Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAbout20190912_Staff Report
07/25/19
CITY OF NEWPORT BEACH
ZONING ADMINISTRATOR STAFF REPORT
September 12, 2019
Agenda Item No. 2
SUBJECT: Stupin Residence (PA2019-100)
Coastal Development Permit No. CD2019-033
SITE LOCATION: 3312-3318, 3322 and 3324 Via Lido
APPLICANT: Andrew and Julie Stupin
OWNER: Andrew Stupin (Via Lido Group II, LLC. and Palos V Investments, LLC.)
PLANNER: Liz Westmoreland, Assistant Planner
lwestmoreland@newportbeachca.gov, 949-644-3234
LAND USE AND ZONING
General Plan Land Use Plan Category: RM (Multiple-Unit Residential)
Zoning District : RM (Multi-Unit Residential)
Coastal Land Use Plan Category: RM-D (Multiple Unit Residential - 20.0 - 29.9
du\ac)
Coastal Zoning District: RM (Multi-Unit Residential)
PROJECT SUMMARY
The applicant requests a coastal development permit to allow the construction of a 7,868 -
square-foot, three-story single-family residence with four garage spaces consisting of 983
square feet. The project also includes the repair, reinforcement, and raising of an existing
bulkhead. No work is proposed bayward of the existing bulkhead. The design includes a
pool, spa, hardscape, walls, landscaping, and drainage facilities. The project complies
with all applicable development standards and no deviations are requested.
RECOMMENDATION
1) Conduct a public hearing;
2) Find this project exempt from the California Environmental Quality Act (CEQA)
pursuant to Section 15303 under Class 3 (New Construction of Conversion of Small
Structures), because it has no potential to have a significant effect on the environment;
and
3) Adopt Draft Zoning Administrator Resolution No. _ approving Coastal Development
Permit No. CD2019-033 (Attachment No. ZA 1).
1
Stupin Residence
Zoning Administrator, September 12, 2019
Page 2
Tmplt: 07/25/19
DISCUSSION
Land Use and Development Standards
The subject property is located in the RM Coastal Zoning District, which provides for
multi- and single-unit residential development and is consistent with the City’s
Coastal Land Use Plan, General Plan, and Zoning Code. A coastal development
permit (CDP) is required and the property is not eligible for a waiver for de minimis
development because the property is located in the Coastal Commission Appeal
Area.
On March 16, 2018, the Community Development director approved Staff Approval
No. SA2018-006 finding the demolition of a four-unit residential structure on the
project site to be in compliance with Zoning Code Chapter 20.34 and Local Coastal
Program Implementation Plan Chapter 21.34 (Conversion or Demolition of
Affordable Housing). The staff approval concluded that there will be no conversion of
residential to nonresidential uses, and none of the units are and/or were occupied by
low- and moderate income families or persons.
On August 9, 2019, Tentative Parcel Map No. NP2018-012 and associated Coastal
Development Permit No. CD2019-045 were approved for the subject property to
create one building site from two existing lots containing multiple ownerships. The
approved parcel map shall be recorded prior to issuance of building permits for this
project.
The subject neighborhood contains a variety of uses and development types, with no
uniform pattern or consistent design style. The block contains single-family
residences and duplexes containing two stories. The Lido Villas townhome project is
currently under construction across Via Lido to the west, which consists of three-story
structures designed to a height of approximately 34 feet. The St. James Episcopal
Church is located to the south at the corner of Via Lido and Via Malaga. The Lido
Park condominium building located further south near the Lido Bridge reaches a
height of more than 100 feet and contains approximately 55 dwelling units. Lastly,
commercial buildings are located to the north at the corner of Via Oporto and Via Lido
near Lido Marina Village. The proposed design, height, and bulk of the development
would not be out of scale with the existing development in the area, which varies in
height and bulk.
The proposed single-family dwelling and accessory structures conform to all
applicable development standards, including floor area limit, setbacks, height, and
off-street parking as evidenced by the project plans and illustrated in Table 1 below.
2
Stupin Residence
Zoning Administrator, September 12, 2019
Page 3
Tmplt: 07/25/19
Table 1 – Development Standards
Development Standard Standard Proposed
Setbacks (min.)
Front (Bay) 10 feet 10 feet
Sides 7.5 feet 7.5 feet
Front (Via Lido) 4 feet 4 feet
Allowable Floor Area (max.) 10,110 square feet 8,851 square feet
Allowable 3rd Floor Area (max.) N/A 1,097 square feet
Open Space (min.) 867 square feet > 2,600 square feet
Parking (min.) 3-car garage 4-car garage (total spaces)
Height (max.) 28 feet flat roof
33 feet sloped roof
28 feet flat roof
33 feet sloped roof
Hazards
A Coastal Hazards Report and Sea Level Rise Analysis was prepared by GeoSoils
Inc. dated April 24, 2019, for the project. The current maximum bay water elevation
is 7.72 NAVD88 (North American Vertical Datum of 1988 (NAVD88) and may
exceed the current 7.5 feet NAVD88 top of bulkhead elevation (8.8 feet NAVD88
with existing low height walls) during high tide or storm events. The report analyzes
future sea level rise scenarios assuming a 2.9-foot increase in the maximum water
level over the next 75 years (i.e. the life of the structure). Therefore, the sea level
is estimated to reach approximately 10.6 feet NAVD88 (the likely range for sea
level rise over 75-year design life of the structure based on low risk aversion
estimates for sea level rise provided by the State of California, Sea Level Rise
Guidance: 2018 Update). Once the existing seawall/bulkhead is raised per the
report’s recommendations, flooding, wave runup, and e rosion will not significantly
impact this property over the proposed 75 -year economic life of the development.
A waterproofing curb is also proposed to be constructed around the perimeter of
the dwelling that would protect against flooding up to an elevati on of 10.6 feet
(NAVD88). Flood shields (sand bags and other barriers) can be deployed across
the openings to protect and prevent flooding to the structure. The report concludes
that the proposed project will be safe from flooding hazards for the next 75 years
with the reinforced/raised bulkhead and a flood protection curb. Therefore, the
project has been conditioned to raise or cap the bulkhead and include a curb
structure up to 10.6 feet (NAVD88).
The finished floor elevation of the proposed single-family residence is 10.0 feet
(NAVD 88), which complies with the minimum 9.00 feet (NAVD88) elevation
standard. The Coastal Hazard Report concludes that the bay water elevation
(currently 7.7 feet NAVD88) will not exceed the proposed flood protection curb
around the single-family residence at 10.6 feet (NAVD88 datum) for the anticipated
75-year life of the structure.
3
Stupin Residence
Zoning Administrator, September 12, 2019
Page 4
Tmplt: 07/25/19
Pursuant to NBMC Section 21.30.030(C)(3)(i)(iv), the property owner will be required
to enter into an agreement with the City waiving any potential right to protection to
address situations in the future in which the development is threatened with damage
or destruction by coastal hazards (e.g., waves, erosion, and sea level rise). The
property owner will also be required to acknowledge any hazards present at the site
and unconditionally waive any claim to damage or liability against the decision
authority, consistent with NBMC Section 21.30.015(D)(3)(c). Both requirements are
included as conditions of approval that will need to be satisfied prior to final building
inspection, and prior to the issuance of building permits, respectively.
The property is located in an area known for the potential of seismic activity and
liquefaction. All projects are required to comply with the California Building Code
(CBC) and Building Division standards and policies. Geotechnical investigations
specifically addressing liquefaction are required to be reviewed and approved prior
to the issuance of a building permit. Permit issuance is also contingent on the
inclusion of design mitigation identified in the investigations. Construction plans are
reviewed for compliance with approved investigations and CBC prior to building
permit issuance.
Water Quality
The property is adjacent to the bay. Pursuant to Section 21.35.030 (Construction
Pollution Prevention Plan) of the Municipal Code, a Construction Pollution Prevention
Plan (CPPP) is required to implement temporary Best Management Practices
(BMP’s) during construction to minimize erosion and sedimentation and to minimize
pollution of runoff and coastal waters derived from construction chemicals and
materials. A CPPP has been provided and construction plans and activities will be
required to adhere to the CPPP.
Pursuant to Municipal Code Section 21.35.050, due to the proximity of the
development to the shoreline and the development containing more than 75 percent
of impervious surface area, a Water Quality and Hydrology Plan (WQHP) is required.
A preliminary WQHP has been prepared for the project by Forkert Engineering &
Surveying Inc. The WQHP includes a polluted runoff and hydrologic site
characterization, a sizing standard for BMPs, use of an LID approach to retain the
design storm runoff volume on site, and documentation of the expected effectiveness
of the proposed BMPs.
The project design addresses water quality with a construction erosion control plan
and a post construction drainage system that includes drainage and percolation
features designed to retain dry weather run-off and minor rain event run-off on-site.
Any water not retained on-site is directed to the City’s storm drain system.
4
Stupin Residence
Zoning Administrator, September 12, 2019
Page 5
Tmplt: 07/25/19
Public Access and Views
One new street parking space would be created as part of the project, which would
be available to the public.
The project site is located near Lido Park and Via Lido Bridge, which are designated
public viewpoints in the Coastal Land Use Plan and offer public views of the West
Lido Channel. These viewpoint areas contain benches for viewing the bay and
resting, but no other park amenities such as picnic areas or bathrooms. Site
evaluation revealed that the proposed three-story design is consistent with the
existing building heights in the general area, in particular the adjacent Lido Villas
project, the St. James Church, and Lido Park condos. Additionally, views of the site
from Lido Park are currently obscured by large trees along the sidewalk, and the bay
is not visible through the project site. The project site would remain visible from the
Lido Bridge viewpoint, but the bay would not be obstructed by the project, since it is
on the opposite side of the water.
The project will replace two existing multi-unit structures with a new single-family
home that complies with all applicable development standards, including the 10-foot
front setback along the bay and height limitations for the zoning district. The existing
interior setbacks between the two buildings would be removed and the new single-
family residence would be built across this area. There are no views through this area
from the bay or street at present. The two proposed side yard setbacks will be larger,
instead of approximately 3 feet they will be approximately 7.5 feet wide, providing
enhanced visual relief from the existing parking lot adjacent to the site.
The project design reduces the appearance of bulk and mass through the
incorporation of third floor setbacks, steep roof pitches, and open space areas. For
example, the Via Lido frontage includes a front porch on the first floor that provides
almost six additional feet of setback area from the street. The roof above this porch
area has a 6:12 pitch, providing additional visual relief. The roof areas along the side
property lines also have steep pitches, with the majority of the roofline in these areas
at 9:12 and 10:12 slopes. The third floor living space is setback approximately 16-24
feet from the Via Lido setback line, and the mass is concentrated within the center of
the building envelope. Lastly, as viewed from across the bay, the third floor is setback
more than 20 feet from the setback line with an open roof deck in the center of the
massing. Thus, the project incorporates design features beyond the requirements of
the code in order to provide visual relief and additional building modulation.
5
Stupin Residence
Zoning Administrator, September 12, 2019
Page 6
Tmplt: 07/25/19
ENVIRONMENTAL REVIEW
This project is exempt from the California Environmental Quality Act (CEQA) pursuant to
Section 15303 under Class 3 (New Construction or Conversion of Small Structures) of
the CEQA Guidelines, California Code of Regulations, Title 14, Chapter 3, because it has
no potential to have a significant effect on the environment.
Class 3 exempts the construction of up to three single-family residences in an urbanized
area. The proposed project includes the construction of a new 8,851-square-foot single-
family residence with attached garages.
PUBLIC NOTICE
Notice of this public hearing was published in the Daily Pilot, mailed to all owners and
residential occupants of property within 300 feet of the boundaries of the site (excluding
intervening rights-of-way and waterways), including the applicant, and posted on the
subject property at least 10 days before the scheduled hearing, consistent with the
provisions of the Municipal Code. Additionally, the item appeared on the agenda for this
meeting, which was posted at City Hall and on the City website.
APPEAL PERIOD:
This action shall become final and effective 14 days following the date the Resolution is
adopted unless within such time an appeal or call for review is filed with the Community
Development Director in accordance with the provisions of Title 21 (Local Coastal
Implementation Plan) of the Newport Beach Municipal Code. Final action taken by the City
may be appealed to the Coastal Commission in compliance with Section 21.64.035 of the
City’s certified LCP and Title 14 California Code of Regulations, Sections 13111 through
13120, and Section 30603 of the Coastal Act. For additional information on filing an appeal,
contact the Planning Division at 949-644-3200.
Prepared by:
______________________________
Liz Westmoreland, Assistant Planner
JM/law
Attachments: ZA 1 Draft Resolution
ZA 2 Vicinity Map
ZA 3 Project Plans
6
07/25/19
Attachment No. ZA 1
Draft Resolution
7
05-14-19
RESOLUTION NO. ZA2019-###
A RESOLUTION OF THE ZONING ADMINISTRATOR OF THE
CITY OF NEWPORT BEACH APPROVING COASTAL
DEVELOPMENT PERMIT NO. CD2019-033 TO CONSTRUCT A
NEW THREE-STORY SINGLE-FAMILY RESIDENCE AND TWO
ATTACHED GARAGES LOCATED AT 3312-3318, 3322, AND
3324 VIA LIDO (PA2019-100)
THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH HEREBY FINDS AS
FOLLOWS:
SECTION 1. STATEMENT OF FACTS.
1. An application was filed by Andrew and Julie Stupin, with respect to property located at
3312-3318, 3322, 3324 Via Lido, requesting approval of a coastal development permit.
2. The lots at 3312-3318, 3322, 3324 Via Lido are legally described as Lots 1 and 2 of Tract
1622, in the City of Newport Beach, County of Orange, State of California, as per Map
Recorded in Book 47, Miscellaneous Maps, in the Office of the County Assessor of Said
County. Except the Northwesterly 28 feet of said Lot 2. The property at 3322 and 3324 Via
Lido is legally described as Parcel 2 of PM2009-125, in the City of Newport Beach, County
of Orange, State of California, as per Map recorded in Book 373, Pages 21 & 22 or said
Parcel Maps in the Office of the County Recorder of Said County
3. The applicant requests a coastal development permit (CDP) to allow the construction of a
7,868 square-foot, three-story single-family residence with four garage spaces containing
983 square feet in aggregate. The project also includes the repair, reinforcement, and
raising of an existing bulkhead. No work is proposed bayward of the existing bulkhead.
The design includes a pool, spa, hardscape, walls, landscaping, and drainage facilities.
The project complies with all applicable development standards and no deviations are
requested.
4. The subject property is designated RM (Multiple-Unit Residential) by the General Plan
Land Use Element and is located within the RM (Multi-Unit Residential) Zoning District.
5. The subject properties are located within the coastal zone. The Coastal Land Use Plan
category is RM-D (Multiple Unit Residential - 20.0 - 29.9 du\ac) and it is located within the
RM (Multi-Unit Residential) Coastal Zone District.
6. On March 16, 2018, the Community Development director approved Staff Approval No.
SA2018-006 finding the demolition of a four-unit residential structure in compliance with
Zoning Code Chapter 20.34 and Local Coastal Program Implementation Plan Chapter
21.34 (Conversion or Demolition of Affordable Housing). The staff approval concluded that
there will be no conversion of residential to nonresidential uses, and none of the units are
and/or were occupied by low- and moderate income families or persons.
7. A public hearing was held on August 9, 2018, and a Tentative Parcel Map (NP2018-012)
and Coastal Development Permit (CD2018-045) were approved. The approval authorized
8
Zoning Administrator Resolution No. ####
Page 2 of 10
05-14-19
demolition of the existing two-unit residential condominium structure and four-unit
residential apartment structure, and the consolidation of the two properties into one parcel
for future use as a single-building site. The approval did not authorize any new
construction.
8. A public hearing was held on September 12, 2019, in the Corona del Mar Conference
Room (Bay E-1st Floor) at 100 Civic Center Drive, Newport Beach. A notice of time, place
and purpose of the hearing was given in accordance with the Newport Beach Municipal
Code. Evidence, both written and oral, was presented to, and considered by, the Zoning
Administrator at this hearing.
SECTION 2. CALIFORNIA ENVIRONMENTAL QUALITY ACT DETERMINATION.
1. This project is categorically exempt pursuant to Title 14 of the California Code of
Regulations Section 15303, Article 19 of Chapter 3, Guidelines for Implementation of the
California Environmental Quality Act (CEQA) under Class 3 (New Construction or
Conversion of Small Structures), because it has no potential to have a significant effect
on the environment.
2. Class 3 exempts the construction of up to three single-family residences in an urbanized
area. The proposed project includes the construction of a new 8,851-square-foot single-
family residence with attached garages.
3. The exceptions to this categorical exemption under Section 15300.2 are not applicable.
The project location does not impact an environmental resource of hazardous or critical
concern, does not result in cumulative impacts, does not have a significant effect on the
environment due to unusual circumstances, does not damage scenic resources within
a state scenic highway, is not a hazardous waste site, and is not identified as a historical
resource.
SECTION 3. REQUIRED FINDINGS.
In accordance with Section 21.52.015 (Coastal Development Permits, Findings and Decision)
of the Newport Beach Municipal Code, the following findings and facts in support of such
findings are set forth:
Finding:
A. Conforms to all applicable sections of the certified Local Coastal Program.
Facts in Support of Finding:
1. The proposed development complies with applicable residential development standards
including, but not limited to, floor area limitation, setbacks, height, and parking.
a. The maximum floor area limitation is 10,110 square feet and the proposed floor
area is 8,851 square feet.
9
Zoning Administrator Resolution No. ####
Page 3 of 10
05-14-19
b. The proposed development provides the minimum required setbacks, which are 4
feet along the front property line abutting Via Lido, 7.5 feet along each side property
line and 10 feet along the front property line facing Newport Bay.
c. The highest guardrail is less than 28 feet from established grade (10.12 feet
NAVD88) and the highest ridge is no more than 33 feet from established grade,
which comply with the maximum height requirements.
d. The project includes garage parking for a total of four vehicles, complying with the
minimum three-car garage parking requirement for single-family residences with
more than 4,000 square feet of habitable floor area.
2. The subject neighborhood contains a variety of uses and development types, with no
uniform pattern or consistent design style. The block contains single-family residences
and duplexes containing two stories. The Lido Villas townhome project is currently under
construction across Via Lido to the west, which consists of three-story structures
designed to a height of approximately 34 feet. The St. James Episcopal Church is
located to the south at the corner of Via Lido and Via Malaga. The Lido Park
condominium building located further south near the Lido Bridge reaches a height of
more than 100 feet and contains approximately 55 dwelling units. Lastly, commercial
buildings are located to the north at the corner of Via Oporto and Via Lido near Lido
Marina Village. The proposed design, height, and bulk of the development would not be
out of scale with the existing development in the area, which varies in height and bulk.
3. A Coastal Hazards Report and Sea Level Rise Analysis was prepared by GeoSoils, Inc.
dated April 24, 2019, for the project. The current maximum bay water elevation is 7.7
NAVD88 (North American Vertical Datum of 1988 (NAVD88) and may exceed the
existing 7.5 feet NAVD88 top of bulkhead elevation (8.8 feet NAVD88 with existing low
height walls) during high tide or storm events. The report analyzes future sea level rise
scenarios assuming a 2.9-foot increase in the maximum water level over the next 75
years (i.e. the life of the structure). Therefore, the sea level is estimated to reach
approximately 10.6 feet NAVD88 (the likely range for sea level rise over 75-year design
life of the structure based on low risk aversion estimates for sea level rise provided by
the State of California, Sea Level Rise Guidance: 2018 Update). Once the existing
seawall/bulkhead is raised per the report’s recommendations, flooding, wave runup, and
erosion will not significantly impact this property over the proposed 75 -year economic
life of the development. A waterproofing curb is also proposed to be constructed around
the perimeter of the dwelling that would protect against flooding up to an elevation of
10.6 feet (NAVD88). Flood shields (sand bags and other barriers) can be deployed
across the openings to protect and prevent flooding to the structure. The report
concludes that the proposed project will be safe from flooding hazards for the next 75
years with the reinforced/capped bulkhead and a flood protection curb. Therefore, the
project has been conditioned to raise or cap the bulkhead and include a curb structure
up to 10.6 feet (NAVD88).
4. The finished floor elevation of the proposed single-family residence is 10.0 feet
(NAVD88), which complies with the minimum 9.00 feet (NAVD88) elevation standard.
The Coastal Hazard Report concludes that the ba y water elevation (currently 7.7 feet
10
Zoning Administrator Resolution No. ####
Page 4 of 10
05-14-19
NAVD88) will not exceed the proposed flood protection curb around the single-family
residence at 10.6 feet (NAVD88 datum) for the anticipated 75-year life of the structure.
5. Pursuant to NBMC Section 21.30.030(C)(3)(i)(iv), the property owner will be required to
enter into an agreement with the City waiving any potential right to protection to address
situations in the future in which the development is threatened with damage or destruction
by coastal hazards (e.g., waves, erosion, and sea level rise). The property owner will also
be required to acknowledge any hazards present at the site and unconditionally waive any
claim to damage or liability against the decision authority, consistent with NBMC Section
21.30.015(D)(3)(c). Both requirements are included as conditions of approval that will need
to be satisfied prior to final building inspection, and prior to the issuance of building permits,
respectively.
6. The property is located in an area known for the potential of seismic activity and
liquefaction. All projects are required to comply with the California Building Code (CBC)
and Building Division standards and policies. Geotechnical investigations specifically
addressing liquefaction are required to be reviewed and approved prior to the issuance of
building permits. Permit issuance is also contingent on the inclusion of design mitigation
identified in the investigations. Construction plans are reviewed for compliance with
approved investigations and CBC prior to building permit issuance.
7. The property is located adjacent to the bay. A Construction Erosion Control Plan was
provided to implement temporary Best Management Practices (BMPs) during construction
to minimize erosion and sedimentation and to minimize pollution of runoff and coastal
waters derived by construction chemicals and materials. The project design also
addresses water quality through the inclusion of a post construction drainage system that
includes drainage and percolation features designed to retain dry weather and minor rain
event run-off on-site. Any water not retained on-site is directed to the City’s storm drain
system.
8. Pursuant to Municipal Code Section 21.35.050, due to the proximity of the development to
the shoreline and the development containing more than 75 percent of impervious surface
area, a Water Quality and Hydrology Plan (WQHP) is required. A preliminary WQHP has
been prepared for the project by Forkert Engineering & Surveying Inc. The WQHP includes
a polluted runoff and hydrologic site characterization, a sizing standard for BMPs, use of
an LID approach to retain the design storm runoff volume on site, and documentation of
the expected effectiveness of the proposed BMPs.
9. Proposed landscaping complies with Implementation Plan Section 21.30.075. A
condition of approval is included that requires drought-tolerant species. Prior to issuance
of building permits, the final landscape plans will be reviewed to verify invasive species
are not planted
10. The project site is located near Lido Park and Via Lido Bridge, which are designated public
viewpoints in the Coastal Land Use Plan and offer public views of the West Lido Channel.
These viewpoint areas contain benches for viewing the bay and resting, but no other park
amenities such as picnic areas or bathrooms. Site evaluation revealed that the proposed
three-story design is consistent with the existing building heights in the general area, in
11
Zoning Administrator Resolution No. ####
Page 5 of 10
05-14-19
particular the adjacent Lido Villas project, the St. James Church, and Lido Park condos.
Additionally, views of the site from Lido Park are currently obscured by large trees along
the sidewalk, and the bay is not visible through the project site. The project site would
remain visible from the Lido Bridge viewpoint, but views of the bay would not be obstructed
by the project since it is on the opposite side of the water.
11. The project will replace two existing multi-unit structures with a new single-family home
that complies with all applicable development standards, including the 10-foot front setback
along the bay and height limits for the zoning district. The existing interior setbacks
between the two buildings would be removed, and the structure would be built across this
area. There are no views through this area from the bay or street at present. The two
proposed side yard setbacks will be larger, instead of approximately 3 feet they will be
approximately 7.5 feet wide, providing enhanced visual relief from the existing parking lot
adjacent to the site.
Finding:
B. Conforms with the public access and public recreation policies of Chapter 3 of the
Coastal Act if the project is located between the nearest public road and the sea or
shoreline of any body of water located within the coastal zone .
Fact in Support of Finding:
1. The project site is located between the nearest public road and the sea or shoreline.
Implementation Plan Section 21.30A.040 requires that the provision of public access bear
a reasonable relationship between the requirement and the project’s impact, and be
proportional to the impact. In this case, the project replaces existing multi-family structures
with a new single-family residence. Therefore, the project does not involve a change in
land use, density or intensity that will result in increased demand on public access and
recreation opportunities. Furthermore, the project is designed and sited (appropriate
height, setbacks, etc.) so as not to block or impede existing public access opportunities.
The site is located adjacent to a CM (Commercial Recreational and Marine) Coastal Zoning
District, which contains a marine related use (Windward Sailing Club). The project site
would continue to be used for residential use, and would not include any features or
operational characteristics that could affect operations at the sailing club.
2. Vertical and lateral access to the water are available near the site by the entrance to the
Via Lido Bridge. There is a small access point by Lido Park with lateral access via a
boardwalk along the bay. The project is located on the opposite side of the Via Lido Bridge
and does not include any features that would obstruct access along these routes.
3. The existing development on-site includes two separate multi-family structures, each
utilizing a separate driveway. The separate driveways would be reconfigured and
consolidated as part of this project, which would result in a shorter curb cut. Therefore, a
new street parking space would be created as part of the project, which would be available
to the public.
12
Zoning Administrator Resolution No. ####
Page 6 of 10
05-14-19
SECTION 4. DECISION.
NOW, THEREFORE, BE IT RESOLVED:
1. The Zoning Administrator of the City of Newport Beach hereby approves Coastal
Development Permit No.CD2019-033, subject to the conditions set forth in Exhibit “A,”
which is attached hereto and incorporated by reference.
2. This action shall become final and effective 14 days following the date this Resolution
was adopted unless within such time an appeal or call for review is filed with the
Community Development Director in accordance with the provisions of Title 21 Local
Coastal Implementation Plan, of the Newport Beach Municipal Code. Final action taken
by the City may be appealed to the Coastal Commission in compli ance with Section
21.64.035 of the City’s certified LCP and Title 14 California Code of Regulations,
Sections 13111 through 13120, and Section 30603 of the Coastal Act.
PASSED, APPROVED, AND ADOPTED THIS 12TH DAY OF SEPTEMBER, 2019.
_____________________________________
Rosalinh Ung, Zoning Administrator
13
Zoning Administrator Resolution No. ####
Page 7 of 10
05-14-19
EXHIBIT “A”
CONDITIONS OF APPROVAL
1. The development shall be in substantial conformance with the approved site plan, floor
plans and building elevations stamped and dated with the date of this approval (except as
modified by applicable conditions of approval).
2. Prior to final inspection of building permits for the new residence, the existing seawall
shall be reinforced and capped to 10.6 feet (NAVD88) minimum in accordance with the
recommendations provided in the report prepared by GeoSoils Inc. on April 24, 2019
and as identified in the approved plans. All improvements at the property shall occur
landward of the existing bulkhead.
3. Prior to issuance of building permits, the project plans shall be updated to reflect that a
waterproofing curb will be constructed around the proposed residence as an adaptive
flood protection device up to 10.6 feet (NAVD88). Flood shields (sand bags and other
barriers) can be deployed across the openings to protect and prevent flooding to the
structure as necessary.
4. After demolition of existing residential structures and prior to the issuance of any building
permits for new construction, the Parcel Map authorized under NP2018-012 (CD2018-
045) shall be recorded with the County of Orange.
5. Prior to final building permit inspection, an agreement in a form approved by the City
Attorney between the property owner and the City shall be executed and recorded
waiving rights to the construction of future shoreline protection devices including the
repair and maintenance, enhancement, reinforcement, or any other activity affecting the
bulkhead, that results in any encroachment seaward of the authorized footprint of the
bulkhead or other shoreline protective device. The agreement shall be binding against
the property owners and successors and assigns.
6. Prior to the issuance of a building permit, the property owner shall submit a notarized
signed letter acknowledging all hazards present at the site, assuming the risk of injury
or damage from such hazards, unconditionally waiving any claims of damage against
the City from such hazards, and to indemnify and hold harmless City, its City Council, its
boards and commissions, officials, officers, employees, and agents from and against any
and all claims, demands, obligations, damages, actions, causes of action, suits, losses,
judgments, fines, penalties, liabilities, costs and expenses (including without limitation,
attorney’s fees, disbursements and court costs) of every kind and nature whatsoever which
may arise from or in any manner relate (directly or indirectly) to City’s approval of
development. This letter shall be scanned into the plan set prior to building permit issuance.
7. No demolition or construction materials, equipment debris, or waste, shall be placed or
stored in a location that would enter sensitive habitat, receiving waters, or a storm drain
or result in impacts to environmentally sensitive habitat areas, streams, the beach,
wetlands or their buffers. No demolition or construction materials shall be stored on
public property.
14
Zoning Administrator Resolution No. ####
Page 8 of 10
05-14-19
8. This approval does not authorize any new or existing improvements (including
landscaping) on State tidelands, public beaches, or the public right -of-way (except
improvements in the Via Lido right-of way that are required by Public Works).
9. This Coastal Development Permit does not authorize any development seaward of the
private property.
10. The applicant is responsible for compliance with the Migratory Bird Treaty Act. In
compliance with the (MBTA), grading, brush removal, building demolition, tree trimming,
and similar construction activities shall occur between August 16 and January 31,
outside of the peak nesting period. If such activities must occur inside the peak nesting
season from February 1 to August 15, compliance with the following is required to
prevent the taking of Native Birds pursuant to MBTA:
A. The construction area shall be inspected for active nests. If birds are observed flying
from a nest or sitting on a nest, it can be assumed that the nest is active. Construction
activity within 300 feet of an active nest shall be delayed until the nest is no longer
active. Continue to observe the nest until the chicks have left the nest and activity is no
longer observed. When the nest is no longer active, construction activity can continue
in the nest area.
B. It is a violation of state and federal law to kill or harm a native bird. To ensure
compliance, consider hiring a biologist to assist with the survey for nesting birds, and
to determine when it is safe to commence construction activities. If an active nest is
found, one or two short follow-up surveys will be necessary to check on the nest and
determine when the nest is no longer active.
11. Best Management Practices (BMP’s) and Good Housekeeping Practices (GHP’s) shall
be implemented prior to and throughout the duration of constru ction activity as
designated in the Construction Erosion Control Plan.
12. The discharge of any hazardous materials into storm sewer systems or receiving waters
shall be prohibited. Machinery and equipment shall be maintained and washed in
confined areas specifically designed to control runoff. A designated fueling and vehicle
maintenance area with appropriate berms and protection to prevent spillage shall be
provided as far away from storm drain systems or receiving waters as possible.
13. Debris from demolition shall be removed from work areas each day and removed from
the project site within 24 hours of the completion of the project. Stock piles and
construction materials shall be covered, enclosed on all sites, not stored in contact with
the soil, and located as far away as possible from drain inlets and any waterway.
14. Trash and debris shall be disposed in proper trash and recycling receptacles at the end
of each construction day. Solid waste, including excess concrete, shall be disposed in
adequate disposal facilities at a legal disposal site or recycled at a recycling facility.
15
Zoning Administrator Resolution No. ####
Page 9 of 10
05-14-19
15. Revisions to the approved plans may require an amendment to this Coastal
Development Permit or the processing of a new coastal development permit.
16. The project is subject to all applicable City ordinances, policies, and standards, unless
specifically waived or modified by the conditions of approval.
17. The applicant shall comply with all federal, state, and local laws. Material violation of
any of those laws in connection with the use may be cause for revocation of this Coastal
Development Permit.
18. This Coastal Development Permit may be modified or revoked by the Zoning
Administrator if determined that the proposed uses or conditions under which it is being
operated or maintained is detrimental to the public health, welfare or materially injurious
to property or improvements in the vicinity or if the property is operated or maintained
so as to constitute a public nuisance.
19. Prior to the issuance of building permits, the applicant shall submit a final construction
erosion control plan. The plan shall be subject to the review and approval by the Building
Division.
20. Prior to the issuance of building permits, the applicant shall submit a final drainage and
grading plan. The plan shall be subject to the review and approval by the Building
Division.
21. Prior to issuance of a building permit, a copy of the Resolution, including conditions of
approval Exhibit “A” shall be incorporated into the Building Division and field sets of
plans.
22. Prior to issuance of a building permit, the applicant shall submit to the Planning Division
an additional copy of the approved architectural plans for inclusion in the Coastal
Development file. The plans shall be identical to those approved by all City departments
for building permit issuance. The approved copy shall include architectural sheets only
and shall be reduced in size to 11 inches by 17 inches. The plans shall accurately depict
the elements approved by this Coastal Development Permit.
23. Prior to issuance of building permits, the final WQHP/WQMP shall be reviewed and
approved by the Building Division. Implementation shall be in compliance with the
approved CPPP and WQHP/WQMP and any changes could require separate review
and approval by the Building Division.
24. Prior to the issuance of building permits, the applicant shall submit a final landscape and
irrigation plan. These plans shall incorporate drought tolerant plantings, non -invasive
plant species and water efficient irrigation design. The plans shall be approved by the
Planning Division.
25. All landscape materials and irrigation systems shall be maintained in accordance with
the approved landscape plan. All landscaped areas shall be maintained in a healthy and
growing condition and shall receive regular pruning, fertilizing, mowing, and trimming.
16
Zoning Administrator Resolution No. ####
Page 10 of 10
05-14-19
All landscaped areas shall be kept free of weeds and debris. All irrigation systems shall
be kept operable, including adjustments, replacements, repairs, and cleaning as part of
regular maintenance.
26. Prior to the issuance of building permit, the applicant shall pay any unpaid administrative
costs associated with the processing of this application to the Planning Division.
27. Should the property be sold or otherwise come under different ownership, any future
owners or assignees shall be notified of the conditions of this approval by the current
property owner or agent.
28. This Coastal Development Permit No. CD2019-033 shall expire unless exercised within 24
months from the date of approval as specified in Section 21.54.060 (Time Limits and
Extensions) of the Newport Beach Municipal Code, unless an extension is otherwise
granted.
29. To the fullest extent permitted by law, applicant shall indemnify, defend and hold harmless
City, its City Council, its boards and commissions, officials, officers, employees, and agents
from and against any and all claims, demands, obligations, damages, actions, causes of
action, suits, losses, judgments, fines, penalties, liabilities, costs and expenses (including
without limitation, attorney’s fees, disbursements and court costs) of every kind and nature
whatsoever which may arise from or in any manner relate (directly or indirectly) to City’s
approval of Stupin Residence including, but not limited to, Coastal Development Permit
No. CD2019-033 (PA2019-100). This indemnification shall include, but not be limited to,
damages awarded against the City, if any, costs of suit, attorneys' fees, and other
expenses incurred in connection with such claim, action, causes of action, suit or
proceeding whether incurred by applicant, City, and/or the parties initiating or bringing such
proceeding. The applicant shall indemnify the City for all of City's costs, attorneys' fees,
and damages, which City incurs in enforcing the indemnification provisions set forth in this
condition. The applicant shall pay to the City upon demand any amount owed to the City
pursuant to the indemnification requirements prescribed in this condition.
17
07/25/19
Attachment No. ZA 2
Vicinity Map
18
07/25/19
VICINITY MAP
Coastal Development Permit No. CD2019-033
PA2019-100
3312-3318, 3322 and 3324 Via Lido
Subject Property
19
07/25/19
Attachment No. ZA 3
Project Plans
20
Name
Elevation
A101
1
SIM
Room name
150 SF
101
1i
?
90 00' 00"
Distance
N E
1
1
A101
SIM
R @ 7 1/2"20
1i
NORTH ARROW
PROPERTY LINE TAG
SECTION INDICATOR
ROOM TAG (NAME / AREA)
CALL-OUT TAG
ELEVATION INDICATOR
KEYNOTE TAG
WINDOW TAG
DOOR TAG
WALL TAG
REVISION FLAG
STAIR TAG (NO. OF RISER & HEIGHT)
ALUMINUM
CONCRETE
EARTH
GYPSUM -PLASTER
INSULATION -RIGID
MASONRY -BRICK/STONE
MASONRY -CONCRETE BLOCK
PLYWOOD / GLU-LAM TIMBER
SAND
STEEL
WOOD
JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT
T-1.0
7/19/19
201837TITLE SHEETSTUPIN RESIDENCE
STUPIN RESIDENCEAMDREW & JULIE STUPINC/O. COASTLINE REALESTATE INVESTMENTS215TH STREETHUNTINGTON BEACHCA 92648CDP
3322 VIA LIDO, NEWPORT BEACH, CA 92663JUSTIN JONHSTON
JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT
T-1.0
7/19/19
201837TITLE SHEETSTUPIN RESIDENCE
STUPIN RESIDENCEAMDREW & JULIE STUPINC/O. COASTLINE REALESTATE INVESTMENTS215TH STREETHUNTINGTON BEACHCA 92648CDP
3322 VIA LIDO, NEWPORT BEACH, CA 92663JUSTIN JONHSTON
REF. 8/T-1.0FLOOR AREA
HEIGHT
NBMC (NEWPORT BEACH MUNICIPAL CODE)
CALIFORNIA CODES: 2016 CRC, 2016 CFC, 2016 CEC,
2016 CPC, AND 2016 CMC, 2016 CAL GREEN
R-3 / U
1-HR.
CODES:
OCCUPANCY CLASSIFICATION
OCCUPANCY SEPARATIONS (GARAGE)
OCCUPANT LOAD
TYPE OF CONSTRUCTION
OWNER: ARCHITECT:
N/AALLOWABLE BLDG. AREA
(PER CBC TBL. 503)
FLOOR & FLOOR-CEILINGS N/A
BRANDON ARCHITECTS, INC.
151 KALMUS DR. STE. G-1
COSTA MESA, CA 92626
P: 714.754.4040
WWW.BRANDONARCHITECTS.COM
STRUCTURAL ENGINEER:CIVIL ENGINEER:
GENERAL CONTRACTOR:LANDSCAPE DESIGNER:
SURVEYOR:SOILS ENGINEER:
SITE
1 UNIT
V-B -SPRK'R.
3 STORY
THE PROPERTY IS LOCATED IN NEWPORT BEACH, CA ON THE WATER AT BALBOA PENINSULA ON THE WEST SIDE OF THE BAY NEAR THE
INTERSECTION OF VIA LIDO AND VIA MALAGA. THE LOT/PARCEL IS APPROXIMATELY 93.5’WIDE BY 90’DEEP, ZONED AS RM (MULTI-UNIT RESIDENTIAL)
AND APPROXIMATELY IS 11,098 S.F.. THE PROPERTY PREVIOUSLY WAS TWO SEPARATE LOTS THAT CONSOLIDATED AND EXISTING MULTI-FAMILY
RESIDENCES AND GARAGES HAVE BEEN DEMOLISHED/WILL BE. CLIENT PROPOSES TO BUILD A NEW 3-STORY SINGLE FAMILY RESIDENCE OF APPX.
7,876 S.F. WITH TWO 2-CAR GARAGES OF APPX. 983 S.F. THE PROGRAM MAY INCLUDE BUT NOT BE LIMITED TO THE FOLLOWING: LARGE EAT-IN
KITCHEN W/. ISLAND & BUTLER’S PANTRY, GREAT ROOM WITH A FIREPLACE, DINING AREA, POWDER ROOM,ELEVATOR, A LARGE MASTER SUITE WITH
A FIREPLACE, GENEROUS MASTER BATH WITH WALK-IN CLOSETS, 4 SECONDARY BEDROOMS WITH ATTACHED BATHS & CLOSETS, LAUNDRY ROOM, A
HOME OFFICE/GYM, A DEN/GAME ROOM, AND A FAMILY ROOM. PARKING FOR 5 CARS (ONE CARPORT) WILL BE ACCOUNTED FOR WITH ACCESS OFF OF
VIA LIDO. THE PATIO/OPEN COVERED AREA ARRANGED WITH A STRONG CONNECTION TO INDOOR LIVING SPACES. OUTDOOR AMENITIES INCLUDE A
LAP POOL (PARALLEL TO THE BAY) AND A SPA, FIRE FEATURES, A BBQ/OUTDOOR KITCHEN AREA, AND COMFORTABLE OUTDOOR COVERED LOUNGE
AREA (LOGGIA) AND A LARGE ENTERTAINING ROOF DECK. THE PROJECT IS OF A TRANSITIONAL/INDUSTRIAL BEACH HOUSE DESIGN WITH AMPLE
INDOOR/OUTDOOR LIVING SPACES INTEGRATED WITH A MODERN ‘OPEN’LIVING PLAN WITH LOTS OF GLAZING WHICH STRIVES TO MAXIMIZE LIGHT AND
WATER VIEWS FROM LIVING SPACES AS WELL AS OUTDOOR PATIOS, COURTYARDS, AND DECKS. THE EXTERIOR MATERIALS WILL BE OF RICH QUALITY
AND HIGH DURABILITY; TO BE CONSISTING PRIMARILY OF, NATURAL STONE VENEER, SMOOTH STUCCO VENEER, NATURAL SLATE, AND STANDING
SEAM METAL ROOFING, EXPANSIVE STEEL DOORS AND WINDOWS, AND THE USE OF STEEL AND WOOD DECORATIVE ACCENTS.
FIRE SPRINKLER: NFPA 13D YES
DEFERRED SUBMITTALS
8PROJECT STATISTICS 5 3 1
249
10
AGENCIES & PUBLIC SERVICES
VICINITY MAP/ PROJECT DESCRIPTION
MATERIAL LEGEND
ANNOTATION LEGEND CODE REVIEW SHEET LISTSITE INFORMATION11
7
6SPECIAL INSPECTIONS
PROJECT DIRECTORYPROJECT DIRECTORY
PROJECT DESCRIPTION:
STUPIN RESIDENCE
BRANDON ARCHITECTS, INC.ANDREW & JULIE STUPIN
C/O. COASTLINE REAL ESTATE
INVESTMENTS
215TH STREET
HUNTINGTON BEACH, CA 92648
PATTERSON CUSTOM HOMES
ANDREW PATTERSON
15 CORPORATE PLAZA, SUITE 150
NEWPORT BEACH, CA 92660
P: 949.723.1800
DAVID A. PEDERSEN, INC.
DAVID PEDERSEN
20271 ACACIA ST., SUITE 120
NEWPORT BEACH, CA 92660
P: 949.251.8999
F: 949.251.0899
BUILDING AREA SCHEDULE
NAME AREA COMMENTS
FIRST FLOOR AREA 2948 SF
SECOND FLOOR AREA 3823 SF
THIRD FLOOR AREA 1097 SF
7868 SF
GARAGE 2 487 SF
GARAGE 1 496 SF
983 SF
GRAND TOTAL 8850 SF
OUTDOOR AREA SCHEDULE
NAME AREA COMMENTS
REAR YARD 521 SF PARTIAL COVER
ENTRY 255 SF COVERED
LOGGIA 283 SF COVERED
PATIO 336 SF COVERED
DRIVEWAY 251 SF
REAR YARD 2 416 SF
DRIVEWAY 2 245 SF
MASTER BALCONY 138 SF
OFFICE/GYM BALCONY 181 SF
GRAND TOTAL 2628 SF
APEX LAND SURVEYING, INC.
PAUL CRAFT
C: 714.488.5006
APEXLSINC@GMAIL.COM
FMH ENGINEERING, INC.
FADY HAKIM, PE
410 GODDARD, SUITE 200
IRVINE, CA 92618
P: (949) 245 -8000
WWW.FMHENGINEERING.COM
COAST GEOTHECHNICAL, INC.
MING-TRANG CHEN
1200 W. COMMONWEALTH AVE.
FULLERTON, CA 92833
P: 714.870.1211
E: COASTGEOTEC@SBCGLOBAL.NET
FORKERT ENGINEERING &
SURVEYIN, INC.
THOMAS M. RUIZ, P.E.
22311 BROOKHURT ST., STE 203
HUNTINGTON BEACH, CA 92646
P: 714.963.6793
INTERIOR DESIGNER:
DETAILS A DESIGN FIRM
KEVIN SMITH
9272 JERONIMO ROAD, SUITE 109
IRVINE, CA 92618
P:949.716.1880
DIG ALERT: 1.800.227.2600
SOUTHERN CALIFORNIA EDISON: 1.714.895.0246
SOUTHERN CALIFORNIA GAS: 1.800.427.2000
CITY WATER & SEWER: 1.949.644.3011
PACIFIC BELL TELEPHONE: 1.800.750.2355
CITY OF NEWPORT BEACH
PUBLIC WORKS DEPT.: 1.949.644.3311
CITY OF NEWPORT BEACH PLANNING DEPT.:
GENERAL INFOMATION: 1.949.644.3200
ZONING INFORMATION:1.949.644.3204
CITY OF NEWPORT BEACH BUILDING DEPT.:
GENERAL:1.949.644.3275
PERMITS:1.949.644.3288
INSPECTIONS:1.949.644.3255
NEWPORT BEACH FIRE DEPARTMENT:1.949.644.3106
ORANGE COUNTY HEALTH SERVICES:1.714.834.3882
NOTE: DEFERRED SUBMITTALS TO BE REVIEWED BY PROJECT ARCHITECT OR
ENGINEER OF RECORD AND CERTIFIED PRIOR TO SUBMITTAL TO LOCAL AGENCY
FOR REVIEW.
C.N.B. NOTE:CHRISTOPHER BRANDON, PRINCIPAL ARCHITECT IS THE DESIGN
PROFESSIONAL IN RESPONSIBLE CHARGE OF THE PROJECT, RESPONSIBLE FOR
REVIEWING AND COORDINATING SUBMITTAL DOCUMENTS PREPARED BY OTHERS,
INCLUDING PHASED AND DEFERRED SUBMITTAL ITEMS, FOR COMPATIBILITY WITH
THE DESIGN OF THE BUILDING. (NBMC 15.02.010)
1.LANDSCAPE PLAN; BBQ; FIRE PIT; ACCESSORY STRUCTURES, MASONRY OR
CONCRETE WALLS/FENCES; RETAINING WALLS OVER 4 FT. HIGH FROM THE
BOTTOM OF THE FOUNDATION TO THE TOP OF WALL; UNDER SEPERATE
SUBMITTAL (FOR H.O.A. PURPOSES).
2. POOLS, SPAS, WALLS, FENCES, PATIO COVERS AND OTHER FREESTANDING
STRUCTURES REQUIRE SEPARATE REVIEWS AND PERMITS.
3. SUBMIT SOUND ATTENUATION DESIGN FOR HVAC EQUIPMENT PER ARI STD. 275.
SOUND LEVEL NOT TO EXCEED 50dBA (55dBA WITH TIMER, 65dBA WITH TIMER AND
NEIGHBORS CONSENT). LOCATION OF MEASUREMENT TO BE AT ADJACENT
PROPERTY PATIO OR OPENING.
4. A CAL-OSHA PERMIT IS REQUIRED FOR EXCAVATIONS DEEPER THAN 5' AND FOR
SHORING AND UNDERPINNING. CONTRACTOR TO PROVIDE A COPY OF OSHA
PERMIT.
5. FIRE SPRINKLERS REQUIRED, CONSTRACTOR TO SUBMIT FIRE SPRINKLER
DRAWINGS FOR ARCHITECT'S APPROVAL PRIOR TO SUBMITTING TO CITY. OBTAIN
FIRE SPRINKLER PERMIT PRIOR TO CALLING FOR ROOF SHEATHING INSPECTION.
6. GLASS GUARD/HANDRAILS
7. SEAWALL REPAIR UNDER SEPARATE SUBMITTAL & PERMIT, NECESSARY
REPAIRS SHALL BE DONE IN CONJUNCTION W/. BUILDING NEW STRUCTURE.
1. REF. STRUCT. SHTS. FOR SPECIAL INSPECTION BY ENGINEER OF RECORD
2. HERS VERIFICATION REQUIRED, REF. T-24 ENERGY CALCULATIONS
LEGAL DESCRIPTION:
LOT INFORMATION:
ZONED: RM
SITE AREA:8,160.15 S.F. BUILDABLE AREA: 5,778.25 S.F.
TOTAL ALLOWABLE AREA: 1.75 X 5,778.25 S.F. = 10,110.19 S.F.
MIN. OPEN VOLUME REQ'D: 5,778.25 S.F. X 15% = 866.74 S.F.
OPEN VOLUME PROVIDED: 2,628 S.F.> 866.74 S.F.
EXISTING BUILDING INFORMATION:
THE EXISTING TWO-UNIT RESIDENTIAL CONDOMINIUM STRUCTURE
AND FOUR-UNIT RESIDENTIAL APARTMENT STRUCTURE DEMOLISHED,
REF. ZA2018-097, NP2018-012, CD2018-045, AND PA2018-100
ZONING INFORMATION:
FRONT SETBACK: 4 FT.
OCEAN FRONT SETBACK: 10 FT.
LEFT SETBACK: 7'-6" FT. (0.08 X 93.57' = 7.48')
RIGHT SETBACK: 7'-6" FT. (0.08 X 93.57' = 7.48')
APN: 423-123-12 & 423-123-21
THE PROPERTY AT 3312-3318 VIA LIDO IS LEGALLY DESCRIBED AS LOTS
1 AND 2 OF TRACT 1622, IN THE CITY OF NEWPORT BEACH, COUNTY OF
ORANGE, STATE OF CALIFORNIA, AS PER MAP RECORDED IN BOOK 47,
MISCELLANEOUS MAPS, IN THE OFFICE OF THE COUNTY ASSESSOR OF
SAID COUNTY. EXCEPT THE NORTHWESTERLY 28 FEET OF SAID LOT 2.
THE PROPERTY AT 3322 AND 3324 VIA LIDO IS LEGALLY DESCRIBED AS
PARCEL 2 OF PM2009-125, IN THE CITY OF NEWPORT BEACH, COUNTY OF
ORANGE, STATE OF CALIFORNIA, AS PER MAP RECORDED IN BOOK 373,
PAGES 21 & 22 OR SAID PARCEL MAPS IN THE OFFICE OF THE COUNTY
RECORDER OF SAID COUNTY. PROPERTIES CONSOLIDATED TO ONE
PARCEL REF. ZA2018-097, NP2018-012, CD2018-045, AND PA2018-100
3322 VIA LIDO, NEWPORT BEACH, CA 92663
LANDSCAPE AREA SCHEDULE
NAME AREA COMMENTS
PLANTED 745 SF
GRAND TOTAL 745 SF
TITLE 24 CONSULTANT:
GMEP ENGINEERS
JUSTIN BOSTWICK, PM
26439 RANCHO PKWY S #120
LAKE FOREST, CA 92630
P: 949-267-9095
NO. REVISION DATENO. REVISION DATE
TOTAL LIVING
TOTAL GARAGE
GRAND TOTAL
SHEET #DRAWING TITLE
T-1.0 TITLE SHEET
T-1.1 GENERAL ARCHITECTURAL NOTES
T-1.2 SUPPLEMENTAL NOTES & DOCUMENTS
SUR TOPOGRAPHIC SURVEY
A-0.0 ARCHITECTURAL SITE PLAN
A-0.3 GRADE PLANE EXHIBIT
A-0.4 AREA PLANS
SW-0 GENERAL NOTES (FOR REFERENCE)
SW-1 SITE PLAN & ELEVATION (FOR REFERENCE)
SW-2 DETAILS (FOR REFERENCE)
SW-3 DETAILS (FOR REFERENCE)
C2 PRECISE GRADING PLAN
C4 EROSION CONTROL PLAN
L-PLANTING PLAN
A-1.0 3-DIMENSIONAL VIEWS
A-2.0 MAIN LEVEL FLOOR PLAN
A-2.1 SECOND LEVEL FLOOR PLAN
A-2.2 THIRD LEVEL FLOOR PLAN
A-3.0 ROOF PLAN
A-4.0 EXTERIOR ELEVATIONS & MATERIAL SCHEDULE
A-4.1 EXTERIOR ELEVATION
A-5.0 BUILDING SECTIONS
A-5.1 BUILDING SECTIONS
A-5.2 BUILDING SECTIONS
A-5.3 BUILDING SECTIONS
A-5.4 BUILDING SECTIONS
A-5.5 BUILDING SECTIONS
GRAND TOTAL
GRAND TOTAL
21
JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT
T-1.1
7/19/19
201837GENERAL ARCHITECTURAL NOTESSTUPIN RESIDENCE
STUPIN RESIDENCEAMDREW & JULIE STUPINC/O. COASTLINE REALESTATE INVESTMENTS215TH STREETHUNTINGTON BEACHCA 92648CDP
3322 VIA LIDO, NEWPORT BEACH, CA 92663JUSTIN JONHSTON
1GENERAL NOTES
ABBREVIATIONS 2
DEFINITIONS:
SPECIFICATIONS SHALL MEAN: WRITTEN SPECIFICATIONS IN THE PLANS OR THE "PROJECT MANUAL" (IF PROVIDED FOR THIS PROJECT)
CONTRACT DOCUMENTS SHALL MEAN: WORKING DRAWINGS APPROVED FOR BUILDING PERMIT, PLUS ANY CHANGE ORDERS OR ADDENDA TO SAME.
CONTRACTOR SHALL MEAN:
AMDREW & JULIE STUPIN, C/O. COASTLINE REAL ESTATE
ARCHITECT SHALL MEAN: BRANDON ARCHITECTS, INC., CHRISTOPHER BRANDON PRINCIPAL
OWNER SHALL MEAN:
(AS USED IN THESE SPECIFICATIONS)
LICENSED GENERAL CONTRACTOR HIRED TO PERFORM THE WORK UNDER THIS CONTRACT
1. CODES/GENERAL PROVISIONS:
ALL WORK, CONSTRUCTION AND MATERIALS SHALL COMPLY WITH ALL PROVISIONS OF THE APPLICIABLE BUILDING CODES AND WITH OTHER RULES, REGULATIONS AND ORDINANCES GOVERNING THE PLACE OF
CONSTRUCTION. IT IS THE RESPONSIBILITY OF THE CONTRACTOR, SUB-CONTRACTORS, AND ANYONE SUPPLYING LABOR AND/OR MATERIAL TO BRING TO THE ATTENTION OF THE ARCHITECT (VERBALLY AND
IN WRITING) ANY KNOWN DISCREPANCIES OR CONFLICT BETWEEN THE REQUIREMENTS OF THESE CODES AND THE CONTRACT DOCUMENTS (DRAWINGS). THE APPLICABLE CODES SHALL INCLUDE, BUT SHALL
NOT BE LIMITED TO THOSE AS LISTED IN "CODE REVIEW" BOX. (T-1)
ALL WORK SHALL BE PERFORMED SO AS TO COMPLY WITH ALL LEGAL AND INDUSTRY REQUIREMENTS AND STANDARDS INCLUDING THE FOLLOWING:
THE BUILDING CODES, 2016 EDITIONS, AS ADOPTED BY CALIFORNIA, ALL APPLICABLE RELATED SPECIALTY CODES.
THE FUNCTIONALITY STANDARDS SET FORTH IN TITLE 7 OF THE CALIFORNIA CIVIL CODE (THE "RIGHT TO REPAIR ACT").
ANY WORK TIME RESTRICTIONS IMPOSED BY THE CITY OF NEWPORT BEACH.
THE MANUFACTURER'S REQUIREMENTS OF RECOMMENDATIONS FOR ANY INCORPORATED PRODUCTS.
2. FEES:
CONTRACTOR AND HIS SUB-CONTRACTORS SHALL OBTAIN AND PAY FOR ALL PERMITS, LICENSES, CONSTRUCTION TAXES AND FEES REQUIRED BY CITY, COUNTY AND STATE LAWS EXCEPT THE GENERAL BUILDING PLANCHECK FEE AND
REQUIRED REFUNDABLE DEPOSITS WHICH WILL BE PAID BY THE OWNER. CONTRACTOR SHALL ARRANGE FOR ALL METER INSTALLATIONS AND PAY ALL FEES FOR SAID METERS. CONTRACTOR SHALL PROVIDE TEMPORARY TOILET
FACILITIES AND EROSION CONTROL MEASURES AS REQUIRED BY STATE AND LOCAL BUILDING CODE.
3. CONTRACTOR'S SURVEY:
CONTRACTOR SHALL VISIT THE JOB SITE AND BE RESPONSIBLE FOR HAVING COMPLETE KNOWLEDGE OF EXISTING CONDITIONS. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS WITH THOSE SHOWN ON THE DRAWINGS AND SHALL
VERIFY GRADES, CONDITIONS AND DIMENSIONS PRIOR TO COMMENCING DEMOLITION AND CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY VERBALLY AND IN WRITING OF DISCREPANCIES BETWEEN ACTUAL
CONDITIONS AND THOSE DEPICTED IN THE CONTRACT DOCUMENTS. CONTRACTOR SHALL NOTIFY ARCHITECT IMMEDIATELY VERBALLY AND IN WRITING OF ANY DISCREPANCIES FOUND WITHIN THE DRAWINGS AND SPECIFICATIONS.
4. COORDINATION OF CONSTRUCTION:
CONTRACTOR IS SOLELY RESPONSIBLE FOR THE ACCURACY OF DETAILS; FOR CONFIRMING AND COORDINATING ALL QUANTITIES AND DIMENSIONS; FOR SELECTING FABRICATION PROCESSES; FOR TECHNIQUES OF ASSEMBLY AND
PERFORMANCE OF ALL WORK IN A SAFE AND SATISFACTORY MANNER. CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF ALL WORK INCLUDING THAT OF THE SUB-CONTRACTORS. CONTRACTOR SHALL PROVIDE
SUPERVISION OF THE JOB DURING ALL PHASES OF CONSTRUCTION ACTIVITIES. A COMPETENT SUPERINTENDENT SHALL BE SELECTED BY THE CONTRACTOR AND SHALL BE IN CHARGE OF THE JOB UNTIL ITS COMPLETION. CONTRACTOR
AGREES TO BIND EVERY SUB-CONTRACTOR BY THE TERMS OF THE CONTRACT AS FAR AS SUCH TERMS ARE APPLICABLE TO THE SUB-CONTRACTOR'S WORK.
5. CLEAN-UP:
ALL SUB-CONTRACTORS SHALL BE RESPONSIBLE FOR THE DAILY REMOVAL OF ALL DEBRIS ACCUMULATED AS A RESULT OF THEIR OPERATIONS. ALL SCRAP DEBRIS AND OTHER EXCESS MATERIAL SHALL BE LAWFULLY REMOVED FROM THE
SITE, UNLESS OTHERWISE DIRECTED BY THE CONTRACTOR.
6. TESTS AND PERMITS:
CONTRACTOR SHALL ARRANGE FOR, AND SECURE REQUIRED TESTS, PERMITS AND INSPECTIONS, AND SHALL BEAR COSTS FOR SAME.
7. GUARANTEES:
CONTRACTOR SHALL GUARANTEE ALL WORK, MATERIALS AND PRODUCTS FOR ONE YEAR AFTER THE DATE OF ACCEPTANCE OF THE WORK AND CONTRACTOR SHALL REPAIR OR REPLACE, OR CAUSE TO BE REPAIRED OR REPLACED ANY
OR ALL SUCH WORK TOGETHER WITH ANY OTHER WORK WHICH MAY BE DISPLACED IN DOING SO, THAT MAY PROVE DEFECTIVE WITHIN ONE YEAR, WITHOUT ADDITIONAL EXPENSE; ORDINARY WEAR AND TEAR, UNUSUAL ABUSE OR
NEGLECT IS EXCEPTED. EXCEPTIONS TO ONE YEAR GUARANTEE ARE SPECIFIED IN OTHER SECTIONS OF THE PROJECT MANUAL OR DRAWINGS. STATE LAW, OR MANUFACTURER'S GUARANTEE SHALL GOVERN IF LENGTH AND TYPES OF
GUARANTEES ARE MORE STRICT OR FOR LONGER PERIODS.
IT IS UNDERSTOOD BY CONTRACTOR THAT IT IS HIS RESPONSIBILITY TO PROVIDE MATERIALS AND CONSTRUCTION WHICH WILL YIELD A REASONABLE VALUE OVER A PERIOD OF TIME WHICH MAY EXCEED THE SPECIFIED GUARANTEE AND
WARRANTY PERIODS.
CONTRACTOR SHALL BE RESPONSIBLE FOR A WEATHER TIGHT BUILDING, FREE FROM DEFECTS OF MATERIALS AND WORKMANSHIP. EACH SUB-CONTRACTOR SHALL PROVIDE A WRITTEN GUARANTEE STATING THAT WORK EXECUTED BY
HIM IS FREE AND WILL REMAIN FREE FROM DEFECTS OF MATERIALS AND WORKMANSHIP FOR ONE YEAR FROM DATE OF ACCEPTANCE OF HIS WORK BY OWNER, AND THAT REPAIR AND REPLACEMENT OF SUCH DEFECTIVE WORK AND ALL
OTHER WORK DAMAGED AS A RESULT THEREBY WILL BE EXECUTED IN A TIMELY MANNER AT THE CONVENIENCE OF THE OWNER AND WITHOUT COST TO OWNER.
8. WAIVER OF LIENS:
CONTRACTOR SHALL PROVIDE CERTIFIED RELEASE OF LIENS BY ALL SUB-CONTRACTORS AND SUPPLIERS, OR ANYONE PROVIDING MATERIALS AND/OR LABOR AS THEY BECOME AVAILABLE.
9. ROLL OF ARCHITECT DURING CONSTRUCTION:
THE ARCHITECT WILL NOT ACT AS THE OWNER'S REPRESENTATIVE DURING CONSTRUCTION. ARCHITECT WILL ADVISE AND CONSULT WITH OWNER. ARCHITECT WILL OBSERVE CONSTRUCTION PER HIS AGREEMENT WITH OWNER AND
RENDER INTERPRETATIONS NECESSARY FOR THE PROPER EXECUTION OR PROGRESS OF THE WORK IN ACCORDANCE WITH THE INTENT OF THE PLANS AND SPECIFICATIONS. ARCHITECT WILL NOT BE RESPONSIBLE OR HAVE CONTROL OR
CHARGE OVER THE ACTS OR OMISSIONS, CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS, OF THE CONTRACTOR, SUB-CONTRACTORS, OR ANY OF THEIR
AGENTS OR EMPLOYEES, OR ANY OTHER PERSONS PERFORMING ANY OF THE WORK.
ANY VERBAL INSTRUCTION OR AUTHORIZATION THAT IS CONFIRMED BY LETTER, MEETING NOTE, MEMORANDA, OR THE LIKE, (WITH A COPY SENT TO THE OWNER, OR THE OWNER'S REPRESENTATIVE) & THERE IS NO EXCEPTION TAKEN
WITHIN (10) CALENDAR DAYS, SHALL BE DEEMED EQUIVALENT TO RECEIPT OF WRITTEN INSTRUCTION, APPROVAL AND AUTHORIZATION FROM THE OWNER.
10. A.I.A. GENERAL CONDITIONS:
THE CURRENT GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION PUBLISHED BY THE AMERICAN INSTITUTE OF ARCHITECTS SHALL APPLY AS THOUGH IT WERE PART OF THESE DOCUMENTS UNLESS SPECIFICALLY MODIFIED IN
THE OWNER/CONTRACTOR AGREEMENT. A COPY OF SAID GENERAL CONDITIONS MAY BE OBTAINED FROM THE ARCHITECT UPON REQUEST. THE NOTES CONTAINED IN THESE "GENERAL NOTES" ON THIS SHEET ARE INTENDED TO
SUMMARIZE AND COMPLIMENT THE A.I.A. GENERAL CONDITIONS. THE A.I.A. GENERAL CONDITIONS SHALL TAKE PRECEDENCE OVER THESE NOTES SHOULD A CONFLICT IN WORDING OCCUR.
11. EXTRAS:
OWNER MAY ORDER EXTRA WORK OR MAKE CHANGES BY ALTERING, ADDING TO OR DEDUCTING FROM THE WORK, THE CONTRACT SUM BEING ADJUSTED TO THE MUTUAL SATISFACTION OF THE OWNER, ARCHITECT AND CONTRACTOR.
BEFORE ANY CHANGES ARE BEGUN, THE ADDED OR DEDUCTED SUM SHALL BE PRESENTED TO OWNER IN WRITING FOR APPROVAL.
12. SUBSTITUTIONS:
SUBSTITUTIONS OF MATERIALS OR METHODS PROPOSED BY THE CONTRACTOR OR HIS SUB-CONTRACTORS CONTRARY TO DRAWINGS AND SPECIFICATIONS SHALL BE SUBMITTED TO ARCHITECT IN WRITING FOR APPROVAL OR DENIAL. IF
MORE THAN ONE MANUFACTURER IS SPECIFIED IN THE PLANS OR SPECIFICATIONS, IT SHALL BE THE CONTRACTOR'S OPTION TO SELECT THE ONE WHICH HE MAY DESIRE. IF MORE THAN ONE FINISH OR STYLE IS AVAILABLE IN THE ITEM
SPECIFIED, CONTRACTOR SHALL BE OBLIGATED TO NOTIFY ARCHITECT VERBALLY AND IN WRITING OF THIS FACT FOR ARCHITECT'S AND OWNER'S DECISION. WHERE THE TERM "OR EQUAL" IS USED IN DRAWINGS OR SPECS IT SHALL BE
UNDERSTOOD THAT THE REFERENCE IS MADE SUBJECT TO THE RULING AND JUDGMENT OF THE ARCHITECT AND SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW AND APPROVAL. ACTUAL SAMPLES OF THE SUBSTITUTIONS SHALL
ALSO BE SUBMITTED TO THE ARCHITECT FOR REVIEW AND APPROVAL.
13. INSURANCE:
CONTRACTOR SHALL CARRY GENERAL LIABILITY INSURANCE WITH BROADFORM PROPERTY DAMAGE ENDORSEMENT AND CONTINGENT LIABILITY ENDORSEMENT. OWNER AND ARCHITECT SHALL BE LISTED AS ADDITIONAL INSURERS
UNDER THE POLICY WITH WAIVER OF SUBROGATION. CONTRACTOR SHALL FURNISH OWNER WITH A CERTIFICATE OF INSURANCE WITH A 30 DAY NOTICE OF CANCELLATION. OWNER SHALL OBTAIN A BUILDER'S RISK POLICY WITH
ARCHITECT NAMED AS AN ADDITIONAL INSURED WITH WAIVER OF SUBROGATION.
14. SCOPE OF DRAWINGS AND SPECIFICATIONS:
THESE DRAWINGS AND SPECIFICATIONS SHALL BE INTENDED TO SHOW AND DESCRIBE DETAILS FOR A CONSTRUCTIBLE BUILDING. PARTS AND DETAILS NOT FULLY SHOWN OR DESCRIBED SHALL BE DETAILED AND EXECUTED ACCORDING
TO STANDARD FIRST CLASS PRACTICE AND IN SIMILAR MANNER AND SPIRIT OF THE DETAILS WHICH ARE SHOWN ON THE DRAWINGS AND/OR DESCRIBED IN THE PROJECT MANUAL. IF CONTRACTOR OR SUB-CONTRACTOR FINDS ANY
DETAILS WHICH, IN HIS OPINION, ARE UNSOUND, UNSAFE, OR NOT WATERPROOF, IT IS HIS DUTY TO NOTIFY ARCHITECT IN WRITING OF THIS FACT. IF WORK IS PERFORMED AS DETAILED, IT WILL BE ASSUMED THAT THERE ARE NO
OBJECTIONS TO THE DETAIL. ACCURACY OF ALL DIMENSIONS SHALL BE CHECKED. NO EXTRA COMPENSATION WILL BE ALLOWED FOR DIFFERENCE BETWEEN ACTUAL DIMENSIONS AND THOSE INDICATED ON THE DRAWINGS.
IN USING THESE PLAN FOR BIDDING OR CONSTRUCTION PURPOSES, ALL CONTRACTORS ARE REQUIRED TO REVIEW AND TREAT THEM AS A WHOLE IN ORDER TO IDENTIFY ALL REQUIREMENTS THAT DIRECTLY OR INDIRECTLY AFFECT THEIR
PORTION OF THE WORK, EVEN REQUIREMENTS LOCATED IN SECTIONS DESIGNATED AS APPLICALBE TO OTHER TRADES. IN CAS OF CONFLICTS, THE AFFECTED CONTRACTOR IS REQUIRED TO EITHER OBTAIN DIRECTION FROM AN
APPROPRIATE REPRESENTATIVE OF THE OWNER, OR OTHERWISE TO APPLY THE MORE STRINGENT STANDARD.
THESE PLANS ARE INTENDED TO SET FORTH THE REQUIREMENTS FOR CONSTRUCTION IN ONLY AN INDUSTRY-STANDARD LEVEL OF QUALITY AND DETAIL, AND THE ARE INTENDED TO BE SUPPLEMENTED BY APPROPRIATE REQUESTS FOR
CLARIFICATION AND INFORMATION. ERRORS AND OMISSIONS ARE TO BE EXPECTED AND ANTICIPATED, AND ALL CONTRACTORS ARE REQUIRED TO CAREFULLY REVIEW THESE PLANS FOR ERRORS AND OMISSIONS AND TO BRING THESE
ERRORS AND OMMISIONS TO THE ATTENTION OF A APPROPRIATE OWNER & ARCHITECT IN WRITING IN A TIMELY MANNER; AND ANY CONTRACTOR WHO FAILS TO DO SO BEFORE BIDDING OR OTHERWISE PROCEEDING ASSUMES THE RISK
OF ANY CONSEQUENCES. SCALED DIMENSIONS SHOULD BE CONSIDERED ONLY APPROXIMATE; AND IN ANY DIMENSIONS BEFORE PROCEEDING WITH ANY AFFECTED PROCUREMENT, FABRICATION OR CONSTRUCTION. SCHEMATIC PLANS
ARE INTENDED ONLY TO DEMONSTRATE THE RELATIONSHIP AMONG COMPONENT PARTS, AND NOT TO DEPICT SPECIFIC LOCATIONS (e.g. SCHEMATIC ELECTRICAL PLANS).
15. DIMENSIONS ON DRAWINGS:
FIGURED DIMENSIONS SHALL BE FOLLOWED IN PREFERENCE TO SCALE, AND DETAIL DRAWINGS IN PREFERENCE TO SMALL SCALE DRAWINGS. SUB-CONTRACTOR AND CONTRACTOR SHALL CHECK ACCURACY OF ALL DIMENSIONS IN THE
FIELD PRIOR TO ANY WORK BEING CONSTRUCTED OR MATERIALS OR PRODUCTS FABRICATED OR ORDERED. SPECIFICATIONS AND WRITTEN NOTES AND SCHEDULES ON DRAWINGS SHALL BE FOLLOWED IN PREFERENCE TO INFORMATION
FURNISHED IN THE FORM OF LINE DRAWINGS. DETAILED DRAWINGS FURNISHED DURING CONSTRUCTION OR APPROVED BY CONTRACTOR OR ARCHITECT ARE TO BE CONSIDERED EXPLANATORY AND NOT AS CHANGES TO DRAWINGS AND
SPECIFICATIONS. NOTES, FIGURES AND DETAILS ON SAID DRAWINGS SHALL BE FOLLOWED AND EXECUTED AS IF PART OF THESE DOCUMENTS.
DRAWINGS ARE NOT TO BE SCALED UNLUESS PERMITTED BY THE ARCHITECT. DIMENSIONS SHALL GOVERN. ALL EXTERIOR DIMENSIONS ARE BASED ON NOMINAL SIZES OF MEMBERS AND ARE GIVEN TO THE OUTER FACE OF SUCH
MEMBERS, UNLESS OTHERWISE NOTED ON DRAWINGS. INTERIOR PARTITIONS ARE DIMENSIONED FROM FACE OF STRUCTURE TO FACE OF STRUCTURE UNLESS OTHERWISE NOTED ON DRAWINGS. WHERE DIMENSION IS LABELED "CLEAR"
IT IS TAKEN FROM THE FACE OF FINISH TO FACE OF FINISH OF EACH MATERIAL. PLUS OR MINUS (+/-) DIMENSIONS SHALL NOT VARY BY MORE THAN 2" WITHOUT APPROVAL BY ARCHITECT. WALL ANGLES ARE EITHER 90° OR 45° UNLESS
NOTED OTHERWISE.
16. SUBMITTALS, MEETING NOTES, BULLETINS, AND MEMOS:
SUBMITTALS WILL BE REVIEWED BY THE ARCHITECT, IF AT ALL, ONLY PURSUANT TO THE INDUSTRY-STANDARD PROTOCOL SET FORTH IN AIA DOCUMENT A201-1997; AND IN NO EVENT WILL THE SUBMITTAL REVIEW PROCESS RELIEVE OR
LESSEN THE SUBMITTING CONTRACTOR'S RESPONSIBILITY FOR AN INAPPROPRIATE SUBMITTAL.
ARCHITECT, FROM TIME TO TIME, WILL ISSUE CONSTRUCTION NOTES OR MEMOS REGARDING CONSTRUCTION ISSUES THAT HAVE ARISEN SINCE THE DRAWINGS AND SPECIFICATIONS WERE COMPLETED. CONTRACTOR SHALL REVIEW
THESE WRITTEN DOCUMENTS AND INCORPORATE THEM INTO THE PROJECT. ANY QUESTIONS OR OBJECTIONS AS TO THE INTENT OF THE WRITTEN DOCUMENT ITEMS WILL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT
FOR DISCUSSION AND OR CLARIFICATION. ANY ITEM THAT RESULTS IN A CHANGE TO THE COST OR TIMING OF THE PROJECT SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE OWNER & ARCHITECT PRIOR TO EXECUTING.
CONTRACTOR SHALL SUBMIT FABRICATION SHOP DRAWINGS TO THE ARCHITECT FOR APPROVAL PRIOR TO ORDERING AND/OR FABRICATION. CONTRACTOR SHALL SUBMIT MANUFACTURER'S CUTS FOR ALL FIXTURES AND EQUIPMENT
CALLED FOR ON THE CONSTRUCTION DOCUMENTS TO ARCHITECT INCLUDING BUT NOT LIMITED TO LIGHT FIXTURES, HARDWARE, PLUMBING FIXTURES, KITCHEN EQUIPMENT, ETC. BY SUBMITTING SHOP DRAWINGS AND PRODUCT DATA,
THE CONTRACTOR REPRESENTS THAT HE/SHE HAS VERIFIED FIELD CONDITIONS, DIMENSIONS AND RELATED CONSTRUCTION AND HAS COORDINATED THE SUBMISSION CONSTUCTION WITH THE REQUIREMENTS OF ALL OTHER RELATED
WORK IN THE CONSTRUCTION DOCUMENTS.
ALL SHOP DRAWINGS AND CUTS MARKED "REVIEWED" BY ARCHITECT, ARE FOR VERIFCATION OF ADHERENCE TO THE DESIGN INTENT ONLY. THE CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR ALL MEANS AND METHODS AND ERRORS
AND OMISSIONS ON THEIR DRAWINGS. CONTRACTOR TO SUBMIT A COMPLETE SHOP DRAWINGS AND OR SUBMITTAL FOR APPROVAL BEFORE COMMENCING FABRICATION AND/OR INSTALLATION OF ALL APPLICABLE ITEMS. ALL SHOP
DRAWINGS DIMENSIONS SHALL BE FIELD VERIFIED, REVIEWED AND APPROVED BY CONTRACTOR BEFORE SUBMITTAL. SHOP DRAWINGS WHICH ARE INCOMPLETE OR LACKING SUFFICIENT INFORMATION WILL BE RETURNED WITHOUT
REVIEW.
SUBMIT SAMPLES FOR INITIAL SELECTION PURPOSES OF ACTUAL VENEERS SHOWING A FULL RANGE OR GRAIN VARIATION, FINISH AND PATTERNS PROPOSED. SUBMIT SAMPLES AS REQUIRED UNTIL APPROVED BY ARCHITECT. SAMPLES
SHALL BE 12" X 12" MIN., ONE UNIT OF EACH TYPE AND FINISH.
17. ERRORS AND OMISSIONS:
ERRORS OR OMISSIONS WHICH APPEAR ON THE DRAWINGS, IN SPECIFICATIONS OR OTHER CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT BY THE CONTRACTOR AND TO THE CONTRACTOR
BY THE SUB-CONTRACTOR IN WRITING. IN EVENT OF FAILURE OF SUB-CONTRACTOR TO GIVE SUCH WRITTEN NOTIFICATION BEFORE CONSTRUCTION OR FABRICATIONS OF THE WORK, HE WILL BE HELD RESPONSIBLE FOR THE RESULTS OF
ANY SUCH ERRORS OR OMISSIONS AND THE COSTS OF RECTIFYING SAME. HOWEVER, DRAWINGS AND SPECIFICATIONS ARE COMPLEMENTARY AND WORK CALLED FOR ON ONE AND NOT THE OTHER SHALL BE PROVIDED AS THOUGH FULLY
SET FORTH IN BOTH.
18. BARRICADES:
CONTRACTOR SHALL ERECT AND PROPERLY MAINTAIN AT ALL TIMES AS REQUIRED BY CONDITIONS AND PROGRESS OF THE WORK, ALL NECESSARY PROTECTIVE BARRICADES, FENCES AND OTHER SAFEGUARDS FOR THE PROTECTION OF
THE WORKERS AND THE PUBLIC. THESE BARRICADES SHALL BE CONSTRUCTED AND BE LOCATED AS SHALL BE DETERMINED BY LOCAL AUTHORITIES AND CODES.
19. TEMPORARY BRACING:
AT ALL TIMES DURING CONSTRUCTION ACTIVITIES OR ERECTION OF PROJECT OR ITS COMPONENT PARTS, PRIOR TO COMPLETION OF THE STRUCTURAL FRAME OR REPLACEMENT AND PERMANENT CONNECTION OF COMPONENT MEMBERS
TO THE STRUCTURAL FRAME, SUB-CONTRACTORS SHALL PROVIDE, INSTALL AND MAINTAIN PROPERLY DESIGNED AND CONSTRUCTED TEMPORARY BRACING OF ADEQUATE STRENGTH TO PREVENT DISLOCATION, DISTORTION, CRACKING,
FALLING OFF, OR ANY OTHER DAMAGE TO WORK OR ANY OF ITS COMPONENT PARTS DUE TO FORESEEABLE NORMAL AS WELL AS NOT FORESEEABLE EXCESSIVE WIND AND EARTHQUAKE FORCES WITHOUT ADDITIONAL COST TO OWNER.
CONTRACTOR AND HIS SUB-CONTRACTORS SHALL, AT THEIR EXPENSE, REPLACE OR REPAIR, AS DIRECTED, DAMAGED PORTIONS OF THEIR WORK OR COMPONENT PARTS.
20. TOXIC SUBSTANCES REMOVAL:
PRIOR TO ANY WORK BEING PERFORMED, WHENEVER THERE ARE EXISTING STRUCTURES TO BE REMOVED OR ALTERED, CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION AND REMOVAL OF ANY TOXIC MATERIALS OR
SUBSTANCES AS REQUIRED BY THE STATE OF CALIFORNIA INCLUDING BUT NOT LIMITED TO ASBESTOS, LEAD PAINTS, MOLD, ETC. REMOVAL AND DISPOSAL SHALL FOLLOW STATE MANDATED METHODS, PROCEDURES, DOCUMENTATION
AND APPLICATION REQUIREMENTS.
21. NO CHANGES ARE TO BE MADE ON THESE PLANS WITHOUT THE KNOWLEDGE OR CONSENT OF THE ARCHITECT/ ENGINEER WHOSE SIGNATURE APPEARS HERON.
22. NO FRAMING OF ANY TYPE TO BE CONCEALED PRIOR TO INSPECTION BY GOVERNING AGENCIES.
23. REFERENCES TO ANY DETAIL OR DRAWINGS IS FOR CONVENIENCE ONLY AND DOES NOT LIMIT THE APPLICATION OF SUCH DETAIL OR DRAWINGS.
24. USE 2x6 MINIMUM STUDS FOR PLUMBING WALLS
25. MAXIMUM FLOW RATE STANDARDS SET BY THE CURRENT CALIFORNIA GREEN CODE - G.C. TO VERIFY PRIOR TO PURCHASE AND INSTAL. OF ANY FIXTURES.
26. EXTERIOR DECKS, BALCONIES, AND STAIRWAYS SEALED UNDERNEATH SHALL BE WATERPROOFED- ARCH. TO APPV. METHOD OF WATERPROOFING - G.C. TO SUBMIT SPECIFICATIONS.
27. SPECIAL INSPECTION IS REQUIRED FOR THE FOLLOWING:
* FOUNDATION INSPECTION BY SOILS ENGINEER PRIOR TO CONCRETE POUR AND:
* PER SOILS REPORT: OVER EXCAVATION, RECOMPACTION, FOOTING DEPTH, UTILITY TRENCH BACK FILL
* RETAINING WALL BACK FILL, PRE SATURATION OF SLAB AREAS, EXTERIOR FLAT WORK AREAS.
* ALL TO BE ADDRESSED IN A REPORT PRESENTED TO BUILDING DEPT. PRIOR TO FINAL
* ALL FIELD WELDING OF STRUCTURAL STEEL
* INSTALLATION OF ALL HIGH STRENGTH BOLTS
* CERTIFICATION OF WELD, & BOLTING TO BE GIVEN TO BUILDING DEPARTMENT PRIOR TO FRAMING INSPECTION.
28. MAX. TEMP. OF 120° TO BE APPROVED BY THE USE OF PRESSURE BALANCE OR THERMOSTATIC MIXING VALVES TYP. @ SHOWERS & TUBS.
29. MAINTENANCE INFORMATION:
THE BUILDER SHALL PROVIDE TO THE BUILDING OWNER AT OCCUPANCY MAINTENANCE INFORMATION FOR ALL FEATURES, MATERIALS, COMPONENTS, AND MANUFACTURED INFORMATION FOR ALL FEATURES, MATERIALS, COMPONENTS
AND MANUFACTURED DEVICES THAT REQUIRE ROUTINE MAINTENANCE FOR EFFICIENT OPERATION. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY STATED AND INCORPORATED ON A READILY ACCESSIBLE LABEL. THE
LABEL MAY BE LIMITED TO IDENTIFYING, BY TITLE AND/OR PUBLICATION NUMBER, THE OPERATION AND MAINTENANCE MANUAL FOR THAT PARTICULAR MODEL AND TYPE OF FEATURE, MATERIAL, COMPONENT, OR MANUFACTURED DEVICE.
30. AFTER INSTALLING WALL, CEILING, OR FLOOR INSULATION, THE INSTALLER SHALL MAKE AVAILABLE TO THE ENFORCEMENT AGENCY OR POST IN A CONSPICUOUS LOCATION IN THE BUILDING A CERTIFICATE SIGNED BY THE INSTALLER
STATING THAT THE INSTALLATION IS CONSISTENT WITH THE PLANS AND SPECIFICATIONS FOR WHICH THE BUILDING PERMIT WAS ISSUED. THE CERTIFICATE SHALL ALSO STATE THE MANUFACTURER'S NAME AND MATERIAL IDENTIFICATION,
THE INSTALLED R-VALUE, AND (IN APPLICATIONS OF LOOSE FILL INSULATION) THE MINIMUM INSTALLED WEIGHT PER SQUARE FOOT CONSISTENT WITH THE MANUFACTURER'S LABELED INSTALLED DESIGN DENSITY FOR THE DESIRED R-
VALUE.
31. ON PROJECTS WITH EXCAVATIONS THAT WILL BE LOWER THAN ADJOINING PROPERTIES, 30 DAY NOTICE IS LEGALLY REQUIRED BY THE OWNERS & CONTRACTORS TO THE ADJOINING PROPERTY OWNERS OUTSIDE THE SETBACK AREA.
32. DISTANCE FROM THE FACE OF FOUNDATION TO PROPERTY LINE TO BE ZONING SETBACK PLUS WALL FINISH THICKNESS.
33. ROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR FIXTURES SHALL BE PROVIDED WITH ON EXHAUST FAN WITH A MINIMUM CAPACITY OF 50 CFM. DUCTLESS FANS ARE UNACCEPTABLE. CBC 1203.4.3.2.1, CMC T-4-4
34. SAFETY GLAZING SHALL BE PROVIDED AT THE FOLLOWING HAZARDOUS LOCATIONS: CBC 2406.3
A. SWINGING AND SLIDING DOORS
B. WHEN LOCATED WITHIN 60- INCHES OF THE FLOOR SURFACE IN TUBS, SHOWERS, SUANAS, OR STEAM ROOMS.
C. WITHIN A 24-INCH ARC OF EITHER VERTICAL EDGE OF DOORS AND WITHIN 60-INCHES OF WALKING SURFACE.
D. WHERE GLAZING AREA IS MORE THAN 9 SQ. FT. IN AREA, WITH A BOTTOM EDGE LESS THAN 18-INCHES ABOVE THE FLOOR AND TOP EDGE MORE THAN 36-INCHES ABOVE FLOOR.
E. ADJACENT TO STAIRWAYS, LANDINGS AND RAMPS WITHIN 36-INCHES HORIZONTALLY OF WALKING SURFACE AND WITHIN 60-INCHES ABOVE WALKING SURCFACE.
F. ADJACENT TO STAIRWAYS WITHIN 60-INCHES HORIZONTALLY OF BOTTOM TREAD OF STAIRWAY AND EXPOSED SURFACE IS WITHIN 60-INCH ABOVE NOSE OF TREAD.
35. CLEARANCE FOR WATER CLOSET TO BE A MINIMUM OF 24-INCHES IN FRONT AND 15-INCHES FROM ITS CENTER TO ANY SIDE WALL OR OBSTRUCTION. CPC 407.5
36. THE NET AREA OF THE SHOWER ENCLOSURE SHALL BE 1,024 SQ. INCHES (7.1 SQ. FT.) OR MORE IN THE CLEAR FLOOR AREA, AND SHALL ALSO BE CAPABLE OF ENCOMPASSING A 30-INCH DIAMETER CIRCLE. CPC 411.7
37. WALL COVERINGS OR SHOWERS OR TUBS WITH SHOWERS SHALL BE OF CEMENT PLASTER, TILE, OR APPROVED EQUAL, TO A HEIGHT OF NOT LESS THAN 70-INCHES ABOVE DRAIN INLET. PROVIDE CEMENT BOARD OR CEMENT PLASTER
BACKING FOR TILE. CBC 1210.3
38. MIN. 5/8" TYPE 'X' MOISTURE RESISTANT GYPSUM WALL BOARD IN ALL BATHROOMS AND KITCHENS
39. EXTERIOR LATH AND PLASTER: PROVIDE TWO LAYERS OF GRADE D PAPER OVER ALL WOOD BASE SHEATHING. CBC 2510.6
40. THE WATER HEATER BURNER TO BE AT LEAST 18-INCHES ABOVE THE GARAGE FLOOR, IF LOCATED IN A GARAGE. CPC 508.14
41. PROVIDE A 3-INCH DIAMETER BY 3-FOOT TALL STEEL PIPE EMBEDDED IN CONCRETE SLAB FOR PROTECTION OF WATER HEATERS IN GARAGE. CPC 508.14
42. WATER HEATERS TO BE STRAPPED AT TOP AND BOTTOM WITH 1-1/2" X 16 GAUGE STRAP WITH 3/8" DIA. X 3" LAG BOLT EACH IND. CPC 508.2
43. DRYER:
THE CLOTHES DRYERS VENT SHALL NOT EXCEED 14-FEET IN OVERALL LENGTH. CMC 504.3.2 DRYER VENT TERMINATION MUST BE 3 FT. CLEAR FROM OPENINGS INTO THE BUILDING ( DOORS AND OPERABLE WINDOWS) . CMC 504.5
PROVIDE A MIN. 100 SQ.IN. OPENING IN THE DRYER DOOR. CMC. 504.3.2
44. SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS (R314.3):
A. IN EACH SLEEPING ROOM.
B. OUTSIDE EACH SEPERATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS
C. ON EVERY LEVEL OF DWELLING, INCLUDING BASEMENTS AND HABITABLE ATTICS.
SMOKE ALARMS SHALL BE HARDWIRED WITH BATTERY BACK-UP AND INTERCONNECTED UNLESS EXEMPTED IN ACCORDANCE WITH SECTIONS R314.4 & R314.5
45. CARBON MONOXIDE ALARMS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS (R315.3):
A. OUTSIDE OF EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOM(S)
B. ON EVERY LEVEL OF THE DWELLING UNIT INCLUDING BASEMENTS.
CARBON MONOXIDE ALARMS SHALL BE HARDWIRED WITH BATTERY BACK-UP AND INTERCONNECTED UNLESS EXEMPTED IN ACCORDANCE WITH SECTIONS R314.4 & R314.5
46. ALL RECEPTACLE OUTLETS IN BATHROOMS, ABOVE KITCHEN COUNTERTOP, CRAWL SPACES, GARAGE, ROOFTOPS, OUTDOOR OUTLETS, WITHIN 6-FEET OF WET BAR SINK/LAUNDRY SINK TO BE PROTECTED BY GROUND FAULT CIRCUIT
INTERRUPTER (GFCI) CEC 210.8
47. ALL 120V SINGLE PHASE, 15 AND 20 AMP OUTLETS (RECEPTACLES, LIGHTING, SMOKE DETECTORS, ETC.) TO BE PROTECTED BY COMBINATION TYPE ARC-FAULT CIRCUIT INTERRUPTER (AFCI) CEC 210.12
48. ELECTRICAL SERVICE TO BE UNDERGROUND FOR NEW CONSTRUCTION OR ADDITIONS >50%. NBMC 12.32.015
49. INSPECTOR TO REVIEW AND APPROVE UNDERGROUND ELEC. SERVICE PRIOR TO CONCRETE PLACEMENT.
50. UTILITY COMPANY APPROVAL IS REQUIRED FOR METER LOCATION PRIOR TO INSTALLATION.
51. FACTORY-BUILT FIREPLACES, CHIMNEYS, AND ALL OTHER COMPONENTS SHALL BE LISTED AND LABELED AND SHALL BE INSTALLED IN ACCORDANCE WITH THE CONDITIONS OF THE LISTING
52. FIREPLACE:
DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT THE TERMINATION OF FACTORY-BUILT CHIMNEY SYSTEMS AND ARE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS R1005.4NG. CMC (802.5.2.4)
PROVIDE A PERMANENTLY ANCHORED GASEOUS FUEL BURNING PAN TO THE FIREBOX IN A SOLD FUEL BURNING FIREPLACE. SOLID FUEL BRUNING FIREPLACE MUST COMPLY WITH THE CALIFORNIA ENERGY STANDARDS MANDATORY
MEASURES." GAS APPLIANCE FIREPLACE MUST COMPLY WITH THE CALGREEN CODE REQUIRMENTS."
53. ALL DOORS FROM THE HOUSE INTO THE POOL AREA SHALL BE EQUIPPED WITH AN APPROVED ALARM OR AN APPROVED ALTERNATE DROWNING PREVENTION SAFETY FEATURE. CBC 3109.4.4.2
54. GENERAL CONTRACTOR, CONTRACTORS, SUB-CONTRACTORS AND BUILDERS TO COORDINATE ALL ENGINEERING AND MECHANICAL DRAWINGS WITH ARCHITECTURAL DRAWINGS BEFORE PROCEEDING WITH WORK. IF DISCREPANCIES
ARE APPARENTLY OBSERVED OR INFORMATION APPARENTLY IS THOUGHT TO BE MISSING, NOTIFY ARCHITECT WITHIN 24 HOURS WITH SKETCH, DRAWING, PDF, PHOTOCOPIES WITH LEGIBLE HAND WRITTEN NOTES AND/OR WRITING (FAX,
EMAIL OR CORRESPONDENCE). IF CONFLICT WITH EXISTING CONDITIONS, PROVIDE DOCUMENTATION (PHOTOS, SKETCHES, DWGS) OF EXISTING CONDITIONS AND SUGGEST PROPOSAL(S) FOR SOLUTION (SKETCH, DRAWING, AND/OR
WRITING). IN CASE OF ANY DISCREPANCIES, THE ARCHITECT IS THE SOLE INTERPRETER OF THE CONTRACT DOCUMENTS.
55. ISSUANCE OF A BUILDING PERMIT DOES NOT RELIEVE APPLICANTS OF THE LEGAL REQUIREMENTS TO OBSERVE COVENANTS, CONDITIONS AND RESTRICTIONS WHICH MAY BE RECORDED AGAINST THE PROPERTY OR TO OBTAIN PLANS.
YOU SHOULD CONTACT YOUR COMMUNITY ASSOCIATIONS PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION AUTHORIZED BY THIS PERMIT.
56. LAND. WALLS LOCATED IN FRONT AND BACK OF PROPERTY SHALL NOT EXCEED 42" HT. REFER. LAND. DWGS FOR LOC'T.
57. LAND. WALLS LOCATED BTW. NEIGHBORS SHALL BE SHARED ON PROP. LINE. REFER. LAND. DWGS AND SEE ATTACHED DOCUMENT FOR "AGRREMENT TO BUILD A FENCE OR WALL CENTERED OVER THE PROPERTY WALL."
58. ALL INTERIOR AND EXTERIOR JOINTS BETWEEN DIFFERENT MATERIALS OR FINISHES SHALL RECEIVE A BEAD OF CAULKING OR SEALANT TO FORM A REVEAL TO MATCH COLOR OF ADJACENT SURFACE. COORDINATE COLORS WITH
ARCHITECT.
59. CONTRACTOR SHALL NOTIFY ARCHITECT FOR CLARIFICATION PRIOR TO BIDDING OF ANY DISCREPANCIES BETWEEN ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS. BID SHALL BE BASED ON THE MOST STRINGENT
REQUIREMENT.
60. CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT OF ANY UNEXPECTED OR UNKNOWN FIELD CONDITIONS, ERRORS, OMISSIONS, OR DISCREPANCIES IN THE DRAWINGS, PROJECT MANUAL, OR CONTRACT DOCUMENTS PRIOR
TO PROCEEDING WITH THE WORK OR SHOP FABRICATIONS.
HEATING VENTILATING/AIR COND.
DRINKING FOUNTAIN/DOUGLASS FIRD.F.
EA.
E.P.
ENCL.
EMER.
ELEV.
ELEC.
EL.
E.J.E.
DWG.
D.S.P.
D.S.
DR.
DN.
DIM.
DIAG.
DIA.
EACH
EXPANSION JOINT
ELEVATION
ELEVATOR
EMERGENCY
ENCLOSURE
ELECTRIC PANEL
ELECTRIC
DIAMETER
DIAGONAL
DIMENSION
DOWN SPOUT
DRY STAND PIPE
EAST, ENTRY
DOWN
DOOR
DRAWING
DET.
DEPT.
DBL.
CTR.
CTSK.
CORR.
CONT.
CONST.
COND.
CONC.
CNTR.
CLR.
CLKG.
CLG.
C.J.
C.I.
CHG.
CHAN.
C.G.
CEM.
C.B.
CAB.
CONCRETE
CONDITION
CONSTRUCTION
CONTRACTOR/ CONTINUOUS
CORRIDOR, CORROSIVE
COUNTERSUNK
DEPARTMENT
COUNTER
CENTER
DOUBLE
DETAIL
CATCH BASIN
CORNER GUARD
CAST IRON
CONTROL JOINT/ CONST. JOINT
CAULKING
CABINET
CEMENT
CHANNEL
CHANGE
CEILING
CLEAR
LOAD FROM ABOVE
JANITOR
KITCHEN
LANDSCAPED AREA
LABORATORY
LAMINATE
LAVATORY
POUNDS
LEFT HAND
LOCKER
LUMINOUS
MAINTENANCE
MASONRY
LBS.
LFA
MAS.
MAINT.
LUM.
LT.
LKR.
L.H.
LIGHT
LAV.
LAM.
LAB.
L.A.
L.
KIT.
JST.
JT.
JAN.
JOINT
JOIST
LOW/LINEN
HOSE BIB
HOLLOW CORE
HARDWOOD
HARDWARE
HEIGHT
HOLLOW METAL
GALVANIZED IRON
GLU-LAM BEAM
GROUND
GYPSUM
HORIZONTAL
INSULATION
INTERIOR
INVERT/INVERTED
INSIDE DIAMETER/INTERIOR DESIGNER
HDWR.
I.D.
HVAC
INV.
INT.
INSUL.
IN.
HR.
HORIZ.
H.M.
HT./HGT.
HOUR
INCH
GYP.
GR.
GND.
G.L.B.
GL.
G.I.
HDWD.
HD.
H.C.
H.B.
H.HIGH
HARD
GLASS
GRADE
AREA DRAINA.D.
B.W.
BR.
B.
BOT.
BM.
BLK'G.
BLK.
BLDG.
BITUM.
BET.
BD.
AUTO.
ASSY.
ASB.
ARCH.
APPX.
A.P.
ANOD.
ALT.
AL.
ADJ.
ADH.
BITUMINOUS
BLOCKING
BATH
BEDROOM
BACK OF WALK, BOT. OF WALL
BOARD
BETWEEN
BUILDING
BLOCK
BEAM
BOTTOM
ADHESIVE
ADJUSTABLE
ALUMINUM
ALTERNATE
ANODIZED
ACCESS PANEL
APPROXIMATELY
ARCHITECTURAL
ASBESTOS
ASSEMBLY
AUTOMATIC
PL
LC
ACOUS.
A.C.
A/C
A.B.
#
∅
@
&
ANGLE
CENTERLINE
DIAMETER OR ROUND
PERPENDICULAR
POUND OR NUMBER
PROPERTY LINE, PLATE
ANCHOR BOLT
AIR CONDITIONING
ASPHALT CONCRETE
ACOUSTICAL
AT
AND
FINISH GRADE
FLAT HEAD
FIXTURE
FLOW LINE
FLASHING
FLUORESCENT
FACE OF CONCRETE/FACE OF CURB
FACE OF FINISH
FACE OF STUD/FACE OF STRUCTURE
FACE OF MASONRY
FIREPLACE
FLOOR SINK
FOOT OR FEET
FOOTING
FURRING
FUTURE
GALVANIZED
GRAB BAR/GRADE BEAM
GENERAL
GROUND FAULT INTERRUPTG.F.I.
GEN.
G.B.
GALV.
GA.
FUT.
FURR.
FTG.
FT.
F.S.
FP.
GAUGE
F.O.M.
F.O.S.
F.O.F.
F.O.C.
FLUOR.
FLR.
FLASH.
F.L.
FIX./FIXT.
FIN.
F.H.
F.G.
FINISH
FLOOR
EQUIPMENT
EXISTING
EXHAUST
EXPOSED
EXTERIOR
FIRE ALARM
FLOOR CLEAN OUT
FLOOR DRAIN
FOUNDATION
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
EQPT./EQPM.
F.E.C.
F.E.
FDN.
F.D.
F.C.O.
F.A.
F.
EXT.
EXPO.
EXH.
EXST.
FIXED
SOUTHS.
SUPPLY AIR
SOLID CORE
SCHEDULE
SECTION
SHELF
SHEET
SHEATHING
SIMILAR
SOFFIT JOIST
SERVICE SINK
STATION
STANDARD
STEEL
STORAGE
STRUCTURAL
SUSPENDED
SYMMETRICAL
STAINLESS STEEL
SEAT COVER DISPENSER
SUB DRAIN/SOAP DISPENSER
S.S.
SUSP.
STRUCT.
STOR.
SYM.
STL.
STD.
STA.
S.SK.
S.C.D.
SHT'G.
SCHED.
S.D.
S.J.
SIM.
SHT.
SH.
SEC.
S.C.
S.A.
PLUMBING
PLYWOOD
POINT OF CONNECTION
PROJECTION
POINT
RETURN AIR
RADIUS
ROOF DRAIN
RECEPTACLE
RECTANGULAR
REFERENCE
REFRIGERATOR
ROOF DRAIN LEADER
REGISTER
REQUIRED
RESILIENT'
ROOM
REDWOOD
REINFORCEMENT
ROUGH OPENING
RETAIN(ING), RETURN
RECT.
REINF.
RESIL.
REQ'D.
REFR./ R/F.
RET.
R.O.
RWD.
RM.
REG.
REF.
R.D.L.
RECPT.
PROJ.
PLYWD.
PLUMB.
R.D.
RAD.
R.A.
PT.
PR.
PNT.
PAIR
MOUNTEDMTD.
MULLION
NORTH
NATURAL
NUMBER
NOMINAL
NOT TO SCALE
OVER
OVERALL
OBSCURE
OFFICE
OPENING
OPPOSITE
PERIMETER
PLATE/PROPERTY LINE
PLASTER
NOT IN CONTRACT
NATURAL GRADE
OVERFLOW DRAIN
PLASTIC LAMINATE
OUTSIDE DIAMETER (DIMENSION)
O/.
P.LAM.
O.F.D.
PERIM.
OPNG.
O.D.
PLAS.
PL.
OPP.
OFF.
OBS.
O.A.
N.G.
N.I.C.
N.T.S.
NOM.
NO.
NAT.
N.
MUL.
MATERIAL
MAXIMUM
MECHANICAL
MEMBRANE
METAL
MAN HOLE
MINIMUM
MIRROR
MOSAIC
MEDICINE CABINET
MANUFACTURER
MISCELLANEOUS
MASONRY OPENING
MAX.
MEMB.
MECH.
M.O.
MISC.
MFR./MFGR.
M.C.
MOS.
MIR.
MIN.
M.H.
MET./MTL.
MAT.
TYPICALTYP.
UNIFORM BULIDING CODE
UNDERWRITER'S LABORATORY
UNLESS NOTED OTHERWISE
VENT THROUGH ROOF
WEST, WIDE, WIDTH
V.T.R.
WP.
W.I.
W.C.
W.H.
W.
WD.
W/.WITH
WOOD
WATER HEATER
WATER CLOSET
WROUGHT IRON
WATERPROOF
U.N.O.
U.L.
U.B.C.
VERT.
VENT.
UR.
UNF.
U.UNDER
UNFINISHED
URINAL
VENTILATING
VERTICAL
TOP OF PAVING
TOP OF STRUCTURE/SLAB
TONGUE AND GROOVE
TOP OF CURBT.C.
T.&G.
T.W.
T.O.S.
T.PL.
T.P.
TER.
TEMP.
TEL.
T.CL.
TRANS.
THK.THICK
TRANSFORMER
TIME CLOCK
TELEPHONE
TEMPERED
TERRAZZO
TOP OF PLATE
TOP OF WALL
T.TREAD
PAINT(ED)
P.O.C.
EQ.EQUAL / EQUIVALENT
FIELD VERIFYF.V.
(E.)EXISTING
NEW(N.)
VER.VERIFY
FACTORYFAC.
B.O.BY OWNER/BY OTHERS
GENERAL CONTRACTORG.C.
APPV'D.APPROVED
BEL.BELOW
ON CENTERO.C.
ABV.ABOVE
HDR.HEADER
SELECTEDSEL.
METAL BOLTM.B.
PARALLEL STRAND LAMINATEPSL.
ROOF RAFTERR.R.
/CEILING JOIST
FLOOR JOISTF.J.
SIMPSONSIMP.
T.S.TOP OF STEP
UNDERGROUNDU.G.
V.VERTICAL
W.W.M.WELDED WIRE MESH
EACH WAYE.W.
DECO.DECORATIVE
EXISTING GRADEE.G.
GRADE PLANEG.P.
61. CONTRACTOR SHALL PREPARE AND MAINTAIN ALL CONSTRUCTION, AND SURROUNDING AREAS, FREE OF DEBRIS OR HAZARDOUS MATERIALS AT ALL TIMES. CONTRACTOR SHALL TAKE
NECESSARY PRECAUTIONS TO PREVENT DUST FROM RISING.
62. CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR AND/OR THE REPLACEMENT OF ANY ITEMS DAMAGED DURING CONSTRUCTION OR CLEAN-UP. ANY DAMAGE TO EXISTING
STRUCTURES DURING THE CONSTRUCTION OR THE NEW WORK SHALL BE REPAIRED TO EQUIVALENT OR BETTER THAN ORIGINAL CONDITION AT CONTRACTOR'S EXPENSE.
63. CONSTRUCTION PERSONNEL SHALL BE CONFINED TO THE LIMITS OF THE CONSTRUCTION AREA. ALL OSHA REGULATIONS FOR CONSTRUCTION AREAS SHALL BE STRICTLY FOLLOWED.
CONTRACTOR SHALL PROVIDE PROPER SAFEGUARDS DURING ALL PHASES OF CONSTRUCTION.
64. CONTRACTOR TO REMOVE, RELOCATE OR RE-ROUTE, AS NECESSARY, ELECTRICAL, TELEPHONE, WATER, SEWER, GAS OR ANY OTHER UTILITY LINES ENCOUNTERED AND SHALL
COORDINATE THIS WORK WILL ALL LOCAL UTILITY COMPANIES.
65. CONTRACTOR SHALL PROVDE TEMPORARY WEATHER PROTECTION FOR PORTIONS OF THE WORK THAT BECOME EXPOSED TO WEATHER AND SHALL BE RESPONSIBLE FOR DAMAGE
CAUSED BY INSUFFICIENT PROTECTION.
66. CONTRACTOR TO OBTAIN WRITTEN APPROVAL FROM OWNER AND ARCHITECT PRIOR TO ANY CHANGES OR DEVIATION FROM CONTRACT DOCUMENTS.
67. CONTRACTOR SHALL SUBMIT IN WRITING ALL PROPOSALS FOR ADDITIONAL WORK TO THE OWNER FOR REVIEW AND APPROVAL. NO WORK IS TO PROCEED UNTIL AN AUTHORIZATION TO
PROCEED, SIGNED BY THE ARCHITECT & OWNER'S REPRESENTATIVE IS RETURNED TO THE GENERAL CONTRACTOR.
68. CONTRACTOR SHALL BE AWARE THAT SPECIFIC FIRE-RATED SEPARATION WITHIN THE BUILDING'S CONSTRCUTION ARE REQUIRED BY CODE. THE USE OF SPECIFIC MATERIALS AND
COMBINATION OF MATERIALS WITHIN FIRE RATED ASSEMBLIES, AS CALLED FOR ON THE DRAWINGS AND SPECIFICATIONS, ARE FOR THE PURPOSE OF ACHIEVING THOSE REQUIRED FIRE
SEPARATIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THAT ANY CHANGE IN MATERIAL THAT IS REQUESTED BY OR MADE BY THE CONTRACTOR AND/OR IT'S
SUBCONTRACTORS, FROM THOSE MATERIALS DRAWN OR SPECIFIED, DOES NOT IN ANY WAY AFFECT OR LESSEN THE REQUIRED CONSTRUCTION ASSEMBLY. SPECIFIC SEQUENCES OR
METHODS OF ACHIEVING FIRE RATED ASSEMBLIES REQUIRED BY A "U.L. NO." LISTING SHALL BE FOLLOWED WITHOUT DEVIATION, UNLESS OTHERWISE NOTED OR DETAILED.
69. CONTRACTOR TO FURNISH AND INSTALL ALL BLOCKING REQUIRED FOR WALL MOUNTED OR BRACED FIXTURES, MILLWORK, SHELVES, TOILET FIXTURES, AND ACCESSORIES OR 'BY OTHER'
ITEMS DESCRIBED IN INTERIOR DESIGN AND ARCHITECTURAL DRAWINGS. BLOCKING SHALL BE CONSTRUCTED TO SUPPOR THE IMPOSED LOAD.
70. ALL MANUFACTURED ARTICLES, MATERIALS AND EQUIPMENT SHALL BE SUPPLIED, INSTALLED, CONNECTED, ERECTED, USED, CLEANED AND CONDITIONED AS DIRECTED BY THE
MANUFACTURERS.
71. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY/COORDINATE UTILITY REQUIREMENTS FOR ALL OWNER/VENDOR FURNISHED EQUIPMENT, FIXTURES OR APPLIANCES.
72. CONTRACTOR SHALL PROVIDE ALL NECESSARY FASTENERS, SUPPORTS, SHIMMING, FLASH PATCHING, ETC. FOR THE PROPER INSTALLATION OF SUCH ITEMS AS DIRECTED BY THE
MANUFACTURERS.
73. UPON COMPLETION OF THE PROJECT, THE CONTRACTOR SHALL GIVE TO THE OWNER A COMPLETE SET OF AS-BUILT CIVIL, LANDSCAPE, ARCHITECTURAL, MECHANICAL, PLUMBING
ELECTRICAL AND FIRE PROTECTION DRAWINGS ALONG WITH THE WRITTEN GUARANTIES, OPERATION AND MAINTENANCE MANUALS OF ALL EQUIPMENT AND FINISHES INSTALLED. THE
CONTRACTOR SHALL MAINTAIN A CURRENT SET OF AS-BUILT DRAWINGS AND SPECIFICATIONS. INFORMATION SHALL BE RECORDED BY CONTRACTOR AS CONSTRUCTION PROGRESSES AND
REVIEWED FOR COMPLETENESS AT EACH REQUISITION REQUEST.
74. CONTRACTOR IS RESPONSIBLE TO THOROUGHLY VACUUM CLEAN ALL CARPETED ARES, CLEAN ALL FLOORING, MILLWORK, LIGHT FIXTURES, GLASS, ETC. AND UNCOVER AND VACUUM OUT
ALL MECHANICAL UNITES AFTER THE WORK IS COMPLETED AND MAINTAIN CLEAN CONDITIONS THROUGH THE TENANT'S MOVE-IN.
GENERAL NOTES CONTINUED
NO. REVISION DATE
22
JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT
T-1.2
7/19/19
201837SUPPLEMENTAL NOTES &DOCUMENTSSTUPIN RESIDENCE
STUPIN RESIDENCEAMDREW & JULIE STUPINC/O. COASTLINE REALESTATE INVESTMENTS215TH STREETHUNTINGTON BEACHCA 92648CDP
3322 VIA LIDO, NEWPORT BEACH, CA 92663JUSTIN JONHSTON
CAL GREEN -RESIDENTIAL MANDATORY MEASURES
RESIDENTIAL CONSTRUCTION MINIMUM REQUIREMENTS 2
1
3
NO. REVISION DATE
23
LOT 1TRACT NO. 1622M.M. 47/39PARCEL 1PARCEL 2P.M.B. 2009-125N63°23'21"E 90.00'Δ=04°50'00" R=275.66' L=23.25'N26°36'39"W 18.27'Δ=11°01'06" R=275.66' L=53.01'N63°23'21"E 79.52'N26°36'39"W 52.07'N26°36'39"W 41.50'
VIA LIDO ℄N63°23'21"E 89.02'BASIS OF BEARINGS BENCHMARK INFORMATIONBENCHMARK NO: NB3-18-88DESCRIBED BY OCS 2002 - FOUND 3 3\4" OCS ALUMINUM BENCHMARK DISKSTAMPED "NB3-18-88", SET IN THE TOP OF A CONCRETE BRIDGE ABUTMENT.MONUMENT IS LOCATED IN THE SOUTHWEST CORNER OF THE INTERSECTIONOF WEST LIDO CHANNEL AND VIA LIDO, 19 FT. SOUTHEASTERLY OF THECENTERLINE OF VIA LIDO AND 0.3 MILES SOUTHEASTERLY OF NEWPORTBOULEVARD. MONUMENT IS SET 5 FT. BELOW THE BRIDGE DECK.ELEVATION: 18.418 FEET (NAVD88), YEAR LEVELED 2015VICINITY MAPGRAPHIC SCALELEGAL DESCRIPTION3312 VIA LIDO:REAL PROPERTY IN THE CITY OF NEWPORT BEACH, COUNTY OFORANGE, STATE OF CALIFORNIA, DESCRIBED AS FOLLOWS:LOTS 1 AND 2 IN TRACT 1622, IN THE CITY OF NEWPORT BEACH,COUNTY OF ORANGE, STATE OF CALIFORNIA, AS PER MAP RECORDEDIN BOOK 47, PAGE 39 OF MISCELLANEOUS MAPS, IN THE OFFICE OF THECOUNTY RECORDER OF SAID COUNTY.3324 VIA LIDO:REAL PROPERTY IN THE CITY OF NEWPORT BEACH, COUNTY OFORANGE, STATE OF CALIFORNIA, DESCRIBED AS FOLLOWS:PARCEL 2 OF PM 373-21 OF CONDO PROJECT 933-94 LOCATED ON APN423-123-21.PAUL D. CRAFT, P.L.S. 8516 DATENOTE: SECTION 8770.6 OF THE CALIFORNIA BUSINESS AND PROFESSIONS CODESTATES THAT THE USE OF THE WORD CERTIFY OR CERTIFICATION BY ALICENSED LAND SURVEYOR IN THE PRACTICE OF LAND SURVEYING OR THEPREPARATION OF MAPS, PLATS, REPORTS, DESCRIPTIONS OR OTHER SURVEYINGDOCUMENTS ONLY CONSTITUTES AN EXPRESSION OF PROFESSIONAL OPINIONREGARDING THOSE FACTS OR FINDINGS WHICH ARE THE SUBJECT OF THECERTIFICATION AND DOES NOT CONSTITUTE A WARRANTY OR GUARANTEE,EITHER EXPRESSED OR IMPLIED.LICENSE RENEWAL DATE 12/31/20STATEOFCALI
FORN
IA
PAUL
DOMINICKCRAFTExp. 12/31/20No. 8516PROFES
SI
ONALLANDSURVEYORTITLE REPORT/EASEMENT NOTES3312 & 3324 VIA LIDONEWPORT BEACH, CA 92663(APN: 423-123-12 & 423-123-21 )NO TITLE REPORT PROVIDED.CONCRETE SURFACE1 1TOPOGRAPHIC MAP
3312 VIA LIDO & 3324 VIA LIDO
NEWPORT BEACH, CA 92663
APN: 423-123-12 & 423-123-21 LEGENDEXISTING ELEVATION( )ACASPHALT PAVEMENTTEMPORARY BENCHMARKTBMWATER VALVEWVBLOCK WALLLCCENTERLINEGM GAS METERFSFLFINISHED SURFACEFLOWLINESET ON A WATER METER (WM)HUNTINGTON BEACH, CALIFORNIA 92646
PHONE:(714)488-5006 FAX:(714)333-4440
APEXLSINC@GMAIL.COM SEWER MANHOLESMHELEVATION = 10.99 FEETSURVEYOR OR ENGINEER SHALL PERMANENTLY MONUMENT PROPERTYCORNERS OR OFFSETS BEFORE STARTING GRADING.PLEASE CALL PAUL CRAFT @ 714-488-5006 TO SCHEDULE.SURVEYOR'S NOTESFFFINISH FLOORNG NATURAL GROUNDTOP OF CURBTCSEARCHED, FOUND NOTHING; SETNOTHINGTHE BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF VIA LIDO, BEINGN26°36'39"W PER P.M.B. 377/16-17.BFP BACK FLOW PREVENTORCLFCHAIN LINK FENCEEMHELECTRICAL MANHOLE EPEDGE OF PAVEMENTELPELECTRICAL PANELEPBELECTRICAL PULL BOXEGEDGE OF GUTTERMH MANHOLEPKL PARKING LIGHTSTREET LIGHT PULL BOXSLPBSTORM DRAIN MANHOLESDMHWATER METERWMWROUGHT IRON FENCEWIFCHAIN LINK FENCE (CLF)WROUGHT IRON FENCE (WIF)CATVCABLE TV BOXTILE SURFACEADAREA DRAINBSBOTTOM OF STEPNG~SA NATURAL GROUND; SANDSTREET LIGHTSLTOP OF BULKHEADTBTELEPHONE MANHOLETMHTOP OF STEPTSFOUND MONUMENT7/12/201924
DN
UP
2-CAR GARAGE 1
GREAT ROOM
FOYER
POWDER ELEVATOR DINING ROOM
KITCHEN
2-CAR GARAGE 2
W/C.MUD ROOM
BUTLER'S
KITCHEN
S.Y.S.B.7' - 6"S.Y.S.B.7' - 6"OCEAN F.Y.S.B.
10' - 0"
F.Y.S.B.
42' - 0"
1
2
3
4
VIA LIDO5
5
6 6
6
7
8
(E.) DOCK
(NOT-A-PART)
(E.) DOCK
(NOT-A-PART)N26°36'39"W 41.50'N26°36'39"W 52.07'N63°23'21"E 79.52'Δ=11°01'06"R= 275.66'L=53.01'Δ=04°50'00"R= 275.66'L=23.25'N26°36'39"W 18.27'N63°23'21"E 90.00'CLR.21' - 0"CLR.
21' - 6 3/8"CLR.21' - 3 3/4"CLR.
21' - 8 3/8"
POOL
9
9
9
10
11
SPA
(COVERED)
(COVERED)
YARD
12
12
12
12
12
12
38' - 0"
28' - 5 7/8"
13
13
14
10
POOL BATHF.O.F.3' - 10 7/8"F.O.F.3' - 11"F.O.F.5' - 3 7/8"F.O.F.5' - 6"(NOT-A-PART)
(E.) PARKING LOT
PLANTED
PLANTED PLANTED
(NOT-A-PART)
EXISTING STRUCTURE
15
16
BBQF.O.F.7' - 6 7/8"F.O.F.7' - 6 7/8"7' - 8 7/8"F.O.F.
12' - 3 1/2"
F.O.F.
24' - 9 1/4"
64' - 9 3/8"12' - 5 1/2"
52' - 3 1/8"12' - 6 1/4"
12' - 9 1/8"67' - 2 3/8"10' - 0 1/2"
21' - 4 7/8"40' - 3 1/2"5' - 6"
36' - 0 3/4"3' - 3"11 3/4"3' - 7"1' - 11"
9' - 10 1/4"2' - 8"
F.O.F.
10' - 0"9' - 0 1/2"76' - 9 1/2"7' - 8 7/8"F.O.F.9' - 0"2' - 8"17' - 1"2' - 8"32' - 2 1/2"1' - 11"18' - 4"1' - 11"F.O.F.
26' - 3 1/4"
F.O.F.
24' - 9 3/4"
6" MAX3"
F.O.F.
3' - 9"
F.O.F.
12' - 7 1/8"
12' - 9 1/8"
F .O .F.3 ' - 1 1 1 /4 "10' - 2"75' - 8"7' - 8 7/8"22' - 5"30' - 10"22' - 5"2' - 6"7' - 8"F.O.F.9' - 11 1/2"11.00' T.O.S.DN
10.00' T.O.S.
10.00' T.O.S.
10.00' T.O.S.
17 17
18 18
16.00' TW
(E.) 11.20 FS
16.00' TW
(E.) 10.50 BS
16.00' TW
(E.) 10.10 TS
14.75' TW
(E.) 9.28 BS
14.75' TW
(E.) 8.93 BS(E.) 8.93 FS
11.12' TW 11.12' TW
(E.) 7.62 FS
(BY SEP. PERMIT)
(BY SEP. PERMIT)
ENTRY
(COVERED)
19
19
20
(N.) DRIVEWAY APPROACH18' - 0"(N.) DRIVEWAY18' - 0"20
20
19
21
DN
REF. CIVIL DWGS.21
21
22
23
24
24REF. CIVIL DWGS.21
21
25
23
23
PATIO
LOGGIA
44' - 2 3/8"GAME ROOM F.O.F.7' - 6"18' - 8 3/4"4' - 9 3/4"7' - 8"POOL EQUIP.
S.
26
26
27
27 27
27
28
29
30 31 3030
31
30
31
31
30
31
31
3031
29
29
29
30
31
32 32
20
PARKWAY
PARKWAY
PARKWAY
(REF. CIVIL
PLANS)
(REF. CIVIL
PLANS)
(REF. CIVIL
PLANS)
10.60' TB10.00' TW
NOTE: CONTINUOUS WATERPROOFING TO EXTEND TO 10.60'
ELEV. THROUGHOUT FIRST FLOOR WITH T.O.S. LOWER THAN
10.60' TO ADDRESS SLR PER CCC -REF. DTL. 6/AD-1
NOTE: CONTINUOUS WATERPROOFING TO EXTEND TO 10.60'
ELEV. THROUGHOUT FIRST FLOOR WITH T.O.S. LOWER THAN
10.60' TO ADDRESS SLR PER CCC -REF. DTL. 6/AD-1
PUE
4' - 0"
33
33
33
PROPOSED ACCESS POINT FOR THE NEW
DOCK'S ACCESS -PROVIDE 42" HIGH GUARD
ABV. FS/FG UNTIL AFTER THE NEW DOCK'S
ACCESS CONSTRUCTED
93' - 6 7/8"94.53'OVERALL LENGTH OF FRONT PROPERTY LINE2 1/2"
3' - 9 1/2"
25
CLR.3' - 8 3/8"13.38'
TRASH
ON-STREET PARKING
SPACE (19'), PER PUBLIC
WORKS
5' MIN. HT. FROM OUTSIDE
GLASS FENCE/POOL BARRIER 5' MIN. HT. CONT.GLASS FENCE/POOL BARRIER5' MIN. HT. FROM OUTSIDE
GLASS FENCE/POOL BARRIER
5' MIN. HT. CONT.GLASS FENCE/POOL BARRIER(N.) STREET
LIGHT LOC'N.,
REF. CIVIL DWGS.
34
34
JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT
A-0.0
7/19/19
201837ARCHITECTURAL SITE PLANSTUPIN RESIDENCE
STUPIN RESIDENCEAMDREW & JULIE STUPINC/O. COASTLINE REALESTATE INVESTMENTS215TH STREETHUNTINGTON BEACHCA 92648CDP
3322 VIA LIDO, NEWPORT BEACH, CA 92663JUSTIN JONHSTON
JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT
A-0.0
7/19/19
201837ARCHITECTURAL SITE PLANSTUPIN RESIDENCE
STUPIN RESIDENCEAMDREW & JULIE STUPINC/O. COASTLINE REALESTATE INVESTMENTS215TH STREETHUNTINGTON BEACHCA 92648CDP
3322 VIA LIDO, NEWPORT BEACH, CA 92663JUSTIN JONHSTON
KEYNOTE LEGEND
1 CABLE TV JUNCTION BOX (REF. SURVEY & CIVIL)
2 (E.) STREET LIGHT PULL BOX - REF. SURVEY AND CIVIL DWGS.
3 (E.) ELECTRICAL MANHOLE - REF. SURVEY AND CIVIL DWGS.
4 (E.) TELEPHON MANHOLE - REF. SURVEY & CIVIL DWGS.
5 (E.) STREET LIGHT - REF. SURVEY AND CIVIL DWGS.
6 (E.) GAS METER LOCATION, TO BE RELOCATED (REF. SURVEY & CIVIL DWGS.)
7 (E.) WATER VALVE (REF. SURVEY & CIVL DWGS.)
8 CENTERLINE/FLOWLINE OF ALLEY/AVENUE
9 PROPERTY LINE
10 SIDE YARD SETBACK
11 OCEAN FRONT SETBACK
12 FOOTPRINT OF EXISTING STRUCTURE, TO BE REMOVED
13 VEHICLE - MINIMUM PARKING DIMENSIONS ON PLANS
14 FRONT YARD SETBACK
15 EXISTING STRUCTURE - NOT A PART
16 BBQ AS SELECTED. - PROVIDE GAS S.O. & POWER AS REQ'D. BY MFGR. - VERIFY W/. OWNER
17 (E.) PROPERTY LINE WALL & WROUGHT IRON FENCE, REF. SURVEY & CIVIL DWGS. - PROTECT IN
PLACE
18 (N.) CMU PROPERTY LINE WALL W/. STUCCO FINISH - PAINT AS SELECTED (MAX. 6' ABV. N.G., 42" MAX
@ F.Y.S.B) [WALL AND FOOTING ON OWNER'S SIDE]
19 (E.) DRIVEWAY APPROACH OR CURB CUT TO BE REMOVED - REF. SURVEY & CIVL DWGS.
20 NEW DRIVEWAY APPROACH AND/OR CURB CUT - REF. CIVIL DWGS.
21 HARDSCAPE PER LANDSCAPE ARCHITECT/DESIGNER - STONE PAVERS OVER CONCRETE SLAB, REF.
LANDSCAPE DWGS. (VERIFY W/. OWNER)
22 HARDSCAPE PER LANDSCAPE ARCHITECT/DESIGNER - COLORED & SCORED CONC., REF. LANDSCAPE
DWGS. (VERIFY W/. OWNER)
23 PLANTED AREA PER LANDSCAPE ARCHITECT/DESIGNER - REF. LANDSCAPE DWGS., COORDINATE
WITH LANDSCAPE DESIGNER/ARCHITECT
24 NEW DRIVEWAY , PAVEMNT PER LANDSCAPE - REF. CIVIL & LANDSCPAE DWGS. (VRIFY W/. OWNER)
25 LANDSCAPE PAVING SYSTEM PER LANDSCAPE ARCHITECT/DESIGNER - 'TURFBLOCK'/'GRASSCRETE'
OR EQUIV., REF. LANDSCAPE DWGS. (ARCH. & OWNER TO APPROVE)
26 (N.) WOOD GATE PER LANDSCAPE - AS SELECTED (MAX. 6' HT. ABOVE NATURAL GRADE)
27 A/C. CONDENSER UNIT - SIZE TBD - PROVIDE POWER AND SOUND DAMPENING PAD AS REQ'D.
(SOUND ATT. REQ'D. PER SECTION 10.26.045 NBMC UNDER SEPARATE PERMIT)
28 TRASH LOCATION - SCREEN FROM STREET AS NEEDED
29 DOWNSPOUT - COPPER/ALUMINUM W/. KYNAR FINISH OR EQUIV. - AS SEL. (ARCH. TO APPROVE)
30 DRAIN LINE - IN WALL/FROM ABV. (REF. CIVIL DWGS. & DETAILS)
31 OVERFLOW DRAIN - REF. DTL. 11/AD-1
32 HARDSCAPE PER LANDSCAPE ARCHITECT/DESIGNER - STONE PAVERS, REF. LANDSCAPE DWGS.
(VERIFY W/. OWNER)
33 EXTERIOR GLASS GUARDRAIL - MIN. 42" HEIGHT - 4" MAX. SPHERE OPENING, REF. DTL. 9 & 13/AD-1
34 (N.) STREET TREE - 36" BOX STREET TREE, REF. LAND. & CIVIL DWG.'S
NO. REVISION DATENO. REVISION DATE
PROJECT NORTHTRUE NORTH
1/4" = 1'-0"1 ARCHITECTURAL SITE PLAN
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.)
TYP. U.N.O. ROUNDED TO THE NEAREST 1/8" -CONTACT ARCHITECT IN WRITING FOR ANY
CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
LANDSCAPE NOTES:
1. ENCOARCHMENT PERMIT REQ'D. FOR ANY WORK PROPOSED IN THE PUBLIC R.O.W.
2. IF APPLICABLE, REF. PRELIMINARY LANSCAPE PLAN, FOR ALL HARDSCAPE & PLANTING
AREAS WITH REPECTIVE HEIGHTS AND MATERIALS.
GENERAL NOTES:
1. SEE SHEET A-3.0.0 FOR ROOF PLAN INFORMATION NOT SHOWN ON THIS SHEET (INCLUDING
EAVE DETAILS AND PROJECTION DISTANCES).
2. FENCES, HEDGES, WALLS, RETAINING WALLS, GUARDRAILS AND HANDRAILS OR ANY
COMBINATION THEREOF SHALL NOT EXCEED 42 INCHES FROM EXISTING GRADE PRIOR TO
CONSTRUCTION WITHIN THE REQUIRED FRONT SETBACK AREA(S).
C.N.B. NOTES:
1. ISSUANCE OF A BUILDING PERMIT BY THE CITY OF NEWPORT BEACH DOES NOT RELIEVE
APPLICANTS OF THE LEGAL REQUIREMENTS TO OBSERVE COVENANTS, CONDITIONS AND
RESTRICTIONS WHICH MAY BE RECORDED AGAINST THE PROPERTY OR TO OBTAIN PLANS YOU
SHOULD CONTACT YOUR COMMUNITY ASSOCIATIONS PRIOR TO COMMENCEMENT OF ANY
CONSTRUCTION AUTHORIZED BY THIS PERMIT.
2. PRIOR TO PERFORMING ANY WORK IN THE CITY RIGHT-OF-WAY AN ENCROACHMENT PERMIT
MUST BE OBTAINED FROM THE PUBLIC WORKS DEPARTMENT.
3. A CAL-OSHA PERMIT IS REQUIRED FOR EXCAVATIONS DEEPER THAN 5' AND FOR SHORING
AND UNDERPINNING.
25
UPΔ=04°50'00"R=275.66'L=23.25'Δ=11°01'06"R=275.66'L=53.01'
LOT 1
TRACT NO. 1622
M.M. 47/39
PARCEL 2
P.M.B. 2009-125
VIA LIDON63°23'21"E 90.00'N26°36'39"W 18.27'N63°23'21"E 79.52'N26°36'39"W 52.07'N26°36'39"W 41.50'℄N63°23'21"E 89.02'
(9.62)
EG
(10.08)
AC (10.14)TC
(9.46)FL
(10.16)TC
(9.50)FL
(10.39)TC
(9.82)FL
(10.24)TC
(9.56)FL
(10.41)TC
(9.94)FL
(10.80)TC
(10.60)FL
(10.96)TC
(10.48)FL
(10.63)
EG
(10.49)
EG
(10.29)
EG
(10.16)
FL
(10.09)
EG
(9.94)
EG
(9.67)EG
(9.79)EG
(9.71)FL
(10.20)
AC
(10.62)
AC
(10.87)
AC
(7.94)
FS
(9.66)
FS
(9.63)
FS
(9.52)
FS(9.58)
FS
(9.50)
FS
(9.65)
FS
(9.81)FS
(9.83)FS
(9.76)
FS
(9.93)
FS
(10.03)FS
(9.76)
FS
(10.40)FS
(10.36)FS
(10.34)
FS
(10.29)
FS
(10.16)FS (9.26)FS
(11.59)
EP
(11.80)
AC
(11.95)
EP
(11.07)FS
(11.20)FS
(11.25)
FS
(10.09)
FS
(10.07)FS (9.16)FS (8.42)FS
(8.40)FS
(9.73)
FS
(9.22)FS(9.32)FS(9.47)FS(10.66)FS
(11.11)
FS(10.96)
NG
(10.67)
FS
(10.39)TC
(10.39)FL
(10.02)
EG (10.18)FSFS (9.46)
FS(10.53)
NG
NG
(10.07)NG
(9.85)FS
(9.64)
FS
(9.73)FS
(27.69)
CHIMNEY TOP
(9.22)
FF
(32.71)
RIDGE
(10.10)
TS
(9.68)
FF
(9.48)
AD
(9.10)FS (8.93)FS
(8.87)FS
(9.28)BS (7.50)BS(9.33)
FF
(8.85)
FS
(9.17)
FS
(7.50)FS(8.92)TS(9.08)
FS
(8.81)
FS(10.23)TW(10.22)TW(9.13)FS(9.18)FS(7.61)FS
(10.40)FS(10.51)BS
(11.20)
FFG
(11.11)
FS(10.74)NG(10.66)FS
(9.21)BS(10.05)TS(10.21)BS(11.05)TS
(10.60)
FFG(10.46)FS(30.73)
RIDGE
(10.99)WM(10.70)SLPB(10.78)
WV
(10.96)
WV (10.40)SLPB(9.91)
TMH
(9.96)
EMH (10.18)
SLPB
(10.21)
CATV
(7.61)TB
(-1.40)NG~SA(7.63)TB(-3.40)NG~SA(7.60)TB
(-4.13)NG~SA
(7.51)TB
(-4.69)NG~SA
(7.48)TB
(-3.49)NG~SA
(9.28)
FS
(7.55)
TB
(9.47)
AD
(8.41)BS (9.72)TS
(9.51)
FS
(9.41)
AD
(1.79)
DOCK
(1.86)
DOCK
(1.74)
DOCK
(1.64)
DOCK
(7.65)
TB
(7.62)
FS
(10.92)
CATV
(10.93)
FS
(10.66)
SCO
(11.17)FSEXISTING
BUILDING
EXISTING
BUILDING
PROPERTY
LINE
PROPERTY
LINE
PROPERTY
LINE
PARKING LOT
DOCK
DOCK
6' TALL
WALL
6' TALL FENCE
5' TALL WALL
GM
GMSL STAIRS
PROPERTY
LINE
PROPERTY
LINE
FOUND
MONUMENT
FOUND
MONUMENT
CURB & GUTTER
POINT #1
9.63 FS
POINT #2
9.08 FS
POINT #3
11.17 FS
POINT #4
10.60 FFG
GRADE PLANE EXHIBIT:
POINT #1: 9.63 FS
POINT #2: 9.08 FS
POINT #3: 11.17 FS
POINT #4: 10.60 FFG
GRADE PLANE = 40.48/4 = 10.12
AVERAGE SLOPE = 11.17 -9.08/67.40 = 3.10 %
67.40'
JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT
A-0.3
7/19/19
201837GRADE PLANE EXHIBITSTUPIN RESIDENCE
STUPIN RESIDENCEAMDREW & JULIE STUPINC/O. COASTLINE REALESTATE INVESTMENTS215TH STREETHUNTINGTON BEACHCA 92648CDP
3322 VIA LIDO, NEWPORT BEACH, CA 92663JUSTIN JONHSTON
NO. REVISION DATE
PROJECT NORTHTRUE NORTH
3/16" = 1'-0"1 GRADE PLANE EXHIBIT
26
DW T
DW T
WD D
2948 SF
FIRST FLOOR AREA
487 SF
GARAGE 2
496 SF
GARAGE 1
521 SF
REAR YARD
255 SF
ENTRY
28 SF
PLANTED
111 SF
PLANTED
77 SF
PLANTED
10 SF
PLANTED
44 SF
PLANTED 86 SF
PLANTED
221 SF
PLANTED
168 SF
PLANTED
283 SF
LOGGIA
336 SF
PATIO
251 SF
DRIVEWAY
A F
B
E
C
G
H
K
J
L
D
M N O
21' - 4 7/8"1' - 2 1/2"29' - 7 3/4"4' - 5 1/4"
22' - 7 3/8"29' - 7 3/4"
2' - 3 3/8"20' - 4"28' - 3 3/4"6"21' - 5"6"4' - 9 3/4"10' - 11 5/8"10' - 6 1/4"10' - 7 7/8"19' - 3 3/4"
2' - 3 3/8"20' - 4"21' - 7 1/4"9 3/4"22' - 5 3/8"28' - 5 3/4"1' - 4"22' - 5"21' - 7 1/4"31' - 7 3/4"24' - 11"A -21' -4 7/8" X 6" = 10.70 GARAGE
B -22' -7 3/8" X 21' -5"= 484.33 GARAGE
C -2' -3 3/8" X 6"= 1.14 GARAGE
D -1' -2 1/2" X 3' -0" = 3.63
E -29' -7 3/4" X 24' -11" = 738.68
F -4' -5 1/4" X 4' -9 3/4" = 21.36
G -20' -4" X 10' -7 7/8" = 216.68
H -19' -3 3/4" X 10' -6 1/4"= 203.18
J -28' -3 3/4" X 31' -7 3/4" = 895.97
K -20' -4" X 10' -11 5/8" = 223.03
L -2' -3 3/8" X 9 3/4"= 1.85 GARAGE
M -22' -5 3/8" X 21' -7 1/4" = 484.97 GARAGE
N -28' -5 3/4" X 21' -7 1/4" = 615.27
O -1' -4" X 22' -5" = 29.89
LIVING = 2,947.69
GARAGE = 982.99
TOTAL = 3930.683' - 0"3823 SF
SECOND FLOOR
AREA
416 SF
REAR YARD 2
245 SF
DRIVEWAY 2
138 SF
MASTER BALCONY
181 SF
OFFICE/GYM
BALCONY
A B
C D E
F
G
H J
K
L M N
2' - 0 1/4"21' - 4 7/8"30' - 10 1/4"9' - 3 3/4"3' - 7 1/4"10' - 7 7/8"22' - 5"24' - 11 1/8"18' - 5"17' - 10 1/8"9 3/8"28' - 10 5/8"
2' - 0 1/8"7' - 4 3/4"5' - 9 3/4"4' - 11"10' - 1 3/8"4' - 6 1/2"2' - 0 1/4"52' - 3 1/8"6' - 10 1/2"10' - 7 7/8"22' - 5"15' - 5"30' - 9 7/8"A -2' -0 1/4" X 10' -7 7/8" = 21.53
B -21' -4 7/8" X 22' -5" = 479.86
C -30' -10 1/4" X 24' -11 1/8" = 769.10
D -9' -3 3/4" X 18' -5" = 171.51
E -3' -7 1/4" X 17' -10 1/8" = 64.31
F -9 3/8" X 20' -8 5/8" = 16.19
G -28' -10 5/8" X 30' -9 7/8" =890.33
H -2' -0 1/8" X 4' -11" = 9.88
J -7' -4 3/4" X 10' -1 3/8"= 74.81
K -5' -9 3/4" X 4' -6 1/2" = 26.40
L -2' -0 1/4" X 10' -7 7/8" = 21.53
M -52' -3 1/8" X 22' -5" = 1171.50
N -6' -10 1/2" X 15' -5" = 105.99
TOTAL = 3822.95 SF20' - 8 5/8"1097 SF
THIRD FLOOR AREA
A
B
C D
E
F
G
H
J
5' - 3 7/8"21' - 11 3/4"6' - 3"16' - 1"7' - 7 1/2"11' - 1 3/8"15' - 5 3/4"3' - 10 1/4"4' - 11 3/8"21' - 2 3/4"7' - 1 7/8"8' - 9 7/8"10' - 3 1/4"10' - 9"
19' - 9 1/4"
5' - 11 1/8"
5' - 1 7/8"
6"
A -5' -3 7/8" X 8' -9 7/8" = 46.96
B -21' -11 3/4" X 16' -1" = 353.50
C -11' -1 3/8" X 7' -1 7/8" = 79.54
D -7' -7 1/2" X 6' -3" = 47.66
E -5' -11 1/8" X 21' -2 3/4" = 125.83
F -5' -1 7/8" X 4' -11 3/8" = 25.51
G -6" X 3' -10 1/4" = 1.93
H -10' -9" X 10' -3 1/4" = 110.41
J -19' -9 1/4" X 15' -5 3/4" = 306.04
TOTAL = 1097.37 SF
JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT
A-0.4
7/19/19
201837AREA PLANSSTUPIN RESIDENCE
STUPIN RESIDENCEAMDREW & JULIE STUPINC/O. COASTLINE REALESTATE INVESTMENTS215TH STREETHUNTINGTON BEACHCA 92648CDP
3322 VIA LIDO, NEWPORT BEACH, CA 92663JUSTIN JONHSTON
NO. REVISION DATE
1/8" = 1'-0"1 FIRST FLOOR AREA PLAN
1/8" = 1'-0"2 SECOND FLOOR AREA PLAN
1/8" = 1'-0"3 THIRD FLOOR AREA PLAN
BUILDING AREA SCHEDULE
NAME AREA COMMENTS
FIRST FLOOR AREA 2948 SF
SECOND FLOOR AREA 3823 SF
THIRD FLOOR AREA 1097 SF
7868 SF
GARAGE 2 487 SF
GARAGE 1 496 SF
983 SF
GRAND TOTAL 8850 SF
OUTDOOR AREA SCHEDULE
NAME AREA COMMENTS
REAR YARD 521 SF PARTIAL COVER
ENTRY 255 SF COVERED
LOGGIA 283 SF COVERED
PATIO 336 SF COVERED
DRIVEWAY 251 SF
REAR YARD 2 416 SF
DRIVEWAY 2 245 SF
MASTER BALCONY 138 SF
OFFICE/GYM BALCONY 181 SF
GRAND TOTAL 2628 SF
LANDSCAPE AREA SCHEDULE
NAME AREA COMMENTS
PLANTED 745 SF
GRAND TOTAL 745 SF
TOTAL LIVING
TOTAL GARAGE
GRAND TOTAL
GRAND TOTAL
GRAND TOTAL
LEGAL DESCRIPTION:
LOT INFORMATION:
ZONED: RM
SITE AREA:8,160.15 S.F. BUILDABLE AREA: 5,778.25 S.F.
TOTAL ALLOWABLE AREA: 1.75 X 5,778.25 S.F. = 10,110.19 S.F.
MIN. OPEN VOLUME REQ'D: 5,778.25 S.F. X 15% = 866.74 S.F.
OPEN VOLUME PROVIDED: 2,628 S.F.> 866.74 S.F.
EXISTING BUILDING INFORMATION:
THE EXISTING TWO-UNIT RESIDENTIAL CONDOMINIUM STRUCTURE
AND FOUR-UNIT RESIDENTIAL APARTMENT STRUCTURE DEMOLISHED,
REF. ZA2018-097, NP2018-012, CD2018-045, AND PA2018-100
ZONING INFORMATION:
FRONT SETBACK: 4 FT.
OCEAN FRONT SETBACK: 10 FT.
LEFT SETBACK: 7'-6" FT. (0.08 X 93.57' = 7.48')
RIGHT SETBACK: 7'-6" FT. (0.08 X 93.57' = 7.48')
APN: 423-123-12 & 423-123-21
THE PROPERTY AT 3312-3318 VIA LIDO IS LEGALLY DESCRIBED AS LOTS
1 AND 2 OF TRACT 1622, IN THE CITY OF NEWPORT BEACH, COUNTY OF
ORANGE, STATE OF CALIFORNIA, AS PER MAP RECORDED IN BOOK 47,
MISCELLANEOUS MAPS, IN THE OFFICE OF THE COUNTY ASSESSOR OF
SAID COUNTY. EXCEPT THE NORTHWESTERLY 28 FEET OF SAID LOT 2.
THE PROPERTY AT 3322 AND 3324 VIA LIDO IS LEGALLY DESCRIBED AS
PARCEL 2 OF PM2009-125, IN THE CITY OF NEWPORT BEACH, COUNTY OF
ORANGE, STATE OF CALIFORNIA, AS PER MAP RECORDED IN BOOK 373,
PAGES 21 & 22 OR SAID PARCEL MAPS IN THE OFFICE OF THE COUNTY
RECORDER OF SAID COUNTY. PROPERTIES CONSOLIDATED TO ONE
PARCEL REF. ZA2018-097, NP2018-012, CD2018-045, AND PA2018-100
27
28
29
(* )
(* )
NOTE :
A
PMA Consulting, Inc.Consulting Structural Engineers28161 Casitas Ct., Laguna Niguel, CA 92677Phone: (714) 717-7542E-Mail: P.Petrov@PMA-BG.comREINFORCE THE EXISTINGSEAWALL/BULKHEAD LOCATED AT:3324 VIA LIDONEWPORT BEACH, CA 92663ANDREW AND JULIE STUPIN215 5th STREET, SUITE AHUNTINGTON BEACH, CA 92648PRELIMINARY FOR AICSW-2A 30
SECTION
PLAN
NOTES:
SECTION
1
1
AA
PMA Consulting, Inc.Consulting Structural Engineers28161 Casitas Ct., Laguna Niguel, CA 92677Phone: (714) 717-7542E-Mail: P.Petrov@PMA-BG.comREINFORCE THE EXISTINGSEAWALL/BULKHEAD LOCATED AT:3324 VIA LIDONEWPORT BEACH, CA 92663ANDREW AND JULIE STUPIN215 5th STREET, SUITE AHUNTINGTON BEACH, CA 92648PRELIMINARY FOR AICSW-3A 31
32
33
0 8 16 24 32 40 48
GRAPHIC SCALE
SCALE: 1/8" = 1'-0"
NORTH
POOL EQUIP.
P
O
O
L
SPA
DOCK RAMP
DW T
DW TDWTGARAGE 1
GARAGE 2
POWDER
MUD ROOM
FOYER
BUTLER'S
KITCHEN
KITCHEN
DINING ROOM
GREAT ROOM
GAME ROOM
ELEVATOR
POOL BATH
W/C.
11.00' T.O.S.10.00' T.O.S.
UP
10.60' TB
10.00' TW
VIA LIDO SYMBOL QUANTITY
CAM-YUL 5
FEI-SEL 1
HEL-ARB 2
ELA-DEC 14
OLE-DWF 0
RAP-MIN 12
ROS-ICE 9
SAN-TRI 4
SCA-AEM 10
SEN-SER 24
SES-AUT 22
SOL-JAS 5
WIS-ROS 2
SYMBOL BOTANICAL NAME COMMON NAME SIZE DESCRIPTION
TREES
MAY-BOA MAYTENUS BOARIA MAYTEN TREE 36” BOX EVERGREEN TREE TO 25 FT. WITH WEEPING HABIT. PRUNE TO DESIRED SHAPE.
WIS-ROS WISTRINGIA ROSMARINIFORMIS WESTRINGIA FIVE GAL.EVERGREEN SHRUB TO 5 FT. WITH SMALL WHITE FLOWERS AND ROSEMARY LIKE FOLIAGE.
SENECIO SERPENS PUNK PICKLE SEN-SER ONE GAL.SUCCULENT PERENNIAL WITH LIGHT BLUISH GRAY LEAVES, MASS PLANT AS GROUND COVER.
FEJ-SEL FEIJOA SELLOWIANA PINEAPPLE GUAVA 24” BOX FAST GROWING EVERGREEN SHRUB / TREE W/ WHITE FLOWERS AND GRAY-GREEN FOLIAGE , EDIBLE FRUIT (MULTI TRUNK).
MET-EXC METROSIDEROS EXCELSA NEW ZEALAND CHRISTMAS TREE 24” BOX EVERGREEN W/ EXCEPTIONAL INTEREST. SUPERB, BARK, DARK RED FLOWERS SET WITHIN THE DARK GRAYISH BODY OF FOLIAGE.
AJU-REP AJUGA REPTANS ATRO BRONZE AJUGA 6"0.C.LOW GROWING GROUND COVER WITH BRONZE LEAVES AND BLUE FLOWER SPIKES TO 6”.
ROS-ICE ROSA ICEBERG (CLIMBER WHEN SPECT.)ICEBERG ROSE FIVE GAL PROFUSE WHITE BLOOMING ROSE, EXCELENT ON FENCES. (CLIMBING WHERE SPECIFIED)
GROUND COVER
SYMBOL BOTANICAL NAME COMMON NAME SPACING DESCRIPTION
COLOR ANNUAL COLOR SEASONAL - 4" POT SIZE 10" O.C. CONTRACTOR TO PLANT A MINIMUM OF ____ FLATS OF COLOR FOR THIS PROJECT
OPH-NAN OPHIOPOGON JAPONICUS 'NANUS'DWARF MONDO GRASS 3"0.C.LUMPING PERENNIAL GRASS LIKE FOLIAGE TO 3” W/ LILAC FLOWERS. GREAT LAWN SUBSTITUTE
SCA-AEM SCAEVOLA AEMULA BLUE WONDER ONE GAL.SPRAWLING SHRUB / GROUND COVER W/ SMALL LIGHT GREEN LEAVES AND ABUNDENT BLUE FLOWERS.
SHRUBS
SYMBOL BOTANICAL NAME COMMON NAME SIZE DESCRIPTION
CAM-YUL CAMELLIA SASANGUA YULETIDE SASANQUA CAMELLIA 15 GAL.DEEP ROSE-PINK FLOWER ON COMPACT, UPRIGHT SHRUB TO 3’
SOL-JAS SOLANUM JASMINOIDES POTATO VINE / JASMINE NIGHTSHADE FIVE GAL.EVERGREEN TWINING VINE W/ PERPETUAL BLOOM OF STAR SHAPED WHITE FLOWERS. (DEER RESISTANT)
HEL-ARB HELIOTROPIUM X 'MARINE'HELIOTROPE FIVE GAL.SUB-TROPICAL EVERGREEN SHRUB TO 30" W/ DEEP DARK GREEN LEAVES W/ COBALT BLUE FLOWERS.
SAN-TRI SANSECIERIA TRIFASCIATA 'BLACK GOLD'BLACK GOLD SANSECIERIA FIVE GAL.UPRIGHT PERENNIAL W/ 30 IN. LONG STIFF DARK GREEN LEAVES W/ YELLOW MARGIN FROM BASE.
RAP-MIN RAPHIOLEPIS UMBELLATUS ‘MINOR’DWARF YEDDA HAWTHORNE FIVE GAL.SLOW GROWING COMPACT UPRIGHT SHRUB TO 4 FT. W/ WHITE FLOWER CLUSTERS.
ELA-DEC ELAEOCARPUS DECIPIENS 'MONPROUD'LITTLE EMPEROR JAPANESE BLUEBERRY 15 GAL.UPRIGHT EVERGREEN SHUB TO 8 FT. WITH GLOSSY GREEN FOLIAGE THAT TURNS BRIGHT RED BEFORE DROPPING.
· TURF AREA DOES NOT EXCEED 25% OF LANDSCAPE
PLANTING AREA (PROHIBITED ON SLOPE AREAS AND
PARKWAYS LESS THAN 10 FEET WIDE)
· 75% OF LANDSCAPE AREA MUST BE PLATED WITH
CLIMATE ADAPTED PLANTS WITH AN AVERAGE WUCOLS PLANT
FACTOR OF 0.3.
· COMPOST AT A RATE OF FOUR CUBIC YARDS PER 1,000
SQUARE FEET TO A DEPTH OF SIX INCHES
3-INCH MULCH LAYER APPLIED TO ALL PLANTING AREAS
(EXCLUDING TURF AREAS)
AUTOMATIC IRRIGATION CONTROLLERS WITH MANUAL SHUT-OFF
VALVES
STATEMENT, “OWNER TO AGREE TO COMPLY WITH THE
REQUIREMENTS OF THE PRESCRIPTIVE COMPLIANCE OPTION TO
THE MWELO).”
SESLERIA AUTUMNALIS AUTUMN MOOR GRASSSES-AUT ONE GAL.GRASS TO 20" TALL, BEARS SPIKE-LIKE SILVER-WHITE (TURNING GOLDEN) FLOWER TASSELS
SYNTHETIC TURF SPECIFINCATION
YARN TYPE
PRIMARY: POLYETHYLENE MONOFILAMENT MEMORY FIBER™
SECONDARY: HEAT SET TEXTURED NYLON MONOFILAMENT
YARN COLOR
PRIMARY: FIELD/OLIVE GREEN
SECONDARY: TURF GREEN/DARK TAN
YARN COUNT: PRIMARY: 10,800/6 SECONDARY: 5,040/12
TUFTING CONSTRUCTION: DUAL YARN, SAME ROW
BLADE HEIGHT: 2-1/8″
TUFTING GAUGE: 3/8″
FACE WEIGHT: 70 OUNCES
TOTAL PRODUCT WEIGHT: 135 OUNCES
BACKING
PRIMARY: 18 PIC REINFORCED TRI-COMPONENT
SECONDARY: 50 OUNCE BIOCEL™ POLYURETHANE, WITH 6
OUNCE NON-WOVEN GEOTEX LAMINATE
SEAMING: MICROMECHANICAL BONDING
INFILL: 0.75 POUNDS OF RUBBER (OR SAND/RUBBER MIX)
LAG-IND LAGERSTROEMIA INDICA 'NATCHEZ'CRAPE MYRTLE 36” BOX DECIDUOUS SMALL TREE NOTED FOR PROLIFIC CLUSTERS OF SHOWY WHITE FLOWERS W/ SMOOTH SHINY TRUNK.
TREE PLANTING DETAIL
TWICE ROOT
BALL WIDTH 18" MIN.1. CLINCH TIE OR EQUAL (4 REQ'D)
2. 10' LODGE POLE STAKES, STAKE
SHALL CLEAR ROOT BALL BY 2"
TREATED W/ COPPER NAPTHANATE,
PLACE AT RIGHT ANGLES TO
PREVAILING WINDS.
3. VENTILATED TRUNK GUARD
IN TURF AREAS
4. TOP OF ROOT BALL TO BE
1 1/2" ABOVE FINISH GRADE.
5. 4" HIGH WATERING BERM.
6. 2" THICK MULCH LAYER. PER SPEC.
7. FERTILIZER & MYCORRHIZAE TABS
(SEE SPECS.)
8. ROUGHEN SURFACE OF ROOT BALL
PRIOR TO PLANTING.
1
2
3
4
5
6
7
8
NOTE: ALL TREES PLANTED WITHIN FIVE FEET OF HARDSCAPE SHALL HAVE
A ROOT BARRIER DEVICE INSTALLED ADJACENT TO HARDSCAPE AREA.
2 X
BALL
DIA.
SHRUB PLANTING DETAIL
NOTE: UNTANGLE MATTED ROOTS BY LOOSENING ALL ROOTS AT EDGE OF
ROOT BALL WITH WATER FROM HOSE. DO NOT CRACK ROOT BALL..
1
2
3
4
5
6
7
1. CROWN OF PLANT TO BE
1" ABOVE FINISH GRADE
2. 4" HIGH TEMPORARY BASIN.
3. 2" THICK SHREDDED MULCH DO NOT
USE BARK CHIPS WHERE PLAN CALLS
FOR MULCH COVER.
4. FERTILIZER AND MYCORRHIZAE
TABS (SEE SPECS.)
5. BACKFILL MIX (SEE SPECS.)
6. DIG HOLE A MIN. OF 1 1/2 X THE DEPTH
OF THE PLANT CONTAINER
7. COMPACTED BACKFILL PER SPEC.
E L E V A T I O N
LEGEND
1. WALL
2. EYEBOLTS: 3/8" DIA. EYEBOLTS IN LEAD SHIELDS,
PROVIDE 6.
3. FINISH GRADE
4. 12 GA. GALV. WIRE: SECURE VINE TO WIRE WITH
NURSERYMAN'S TAPE.
5. ANGLE TRUNK OF VINE BACK TO WALL AND
REMOVE STAKE & TIE.
NOTE: WHEN PLANTING SEVERAL VINES ON ONE WALL,
WIRE TRELLIS SHALL BE CONTINUOUS.
VINE DETAIL
NON-ADHERING TYPE24" TYP.1
2
3
4
5
EDGE OF PLANTING
2/3 O.C.
SPACING
EQUAL EQUALSPACING O.C.NOTE: ALL MASS PLANTED SHRUBS AND GROUND
COVER SHALL BE PLANTED AT EQUAL SPACING
(TRIANGULAR) UNLESS OTHERWISE INDICATED ON
PLANS. SEE LEGEND FOR SPACING REQUIREMENTS.
MULCH ALL PLANTING AREAS PER SPEC.
GROUND COVER AND
SHRUB SPACING
SPECIMEN TREE PLANTING DETAIL
LEGEND
1. SPECIMEN TREE, 36" BOX OR LARGER
2. BLACK PVC HOSE WITH 1/8" BRAIDED GALVANIZED STEEL GUY CABLE, USE GALVANIZED
CABLE CLAMPS AND TURNBUCKLE, MINIMUM 3 GUYS.
3. 1/2" DIA. X 2" LONG WHITE PVC WARNING DEVICE - TO BE INSTALLED IN PUBLIC AREAS.
4. WATER BASIN- MINIMUM 4" DEPTH, MULCH TO 2" DEPTH AND DEEP WATER TREE
IMMEDIATELY UPON PLANTING. REMOVE BASIN AT END OF MAINTENANCE PERIOD.
5. FINISH GRADE, CROWN OF TREE MUST NOT BE PLANTED BELOW THIS LEVEL.
6. AMMENDED BACKFILL MIX - SEE SPECIFICATIONS. TAMP AND SETTLE BACKFILL BEFORE
PLANTING SO THAT TREE DOES NOT SINK AFTER PLANTING. BOTTOM 8" UNDER TREE
SHALL BE WASHED SAND.
7.TREE ROOTBALL - MUST NOT BE ROOT BOUND. LOOSEN ANY TIGHT PACKED ROOTS.
TWICE ROOT
BALL WIDTH
10. MODEL 68 DUCKBILL EARTH ANCHOR WITH 1/8"
BRAIDED GALVANIZED STEEL CABLE. INSTALL
PER MFG. SPECIFICATIONS.
11. ROOTBALL DEPTH PLUS 8" FOR WASHED SAND
IF BEDROCK IS ENCOUNTERED DIG AN ADDITIONAL 18".
1
2
3
4
5
6
7
8
9 10
11
9. FERTILIZER TABLETS - SEE SPECIFICATIONS
8. EMPTY 3" DIAMETER PERFORATED PVC DRAIN PIPE FOR
AIR AND WATERING, PLACE MIN. 3 PER TREE.
12. 12" Ø AUGURED HOLE X 6' DEEP
FILL WITH WASHED SAND.12
NOTE: ALL TREES PLANTED WITHIN FIVE FEET OF HARDSCAPE SHALL HAVE A ROOT
BARRIER DEVICE INSTALLED ADJACENT TO HARDSCAPE AREA.
CY
PLANTING PLANSYNTHETIC TURF TO BE DUPONT
SELECT LX BY FOREVERLAWN,
CONTACT PAUL MC CAUGHEY
909-81`6-4688 FOR INSTALLATION.
RM
CY
RI
RI
RI
RI
RI
RI
CY
CY
H
H
E E E E E E E E E E E E E E RM RM RM RM
RM RM RM RM RM RM RM
WR
WR
S
S
SS
S
S
S
S
S
S
WIS-ROS
SEN-SER
ELA-DEC RAP-MIN SES-AUT
OPH-NAN
MAY-BOA
MAY-BOA
OPH-NAN
SES-AUT
FEI-SEL
WIS-ROS
RAP-MIN
SOL-JAS SAN-TRIAJU-REP
CAM-YUL
ROS-ICESEN-SER
SYNTHETIC
TURF
SES-AUT
CAM-YUL
HEL-ARB
ROS-ICE
CAM-YUL
SES-AUT
SCA-AEM
MET-EXC
SEN-SER
AJU-REP
OPH-NAN
SYNTHETIC
TURF
SYNTHETIC
TURF
SYNTHETIC
TURF
SYNTHETIC
TURF
AS STREET
TREE
LAG-IND
AS STREET
TREE
LAG-IND
RI RI RI
CY
NEW STREET
LIGHT LOCATION
LANDSCAPE ARCHITECTURAL PLANS FORANDREW AND JULIE STUPIN 3322 VIA LIDO • NEWPORT BEACH, CA 92663DATE:
DRAWN BY:D.P.
5-9-19
© DAVID A. PEDERSEN INC. - LANDSCAPE ARCHITECT EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT & OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO A THIRD PARTY, WITHOUT FIRST OBTAINING THE WRITTEN PERMISSION OF MR. PEDERSEN. IN THE EVENT OF UNAUTHORIZED USE OF THESE PLANS BY ANY THIRD PARTY THE CLIENT AGREES TO HOLD HARMLESS INDEMNIFY AND DEFEND D. PEDERSEN INC. LANDSCAPE ARCHITECT FROM ANY CLAIMS ARISING FROM SUCH UNAUTHORIZED RE-USE.D A V I D A. P E D E R S E N • INC.20271 ACACIA ST., SUITE 120NEWPORT BEACH, CA 92660TEL. (949) 251-8999FAX. (949) 251-0899L A N D S C A P E A R C H I T E C T U R ESHEET NO.
OF -
L-APN: 423-123-12 & 423-123-21LOT 68, TRACT NO. 3357, CITY OF NEWPORT BEACH,COUNTY OF ORANGE34
JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT
A-1.0
7/19/19
2018373-DIMENSIONAL VIEWSSTUPIN RESIDENCE
STUPIN RESIDENCEAMDREW & JULIE STUPINC/O. COASTLINE REALESTATE INVESTMENTS215TH STREETHUNTINGTON BEACHCA 92648CDP
3322 VIA LIDO, NEWPORT BEACH, CA 92663JUSTIN JONHSTON
NO. REVISION DATE
4 AXONOMETRIC - SOUTH 2 AXONOMETRIC - WEST
3 AXONOMETRIC - NORTH 1 AXONOMETRIC - EAST
35
DW T
DW T
UP
NEW WALL -2 x 6 STUDS @ 16" O.C.
NEW WALL -2 x 4 STUDS @ 16" O.C.
WALL W/. STONE VENEER -2 x 6 STUDS @ 16" O.C.
CONCRETE RETAINING WALL -REF. STRUCTURAL
CONCRETE MASONRY WALL -6" CMU U.N.O.
DOUBLE WALL CONSTRUCTION -2 x 4 MIN. STAGGERED
STUD @ 16" O.C.
WINDOW -REFERENCE SCHEDULE
DOOR -REFERENCE SCHEDULE
CABINET -BUILT IN CASEWORK
COLUMN -REF. STRUCTURAL DWGS.
FURNITURE -FOR PRESENTATION PURPOSES ONLY
FIREPLACE -PREFAB GAS-ONLY APPLIANCE
PLUMBING FIXTURE -SINK (AS SELECTED)
PLUMBING FIXTURE -TOILET (AS SELECTED)
PLAN LEGEND
LIGHTING FIXTURE -REFERENCE ELECTRICAL PLANS
FIRE RATED CEILING ASS'Y. REF. DTL. 7/AD-1
INT. FIRE RATED PARTITION REF. DTL. 7/AD-1
EXT. FIRE RATED PARTITION REF. DTL. 5/AD-1
101
1i
?KEYNOTE TAG -REFERENCE KEYNOTE LEGEND THIS SHT.
WINDOW TAG -REFERENCE SHEET A-7.0
DOOR TAG -REFERENCE SHEET A-7.0
1.PROVIDE WHOLE BUILDING MECHANICAL
VENTILATION PER ASHRAE STANDARD 62.2-2016 SECTION
4, WITH EXCEPTION THAT NATURAL VENTILATION
THROUGH DOORS AND WINDOWS IS NOT AN
ACCEPTABLE ALTERNATIVE TO WHOLE-BUILDING
VENTILATION (BEES 152(a), EXCEPTION 5 TO SECTION
152(a)). FOR CONTINUOUS WHOLE-BUILDING
VENTILATION, MIN. REQUIRED RATE OF VENTILATION IS 1
CFM FOR EACH 100 S.F. OF CONDITIONED FLOOR AREA
PLUS 7.5 CFM FOR EACH OCCUPANT (ONE OCCUPANT
PER BEDROOM +1). VENTILATION TO BE PROVIDED BY
EXHAUST AIR, SUPPLY AIR OR COMBINED EXHAUST AND
SUPPLY AIR.
2.PROVIDE IN KITCHEN LOCAL EXHAUST SYSTEM
VENTED TO OUTDOORS WITH RATE = 100 CFM (PART OF
WHOLE-BUILDING VENTILATION REQUIREMENT).
MECHANICAL VENTILATION NOTE:
CALCULATIONS:
UNIT: 7,868 S.F.
(0.03)7,868 S.F. + [7.5 CFM x OCC. (# of BEDS + 1)] =
236.04 + (7.5 x 6) = 281.04 CFM REQ'D.
A-4.11
A-4.1
A-4.0
A-4.0
2
1
2
2
A-5.4
2
A-5.4
1
A-5.4
1
A-5.4
1
A-5.3
1
A-5.3
1
A-5.1
1
A-5.1
2
A-5.3
2
A-5.3
2
A-5.1
2
A-5.1
2
A-5.0
2
A-5.0
2
A-5.2
2
A-5.2
1
A-5.5
1
A-5.5
1
A-5.0
1
A-5.0
2-CAR GARAGE 1
2-CAR GARAGE 2
POWDER
MUD ROOM
FOYER
BUTLER'S
KITCHEN
KITCHEN
DINING ROOM
GREAT ROOM
GAME ROOM
1
A-5.2
1
A-5.2
ELEVATOR
POOL BATH
LOGGIA
PATIO
(COVERED)
(COVERED)
W/C.
STAIRS
SPA
(BY SEP. PERMIT)CLR.21' - 3 3/4"CLR.
21' - 8 3/8"CLR.21' - 0"CLR.
21' - 6 3/8"L.Y.S.B.7' - 6"R.Y.S.B.7' - 6"OCEAN F.Y.S.B.
10' - 0"
F.Y.S.B.
4' - 0"7' - 8 7/8"76' - 9 1/2"9' - 0 1/2"22' - 5"32' - 2 1/2"22' - 2"1' - 11"18' - 4"1' - 11"2' - 8"17' - 1"2' - 8"2' - 3 3/8"64' - 9 3/8"12' - 5 1/2"
52' - 3 1/8"12' - 6 1/4"
19' - 3 1/4"3' - 2 1/8"5' - 2 3/8"19' - 1 1/2"3' - 8"1' - 9 7/8"9' - 10 1/4"2' - 8"7' - 8 7/8"75' - 8"10' - 2"2' - 6"7' - 8"21' - 10 1/2"31' - 11"21' - 10 1/2"9' - 6 3/8"12' - 10 1/4"9' - 6 3/8"1' - 3"8' - 3 3/8"1' - 3"6"1' - 3"3' - 5 1/8"3' - 5 1/8"1' - 3"6"1' - 3"8' - 3 3/8"1' - 3"ENTRY DATUM ENTRY DATUM
1
1
2' - 2 1/2"18' - 0"2' - 2 1/2"5' - 8"4' - 5 7/8"10' - 6 1/4"4' - 5 7/8"5' - 8"2' - 2 1/2"18' - 0"2' - 2 1/2"22' - 5"30' - 10"22' - 5"11 1/8"8' - 8"11 1/8"4' - 4"4' - 4"DN
1' - 3"3' - 5 5/8"
1' - 3"3' - 6 5/8"
1' - 3"6"1' - 3"5' - 10"
1' - 3"6"1' - 3"5' - 10"
12' - 9 1/8"67' - 2 3/8"10' - 0 1/2"
21' - 4 7/8"40' - 3 1/2"3' - 7"1' - 11"
1' - 8"2' - 1"4' - 10 3/4"14' - 7 1/4"5' - 0 3/4"3' - 5 5/8"3' - 2 5/8"1' - 0 3/4"3' - 3"11 3/4"22' - 5"30' - 10"1' - 4 1/2"1' - 11"16' - 9 3/4"2' - 2 1/2"2' - 7 1/4"7' - 8 1/4"9' - 2"6' - 11 5/8"8' - 5 3/4"6' - 11 5/8"1' - 5"28' - 0"1' - 5"1' - 4"9' - 10 1/4"2' - 8"
1' - 4"
1' - 7 1/2"
11' - 4 3/4"1' - 11"
4' - 1 3/4"5' - 3 1/2"3' - 7"1' - 11"
2
2
3
456
7 CLR.3' - 4 1/2"895
10 11
10 11
12
4
6
2 2 CLR.3' - 8 1/2"9
4
5
7
13
13
13
13
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
12
3
54
7
8 10
9 11
12
13
14
15
16
17
1819
20
ABV.
ABV.
ABV.
ABV.ABV.ABV.
ABV.
ABV.
ABV.
ABV.
6
ABV.
R
F.
REF.
14
1' - 6"8' - 9 1/4"4' - 7 7/8"
3 1/8"
CLR.
3' - 0"
7 1/8"
1' - 4 1/8"2' - 3"
5 1/4"
4' - 4 3/4"
7 1/4"
3' - 7 3/8"6' - 4 1/2"3' - 6 3/8"
7 1/4"
4' - 4 3/4"
5 1/4"
1' - 4 1/2"
1' - 9 5/8"CLR.5' - 0 1/8"CLR.
5' - 8 1/2"
1' - 0"
6 5/8"
7' - 0 1/8"4' - 10 3/4"5' - 3 7/8"10 5/8"2' - 8 1/2"25' - 8 3/4"
1' - 0"
1' - 9 5/8"4' - 3 1/8"1' - 6"5' - 0 3/4"6' - 6"3' - 11 1/4"1' - 1 1/2"1' - 5"1' - 6 1/8"2' - 5 5/8"9"9' - 8 3/4"6' - 8 7/8"4' - 0"10 1/4"
2' - 1"4' - 10 3/4"1' - 7 7/8"
CLR.
11' - 0"1' - 11 3/8"5' - 0 3/4"2' - 6 1/2"ISLAND10' - 1"ISLAND
3' - 6"8' - 11 3/8"2' - 1 7/8"10' - 0 1/2"1' - 4 1/2"8' - 10 3/4"1' - 1 1/4"8' - 4 3/4"1' - 1 1/4"8' - 10 3/4"1' - 10"1' - 9 7/8"11 1/8"4' - 4 3/4"9' - 4 3/4"4' - 4 3/4"11 1/8"2' - 1"1' - 2"8"1' - 9 7/8"8' - 11 3/8"2' - 3 7/8"6' - 1 1/2"35' - 4 1/4"1' - 9 7/8"17' - 9 3/4"4' - 3 3/4"ISLAND
14' - 0"ISLAND4' - 6"2' - 8 1/4"4' - 4 3/4"
7 1/4"
13' - 6 1/4"
7 1/4"
4' - 4 3/4"
1' - 7 3/8"
1' - 6 3/8"
SLOPE PER CIVIL
SLOPE PER CIVIL
SLOPE PER CIVIL
SLOPE PER CIVIL
15
16 17
15
16
16
17
16
16
17
16
17 16171617
18 3 5
4 6 5
4 19 6
6
6
20
20
6
5
4
18 19 54
2122
2
213
13
5
5
23
24
2
25252
26
6
5
5
AD-1
18
AD-1
16
AD-1
16
AD-1
22
AD-1
22
6
AD-1
6
AD-1
8
AD-1
8
AD-1
7
AD-1
7
AD-1
7
AD-1
7
AD-1
JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT
A-2.0
7/19/19
201837MAIN LEVEL FLOOR PLANSTUPIN RESIDENCE
STUPIN RESIDENCEAMDREW & JULIE STUPINC/O. COASTLINE REALESTATE INVESTMENTS215TH STREETHUNTINGTON BEACHCA 92648CDP
3322 VIA LIDO, NEWPORT BEACH, CA 92663JUSTIN JONHSTON
STAIRWAY NOTE:
ALL STAIRWAYS SHALL HAVE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1
FOOT CANDLE PER CRC R303.7
KEYNOTE LEGEND
1 VEHICLE - MINIMUM PARKING DIMENSIONS ON PLANS
2 FURNISHINGS - AS SELECTED
3 KITCHEN SINK - AS SELECTED
4 BASE CABINET - BUILT-IN, FINISH AS SEL.
5 COUNTERTOP - AS SELECTED
6 UPPER CABINET - BUILT-IN, FINISH AS SEL.
7 BASE CABINET - BUILT-IN, FINISH AS SEL.
8 BASE CABINET - SINK UNIT, BUILT-IN, FINISH AS SEL.
9 SINK - AS SELECTED (VERIFY COUNTER OR WALL MOUNT FIXTURES W/. OWNER)
10 FIREPLACE - PREFABRICATED, GAS ONLY, 'ASTRIA' GEORGIAN FIREPLACE - SIZE PER PLAN (ANSI Z21.60), 36"
SINGLE SIDED CONFIGURATIONS [DTL. 22/AD-1] (FACTORY BUILT FIREPLACES, CHIMNEYS, AND ALL OTHER
COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING AND MFG'R. INSTALLATION
INSTRUCTIONS. GASEOUS FUEL BURNING PAN MUST BE PERMANENTLY ANCHORED TO THE FIREBOX. FIREPLACE
MUST COMPLY W/. THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES.)
11 EXTERIOR COMBUSTION AIR DUCTS SHALL BE LISTED COMPONENTS OF THE FIREPLACE, AND INSTALLED
ACCORDING TO THE F.P. MFGR'S. INSTR'S. (CBC 2111.13.1) SIDE VENT IN WALL NOT PERMITTED WITHIN 3' OF
PROPERTY LINE. TERMINATION AT TOP OF CHIMNEY.
12 BAR SINK - AS SELECTED
13 FOOTPRINT OF EXISTING STRUCTURE, TO BE REMOVED
14 MAIN SERVICE PANEL, 400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION)
15 DOWNSPOUT - COPPER/ALUMINUM W/. KYNAR FINISH OR EQUIV. - AS SEL. (ARCH. TO APPROVE)
16 OVERFLOW DRAIN - REF. DTL. 11/AD-1
17 DRAIN LINE - IN WALL/FROM ABV. (REF. CIVIL DWGS. & DETAILS)
18
19 TRASH COMPACTOR
20 REFRIGERATOR - VERIFY APPLIANCE W/. OWNER
21 KITCHEN EXHAUST HOOD - PROVIDE VENT TO OUTDOOR W/. MIN. RATE OF 100 CFM - INSTALL & PROVIDE POWER
PER MFGR'S. INSTRS.
22 RANGE - VERIFY APPLIANCE W/. OWNER - PROVIDE HOOD CAPABLE OF 100 CFM MIN. (VERIFY W/. MFGR.)
23 RESIDENTIAL HYDRAULIC ELEVATOR - 'WAUPACA ELEVATOR COMPANY' OR EQUIV., SHAFT SIZE APPX. = 60" X 68"
CLEAR - PROVIDE SHOP DWGS. TO ARCH. PRIOR TO PURCHASE & INSTALLATION
24 STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1
FOOT CANDLE (CBC 1205.4) REF. DTL. 3/AD-1
25 TALL CABINET - BUILT-IN, FINISH AS SEL.
26 WINE RACKS - AS SELECTED - PROVIDE SHOP DWGS. TO ARCH & OWNER
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.)
TYP. U.N.O. ROUNDED TO THE NEAREST 1/8" -CONTACT ARCHITECT IN WRITING FOR ANY
CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
PROJECT NORTHTRUE NORTH
1/4" = 1'-0"1 FIRST FLOOR PLAN
*HERS VERIFICATION REQUIRED-REFERENCE T-24.1
A
ROUGH FRAMING:
ALL EXTERIOR WALLS TO BE FRAMED WITH 2 X 6 STUDS
SECOND AND THIRD FLOOR PLYWOOD TO BE 1-1/8"
ENTIRE EXTERIOR TO BE SHEATHED WITH 1/2" PLYWOOD
NO. REVISION DATE
36
WD D
UP
DN
A-4.11
A-4.1
A-4.0
A-4.0
2
1
2
2
A-5.4
2
A-5.4
1
A-5.4
1
A-5.4
1
A-5.3
1
A-5.3
1
A-5.1
1
A-5.1
2
A-5.3
2
A-5.3
2
A-5.1
2
A-5.1
2
A-5.0
2
A-5.0
2
A-5.2
2
A-5.2
1
A-5.5
1
A-5.5
1
A-5.0
1
A-5.0
MASTER SUITE
GYM / OFFICEBEDROOM #2
W.I.C.
BATH #2
BATH #4
W.I.C.
LAUNDRY
ELEVATOR
BEDROOM #3
W.I.C.
BATH #3
MASTER W.I.C.
1
A-5.2
1
A-5.2
W/C.
STAIRS
W/C.
SHOWER
SHOWER
SHOWER
SEATSEAT OCEAN F.Y.S.B.
10' - 0"S.Y.S.B.7' - 6"S.Y.S.B.7' - 6"F.Y.S.B.
4' - 0"
2' - 3 3/8"52' - 3 1/8"24' - 11 3/4"
2' - 2 3/8"52' - 3 1/8"12' - 6 1/4"12' - 5 1/2"
3' - 9 3/8"9' - 6"2' - 9 5/8"4' - 6 3/4"2' - 8 1/8"3' - 8 3/4"4' - 6 3/4"4' - 6 3/4"2' - 9 5/8"9' - 6"3' - 9 3/8"
2' - 1 7/8"6' - 10"2' - 0 1/8"10' - 2"75' - 8"7' - 8 7/8"22' - 5"30' - 10"22' - 5"5' - 9"10' - 11"5' - 9"5' - 9"10' - 11"5' - 9"8:128:126:12
6:12 3' - 2 1/2"2' - 5 1/2"2' - 5 1/2"4' - 10"2' - 5 1/2"2' - 5 1/2"4' - 10"2' - 5 1/2"2' - 5 1/2"3' - 2 1/2"2' - 1 7/8"8' - 10 1/8"
12' - 9 1/8"60' - 5 3/8"16' - 9 1/2"
3' - 11 7/8"2' - 0 1/8"12' - 4 5/8"6' - 0 3/4"2' - 0 7/8"2' - 0 3/8"2' - 3 3/4"5' - 7"2' - 7 1/4"4' - 10 1/2"11' - 11"
12' - 9 1/8"21' - 4 7/8"39' - 0 1/2"
10' - 7 3/8"2' - 1 7/8"3' - 9 3/8"9' - 6"2' - 9 5/8"3' - 7 7/8"1' - 8"2' - 6"7' - 8"W/C.
MASTER BATH
W/C.7' - 8 7/8"78' - 2"7' - 8"22' - 5"34' - 1"18' - 5"3' - 3"1' - 4"3' - 7 1/4"9' - 5 1/2"
1' - 4"3' - 7 1/4"3' - 3"1' - 5"28' - 0"1' - 5"3' - 6"7' - 8 1/2"7' - 8 1/2"3' - 6"3' - 3 1/4"5' - 7 3/4"
6' - 10 1/2"5' - 7 3/4"9:128:128:12
8:121
2
3
R @ 0' -7 3/4"16
4
5
6
2
7CLR.3' - 0"8
CLR.3' - 0"8
8
CLR.
2' - 6"
945
2
10 11 CLR.3' - 9 3/4"8
12
2
9134CLR.4' - 5 7/8"8
7
SEATSHOWER
7
14 1515
5
4
16
17
17
1718
1 5/8"
19
20
20
197:1219
19
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
26
21 22 23
24 25
ABV.
272829303132
33
34
35
1
2
3
4
5
6
7
8
9
10
11
12 CLR.9' - 9 3/4"CLR.9' - 9 3/4"3' - 1 1/4"2' - 1 1/4"3' - 8 3/4"4' - 1 1/8"1' - 7 5/8"2' - 4 1/8"1' - 10 5/8"5' - 9"1' - 0 5/8"3' - 4 3/8"2' - 0 3/8"3' - 3 5/8"4' - 5"5' - 4"4' - 5"3' - 9"7 3/4"5' - 5"2' - 1 1/8"3' - 7 5/8"4' - 3 1/2"1' - 9"3' - 6 3/4"CLR.5' - 0"CLR.
5' - 8 1/2"3' - 4"2' - 8"11 1/4"
15' - 6 3/4"4' - 1 1/4"2' - 2 1/4"4' - 6 3/4"12' - 4 5/8"3' - 9 5/8"2' - 3 1/8"2' - 0 1/4"2' - 6 1/2"1' - 10 1/4"5' - 7"2' - 7 1/4"4' - 6 1/4"
2' - 10 1/2"3' - 7 1/4"6 3/8"2' - 0 5/8"3' - 5"5' - 0 3/4"2' - 2 1/4"3' - 7 1/4"30' - 5 5/8"10 5/8"1' - 4 1/8"4' - 2 1/2"4' - 0 3/4"6' - 1 3/4"4' - 0 3/4"4' - 8 7/8"3 3/4"3' - 5 5/8"3' - 6 3/4"3' - 7 3/4"1' - 4 1/2"CLR.28' - 0"1' - 11 1/4"15' - 6 3/4"4' - 1 1/4"2' - 11 5/8"3' - 10 3/4"5' - 7 1/4"3' - 0 3/4"16' - 1"6' - 8"5' - 10"3' - 1 1/4"3' - 9 5/8"2' - 3 1/8"
6 1/8"
1' - 6 3/4"
4' - 6 3/4"2' - 2 1/2"7' - 4"2' - 4"4' - 1 1/4"
6' - 10 3/4"6' - 1 1/4"4' - 7 1/4"6"
1' - 11 1/2"
20' - 6 5/8"
4' - 7 1/4"
(OPEN TO ABV. & BLW.)
FOYER (BLW.)1' - 10 5/8"3' - 4"10 1/8"6"9' - 7 7/8"1' - 5 1/4"8' - 2 1/4"1' - 5 1/4"2' - 6 5/8"4' - 7 3/4"3' - 5 1/8"3' - 5 3/8"2' - 4 1/8"9 5 4
20
20 20
20
21
22
21
21
CLR.
30" MIN.
CLR.
30" MIN.
CLR.
30" MIN.
CLR.
30" MIN.
9 54
7
1
2
4
5 94
5
13
2
23
24
6 259
AD-1
22
14
AD-1
15
AD-1
4
AD-1
6 " M A X .
NEW WALL -2 x 6 STUDS @ 16" O.C.
NEW WALL -2 x 4 STUDS @ 16" O.C.
WALL W/. STONE VENEER -2 x 6 STUDS @ 16" O.C.
CONCRETE RETAINING WALL -REF. STRUCTURAL
CONCRETE MASONRY WALL -6" CMU U.N.O.
DOUBLE WALL CONSTRUCTION -2 x 4 MIN. STAGGERED
STUD @ 16" O.C.
WINDOW -REFERENCE SCHEDULE
DOOR -REFERENCE SCHEDULE
CABINET -BUILT IN CASEWORK
COLUMN -REF. STRUCTURAL DWGS.
FURNITURE -FOR PRESENTATION PURPOSES ONLY
FIREPLACE -PREFAB GAS-ONLY APPLIANCE
PLUMBING FIXTURE -SINK (AS SELECTED)
PLUMBING FIXTURE -TOILET (AS SELECTED)
PLAN LEGEND
LIGHTING FIXTURE -REFERENCE ELECTRICAL PLANS
FIRE RATED CEILING ASS'Y. REF. DTL. 7/AD-1
INT. FIRE RATED PARTITION REF. DTL. 7/AD-1
EXT. FIRE RATED PARTITION REF. DTL. 5/AD-1
101
1i
?KEYNOTE TAG -REFERENCE KEYNOTE LEGEND THIS SHT.
WINDOW TAG -REFERENCE SHEET A-7.0
DOOR TAG -REFERENCE SHEET A-7.0
1.PROVIDE WHOLE BUILDING MECHANICAL
VENTILATION PER ASHRAE STANDARD 62.2-2016 SECTION
4, WITH EXCEPTION THAT NATURAL VENTILATION
THROUGH DOORS AND WINDOWS IS NOT AN
ACCEPTABLE ALTERNATIVE TO WHOLE-BUILDING
VENTILATION (BEES 152(a), EXCEPTION 5 TO SECTION
152(a)). FOR CONTINUOUS WHOLE-BUILDING
VENTILATION, MIN. REQUIRED RATE OF VENTILATION IS 1
CFM FOR EACH 100 S.F. OF CONDITIONED FLOOR AREA
PLUS 7.5 CFM FOR EACH OCCUPANT (ONE OCCUPANT
PER BEDROOM +1). VENTILATION TO BE PROVIDED BY
EXHAUST AIR, SUPPLY AIR OR COMBINED EXHAUST AND
SUPPLY AIR.
2.PROVIDE IN KITCHEN LOCAL EXHAUST SYSTEM
VENTED TO OUTDOORS WITH RATE = 100 CFM (PART OF
WHOLE-BUILDING VENTILATION REQUIREMENT).
MECHANICAL VENTILATION NOTE:
CALCULATIONS:
UNIT: 7,868 S.F.
(0.03)7,868 S.F. + [7.5 CFM x OCC. (# of BEDS + 1)] =
236.04 + (7.5 x 6) = 281.04 CFM REQ'D.
JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT
A-2.1
7/19/19
201837SECOND LEVEL FLOOR PLANSTUPIN RESIDENCE
STUPIN RESIDENCEAMDREW & JULIE STUPINC/O. COASTLINE REALESTATE INVESTMENTS215TH STREETHUNTINGTON BEACHCA 92648CDP
3322 VIA LIDO, NEWPORT BEACH, CA 92663JUSTIN JONHSTON
NO. REVISION DATE
PROJECT NORTHTRUE NORTH
1/4" = 1'-0"1 SECOND FLOOR PLAN
STAIRWAY NOTE:
ALL STAIRWAYS SHALL HAVE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1
FOOT CANDLE PER CRC R303.7
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.)
TYP. U.N.O. ROUNDED TO THE NEAREST 1/8" -CONTACT ARCHITECT IN WRITING FOR ANY
CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
*HERS VERIFICATION REQUIRED-REFERENCE T-24.1
ROUGH FRAMING:
ALL EXTERIOR WALLS TO BE FRAMED WITH 2 X 6 STUDS
SECOND AND THIRD FLOOR PLYWOOD TO BE 1-1/8"
ENTIRE EXTERIOR TO BE SHEATHED WITH 1/2" PLYWOOD
A
KEYNOTE LEGEND
1 WORKOUT/GYM EQUIPMENT
2 FURNISHINGS - AS SELECTED
3 STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1
FOOT CANDLE (CBC 1205.4) REF. DTL. 3/AD-1
4 COUNTERTOP - AS SELECTED
5 BASE CABINET - BUILT-IN, FINISH AS SEL.
6 UPPER CABINET - BUILT-IN, FINISH AS SEL.
7 SHELF AND POLE - BUILT IN, FINISH AS SEL.
8 BASE CABINET - BUILT-IN, FINISH AS SEL.
9 SINK - AS SELECTED (VERIFY COUNTER OR WALL MOUNT FIXTURES W/. OWNER)
10 FIREPLACE - PREFABRICATED, GAS ONLY, 'ASTRIA' GEORGIAN FIREPLACE - SIZE PER PLAN (ANSI Z21.60), 36"
SINGLE SIDED CONFIGURATIONS [DTL. 22/AD-1] (FACTORY BUILT FIREPLACES, CHIMNEYS, AND ALL OTHER
COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING AND MFG'R. INSTALLATION
INSTRUCTIONS. GASEOUS FUEL BURNING PAN MUST BE PERMANENTLY ANCHORED TO THE FIREBOX. FIREPLACE
MUST COMPLY W/. THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES.)
11 EXTERIOR COMBUSTION AIR DUCTS SHALL BE LISTED COMPONENTS OF THE FIREPLACE, AND INSTALLED
ACCORDING TO THE F.P. MFGR'S. INSTR'S. (CBC 2111.13.1) SIDE VENT IN WALL NOT PERMITTED WITHIN 3' OF
PROPERTY LINE. TERMINATION AT TOP OF CHIMNEY.
12 BATHTUB - FREE-STANDING, AS SELECTED (VERIFY LOC'N. OF FIXTURES W/. OWNER)
13 BASE CABINET - SINK UNIT, BUILT-IN, FINISH AS SEL.
14 WASHER AND/OR DRYER - PROVIDE HOOK-UPS, POWER, INSTALL PAN & DRAIN UNDER WASHER (TYP.) - G.C. TO
VERIFY LOC'N. & SIZE & DRYER VENT 14' MAX. LENGTH (CMC 504.3.2) PROVIDE GAS STUB-OUT
15 DRYER - PROVIDE 4" MIN. DIA. DUCT, 14' MAX. LENGTH INCLUDING (2) 90 DEGREE ELBOWS, DEDUCT TWO(2) FEET
FOR EACH 90 DEGREE ELBOW IN EXCESS OF TWO(2) (CMC 504.3.2)
16 COLLECTOR TO MATCH DOWNSPOUT AND GUTTER MAT., REF. AMT. SCHED. A/A-4.0 - ARCH. TOP APPV.
17 DOWNSPOUT - COPPER/ALUMINUM W/. KYNAR FINISH OR EQUIV. - AS SEL. (ARCH. TO APPROVE)
18 GUTTER - PER MAT. SCHED. A/A-4.0, SHAPE AS SEL. - PROVIDE SHOP DWGS. TO ARCH.
19 FOOTPRINT OF EXISTING STRUCTURE, TO BE REMOVED
20 PROPERTY LINE
21 SHOWER - HOT-MOP PAN, PROVIDE TILE W/. CEMENT BACKING MIN. 72" HIGH; NET AREA 7.1 S.F. MIN.; 30" DIA.
CIRCLE MIN., REF. DTL. 19/AD-1
22 MASTER SHOWER - PROVIDE RAIN DOME SHOWER HEAD, 2 FIXED HEADS & 1 HAND SHOWER
23 INTERIOR GUARDRAIL - MIN. 42" HIGH - MATERIAL AS SELECTED, <4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
24 HANDRAIL - 34" - 38" ABOVE STAIR NOSING (36" U.N.O.) - MATERIAL AS SELECTED, REF. DTLS. 2, 4/AD-1
25 RESIDENTIAL HYDRAULIC ELEVATOR - 'WAUPACA ELEVATOR COMPANY' OR EQUIV., SHAFT SIZE APPX. = 60" X 68"
CLEAR - PROVIDE SHOP DWGS. TO ARCH. PRIOR TO PURCHASE & INSTALLATION
37
T
DN
DN
DN
A-4.11
A-4.1
A-4.0
A-4.0
2
1
2
2
A-5.4
2
A-5.4
1
A-5.4
1
A-5.4
1
A-5.3
1
A-5.3
1
A-5.1
1
A-5.1
2
A-5.3
2
A-5.3
2
A-5.1
2
A-5.1
2
A-5.0
2
A-5.0
2
A-5.2
2
A-5.2
1
A-5.5
1
A-5.5
1
A-5.0
1
A-5.0
FAMILY ROOM
1
A-5.2
1
A-5.2
BATH #5
W.I.C.
BEDROOM #5
STAIRS
ELEVATOR
BATH #6
OCEAN F.Y.S.B.
10' - 0"S.Y.S.B.7' - 6"S.Y.S.B.7' - 6"F.Y.S.B.
4' - 0"
18' - 8 3/4"19' - 9 1/4"41' - 0 1/4"
16' - 5 3/8"1' - 9 5/8"8' - 1"8' - 1"1' - 9 5/8"16' - 0 1/2"24' - 11 3/4"
34' - 2"21' - 11 3/4"33' - 10 1/4"
12' - 9 1/8"21' - 4 7/8"2' - 6 5/8"9' - 9 1/2"2' - 6 1/8"3' - 3 7/8"3' - 9 5/8"14' - 5 1/2"2' - 7 1/4"16' - 9 1/2"9' - 1 3/8"75' - 2"9' - 3 1/2"9' - 10"5' - 7 1/4"6' - 9"3' - 6 3/4"5' - 4 7/8"20' - 9 1/8"7' - 2 1/2"3' - 11 1/2"4' - 4 3/8"7' - 8 5/8"F.O.S. OF
WALL BLW.
THE ROOF
9' - 1 3/8"9' - 10"9' - 7 3/4"33' - 10 1/4"21' - 10"9' - 3 1/2"15' - 5 3/4"4' - 0"30' - 11"2' - 11 1/4"5' - 9 1/2"16' - 0 1/2"1 2
3
3
3 1/4"
8' - 0"
3 1/2"
7' - 7 1/2"1/2"6' - 0 1/2"27' - 9 1/4"
2 1/8"
8' - 0"
10 1/8"
13' - 3"27' - 9 1/4"3' - 8"7' - 8"43
5
R @ 0' -6"3
6
7
R @ 0' -6"3
5
R @ 0' -7 3/4"16
5
8
9
10
11
3
7
CLR.
2' - 9"SEATSHOWER
5' - 8 3/4"10' - 0"1' - 6"7' - 6"1' - 6"10' - 0"4' - 0"3' - 4 1/2"10:1210:1210:1210:121.5:121.5:12
4:124:12
4:1212:12
12:12
12:12
12:1210:128:128:128:128:128:128:1210:129:129:121.5:12
10:12 9:129:1210:12
12
8
10
3
13
13
13
13
13 13
13
13
13
13
13
14
14
14
14
14
15
15
16
16
16
16
37
38
40
41
42
43
44
45
38 39 40
412' - 1"3' - 8 1/2"2' - 11 1/4"44 45
474849
4243
13
14
15 CLR.3' - 4 3/8"(OPEN TO BLW.)
FOYER (BLW.)14' - 5 3/4"4' - 9 1/8"2' - 1 7/8"3' - 4 3/4"2' - 11 1/8"2' - 11 1/8"20' - 9 1/8"3' - 9 1/2"3' - 5"2' - 9 1/8"4' - 10 7/8"7' - 10 3/8"1 3/4"CLR.4' - 10 1/8"CLR.
5' - 8 1/2"
5' - 4 3/8"2' - 2 7/8"3' - 0 5/8"4' - 3 1/4"4' - 9 1/2"7' - 1 1/2"
7' - 8"
5' - 4 3/4"4' - 10 3/8"4' - 2 1/8"4' - 4 1/8"
8 1/2"5' - 4 3/4"
F.O.S. OF
WALL BLW.
THE ROOF
F.O.S. OF
WALL BLW.
THE ROOF
F.O.S. OF
WALL BLW.
THE ROOF
F.O.S. OF
WALL BLW.
THE ROOF
3
17
18
19
13
AD-1
4
AD-1
AD-1
22
9
AD-1
CLR.
30" MIN.
12
8
10
NEW WALL -2 x 6 STUDS @ 16" O.C.
NEW WALL -2 x 4 STUDS @ 16" O.C.
WALL W/. STONE VENEER -2 x 6 STUDS @ 16" O.C.
CONCRETE RETAINING WALL -REF. STRUCTURAL
CONCRETE MASONRY WALL -6" CMU U.N.O.
DOUBLE WALL CONSTRUCTION -2 x 4 MIN. STAGGERED
STUD @ 16" O.C.
WINDOW -REFERENCE SCHEDULE
DOOR -REFERENCE SCHEDULE
CABINET -BUILT IN CASEWORK
COLUMN -REF. STRUCTURAL DWGS.
FURNITURE -FOR PRESENTATION PURPOSES ONLY
FIREPLACE -PREFAB GAS-ONLY APPLIANCE
PLUMBING FIXTURE -SINK (AS SELECTED)
PLUMBING FIXTURE -TOILET (AS SELECTED)
PLAN LEGEND
LIGHTING FIXTURE -REFERENCE ELECTRICAL PLANS
FIRE RATED CEILING ASS'Y. REF. DTL. 7/AD-1
INT. FIRE RATED PARTITION REF. DTL. 7/AD-1
EXT. FIRE RATED PARTITION REF. DTL. 5/AD-1
101
1i
?KEYNOTE TAG -REFERENCE KEYNOTE LEGEND THIS SHT.
WINDOW TAG -REFERENCE SHEET A-7.0
DOOR TAG -REFERENCE SHEET A-7.0
1.PROVIDE WHOLE BUILDING MECHANICAL
VENTILATION PER ASHRAE STANDARD 62.2-2016 SECTION
4, WITH EXCEPTION THAT NATURAL VENTILATION
THROUGH DOORS AND WINDOWS IS NOT AN
ACCEPTABLE ALTERNATIVE TO WHOLE-BUILDING
VENTILATION (BEES 152(a), EXCEPTION 5 TO SECTION
152(a)). FOR CONTINUOUS WHOLE-BUILDING
VENTILATION, MIN. REQUIRED RATE OF VENTILATION IS 1
CFM FOR EACH 100 S.F. OF CONDITIONED FLOOR AREA
PLUS 7.5 CFM FOR EACH OCCUPANT (ONE OCCUPANT
PER BEDROOM +1). VENTILATION TO BE PROVIDED BY
EXHAUST AIR, SUPPLY AIR OR COMBINED EXHAUST AND
SUPPLY AIR.
2.PROVIDE IN KITCHEN LOCAL EXHAUST SYSTEM
VENTED TO OUTDOORS WITH RATE = 100 CFM (PART OF
WHOLE-BUILDING VENTILATION REQUIREMENT).
MECHANICAL VENTILATION NOTE:
CALCULATIONS:
UNIT: 7,868 S.F.
(0.03)7,868 S.F. + [7.5 CFM x OCC. (# of BEDS + 1)] =
236.04 + (7.5 x 6) = 281.04 CFM REQ'D.
JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT
A-2.2
7/19/19
201837THIRD LEVEL FLOOR PLANSTUPIN RESIDENCE
STUPIN RESIDENCEAMDREW & JULIE STUPINC/O. COASTLINE REALESTATE INVESTMENTS215TH STREETHUNTINGTON BEACHCA 92648CDP
3322 VIA LIDO, NEWPORT BEACH, CA 92663JUSTIN JONHSTON
NO. REVISION DATE
PROJECT NORTHTRUE NORTH
1/4" = 1'-0"1 THIRD FLOOR PLAN
STAIRWAY NOTE:
ALL STAIRWAYS SHALL HAVE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1
FOOT CANDLE PER CRC R303.7
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.)
TYP. U.N.O. ROUNDED TO THE NEAREST 1/8" -CONTACT ARCHITECT IN WRITING FOR ANY
CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
*HERS VERIFICATION REQUIRED-REFERENCE T-24.1
ROUGH FRAMING:
ALL EXTERIOR WALLS TO BE FRAMED WITH 2 X 6 STUDS
SECOND AND THIRD FLOOR PLYWOOD TO BE 1-1/8"
ENTIRE EXTERIOR TO BE SHEATHED WITH 1/2" PLYWOOD
A
KEYNOTE LEGEND
1 FIREPLACE - PREFABRICATED, GAS ONLY, 'ASTRIA' GEORGIAN FIREPLACE - SIZE PER PLAN (ANSI Z21.60), 36" SINGLE
SIDED CONFIGURATIONS [DTL. 22/AD-1] (FACTORY BUILT FIREPLACES, CHIMNEYS, AND ALL OTHER COMPONENTS
SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING AND MFG'R. INSTALLATION INSTRUCTIONS.
GASEOUS FUEL BURNING PAN MUST BE PERMANENTLY ANCHORED TO THE FIREBOX. FIREPLACE MUST COMPLY W/.
THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES.)
2 EXTERIOR COMBUSTION AIR DUCTS SHALL BE LISTED COMPONENTS OF THE FIREPLACE, AND INSTALLED
ACCORDING TO THE F.P. MFGR'S. INSTR'S. (CBC 2111.13.1) SIDE VENT IN WALL NOT PERMITTED WITHIN 3' OF
PROPERTY LINE. TERMINATION AT TOP OF CHIMNEY.
3 FURNISHINGS - AS SELECTED
4 PALOFORM, ROBATA 72" CONCRETE FIRE PIT - INSTALL PER MFRG. SPECS & GUIDELINE (PROVIDE GAS & ELEC AS
REQ'D.)
5 STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1
FOOT CANDLE (CBC 1205.4) REF. DTL. 3/AD-1
6 BATHTUB - FREE-STANDING, AS SELECTED (VERIFY LOC'N. OF FIXTURES W/. OWNER)
7 BASE CABINET - BUILT-IN, FINISH AS SEL.
8 BASE CABINET - BUILT-IN, FINISH AS SEL.
9 BAR SINK - AS SELECTED
10 COUNTERTOP - AS SELECTED
11 UPPER CABINET - BUILT-IN, FINISH AS SEL.
12 SINK - AS SELECTED (VERIFY COUNTER OR WALL MOUNT FIXTURES W/. OWNER)
13 SLATE ROOFING. - REF. MATERIAL SCHEDULE SHT. A-4.0
14 ROOF - STANDING SEAM METAL W/. KYNAR FINISH - COLOR AS SELECTED
15 PROPERTY LINE
16 FOOTPRINT OF EXISTING STRUCTURE, TO BE REMOVED
17 SHELF AND POLE - BUILT IN, FINISH AS SEL.
18 HANDRAIL - 34" - 38" ABOVE STAIR NOSING (36" U.N.O.) - MATERIAL AS SELECTED, REF. DTLS. 2, 4/AD-1
19 INTERIOR GUARDRAIL - MIN. 42" HIGH - MATERIAL AS SELECTED, <4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
38
UP
UP
ROOF VENTILATION NOTES: (CRC R806)
1.ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE
UNDERSIDE OF ROOF RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE BY VENTILATING
OPENINGS PROTECTED AGAINST THE ENTRANCE OF RAIN OR SNOW. VENTILATION OPENINGS SHALL HAVE AT LEAST
DIM. OF 1/16" MIN. AND 1/4" MAX. VENTILATION OPENINGS HAVING A LEAST DIMENSION LARGER THAN 1/4" SHALL BE
PROVIDED W/. CORROSION-RESISTANT WIRE CLOTH SCREENING, HARDWARE CLOTH, OR SIMILAR MATERIAL WITH
OPENINGS HAVING A LEAST DIM. OF 1/16" MIN. AND 1/4" MAX. OPENINGS IN ROOF FRAMING MEMBERS SHALL
CONFORM TO THE REQ'TS. OF CRC R802.7. REQUIRED VENTILATION OPENINGS SHALL OPEN DIRECTLY TO THE
OUTSIDE AIR.
2. THE NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1/150 OF THE AREA OF THE SPACE VENTILATED. THE
NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1/300 IF ONE OR MORE OF THE FOLLOWING ARE MET; 1. IN
CLIMATE ZONES 14 & 16, A CLASS I OR II VAPOR RETARDER IS INSTALLED ON THE WARM-IN-WINTER SIDE OF THE
CEILING. 2. AT LEAST 40% AND MORE THAN 50% OF THE REQUIRED VENTILATING ARE IS PROVIDED BY VENTILATORS
LOCATED IN THE UPPER PORTION OF THE ATTIC OR RAFTER SPACE. UPPER VENTILATORS SHALL BE LOCATED NO
MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE, MEASURED VERTICALLY, WITH THE
BALANCE OF TEH REQUIRED VANTILATION PROVIDED BY EAVE OR CORNICE VENTS. WHERE THE LOCATION OF WALL
OR ROOF FRAMING MEMBERS CONFLICTS WITH THE INSTALLATION OF UPPER VENTILATORS, INSTALLATION MORE
THAN 3 FEET BELOW THE RIDGE OR HIGHEST OF THE SPACE SHALL BE PERMITTED.
3. WHERE EAVE OR CORNICE VENTS ARE INSTALLED, INSULATION SHALL NOT BLOCK THE FREE FLOW OF AIR. A
MIN. OF A 1" SPACE SHALL BE PROVIDED BETWEEN THE INSULATION AND THE ROOF SHT'G. AND AT THE LOCATION
OF THE VENT.
4. VENTILATORS SHALL BE INSTALLED IN ACCORDANCE WITH MFR'G.'S INSTALLATION INSTRUCTIONS. INSTALLATION
OF VENTILATORS IN ROOF SYSTEMS SHALL BE IN ACCORDANCE W/. THE REQ'TS. OF SECTION R903. INSTALLATION
OF VENTILATORS IN WALL SYSTEMS SHALL BE IN ACCORDANCE W/. THE REQ'TS. OF SECTION R703.1.
5. UNVENTED ATTIC ASSEMBLIES (SPACES BETWEEN THE CEILING JOISTS OF THE TOP STORY AND THE ROOF
RAFTERS) AND UNVENTED ENCLOSED RAFTER ASSEMBLIES (SPACES BETWEEN CEILINGS THAT ARE APPLIED
DIRECTLY TO THE UNDERSIDE OF ROOF FRAMING MEMBER/RAFTERS AND THE STRUCTURAL ROOF SHT'G. AT THE
TOP OF THE ROOF FRAMING MEMBERS/RAFTERS) SHALL BE PERMITTED IF ALL OF THE FOLLOWING CONDITIONS ARE
MET: 1. THE UNVENTED ATTIC SPACE IS COMPLETELY CONTAINED WITHIN THE BUILDING THERMAL ENVELOPE. 2. NO
INTERIOR CLASS I VAPOR RETARDERS ARE INSTALLED ON THE CEILING SIDE (ATTIC FLOOR) OF THE UNVENTED
ATTIC ASSEMBLY OR ON THE CEILING SIDE OF THE UNVENTED ENCLOSED RAFTER ASEEMBLY. 3. WHERE WOOD
SHINGLES OF SHAKES ARE USED, A MIN. 1/4" VENTED AIR SPACE SEPARATES THE SHINGLES OR SHAKES AND THE
ROOFING UNDERLAYMENT ABOVE THE STRUCTURAL SHT'G. 4. IN CALIFORNIA CLIMATE ZONES 14 & 16, ANY AIR-
IMPERMEABLE INSULATION SHALL BE A CLASS II VAPOR RETARDER, OR SHALL HAVE A CLASS III VAPOR RETARDER
COATING OR COVERING IN DIRECT CONTACT W/. THE UNDERSIDE OF THE INSULATION (SEE TITLE 24, PART 6, FIG.
100.1-A) 5. EITHER ITEMS 5.1, 5.2 OR 5.3 SHALL BE MET, DEPENDING ON THE AIR PERMEABILITY OF THE INSULATION
DIRECTLY UNDER THE STRUCTURAL ROOF SHT'G. (NO INSULATION SHALL BE REQ'D. WHEN ROOF TILES, WOOD
SHINGLES OR WOOD SHAKES, OR ANY OTHER ROOFING SYSTEM USING BATTENS AND NO CONT. UNDERLAYMENT IS
INSTALLED. A CONT. LAYER SHALL BE CONSIDERED TO EXIST IF SHT'G., ROOFING PAPER OR ANY CONT. LAYER
WHICH HAS A PERM RATE OF NO MORE THAN ONE PERM UNDER THE DRY CUP METHOD.); 5.1. AIR-IMPERMEABLE
INSULATION ONLY. INSULATION SHALL BE APPLIED IN DIRECT CONTACT W/. THE UNDERSIDE OF THE STRUCTURAL
ROOF SHT'G. 5.2. AIR-PERMEABLE INSULATION ONLY. IN ADDITION TO THE AIR-PERMEABLE INSULATION INSTALLED
DIRECTLY BELOW THE STRUCTURAL SHT'G., RIDGE BOARD OR SHEET INSULATION W/. AN R-VALUE OR R-4 SHALL BE
INSTALLED DIRECTLY ABOVE THE STRUCTURAL ROOF SHT'G. FOR CONDENSATION CONTROL. 5.3. AIR-IMPERMEABLE
AND AIR-PERMEABLE INSULATION. THE AIR-IMPERMEABLE INSULATION SHALL BE APPLIED IN DIRECT CONTACT W/.
THE UNDERSIDE OF THE STRUCTURAL ROOF SHT'G. FOR CONDENSATION CONTROL. THE AIR-PERMEABLE
INSULATION SHALL BE INSTALLED DIRECTLY UNDER THE AIR-PERMEABLE INSULATION. 5.4. WHERE PREFORMED
INSULATION BOARD IS USED AS THE AIR IMPERMEABLE INSULATION LAYER, IT SHALL BE SEALED AT THE PERIMETER
OF EACH INDIVIDUAL SHEET INTERIOR SURFACE TO FORM A CONT. LAYER.
2x ROOF RAFTER
(PER STRUCT.)
INTERIOR FINISH (PER
PLANS, WHERE OCCURS)*
AIR-PERMEABLE
INSULATION (PER PLANS &
T24), TO BE IN DIRECT
CONTACT WITH THE UNDER
SIDE OF THE STRUCTURAL
ROOF SHEATHING FOR
UNVENTED ASSEMBLY IN
CLIMATE ZONE 6-15
HEADLAP
MIN. 2 LAYERS 15#
ROOF FELTS (FOR
SLOPES <3:12
PROVIDE AN
APPROVED SEALED
UNDERLAYMENT -
ARCH. & OWNER TO
APPV.)
1/2" CDX PLYWD. SHT'G.
MIN. (REF. STRUCT)
SLATE TILES AT THE EAVES OR CORNICE LINE SHALL BE
DOUBLED FOR UNDER-EAVES AT FIRST EXPOSED COURSE.
UNDER-EAVE SLATE SHALL BE APPX. 3" LONGER THAN
EXPOSURE OF FIRST COURSE.
SLATE TILES SHALL PROJECT 2" AT THE EAVES AND 1" AT
GABLE ENDS.
NAILS IN SLATES OVERLAPPING SHEET METALWORK SHALL
NOT PUNCTURE THE SHEET METAL. EXPOSED NAILS ARE
PERMISSIBLE ONLY IN TOP COURSES WHERE UNAVOIDABLE.
EXPOSED NAIL HEADS SHALL BE COVERED WITH ELASTIC
CEMENT.
HIP SLATES AND RIDGE SLATES SHALL BE LAID IN ELASTIC
CEMENT, SPREAD THICKLY OVER UNEXPOSED SURFACE OF
UNDER COURSES OF SLATE, NAILED SECURELY IN PLACE AND
POINTED WITH ELASTIC CEMENT.
MINIMUM (2) COPPER NAILS OF
SUFFICIENT LENGTH TO
PENETRATE THE
ROOF DECKING AT LEAST 3/4" OR
THROUGH THE DECKING
THICKNESS,
WHICHEVER IS LESS
MIN. HEADLAP :
4:12 < SLOPE < 8:12 = 4"
8:12 < SLOPE < 20:12 = 3"
SLOPE > 20:12 = 2"
12
PER PLAN
SLOPE
GENERAL NOTES:
4.
3.
2.
1.
REF. CBC 1507.7
FLASHING & COUNTERFLASHING. SHALL BE SHT. MTL. MIN.
UNCOATED 0.0179" THK. ZINC COATED G90. VALLEY FLSH'G.
MIN. 15" WIDE
5.
SLATE SHINGLES SHALL COMPLY WITH ASTM C4066.
*UNVENTED ENCLOSED RAFTER ASSEMBLY NOTE:
NO INTERIOR CLASS I VAPOR RETARDER SHALL BE
INSTALLED ON THE CEILING SIDE (ATTIC FLOOR) OF THE
UNVENTED ATIIC ASSEMBLY OR ON THE CEILING SIDE OF
THE UNVENTED ENCLOSED ROOF FRAMING ASSEMBLY.
CONT. BUILT-UP FASCIA
& SHDW. BD. -ARCH TO
APPV. SIZE PRIOR TO
CUTTING ROOF
RAFTERS
COPPER GUTTER AS SEL.
ROOFING PER PLAN &
MAT. SCHED. O/.
ROOFING FELT (MIN. 2
LAYERS 15#)
2x ROOF RAFTERS PER
STRUCT.
ROOF SHT'G PER STRUCT.
EXTERIOR FINISH PER
PLANS & MAT. SCHED.
COPPER DRIP EDGE (TYP.)
2X SOLID BLK'G.
1x6 T&G SOFFIT
PANELS -PAINT & SEAL
(COLOR AS SEL.)
PROVIDE VENTS FOR
ATTIC VENTILATION PER
CRC R806 AS NEEDED9 1/4"1 1/2"3/4"5 1/2"3 3/4"OVERHANG PER PLANS
1/4"9 1/4"9 1/4"9 1/4"2X SOFFIT FRM'G
TYP. REVEAL -COORD.
W/. EAVES RATED
MIN. 24" TO PL.
FILLED REGION INDICATES ATTIC SPACE-REF. ATTIC
VENTILATION CALCS.
ROOF PLAN LEGEND
1x T&G SOFFIT O/. TYVEK (OR EQUIV.)
PAINT (ARCH. TO APPV.)
INTERIOR FINISH, PER
PLAN
(WHERE OCCURS)
'TYVEK' OR EQ. BLDG. WRAP
CDX PLYWD. SHT'G. (PER STRUCT'L.)
THERMAL BATT INSUL'N.
CAULK & SEAL
ROOFING MATERIAL (REF.
PLANS)
O/. 30# ROOF FELT & CDX
PLYWD.
ROOF SHT'G. (PER STRUCT'L.)
CONT. BUILT-UP FASCIA & SHDW.
BD. -ARCH. TO APPV. SIZE PRIOR
TO CUTTING ROOF RAFTERS
CAULK & SEAL
BASE FLASHING
EAVE FLASHING W/. DRIP (BY
ROOFING MFGR.) TO MATCH
ROOF
EXTERIOR FINISH -REF.
PLANS & MAT. SCHED.
2x BLK'G.1"OVERHANG PER PLANS
2x SOFFIT FRM'G.
MIN. 24" TO PL.
2x ROOF RAFTER
(PER STRUCT.)
*INTERIOR FINISH
(PER PLANS, AS OCCURS)
AIR-PERMEABLE INSULATION
(PER PLANS & T24), TO BE IN
DIRECT CONTACT WITH THE
UNDER SIDE OF THE
STRUCTURAL ROOF SHEATHING
FOR UNVENTED ASSEMBLY
MIN. 30# ROOF FELT-(2)
LAYERS GAF VERSASHIELD
UNDERLAYMENT
15/32" CDX PLYWD. SHT'G.
MIN. (REF. STRUCT)
FASTENERS PER
MFGR. INSTRUCTIONS
12
SLOPE PER PLAN
STANDING SEAM METAL
(ZINC OR EQUIV.) -REF.
MAT. SCHED. A/A-5,
CLASS 'A' ASSY.
TYP.6" - 10"6" MIN.
DOUBLE FOLD
3/4" LOCK, ALT. METHOD
CLEATS @ 18" O.C. MAX.
CONT. LOCK STRIP,
SOLDERED
ARCH. TO APPV.
12"-16"1-1/2" HIGHVALLEY DETAIL
PRODUCT LISTING:
ICC # ESR-2048, CB-150
*UNVENTED ENCLOSED RAFTER ASSEMBLY NOTE:
NO INTERIOR CLASS I VAPOR RETARDER SHALL BE INSTALLED ON THE
CEILING SIDE (ATTIC FLOOR) OF THE UNVENTED ATTIC ASSEMBLY OR ON THE
CEILING SIDE OF THE UNVENTED ENCLOSED ROOF FRAMING ASSEMBLY.
1/4" DENSGLASS OR EQUIV.
A-4.11
A-4.1
A-4.0
2
2
2
A-5.4
2
A-5.4
1
A-5.4
1
A-5.4
1
A-5.3
1
A-5.3
1
A-5.1
1
A-5.1
2
A-5.3
2
A-5.3
2
A-5.1
2
A-5.1
2
A-5.0
2
A-5.0
2
A-5.2
2
A-5.2
1
A-5.5
1
A-5.5
1
A-5.0
1
A-5.0
1
A-5.2
1
A-5.210:1210:123:123:129:129:129:129:128:128:128:128:128:128:1212:12
12:12
12:12
12:12 3:12 3:12
3:12 3:12
3:12 3:12
3:12 3:12
10:1210:124:124:124:1210:1210:121.5:12
1.5:12
10:12
10:12
10:12
1
2 1
1
1
1 1
1
2
1
3
3
3
4
4
4
4
4
HT. CERT. REQ'D.
43.08'
HT. CERT. REQ'D.
42.98'
HT. CERT. REQ'D.
43.08'
HT. CERT. REQ'D.
43.08'3:123:123:12HT. CERT. REQ'D.
43.08'
HT. CERT. REQ'D.
43.08'
HT. CERT. REQ'D.
42.98'
37.17'
37.17'
37.17'
38.66'
43.12' T.O.CHIMNEY
44.62' T.O.CHIMNEY
8:128:126:12
6:12
7:1238.07' T.O. POST
37.83' TR
37.96' TW
37.96' TW
R.Y.S.B.7' - 6"L.Y.S.B.7' - 6"F.Y.S.B.
4' - 0"
OCEAN F.Y.S.B.
10' - 0"2' - 5 1/8"1' - 2"1' - 0 1/2"2' MAX.4' MAX.4' MAX.2' MAX.JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT
A-3.0
7/19/19
201837ROOF PLANSTUPIN RESIDENCE
STUPIN RESIDENCEAMDREW & JULIE STUPINC/O. COASTLINE REALESTATE INVESTMENTS215TH STREETHUNTINGTON BEACHCA 92648CDP
3322 VIA LIDO, NEWPORT BEACH, CA 92663JUSTIN JONHSTON
KEYNOTE LEGEND
1 SLATE ROOFING. - REF. MATERIAL SCHEDULE SHT. A-4.0
2 ROOF - STANDING SEAM METAL W/. KYNAR FINISH - COLOR AS SELECTED
3 GUTTER - PER MAT. SCHED. A/A-4.0, SHAPE AS SEL. - PROVIDE SHOP DWGS. TO ARCH.
4 RECESSED GUTTER - PER MAT. SCHED. A/A-4.0, SHAPE AS SEL. - PROVIDE SHOP DWGS. TO ARCH.
1 1/2" = 1'-0"B SLATE TILE ROOFING
1 1/2" = 1'-0"D EAVE DETAIL
1 1/2" = 1'-0"F RAKE DETAIL
NOTE:ALL DIMS. ARE TO FACE OF STUD (F.O.S.) OR FACE OF SHT'G. (F.O.S.) TYP. U.N.O.
EAVE DIMS. ARE FROM FACE OF SHT'G. TO FACE OF FINISH FASCIA
A
1 1/2" = 1'-0"C METAL ROOFING DETAIL
NO. REVISION DATE
PROJECT NORTHTRUE NORTH
1/4" = 1'-0"1 ROOF PLAN
39
WINDOWS & DOORS:
AUTHORIZED DEALER (PRODUCTS LISTED BELOW)
SUPPLIER: ASSOCIATED BUILDING SUPPLY
ADDRESS: STONE MILL DESIGN CENTER 2915 RED HILL AVE., SUITE F104, COSTA MESA, CA
92626
CONTACT: JOE YOUNAN
PHONE: 949-872-3319
FAX: 206-666-2150
EMAIL: JYOUNAN@ABSSOCAL.COM
WEB: WWW.ASSOCIATEDBUILDINGSUPPLY.COM
STEEL WINDOWS AND DOORS
MANUFACTURER: RIVIERA BRONZE -ARCHITECTURAL STEEL WINDOWS AND DOORS
ADDRESS: 1895 NORTH VENTURA AVENUE, VENTURA, CA 93001
CONTACT: DEAN BENTLEY
PHONE: 805.653.1943
FAX: 805.653.1942
EMAIL: DEAN@RIVIERABRONZE.COM
WEB: WWW.RIVIERABRONZE.COM
GUTTERS:
GARAGE DOORS:
SUPPLIER:RANCH HOUSE DOORS
WWW.RANCHHOUSEDOORS.COM
STYLE: CUSTOM
MATERIAL: CUSTOM BUILT, WOOD & GLASS
WATERPROOF DECK MEMBRANE:
FLASHING & WEATHERSTRIPPING:
MATERIAL: METAL -COPPER/ALUM.PAINTED KYNAR
SHAPE: HALF ROUND/SQUARE (5") (VERIFY W/. ARCH.)
WESTCOAT -ALX CUSTOM
770 GATEWAY CENTER DRIVE
SAN DIEGO, CA 92102
800.250.4519
WWW.WESTCOAT.COM
CODE: ICC # ESR-2201
PROVIDE MIN. 24 GUAGE METAL (16 OZ.) SHEETING (TO MATCH) FOR ALL EXTERIOR FLASHING &
WEATHERSTRIPPING APPLICATIONS. VERIFY W/. ARCHITECT ANY UNCONVENTIONAL ENVELOPE
WATERPROOFING AREAS PRIOR TO INSTALLATION.
EXTERIOR STONE/MASONRY VENEER
SUPPLIER:SEPULVEDA BUILDING MATERIAL
28092 FORBES ROAD
LAGUNA NIGUEL,CA 92677
P: 949.347.2100
STONE TYPE:TBD
COLOR: LT. CREAM/GRAY, COLOR GROUT TO MATCH
APPLICATION: 24" x 48" TILE, TIGHT GROUT
THICKNESS: 1" -1.5" NOMINAL
WEIGHT: LESS THAN 15 LBS./S.F.
SLATE ROOFING:
PRODUCT: SLATE, NATURAL STONE
SUPPLIER: TBD
COLOR:DARK GRAY, TO BE APPROVED BY ARCH. & OWNER
APPLICATION: CLOSED VALLEY W./ MITERED HIP CUTS, 16 GAUGE COPPER FLASHING, STAGGERED
COURSING
CODE: CLASS 'A' ASSEMBLY
WEIGHT:APPX. 12 PSF.
METAL ROOFING: ( CLASS 'A' )
MANUFACTURER:
CUSTOM-BILT METALS
13940 MAGNOLIA AVE.
CHINO, CA 91710
P: 909.664.1500
PRODUCT: STANDING SEAM ZINC ROOFING, CB-150
COLOR: MIDNIGHT BRONZE
NOTES:USE CONTINUOUS 16" OR 18" PANS -VERIFY W/. ARCH. SIZE & LOC'N. OF
SEAMS. (NO TRANSVERSE SEAMS) REF. DTL. 1/A-3
WEIGHT:APPX. 2 PSF.
CODE: ICC # ESR-2048, CB-150
HORIZONTAL WOOD SIDING:
MANUFACTURER:
JAMES HARDIE BUILDING PRODUCTS, INC.
10901 ELM AVENUE
FONTANA, CA 92337
P: 909.356.6366
PRODUCT: HARDIEPLANK® LAP SIDING, SMOOTH
COLOR: ARCTIC WHITE, ARCH. TO APPV.
APPLICATION: SHIPLAP 4" PLANK
CODE: ICC# ESR-2290
EXTERIOR METAL PANELING: KYNAR PAINTED ALUM.
MANUFACTURER: OCM, OLD COUNTRY MILLWORK INC.
COLOR: DARK BRONZE
FINISH: ACM PANEL -ARCH. TO APPROVE SIZING/ REVEAL
SECOND FLOOR PLATE (TYP.)
21.30'
SECOND FLOOR PLATE (TYP.)
21.30'
SECOND FLOOR T.O.S. (TYP.)
22.56'
SECOND FLOOR T.O.S. (TYP.)
22.56'
ROOF PLATE (TYP.)
40.32'
ROOF PLATE (TYP.)
40.32'
GRADE PLANE
10.12'
GRADE PLANE
10.12'
MAX. FLAT ROOF
38.12'
MAX. FLAT ROOF
38.12'
MAX. RIDGE
43.12'
MAX. RIDGE
43.12'
THIRD FLOOR PLATE (TYP.)
31.56'
THIRD FLOOR PLATE (TYP.)
31.56'
THIRD FLOOR T.O.S. (TYP.)
32.82'
THIRD FLOOR T.O.S. (TYP.)
32.82'
GARAGE T.O.C.
10.50'
FIRST FLOOR (T.O.S.)
10.00'
1
A-5.1
2
A-5.1
2
A-5.0
1
A-5.0
1
A-5.2
33' - 0"28' - 0"10' - 9 5/8"1' - 3 1/8"9' - 0"1' - 3 1/8"7' - 6"12' - 0 3/4"10' - 3 1/8"11' - 3 5/8"1' - 3 1/8"9' - 0"1' - 3 1/8"7' - 6"12' - 6 3/4"10' - 3 1/8"7
5
1
3
10
5
9
3
7
3
2
6
5
10
12
3
9
4
7
1
8 :1 2
R 5' - 3 1/4"6:12
HT. CERT. REQ'D.
42.98'
HT. CERT. REQ'D.
42.98'
HT. CERT. REQ'D.
43.08'
HT. CERT. REQ'D.
43.08'
38.66'
43.12' T.O.CHIMNEY
27.68'
38.66'
HT. CERT. REQ'D.
44.62'
4
NEW DOCK'S ACCESS BY
OTHER NOT A PART
3
1012 8
91113
4
21 322
232425
4
40 39 38
HD. HT.8' - 0"HD. HT. ABV. T.O.S.8' - 1 1/2"HD. HT. ABV. T.O.S.6' - 1 1/2"HD. HT. ABV. T.O.S.8' - 1 1/2"HD. HT. ABV. T.O.S.10' - 1 1/2"PLPL
AD-1
21
D
A-3.0
D
A-3.0
D
A-3.0
3
A-7.0
2
A-7.0
9
A-7.0
8
A-7.0
5
A-7.0
5
A-7.0
4
A-7.0
10
AD-1
ENTRY FLOOR (T.O.S.)
11.00'
ENTRY FLOOR (T.O.S.)
11.00'
SECOND FLOOR PLATE (TYP.)
21.30'
SECOND FLOOR PLATE (TYP.)
21.30'
SECOND FLOOR T.O.S. (TYP.)
22.56'
SECOND FLOOR T.O.S. (TYP.)
22.56'
ROOF PLATE (TYP.)
40.32'
ROOF PLATE (TYP.)
40.32'
GRADE PLANE
10.12'
GRADE PLANE
10.12'
MAX. FLAT ROOF
38.12'
MAX. FLAT ROOF
38.12'
MAX. RIDGE
43.12'
MAX. RIDGE
43.12'
THIRD FLOOR PLATE (TYP.)
31.56'
THIRD FLOOR PLATE (TYP.)
31.56'
THIRD FLOOR T.O.S. (TYP.)
32.82'
THIRD FLOOR T.O.S. (TYP.)
32.82'
GARAGE T.O.C.
10.50'
GARAGE T.O.C.
10.50'
2
A-5.4
1
A-5.4
1
A-5.3
2
A-5.3
2
A-5.2
1
A-5.5
6"10' - 3 5/8"1' - 3 1/8"9' - 0"1' - 3 1/8"7' - 6"11' - 6 3/4"10' - 3 1/8"33' - 0"28' - 0"6"10' - 3 5/8"1' - 3 1/8"9' - 0"1' - 3 1/8"7' - 6"11' - 6 3/4"10' - 3 1/8"1
2
33
2
3
4
5
66
1
7
1
4 8
7
5
4
5
3 :1 2
10 :12
1
0:12
8 :1 2 8:12 8 :1 2 8:12 8 :1 2 8:12
1 0 :1 2 1
0:1
2
3:12
9
4
9
10
8
11
7:12
12
9
8
8 :1 2 8:12
T Y P .R 5' - 3 1 /4 "9 :1 2
HT. CERT. REQ'D.
43.08'
HT. CERT. REQ'D.
43.08'
HT. CERT. REQ'D.
43.08'
37.17'37.17'37.17'
27.68'
43.12' T.O.CHIMNEY
44.62' T.O.CHIMNEY
11
20
12
7
15
4 23
6
11
36
333435
2
37
R
5' - 3 1/4"HD. HT. ABV. T.O.S.14' - 0"HD. HT. ABV. T.O.S.11' - 7 1/2"HD. HT. ABV. T.O.S.8' - 6"HD. HT. ABV. T.O.S.16' - 3 1/8"HD. HT. ABV. T.O.S.8' - 6"HD. HT. ABV. T.O.S.16' - 3 1/8"HD. HT. ABV. T.O.S.9' - 7 1/2"PL PL
F
A-3.0
F
A-3.0
D
A-3.0
AD-1
21
5
A-7.0
4
A-7.0
3
A-7.0
2
A-7.0
F
A-3.0
JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT
A-4.0
7/19/19
201837EXTERIOR ELEVATIONS &MATERIAL SCHEDULESTUPIN RESIDENCE
STUPIN RESIDENCEAMDREW & JULIE STUPINC/O. COASTLINE REALESTATE INVESTMENTS215TH STREETHUNTINGTON BEACHCA 92648CDP
3322 VIA LIDO, NEWPORT BEACH, CA 92663JUSTIN JONHSTON
KEYNOTE LEGEND
1 MASONRY STONE VENEER AS SELECTED - REF. MAT. SCHED. A/A-4.0
2 KYNAR PAINTED ALUM. ACM PANELING (OLD COUNTRY MILLWORKS- TINTED OBSIDIAN/ BLACK)-ARCH TO APPV.
SIZE & REVEAL. INSTALL PER MANUF. SPECIFICATIONS REF. 9/AD-1
3 ROOF - STANDING SEAM METAL W/. KYNAR FINISH - COLOR AS SELECTED
4 WOOD SIDING - REF. MATERIAL SCHEDULE A/A-4.0
5 MDX WOOD PANELING, PAINTED WHITE - ARCH. TO APPV.
6 DECO. WD. CORBEL - VERIFY SIZE & LOC'N. W/. ARCH.
7 SLATE ROOFING. - REF. MATERIAL SCHEDULE SHT. A-4.0
8 CROWN MOULDING, SEAL AND PAINT AS SEL. - ARCH. TO APPV. PROFILE
9 DOWNSPOUT - COPPER/ALUMINUM W/. KYNAR FINISH OR EQUIV. - AS SEL. (ARCH. TO APPROVE)
10 GUTTER - PER MAT. SCHED. A/A-4.0, SHAPE AS SEL. - PROVIDE SHOP DWGS. TO ARCH.
11 COLLECTOR TO MATCH DOWNSPOUT AND GUTTER MAT., REF. AMT. SCHED. A/A-4.0 - ARCH. TOP APPV.
12 FURNISHINGS - AS SELECTED
MATERIAL SCHEDULEA
1/4" = 1'-0"2 LEFT ELEVATION - NORTH
1/4" = 1'-0"1 FRONT ELEVATION -WEST
NOTE: REF. ROOF PLAN (A-3.0) FOR ALL PLATE HTS. & RIDGE HTS.
NOTE: FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT
LABELS.
NO. REVISION DATE
40
SECOND FLOOR PLATE (TYP.)
21.30'
SECOND FLOOR PLATE (TYP.)
21.30'
SECOND FLOOR T.O.S. (TYP.)
22.56'
SECOND FLOOR T.O.S. (TYP.)
22.56'
ROOF PLATE (TYP.)
40.32'
ROOF PLATE (TYP.)
40.32'
GRADE PLANE
10.12'
GRADE PLANE
10.12'
MAX. FLAT ROOF
38.12'
MAX. FLAT ROOF
38.12'
MAX. RIDGE
43.12'
MAX. RIDGE
43.12'
THIRD FLOOR PLATE (TYP.)
31.56'
THIRD FLOOR PLATE (TYP.)
31.56'
THIRD FLOOR T.O.S. (TYP.)
32.82'
THIRD FLOOR T.O.S. (TYP.)
32.82'
ROOF DECK PLATE
33.25'
ROOF DECK PLATE
33.25'
ROOF DECK T.O.S.
34.33'
ROOF DECK T.O.S.
34.33'
2
A-5.4
FIRST FLOOR (T.O.S.)
10.00'
FIRST FLOOR (T.O.S.)
10.00'
1
A-5.4
1
A-5.3
2
A-5.3
2
A-5.2
1
A-5.5
33' - 0"28' - 0"11' - 3 5/8"1' - 3 1/8"9' - 0"1' - 3 1/8"7' - 6"12' - 5 1/4"10' - 8 1/4"1' - 1"10' - 3 1/8"1' - 6 1/8"11' - 3 5/8"1' - 3 1/8"9' - 0"1' - 3 1/8"7' - 6"12' - 6 3/4"10' - 8 1/4"1' - 1"10' - 3 1/8"1' - 6 1/8"1
2
3
4 3 :1 2
10 :12
1
0:1
2
7 :1 2
8 :1 2 8:12
9 :1 2 9:12
9 :1 2 9:12
3:123:1 2
5
2
6
7
1
5
1
58
8
6
7
4 :1 2 4:12
5
5
5
9 9
10
3:12
HT. CERT. REQ'D.
43.08'
HT. CERT. REQ'D.
43.08'
HT. CERT. REQ'D.
42.98'
HT. CERT. REQ'D.
43.08'
38.66'
34.73'
43.12' T.O.CHIMNEY
44.62' T.O.CHIMNEY
37.96' TW 37.83' TR
NEW DOCK'S ACCESS BY
OTHER NOT A PART
PROPOSED ACCESS POINT FOR THE NEW
DOCK'S ACCESS -PROVIDE 42" HIGH GUARD
ABV. FS/FG UNTIL AFTER THE NEW DOCK'S
ACCESS CONSTRUCTED
ABV.F.F.42" MIN.ABV.F.F.42" MIN.9
9
26
5
567
9 8
14151617
171819
8
46
131415
ABV. F.F.42" MIN.ABV. F.F.42" MIN.ABV. F.F.42" MIN.HD. HT. ABV. T.O.S.8' - 0"HD. HT. ABV. T.O.S.7' - 6"PLPL
AD-1
21
AD-1
21
3
A-7.0
4
A-7.0
F
A-3.0
5
A-7.0 7
A-7.0
D
A-3.0
D
A-3.0
4
A-7.0
15
AD-1
14
AD-1
13
AD-1
SECOND FLOOR PLATE (TYP.)
21.30'
SECOND FLOOR PLATE (TYP.)
21.30'
SECOND FLOOR T.O.S. (TYP.)
22.56'
SECOND FLOOR T.O.S. (TYP.)
22.56'
ROOF PLATE (TYP.)
40.32'
ROOF PLATE (TYP.)
40.32'
GRADE PLANE
10.12'
GRADE PLANE
10.12'
MAX. FLAT ROOF
38.12'
MAX. FLAT ROOF
38.12'
MAX. RIDGE
43.12'
MAX. RIDGE
43.12'
THIRD FLOOR PLATE (TYP.)
31.56'
THIRD FLOOR PLATE (TYP.)
31.56'
THIRD FLOOR T.O.S. (TYP.)
32.82'
THIRD FLOOR T.O.S. (TYP.)
32.82'
ROOF DECK PLATE
33.25'
ROOF DECK PLATE
33.25'
ROOF DECK T.O.S.
34.33'
ROOF DECK T.O.S.
34.33'
GARAGE T.O.C.
10.50'
FIRST FLOOR (T.O.S.)
10.00'
1
A-5.1
2
A-5.1
2
A-5.0
1
A-5.0
1
A-5.2
33' - 0"28' - 0"7' - 6"1' - 3 1/8"9' - 0"1' - 3 1/8"11' - 3 5/8"1' - 1"10' - 8 1/4"12' - 6 3/4"1' - 6 1/8"10' - 3 1/8"7' - 6"1' - 3 1/8"9' - 0"1' - 3 1/8"10' - 9 5/8"1' - 1"10' - 8 1/4"12' - 0 3/4"1' - 6 1/8"10' - 3 1/8"11
2
7
8
R
5' -
3
1/
4
"
7
8
7
1
7
6
6 :1 2
5
9
6
12
13
14
1
2
7
5
8:12
4:12
15 15
44.62' T.O.CHIMNEY
HT. CERT. REQ'D.
43.08'
HT. CERT. REQ'D.
43.08'43.12' T.O.CHIMNEY
38.66'
27.68'
692728
1819
2930
313210
10
49 48 47
ABV. F.F.42" MIN.16
HD. HT. ABV. T.O.S.9' - 1 1/2"HD. HT. ABV. T.O.S.8' - 1 1/2"HD. HT. ABV. T.O.S.6' - 7 1/2"PL PL
AD-1
21
D
A-3.0
F
A-3.0
2
A-7.0
3
A-7.0
4
A-7.0
5
A-7.0
9
A-7.0
8
A-7.0
10
A-7.0
11
WINDOWS & DOORS:
AUTHORIZED DEALER (PRODUCTS LISTED BELOW)
SUPPLIER: ASSOCIATED BUILDING SUPPLY
ADDRESS: STONE MILL DESIGN CENTER 2915 RED HILL AVE., SUITE F104, COSTA MESA, CA
92626
CONTACT: JOE YOUNAN
PHONE: 949-872-3319
FAX: 206-666-2150
EMAIL: JYOUNAN@ABSSOCAL.COM
WEB: WWW.ASSOCIATEDBUILDINGSUPPLY.COM
STEEL WINDOWS AND DOORS
MANUFACTURER: RIVIERA BRONZE -ARCHITECTURAL STEEL WINDOWS AND DOORS
ADDRESS: 1895 NORTH VENTURA AVENUE, VENTURA, CA 93001
CONTACT: DEAN BENTLEY
PHONE: 805.653.1943
FAX: 805.653.1942
EMAIL: DEAN@RIVIERABRONZE.COM
WEB: WWW.RIVIERABRONZE.COM
GUTTERS:
GARAGE DOORS:
SUPPLIER:RANCH HOUSE DOORS
WWW.RANCHHOUSEDOORS.COM
STYLE: CUSTOM
MATERIAL: CUSTOM BUILT, WOOD & GLASS
WATERPROOF DECK MEMBRANE:
FLASHING & WEATHERSTRIPPING:
MATERIAL: METAL -COPPER/ALUM.PAINTED KYNAR
SHAPE: HALF ROUND/SQUARE (5") (VERIFY W/. ARCH.)
WESTCOAT -ALX CUSTOM
770 GATEWAY CENTER DRIVE
SAN DIEGO, CA 92102
800.250.4519
WWW.WESTCOAT.COM
CODE: ICC # ESR-2201
PROVIDE MIN. 24 GUAGE METAL (16 OZ.) SHEETING (TO MATCH) FOR ALL EXTERIOR FLASHING &
WEATHERSTRIPPING APPLICATIONS. VERIFY W/. ARCHITECT ANY UNCONVENTIONAL ENVELOPE
WATERPROOFING AREAS PRIOR TO INSTALLATION.
EXTERIOR STONE/MASONRY VENEER
SUPPLIER:SEPULVEDA BUILDING MATERIAL
28092 FORBES ROAD
LAGUNA NIGUEL,CA 92677
P: 949.347.2100
STONE TYPE:TBD
COLOR: LT. CREAM/GRAY, COLOR GROUT TO MATCH
APPLICATION: 24" x 48" TILE, TIGHT GROUT
THICKNESS: 1" -1.5" NOMINAL
WEIGHT: LESS THAN 15 LBS./S.F.
SLATE ROOFING:
PRODUCT: SLATE, NATURAL STONE
SUPPLIER: TBD
COLOR:DARK GRAY, TO BE APPROVED BY ARCH. & OWNER
APPLICATION: CLOSED VALLEY W./ MITERED HIP CUTS, 16 GAUGE COPPER FLASHING, STAGGERED
COURSING
CODE: CLASS 'A' ASSEMBLY
WEIGHT:APPX. 12 PSF.
METAL ROOFING: ( CLASS 'A' )
MANUFACTURER:
CUSTOM-BILT METALS
13940 MAGNOLIA AVE.
CHINO, CA 91710
P: 909.664.1500
PRODUCT: STANDING SEAM ZINC ROOFING, CB-150
COLOR: MIDNIGHT BRONZE
NOTES:USE CONTINUOUS 16" OR 18" PANS -VERIFY W/. ARCH. SIZE & LOC'N. OF
SEAMS. (NO TRANSVERSE SEAMS) REF. DTL. 1/A-3
WEIGHT:APPX. 2 PSF.
CODE: ICC # ESR-2048, CB-150
HORIZONTAL WOOD SIDING:
MANUFACTURER:
JAMES HARDIE BUILDING PRODUCTS, INC.
10901 ELM AVENUE
FONTANA, CA 92337
P: 909.356.6366
PRODUCT: HARDIEPLANK® LAP SIDING, SMOOTH
COLOR: ARCTIC WHITE, ARCH. TO APPV.
APPLICATION: SHIPLAP 4" PLANK
CODE: ICC# ESR-2290
EXTERIOR METAL PANELING: KYNAR PAINTED ALUM.
MANUFACTURER: OCM, OLD COUNTRY MILLWORK INC.
COLOR: DARK BRONZE
FINISH: ACM PANEL -ARCH. TO APPROVE SIZING/ REVEAL
JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT
A-4.1
7/19/19
201837EXTERIOR ELEVATIONSTUPIN RESIDENCE
STUPIN RESIDENCEAMDREW & JULIE STUPINC/O. COASTLINE REALESTATE INVESTMENTS215TH STREETHUNTINGTON BEACHCA 92648CDP
3322 VIA LIDO, NEWPORT BEACH, CA 92663JUSTIN JONHSTON
NO. REVISION DATE
1/4" = 1'-0"1 OCEAN FRONT ELEVATION - EAST
1/4" = 1'-0"2 RIGHT ELEVATION - SOUTH
KEYNOTE LEGEND
1 WOOD SIDING - REF. MATERIAL SCHEDULE A/A-4.0
2 DOWNSPOUT - COPPER/ALUMINUM W/. KYNAR FINISH OR EQUIV. - AS SEL. (ARCH. TO APPROVE)
3 GUTTER - PER MAT. SCHED. A/A-4.0, SHAPE AS SEL. - PROVIDE SHOP DWGS. TO ARCH.
4 CROWN MOULDING, SEAL AND PAINT AS SEL. - ARCH. TO APPV. PROFILE
5 MASONRY STONE VENEER AS SELECTED - REF. MAT. SCHED. A/A-4.0
6 MDX WOOD PANELING, PAINTED WHITE - ARCH. TO APPV.
7 ROOF - STANDING SEAM METAL W/. KYNAR FINISH - COLOR AS SELECTED
8 SLATE ROOFING. - REF. MATERIAL SCHEDULE SHT. A-4.0
9 EXTERIOR GLASS GUARDRAIL - MIN. 42" HEIGHT - 4" MAX. SPHERE OPENING, REF. DTL. 9 & 13/AD-1
10 EXTERIOR GUARDRAIL - MIN. 42" HEIGHT - 4" MAX. SPHERE OPENING, REF. DTL. 9 & 13/AD-1
11 COLLECTOR TO MATCH DOWNSPOUT AND GUTTER MAT., REF. AMT. SCHED. A/A-4.0 - ARCH. TOP APPV.
12 FURNISHINGS - AS SELECTED
13 DECO. WD. CORBEL - VERIFY SIZE & LOC'N. W/. ARCH.
14 KYNAR PAINTED ALUM. ACM PANELING (OLD COUNTRY MILLWORKS- TINTED OBSIDIAN/ BLACK)-ARCH TO
APPV. SIZE & REVEAL. INSTALL PER MANUF. SPECIFICATIONS REF. 9/AD-1
15 A/C. CONDENSER UNIT - SIZE TBD - PROVIDE POWER AND SOUND DAMPENING PAD AS REQ'D. (SOUND
ATT. REQ'D. PER SECTION 10.26.045 NBMC UNDER SEPARATE PERMIT)
16 MAIN SERVICE PANEL, 400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION)
MATERIAL SCHEDULEA
NOTE: REF. ROOF PLAN (A-3.0) FOR ALL PLATE HTS. & RIDGE HTS.
NOTE: FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT
LABELS.
41
FIREBLOCKING AND DRAFTSTOPPING SHALL BE INSTALLED TO CUT OFF ALL CONCEALED DRAFT OPENINGS
(BOTH VERTICAL AND HORIZONTAL) AND SHALL FORM AN EFFECTIVE BARRIER BETWEEN FLOORS, BETWEEN A
TOP STORY AND A ROOF OR ATTIC SPACE, AND SHALL SUBDIVIDE ATTIC SPACES, CONCEALED ROOF SPACES
AND FLOOR-CEILING ASSEMBLIES. THE INTEGRITY OF ALL FIRE BLOCKS AND DRAFT STOPS SHALL BE
MAINTAINED.
FIRE BLOCKS.
FIREBLOCKING SHALL BE PROVIDED IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING
FURRED SPACES, AT THE CEILING AND FLOOR LEVELS AND AT 10-FOOT INTERVALS BOTH VERTICAL AND
HORIZONTAL.
FIRE BLOCK CONSTRUCTION. FIREBLOCKING SHALL CONSIST OF 2 INCHES NOMINAL LUMBER. FIRE BLOCKS MAY
ALSO BE OF GYPSUM BOARD, CEMENT FIBER BOARD, BATTS OR BLANKETS OF MINERAL OR GLASS FIBER, OR
OTHER APPROVED MATERIALS INSTALLED IN SUCH A MANNER AS TO BE SECURELY RETAINED IN PLACE. LOOSE-
FILL INSULATION MATERIAL SHALL NOT BE USED.
WALLS HAVING PARALLEL OR STAGGERED STUDS FOR SOUND-TRANSMISSION CONTROL SHALL HAVE FIRE
BLOCKS OF BATTS OR BLANKETS OF MINERAL OR GLASS FIBER OR OTHER APPROVED FLEXIBLE MATERIALS.
DRAFT STOPS.
DRAFTSTOPPING SHALL BE PROVIDED IN THE LOCATIONS SET FORTH IN THIS SECTION.
FLOOR-CEILING ASSEMBLIES.
DRAFT STOPS SHALL BE INSTALLED IN FLOOR-CEILING ASSEMBLIES OF THE BUILDING. SUCH DRAFT STOPS
SHALL BE IN LINE WITH WALLS SEPARATING INDIVIDUAL DWELLING UNITS FROM EACH OTHER AND FROM OTHER
AREAS.
ATTICS.
DRAFT STOPS SHALL BE INSTALLED IN THE ATTICS, MANSARDS, OVERHANGS, FALSE FRONTS SET OUT FROM
WALLS AND SIMILAR CONCEALED SPACES OF THIS BUILDING. SUCH DRAFT STOPS SHALL BE ABOVE AND IN LINE
WITH THE WALLS SEPARATING INDIVIDUAL DWELLING UNITS FROM EACH OTHER AND FROM OTHER USES.
DRAFT STOP CONSTRUCTION.
DRAFTSTOPPING MATERIALS SHALL NOT BE LESS THAN ½-INCH GYPSUM BOARD, 3/8-INCH WOOD STRUCTURAL
PANEL, 3/8-INCH TYPE 2-M PARTICLEBOARD OR OTHER APPROVED MATERIALS ADEQUATELY SUPPORTED.
OPENINGS IN THE PARTITIONS SHALL BE PROTECTED BY SELF-CLOSING DOORS WITH AUTOMATIC LATCHES
CONSTRUCTED AS REQUIRED FOR THE PARTITIONS.
FIRE-BLOCKING & DRAFT-STOP NOTE
INSULATION SCHEDULE:
EXTERIOR WALL:
2 x 4 CONST. = R-13 MIN.
2 x 6 CONST. OR LARGER =R-19
RAISED FLOOR:R-30 MIN.
ROOF:R-30
(REF. T-24 REPORT FOR MORE INFORMATION)
NOTE: PROVIDE BID FOR INSULATION OF ENTIRE HOME
NEW WALL -2 x 6 STUDS @ 16" O.C. U.N.O.
NEW WALL -2 x 4 STUDS @ 16" O.C. U.N.O.
WALL W/. STONE VENEER -2x STUDS @ 16" O.C. U.N.O.
CONCRETE RETAINING WALL -REF. STRUCTURAL
SEPARATION LEGEND
EXTERIOR FIRE RATED PARTITION REF. DTL. 5/AD-1
1 HR. FIRE RATED PARTITION REF. DTL. 7/AD-1
1 HR. FLOOR SYSTEM REF. DTL. 7/AD-1
INSULATED SYS. REF. INSULATION SCHEDULE THIS SHT.
B
ENTRY FLOOR (T.O.S.)
11.00'
ENTRY FLOOR (T.O.S.)
11.00'
SECOND FLOOR PLATE (TYP.)
21.30'
SECOND FLOOR PLATE (TYP.)
21.30'
SECOND FLOOR T.O.S. (TYP.)
22.56'
SECOND FLOOR T.O.S. (TYP.)
22.56'
ROOF PLATE (TYP.)
40.32'
ROOF PLATE (TYP.)
40.32'
GRADE PLANE
10.12'
GRADE PLANE
10.12'
MAX. FLAT ROOF
38.12'
MAX. FLAT ROOF
38.12'
MAX. RIDGE
43.12'
MAX. RIDGE
43.12'
THIRD FLOOR PLATE (TYP.)
31.56'
THIRD FLOOR PLATE (TYP.)
31.56'
THIRD FLOOR T.O.S. (TYP.)
32.82'
THIRD FLOOR T.O.S. (TYP.)
32.82'
GARAGE T.O.C.
10.50'
GARAGE T.O.C.
10.50'
2
A-5.4
1
A-5.4
1
A-5.3
2
A-5.3
2
A-5.2
1
A-5.5
BEDROOM #2
2-CAR GARAGE 2
LAUNDRY
MUD ROOMFOYER
STAIRS
STAIRS
BEDROOM #3
2-CAR GARAGE 1
6"10' - 3 5/8"1' - 3 1/8"9' - 0"1' - 3 1/8"7' - 6"12' - 0 3/4"10' - 3 1/8"6"10' - 3 5/8"1' - 3 1/8"9' - 0"1' - 3 1/8"7' - 6"12' - 0 3/4"10' - 3 1/8"1
2
3
4
5
6
7 8
11
1 0:1 21
0:1
2
3 :1 2
9 :1 2
1 0:1 21
0:12
3:12
7:12
24232221
13
29333435
8"8"ABV. F.F.42" MIN.7 3/4"36" TYP.34" - 38"PL PL18' - 9 1/8"15' - 7 1/4"10' - 2 1/8"11' - 4 3/8"18' - 9 1/8"8
AD-1
8
AD-1
7
AD-1
7
AD-1
7
AD-1
7
AD-1
AD-1
9
A-3.0
D
10
9
ENTRY FLOOR (T.O.S.)
11.00'
ENTRY FLOOR (T.O.S.)
11.00'
SECOND FLOOR PLATE (TYP.)
21.30'
SECOND FLOOR PLATE (TYP.)
21.30'
SECOND FLOOR T.O.S. (TYP.)
22.56'
SECOND FLOOR T.O.S. (TYP.)
22.56'
ROOF PLATE (TYP.)
40.32'
ROOF PLATE (TYP.)
40.32'
GRADE PLANE
10.12'
GRADE PLANE
10.12'
MAX. FLAT ROOF
38.12'
MAX. FLAT ROOF
38.12'
MAX. RIDGE
43.12'
MAX. RIDGE
43.12'
THIRD FLOOR PLATE (TYP.)
31.56'
THIRD FLOOR PLATE (TYP.)
31.56'
THIRD FLOOR T.O.S. (TYP.)
32.82'
THIRD FLOOR T.O.S. (TYP.)
32.82'
2
A-5.4
FIRST FLOOR (T.O.S.)
10.00'
FIRST FLOOR (T.O.S.)
10.00'
1
A-5.4
1
A-5.3
2
A-5.3
2
A-5.2
1
A-5.5
BEDROOM #5
FAMILY ROOM
W.I.C.W.I.C.BATH #3
GAME ROOM
GREAT ROOMDINING ROOMKITCHEN
BUTLER'S
KITCHEN11' - 3 5/8"1' - 3 1/8"9' - 0"1' - 3 1/8"7' - 6"1' - 0"11' - 6 3/4"10' - 3 1/8"11' - 3 5/8"1' - 3 1/8"9' - 0"1' - 3 1/8"7' - 6"1' - 0"11' - 6 3/4"10' - 3 1/8"9
1
10
3
4
11
12
3 :1 2 3:12 3 :1 2
3:12
9:1210:12
7 :1 2
353433
3534
4241
20212223
1 51 ABV. F.F.42" MIN.TYP.7 3/4"ABV. F.F.34" - 38"PLPL
10' - 5 1/8"10' - 6 5/8"9' - 0"9' - 4"9' - 2 7/8"A-3.0
D
AD-1
6
6 7135
10 14
15
7
6
16
17
5
6 713
5
18
19
6667
5
20 20675
Name
Elevation
A101
1
SIM
Room name
150 SF
101
1i
?
90 00' 00"
Distance
N E
1
1
A101
SIM
R @ 7 1/2"20
1i
NORTH ARROW
PROPERTY LINE TAG
SECTION INDICATOR
ROOM TAG (NAME / AREA)
CALL-OUT TAG
ELEVATION INDICATOR
KEYNOTE TAG
WINDOW TAG
DOOR TAG
WALL TAG
REVISION FLAG
STAIR TAG (NO. OF RISER & HEIGHT)
JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT
A-5.0
7/19/19
201837BUILDING SECTIONSSTUPIN RESIDENCE
STUPIN RESIDENCEAMDREW & JULIE STUPINC/O. COASTLINE REALESTATE INVESTMENTS215TH STREETHUNTINGTON BEACHCA 92648CDP
3322 VIA LIDO, NEWPORT BEACH, CA 92663JUSTIN JONHSTON
KEYNOTE LEGEND
1 STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS
THAN 1 FOOT CANDLE (CBC 1205.4) REF. DTL. 3/AD-1
2 RESIDENTIAL HYDRAULIC ELEVATOR - 'WAUPACA ELEVATOR COMPANY' OR EQUIV., SHAFT SIZE APPX. = 60"
X 68" CLEAR - PROVIDE SHOP DWGS. TO ARCH. PRIOR TO PURCHASE & INSTALLATION
3 FLOOR JOISTS - REF. STRUCT.
4 ROOF RAFTERS - REF. STRUCT.
5 UPPER CABINET - BUILT-IN, FINISH AS SEL.
6 COUNTERTOP - AS SELECTED
7 BASE CABINET - BUILT-IN, FINISH AS SEL.
8 DRYER - PROVIDE 4" MIN. DIA. DUCT, 14' MAX. LENGTH INCLUDING (2) 90 DEGREE ELBOWS, DEDUCT TWO(2)
FEET FOR EACH 90 DEGREE ELBOW IN EXCESS OF TWO(2) (CMC 504.3.2)
9 INTERIOR GUARDRAIL - MIN. 42" HIGH - MATERIAL AS SELECTED, <4" MAX. SPHERE OPENING, REF. DTL.
4/AD-1
10 HANDRAIL - 34" - 38" ABOVE STAIR NOSING (36" U.N.O.) - MATERIAL AS SELECTED, REF. DTLS. 2, 4/AD-1
11 CONCRETE FOOTING - REF. STRUCT.
12 FURNISHINGS - AS SELECTED
13 BAR SINK - AS SELECTED
14 SHELF AND POLE - BUILT IN, FINISH AS SEL.
15 WALL MOUNTED LIGHT FIXTURE, SCONCE
16 SINK - AS SELECTED (VERIFY COUNTER OR WALL MOUNT FIXTURES W/. OWNER)
17 WINE RACKS - AS SELECTED - PROVIDE SHOP DWGS. TO ARCH & OWNER
18 TALL CABINET - BUILT-IN, FINISH AS SEL.
19 A/C. CONDENSER UNIT - SIZE TBD - PROVIDE POWER AND SOUND DAMPENING PAD AS REQ'D. (SOUND ATT.
REQ'D. PER SECTION 10.26.045 NBMC UNDER SEPARATE PERMIT)
20 REFRIGERATOR - VERIFY APPLIANCE W/. OWNER
NO. REVISION DATE
1/4" = 1'-0"1 LONGITUDINAL SECTION
1/4" = 1'-0"2 LONGITUDINAL SECTION
ANNOTATION LEGENDA
42
FIREBLOCKING AND DRAFTSTOPPING SHALL BE INSTALLED TO CUT OFF ALL CONCEALED DRAFT OPENINGS
(BOTH VERTICAL AND HORIZONTAL) AND SHALL FORM AN EFFECTIVE BARRIER BETWEEN FLOORS, BETWEEN A
TOP STORY AND A ROOF OR ATTIC SPACE, AND SHALL SUBDIVIDE ATTIC SPACES, CONCEALED ROOF SPACES
AND FLOOR-CEILING ASSEMBLIES. THE INTEGRITY OF ALL FIRE BLOCKS AND DRAFT STOPS SHALL BE
MAINTAINED.
FIRE BLOCKS.
FIREBLOCKING SHALL BE PROVIDED IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING
FURRED SPACES, AT THE CEILING AND FLOOR LEVELS AND AT 10-FOOT INTERVALS BOTH VERTICAL AND
HORIZONTAL.
FIRE BLOCK CONSTRUCTION. FIREBLOCKING SHALL CONSIST OF 2 INCHES NOMINAL LUMBER. FIRE BLOCKS MAY
ALSO BE OF GYPSUM BOARD, CEMENT FIBER BOARD, BATTS OR BLANKETS OF MINERAL OR GLASS FIBER, OR
OTHER APPROVED MATERIALS INSTALLED IN SUCH A MANNER AS TO BE SECURELY RETAINED IN PLACE. LOOSE-
FILL INSULATION MATERIAL SHALL NOT BE USED.
WALLS HAVING PARALLEL OR STAGGERED STUDS FOR SOUND-TRANSMISSION CONTROL SHALL HAVE FIRE
BLOCKS OF BATTS OR BLANKETS OF MINERAL OR GLASS FIBER OR OTHER APPROVED FLEXIBLE MATERIALS.
DRAFT STOPS.
DRAFTSTOPPING SHALL BE PROVIDED IN THE LOCATIONS SET FORTH IN THIS SECTION.
FLOOR-CEILING ASSEMBLIES.
DRAFT STOPS SHALL BE INSTALLED IN FLOOR-CEILING ASSEMBLIES OF THE BUILDING. SUCH DRAFT STOPS
SHALL BE IN LINE WITH WALLS SEPARATING INDIVIDUAL DWELLING UNITS FROM EACH OTHER AND FROM OTHER
AREAS.
ATTICS.
DRAFT STOPS SHALL BE INSTALLED IN THE ATTICS, MANSARDS, OVERHANGS, FALSE FRONTS SET OUT FROM
WALLS AND SIMILAR CONCEALED SPACES OF THIS BUILDING. SUCH DRAFT STOPS SHALL BE ABOVE AND IN LINE
WITH THE WALLS SEPARATING INDIVIDUAL DWELLING UNITS FROM EACH OTHER AND FROM OTHER USES.
DRAFT STOP CONSTRUCTION.
DRAFTSTOPPING MATERIALS SHALL NOT BE LESS THAN ½-INCH GYPSUM BOARD, 3/8-INCH WOOD STRUCTURAL
PANEL, 3/8-INCH TYPE 2-M PARTICLEBOARD OR OTHER APPROVED MATERIALS ADEQUATELY SUPPORTED.
OPENINGS IN THE PARTITIONS SHALL BE PROTECTED BY SELF-CLOSING DOORS WITH AUTOMATIC LATCHES
CONSTRUCTED AS REQUIRED FOR THE PARTITIONS.
FIRE-BLOCKING & DRAFT-STOP NOTE
INSULATION SCHEDULE:
EXTERIOR WALL:
2 x 4 CONST. = R-13 MIN.
2 x 6 CONST. OR LARGER =R-19
RAISED FLOOR:R-30 MIN.
ROOF:R-30
(REF. T-24 REPORT FOR MORE INFORMATION)
NOTE: PROVIDE BID FOR INSULATION OF ENTIRE HOME
NEW WALL -2 x 6 STUDS @ 16" O.C. U.N.O.
NEW WALL -2 x 4 STUDS @ 16" O.C. U.N.O.
WALL W/. STONE VENEER -2x STUDS @ 16" O.C. U.N.O.
CONCRETE RETAINING WALL -REF. STRUCTURAL
SEPARATION LEGEND
EXTERIOR FIRE RATED PARTITION REF. DTL. 5/AD-1
1 HR. FIRE RATED PARTITION REF. DTL. 7/AD-1
1 HR. FLOOR SYSTEM REF. DTL. 7/AD-1
INSULATED SYS. REF. INSULATION SCHEDULE THIS SHT.
B
SECOND FLOOR PLATE (TYP.)
21.30'
SECOND FLOOR PLATE (TYP.)
21.30'
SECOND FLOOR T.O.S. (TYP.)
22.56'
SECOND FLOOR T.O.S. (TYP.)
22.56'
ROOF PLATE (TYP.)
40.32'
ROOF PLATE (TYP.)
40.32'
GRADE PLANE
10.12'
GRADE PLANE
10.12'
MAX. FLAT ROOF
38.12'
MAX. FLAT ROOF
38.12'
MAX. RIDGE
43.12'
MAX. RIDGE
43.12'
THIRD FLOOR PLATE (TYP.)
31.56'
THIRD FLOOR PLATE (TYP.)
31.56'
THIRD FLOOR T.O.S. (TYP.)
32.82'
THIRD FLOOR T.O.S. (TYP.)
32.82'
ROOF DECK PLATE
33.25'
ROOF DECK PLATE
33.25'
ROOF DECK T.O.S.
34.33'
ROOF DECK T.O.S.
34.33'
2
A-5.4
FIRST FLOOR (T.O.S.)
10.00'
FIRST FLOOR (T.O.S.)
10.00'
1
A-5.4
1
A-5.3
2
A-5.3
2
A-5.2
1
A-5.5
FAMILY ROOM
BATH #4W.I.C.MASTER SUITEMASTER W.I.C.
BEDROOM #5
GAME ROOM
GREAT ROOM DINING ROOM KITCHEN BUTLER'S
KITCHEN
11' - 3 5/8"1' - 3 1/8"9' - 0"1' - 3 1/8"7' - 6"12' - 6 3/4"10' - 8 1/4"1' - 1"5' - 11 7/8"11' - 3 5/8"1' - 3 1/8"9' - 0"1' - 3 1/8"7' - 6"12' - 6 3/4"10' - 8 1/4"1' - 1"5' - 11 7/8"1
2
3
4
5
6
7
8
3 :1 2
3:12
9 :1 2
3 :1 2
3:12
10:12
41
44
17 18
28
98
1514 16 17
76
5 ABV. F.F.42" MIN.PL PL9' - 4"9' - 2 7/8"8' - 10 1/2"9' - 0"SOFFIT10' - 0 5/8"SOFFIT10' - 6 5/8"SOFFIT10' - 5 1/8"SOFFIT9' - 5 1/8"A-3.0
D
AD-1
6
7
10
7
7
10
20
1118
8
11
15
13
111818
13
1118
ENTRY FLOOR (T.O.S.)
11.00'
ENTRY FLOOR (T.O.S.)
11.00'
SECOND FLOOR PLATE (TYP.)
21.30'
SECOND FLOOR PLATE (TYP.)
21.30'
SECOND FLOOR T.O.S. (TYP.)
22.56'
SECOND FLOOR T.O.S. (TYP.)
22.56'
ROOF PLATE (TYP.)
40.32'
ROOF PLATE (TYP.)
40.32'
GRADE PLANE
10.12'
GRADE PLANE
10.12'
MAX. FLAT ROOF
38.12'
MAX. FLAT ROOF
38.12'
MAX. RIDGE
43.12'
MAX. RIDGE
43.12'
THIRD FLOOR PLATE (TYP.)
31.56'
THIRD FLOOR T.O.S. (TYP.)
32.82'
ROOF DECK PLATE
33.25'ROOF DECK PLATE
33.25'
ROOF DECK T.O.S.
34.33'
ROOF DECK T.O.S.
34.33'
2
A-5.4
FIRST FLOOR (T.O.S.)
10.00'
FIRST FLOOR (T.O.S.)
10.00'
1
A-5.4
1
A-5.3
2
A-5.3
2
A-5.2
1
A-5.5
BATH #5W.I.C.
MASTER W.I.C.
GAME ROOMGREAT ROOMDINING ROOMKITCHENBUTLER'S
KITCHEN
GYM / OFFICE MASTER SUITE
11' - 3 5/8"1' - 3 1/8"10' - 8 1/4"1' - 1"5' - 11 7/8"1' - 0"11' - 6 3/4"11' - 9 1/4"11' - 3 5/8"1' - 3 1/8"9' - 0"1' - 3 1/8"7' - 6"1' - 0"11' - 6 3/4"10' - 8 1/4"1' - 1"5' - 11 7/8"1
2
7
6
5
3 :1 2 3:12
10 :12
1
0:12
3:1 2
3:12
9:12
7 :1 2
292628
1 51
44
41
PLPL2' - 0 1/2"2' - 3 3/4"SOFFIT10' - 2 1/8"10' - 8 1/8"SOFFIT10' - 6 5/8"19' - 4 1/4"SOFFIT9' - 6 5/8"9' - 2 7/8"9' - 0"AD-1
21
AD-1
6
A-3.0
D
7
7
9
10
10
117
12
13
7 12
1313
8
7
14
15
13
16
17 11
18
8
11
13
13
111817
14
19
19
19
Name
Elevation
A101
1
SIM
Room name
150 SF
101
1i
?
90 00' 00"
Distance
N E
1
1
A101
SIM
R @ 7 1/2"20
1i
NORTH ARROW
PROPERTY LINE TAG
SECTION INDICATOR
ROOM TAG (NAME / AREA)
CALL-OUT TAG
ELEVATION INDICATOR
KEYNOTE TAG
WINDOW TAG
DOOR TAG
WALL TAG
REVISION FLAG
STAIR TAG (NO. OF RISER & HEIGHT)
JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT
A-5.1
7/19/19
201837BUILDING SECTIONSSTUPIN RESIDENCE
STUPIN RESIDENCEAMDREW & JULIE STUPINC/O. COASTLINE REALESTATE INVESTMENTS215TH STREETHUNTINGTON BEACHCA 92648CDP
3322 VIA LIDO, NEWPORT BEACH, CA 92663JUSTIN JONHSTON
KEYNOTE LEGEND
1 ROOF RAFTERS - REF. STRUCT.
2 FLOOR JOISTS - REF. STRUCT.
3 DECK FRAMING - REF. STRUCT.
4 EXTERIOR GUARDRAIL - MIN. 42" HEIGHT - 4" MAX. SPHERE OPENING, REF. DTL. 9 & 13/AD-1
5 RESIDENTIAL HYDRAULIC ELEVATOR - 'WAUPACA ELEVATOR COMPANY' OR EQUIV., SHAFT SIZE APPX. = 60"
X 68" CLEAR - PROVIDE SHOP DWGS. TO ARCH. PRIOR TO PURCHASE & INSTALLATION
6 CONCRETE FOOTING - REF. STRUCT.
7 FURNISHINGS - AS SELECTED
8 DECORATIVE PENDANT LIGHT FIXTURE TO BE HIGH EFFICACY, REF. NOTE #5 OF ELECTRICAL NOTES
9 BATHTUB - FREE-STANDING, AS SELECTED (VERIFY LOC'N. OF FIXTURES W/. OWNER)
10 SHELF AND POLE - BUILT IN, FINISH AS SEL.
11 COUNTERTOP - AS SELECTED
12 WINE RACKS - AS SELECTED - PROVIDE SHOP DWGS. TO ARCH & OWNER
13 UPPER CABINET - BUILT-IN, FINISH AS SEL.
14 A/C. CONDENSER UNIT - SIZE TBD - PROVIDE POWER AND SOUND DAMPENING PAD AS REQ'D. (SOUND ATT.
REQ'D. PER SECTION 10.26.045 NBMC UNDER SEPARATE PERMIT)
15 KITCHEN EXHAUST HOOD - PROVIDE VENT TO OUTDOOR W/. MIN. RATE OF 100 CFM - INSTALL & PROVIDE
POWER PER MFGR'S. INSTRS.
16 RANGE - VERIFY APPLIANCE W/. OWNER - PROVIDE HOOD CAPABLE OF 100 CFM MIN. (VERIFY W/. MFGR.)
17 KITCHEN SINK - AS SELECTED
18 BASE CABINET - BUILT-IN, FINISH AS SEL.
19 FIREPLACE - PREFABRICATED, GAS ONLY, 'ASTRIA' GEORGIAN FIREPLACE - SIZE PER PLAN (ANSI Z21.60), 36"
SINGLE SIDED CONFIGURATIONS [DTL. 22/AD-1] (FACTORY BUILT FIREPLACES, CHIMNEYS, AND ALL OTHER
COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING AND MFG'R.
INSTALLATION INSTRUCTIONS. GASEOUS FUEL BURNING PAN MUST BE PERMANENTLY ANCHORED TO THE
FIREBOX. FIREPLACE MUST COMPLY W/. THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES.)
20 WALL MOUNTED LIGHT FIXTURE, SCONCE
NO. REVISION DATE
1/4" = 1'-0"1 LONGITUDINAL SECTION
1/4" = 1'-0"2 LONGITUDINAL SECTION
ANNOTATION LEGENDA
43
SECOND FLOOR PLATE (TYP.)
21.30'
SECOND FLOOR PLATE (TYP.)
21.30'
SECOND FLOOR T.O.S. (TYP.)
22.56'
SECOND FLOOR T.O.S. (TYP.)
22.56'
ROOF PLATE (TYP.)
40.32'
ROOF PLATE (TYP.)
40.32'
GRADE PLANE
10.12'
GRADE PLANE
10.12'
MAX. FLAT ROOF
38.12'
MAX. FLAT ROOF
38.12'
MAX. RIDGE
43.12'
MAX. RIDGE
43.12'
THIRD FLOOR PLATE (TYP.)
31.56'
THIRD FLOOR PLATE (TYP.)
31.56'
2
A-5.4
FIRST FLOOR (T.O.S.)
10.00'
FIRST FLOOR (T.O.S.)
10.00'
1
A-5.4
1
A-5.3
2
A-5.3
2
A-5.2
1
A-5.5
LOGGIAPATIO
GYM / OFFICE MASTER BATH
11' - 3 5/8"1' - 3 1/8"9' - 0"8' - 9 1/8"1
2
3
4 :1 2 4:1210:12
10:12
3 :1 2
3:12
7 :1 2
8 :1 2
9 :1 2 9:12
9 :1 2
9:12
3:123:1 2
1718
7 6
89
17 16 15 14
46
5
1415 13
2628
PLPL1' - 11 1/2"8' - 11 7/8"14' - 10"AD-1
21
AD-1
15
A-3.0
D
14
AD-1
13
AD-1
85 5
9
9
102
11
12 2
16 16
1717
FIREBLOCKING AND DRAFTSTOPPING SHALL BE INSTALLED TO CUT OFF ALL CONCEALED DRAFT OPENINGS
(BOTH VERTICAL AND HORIZONTAL) AND SHALL FORM AN EFFECTIVE BARRIER BETWEEN FLOORS, BETWEEN A
TOP STORY AND A ROOF OR ATTIC SPACE, AND SHALL SUBDIVIDE ATTIC SPACES, CONCEALED ROOF SPACES
AND FLOOR-CEILING ASSEMBLIES. THE INTEGRITY OF ALL FIRE BLOCKS AND DRAFT STOPS SHALL BE
MAINTAINED.
FIRE BLOCKS.
FIREBLOCKING SHALL BE PROVIDED IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING
FURRED SPACES, AT THE CEILING AND FLOOR LEVELS AND AT 10-FOOT INTERVALS BOTH VERTICAL AND
HORIZONTAL.
FIRE BLOCK CONSTRUCTION. FIREBLOCKING SHALL CONSIST OF 2 INCHES NOMINAL LUMBER. FIRE BLOCKS MAY
ALSO BE OF GYPSUM BOARD, CEMENT FIBER BOARD, BATTS OR BLANKETS OF MINERAL OR GLASS FIBER, OR
OTHER APPROVED MATERIALS INSTALLED IN SUCH A MANNER AS TO BE SECURELY RETAINED IN PLACE. LOOSE-
FILL INSULATION MATERIAL SHALL NOT BE USED.
WALLS HAVING PARALLEL OR STAGGERED STUDS FOR SOUND-TRANSMISSION CONTROL SHALL HAVE FIRE
BLOCKS OF BATTS OR BLANKETS OF MINERAL OR GLASS FIBER OR OTHER APPROVED FLEXIBLE MATERIALS.
DRAFT STOPS.
DRAFTSTOPPING SHALL BE PROVIDED IN THE LOCATIONS SET FORTH IN THIS SECTION.
FLOOR-CEILING ASSEMBLIES.
DRAFT STOPS SHALL BE INSTALLED IN FLOOR-CEILING ASSEMBLIES OF THE BUILDING. SUCH DRAFT STOPS
SHALL BE IN LINE WITH WALLS SEPARATING INDIVIDUAL DWELLING UNITS FROM EACH OTHER AND FROM OTHER
AREAS.
ATTICS.
DRAFT STOPS SHALL BE INSTALLED IN THE ATTICS, MANSARDS, OVERHANGS, FALSE FRONTS SET OUT FROM
WALLS AND SIMILAR CONCEALED SPACES OF THIS BUILDING. SUCH DRAFT STOPS SHALL BE ABOVE AND IN LINE
WITH THE WALLS SEPARATING INDIVIDUAL DWELLING UNITS FROM EACH OTHER AND FROM OTHER USES.
DRAFT STOP CONSTRUCTION.
DRAFTSTOPPING MATERIALS SHALL NOT BE LESS THAN ½-INCH GYPSUM BOARD, 3/8-INCH WOOD STRUCTURAL
PANEL, 3/8-INCH TYPE 2-M PARTICLEBOARD OR OTHER APPROVED MATERIALS ADEQUATELY SUPPORTED.
OPENINGS IN THE PARTITIONS SHALL BE PROTECTED BY SELF-CLOSING DOORS WITH AUTOMATIC LATCHES
CONSTRUCTED AS REQUIRED FOR THE PARTITIONS.
FIRE-BLOCKING & DRAFT-STOP NOTE
INSULATION SCHEDULE:
EXTERIOR WALL:
2 x 4 CONST. = R-13 MIN.
2 x 6 CONST. OR LARGER =R-19
RAISED FLOOR:R-30 MIN.
ROOF:R-30
(REF. T-24 REPORT FOR MORE INFORMATION)
NOTE: PROVIDE BID FOR INSULATION OF ENTIRE HOME
NEW WALL -2 x 6 STUDS @ 16" O.C. U.N.O.
NEW WALL -2 x 4 STUDS @ 16" O.C. U.N.O.
WALL W/. STONE VENEER -2x STUDS @ 16" O.C. U.N.O.
CONCRETE RETAINING WALL -REF. STRUCTURAL
SEPARATION LEGEND
EXTERIOR FIRE RATED PARTITION REF. DTL. 5/AD-1
1 HR. FIRE RATED PARTITION REF. DTL. 7/AD-1
1 HR. FLOOR SYSTEM REF. DTL. 7/AD-1
INSULATED SYS. REF. INSULATION SCHEDULE THIS SHT.
B
SECOND FLOOR PLATE (TYP.)
21.30'
SECOND FLOOR PLATE (TYP.)
21.30'
ROOF PLATE (TYP.)
40.32'
ROOF PLATE (TYP.)
40.32'
GRADE PLANE
10.12'
GRADE PLANE
10.12'
MAX. FLAT ROOF
38.12'
MAX. FLAT ROOF
38.12'
MAX. RIDGE
43.12'
MAX. RIDGE
43.12'
THIRD FLOOR PLATE (TYP.)
31.56'
THIRD FLOOR PLATE (TYP.)
31.56'
THIRD FLOOR T.O.S. (TYP.)
32.82'
THIRD FLOOR T.O.S. (TYP.)
32.82'
GARAGE T.O.C.
10.50'
FIRST FLOOR (T.O.S.)
10.00'
FIRST FLOOR (T.O.S.)
10.00'
1
A-5.1
2
A-5.1
2
A-5.0
1
A-5.0
1
A-5.2
GYM / OFFICEBATH #4BATH #2BEDROOM #2
FAMILY ROOM
2-CAR GARAGE 2
BUTLER'S
KITCHEN
PATIO
SECOND FLOOR FINISH
22.69'
SECOND FLOOR FINISH
22.69'7' - 6"1' - 3 1/8"8' - 10 1/2"1' - 4 5/8"11' - 3 5/8"10' - 1 5/8"12' - 8 1/4"7' - 6"1' - 3 1/8"8' - 10 1/2"1' - 4 5/8"10' - 9 5/8"6"10' - 1 5/8"12' - 8 1/4"4
3
5
6
2
7
SLOPE PER CIVIL POOL
(BY SEP. PERMIT)
R
5' - 3 1/4
"
4:12
6 :1 2
7
40 4544
10
ABV. F.F.42" MIN.PL PL
A-3.0
F
AD-1
15
8
AD-1
7
AD-1
7
AD-1
2
9
5 13 14 3 15
2
8' - 6 5/8"2536
Name
Elevation
A101
1 SIM
Room name
150 SF
101
1i
?
90 00' 00"
Distance
N E
1
1
A101
SIM
R @ 7 1/2"20
1i
NORTH ARROW
PROPERTY LINE TAG
SECTION INDICATOR
ROOM TAG (NAME / AREA)
CALL-OUT TAG
ELEVATION INDICATOR
KEYNOTE TAG
WINDOW TAG
DOOR TAG
WALL TAG
REVISION FLAG
STAIR TAG (NO. OF RISER & HEIGHT)
JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT
A-5.2
7/19/19
201837BUILDING SECTIONSSTUPIN RESIDENCE
STUPIN RESIDENCEAMDREW & JULIE STUPINC/O. COASTLINE REALESTATE INVESTMENTS215TH STREETHUNTINGTON BEACHCA 92648CDP
3322 VIA LIDO, NEWPORT BEACH, CA 92663JUSTIN JONHSTON
NO. REVISION DATE
1/4" = 1'-0"1 LONGITUDINAL SECTION
KEYNOTE LEGEND
1 FLOOR JOISTS - REF. STRUCT.
2 FURNISHINGS - AS SELECTED
3 BASE CABINET - BUILT-IN, FINISH AS SEL.
4 CONCRETE FOOTING - REF. STRUCT.
5 COUNTERTOP - AS SELECTED
6 UPPER CABINET - BUILT-IN, FINISH AS SEL.
7 ROOF RAFTERS - REF. STRUCT.
8 BATHTUB - FREE-STANDING, AS SELECTED (VERIFY LOC'N. OF FIXTURES W/. OWNER)
9 WALL MOUNTED LIGHT FIXTURE, SCONCE
10 FIREPLACE - PREFABRICATED, GAS ONLY, 'ASTRIA' GEORGIAN FIREPLACE - SIZE PER PLAN (ANSI Z21.60),
36" SINGLE SIDED CONFIGURATIONS [DTL. 22/AD-1] (FACTORY BUILT FIREPLACES, CHIMNEYS, AND ALL
OTHER COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING AND MFG'R.
INSTALLATION INSTRUCTIONS. GASEOUS FUEL BURNING PAN MUST BE PERMANENTLY ANCHORED TO THE
FIREBOX. FIREPLACE MUST COMPLY W/. THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES.)
11 BAR SINK - AS SELECTED
12 BBQ AS SELECTED. - PROVIDE GAS S.O. & POWER AS REQ'D. BY MFGR. - VERIFY W/. OWNER
13 SINK - AS SELECTED (VERIFY COUNTER OR WALL MOUNT FIXTURES W/. OWNER)
14
15 WORKOUT/GYM EQUIPMENT
16 EXTERIOR LIGHTING - TO BE HIGH EFFICIENCY, REF. NOTE #33 OF ELECTRICAL NOTES
17 COLLECTOR TO MATCH DOWNSPOUT AND GUTTER MAT., REF. AMT. SCHED. A/A-4.0 - ARCH. TOP APPV.
1/4" = 1'-0"2 TRANSVERSE SECTION
ANNOTATION LEGENDA
44
FIREBLOCKING AND DRAFTSTOPPING SHALL BE INSTALLED TO CUT OFF ALL CONCEALED DRAFT OPENINGS
(BOTH VERTICAL AND HORIZONTAL) AND SHALL FORM AN EFFECTIVE BARRIER BETWEEN FLOORS, BETWEEN A
TOP STORY AND A ROOF OR ATTIC SPACE, AND SHALL SUBDIVIDE ATTIC SPACES, CONCEALED ROOF SPACES
AND FLOOR-CEILING ASSEMBLIES. THE INTEGRITY OF ALL FIRE BLOCKS AND DRAFT STOPS SHALL BE
MAINTAINED.
FIRE BLOCKS.
FIREBLOCKING SHALL BE PROVIDED IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING
FURRED SPACES, AT THE CEILING AND FLOOR LEVELS AND AT 10-FOOT INTERVALS BOTH VERTICAL AND
HORIZONTAL.
FIRE BLOCK CONSTRUCTION. FIREBLOCKING SHALL CONSIST OF 2 INCHES NOMINAL LUMBER. FIRE BLOCKS MAY
ALSO BE OF GYPSUM BOARD, CEMENT FIBER BOARD, BATTS OR BLANKETS OF MINERAL OR GLASS FIBER, OR
OTHER APPROVED MATERIALS INSTALLED IN SUCH A MANNER AS TO BE SECURELY RETAINED IN PLACE. LOOSE-
FILL INSULATION MATERIAL SHALL NOT BE USED.
WALLS HAVING PARALLEL OR STAGGERED STUDS FOR SOUND-TRANSMISSION CONTROL SHALL HAVE FIRE
BLOCKS OF BATTS OR BLANKETS OF MINERAL OR GLASS FIBER OR OTHER APPROVED FLEXIBLE MATERIALS.
DRAFT STOPS.
DRAFTSTOPPING SHALL BE PROVIDED IN THE LOCATIONS SET FORTH IN THIS SECTION.
FLOOR-CEILING ASSEMBLIES.
DRAFT STOPS SHALL BE INSTALLED IN FLOOR-CEILING ASSEMBLIES OF THE BUILDING. SUCH DRAFT STOPS
SHALL BE IN LINE WITH WALLS SEPARATING INDIVIDUAL DWELLING UNITS FROM EACH OTHER AND FROM OTHER
AREAS.
ATTICS.
DRAFT STOPS SHALL BE INSTALLED IN THE ATTICS, MANSARDS, OVERHANGS, FALSE FRONTS SET OUT FROM
WALLS AND SIMILAR CONCEALED SPACES OF THIS BUILDING. SUCH DRAFT STOPS SHALL BE ABOVE AND IN LINE
WITH THE WALLS SEPARATING INDIVIDUAL DWELLING UNITS FROM EACH OTHER AND FROM OTHER USES.
DRAFT STOP CONSTRUCTION.
DRAFTSTOPPING MATERIALS SHALL NOT BE LESS THAN ½-INCH GYPSUM BOARD, 3/8-INCH WOOD STRUCTURAL
PANEL, 3/8-INCH TYPE 2-M PARTICLEBOARD OR OTHER APPROVED MATERIALS ADEQUATELY SUPPORTED.
OPENINGS IN THE PARTITIONS SHALL BE PROTECTED BY SELF-CLOSING DOORS WITH AUTOMATIC LATCHES
CONSTRUCTED AS REQUIRED FOR THE PARTITIONS.
FIRE-BLOCKING & DRAFT-STOP NOTE
INSULATION SCHEDULE:
EXTERIOR WALL:
2 x 4 CONST. = R-13 MIN.
2 x 6 CONST. OR LARGER =R-19
RAISED FLOOR:R-30 MIN.
ROOF:R-30
(REF. T-24 REPORT FOR MORE INFORMATION)
NOTE: PROVIDE BID FOR INSULATION OF ENTIRE HOME
NEW WALL -2 x 6 STUDS @ 16" O.C. U.N.O.
NEW WALL -2 x 4 STUDS @ 16" O.C. U.N.O.
WALL W/. STONE VENEER -2x STUDS @ 16" O.C. U.N.O.
CONCRETE RETAINING WALL -REF. STRUCTURAL
SEPARATION LEGEND
EXTERIOR FIRE RATED PARTITION REF. DTL. 5/AD-1
1 HR. FIRE RATED PARTITION REF. DTL. 7/AD-1
1 HR. FLOOR SYSTEM REF. DTL. 7/AD-1
INSULATED SYS. REF. INSULATION SCHEDULE THIS SHT.
B
SECOND FLOOR PLATE (TYP.)
21.30'
SECOND FLOOR PLATE (TYP.)
21.30'
SECOND FLOOR T.O.S. (TYP.)
22.56'
SECOND FLOOR T.O.S. (TYP.)
22.56'
ROOF PLATE (TYP.)
40.32'
ROOF PLATE (TYP.)
40.32'
GRADE PLANE
10.12'
GRADE PLANE
10.12'
MAX. FLAT ROOF
38.12'
MAX. FLAT ROOF
38.12'
MAX. RIDGE
43.12'
MAX. RIDGE
43.12'
THIRD FLOOR PLATE (TYP.)
31.56'
THIRD FLOOR PLATE (TYP.)
31.56'
THIRD FLOOR T.O.S. (TYP.)
32.82'
THIRD FLOOR T.O.S. (TYP.)
32.82'
GARAGE T.O.C.
10.50'
GARAGE T.O.C.
10.50'
FIRST FLOOR (T.O.S.)
10.00'
FIRST FLOOR (T.O.S.)
10.00'
1
A-5.1
2
A-5.1
2
A-5.0
1
A-5.0
1
A-5.2
FAMILY ROOM
GYM / OFFICE BEDROOM #2
2-CAR GARAGE 2
KITCHEN
PATIO
6"10' - 9 5/8"1' - 3 1/8"9' - 0"1' - 3 1/8"7' - 6"12' - 6 3/4"10' - 3 1/8"6"10' - 9 5/8"1' - 3 1/8"9' - 0"1' - 3 1/8"7' - 6"12' - 6 3/4"10' - 3 1/8"1
2
3
4
5
6
6
SLOPE PER CIVIL
POOL
(BY SEP. PERMIT)
103231
10
1918
27 28
47 48 49
9
1
2:1
2
3:123:1 2
4 :1 2
ABV. F.F.42" MIN.ABV. F.F.42" MIN.PLPL
A-3.0
F
AD-1
15
7
AD-1
7
AD-1
8
AD-1 8' - 6 5/8"9' - 4"8 6
9 1011 12
13
ENTRY FLOOR (T.O.S.)
11.00'
SECOND FLOOR PLATE (TYP.)
21.30'
SECOND FLOOR PLATE (TYP.)
21.30'
SECOND FLOOR T.O.S. (TYP.)
22.56'
SECOND FLOOR T.O.S. (TYP.)
22.56'
ROOF PLATE (TYP.)
40.32'
ROOF PLATE (TYP.)
40.32'
GRADE PLANE
10.12'
GRADE PLANE
10.12'
MAX. FLAT ROOF
38.12'
MAX. FLAT ROOF
38.12'
MAX. RIDGE
43.12'
MAX. RIDGE
43.12'
THIRD FLOOR PLATE (TYP.)
31.56'
THIRD FLOOR T.O.S. (TYP.)
32.82'
ROOF DECK PLATE
33.25'
ROOF DECK T.O.S.
34.33'
FIRST FLOOR (T.O.S.)
10.00'
FIRST FLOOR (T.O.S.)
10.00'
1
A-5.1
2
A-5.1
2
A-5.0
1
A-5.0
1
A-5.2
MASTER SUITE
ELEVATOR
ELEVATOR
LAUNDRY
POWDERFOYERELEVATOR
DINING ROOM11' - 3 5/8"1' - 3 1/8"10' - 8 1/4"1' - 1"5' - 11 7/8"1' - 0"10' - 3 5/8"1' - 3 1/8"9' - 0"1' - 3 1/8"7' - 6"12' - 6 3/4"10' - 3 1/8"12' - 6 3/4"11' - 9 1/4"5
6
6
1
6
7
2
4
POOL
(BY SEP. PERMIT)
15
12
1918
4045 44
48
10 :12
3 :1 2 3:12
1
2:1
2
6:12
7 12
ABV. F.F.42" MIN.ABV. F.F.42" MIN.ABV. F.F.42" MIN.PLPL
A-3.0
D
A-3.0
FAD-1
13
AD-1
15
10' - 0 5/8"10 66
1415
1611 11' - 4 3/8"Name
Elevation
A101
1 SIM
Room name
150 SF
101
1i
?
90 00' 00"
Distance
N E
1
1
A101
SIM
R @ 7 1/2"20
1i
NORTH ARROW
PROPERTY LINE TAG
SECTION INDICATOR
ROOM TAG (NAME / AREA)
CALL-OUT TAG
ELEVATION INDICATOR
KEYNOTE TAG
WINDOW TAG
DOOR TAG
WALL TAG
REVISION FLAG
STAIR TAG (NO. OF RISER & HEIGHT)
JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT
A-5.3
7/19/19
201837BUILDING SECTIONSSTUPIN RESIDENCE
STUPIN RESIDENCEAMDREW & JULIE STUPINC/O. COASTLINE REALESTATE INVESTMENTS215TH STREETHUNTINGTON BEACHCA 92648CDP
3322 VIA LIDO, NEWPORT BEACH, CA 92663JUSTIN JONHSTON
NO. REVISION DATE
KEYNOTE LEGEND
1 ROOF RAFTERS - REF. STRUCT.
2 FLOOR JOISTS - REF. STRUCT.
3 RESIDENTIAL HYDRAULIC ELEVATOR - 'WAUPACA ELEVATOR COMPANY' OR EQUIV., SHAFT SIZE APPX. = 60"
X 68" CLEAR - PROVIDE SHOP DWGS. TO ARCH. PRIOR TO PURCHASE & INSTALLATION
4 CONCRETE FOOTING - REF. STRUCT.
5 EXTERIOR GLASS GUARDRAIL - MIN. 42" HEIGHT - 4" MAX. SPHERE OPENING, REF. DTL. 9 & 13/AD-1
6 FURNISHINGS - AS SELECTED
7 DECK FRAMING - REF. STRUCT.
8 WORKOUT/GYM EQUIPMENT
9 BASE CABINET - BUILT-IN, FINISH AS SEL.
10 COUNTERTOP - AS SELECTED
11 UPPER CABINET - BUILT-IN, FINISH AS SEL.
12 RANGE - VERIFY APPLIANCE W/. OWNER - PROVIDE HOOD CAPABLE OF 100 CFM MIN. (VERIFY W/. MFGR.)
13 (N.) CMU PROPERTY LINE WALL W/. STUCCO FINISH - PAINT AS SELECTED (MAX. 6' ABV. N.G., 42" MAX @
F.Y.S.B) [WALL AND FOOTING ON OWNER'S SIDE]
14 DRYER - PROVIDE 4" MIN. DIA. DUCT, 14' MAX. LENGTH INCLUDING (2) 90 DEGREE ELBOWS, DEDUCT TWO(2)
FEET FOR EACH 90 DEGREE ELBOW IN EXCESS OF TWO(2) (CMC 504.3.2)
15 WASHER AND/OR DRYER - PROVIDE HOOK-UPS, POWER, INSTALL PAN & DRAIN UNDER WASHER (TYP.) -
G.C. TO VERIFY LOC'N. & SIZE & DRYER VENT 14' MAX. LENGTH (CMC 504.3.2) PROVIDE GAS STUB-OUT
16 SINK - AS SELECTED (VERIFY COUNTER OR WALL MOUNT FIXTURES W/. OWNER)
1/4" = 1'-0"1 TRANSVERSE SECTION
1/4" = 1'-0"2 TRANSVERSE SECTION
ANNOTATION LEGENDA
45
INSULATION SCHEDULE:
EXTERIOR WALL:
2 x 4 CONST. = R-13 MIN.
2 x 6 CONST. OR LARGER =R-19
RAISED FLOOR:R-30 MIN.
ROOF:R-30
(REF. T-24 REPORT FOR MORE INFORMATION)
NOTE: PROVIDE BID FOR INSULATION OF ENTIRE HOME
NEW WALL -2 x 6 STUDS @ 16" O.C. U.N.O.
NEW WALL -2 x 4 STUDS @ 16" O.C. U.N.O.
WALL W/. STONE VENEER -2x STUDS @ 16" O.C. U.N.O.
CONCRETE RETAINING WALL -REF. STRUCTURAL
SEPARATION LEGEND
EXTERIOR FIRE RATED PARTITION REF. DTL. 5/AD-1
1 HR. FIRE RATED PARTITION REF. DTL. 7/AD-1
1 HR. FLOOR SYSTEM REF. DTL. 7/AD-1
INSULATED SYS. REF. INSULATION SCHEDULE THIS SHT.
B
FIREBLOCKING AND DRAFTSTOPPING SHALL BE INSTALLED TO CUT OFF ALL CONCEALED DRAFT OPENINGS
(BOTH VERTICAL AND HORIZONTAL) AND SHALL FORM AN EFFECTIVE BARRIER BETWEEN FLOORS, BETWEEN A
TOP STORY AND A ROOF OR ATTIC SPACE, AND SHALL SUBDIVIDE ATTIC SPACES, CONCEALED ROOF SPACES
AND FLOOR-CEILING ASSEMBLIES. THE INTEGRITY OF ALL FIRE BLOCKS AND DRAFT STOPS SHALL BE
MAINTAINED.
FIRE BLOCKS.
FIREBLOCKING SHALL BE PROVIDED IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING
FURRED SPACES, AT THE CEILING AND FLOOR LEVELS AND AT 10-FOOT INTERVALS BOTH VERTICAL AND
HORIZONTAL.
FIRE BLOCK CONSTRUCTION. FIREBLOCKING SHALL CONSIST OF 2 INCHES NOMINAL LUMBER. FIRE BLOCKS MAY
ALSO BE OF GYPSUM BOARD, CEMENT FIBER BOARD, BATTS OR BLANKETS OF MINERAL OR GLASS FIBER, OR
OTHER APPROVED MATERIALS INSTALLED IN SUCH A MANNER AS TO BE SECURELY RETAINED IN PLACE. LOOSE-
FILL INSULATION MATERIAL SHALL NOT BE USED.
WALLS HAVING PARALLEL OR STAGGERED STUDS FOR SOUND-TRANSMISSION CONTROL SHALL HAVE FIRE
BLOCKS OF BATTS OR BLANKETS OF MINERAL OR GLASS FIBER OR OTHER APPROVED FLEXIBLE MATERIALS.
DRAFT STOPS.
DRAFTSTOPPING SHALL BE PROVIDED IN THE LOCATIONS SET FORTH IN THIS SECTION.
FLOOR-CEILING ASSEMBLIES.
DRAFT STOPS SHALL BE INSTALLED IN FLOOR-CEILING ASSEMBLIES OF THE BUILDING. SUCH DRAFT STOPS
SHALL BE IN LINE WITH WALLS SEPARATING INDIVIDUAL DWELLING UNITS FROM EACH OTHER AND FROM OTHER
AREAS.
ATTICS.
DRAFT STOPS SHALL BE INSTALLED IN THE ATTICS, MANSARDS, OVERHANGS, FALSE FRONTS SET OUT FROM
WALLS AND SIMILAR CONCEALED SPACES OF THIS BUILDING. SUCH DRAFT STOPS SHALL BE ABOVE AND IN LINE
WITH THE WALLS SEPARATING INDIVIDUAL DWELLING UNITS FROM EACH OTHER AND FROM OTHER USES.
DRAFT STOP CONSTRUCTION.
DRAFTSTOPPING MATERIALS SHALL NOT BE LESS THAN ½-INCH GYPSUM BOARD, 3/8-INCH WOOD STRUCTURAL
PANEL, 3/8-INCH TYPE 2-M PARTICLEBOARD OR OTHER APPROVED MATERIALS ADEQUATELY SUPPORTED.
OPENINGS IN THE PARTITIONS SHALL BE PROTECTED BY SELF-CLOSING DOORS WITH AUTOMATIC LATCHES
CONSTRUCTED AS REQUIRED FOR THE PARTITIONS.
FIRE-BLOCKING & DRAFT-STOP NOTE
ENTRY FLOOR (T.O.S.)
11.00'
SECOND FLOOR PLATE (TYP.)
21.30'
SECOND FLOOR PLATE (TYP.)
21.30'
SECOND FLOOR T.O.S. (TYP.)
22.56'
SECOND FLOOR T.O.S. (TYP.)
22.56'
ROOF PLATE (TYP.)
40.32'
ROOF PLATE (TYP.)
40.32'
GRADE PLANE
10.12'
GRADE PLANE
10.12'
MAX. FLAT ROOF
38.12'
MAX. FLAT ROOF
38.12'
MAX. RIDGE
43.12'
MAX. RIDGE
43.12'
THIRD FLOOR PLATE (TYP.)
31.56'
THIRD FLOOR T.O.S. (TYP.)
32.82'
ROOF DECK PLATE
33.25'
ROOF DECK T.O.S.
34.33'
FIRST FLOOR (T.O.S.)
10.00'
FIRST FLOOR (T.O.S.)
10.00'
1
A-5.1
2
A-5.1
2
A-5.0
1
A-5.0
1
A-5.2
MASTER SUITE
GREAT ROOM
FOYER
11' - 3 5/8"1' - 3 1/8"10' - 8 1/4"1' - 1"5' - 11 7/8"12' - 6 3/4"11' - 9 1/4"1' - 0"10' - 3 5/8"1' - 3 1/8"9' - 0"1' - 3 1/8"7' - 6"12' - 6 3/4"10' - 3 1/8"1
2
3
4
5
4
4
6
7
5
POOL
(BY SEP. PERMIT)
12
1918
4045 44 48
7 10 :12
3 :1 2 3:12
1
2:1
2
6:12
ABV. F.F.42" MIN.ABV. F.F.42" MIN.ABV. F.F.42" MIN.ABV. F.F.42" MIN.ABV. F.F.42" MIN.PLPL
A-3.0
D
A-3.0
FAD-1
13
AD-1
14
AD-1
4
AD-1
4
4
4410' - 0 5/8"11' - 5 7/8"ENTRY FLOOR (T.O.S.)
11.00'
SECOND FLOOR PLATE (TYP.)
21.30'
SECOND FLOOR PLATE (TYP.)
21.30'
SECOND FLOOR T.O.S. (TYP.)
22.56'
SECOND FLOOR T.O.S. (TYP.)
22.56'
ROOF PLATE (TYP.)
40.32'
ROOF PLATE (TYP.)
40.32'
GRADE PLANE
10.12'
GRADE PLANE
10.12'
MAX. FLAT ROOF
38.12'
MAX. FLAT ROOF
38.12'
MAX. RIDGE
43.12'
MAX. RIDGE
43.12'
THIRD FLOOR PLATE (TYP.)
31.56'
THIRD FLOOR T.O.S. (TYP.)
32.82'
ROOF DECK PLATE
33.25'
ROOF DECK T.O.S.
34.33'
FIRST FLOOR (T.O.S.)
10.00'
1
A-5.1
2
A-5.1
2
A-5.0
1
A-5.0
1
A-5.2
STAIRS
STAIRS
STAIRS
MASTER SUITE
GREAT ROOM7' - 6"1' - 3 1/8"9' - 0"1' - 3 1/8"10' - 3 5/8"10' - 3 1/8"11' - 6 3/4"5' - 11 7/8"1' - 1"10' - 8 1/4"1' - 3 1/8"11' - 3 5/8"11' - 9 1/4"12' - 6 3/4"1' - 6 1/8"5
38
9
10
4
11
12
13
POOL
(BY SEP. PERMIT)
16
43
6
30
37
4243
3:123:1 2
12:1210:1
2
6 :1 2
1
ABV. F.F.42" MIN.36" TYP.34" - 38"ABV. F.F.42" MIN.ABV. F.F.42" MIN.TYP.7 3/4"TYP.
11"
PL PL
AD-1
13
AD-1
14
A-3.0
D
A-3.0
F
AD-1
4
9' - 4"11' - 5 7/8"15' - 7 1/4"SOFFIT10' - 0 5/8"94
14
4
4
14
14
Name
Elevation
A101
1 SIM
Room name
150 SF
101
1i
?
90 00' 00"
Distance
N E
1
1
A101
SIM
R @ 7 1/2"20
1i
NORTH ARROW
PROPERTY LINE TAG
SECTION INDICATOR
ROOM TAG (NAME / AREA)
CALL-OUT TAG
ELEVATION INDICATOR
KEYNOTE TAG
WINDOW TAG
DOOR TAG
WALL TAG
REVISION FLAG
STAIR TAG (NO. OF RISER & HEIGHT)
JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT
A-5.4
7/19/19
201837BUILDING SECTIONSSTUPIN RESIDENCE
STUPIN RESIDENCEAMDREW & JULIE STUPINC/O. COASTLINE REALESTATE INVESTMENTS215TH STREETHUNTINGTON BEACHCA 92648CDP
3322 VIA LIDO, NEWPORT BEACH, CA 92663JUSTIN JONHSTON
NO. REVISION DATE
KEYNOTE LEGEND
1 EXTERIOR GLASS GUARDRAIL - MIN. 42" HEIGHT - 4" MAX. SPHERE OPENING, REF. DTL. 9 & 13/AD-1
2 DECK FRAMING - REF. STRUCT.
3 FLOOR JOISTS - REF. STRUCT.
4 FURNISHINGS - AS SELECTED
5 ROOF RAFTERS - REF. STRUCT.
6 RESIDENTIAL HYDRAULIC ELEVATOR - 'WAUPACA ELEVATOR COMPANY' OR EQUIV., SHAFT SIZE APPX. =
60" X 68" CLEAR - PROVIDE SHOP DWGS. TO ARCH. PRIOR TO PURCHASE & INSTALLATION
7 CONCRETE FOOTING - REF. STRUCT.
8 BASE CABINET - BUILT-IN, FINISH AS SEL.
9 COUNTERTOP - AS SELECTED
10 UPPER CABINET - BUILT-IN, FINISH AS SEL.
11 HANDRAIL - 34" - 38" ABOVE STAIR NOSING (36" U.N.O.) - MATERIAL AS SELECTED, REF. DTLS. 2, 4/AD-1
12 INTERIOR GUARDRAIL - MIN. 42" HIGH - MATERIAL AS SELECTED, <4" MAX. SPHERE OPENING, REF. DTL.
4/AD-1
13 STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS
THAN 1 FOOT CANDLE (CBC 1205.4) REF. DTL. 3/AD-1
14 FIREPLACE - PREFABRICATED, GAS ONLY, 'ASTRIA' GEORGIAN FIREPLACE - SIZE PER PLAN (ANSI Z21.60),
36" SINGLE SIDED CONFIGURATIONS [DTL. 22/AD-1] (FACTORY BUILT FIREPLACES, CHIMNEYS, AND ALL
OTHER COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING AND
MFG'R. INSTALLATION INSTRUCTIONS. GASEOUS FUEL BURNING PAN MUST BE PERMANENTLY ANCHORED
TO THE FIREBOX. FIREPLACE MUST COMPLY W/. THE CALIFORNIA ENERGY STANDARDS MANDATORY
MEASURES.)
1/4" = 1'-0"1 TRANSVERSE SECTION
1/4" = 1'-0"2 TRANSVERSE SECTION
ANNOTATION LEGENDA
46
FIREBLOCKING AND DRAFTSTOPPING SHALL BE INSTALLED TO CUT OFF ALL CONCEALED DRAFT OPENINGS
(BOTH VERTICAL AND HORIZONTAL) AND SHALL FORM AN EFFECTIVE BARRIER BETWEEN FLOORS, BETWEEN A
TOP STORY AND A ROOF OR ATTIC SPACE, AND SHALL SUBDIVIDE ATTIC SPACES, CONCEALED ROOF SPACES
AND FLOOR-CEILING ASSEMBLIES. THE INTEGRITY OF ALL FIRE BLOCKS AND DRAFT STOPS SHALL BE
MAINTAINED.
FIRE BLOCKS.
FIREBLOCKING SHALL BE PROVIDED IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING
FURRED SPACES, AT THE CEILING AND FLOOR LEVELS AND AT 10-FOOT INTERVALS BOTH VERTICAL AND
HORIZONTAL.
FIRE BLOCK CONSTRUCTION. FIREBLOCKING SHALL CONSIST OF 2 INCHES NOMINAL LUMBER. FIRE BLOCKS MAY
ALSO BE OF GYPSUM BOARD, CEMENT FIBER BOARD, BATTS OR BLANKETS OF MINERAL OR GLASS FIBER, OR
OTHER APPROVED MATERIALS INSTALLED IN SUCH A MANNER AS TO BE SECURELY RETAINED IN PLACE. LOOSE-
FILL INSULATION MATERIAL SHALL NOT BE USED.
WALLS HAVING PARALLEL OR STAGGERED STUDS FOR SOUND-TRANSMISSION CONTROL SHALL HAVE FIRE
BLOCKS OF BATTS OR BLANKETS OF MINERAL OR GLASS FIBER OR OTHER APPROVED FLEXIBLE MATERIALS.
DRAFT STOPS.
DRAFTSTOPPING SHALL BE PROVIDED IN THE LOCATIONS SET FORTH IN THIS SECTION.
FLOOR-CEILING ASSEMBLIES.
DRAFT STOPS SHALL BE INSTALLED IN FLOOR-CEILING ASSEMBLIES OF THE BUILDING. SUCH DRAFT STOPS
SHALL BE IN LINE WITH WALLS SEPARATING INDIVIDUAL DWELLING UNITS FROM EACH OTHER AND FROM OTHER
AREAS.
ATTICS.
DRAFT STOPS SHALL BE INSTALLED IN THE ATTICS, MANSARDS, OVERHANGS, FALSE FRONTS SET OUT FROM
WALLS AND SIMILAR CONCEALED SPACES OF THIS BUILDING. SUCH DRAFT STOPS SHALL BE ABOVE AND IN LINE
WITH THE WALLS SEPARATING INDIVIDUAL DWELLING UNITS FROM EACH OTHER AND FROM OTHER USES.
DRAFT STOP CONSTRUCTION.
DRAFTSTOPPING MATERIALS SHALL NOT BE LESS THAN ½-INCH GYPSUM BOARD, 3/8-INCH WOOD STRUCTURAL
PANEL, 3/8-INCH TYPE 2-M PARTICLEBOARD OR OTHER APPROVED MATERIALS ADEQUATELY SUPPORTED.
OPENINGS IN THE PARTITIONS SHALL BE PROTECTED BY SELF-CLOSING DOORS WITH AUTOMATIC LATCHES
CONSTRUCTED AS REQUIRED FOR THE PARTITIONS.
FIRE-BLOCKING & DRAFT-STOP NOTE
INSULATION SCHEDULE:
EXTERIOR WALL:
2 x 4 CONST. = R-13 MIN.
2 x 6 CONST. OR LARGER =R-19
RAISED FLOOR:R-30 MIN.
ROOF:R-30
(REF. T-24 REPORT FOR MORE INFORMATION)
NOTE: PROVIDE BID FOR INSULATION OF ENTIRE HOME
NEW WALL -2 x 6 STUDS @ 16" O.C. U.N.O.
NEW WALL -2 x 4 STUDS @ 16" O.C. U.N.O.
WALL W/. STONE VENEER -2x STUDS @ 16" O.C. U.N.O.
CONCRETE RETAINING WALL -REF. STRUCTURAL
SEPARATION LEGEND
EXTERIOR FIRE RATED PARTITION REF. DTL. 5/AD-1
1 HR. FIRE RATED PARTITION REF. DTL. 7/AD-1
1 HR. FLOOR SYSTEM REF. DTL. 7/AD-1
INSULATED SYS. REF. INSULATION SCHEDULE THIS SHT.
B
SECOND FLOOR PLATE (TYP.)
21.30'
SECOND FLOOR PLATE (TYP.)
21.30'
SECOND FLOOR T.O.S. (TYP.)
22.56'
SECOND FLOOR T.O.S. (TYP.)
22.56'
ROOF PLATE (TYP.)
40.32'
ROOF PLATE (TYP.)
40.32'
GRADE PLANE
10.12'
GRADE PLANE
10.12'
MAX. FLAT ROOF
38.12'
MAX. FLAT ROOF
38.12'
MAX. RIDGE
43.12'
MAX. RIDGE
43.12'
THIRD FLOOR PLATE (TYP.)
31.56'
THIRD FLOOR PLATE (TYP.)
31.56'
THIRD FLOOR T.O.S. (TYP.)
32.82'
THIRD FLOOR T.O.S. (TYP.)
32.82'
GARAGE T.O.C.
10.50'
FIRST FLOOR (T.O.S.)
10.00'
FIRST FLOOR (T.O.S.)
10.00'
1
A-5.1
2
A-5.1
2
A-5.0
1
A-5.0
1
A-5.2
BEDROOM #5 BATH #5
MASTER W.I.C.
BATH #3BEDROOM #3
GAME ROOM
2-CAR GARAGE 1 LOGGIA 7' - 6"1' - 3 1/8"9' - 0"1' - 3 1/8"11' - 3 5/8"10' - 3 1/8"12' - 6 3/4"7' - 6"1' - 3 1/8"9' - 0"1' - 3 1/8"10' - 9 5/8"6"10' - 3 1/8"12' - 6 3/4"MASTER BATH
1
2
3
456
7
SLOPE PER CIVIL
22213
38 39 40
4
36
10
9 11 13
1283
8:12
25
PL PL
A-3.0
F
A-3.0
F
A-3.0
D8' - 6 5/8"10' - 6 5/8"84
9
10
311
3
10
5 8 9
10 12
13
14
15 16
9
5 16 3
17
Name
Elevation
A101
1 SIM
Room name
150 SF
101
1i
?
90 00' 00"
Distance
N E
1
1
A101
SIM
R @ 7 1/2"20
1i
NORTH ARROW
PROPERTY LINE TAG
SECTION INDICATOR
ROOM TAG (NAME / AREA)
CALL-OUT TAG
ELEVATION INDICATOR
KEYNOTE TAG
WINDOW TAG
DOOR TAG
WALL TAG
REVISION FLAG
STAIR TAG (NO. OF RISER & HEIGHT)
JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT
A-5.5
7/19/19
201837BUILDING SECTIONSSTUPIN RESIDENCE
STUPIN RESIDENCEAMDREW & JULIE STUPINC/O. COASTLINE REALESTATE INVESTMENTS215TH STREETHUNTINGTON BEACHCA 92648CDP
3322 VIA LIDO, NEWPORT BEACH, CA 92663JUSTIN JONHSTON
NO. REVISION DATE
KEYNOTE LEGEND
1 SHELF AND POLE - BUILT IN, FINISH AS SEL.
2 FLOOR JOISTS - REF. STRUCT.
3 FURNISHINGS - AS SELECTED
4 BATHTUB - FREE-STANDING, AS SELECTED (VERIFY LOC'N. OF FIXTURES W/. OWNER)
5 COUNTERTOP - AS SELECTED
6 BASE CABINET - SINK UNIT, BUILT-IN, FINISH AS SEL.
7 ROOF RAFTERS - REF. STRUCT.
8 SINK - AS SELECTED (VERIFY COUNTER OR WALL MOUNT FIXTURES W/. OWNER)
9 BASE CABINET - BUILT-IN, FINISH AS SEL.
10 WALL MOUNTED LIGHT FIXTURE, SCONCE
11 DOWNSPOUT - COPPER/ALUMINUM W/. KYNAR FINISH OR EQUIV. - AS SEL. (ARCH. TO APPROVE)
12 DECORATIVE PENDANT LIGHT FIXTURE TO BE HIGH EFFICACY, REF. NOTE #5 OF ELECTRICAL NOTES
13 BAR SINK - AS SELECTED
14 TEMPERED GLASS ENCLOSURE - MIN. 3/8" THK., GLASS TO BE ETCH MARKED (FRAMELESS U.N.O.)
15 UPPER CABINET - BUILT-IN, FINISH AS SEL.
16 EGRESS GATE - 32" MIN. CLR. BY 42" MIN. TALL, SELF-CLOSING & SELF-LATCHING, SHALL BE RELEASABLE
OR REMOVEABLE FROM INSIDE W/O. USE OF KET OR TOOL, EXTERIOR RELEASE SHALL BE PROVIDED FOR
FIRE DEPARTMENT (R310)
17 FIREPLACE - PREFABRICATED, GAS ONLY, 'ASTRIA' GEORGIAN FIREPLACE - SIZE PER PLAN (ANSI Z21.60),
36" SINGLE SIDED CONFIGURATIONS [DTL. 22/AD-1] (FACTORY BUILT FIREPLACES, CHIMNEYS, AND ALL
OTHER COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING AND MFG'R.
INSTALLATION INSTRUCTIONS. GASEOUS FUEL BURNING PAN MUST BE PERMANENTLY ANCHORED TO THE
FIREBOX. FIREPLACE MUST COMPLY W/. THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES.)
1/4" = 1'-0"1 TRANSVERSE SECTION
ANNOTATION LEGENDA
47
From: Don and Judy Cole <lagunahouse@me.com>
Sent: Friday, September 06, 2019 3:52 PM
To: Westmoreland, Liz <LWestmoreland@newportbeachca.gov>
Cc: Dixon, Diane <ddixon@newportbeachca.gov>; Avery, Brad <bavery@newportbeachca.gov>;
Duffield, Duffy <dduffield@newportbeachca.gov>; Muldoon, Kevin
<kmuldoon@newportbeachca.gov>; Herdman, Jeff <jherdman@newportbeachca.gov>; Brenner, Joy
<JBrenner@newportbeachca.gov>; O'Neill, William <woneill@newportbeachca.gov>
Subject: Stupin Residence (PA2019-100)- Coastal Development Permit Hearing Thursday, Sept. 12
Liz,
Thank you for meeting with us yesterday to discuss the proposed project next door to
us. As we mentioned, we are unable to attend the hearing and we want to comment
on a few issues for the record.
First, there has not been proper notice for this hearing/project consistent with the
provisions of the Municipal Code. Our understanding is that when the application is
filed with the City, the applicant is required to post on the property a sign saying an
application is pending (see NBMC Sec. 21.50.080). This was never done. When and
if a hearing is scheduled, the City must post notice of the hearing on the property at
least 10 days in advance (NMBC Sec. 21.62.020.B.3). The applicant is responsible
for keeping them posted continuously, throughout the process (including until all
possibility of appeal has ended). While the sign was reportedly posted on Friday,
August 30, it was removed by someone sometime over the weekend. It was not there
when we returned home from our long weekend on Tuesday, September 3. If it were
not for a friend, we would not have been aware of the hearing. As soon as we heard,
we notified you that the notice was no longer up. There is still no posting up and it is
disappointing there is no enforcement of the code. Strangely, we also have not
received the mailed notice to date.
Second, is the issue of height. The relaxed height standard in the RM zone is
intended to allow construction of multi-unit structures.
We feel using the relaxed RM height standard to build a single family home is not
appropriate- especially on the water. In fact, the City is supposedly considering doing
something about tall single family homes in RM zones and it will be a subject of this
coming Tuesday's 4:00 p.m. City Council Study Session. Also related is the density
issue per the Coastal Land Use plan. While single family homes are allowed in RM
Zones, it should only be if they meet the density requirements. The City needs to be
consistent in the application of this requirement.
Based upon these issues, we request a continuance. Thank you again for your
consideration.
Don & Judy Cole
3326 Via Lido
Zoning Administrator - September 12, 2019
Item No. 2a Additional Materials Received
Stupin Residence Coastal Development Permit (PA2019-100)
Sept. 12, 2019, Zoning Administrator Agenda Comments
Comments submitted by: Jim Mosher ( jimmosher@yahoo.com ), 2210 Private Road, Newport Beach
92660 (949-548-6229)
Item 2. Stupin Residence Coastal Development Permit No. CD2019-
033 (PA2019-100)
I believe the draft resolution of approval contains at least one easily-corrected error in the
proposed legal description in Section 1.2 (handwritten page 8):
“The lots at 3312-3318, 3322, 3324 Via Lido are legally described as Lots 1 and 2 of Tract 1622,
in the City of Newport Beach, County of Orange, State of California, as per Map Recorded in
Book 47, Miscellaneous Maps, in the Office of the County Assessor of Said County. E, except
the Northwesterly 28 feet of said Lot 2. The property at 3322 and 3324 Via Lido is legally
described as Parcel 2 of PM2009-125, in the City of Newport Beach, County of Orange, State of
California, as per Map recorded in Book 373, Pages 21 & 22 or said Parcel Maps in the Office of
the County Recorder of Said County.”
[To explain, my understanding is Lots 1 and 2 of Tract 1622 were originally each 40 feet
wide. Combining the two, but taking away 28 feet leaves the 52 feet width of the currently 4-
unit 3312-3318 parcel which is what is being described in the first sentence. The currently 2-
unit 3322/3324 parcel – described in the second sentence – adds another 41.5 feet as
shown on handwritten page 24.]
In this connection, to avoid violation of the City’s prohibition against building a structure over lot
lines, it would appear the present CDP application must be accompanied by a separate
application for a lot merger. The California Supreme Court has decided in Pacific Palisades
Bowl Mobile Estates, LLC v. City of Los Angeles, 55 Cal.4th 783 (2012) that all subdivision in
the Coastal Zone – independent of whether it changes intensity of development in theory or
practice – requires a CDP. Even without that, this lot merger surely will require a CDP since its
clear purpose is to permit a very substantial reduction in the density of residential development
– and a reduction that would not be possible without it (from the six units currently existing to
just one).
In view of that, it does not seem proper to me to separate the construction proposal from the lot
merger proposal it will require. I hope this item will return with the whole proposal, not just a part
of it. Or has the lot merger already been approved?
Zoning Administrator - September 12, 2019
Item No. 2b Additional Materials Received
Stupin Residence Coastal Development Permit (PA2019-100)