Loading...
HomeMy WebLinkAbout20190426_Plans SITE NAME: CSTAM 02A SITE NUMBER: CRAN RLOS CSTAM 002 atA PROJECT: CRAN/ SMALL CELL/ PICO U S I D: 213733/ FA: 14823064 PACE: MRLOS051929 ERICSSON ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE IF USING 11"x17"PLOT,DRAWING WILL BE HALF SCALE 330 COMMERCE,STE.200 WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES.NOTHING IN THESE PLANS IS TO BE - — IRVINE,CA 92602 CONSTRUCTED TO PERMIT WORK NOT CONFORMING TO THESE CODES. I 1. 2016 CALIFORNIA ADMINISTRATIVE CODE �j CONSTRUCTION D RAW I N G 2. 2016 CALIFORNIA BUILDING CODE m- 3. 2016 CALIFORNIA ELECTRIC CODE at&t 4. 2016 CALIFORNIA MECHANICAL CODE - 5. 2016 CALIFORNIA PLUMBING CODE THE FOLLOWING PARTIES HEREBY APPROVE AND ACCEPT THESE DOCUMENTS&AUTHORIZE 6. 2016 CALIFORNIA FIRE CODE - ! THE SUBCONTRACTOR TO PROCEED WITH THE CONSTRUCTION DESCRIBED HEREIN.ALL 7. ANY LOCAL BUILDING CODE AMENDMENTS TO THE ABOVE _ DOCUMENTS ARE SUBJECT TO REVIEW BY THE LOCAL BUILDING DEPARTMENT&MAY IMPOSE �7 8. CITY/COUNTY ORDINANCES CHANGES OR MODIFICATIONS. M S QU A R E3 HANDICAP REQUIREMENTS: WIRELESS POLE TYPE: (N) CONCRETE LIGHT POLE 1387 CALLE AVANZADO APPROVED BY: INITIALS: DATE CI FA_IL I TY IS UNMANNED AND NOT FOR HUMAN HABITATION.HANDICAPPED ACCESS NOT REQUIRED IN ACCORDANCE WITH CALIFORNIA ADMINISTRATIVE STATE CODE SAN CLEMENTE CA 92673(949)391-6824 PART 2,TITLE 24,CHAPTER 11 B,SECTION 1103B. AT&T RF ENGINEER: CODE COMPLIANCE POLE ID #: 5824 AT&T OPERATIONS: SITE ACQUISITION MANAGER: THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION.A TECHNICIAN WILL LATITUDE/LONGITUDE: 33.61 092/ -1 1 7.8776 PROJECT MANAGER: VISIT THE SITE AS REQUIRED FOR ROUTINE MAINTENANCE.THE PROJECT WILL NOT ZONING VENDOR: DRAWN BY: JEGRESULT IN ANY SIGNIFICANT DISTURBANCE OR EFFECT ON DRAINAGE;NO SANITARY SEWER SERVICE,POTABLE WATER,OR TRASH DISPOSAL IS REQUIRED AND NO LEASING VENDOR:COMMERCIAL SIGNAGE IS NEW. SITE ADDRESS: 190 [CS] NEWPORT CENTER DRIVE CONSTRUCTION MANAGER: °HECKED BY: GENERAL NOTES A/E MANAGER: (SLC5824), NEWPORT BEACH , CA 92660 PROPERTYOWNER: UTILITY MANAGER: 0 Dig Alert AREA MAPS APPROVALS Know whars below. ■ _ _ - 0 c Call before you dig. _ + 1 _ CALIFORNIA SOUTH - ]may * ' Whde Foodr rMlkcl AT&T PROPOSES TO INSTALL A NEW WIRELESS INSTALLATION LOCATED IN THE PUBLIC RIGHT -�-- Call Two Working Days Before You Dig! r 7` ;` /.� n 'r �A�112/US12019 90%CONSTRUCTION �i Fo!+a V Pr OF WAY TO IN)CONCRETE LIGHT POLE.811/800-227-2600 N i t DESCRIPTION � � THE SCOPE WILL CONSIST OF THE FOLLOWING: Q-,.,. tlr, F} � AvWa FaSNon kIalM�} : �n.nq p L,,1,. + 7 t •; a AT&T TO REMOVE (1) EXISTING CITY OF NEWPORT BEACH CONCRETE STREETLIGHT DIG ALERT �� ,� f• F , ; 4 AT&T TO INSTALL (1) 3Z-11"STREETLIGHT ATBT TO INSTALL (4) NEW AT&T REMOTE RADIO UNITS �pF E55rfl� -7 AT&T TO INSTALL (1) NEW AT&T OMNI-DIRECTIONAL ANTENNA AT&T TO INSTALL (1) NEW AT&T EQUIPMENT SHROUD * AT&T TO INSTALL (1) NEW RAYCAP DISCONNECT P PUBLIC/PRIVATE: PUBLIC RIGHT-OF-WAN � _� 5 �:, '' Z(,r '� � 19D[CS1 NEWPORT CENTER SIT ' AT&T TO INSTALL (1) NEW HANDHOLE ❑ �f. ADDRESS: SI s a V YD'I DRIVE(SLC5824), 7. NEWPORT BEACH,CA 92660 LU APPLICANT: AT&T _ ll ADDRESS: 1452 EDINGER USTIN,CA927AVE PROJECT DESCRIPTION TUSTIN,CA 92780 Newpon Bexh pp�� a LATITUDE(NAD 83): 33.61092 t- Cnumry CMb9 � � LONGITUDE(NAD 83): -11718776 LAT/LONG TYPE: NAD-83 r e • ate $ arrx uJ' �[v�� �� GROUND ELEVATION(NAND 88) :110' '1� - max: cv rcaw SHEET NO. SHEET TITLE OF�+�41rCp JURISDICTION: CITY OF NEWPORT BEACH yy�� -F y � e •� CURRENT ZONING: PUBLIC RIGHT OF WAY l• `�' �F :,d T-1 TITLE SHEET _ _ PROPOSED USE: UNMANNED TELECOMMUNICATIONS GN-1 GENERAL NOTES ..+ _ PlUk Lrynry� ? f_ 1L' r •� ' - 3 A-1 SITE PLAN IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY POWER COMPANY: SCE �- ",ri/=7 } �' ARE ACTING UNDER THE DIRECTION OF A LICENSED ADDRESS: 1INNOVATION WAY �„� -' �' �' w .'} ,'.,!I:�•i.[.r+ _ a [� A-2 ELEVATIONS PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. POMONA,CA 91768 - - �. r' C .`. yprinMWi N•xpw:� L'oro.a Od Mar Plaza `• a�• r• µ ` • , _ n S eaacn cupcalnr A3 ELEVATIONS �N 4 y r•ecr;unfree •��r`+sh Nl A-4 SITE IMAGE PROJECT SITE INFORMATION _��' �' [ ` �� I� n D-1 DETAILS .. Y i-rr`• ` . x �. �-, { n 9 .aDiri.4F (pcop lieu^q L ■1"EC D-2 DETAILS SITE ID:CSTAM 02A ��1, S-1 POLE DETAILS 190[CS]NEWPORT CENTER n. !' ^ - rYF } •` ML a .1 4 E-1 ELECTRICAL&GROUNDING DETAILS DRIVE(SLC5824) PROJECT MANAGER: ENGINEER: '- - /..y Linnoo i S M SQUARED WIRELESS M SQUARED WIRELESS •`' Q NEWPORT BEACH,CA,92660 1387 CALLE AVANZADO 1387 CALLE AVANZADO SAN CLEMENTE,CA 92673 SAN CLEMENTE,CA 92673 VICINITY MAP LOCATION MAP SAC/ZONING/PERMITTING: SENIOR TECHNICAL PROJECT MANAGER: M SQUARED WIRELESS AT&T SHEET TITLE 1387 CALLE AVANZADO 1452 EDINGER AVE. SAN CLEMENTE,CA 92673 TUSTIN,CA 92618 DIRECTIONS FROM AT&T OFFICE: 7. TURN LEFT ONTO AVACADO AVE D RAW I N G INDEX RF ENGINEER: CONTACT:TED SUEKAWA DIRECTION ARE TAKEN FROM 8. TURN RIGHT ONTO CIVIC CENTER DR TITLE SHEET AT&T EMAIL:TS4994@ATT.COM 1452 EDINGER AVE. 1452 EDINGER AVE. TUSTIN,CA 92780 DESTINATION WILL BE ON THE RIGHT. 1. TURN LEFT ONTO EDINGER AVE TUSTIN,CA 92618 190[CS]NEWPORT CENTER DRIVE(SLC5824),NEWPORT BEACH,CA 92660 CONTACT:KARLO DAVINAGRACIA 2. TURN LEFT ONTO STATE ROUTE 55 S SUBCONTRACTOR SHALL VERIFY ALL PLANS&EXISTING DIMENSIONS 8 CONDITIONS ON EMAIL:KD270J@ATT.COM 3. MERGE ONTO STATE ROUTE 55 S THE JOB SITE&SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY SHEET NUMBER 4. TAKE EXIT 5A TOWARD STATE ROUTE 73 S DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. 5, TAKE EXIT 14A TO MERGE ONTO MACARTHUR BLVD 6. TURN RIGHT ONTO SAN MIGUEL DR T 1 PROJECT TEAM DRIVING DIRECTIONS DO NOT SCALE DRAWINGS 1. THE FACILITY IS AN UNOCCUPIED DIGITAL TELECOMMUNICATION FACILITY. Q NEW ANTENNA GROUT OR PLASTER T T TELCO (FIBER) RUN 5/8" X 10'-0" ,CU. GND ROD IN 2. PLANS ARE NOT TO BE SCALED AND ARE INTENDED TO BE A DIAGRAMMATIC EXISTING ANTENNA O (E) BRICK TEST WELL 30' MIN. BELOW GRADE. OUTLINE ONLY, UNLESS NOTED OTHERWISE. THE WORK SHALL INCLUDE FURNISHING UNDERGROUND TELCO RUN MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO COMPLETE ® GROUND ROD (E) MASONRY T T e CHEMICAL GROUND ROD ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS.(XIT GROUND ROD) ���� ---E-----E--- UNDERGROUND ELECTRICAL RUN 3. PRIOR TO THE SUBMISSION OF BIDS, THE CONTRACTORS SHALL VISIT THE JOB Tr GROUND BUS BAR CONCRETE SITE AND BE RESPONSIBLE FOR ALL CONTRACT DOCUMENTS, FIELD CONDITIONS CADWELD CONNECTION AND DIMENSIONS, AND CONFIRMING THAT THE WORK MAY BE ACCOMPLISHED AS • MECHANICAL GRIND. CONN. EARTH ---E/T-----E/T--- UNDERGROUND ELECTRICAL/TELCO RUN SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES ARE TO • BE BROUGHT TO THE ATTENTION OF THE IMPLEMENTATION ENGINEER AND GRAVEL MECHANICAL CONNECTION ENGINEER PRIOR TO PROCEEDING WITH THE WORK. ■ CADWELD � c c GROUNDING CONDUCTOR 4. THE CONTRACTOR SHALL OBTAIN, IN WRITING, AUTHORIZATION TO PROCEED ❑ ® PLYWOOD .4 HALO GROUND CONNECTION BEFORE STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED OR IDENTIFIED BY GROUND ACCESS WELL THE CONTRACT DOCUMENTS. SAND FUSE, SIZE AND TYPE AS INDICATED. fL CIRCUIT BREAKER 5. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN - �E ELECTRIC BOX ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY O WOOD CONT. u SAFETY SWITCH, 2P-24OV-60A W/60A FUSES, NEMA 3R INDICATED OTHERWISE OR WHERE LOCAL CODES OR REGULATIONS TAKE ENCLOSURE, SQ D CATALOG NO. H222NRB PRECEDENCE. TELEPHONE BOX � WOOD BLOCKING Q UTILITY METER BASE ERIC550N MANUAL TRANSFER SWITCH, 2P-240V-200A, NO FUSE, 6. ALL WORK PERFORMED AND MATERIALS INSTALLED SHALL BE IN STRICT LIGHT POLE STEEL O1 NEMA 3R ENCLOSURE 0 ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES. 330 COMMERCE,STE.200 r� TRANSFORMER CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, CENTERLINE LIGHTING FIXTURE, FLUORESCENT, 10.94" x 4'-0", 2/40W, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC IRVINE,CA 92602 SURFACE MOUNTING TYPE, HUBBELL LIGHTING CATALOG AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. MECHANICAL AND ® END. MONUMENT ® SURFAC 2T ELECTRICAL SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE PROPERTY/LEASE LINE IT] STEPDOWN TRANSFORMER MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND STATE LIGHTING FIXTURE, FLUORESCENT, 10.94" x 8'-0", 2/95W, JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. SPOT ELEVATION MATCH LINE SURFACE MOUNTING TYPE, HUBBELL LIGHTING CATALOG #TWSM232T (D RECEPTACLE, 2P-3W-125V-15A, DUPLEX, 7, THE GENERAL CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK, USING THE LIGHTING FIXTURE, HIGH PRESSURE SODIUM, 1/70W, WALL GROUND TYPE, HUBBEL CATALOG #5362 BEST SKILLS AND ATTENTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE SET POINT FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND WORK POINT MOUNTING TYPE, HUBBELL LIGHTING CATALOG #NRG-307 PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE (� ■� r7 OR 1/50W, HUBBELL LIGHTING CATALOG #NRG-121 S TOGGLE SWITCH, 1P-125V-15A, M 5�IJ A R `•� CONTRACT INCLUDING CONTACT AND COORDINATION WITH THE IMPLEMENTATION Al REVISION GROUND CONDUCTOR I� EXIT SIGN, THERMOPLASTIC LED, SINGLE FACE, UNIVERSAL HUBBELL CATALOG #HBL 1201CN ENGINEER AND WITH THE LANDLORD'S AUTHORIZED REPRESENTATIVE. WIRELESS F1�7 MOUNTING, W/BATTERY PACK, HUBBELL LIGHTING CATALOG #PRB SWP TOGGLE SWITCH, 1 P-120V-15A, "WP" 8. SEAL PENETRATIONS THROUGH FIRE RATED AREAS WITH U.L. LISTED AND FIRE 1 3 8 7 C A L L E A V A N Z A D O O GRID REFERENCE A COAXIAL CABLE COMBINATION, EXIT SIGN & EMERGENCY LIGHTING, CODE APPROVED MATERIALS. SAN CLEMENTE CA 92873(949)391-8824 ou OVERHEAD SERVICE EXIT HUBBELL LIGHTING CATALOG #PRC IONIZATION SMOKE DETECTOR W/ALARM 9. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN DETAIL REFERENCE CONDUCTORS O HORN &AUXILIARY CONTACT, 120 VAC, 2-A OR 2-A10BC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF THE EMERGENCY LIGHTING, 2/50W, HUBBELL LIGHTING CATALOG GENTEX PART NO. 710OF PROJECT AREA DURING CONSTRUCTION. X CHAIN LINK FENCING #HE6-50-2-R91 POLE 10. DETAILS ARE INTENDED TO SHOW END RESULT OF DESIGN. MINOR MODIFICATIONS X ELEVATION REFERENCE —01Ri41-0H1�°XP— OVERHEAD TELEPHONE/OVERHEAD POWER ^ LIGHTING FIXTURE, INCANDESCENT, 1/100W, WALL MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, AND SUCH I�l MOUNTING TYPE, HUBBELL LIGHTING CATALOG MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK. #BRH-100-06-1 (N) POLE MOUNTED XFMER DRAWN BY: EG — OVERHEAD TELEPHONE LINE 11. REPRESENTATIONS OF TRUE NORTH, OTHER THAN THOSE FOUND ON THE PLOT OF X on. ux. SURVEY DRAWING (SHEET LS1 OR SHEET C-1), SHALL NOT BE USED TO SECTION REFERENCE LIGHTING FIXTURE, HALOGEN, QUARTZ, 1/30OW, HUBBELL 0 (E) POLE MOUNTED XFMR IDENTIFY OR ESTABLISH THE BEARING OF TRUE NORTH AT THE SITE. THE CHECKED BY: VIM—oxP oxr— OVERHEAD POWER LINE LIGHTING CATALOG #QL-505 CONTRACTOR SHALL RELY SOLELY ON THE PLOT OF SURVEY DRAWING AND ANY SURVEYOR'S MARKINGS AT THE SITE FOR THE ESTABLISHMENT OF TRUE NORTH, E ELECTRICAL RUN (N) PAD MOUNTED XFMER AND SHALL NOTIFY THE ENGINEER PRIOR TO PROCEEDING WITH THE WORK IF LYY LIGHTING FIXTURE, 1/175W. METAL HALIDE, HUBBELL CAT ANY DISCREPANCY IS FOUND BETWEEN THE VARIOUS ELEMENTS OF THE WORKING ELECTRICAL/TELCO RUN �( #MIC-0175H-336 DRAWINGS AND THE TRUE NORTH ORIENTATION AS DEPICTED ON THE CIVIL �Q (E) PAD MOUNTED XFMER SURVEY. THE CONTRACTOR SHALL ASSUME SOLE LIABILITY FOR ANY FAILURE TO 0 5/8" X 10'-0" ,CU. GND ROD 30" MIN. BELOW GRADE. NOTIFY THE ENGINEER. 12. THE CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING ABBREVIATIONS IMPROVEMENTS, PAVING, CURBS, VEGETATION, GALVANIZED SURFACES, ETC., AND UPON COMPLETION OF WORK REPAIR ANY DAMAGE THAT OCCURRED DURING CONSTRUCTION TO THE SATISFACTION OF AT&T. A AMPERE EMT. ELECTRICAL METALLIC TUBING MTD MOUNTED T.O.F. TOP OF FOUNDATION 13. KEEP GENERAL AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DIRT, DEBRIS, A.B. ANCHOR BOLT E.N. EDGE NAIL MI MOUNTING T.O.P. TOP OF PLATE (PARAPET) RUBBISH AND REMOVE EQUIPMENT NOT SPECIFIED AS REMAINING ON THE ABV. ABOVE ENCL. ENCLOSURE MTL METAL T.O.S. TOP OF STEEL PROPERTY. LEAVE PREMISES IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, AC ALTERNATE CURRENT/AIR CONDITIONER ENG. ENGINEER MTS. MANUAL TRANSFER SWITCH T.O.W. TOP OF WALL DUST OR SMUDGES OF ANY NATURE. A 02/08/201'9 90%CONSTRUCTION ACCA ANTENNA CABLE COVER ASSEMBLY EQ. EQUAL INNEUTRAL TYP. TYPICAL REV DATE DESCRIPTION ADD'L ADDITIONAL EXST.(E) EXISTING (N) NEW U.G. UNDER GROUND 14. PENETRATIONS OF ROOF MEMBRANES SHALL BE PATCHED/FLASHED AND MADE A.F.F. ABOVE FINISHED FLOOR EXP. EXPANSION NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOC. U.L. UNDERWRITERS LABORATORY INC. WATERTIGHT USING LIKE MATERIALS IN ACCORDANCE WITH NRCA ROOFING A.F.G. ABOVE FINISHED GRADE EXT. EXTERIOR NO.(#) NUMBER UMTS UNIVERSAL MOBIL TECH. SYS. (3G MOBILE TECH.) STANDARDS AND DETAILS. CONTRACTOR SHALL OBTAIN DETAILING CLARIFICATION AC AMPERE INTERRUPTING CAPACITY FAB. FABRICATION(OR) N.T.S. NOT TO SCALE U.N.O. UNLESS NOTED OTHERWISE FOR SITE-SPECIFIC CONDITIONS FROM ENGINEER, IF NECESSARY, BEFORE ALUM. ALUMINUM FAC. FACTOR OBIF OPTICAL BASEBAND INTERFACE V VOLT PROCEEDING. ALT. ALTERNATE F/A FIRE ALARM OH OVERHEAD VAC VOLT ALTERNATING CURRENT ANT. ANTENNA F.F. FINISH FLOOR O.C. ON CENTER V.I.F. VERIFY IN FIELD �pFESSjpV APPROX. APPROXIMATELY)) F.G. FINISH GRADE OPNG. OPENING W WATT OR WIRE 15. BEFORE ORDERING AND/OR BEFORE FABRICATING/CONSTRUCTING/INSTALLING ANY �O� W�'� ARCH. ARCHITECTURAL) FIN. FINISH(ED) P POLE WD WIDE(WIDTH) ITEMS, VERIFY THE TYPES AND QUANTITIES. AT. AMPERE TRIP FLR. FLOOR P/C PRECAST CONCRETE W/ WITH R' p1Y AWG. AMERICAN WIRE GAUGE FLUOR FLUORESCENT VC PERSONAL COMMUNICATION SERVICES W/0 WITHOUT 16. CONTRACTOR SHALL PROVIDE SITE FOREMAN WITH A CELLULAR PHONE AND BATT. BATTERY FDN. FOUNDATION PH PHASE W WOOD PAGER, AND KEEP SAME ON SITE WHENEVER PERSONNEL ARE ON SITE. G7 V is BD. BOARD F.O.C. FACE OF CONCRETE PLY. PLYWOOD W.P. WEATHERPROOF m BLDG. BUILDING F.O.M. FACE OF MASONRY PNLBD PANELBOARD WT. WEIGHT V BLK. BLOCK F.O.S. FACE OF STUD PPC POWER PROTECTION CABINET XFER TRANSFER 17. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS ON THE SITE Lu I� BLKG. BLOCKING F.O.W. FACE OF WALL PRO PRIMARY RADIO CABINET XFMR TRANSFORMER AND NOTIFY THE PROJECT MANAGER OF ANY DISCREPANCIES BEFORE STARTING BM. BEAM F.S. FINISH SURFACE PRI PRIMARY XLPE CROSS-LINK POLYETHYLENE ANY WORK. B.N. BOUNDARY NAILING FT.(') FOOT (FEET) P.S.F. POUNDS PER SQUARE FOOT Q CENTERLINE BR. BRANCH FTG. FOOTING P.S.I. POUNDS PER SQUARE INCH P PLATE, PROPERTY LINE 18. CONTRACTOR TO PROVIDE COMPLETE SET OF AS BUILT DRAWINGS WITHIN 10 BRKR. BREAKER FU FUSE P.T. PRESSURE TREATED WORKING DAYS OF PROJECT COMPLETION. BTCW. BARE TINNED COPPER WIRE G GROUND PWR. POWER (CABINET) l C10- STE. BASE TRANSMISSION SYSTEM GR GROWTH (CABINET) QTY. QUANTITY ��r B.O.F. BOTTOM OF FOOTING GA. GAUGE RAE(R) RADIUS 19. CONTRACTOR IS TO EXCAVATE 6" BELOW EXISTING GRADE AND SPRAY WITH WEED OF CA4�F B/U BACK-UP CABINET GEN. GENERATOR RBS RADIO BASE STATION CONTROL. REPLACE WITH CLASS II AGGREGATE BASE AND CRUSHED WASHED C CONDUIT GI. GALVANIZE(D) (BASE STATION 3G NETWORKS) ROCK. AS SPECIFIED ON SITE PLAN. CAB. CABINET G.F.C. I. GROUND FAULT CIRCUIT INTERRUPTER RCPT. RECEPTACLE CANT. CANTILEVERED) GLB. (GLU-LAM) GLUE LAMINATED BEAM REF. REFERENCE 20. CONTRACTOR SHALL PROVIDE TOILET FACILITY DURING ALL PHASES OF CB. CIRCUIT BIR AKER GND GROUND REINF. REINFORCEMENT(ING) CONSTRUCTION. IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY CDMA CODE—DIVISION MULTIPLE ACCESS (2G & 3G) GPS GLOBAL POSITIONING SYSTEM REQ'D. REQUIRED ARE ACTING UNDER THE DIRECTION OF A LICENSED CDUK CONSOLIDATION DISTRIBUTION UNIT KIT GRND. GROUND RGS. RIGID GALVANIZED STEEL 21. PRIOR TO THE COMMENCEMENT OF CONSTRUCTION OR THE FABRICATION OF PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. C.I.P. CAST IN PLACE GSM GLOBAL SYSTEM MOBILE (2G+ MOBILE TECH.) RRU REMOTE RADIO UNIT MATERIALS TO BE INSTALLED AT THE SITE, THE CONTRACTOR SHALL FIELD VERIFY CLG. CKT. CEILING NOR HEADER CIRCUIT HDBC HARD DRAWN COPPER WIRE (RADIO TRANSCEIVER) ALL DIMENSIONS INCLUDING AS-BUILT DIMENSIONS OF EXISTING STRUCTURES OR RX-AIT RECEIVER AIR INTERFACE TRAY. CLR. CLEAR HGR. HANGER SAT SAFETY STRUCTURAL ELEMENTS HAVING A BEARING ON THE SCOPE OF THE WORK TO BE CMU CONCRETE MASONRY UNIT (JAMB BLOCKS) UPS HIGH PRESSURE SODIUM SCH. SCHEDULE PERFORMED. IF ANY DISCREPANCY IS FOUND BETWEEN THE VARIOUS ELEMENTS COL. COLUMN HT. HEIGHT SDBC SOFT DRAWN BARE COPPER OF THE WORKING DRAWINGS AND THE DIMENSIONS OR CONDITIONS FOUND TO BE CONC. CONCRETE ICGB. ISOLATED COPPER GROUND BUS SEC SECONDARY EXISTING IN THE FIELD, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND SITE ID:CSTAM 02A CONN. CONNECTION(OR) IN.(") INCH(ES) SHT. SHEET OBTAIN DESIGN RESOLUTION PRIOR TO PROCEEDING WITH THE PORTION(S) OF THE 190 CS NEWPORT CENTER CONST. CONSTRUCTION INT. INTERIOR SIM. SIMILAR I CONT. CONTINUOUS LB.(#) POUND(S) S.N. SOLID NEUTRAL WORK AFFECTED. THE CONTRACTOR SHALL ASSUME SOLE LIABILITY FOR ANY d PENNY (NAILS) L.B. LAG BOLTS SPEC. SPECIFICATIONS) FAILURE TO SO NOTIFY THE ENGINEER AND OBTAIN RESOLUTION BEFORE DRIVE(SLC5824) DBL. DOUBLE L.F. LINEAR FEET (FOOT) SQ. SQUARE PROCEEDING. NEWPORT BEACH,CA,92660 DC DIRECT CURRENT LG. LENGTH S.S. STAINLESS STEEL DEM. DEMAND L. LONG(ITUDINAL) STD. STANDARD DEPT. DEPARTMENT LIPS LOW PRESSURE SODIUM STL. STEEL DF. DOUGLAS FIR LTE LONG TERM EVOLUTION (4G MOBILE TECH.) STRUC. STRUCTURAL DIA. DIAMETER MAS. MASONRY SURF SURFACE DIAG. DIAGONAL MAX. MAXIMUM SW SWITCH SHEET TITLE DIM. DIMENSION M.B. MACHINE BOLT TEL. TELEPHONE DWG. DRAWING S) MECH. MECHANICAL TEMP. TEMPORARY OWL. DOWEL(S MFR. MANUFACTURER THK. THICK(NESS) GENERAL MOTES EA. EACH MIN. MINIMUM TMAS TOWER MOUNTED AMPLIFIER EGR. EMERGENCY GENERATOR RECEPTACLE MISC. MISCELLANEOUS (DC SUPPLY VOLTAGE) EL. ELEVATION MLO MAIN LUGS ONLY T.N. TOE NAIL ELEC. ELECTRICAL T.O.A. TOP OF ANTENNA ELEV. ELEVATOR T.O.C. TOP OF CURB SHEET NUMBER GN-1 ABBREVIATIONS 3 GENERAL NOTES 4 NOTE: 1. IF DIMENSIONS SHOWN ON PLAN DO NOT SCALE CORRECTLY,CHECK FOR REDUCTION 0 0 LL GI LL 3 OR ENLARGEMENT FROM ORIGINAL PLANS. 2. UTILITY DESIGN&RUNS ARE PRELIMINARY.PENDING FINAL DESIGN FROM UTILITY I PROVIDERS. I I 3. CONTRACTORS TO VERIFY SUB STRUCTURE LOCATIONS PRIOR TO ANY EXCAVATION. i 4. ALL CONDUCTORS/WIRES&CONDUIT,SHALL BE INSTALLED IN A NEAT 7 TIDY FASHION. ALL EXCESS WIRE SLACK IS TO BE REMOVED&HIDDEN AS MUCH AS POSSIBLE. at&t I 5. ALL NEWLY INSTALLED EQUIPMENT SHALL BE PAINTED TO MATCH EXISTING POLE,& BUILDING I I OR SURROUNDINGS UNLESS PROHIBITED PER MANUFACTURER. i (TYP.)6. NEW FIBER CONDUIT TO BE STUBBED OUT OF NEW POLE FOOTING BY APPROX.2'-0". 130'-0" I ' 49'-0" 49'-0" I I I I I ' Z E RI C550N I m \ 330 COMMERCE,STE.200 IRVINE,CA 92602 I \\ (N)U/G FIBER RUN FROM(N)FIBER HANDHOLE TO I m i (N)CONCRETE STREETLIGHT(BY AT&T);SEE NOTE 6 4 I � ,. NEWAT&TPROJECTLOCATION. �2 ``\` M SQUAR(•J m / SEE ENLARGED SITE PLAN (N)FIBER SEPARATE (BY OTHERS `� (N)CITY OF NEWPORT BEACH CONCRETE UNDER SEPARATE PERMIT) WIRELESS STREETLIGHT(5824)W/(N)EQUIPMENT(BY AT&T) ❑ .Ir---�---�-- ----�� (E)HANDHOLE . ' TO(NGCOWRE TESTR M(N)W(BYANDHOLE - 7997 CNELE A39NZADO (E)CITY OF NEWPORT BEACH SAN CLEMENTE CA 92673(949)391$824 REMOVED&REPLACEDCONCRETE F(BYAT&T)824) O BE "q D-19 I (N)WTR HANDHOLE(BY AT&T) I 1.2 \ A-2 CT DRAWN BY: EG CHECKED BY: MM (E)STORM DRAIN I ROw C/F t90'-0"TO E _ OF NEWPORT CENTER DR CIVIC CENTER DR CIVIC CENTER DR i A 02/OB/2019 90%CONSTRUCTION N —� REV DATE DESCRIPTION LD I � � ciF � �pF E551fl�C ----Row y Oyu" •i O�Y� (E)TRAFFIC LIGHT(TYP.) I CIF r Crvi�- I I I )' OF CA4�F I I I (E)TREE(TYP.) IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY I (E)TRAFFIC LIGHT(TYP.) ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. 1 (E)SIDEWALK(TYP.) (E)PARKWAY(TYP.) I I / (E)TREE(TYP.) I � I SITE ID:CSTAM 02A / (E)SIDEWALK(TYP.) 190[CS]NEWPORT CENTER a I I / /'' (E)PARKWAY(TYP.) DRIVE(SLC5824) I BUILDING NEWPORT BEACH,CA,92660 (TYP.) / I I I I / SHEET TITLE SITE PLAN t I 1 I N I N � 1 I -� I U �w EA, 0 'OW E� SHEET NUMBER Jo s � Jo S � A-1 SITE PLAN 11"x36" SCALE: 1" = 20'-0" 20' 40 1 ENLARGED SITE PLAN 24"x36" SCALE: 1/8" = 1'- " 4' S' 6' A "x17" SCALE: 1" = 40'-0" 11"x17" SCALE: 1/16"= 1'-0O" L NOTE: ALL NEW EQUIPMENT SHALL BE PAINTED TO MATCH NEW CONCRETE LIGHT POLE (N)14"DIA.EQUIPMENT SHROUD W/(1) ; (N)ANTENNA,(2)(N)AT&T 2203 RADIO, 1-5 ���� T/OF(N)ANTENNA/EQUIPMENT SHROUD (1)(N)2205 RADIO&(1)FUTURE 2205 p_i M 39'-0"A.G.L. RADIO&(1)(N)RAYCAP DISCONNECT �. }�C/L OF(N)ANTENNA SWITCH WITHIN SHROUD -- 38'-0"A.G.L. e/OF(N)ANTENNA 37'-0"A.G.L. B/OF N EQUIPMENT SHROUD ERICSSON 3z'-irA.G.L. 330 COMMERCE,STE.200 T/OF N POLE IRVINE,CA 92602 C/L OF(E)LUMINAIRE 32'-11'A.G.L. 31'-0"A.G.L. C/L OF N LUMINAIRE M SQUTAWRER(•j 1387 CALLE AVANZADO SAN CLEMENTE CA 92673(949)391-6824 DRAWN BY: EG CHECKED BY: MM A 02/08/2019 90%CONSTRUCTION REV I DATE DESCRIPTION ��pF E55rfl�� y���P� Lu 50 7 C (E)CITY OF NEWPORT BEACH CONCRETE STREETLIGHT �J' C10— (5824)TO BE REMOVED&REPLACED(BY AT&T) 7-9 (N)WTR HANDHOLE D-1 (BEYOND) (BY AT&T) E POLE FOUNDATION TO 8E N CITY OF NEWPORT BEACH IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY REMOVED&REPLACED AT&T) (N)FIBER BOX CONCRETE STREETLIGHT(ID S-1 ARE ACTING UNDER THE DIRECTION OF A LICENSED D-1 (BY OTHERS) TED)(BY AT&T) PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. (N)POLE FOUNDATION(BY AT&T) E GROUND LEVEL E GROUND LEVEL 0'-0"A.G.L. 0'-0"A.G.L. SITE ID:CSTAM 02A 190[CS]NEWPORT CENTER DRIVE(SLC5824) NEWPORT BEACH,CA,92660 SHEET TITLE ELEVATIONS SHEET NUMBER EXISTING SOUTHWEST ELEVATION 114"x17" SCALE: 3/116"—='1'OC" 1 2 NEW SOUTHWEST ELEVATION 24"x36" S°ALE: 3/ _ ''—D" Z' A-2 11"x17" SCALE: 3/16" = 1'—O" NOTE: ALL NEW EQUIPMENT SHALL BE PAINTED TO MATCH NEW CONCRETE LIGHT POLE (N)14"DIA.EQUIPMENT SHROUD W/(1) ; (N)ANTENNA,(2)(N)AT&T 2203 RADIO, 1-5 ���� T/OF(N)ANTENNA/EQUIPMENT SHROUD (1)(N)2205 RADIO&(1)FUTURE 2205 p_i 39' A.G.L. RADIO&(1)(N)RAYCAP DISCONNECT �. C/L OF(N)ANTENNA SWITCH WITHIN SHROUD -- 38'-0'A.G.L. B/OF N ANTENNA 37'-0"A.G.L. C/L OF(E)LUMINAIRE C/L OF(N)LUMINAIRE 35'-0"A.G.L. A.G.L. - B/OF N EQUIPMENTSHROUD ERICSSON 32•-11'A C+. L 330 COMMERCE,STE.200 T/OF N POLE IRVINE,CA 92602 32'-11"A.G.L. w II II II II II I ' M SQUAR(•j II WIRELESS 1387 CALLE AVANZADO li SAN CLEMENTE CA 92673(949)391-6824 II II I I I I I I I I I I I I I I I I I I I I DRAWN BY: EG I I I I � I CHECKED BY: MM I I I I I I I I I I I I I I li I I I I I I i I I I I I I I I I II I A 02/08/2019 90%CONSTRUCTION I I REV DATE DESCRIPTION I I I I I I I I I I I I I I I I ��pF E55lfl�A I Op.1�-�Wy��°2 2 I 'u 5a 7 " I I I I (E)CITY OF NEWPORT BEACH CONCRETE � C+0- C�� STREETLIGHT(5824)TO BE REMOVED&REPLACED �r (BY AT&T) COCITYOFN BEACH OF C�4�F I I CONCRETE STREETLIGHT(ID S-1 I TBD)(BY AT&T) i (N)POLE FOUNDATION(BY AT&T) (E)POLE FOUNDATION TO BE IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY 7_9 ARE ACTING UNDER THE DIRECTION OF A LICENSED REMOVED&REPLACED(BY AT&T) (N)WTR HANDHOLE(BY AT&T) D-1 PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. 3 0 �(N)FIBER BOX(BY OTHERS) OD LEVEL OD LEVEL SITE ID:CSTAM 02A 190[CSI NEWPORT CENTER DRIVE(SLC5824) NEWPORT BEACH,CA,92660 SHEET TITLE ELEVATIONS SHEET NUMBER EXISTING SOUTHEAST ELEVATION 114"x17" SCALE: 3/116"-='1'OC" 1 2 NEW SOUTHEAST ELEVATION 24"x36" S°ALE: 3/ _ ''-D" Z' A-3 11"x 17" SCALE: 3/16" = 1'-O" at&t ERICSSON 330 COMMERCE,STE.200 IRVINE,CA 92602 M S0.UAR(•j h WIRELESS }� 1387 CALLE AVANZADO SAN CLEMENTE CA 92673(949)391-6824 DRAWN BY: EG CHECKED BY: MM �41 i 1�1 ~T1 F A 02/08/2019 90%CONSTRUCTION REV DATE DESCRIPTION I �t oC rn NEW POLE LOCATION IT IS ARE ACTIN UNDER THE IIG VTO HEV DIRECTION OF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT, SITE ID:CSTAM 02A 190[CSI NEWPORT CENTER DRIVE(SLC5824) blool NEWPORT BEACH,CA,92660 SHEET TITLE SITE IMAGE SHEET NUMBER NEW SITE LOCATION LOOKING NORTHWEST 24 x11"x36'1T17" SALE NTS A-4 SCALE: NTS COVER FEATURES: •STANDARD LOAD RATING:20,800 LBS.WHEEL LOAD ERICSSON MICRO RADIO 2205 GALTRONICS G02410416621 PSEUDO OMNI CANISTER ANTENNA ON 10"x20"PLATE MECHANICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS DIMENSIONS(VWD.HI: 7.8Tk4-7.87',INCLUDING MOUNTING DIMENSIONS(HxD): 24.9 x 10 INCHES •2 BOLT DOWN LOCATIONS BRACKET AND ESTHETIC FRONT COVER •STAINLESS STEEL BOX INSERTS VOLUME AND WEIGHT: 4 LITRES AND<4 kg(8.82lb,) (843 x 255 mm) MOUNTING: WALL AND POLE MOUNT NO.OF EXCL CONNECTORS MOUNTING BRACKETS: 10X 4.-10D ���� •POLYMER CONCRETE CONSTRUCTION NO.OF CONNECTORS 10X6.3-tODINFEMALE •NON-SKID SURFACE STANDARD LIFT PINS(2 PL) INTERFNA PORTCIFICATIQNS: _ ANTENNA PORTS: 2x4.}10(F) CONNECTOR TYPE S 4%4.}10 DIN FEMALE •20K TO BE EMBOSSED COVER Y ___ �' 7.87 7.57" 4.84" CPRI: 2 x 2.515110 Gbps(EXCHANGEABLE SEP 6 FREQUENCY BAND[MH,]: (1695-2360)MHz •APPROXIMATE WEIGHT=120 LBS. t __ MODULES) O 4X O 10DINFEMALE OPTICAL INDICATORS: 8 10 (S554.-00)MHz EXTERNAL ALARM: 2 2-3-1 DIN FEMALE _--- o FIELD GROUND: 1 O O . (5150-0) BOLT DOWNS(2 PL) MHz ELECTRICAL SPECIFICATIONS: MAX WIND SPEED: 150 mpb COVER FEATURES: 2"x8"NAMEPLATE POWER -0BVCDOR100-250VAC " O RADOMEM4TERIAL ASA -- � O O • POLYMER CONCRETE CONSTRUCTION RECESS(1 PL) 0 POWER OUTPUT: 97 WATTS MAX * 3 . SHIPPING DIMS(UMD): 30'X19'%19'(]62 48 x 83H m MAX HEATDISSIPATION: SO WATTS NON-SKID a O GROSS SHIPPING WEIGH: 2616s(12kg) • LIGHTWEIGHT (STANDARD) OO OO MINIMUM AC FUSE RATING: 6AMP O • STACKA. E FOOT IGHT PART NO.G0241 0-06 8 21-11(GRAY • APPROX.WEIGHT188LBS. z,z woo FRONT BACK SIDE B ® PART NO GQ2410-21-SI I BRQWN)PART NO.G02410-06621-B11( ) ERICSSON ��. 7.87" BOTTOM 330 COMMERCE,STE.200 IRVINE,CA 92602 3/8"x3"HEX BOLT (2 PL EA END) TOP FRONT x 9x (OR APPROVED EQUAL) 7`•d•�/ ��i� M SQUAR�•J WIRELESS HANDHOLE 24"x36" SCALE: NTS 7 ERICSSON - RADIO 2205 24"%36 SCALE NTS 4 GALTRONICS OMNI ANTENNA 24"x36" SCALE: NTS 799L CALLE AVANZADO 1 1"x 17" SCALE: NTS 1 1"x 17" SCALE: NTS 1 1"x 17" SCALE: NTS SAN CLEMENTE CA 92873(949)391-8824 ELECTROMATE RAYCAP RSCACS53&P-120.0 ERICSSON-MICRO RADIO 2203 - HINGED 3R ENCLOSURE MECHANICALSPECIFICATIONS ELECTRICAL MECHANICAL DIMENSIONS(WxD,H): T87-94"x].87°,INCLUDING MOUNTING DIMENSIONS: CONNECTION TERMINAL COMPRESSION LUG N-k14 AWG(13-2MMI BRACKETANDESTHETICFRONTCOVER SURGEPROTECTIONDEVICE(SPD)TYPE TO UL STRIKEBORB 30-A TERMINAL BLOCK p10- AWG(6-0.14MM2) VOLUME AND WEIGHT: 4 LITRES AND�4.5 kg I9921bs) A 12" NUMBE PROTE OF CIRCUITS PROTECTED ENVIRONMENTAL INGRESS MOUNTING: WALL AND POLE MOUNT SURGEPROTEOTIVE MPONEVICESEMBL VPE PER ILL 14494TH EDITION: PROTECTION IIP)RATING: NEMABX B 12" TYPE2CCTION COMPONENT ASSEMBLYOPERATIONTEMPERATURE: (°C)-00°CTO aWC DRAWN BY: EG SURGE PROTECTION DEVICE(SPD)CLASS TO IEC 61fid311:CLASS INTERFACE SPECIFICATIONS: STORAGE TEMPERATURE: (°C)-]0°CTO a80°C C 6" NOMINAL OPERATING VOLTAGE IUM:120V ENCLOSURETYPE _ 7.87" 7.B7" 3.94" ANTENNA PORTS: 2x4.3-10(F) No DISCHARGE CURRENT[IM PER ILL 14494TH EDITION:20 KA 8120 MS f—RATEDCPRI: 2 x 2.SI5I10 Gbpa(EXCHANGEABLE SFP MAX IM UM DISCHARGE CURRENT[IMAXI PER IEC 6164}1160 KA SWIMS ENCLOSURE(OUTDRDIMEN ION�NA��(L 9W H&N-X SAS'X f0.W' MODULES) CHECKED BY: MM MA%IMUM CONTINUOUS OPERATING VOLTAGE[UCI ICOV)150V [217"128.256 MM] OPTICAL INDICATORS: 6 VOLTAGE PROTECTION LEVEL[UP]PER IEC 6184}11:700V WEIGHT: 2.25 LBS[1.02KGI VOLTAGE PROTECTION RATING NPR):20 KA 8120 EXTERNAL ALARM: 2 SUPPRESS ION TECHNOLOGY:MOV FIELD GROUND: 1 PROTECTION MODES(DUAL MODE):LINE TO NEUTRAL,NEUTRAL TO GROUND ELECTRICAL SPECIFICATIONS: e,eas,,.m,z,ie�cez,,.zmz i�euzx,.mmirteuz"s. POWERSUPPLY: 48 VCD OR 100-250 VAC r r POWER OUTPUT: 97 WATTS MPX 1 D.28" ew�sox Q Q M HEAT DISSIPATION — MINIMUM AC FUSE RATING 6AMP 8.59" FRONT BACK SIDE Q tD 7.a7" A 02/OB/2019 90%CONSTRUCTION co - °J REV DATE DESCRIPTION � a O O o ® N NPT 1"GLAND CAN BE REPLACED BY TOP E C CONDUIT FITTING 0 /Q FRON7 SIDE BOTTOM M40 GLANDS CAN BE REPLACED BY 1 W �� 6.25" 1/4"NPT CONDUIT FITTINGS y oyP o� m SCE UN-METERED FUSED PANEL 111 x17" SCALE: NTS 8 RAYCAP DISCONNECT 11 x17 SALE NTS 5 ERICSSON - RADIO 2203 11 X36" SCALE: NTS 5a 7 11"x17 SCALE: NTS 2 SQUARED AVAILABLE FROM EXCEL SIGN AND DECAL: oo"oEALFAB CONCEALMENT POLE TOP ECCENTRIC 1 1 HINGED 3R ENCLOSURE MECHANICAL SPECIFICATIONS ��' CIVI C} H D221 NRB http://www.weneedsigns.com/home.php?cal+l135 AND CLICK ON AT&T DIMENSIONSIHxD): ]2'x011 VENTS �r QF C�4`T�O DIMENSIONS: PH:510-651-0445 MOUNTING: MOUNTS TO TOP OF POLE " [� A 7.75" N01-DC-16 1"X6"NOTICE DECAL VII B 9.63" "For 1 Foot Distance"VINYL DECAL WITH ADHEDSIVE BACKING 014 14'DIA.SHROUD 3.75" IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY C ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. GALTRONICS PE4801 SITE ID:CSTAM 02A NOTICE ,off• ANTENNA 72• 190[CS]NEWPORT CENTER 0 �01 DRIVE(SLC5824) RF energy emitted by this device may exceed the FCC's general 4' public exposure limits.Stay at least 1 foot away from the device. ' DUALERICSSON DUAL ERICSSON NEWPORT BEACH,CA,92660 O Call 800-638-2822 for help if you need access within>foot 2203 RADIO 22203 RADIO a RAVCAP DISCONNECT SHEET TITLE Place 3 NOTICE sticker at the bottom of the front of DETAILS the radome of each antenna. t„ ' l s PROPOSED SCE iROF03®SCE MARGIN AWRCNCONCAElE RDLE CONCRETE POLE pr OdHE�fl (BYOTHERS) - SHEET NUMBER 0 O ciONF RPJw110N VCM Ia Ov.rg�Aply 5: D_ EIPILA�60NEIilC NEW AT&T MOBILITY FUSED DISCONNECT 4"x17" SCALE: NTS 9 OMNI ANTENNA DISCLAIMER LABEL 24"X36 SCALE: NTS 6 EQUIPMENT SHROUD 24"x36" SCALE: NTS 3 11"0 7" SCALE: NTS 11"x17" SCALE: NTS 5" NOTES: 1. THIS INFORMATION MAY NOT CONTAIN ALL DETAILS REQUIRED FOR CONSTRUCTION. AT&T TOWERS APPROPRIATE MODIFICATION MAY BE REQUIRED TO ENSURE SUITABILITY OF THESE ���� DRAWINGS FOR THE SPECIFIC APPLICATION. In case of Emergency Contact 2. FOR FIBER CONDUIT, STUB OUT FROM FOUNDATION AWAY FROM STREET SIDE FOR E-mail:atttowers@att.com FUTURE FIBER HANDHOLE INSTALLATION. Phone:(877)231-5447 3. WHERE KNOWN HIGH SULFATE CONTENT EXISTS IN SOIL, USE TYPE V CEMENT. Please Reference Site ID Site ID cRAN_RLos_csraN_ooz FCC ID 0 POLE PER PLAN - OWNER / OPERATOR NOTE: HANDHOLE SITE ID LABEL TO BE AFFIXED AT OR NEAR THE POINT OF (4) 1"0 X 36" ANCHOR RODS PVC CONDUIT STUBBED UP ERICSSON POWER CONNECTION WITH TZeS241 LABELING TAPE OR ADJACENT TO HAND HOLE, EQUIVALENT BLACK ON WHITE LABELING TAPE OF AT LEAST WITH 9G' HOOK & a" PRGJ. NUMBER AND SIZE AS REQUIRED 18mm WIDTH WITH EXTRA—STRENGTH ADHESIVE. USE ANY (MIN. 55 KSI) NO GAP — SEAL WITH 330 COMMERCE,STE.200 COMPATIBLE P—TOUCH LABEL MAKER. TEXT SHOULD BE U NON—SHRINK LEVELING GROUT IRVINE,CA 92602 PRINTED IN ALL CAPS WITH A MINIMUM HEIGHT OF 1/2". FINISHED GRADE n IT - v EMERGENCY CONTACT SIGN ul � 5" m = - M SQUAR •j WIRELESS • CIRCUIT CONDUCTORS & 1387 CALLE AVANZADO CONDUIT TO NEXT POLE, TYP., SAN CLEMENTE CA 92673(949)391-6824 SEE NOTE 2 4 I I #3 HORIZ. TIES AT 12" O.C. INSULATED COPPER GND MIN 3,00E PSI TYPE 6 II CONCRETE, SEE CONDUCTOR ATTACHED TO INTERNAL LUG(S) & BONDED TO NOTE 3 POLE & EXISTING GROUND _ PLATE OR ROD. SIZE GND COND. DRAWN BY: EG Stay Fuck PER iNFPA 70 AND CCAUSD Radio-frequency energy CHECKED BY: MM may exceed exposure limits. 12 - #5 BARS VERT. (60 KSI) If questions,contact facility owner. 0 0 EXISTING GROUND PLATE ANTENNA SIGNAGE: ON WOOD POLES — SIGN ON ALUMINUM WITH SS SCREW TO THE POLE (4) O X ANCHOR RODS W/ H 90' HOOK (MIN 55 KSI) ON METAL POLES — ADHESIVE VINYL OR PLACARD STRAPPED WITH SS TIES #3 HORIZ. TIES ® 12" O.C. ON CONCRETE / COMPOSITE — PLACARD STRAPPED WITH POLE BASE PLATE LOCATION SS TIES7 A 02/08/2019 90%CONSTRUCTION SIGN PLACEMENT: o 12 — #5 BARS VERT. (60 KSI) AFFIX TO THE STRUCTURE 3-4' BELOW THE COMMERCIAL REV DATE DESCRIPTION RE ANTENNA(S) CONCREo PSI YPE II—V TE SIZE APPROX. 8" x 5" r-s ANTENNA SIGNAGE �01 P FE55r� eel o p.wy y oy o� m NOT USED 11.17;; SCALE: NTS 5 POLE MOUNTED SIGNS 11 x36 SCALE: NTS 3 NEW FOUNDATION 11%17" SCALE: NTS 11"x17" SCALE: NTS C10- QF r, 12"3 PATCH PAVING AS REQUIRED TO MATCH(E)SURFACE, WHERE OCCURS IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED UNDISTURBED NATIVE SOIL PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. 12" SAND OR ENGINEERED BACKFILL WITH 90%COMPACTION IN 8"LIFTS 2'-0"MIN. WARNING TAPE WITH TRACE SITE ID:CSTAM 02A WIRE AT V-0"BELOW GRADE 190[CS]NEWPORT CENTER (2)SACK SLURRY ENCASEMENT SLC5824 3'4'MIN. 12" WITH"RED"DYE DRIVE( ) (1)PVC SCH 40 CONDUIT FOR TELCO, NEWPORT BEACH,CA,92660 WHERE OCCURS,SIZE PER PLAN (2)SACK SLURRY ENCASEMENT,EXCEPT WHERE CONDUITS GO BELOW(N)BLOCK SHEET TITLE WALL PROVIDE CONCRETE ENCASEMENT (1)PVC SCH 40 CONDUIT FOR POWER, DETAILS WHERE OCCURS,SIZE PER PLAN 4"SAND BASE 4" SHEET NUMBER D-2 NOT USED 24"x36" SCALE: NTS 6 NOT USED 24"x36" SCALE: NTS 4 TRENCH DETAIL 24"x36" SCALE: NTS 11"x17" SCALE: NTS 11"x17" SCALE: NTS 11"x17" SCALE: NTS L FOR REFERENCE ONLY eplacement oT utv Owned street HE #lam �r'iT— pCil.yM�r r wtett�r -CnMx LJ V ru F!H - s+it-ems �'!+•.y_II�L3 ERICSSON 330 COMMERCE,STE.200 IRVINE,CA 92602 M SQ UAR1fiE•� WIRELESS� 14-L34kWl' W345 W=W-1 JI 1387 CALLE AVANZADO SAN CLEMENTE CA 92673(949)391-6824 �tlbS T71"Ca'1 A.k�1 r?t;s:•�"W'•� . - frf DRAWN BY: EG CHECKED BY: MM !7L(N ALK, A 02/08/2019 1 90%CONSTRUCTION REV DATE DESCRIPTION 1]lJJI_ Ky,.}k IC11Y Ckr IlMk)L 1lAL]rO OEaOhFadL1 ', I �pFE55rfl� Lu t,�C r74td:t1 :ar c3ttiexsl . 6. tI'p�r CIV14 QF Cp4�F 3� IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY I'7lUKi ARE ACTING UNDER THE DIRECTION OF A LICENSED WOW PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. � ��[ti�t•iytsl �I SITE ID:CSTAM 02A 190[CSI NEWPORT CENTER DRIVE(SLC5824) IW.MIX � 11_2-IVrM IMVIIt NEWPORT BEACH,CA,92660 EAR i1 N i!1i SHEET TITLE POLE DETAILS rx..,w tuarra=■.r.+sr=-� araresr r,+� 1 al QW272 i r SHEET NUMBER &T - Proprietary and confidential S-1 NOTE: EXOTHERMIC WELD CONNECTIONS 0 NOTE: ALL GROUND CONDUCTORS TO BE #6 UTILITY DESIGN AND RUNS ARE PRELIMINARY. PENDING THHN/THWN GREEN STRANDED COPPER MECHANICAL TYPE CONNECTIONS 0 FINAL DESIGN FROM UTILITY PROVIDERS UNLESS OTHERWISE NOTED OR REQUIRED BY EQUIPMENT MANUFACTURER. GROUNDING BAR (1) NEW 2205 RADIO & at&t • ACaR °"1 NEW ANTENNA D-1 • AC SOURCE (1) FUTURE RADIO • RRH-1 AND RRH-2 ARE SAME BAND, 2 EITHER B2 OR B66A °"1 (2) NEW 2203 RADIO AWS/PCS/WCS 5GHz RRH-3: (LAA), 2T2R MECHANICAL • USE OF DOUBLE MOUNTING BRACKETS a a a a a a CPRI CASCADING RRH-1/RRH-2 CONNECTION, TYP. + + + (1) NEW 2205 RADIO & / / D-1 (1) FUTURE RADIO - D1 (2) NEW 2203 RADIO - NEW #18 AWG ERICSSON THHN/THWN STRANDED 330 COMMERCE,STE.200 DOUBLE DOUBLE IRVINE,CA 92602 MOUNTING MOUNTING THWN GREEN-,, THHN BRACKET RRH-1 RRH-3 BRACKET NEW # / 2203 B2 OR B66A 2205 B46 STRANDED GROUND FROM OPR/QC OPR QC EQUIPMENT TO GROUND BUS PSU PSU . NEW GROUND D1 NEW RAYCAP DISCONNECT WITH M SQUAR(•J EPEE BUS BAR RRH-2 INTEGRATED SURGE PROTECTION t WIRELE S SB2 OR B66A OPR/QC NEW DISCONNECT O O 1387 CALLE AVANZADO WITH INTERGRATED P SAN CLEMENTE CA 92873(949)3918824 SURGE PROTECTION FIBER AC CABLE AC CABLE 9 NEW AT&T D-1 DISCONNECT Ac cABLE 9 NEW AT&T D1 DRAWN BY: EG DISCONNECT FIBER CHECKED BY: MIA B NEW SCE D1 UN—METERED AC CUT-OFF SWITCH FUSED PANEL � NEW SCE FIBER NEW #6 THHN/THWN UN—METERED DEMARCATION GREEN COPPERINNDED FUSED PANEL BOX/SPLICER Ac souRCE COATED MAIN GROUND CONDUCTOR/RISER EXOTHERMIC WELD NEW 1" SCH-80 PVC CONDUIT; A 02/08/2o1s 90%CONSTRUCTION DARK FIBERS CONNECTION TO NEW #12 AWG THHN/THWN STRANDED REV DATE DESCRIPTION TO/FROM HUB GROUND ROD NEW 5/8"0 x 8'-0" -_ NEW 120V POWER SERVICE OFE55rfl COPPER—CLAD STEEL Wf{ GROUND ROD _�— �kr p1] �Rpy EXISTING POWER SUPPLY ----- y Oy O� PICO PLUMBING DIAGRAM 11.17;; SCALE: NTS 5 GROUNDING SCHEMATIC 11 x36.. SCALE: NTS 3 SINGLE LINE DIAGRAM 11%17" SCALE: NITS 1 5p 7 11"x17" SCALE: NTS C10- QF CA4�F 0 STRIKESORB 120V PROTECTION IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY DISCONNECT SWITCH ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. U i 5 SITE ID:CSTAM 02A ,Ih CONNECTION FOR POWER IN 190[CS]NEWPORT CENTER U C- DRIVE(SLC5824) JUMPER GROUND NEWPORT BEACH,CA,92660 �. O CONNECTIONS DEAD-FRONT FOR LIVE 7 AMP CIRCUIT BREAKERS COMPONENTS SHEET TITLE ELECTRICAL DETAILS CHASSIS GROUND CONNECTION SHEET NUMBER E-1 NOT USED 24 x36 SALE NITS 6 NOT USED 11"x36" SCALE: NTS 4 BREAKER SCHEDULE 24"x36" SCALE: NITS 11'k17" SCALE: NTS 11"x17" SCALE: NTS 11"x17" SCALE: NITS L