AND ALL CONTRACTORS ARE REQUIRED TO CAREFULLY REVIEW THESE PLANS FOR ERRORS AND OMISSIONS AND TO BRING THESE ERRORS AND OMISSIONS TO THE ATTENTION OF A APPROPRIATE OWNER & ARCHITECT IN WRITING IN A TIMELY MANNER; AND ANY CONTRACTOR WHO FAILS TO DO SO BEFORE BIDDING OR OTHERWISE PROCEEDING ASSUMES THE RISK OF ANY CONSEQUENCES. SCALED DIMENSIONS SHOULD BE CONSIDERED ONLY APPROXIMATE; AND IN ANY DIMENSIONS BEFORE PROCEEDING WITH ANY AFFECTED PROCUREMENT, FABRICATION OR CONSTRUCTION. SCHEMATIC PLANS ARE INTENDED ONLY TO DEMONSTRATE THE RELATIONSHIP AMONG COMPONENT PARTS, AND NOT TO DEPICT SPECIFIC LOCATIONS (e.g. SCHEMATIC ELECTRICAL PLANS). 15. DIMENSIONS ON DRAWINGS: FIGURED DIMENSIONS SHALL BE FOLLOWED IN PREFERENCE TO SCALE, AND DETAIL DRAWINGS IN PREFERENCE TO SMALL SCALE DRAWINGS. SUB-CONTRACTOR AND CONTRACTOR SHALL CHECK ACCURACY OF ALL DIMENSIONS IN THE FIELD PRIOR TO ANY WORK BEING CONSTRUCTED OR MATERIALS OR PRODUCTS FABRICATED OR ORDERED. SPECIFICATIONS AND WRITTEN NOTES AND SCHEDULES ON DRAWINGS SHALL BE FOLLOWED IN PREFERENCE TO INFORMATION FURNISHED IN THE FORM OF LINE DRAWINGS. DETAILED DRAWINGS FURNISHED DURING CONSTRUCTION OR APPROVED BY CONTRACTOR OR ARCHITECT ARE TO BE CONSIDERED EXPLANATORY AND NOT AS CHANGES TO DRAWINGS AND SPECIFICATIONS. NOTES, FIGURES AND DETAILS ON SAID DRAWINGS SHALL BE FOLLOWED AND EXECUTED AS IF PART OF THESE DOCUMENTS. DRAWINGS ARE NOT TO BE SCALED UNLESS PERMITTED BY THE ARCHITECT. DIMENSIONS SHALL GOVERN. ALL EXTERIOR DIMENSIONS ARE BASED ON NOMINAL SIZES OF MEMBERS AND ARE GIVEN TO THE OUTER FACE OF SUCH MEMBERS, UNLESS OTHERWISE NOTED ON DRAWINGS. INTERIOR PARTITIONS ARE DIMENSIONED FROM FACE OF STRUCTURE TO FACE OF STRUCTURE UNLESS OTHERWISE NOTED ON DRAWINGS. WHERE DIMENSION IS LABELED "CLEAR" IT IS TAKEN FROM THE FACE OF FINISH TO FACE OF FINISH OF EACH MATERIAL. PLUS OR MINUS (+/-) DIMENSIONS SHALL NOT VARY BY MORE THAN 2" WITHOUT APPROVAL BY ARCHITECT. WALL ANGLES ARE EITHER 90° OR 45° UNLESS NOTED OTHERWISE. 16. SUBMITTALS, MEETING NOTES, BULLETINS, AND MEMOS: SUBMITTALS WILL BE REVIEWED BY THE ARCHITECT, IF AT ALL, ONLY PURSUANT TO THE INDUSTRY-STANDARD PROTOCOL SET FORTH IN AIA DOCUMENT A201-1997; AND IN NO EVENT WILL THE SUBMITTAL REVIEW PROCESS RELIEVE OR LESSEN THE SUBMITTING CONTRACTOR'S RESPONSIBILITY FOR AN INAPPROPRIATE SUBMITTAL. ARCHITECT, FROM TIME TO TIME, WILL ISSUE CONSTRUCTION NOTES OR MEMOS REGARDING CONSTRUCTION ISSUES THAT HAVE ARISEN SINCE THE DRAWINGS AND SPECIFICATIONS WERE COMPLETED. CONTRACTOR SHALL REVIEW THESE WRITTEN DOCUMENTS AND INCORPORATE THEM INTO THE PROJECT. ANY QUESTIONS OR OBJECTIONS AS TO THE INTENT OF THE WRITTEN DOCUMENT ITEMS WILL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT FOR DISCUSSION AND OR CLARIFICATION. ANY ITEM THAT RESULTS IN A CHANGE TO THE COST OR TIMING OF THE PROJECT SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE OWNER & ARCHITECT PRIOR TO EXECUTING. CONTRACTOR SHALL SUBMIT FABRICATION SHOP DRAWINGS TO THE ARCHITECT FOR APPROVAL PRIOR TO ORDERING AND/OR FABRICATION. CONTRACTOR SHALL SUBMIT MANUFACTURER'S CUTS FOR ALL FIXTURES AND EQUIPMENT CALLED FOR ON THE CONSTRUCTION DOCUMENTS TO ARCHITECT INCLUDING BUT NOT LIMITED TO LIGHT FIXTURES, HARDWARE, PLUMBING FIXTURES, KITCHEN EQUIPMENT, ETC. BY SUBMITTING SHOP DRAWINGS AND PRODUCT DATA, THE CONTRACTOR REPRESENTS THAT HE/SHE HAS VERIFIED FIELD CONDITIONS, DIMENSIONS AND RELATED CONSTRUCTION AND HAS COORDINATED THE SUBMISSION CONSTRUCTION WITH THE REQUIREMENTS OF ALL OTHER RELATED WORK IN THE CONSTRUCTION DOCUMENTS. ALL SHOP DRAWINGS AND CUTS MARKED "REVIEWED" BY ARCHITECT, ARE FOR VERIFICATION OF ADHERENCE TO THE DESIGN INTENT ONLY. THE CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR ALL MEANS AND METHODS AND ERRORS AND OMISSIONS ON THEIR DRAWINGS. CONTRACTOR TO SUBMIT A COMPLETE SHOP DRAWINGS AND OR SUBMITTAL FOR APPROVAL BEFORE COMMENCING FABRICATION AND/OR INSTALLATION OF ALL APPLICABLE ITEMS. ALL SHOP DRAWINGS DIMENSIONS SHALL BE FIELD VERIFIED, REVIEWED AND APPROVED BY CONTRACTOR BEFORE SUBMITTAL. SHOP DRAWINGS WHICH ARE INCOMPLETE OR LACKING SUFFICIENT INFORMATION WILL BE RETURNED WITHOUT REVIEW. SUBMIT SAMPLES FOR INITIAL SELECTION PURPOSES OF ACTUAL VENEERS SHOWING A FULL RANGE OR GRAIN VARIATION, FINISH AND PATTERNS PROPOSED. SUBMIT SAMPLES AS REQUIRED UNTIL APPROVED BY ARCHITECT. SAMPLES SHALL BE 12" X 12" MIN., ONE UNIT OF EACH TYPE AND FINISH. 17. ERRORS AND OMISSIONS: ERRORS OR OMISSIONS WHICH APPEAR ON THE DRAWINGS, IN SPECIFICATIONS OR OTHER CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT BY THE CONTRACTOR AND TO THE CONTRACTOR BY THE SUB-CONTRACTOR IN WRITING. IN EVENT OF FAILURE OF SUB-CONTRACTOR TO GIVE SUCH WRITTEN NOTIFICATION BEFORE CONSTRUCTION OR FABRICATIONS OF THE WORK, HE WILL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY SUCH ERRORS OR OMISSIONS AND THE COSTS OF RECTIFYING SAME. HOWEVER, DRAWINGS AND SPECIFICATIONS ARE COMPLEMENTARY AND WORK CALLED FOR ON ONE AND NOT THE OTHER SHALL BE PROVIDED AS THOUGH FULLY SET FORTH IN BOTH. 18. BARRICADES: CONTRACTOR SHALL ERECT AND PROPERLY MAINTAIN AT ALL TIMES AS REQUIRED BY CONDITIONS AND PROGRESS OF THE WORK, ALL NECESSARY PROTECTIVE BARRICADES, FENCES AND OTHER SAFEGUARDS FOR THE PROTECTION OF THE WORKERS AND THE PUBLIC. THESE BARRICADES SHALL BE CONSTRUCTED AND BE LOCATED AS SHALL BE DETERMINED BY LOCAL AUTHORITIES AND CODES. 19. TEMPORARY BRACING: AT ALL TIMES DURING CONSTRUCTION ACTIVITIES OR ERECTION OF PROJECT OR ITS COMPONENT PARTS, PRIOR TO COMPLETION OF THE STRUCTURAL FRAME OR REPLACEMENT AND PERMANENT CONNECTION OF COMPONENT MEMBERS TO THE STRUCTURAL FRAME, SUB-CONTRACTORS SHALL PROVIDE, INSTALL AND MAINTAIN PROPERLY DESIGNED AND CONSTRUCTED TEMPORARY BRACING OF ADEQUATE STRENGTH TO PREVENT DISLOCATION, DISTORTION, CRACKING, FALLING OFF, OR ANY OTHER DAMAGE TO WORK OR ANY OF ITS COMPONENT PARTS DUE TO FORESEEABLE NORMAL AS WELL AS NOT FORESEEABLE EXCESSIVE WIND AND EARTHQUAKE FORCES WITHOUT ADDITIONAL COST TO OWNER. CONTRACTOR AND HIS SUB-CONTRACTORS SHALL, AT THEIR EXPENSE, REPLACE OR REPAIR, AS DIRECTED, DAMAGED PORTIONS OF THEIR WORK OR COMPONENT PARTS. 20. TOXIC SUBSTANCES REMOVAL: PRIOR TO ANY WORK BEING PERFORMED, WHENEVER THERE ARE EXISTING STRUCTURES TO BE REMOVED OR ALTERED, CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION AND REMOVAL OF ANY TOXIC MATERIALS OR SUBSTANCES AS REQUIRED BY THE STATE OF CALIFORNIA INCLUDING BUT NOT LIMITED TO ASBESTOS, LEAD PAINTS, MOLD, ETC. REMOVAL AND DISPOSAL SHALL FOLLOW STATE MANDATED METHODS, PROCEDURES, DOCUMENTATION AND APPLICATION REQUIREMENTS. 21. NO CHANGES ARE TO BE MADE ON THESE PLANS WITHOUT THE KNOWLEDGE OR CONSENT OF THE ARCHITECT/ ENGINEER WHOSE SIGNATURE APPEARS HERON. 22. NO FRAMING OF ANY TYPE TO BE CONCEALED PRIOR TO INSPECTION BY GOVERNING AGENCIES. 23. REFERENCES TO ANY DETAIL OR DRAWINGS IS FOR CONVENIENCE ONLY AND DOES NOT LIMIT THE APPLICATION OF SUCH DETAIL OR DRAWINGS. 24. USE 2x6 MINIMUM STUDS FOR PLUMBING WALLS 25. MAXIMUM FLOW RATE STANDARDS SET BY THE CURRENT CALIFORNIA GREEN CODE - G.C. TO VERIFY PRIOR TO PURCHASE AND INSTAL. OF ANY FIXTURES. 26. EXTERIOR DECKS, BALCONIES, AND STAIRWAYS SEALED UNDERNEATH SHALL BE WATERPROOFED- ARCH. TO APPV. METHOD OF WATERPROOFING - G.C. TO SUBMIT SPECIFICATIONS. 27. SPECIAL INSPECTION IS REQUIRED FOR THE FOLLOWING: * FOUNDATION INSPECTION BY SOILS ENGINEER PRIOR TO CONCRETE POUR AND: * PER SOILS REPORT: OVER EXCAVATION, RECOMPACTION, FOOTING DEPTH, UTILITY TRENCH BACK FILL * RETAINING WALL BACK FILL, PRE SATURATION OF SLAB AREAS, EXTERIOR FLAT WORK AREAS. * ALL TO BE ADDRESSED IN A REPORT PRESENTED TO BUILDING DEPT. PRIOR TO FINAL * ALL FIELD WELDING OF STRUCTURAL STEEL * INSTALLATION OF ALL HIGH STRENGTH BOLTS * CERTIFICATION OF WELD, & BOLTING TO BE GIVEN TO BUILDING DEPARTMENT PRIOR TO FRAMING INSPECTION. 28. MAX. TEMP. OF 120° TO BE APPROVED BY THE USE OF PRESSURE BALANCE OR THERMOSTATIC MIXING VALVES TYP. @ SHOWERS & TUBS. 29. MAINTENANCE INFORMATION: THE BUILDER SHALL PROVIDE TO THE BUILDING OWNER AT OCCUPANCY MAINTENANCE INFORMATION FOR ALL FEATURES, MATERIALS, COMPONENTS, AND MANUFACTURED INFORMATION FOR ALL FEATURES, MATERIALS, COMPONENTS AND MANUFACTURED DEVICES THAT REQUIRE ROUTINE MAINTENANCE FOR EFFICIENT OPERATION. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY STATED AND INCORPORATED ON A READILY ACCESSIBLE LABEL. THE LABEL MAY BE LIMITED TO IDENTIFYING, BY TITLE AND/OR PUBLICATION NUMBER, THE OPERATION AND MAINTENANCE MANUAL FOR THAT PARTICULAR MODEL AND TYPE OF FEATURE, MATERIAL, COMPONENT, OR MANUFACTURED DEVICE. 30. AFTER INSTALLING WALL, CEILING, OR FLOOR INSULATION, THE INSTALLER SHALL MAKE AVAILABLE TO THE ENFORCEMENT AGENCY OR POST IN A CONSPICUOUS LOCATION IN THE BUILDING A CERTIFICATE SIGNED BY THE INSTALLER STATING THAT THE INSTALLATION IS CONSISTENT WITH THE PLANS AND SPECIFICATIONS FOR WHICH THE BUILDING PERMIT WAS ISSUED. THE CERTIFICATE SHALL ALSO STATE THE MANUFACTURER'S NAME AND MATERIAL IDENTIFICATION, THE INSTALLED R-VALUE, AND (IN APPLICATIONS OF LOOSE FILL INSULATION) THE MINIMUM INSTALLED WEIGHT PER SQUARE FOOT CONSISTENT WITH THE MANUFACTURER'S LABELED INSTALLED DESIGN DENSITY FOR THE DESIRED R- VALUE. 31. ON PROJECTS WITH EXCAVATIONS THAT WILL BE LOWER THAN ADJOINING PROPERTIES, 30 DAY NOTICE IS LEGALLY REQUIRED BY THE OWNERS & CONTRACTORS TO THE ADJOINING PROPERTY OWNERS OUTSIDE THE SETBACK AREA. 32. DISTANCE FROM THE FACE OF FOUNDATION TO PROPERTY LINE TO BE ZONING SETBACK PLUS WALL FINISH THICKNESS. 33. ROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR FIXTURES SHALL BE PROVIDED WITH ON EXHAUST FAN WITH A MINIMUM CAPACITY OF 50 CFM. DUCTLESS FANS ARE UNACCEPTABLE. CBC 1203.4.3.2.1, CMC T-4-4 34. SAFETY GLAZING SHALL BE PROVIDED AT THE FOLLOWING HAZARDOUS LOCATIONS: CBC 2406.3 A. SWINGING AND SLIDING DOORS B. WHEN LOCATED WITHIN 60- INCHES OF THE FLOOR SURFACE IN TUBS, SHOWERS, SAUNAS, OR STEAM ROOMS. C. WITHIN A 24-INCH ARC OF EITHER VERTICAL EDGE OF DOORS AND WITHIN 60-INCHES OF WALKING SURFACE. D. WHERE GLAZING AREA IS MORE THAN 9 SQ. FT. IN AREA, WITH A BOTTOM EDGE LESS THAN 18-INCHES ABOVE THE FLOOR AND TOP EDGE MORE THAN 36-INCHES ABOVE FLOOR. E. ADJACENT TO STAIRWAYS, LANDINGS AND RAMPS WITHIN 36-INCHES HORIZONTALLY OF WALKING SURFACE AND WITHIN 60-INCHES ABOVE WALKING SURFACE. F. ADJACENT TO STAIRWAYS WITHIN 60-INCHES HORIZONTALLY OF BOTTOM TREAD OF STAIRWAY AND EXPOSED SURFACE IS WITHIN 60-INCH ABOVE NOSE OF TREAD. 35. CLEARANCE FOR WATER CLOSET TO BE A MINIMUM OF 24-INCHES IN FRONT AND 15-INCHES FROM ITS CENTER TO ANY SIDE WALL OR OBSTRUCTION. CPC 407.5 36. THE NET AREA OF THE SHOWER ENCLOSURE SHALL BE 1,024 SQ. INCHES (7.1 SQ. FT.) OR MORE IN THE CLEAR FLOOR AREA, AND SHALL ALSO BE CAPABLE OF ENCOMPASSING A 30-INCH DIAMETER CIRCLE. CPC 411.7 37. WALL COVERINGS OR SHOWERS OR TUBS WITH SHOWERS SHALL BE OF CEMENT PLASTER, TILE, OR APPROVED EQUAL, TO A HEIGHT OF NOT LESS THAN 70-INCHES ABOVE DRAIN INLET. PROVIDE CEMENT BOARD OR CEMENT PLASTER BACKING FOR TILE. CBC 1210.3 38. MIN. 5/8" TYPE 'X' MOISTURE RESISTANT GYPSUM WALL BOARD IN ALL BATHROOMS AND KITCHENS 39. EXTERIOR LATH AND PLASTER: PROVIDE TWO LAYERS OF GRADE D PAPER OVER ALL WOOD BASE SHEATHING. CBC 2510.6 40. THE WATER HEATER BURNER TO BE AT LEAST 18-INCHES ABOVE THE GARAGE FLOOR, IF LOCATED IN A GARAGE. CPC 508.14 41. PROVIDE A 3-INCH DIAMETER BY 3-FOOT TALL STEEL PIPE EMBEDDED IN CONCRETE SLAB FOR PROTECTION OF WATER HEATERS IN GARAGE. CPC 508.14 42. WATER HEATERS TO BE STRAPPED AT TOP AND BOTTOM WITH 1-1/2" X 16 GAUGE STRAP WITH 3/8" DIA. X 3" LAG BOLT EACH IND. CPC 508.2 43. DRYER: THE CLOTHES DRYERS VENT SHALL NOT EXCEED 14-FEET IN OVERALL LENGTH. CMC 504.3.2 DRYER VENT TERMINATION MUST BE 3 FT. CLEAR FROM OPENINGS INTO THE BUILDING ( DOORS AND OPERABLE WINDOWS) . CMC 504.5 PROVIDE A MIN. 100 SQ.IN. OPENING IN THE DRYER DOOR. CMC. 504.3.2 44. SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS (R314.3): A. IN EACH SLEEPING ROOM. B. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS C. ON EVERY LEVEL OF DWELLING, INCLUDING BASEMENTS AND HABITABLE ATTICS. SMOKE ALARMS SHALL BE HARDWIRED WITH BATTERY BACK-UP AND INTERCONNECTED UNLESS EXEMPTED IN ACCORDANCE WITH SECTIONS R314.4 & R314.5 45. CARBON MONOXIDE ALARMS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS (R315.3): A. OUTSIDE OF EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOM(S) B. ON EVERY LEVEL OF THE DWELLING UNIT INCLUDING BASEMENTS. CARBON MONOXIDE ALARMS SHALL BE HARDWIRED WITH BATTERY BACK-UP AND INTERCONNECTED UNLESS EXEMPTED IN ACCORDANCE WITH SECTIONS R314.4 & R314.5 46. ALL RECEPTACLE OUTLETS IN BATHROOMS, ABOVE KITCHEN COUNTERTOP, CRAWL SPACES, GARAGE, ROOFTOPS, OUTDOOR OUTLETS, WITHIN 6-FEET OF WET BAR SINK/LAUNDRY SINK TO BE PROTECTED BY GROUND FAULT CIRCUIT INTERRUPTER (GFCI) CEC 210.8 47. ALL 120V SINGLE PHASE, 15 AND 20 AMP OUTLETS (RECEPTACLES, LIGHTING, SMOKE DETECTORS, ETC.) TO BE PROTECTED BY COMBINATION TYPE ARC-FAULT CIRCUIT INTERRUPTER (AFCI) CEC 210.12 48. ELECTRICAL SERVICE TO BE UNDERGROUND FOR NEW CONSTRUCTION OR ADDITIONS >50%. NBMC 12.32.015 49. INSPECTOR TO REVIEW AND APPROVE UNDERGROUND ELEC. SERVICE PRIOR TO CONCRETE PLACEMENT. 50. UTILITY COMPANY APPROVAL IS REQUIRED FOR METER LOCATION PRIOR TO INSTALLATION. 51. FACTORY-BUILT FIREPLACES, CHIMNEYS, AND ALL OTHER COMPONENTS SHALL BE LISTED AND LABELED AND SHALL BE INSTALLED IN ACCORDANCE WITH THE CONDITIONS OF THE LISTING 52. FIREPLACE: DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT THE TERMINATION OF FACTORY-BUILT CHIMNEY SYSTEMS AND ARE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS R1005.4NG. CMC (802.5.2.4) PROVIDE A PERMANENTLY ANCHORED GASEOUS FUEL BURNING PAN TO THE FIREBOX IN A SOLD FUEL BURNING FIREPLACE. SOLID FUEL BURNING FIREPLACE MUST COMPLY WITH THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES." GAS APPLIANCE FIREPLACE MUST COMPLY WITH THE CALGREEN CODE REQUIREMENTS." 53. ALL DOORS FROM THE HOUSE INTO THE POOL AREA SHALL BE EQUIPPED WITH AN APPROVED ALARM OR AN APPROVED ALTERNATE DROWNING PREVENTION SAFETY FEATURE. CBC 3109.4.4.2 54. GENERAL CONTRACTOR, CONTRACTORS, SUB-CONTRACTORS AND BUILDERS TO COORDINATE ALL ENGINEERING AND MECHANICAL DRAWINGS WITH ARCHITECTURAL DRAWINGS BEFORE PROCEEDING WITH WORK. IF DISCREPANCIES ARE APPARENTLY OBSERVED OR INFORMATION APPARENTLY IS THOUGHT TO BE MISSING, NOTIFY ARCHITECT WITHIN 24 HOURS WITH SKETCH, DRAWING, PDF, PHOTOCOPIES WITH LEGIBLE HAND WRITTEN NOTES AND/OR WRITING (FAX, EMAIL OR CORRESPONDENCE). IF CONFLICT WITH EXISTING CONDITIONS, PROVIDE DOCUMENTATION (PHOTOS, SKETCHES, DWGS) OF EXISTING CONDITIONS AND SUGGEST PROPOSAL(S) FOR SOLUTION (SKETCH, DRAWING, AND/OR WRITING). IN CASE OF ANY DISCREPANCIES, THE ARCHITECT IS THE SOLE INTERPRETER OF THE CONTRACT DOCUMENTS. 55. ISSUANCE OF A BUILDING PERMIT DOES NOT RELIEVE APPLICANTS OF THE LEGAL REQUIREMENTS TO OBSERVE COVENANTS, CONDITIONS AND RESTRICTIONS WHICH MAY BE RECORDED AGAINST THE PROPERTY OR TO OBTAIN PLANS. YOU SHOULD CONTACT YOUR COMMUNITY ASSOCIATIONS PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION AUTHORIZED BY THIS PERMIT. 56. LAND. WALLS LOCATED IN FRONT AND BACK OF PROPERTY SHALL NOT EXCEED 42" HT. REFER. LAND. DWGS FOR LOC'T. 57. LAND. WALLS LOCATED BTW. NEIGHBORS SHALL BE SHARED ON PROP. LINE. REFER. LAND. DWGS AND SEE ATTACHED DOCUMENT FOR "AGREEMENT TO BUILD A FENCE OR WALL CENTERED OVER THE PROPERTY WALL." 58. ALL INTERIOR AND EXTERIOR JOINTS BETWEEN DIFFERENT MATERIALS OR FINISHES SHALL RECEIVE A BEAD OF CAULKING OR SEALANT TO FORM A REVEAL TO MATCH COLOR OF ADJACENT SURFACE. COORDINATE COLORS WITH ARCHITECT. 59. CONTRACTOR SHALL NOTIFY ARCHITECT FOR CLARIFICATION PRIOR TO BIDDING OF ANY DISCREPANCIES BETWEEN ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS. BID SHALL BE BASED ON THE MOST STRINGENT REQUIREMENT. 60. CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT OF ANY UNEXPECTED OR UNKNOWN FIELD CONDITIONS, ERRORS, OMISSIONS, OR DISCREPANCIES IN THE DRAWINGS, PROJECT MANUAL, OR CONTRACT DOCUMENTS PRIOR TO PROCEEDING WITH THE WORK OR SHOP FABRICATIONS. HEATING VENTILATING/AIR COND. DRINKING FOUNTAIN/DOUGLASS FIRD.F. EA. E.P. ENCL. EMER. ELEV. ELEC. EL. E.J.E. DWG. D.S.P. D.S. DR. DN. DIM. DIAG. DIA. EACH EXPANSION JOINT ELEVATION ELEVATOR EMERGENCY ENCLOSURE ELECTRIC PANEL ELECTRIC DIAMETER DIAGONAL DIMENSION DOWN SPOUT DRY STAND PIPE EAST, ENTRY DOWN DOOR DRAWING DET. DEPT. DBL. CTR. CTSK. CORR. CONT. CONST. COND. CONC. CNTR. CLR. CLKG. CLG. C.J. C.I. CHG. CHAN. C.G. CEM. C.B. CAB. CONCRETE CONDITION CONSTRUCTION CONTRACTOR/ CONTINUOUS CORRIDOR, CORROSIVE COUNTERSUNK DEPARTMENT COUNTER CENTER DOUBLE DETAIL CATCH BASIN CORNER GUARD CAST IRON CONTROL JOINT/ CONST. JOINT CAULKING CABINET CEMENT CHANNEL CHANGE CEILING CLEAR LOAD FROM ABOVE JANITOR KITCHEN LANDSCAPED AREA LABORATORY LAMINATE LAVATORY POUNDS LEFT HAND LOCKER LUMINOUS MAINTENANCE MASONRY LBS. LFA MAS. MAINT. LUM. LT. LKR. L.H. LIGHT LAV. LAM. LAB. L.A. L. KIT. JST. JT. JAN. JOINT JOIST LOW/LINEN HOSE BIB HOLLOW CORE HARDWOOD HARDWARE HEIGHT HOLLOW METAL GALVANIZED IRON GLU-LAM BEAM GROUND GYPSUM HORIZONTAL INSULATION INTERIOR INVERT/INVERTED INSIDE DIAMETER/INTERIOR DESIGNER HDWR. I.D. HVAC INV. INT. INSUL. IN. HR. HORIZ. H.M. HT./HGT. HOUR INCH GYP. GR. GND. G.L.B. GL. G.I. HDWD. HD. H.C. H.B. H.HIGH HARD GLASS GRADE AREA DRAINA.D. B.W. BR. B. BOT. BM. BLK'G. BLK. BLDG. BITUM. BET. BD. AUTO. ASSY. ASB. ARCH. APPX. A.P. ANOD. ALT. AL. ADJ. ADH. BITUMINOUS BLOCKING BATH BEDROOM BACK OF WALK, BOT. OF WALL BOARD BETWEEN BUILDING BLOCK BEAM BOTTOM ADHESIVE ADJUSTABLE ALUMINUM ALTERNATE ANODIZED ACCESS PANEL APPROXIMATELY ARCHITECTURAL ASBESTOS ASSEMBLY AUTOMATIC PL LC ACOUS. A.C. A/C A.B. # ∅ @ & ANGLE CENTERLINE DIAMETER OR ROUND PERPENDICULAR POUND OR NUMBER PROPERTY LINE, PLATE ANCHOR BOLT AIR CONDITIONING ASPHALT CONCRETE ACOUSTICAL AT AND FINISH GRADE FLAT HEAD FIXTURE FLOW LINE FLASHING FLUORESCENT FACE OF CONCRETE/FACE OF CURB FACE OF FINISH FACE OF STUD/FACE OF STRUCTURE FACE OF MASONRY FIREPLACE FLOOR SINK FOOT OR FEET FOOTING FURRING FUTURE GALVANIZED GRAB BAR/GRADE BEAM GENERAL GROUND FAULT INTERRUPTG.F.I. GEN. G.B. GALV. GA. FUT. FURR. FTG. FT. F.S. FP. GAUGE F.O.M. F.O.S. F.O.F. F.O.C. FLUOR. FLR. FLASH. F.L. FIX./FIXT. FIN. F.H. F.G. FINISH FLOOR EQUIPMENT EXISTING EXHAUST EXPOSED EXTERIOR FIRE ALARM FLOOR CLEAN OUT FLOOR DRAIN FOUNDATION FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET EQPT./EQPM. F.E.C. F.E. FDN. F.D. F.C.O. F.A. F. EXT. EXPO. EXH. EXST. FIXED SOUTHS. SUPPLY AIR SOLID CORE SCHEDULE SECTION SHELF SHEET SHEATHING SIMILAR SOFFIT JOIST SERVICE SINK STATION STANDARD STEEL STORAGE STRUCTURAL SUSPENDED SYMMETRICAL STAINLESS STEEL SEAT COVER DISPENSER SUB DRAIN/SOAP DISPENSER S.S. SUSP. STRUCT. STOR. SYM. STL. STD. STA. S.SK. S.C.D. SHT'G. SCHED. S.D. S.J. SIM. SHT. SH. SEC. S.C. S.A. PLUMBING PLYWOOD POINT OF CONNECTION PROJECTION POINT RETURN AIR RADIUS ROOF DRAIN RECEPTACLE RECTANGULAR REFERENCE REFRIGERATOR ROOF DRAIN LEADER REGISTER REQUIRED RESILIENT' ROOM REDWOOD REINFORCEMENT ROUGH OPENING RETAIN(ING), RETURN RECT. REINF. RESIL. REQ'D. REFR./ R/F. RET. R.O. RWD. RM. REG. REF. R.D.L. RECPT. PROJ. PLYWD. PLUMB. R.D. RAD. R.A. PT. PR. PNT. PAIR MOUNTEDMTD. MULLION NORTH NATURAL NUMBER NOMINAL NOT TO SCALE OVER OVERALL OBSCURE OFFICE OPENING OPPOSITE PERIMETER PLATE/PROPERTY LINE PLASTER NOT IN CONTRACT NATURAL GRADE OVERFLOW DRAIN PLASTIC LAMINATE OUTSIDE DIAMETER (DIMENSION) O/. P.LAM. O.F.D. PERIM. OPNG. O.D. PLAS. PL. OPP. OFF. OBS. O.A. N.G. N.I.C. N.T.S. NOM. NO. NAT. N. MUL. MATERIAL MAXIMUM MECHANICAL MEMBRANE METAL MAN HOLE MINIMUM MIRROR MOSAIC MEDICINE CABINET MANUFACTURER MISCELLANEOUS MASONRY OPENING MAX. MEMB. MECH. M.O. MISC. MFR./MFGR. M.C. MOS. MIR. MIN. M.H. MET./MTL. MAT. TYPICALTYP. UNIFORM BULIDING CODE UNDERWRITER'S LABORATORY UNLESS NOTED OTHERWISE VENT THROUGH ROOF WEST, WIDE, WIDTH V.T.R. WP. W.I. W.C. W.H. W. WD. W/.WITH WOOD WATER HEATER WATER CLOSET WROUGHT IRON WATERPROOF U.N.O. U.L. U.B.C. VERT. VENT. UR. UNF. U.UNDER UNFINISHED URINAL VENTILATING VERTICAL TOP OF PAVING TOP OF STRUCTURE/SLAB TONGUE AND GROOVE TOP OF CURBT.C. T.&G. T.W. T.O.S. T.PL. T.P. TER. TEMP. TEL. T.CL. TRANS. THK.THICK TRANSFORMER TIME CLOCK TELEPHONE TEMPERED TERRAZZO TOP OF PLATE TOP OF WALL T.TREAD PAINT(ED) P.O.C. EQ.EQUAL / EQUIVALENT FIELD VERIFYF.V. (E.)EXISTING NEW(N.) VER.VERIFY FACTORYFAC. B.O.BY OWNER/BY OTHERS GENERAL CONTRACTORG.C. APPV'D.APPROVED BEL.BELOW ON CENTERO.C. ABV.ABOVE HDR.HEADER SELECTEDSEL. METAL BOLTM.B. PARALLEL STRAND LAMINATEPSL. ROOF RAFTERR.R. /CEILING JOIST FLOOR JOISTF.J. SIMPSONSIMP. T.S.TOP OF STEP UNDERGROUNDU.G. V.VERTICAL W.W.M.WELDED WIRE MESH EACH WAYE.W. DECO.DECORATIVE EXISTING GRADEE.G. GRADE PLANEG.P. 61. CONTRACTOR SHALL PREPARE AND MAINTAIN ALL CONSTRUCTION, AND SURROUNDING AREAS, FREE OF DEBRIS OR HAZARDOUS MATERIALS AT ALL TIMES. CONTRACTOR SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT DUST FROM RISING. 62. CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR AND/OR THE REPLACEMENT OF ANY ITEMS DAMAGED DURING CONSTRUCTION OR CLEAN-UP. ANY DAMAGE TO EXISTING STRUCTURES DURING THE CONSTRUCTION OR THE NEW WORK SHALL BE REPAIRED TO EQUIVALENT OR BETTER THAN ORIGINAL CONDITION AT CONTRACTOR'S EXPENSE. 63. CONSTRUCTION PERSONNEL SHALL BE CONFINED TO THE LIMITS OF THE CONSTRUCTION AREA. ALL OSHA REGULATIONS FOR CONSTRUCTION AREAS SHALL BE STRICTLY FOLLOWED. CONTRACTOR SHALL PROVIDE PROPER SAFEGUARDS DURING ALL PHASES OF CONSTRUCTION. 64. CONTRACTOR TO REMOVE, RELOCATE OR RE-ROUTE, AS NECESSARY, ELECTRICAL, TELEPHONE, WATER, SEWER, GAS OR ANY OTHER UTILITY LINES ENCOUNTERED AND SHALL COORDINATE THIS WORK WILL ALL LOCAL UTILITY COMPANIES. 65. CONTRACTOR SHALL PROVIDE TEMPORARY WEATHER PROTECTION FOR PORTIONS OF THE WORK THAT BECOME EXPOSED TO WEATHER AND SHALL BE RESPONSIBLE FOR DAMAGE CAUSED BY INSUFFICIENT PROTECTION. 66. CONTRACTOR TO OBTAIN WRITTEN APPROVAL FROM OWNER AND ARCHITECT PRIOR TO ANY CHANGES OR DEVIATION FROM CONTRACT DOCUMENTS. 67. CONTRACTOR SHALL SUBMIT IN WRITING ALL PROPOSALS FOR ADDITIONAL WORK TO THE OWNER FOR REVIEW AND APPROVAL. NO WORK IS TO PROCEED UNTIL AN AUTHORIZATION TO PROCEED, SIGNED BY THE ARCHITECT & OWNER'S REPRESENTATIVE IS RETURNED TO THE GENERAL CONTRACTOR. 68. CONTRACTOR SHALL BE AWARE THAT SPECIFIC FIRE-RATED SEPARATION WITHIN THE BUILDING'S CONSTRUCTION ARE REQUIRED BY CODE. THE USE OF SPECIFIC MATERIALS AND COMBINATION OF MATERIALS WITHIN FIRE RATED ASSEMBLIES, AS CALLED FOR ON THE DRAWINGS AND SPECIFICATIONS, ARE FOR THE PURPOSE OF ACHIEVING THOSE REQUIRED FIRE SEPARATIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THAT ANY CHANGE IN MATERIAL THAT IS REQUESTED BY OR MADE BY THE CONTRACTOR AND/OR IT'S SUBCONTRACTORS, FROM THOSE MATERIALS DRAWN OR SPECIFIED, DOES NOT IN ANY WAY AFFECT OR LESSEN THE REQUIRED CONSTRUCTION ASSEMBLY. SPECIFIC SEQUENCES OR METHODS OF ACHIEVING FIRE RATED ASSEMBLIES REQUIRED BY A "U.L. NO." LISTING SHALL BE FOLLOWED WITHOUT DEVIATION, UNLESS OTHERWISE NOTED OR DETAILED. 69. CONTRACTOR TO FURNISH AND INSTALL ALL BLOCKING REQUIRED FOR WALL MOUNTED OR BRACED FIXTURES, MILLWORK, SHELVES, TOILET FIXTURES, AND ACCESSORIES OR 'BY OTHER' ITEMS DESCRIBED IN INTERIOR DESIGN AND ARCHITECTURAL DRAWINGS. BLOCKING SHALL BE CONSTRUCTED TO SUPPORT THE IMPOSED LOAD. 70. ALL MANUFACTURED ARTICLES, MATERIALS AND EQUIPMENT SHALL BE SUPPLIED, INSTALLED, CONNECTED, ERECTED, USED, CLEANED AND CONDITIONED AS DIRECTED BY THE MANUFACTURERS. 71. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY/COORDINATE UTILITY REQUIREMENTS FOR ALL OWNER/VENDOR FURNISHED EQUIPMENT, FIXTURES OR APPLIANCES. 72. CONTRACTOR SHALL PROVIDE ALL NECESSARY FASTENERS, SUPPORTS, SHIMMING, FLASH PATCHING, ETC. FOR THE PROPER INSTALLATION OF SUCH ITEMS AS DIRECTED BY THE MANUFACTURERS. 73. UPON COMPLETION OF THE PROJECT, THE CONTRACTOR SHALL GIVE TO THE OWNER A COMPLETE SET OF AS-BUILT CIVIL, LANDSCAPE, ARCHITECTURAL, MECHANICAL, PLUMBING ELECTRICAL AND FIRE PROTECTION DRAWINGS ALONG WITH THE WRITTEN GUARANTIES, OPERATION AND MAINTENANCE MANUALS OF ALL EQUIPMENT AND FINISHES INSTALLED. THE CONTRACTOR SHALL MAINTAIN A CURRENT SET OF AS-BUILT DRAWINGS AND SPECIFICATIONS. INFORMATION SHALL BE RECORDED BY CONTRACTOR AS CONSTRUCTION PROGRESSES AND REVIEWED FOR COMPLETENESS AT EACH REQUISITION REQUEST. 74. CONTRACTOR IS RESPONSIBLE TO THOROUGHLY VACUUM CLEAN ALL CARPETED ARES, CLEAN ALL FLOORING, MILLWORK, LIGHT FIXTURES, GLASS, ETC. AND UNCOVER AND VACUUM OUT ALL MECHANICAL UNITES AFTER THE WORK IS COMPLETED AND MAINTAIN CLEAN CONDITIONS THROUGH THE TENANT'S MOVE-IN. GENERAL NOTES CONTINUED PARCEL MAP 3 NO. REVISION DATE 34 JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONSOWNER INFORMATION:PROJECT NAME STATUS These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT T-1.2 03/22/2019 2018-30SUPPLEMENTAL NOTES &DOCUMENTSBAY FRONT TRADITIONAL BAY FRONTTRADITIONALSOUTH BAYFRONTWATERPOINTE, LLC.610 NEWPORT CENTERDRIVE, SUITE 890,NEWPORT BEACH, CA92660CDP -FIRST CHECK 400 S BAY FRONTNEWPORT BEACH, CA 92662CAITLIN SMITH CAL GREEN -RESIDENTIAL MANDATORY MEASURES RESIDENTIAL CONSTRUCTION MINIMUM REQUIREMENTS 2 1 3 NO. REVISION DATE 35 11/5/2018 36 DW T UP UP UP UP UPUP UP UP 464 SF GARAGE 1029 SF FIRST FLOOR 16' - 8 1/2"15' - 2"10' - 11 3/4"6' - 1 3/8"18' - 5 1/8"1' - 9 1/2" 1' - 3 1/2" 1' - 9 1/2" 7 3/4"11 1/4"1' - 0 1/2"9' - 0"1' - 0 1/2"1' - 2"16' - 8 1/2"15' - 2"10' - 11 3/4"2' - 9" 8 1/4" 2' - 8 1/8" 16' - 0 3/8"2' - 7 5/8"17' - 0"2' - 8 1/8"23' - 9 1/4"18' - 11 3/8"13' - 0"9' - 11 3/4"22' - 2 1/4"12' - 2 1/2"7 3/4" A B C D E F G H I J K L M N 118 SF L1 61 SF L2 62 SF L3 53 SF ENTRY 214 SF PATIO O P 7' - 9"4' - 5 1/2"8' - 9 7/8"24' - 0 3/8"1 2 1421 SF SECOND FLOOR 3' - 9" 8 3/8"16' - 0 1/8"13' - 4 1/2"6' - 10 3/4"8' - 1 1/2"22' - 11 1/4"1' - 11 3/4" 3' - 1 3/4" 8 3/8"16' - 0 1/8"15' - 2"10' - 11 3/4"2' - 3" 10' - 9 1/4"9' - 6"1/2"22' - 3 1/4"1' - 8 5/8"22' - 3 1/4"22' - 8 1/4"1' - 1"4' - 2 7/8"5' - 1 7/8"5' - 1 1/2"5 3/8"14' - 11 5/8"1' - 0 1/8"12' - 7 5/8"23' - 8 3/8"22' - 11 1/4"1' - 11 3/4" 264 SF M. BALCONY A B C D E F G H I J K L M 5' - 0" 4' - 3 7/8"8' - 9 7/8"24' - 0 3/8"8' - 2"1 2 275 SF THIRD FLOOR 5' - 1 1/8"10' - 9 1/4"7' - 8 3/8"18' - 9 1/2"5' - 6 7/8"5' - 6"6' - 1 1/2"7' - 10" 459 SF VIEW DECK 198 SF ROOF DECKA C B D JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONSOWNER INFORMATION:PROJECT NAME STATUS These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT A-0.1 05/01/2019 2018-30BUILDING AREA PLANSBAY FRONT TRADITIONAL BAY FRONTTRADITIONALSOUTH BAYFRONTWATERPOINTE, LLC.610 NEWPORT CENTERDRIVE, SUITE 890,NEWPORT BEACH, CA92660FIRST CHECK 400 S BAY FRONTNEWPORT BEACH, CA 92662CAITLIN SMITH 1/8" = 1'-0"1 FIRST FLOOR (T.O.S.) 1/8" = 1'-0"2 MASTER FLOOR T.O.S. (TYP.) 1/8" = 1'-0"3 THIRD FLOOR T.O.S. BUILDING AREA SCHEDULE Name AREA COMMENTS FIRST FLOOR 1029 SF SECOND FLOOR 1421 SF THIRD FLOOR 275 SF 2724 SF GARAGE 464 SF 464 SF GRAND TOTAL 3188 SF OUTDOOR AREA SCHEDULE NAME AREA COMMENTS ENTRY 53 SF COVERED VIEW DECK 459 SF ROOF DECK 198 SF 710 SF PATIO 214 SF PARTIALLY COVERED M. BALCONY 264 SF COVERED 478 SF GRAND TOTAL 1188 SF LOT INFORMATION: FIRST FLOOR PLAN A B C D E 16' -8 1/2" X 2' -7 5/8" = 44.03 16' -0 3/8" X 17' -0" = 272.53 16' -8 1/2" X 2' -7 5/8" = 44.03 15' -2" X 23' -9 1/4" = 360.52 F 10' -11 3/4" X 18' -11 3/8" = 208.03 6' -1 3/8" X 9' -11 3/4" = 61.01 TOTAL: 1,029 SF ZONED: R-BI SITE AREA:2630 S.F. BUILDABLE AREA: 1992 S.F. TOTAL ALLOWABLE AREA: 1.5 x 1992 S.F. = 2988 S.F. +200 S.F. = 3188 S.F. REQ'D OPEN VOLUME = 1992 S.F. X .15 = 298.8 S.F. (7'-6" HT MIN.) OPEN VOLUME PROVIDED = 478 > 298.8 S.F. G H 2' -9" X 13' -0" = 35.75 0' -8 1/4" X 4' -5 1/2" = 3.06 GARAGE FLOOR PLAN I J K L M 18' -5 1/8" X 22' -2 1/4" = 408.85 1' -9 1/2" X 1' -0 1/2" = 1.86 1' -3 5/8" X 9' -0" = 11.71 1' -9 1/2" X 1' -0 1/2" = 1.86 N 0' -7 3/4" X 0' -11 1/4" = .60 0' -7 3/4" X 1' -2" = .75 TOTAL: 464 SF O P 2' -8 1/8" X 12' -2 1/2" = .32.68 0' -8 1/4" X 7' -9" = 5.32 SECOND FLOOR PLAN A 0' -8 3/8" X 2' -7 5/8" = 1.83 B 0' -8 3/8" X 2' -7 5/8" = 1.83 C 16' -0 1/8" X 22' -3 1/4" = 356.56 D 11' -4 3/4" X 22' -8 1/4" = 258.54 E 15' -2" X 1' -1" = 16.43 F 8' -10 1/2" X 4' -2 7/8" = 37.62 G 4' -4 1/2" X 5' -1 5/8" = 22.46 H 8' -10 1/2" X 5' -1 1/2" = 45.48 I 3' -1 3/4" X 0' -5 3/8" = 1.40 J 8' -1 1/2" X 14' -11 5/8" = 121.62 K 2' -3" X 1' -0 1/8" = 2.27 L 22' -11 1/4" X 23' -8 3/8" = 543.57 M 1' -11 3/4" X 12' -7 5/8" = 25.00 TOTAL: 1,435 SF THIRD FLOOR PLAN A 5' -1 1/8" X 6' -1 1/2" = 31.19 B 10' -9 1/4" X 5' -6 7/8" = 60.02 C 7' -10" X 5' -6" = 43.08 D 7' -8 3/8" X 18' -9 1/2" = 144.65 TOTAL: 279 SF NO. REVISION DATE OPEN AREA CALCS 1 2 24' -0 3/8" X 8' -9 1/8" = 210.25 24' -0 3/8" X 4' -3 7/8" = 103.75'/2= 51.88' TOTAL: 262.13 SF OPEN AREA CALCS 1 2 24' -0 3/8" X 8' -9 7/8" = 211.94 24' -0 3/8" X 4' -3 7/8" = 103.81'/2= 51.90' TOTAL: 263.84 SF OUTDOOR CALS VIEW DECK 457 ROOF DECK 195 TOTAL: 652 SF 37 UP UP UP UP UP EXISTING BUILDING GP & SIGN 6' TALL WDF PLANTER PLANTERPLANTER PROPERTY LINE PROPERTY LINEBULKHEAD SAND PLANTERSTAIRS WV 6' TALL WDF FOUND MONUMENT LOTS 1 & 2 SECTION 1 BALBOA ISLAND BLOCK 7 M.M. 3/42 SOUTHBAY FRONT(5.98) FS (6.08)FS (6.09)FS (6.12)FS (6.15) FS (7.42)FS(7.41) FS (7.43) FF (7.38) FS (7.40) (7.25) FS (7.42)FF (7.24) NG (7.06) NG (6.87) NG (6.34) AC (6.41) AC (6.78)NG (7.20)TW (6.17)FS (7.27)TW (6.13)FS (6.16)FS (6.03) FS (6.06)FS (7.25)TS (6.31)AC(6.48) AC (6.10)FS (7.31) FS (7.38) FS (5.71) (7.41)FS (6.29) GP FS (6.23) FS (5.89) FL (5.68) FL(6.06) GM (6.54) AC (7.43)TS (6.94) FS(8.96) TBH (8.96) TBH (8.97) TBH (7.02)FC (5.90)FS (7.02)FC (5.77)FS (7.04)FC (5.80)FS (6.23) FS (6.15)FS (6.07)TC (5.81)FS(7.10) TS (32.83) CHIMNEY TOP N35°58'27"E 86.30'N43°49'20"W 61.02'N43°50'00"W 61.05'UP UP DW T UP UP UP R.Y.S.B. 5' - 0"S.Y.S.B.3' - 0"S.Y.S.B.3' - 0"PEARL AVENUE S. BAY FRONT ALLEY2' - 6" N36°51'17"E 86.30' N36°52'30"E 86.30'N43°49'20"E30.49'N43°49'20"E30.52'C.L. TO P.L.20' - 0"C.L. TO P.L. 7' - 6" 9.00' T.O.S. 9.00' T.O.S. GREAT ROOM LOUNGE KITCHEN DINING ELEV.FOYER STAIRS 2- CAR GARAGE POWDER ENTRY 2 21 1 F.O.F.3' - 10 1/8"4' - 0 1/8"F.O.F.3' - 2 1/8"3' - 2 5/8"F.O.F.4' - 8 1/8"4' - 8 5/8"F.O.F.2' - 2 7/8"2' - 4 7/8"F.O.F.4' - 8 1/8"4' - 8 5/8"F.O.F.3' - 0"3' - 0 1/2"F.O.F.3' - 0"3' - 0 1/2"F.O.F.3' - 9 1/2"3' - 10"F.O.F. 4' - 6 1/2" 4' - 7" F.O.F. 3' - 3 1/4" 3' - 5 1/4" 5' - 4 3/4"8' - 0 1/2"F.O.F.8' - 0"1 1 1 1 1 1 2 2 33 3 3 1' - 7 7/8" F.O.F. 1' - 7 3/8"F.O.F.4' - 4 1/8"4' - 4 5/8"8' - 3 5/8" F.O.F. 8' - 3 1/8" 8' - 3 5/8" F.O.F. 8' - 3 1/8"F.O.F.6' - 0 1/4"6' - 0 3/4"5' - 4 1/2" SLOPE PER CIVIL3' - 0 1/2"F.O.F.3' - 0"4 5 6 7 7 88 8 9 9 10 10 11 1212 12 12 1314 15 16 16 16 17 17 17 18 18 18 18 1818 18 18 18 19 CLR.21' - 2 1/4"CLR. 19' - 8" CLR. 21' - 0" 12.94' T.W.12.94' T.W. 8.00' T.O.W. 8.00' T.O.W. 10.00' T.O.R. 10.71' T.O.P. 10.71' T.O.P.10.00' T.O.R. 10.71' T.O.P. 20 21 21 22 CLR.3' - 0"CLR. 3' - 0" 232323 23 23 24 25 26 PLANTERPLANTERL L L L L LL L LL L L L L L LL L L L L LLLL L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L NEARBY 6.94 FSNEARBY 6.94 FSNEARBY 7.38 FSNEARBY 7.31 FS NEARBY 6.03 FS NEARBY 6.87 FS NEARBY 6.87 FS NEARBY 6.17 FS NEARBY 6.17 FS NEARBY 6.15 FS NOTE; ENCROACHMENT PERMIT AGREEMENT IS REQ'D. FOR ANY WORK PROPOSED IN THE PUBLIC R.O.W. ALL NON-STANDARD IMPROVEMENTS SHALL COMPY WITH CIY COUNCIL POLICY L-6. NOTE; ENCROACHMENT PERMIT AGREEMENT IS REQ'D. FOR ANY WORK PROPOSED IN THE PUBLIC R.O.W. ALL NON-STANDARD IMPROVEMENTS SHALL COMPY WITH CIY COUNCIL POLICY L-6. 26 26 NEARBY 6.87 FS S. BAY FRONT27 SLOPE PER CIVIL 28 13.00' T.W.13.00' T.W. 8.92' T.O.W. 29 29 29 21 20 18 8.92' T.O.W. 30 30 30 TRASH AREA 31 32 32 32 32 33 3434 35 35 PATIO 36 36 37 3839 38 39 39 C.C. 38 40 6.87' 6.15 6.317.31 LAVANDULA SPP. LAVENDER (LOW WATER USE) PLANT LEGEND L JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONSOWNER INFORMATION:PROJECT NAME STATUS These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT A-0.0 03/22/2019 2018-30ARCHITECTURAL SITE PLANBAY FRONT TRADITIONAL BAY FRONTTRADITIONALSOUTH BAYFRONTWATERPOINTE, LLC.610 NEWPORT CENTERDRIVE, SUITE 890,NEWPORT BEACH, CA92660CDP -FIRST CHECK 400 S BAY FRONTNEWPORT BEACH, CA 92662CAITLIN SMITH JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONSOWNER INFORMATION:PROJECT NAME STATUS These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT A-0.0 03/22/2019 2018-30ARCHITECTURAL SITE PLANBAY FRONT TRADITIONAL BAY FRONTTRADITIONALSOUTH BAYFRONTWATERPOINTE, LLC.610 NEWPORT CENTERDRIVE, SUITE 890,NEWPORT BEACH, CA92660CDP -FIRST CHECK 400 S BAY FRONTNEWPORT BEACH, CA 92662CAITLIN SMITH KEYNOTE LEGEND 1 PROPERTY LINE 2 REAR YARD SETBACK 3 SIDE YARD SETBACK 4 (E.) WATER VALVE (REF. SURVEY & CIVIL DWGS.) 5 (E.) GAS METER(S) - REF. CIVIL DWGS. 6 STREET SIGN - PROTECT IN PLACE 7 CENTERLINE OF ALLEY 8 CENTERLINE OF STREET 9 (E.) STREET TREE TO REMAIN - PROTECT IN PLACE 10 TRASH BIN - PROTECT IN PLACE 11 (E.) STORM DRAIN VAULT - (REF. CIVIL DWGS.) 12 CURB 13 (E.) PLANTER - TO BE REMOVED 14 (E.) STAIR TO REMOVE 15 (E.) SEWER M.H. (REF. SURVEY & CIVIL DWGS.) 16 (E.) BULK HEAD 17 (E.) WALL TO BE REMOVED 18 OUTLINE OF EXISTING BUILDING - TO BE DEMOLISHED 19 (E.) STREET LIGHT PULL BOX, PROTECT IN PLACE 20 INTERIOR STAIRS/STEPS - REF. PLANS 21 CONCRETE STEPS ON GRADE - REF. CIVIL DWGS. 22 MAIN SERVICE PANEL, 400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION) - VERIFY LOC'N. W/. SO. CA. EDISON 23 (E.) SIDEWALK - NOT A PART 24 VEHICLE - MINIMUM PARKING DIMENSIONS ON PLANS 25 HARDSCAPE - COLORED & SCORED CONCRETE (AS SELECTED) PER. LAND. DESIGNER 26 HARDSCAPE - STONE PAVERS (AS SELECTED) PER. LAND. DESIGNER 27 (N.) DRIVEWAY APPROACH & CURB CUT, STANDARD CONC. PER CNB STANDARDS - REF. CIVIL DWGS. 28 (N.) GATE - PER LANDSCAPE DESIGNER (MAX. 5' - 6" HT. ABOVE NATURAL GRADE) 29 PROPERTY LINE FENCE (NEW) O. 6" CURB FOUNDATION, WOOD TO MATCH - (MAX. 6' ABV. N.G.) 30 GUTTER 31 TRASH LOCATION - SCREEN FROM STREET AS NEEDED 32 (N.) LANDSCAPE WALL (MAX. 42 ABV. N.G.) - FINISH TO MATCH AS SEL. 33 CURB - TO BE REMOVE 34 A/C. CONDENSER UNIT - SIZE TBD - PROVIDE POWER AND SOUND DAMPENING PAD AS REQ'D. (SOUND ATT. REQ'D. BY C.N.B.) SEP. PERMIT REQ'D, REF. 7/T-1 DEF. SUBMT'L. #2 35 (E.) GUARD POST TO BE REMOVED 36 EXTERIOR GLASS GUARD - 34" - 38" ABV. NOSING (36" TYP. U.N.O.), REF. DTL. 4 & 13/AD-1 37 EXTERIOR COMBUSTION AIR DUCTS SHALL BE LISTED COMPONENTS OF THE FIREPLACE, AND INSTALLED ACCORDING TO THE F.P. MFGR'S. INSTR'S. (CRC R1005) 38 DRAIN LINE - IN WALL/FROM ABV., TO BE METAL VERIFY W/. G.C. (REF. CIVIL DWGS. & DTLS.) 39 OVERFLOW DRAIN LINE - IN WALL/ FROM ABV., TO BE METAL VERIFY W/. G.C. (REF. CIVIL DWGS. & DTLS.) 40 FIREPLACE - PREFABRICATED, GAS ONLY - MASON-LITE FIREPLACE, MODEL 'BURNTECH GBVS49' ICC# ESR-2401 [DTL. 22/AD-1] (FACTORY BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR COMPONENTS SHALL BE LISTED AN INSTALLED IN ACCORDANCE W/. THEIR LISTING AND MFG'R. INSTALLATION INSTRUCTIONS. GASEOUS FUEL BURNING PAN MUST BE PERMANENTLY ANCHORED TO THE FIREBOX. FIREPLACE MUST COMPLY W/. THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES.) TRUE NORTH DIMENSION NOTE: ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE NEAREST 1/8" -CONTACT ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS. 1/4" = 1'-0"1 ARCHITECTURAL SITE PLAN PROJECT NORTH LANDSCAPE NOTES: 1. ENCOARCHMENT PERMIT REQ'D. FOR ANY WORK PROPOSED IN THE PUBLIC R.O.W. 2. IF APPLICABLE, REF. PRELIMINARY LANSCAPE PLAN, FOR ALL HARDSCAPE & PLANTING AREAS WITH REPECTIVE HEIGHTS AND MATERIALS. GENERAL NOTE: SEE SHEET A-3 FOR ROOF PLAN INFORMATION NOT SHOWN ON THIS SHEET (INCLUDING EAVE DETAILS AND PROJECTION DISTANCES). C.N.B. NOTES: 1. ISSUANCE OF A BUILDING PERMIT BY THE CITY OF NEWPORT BEACH DOES NOT RELIEVE APPLICANTS OF THE LEGAL REQUIREMENTS TO OBSERVE COVENANTS, CONDITIONS AND RESTRICTIONS WHICH MAY BE RECORDED AGAINST THE PROPERTY OR TO OBTAIN PLANS YOU SHOULD CONTACT YOUR COMMUNITY ASSOCIATIONS PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION AUTHORIZED BY THIS PERMIT. 2. PRIOR TO PERFORMING ANY WORK IN THE CITY RIGHT-OF-WAY AN ENCROACHMENT PERMIT MUST BE OBTAINED FROM THE PUBLIC WORKS DEPARTMENT. 3. A CAL-OSHA PERMIT IS REQUIRED FOR EXCAVATIONS DEEPER THAN 5' AND FOR SHORING AND UNDERPINNING. 1/8" = 1'-0"2 GRADE PLANE EXHIBIT NOTES: 1. THE CONTRACTOR SHALL PROVIDE ALL LABOR, TRANSPORTATION, MATERIALS, AND SERVICES NECESSARY TO FURNISH AND INSTALL ALL CONSTRUCTION ELEMENTS AS SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. 2. ALL WORK SHALL BE PERFORMED BY A CALIFORNIA LICENSED CONTRACTOR. 3. CONSTRUCTION AND INSTALLATION OF ALL LANDSCAPE ITEMS SHALL BE ACCORDING TO STATE, COUNTY AND LOCAL CODES, ORDINANCES AND UP TO CAL- OSHA SAFETY ORDERS REGARDING PERFORMANCE OF WORK. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAKING HIMSELF FAMILIAR WITH THE NATURE AND LOCATION OF ALL UNDERGROUND UTILITIES, PIPES AND STRUCTURES. THE CONTRACTOR SHALL TAKE SOLE RESPONSIBILITY FOR ALL COSTS INCURRED DUE TO DAMAGE AND/OR REPLACEMENT OF SAID UTILITIES, INCLUDING DELAYS. 5. ANY DISCREPANCIES BETWEEN THE FIELD CONDITIONS AND THE CONTRACT DOCUMENTS AND/OR THE DESIGN INTENT AFFECTING THE SUCCESSFUL COMPLETION AND COST OF THE PROJECT SHALL BE REPORTED TO THE OWNER (JOB SUPERINTENDENT) AND LANDSCAPE ARCHITECT IMMEDIATELY. ALL WORK RELATED TO THE PROBLEM ARE SHALL CEASE UNITIL THE DISCREPANCIES HAVE BEEN RESOLVED BY THE OWNER (JOB SUPERINTENDENT) OR LANDSCAPE ARCHITECT IN WRITING. ANY CONTINUATION OF WORK PRIOR TO THE RESOLUTION OF DISCREPANCIES IS AT THE CONTRACTOR'S RISK AND EXPENSE. 6. NO WORK SHALL BE PERFORMED WITHIN THE PUBLIC RIGHT-OF-WAY BY THE APPLICANT/OWNER, OR HIS OR HER AGENTS UNTIL A PUBLIC PROPERTY ENCROACHMENT PERMIT IS ISSUED BY THE CITY ENGINEER. 7. CONTRACTOR SHALL INSTALL THIS PROJECT IN ACCORDANCE TO ALL CITY CODES AND REQUIREMENTS. CONTRACTOR SHALL BRING TO THE ATTENTION OF THE OWNER AND THE LANDSCAPE ARCHITECT PRIOR TO CONSTRUCTION ANY KNOWN DISCREPANCY BETWEEN THAT WHICH IS SPECIFIED ON THESE PLANS AND THAT WHICH IS PERMITTED BY GOVERNING CODES AND THE HOME OWNERS' ASSOCIATION. 8. WITH THE ACCEPTANCE TO CONSTRUCT THIS PROJECT, CONTRACTOR AND OWNER AGREE TO HOLD LANDSCAPE ARCHITECT HARMLESS OF ANY UNFORESEEN CONSTRUCTION COSTS DUE TO ELEMENTS NOT SPECIFIED ON THESE PLANS. 9. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ALL SITE CONDITIONS PRIOR TO COMPLETING BIDS. CONTRACTOR SHALL INCLUDE IN THEIR BID THE COST OF ALL DEMOLITION AND ANY SOIL IMPORT AND OR EXPORT NEEDED TO COMPLETE THIS PROJECT. 10. CONTRACTOR SHALL INSTALL THIS PROJECT UTILIZING THE LANDSCAPE INDUSTRIES'S B.M.P. BEST MANAGEMENT PRACTICES. GENERAL MATERIAL SPECIFICATION: 1. GROUT CELLS WITH REINFORCED CEMENT PER ASTM C150. 1 PART PORTLAND CEMENT, 2 TO 3 PARTS LOOSE SAND, 2 PARTS COARSE AGGREGATE. 2. REINFORCING: FS = 20,000 PSI ASTM A615 GRADE 40. 3. MASONRY: FC = 1,500 PSI GRADE 'A' PER ASTM C150. 4. CONCRETE: FC = 3,500 PSI AT 28 DAYS CEMENT PER ASTM C150. 5. POUR ALL WALL FOOTINGS AGAINST NATURAL UNDISTURBED EARTH. 6. TELEPHONE LANDSCAPE ARCHITECT IF SITE CONDITIONS ARE NOT AS SHOWN. PROJECT HARDSCAPE MATERIALS: STONE SHOULD MATCH THE STONE USED ON THE HOUSE. PAVING STONE SHALL BE SHADOW GRAY SANDSTONE/QUARTZITE. ALL GROUT JOINTS SHALL BE PIGMENTED PER ARCH./G.C. APPROVAL. ALL HARDSCAPE MATERIAL SHALL RECEIVE 6 MIL. VISQUEEN ON UNDER SIDE FOR WATERPROOF PROTECTION. TOTAL LANDSCAPING AREA: 223 SQFT **ALL PLANTS TO BE DROUGHT-TOLERANT NON-INVASIVE PLANT SPECIES. PLANT HEIGHT 42" MAX. A 6.87' 7.31' 6.15' 6.31' 26.64 / 4 = 6.66' GP NO. REVISION DATENO. REVISION DATE 38 39 40 JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONSOWNER INFORMATION:PROJECT NAME STATUS These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT A-1.0 03/22/2019 2018-303-DIMENSIONAL VIEWSBAY FRONT TRADITIONAL BAY FRONTTRADITIONALSOUTH BAYFRONTWATERPOINTE, LLC.610 NEWPORT CENTERDRIVE, SUITE 890,NEWPORT BEACH, CA92660CDP -FIRST CHECK 400 S BAY FRONTNEWPORT BEACH, CA 92662CAITLIN SMITH 2 EAST AXON 4 SOUTH AXON 3 WEST AXON 1 NORTH AXON NO. REVISION DATE 41 UP DW T UP UPDN NEW WALL -2 x 6 STUDS @ 16" O.C. NEW WALL -2 x 4 STUDS @ 16" O.C. WALL W/. STONE VENEER -2 x 6 STUDS @ 16" O.C. CONCRETE RETAINING WALL -REF. STRUCTURAL CONCRETE MASONRY WALL -6" CMU U.N.O. DOUBLE WALL CONSTRUCTION -2 x 4 MIN. STAGGERED STUD @ 16" O.C. WINDOW -REFERENCE SCHEDULE DOOR -REFERENCE SCHEDULE CABINET -BUILT IN CASEWORK COLUMN -REF. STRUCTURAL DWGS. FURNITURE -FOR PRESENTATION PURPOSES ONLY FIREPLACE -PREFAB GAS-ONLY APPLIANCE PLUMBING FIXTURE -SINK (AS SELECTED) PLUMBING FIXTURE -TOILET (AS SELECTED) PLAN LEGEND LIGHTING FIXTURE -REFERENCE ELECTRICAL PLANS FIRE RATED CEILING ASS'Y. REF. DTL. 7/AD-1 INT. FIRE RATED PARTITION REF. DTL. 7/AD-1 EXT. FIRE RATED PARTITION REF. DTL. 5/AD-1 101 1i ?KEYNOTE TAG -REFERENCE KEYNOTE LEGEND THIS SHT. WINDOW TAG -REFERENCE SHEET A-7.0 DOOR TAG -REFERENCE SHEET A-7.0 WINDOW WALL TAG -REFERENCE SHEET A-7.01i 1.PROVIDE WHOLE BUILDING MECHANICAL VENTILATION PER ASHRAE STANDARD 62.2-2016 SECTION 4, WITH EXCEPTION THAT NATURAL VENTILATION THROUGH DOORS AND WINDOWS IS NOT AN ACCEPTABLE ALTERNATIVE TO WHOLE-BUILDING VENTILATION (BEES 152(a), EXCEPTION 5 TO SECTION 152(a)). FOR CONTINUOUS WHOLE-BUILDING VENTILATION, MIN. REQUIRED RATE OF VENTILATION IS 1 CFM FOR EACH 100 S.F. OF CONDITIONED FLOOR AREA PLUS 7.5 CFM FOR EACH OCCUPANT (ONE OCCUPANT PER BEDROOM +1). VENTILATION TO BE PROVIDED BY EXHAUST AIR, SUPPLY AIR OR COMBINED EXHAUST AND SUPPLY AIR. 2.PROVIDE IN KITCHEN LOCAL EXHAUST SYSTEM VENTED TO OUTDOORS WITH RATE = 100 CFM (PART OF WHOLE-BUILDING VENTILATION REQUIREMENT). MECHANICAL VENTILATION NOTE: CALCULATIONS: UNIT: 2,743 S.F. (0.03)2,743 S.F.+ [7.5 CFM x OCC. (BED. +1)] = 82.29 CFM + (7.5 x 4) = 112.29 CFM REQ'D. A-4.02 A-4.0 A-4.0 A-4.0 4 3 1 2 A-5.0 2 A-5.0 1 A-5.0 1 A-5.0 3 A-5.0 3 A-5.0 GREAT ROOM LOUNGE DINING KITCHEN FOYER ELEV. STAIRSC.C. POWDER 2- CAR GARAGE ENTRY PATIO 2 21 1 5' - 4 5/8"8' - 3 5/8"68' - 0 1/2"4' - 7" 6' - 7 3/4"16' - 9"17' - 1 1/2"11' - 8 3/4"22' - 5 1/4" 3' - 11 1/4"5' - 6 1/8"2' - 3 3/8"4' - 1 3/8"18' - 3 7/8"1' - 2"4' - 11 3/4"6"4' - 0 1/8"22' - 2 1/4"3' - 10"11' - 1 1/4"11' - 1"1' - 2"9' - 0"11 1/4"1' - 0 1/2"9' - 0"1' - 0 1/2"3 2 321 9 R @ 0' -9 3/8"3 7 1 87 65 6 5 10 4 8 8' - 3 5/8"69' - 2 1/4"3' - 5 1/4"5' - 4 3/4" 6' - 7 3/4"16' - 8 1/2"15' - 2"10' - 11 3/4"5' - 7 1/4"20' - 8 3/4" 1' - 2"4' - 11 3/4"6"3' - 3 3/8"2' - 9"5' - 4"2' - 9"2' - 7 1/8"2' - 7"10' - 0"2' - 7"1' - 0"6' - 10 3/4"2' - 1"1' - 0"4' - 0 3/8"1' - 6 7/8"7' - 2 1/8"8' - 9"4' - 9 3/4" 3 3/4"4' - 9 1/2"2' - 9 1/2"2' - 6"7"3' - 10"7' - 9"2' - 7 1/2"1' - 10 5/8"9' - 11 1/8"4' - 0 1/8"4' - 8 5/8"22' - 3 1/4"3' - 0 1/2"1' - 4 1/8"18' - 5"2' - 6 1/8"2' - 3 5/8"1' - 2"17' - 3"1' - 2"1' - 4 1/8"1' - 2"1 1/2"17' - 0"1 1/2"1' - 2"1' - 4 1/8"2' - 4 7/8"2' - 3 5/8"3' - 2 1/8"1' - 6 1/2"19' - 7 5/8"2' - 7 5/8"3' - 0 1/2"10 3/8"2' - 6 1/2"2' - 3"5' - 3 1/2"1' - 11 1/8"1' - 7 5/8"2' - 6 7/8"4' - 0"1' - 0"3' - 0 1/2"4' - 9 7/8"5' - 11 3/8"4' - 3 1/2"5' - 10 3/4"1' - 10 7/8"4' - 3 1/2"CLR.30" MIN.CLR. 2' - 7 3/4" CLR. 3' - 6"TYP.11"CLR.3' - 6"CLR. 3' - 6"CLR.3' - 6"CLR.3' - 6"TYP. 11" SLOPE PER CIVIL 1 2 3 1 2 3 4 523 6 7 3 8 9 2 10 10 11 12 13 14 15 16 R.Y.S.B. 5' - 0"S.Y.S.B.3' - 0"S.Y.S.B.3' - 0"NOTE: PROVIDE MIN 5/8" TYP 'X' ON ALL GARAGE WALLS 17 17 17 17 17 18 19 19 19 19 2021 BUILT-IN2223 CLR. 4' - 4 3/4"CLR.5' - 0 5/8"24 25 CLR.21' - 1"CLR. 19' - 8" CLR. 20' - 1"1' - 1 3/4" 3' - 5 1/4"S.Y.S.B.3' - 0"S.Y.S.B.3' - 0"S.Y.S.B.3' - 0"9.00' T.O.S. 9.00' T.O.S. 9.00' T.O.S. 4 1' - 0"CLR.3' - 0"CLR. 3' - 0" 11BUILT-IN48 50 50 50 50 51513535 3551 51 51 5" 1 A-5.1 1 A-5.1 2 A-5.1 2 A-5.1 3 A-5.1 3 A-5.1 8 AD-1 8 AD-15 AD-1 7 AD-1 7 AD-1 7 AD-1 8 AD-1 AD-1 22 AD-1 18 AD-1 1814 AD-1 9 AD-1 A-4.02 A-4.0 A-4.0 A-4.0 4 3 1 2 A-5.0 2 A-5.0 1 A-5.0 1 A-5.0 3 A-5.0 3 A-5.0 MASTER BATH W/C.BATH #2 ELEV.W.I.C. BEDROOM #2 BEDROOM #3 BATH #3W.I.C.LAUNDRY STAIRS MECH. W.I.C. MASTER SUITE M. BALCONY 2 21 1 5' - 4 5/8"8' - 3 5/8"68' - 0 1/2"4' - 7" 6' - 7 3/4"16' - 9"13' - 4"3' - 9"11' - 3 1/4"9' - 9 3/4"5' - 5 1/4"7' - 8 1/4" 4' - 9 7/8"2' - 10 3/8"2' - 3 7/8"8' - 11 3/8"5' - 1 7/8"4' - 7 7/8"3' - 5 3/8"10' - 6"2' - 9 5/8"1' - 2"4' - 11 3/4"6" 8' - 3 5/8"70' - 0 1/4"2' - 7 1/4"5' - 4 3/4" 6' - 7 3/4"16' - 8 1/2"15' - 2"10' - 11 3/4"13' - 7 1/4"13' - 6 3/4" 4' - 0 5/8"5' - 6"4' - 0 1/8"6 1/2"2' - 2 5/8"1' - 3"5' - 6"1' - 3"2' - 10 1/8"1' - 2"4' - 11 3/4"6"3' - 3 3/8"3' - 10"3' - 2"3' - 10"2' - 7 1/8"3' - 10"7' - 6"3 5/8"3' - 6 3/8"3 3/4"2' - 8"4' - 11 3/4"3' - 0 1/4"3' - 3 1/2"23' - 8 3/8"3' - 0 1/2"12' - 7 5/8"11' - 0 3/4"6' - 1 1/2"1' - 3 1/4"3' - 7 7/8"2' - 4 3/4"7' - 10 1/8"2' - 4 3/4"9 1/2"11 12 13 14 15 16 17 18 19 20 109 12 11 25 24 15 14 17 18 19 21 20 25 13 24 22 23 21224' - 8 5/8"22' - 3 1/4"3' - 0 1/2"2' - 7 5/8"8' - 6"8' - 6"2' - 7 5/8"1' - 4 1/8"1' - 2"1' - 4 1/8"1' - 2"162' - 4 7/8"2' - 3 5/8"1' - 6"10' - 0"3' - 10 3/4"8' - 4 1/2"1' - 9 5/8"1' - 9 5/8"5' - 1 1/8"3' - 11 3/8" 6 1/8" 5' - 10 5/8"4' - 9 1/2" 6' - 5"3' - 4 3/8"9' - 8 3/8" 5' - 0 5/8"4' - 9 1/8"1' - 6 1/2"2' - 2 1/8"3' - 8 3/4"5' - 8 1/8" 1' - 11 3/4"2' - 7 1/4" 5' - 1 1/8"8' - 2"2' - 0 3/4"2' - 11 1/8"4' - 3 1/8"3' - 1 3/4"9 1/2"4' - 8 5/8"1' - 11 1/8"4' - 2 7/8"1' - 1"1' - 8 3/8"9 1/8"7' - 10 1/8"2' - 2"9 1/8"CLR.11' - 6 3/8"7:12 7:12 CLR. ø 30 CLR. 30" MIN. CLR. 30" MIN. 1 2 9 8 26 7 CLR. 30" MIN.CLR.3' - 5 3/8"27 27 7 2 9 8 CLR. 3' - 6" CLR. 3' - 6"TYP.11"TYP. 11" CLR. 3' - 6"CLR.3' - 6"TYP.11"CLR. 3' - 6" 1 1 7 CLR.2' - 6"CLR. 4' - 5 1/4" 2 9 8 SEAT 28 28 28 SEATSEATCLR. 4' - 4 3/4"CLR.5' - 0 5/8"CLR. 2' - 6"CLR.3' - 0 1/4"R @ 0' -7 5/8"15 R @ 0' -7 1/2"15 11 29 12 12 12 30 30 30 2 31 3 8 32 33 2% MIN2% MIN2% MIN 2% MIN34 35 R.Y.S.B. 5' - 0"S.Y.S.B.3' - 0"S.Y.S.B.3' - 0"36 36 36 17 17 17 18 18 1919 19 41 42 43 40 18.58' 19.58' R @ 0' -6"2CLR.3' - 6"TYP. 11" 18.58' 45 23 1' - 10 1/2"1' - 10 1/2" CLR.3' - 7" CLR. 6' - 0"CLR.4' - 3 1/2"21' - 2"1' - 6"2' - 6"8' - 0"2' - 6"1' - 6" 47 1 12 MAX6"52 MAX.6"1 A-5.1 1 A-5.1 2 A-5.1 2 A-5.1 3 A-5.1 3 A-5.1 14 AD-1 13 AD-1 13 AD-1 13 AD-1 AD-1 17 AD-1 17 AD-1 17 MECH. SHAFTMECH. SHAFT5 AD-1 AD-1 18 A-4.02 A-4.0 A-4.0 A-4.0 4 3 1 2 A-5.0 2 A-5.0 1 A-5.0 1 A-5.0 3 A-5.0 3 A-5.0 BATH #4 BONUS ROOM STAIRS ELEV. ROOF DECK VIEW DECK 2 21 1 6:126:126:126:126:127:12 7:12 7:127:127:127:127:127:12 7:1212:12 12:1212:128' - 2 3/8"21' - 10"7' - 2"11' - 7 1/2"3' - 0"2' - 10"5' - 9 1/2"3' - 0 1/2"18' - 9 1/2"8' - 2 3/8"7' - 5 1/8"11' - 4 3/8"5' - 6 1/8"5' - 10 1/4"5' - 4 5/8"37' - 6 1/2"23' - 6 3/4"19' - 9 7/8" 4' - 7 1/8"11' - 3 1/4"7' - 8 3/8" 2' - 3 5/8"8' - 2 1/4"5' - 4 5/8"5' - 6 1/4"2' - 2 1/8" SPA (BY SEP. PERMIT) NOT TO EXCEED MAX FLAT PATH OF EGRESS 25' - 8 1/2" PATH OF EGRESS 3' - 5 1/4"PATH OF EGRESS6' - 6"PATH OF EGRESS 4' - 7 1/4"PATH OF EGRESS2' - 11 7/8"CLR. 30" MIN. 37' - 6 1/2"23' - 6 3/4"19' - 9 7/8"5' - 4 3/4" 7' - 8 7/8"15' - 9 7/8" 2' - 11 3/8"4' - 9 1/2"2' - 10 1/8"9' - 11 1/8"3' - 0 5/8" 2 % MIN2 % MIN 2 % MIN2 % MIN2 % MIN 2 % MIN2 % MIN2 % MIN 2 % MIN2 % MIN2 % MIN 2 % MIN2 % MIN 2 % MIN2 % MIN 2 % MIN2 % MIN2 % MIN 2 % MINCLR. ø 3' - 0" PATH OF EGRESS 25' -8 1/2" + 3' -5 1/4" + 6' -6" + 4' -7 1/4" +2' -11 7/8" = 35' -10 7/8" CLR. 4' - 4 3/4"CLR.5' - 0 3/4"MECH.CLR.2' - 6"CLR. 4' - 3 3/8" 7 927 2 26 28 29 28 29 27 3031 CLR. 3' - 6" TYP. 11"CLR.3' - 6"TYP.11"CLR. 3' - 6"TYP.11"CLR.3' - 6"CLR. 3' - 6"CLR.3' - 6"CLR. 3' - 6" 26 R @ 0' -7 1/2"15 12 37 38 FIRE PIT (BY SEP. PERMIT) 39 11 6 40 40 4040 40 40 4343 44 44 44 44 44 44 44 44 4430' - 0 3/8"DN. UP SEAT 46 49 49 11 7:12 7:12 6:12 6:12 46 46 1 1 A-5.1 1 A-5.1 2 A-5.1 2 A-5.1 3 A-5.1 3 A-5.1 16 AD-1 15 AD-1 15 AD-1 AD-1 11 AD-1 11 AD-1 11 14 AD-1 14 AD-1 9 AD-1 JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONSOWNER INFORMATION:PROJECT NAME STATUS These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT A-2.0 05/01/2019 2018-30FLOOR PLANBAY FRONT TRADITIONAL BAY FRONTTRADITIONALSOUTH BAYFRONTWATERPOINTE, LLC.610 NEWPORT CENTERDRIVE, SUITE 890,NEWPORT BEACH, CA92660FIRST CHECK 400 S BAY FRONTNEWPORT BEACH, CA 92662CAITLIN SMITH STAIRWAY NOTE: ALL STAIRWAYS SHALL HAVE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT CANDLE PER CRC R303.7 KEYNOTE LEGEND 1 FURNISHINGS - AS SELECTED 2 COUNTERTOP - AS SELECTED 3 BASE CABINET - BUILT-IN, FINISH AS SEL. 4 DOUBLE OVEN - AS SELECTED 5 KITCHEN EXHAUST HOOD - PROVIDE MIN. RATE OF 100 CFM - INSTALL & PROVIDE POWER PER MFGR'S. INSTRS. 6 RESIDENTIAL ELEVATOR - 'GARAVENTA LIFT, UPGRADE DOOR PACKAGE STYLE 5,' SHAFT SIZE = 62" X 63 1/2" CLEAR, SLAB DEPRESSION REQ'D PER MFGR. - PROVIDE SHOP DWGS. TO ARCH. PRIOR TO PURCHASE & INSTALLATION 7 TOILET - MIN. 24" CLR. IN FRONT, MIN. 30" CLR. WIDTH, REF. CAL GREEN NOTES FOR FLOW RATE INFO. 8 BASE CABINET - SINK UNIT, BUILT-IN, FINISH AS SEL. 9 SINK - AS SELECTED (VERIFY COUNTER OR WALL MOUNT FIXTURES W/. OWNER) 10 WATER HEATER - TANK-LESS (ON DEMAND) WALL-MOUNT +44" MIN., 'TAKAGI' OR EQUIV. - VERIFY SIZE REQ'D. W/. MFGR. (PROVIDE ADEQUATE N.G. CONN.) VENT THROUGH ROOF 11 STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT CANDLE (CBC 1205.4) REF. DTL. 3/AD-1 12 INTERIOR HANDRAIL - 34" - 38" ABV. NOSING (36" TYP. U.N.O.), REF. DTLS. 4 & 9/AD-1 13 ENCLOSED USEABLE SPACE UNDER STAIRWAY USE 5/8" TYPE 'X' GYP. BD. FINISH TYP. (1/2" MIN.) (CRC R302.7) 14 REFRIGERATOR - VERIFY APPLIANCE W/. OWNER 15 VEHICLE - MINIMUM PARKING DIMENSIONS ON PLANS 16 MAIN SERVICE PANEL, 400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION) - VERIFY LOC'N. W/. SO. CA. EDISON 17 PROPERTY LINE 18 REAR YARD SETBACK 19 SIDE YARD SETBACK 20 KITCHEN SINK - AS SELECTED 21 DISHWASHER - AS SELECTED 22 FIREPLACE - PREFABRICATED, GAS ONLY, 'TOWN AND COUNTRY,' MODEL TC42 [DTL. 22/AD-1] (FACTORY BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR COMPONENTS SHALL BE LISTED AN INSTALLED IN ACCORDANCE W/. THEIR LISTING AND MFG'R. INSTALLATION INSTRUCTIONS. GASEOUS FUEL BURNING PAN MUST BE PERMANENTLY ANCHORED TO THE FIREBOX. FIREPLACE MUST COMPLY W/. THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES.) 23 CHIMNEY SHALL EXTEND AT LEAST 2' HIGHER THAN ANY PORTION OF THE BUILDING W/IN. 10', BUT SHALL NOT BE LESS THAN 3' ABV. THE HIGHEST POINT WHERE THE CHIMNEY PASSES THRU THE ROOF (CBC 2113.9) 24 1-3/8" MIN. SOLID CORE DOOR, SELF CLOSING & SELF LATCHING (R302.5.1) 25 7 - 3/4" MAX STEP AT IN SWING DOORS (R311.3.1) - REF CIVIL FOR STEP HEIGHT 26 BATHTUB - AS SELECTED (VERIFY LOC'N. OF FIXTURES W/. OWNER) 27 TEMPERED GLASS ENCLOSURE - 1/2" THK. (MIN. 3/8" THK.) GLASS TO BE ETCH MARKED (FRAMELESS U.N.O.) 28 SHOWER - HOT-MOP PAN, PROVIDE TILE W/. CEMENT BACKING MIN. 72" HIGH; NET AREA 7.1 S.F. MIN.; 30" DIA. CIRCLE MIN., REF. DTL. 17/AD-1 29 INTERIOR GUARD - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTLS. 4 & 9/AD-1 30 EXTERIOR GUARDRAIL - MIN. 42" HEIGHT 31 LAUNDRY SINK - AS SEL. 32 WASHER - PROVIDE HOOK-UPS & POWER - INSTALL PAN & DRAIN UNDER WASHER (TYP.) - G.C. TO VERIFY LOC'N. & SIZE 33 UPPER CABINET - BUILT-IN, FINISH AS SEL. 34 DECK/BALCONY DRAIN - SLOPE 2% MIN. - REF. DTL. 11/AD-1 35 OVERFLOW DRAIN LINE - IN WALL/ FROM ABV., TO BE METAL VERIFY W/. G.C. (REF. CIVIL DWGS. & DTLS.) 36 WOOD. CAP - SLOPE 2% MIN., - SEAL AND PAINT AS SEL - ARCH. TO APPV." 37 STAIR MOUNTED HANDRAIL (34" - 38" ABV. NOSING, 36" TYP.), SIM. TO DTL. 2/AD-1 38 INTERIOR GUARD - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTLS. 4 & 18/AD-1 39 BBQ, AS SEL. - PROVIDE NATURAL GAS 40 WESTCOAT ALX' WATERPROOF MEMBRANE PER ICC# ESR-2201 41 METAL GUTTER - KYNAR FINISH OR EQUIV., SHAPE AS SEL. - PROVIDE SHOP DWGS. TO ARCH. PRIOR TO FAB. 42 ROOF FASCIA - EAVE AS DIMENSIONED (REF. ROOF PLAN & RCP FOR DETAILS) 43 ROOF - STANDING SEAM METAL W/. SS. METAL ZINC FINISH - REF. MAT. SCHED. A-4.0 & DTL. 2/A-3.0 44 SLATE ROOFING PER MATERIAL SCHEDULE A-4.0 AND DTL 3/A-3.0. 45 WINDOW TO MEET EGRESS REQ'TS. - REF. WINDOW NOTE #6 ON SCHEDULE 46 EXTERIOR GLASS GUARD - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTLS. 13/AD-1 47 A/C. CONDENSER UNIT - SIZE TBD - PROVIDE POWER AND SOUND DAMPENING PAD AS REQ'D. (SOUND ATT. REQ'D. BY C.N.B.) - "UNIT B" EQUIPMENT ONLY, SEP. PERMIT REQ'D 48 CUSTOM BUILT KITCHEN ISLAND PER OWNER & ARCH. 49 1-1/2" MAX. STEP AT OUT SWING DOORS (R311.3.1) 50 LINE OF SECOND FLOOR ABOVE 51 DRAIN LINE - IN WALL/FROM ABV., TO BE METAL VERIFY W/. G.C. (REF. CIVIL DWGS. & DTLS.) 52 LINE OF ROOF ABOVE DIMENSION NOTE: ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE NEAREST 1/8" -CONTACT ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS. 1/4" = 1'-0"1 FIRST FLOOR PLAN 1/4" = 1'-0"2 SECOND FLOOR PLAN *HERS VERIFICATION REQUIRED-REFERENCE T-24.1 A ROUGH FRAMING: ALL EXTERIOR WALLS TO BE FRAMED WITH 2 X 6 STUDS SECOND AND THIRD FLOOR PLYWOOD TO BE 1-1/8" ENTIRE EXTERIOR TO BE SHEATHED WITH 1/2" PLYWOOD NO. REVISION DATE 1/4" = 1'-0"3 THIRD FLOOR PLAN 42 UP ROOF VENTILATION NOTES: (CRC R806) 1.ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE ENTRANCE OF RAIN OR SNOW. VENTILATION OPENINGS SHALL HAVE AT LEAST DIM. OF 1/16" MIN. AND 1/4" MAX. VENTILATION OPENINGS HAVING A LEAST DIMENSION LARGER THAN 1/4" SHALL BE PROVIDED W/. CORROSION-RESISTANT WIRE CLOTH SCREENING, HARDWARE CLOTH, OR SIMILAR MATERIAL WITH OPENINGS HAVING A LEAST DIM. OF 1/16" MIN. AND 1/4" MAX. OPENINGS IN ROOF FRAMING MEMBERS SHALL CONFORM TO THE REQ'TS. OF CRC R802.7. REQUIRED VENTILATION OPENINGS SHALL OPEN DIRECTLY TO THE OUTSIDE AIR. 2. THE NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1/150 OF THE AREA OF THE SPACE VENTILATED. THE NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1/300 IF ONE OR MORE OF THE FOLLOWING ARE MET; 1. IN CLIMATE ZONES 14 & 16, A CLASS I OR II VAPOR RETARDER IS INSTALLED ON THE WARM-IN-WINTER SIDE OF THE CEILING. 2. AT LEAST 40% AND MORE THAN 50% OF THE REQUIRED VENTILATING ARE IS PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE ATTIC OR RAFTER SPACE. UPPER VENTILATORS SHALL BE LOCATED NO MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE, MEASURED VERTICALLY, WITH THE BALANCE OF TEH REQUIRED VANTILATION PROVIDED BY EAVE OR CORNICE VENTS. WHERE THE LOCATION OF WALL OR ROOF FRAMING MEMBERS CONFLICTS WITH THE INSTALLATION OF UPPER VENTILATORS, INSTALLATION MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST OF THE SPACE SHALL BE PERMITTED. 3. WHERE EAVE OR CORNICE VENTS ARE INSTALLED, INSULATION SHALL NOT BLOCK THE FREE FLOW OF AIR. A MIN. OF A 1" SPACE SHALL BE PROVIDED BETWEEN THE INSULATION AND THE ROOF SHT'G. AND AT THE LOCATION OF THE VENT. 4. VENTILATORS SHALL BE INSTALLED IN ACCORDANCE WITH MFR'G.'S INSTALLATION INSTRUCTIONS. INSTALLATION OF VENTILATORS IN ROOF SYSTEMS SHALL BE IN ACCORDANCE W/. THE REQ'TS. OF SECTION R903. INSTALLATION OF VENTILATORS IN WALL SYSTEMS SHALL BE IN ACCORDANCE W/. THE REQ'TS. OF SECTION R703.1. 5. UNVENTED ATTIC ASSEMBLIES (SPACES BETWEEN THE CEILING JOISTS OF THE TOP STORY AND THE ROOF RAFTERS) AND UNVENTED ENCLOSED RAFTER ASSEMBLIES (SPACES BETWEEN CEILINGS THAT ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF FRAMING MEMBER/RAFTERS AND THE STRUCTURAL ROOF SHT'G. AT THE TOP OF THE ROOF FRAMING MEMBERS/RAFTERS) SHALL BE PERMITTED IF ALL OF THE FOLLOWING CONDITIONS ARE MET: 1. THE UNVENTED ATTIC SPACE IS COMPLETELY CONTAINED WITHIN THE BUILDING THERMAL ENVELOPE. 2. NO INTERIOR CLASS I VAPOR RETARDERS ARE INSTALLED ON THE CEILING SIDE (ATTIC FLOOR) OF THE UNVENTED ATTIC ASSEMBLY OR ON THE CEILING SIDE OF THE UNVENTED ENCLOSED RAFTER ASEEMBLY. 3. WHERE WOOD SHINGLES OF SHAKES ARE USED, A MIN. 1/4" VENTED AIR SPACE SEPARATES THE SHINGLES OR SHAKES AND THE ROOFING UNDERLAYMENT ABOVE THE STRUCTURAL SHT'G. 4. IN CALIFORNIA CLIMATE ZONES 14 & 16, ANY AIR- IMPERMEABLE INSULATION SHALL BE A CLASS II VAPOR RETARDER, OR SHALL HAVE A CLASS III VAPOR RETARDER COATING OR COVERING IN DIRECT CONTACT W/. THE UNDERSIDE OF THE INSULATION (SEE TITLE 24, PART 6, FIG. 100.1-A) 5. EITHER ITEMS 5.1, 5.2 OR 5.3 SHALL BE MET, DEPENDING ON THE AIR PERMEABILITY OF THE INSULATION DIRECTLY UNDER THE STRUCTURAL ROOF SHT'G. (NO INSULATION SHALL BE REQ'D. WHEN ROOF TILES, WOOD SHINGLES OR WOOD SHAKES, OR ANY OTHER ROOFING SYSTEM USING BATTENS AND NO CONT. UNDERLAYMENT IS INSTALLED. A CONT. LAYER SHALL BE CONSIDERED TO EXIST IF SHT'G., ROOFING PAPER OR ANY CONT. LAYER WHICH HAS A PERM RATE OF NO MORE THAN ONE PERM UNDER THE DRY CUP METHOD.); 5.1. AIR-IMPERMEABLE INSULATION ONLY. INSULATION SHALL BE APPLIED IN DIRECT CONTACT W/. THE UNDERSIDE OF THE STRUCTURAL ROOF SHT'G. 5.2. AIR-PERMEABLE INSULATION ONLY. IN ADDITION TO THE AIR-PERMEABLE INSULATION INSTALLED DIRECTLY BELOW THE STRUCTURAL SHT'G., RIDGE BOARD OR SHEET INSULATION W/. AN R-VALUE OR R-4 SHALL BE INSTALLED DIRECTLY ABOVE THE STRUCTURAL ROOF SHT'G. FOR CONDENSATION CONTROL. 5.3. AIR-IMPERMEABLE AND AIR-PERMEABLE INSULATION. THE AIR-IMPERMEABLE INSULATION SHALL BE APPLIED IN DIRECT CONTACT W/. THE UNDERSIDE OF THE STRUCTURAL ROOF SHT'G. FOR CONDENSATION CONTROL. THE AIR-PERMEABLE INSULATION SHALL BE INSTALLED DIRECTLY UNDER THE AIR-PERMEABLE INSULATION. 5.4. WHERE PREFORMED INSULATION BOARD IS USED AS THE AIR IMPERMEABLE INSULATION LAYER, IT SHALL BE SEALED AT THE PERIMETER OF EACH INDIVIDUAL SHEET INTERIOR SURFACE TO FORM A CONT. LAYER. FILLED REGION INDICATES ATTIC SPACE-REF. ATTIC VENTILATION CALCS. ROOF PLAN LEGEND A-4.02 A-4.0 A-4.0 A-4.0 4 3 1 2 A-5.0 2 A-5.0 1 A-5.0 1 A-5.0 3 A-5.0 3 A-5.0 2 21 1 8 3/4"F.O.F.2' - 3 3/4"F.O.F. 7' - 6 7/8"8 3/4"F.O.F.4' - 1 3/8"3 1/4"F.O.F. 1' - 2 1/8"5 3/4" 5' - 4 5/8"F.O.F.5' - 9 1/2"3 1/4"F.O.F. 7' - 6 7/8"8 3/4"F.O.F.3' - 11 7/8"8 3/4"F.O.F.3' - 11 7/8"8 3/4"8 3/4"F.O.F.2' - 6 3/4"7 7/8"1' - 8 7/8"F.O.F.2' - 6 3/4"F.O.F.2' - 6 3/4"8 3/4"8 3/4"F.O.F.2' - 0 1/4"5 1/4"8 3/4"F.O.F.2' - 6 3/4"8 3/4"5 1/4"F.O.F.2' - 0 1/4"8 3/4"8 3/4"F.O.F.2' - 6 3/4"8 3/4"5 3/4" F.O.F. 2' - 1 1/2"5' - 4 3/4"8 3/4"8 3/4" F.O.F. 3' - 10 1/4"F.O.F.2' - 3 3/4"8 3/4"5 3/4"F.O.F.2' - 6 3/4"5 3/4"8 3/4" F.O.F. 19' - 1 1/8" 5 3/4" F.O.F. 19' - 4 1/8"9' - 8 3/4"5 3/4"5 3/4"8 3/4"F.O.F.7' - 5 5/8"8 3/4"F.O.F.7' - 5 5/8"6:126:126:127:12 7:12 6:126:12 6:126:12 5:125:12 3:123:123:12 3:12 5:12 5:123:123:127:127:127:127:12 7:12 7:1212:12 12:1212:1237.90' 37.21' 37.79' 33.00' 33.04' 31.69'31.69' 33.78' 33.98' 33.00' 37.77' 37.90' 33.00' HT. CERT. REQ'D HT. CERT. REQ'D HT. CERT. REQ'D VIEW DECK (REF. SHEET A-3.0) VIEW DECK (REF. SHEET A-3.0) HT. CERT. REQ'D HT. CERT. REQ'D HT. CERT. REQ'D HT. CERT. REQ'D HT. CERT. REQ'D HT. CERT. REQ'D HT. CERT. REQ'D 1 1 2 2 2 2 2 2 2 2 2 2 2 3 3 3 4 4 4 4 4 5 5 5 5 5 5 5 5 5 6 6 6 6 6 7 5 7 6 7 6 5 7 7 7 5 7 8 9 10 33.00' 33.00' R.Y.S.B. 5' - 0"3' - 0"2x ROOF RAFTER (PER STRUCT.) INTERIOR FINISH (PER PLANS, WHERE OCCURS) AIR-PERMEABLE INSULATION (PER PLANS) MIN. 30# ROOF FELT-(2) LAYERS GAF VERSASHIELD UNDERLAYMENT 15/32" CDX PLYWD. SHT'G. MIN. (REF. STRUCT) FASTENERS PER MFGR. INSTRUCTIONS 12 SLOPE PER PLAN STANDING SEAM METAL (ZINC OR EQUIV.) -REF. MAT. SCHED. A/A-5, CLASS 'A' ASSY. TYP.6" - 10"6" MIN. DOUBLE FOLD 3/4" LOCK, ALT. METHOD CLEATS @ 18" O.C. MAX. CONT. LOCK STRIP, SOLDERED ARCH. TO APPV. 12"-16"1-1/2" HIGHVALLEY DETAIL PRODUCT LISTING: ICC # ESR-2048, CB-150 UNVENTED ENCLOSED RAFTER ASSEMBLY NOTE: NO INTERIOR CLASS I VAPOR RETARDER SHALL BE INSTALLED ON THE CEILING SIDE (ATTIC FLOOR) OF THE UNVENTED ATTIC ASSEMBLY OR ON THE CEILING SIDE OF THE UNVENTED ENCLOSED ROOF FRAMING ASSEMBLY. 1/4" DENSGLASS OR EQUIV. 2x ROOF RAFTER (PER STRUCT.) INTERIOR FINISH (PER PLANS, WHERE OCCURS) AIR-PERMEABLE INSULATION (PER PLANS) MIN. 2 LAYERS 15# ROOF FELT O/. CAP SHT. 1/2" CDX PLYWD. SHT'G. MIN. (REF. STRUCT) SHINGLES TO BE NO. 1 GRADE WESTERN RED CEDAR W/. A MAX. MOISTURE CONTENT OF 25% FASTENERS PER NOTE #3 LENGTH TO BE DETERMINED BY UNDERLAYMENT LAYER, REF. NOTE #5 (2) PER SHINGLE/SHAKE 12 SLOPE PER PLAN (MIN. 4:12 SHAKES) (MIN. 3:12 SHINGLES) WOOD SHINGLE NOTES: 1. SHINGLES TO BE INSTALLED ON SOLID SHT'G. IN ACCORDANCE WITH CBC TABLE 1507.8 2. FASTENERS MUST BE HOT-DIPPED GALVANIZED W/. ZINC COATING WTS. IN ACC. W/. ASTM A 153, OR S.S. 3. 'FSR TREATMENT, INC.' CLASS 'A' ROOFING ASS'Y. ICC# ESR-1410 STARTER COURSES AT THE EAVE MUST BE DOUBLED, W/. FIRST COURSE BEING FULL-SIZE TREATED SHINGLES, SUPPLIED BY 'CHEMCO, INC.' 15" OR 18" TREATED SHINGLES MAY BE USED FOR THE FINAL COURSE AT THE RIDGE. 4. PRODUCTS LISTED AS 'CLASS B' SHINGLES MUST BE INSTALLED O/. SPACED OR SOLID SHT'G. COVERED EITHER W/. ONE LAYER OF 1-1/4" DENS-DECK ROOF BOARD, MANUFACTURED BY GEORGIA PACIFIC CORP., OR W/. ONE LAYER MINERAL-SURFACED CAP SHEET COMPLYING W/. ASTM D 3909. WHERE UNDERLAYMENT IS REQ'D., THE UNDERLAYMENT SHALL BE INSTALLED OVER THE DENS-DECK BOARD OR MINERAL-SURFACED CAP SHEET. FASTENER LENGTH FOR THE SHAKES MUST BE INCREASED FOR THE THICKNESS OF THE DENS-DECK BOARD OR CAP SHEET. THE DENS-DECK BOARDS MUST BE FASTENED TO SPACED OR SOLID SHT'G. USING A MIN. OF FOUR FASTENERS PER BOARD TO AVOID PANEL SHIFTING PRIOR TO INSTALLATION OF THE SHAKES. THE MINERAL-SURFACED CAP SHEET MUST BE INSTALLED WITH 2" OVERLAPS ON THE SIDES AND ENDS, AND ATTACHED W/. A SUFFICIENT NUMBER OF FASTENERS TO HOLD THE SHEET IN PLACE PRIOR TO INSTALLATION OF THE SHAKES. 5. MIN. CAP SHT. -REF. NOTE #5 ABV. EXPOSURE & OVERLAP PER CBC TABLE 1507.8.6 AUTOMATIC SPRINKLERS TO BE INSTALLED THROUGHOUT & IN ATTIC AREAS IN ACCORDANCE WITH C.N.B. STANDARDS (PROVIDE SEPARATE APPLICATION, REF. 8/T-1) 6. EAVES TO BOXED 1-HR. ASSEMBLY PER NBMC 15.04.2207. UNVENTED ENCLOSED RAFTER ASSEMBLY NOTE: 1. AT UNVENTED ENCLOSED RAFTER ASSEMBLY PROVIDE 1X SLEEPER OVER ROOF UNDERLAYMENT FOR MIN. 1/4" VENTED AIR SPACE SEPARATE WOOD SHAKE OR SHINGLE AND ROOFING UNDERLAYMENT TO MEET REQUIREMENT OF THE SECTION R806.5 OF CBC 2. NO INTERIOR CLASS I VAPOR RETARDER SHALL BE INSTALLED ON THE CEILING SIDE (ATTIC FLOOR) OF THE UNVENTED ATIIC ASSEMBLY OR ON THE CEILING SIDE OF THE UNVENTED ENCLOSED ROOF FRAMING ASSEMBLY. JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONSOWNER INFORMATION:PROJECT NAME STATUS These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT A-3.0 03/22/2019 2018-30ROOF PLANBAY FRONT TRADITIONAL BAY FRONTTRADITIONALSOUTH BAYFRONTWATERPOINTE, LLC.610 NEWPORT CENTERDRIVE, SUITE 890,NEWPORT BEACH, CA92660CDP -FIRST CHECK 400 S BAY FRONTNEWPORT BEACH, CA 92662CAITLIN SMITH KEYNOTE LEGEND 1 WESTCOAT ALX' WATERPROOF MEMBRANE PER ICC# ESR-2201 2 SLATE ROOFING PER MATERIAL SCHEDULE A-4.0 AND DTL 3/A-3.0. 3 ROOF - STANDING SEAM METAL W/. SS. METAL ZINC FINISH - REF. MAT. SCHED. A-4.0 & DTL. 2/A-3.0 4 EXTERIOR GLASS GUARD - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTLS. 13/AD-1 5 ROOF FASCIA - EAVE AS DIMENSIONED (REF. ROOF PLAN & RCP FOR DETAILS) 6 METAL GUTTER - KYNAR FINISH OR EQUIV., SHAPE AS SEL. - PROVIDE SHOP DWGS. TO ARCH. PRIOR TO FAB. 7 LINE OF WALLS BELOW 8 CHIMNEY CAP/SPARK ARRESTOR - AS SELECTED (NOTE: DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT THE TERMINATION OF FACTORY BUILT CHIMNEYS EXCEPT WHERE SUCH SHROUDS ARE LISTED AND LABELED FOR USE WITH THE SPECIFIC FAC. BLT. CHIMNEY SYSTEM AND ARE INSTALLED IN ACCORDANCE W/. MFGR. INST. INSTRUCTIONS. CMC 802.4.2.4) 9 CHIMNEY SHALL EXTEND AT LEAST 2' HIGHER THAN ANY PORTION OF THE BUILDING W/IN. 10', BUT SHALL NOT BE LESS THAN 3' ABV. THE HIGHEST POINT WHERE THE CHIMNEY PASSES THRU THE ROOF (CBC 2113.9) 10 CRICKET - SLOPE 2% MIN., REF. ROOF PLAN A-4 1/4" = 1'-0"1 ROOF PLAN NOTE:ALL DIMS. ARE TO FACE OF STUD (F.O.S.) OR FACE OF SHT'G. (F.O.S.) TYP. U.N.O. EAVE DIMS. ARE FROM FACE OF SHT'G. TO FACE OF FINISH FASCIA A 1 1/2" = 1'-0"3 METAL ROOFING DETAIL NO. REVISION DATE 1 1/2" = 1'-0"2 WOOD SHINGLE ROOFING 43 WINDOWS & DOORS: AUTHORIZED DEALER (PRODUCTS LISTED BELOW) SUPPLIER: ASSOCIATED BUILDING SUPPLY ADDRESS: STONE MILL DESIGN CENTER 2915 RED HILL AVE., SUITE F104, COSTA MESA, CA 92626 CONTACT: JOE YOUNAN PHONE: 949-872-3319 FAX: 206-666-2150 EMAIL: JYOUNAN@ABSSOCAL.COM WEB: WWW.ASSOCIATEDBUILDINGSUPPLY.COM ALUMINUM CLAD WINDOWS & PATIO DOORS MANUFACTURER: JELD-WEN WINDOWS & DOORS PRODUCT: CUSTOM COLLECTION ADDRESS: 3250 LAKEPORT BLVD. P.O. BOX 1329; KLAMATH FALLS, OREGON 97601 PHONE: 541-885-7412 OR 800-535-3936 FAX: 541-884-3331 WEB: WWW.JELD-WEN.COM MULTI SLIDE DOORS & STOREFRONT MANUFACTURER: WESTERN WINDOW SYSTEMS PRODUCT: SERIES 600 & STOREFRONT SYSTEMS ADDRESS: 5621 S. 25TH ST., PHOENIX, AZ 85040 PHONE: 877.268.1300 WEB: WWW.WESTERNWINDOWSYSTEMS.COM GUTTERS: GARAGE DOORS: SUPPLIER:RANCH HOUSE DOORS WWW.RANCHHOUSEDOORS.COM STYLE: CUSTOM MATERIAL: CUSTOM BUILT, WOOD & GLASS WATERPROOF DECK MEMBRANE: FLASHING & WEATHERSTRIPPING: ROOFING (METAL): MANUFACTURER: CUSTOM-BILT METALS 13940 MAGNOLIA AVE. CHINO, CA 91710 P: 909.664.1500 PRODUCT: STANDING SEAM ZINC ROOFING, CB-150 COLOR: NATURAL ZINC NOTES:USE CONTINUOUS 16" OR 18" PANS -VERIFY W/. ARCH. SIZE & LOC'N. OF SEAMS. (NO TRANSVERSE SEAMS) REF. DTL. 1/A-3 WEIGHT:APPX. 2 PSF. CODE: ICC # ESR-2048, CB-150 MATERIAL: METAL -ALUM. PAINTED KYNAR SHAPE: HALF ROUND (5") (VERIFY W/. ARCH.) TUFFLEX POLYMERS 10880 POPLAR AVE. FONTANA, CA P: 909.349.2016 WWW.TUFFLEXPOLYMERS.COM CODE: ICC # ESR-2505 PROVIDE MIN. 24 GUAGE METAL (16 OZ.) SHEETING (TO MATCH) FOR ALL EXTERIOR FLASHING & WEATHERSTRIPPING APPLICATIONS. VERIFY W/. ARCHITECT ANY UNCONVENTIONAL ENVELOPE WATERPROOFING AREAS PRIOR TO INSTALLATION. ROOFING (WOOD): PRODUCT:WOOD SHINGLE -FIRE TREATED MFGR:FSR TREATMENT, INC. WWW.FIRESMARTROOFING.COM COLOR:NATURAL APPLICATION: CLOSED VALLEY W/. MITERED HIP CUTS, 16 GAUGE COPPER FLASHING, STAGGERED COURSING (REF. DTL. 2/A-3) CODE:CLASS A ASSEMBLY (ICC# ESR-1410) WEIGHT:N/A WOOD SHINGLE SIDING: MANUFACTURER: (TBD) SPECIES: #1 WESTERN RED CEDAR SIZE: 18" RE-BUTTED & RE-JOINED PERFECTION SHINGLES (100% EDGE GRAIN, 100% CLEAR) 5 1/2" EXPOSURE TREATMENT: PRE-STAINED W/. CABOT BLEACHING OIL (VERIFY W/. OWNER) APPLICATION: PER DETAIL 5/AD-1, NO EDGE BOARDS, MITERED 'SAWTOOTH' CORNERS 16" SHINGLES W/. 5.5" EXPOSED BOARD & BATTEN PRODUCT: WOOD MDX MANUFACTURER: TBD COLOR: COLOR AS SEL. (ARCH. TO APPV.) APPLICATION: PER DETAIL 16/AD-1 CODE: NA WOOD FASCIA & TRIM: MFGR: WINDSORONE COLOR" PAINTED WHITE (VERIFY W/. OWNER) APPLICATION: ARCH TO APPV. PROFILES EXTERIOR STONE VENEER SUPPLIER: SEPULVEDA BUILDING MATERIAL 28092 FORBES ROAD LAGUNA NIGUEL, CA. 92677 P: 949.347.2100 STONE TYPE:TBD COLOR: LT. BEIGE & WHITE, COLOR GROUT TO MATCH APPLICATION: 24" X 48" TILE, TIGHT GROUT THICKNESS: 1" -1.5" NOMINAL WEIGHT: LESS THAN 15 LBS./S.F. FIRST FLOOR (T.O.S.) 9.00' FIRST FLOOR (T.O.S.) 9.00' MAX. RIDGE HEIGHT 38.00' MAX. RIDGE HEIGHT 38.00' MASTER FLOOR PLATE (TYP.) 18.50' MASTER FLOOR T.O.S. (TYP.) 19.58' ROOF PLATE (TYP.) 35.83' ROOF PLATE (TYP.) 35.83' NAVD 88 9.00' NAVD 88 9.00' MAX FLAT 33.00' MAX FLAT 33.00' THIRD FLOOR PLATE 27.42'THIRD FLOOR PLATE 27.42' THIRD FLOOR T.O.S. 28.50' THIRD FLOOR T.O.S. 28.50' DECK FLOOR PLATE 28.45' DECK T.O.S.(TYP.) 29.33' MASTER ROOF PLATE (TYP.) 28.58' MASTER ROOF PLATE (TYP.) 28.58' GARAGE 6.83' 1 A-5.0 3 A-5.0 SECOND FLOOR PLATE (TYP.) 17.50' SECOND FLOOR T.O.S. (TYP.) 18.58' 2 2 1 1 17 16 30 29 15 14 13 12 11 10 9 8 7 1 6 5 2 6:12 7:127:1 2 7:127:1 27:127:1 2 7 :1 2 7:12 222 3 3 2 2 2 2 9 9 9 3 3 44 4 SILL HT.4' - 0"HEAD HT.8' - 6"2 9 9 ABV. F.F.42" MIN.ABV. F.F.42" MIN.3' - 6" 12 13 11 13 11 5 5 5 5 5 55 5 12 12 14 13 33.98'33.78' 37.90' 33.04' 31.69' 31.69' 37.90' 22.13'SILL HT.3' - 0"HEAD HT.8' - 0"HEAD HT.8' - 6"SILL HT.4' - 0"HEAD HT.8' - 0"SILL HT.3' - 0"29' - 0"24' - 0"HT. CERT REQ'D HT. CERT REQ'D HT. CERT REQ'D 2' MIN.3' - 0"MAX.1' - 0"SILL HT.3' - 0"HD. HT.7' - 6"SILL HT.4' - 0"HD HT.6' - 6"12:121 2 : 1 2 33.00' 17 9' - 6"1' - 1"7' - 10"1' - 1"7' - 4"10' - 7"8' - 11"8' - 10 3/8"10 5/8"9' - 9"9' - 0"10' - 8"1' - 1"8' - 10"1' - 1"7' - 4"11' - 9"9' - 11"2' - 2"10' - 0"4SILL HT.3' - 0"7 18 17 SILL HT.4' - 8"HD. HT.8' - 2"HD. HT.8' - 6"SILL HT.5' - 0"HD. HT.8' - 0"8 HT. CERT REQ'D 1010 2020 21 16 FIRST FLOOR (T.O.S.) 9.00' FIRST FLOOR (T.O.S.) 9.00' MAX. RIDGE HEIGHT 38.00' MAX. RIDGE HEIGHT 38.00' MASTER FLOOR PLATE (TYP.) 18.50' MASTER FLOOR PLATE (TYP.) 18.50' MASTER FLOOR T.O.S. (TYP.) 19.58' MASTER FLOOR T.O.S. (TYP.) 19.58' ROOF PLATE (TYP.) 35.83' ROOF PLATE (TYP.) 35.83' NAVD 88 9.00' NAVD 88 9.00' MAX FLAT 33.00' MAX FLAT 33.00' DECK FLOOR PLATE 28.45' DECK FLOOR PLATE 28.45' DECK T.O.S.(TYP.) 29.33' DECK T.O.S.(TYP.) 29.33' 2 A-5.0 MASTER ROOF PLATE (TYP.) 28.58' MASTER ROOF PLATE (TYP.) 28.58'MAX.1' - 0"2' MIN.3' - 0"6 :1 2 6 :1 2 3 :1 2 6:12 6:12 6 5 1112 2' - 5 1/8"ABV. F.F.42" MIN.T.O.C.8' - 6"T.O.C.8' - 1"3:12 1 2 3 3 4 2 55 6 7 8 9 9 10 10 10 11 11 11 11 29' - 0"24' - 0"9' - 6"1' - 1"8' - 10 3/8"10 5/8"10' - 7"9' - 0"9' - 6"1' - 1"8' - 10 3/8"10 5/8"10' - 7"9' - 0"PLPL 37.90'37.77' 33.00' HT. CERT REQ'D HT. CERT REQ'D HT. CERT REQ'D 33 17 4 33.98' 13 16 FIRST FLOOR (T.O.S.) 9.00' FIRST FLOOR (T.O.S.) 9.00' MAX. RIDGE HEIGHT 38.00' MAX. RIDGE HEIGHT 38.00' MASTER FLOOR PLATE (TYP.) 18.50' MASTER FLOOR T.O.S. (TYP.) 19.58' ROOF PLATE (TYP.) 35.83' ROOF PLATE (TYP.) 35.83' NAVD 88 9.00' NAVD 88 9.00' MAX FLAT 33.00' MAX FLAT 33.00' THIRD FLOOR PLATE 27.42' THIRD FLOOR PLATE 27.42' THIRD FLOOR T.O.S. 28.50' THIRD FLOOR T.O.S. 28.50' DECK FLOOR PLATE 28.45' DECK T.O.S.(TYP.) 29.33' GARAGE 6.83' 1 A-5.0 3 A-5.0 SECOND FLOOR PLATE (TYP.) 17.50' SECOND FLOOR T.O.S. (TYP.) 18.58' 2 A-5.1 3 A-5.1 1' - 8"2 2 1 1 12:125:125:1 23:123:1 2 26 25 13 3226 31 22 4 23 21 4 2 3 3 3 2 3 2 2 6 :1 2 5 :1 2 5:12 55 5 5 5 5ABV. F.F.42" MIN.15 12 8 11 13 7 SILL HT.3' - 6"HEAD HT.7' - 6"ABV. F.F.42" MIN.5 16 16 33.00' 37.84'37.79'37.77'37.90' 33.00' HT. CERT REQ'D HT. CERT REQ'DHT. CERT REQ'DHT. CERT REQ'DHT. CERT REQ'D 33.98' 33.04'ABV. F.F.42" MIN.ABV. LANDING3' - 0"ABV. LANDING3' - 6"SILL HT.4' - 0"HD HT.8' - 0"29' - 0"24' - 0"29' - 0"24' - 0"7' - 4"1' - 1"8' - 10"1' - 1"10' - 8"9' - 11"11' - 9"2' - 2"7' - 4"1' - 1"7' - 10"1' - 1"9' - 6"8' - 11"10' - 7"10 5/8"8' - 10 3/8"9' - 9"17 19 12 HT. CERT REQ'D 22 FIRST FLOOR (T.O.S.) 9.00' FIRST FLOOR (T.O.S.) 9.00' MAX. RIDGE HEIGHT 38.00' MAX. RIDGE HEIGHT 38.00' ROOF PLATE (TYP.) 35.83'ROOF PLATE (TYP.) 35.83' NAVD 88 9.00' NAVD 88 9.00' MAX FLAT 33.00' MAX FLAT 33.00' THIRD FLOOR PLATE 27.42' THIRD FLOOR PLATE 27.42' THIRD FLOOR T.O.S. 28.50' THIRD FLOOR T.O.S. 28.50'1' - 1"2 A-5.0 GARAGE 6.83' GARAGE 6.83'1' - 0"SECOND FLOOR PLATE (TYP.) 17.50' SECOND FLOOR PLATE (TYP.) 17.50' SECOND FLOOR T.O.S. (TYP.) 18.58' SECOND FLOOR T.O.S. (TYP.) 18.58'10' - 8"1' - 1"8' - 10"1' - 1"7' - 4"11' - 9"9' - 11"29' - 0"24' - 0"20 19 18 27 3 212:127 :1 2 7:12 3:123:1 2 2 2 33 3 2 9 9 8 8 11 13 10 11 13 11 5 5 SILL HT.3' - 6"HEAD HT.8' - 0"6 7 33.00'33.04' 37.79'37.90' HT. CERT REQ'D HT. CERT REQ'D HT. CERT REQ'D PL PL 12 16 14 JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONSOWNER INFORMATION:PROJECT NAME STATUS These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT A-4.0 03/22/2019 2018-30EXTERIOR ELEVATIONS &MATERIAL SCHEDULEBAY FRONT TRADITIONAL BAY FRONTTRADITIONALSOUTH BAYFRONTWATERPOINTE, LLC.610 NEWPORT CENTERDRIVE, SUITE 890,NEWPORT BEACH, CA92660CDP -FIRST CHECK 400 S BAY FRONTNEWPORT BEACH, CA 92662CAITLIN SMITH KEYNOTE LEGEND 1 CONC. HARDSCAPE SLAB ON GRADE W/. FINISH PER PLANS 2 SLATE ROOFING PER MATERIAL SCHEDULE A-4.0 AND DTL 3/A-3.0. 3 WOOD BOARD AND BATTEN SIDING - REF. DTL. 5/AD-1 & MATERIAL SCHEDULE A-4 4 DECO. WD. PANELING - PAINT GRADE - COLOR AS SEL. 5 WOOD SHINGLE SIDING PER MATERIAL SCHEDULE A-4.0 AND DTL 3/A-3.0. 6 DECO. CHIMNEY SHROUD, AS SEL. (ARCH. TO APPR.) 7 CHIMNEY CAP/SPARK ARRESTOR - AS SELECTED (NOTE: DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT THE TERMINATION OF FACTORY BUILT CHIMNEYS EXCEPT WHERE SUCH SHROUDS ARE LISTED AND LABELED FOR USE WITH THE SPECIFIC FAC. BLT. CHIMNEY SYSTEM AND ARE INSTALLED IN ACCORDANCE W/. MFGR. INST. INSTRUCTIONS. CMC 802.4.2.4) 8 EXTERIOR LIGHTING - TO BE HIGH EFFICIENCY, LOW EFFICIENCY MAY BE PROVIDED PER ELECTRICAL NOTE #33 9 EXT. ADHERED STONE VENEER - REF. MATERIAL SCHEDULE SHT. A-4, DTL. 8/AD-1 10 DOWNSPOUT - METAL OR EQUIV. - AS SEL. (ARCH. TO APPROVE) 11 METAL GUTTER - KYNAR FINISH OR EQUIV., SHAPE AS SEL. - PROVIDE SHOP DWGS. TO ARCH. PRIOR TO FAB. 12 DECO. WOOD TRIM 'BELLYBAND' - PAINT GRADE, SMOOTH FINISH, ARCH. TO APPROVE PROFILE 13 ROOF FASCIA - EAVE AS DIMENSIONED (REF. ROOF PLAN & RCP FOR DETAILS) 14 DECO. WD. CORBEL - 6X8 - STAIN & SEAL AS SEL. VERIFY LOC'N. W/. ARCH. 15 MAIN SERVICE PANEL, 400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION) - VERIFY LOC'N. W/. SO. CA. EDISON 16 EXTERIOR GLASS GUARD - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTLS. 13/AD-1 17 EXTERIOR GLASS GUARD - 34" - 38" ABV. NOSING (36" TYP. U.N.O.), REF. DTL. 4 & 13/AD-1 18 CHIMNEY SHALL EXTEND AT LEAST 2' HIGHER THAN ANY PORTION OF THE BUILDING W/IN. 10', BUT SHALL NOT BE LESS THAN 3' ABV. THE HIGHEST POINT WHERE THE CHIMNEY PASSES THRU THE ROOF (CBC 2113.9) 19 STUCCO FINISH - MIN. 7/8" THK. W/. DIA. LATH, COLOR AS SEL. DEF. DTL. 5/AD-1 20 A/C. CONDENSER UNIT - SIZE TBD - PROVIDE POWER AND SOUND DAMPENING PAD AS REQ'D. (SOUND ATT. REQ'D. BY C.N.B.) SEP. PERMIT REQ'D, REF. 7/T-1 DEF. SUBMT'L. #2 21 (N.) GATE - PER LANDSCAPE DESIGNER (MAX. 5' - 6" HT. ABOVE NATURAL GRADE) 22 STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT CANDLE (CBC 1205.4) REF. DTL. 3/AD-1 MATERIAL SCHEDULEA 1/4" = 1'-0"4 LEFT SIDE ELEVATION 1/4" = 1'-0"3 FRONT ELEVATION NOTE: REF. ROOF PLAN (A-3) FOR ALL PLATE HTS. & RIDGE HTS. NOTE: FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT LABELS. NO. REVISION DATE 1/4" = 1'-0"1 RIGHT SIDE ELEVATION 1/4" = 1'-0"2 REAR ELEVATION 44 FIREBLOCKING AND DRAFTSTOPPING SHALL BE INSTALLED TO CUT OFF ALL CONCEALED DRAFT OPENINGS (BOTH VERTICAL AND HORIZONTAL) AND SHALL FORM AN EFFECTIVE BARRIER BETWEEN FLOORS, BETWEEN A TOP STORY AND A ROOF OR ATTIC SPACE, AND SHALL SUBDIVIDE ATTIC SPACES, CONCEALED ROOF SPACES AND FLOOR-CEILING ASSEMBLIES. THE INTEGRITY OF ALL FIRE BLOCKS AND DRAFT STOPS SHALL BE MAINTAINED. FIRE BLOCKS. FIREBLOCKING SHALL BE PROVIDED IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES, AT THE CEILING AND FLOOR LEVELS AND AT 10-FOOT INTERVALS BOTH VERTICAL AND HORIZONTAL. FIRE BLOCK CONSTRUCTION. FIREBLOCKING SHALL CONSIST OF 2 INCHES NOMINAL LUMBER. FIRE BLOCKS MAY ALSO BE OF GYPSUM BOARD, CEMENT FIBER BOARD, BATTS OR BLANKETS OF MINERAL OR GLASS FIBER, OR OTHER APPROVED MATERIALS INSTALLED IN SUCH A MANNER AS TO BE SECURELY RETAINED IN PLACE. LOOSE- FILL INSULATION MATERIAL SHALL NOT BE USED. WALLS HAVING PARALLEL OR STAGGERED STUDS FOR SOUND-TRANSMISSION CONTROL SHALL HAVE FIRE BLOCKS OF BATTS OR BLANKETS OF MINERAL OR GLASS FIBER OR OTHER APPROVED FLEXIBLE MATERIALS. DRAFT STOPS. DRAFTSTOPPING SHALL BE PROVIDED IN THE LOCATIONS SET FORTH IN THIS SECTION. FLOOR-CEILING ASSEMBLIES. DRAFT STOPS SHALL BE INSTALLED IN FLOOR-CEILING ASSEMBLIES OF THE BUILDING. SUCH DRAFT STOPS SHALL BE IN LINE WITH WALLS SEPARATING INDIVIDUAL DWELLING UNITS FROM EACH OTHER AND FROM OTHER AREAS. ATTICS. DRAFT STOPS SHALL BE INSTALLED IN THE ATTICS, MANSARDS, OVERHANGS, FALSE FRONTS SET OUT FROM WALLS AND SIMILAR CONCEALED SPACES OF THIS BUILDING. SUCH DRAFT STOPS SHALL BE ABOVE AND IN LINE WITH THE WALLS SEPARATING INDIVIDUAL DWELLING UNITS FROM EACH OTHER AND FROM OTHER USES. DRAFT STOP CONSTRUCTION. DRAFTSTOPPING MATERIALS SHALL NOT BE LESS THAN ½-INCH GYPSUM BOARD, 3/8-INCH WOOD STRUCTURAL PANEL, 3/8-INCH TYPE 2-M PARTICLEBOARD OR OTHER APPROVED MATERIALS ADEQUATELY SUPPORTED. OPENINGS IN THE PARTITIONS SHALL BE PROTECTED BY SELF-CLOSING DOORS WITH AUTOMATIC LATCHES CONSTRUCTED AS REQUIRED FOR THE PARTITIONS. FIRE-BLOCKING & DRAFT-STOP NOTE INSULATION SCHEDULE: EXTERIOR WALL: 2 x 4 CONST. = R-19 MIN. 2 x 6 CONST. OR LARGER =R-19 RAISED FLOOR:R-30 MIN. ROOF:R-30 (REF. T-24 REPORT FOR MORE INFORMATION) NOTE: PROVIDE BID FOR INSULATION OF ENTIRE HOME NEW WALL -2 x 6 STUDS @ 16" O.C. U.N.O. NEW WALL -2 x 4 STUDS @ 16" O.C. U.N.O. WALL W/. STONE VENEER -2x STUDS @ 16" O.C. U.N.O. CONCRETE RETAINING WALL -REF. STRUCTURAL SEPARATION LEGEND EXTERIOR FIRE RATED PARTITION REF. DTL. 5/AD-1 1 HR. FIRE RATED PARTITION REF. DTL. 7/AD-1 1 HR. FLOOR SYSTEM REF. DTL. 7/AD-1 INSULATED SYS. REF. INSULATION SCHEDULE THIS SHT. B FIRST FLOOR (T.O.S.) 9.00' FIRST FLOOR (T.O.S.) 9.00' MAX. RIDGE HEIGHT 38.00' MAX. RIDGE HEIGHT 38.00' MASTER FLOOR PLATE (TYP.) 18.50' MASTER FLOOR T.O.S. (TYP.) 19.58' ROOF PLATE (TYP.) 35.83' ROOF PLATE (TYP.) 35.83' NAVD 88 9.00' NAVD 88 9.00' MAX FLAT 33.00' MAX FLAT 33.00' THIRD FLOOR PLATE 27.42' THIRD FLOOR T.O.S. 28.50' DECK FLOOR PLATE 28.45' DECK T.O.S.(TYP.) 29.33' MASTER ROOF PLATE (TYP.) 28.58' GARAGE 6.83' GARAGE 6.83' 1 A-5.0 3 A-5.0 SECOND FLOOR PLATE (TYP.) 17.50' SECOND FLOOR T.O.S. (TYP.) 18.58' 2 A-5.1 3 A-5.1 2 2 1 1 4 23 24 25 28 2632 23 4 15 13 25 26 16 22 5 :1 2 5:12 3 :1 2 3:12 5 :1 2 5:12 29' - 0"24' - 0"8' - 6"1' - 1"8' - 10"1' - 1"7' - 4"9' - 7"9' - 11"9' - 6"1' - 1"9' - 0"7' - 3"10' - 7"8' - 10 3/8"10 5/8"3 3 3 18 18 4 4 4 4 ABV. F.F.42" MIN.R @ 0' -7 1/2"15 R @ 0' -7 5/8"15 26 26 1 1 R @ 0' -6"2 11 2 2 12 13 2714 13 28 12 19 20SLOPE PER CIVIL 2% MIN 2% MIN 2% MIN 2% MIN 2- CAR GARAGE BEDROOM #3 ROOF DECK BONUS ROOM VIEW DECK MASTER SUITE GREAT ROOM KITCHEN FOYER 9' - 9"PATIO 29 ABV. F.F.42" MIN.30 ABV. F.F.42" MIN.3131 12:12ABV. F.F.42" MIN.FIRST FLOOR (T.O.S.) 9.00' FIRST FLOOR (T.O.S.) 9.00' MAX. RIDGE HEIGHT 38.00' MAX. RIDGE HEIGHT 38.00' ROOF PLATE (TYP.) 35.83' ROOF PLATE (TYP.) 35.83' NAVD 88 9.00' NAVD 88 9.00' MAX FLAT 33.00' MAX FLAT 33.00' THIRD FLOOR PLATE 27.42' THIRD FLOOR PLATE 27.42' THIRD FLOOR T.O.S. 28.50' THIRD FLOOR T.O.S. 28.50' 2 A-5.0 1 A-5.1 SECOND FLOOR PLATE (TYP.) 17.50' SECOND FLOOR PLATE (TYP.) 17.50' SECOND FLOOR T.O.S. (TYP.) 18.58' SECOND FLOOR T.O.S. (TYP.) 18.58' PL PL 3 :1 2 3:12 7:12 27 14 20 19 5 6 10 BONUS ROOM BEDROOM #2STAIRS STAIRS FOYER POWDER R @ 0' -7 1/2"15 R @ 0' -7 5/8"15 1 R @ 0' -6"2 8' - 6"8' - 6"9' - 3 1/2"8' - 10"8' - 7 3/4"2 1 1 3 3 44 4 5 5 6 7 29' - 0"24' - 0"8' - 6"1' - 1"8' - 10"1' - 1"7' - 4"9' - 7"9' - 11"8 9 10 10 2 2ABV. F.F.42" MIN.36" TYP.34" - 38"FIRST FLOOR (T.O.S.) 9.00' FIRST FLOOR (T.O.S.) 9.00' MAX. RIDGE HEIGHT 38.00' MAX. RIDGE HEIGHT 38.00' MASTER FLOOR PLATE (TYP.) 18.50' MASTER FLOOR PLATE (TYP.) 18.50' MASTER FLOOR T.O.S. (TYP.) 19.58' MASTER FLOOR T.O.S. (TYP.) 19.58' NAVD 88 9.00' NAVD 88 9.00' MAX FLAT 33.00' MAX FLAT 33.00' DECK FLOOR PLATE 28.45' DECK FLOOR PLATE 28.45' DECK T.O.S.(TYP.) 29.33' DECK T.O.S.(TYP.) 29.33' 2 A-5.0 1 A-5.1 1' - 0"PL PL 5 6ABV. F.F.42" MIN.11 12 13 14 15 16 17 8 3 18 4 19 19 20 20 3 13 21 22 23 24 29' - 0"24' - 0"9' - 6"1' - 1"8' - 10 3/8"10 5/8"9' - 9"10' - 7"25 MASTER BATH VIEW DECK W.I.C. KITCHEN DINING ATTIC Name Elevation A101 1 SIM 101 1i ? 1 1 A101 SIM R @ 7 1/2"20 1i SECTION INDICATOR CALL-OUT TAG ELEVATION INDICATOR KEYNOTE TAG -REF. KEYNOTE LEGEND THIS SHEET WINDOW TAG -REF. SHEET A-8 DOOR TAG -REF. SHEET A-8 WALL TAG REVISION FLAG STAIR TAG (NO. OF RISER & HEIGHT) ANNOTATION LEGENDA JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONSOWNER INFORMATION:PROJECT NAME STATUS These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT A-5.0 03/22/2019 2018-30BUILDING SECTIONSBAY FRONT TRADITIONAL BAY FRONTTRADITIONALSOUTH BAYFRONTWATERPOINTE, LLC.610 NEWPORT CENTERDRIVE, SUITE 890,NEWPORT BEACH, CA92660CDP -FIRST CHECK 400 S BAY FRONTNEWPORT BEACH, CA 92662CAITLIN SMITH KEYNOTE LEGEND 1 INTERIOR HANDRAIL - 34" - 38" ABV. NOSING (36" TYP. U.N.O.), REF. DTLS. 4 & 9/AD-1 2 STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT CANDLE (CBC 1205.4) REF. DTL. 3/AD-1 3 FLOOR JOISTS - REF. STRUCT. 4 ROOF RAFTERS - REF. STRUCT. 5 SLATE ROOFING PER MATERIAL SCHEDULE A-4.0 AND DTL 3/A-3.0. 6 CHIMNEY CAP/SPARK ARRESTOR - AS SELECTED (NOTE: DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT THE TERMINATION OF FACTORY BUILT CHIMNEYS EXCEPT WHERE SUCH SHROUDS ARE LISTED AND LABELED FOR USE WITH THE SPECIFIC FAC. BLT. CHIMNEY SYSTEM AND ARE INSTALLED IN ACCORDANCE W/. MFGR. INST. INSTRUCTIONS. CMC 802.4.2.4) 7 CHIMNEY SHALL EXTEND AT LEAST 2' HIGHER THAN ANY PORTION OF THE BUILDING W/IN. 10', BUT SHALL NOT BE LESS THAN 3' ABV. THE HIGHEST POINT WHERE THE CHIMNEY PASSES THRU THE ROOF (CBC 2113.9) 8 EXTERIOR LIGHTING - TO BE HIGH EFFICIENCY, LOW EFFICIENCY MAY BE PROVIDED PER ELECTRICAL NOTE #33 9 METAL GUTTER - KYNAR FINISH OR EQUIV., SHAPE AS SEL. - PROVIDE SHOP DWGS. TO ARCH. PRIOR TO FAB. 10 DOWNSPOUT - METAL OR EQUIV. - AS SEL. (ARCH. TO APPROVE) 11 FURNISHINGS - AS SELECTED 12 BASE CABINET - BUILT-IN, FINISH AS SEL. 13 COUNTERTOP - AS SELECTED 14 KITCHEN SINK - AS SELECTED 15 CUSTOM BUILT KITCHEN ISLAND PER OWNER & ARCH. 16 KITCHEN EXHAUST HOOD - PROVIDE MIN. RATE OF 100 CFM - INSTALL & PROVIDE POWER PER MFGR'S. INSTRS. 17 DOUBLE OVEN - AS SELECTED 18 DECK FRAMING - REF. STRUCT. 19 (N.) CONCRETE SLAB ON GRADE - REF. STRUCT. & CIVIL DWGS. 20 CONCRETE FOOTING - REF. STRUCTURAL 21 SINK - AS SELECTED (VERIFY COUNTER OR WALL MOUNT FIXTURES W/. OWNER) 22 BASE CABINET - SINK UNIT, BUILT-IN, FINISH AS SEL. 23 BATHTUB - AS SELECTED (VERIFY LOC'N. OF FIXTURES W/. OWNER) 24 SHELF AND POLE - BUILT IN, FINISH AS SEL. 25 INTERIOR GLASS GUARD - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTLS. 4 & 18/AD-1 26 INTERIOR GUARD - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTLS. 4 & 9/AD-1 27 UPPER CABINET - BUILT-IN, FINISH AS SEL. 28 LAUNDRY SINK - AS SEL. 29 EXTERIOR GLASS GUARD - 34" - 38" ABV. NOSING (36" TYP. U.N.O.), REF. DTL. 4 & 13/AD-1 30 LINE OF TRELLIS ABV. 31 EXTERIOR GLASS GUARD - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTLS. 13/AD-1 1/4" = 1'-0"2 LONGITUDINAL SECTION 1/4" = 1'-0"1 TRANSVERSE SECTION 1/4" = 1'-0"3 TRANSVERSE SECTION NO. REVISION DATE 45 FOUNDATION NOTES:ALL DIMENSIONS SHALL BE VERIFIED WITH THE ARCHITECTS DRAWINGS ANY DISCREPANCIES SHALL BE RESOLVED PRIOR TO COMMENCING OF WORK. 1. ALL BEARING & SHEAR WALLS ARE TO BE SECURED WITH 5/8" DIAMETER BY 10" LONG ANCHOR BOLTS EMBEDDED AT LEAST 7" INTO CONCRETE WITH A MAXIMUM SPACING OF 48" O.C. U.N.O. THERE SHALL BE A MINIMUM OF TWO ANCHORS PER PIECE OF FOUNDATION PLATE WITH ONE BOLT LOCATED WITHIN 12" MAX. & 4-1/2" MIN. OF EA. END OF EA. PIECE. SHEAR WALLS BOLTS SHALL HAVE A PROPERLY SIZED NUT AND A 3"x3"x.229" WASHER. THE WASHER MAY BE SLOT CUT PROVIDED A STANDARD CUT WASHER IS PROVIDE BETWEEN THE NUT AND WASHER. WASHER TO BE INSTALLED WITHIN A 1/2" OF THE SHEATHED SIDE OF THE PLATE. A STANDARD CUT WASHER MAY BE USED AT NON-SHEAR WALL LOCATIONS. 2. FOR ALL INTERIOR NON-SHEAR WALLS USE SIMPSON 0.145" DIAMETERx 3" LONG PDP POWDER ACTUATED ANCHORS @ 24" O.C. (ESR #2138 OR EQUAL)3. INSTALL ALL SIMPSON (OR APPROVED EQUAL) FOUNDATION HARDWARE PER MANUFACTURERS RECOMMENDATIONS. DEEPEN FOOTING WHERE NECESSARY TO PROVIDE ANCHOR EMBEDMENT AT HOLDOWN LOCATIONS. 4. ALL WOOD BEARING ON CONCRETE OR MASONRY SHALL BE PRESSURE TREATED DOUG FIR OR REDWOOD WITH SODIUM BORATE (SBX) OR DISODIUM OCTABORATE TETRAHYDRATE (DOT).NOTE:WHEN REQUIRED BY LOCAL BUILDING DEPARTMENT ALL ANCHOR BOLTS AND HOLDOWN BOLTS TO BE SET IN PLACE PRIOR TO CITY FOUNDATION INSPECTIONSOIL INFORMATION:1. FOUNDATION SIZES, DEPTHS, AND REINFORCEMENT ARE AS RECOMMENDED WITHIN THE OWNER/DEVELOPER'S SOILS ENGINEERS REPORT. SOILS ENGINEER TO PROVIDE FOUNDATION INSPECTOR AS OUTLINED IN LATEST SOIL REPORT. 2. OWNER/DEVELOPER AND SUBCONTRACTORS ARE TO REVIEW THE SOILS REPORT PRIOR TO COMMENCING CONSTRUCTION. IT IS THE RESPONSIBILITY OF THE OWNER, DEVELOPER AND SUBCONTRACTOR TO VERIFY THAT THE REPORT DATE ABOVE IS CURRENT AND PLAN REQUIREMENTS ARE CONSISTANT WITH ANY UPDATED SOIL REPORTS. ESI/FME IS TO BE SUPPLIED WITH ALL UPDATED REPORTS.15" WIDE x 24" DEEP FTG.W/ 2-#5 TOP & BOTTOM CONT.ANCHOR BOLT LEGEND:SLAB: 5" THK. W/#4 BARS @ 12" O/C E/W @ MIDDLE NEW CONSTRUCTION WITH SLAB ON GRADE SHALL INSTALL A CAPILLARY BREAK IN COMPLIANCE WITH CG 4.505.2.1 WITH 2-INCH THICK LAYER OF SAND OVER A 15 MIL VAPOR BARRIER COMPLIANT WITH ASTM E 1745 OVER A 4-INCH THICK BASE OF 1/2-INCH OR LARGER CLEAN AGGREGATE AND A CONCRETE MIX DESIGN WHICH WILL ADDRESS BLEEDING, SHRINKAGE, AND CURLING. (FOR ADDITIONAL INFORMATION, SEE AMERICAN CONCRETE INSTITUTE, ACI 302.OR-06)AB48 : 5/8" DIA. X 12" ANCHOR BOLTS AT 48" O.C. AB40 : 5/8" DIA. X 12" ANCHOR BOLTS AT 40" O.C. AB32 : 5/8" DIA. X 12" ANCHOR BOLTS AT 32" O.C. AB24 : 5/8" DIA. X 12" ANCHOR BOLTS AT 24" O.C. AB16 : 5/8" DIA. X 12" ANCHOR BOLTS AT 16" O.C. AB 8 : 5/8" DIA. X 12" ANCHOR BOLTS AT 8" O.C. 2AB : (2) 5/8" DIA X 12" ANCHOR BOLTS. 3AB : (3) 5/8" DIA. x 12" ANCHOR BOLTS. 2-#4 : PROVIDE A TOTAL OF 2 #4 AT TOP AND 2 #4 AT BOTTOM OF FOOTING, 3' PAST POSTS. 3-#4 : PROVIDE A TOTAL OF 3 #4 AT TOP AND 3 #4 AT BOTTOM OF FOOTING, 3' PAST POSTS. HTT4 : (1) SIMPSON HTT4 PER POST. HTT5 : (1) SIMPSON HTT5 PER POST. HDU2 : (1) SIMPSON HDU2-SDS2.5 PER POST. HDU5 : (1) SIMPSON HDU5-SDS2.5 PER POST. HDU8 : (1) SIMPSON HDU8-SDS2.5 PER POST. HDQ8 : (1) SIMPSON HDQ8-SDS3 PER POST. HDU11 : (1) SIMPSON HDU11-SDS2.5 PER POST. HDU14 : (1) SIMPSON HDU14-SDS2.5 PER POSTGRADE BEAM PER PLANWIDEN AT HARDY FRAME AS REQUIREDSEE SHEET 'HFX1' FOR SHEAR TIE SPACINGLATERAL SHEAR NOTES:(2016 CBC, SDPWS-2015 ; SEISMIC DESIGN CATEGORY D & E) (TABLE 4.3A, AFPA SDPWS-2015) FRAMING MEMBERS VERTICAL: DOUGLAS FIR-LARCH AT 16" O.C10. 1/2" WOOD STRUCTURAL PANEL WITH 8d COMMON NAILS AT 6" O.C AT EDGES AND 12" O.C. AT FIELD . .....260 PLF11. 1/2" WOOD STRUCTURAL PANEL WITH 8d COMMON NAILS AT 4" O.C AT EDGES AND 12" O.C. AT FIELD ......350 PLF12. 1/2" WOOD STRUCTURAL PANEL WITH 8d COMMON NAILS AT 3" O.C AT EDGES AND 12" O.C. AT FIELD ......490 PLF13. 1/2" WOOD STRUCTURAL PANEL WITH 8d COMMON NAILS AT 2" O.C AT EDGES AND 12" O.C. AT FIELD ......640 PLF14. 1/2" (OR 15/32) WOOD STRUCTURAL PANEL WITH 10d COMMON NAILS AT 2" O.C AT EDGES AND 12" O.C. AT FIELD ......770 PLF15. 1/2" (OR 15/32) STRUCT. I WOOD PANEL WITH 10d COMMON NAILS AT 2" O.C AT EDGES AND 12" O.C. AT FIELD ......870 PLF# FRAMING MEMBERS HORIZONTAL: DOUGLAS FIR-LARCH (3/8" @ CEILING LDS, 15/32 @ ROOF SHEATHING: AT 24" O.C20. BLOCKED PLYWOOD DIAPHRAGM WITH 3/8" WOOD STRUCTURAL PANEL AND 8d COMMON NAILS AT 6" O.C. AT BOUNDRIES, 6" AT CENTER AND 10" AT FIELD .....240 PLF21. BLOCKED PLYWOOD DIAPHRAGM WITH 3/8" WOOD STRUCTURAL PANEL AND 8d COMMON NAILS AT 4" O.C. AT BOUNDRIES, 6" AT CENTER AND 10" AT FIELD .....320 PLF22. BLOCKED PLYWOOD DIAPHRAGM WITH 3/8" WOOD STRUCTURAL PANEL AND 8d COMMON NAILS AT 2.5" O.C. STAGG.AT BOUNDRIES, 4" AT CENTER AND 10" AT FIELD .....480 PLF23. BLOCKED PLYWOOD DIAPHRAGM WITH 3/8" WOOD STRUCTURAL PANEL AND 8d COMMON NAILS AT 2" O.C. STAGG.AT BOUNDRIES, 3" AT CENTER AND 10" AT FIELD .....545 PLF# FRAMING MEMBERS HORIZONTAL: DOUGLAS FIR-LARCH AT 16" O.C24. BLOCKED PLYWOOD DIAPHRAGM WITH 19/32" WOOD STRUCTURAL PANEL AND 10d COMMON NAILS AT 6" O.C. AT BOUNDRIES, 6" AT EDGES AND 10" AT FIELD .....320 PLF25. BLOCKED PLYWOOD DIAPHRAGM WITH 19/32" WOOD STRUCTURAL PANEL AND 10d COMMON NAILS AT 4" O.C. AT BOUNDRIES, 6" AT EDGES AND 10" AT FIELD .....425 PLF26. BLOCKED PLYWOOD DIAPHRAGM WITH 19/32" WOOD STRUCTURAL PANEL AND 10d COMMON NAILS AT 2.5" O.C. STAGG. AT BOUNDRIES, 6" AT EDGES AND 10" AT FIELD .....640 PLF27. BLOCKED PLYWOOD DIAPHRAGM WITH 19/32" WOOD STRUCTURAL PANEL AND 10d COMMON NAILS AT 2" O.C. STAGG. AT BOUNDRIES, 3" AT EDGES AND 10" AT FIELD .....730 PLF#NOTES:A. WOOD STRUCTURAL PANEL: MATERIAL APPROVED BY APA, PFS/TECO OR PITTSBURG TESTING LABORATORIES THESE VALUES ARE FOR DOUG-FIR LARCH OR SOUTHERN PINE, OTHER LUMBER SPECIES MAY DIFFER IN SHEAR CAPACITIES. B. PROVIDE 2X BLOCKING AT HORIZONTAL WOOD STRUCTURAL PANEL JOINTS. FRAMING AT ADJOINING PANEL EDGES SHALL BE 3X WHEN NAILING IS 2.5" O.C. OR LESS. C. WHERE WOOD STRUCTURAL PANEL IS APPLIED ON BOTH FACES OF WALL AND NAIL SPACING IS LESS THAN 6" O.C, PANEL JOINTS SHALL BE OFFSET TO FALL ON DIFFERENT FRAMING MEMBERS OR FRAMING SHALL BE 3X OR WIDER AND NAILS STAGGERED ON EACH SIDE. D. FOR SHEAR WALLS TO USE THE FOLLOWING: 1) USE 3x MEMBER @ PANEL JOINTS & HORIZONTAL BLOCKING 2) EDGE NAILING SHALL BE STAGGERED E. 10d SHORT BOX NAILS MAY BE USED IN LIEU OF 8d COMMON NAILS @ SHEAR WALLS ONLY. F. REQUIRED STEEL PLATE WASHERS AT SHEAR WALLS ONLY (WHEN ANCHOR BOLTS ARE USED: 3" x 3" x .229" STEEL PLATE WASHERS ARE REQUIRED ON EACH ANCHOR BOLT (SDPWS SECT. 4.3.6.4.3) WASHER MAY BE SLOT CUT PROVIDED A STANDARD CUT WASHER IS PROVIDED BETWEEN THE WASHER AND NUT. WASHER TO BE INSTALLED WITHIN 1/2" OF SHEATHED SIDE OF PLATE. G. A STANDARD CUT WASHER MAY BE USED AT ALL NON-SHEAR WALL LOCATIONS WITH ANCHOR BOLTS. 1215HORIZONTAL: ALL ROOF AND FLOOR SHEATHING TO BE EXPOSURE I OR EXTERIOR ROOF: -JOIST SPACING EQUAL TO OR LESS THAN 24" O.C: 15/32"WOOD STRUCTURAL PANEL PII 32/16, WITH 8d's AT 6" O.C AT EDGES AND BOUNDARIES, 12" O.C FIELD. -HORIZONTAL DIAPHRAGM VALUES FOR 3/8" WOOD STRUCTURAL PANELS MAY BE USED FOR 15/32" WOOD STRUCTURAL PANELS. U.N.O. FLOOR: - JOIST SPACING EQUAL TO OR LESS THAN 16" O.C: 19/32" WOOD STRUCTURAL PANEL T&G SHTG, PII 32/16, w/10d's AT 6" O.C AT EDGES AND BOUNDARIES, 12" O.C FIELD. -JOIST SPACING EQUAL TO OR LESS THAN 20" O.C: 19/32" WOOD STRUCTURAL PANEL T&G SHTG, PII 40/20, w/10d's AT 6" O.C AT EDGES AND BOUNDARIES, 12" O.C FIELD. -JOIST SPACING EQUAL TO OR LESS THAN 24" O.C: 23/32" WOOD STRUCTURAL PANEL T&G SHTG, PII 48/24, w/10d's AT 6" O.C AT EDGES AND BOUNDARIES, 12" O.C FIELD. PANEL EDGES SHALL HAVE APPROVED T&G JOINTS OR SHALL BE SUPPORTED WITH * BLOCKING NOT REQUIRED WHEN LIGHTWEIGHT CONCRETE IS PLACED OVER SUBFLOOR.FRAMING LEGEND:INDICATES SPAN AND DIRECTION OFDECK JOISTS (SLOPED AS REQUIRED)ROOF JOISTS AND RAFTERSINDICATES SPAN AND DIRECTION OFFLOOR JOISTSINDICATES SPAN AND DIRECTION OFCEILING JOISTSINDICATES SPAN AND DIRECTION OFTRUSSESA. 2x6 AT 12" O.C B. 2x6 AT 16" O.C C. 2x6 AT 24" O.C D. 2x8 AT 12" O.C E. 2x8 AT 16" O.C F. 2x8 AT 24" O.C G. 2x10 AT 12" O.C H. 2x10 AT 16" O.C J. 2x10 AT 24" O.C K. (2) 2x10 AT 16" O.C L. 2x12 AT 12" O.C M. 2x12 AT 16" O.C N. 2x12 AT 24" O.C P. (2) 2X12 AT 16" O.CT. TRUSS AT 24" O.CI-JOIST TABLER-I-JOIST @ 16" O.C.I-JOIST @ 12" O.C.I-JOIST @ 19.2" O.C.I-JOIST @ 16" O.C.Z-X-Y-I-JOIST @ 19.2" O.C.I-JOIST @ 16" O.C.I-JOIST @ 12" O.C.I-JOIST @ 19.2" O.C.V-W-S-U-SIZE &MANUFACTURER OPTIONSSPACINGI-JOIST @ 12" O.C.MARKQ-a) 9 1/2" TJI / 230a) 11 7/8" TJI / 360a) 14" TJI / 360##G=L - INDICATES (1) GANGLAM LVL 1.8EGLB - INDICATES GLULAM BEAMM=L - INDICATES (1) MICROLAM 2.0EPSL - INDICATES PARALAM 2.0ELSL - INDICATES TIMBERSTRAND 1.55EE/S - EACH SIDEFL. HT. - FULL HEIGHTALT. - ALTERNATETYP. - TYPICALU.W.A. - UNDER WALL ABOVEL.O.B. - INDICATES LINE OF BLOCKING R.T.R. - RUN TO ROOF'U' - INDICATES 'U' HANGER, U.N.O. - INDICATES 'HU' HANGER, U.N.O. - INDICATES HEADERS AND BEAMS, REFER TO ENGINEERING CALCSNOTE: * APPLY SHEAR PRIOR TO FRAMING OF PERPENDICULAR WALL AND/OR BOX-OUTS. (WHERE APPLICABLE)FRAMING NOTES LEGENDMARK: DESCRIPTIONSPN12: 16d SOLE PLATE NAILING @ 12" O.C.SPN10: 16d SOLE PLATE NAILING @ 10" O.C.SPN8: 16d SOLE PLATE NAILING @ 8" O.C.SPN4: 16d SOLE PLATE NAILING @ 4" O.C.SPN6: 16d SOLE PLATE NAILING @ 6" O.C.SPN3: 16d SOLE PLATE NAILING @ 3" O.C. STAGGEREDSPN2: 16d SOLE PLATE NAILING @ 2" O.C. STAGGEREDSPN=SOLE PLATE NAILINGNAILS= 16d BOXXX - INDICATES LATERAL ENHANCEMENT. WALL NOT CONSIDERED IN LATERAL ANALYSIS. - SHEAR WALL GRID LINE, REFERENCE STRUCTURAL CALCS FASTENERS AND CONNECTORS TO BE GALVANIZED FOR PRESERVATIVE PRESSURE TREATED WOOD.#GREAT ROOMLOUNGEKITCHENDININGELEV.FOYERSTAIRSC.C.POWDER2- CAR GARAGEENTRYPATIOSCALE: 1/4" = 1'-0"FOUNDATION PLANA1FD1P115" WIDE x 24" DEEPGRADE BEAMW/ (2) #5 TOP & BOTTOM1' - 10"MIN.11"MIN.11"2' - 6"1' - 9".1' - 9"2' - 6"1' - 10"MIN.11"MIN.11"1FD1A1' - 10"MIN.11"MIN.11"1' - 2 23/32".1' - 9"1' - 10"MIN.11"MIN.11"15" WIDE x 24" DEEPGRADE BEAMW/ (2) #5 TOP & BOTTOM3' - 0 9/32"2' - 6"2FD1A.A.1FD1.P1.10FD15FD11FD11FD12FD11FD15FD15FD14FD14FD13FD13FD12FD1P2.B.2' - 6"2' - 6"1' - 9"15" WIDE x 24" DEEPGRADE BEAMW/ (2) #5 TOP & BOTTOM1' - 10"MIN.11"MIN.11"GREAT ROOMLOUNGEKITCHENDININGELEV.FOYERSTAIRSC.C.POWDER2- CAR GARAGEENTRYPATIOSCALE: 1/4" = 1'-0"FIRST FLOOR FRAMING PLANPAD FOOTING SCHEDULEPAD #PAD SIZE AND REINFORCINGP1P248"x 72"x RECT. x 24" DEEP CONCRETE PADW/ (3) #5 EACH WAY, @ BOTTOM30" SQ. x 40" DEEP CONCRETE PADW/ #5 @ 12" O.C., EACH WAY, @ BOTTOMNOTES:- CENTER PADS ON POSTS, U.N.O.- BOTTOM OF PAD TO MATCH BOTTOM OF FOOTING.- RUN FOOTING REINFORCING CONTIUOUS THROUGH PADS.FAX: 714-835-2819PHONE: 714-835-2800STRUCTURAL ENGINEERS,INC.ESI/FMESANTA ANA, CA 927011800 E. 16TH ST. STE BJOB NO.DATEDOCUMENT VALID UPONORIGINAL SIGNATURESHEET NO.REVISIONSOWNER INFORMATION:PROJECT NAMESTATUSS1K046FOUNDATION PLANBAY FRONT PLACEBAY FRONT PLACEGARRETT CALACCI610 NEWPORT CENTERDRIVE, SUITE 890,NEWPORT BEACH, CA92660FIRST SUBMITTAL400 S BAY FRONTNEWPORT BEACH, CA 9266202-28-2019JOB #K04602-28-19NO. DESCRIPTION DATE46 Name Elevation A101 1 SIM Room name 150 SF 101 1i ? 90 00' 00" Distance N E 1 1 A101 SIM R @ 7 1/2"20 1i NORTH ARROW PROPERTY LINE TAG SECTION INDICATOR ROOM TAG (NAME / AREA) CALL-OUT TAG ELEVATION INDICATOR KEYNOTE TAG WINDOW TAG DOOR TAG WALL TAG REVISION FLAG STAIR TAG (NO. OF RISER & HEIGHT) ALUMINUM CONCRETE EARTH GYPSUM -PLASTER INSULATION -RIGID MASONRY -BRICK/STONE MASONRY -CONCRETE BLOCK PLYWOOD / GLU-LAM TIMBER SAND STEEL WOOD JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONSOWNER INFORMATION:PROJECT NAME STATUS These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT T-1.0 05/08/2019 2018-30TITLE SHEETMODERN BAY FRONT MODERN BAY FRONTSOUTH BAYFRONTWATERPOINTE, LLCGARRETT CALACCI610 NEWPORT CENTERDRIVE, SUITE 890,NEWPORT BEACH, CA92660FIRST CHECK 402 S BAY FRONTNEWPORT BEACH, CA 92662CAITLIN SMITH JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONSOWNER INFORMATION:PROJECT NAME STATUS These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT T-1.0 05/08/2019 2018-30TITLE SHEETMODERN BAY FRONT MODERN BAY FRONTSOUTH BAYFRONTWATERPOINTE, LLCGARRETT CALACCI610 NEWPORT CENTERDRIVE, SUITE 890,NEWPORT BEACH, CA92660FIRST CHECK 402 S BAY FRONTNEWPORT BEACH, CA 92662CAITLIN SMITH REF. 8/T-1.0FLOOR AREA HEIGHT NBMC (NEWPORT BEACH MUNICIPAL CODE) CALIFORNIA CODES: 2016 CBC, 2016 CFC, 2016 CEC, 2016 CPC, AND 2016 CMC, 2016 CAL GREEN R-3 / U 1-HR. CODES: OCCUPANCY CLASSIFICATION OCCUPANCY SEPARATIONS (GARAGE) OCCUPANT LOAD TYPE OF CONSTRUCTION OWNER: ARCHITECT: N/AALLOWABLE BLDG. AREA (PER CBC TBL. 503) FLOOR & FLOOR-CEILINGS N/A BRANDON ARCHITECTS, INC. CHRISTOPHER BRANDON 151 KALMUS DR. STE. G-1 COSTA MESA, CA 92626 P: 714.754.4040 WWW.BRANDONARCHITECTS.COM STRUCTURAL ENGINEER:CIVIL ENGINEER: GENERAL CONTRACTOR:LANDSCAPE DESIGNER: SURVEYOR:SOILS ENGINEER: SITE 1 UNIT V-B -SPRK'R. 3 STORY FIRE SPRINKLER: NFPA 13D YES DEFERRED SUBMITTALS 8PROJECT STATISTICS 5 3 1 249 10 AGENCIES & PUBLIC SERVICES VICINITY MAP/ PROJECT DESCRIPTION MATERIAL LEGEND ANNOTATION LEGEND CODE REVIEW SHEET LISTSITE INFORMATION11 7 6SPECIAL INSPECTIONS PROJECT DIRECTORYPROJECT DIRECTORY PROJECT DESCRIPTION: MODERN BAY FRONT BRANDON ARCHITECTS, INC.TBD BUILDING AREA SCHEDULE Name AREA COMMENTS FIRST FLOOR 1005 SF SECOND FLOOR 1362 SF THIRD FLOOR 291 SF 2659 SF 2-CAR GARAGE 450 SF 450 SF GRAND TOTAL 3108 SF OUTDOOR AREA SCHEDULE NAME AREA COMMENTS PATIO 175 SF PARTIALLY COVERED L1 73 SF UNCOVERED OPEN SPACE 1 282 SF COVERED OPEN SPACE 2 123 SF PARTIALLY COVERED 654 SF ROOF DECK 606 SF UNCOVERED VIEW DECK 491 SF UNCOVERED 1098 SF GRAND TOTAL 1751 SF SHEET #DRAWING TITLE T-1.0 TITLE SHEET T-1.1 GENERAL ARCHITECTURAL NOTES T-1.2 SUPPLEMENTAL NOTES & DOCUMENTS SUR TOPOGRAPHIC SURVEY A-0.0 ARCHITECTURAL SITE PLAN A-0.1 BUILDING AREA PLANS G-02 PRECISE GRADING PLAN G-04 EROSION CONTROL PLAN A-1.0 3-DIMENSIONAL VIEWS A-2.0 FLOOR PLANS A-3.0 ROOF PLAN A-4.0 EXTERIOR ELEVATIONS & MATERIAL SCHEDULE A-5.0 BUILDING SECTIONS S1 FOUNDATION PLAN FD1 FOUNDATION DETAILS INTERIOR DESIGNER: TBD DIG ALERT: 1.800.227.2600 SOUTHERN CALIFORNIA EDISON: 1.714.895.0246 SOUTHERN CALIFORNIA GAS: 1.800.427.2000 CITY WATER & SEWER: 1.949.644.3011 PACIFIC BELL TELEPHONE: 1.800.750.2355 CITY OF NEWPORT BEACH PUBLIC WORKS DEPT.: 1.949.644.3311 CITY OF NEWPORT BEACH PLANNING DEPT.: GENERAL INFOMATION: 1.949.644.3200 ZONING INFORMATION:1.949.644.3204 CITY OF NEWPORT BEACH BUILDING DEPT.: GENERAL:1.949.644.3275 PERMITS:1.949.644.3288 INSPECTIONS:1.949.644.3255 NEWPORT BEACH FIRE DEPARTMENT:1.949.644.3106 ORANGE COUNTY HEALTH SERVICES:1.714.834.3882 NOTE: DEFERRED SUBMITTALS TO BE REVIEWED BY PROJECT ARCHITECT OR ENGINEER OF RECORD AND CERTIFIED PRIOR TO SUBMITTAL TO LOCAL AGENCY FOR REVIEW. C.N.B. NOTE:CHRISTOPHER BRANDON, PRINCIPAL ARCHITECT IS THE DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE OF THE PROJECT, RESPONSIBLE FOR REVIEWING AND COORDINATING SUBMITTAL DOCUMENTS PREPARED BY OTHERS, INCLUDING PHASED AND DEFERRED SUBMITTAL ITEMS, FOR COMPATIBILITY WITH THE DESIGN OF THE BUILDING. (NBMC 15.02.010) 1.LANDSCAPE PLAN; BBQ; FIRE PIT; ACCESSORY STRUCTURES, MASONRY OR CONCRETE WALLS/FENCES; RETAINING WALLS OVER 4 FT. HIGH FROM THE BOTTOM OF THE FOUNDATION TO THE TOP OF WALL; UNDER SEPERATE SUBMITTAL (FOR H.O.A. PURPOSES). 2. POOLS, SPAS, WALLS, FENCES, PATIO COVERS AND OTHER FREESTANDING STRUCTURES REQUIRE SEPARATE REVIEWS AND PERMITS. 3. SUBMIT SOUND ATTENUATION DESIGN FOR HVAC EQUIPMENT PER ARI STD. 275. SOUND LEVEL NOT TO EXCEED 50dBA (55dBA WITH TIMER, 65dBA WITH TIMER AND NEIGHBORS CONSENT). LOCATION OF MEASUREMENT TO BE AT ADJACENT PROPERTY PATIO OR OPENING. 4. A CAL-OSHA PERMIT IS REQUIRED FOR EXCAVATIONS DEEPER THAN 5' AND FOR SHORING AND UNDERPINNING. CONTRACTOR TO PROVIDE A COPY OF OSHA PERMIT. 5. FIRE SPRINKLERS REQUIRED, CONSTRACTOR TO SUBMIT FIRE SPRINKLER DRAWINGS FOR ARCHITECT'S APPROVAL PRIOR TO SUBMITTING TO CITY. OBTAIN FIRE SPRINKLER PERMIT PRIOR TO CALLING FOR ROOF SHEATHING INSPECTION. 6. GLASS GUARD/HANDRAILS 1. REF. STRUCT. SHTS. FOR SPECIAL INSPECTION BY ENGINEER OF RECORD 2. HERS VERIFICATION REQUIRED, REF. T-24 ENERGY CALCULATIONS LEGAL DESCRIPTION: LOT INFORMATION: EXISTING BUILDING INFORMATION: EXISTING MULTI FAMILY W/ GARAGE TO BE DEMOLISHED EXISTING S.F. = 1,842.37 S.F. (FOOTPRINT) ZONING INFORMATION: 402 S. BAY FRONT, NEWPORT BEACH, CA 92662 NO. REVISION DATENO. REVISION DATE TITLE 24 CONSULTANT: TBD ZONED: R-B1 SITE AREA:2630 S.F. BUILDABLE AREA: 1992 S.F. TOTAL ALLOWABLE AREA: 1.5 x 1992 S.F. = 2988 S.F. +200 S.F. = 3188 S.F. REQ'D OPEN VOLUME = 1992 S.F. X .15 = 298.8 S.F. (7'-6" HT MIN.) OPEN VOLUME PROVIDED= 654 S.F. > 298.8 S.F. FRONT SETBACK: 0 FT. REAR SETBACK: 5 FT. LEFT SETBACK: 3 FT. RIGHT SETBACK: 3 FT. THE SUBJECT PROPERTY IS LOCATED IN NEWPORT BEACH, CA ON BALBOA ISLAND ON SOUTH BAY FRONT WEST OF THE FERRY TERMINAL. THE EXISTING LOT IS APPROX. 30' WIDE BY APPRX. 86' DEEP AND ZONED R- BI (BALBOA ISLAND) AND APPROX. 2,591.66 S.F.. THE CLIENT PROPOSES TO BUILD A NEW 3-STORY SINGLE FAMILY RESIDENCE APPROX. 2,655 S.F. LIVING AND 450 S.F. GARAGE TO BE WOOD FRAMED WITH A CONCRETE FOUNDATION. THE PROJECT WILL BE OF A SOFT CONTEMPORARY DESIGN, INCLUDING BUT NOT LIMITED TO THE FOLLOWING: AMPLE INDOOR/OUTDOOR LIVING SPACES INTEGRATED WITH A MODERN ‘OPEN’LIVING FLOOR PLAN WHICH MAXIMIZES LIGHT AND VIEWS FROM LIVING SPACES AS WELL AS OUTDOOR PATIOS, AND DECKS. AMPLE PARKING WILL BE PROVIDED IN THE FORM OF A 2-CAR GARAGE WITH ACCESS OFF OF S. BAY FRONT ALLEY. THE EXTERIOR WILL BE PRIMARILY SMOOTH STUCCO AND BRICK VENEER, WITH NATURAL WOOD AND METAL ELEMENTS. THE HOME WILL HAVE APPROXIMATELY 3 BEDROOM SUITES, AND 4 BATHS. OUTDOOR LIVING WILL BE PROVIDED IN THE FORM OF PATIOS, BALCONIES AND DECKS. SOUTH BAYFRONT WATERPOINTE, LLC. MR. GARRETT CALACCI, PRESIDENT 610 NEWPORT CENTER DR. SUITE 890 NEWPORT BEACH, CA 92660 P: 949.644.8900 WATERPOINTE PROPERTIES, LLC MR. GARRETT CALACCI, PRESIDENT 610 NEWPORT CENTER DR. SUITE 890 NEWPORT BEACH, CA 92660 P: 949.644.8900 APEX LAND SURVEYING, INC. PAUL CRAFT, LIC. NO. 8516 HUNTINGTON BEACH, CA 92646 P: 714.488.5006 F: 714.333.4440 FARHAD MANSHADI, LIC. NO. C36840 ESI/FME, INC. 1800 E. 16TH ST., STE. B SANTA ANA, CA 92701 P: 714.835.2800 F: 714.835.2819 EGA CONSULTANTS, LLC. 375-C MONTE VISTA AVE. COSTA MESA, CA 92627 P.949.642.9303 FORKETT ENGINEERING TOM RUIZ P: 714 963 6793 22311 BROOKHURST ST. HUNTINGTON BEACH, CA 92646 APN: 050-043-13 LOT 2 BLOCK 7 OF SECTION 1, BALBOA ISLAND, IN THE CITY OF NEWPORT BEACH, COUNTY OF ORANGE, STATE OF CALIFORNIA,AS PER MAP RECORDED IN BOOK 6, PAGE 30 OF MISCELLANEOUS MAPS, RECORDS OF ORANGE COUNTY, CALIFORNIA. TOTAL LIVING TOTAL GARAGE TOTAL OPEN SPACE TOTAL OUTDOORS BAY FRONTMARINE AVETOTAL ROOF DECK 47 JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONSOWNER INFORMATION:PROJECT NAME STATUS These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT T-1.1 03/22/2019 2018-30GENERAL ARCHITECTURAL NOTESMODERN BAY FRONT MODERN BAY FRONTSOUTH BAYFRONTWATERPOINTE, LLCGARRETT CALACCI610 NEWPORT CENTERDRIVE, SUITE 890,NEWPORT BEACH, CA92660CDP -FIRST CHECK 402 S BAY FRONTNEWPORT BEACH, CA 92662Designer 1GENERAL NOTES ABBREVIATIONS 2 DEFINITIONS: SPECIFICATIONS SHALL MEAN: WRITTEN SPECIFICATIONS IN THE PLANS OR THE "PROJECT MANUAL" (IF PROVIDED FOR THIS PROJECT) CONTRACT DOCUMENTS SHALL MEAN: WORKING DRAWINGS APPROVED FOR BUILDING PERMIT, PLUS ANY CHANGE ORDERS OR ADDENDA TO SAME. CONTRACTOR SHALL MEAN: SOUTH BAYFRONT WATERPOINTE, LLC. ARCHITECT SHALL MEAN: BRANDON ARCHITECTS, INC., CHRISTOPHER BRANDON PRINCIPAL OWNER SHALL MEAN: (AS USED IN THESE SPECIFICATIONS) LICENSED GENERAL CONTRACTOR HIRED TO PERFORM THE WORK UNDER THIS CONTRACT 1. CODES/GENERAL PROVISIONS: ALL WORK, CONSTRUCTION AND MATERIALS SHALL COMPLY WITH ALL PROVISIONS OF THE APPLICIABLE BUILDING CODES AND WITH OTHER RULES, REGULATIONS AND ORDINANCES GOVERNING THE PLACE OF CONSTRUCTION. IT IS THE RESPONSIBILITY OF THE CONTRACTOR, SUB-CONTRACTORS, AND ANYONE SUPPLYING LABOR AND/OR MATERIAL TO BRING TO THE ATTENTION OF THE ARCHITECT (VERBALLY AND IN WRITING) ANY KNOWN DISCREPANCIES OR CONFLICT BETWEEN THE REQUIREMENTS OF THESE CODES AND THE CONTRACT DOCUMENTS (DRAWINGS). THE APPLICABLE CODES SHALL INCLUDE, BUT SHALL NOT BE LIMITED TO THOSE AS LISTED IN "CODE REVIEW" BOX. (T-1) ALL WORK SHALL BE PERFORMED SO AS TO COMPLY WITH ALL LEGAL AND INDUSTRY REQUIREMENTS AND STANDARDS INCLUDING THE FOLLOWING: THE BUILDING CODES, 2016 EDITIONS, AS ADOPTED BY CALIFORNIA, ALL APPLICABLE RELATED SPECIALTY CODES. THE FUNCTIONALITY STANDARDS SET FORTH IN TITLE 7 OF THE CALIFORNIA CIVIL CODE (THE "RIGHT TO REPAIR ACT"). ANY WORK TIME RESTRICTIONS IMPOSED BY THE CITY OF NEWPORT BEACH. THE MANUFACTURER'S REQUIREMENTS OF RECOMMENDATIONS FOR ANY INCORPORATED PRODUCTS. 2. FEES: CONTRACTOR AND HIS SUB-CONTRACTORS SHALL OBTAIN AND PAY FOR ALL PERMITS, LICENSES, CONSTRUCTION TAXES AND FEES REQUIRED BY CITY, COUNTY AND STATE LAWS EXCEPT THE GENERAL BUILDING PLANCHECK FEE AND REQUIRED REFUNDABLE DEPOSITS WHICH WILL BE PAID BY THE OWNER. CONTRACTOR SHALL ARRANGE FOR ALL METER INSTALLATIONS AND PAY ALL FEES FOR SAID METERS. CONTRACTOR SHALL PROVIDE TEMPORARY TOILET FACILITIES AND EROSION CONTROL MEASURES AS REQUIRED BY STATE AND LOCAL BUILDING CODE. 3. CONTRACTOR'S SURVEY: CONTRACTOR SHALL VISIT THE JOB SITE AND BE RESPONSIBLE FOR HAVING COMPLETE KNOWLEDGE OF EXISTING CONDITIONS. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS WITH THOSE SHOWN ON THE DRAWINGS AND SHALL VERIFY GRADES, CONDITIONS AND DIMENSIONS PRIOR TO COMMENCING DEMOLITION AND CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY VERBALLY AND IN WRITING OF DISCREPANCIES BETWEEN ACTUAL CONDITIONS AND THOSE DEPICTED IN THE CONTRACT DOCUMENTS. CONTRACTOR SHALL NOTIFY ARCHITECT IMMEDIATELY VERBALLY AND IN WRITING OF ANY DISCREPANCIES FOUND WITHIN THE DRAWINGS AND SPECIFICATIONS. 4. COORDINATION OF CONSTRUCTION: CONTRACTOR IS SOLELY RESPONSIBLE FOR THE ACCURACY OF DETAILS; FOR CONFIRMING AND COORDINATING ALL QUANTITIES AND DIMENSIONS; FOR SELECTING FABRICATION PROCESSES; FOR TECHNIQUES OF ASSEMBLY AND PERFORMANCE OF ALL WORK IN A SAFE AND SATISFACTORY MANNER. CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF ALL WORK INCLUDING THAT OF THE SUB-CONTRACTORS. CONTRACTOR SHALL PROVIDE SUPERVISION OF THE JOB DURING ALL PHASES OF CONSTRUCTION ACTIVITIES. A COMPETENT SUPERINTENDENT SHALL BE SELECTED BY THE CONTRACTOR AND SHALL BE IN CHARGE OF THE JOB UNTIL ITS COMPLETION. CONTRACTOR AGREES TO BIND EVERY SUB-CONTRACTOR BY THE TERMS OF THE CONTRACT AS FAR AS SUCH TERMS ARE APPLICABLE TO THE SUB-CONTRACTOR'S WORK. 5. CLEAN-UP: ALL SUB-CONTRACTORS SHALL BE RESPONSIBLE FOR THE DAILY REMOVAL OF ALL DEBRIS ACCUMULATED AS A RESULT OF THEIR OPERATIONS. ALL SCRAP DEBRIS AND OTHER EXCESS MATERIAL SHALL BE LAWFULLY REMOVED FROM THE SITE, UNLESS OTHERWISE DIRECTED BY THE CONTRACTOR. 6. TESTS AND PERMITS: CONTRACTOR SHALL ARRANGE FOR, AND SECURE REQUIRED TESTS, PERMITS AND INSPECTIONS, AND SHALL BEAR COSTS FOR SAME. 7. GUARANTEES: CONTRACTOR SHALL GUARANTEE ALL WORK, MATERIALS AND PRODUCTS FOR ONE YEAR AFTER THE DATE OF ACCEPTANCE OF THE WORK AND CONTRACTOR SHALL REPAIR OR REPLACE, OR CAUSE TO BE REPAIRED OR REPLACED ANY OR ALL SUCH WORK TOGETHER WITH ANY OTHER WORK WHICH MAY BE DISPLACED IN DOING SO, THAT MAY PROVE DEFECTIVE WITHIN ONE YEAR, WITHOUT ADDITIONAL EXPENSE; ORDINARY WEAR AND TEAR, UNUSUAL ABUSE OR NEGLECT IS EXCEPTED. EXCEPTIONS TO ONE YEAR GUARANTEE ARE SPECIFIED IN OTHER SECTIONS OF THE PROJECT MANUAL OR DRAWINGS. STATE LAW, OR MANUFACTURER'S GUARANTEE SHALL GOVERN IF LENGTH AND TYPES OF GUARANTEES ARE MORE STRICT OR FOR LONGER PERIODS. IT IS UNDERSTOOD BY CONTRACTOR THAT IT IS HIS RESPONSIBILITY TO PROVIDE MATERIALS AND CONSTRUCTION WHICH WILL YIELD A REASONABLE VALUE OVER A PERIOD OF TIME WHICH MAY EXCEED THE SPECIFIED GUARANTEE AND WARRANTY PERIODS. CONTRACTOR SHALL BE RESPONSIBLE FOR A WEATHER TIGHT BUILDING, FREE FROM DEFECTS OF MATERIALS AND WORKMANSHIP. EACH SUB-CONTRACTOR SHALL PROVIDE A WRITTEN GUARANTEE STATING THAT WORK EXECUTED BY HIM IS FREE AND WILL REMAIN FREE FROM DEFECTS OF MATERIALS AND WORKMANSHIP FOR ONE YEAR FROM DATE OF ACCEPTANCE OF HIS WORK BY OWNER, AND THAT REPAIR AND REPLACEMENT OF SUCH DEFECTIVE WORK AND ALL OTHER WORK DAMAGED AS A RESULT THEREBY WILL BE EXECUTED IN A TIMELY MANNER AT THE CONVENIENCE OF THE OWNER AND WITHOUT COST TO OWNER. 8. WAIVER OF LIENS: CONTRACTOR SHALL PROVIDE CERTIFIED RELEASE OF LIENS BY ALL SUB-CONTRACTORS AND SUPPLIERS, OR ANYONE PROVIDING MATERIALS AND/OR LABOR AS THEY BECOME AVAILABLE. 9. ROLL OF ARCHITECT DURING CONSTRUCTION: THE ARCHITECT WILL NOT ACT AS THE OWNER'S REPRESENTATIVE DURING CONSTRUCTION. ARCHITECT WILL ADVISE AND CONSULT WITH OWNER. ARCHITECT WILL OBSERVE CONSTRUCTION PER HIS AGREEMENT WITH OWNER AND RENDER INTERPRETATIONS NECESSARY FOR THE PROPER EXECUTION OR PROGRESS OF THE WORK IN ACCORDANCE WITH THE INTENT OF THE PLANS AND SPECIFICATIONS. ARCHITECT WILL NOT BE RESPONSIBLE OR HAVE CONTROL OR CHARGE OVER THE ACTS OR OMISSIONS, CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS, OF THE CONTRACTOR, SUB-CONTRACTORS, OR ANY OF THEIR AGENTS OR EMPLOYEES, OR ANY OTHER PERSONS PERFORMING ANY OF THE WORK. ANY VERBAL INSTRUCTION OR AUTHORIZATION THAT IS CONFIRMED BY LETTER, MEETING NOTE, MEMORANDA, OR THE LIKE, (WITH A COPY SENT TO THE OWNER, OR THE OWNER'S REPRESENTATIVE) & THERE IS NO EXCEPTION TAKEN WITHIN (10) CALENDAR DAYS, SHALL BE DEEMED EQUIVALENT TO RECEIPT OF WRITTEN INSTRUCTION, APPROVAL AND AUTHORIZATION FROM THE OWNER. 10. A.I.A. GENERAL CONDITIONS: THE CURRENT GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION PUBLISHED BY THE AMERICAN INSTITUTE OF ARCHITECTS SHALL APPLY AS THOUGH IT WERE PART OF THESE DOCUMENTS UNLESS SPECIFICALLY MODIFIED IN THE OWNER/CONTRACTOR AGREEMENT. A COPY OF SAID GENERAL CONDITIONS MAY BE OBTAINED FROM THE ARCHITECT UPON REQUEST. THE NOTES CONTAINED IN THESE "GENERAL NOTES" ON THIS SHEET ARE INTENDED TO SUMMARIZE AND COMPLIMENT THE A.I.A. GENERAL CONDITIONS. THE A.I.A. GENERAL CONDITIONS SHALL TAKE PRECEDENCE OVER THESE NOTES SHOULD A CONFLICT IN WORDING OCCUR. 11. EXTRAS: OWNER MAY ORDER EXTRA WORK OR MAKE CHANGES BY ALTERING, ADDING TO OR DEDUCTING FROM THE WORK, THE CONTRACT SUM BEING ADJUSTED TO THE MUTUAL SATISFACTION OF THE OWNER, ARCHITECT AND CONTRACTOR. BEFORE ANY CHANGES ARE BEGUN, THE ADDED OR DEDUCTED SUM SHALL BE PRESENTED TO OWNER IN WRITING FOR APPROVAL. 12. SUBSTITUTIONS: SUBSTITUTIONS OF MATERIALS OR METHODS PROPOSED BY THE CONTRACTOR OR HIS SUB-CONTRACTORS CONTRARY TO DRAWINGS AND SPECIFICATIONS SHALL BE SUBMITTED TO ARCHITECT IN WRITING FOR APPROVAL OR DENIAL. IF MORE THAN ONE MANUFACTURER IS SPECIFIED IN THE PLANS OR SPECIFICATIONS, IT SHALL BE THE CONTRACTOR'S OPTION TO SELECT THE ONE WHICH HE MAY DESIRE. IF MORE THAN ONE FINISH OR STYLE IS AVAILABLE IN THE ITEM SPECIFIED, CONTRACTOR SHALL BE OBLIGATED TO NOTIFY ARCHITECT VERBALLY AND IN WRITING OF THIS FACT FOR ARCHITECT'S AND OWNER'S DECISION. WHERE THE TERM "OR EQUAL" IS USED IN DRAWINGS OR SPECS IT SHALL BE UNDERSTOOD THAT THE REFERENCE IS MADE SUBJECT TO THE RULING AND JUDGMENT OF THE ARCHITECT AND SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW AND APPROVAL. ACTUAL SAMPLES OF THE SUBSTITUTIONS SHALL ALSO BE SUBMITTED TO THE ARCHITECT FOR REVIEW AND APPROVAL. 13. INSURANCE: CONTRACTOR SHALL CARRY GENERAL LIABILITY INSURANCE WITH BROADFORM PROPERTY DAMAGE ENDORSEMENT AND CONTINGENT LIABILITY ENDORSEMENT. OWNER AND ARCHITECT SHALL BE LISTED AS ADDITIONAL INSURERS UNDER THE POLICY WITH WAIVER OF SUBROGATION. CONTRACTOR SHALL FURNISH OWNER WITH A CERTIFICATE OF INSURANCE WITH A 30 DAY NOTICE OF CANCELLATION. OWNER SHALL OBTAIN A BUILDER'S RISK POLICY WITH ARCHITECT NAMED AS AN ADDITIONAL INSURED WITH WAIVER OF SUBROGATION. 14. SCOPE OF DRAWINGS AND SPECIFICATIONS: THESE DRAWINGS AND SPECIFICATIONS SHALL BE INTENDED TO SHOW AND DESCRIBE DETAILS FOR A CONSTRUCTIBLE BUILDING. PARTS AND DETAILS NOT FULLY SHOWN OR DESCRIBED SHALL BE DETAILED AND EXECUTED ACCORDING TO STANDARD FIRST CLASS PRACTICE AND IN SIMILAR MANNER AND SPIRIT OF THE DETAILS WHICH ARE SHOWN ON THE DRAWINGS AND/OR DESCRIBED IN THE PROJECT MANUAL. IF CONTRACTOR OR SUB-CONTRACTOR FINDS ANY DETAILS WHICH, IN HIS OPINION, ARE UNSOUND, UNSAFE, OR NOT WATERPROOF, IT IS HIS DUTY TO NOTIFY ARCHITECT IN WRITING OF THIS FACT. IF WORK IS PERFORMED AS DETAILED, IT WILL BE ASSUMED THAT THERE ARE NO OBJECTIONS TO THE DETAIL. ACCURACY OF ALL DIMENSIONS SHALL BE CHECKED. NO EXTRA COMPENSATION WILL BE ALLOWED FOR DIFFERENCE BETWEEN ACTUAL DIMENSIONS AND THOSE INDICATED ON THE DRAWINGS. IN USING THESE PLAN FOR BIDDING OR CONSTRUCTION PURPOSES, ALL CONTRACTORS ARE REQUIRED TO REVIEW AND TREAT THEM AS A WHOLE IN ORDER TO IDENTIFY ALL REQUIREMENTS THAT DIRECTLY OR INDIRECTLY AFFECT THEIR PORTION OF THE WORK, EVEN REQUIREMENTS LOCATED IN SECTIONS DESIGNATED AS APPLICALBE TO OTHER TRADES. IN CAS OF CONFLICTS, THE AFFECTED CONTRACTOR IS REQUIRED TO EITHER OBTAIN DIRECTION FROM AN APPROPRIATE REPRESENTATIVE OF THE OWNER, OR OTHERWISE TO APPLY THE MORE STRINGENT STANDARD. THESE PLANS ARE INTENDED TO SET FORTH THE REQUIREMENTS FOR CONSTRUCTION IN ONLY AN INDUSTRY-STANDARD LEVEL OF QUALITY AND DETAIL, AND THE ARE INTENDED TO BE SUPPLEMENTED BY APPROPRIATE REQUESTS FOR CLARIFICATION AND INFORMATION. ERRORS AND OMISSIONS ARE TO BE EXPECTED AND ANTICIPATED, AND ALL CONTRACTORS ARE REQUIRED TO CAREFULLY REVIEW THESE PLANS FOR ERRORS AND OMISSIONS AND TO BRING THESE ERRORS AND OMMISIONS TO THE ATTENTION OF A APPROPRIATE OWNER & ARCHITECT IN WRITING IN A TIMELY MANNER; AND ANY CONTRACTOR WHO FAILS TO DO SO BEFORE BIDDING OR OTHERWISE PROCEEDING ASSUMES THE RISK OF ANY CONSEQUENCES. SCALED DIMENSIONS SHOULD BE CONSIDERED ONLY APPROXIMATE; AND IN ANY DIMENSIONS BEFORE PROCEEDING WITH ANY AFFECTED PROCUREMENT, FABRICATION OR CONSTRUCTION. SCHEMATIC PLANS ARE INTENDED ONLY TO DEMONSTRATE THE RELATIONSHIP AMONG COMPONENT PARTS, AND NOT TO DEPICT SPECIFIC LOCATIONS (e.g. SCHEMATIC ELECTRICAL PLANS). 15. DIMENSIONS ON DRAWINGS: FIGURED DIMENSIONS SHALL BE FOLLOWED IN PREFERENCE TO SCALE, AND DETAIL DRAWINGS IN PREFERENCE TO SMALL SCALE DRAWINGS. SUB-CONTRACTOR AND CONTRACTOR SHALL CHECK ACCURACY OF ALL DIMENSIONS IN THE FIELD PRIOR TO ANY WORK BEING CONSTRUCTED OR MATERIALS OR PRODUCTS FABRICATED OR ORDERED. SPECIFICATIONS AND WRITTEN NOTES AND SCHEDULES ON DRAWINGS SHALL BE FOLLOWED IN PREFERENCE TO INFORMATION FURNISHED IN THE FORM OF LINE DRAWINGS. DETAILED DRAWINGS FURNISHED DURING CONSTRUCTION OR APPROVED BY CONTRACTOR OR ARCHITECT ARE TO BE CONSIDERED EXPLANATORY AND NOT AS CHANGES TO DRAWINGS AND SPECIFICATIONS. NOTES, FIGURES AND DETAILS ON SAID DRAWINGS SHALL BE FOLLOWED AND EXECUTED AS IF PART OF THESE DOCUMENTS. DRAWINGS ARE NOT TO BE SCALED UNLUESS PERMITTED BY THE ARCHITECT. DIMENSIONS SHALL GOVERN. ALL EXTERIOR DIMENSIONS ARE BASED ON NOMINAL SIZES OF MEMBERS AND ARE GIVEN TO THE OUTER FACE OF SUCH MEMBERS, UNLESS OTHERWISE NOTED ON DRAWINGS. INTERIOR PARTITIONS ARE DIMENSIONED FROM FACE OF STRUCTURE TO FACE OF STRUCTURE UNLESS OTHERWISE NOTED ON DRAWINGS. WHERE DIMENSION IS LABELED "CLEAR" IT IS TAKEN FROM THE FACE OF FINISH TO FACE OF FINISH OF EACH MATERIAL. PLUS OR MINUS (+/-) DIMENSIONS SHALL NOT VARY BY MORE THAN 2" WITHOUT APPROVAL BY ARCHITECT. WALL ANGLES ARE EITHER 90° OR 45° UNLESS NOTED OTHERWISE. 16. SUBMITTALS, MEETING NOTES, BULLETINS, AND MEMOS: SUBMITTALS WILL BE REVIEWED BY THE ARCHITECT, IF AT ALL, ONLY PURSUANT TO THE INDUSTRY-STANDARD PROTOCOL SET FORTH IN AIA DOCUMENT A201-1997; AND IN NO EVENT WILL THE SUBMITTAL REVIEW PROCESS RELIEVE OR LESSEN THE SUBMITTING CONTRACTOR'S RESPONSIBILITY FOR AN INAPPROPRIATE SUBMITTAL. ARCHITECT, FROM TIME TO TIME, WILL ISSUE CONSTRUCTION NOTES OR MEMOS REGARDING CONSTRUCTION ISSUES THAT HAVE ARISEN SINCE THE DRAWINGS AND SPECIFICATIONS WERE COMPLETED. CONTRACTOR SHALL REVIEW THESE WRITTEN DOCUMENTS AND INCORPORATE THEM INTO THE PROJECT. ANY QUESTIONS OR OBJECTIONS AS TO THE INTENT OF THE WRITTEN DOCUMENT ITEMS WILL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT FOR DISCUSSION AND OR CLARIFICATION. ANY ITEM THAT RESULTS IN A CHANGE TO THE COST OR TIMING OF THE PROJECT SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE OWNER & ARCHITECT PRIOR TO EXECUTING. CONTRACTOR SHALL SUBMIT FABRICATION SHOP DRAWINGS TO THE ARCHITECT FOR APPROVAL PRIOR TO ORDERING AND/OR FABRICATION. CONTRACTOR SHALL SUBMIT MANUFACTURER'S CUTS FOR ALL FIXTURES AND EQUIPMENT CALLED FOR ON THE CONSTRUCTION DOCUMENTS TO ARCHITECT INCLUDING BUT NOT LIMITED TO LIGHT FIXTURES, HARDWARE, PLUMBING FIXTURES, KITCHEN EQUIPMENT, ETC. BY SUBMITTING SHOP DRAWINGS AND PRODUCT DATA, THE CONTRACTOR REPRESENTS THAT HE/SHE HAS VERIFIED FIELD CONDITIONS, DIMENSIONS AND RELATED CONSTRUCTION AND HAS COORDINATED THE SUBMISSION CONSTUCTION WITH THE REQUIREMENTS OF ALL OTHER RELATED WORK IN THE CONSTRUCTION DOCUMENTS. ALL SHOP DRAWINGS AND CUTS MARKED "REVIEWED" BY ARCHITECT, ARE FOR VERIFCATION OF ADHERENCE TO THE DESIGN INTENT ONLY. THE CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR ALL MEANS AND METHODS AND ERRORS AND OMISSIONS ON THEIR DRAWINGS. CONTRACTOR TO SUBMIT A COMPLETE SHOP DRAWINGS AND OR SUBMITTAL FOR APPROVAL BEFORE COMMENCING FABRICATION AND/OR INSTALLATION OF ALL APPLICABLE ITEMS. ALL SHOP DRAWINGS DIMENSIONS SHALL BE FIELD VERIFIED, REVIEWED AND APPROVED BY CONTRACTOR BEFORE SUBMITTAL. SHOP DRAWINGS WHICH ARE INCOMPLETE OR LACKING SUFFICIENT INFORMATION WILL BE RETURNED WITHOUT REVIEW. SUBMIT SAMPLES FOR INITIAL SELECTION PURPOSES OF ACTUAL VENEERS SHOWING A FULL RANGE OR GRAIN VARIATION, FINISH AND PATTERNS PROPOSED. SUBMIT SAMPLES AS REQUIRED UNTIL APPROVED BY ARCHITECT. SAMPLES SHALL BE 12" X 12" MIN., ONE UNIT OF EACH TYPE AND FINISH. 17. ERRORS AND OMISSIONS: ERRORS OR OMISSIONS WHICH APPEAR ON THE DRAWINGS, IN SPECIFICATIONS OR OTHER CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT BY THE CONTRACTOR AND TO THE CONTRACTOR BY THE SUB-CONTRACTOR IN WRITING. IN EVENT OF FAILURE OF SUB-CONTRACTOR TO GIVE SUCH WRITTEN NOTIFICATION BEFORE CONSTRUCTION OR FABRICATIONS OF THE WORK, HE WILL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY SUCH ERRORS OR OMISSIONS AND THE COSTS OF RECTIFYING SAME. HOWEVER, DRAWINGS AND SPECIFICATIONS ARE COMPLEMENTARY AND WORK CALLED FOR ON ONE AND NOT THE OTHER SHALL BE PROVIDED AS THOUGH FULLY SET FORTH IN BOTH. 18. BARRICADES: CONTRACTOR SHALL ERECT AND PROPERLY MAINTAIN AT ALL TIMES AS REQUIRED BY CONDITIONS AND PROGRESS OF THE WORK, ALL NECESSARY PROTECTIVE BARRICADES, FENCES AND OTHER SAFEGUARDS FOR THE PROTECTION OF THE WORKERS AND THE PUBLIC. THESE BARRICADES SHALL BE CONSTRUCTED AND BE LOCATED AS SHALL BE DETERMINED BY LOCAL AUTHORITIES AND CODES. 19. TEMPORARY BRACING: AT ALL TIMES DURING CONSTRUCTION ACTIVITIES OR ERECTION OF PROJECT OR ITS COMPONENT PARTS, PRIOR TO COMPLETION OF THE STRUCTURAL FRAME OR REPLACEMENT AND PERMANENT CONNECTION OF COMPONENT MEMBERS TO THE STRUCTURAL FRAME, SUB-CONTRACTORS SHALL PROVIDE, INSTALL AND MAINTAIN PROPERLY DESIGNED AND CONSTRUCTED TEMPORARY BRACING OF ADEQUATE STRENGTH TO PREVENT DISLOCATION, DISTORTION, CRACKING, FALLING OFF, OR ANY OTHER DAMAGE TO WORK OR ANY OF ITS COMPONENT PARTS DUE TO FORESEEABLE NORMAL AS WELL AS NOT FORESEEABLE EXCESSIVE WIND AND EARTHQUAKE FORCES WITHOUT ADDITIONAL COST TO OWNER. CONTRACTOR AND HIS SUB-CONTRACTORS SHALL, AT THEIR EXPENSE, REPLACE OR REPAIR, AS DIRECTED, DAMAGED PORTIONS OF THEIR WORK OR COMPONENT PARTS. 20. TOXIC SUBSTANCES REMOVAL: PRIOR TO ANY WORK BEING PERFORMED, WHENEVER THERE ARE EXISTING STRUCTURES TO BE REMOVED OR ALTERED, CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION AND REMOVAL OF ANY TOXIC MATERIALS OR SUBSTANCES AS REQUIRED BY THE STATE OF CALIFORNIA INCLUDING BUT NOT LIMITED TO ASBESTOS, LEAD PAINTS, MOLD, ETC. REMOVAL AND DISPOSAL SHALL FOLLOW STATE MANDATED METHODS, PROCEDURES, DOCUMENTATION AND APPLICATION REQUIREMENTS. 21. NO CHANGES ARE TO BE MADE ON THESE PLANS WITHOUT THE KNOWLEDGE OR CONSENT OF THE ARCHITECT/ ENGINEER WHOSE SIGNATURE APPEARS HERON. 22. NO FRAMING OF ANY TYPE TO BE CONCEALED PRIOR TO INSPECTION BY GOVERNING AGENCIES. 23. REFERENCES TO ANY DETAIL OR DRAWINGS IS FOR CONVENIENCE ONLY AND DOES NOT LIMIT THE APPLICATION OF SUCH DETAIL OR DRAWINGS. 24. USE 2x6 MINIMUM STUDS FOR PLUMBING WALLS 25. MAXIMUM FLOW RATE STANDARDS SET BY THE CURRENT CALIFORNIA GREEN CODE - G.C. TO VERIFY PRIOR TO PURCHASE AND INSTAL. OF ANY FIXTURES. 26. EXTERIOR DECKS, BALCONIES, AND STAIRWAYS SEALED UNDERNEATH SHALL BE WATERPROOFED- ARCH. TO APPV. METHOD OF WATERPROOFING - G.C. TO SUBMIT SPECIFICATIONS. 27. SPECIAL INSPECTION IS REQUIRED FOR THE FOLLOWING: * FOUNDATION INSPECTION BY SOILS ENGINEER PRIOR TO CONCRETE POUR AND: * PER SOILS REPORT: OVER EXCAVATION, RECOMPACTION, FOOTING DEPTH, UTILITY TRENCH BACK FILL * RETAINING WALL BACK FILL, PRE SATURATION OF SLAB AREAS, EXTERIOR FLAT WORK AREAS. * ALL TO BE ADDRESSED IN A REPORT PRESENTED TO BUILDING DEPT. PRIOR TO FINAL * ALL FIELD WELDING OF STRUCTURAL STEEL * INSTALLATION OF ALL HIGH STRENGTH BOLTS * CERTIFICATION OF WELD, & BOLTING TO BE GIVEN TO BUILDING DEPARTMENT PRIOR TO FRAMING INSPECTION. 28. MAX. TEMP. OF 120° TO BE APPROVED BY THE USE OF PRESSURE BALANCE OR THERMOSTATIC MIXING VALVES TYP. @ SHOWERS & TUBS. 29. MAINTENANCE INFORMATION: THE BUILDER SHALL PROVIDE TO THE BUILDING OWNER AT OCCUPANCY MAINTENANCE INFORMATION FOR ALL FEATURES, MATERIALS, COMPONENTS, AND MANUFACTURED INFORMATION FOR ALL FEATURES, MATERIALS, COMPONENTS AND MANUFACTURED DEVICES THAT REQUIRE ROUTINE MAINTENANCE FOR EFFICIENT OPERATION. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY STATED AND INCORPORATED ON A READILY ACCESSIBLE LABEL. THE LABEL MAY BE LIMITED TO IDENTIFYING, BY TITLE AND/OR PUBLICATION NUMBER, THE OPERATION AND MAINTENANCE MANUAL FOR THAT PARTICULAR MODEL AND TYPE OF FEATURE, MATERIAL, COMPONENT, OR MANUFACTURED DEVICE. 30. AFTER INSTALLING WALL, CEILING, OR FLOOR INSULATION, THE INSTALLER SHALL MAKE AVAILABLE TO THE ENFORCEMENT AGENCY OR POST IN A CONSPICUOUS LOCATION IN THE BUILDING A CERTIFICATE SIGNED BY THE INSTALLER STATING THAT THE INSTALLATION IS CONSISTENT WITH THE PLANS AND SPECIFICATIONS FOR WHICH THE BUILDING PERMIT WAS ISSUED. THE CERTIFICATE SHALL ALSO STATE THE MANUFACTURER'S NAME AND MATERIAL IDENTIFICATION, THE INSTALLED R-VALUE, AND (IN APPLICATIONS OF LOOSE FILL INSULATION) THE MINIMUM INSTALLED WEIGHT PER SQUARE FOOT CONSISTENT WITH THE MANUFACTURER'S LABELED INSTALLED DESIGN DENSITY FOR THE DESIRED R- VALUE. 31. ON PROJECTS WITH EXCAVATIONS THAT WILL BE LOWER THAN ADJOINING PROPERTIES, 30 DAY NOTICE IS LEGALLY REQUIRED BY THE OWNERS & CONTRACTORS TO THE ADJOINING PROPERTY OWNERS OUTSIDE THE SETBACK AREA. 32. DISTANCE FROM THE FACE OF FOUNDATION TO PROPERTY LINE TO BE ZONING SETBACK PLUS WALL FINISH THICKNESS. 33. ROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR FIXTURES SHALL BE PROVIDED WITH ON EXHAUST FAN WITH A MINIMUM CAPACITY OF 50 CFM. DUCTLESS FANS ARE UNACCEPTABLE. CBC 1203.4.3.2.1, CMC T-4-4 34. SAFETY GLAZING SHALL BE PROVIDED AT THE FOLLOWING HAZARDOUS LOCATIONS: CBC 2406.3 A. SWINGING AND SLIDING DOORS B. WHEN LOCATED WITHIN 60- INCHES OF THE FLOOR SURFACE IN TUBS, SHOWERS, SUANAS, OR STEAM ROOMS. C. WITHIN A 24-INCH ARC OF EITHER VERTICAL EDGE OF DOORS AND WITHIN 60-INCHES OF WALKING SURFACE. D. WHERE GLAZING AREA IS MORE THAN 9 SQ. FT. IN AREA, WITH A BOTTOM EDGE LESS THAN 18-INCHES ABOVE THE FLOOR AND TOP EDGE MORE THAN 36-INCHES ABOVE FLOOR. E. ADJACENT TO STAIRWAYS, LANDINGS AND RAMPS WITHIN 36-INCHES HORIZONTALLY OF WALKING SURFACE AND WITHIN 60-INCHES ABOVE WALKING SURCFACE. F. ADJACENT TO STAIRWAYS WITHIN 60-INCHES HORIZONTALLY OF BOTTOM TREAD OF STAIRWAY AND EXPOSED SURFACE IS WITHIN 60-INCH ABOVE NOSE OF TREAD. 35. CLEARANCE FOR WATER CLOSET TO BE A MINIMUM OF 24-INCHES IN FRONT AND 15-INCHES FROM ITS CENTER TO ANY SIDE WALL OR OBSTRUCTION. CPC 407.5 36. THE NET AREA OF THE SHOWER ENCLOSURE SHALL BE 1,024 SQ. INCHES (7.1 SQ. FT.) OR MORE IN THE CLEAR FLOOR AREA, AND SHALL ALSO BE CAPABLE OF ENCOMPASSING A 30-INCH DIAMETER CIRCLE. CPC 411.7 37. WALL COVERINGS OR SHOWERS OR TUBS WITH SHOWERS SHALL BE OF CEMENT PLASTER, TILE, OR APPROVED EQUAL, TO A HEIGHT OF NOT LESS THAN 70-INCHES ABOVE DRAIN INLET. PROVIDE CEMENT BOARD OR CEMENT PLASTER BACKING FOR TILE. CBC 1210.3 38. MIN. 5/8" TYPE 'X' MOISTURE RESISTANT GYPSUM WALL BOARD IN ALL BATHROOMS AND KITCHENS 39. EXTERIOR LATH AND PLASTER: PROVIDE TWO LAYERS OF GRADE D PAPER OVER ALL WOOD BASE SHEATHING. CBC 2510.6 40. THE WATER HEATER BURNER TO BE AT LEAST 18-INCHES ABOVE THE GARAGE FLOOR, IF LOCATED IN A GARAGE. CPC 508.14 41. PROVIDE A 3-INCH DIAMETER BY 3-FOOT TALL STEEL PIPE EMBEDDED IN CONCRETE SLAB FOR PROTECTION OF WATER HEATERS IN GARAGE. CPC 508.14 42. WATER HEATERS TO BE STRAPPED AT TOP AND BOTTOM WITH 1-1/2" X 16 GAUGE STRAP WITH 3/8" DIA. X 3" LAG BOLT EACH IND. CPC 508.2 43. DRYER: THE CLOTHES DRYERS VENT SHALL NOT EXCEED 14-FEET IN OVERALL LENGTH. CMC 504.3.2 DRYER VENT TERMINATION MUST BE 3 FT. CLEAR FROM OPENINGS INTO THE BUILDING ( DOORS AND OPERABLE WINDOWS) . CMC 504.5 PROVIDE A MIN. 100 SQ.IN. OPENING IN THE DRYER DOOR. CMC. 504.3.2 44. SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS (R314.3): A. IN EACH SLEEPING ROOM. B. OUTSIDE EACH SEPERATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS C. ON EVERY LEVEL OF DWELLING, INCLUDING BASEMENTS AND HABITABLE ATTICS. SMOKE ALARMS SHALL BE HARDWIRED WITH BATTERY BACK-UP AND INTERCONNECTED UNLESS EXEMPTED IN ACCORDANCE WITH SECTIONS R314.4 & R314.5 45. CARBON MONOXIDE ALARMS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS (R315.3): A. OUTSIDE OF EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOM(S) B. ON EVERY LEVEL OF THE DWELLING UNIT INCLUDING BASEMENTS. CARBON MONOXIDE ALARMS SHALL BE HARDWIRED WITH BATTERY BACK-UP AND INTERCONNECTED UNLESS EXEMPTED IN ACCORDANCE WITH SECTIONS R314.4 & R314.5 46. ALL RECEPTACLE OUTLETS IN BATHROOMS, ABOVE KITCHEN COUNTERTOP, CRAWL SPACES, GARAGE, ROOFTOPS, OUTDOOR OUTLETS, WITHIN 6-FEET OF WET BAR SINK/LAUNDRY SINK TO BE PROTECTED BY GROUND FAULT CIRCUIT INTERRUPTER (GFCI) CEC 210.8 47. ALL 120V SINGLE PHASE, 15 AND 20 AMP OUTLETS (RECEPTACLES, LIGHTING, SMOKE DETECTORS, ETC.) TO BE PROTECTED BY COMBINATION TYPE ARC-FAULT CIRCUIT INTERRUPTER (AFCI) CEC 210.12 48. ELECTRICAL SERVICE TO BE UNDERGROUND FOR NEW CONSTRUCTION OR ADDITIONS >50%. NBMC 12.32.015 49. INSPECTOR TO REVIEW AND APPROVE UNDERGROUND ELEC. SERVICE PRIOR TO CONCRETE PLACEMENT. 50. UTILITY COMPANY APPROVAL IS REQUIRED FOR METER LOCATION PRIOR TO INSTALLATION. 51. FACTORY-BUILT FIREPLACES, CHIMNEYS, AND ALL OTHER COMPONENTS SHALL BE LISTED AND LABELED AND SHALL BE INSTALLED IN ACCORDANCE WITH THE CONDITIONS OF THE LISTING 52. FIREPLACE: DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT THE TERMINATION OF FACTORY-BUILT CHIMNEY SYSTEMS AND ARE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS R1005.4NG. CMC (802.5.2.4) PROVIDE A PERMANENTLY ANCHORED GASEOUS FUEL BURNING PAN TO THE FIREBOX IN A SOLD FUEL BURNING FIREPLACE. SOLID FUEL BRUNING FIREPLACE MUST COMPLY WITH THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES." GAS APPLIANCE FIREPLACE MUST COMPLY WITH THE CALGREEN CODE REQUIRMENTS." 53. ALL DOORS FROM THE HOUSE INTO THE POOL AREA SHALL BE EQUIPPED WITH AN APPROVED ALARM OR AN APPROVED ALTERNATE DROWNING PREVENTION SAFETY FEATURE. CBC 3109.4.4.2 54. GENERAL CONTRACTOR, CONTRACTORS, SUB-CONTRACTORS AND BUILDERS TO COORDINATE ALL ENGINEERING AND MECHANICAL DRAWINGS WITH ARCHITECTURAL DRAWINGS BEFORE PROCEEDING WITH WORK. IF DISCREPANCIES ARE APPARENTLY OBSERVED OR INFORMATION APPARENTLY IS THOUGHT TO BE MISSING, NOTIFY ARCHITECT WITHIN 24 HOURS WITH SKETCH, DRAWING, PDF, PHOTOCOPIES WITH LEGIBLE HAND WRITTEN NOTES AND/OR WRITING (FAX, EMAIL OR CORRESPONDENCE). IF CONFLICT WITH EXISTING CONDITIONS, PROVIDE DOCUMENTATION (PHOTOS, SKETCHES, DWGS) OF EXISTING CONDITIONS AND SUGGEST PROPOSAL(S) FOR SOLUTION (SKETCH, DRAWING, AND/OR WRITING). IN CASE OF ANY DISCREPANCIES, THE ARCHITECT IS THE SOLE INTERPRETER OF THE CONTRACT DOCUMENTS. 55. ISSUANCE OF A BUILDING PERMIT DOES NOT RELIEVE APPLICANTS OF THE LEGAL REQUIREMENTS TO OBSERVE COVENANTS, CONDITIONS AND RESTRICTIONS WHICH MAY BE RECORDED AGAINST THE PROPERTY OR TO OBTAIN PLANS. YOU SHOULD CONTACT YOUR COMMUNITY ASSOCIATIONS PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION AUTHORIZED BY THIS PERMIT. 56. LAND. WALLS LOCATED IN FRONT AND BACK OF PROPERTY SHALL NOT EXCEED 42" HT. REFER. LAND. DWGS FOR LOC'T. 57. LAND. WALLS LOCATED BTW. NEIGHBORS SHALL BE SHARED ON PROP. LINE. REFER. LAND. DWGS AND SEE ATTACHED DOCUMENT FOR "AGRREMENT TO BUILD A FENCE OR WALL CENTERED OVER THE PROPERTY WALL." 58. ALL INTERIOR AND EXTERIOR JOINTS BETWEEN DIFFERENT MATERIALS OR FINISHES SHALL RECEIVE A BEAD OF CAULKING OR SEALANT TO FORM A REVEAL TO MATCH COLOR OF ADJACENT SURFACE. COORDINATE COLORS WITH ARCHITECT. 59. CONTRACTOR SHALL NOTIFY ARCHITECT FOR CLARIFICATION PRIOR TO BIDDING OF ANY DISCREPANCIES BETWEEN ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS. BID SHALL BE BASED ON THE MOST STRINGENT REQUIREMENT. 60. CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT OF ANY UNEXPECTED OR UNKNOWN FIELD CONDITIONS, ERRORS, OMISSIONS, OR DISCREPANCIES IN THE DRAWINGS, PROJECT MANUAL, OR CONTRACT DOCUMENTS PRIOR TO PROCEEDING WITH THE WORK OR SHOP FABRICATIONS. HEATING VENTILATING/AIR COND. DRINKING FOUNTAIN/DOUGLASS FIRD.F. EA. E.P. ENCL. EMER. ELEV. ELEC. EL. E.J.E. DWG. D.S.P. D.S. DR. DN. DIM. DIAG. DIA. EACH EXPANSION JOINT ELEVATION ELEVATOR EMERGENCY ENCLOSURE ELECTRIC PANEL ELECTRIC DIAMETER DIAGONAL DIMENSION DOWN SPOUT DRY STAND PIPE EAST, ENTRY DOWN DOOR DRAWING DET. DEPT. DBL. CTR. CTSK. CORR. CONT. CONST. COND. CONC. CNTR. CLR. CLKG. CLG. C.J. C.I. CHG. CHAN. C.G. CEM. C.B. CAB. CONCRETE CONDITION CONSTRUCTION CONTRACTOR/ CONTINUOUS CORRIDOR, CORROSIVE COUNTERSUNK DEPARTMENT COUNTER CENTER DOUBLE DETAIL CATCH BASIN CORNER GUARD CAST IRON CONTROL JOINT/ CONST. JOINT CAULKING CABINET CEMENT CHANNEL CHANGE CEILING CLEAR LOAD FROM ABOVE JANITOR KITCHEN LANDSCAPED AREA LABORATORY LAMINATE LAVATORY POUNDS LEFT HAND LOCKER LUMINOUS MAINTENANCE MASONRY LBS. LFA MAS. MAINT. LUM. LT. LKR. L.H. LIGHT LAV. LAM. LAB. L.A. L. KIT. JST. JT. JAN. JOINT JOIST LOW/LINEN HOSE BIB HOLLOW CORE HARDWOOD HARDWARE HEIGHT HOLLOW METAL GALVANIZED IRON GLU-LAM BEAM GROUND GYPSUM HORIZONTAL INSULATION INTERIOR INVERT/INVERTED INSIDE DIAMETER/INTERIOR DESIGNER HDWR. I.D. HVAC INV. INT. INSUL. IN. HR. HORIZ. H.M. HT./HGT. HOUR INCH GYP. GR. GND. G.L.B. GL. G.I. HDWD. HD. H.C. H.B. H.HIGH HARD GLASS GRADE AREA DRAINA.D. B.W. BR. B. BOT. BM. BLK'G. BLK. BLDG. BITUM. BET. BD. AUTO. ASSY. ASB. ARCH. APPX. A.P. ANOD. ALT. AL. ADJ. ADH. BITUMINOUS BLOCKING BATH BEDROOM BACK OF WALK, BOT. OF WALL BOARD BETWEEN BUILDING BLOCK BEAM BOTTOM ADHESIVE ADJUSTABLE ALUMINUM ALTERNATE ANODIZED ACCESS PANEL APPROXIMATELY ARCHITECTURAL ASBESTOS ASSEMBLY AUTOMATIC PL LC ACOUS. A.C. A/C A.B. # ∅ @ & ANGLE CENTERLINE DIAMETER OR ROUND PERPENDICULAR POUND OR NUMBER PROPERTY LINE, PLATE ANCHOR BOLT AIR CONDITIONING ASPHALT CONCRETE ACOUSTICAL AT AND FINISH GRADE FLAT HEAD FIXTURE FLOW LINE FLASHING FLUORESCENT FACE OF CONCRETE/FACE OF CURB FACE OF FINISH FACE OF STUD/FACE OF STRUCTURE FACE OF MASONRY FIREPLACE FLOOR SINK FOOT OR FEET FOOTING FURRING FUTURE GALVANIZED GRAB BAR/GRADE BEAM GENERAL GROUND FAULT INTERRUPTG.F.I. GEN. G.B. GALV. GA. FUT. FURR. FTG. FT. F.S. FP. GAUGE F.O.M. F.O.S. F.O.F. F.O.C. FLUOR. FLR. FLASH. F.L. FIX./FIXT. FIN. F.H. F.G. FINISH FLOOR EQUIPMENT EXISTING EXHAUST EXPOSED EXTERIOR FIRE ALARM FLOOR CLEAN OUT FLOOR DRAIN FOUNDATION FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET EQPT./EQPM. F.E.C. F.E. FDN. F.D. F.C.O. F.A. F. EXT. EXPO. EXH. EXST. FIXED SOUTHS. SUPPLY AIR SOLID CORE SCHEDULE SECTION SHELF SHEET SHEATHING SIMILAR SOFFIT JOIST SERVICE SINK STATION STANDARD STEEL STORAGE STRUCTURAL SUSPENDED SYMMETRICAL STAINLESS STEEL SEAT COVER DISPENSER SUB DRAIN/SOAP DISPENSER S.S. SUSP. STRUCT. STOR. SYM. STL. STD. STA. S.SK. S.C.D. SHT'G. SCHED. S.D. S.J. SIM. SHT. SH. SEC. S.C. S.A. PLUMBING PLYWOOD POINT OF CONNECTION PROJECTION POINT RETURN AIR RADIUS ROOF DRAIN RECEPTACLE RECTANGULAR REFERENCE REFRIGERATOR ROOF DRAIN LEADER REGISTER REQUIRED RESILIENT' ROOM REDWOOD REINFORCEMENT ROUGH OPENING RETAIN(ING), RETURN RECT. REINF. RESIL. REQ'D. REFR./ R/F. RET. R.O. RWD. RM. REG. REF. R.D.L. RECPT. PROJ. PLYWD. PLUMB. R.D. RAD. R.A. PT. PR. PNT. PAIR MOUNTEDMTD. MULLION NORTH NATURAL NUMBER NOMINAL NOT TO SCALE OVER OVERALL OBSCURE OFFICE OPENING OPPOSITE PERIMETER PLATE/PROPERTY LINE PLASTER NOT IN CONTRACT NATURAL GRADE OVERFLOW DRAIN PLASTIC LAMINATE OUTSIDE DIAMETER (DIMENSION) O/. P.LAM. O.F.D. PERIM. OPNG. O.D. PLAS. PL. OPP. OFF. OBS. O.A. N.G. N.I.C. N.T.S. NOM. NO. NAT. N. MUL. MATERIAL MAXIMUM MECHANICAL MEMBRANE METAL MAN HOLE MINIMUM MIRROR MOSAIC MEDICINE CABINET MANUFACTURER MISCELLANEOUS MASONRY OPENING MAX. MEMB. MECH. M.O. MISC. MFR./MFGR. M.C. MOS. MIR. MIN. M.H. MET./MTL. MAT. TYPICALTYP. UNIFORM BULIDING CODE UNDERWRITER'S LABORATORY UNLESS NOTED OTHERWISE VENT THROUGH ROOF WEST, WIDE, WIDTH V.T.R. WP. W.I. W.C. W.H. W. WD. W/.WITH WOOD WATER HEATER WATER CLOSET WROUGHT IRON WATERPROOF U.N.O. U.L. U.B.C. VERT. VENT. UR. UNF. U.UNDER UNFINISHED URINAL VENTILATING VERTICAL TOP OF PAVING TOP OF STRUCTURE/SLAB TONGUE AND GROOVE TOP OF CURBT.C. T.&G. T.W. T.O.S. T.PL. T.P. TER. TEMP. TEL. T.CL. TRANS. THK.THICK TRANSFORMER TIME CLOCK TELEPHONE TEMPERED TERRAZZO TOP OF PLATE TOP OF WALL T.TREAD PAINT(ED) P.O.C. EQ.EQUAL / EQUIVALENT FIELD VERIFYF.V. (E.)EXISTING NEW(N.) VER.VERIFY FACTORYFAC. B.O.BY OWNER/BY OTHERS GENERAL CONTRACTORG.C. APPV'D.APPROVED BEL.BELOW ON CENTERO.C. ABV.ABOVE HDR.HEADER SELECTEDSEL. METAL BOLTM.B. PARALLEL STRAND LAMINATEPSL. ROOF RAFTERR.R. /CEILING JOIST FLOOR JOISTF.J. SIMPSONSIMP. T.S.TOP OF STEP UNDERGROUNDU.G. V.VERTICAL W.W.M.WELDED WIRE MESH EACH WAYE.W. DECO.DECORATIVE EXISTING GRADEE.G. GRADE PLANEG.P. 61. CONTRACTOR SHALL PREPARE AND MAINTAIN ALL CONSTRUCTION, AND SURROUNDING AREAS, FREE OF DEBRIS OR HAZARDOUS MATERIALS AT ALL TIMES. CONTRACTOR SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT DUST FROM RISING. 62. CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR AND/OR THE REPLACEMENT OF ANY ITEMS DAMAGED DURING CONSTRUCTION OR CLEAN-UP. ANY DAMAGE TO EXISTING STRUCTURES DURING THE CONSTRUCTION OR THE NEW WORK SHALL BE REPAIRED TO EQUIVALENT OR BETTER THAN ORIGINAL CONDITION AT CONTRACTOR'S EXPENSE. 63. CONSTRUCTION PERSONNEL SHALL BE CONFINED TO THE LIMITS OF THE CONSTRUCTION AREA. ALL OSHA REGULATIONS FOR CONSTRUCTION AREAS SHALL BE STRICTLY FOLLOWED. CONTRACTOR SHALL PROVIDE PROPER SAFEGUARDS DURING ALL PHASES OF CONSTRUCTION. 64. CONTRACTOR TO REMOVE, RELOCATE OR RE-ROUTE, AS NECESSARY, ELECTRICAL, TELEPHONE, WATER, SEWER, GAS OR ANY OTHER UTILITY LINES ENCOUNTERED AND SHALL COORDINATE THIS WORK WILL ALL LOCAL UTILITY COMPANIES. 65. CONTRACTOR SHALL PROVDE TEMPORARY WEATHER PROTECTION FOR PORTIONS OF THE WORK THAT BECOME EXPOSED TO WEATHER AND SHALL BE RESPONSIBLE FOR DAMAGE CAUSED BY INSUFFICIENT PROTECTION. 66. CONTRACTOR TO OBTAIN WRITTEN APPROVAL FROM OWNER AND ARCHITECT PRIOR TO ANY CHANGES OR DEVIATION FROM CONTRACT DOCUMENTS. 67. CONTRACTOR SHALL SUBMIT IN WRITING ALL PROPOSALS FOR ADDITIONAL WORK TO THE OWNER FOR REVIEW AND APPROVAL. NO WORK IS TO PROCEED UNTIL AN AUTHORIZATION TO PROCEED, SIGNED BY THE ARCHITECT & OWNER'S REPRESENTATIVE IS RETURNED TO THE GENERAL CONTRACTOR. 68. CONTRACTOR SHALL BE AWARE THAT SPECIFIC FIRE-RATED SEPARATION WITHIN THE BUILDING'S CONSTRCUTION ARE REQUIRED BY CODE. THE USE OF SPECIFIC MATERIALS AND COMBINATION OF MATERIALS WITHIN FIRE RATED ASSEMBLIES, AS CALLED FOR ON THE DRAWINGS AND SPECIFICATIONS, ARE FOR THE PURPOSE OF ACHIEVING THOSE REQUIRED FIRE SEPARATIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THAT ANY CHANGE IN MATERIAL THAT IS REQUESTED BY OR MADE BY THE CONTRACTOR AND/OR IT'S SUBCONTRACTORS, FROM THOSE MATERIALS DRAWN OR SPECIFIED, DOES NOT IN ANY WAY AFFECT OR LESSEN THE REQUIRED CONSTRUCTION ASSEMBLY. SPECIFIC SEQUENCES OR METHODS OF ACHIEVING FIRE RATED ASSEMBLIES REQUIRED BY A "U.L. NO." LISTING SHALL BE FOLLOWED WITHOUT DEVIATION, UNLESS OTHERWISE NOTED OR DETAILED. 69. CONTRACTOR TO FURNISH AND INSTALL ALL BLOCKING REQUIRED FOR WALL MOUNTED OR BRACED FIXTURES, MILLWORK, SHELVES, TOILET FIXTURES, AND ACCESSORIES OR 'BY OTHER' ITEMS DESCRIBED IN INTERIOR DESIGN AND ARCHITECTURAL DRAWINGS. BLOCKING SHALL BE CONSTRUCTED TO SUPPOR THE IMPOSED LOAD. 70. ALL MANUFACTURED ARTICLES, MATERIALS AND EQUIPMENT SHALL BE SUPPLIED, INSTALLED, CONNECTED, ERECTED, USED, CLEANED AND CONDITIONED AS DIRECTED BY THE MANUFACTURERS. 71. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY/COORDINATE UTILITY REQUIREMENTS FOR ALL OWNER/VENDOR FURNISHED EQUIPMENT, FIXTURES OR APPLIANCES. 72. CONTRACTOR SHALL PROVIDE ALL NECESSARY FASTENERS, SUPPORTS, SHIMMING, FLASH PATCHING, ETC. FOR THE PROPER INSTALLATION OF SUCH ITEMS AS DIRECTED BY THE MANUFACTURERS. 73. UPON COMPLETION OF THE PROJECT, THE CONTRACTOR SHALL GIVE TO THE OWNER A COMPLETE SET OF AS-BUILT CIVIL, LANDSCAPE, ARCHITECTURAL, MECHANICAL, PLUMBING ELECTRICAL AND FIRE PROTECTION DRAWINGS ALONG WITH THE WRITTEN GUARANTIES, OPERATION AND MAINTENANCE MANUALS OF ALL EQUIPMENT AND FINISHES INSTALLED. THE CONTRACTOR SHALL MAINTAIN A CURRENT SET OF AS-BUILT DRAWINGS AND SPECIFICATIONS. INFORMATION SHALL BE RECORDED BY CONTRACTOR AS CONSTRUCTION PROGRESSES AND REVIEWED FOR COMPLETENESS AT EACH REQUISITION REQUEST. 74. CONTRACTOR IS RESPONSIBLE TO THOROUGHLY VACUUM CLEAN ALL CARPETED ARES, CLEAN ALL FLOORING, MILLWORK, LIGHT FIXTURES, GLASS, ETC. AND UNCOVER AND VACUUM OUT ALL MECHANICAL UNITES AFTER THE WORK IS COMPLETED AND MAINTAIN CLEAN CONDITIONS THROUGH THE TENANT'S MOVE-IN. NO. REVISION DATE GENERAL NOTES CONTINUED PARCEL MAP 3 48 JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONSOWNER INFORMATION:PROJECT NAME STATUS These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT T-1.2 03/22/2019 2018-30SUPPLEMENTAL NOTES &DOCUMENTSMODERN BAY FRONT MODERN BAY FRONTSOUTH BAYFRONTWATERPOINTE, LLCGARRETT CALACCI610 NEWPORT CENTERDRIVE, SUITE 890,NEWPORT BEACH, CA92660CDP -FIRST CHECK 402 S BAY FRONTNEWPORT BEACH, CA 92662Designer CAL GREEN -RESIDENTIAL MANDATORY MEASURES RESIDENTIAL CONSTRUCTION MINIMUM REQUIREMENTS 2 1 3 NO. REVISION DATE 49 LOTS 1 & 2SECTION 1BALBOA ISLANDBLOCK 7M.M. 3/42SOUT H BAY F R O N T CL PEARLAVENUECLLOT 3N35°58'27"E 86.30'N43°49'20"W 61.02' N43°50' 0 0 " W 6 1 . 0 5 'N35°59'48"E 86.31'GRAPHIC SCALE1 1TOPOGRAPHIC SURVEY 400 S BAY FRONT #5 NEWPORT BEACH, CA 92662 (APN: 050-043-13)BASIS OF BEARINGS TITLE REPORT/EASEMENT NOTESPAUL D. CRAFT, P.L.S. 8516 DATENOTE: SECTION 8770.6 OF THE CALIFORNIA BUSINESS AND PROFESSIONS CODESTATES THAT THE USE OF THE WORD CERTIFY OR CERTIFICATION BY ALICENSED LAND SURVEYOR IN THE PRACTICE OF LAND SURVEYING OR THEPREPARATION OF MAPS, PLATS, REPORTS, DESCRIPTIONS OR OTHER SURVEYINGDOCUMENTS ONLY CONSTITUTES AN EXPRESSION OF PROFESSIONAL OPINIONREGARDING THOSE FACTS OR FINDINGS WHICH ARE THE SUBJECT OF THECERTIFICATION AND DOES NOT CONSTITUTE A WARRANTY OR GUARANTEE,EITHER EXPRESSED OR IMPLIED.LICENSE RENEWAL DATE 12/31/20STATEOFCALI FORN IA P AUL DOMINICKCRAFTExp. 12/31/20No. 8516P ROFE S S IONALLANDSURVEYORHUNTINGTON BEACH, CALIFORNIA 92646 PHONE:(714)488-5006 FAX:(714)333-4440 APEXLSINC@GMAIL.COM LEGENDCONCRETE SURFACEBRICK SURFACELCEXISTING ELEVATIONBLOCK WALL( )ACASPHALT PAVEMENTSEARCHED, FOUND NOTHING; SET NOTHINGFSFLFINISHED SURFACEFLOWLINEFFGFINISHED FLOOR GARAGET.B.M.TEMPORARY BENCHMARK SET ON SEWERMANHOLE (SMH); ELEVATION = 5.68 FEETFFFINISHED FLOORGAS METERGMCENTERLINETOP OF CURBTCEGEDGE OF GUTTERNATURAL GROUNDNGWOOD FENCE (WDF)WATER METERWMFOUND MONUMENTSURVEYOR OR ENGINEER SHALL PERMANENTLY MONUMENT PROPERTYCORNERS OR OFFSETS BEFORE STARTING GRADING.PLEASE CALL PAUL CRAFT @ 714-488-5006 TO SCHEDULE.SURVEYOR'S NOTES400 SOUTH BAY FRONT #5NEWPORT BEACH, CA 92662(APN: 050-043-13)NO TITLE REPORT PROVIDEDTHE BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF SOUTH BAYFRONT, BEING N43°50'00"W PER P.M.B. 183, PAGES 17/18, RECORDS ON FILE IN THEOFFICE OF THE ORANGE COUNTY SURVEYOR.WOOD FENCEWDFSEWER CLEAN OUTSCOLEGAL DESCRIPTIONREAL PROPERTY SITUATED IN THE CITY OF NEWPORT BEACH, COUNTY OF ORANGE,STATE OF CALIFORNIA DESCRIBED AS FOLLOWS:LOTS 1 & 2 IN BLOCK 7 OF SECTION 1, BALBOA ISLAND, IN THE CITY OF NEWPORTBEACH, COUNTY OF ORANGE, STATE OF CALIFORNIA, AS PER MAP RECORDED INBOOK 6, PAGE 30 OF MISCELLANEOUS MAPS, RECORDS OF ORANGE COUNTY,CALIFORNIA.BENCHMARK INFORMATIONBENCHMARK NO: NB3-15-70DESCRIBED BY OCS 2002 - FOUND 3 3\4" OCS ALUMINUM BENCHMARK DISK STAMPED"NB3-15-70", SET IN THE EASTERLY END OF A CONCRETE SEAWALL. MONUMENT ISLOCATED IN THE SOUTHWEST CORNER OF THE INTERSECTION OFPARK AVENUE AND SOUTH BAY FRONT, 15 FT. SOUTHERLY OF THE CENTERLINE OF PARKAVENUE AND 6 FT. WESTERLY OF PEDESTRIAN WALKWAY. MONUMENT IS SET LEVELWITH THE TOP OF THE SEAWALL.ELEVATION: 7.986 FEET (NAVD88), YEAR LEVELED 1992PALM TREE CLUSTERPCTOP OF STEPTSGUARD POSTGPTRASH BINTBFCFINISHED CONCRETESTORM DRAINSDVICINITY MAPTOP OF BULKHEADTBH3/11/201950 UP OVENCOFFEE DW T UP UP 1005 SF FIRST FLOOR 450 SF 2-CAR GARAGE A B C D E F 33' - 6 5/8"5' - 0 1/4"6' - 2 3/4"20' - 11 1/4"6"23' - 0 3/8"33' - 6 5/8"10' - 7 3/4"21' - 6 1/2"6"11' - 1 7/8"9' - 11 3/8"11' - 8 3/8"11' - 1 7/8"8' - 10 7/8"1' - 6 5/8"1' - 9 5/8"G H 175 SF PATIO 73 SF L1 4' - 3 7/8"8' - 2 1/4"24' - 0 3/8"1 2 1362 SF SECOND FLOOR 282 SF OPEN SPACE 1 123 SF OPEN SPACE 2 A B C D E F G H I 19' - 6 3/8"19' - 8"8' - 7"13' - 7 1/4"6' - 2 1/2"5' - 4"18' - 5 3/4"8' - 2 1/4"6' - 3 5/8"13' - 2 3/4"14' - 8 3/4"13' - 7 1/4"11' - 7 1/8"12' - 3 1/8"23' - 9 7/8"6' - 10 1/8"4' - 0 1/4"5' - 3 1/2"6' - 8 3/8"16' - 0 1/4"8' - 7" 4' - 1" 4' - 3 7/8"8' - 2 1/4"24' - 0 3/8"1 2 3 9' - 6 7/8"2' - 1" 4 5 291 SF THIRD FLOOR 606 SF ROOF DECK 491 SF VIEW DECK A B 6"14' - 6 1/4"5' - 7 3/4"10' - 1 1/4"16' - 0 1/4"C D 13' - 7 1/8"1' - 8 1/4"12' - 0"1' - 7 1/8"6" JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONSOWNER INFORMATION:PROJECT NAME STATUS These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT A-0.1 05/08/2019 2018-30BUILDING AREA PLANSMODERN BAY FRONT MODERN BAY FRONTSOUTH BAYFRONTWATERPOINTE, LLCGARRETT CALACCI610 NEWPORT CENTERDRIVE, SUITE 890,NEWPORT BEACH, CA92660FIRST CHECK 402 S BAY FRONTNEWPORT BEACH, CA 92662Designer NO. REVISION DATE 1/8" = 1'-0"1 FIRST FLOOR PLAN 1/8" = 1'-0"2 SECOND FLOOR PLAN 1/8" = 1'-0"3 THIRD FLOOR PLAN FLOOR PLAN A B C D 33' -6 5/8" X 22' -10 3/8" = 767.1' 5' -0 1/4" X 8' -10 7/8 = 44.7' 6' -2 3/4" X 11' -1 7/8" = 69.4' 10' -7 3/4" X 11' -8 3/8" = 124.5' TOTAL: 1,005 SF E F 20' -11 1/4" X 11' -1 7/8" = 233.5 21' -6 1/2" X 9' -11 3/8" = 214.2 TOTAL: 450 SF GARAGE FLOOR PLAN A B C D 19' -6 3/8" X 18' -5 3/4" = 360.92 13' -4 3/4" X 5' -4" = 71.44 19' -8" X 16' -0 1/4" = 315.07 14' -8 3/4" X 6' -10 1/8" = 100.80 TOTAL: 1,361 SF E F G 4' -0 1/4" X 8' -7" = 34.51 5' -3 1/2" X 4' -1" = 21.60 8' -7" X 6' -8 3/8" = 57.49 H I 13' -7 1/4" X 23' -9 7/8" = 324.09 6' -2" X 12' -2 3/8" = 75.22 FLOOR PLAN A B 14' -6 1/4" X 16' -0 1/4" = 232.63 5' -7 3/4" X 10' -1 1/4" = 57.04 TOTAL: 291 SF G F 0' -6" X 1' -6 5/8" = .77 0' -6" X 1' -6 5/8" = .77 C D 0' -6" X 1' -7 1/8" = .79 0' -6" X 1' -8 1/4" = .84 OPEN AREA CALCS 1 24' -0 3/8" X 8' -2 1/4" = 196.81' 2 24' -0 3/8" X 4' -3 7/8" = 103.8'/2=51.9' TOTAL: 248.71' OPEN AREA CALCS 2 24' -0 3/8" X 8' -2 1/4" = 196.81' 3 24' -0 3/8" X 4' - 3 7/8" = 103.8'/2=51.9' TOTAL: 404.5 1 5' -4" X 6' -1 5/8" = 32.72' 4 9' -6 7/8" X 11' - 7 1/8" = 110.99' 5 11' -7 1/8" X 2' - 1" = 24.16'/2=12.08' OUTDOOR AREA CALCS ROOF DECK 606 VIEW DECK 491 BUILDING AREA SCHEDULE Name AREA COMMENTS FIRST FLOOR 1005 SF SECOND FLOOR 1362 SF THIRD FLOOR 291 SF 2659 SF 2-CAR GARAGE 450 SF 450 SF GRAND TOTAL 3108 SF OUTDOOR AREA SCHEDULE NAME AREA COMMENTS PATIO 175 SF PARTIALLY COVERED L1 73 SF UNCOVERED OPEN SPACE 1 282 SF COVERED OPEN SPACE 2 123 SF PARTIALLY COVERED 654 SF ROOF DECK 606 SF UNCOVERED VIEW DECK 491 SF UNCOVERED 1098 SF GRAND TOTAL 1751 SF LOT INFORMATION: ZONED: R-B1 SITE AREA:2591.66 S.F. BUILDABLE AREA: 1951.72 S.F. TOTAL ALLOWABLE AREA: 1.5 x 1951.72 S.F. = 2927.58 S.F. +200 S.F. = 3127.58 S.F. REQ'D OPEN VOLUME = 1951.72 S.F. X .15 = 292.76 S.F. (7'-6" HT MIN.) OPEN VOLUME PROVIDED= 338 S.F. < 292.76 S.F. TOTAL LIVING TOTAL GARAGE TOTAL OPEN SPACE TOTAL OUTDOOR TOTAL ROOF DECK 51 EXISTING BUILDING GP PLANTER PROPERTY LINE PROPERTY LINE PLANTERSTAIRS FOUND MONUMENT M.M. 3/42 SOUTHCL(6.61)FS(6.95) FS (5.93) FS (6.30) SCO (6.24) FL (6.76) FS (6.92) FS (7.06)FS (7.08) FS (7.42)FS(7.41) FS (7.44)FF (7.43) FF (7.38) FS (7.40) FS (7.43) FF FS NG (6.99) NG (5.99) FS (6.45) FS (6.49) GM (6.06)FS (7.25)TS (6.31)AC(6.48) AC (7.22) FS (7.31) FS (7.38) FS (5.71) (7.41)FS (6.36) FFG (6.34) FS (6.29) GP FS (6.54) AC (7.43)TS (6.94) FS (6.50) FS(8.78)TS (7.50)FS (6.76)FS (8.67)TS(6.92)FSN43°49'20"W 61.02'N35°59'48"E 86.31' R.Y.S.B. 5' - 0"S.Y.S.B.3' - 0"S. BAY FRONT ALLEYEXISTING NOT A PARTN 43° 49' 20" W61.02'EXISTING NOT A PART GREAT ROOM STAIRS/ BAR KITCHEN PANTRY ELEV. 2-CAR GARAGE PWDR. FOYER ENTRY PATIO DINING UP DN UP PLANTEDUP S.Y.S.B.3' - 0"SLOPE PER CIVIL CLR.20' - 0 1/8"CLR. 21' - 5 3/4" CLR. 19' - 0 5/8" CLR. 20' - 10"CLR.5' - 0 1/2"CLR. 4' - 6" 9.00' T.O.S. 9.00' T.O.S. 1 8.92' (N.) T.W.7.83' (N.) T.W. 2 7.83' (N.) T.W. 8.92' (N.) T.W. 13.17' (N.) T.W.13.17' (N.) T.W. 3 3 7.83' T.O.S. 3 4 5 6 N 43° 50' 00" W61.05'N 35° 59' 48" E 86.31' N 35° 59' 48" E 86.31' EXISTING NOT A PART P.L. TO STREET C.L. 7' - 6"F.O.F.1' - 6 5/8"F.O.F.2' - 5 3/4"F.O.F.2' - 6 3/8"F.O.F.2' - 8 1/8"F.O.F.2' - 8 3/8"F.O.F.2' - 11 1/2"F.O.F.3' - 9 7/8"7 F.O.F.3' - 0"3' - 2"F.O.F.3' - 1 1/2"3' - 2"F.O.F.4' - 9 1/8"4' - 11 1/8"F.O.F. 6' - 10 1/4" 7' - 0 1/4" F.O.F. 6' - 10 1/4"5' - 4 3/4" 7' - 0 1/4"F.O.F.3' - 9 7/8"3' - 11 7/8"F.O.F.6' - 2"6' - 3"F.O.F.3' - 11 1/2"4' - 0"5' - 4 7/8" F.O.F. 7' - 5 3/4" 7' - 7 3/4" F.O.F. 7' - 5 3/4" 7' - 7 3/4" UP 6.76 (E.) F.S.6.76 (E.) F.S. 6.76 (E.) F.S. 6.76 (E.) F.S. 6.06 (E.) F.S.6.06 (E.) F.S. TRASH 8 2 21 1 UP 9 9 9 4 4 4 4 10 10 10 10 11 12 11 L L L L L L L L L L L L L L L L L LS. BAY FRONT11' - 5 3/8" 13 14 15 16 NOTE; ENCROACHMENT PERMIT AGREEMENT IS REQ'D. FOR ANY WORK PROPOSED IN THE PUBLIC R.O.W. ALL NON-STANDARD IMPROVEMENTS SHALL COMPY WITH CIY COUNCIL POLICY L-6. NOTE; ENCROACHMENT PERMIT AGREEMENT IS REQ'D. FOR ANY WORK PROPOSED IN THE PUBLIC R.O.W. ALL NON-STANDARD IMPROVEMENTS SHALL COMPY WITH CIY COUNCIL POLICY L-6. 13.17'13.17'CLR.3' - 0"CLR. 3' - 0" 17 18 19 SLOPE PER CIVIL 20 18 19 21 PT. 1 7.22' FS PT. 4 6.92' FS PT. 2 6.48' FS PT. 3 6.45' FS LAVANDULA SPP. LAVENDER (LOW WATER USE) PLANT LEGEND L JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONSOWNER INFORMATION:PROJECT NAME STATUS These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT A-0.0 03/22/2019 2018-30ARCHITECTURAL SITE PLANMODERN BAY FRONT MODERN BAY FRONTSOUTH BAYFRONTWATERPOINTE, LLCGARRETT CALACCI610 NEWPORT CENTERDRIVE, SUITE 890,NEWPORT BEACH, CA92660CDP -FIRST CHECK 402 S BAY FRONTNEWPORT BEACH, CA 92662Designer JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONSOWNER INFORMATION:PROJECT NAME STATUS These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT A-0.0 03/22/2019 2018-30ARCHITECTURAL SITE PLANMODERN BAY FRONT MODERN BAY FRONTSOUTH BAYFRONTWATERPOINTE, LLCGARRETT CALACCI610 NEWPORT CENTERDRIVE, SUITE 890,NEWPORT BEACH, CA92660CDP -FIRST CHECK 402 S BAY FRONTNEWPORT BEACH, CA 92662Designer KEYNOTE LEGEND 1 TILE/STONE PAVERS ON CONCRETE SETTING BED OVER 'WESTCOAT ALX' W.P. MEMBRANE CLASS 'A' ASSEMBLY (ESR-2201) REF. DTL. 10/AD-1 2 FIREPLACE - PREFABRICATED, GAS ONLY - MASON-LITE FIREPLACE, MODEL 'BURNTECH GBVS49' ICC# ESR-2401 [DTL. 22/AD-1] (FACTORY BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR COMPONENTS SHALL BE LISTED AN INSTALLED IN ACCORDANCE W/. THEIR LISTING AND MFG'R. INSTALLATION INSTRUCTIONS. GASEOUS FUEL BURNING PAN MUST BE PERMANENTLY ANCHORED TO THE FIREBOX. FIREPLACE MUST COMPLY W/. THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES.) 3 OUTLINE OF EXISTING BUILDING - TO BE DEMOLISHED 4 STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT CANDLE (CBC 1205.4) REF. DTL. 3/AD-1 5 (E.) GAS METER(S) - REF. CIVIL DWGS. 6 (E.) SEWER C.O. LOCATION (REF. SURVEY & CIVIL DWGS.) 7 ENCLOSED USEABLE SPACE UNDER STAIRWAY USE 5/8" TYPE 'X' GYP. BD. FINISH TYP. (1/2" MIN.) (CRC R302.7) 8 MAIN SERVICE PANEL, 400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION) - VERIFY LOC'N. W/. SO. CA. EDISON 9 HARDSCAPE - COLORED & SCORED CONCRETE (AS SELECTED) PER. LAND. DESIGNER 10 PROPERTY LINE 11 SIDE YARD SETBACK 12 REAR YARD SETBACK 13 PROPOSED (N.) PROPERTY LINE WALL ON NEIGHBORING PROPERTY - NOT A PART 14 LINE OF SECOND FLOOR ABOVE 15 OUTLINE OF OVERHANGS ABOVE 16 (E.) SITE WALL TO BE REMOVED/DEMOLISHED 17 (E.) GUARD POST TO BE REMOVED 18 (N.) PROPERTY LINE WALL (5' - 6" MAX. ABV. N.G.) - STUCCO FINISH TO MATCH 19 (N.) GATE - PER LANDSCAPE DESIGNER (MAX. 5' - 6" HT. ABOVE NATURAL GRADE) 20 EXTERIOR S.S HANDRAIL - 34" - 38" ABV. NOSING (36" TYP. U.N.O.) - 4" MAX. SPHERE OPENING, REF. DTL. 4 /AD-1 21 VEHICLE - MINIMUM PARKING DIMENSIONS ON PLANS TRUE NORTH DIMENSION NOTE: ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE NEAREST 1/8" -CONTACT ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS. 1/4" = 1'-0"1 ARCHITECTURAL SITE PLAN PROJECT NORTH LANDSCAPE NOTES: 1. ENCOARCHMENT PERMIT REQ'D. FOR ANY WORK PROPOSED IN THE PUBLIC R.O.W. 2. IF APPLICABLE, REF. PRELIMINARY LANSCAPE PLAN, FOR ALL HARDSCAPE & PLANTING AREAS WITH REPECTIVE HEIGHTS AND MATERIALS. GENERAL NOTE: SEE SHEET A-3 FOR ROOF PLAN INFORMATION NOT SHOWN ON THIS SHEET (INCLUDING EAVE DETAILS AND PROJECTION DISTANCES). C.N.B. NOTES: 1. ISSUANCE OF A BUILDING PERMIT BY THE CITY OF NEWPORT BEACH DOES NOT RELIEVE APPLICANTS OF THE LEGAL REQUIREMENTS TO OBSERVE COVENANTS, CONDITIONS AND RESTRICTIONS WHICH MAY BE RECORDED AGAINST THE PROPERTY OR TO OBTAIN PLANS YOU SHOULD CONTACT YOUR COMMUNITY ASSOCIATIONS PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION AUTHORIZED BY THIS PERMIT. 2. PRIOR TO PERFORMING ANY WORK IN THE CITY RIGHT-OF-WAY AN ENCROACHMENT PERMIT MUST BE OBTAINED FROM THE PUBLIC WORKS DEPARTMENT. 3. A CAL-OSHA PERMIT IS REQUIRED FOR EXCAVATIONS DEEPER THAN 5' AND FOR SHORING AND UNDERPINNING. NO. REVISION DATENO. REVISION DATE 3/16" = 1'-0"2 GRADE PLANE EXHIBIT PT1. 7.22 PT2. 6.48 PT3. 6.45 PT4. 6.92 27.07 27.07/4 = 6.76 NOTES: 1. THE CONTRACTOR SHALL PROVIDE ALL LABOR, TRANSPORTATION, MATERIALS, AND SERVICES NECESSARY TO FURNISH AND INSTALL ALL CONSTRUCTION ELEMENTS AS SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. 2. ALL WORK SHALL BE PERFORMED BY A CALIFORNIA LICENSED CONTRACTOR. 3. CONSTRUCTION AND INSTALLATION OF ALL LANDSCAPE ITEMS SHALL BE ACCORDING TO STATE, COUNTY AND LOCAL CODES, ORDINANCES AND UP TO CAL- OSHA SAFETY ORDERS REGARDING PERFORMANCE OF WORK. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAKING HIMSELF FAMILIAR WITH THE NATURE AND LOCATION OF ALL UNDERGROUND UTILITIES, PIPES AND STRUCTURES. THE CONTRACTOR SHALL TAKE SOLE RESPONSIBILITY FOR ALL COSTS INCURRED DUE TO DAMAGE AND/OR REPLACEMENT OF SAID UTILITIES, INCLUDING DELAYS. 5. ANY DISCREPANCIES BETWEEN THE FIELD CONDITIONS AND THE CONTRACT DOCUMENTS AND/OR THE DESIGN INTENT AFFECTING THE SUCCESSFUL COMPLETION AND COST OF THE PROJECT SHALL BE REPORTED TO THE OWNER (JOB SUPERINTENDENT) AND LANDSCAPE ARCHITECT IMMEDIATELY. ALL WORK RELATED TO THE PROBLEM ARE SHALL CEASE UNITIL THE DISCREPANCIES HAVE BEEN RESOLVED BY THE OWNER (JOB SUPERINTENDENT) OR LANDSCAPE ARCHITECT IN WRITING. ANY CONTINUATION OF WORK PRIOR TO THE RESOLUTION OF DISCREPANCIES IS AT THE CONTRACTOR'S RISK AND EXPENSE. 6. NO WORK SHALL BE PERFORMED WITHIN THE PUBLIC RIGHT-OF-WAY BY THE APPLICANT/OWNER, OR HIS OR HER AGENTS UNTIL A PUBLIC PROPERTY ENCROACHMENT PERMIT IS ISSUED BY THE CITY ENGINEER. 7. CONTRACTOR SHALL INSTALL THIS PROJECT IN ACCORDANCE TO ALL CITY CODES AND REQUIREMENTS. CONTRACTOR SHALL BRING TO THE ATTENTION OF THE OWNER AND THE LANDSCAPE ARCHITECT PRIOR TO CONSTRUCTION ANY KNOWN DISCREPANCY BETWEEN THAT WHICH IS SPECIFIED ON THESE PLANS AND THAT WHICH IS PERMITTED BY GOVERNING CODES AND THE HOME OWNERS' ASSOCIATION. 8. WITH THE ACCEPTANCE TO CONSTRUCT THIS PROJECT, CONTRACTOR AND OWNER AGREE TO HOLD LANDSCAPE ARCHITECT HARMLESS OF ANY UNFORESEEN CONSTRUCTION COSTS DUE TO ELEMENTS NOT SPECIFIED ON THESE PLANS. 9. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ALL SITE CONDITIONS PRIOR TO COMPLETING BIDS. CONTRACTOR SHALL INCLUDE IN THEIR BID THE COST OF ALL DEMOLITION AND ANY SOIL IMPORT AND OR EXPORT NEEDED TO COMPLETE THIS PROJECT. 10. CONTRACTOR SHALL INSTALL THIS PROJECT UTILIZING THE LANDSCAPE INDUSTRIES'S B.M.P. BEST MANAGEMENT PRACTICES. GENERAL MATERIAL SPECIFICATION: 1. GROUT CELLS WITH REINFORCED CEMENT PER ASTM C150. 1 PART PORTLAND CEMENT, 2 TO 3 PARTS LOOSE SAND, 2 PARTS COARSE AGGREGATE. 2. REINFORCING: FS = 20,000 PSI ASTM A615 GRADE 40. 3. MASONRY: FC = 1,500 PSI GRADE 'A' PER ASTM C150. 4. CONCRETE: FC = 3,500 PSI AT 28 DAYS CEMENT PER ASTM C150. 5. POUR ALL WALL FOOTINGS AGAINST NATURAL UNDISTURBED EARTH. 6. TELEPHONE LANDSCAPE ARCHITECT IF SITE CONDITIONS ARE NOT AS SHOWN. PROJECT HARDSCAPE MATERIALS: STONE SHOULD MATCH THE STONE USED ON THE HOUSE. PAVING STONE SHALL BE SHADOW GRAY SANDSTONE/QUARTZITE. ALL GROUT JOINTS SHALL BE PIGMENTED PER ARCH./G.C. APPROVAL. ALL HARDSCAPE MATERIAL SHALL RECEIVE 6 MIL. VISQUEEN ON UNDER SIDE FOR WATERPROOF PROTECTION. TOTAL LANDSCAPING AREA: 143 SQFT **ALL PLANTS TO BE DROUGHT-TOLERANT NON-INVASIVE PLANT SPECIES 52 53 54 JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONSOWNER INFORMATION:PROJECT NAME STATUS These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT A-1.0 03/22/2019 2018-303-DIMENSIONAL VIEWSMODERN BAY FRONT MODERN BAY FRONTSOUTH BAYFRONTWATERPOINTE, LLCGARRETT CALACCI610 NEWPORT CENTERDRIVE, SUITE 890,NEWPORT BEACH, CA92660CDP -FIRST CHECK 402 S BAY FRONTNEWPORT BEACH, CA 92662Designer NO. REVISION DATE 1 AXONOMETRIC - EAST 2 AXONOMETRIC - SOUTH3AXONOMETRIC - WEST 4 AXONOMETRIC - NORTH 55 OVENCOFFEE DW T NEW WALL -2 x 6 STUDS @ 16" O.C. NEW WALL -2 x 4 STUDS @ 16" O.C. WALL W/. STONE VENEER -2 x 6 STUDS @ 16" O.C. CONCRETE RETAINING WALL -REF. STRUCTURAL CONCRETE MASONRY WALL -6" CMU U.N.O. DOUBLE WALL CONSTRUCTION -2 x 4 MIN. STAGGERED STUD @ 16" O.C. WINDOW -REFERENCE SCHEDULE DOOR -REFERENCE SCHEDULE CABINET -BUILT IN CASEWORK COLUMN -REF. STRUCTURAL DWGS. FURNITURE -FOR PRESENTATION PURPOSES ONLY FIREPLACE -PREFAB GAS-ONLY APPLIANCE PLUMBING FIXTURE -SINK (AS SELECTED) PLUMBING FIXTURE -TOILET (AS SELECTED) PLAN LEGEND LIGHTING FIXTURE -REFERENCE ELECTRICAL PLANS FIRE RATED CEILING ASS'Y. REF. DTL. 7/AD-1 INT. FIRE RATED PARTITION REF. DTL. 7/AD-1 EXT. FIRE RATED PARTITION REF. DTL. 5/AD-1 101 1i ?KEYNOTE TAG -REFERENCE KEYNOTE LEGEND THIS SHT. WINDOW TAG -REFERENCE SHEET A-7.0 DOOR TAG -REFERENCE SHEET A-7.0 1i WINDOW WALL TAG -REFERENCE SHEET A-7.0 1.PROVIDE WHOLE BUILDING MECHANICAL VENTILATION PER ASHRAE STANDARD 62.2-2016 SECTION 4, WITH EXCEPTION THAT NATURAL VENTILATION THROUGH DOORS AND WINDOWS IS NOT AN ACCEPTABLE ALTERNATIVE TO WHOLE-BUILDING VENTILATION (BEES 152(a), EXCEPTION 5 TO SECTION 152(a)). FOR CONTINUOUS WHOLE-BUILDING VENTILATION, MIN. REQUIRED RATE OF VENTILATION IS 1 CFM FOR EACH 100 S.F. OF CONDITIONED FLOOR AREA PLUS 7.5 CFM FOR EACH OCCUPANT (ONE OCCUPANT PER BEDROOM +1). VENTILATION TO BE PROVIDED BY EXHAUST AIR, SUPPLY AIR OR COMBINED EXHAUST AND SUPPLY AIR. 2.PROVIDE IN KITCHEN LOCAL EXHAUST SYSTEM VENTED TO OUTDOORS WITH RATE = 100 CFM (PART OF WHOLE-BUILDING VENTILATION REQUIREMENT). MECHANICAL VENTILATION NOTE: CALCULATIONS: UNIT: 2,655 S.F. (0.03)2,655 S.F.+ [7.5 CFM x OCC. (BED. +1)] = 79.65 CFM + (7.5 x 4) = 109.65 CFM REQ'D. A-4.03 A-4.0 A-4.0 A-4.0 4 1 2 R.Y.S.B. 5' - 0"S.Y.S.B.3' - 0"S.Y.S.B.3' - 0"CLR.3' - 10"CLR. 19' - 0 5/8" 2 A-5.0 2 A-5.0 9.00' T.O.S.1 A-5.0 1 A-5.0 CLR.5' - 0 1/2"CLR. 4' - 6" GREAT ROOM DINING KITCHEN STAIRS/ BAR FOYER PWDR. 2-CAR GARAGE ELEV. ENTRY PATIO PANTRY UP DN UP 4' - 11 1/8"21' - 1 3/8"3' - 11 7/8"10' - 6 5/8"10' - 6 5/8"7' - 7 3/4"66' - 2 7/8"7' - 0 1/4"5' - 4 3/4" 33' - 6 5/8"5' - 0 1/4"27' - 8" 7' - 1 7/8"2"6' - 8 5/8"2' - 6 1/8"17' - 0"2' - 6"2' - 6 1/4"4' - 3 5/8"1' - 7 5/8"21' - 8 3/4"3' - 2"22' - 10 3/8"4' - 0"18' - 0 1/8"4' - 10 1/8"5' - 4 7/8"7' - 7 3/4"66' - 2 7/8"7' - 0 1/4" 44' - 2 3/8"22' - 0 1/2" 1' - 8 3/8"4' - 5 1/8"9' - 0"4' - 6 5/8"24' - 6 1/4"2' - 1 1/4"4' - 3"9' - 8 1/4"6' - 0" 9.00' T.O.S. 7.83' T.O.S. 1 2 3 4 4 5 6 1 1 CLR. 21' - 5 3/4" CLR. 20' - 10"CLR.20' - 0 1/8"1 2 1 32' - 3"2' - 3 1/8"2 4 56 5 789 13 14 15 1' - 9 1/8"15 16 2 21 1 NOTE:PROVIDE MIN. 5/8" TYPE 'X' GYP. TO INSIDE FACE OF ALL GARAGE WALLS. 19 19 19 19 20 20 21 R @ 0' -7 5/8"15 22 4 22 23CLR.2' - 6"CLR. 2' - 11 7/8" 28 31 32 33 34 11 10 353637 BUILT-INBUILT-IN BENCH EAT-IN ISLAND 4037 14 41 10 11 28 42 43 44 A-4.03 A-4.0 A-4.0 A-4.0 4 1 2 2 A-5.0 2 A-5.0 6"2' - 6"8' - 4"2' - 6"6" 1 A-5.0 1 A-5.0 HIS W.I.C. MASTER SUITE LAUNDRY BEDROOM #2 BATH #2 BATH #3 BEDROOM #3 W.I.C. ELEV. STAIRS HER W.I.C.MASTER BATH W/C. M. BALCONY BALCONY 3' - 2"23' - 9 7/8"3' - 0 1/2"11' - 6 5/8"12' - 3 1/8"5' - 9 3/8"5' - 9 3/8"3' - 2 1/8"3' - 2 1/4"2' - 8 3/4"3' - 2 1/8"2' - 7 3/4"11' - 1 5/8"55' - 3"11' - 10 1/2"5' - 4 3/4" 13' - 5 1/4"28' - 2 1/2"13' - 7 1/4" 1' - 9 1/8"9' - 8 7/8"1' - 11 3/4"3' - 9"5' - 0"3' - 3 1/2"2' - 8 1/4"2' - 3 5/8"9' - 0"2' - 3 5/8" 5' - 4 7/8"7' - 7 3/4"67' - 7 1/8"5' - 8" 1' - 5 3/4"1' - 9 5/8"10' - 10"1' - 9 5/8"5' - 4 5/8"7' - 8 1/8"9' - 9 1/8"4' - 11 1/2"2' - 3 1/8"8' - 10 3/4"1' - 9 5/8"5' - 9 3/4"5' - 1 1/2"3' - 2"23' - 9 7/8"3' - 0 1/2"5' - 4"18' - 5 3/4"4' - 4 1/2"13' - 7 5/8"4' - 10 1/8"11 1/2"11 1/2"6' - 1 5/8" DN.UP UP 7 7 2 1 1 6 7 13 14 8 15 16 171819202122 16 17 18 19 20 21 22 23 24 26 25 27 SEATSHOWERTUB SEAT SHOWER SEAT SHOWER 18.58' T.O.S. 19.58' T.O.S. 17 10 2 21 1 5' - 6" 19.58' T.O.S. 22 22 CLR.3' - 8"(2% MIN.) 18.58' T.O.S.1 CLR.5' - 0 1/4"CLR. 4' - 6" (OPEN) 1211 24 2 2 2 25 9 10 11 BARN DR.CLR.2' - 10 1/8"CLR. 3' - 5 5/8" 26 27 28 10 26 CLR. 2' - 6"CLR.2' - 11 1/4"29 CLR. 2' - 6"CLR.2' - 11 1/8"1028 26 30 30 27 27 27 R @ 0' -7 5/8"15 R @ 0' -6"2 R @ 0' -7 5/8"15 TYP.11"CLR. 3' - 6"CLR.3' - 6"TYP.11"TYP. 11" 18 14 BARN DR.283910 30 13 AD-1 2% MIN. 2% MIN. 13 AD-1 6"2' - 6"6' - 4 3/4"2' - 6"6" 6"2' - 6"6' - 6"2' - 6"6" 3' - 3 7/8"7' - 0 7/8"6' - 5 3/8"6' - 1 3/4"4' - 11 1/2"4' - 1 1/2"8' - 8"4' - 5 1/4"6' - 2 1/2" 27 A-4.03 A-4.0 A-4.0 A-4.0 4 1 2 2 A-5.0 2 A-5.0 1 A-5.0 1 A-5.0 BONUS ROOM STAIRS BATH #4 MECH. ELEV. BAR VIEW DECK ROOF DECK 4' - 3 3/4"9' - 5 5/8"12' - 10 3/4"14' - 6 1/4"14' - 2 3/4"13' - 7 1/4"11' - 10 1/2"5' - 4 3/4"3' - 2"22' - 10 3/8"4' - 0"12' - 0 7/8"10' - 9 3/8"2' - 3 1/8"4' - 2 1/4"5' - 7 1/2"3' - 9 3/8"4' - 10 3/4"2' - 1 1/4"1' - 11 5/8"5' - 4 7/8"4' - 3 3/4"3' - 4"18' - 6 3/8"25' - 8"23' - 4 3/4"5' - 8" 2' - 3 5/8"10' - 5"1' - 9 5/8"2' - 0 1/8"3' - 8 1/8"5' - 5 1/2"3' - 2"22' - 10 3/8"11 1/2"3' - 0 1/2"15' - 3 3/8"7' - 7"1' - 8 1/4"12' - 0"1' - 7 1/8"6 1/2" 10' - 7 3/4" 5' - 1 3/4"2' - 9 1/4"2' - 8 3/4" DN.STEP UPFIREPIT 89 10 11 12 13 SPA 42" MAX. HT. (BY SEP. PERMIT) 7 7 7 14 9 10 11 1228 0"4' - 3 3/4"16' - 11"2' - 7"17 1 SHOWER SEAT2 18 11 10 11 10 2 29.17' T.O.S. 2 21 1 11 1/2"2' - 3 5/8"9' - 11"2' - 3 5/8" 24 OUTDOOR SHOWER 17 6' - 2 1/2"12' - 3 1/8"11' - 6 5/8"23' - 9 7/8"CLR.4' - 11 3/8"CLR. 4' - 6" 2 2% MIN. 2% MIN. (OPEN TO BELOW) 6"2' - 6"7' - 11"2' - 6"6"CLR.2' - 6"CLR. 2' - 8 1/2" 28 10 30 38 R @ 0' -7 5/8"15 TYP.11"CLR. 3' - 6"CLR.3' - 6"CLR. 11" 23 28 27 26 32.67' T.R. 32.67' T.R. 32.79' 32.67' T.R. 33.00' 32.83' T.R. 33.00' JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONSOWNER INFORMATION:PROJECT NAME STATUS These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT A-2.0 03/22/2019 2018-30FLOOR PLANSMODERN BAY FRONT MODERN BAY FRONTSOUTH BAYFRONTWATERPOINTE, LLCGARRETT CALACCI610 NEWPORT CENTERDRIVE, SUITE 890,NEWPORT BEACH, CA92660CDP -FIRST CHECK 402 S BAY FRONTNEWPORT BEACH, CA 92662Designer STAIRWAY NOTE: ALL STAIRWAYS SHALL HAVE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT CANDLE PER CRC R303.7 KEYNOTE LEGEND 1 STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT CANDLE (CBC 1205.4) REF. DTL. 3/AD-1 2 FURNISHINGS - AS SELECTED 3 VEHICLE - MINIMUM PARKING DIMENSIONS ON PLANS 4 OUTLINE OF EXISTING BUILDING - TO BE DEMOLISHED 5 FIREPLACE - PREFABRICATED, GAS ONLY - MASON-LITE FIREPLACE, MODEL 'BURNTECH GBVS49' ICC# ESR-2401 [DTL. 22/AD-1] (FACTORY BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR COMPONENTS SHALL BE LISTED AN INSTALLED IN ACCORDANCE W/. THEIR LISTING AND MFG'R. INSTALLATION INSTRUCTIONS. GASEOUS FUEL BURNING PAN MUST BE PERMANENTLY ANCHORED TO THE FIREBOX. FIREPLACE MUST COMPLY W/. THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES.) 6 EXTERIOR COMBUSTION AIR DUCTS SHALL BE LISTED COMPONENTS OF THE FIREPLACE, AND INSTALLED ACCORDING TO THE F.P. MFGR'S. INSTR'S. (CRC R1005) 7 EXTERIOR GLASS GUARD - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTLS. 13/AD-1 8 BBQ, AS SEL. - PROVIDE NATURAL GAS 9 LAUNDRY SINK - AS SEL. 10 COUNTERTOP - AS SELECTED 11 BASE CABINET - BUILT-IN, FINISH AS SEL. 12 PROVIDE POWER FOR BUILT-IN APPLIANCE/EQUIPMENT 13 FIRE PIT LOC'N., PROVIDE GAS AS NEEDED 14 RESIDENTIAL ELEVATOR - 'GARAVENTA LIFT, UPGRADE DOOR PACKAGE STYLE 5,' SHAFT SIZE = 62" X 63 1/2" CLEAR, SLAB DEPRESSION REQ'D PER MFGR. - PROVIDE SHOP DWGS. TO ARCH. PRIOR TO PURCHASE & INSTALLATION 15 MAIN SERVICE PANEL, 400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION) - VERIFY LOC'N. W/. SO. CA. EDISON 16 WATER HEATER - TANK-LESS (ON DEMAND) WALL-MOUNT +44" MIN., 'TAKAGI' OR EQUIV. - VERIFY SIZE REQ'D. W/. MFGR. (PROVIDE ADEQUATE N.G. CONN.) VENT THROUGH ROOF 17 STRUCTURAL STEEL BEAM - REF. STRUCT. DWGS. 18 INTERIOR GUARD - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTLS. 4 & 9/AD-1 19 PROPERTY LINE 20 SIDE YARD SETBACK 21 REAR YARD SETBACK 22 OUTLINE OF OVERHANGS ABOVE 23 LINE OF SECOND FLOOR ABOVE 24 BATHTUB - AS SELECTED (VERIFY LOC'N. OF FIXTURES W/. OWNER) 25 WASHER - PROVIDE HOOK-UPS & POWER - INSTALL PAN & DRAIN UNDER WASHER (TYP.) - G.C. TO VERIFY LOC'N. & SIZE 26 TOILET - MIN. 24" CLR. IN FRONT, MIN. 30" CLR. WIDTH, REF. CAL GREEN NOTES FOR FLOW RATE INFO. 27 SHELF AND POLE - BUILT IN, FINISH AS SEL. 28 SINK - AS SELECTED (VERIFY COUNTER OR WALL MOUNT FIXTURES W/. OWNER) 29 WINDOW TO MEET EGRESS REQ'TS. - REF. WINDOW NOTE #6 ON SCHEDULE 30 SHOWER - HOT-MOP PAN, PROVIDE TILE W/. CEMENT BACKING MIN. 72" HIGH; NET AREA 7.1 S.F. MIN.; 30" DIA. CIRCLE MIN., REF. DTL. 17/AD-1 31 1-3/8" MIN. SOLID CORE DOOR, SELF CLOSING & SELF LATCHING (R302.5.1) 32 1-1/2" MAX. STEP AT OUT SWING DOORS (R311.3.1) 33 GARAGE DOOR - CUSTOM BUILT, ARCH. TO APPV. 34 RANGE - VERIFY APPLIANCE W/. OWNER - PROVIDE HOOD CAPABLE OF 100 CFM MIN. (VERIFY W/. MFGR.) 35 KITCHEN SINK - AS SELECTED 36 DISHWASHER - AS SELECTED 37 CUSTOM BUILT KITCHEN ISLAND PER OWNER & ARCH. 38 TEMPERED GLASS ENCLOSURE - 1/2" THK. (MIN. 3/8" THK.) GLASS TO BE ETCH MARKED (FRAMELESS U.N.O.) 39 BASE CABINET - SINK UNIT, BUILT-IN, FINISH AS SEL. 40 REFRIGERATOR - VERIFY APPLIANCE W/. OWNER 41 KITCHEN EXHAUST HOOD - PROVIDE MIN. RATE OF 100 CFM - INSTALL & PROVIDE POWER PER MFGR'S. INSTRS. 42 INTERIOR HANDRAIL - 34" - 38" ABV. NOSING (36" TYP. U.N.O.), REF. DTLS. 4 & 9/AD-1 43 OVERFLOW DRAIN LINE - IN WALL/ FROM ABV., TO BE METAL VERIFY W/. G.C. (REF. CIVIL DWGS. & DTLS.) 44 DRAIN LINE - IN WALL/FROM ABV., TO BE METAL VERIFY W/. G.C. (REF. CIVIL DWGS. & DTLS.) DIMENSION NOTE: ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE NEAREST 1/8" -CONTACT ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS. 1/4" = 1'-0"1 FIRST FLOOR PLAN 1/4" = 1'-0"2 SECOND FLOOR PLAN *HERS VERIFICATION REQUIRED-REFERENCE T-24.1 A ROUGH FRAMING: ALL EXTERIOR WALLS TO BE FRAMED WITH 2 X 6 STUDS SECOND AND THIRD FLOOR PLYWOOD TO BE 1-1/8" ENTIRE EXTERIOR TO BE SHEATHED WITH 1/2" PLYWOOD NO. REVISION DATE TRUE NORTH PROJECT NORTH 1/4" = 1'-0"3 THIRD FLOOR T.O.S. 56 ROOF VENTILATION NOTES: (CRC R806) 1.ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE ENTRANCE OF RAIN OR SNOW. VENTILATION OPENINGS SHALL HAVE AT LEAST DIM. OF 1/16" MIN. AND 1/4" MAX. VENTILATION OPENINGS HAVING A LEAST DIMENSION LARGER THAN 1/4" SHALL BE PROVIDED W/. CORROSION-RESISTANT WIRE CLOTH SCREENING, HARDWARE CLOTH, OR SIMILAR MATERIAL WITH OPENINGS HAVING A LEAST DIM. OF 1/16" MIN. AND 1/4" MAX. OPENINGS IN ROOF FRAMING MEMBERS SHALL CONFORM TO THE REQ'TS. OF CRC R802.7. REQUIRED VENTILATION OPENINGS SHALL OPEN DIRECTLY TO THE OUTSIDE AIR. 2. THE NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1/150 OF THE AREA OF THE SPACE VENTILATED. THE NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1/300 IF ONE OR MORE OF THE FOLLOWING ARE MET; 1. IN CLIMATE ZONES 14 & 16, A CLASS I OR II VAPOR RETARDER IS INSTALLED ON THE WARM-IN-WINTER SIDE OF THE CEILING. 2. AT LEAST 40% AND MORE THAN 50% OF THE REQUIRED VENTILATING ARE IS PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE ATTIC OR RAFTER SPACE. UPPER VENTILATORS SHALL BE LOCATED NO MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE, MEASURED VERTICALLY, WITH THE BALANCE OF TEH REQUIRED VANTILATION PROVIDED BY EAVE OR CORNICE VENTS. WHERE THE LOCATION OF WALL OR ROOF FRAMING MEMBERS CONFLICTS WITH THE INSTALLATION OF UPPER VENTILATORS, INSTALLATION MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST OF THE SPACE SHALL BE PERMITTED. 3. WHERE EAVE OR CORNICE VENTS ARE INSTALLED, INSULATION SHALL NOT BLOCK THE FREE FLOW OF AIR. A MIN. OF A 1" SPACE SHALL BE PROVIDED BETWEEN THE INSULATION AND THE ROOF SHT'G. AND AT THE LOCATION OF THE VENT. 4. VENTILATORS SHALL BE INSTALLED IN ACCORDANCE WITH MFR'G.'S INSTALLATION INSTRUCTIONS. INSTALLATION OF VENTILATORS IN ROOF SYSTEMS SHALL BE IN ACCORDANCE W/. THE REQ'TS. OF SECTION R903. INSTALLATION OF VENTILATORS IN WALL SYSTEMS SHALL BE IN ACCORDANCE W/. THE REQ'TS. OF SECTION R703.1. 5. UNVENTED ATTIC ASSEMBLIES (SPACES BETWEEN THE CEILING JOISTS OF THE TOP STORY AND THE ROOF RAFTERS) AND UNVENTED ENCLOSED RAFTER ASSEMBLIES (SPACES BETWEEN CEILINGS THAT ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF FRAMING MEMBER/RAFTERS AND THE STRUCTURAL ROOF SHT'G. AT THE TOP OF THE ROOF FRAMING MEMBERS/RAFTERS) SHALL BE PERMITTED IF ALL OF THE FOLLOWING CONDITIONS ARE MET: 1. THE UNVENTED ATTIC SPACE IS COMPLETELY CONTAINED WITHIN THE BUILDING THERMAL ENVELOPE. 2. NO INTERIOR CLASS I VAPOR RETARDERS ARE INSTALLED ON THE CEILING SIDE (ATTIC FLOOR) OF THE UNVENTED ATTIC ASSEMBLY OR ON THE CEILING SIDE OF THE UNVENTED ENCLOSED RAFTER ASEEMBLY. 3. WHERE WOOD SHINGLES OF SHAKES ARE USED, A MIN. 1/4" VENTED AIR SPACE SEPARATES THE SHINGLES OR SHAKES AND THE ROOFING UNDERLAYMENT ABOVE THE STRUCTURAL SHT'G. 4. IN CALIFORNIA CLIMATE ZONES 14 & 16, ANY AIR- IMPERMEABLE INSULATION SHALL BE A CLASS II VAPOR RETARDER, OR SHALL HAVE A CLASS III VAPOR RETARDER COATING OR COVERING IN DIRECT CONTACT W/. THE UNDERSIDE OF THE INSULATION (SEE TITLE 24, PART 6, FIG. 100.1-A) 5. EITHER ITEMS 5.1, 5.2 OR 5.3 SHALL BE MET, DEPENDING ON THE AIR PERMEABILITY OF THE INSULATION DIRECTLY UNDER THE STRUCTURAL ROOF SHT'G. (NO INSULATION SHALL BE REQ'D. WHEN ROOF TILES, WOOD SHINGLES OR WOOD SHAKES, OR ANY OTHER ROOFING SYSTEM USING BATTENS AND NO CONT. UNDERLAYMENT IS INSTALLED. A CONT. LAYER SHALL BE CONSIDERED TO EXIST IF SHT'G., ROOFING PAPER OR ANY CONT. LAYER WHICH HAS A PERM RATE OF NO MORE THAN ONE PERM UNDER THE DRY CUP METHOD.); 5.1. AIR-IMPERMEABLE INSULATION ONLY. INSULATION SHALL BE APPLIED IN DIRECT CONTACT W/. THE UNDERSIDE OF THE STRUCTURAL ROOF SHT'G. 5.2. AIR-PERMEABLE INSULATION ONLY. IN ADDITION TO THE AIR-PERMEABLE INSULATION INSTALLED DIRECTLY BELOW THE STRUCTURAL SHT'G., RIDGE BOARD OR SHEET INSULATION W/. AN R-VALUE OR R-4 SHALL BE INSTALLED DIRECTLY ABOVE THE STRUCTURAL ROOF SHT'G. FOR CONDENSATION CONTROL. 5.3. AIR-IMPERMEABLE AND AIR-PERMEABLE INSULATION. THE AIR-IMPERMEABLE INSULATION SHALL BE APPLIED IN DIRECT CONTACT W/. THE UNDERSIDE OF THE STRUCTURAL ROOF SHT'G. FOR CONDENSATION CONTROL. THE AIR-PERMEABLE INSULATION SHALL BE INSTALLED DIRECTLY UNDER THE AIR-PERMEABLE INSULATION. 5.4. WHERE PREFORMED INSULATION BOARD IS USED AS THE AIR IMPERMEABLE INSULATION LAYER, IT SHALL BE SEALED AT THE PERIMETER OF EACH INDIVIDUAL SHEET INTERIOR SURFACE TO FORM A CONT. LAYER. FILLED REGION INDICATES ATTIC SPACE-REF. ATTIC VENTILATION CALCS. ROOF PLAN LEGEND A-4.03 A-4.0 A-4.0 A-4.0 4 1 2 2 A-5.0 2 A-5.0 1 A-5.0 1 A-5.0 VIEW DECK ROOF DECKBELOW REF. A-2.0 3:123:12 3:123:123:123:12 3:12 3:12 3:123:123:12 37.87' 37.90' 37.89'37.89' 37.95' 1 1 1 23%3%3%3%2 13 4 4 3F.O.F.3' - 6 1/4"5 3/4"F.O.F. 25' - 8 3/8"5 3/4" F.O.F. 26' - 2 3/8"5 3/4"F.O.F.2' - 8 1/4"5 3/4"6 1/4" F.O.F. 28' - 6 1/2"6 1/4"F.O.F.14' - 3 5/8"F.O.F. 34' - 6 3/4"F.O.F.7' - 3 5/8"5 3/4"5 3/4" F.O.F. 39' - 2 3/4" 2 21 1 3 4 5 5 5 (HT. CERT. REQ'D.) (HT. CERT. REQ'D.) (HT. CERT. REQ'D.) (HT. CERT. REQ'D.) (HT. CERT. REQ'D.) (HT. CERT. REQ'D.) 32.67' T.W. 32.67' T.R. 32.67' T.R.33.00' T.W. 32.83' T.R. 33.00' T.W. 32.67' T.R.3:123:12 6 6 6 7 32.83' T.R. (HT. CERT. REQ'D.) (HT. CERT. REQ'D.) 37.91' 3:12 3:12 3:12 3:12 BELOW REF. A-2.0 2x ROOF RAFTER (PER STRUCT.) INTERIOR FINISH (PER PLANS, WHERE OCCURS) AIR-PERMEABLE INSULATION (PER PLANS) MIN. 30# ROOF FELT-(2) LAYERS GAF VERSASHIELD UNDERLAYMENT 15/32" CDX PLYWD. SHT'G. MIN. (REF. STRUCT) FASTENERS PER MFGR. INSTRUCTIONS 12 SLOPE PER PLAN STANDING SEAM METAL (ZINC OR EQUIV.) -REF. MAT. SCHED. A/A-5, CLASS 'A' ASSY. TYP.6" - 10"6" MIN. DOUBLE FOLD 3/4" LOCK, ALT. METHOD CLEATS @ 18" O.C. MAX. CONT. LOCK STRIP, SOLDERED ARCH. TO APPV. 12"-16"1-1/2" HIGHVALLEY DETAIL PRODUCT LISTING: ICC # ESR-2048, CB-150 UNVENTED ENCLOSED RAFTER ASSEMBLY NOTE: NO INTERIOR CLASS I VAPOR RETARDER SHALL BE INSTALLED ON THE CEILING SIDE (ATTIC FLOOR) OF THE UNVENTED ATTIC ASSEMBLY OR ON THE CEILING SIDE OF THE UNVENTED ENCLOSED ROOF FRAMING ASSEMBLY. 1/4" DENSGLASS OR EQUIV. JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONSOWNER INFORMATION:PROJECT NAME STATUS These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT A-3.0 03/22/2019 2018-30ROOF PLANMODERN BAY FRONT MODERN BAY FRONTSOUTH BAYFRONTWATERPOINTE, LLCGARRETT CALACCI610 NEWPORT CENTERDRIVE, SUITE 890,NEWPORT BEACH, CA92660CDP -FIRST CHECK 402 S BAY FRONTNEWPORT BEACH, CA 92662Designer KEYNOTE LEGEND 1 ROOF - STANDING SEAM METAL W/. SS. METAL ZINC FINISH - REF. MAT. SCHED. A-4.0 & DTL. 2/A-3.0 2 CRICKET - SLOPE 2% MIN., REF. ROOF PLAN A-4 3 METAL GUTTER - KYNAR FINISH OR EQUIV., SHAPE AS SEL. - PROVIDE SHOP DWGS. TO ARCH. PRIOR TO FAB. 4 ROOF FASCIA - EAVE AS DIMENSIONED (REF. ROOF PLAN & RCP FOR DETAILS) 5 LINE OF WALLS BELOW 6 OUTLINE OF EXISTING BUILDING - TO BE DEMOLISHED 7 EXTERIOR GLASS GUARD - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTLS. 13/AD-1 1/4" = 1'-0"1 ROOF PLAN NOTE:ALL DIMS. ARE TO FACE OF STUD (F.O.S.) OR FACE OF SHT'G. (F.O.S.) TYP. U.N.O. EAVE DIMS. ARE FROM FACE OF SHT'G. TO FACE OF FINISH FASCIA A NO. REVISION DATE 1 1/2" = 1'-0"2 METAL ROOFING DETAIL TRUE NORTH PROJECT NORTH 57 WINDOWS & DOORS: AUTHORIZED DEALER (PRODUCTS LISTED BELOW) SUPPLIER: ASSOCIATED BUILDING SUPPLY ADDRESS: STONE MILL DESIGN CENTER 2915 RED HILL AVE., SUITE F104, COSTA MESA, CA 92626 CONTACT: JOE YOUNAN PHONE: 949-872-3319 FAX: 206-666-2150 EMAIL: JYOUNAN@ABSSOCAL.COM WEB: WWW.ASSOCIATEDBUILDINGSUPPLY.COM ALUMINUM CLAD WINDOWS & PATIO DOORS MANUFACTURER: JELD-WEN WINDOWS & DOORS PRODUCT: CUSTOM COLLECTION ADDRESS: 3250 LAKEPORT BLVD. P.O. BOX 1329; KLAMATH FALLS, OREGON 97601 PHONE: 541-885-7412 OR 800-535-3936 FAX: 541-884-3331 WEB: WWW.JELD-WEN.COM MULTI SLIDE DOORS & STOREFRONT MANUFACTURER: WESTERN WINDOW SYSTEMS PRODUCT: SERIES 600 & STOREFRONT SYSTEMS ADDRESS: 5621 S. 25TH ST., PHOENIX, AZ 85040 PHONE: 877.268.1300 WEB: WWW.WESTERNWINDOWSYSTEMS.COM GUTTERS: GARAGE DOORS: SUPPLIER:RANCH HOUSE DOORS WWW.RANCHHOUSEDOORS.COM STYLE: CUSTOM MATERIAL: CUSTOM BUILT, WOOD & GLASS WATERPROOF DECK MEMBRANE: FLASHING & WEATHERSTRIPPING: MATERIAL: METAL -ALUM. PAINTED KYNAR SHAPE: HALF ROUND (5") (VERIFY W/. ARCH.) TUFFLEX POLYMERS 10880 POPLAR AVE. FONTANA, CA P: 909.349.2016 WWW.TUFFLEXPOLYMERS.COM CODE: ICC # ESR-2505 PROVIDE MIN. 24 GUAGE METAL (16 OZ.) SHEETING (TO MATCH) FOR ALL EXTERIOR FLASHING & WEATHERSTRIPPING APPLICATIONS. VERIFY W/. ARCHITECT ANY UNCONVENTIONAL ENVELOPE WATERPROOFING AREAS PRIOR TO INSTALLATION. BRICK VENEER: MANUFACTURER: ELDORADO STONE. LLC 1200 INDUSTRY STREET EVERETT, WA. 98203 P: 425-407-0107 STONE TYPE:CAPISTRANO ADOBE (ARCH. TO VERIFY) COLOR: PAINTED LIGHT GREY, OWNER TO APPV. APPLICATION: RUNNING BOND, RUSTIC GROUT (ARCH. TO APPV.) THICKNESS: 1" -1.5" NOMINAL WEIGHT:LESS THAN 12 LBS. / S.F. APPROVALS: ICC ESR -1215 VERTICAL T&G WOOD SIDING: SPECIES: TBD SIZE: HORIZONTAL, VARYING WIDTHS. TREATMENT: TBD APPLICATION: PER DETAIL 14/AD-1 CODE: N/A METAL ROOFING: ( CLASS 'A' ) MANUFACTURER: CUSTOM-BILT METALS 13940 MAGNOLIA AVE. CHINO, CA 91710 P: 909.664.1500 PRODUCT: STANDING SEAM ZINC ROOFING, CB-150 COLOR: NATURAL ZINC NOTES:USE CONTINUOUS 16" OR 18" PANS -VERIFY W/. ARCH. SIZE & LOC'N. OF SEAMS. (NO TRANSVERSE SEAMS) REF. DTL. 1/A-3 WEIGHT:APPX. 2 PSF. CODE: ICC # ESR-2048, CB-150 CEMENT BASED WOOD SIDING: MANUFACTURER: JAMES HARDIE BUILDING PRODUCTS, INC. 10901 ELM AVENUE FONTANA, CA 92337 P: 909.356.6366 COLOR: PAINTED-DUNN EDWARDS: WHITE APPLICATION: SHIPLAP 6" PLANK CODE: ICC# NER-405 FIRST FLOOR (T.O.S.) 9.00' MAX. RIDGE HEIGHT 38.00' MAX. RIDGE HEIGHT 38.00' MASTER FLOOR PLATE (TYP.) 18.50' MASTER FLOOR T.O.S. (TYP.) 19.58' ROOF PLATE (TYP.) 36.33' ROOF PLATE (TYP.) 36.33' NADV 88 9.00' NADV 88 9.00' MAX FLAT 33.00' MAX FLAT 33.00' THIRD FLOOR PLATE 28.08' THIRD FLOOR PLATE 28.08' THIRD FLOOR T.O.S. 29.17'THIRD FLOOR T.O.S. 29.17' UPPER DECK T.O.S. (TYP.) 29.33' UPPER DECK FLOOR PLATE (TYP.) 28.45' 2 A-5.0 SECOND FLOOR PLATE (TYP.) 17.50' SECOND FLOOR T.O.S. (TYP.) 18.58' GARAGE (T.O.S.) 7.17' 2 2 1 1 14 13 2 3 10 24 23 1 2 7 37.95' 37.87'10' - 4"1' - 1"9' - 6"1' - 1"7' - 2"11' - 5"10' - 7"29' - 0"24' - 0"9' - 6"1' - 1"8' - 6"1' - 1"7' - 2"10' - 7"8' - 10 3/8"10 5/8"9' - 7"2"11 5 4 4 10 7 7 10 11ABV. F.F.42" MIN.ABV. F.F.42" MIN.3 1 3 2 3 :1 2 3:12 3 :1 2 ABV. F.F.42" MIN.ABV. LND.3' - 6"ABV. LND.3' - 6"ABV. LND.3' - 6"3 HD. HT.8' - 0"SILL HT.3' - 0"HD. HT.8' - 0"ABV. F.F.42" MIN.4 4 ABV. F.F.42" MIN.SILL HT.4' - 6"HD. HT.8' - 0"SILL HT.3' - 6"32.67'33.00' 9 8 8 (HT. CERT REQ'D.) (HT. CERT REQ'D.)(HT. CERT REQ'D.)(HT. CERT REQ'D.) 7 4 3' - 6"4 3/8"9' - 9"11 12 112 2 FIRST FLOOR (T.O.S.) 9.00' FIRST FLOOR (T.O.S.) 9.00' MAX. RIDGE HEIGHT 38.00' MAX. RIDGE HEIGHT 38.00' MASTER FLOOR PLATE (TYP.) 18.50' MASTER FLOOR PLATE (TYP.) 18.50' MASTER FLOOR T.O.S. (TYP.) 19.58' MASTER FLOOR T.O.S. (TYP.) 19.58' ROOF PLATE (TYP.) 36.33' ROOF PLATE (TYP.) 36.33' NADV 88 9.00'NADV 88 9.00' MAX FLAT 33.00' MAX FLAT 33.00' UPPER DECK T.O.S. (TYP.) 29.33' UPPER DECK T.O.S. (TYP.) 29.33' UPPER DECK FLOOR PLATE (TYP.) 28.45' UPPER DECK FLOOR PLATE (TYP.) 28.45' 1 A-5.0 3/4"3/4"9 6 1ABV. F.F.42" MIN.ABV. F.F.42" MIN.37.90'37.89' 33.00'33.00' 1 1 3 2 4 4 29' - 0"24' - 0"9' - 6"1' - 1"8' - 10 3/8"10 5/8"7' - 0"10' - 7"9' - 9"10 10 12 5 3:12 3 :1 2 7 7 P.L.P.L. (HT. CERT REQ'D.)(HT. CERT REQ'D.)(HT. CERT REQ'D.) (HT. CERT REQ'D.)(HT. CERT REQ'D.) FIRST FLOOR (T.O.S.) 9.00' MAX. RIDGE HEIGHT 38.00' MAX. RIDGE HEIGHT 38.00' MASTER FLOOR PLATE (TYP.) 18.50' MASTER FLOOR T.O.S. (TYP.) 19.58' ROOF PLATE (TYP.) 36.33' ROOF PLATE (TYP.) 36.33' NADV 88 9.00' NADV 88 9.00' MAX FLAT 33.00' MAX FLAT 33.00' THIRD FLOOR PLATE 28.08' THIRD FLOOR PLATE 28.08' THIRD FLOOR T.O.S. 29.17' THIRD FLOOR T.O.S. 29.17' UPPER DECK T.O.S. (TYP.) 29.33' UPPER DECK FLOOR PLATE (TYP.) 28.45' 2 A-5.0 SECOND FLOOR PLATE (TYP.) 17.50' SECOND FLOOR T.O.S. (TYP.) 18.58' GARAGE (T.O.S.) 7.17' 2 2 1 1 22 21 20 898 7 6 5 19 18 17 5 37.89'37.95' 3 :1 2 3:12 7' - 2"1' - 1"9' - 6"1' - 1"10' - 4"10' - 7"11' - 5"1 2 1 6 ABV. F.F.42" MIN.ABV. F.F.42" MIN.ABV. F.F.42" MIN.7 4 4 5 2 8 9 33.00' 7 10 10 11 HD. HT.8' - 0"SILL HT. 3' - 6"HD. HT.8' - 0"SILL HT.3' - 0"7' - 2"1' - 1"8' - 6"1' - 1"9' - 6"10 5/8"8' - 10 3/8"10' - 7"9' - 9"SILL HT.3' - 0"HD. HT.8' - 0"HD. HT.8' - 0"SILL HT.3' - 6"3 :1 2 (HT. CERT REQ'D.)(HT. CERT REQ'D.) (HT. CERT REQ'D.) 32.67'SILL HT.3' - 6"SILL HT.4' - 6"4 2"9' - 7"28 27 26 MAX. RIDGE HEIGHT 38.00' MAX. RIDGE HEIGHT 38.00' ROOF PLATE (TYP.) 36.33' ROOF PLATE (TYP.) 36.33' NADV 88 9.00' NADV 88 9.00' MAX FLAT 33.00' MAX FLAT 33.00' THIRD FLOOR PLATE 28.08' THIRD FLOOR PLATE 28.08' THIRD FLOOR T.O.S. 29.17' THIRD FLOOR T.O.S. 29.17'1' - 1"7' - 2"1' - 1"SECOND FLOOR PLATE (TYP.) 17.50' SECOND FLOOR PLATE (TYP.) 17.50' SECOND FLOOR T.O.S. (TYP.) 18.58' SECOND FLOOR T.O.S. (TYP.) 18.58' GARAGE (T.O.S.) 7.17' GARAGE (T.O.S.) 7.17' 1 A-5.0 12 10 16 15 8 ABV. F.F.42" MIN.10' - 4"1' - 1"9' - 6"1' - 1"7' - 2"11' - 5"10' - 7"29' - 0"24' - 0"32.67'32.67' 37.95' 4 1 2 3 2 4 5 HD. HT.8' - 0"SILL HT.4' - 6"7 9 8 4 P.L.P.L. (HT. CERT REQ'D.)(HT. CERT REQ'D.) JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONSOWNER INFORMATION:PROJECT NAME STATUS These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT A-4.0 03/22/2019 2018-30EXTERIOR ELEVATIONS &MATERIAL SCHEDULEMODERN BAY FRONT MODERN BAY FRONTSOUTH BAYFRONTWATERPOINTE, LLCGARRETT CALACCI610 NEWPORT CENTERDRIVE, SUITE 890,NEWPORT BEACH, CA92660CDP -FIRST CHECK 402 S BAY FRONTNEWPORT BEACH, CA 92662Designer KEYNOTE LEGEND 1 BRICK VENEER - REF. DTL. 8/AD-1 & MATERIAL SCHEDULE A-4.0. 2 WOOD SIDING - REF. DTL. 5/AD-1 & MATERIAL SCHEDULE A-4 3 VERTICAL WOOD SIDING, SEE MATERIAL SCHEDULE A-4.0 AND DTL 8/AD-1. 4 EXTERIOR GLASS GUARD - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTLS. 13/AD-1 5 ROOF - STANDING SEAM METAL W/. SS. METAL ZINC FINISH - REF. MAT. SCHED. A-4.0 & DTL. 2/A-3.0 6 MAIN SERVICE PANEL, 400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION) - VERIFY LOC'N. W/. SO. CA. EDISON 7 STRUCTURAL STEEL BEAM - REF. STRUCT. DWGS. 8 METAL GUTTER - KYNAR FINISH OR EQUIV., SHAPE AS SEL. - PROVIDE SHOP DWGS. TO ARCH. PRIOR TO FAB. 9 ROOF FASCIA - EAVE AS DIMENSIONED (REF. ROOF PLAN & RCP FOR DETAILS) 10 EXTERIOR WALL MOUNTED LIGHT FIXTURE (HIGH EFFICIENCY) SIZE AS SEL., DOWNLIGHT TYP. U.N.O. 11 STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT CANDLE (CBC 1205.4) REF. DTL. 3/AD-1 12 BBQ, AS SEL. - PROVIDE NATURAL GAS MATERIAL SCHEDULEA 1/4" = 1'-0"4 LEFT SIDE ELEVATION NOTE: REF. ROOF PLAN (A-3.0) FOR ALL PLATE HTS. & RIDGE HTS. NOTE: FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT LABELS. NO. REVISION DATE 1 Revision 1 Date 1 1/4" = 1'-0"1 FRONT ELEVATION 1/4" = 1'-0"2 RIGHT SIDE ELEVATION 1/4" = 1'-0"3 REAR ELEVATION 58 FIREBLOCKING AND DRAFTSTOPPING SHALL BE INSTALLED TO CUT OFF ALL CONCEALED DRAFT OPENINGS (BOTH VERTICAL AND HORIZONTAL) AND SHALL FORM AN EFFECTIVE BARRIER BETWEEN FLOORS, BETWEEN A TOP STORY AND A ROOF OR ATTIC SPACE, AND SHALL SUBDIVIDE ATTIC SPACES, CONCEALED ROOF SPACES AND FLOOR-CEILING ASSEMBLIES. THE INTEGRITY OF ALL FIRE BLOCKS AND DRAFT STOPS SHALL BE MAINTAINED. FIRE BLOCKS. FIREBLOCKING SHALL BE PROVIDED IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES, AT THE CEILING AND FLOOR LEVELS AND AT 10-FOOT INTERVALS BOTH VERTICAL AND HORIZONTAL. FIRE BLOCK CONSTRUCTION. FIREBLOCKING SHALL CONSIST OF 2 INCHES NOMINAL LUMBER. FIRE BLOCKS MAY ALSO BE OF GYPSUM BOARD, CEMENT FIBER BOARD, BATTS OR BLANKETS OF MINERAL OR GLASS FIBER, OR OTHER APPROVED MATERIALS INSTALLED IN SUCH A MANNER AS TO BE SECURELY RETAINED IN PLACE. LOOSE- FILL INSULATION MATERIAL SHALL NOT BE USED. WALLS HAVING PARALLEL OR STAGGERED STUDS FOR SOUND-TRANSMISSION CONTROL SHALL HAVE FIRE BLOCKS OF BATTS OR BLANKETS OF MINERAL OR GLASS FIBER OR OTHER APPROVED FLEXIBLE MATERIALS. DRAFT STOPS. DRAFTSTOPPING SHALL BE PROVIDED IN THE LOCATIONS SET FORTH IN THIS SECTION. FLOOR-CEILING ASSEMBLIES. DRAFT STOPS SHALL BE INSTALLED IN FLOOR-CEILING ASSEMBLIES OF THE BUILDING. SUCH DRAFT STOPS SHALL BE IN LINE WITH WALLS SEPARATING INDIVIDUAL DWELLING UNITS FROM EACH OTHER AND FROM OTHER AREAS. ATTICS. DRAFT STOPS SHALL BE INSTALLED IN THE ATTICS, MANSARDS, OVERHANGS, FALSE FRONTS SET OUT FROM WALLS AND SIMILAR CONCEALED SPACES OF THIS BUILDING. SUCH DRAFT STOPS SHALL BE ABOVE AND IN LINE WITH THE WALLS SEPARATING INDIVIDUAL DWELLING UNITS FROM EACH OTHER AND FROM OTHER USES. DRAFT STOP CONSTRUCTION. DRAFTSTOPPING MATERIALS SHALL NOT BE LESS THAN ½-INCH GYPSUM BOARD, 3/8-INCH WOOD STRUCTURAL PANEL, 3/8-INCH TYPE 2-M PARTICLEBOARD OR OTHER APPROVED MATERIALS ADEQUATELY SUPPORTED. OPENINGS IN THE PARTITIONS SHALL BE PROTECTED BY SELF-CLOSING DOORS WITH AUTOMATIC LATCHES CONSTRUCTED AS REQUIRED FOR THE PARTITIONS. FIRE-BLOCKING & DRAFT-STOP NOTE INSULATION SCHEDULE: EXTERIOR WALL: 2 x 4 CONST. = R-19 MIN. 2 x 6 CONST. OR LARGER =R-19 RAISED FLOOR:R-30 MIN. ROOF:R-30 (REF. T-24 REPORT FOR MORE INFORMATION) NOTE: PROVIDE BID FOR INSULATION OF ENTIRE HOME NEW WALL -2 x 6 STUDS @ 16" O.C. U.N.O. NEW WALL -2 x 4 STUDS @ 16" O.C. U.N.O. WALL W/. STONE VENEER -2x STUDS @ 16" O.C. U.N.O. CONCRETE RETAINING WALL -REF. STRUCTURAL SEPARATION LEGEND EXTERIOR FIRE RATED PARTITION REF. DTL. 5/AD-1 1 HR. FIRE RATED PARTITION REF. DTL. 7/AD-1 1 HR. FLOOR SYSTEM REF. DTL. 7/AD-1 INSULATED SYS. REF. INSULATION SCHEDULE THIS SHT. B FIRST FLOOR (T.O.S.) 9.00' MAX. RIDGE HEIGHT 38.00' MAX. RIDGE HEIGHT 38.00' MASTER FLOOR PLATE (TYP.) 18.50' MASTER FLOOR T.O.S. (TYP.) 19.58' ROOF PLATE (TYP.) 36.33' ROOF PLATE (TYP.) 36.33' NADV 88 9.00' NADV 88 9.00' MAX FLAT 33.00' MAX FLAT 33.00' THIRD FLOOR PLATE 28.08' THIRD FLOOR PLATE 28.08' THIRD FLOOR T.O.S. 29.17'THIRD FLOOR T.O.S. 29.17' UPPER DECK T.O.S. (TYP.) 29.33' UPPER DECK FLOOR PLATE (TYP.) 28.45' 2 A-5.0 SECOND FLOOR PLATE (TYP.) 17.50' SECOND FLOOR T.O.S. (TYP.) 18.58' GARAGE (T.O.S.) 7.17' 2 2 1 1 1' - 0"8' - 6"BONUS ROOMROOF DECK VIEW DECK MASTER SUITE M. BALCONY PATIO GREAT ROOM KITCHENFOYER 2-CAR GARAGE BEDROOM #2 BALCONY 25 5 6 5 15 2122 11 987 21 22 9' - 6"1' - 1"8' - 6"1' - 1"7' - 2"10' - 7"9' - 7"2"8' - 10 3/8"10 5/8"9' - 9"ABV. F.F.42" MIN.ABV. F.F.42" MIN.3 :1 2 3:12 3:12 ABV. F.F.42" MIN.2 2 1 3 4 SLOPE PER CIVIL 2% MIN.ABV. F.F.42" MIN.2% MIN.2% MIN.2% MIN.2% MIN. 2% MIN. 9 9 10 2 2 9 11 12 27 28 FIRST FLOOR (T.O.S.) 9.00' FIRST FLOOR (T.O.S.) 9.00' MAX. RIDGE HEIGHT 38.00' MAX. RIDGE HEIGHT 38.00' MASTER FLOOR PLATE (TYP.) 18.50' MASTER FLOOR PLATE (TYP.) 18.50' MASTER FLOOR T.O.S. (TYP.) 19.58' MASTER FLOOR T.O.S. (TYP.) 19.58' ROOF PLATE (TYP.) 36.33' ROOF PLATE (TYP.) 36.33' NADV 88 9.00' NADV 88 9.00' MAX FLAT 33.00' MAX FLAT 33.00' THIRD FLOOR PLATE 28.08' THIRD FLOOR PLATE 28.08' THIRD FLOOR T.O.S. 29.17' THIRD FLOOR T.O.S. 29.17' 1 A-5.0 9' - 6"1' - 1"8' - 6"1' - 1"7' - 2"3 :1 2 3:12 3 :1 2 3:12 3 :1 2 3:12 BONUS ROOM STAIRS STAIRSMASTER BATH KITCHEN STAIRS/ BAR 18 17 9 110' - 7"9' - 7"ABV. F.F.42" MIN.TYP.7 5/8"TYP. 11" 1 5 1 6 7 7 8 P.L.P.L. 1 2 1/4" Name Elevation A101 1 SIM 101 1i ? 1 1 A101 SIM R @ 7 1/2"20 1i SECTION INDICATOR CALL-OUT TAG ELEVATION INDICATOR KEYNOTE TAG -REF. KEYNOTE LEGEND THIS SHEET WINDOW TAG -REF. SHEET A-8 DOOR TAG -REF. SHEET A-8 WALL TAG REVISION FLAG STAIR TAG (NO. OF RISER & HEIGHT) ANNOTATION LEGENDA JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONSOWNER INFORMATION:PROJECT NAME STATUS These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT A-5.0 03/22/2019 2018-30BUILDING SECTIONSMODERN BAY FRONT MODERN BAY FRONTSOUTH BAYFRONTWATERPOINTE, LLCGARRETT CALACCI610 NEWPORT CENTERDRIVE, SUITE 890,NEWPORT BEACH, CA92660CDP -FIRST CHECK 402 S BAY FRONTNEWPORT BEACH, CA 92662Designer KEYNOTE LEGEND 1 STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT CANDLE (CBC 1205.4) REF. DTL. 3/AD-1 2 EXTERIOR GLASS GUARD - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTLS. 13/AD-1 3 KITCHEN SINK - AS SELECTED 4 VEHICLE - MINIMUM PARKING DIMENSIONS ON PLANS 5 INTERIOR HANDRAIL - 34" - 38" ABV. NOSING (36" TYP. U.N.O.), REF. DTLS. 4 & 9/AD-1 6 CUSTOM BUILT KITCHEN ISLAND PER OWNER & ARCH. 7 FLOOR JOISTS - REF. STRUCT. 8 INTERIOR GUARD - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTLS. 4 & 9/AD-1 9 STRUCTURAL STEEL BEAM - REF. STRUCT. DWGS. 10 EXTERIOR WALL MOUNTED LIGHT FIXTURE (HIGH EFFICIENCY) SIZE AS SEL., DOWNLIGHT TYP. U.N.O. 11 FIRE PIT LOC'N., PROVIDE GAS AS NEEDED 12 WOOD SIDING - REF. DTL. 5/AD-1 & MATERIAL SCHEDULE A-4 NO. REVISION DATE 1/4" = 1'-0"1 LONGITUDINAL SECTION 1/4" = 1'-0"2 TRANSVERSE SECTION 59 FOUNDATION NOTES:ALL DIMENSIONS SHALL BE VERIFIED WITH THE ARCHITECTS DRAWINGS ANY DISCREPANCIES SHALL BE RESOLVED PRIOR TO COMMENCING OF WORK. 1. ALL BEARING & SHEAR WALLS ARE TO BE SECURED WITH 5/8" DIAMETER BY 10" LONG ANCHOR BOLTS EMBEDDED AT LEAST 7" INTO CONCRETE WITH A MAXIMUM SPACING OF 48" O.C. U.N.O. THERE SHALL BE A MINIMUM OF TWO ANCHORS PER PIECE OF FOUNDATION PLATE WITH ONE BOLT LOCATED WITHIN 12" MAX. & 4-1/2" MIN. OF EA. END OF EA. PIECE. SHEAR WALLS BOLTS SHALL HAVE A PROPERLY SIZED NUT AND A 3"x3"x.229" WASHER. THE WASHER MAY BE SLOT CUT PROVIDED A STANDARD CUT WASHER IS PROVIDE BETWEEN THE NUT AND WASHER. WASHER TO BE INSTALLED WITHIN A 1/2" OF THE SHEATHED SIDE OF THE PLATE. A STANDARD CUT WASHER MAY BE USED AT NON-SHEAR WALL LOCATIONS. 2. FOR ALL INTERIOR NON-SHEAR WALLS USE SIMPSON 0.145" DIAMETERx 3" LONG PDP POWDER ACTUATED ANCHORS @ 24" O.C. (ESR #2138 OR EQUAL)3. INSTALL ALL SIMPSON (OR APPROVED EQUAL) FOUNDATION HARDWARE PER MANUFACTURERS RECOMMENDATIONS. DEEPEN FOOTING WHERE NECESSARY TO PROVIDE ANCHOR EMBEDMENT AT HOLDOWN LOCATIONS. 4. ALL WOOD BEARING ON CONCRETE OR MASONRY SHALL BE PRESSURE TREATED DOUG FIR OR REDWOOD WITH SODIUM BORATE (SBX) OR DISODIUM OCTABORATE TETRAHYDRATE (DOT).NOTE:WHEN REQUIRED BY LOCAL BUILDING DEPARTMENT ALL ANCHOR BOLTS AND HOLDOWN BOLTS TO BE SET IN PLACE PRIOR TO CITY FOUNDATION INSPECTIONSOIL INFORMATION:1. FOUNDATION SIZES, DEPTHS, AND REINFORCEMENT ARE AS RECOMMENDED WITHIN THE OWNER/DEVELOPER'S SOILS ENGINEERS REPORT. SOILS ENGINEER TO PROVIDE FOUNDATION INSPECTOR AS OUTLINED IN LATEST SOIL REPORT. 2. OWNER/DEVELOPER AND SUBCONTRACTORS ARE TO REVIEW THE SOILS REPORT PRIOR TO COMMENCING CONSTRUCTION. IT IS THE RESPONSIBILITY OF THE OWNER, DEVELOPER AND SUBCONTRACTOR TO VERIFY THAT THE REPORT DATE ABOVE IS CURRENT AND PLAN REQUIREMENTS ARE CONSISTANT WITH ANY UPDATED SOIL REPORTS. ESI/FME IS TO BE SUPPLIED WITH ALL UPDATED REPORTS.15" WIDE x 24" DEEP FTG.W/ 2-#5 TOP & BOTTOM CONT.ANCHOR BOLT LEGEND:SLAB: 5" THK. W/#4 BARS @ 12" O/C E/W @ MIDDLE NEW CONSTRUCTION WITH SLAB ON GRADE SHALL INSTALL A CAPILLARY BREAK IN COMPLIANCE WITH CG 4.505.2.1 WITH 2-INCH THICK LAYER OF SAND OVER A 15 MIL VAPOR BARRIER COMPLIANT WITH ASTM E 1745 OVER A 4-INCH THICK BASE OF 1/2-INCH OR LARGER CLEAN AGGREGATE AND A CONCRETE MIX DESIGN WHICH WILL ADDRESS BLEEDING, SHRINKAGE, AND CURLING. (FOR ADDITIONAL INFORMATION, SEE AMERICAN CONCRETE INSTITUTE, ACI 302.OR-06)AB48 : 5/8" DIA. X 12" ANCHOR BOLTS AT 48" O.C. AB40 : 5/8" DIA. X 12" ANCHOR BOLTS AT 40" O.C. AB32 : 5/8" DIA. X 12" ANCHOR BOLTS AT 32" O.C. AB24 : 5/8" DIA. X 12" ANCHOR BOLTS AT 24" O.C. AB16 : 5/8" DIA. X 12" ANCHOR BOLTS AT 16" O.C. AB 8 : 5/8" DIA. X 12" ANCHOR BOLTS AT 8" O.C. 2AB : (2) 5/8" DIA X 12" ANCHOR BOLTS. 3AB : (3) 5/8" DIA. x 12" ANCHOR BOLTS. 2-#4 : PROVIDE A TOTAL OF 2 #4 AT TOP AND 2 #4 AT BOTTOM OF FOOTING, 3' PAST POSTS. 3-#4 : PROVIDE A TOTAL OF 3 #4 AT TOP AND 3 #4 AT BOTTOM OF FOOTING, 3' PAST POSTS. HTT4 : (1) SIMPSON HTT4 PER POST. HTT5 : (1) SIMPSON HTT5 PER POST. HDU2 : (1) SIMPSON HDU2-SDS2.5 PER POST. HDU5 : (1) SIMPSON HDU5-SDS2.5 PER POST. HDU8 : (1) SIMPSON HDU8-SDS2.5 PER POST. HDQ8 : (1) SIMPSON HDQ8-SDS3 PER POST. HDU11 : (1) SIMPSON HDU11-SDS2.5 PER POST. HDU14 : (1) SIMPSON HDU14-SDS2.5 PER POSTGRADE BEAM PER PLANWIDEN AT HARDY FRAME AS REQUIREDSEE SHEET 'HFX1' FOR SHEAR TIE SPACINGGREAT ROOMPATIODININGKITCHENSTAIRS/ BARENTRYFOYERPOWDER2-CAR GARAGEELEV.PANTRYSCALE: 1/4" = 1'-0"FOUNDATION PLAN1FD115" WIDE x 24" DEEPGRADE BEAMW/ (2) #5 TOP & BOTTOM1FD11FD11FD15FD14FD110FD13FD13FD13FD1.A1' - 9"2' - 6"MIN.1' - 10"MIN.11"MIN.11"5FD1.B.BMIN.1' - 10"MIN.11"MIN.11"2' - 6"1' - 9"2' - 6"1' - 9"MIN.1' - 10"MIN.11"MIN.11"15" WIDE x 24" DEEPGRADE BEAMW/ (2) #5 TOP & BOTTOMLATERAL SHEAR NOTES:(2016 CBC, SDPWS-2015 ; SEISMIC DESIGN CATEGORY D & E) (TABLE 4.3A, AFPA SDPWS-2015) FRAMING MEMBERS VERTICAL: DOUGLAS FIR-LARCH AT 16" O.C10. 1/2" WOOD STRUCTURAL PANEL WITH 8d COMMON NAILS AT 6" O.C AT EDGES AND 12" O.C. AT FIELD . .....260 PLF11. 1/2" WOOD STRUCTURAL PANEL WITH 8d COMMON NAILS AT 4" O.C AT EDGES AND 12" O.C. AT FIELD ......350 PLF12. 1/2" WOOD STRUCTURAL PANEL WITH 8d COMMON NAILS AT 3" O.C AT EDGES AND 12" O.C. AT FIELD ......490 PLF13. 1/2" WOOD STRUCTURAL PANEL WITH 8d COMMON NAILS AT 2" O.C AT EDGES AND 12" O.C. AT FIELD ......640 PLF14. 1/2" (OR 15/32) WOOD STRUCTURAL PANEL WITH 10d COMMON NAILS AT 2" O.C AT EDGES AND 12" O.C. AT FIELD ......770 PLF15. 1/2" (OR 15/32) STRUCT. I WOOD PANEL WITH 10d COMMON NAILS AT 2" O.C AT EDGES AND 12" O.C. AT FIELD ......870 PLF# FRAMING MEMBERS HORIZONTAL: DOUGLAS FIR-LARCH (3/8" @ CEILING LDS, 15/32 @ ROOF SHEATHING: AT 24" O.C20. BLOCKED PLYWOOD DIAPHRAGM WITH 3/8" WOOD STRUCTURAL PANEL AND 8d COMMON NAILS AT 6" O.C. AT BOUNDRIES, 6" AT CENTER AND 10" AT FIELD .....240 PLF21. BLOCKED PLYWOOD DIAPHRAGM WITH 3/8" WOOD STRUCTURAL PANEL AND 8d COMMON NAILS AT 4" O.C. AT BOUNDRIES, 6" AT CENTER AND 10" AT FIELD .....320 PLF22. BLOCKED PLYWOOD DIAPHRAGM WITH 3/8" WOOD STRUCTURAL PANEL AND 8d COMMON NAILS AT 2.5" O.C. STAGG.AT BOUNDRIES, 4" AT CENTER AND 10" AT FIELD .....480 PLF23. BLOCKED PLYWOOD DIAPHRAGM WITH 3/8" WOOD STRUCTURAL PANEL AND 8d COMMON NAILS AT 2" O.C. STAGG.AT BOUNDRIES, 3" AT CENTER AND 10" AT FIELD .....545 PLF# FRAMING MEMBERS HORIZONTAL: DOUGLAS FIR-LARCH AT 16" O.C24. BLOCKED PLYWOOD DIAPHRAGM WITH 19/32" WOOD STRUCTURAL PANEL AND 10d COMMON NAILS AT 6" O.C. AT BOUNDRIES, 6" AT EDGES AND 10" AT FIELD .....320 PLF25. BLOCKED PLYWOOD DIAPHRAGM WITH 19/32" WOOD STRUCTURAL PANEL AND 10d COMMON NAILS AT 4" O.C. AT BOUNDRIES, 6" AT EDGES AND 10" AT FIELD .....425 PLF26. BLOCKED PLYWOOD DIAPHRAGM WITH 19/32" WOOD STRUCTURAL PANEL AND 10d COMMON NAILS AT 2.5" O.C. STAGG. AT BOUNDRIES, 6" AT EDGES AND 10" AT FIELD .....640 PLF27. BLOCKED PLYWOOD DIAPHRAGM WITH 19/32" WOOD STRUCTURAL PANEL AND 10d COMMON NAILS AT 2" O.C. STAGG. AT BOUNDRIES, 3" AT EDGES AND 10" AT FIELD .....730 PLF#NOTES:A. WOOD STRUCTURAL PANEL: MATERIAL APPROVED BY APA, PFS/TECO OR PITTSBURG TESTING LABORATORIES THESE VALUES ARE FOR DOUG-FIR LARCH OR SOUTHERN PINE, OTHER LUMBER SPECIES MAY DIFFER IN SHEAR CAPACITIES. B. PROVIDE 2X BLOCKING AT HORIZONTAL WOOD STRUCTURAL PANEL JOINTS. FRAMING AT ADJOINING PANEL EDGES SHALL BE 3X WHEN NAILING IS 2.5" O.C. OR LESS. C. WHERE WOOD STRUCTURAL PANEL IS APPLIED ON BOTH FACES OF WALL AND NAIL SPACING IS LESS THAN 6" O.C, PANEL JOINTS SHALL BE OFFSET TO FALL ON DIFFERENT FRAMING MEMBERS OR FRAMING SHALL BE 3X OR WIDER AND NAILS STAGGERED ON EACH SIDE. D. FOR SHEAR WALLS TO USE THE FOLLOWING: 1) USE 3x MEMBER @ PANEL JOINTS & HORIZONTAL BLOCKING 2) EDGE NAILING SHALL BE STAGGERED E. 10d SHORT BOX NAILS MAY BE USED IN LIEU OF 8d COMMON NAILS @ SHEAR WALLS ONLY. F. REQUIRED STEEL PLATE WASHERS AT SHEAR WALLS ONLY (WHEN ANCHOR BOLTS ARE USED: 3" x 3" x .229" STEEL PLATE WASHERS ARE REQUIRED ON EACH ANCHOR BOLT (SDPWS SECT. 4.3.6.4.3) WASHER MAY BE SLOT CUT PROVIDED A STANDARD CUT WASHER IS PROVIDED BETWEEN THE WASHER AND NUT. WASHER TO BE INSTALLED WITHIN 1/2" OF SHEATHED SIDE OF PLATE. G. A STANDARD CUT WASHER MAY BE USED AT ALL NON-SHEAR WALL LOCATIONS WITH ANCHOR BOLTS. 1215HORIZONTAL: ALL ROOF AND FLOOR SHEATHING TO BE EXPOSURE I OR EXTERIOR ROOF: -JOIST SPACING EQUAL TO OR LESS THAN 24" O.C: 15/32"WOOD STRUCTURAL PANEL PII 32/16, WITH 8d's AT 6" O.C AT EDGES AND BOUNDARIES, 12" O.C FIELD. -HORIZONTAL DIAPHRAGM VALUES FOR 3/8" WOOD STRUCTURAL PANELS MAY BE USED FOR 15/32" WOOD STRUCTURAL PANELS. U.N.O. FLOOR: - JOIST SPACING EQUAL TO OR LESS THAN 16" O.C: 19/32" WOOD STRUCTURAL PANEL T&G SHTG, PII 32/16, w/10d's AT 6" O.C AT EDGES AND BOUNDARIES, 12" O.C FIELD. -JOIST SPACING EQUAL TO OR LESS THAN 20" O.C: 19/32" WOOD STRUCTURAL PANEL T&G SHTG, PII 40/20, w/10d's AT 6" O.C AT EDGES AND BOUNDARIES, 12" O.C FIELD. -JOIST SPACING EQUAL TO OR LESS THAN 24" O.C: 23/32" WOOD STRUCTURAL PANEL T&G SHTG, PII 48/24, w/10d's AT 6" O.C AT EDGES AND BOUNDARIES, 12" O.C FIELD. PANEL EDGES SHALL HAVE APPROVED T&G JOINTS OR SHALL BE SUPPORTED WITH * BLOCKING NOT REQUIRED WHEN LIGHTWEIGHT CONCRETE IS PLACED OVER SUBFLOOR.FRAMING LEGEND:INDICATES SPAN AND DIRECTION OFDECK JOISTS (SLOPED AS REQUIRED)ROOF JOISTS AND RAFTERSINDICATES SPAN AND DIRECTION OFFLOOR JOISTSINDICATES SPAN AND DIRECTION OFCEILING JOISTSINDICATES SPAN AND DIRECTION OFTRUSSESA. 2x6 AT 12" O.C B. 2x6 AT 16" O.C C. 2x6 AT 24" O.C D. 2x8 AT 12" O.C E. 2x8 AT 16" O.C F. 2x8 AT 24" O.C G. 2x10 AT 12" O.C H. 2x10 AT 16" O.C J. 2x10 AT 24" O.C K. (2) 2x10 AT 16" O.C L. 2x12 AT 12" O.C M. 2x12 AT 16" O.C N. 2x12 AT 24" O.C P. (2) 2X12 AT 16" O.CT. TRUSS AT 24" O.CI-JOIST TABLER-I-JOIST @ 16" O.C.I-JOIST @ 12" O.C.I-JOIST @ 19.2" O.C.I-JOIST @ 16" O.C.Z-X-Y-I-JOIST @ 19.2" O.C.I-JOIST @ 16" O.C.I-JOIST @ 12" O.C.I-JOIST @ 19.2" O.C.V-W-S-U-SIZE &MANUFACTURER OPTIONSSPACINGI-JOIST @ 12" O.C.MARKQ-a) 9 1/2" TJI / 230a) 11 7/8" TJI / 360a) 14" TJI / 360##G=L - INDICATES (1) GANGLAM LVL 1.8EGLB - INDICATES GLULAM BEAMM=L - INDICATES (1) MICROLAM 2.0EPSL - INDICATES PARALAM 2.0ELSL - INDICATES TIMBERSTRAND 1.55EE/S - EACH SIDEFL. HT. - FULL HEIGHTALT. - ALTERNATETYP. - TYPICALU.W.A. - UNDER WALL ABOVEL.O.B. - INDICATES LINE OF BLOCKING R.T.R. - RUN TO ROOF'U' - INDICATES 'U' HANGER, U.N.O. - INDICATES 'HU' HANGER, U.N.O. - INDICATES HEADERS AND BEAMS, REFER TO ENGINEERING CALCSNOTE: * APPLY SHEAR PRIOR TO FRAMING OF PERPENDICULAR WALL AND/OR BOX-OUTS. (WHERE APPLICABLE)FRAMING NOTES LEGENDMARK: DESCRIPTIONSPN12: 16d SOLE PLATE NAILING @ 12" O.C.SPN10: 16d SOLE PLATE NAILING @ 10" O.C.SPN8: 16d SOLE PLATE NAILING @ 8" O.C.SPN4: 16d SOLE PLATE NAILING @ 4" O.C.SPN6: 16d SOLE PLATE NAILING @ 6" O.C.SPN3: 16d SOLE PLATE NAILING @ 3" O.C. STAGGEREDSPN2: 16d SOLE PLATE NAILING @ 2" O.C. STAGGEREDSPN=SOLE PLATE NAILINGNAILS= 16d BOXXX - INDICATES LATERAL ENHANCEMENT. WALL NOT CONSIDERED IN LATERAL ANALYSIS. - SHEAR WALL GRID LINE, REFERENCE STRUCTURAL CALCS FASTENERS AND CONNECTORS TO BE GALVANIZED FOR PRESERVATIVE PRESSURE TREATED WOOD.#GREAT ROOMPATIODININGKITCHENSTAIRS/ BARENTRYFOYERPOWDER2-CAR GARAGEELEV.PANTRYSCALE: 1/4" = 1'-0"FIRST FLOOR FRAMING PLANFAX: 714-835-2819PHONE: 714-835-2800STRUCTURAL ENGINEERS,INC.ESI/FMESANTA ANA, CA 927011800 E. 16TH ST. STE BJOB NO.DATEDOCUMENT VALID UPONORIGINAL SIGNATURESHEET NO.REVISIONSOWNER INFORMATION:PROJECT NAMESTATUSS1H047FOUNDATION PLANBAY FRONT PLACEBAY FRONT PLACEGARRETT CALACCI610 NEWPORT CENTERDRIVE, SUITE 890,NEWPORT BEACH, CA92660FIRST SUBMITTAL402 S BAY FRONTNEWPORT BEACH, CA 9266202-28-2019JOB # K04702-28-19NO. DESCRIPTION DATE60