Loading...
HomeMy WebLinkAboutExhibit D - Plans CSTAM_007_CD100 SITE NAME: CSTAM 007 SITE NUMBER: CRAN RLOS CSTAM 007 at&t PROJECT: CRAN/ SMALL CELL/ PICO USID: 213741 PACE: MRLOS051857 ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE E R I CS SON WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES.NOTHING IN THESE PLANS IS TO BE - IF USING IVx17"PLOT,DRAWING WILL BE HALF SCALE 330 COMMERCE,STE.200 CONSTRUCTED TO PERMIT WORK NOT CONFORMING TO THESE CODES. _ 11, I RVIN E,CA 92602 1. 2016 CALIFORNIA ADMINISTRATIVE CODE 1 2. 2016 CAL IFORNIA BUILDING CODE CONSTRUCTION DRAWING 3. 2016 CALIFORNIA ELECTRIC CODE No 4. 2016 CALIFORNIA MECHANICAL CODE 5. 2016 CALIFORNIA PLUMBING CODE at&t 6. ANY CALIFLOCAL BUILDING FIRE CODE THE FOLLOWING PARTIES HEREBY APPROVE AND ACCEPT THESE DOCUMENTS&AUTHORIZE 7. ANY LOCAL BUILDING CODE AMENDMENTS TO THE ABOVE THE SUBCONTRACTOR TO PROCEED WITH THE CONSTRUCTION DESCRIBED HEREIN.ALL 8. CITY/COUNTY ORDINANCES — DOCUMENTS ARE SUBJECT TO REVIEW BY THE LOCAL BUILDING DEPARTMENT 8 MAY IMPOSE �7 9. NEC,NATIONAL ELECTRIC CODE a CHANGES OR MODIFICATIONS. M S QU A R(•/ 10. CALIFORNIA TRAFFIC CONTROL LANE CLOSURES MUTCD `� POLE TYPE: (N) CONCRETE LIGHT POLE WIRELESS HANDICAP REQUIREMENTS: APPROVED BY: INITIALS: DATE: FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION.HANDICAPPED ACCESS 1 3 8 7 CALLE L L E A V A N Z A D O NOT REQUIRED IN ACCORDANCE WITH CALIFORNIA ADMINISTRATIVE STATE CODE SAN CLEMENTE CA 92673(949)391-6824 PART 2,TITLE 24,CHAPTER 1113,SECTION 11036. AT&T RF ENGINEER: CODE COMPLIANCE POLE ID #: 0902 AT&T OPERATIONS: SITE ACQUISITION MANAGER: THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION.A TECHNICIAN WILL LATITUDE/LONGITUDE: 3 3.618 3 01 / 117.9 344 2 5 PROJECT MANAGER: VISIT THE SITE AS REQUIRED FOR ROUTINE MAINTENANCE.THE PROJECT WILL NOT ZONING VENDOR: DRAWN BY: AL RESULT IN ANY SIGNIFICANT DISTURBANCE OR EFFECT ON DRAINAGE;NO SANITARY SEWER SERVICE,POTABLE WATER,OR TRASH DISPOSAL IS REQUIRED AND NO SITE ADDRESS: 3 714 [CS] LAKE AVENUE (S L C 0 9 0 2),� LEASING VENDOR: COMMERCIAL SERVICE, POTABLE IS NEW. CONSTRUCTION MANAGER: CHECKED BY: MM GENERAL NOTES NEWPORT BEACH , CA 92663 A/EMANAGER: PROPERTY OWNER: UTILITY MANAGER: 0 Dig Alert AREA MAPS APPROVALS KnowwharsbeloW. .,- o CalI before you dig. 00 41 \�' , • d B 09/21/2018 100%CONSTRUCTION CALIFORNIA SOUTH r •r Shwa AT&T PROPOSES TO INSTALL A NEW WIRELESS INSTALLATION LOCATED IN THE PUBLIC RIGHT Call Two Working Da Before You Di '+'h i PR y A 09/17/2018 90%CONSTRUCTION 9 Days 9! - - hf - .__ Iy OF WAY TO(N)CONCRETE LIGHT POLE. 811/800-227-2600 REV DATE DESCRIPTION i +•' `.�-' --___ THE SCOPE WILL CONSIST OF THE FOLLOWING: 1h _ AT&T TO REMOVE (1) EXISTING CONCRETE STREETLIGHT DIG ALERT AT&T TO INSTALL (1) 29'-3-CONCRETE STREETLIGHT .1 _- AT&T TO INSTALL (4) NEW AT&T REMOTE RADIO UNITS �pF r-, AT&T TO INSTALL (1) NEW AT&T OMNI-DIRECTIONAL ANTENNA S1 TL AT&T TO INSTALL (1) NEW AT EQUIPMENTSHROUD PUBLIC/PRIVATE: PUBLIC RIGHT-OF-WAY `�- $sne//�; AT&T TO INSTALL (i) NEW RAYCAP DISCONNECT ��.Jlp' �c (� 3714[CS]LAKE AVENUE(SLC0902), k r r ,/r•.l! AT&T TO INSTALL (1) NEW HANDHOLE ❑ m ! : ADDRESS: / F NEWPORT BEACH,CA 92663 ��n ? _ SI APPLICANT: AT&T - - -? Shopping 11 all W �a r ADDRESS: 1452 EDINGER AVE l 1-. •'•� 4v Ne*pq I TUSTIN,CA 92780 :�--� IslandPROJECT DESCRIPTION LATITUDE(NADD8 -117.933.6 301 ` •" \ G 9 S1 /a /do - `��' CIV��- � LONGITUDE(NAD 83): -117.934425 NG TYPE: NAD-83 � �°j'� � E GROUND GROUND ELEVATION(NAND 88) %%X' y. p, V SHEET NO: SHEET TITL JURISDICTION: CITY OF NEWPORT BEACH f CURRENT ZONING: PUBLIC RIGHT OF WAY k, #y T-1 TITLE SHEET K- � �+F�'� PROPOSED USE: UNMANNED TELECOMMUNICATIONS GN-1 GENERALNOTESl POWER COMPANY: SCE A-1 SITE PLAN IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY Sti �F AREACTING UNDER THE DIRECTION OF A LICENSED ADDRESS: POMONA,CA WAY "'� - " // �C'�r { �,` A-2 ELEVATIONS PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. POMONA,CA 91768 - 4 @ 1® A3 ELEVATIONS The OF3gl[1']I IVSBL.Ma 2nd 5! A-4 SITE IMAGE ' U 3�tnUan Kitchen D-1 DETAILS PROJECT SITE INFORMATION .,�� s a2 DETAILS SITE ID:CSTAM007 y' y S-1 POLE DETAILS 3714[CS]LAKE AVENUE(SLC0902) PROJECT MANAGER: ENGINEER. N ".s S Newport P S tllthe E-1 ELECTRICAL&GROUNDING DETAILS NEWPORT BEACH,CA 92663 M SQUARED WIRELESS M SQUARED WIRELESS a `�'' � l Isla-1;{ 1387 CALLE AVANZADO 1387 CALLE AVANZADO SAN CLEMENTE,CA 92673 SAN CLEMENTE,CA 92673 VICINITY MAP LOCATION MAP SAC/ZONING/PERMITTING: SENIOR TECHNICAL PROJECT MANAGER: M SQUARED WIRELESS AT&T SHEET TITLE 1387 CALLE AVANZADO 1452 EDINGER AVE. SAN CLEMENTE,CA 92673 TUSTIN,CA 92618 DIRECTIONS FROM AT&T OFFICE: 7. TURN RIGHT ONTO 38TH ST DRAWING INDEX RF ENGINEER: CONTACT:TED SUEKAWA DIRECTION ARE TAKEN FROM DESTINATION WILL BE ON THE LEFT. TITLE SHEET AT&T EMAIL:TS4994@ATT.COM 1452 EDINGER AVE. 3714[CS]LAKE AVENUE(SLC0902),NEWPORT BEACH CA 92663 1452 EDINGER AVE. TUSTIN,CA 92780 TUSTIN,CA 92618 1. TURN LEFT ONTO EDINGER AVE CONTACT:KARLO DAVINAGRACIA 2. TURN LEFT ONTO STATE ROUTE 55 S SUBCONTRACTOR SHALL VERIFY ALL PLANS&EXISTING DIMENSIONS&CONDITIONS ON EMAIL:KD270J@ATT.COM 3. MERGE ONTO STATE ROUTE 55 S THE JOB SITE&SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY SHEET NUMBER 4. CONTINUE ONTO NEWPORT BLVD DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. 5. TURN RIGHT ONTO 32ND ST PROJECT TEAM 6. TURN RIGHT ONTO W BALBOA BLVD DRIVING DIRECTIONS DO NOT SCALE DRAWINGS T-1 1.THE FACILITY IS AN UNOCCUPIED DIGITAL TELECOMMUNICATION FACILITY. Q NEW ANTENNA GROUT OR PLASTER T T TELCO RUN 5/8"X 10'-0",CU.GND ROD IN TEST WELL 30" 2.PLANS ARE NOT TO BE SCALED AND ARE INTENDED TO BE A DIAGRAMMATIC EXISTING ANTENNA O (E)BRICK MIN.BELOW GRADE. OUTLINE ONLY,UNLESS NOTED OTHERWISE.THE WORK SHALL INCLUDE FURNISHING T/E POWER/TELCO RUN MATERIALS,EQUIPMENT,APPURTENANCES AND LABOR NECESSARY TO COMPLETE ® GROUND ROD (E)MASONRY CHEMICAL GROUND ROD ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS.a I G G GROUNDING CONDUCTOR (XIT GROUND ROD) ���� �— GROUND BUS BAR CONCRETE 3.PR OR AND BE RESPONSIBLE FOR ALL CONTRACT DOCUMENTS,FIELD CONDITIONS OR TO THE SUBMISSION OF BIDS,THE CONTRACTORS SHALL VISIT THE JOB SI �. CADWELD CONNECTION AND DIMENSIONS,AND CONFIRMING THAT THE WORK MAY BE ACCOMPLISHED AS �. • MECHANICAL GRND.CONN. EARTH GROUNDING CONDUCTOR SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION.ANY DISCREPANCIES ARE TO • BE BROUGHT TO THE ATTENTION OF THE IMPLEMENTATION ENGINEER AND GRAVEL MECHANICAL CONNECTION ENGINEER PRIOR TO PROCEEDING WITH THE WORK. ■ CADWELD CONDUIT UNDERGROUND 4.THE CONTRACTOR SHALL OBTAIN,IN WRITING,AUTHORIZATION TO PROCEED ❑ ® PLYWOOD , HALO GROUND CONNECTION BEFORE STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED OR IDENTIFIED BY l GROUND ACCESS WELL THE CONTRACT DOCUMENTS. SAND FUSE,SIZE AND TYPE AS INDICATED. - �L CIRCUIT BREAKER 5.THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN - ELECTRIC BOX WOOD CONT. ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY 0H SAFETY SWITCH,2P-240V-60A W/60A FUSES,NEMA 3R INDICATED OTHERWISE OR WHERE LOCAL CODES OR REGULATIONS TAKE ENCLOSURE,SO D CATALOG NO.H222NR6 PRECEDENCE. TELEPHONE BOX � WOOD BLOCKING QM UTILITY METER BASE E R I C5 SON }� TRANSFER SWITCH,2P-240V-200A,NO FUSE, 6.ALL WORK PERFORMED AND MATERIALS INSTALLED SHALL BE IN STRICT '( Y LIGHT POLE STEEL O1 MANUAL MANUAL ENCLOSURE O ACCORDANCE WITH ALL APPLICABLE CODES,REGULATIONS AND ORDINANCES. 33O COMMERCE,$TE.20U �"TTTIII--` TRANSFORMER CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, LIGHTING FIXTURE,FLUORESCENT,10.94"x 4'-0",2/40W, ORDINANCES,RULES,REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC I RV I N E,CA 92602 CENTERLINE AUTHORITY REGARDING THE PERFORMANCE OF THE WORK.MECHANICAL AND ® FIND.MONUMENT ® SURFACE MOUNTING TYPE,HUBBELL LIGHTING CATALOG ELECTRICAL SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE PROPERTY/LEASE LINE #WSW2327 STEPDOWN TRANSFORMER MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS,AND LOCAL AND STATE LIGHTING FIXTURE,FLUORESCENT,10.94"x 8'-0",2/95W, JURISDICTIONAL CODES,ORDINANCES AND APPLICABLE REGULATIONS. SPOT ELEVATION MATCH LINE SURFACE MOUNTING TYPE,HUBBELL LIGHTING CATALOG #TWSM232T RECEPTACLE,2P-3W-125V-15A,DUPLEX, 7.THE GENERAL CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK,USING THE GROUND TYPE,HUBBEL CATALOG#5362 BEST SKILLS AND ATTENTION.THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE LIGHTING FIXTURE,HIGH PRESSURE SODIUM,1/70W,WALL SET POINT FOR ALL CONSTRUCTION MEANS,METHODS,TECHNIQUES,SEQUENCES AND WORK POINT MOUNTING TYPE,OR 1/50W HUBBELLULB LIGHTINGBELL IGHTIN CATAOGA#NRG72TALOG NRG-307 TOGGLE SWITCH,iP-125V-15A, PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE ■; 1Q REVISION GROUND CONDUCTOR S HUBBELL CATALOG#HBL 1201CN CONTRACT INCLUDING CONTACT AND COORDINATION WITH THE IMPLEMENTATION M S QU A R `J -- - - -- -- EXIT SIGN,THERMOPLASTIC LED,SINGLE FACE,UNIVERSAL W I R E L E ENGINEER AND WITH THE LANDLORD'S AUTHORIZED REPRESENTATIVE. SS MOUNTING,WBATTERY PACK,HUBBELL LIGHTING CATALOG c #PRB J TOGGLE SWITCH,1P-120V-15A,"WP" 8.SEAL PENETRATIONS THROUGH FIRE RATED AREAS WITH U.L.LISTED AND FIRE 1 3 8 7 C A L L E A V A N Z A D O XO GRID REFERENCE A COAXIAL CABLE WP COMBINATION,EXIT SIGN 8 EMERGENCY LIGHTING, CODE APPROVED MATERIALS. SAN CLEMENTE CA 92673(949)391-6824 ou OVERHEAD SERVICE EXIT HUBBELL LIGHTING CATALOG#PRC IONIZATION SMOKE DETECTOR W/ALARM 9.PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN X DETAIL REFERENCE CONDUCTORS SO HORN&ON CONTACT,120 VAC, 2-A OR 2-A10BC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF THE X CHAIN LINK FENCING EMERGENCY LIGHTING,2/50W,HUBBELL LIGHTING CATALOG GENTEX PART NO.710OF PROJECT AREA DURING CONSTRUCTION. #HE6-50-2-R91 O POLE 10.DETAILS ARE INTENDED TO SHOW END RESULT OF DESIGN.MINOR MODIFICATIONS X ELEVATION REFERENCE —01R/01-01i/°HP— OVERHEAD TELEPHONE/OVERHEAD POWER � CATALOG LIGHTING FIXTURE,INCANDESCENT, ,WALL MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS,AND SUCH MOUNTING TYPE,HUBBELL LIGHTING CATALOG MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK. #BRH-100-06-1 - (N)POLE MOUNTED XFMER DRAWN BY: AL —°�. °�.— OVERHEAD TELEPHONE LINE 11.REPRESENTATIONS OF TRUE NORTH,OTHER THAN THOSE FOUND ON THE PLOT OF YA X SURVEY DRAWING(SHEET LS7 OR SHEET C-1),SHALL NOT BE USED TO SECTION REFERENCE LIGHTING FIXTURE,HALOGEN,QUARTZ,1/300W,HUBBELL OVERHEAD POWER LINE LIGHTING CATALOG#QL-505 0 (E)POLE MOUNTED XFMR IDENTIFY OR ESTABLISH THE BEARING OF TRUE NORTH AT THE SITE.THE CHECKED BY: MM CONTRACTOR SHALL RELY SOLELY ON THE PLOT OF SURVEY DRAWING AND ANY SURVEYOR'S MARKINGS AT THE SITE FOR THE ESTABLISHMENT OF TRUE NORTH, E POWER RUN (N)PAD MOUNTED XFMER AND SHALL NOTIFY THE ENGINEER PRIOR TO PROCEEDING WITH THE WORK IF l Y'( LIGHTING FIXTURE,1/175W.METAL HALIDE,HUBBELL CAT ANY DISCREPANCY IS FOUND BETWEEN THE VARIOUS ELEMENTS OF THE WORKING F/P FIBER/POWER RUN �( #MIC-0175H-336 DRAWINGS AND THE TRUE NORTH ORIENTATION AS DEPICTED ON THE CIVIL �Q (E)PAD MOUNTED XFMER SURVEY.THE CONTRACTOR SHALL ASSUME SOLE LIABILITY FOR ANY FAILURE TO 0 5/8"X 10'-0",CU.GND ROD 30"MIN.BELOW GRADE. NOTIFY THE ENGINEER. 12.THE CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING ABBREVIATIONS IMPROVE MENTS,PAVING,CURBS,VEGETATION,GALVANIZED SURFACES,ETC.,AND UPON COMPLETION OF WORK REPAIR ANY DAMAGE THAT OCCURRED DURING CONSTRUCTION TO THE SATISFACTION OF AT&T. A AMPERE EMT. ELECTRICAL METALLIC TUBING MTD MOUNTED T.O.F. TOP OF FOUNDATION 13.KEEP GENERAL AREA CLEAN HAZARD FREE,AND DISPOSE OF ALL DIRT,DEBRIS, A.B. ANCHOR BOLT E.N. EDGE NAIL MTE MOUNTING T.O.P. TOP OF PLATE(PARAPET) RUBBISH AND REMOVE EQUIPMENT NOT SPECIFIED AS REMAINING ON THE B 09/21/2018 100%CONSTRUCTION ABV. ABOVE ENCL. ENCLOSURE MTL, METAL T.O.S. TOP OF STEEL PROPERTY.LEAVE PREMISES IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, AC ALTERNATE CURRENT/AIR CONDITIONER ENG. ENGINEER MTS. MANUAL TRANSFER SWITCH T.O.W. TOP OF WALL DUST OR SMUDGES OF ANY NATURE. A 09/17/2018 90%CONSTRUCTION ACCA ANTENNA CABLE COVER ASSEMBLY EQ. EQUAL N NEUTRAL TYR TYPICAL REV DATE DESCRIPTION ADD'L ADDITIONAL EXST.(E) EXISTING (N) NEW U.G. UNDERGROUND 14.PENETRATIONS OF ROOF MEMBRANES SHALL BE PATCHED/FLASHED AND MADE A.F.F. ABOVE FINISHED FLOOR EXP. EXPANSION NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOC. U.L. UNDERWRITERS LABORATORY INC. WATERTIGHT USING LIKE MATERIALS IN ACCORDANCE WITH NRCA ROOFING A.F.G. ABOVE FINISHED GRADE EXT. EXTERIOR NO.(#) NUMBER UMTS UNIVERSAL MOBIL TECH.SYS.(3G MOBILE TECH.) STANDARDS AND DETAILS.CONTRACTOR SHALL OBTAIN DETAILING CLARIFICATION AIC AMPERE INTERRUPTING CAPACITY FAB. FABRICATION(OR) N.T.S. NOT TO SCALE U.N.O. UNLESS NOTED OTHERWISE FOR SITE-SPECIFIC CONDITIONS FROM ENGINEER,IF NECESSARY,BEFORE ALUM. ALUMINUM FAC. FACTOR OBIF OPTICAL BASEBAND INTERFACE V VOLT PROCEEDING. ALT. ALTERNATE F/A FIRE ALARM OH OVERHEAD VAC VOLT ALTERNATING CURRENT ANT. ANTENNA F.F. FINISH FLOOR O.C. ON CENTER V.I.F. VERIFY INFIELD �pF E55rfl� APPROX. APPROXIMATE(LY) F.G. FINISH GRADE OPNG. OPENING W WATT OR WIRE 15.BEFORE ORDERING AND/OR BEFORE FABRICATING/CONSTRUCTING/INSTALLING ANY ARCH. ARCHITECT(URAL) FIN. FINISHED) P POLE WD WIDE(WIDTH) ITEMS,VERIFY THE TYPES AND QUANTITIES. �(/f� .t �W�•Q'fT AT. AMPERETRIP FLR. FLOOR P/C PRECAST CONCRETE W/ WITH V' AWG. AMERICAN WIRE GAUGE FLUOR FLUORESCENT PCs PERSONAL COMMUNICATION SERVICES W/O WITHOUT ({I D'�A a C, BATT. BATTERY FDN. FOUNDATION PH PHASE WD. WOOD 16.CONTRACTOR SHALL PROVIDE SITE FOREMAN WITH A CELLULAR PHONE AND /� BD. BOARD F.O.C. FACE OF CONCRETE PLY. PLYWOOD W.P. WEATHERPROOF PAGER,AND KEEP SAME ON SITE WHENEVER PERSONNEL ARE ON SITE. �7 BLDG. BUILDING F.O.M. FACE OF MASONRY PNLBD PANELBOARD WT. WEIGHT �� 7 BILK. BLOCK F.O.S. FACE OF STUD PPC POWER PROTECTION CABINET XFER TRANSFER 17.THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS ON THE SITE UJ ! BLKG. BLOCKING F.O.W. FACE OF WALL PRC PRIMARY RADIO CABINET XFMR TRANSFORMER AND NOTIFY THE PROJECT MANAGER OF ANY DISCREPANCIES BEFORE STARTING LC BM. BEAM F.S. FINISH SURFACE PRI PRIMARY XLPE CROSS-LINK POLYETHYLENE ANY WORK. B.N. BOUNDARY NAILING FT.(') FOOT(FEET) P.S.F. POUNDS PER SQUARE FOOT C CENTERLINE BR. BRANCH FTG. FOOTING P.S.I. POUNDS PER SQUARE INCH 18.CONTRACTOR TO PROVIDE COMPLETE SET OF AS BUILT DRAWINGS WITHIN 10 BTRCW. BARE TR. INNED COPPER WIRE GU GROUND PWR. POWER(CABINET)T. URE ED WORKING DAYS OF PROJECT COMPLETION. C[v'L ¢�\ BTS. BASE TRANSMISSION SYSTEM GR GROWTH(CABINET) QTY. QUANTITYCAS- B.O.F. BOTTOM OF FOOTING GA. GAUGE RAD.(R) RADIUS 1. AN APPROVED ENCROACHMENT PERMIT IS REQUIRED FOR ALL WORK 19.CONTRACTOR IS TO EXCAVATE 6"BELOW EXISTING GRADE AND SPRAY WITH WEED `T B/U BACK-UP CABINET GIN. GENERATOR RBS RADIO BASE STATION ACTIVITIES WITHIN THE PUBLIC RIGHT-OF WAY. CONTROL.REPLACE WITH CLASS II AGGREGATE BASE AND CRUSHED WASHED C CONDUIT GI. GALVANIZE(D) (BASE STATION 3G NETWORKS) 2 CONTRACTOR SHALL PROVIDE LANE CLOSURE PLANS PER WATCH ROCK.AS SPECIFIED ON SITE PLAN. CAB. CABINET G.F.C.I. GROUND FAULT CIRCUIT INTERRUPTER RCPT. RECEPTACLE CANT. CANTILEVER(ED) GLB.(GLU-LAM) GLUE LAMINATED BEAM REF. REFERENCE HANDBOOK AND STAKE OF CALIFORNIA DEPARTMENT OF 20.CONTRACTOR SHALL PROVIDE TOILET FACILITY DURING ALL PHASES OF CB. CIRCUIT BREAKER GND GROUND REINF. REINFORCEMENT(ING) TRANSPORTATION STANDARDS. CONSTRUCTION. IT ISAVIouTION OF uw FOR ANY PERSON,UNLESS THEY CDMA CODE-DIVISION MULTIPLE ACCESS(2G&3G) GPS GLOBAL POSITIONING SYSTEM REQ'D. REQUIRED 3. CONTRACTOR TO RETURN E STREET LIGHT AND LIGHT ARM TO THE CITY ARE ACTING UNDER THE DIRECTION OF A LICENSED CDUK CONSOLIDATION DISTRIBUTION UNIT KIT GRND. GROUND RGS. RIGID GALVANIZED STEEL 21.PRIOR TO THE COMMENCEMENT OF CONSTRUCTION OR THE FABRICATION OF PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. C.I.P. CAST IN PLACE GSM GLOBAL SYSTEM MOBILE(2G+MOBILE TECH.) RRU REMOTE RADIO UNIT OF NEWPORT BEACH UTILITIES YARD.IF DAMAGED DURING THE REMOVAL, MATERIALS TO BE INSTALLED AT THE SITE,THE CONTRACTOR SHALL FIELD VERIFY CKT. CIRCUIT HDBC HARD DRAWN COPPER WIRE (RADIO TRANSCEIVER) CONTRACTOR SHALL BE REQUIRED TO PURCHASE AND DELIVER A ALL DIMENSIONS INCLUDING AS-BUILT DIMENSIONS OF EXISTING STRUCTURES OR C CLEAR HGR, HANGER SAF SAFETY CLG. CEILING HDR. HEADER RECEIVER AIR INTERFACE TRAY REPLACEMENT.CITY OF NEWPORT BEACH UTILITIES YARD:949 W.16TH STRUCTURAL ELEMENTS HAVING A BEARING ON THE SCOPE OF THE WORK TO BE AF CMU CONCRETE MASONRY UNIT(JAMB BLOCKS) HPS HIGH PRESSURE SODIUM $CH. SCHEDULE STREET NEWPORT BEACH CA 92663.CONTRACTOR SHALL DISPOSE OF THE PERFORMED.IF ANY DISCREPANCY IS FOUND BETWEEN THE VARIOUS ELEMENTS COL. COLUMN HT. HEIGHT SDBC SOFT DRAWN BARE COPPER OF THE WORKING DRAWINGS AND THE DIMENSIONS OR CONDITIONS FOUND TO BE CONC. CONCRETE ICGB. ISOLATED COPPER GROUND BUS SEC SECONDARY EXISTING STREET LIGHT POLE AND ARMS IF UNWANTED BY THE CITY OF EXISTING IN THE FIELD,THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND SITE ID:CSTAM 007 CONN. CONNECTION(OR) IN.(") INCH(ES) SHT. SHEET ANY REASON. OBTAIN DESIGN RESOLUTION PRIOR TO PROCEEDING WITH THE PORTION(S)OF THE CONST. CONSTRUCTION INT. INTERIOR SIM. SIMILAR 4. WHERE REMOVED OR DAMAGED BY CONSTRUCTION,ALL CURB,GUTTER WORK AFFECTED.THE CONTRACTOR SHALL ASSUME SOLE LIABILITY FOR ANY 3714[CS]LAKE AVENUE(SLC0902) CONT. CONTINUOUS LB.(#) POUND(S) S.N. SOLID NEUTRAL AND SIDEWALK SHALL BE REPLACED IN ENTIRE SECTIONS BETWEEN FAILURE TO SO NOTIFY THE ENGINEER AND OBTAIN RESOLUTION BEFORE NEWPORT BEACH,CA 92663 d PENNY(NAILS) L.B. LAG BOLTS SPEC. SPECIFICATION(S) DBL. DOUBLE L.F. LINEAR FEET(FOOT) SQ. SQUARE EXPANSION JOINTS.NO SAW CUTTING AND PARTIAL PATCHING SHALL BE PROCEEDING. Dc DIRECT CURRENT LG. LENGTH S.S. STAINLESS STEEL PERMITTED.ALL CONSTRUCTION DETAILS FOR REPLACEMENT SECTIONS DEM. DEMAND L. LONG(ITUDINAL) STD. STANDARD SHALL BE PER CITY OF NEWPORT BEACH. DEFT. DEPARTMENT LPS LOW PRESSURE SODIUM STL. STEEL 5. THE CONTRACTOR SHALL REPAIR,REPLACE OR RE-ROUTE ALL D.F. DOUGLAS FIR LTE LONG TERM EVOLUTION(4G MOBILE TECH.) STRUC. STRUCTURAL DIA. DIAMETER MAS. MASONRY SURF SURFACE LANDSCAPE.IRRIGATION LINES AND FIXTURES IN KIND INCLUDING LINE DIAG. DIAGONAL MAX. MAXIMUM SW SWITCH SIZE,HEAD TYPE,SPACING AND CONTROL WHERE DAMAGED BY SHEET TITLE DIM. DIMENSION M.B. MACHINE BOLT TEL. TELEPHONE DWG. DRAWING(S) MECH. MECHANICAL TEMP. TEMPORARY CONSTRUCTION TO THE SATISFACTION OF THE CITY OF NEWPORT BEACH. DWL. DOWEL(S) MFR. MANUFACTURER THK. THICK(NESS) 6. THE CONTRACTOR SHALL REPLACE ALL EXISTING GROUNDCOVER, GENERAL NOTES EA. EACH MIN. MINIMUM TMAS TOWER MOUNTED AMPLIFIER INCLUDING SAND AND ALL OTHER LANDSCAPING INCLUDING TURF, EGR. EMERGENCY GENERATOR RECEPTACLE MISC. MISCELLANEOUS (DC SUPPLY VOLTAGE) EL. ELEVATION MLO MAIN LUGS ONLY T.N. TOE NAIL SHRUBS,AND/OR TREES IN KIND INCLUDING SIZE,SPECIES AND SPACING ELEC. ELECTRICAL T.O.A. TOP OF ANTENNA ELEV. ELEVATORHERE DAMAGED BY NEW CONSTRUCTION TO THE SATISFACTION OF THE TOCOP OF CURB T.O.C.. CITY OF NEWPORT BEACH. 7. ANY LANE CLOSURES SHALL STRICTLY ABIDE THE CALIFORNIA MUTCD FOR SHEET NUMBER TRAFFIC CONTROL. GN-1 ABBREVIATIONS 121 CITY OF NEWPORT BEACH NOTES 131 GENERAL NOTES 14 NOTE: 1. IF DIMENSIONS SHOWN ON PLAN DO NOT SCALE CORRECTLY,CHECK FOR REDUCTION OR ENLARGEMENT FROM ORIGINAL PLANS. f 2. UTILITY DESIGN&RUNS ARE PRELIMINARY.PENDING FINAL DESIGN FROM UTILITY CONTRACTORS TO VERIFY SUB STRUCTURE LOCATIONS PRIOR TO ANY EXCAVATION. at&t PROVIDERS. 3. /4. ALL CONDUCTORS WIRES 8 CONDUIT,SHALL BE INSTALLED IN A NEAT&TIDY FASHION. ALL EXCESS WIRE SLACK IS TO BE REMOVED&HIDDEN AS MUCH AS POSSIBLE. 5. ALL NEWLY INSTALLED EQUIPMENT SHALL BE PAINTED TO MATCH EXISTING POLE,8 I OR SURROUNDINGS UNLESS PROHIBITED PER MANUFACTURER. 6. NEW FIBER CONDUIT TO BE STUBBED OUT OF NEW POLE FOOTING BY APPROX.2'-Y. 7. POWER SUPPLY AND RUN ARE SUBJECT TO CHANGE PER SCE FINAL DESIGN. 1 CANAL BEACH ERICSSON I I (E)CITY OF NEWPORT BEACH CONCRETE 330 COMMERCE,STE.200 CANAL STREETLIGHT(0902)TOBE REMOVED B IRVINE,CA92602 BUILDING (E)SIDEWALK(TYP.) i REPLACED W/(N)CITY OF NEWPORT BEACH I (Typ) , CONCRETE STREETLIGHT W/(E)EQUIPMENT AT SAME LOCATION(BY AT&T) (N)U/G FIBER RUN FROM(N)FIBER I HANDHOLE TO(N)CONCRETE I w I STREETLIGHT(BY AT&T),SEE NOTE 6 Q I (N)FIBER HANDHOLE TO BE PLACED BELOW GRADE(BY OTHERS)w M S QU A R r ' (N)U/G POWER RUN FROM(N)WiR HANDHOLE INEW AT&T PROJECT LOCATION. 2 TO(N)CONCRETE STREETLIGHT(8V AT&T) WIRELESS SEE ENLARGED SITE PLAN I 1387 CALLE AVANZADO \ yP (N) HA TO BE PLACED 6.8.9 SAN CLEMENTE CA 92873(949)391-8824 BELOWOW GRADEDE HANDHOLE AT&T) D-1 (E)STREETLIGHT HANDHOLE (E)SIDEWALK(TYP.) \\�/ A 2 tiP e O SIGN E I \ I J ----- ----^ DRAWN BY AL rn ROW.—_____ C/F I , , CHECKED BY: MM 38TH ST C/F ROW._—_____—_____ B 09/21/2018 100%CONSTRUCTION m A 09/17/2018 90%CONSTRUCTION REV DATE DESCRIPTION I � I 5'-0"TOE -- f—__—__—__—__ OF LAKE AVE C/F I 38TH STVV I m 4 -�- I �pFE55rfl� m C/F I cc)yP °z I I � o I I c 5a � c[vi I I w Iw Iu QI J I Q IT BUILDING , ■ , IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ■ , I J ARE ACTING UNDER THE DIRECTION OF A LICENSED (TYPO i • m PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. I , m w I I Q I I SITE ID:CSTAM 007 Lu Y I i (E)TREE(TYR) 3714[CSI LAKE AVENUE(SLC0902) `\ I PROPOSED t85'U/G POWER RUN; NEWPORT BEACH,CA 92663 J I TRENCHED OR BORED FROM(E) CANAL` UTILITY POLE TO(N)WTR HANDHOLE, i I I rn SEE NOTE 7(BY AT&T) I m (E)U/G TRANSFORMER, _ PROPOSED POWER P.O.C., SHEET TITLE I 6'-6" , IT-6- 13'-6" I 6'-6" \� SEE NOTE7 SITE PLAN I I l i 1 LL i ' e' 0 0 8 �' 0 ®Y' a SHEET NUMBER Elk A 1 SITE PLAN 24"x36" SCALE: '" = '- " 20' - 1 ENLARGED SITE PLAN 24"x36" SCALE: 1/8" = 1'-U" 4' 8' 16' A 11"x17" SCALE: 1" = 40 40'-0" 11"x17" SCALE: 1/16"= 1'-°" 2 NOTE: 1.ALL NEW EQUIPMENT SHALL BE PAINTED TO MATCH NEW; E LIGHT POLE _ at&t 2.RE-USE E LED LUMINAIRE.IF NOT LED,REPLACE WITH(N)LED LUMINAIUMINAI RE APPROVED BY THE CITY. ERICSSON 330 COMMERCE,STE.200 IRVINE,CA 92602 L OF(N)ANTENNA 3Il A.G.L. - (N)ANTENNA MOUNTED ON(N) 1� }�C/L OF(N)ANTENNA EQUIPMENTSHROUD D-1 29'-0'A.G.L. e/OF N ANTENNA (N)EQUIPMENT SHROUD W/(2)(N)AT&T 28'-0"A.G.L. - 2203 RADIO,(1)(N)2205 RADIOS(1) 2-5 `;FUTURE 2205 RADIO&(1)(N)RAYCAP D-1 M SQUAR EQUIPMENT SHROUD DISCONNECT SWITCH WITHIN SHROUD J T/ WIRELESS 2 -0OF .L. 1387 CALLE AVANZADO V N LUMINAIRE SAN CLEMENTE CA 92673(949)391-6824 25'-0"A.G.L. A.G 24 N EQUIPMENT SHROUD 24 .L. }�T24 /OF(E)LUMINAIRE T/OF N POLE A. 2 CONTACT SIGN RE-USE(E)LED LUMINAIRE, SEE NOTE 2 DRAWN BY: AL T/OF E POLE 21'-0"A.G.L. CHECKED BY: MM r(N)ANTENNA SIGN D-2 (E)RELOCATED STREET SIGNS (E)STREET SIGNS TO BE B 09/21/2018 100%CONSTRUCTION RELOCATED TO(N)POLE A 09/17/2018 90%CONSTRUCTION TIP (E)SIGN I T/OF(E)SIGN REV DATE DESCRIPTION 12'-6"A.G.L. LAKE AVE 12'-0'A.G.L. ZAVE SEE SHEET S-1 FOR POLE DIAMETERS co cc) Wx� cl lL+ �4 7 DC (E)STREET SIGNS TO BE (E)RELOCATED STREET SIGNS RELOCATED TO(N)POLE 7. (E)CITY OF NEWPORT BEACH CONCRETE T/OF(E)SIGN STREETLIGHT BEACH (BY AT&T)RTE S-1 �qf C10- D¢��STREETLIGHT(0902)TO BE REMOVED&REPLACED s•-o"A.G.L. (BY AT&T) �OF CA4�F 6,8,9(N)WTR HANDHOLE (E)HANDHOLE D-1 (BEYOND)(BY AT&T) (E)SCE POLE FOUNDATION 6 (N)POLE FOUNDATION(BY AT&T) 1 IT ISAVIOLATION OF LAW FOR ANY PERSON,UNLESS THEY (N)FIBER BOX(BY D-2 ARE ACTING UNDER THE DIRECTION OF A LICENSED D-1 OTHERS) PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. OD LEVEL EGD LEVEL SITE ID:CSTAM 007 3714[CS)LAKE AVENUE(SLC0902) NEWPORT BEACH,CA 92663 _r _ (N)U/G FIBER RUN FROM(N)FIBER HANDHOLE TO(N)CONCRETE STREETLIGHT(BY AT&T);SEE NOTE 6 SHEET TITLE (N)U/G POWER RUN FROM(N) ELEVATIONS WTR HANDHOLE TO(N)CONCRETE STREETLIGHT(BY AT&T) SHEET NUMBER EXISTING SOUTHWEST ELEVATION 111"x17" SCALE: 3/116"-='1'a0" °® 2 NEW SOUTHWEST ELEVATION 24"x36" SCALE: 3/17" SCALE: 3/1 _ ''-°" 2' A-2 11"x6" = 1'-0" NOTE: 1.ALL NEW EQUIPMENT SHALL BE PAINTED TO MATCH NEW CONCRETE LIGHT POLE - 2.RE-USE LED LUMINAIRE.IF NOT LED,REPLACE at&t WITH(N)LEDED LUMINAIRE APPROVED BY THE CITY. ERICSSON 330 COMMERCE,STE.200 IRVINE,CA 92602 }�T/OF(N)ANTENNA 30'-0"A.G.L. (N)ANTENNA MOUNTED ON(N) �1 �C/L OF(N)ANTENNA EQU PMENTSHROUD D-1 29'-0"A.G.L. B/OF N ANTENNA (N)EQUIPMENT SHROUD W/(2)(N)AT&T 28'-0"A.G.L. 2203 RADIO,(1)(N)2205 RADIOS(1) 2-5-0"(N)EQUIPMENT SHROUD FUTURE 2205 RADIO&(1)(N)RAYCAP D-1 M SQU A R ��J T/ DISCONNECT SWITCH WITHIN SHROUD WIRELESS 28O A.G.L. 1387 CALLE AVANZADO T/OF N LUMINAIRE SAN CLEMENTE CA 92673(949)391-6824 25'-0"A.G.L. 24'-6"A.G OF N EQUIPMENT SHROUD .L. TI OF E LUMINAIRE T/OF N POLE 23'-0"A.G.L. 24•-6"A.G.L. 2 EMERGENCY CONTACT RE-USE(E)LED LUMINAIRE, SEE NOTE 2 DRAWN BY: AL It OF E POLE 21'-0"A.G.L. CHECKED BY: MM (N)ANTENNA SIGN D-2 (E)RELOCATED STREET SIGNS B 09/21/2018 100%CONSTRUCTION Vg E SIGN T/OF E SIGN A 09/17/2018 90%CONSTRUCTION 13'-6"A.G.L. 38TH STREET 13'-6"A.G.L. 38TH STREET SEE SHEET S-1 FOR POLE REV DATE DESCRIPTION DIAMETERS `. Q�pFE55r��A(E)RELOCATED STREET SIGNS e� 0 ��c, co r� w 54 7 (E)CITY OF NEWPORT BEACH T/OF(E)SIGN STREETLIGHT BEAC(CONCRETE S-1 �jqf C,'+v"• D¢��CONCRETE STREETLIGHT(0902)TO BE s•-o'•A.G.L. �OF CA4�F REMOVED&REPLACED(BY AT&T) 6,8,9 (N)WTR HANDHOLE 0.1 (BY AT&T) (N)POLE FOUNDATION(BY AT&T) 1 (E)POLE FOUNDATION 6 D-2 IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY (N)FIBER BOX(BY :� ARE ACTING UNDER THE DIRECTION OF A LICENSED D-1 OTHERS)(BEYOND) PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. (E)HANDHOLE OD LEVEL EGD LEVEL . SITE ID:CSTAM 007 3714[CS)LAKE AVENUE(SLC0902) NEWPORT BEACH,CA 92663 r (N)U/G FIBER RUN FROM(N)FIBER e HANDHOLE TO(N)CONCRETE STREETLIGHT(BY AT&T);SEE NOTE 6 SHEET TITLE RUN FROM WTR H)DIGANDHOPOWELE TO(N)CONC)RETE ELEVATIONS STREETLIGHT(BY AT&T) SHEET NUMBER EXISTING SOUTHEAST ELEVATION 114"x17" SCALE: 3/116"-='1'OC" ® Z NEW SOUTHEAST ELEVATION 24"x36" SCALE: 3/ _ ''-°" Z A-3 11"x17" SCALE: 3/16" = 1'-O" at&t f ERICSSON 330 COMMERCE,STE.200 IRVINE,CA 92602 M SQUTAR(•j (E)STREETLIGHT TO BE REPLACED 1987 CALLE AVANZADO SAN CLEMENTE CA 92673(949)391-6824 - - DRAWN BY: AL CHECKED BY: MM - ■�rrB 09/21/2018 100%CONSTRUCTION A 09/17/2018 1 90%CONSTRUCTION REV I DATE DESCRIPTION coC10- 2 � ■' ��q��F p41FGR� IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY l -" = ARE ACTING UNDER THE DIRECTION OF A LICENSED 7r PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. T• t� - _ .. - _ ��«.�..__ ��:_ �_- _'�� -- � ^.--,_�s_z-cam-� SITE ID:CSTAM 007 3714[CS)LAKE AVENUE(SLC0902) NEWPORT BEACH,CA 92663 SHEET TITLE SITE IMAGE SHEET NUMBER A-4 PROPOSED SITE LOCATION LOOKING NORTHWEST 24 11""x7"xl7" SCALE: NTS 1 SCALE: NTS AVAILABLE FROM EXCEL SIGN AND DECAL: ERICSSON MICRO RADIO 2205 GALTRONICS G02410416621 PSEUDO OMNI CANISTER ANTENNA MECHANICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS http://www.weneedsigns.com/home.php?cal+l 135 AND CLICK ON AT&T DIMENSIONS(MMH): 7.8-4.8417.87',INCLUDING MOUNTING DIMENSIONS(HxD): 24.9x 101NCHES VOLUME AND WEIGHT: 4 LITRES AND<4 kg S.(8.PH:510-651-0445 BRACKET AND kg IC FROM COVER 821bs) (E43 x 255 mm) N01-DC-16 1"X6"NOTICE DECAL MOUNTING: WALL AND POLEMOUM ® NO.OWEIGHF ONNECTEXCL UNTINGBRACKE S: 10X4.-10DS kg) a��t "For 1 Foot Distance"VINYL DECAL WITH ADHEDSIVE BACKING INTERFACESPECIFICATONS: CONK CONNECTORS 10 X4.30DIN FEMALFEMALE ANTENNA PORTS: 2 x 2.5-10(F) CONNECTOR TYPE B 4 X 4.110 DIN FEMALE 7.87" 7.B7 41- $4^ I- 6 FREQUENCY BAND[MHzI: 4X4.-10 DIN CPRI: 2x2.515110 Gbps(EXCHANGEABLE SFP MODULES) 5 (X d.3-10 DIN FEMALE OPTICAL INDICATORS: 6 O 10 (3550-3]00)MHz NAL FIELD GROUND:M: 1 O (515 -50) FEMALE FIELD GROUND: 1 O . . (5150d950)MHz IL 0 MAXWINDSPEED: 150 mpb " ELECTRICAL SPECIFICATIONS: r POWER SUPPLY: 48 VCD OR 100-250 VAC RADOME MATERIAL: ASA POWEROUTPUT: 97WATTS MAX O O SHIPPING DIMS(UMD): 30'X19'%19'(]62x48.3xd63Hnm MA%HEAT DISSIPATION: 90 WATTS GROSS SHIPPING WEIGHT: 26 lbs(12kg) Ole NOTICE m O O MINIMUM AC FUSE RATING: -MP 8 D 9 CC� RF energy emitted by this device may exceed the FCC's general 7 PART NO G0241 0-08 8 21-11(GRAY) ; public exposure limits.Stay at least 1 foot awayfrom the device. FRONT BACK SIDE ® PART NO.GQ2410-06621-611(CHROM P p y PART NO.GQ2410-06621-B11(CHROME) ERICSSON Cali 800-638-2822 for help if you need access within f foot 7.87° BOTTOM 330 COMMERCE,STE.200 IRVINE,CA 92602 Place 3 NOTICE sticker at the bottom of the front of TOP the radome of each antenna. FRONT M SQUAREE& WIRELESS OMNI ANTENNA DISCLAIMER LABEL 114"x17" SCALE: NTS 7 ERICSSON - RADIO 2205 24"x17" SCALE: NTS 4 GALTRONICS OMNI ANTENNA 24"x36" SCALE: NTS 1397 CALLE AVANZADO 11"x17" SCALE: NTS 11"x17" SCALE: NTS SAN CLEMENTE CA 92873(949)391-6824 ELECTROMATE RAYCAP-RSCA P-1 ERICSSON-MICRO RADIO 2203 CS53& 20.0 HINGED 3R ENCLOSURE MECHANICALSPECIFICATIONS ELECTRICAL MECHANICAL DIMENSIONS(WxDxH): ].6]'x3.94'x].8T,INCLUDING MOUNTING DIMENSIONS: CONNECTION TERMINAL COMPRESSION LUG pB-#14 AWG(13-2MM2) BRACKET AND ESTHETIC FRONT COVER SURGEPROTECTIONDEVICE(SPD)TYPE TO UL STRIKESORS 30-A TERMINAL BLOCK p10- AWG(6-S14MM2) VOLUME AND WEIGHT: 4LITRES AND<4.5 kg I—fbs) A 12" NUMBER OF CIRCUITS PROTECTED:4 ENVIRONMENTAL INGRESS MOUNTING: WALLANDPOLEMOUNT SURGE PROTECTIVE DEVICE(SPD)TYPE PER UL 14494TH EDITION: PROTECTION gP)RATING: NEMA. B 12" TYPE2COMPONENTASSEMBLY OPERATIONTEMPERATURE: (°C)_B CTO aWC DRAWN BY: AL SURGE PROTECTION DEVICE(SPD)CLASS TO IEC 61 11:CLASS II INTERFACE SPECIFICATIONS: STORAGE TEMPERATURE: (°C)-]0°CTO a80°C C 5" NOMINAL OPERATING VOLTAGE I[INI:1.PER ILL ENCLOSURETYPE _ 7.87" 7.B7" 3.94" ANTENNA PORTS: 2x4.3-10(F) NOMINAL DISCHARGE CURRENT IIMXI PER 14494TH EDITION:20 KA I20 MS fi—RATEDr CPRI: 2x 2.550Gbps(E%CNANGEABLESFP MAXIMUM DISCHARGE CONTINUOUS ORENTINGV PER IE[UCUMCOV) ABf20 MS (OUTDENCLOSURE RDIMEN ION: (L YCARBO­ UL9W H&N-X 5A8•X 10.W' MODULES) CHECKED BY: MM MAXIMUM CONTINUOUS OPERATING VOLTAGEIU 1—V)150V [21]"128.256 MM1 OPTICAL INDICATORS: 6 VOLTAGE PROTECTION LEVEL[UP]PER IEC 81843-11:]OOV WEIGHT: 2.25 LBS[1.02KGI VOLTAGE PROTECTION RATING NPR):20 KA 8120 EXTERNAL ALARM: 2 SUPPRESS ION TECHNOLOGY:MOV FIELD GROUND: 1 PROTECTION MODES(DUAL MODE):LINE TO NEUTRAL,NEUTRAL TO GROUND ELECTRICAL SPECIFICATIONS: F---. POWER SUPPLV: 48 VCD OR 1—VAC n r POWER OUTPUT: 9]WATTS MPX X HEAT ISSIPATION 1 D.28" Q Q MMIINIIMUM AC FUSE RATING' 6AMP�S 8.59" FRONT BACK SIDE Q 7.87" B 09/21/2018 100%CONSTRUCTION A 09/17/2018 90%CONSTRUCTION � co - °J REV DATE DESCRIPTION o io o N ® NPT 1"GLAND CAN BE REPLACED BY TOP B C CONDUIT FITTING pF E55r 7,, FRON7 SIDE BOTTOM M40 GLANDS CAN BE REPLACED BY 1 �P� '��� 6.25" 1/4"NPT CONDUIT FITTINGS V° 'rT 1 r� SCE UN-METERED FUSED PANEL 114"x17" SCALE: NTS 8 RAYCAP DISCONNECT z4::x11 SCALE NTS 5 ERICSSON - RADIO 2203 24"x35" SCALE: NTS 54 7 11"x17" SCALE: TITS 2 COVER FEATURES: SQUARE-D COMMSCOPE SCC HINGED 3R ENCLOSURE •STANDARD LOAD RATING:20,800 LBS.WHEEL LOAD -]6D236966 MECHANICAL SPECIFICATIONS # D221NRB ON10"x20"PLATE DIMENSIONSIWxDXH): 41.3^.1012- C[V)L R� DIMENSIONS: •2 BOLT DOWN LOCATIONS 9��OF CA4�F� •STAINLESS STEEL BOX INSERTS WEIGHT: 68 MS.(MG) A 7.75" •POLYMER CONCRETE CONSTRUCTION MOUNTING: MOUNTS TO TOP OF POLE B 9.63" •NON-SKID SURFACE STANDARD LIFT PINS(2 PL) C 3.75" •20K TO BE EMBOSSED ON COVER ♦' ____ Z° O ITISAVIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED •APPROXIMATE WEIGHT-120 LBS. i -_ PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. BOLT DOWNS(2 PL) =_ _____= TOP COVER FEATURES: = 2"x8"NAMEPLATE - • POLYMER CONCRETE CONSTRUCTION RECESS(1 PL) SITE ID:CSTAM 007 • LIGHTWEIGHT NON-SKID I 3714[CS]LAKE AVENUE(SLC0902) • STACKABLE FOOT (STANDARD) • APPROX.WEIGHT 188 LBS. z,Z NEWPORT BEACH,CA 92663 a O /3 J SHEET TITLE 3/8"x3"HEX BOLT I 4 DETAILS (2 PL EA END) /y B \ 012" (2)ERICSSON 2203 2 MOUNTING-BOTH SIDES SHEET NUMBER FRONT BOTTOM L RAYCAP POSITION AC (OR APPROVED EQUAL) °d X �a LOADCENTER OVP(OPTIONAL) D 1 AT&T MOBILITY FUSED DISCONNECT 12 "x36" SCALE NTS14"x17" SCALE: NTS 9 HANDHOLE 24"x3B" SCALE: NTS 6 EQUIPMENT SHROUD 24"x35" SCALE: NTS 3 11"x17" SCALE: TITS 11"x17" SCALE: TITS NOTE NOTES (4) 1"0 X ANCHOR RODS WITH 90' HOOK & 4" PROJ. POLE PER PLAN NEW CONDUITS AND UNDERGROUND FACTURES IN THE ROADWAY SHALL BE INSTALLED ADJACENT 1. ANY SIDEWALK REMOVALS MUST BE REPLACED IN FULL PANELS, IN ADD??%, (MIN. 55 KSI) HANDHOLE a f tt OR CLOSEST AS POSSIBLE TO THE EXISTING EDGE Ot GUTTER OR CURB. IF WE PRWO5E0 ANY EA7STINC CITY WPR0WMENTS/FA0 IRES DAMAGED DURING 7HE t CONDUIT TRENCH IS IN A TRAFFIC LANE ADJACENT TO THE EXISTING EDGE OF GUTTER OF CM, CONSTRUCTTaV SHALL BE REPLACED/REPAIRED A T THE APPLICANTS EXPENSE" CONCRETE APRON PVC CONDUIT STUBBED UP COLD PLANING AND PAWMEINT RESUWACING HILL BE REWIRED FROM THE NEAREST LANE LINE ADJACENT TO HAND HOLE, OF THE PROPOSED TRENCH TO THE EXISTING EDGE OF GUTTER OR CURB IF THE TRENCH WORK 2. SIDEWALK SMALL BE RESTORED IRTHIN ONE KEK OF INSTALLAP NP OF FINISHED GRADE NUMBER AND SIZE AS REQUIRED IS IN A TRAFFIC LANE BETNEEN TRAFFIC LANES THE CONIRACTOR NILL BE REQUIRED TO COLD NO GAP - SEAL WITH PLANE AND RESURFACE THE ENTIRE TRAFFIC LANE. THE TRENCH OPENING SHALL BE A NON-SHRINK LEVELING GROUT r MINIMUM OF 2'FROM THE ENTIRE TRAFFIC LANE. IN ADDITION, IF THE TRENCH WGRX EXTENDS INTO ANY PORTION OF AN ADJACENT TRAFFIC LANE OR IS DAMAGED AS A RESULT OF THE CONTRACTOR'S NARK OR IS LESS THAN 5'FROM AN EXISTING UTILITY TRENCIPI, THE CONTRACTOR NU BE REQUIRED TO COLD PLANE AND RESURFACE THE ENWE IRAFFIC LANE. �� - COLD PLANE EA7STING PAOWIlT(2-MIN" DEPTH) o AND RESURFACE XW FLUSH WTH EX. STREET ERIC550N PA WWNT FOR ENTIRE LANE AND RESTRIPE TRAFTTC LANES/INARKINGS OF ENTIRE LANE W NjiI TRENCHING OCCURS AND ANY CIRCUIT CONDUCTORS & 330 COMMERCE,STE.200 OTHER LANE DAMAGED AND TRAFFIC LOOP(S) CONDUIT To NEXT POLE, TYP., IRVINE,CA 92602 DURING CONSTRUCTION REPLACE SMEµALK SEE NOTE 4 PER STD-180-1 FURL LANE WQ?H W #3 HORIZ. TIES AT 12" O.C. (PARKING LANE OR DRIVE) VARIABLE •MNV W07H TRENCH MIN 3,000 PSI TYPE 24 INRU A.C. SECTION ¢� EX. CURB& GUTTER II CONCRETE 2' Q 1'� � MIN M S UAR �� —.�.F-- WIRELESS W .IQIN FLUSH 1387 CALLE AVANZADO EX CURB 41� GUTTER 2 - #5 BARS VERT. (60 KSI) SAN CLEMENTECA92673(949)391-6824 OR CURB a� z EX PAVEMENT w I I :' PIPE BEDWONG AND — — DACKFIL PER STD.—I06—L. 'e OR AS DETERIIARED BY THE FIELD ENpNEER (4) 1"0 X 36" ANCHOR RODS W/ .�/ 1�'_' 90- HOOK (MIN 55 KSI) DRAWN BY: AL REPLACE IHTH I' { �� #3 HORIZ. TIES @ 12" O.C. 1-7/2 M+N. THICKER A.C. THAN o CHECKED BY: MM - 49 z EX. A.C. SECT?% POLE BASE PLATE LOCATION PIPE BEDDING AND {COMPACTION 959 MIN.] 12 - #5 BARS VERT. (60 KSI) @ACKFItL PER STD.-I06-L I-112"MIN OR AS C£TERYA O BY THE MIN 3,000 PSI TYPE II CONCRETE FTFJD E&MV ER VARIABLE z s EX CITY OF NEWPORT BEACH UTIL117E5 CONCRETE NOTES: 1. ALL CONCRETE MATERIALS AND WORKMANSHIP SHALL CONFORM TO CHAPTER 19 1 a osizvzola 100%CONSTRUCTION (E.L SEiAERIWATER) OF THE CBC AND TO ALL REQUIREMENTS OF THE CURRENT EDITION OF ACI 318, "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE". A os11/2o18 90%CONS1111C1rION 5 MIN, 2. MIX DESIGN REQUIREMENTS: REV DATE DESCRIPTION 2.A. CEMENT SHALL BE TYPE II 2.8. COMPRESSIVE STRENGTH = 3,000 PSI NOTE.• 5 TREE 7S/ALLEYS RECENTLY(LAST 5 YEARS)SLURRIED/1iESURFA CEDIWAL T SHALL 2.C. MAXIMUM WATER/CEMENT RATIO (W/CM) SHALL BE 0.50 REQUIRE EXTENSIVE PAIEMENT RESTORA7ILW TO BE DETERMANED BY THE FIELD ENGINEER 3. ALL REINFORCING STEEL SHALL BE SECURED IN POSITION AND INSPECTED BY THE REVISED 612002 BUILDING OFFICIAL PRIOR TO PLACING CONCRETE. OFESSIfl 4. FOR FIBER CONDUIT, STUB OUT FROM FOUNDATION AWAY FROM STREET SIDE FOR QF� N,q� FUTURE FIBER HANDHOLE INSTALLATION. 5. ALL INTERNAL COMPONENTS, ANCHOR BOLTS, REBAR, PLATES ARE TO BE EPDXY 0�4, CITY OF NEWPORT BEACH DRAWING STD-105-L-C CITY OF NEWPORT BEACH DRAWING STD-105-L-D COATED OR GALVANIZED ROADWAY TRENCH DETAIL 11 x36" SCALE: NTS 4 PARKWAY TRENCH DETAIL 11 x36" SCALE: NTS 3 NEW FOUNDATION 11 x36" SCALE: NTS ) 54 "x17" SCALE: NTS "x17" SCALE: NTS "x17" SCALE: NTS 5" OF CA4�F� C3M s^ IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED • AT&T TOWERS PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. . In case of Emergency Contact E-mail:atttowers@att.com Phone:(877)231-5447 Stay Back Please Reference Site ID SITE ID:CSTAM 007 Radio-frequency energy site ID cRAN_RLos_csAN_om 3714[CS]LAKE AVENUE(SLC0902) may exceed exposure limits. FCC ID 0 NEWPORT BEACH,CA 92663 If questions,contact facility owner. 0 0 OWNER / OPERATOR NOTE: ANTENNA SIGNAGE: SITE ID LABEL TO BE AFFIXED AT OR NEAR THE POINT OF SHEET TITLE ON WOOD POLES - SIGN ON ALUMINUM WITH SS SCREW TO THE POLE POWER CONNECTION WITH TZeS241 LABELING TAPE OR ON METAL POLES - ADHESIVE VINYL OR PLACARD STRAPPED WITH SS TIES EQUIVALENT BLACK ON WHITE LABELING TAPE OF AT LEAST DETAILS ON CONCRETE / COMPOSITE - PLACARD STRAPPED WITH SS TIES 18mm WIDTH WITH EXTRA-STRENGTH ADHESIVE. USE ANY SIGN PLACEMENT: COMPATIBLE P-TOUCH LABEL MAKER. TEXT SHOULD BE AFFIX TO THE STRUCTURE 3-4' BELOW THE COMMERCIAL RE ANTENNA(S) PRINTED IN ALL CAPS WITH A MINIMUM HEIGHT OF 1/2". SIZE APPROX. 8" x 5" SHEET NUMBER ANTENNA SIGNAGE EMERGENCY CONTACT SIGN D-2 NOT USED 24"x36" SCALE NTS 5 POLE MOUNTED SIGNS 24"x36" SCALE: NTS 11%17" SCALE: NTS 11"x17" SCALE: NTS L FOR REFERENCE ONLY at&t REV. DATE DESCRIPTION DRN. APPR. 0 A 01/19 CHANGED COATING TO AMERSHIELD K.B. iow 7'LEVEL CONFIG CODES "P"LEVEL CONFIG CODES E RI CSSON OPTION CLASS ENTRY INFO. OPTION CLASS ENTRY INFO. 330 COMMERCE,STE.200 COATING I MIX 81 IRVINE,CA 92602 ANTENNA 12' DIA. x se"LG.(BY OTHERS) HH COVER 45209 FINISH 3 DOOR SCRS STD BASEPLATE 62470E MISC. MOD MODFE NOTE /8 COLLAR 55832E OCT (MOOBM): BLOCK DOWN 5-7/8' OCTAGONAL O.D. POLE TOP TO LENGTHPOLE TOP CON,, MOD93 5 (ACROSS FLATS) WtTH W-O" f 1" (ACROSS ALUMINUM TOP M SQUA J )COLLAR CAST-IN M0027 LI 1-7/8"f 5/8" I.D. STRUCT MOD MODDCI NOTE #9 R RACEWAY (STANDARD MOD93 POLE TOP) WIRELESS (4) 1/2"-13UNC X 1-3/4 SPL POLE LG MODEM 1' f 1' (TYP.) ; LG. COUPLINGS WITH 12" LG. 1387 CALLE AVANZADO ANCHORS O 90' APART ON A CENTRECON BASE PLATE OCTAGONAL POLES SAN CLEMENTE CA 92673(949)391-6824 0 •) 24" f 1" (TYP.) s 3-11/16" CIA. BOLT CIRCLE POLE POLE OVERALL ULTIMATE POLE (187 DESIG- HEIGHT POLE BOLT BASE G. MOMENT WEIGHT 02-3/5" O.D. GALV STEAL NATION ABOVE LENGTH CIRCLE O.D. (ft.-Ibs.) (Ibs.) PIPE O 270' (MOD27): GRADE 1-1/2"TAPERED TO 1-1/4" �:• WIRE IDcrr o 27P CBOXO8.5SPL 24'-6" 24'-9" 12-1/2" 9-1/4" 32.500 1250 • DRAWN BY: AL ( )POLES REQUIRED,EACH WITH: (1)B'GALVANIZED STEEL CLAMP ON ARM ASSEMBLY(PIN:T.B.D.) (4)OPTIONAL 1"x 36"x 4"GR.55 ANCHOR BOLTS(PIN:42026E) CHECKED BY: MM NOTES: im 1. MIX(8131):LA BLACK&WHITE,EXPOSED AGGREGATE FINISH WITH AMERSHIELD ANTI-GRAFFITI COATING. 2. ASTM C450 TYPE III GRAY CEM ENT. 92 27q 3. Pc @ 28 DAYS=7,000 PSI,USING SPUN CYLINDER TEST. POLE WIRE EXIT TOP DETAIL 4. Pc @ 28 DAYS=5,000 PSI,USING ASTM C-31 CYLINDER TEST. LENGTH • 44?_g• � 5. POLES MANUFACTURED TO ASTM C-1089-13 SPECIFICATIONS. PdLE HANDHOLE h 6. PROTECTIVE COAT EXPOSED P.C.WIRES AT POLE ENDS. AMERON I.D. TAG 7. PRESTRESSED WITH(8)9 MM DIA A-421 PRESTRESSING TENDONS. HEIGHT ADMPOLE ORIENTATION 8. MODFE:POLE BOTTOM PREPARATION FOR FREEZING OR CORROSIVE COASTAL B 09/21/2018 100%CONSTRUCTION GRADE 1 2 CLEAR ENVIRONMENTS;SEE DOCUMENTATION. A 09117/2018 90%CONSTRUCTION 2C 6" COVER (nP) 9. MODDCI:CORROSION INHIBITOR ADMIXTURE MODIFICATION. REV DATE DESCRIPTION 10.THE POLE DEPICTED ON THIS DRAWING IS DESIGNED TO WITHSTAND THE LOADS IMPARTED BY(1)TOP MOUNTEDANTENNA(NOT TO EXCEED 6.1 SQ FT EPA,115 (8) 9mm PRESTRESSING LBS)&(1)SINGLE CLAMP ON ARM(NOT TO EXCEED 6'LENGTH,2.5 SQ.FT.EPA, SPUNCAST, STEEL'MIRES 35 POUNDS)WITH THEARM HOLDING A DOWNWARD FACING AREA OR PENDANT PRESTRESSED ASTM A421 LUMINAIRE(NOT TO EXCEED 2.5 SQ.FT.EPA,50 POUNDS);THE POLE DEPICTED CONCRETE POLE 1-3/4'WALL IS DESIGNED TO WITHSTAND THE LOADS IMPARTED BY THE LIMA,LUMINAIRE& HAND HOLE #12 GA. SPIRAL ANTENNA AS DESIGNED PER THE ASCE 7-10 USING A 110 MPH WIND ZONE AMERON I.D.TAG O 0' FRAME STEEL WIRE AT 3' PITCH (3-SECOND GUSTS),RISK CATEGORY 2,NON-BUILDING STRUCTURE,EXPOSURE J8 GA z 6" ASTM A1064 C,SITE CLASS D,WITH SURFACE ROUGHNESS CATEGORY C,WITH NO HILL NOR 2-1/4" x 8-5/8" HANDHOLE BARE COPPER ESCARPMENT CONSIDERED.SEISMIC IS PER ASCE 7-10,CALIFORNIA BUILDING WITH CAST ALUMINUM FRAME GROUNDWIRE #11 CA. LONGITUDINAL CODE USING A MAXIMUM Ss=1.549&S1=0.578.PLEASE CONTACT&ADVISE k FLUSH COVER o O' SPIRAL CAGE WIRE STEEL WIRE WELDED MANUFACTURER IF INTENDED LOADING EXCEEDS THESE VALUES. COVER TO BE ATTACHED PRIOR (AT FRAME LOCATION) TO SPIRAL WIRE AM TO SHIPMENT WITH STANDARD B GROUND WIRE ARE ASTM A1064 (STD) DOOR SCREWS TO BE CONNECTED k SECURED PRIOR TO (2 7 CASTING CONCRETE POLE SECTION GRADE LINE APPROVED BY DATE 3" **SPECIAL GRADE ANCHORS" IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY M SQUARED WIRELESS ARE ACTING ENGINEER, DIRECTION THIS (4) 1" % 36"%4" GALV. ANCHOR (4) 1-1/4" DIA X 1-3/4" LG. PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. BOLTS WITH HEX NUTS AND 12' SO, z 1" THK. BASE SLOTS EQUALLY SPACED O 90' WASHERS ASTM F1554 GR.55 PLATE,ASTM A36. APART ON A 12" TO 13" DIA (P/N: 42026E OR EQUIVALENT BY GALVANIZED STEEL BOLT CIRCLE HUNTINGTON BEACH, CA OTHERS). FOUNDATION DESIGN IS BY OTHERS. SPECIFIC FOUNDATION DESIGNS MAY REQUIRE ALTERNATIVE DESIGNS POLE WITH 6'ARM ASSEMBLY SITE ID:CSTAM 007 )ED BOLT REQUIREMENTS 6" f 1/2" I.D. RACEWAY THIS DOCUMENT CONTAINS I/iaRMA7IDN'YN%5I S PROPPoETARY TO NATIONAI OLWEIl VARCO.R SHALL NOT BE 3714[CS]LAKE AVENUE(SLC0902) REPRODUCED,USED OR DISCLOSED TO ANYONE WnHOUT THE PRIOR WRITTEN PERMISSION OF NATIONAL OILMELL VARCO2 NEWPORT BEACH,CA 92663 BASE PLATE DETAIL DRAWN: A.F. DATE: 12/12/2018 Ak ier �11 SCALE: DWG. NO. ((�� R/E�V COMPLIANCE TO ANY CODE MDT EXPLICITLY LISTED ON THIS DRAWING IS NOT GUARANTEED. N.T.S. 1 U 1 2—V 2 7 A S PLEASE CONTACT NATIONAL OfLWELL VARCO IF YOU HAVE SPECfFIC CODE REQUIREMENTS. HEETTITLE POLE DETAILS SHEET NUMBER S-1 NOTE: EXOTHERMIC WELD CONNECTIONS 0 NOTE: ALL GROUND CONDUCTORS TO BE #6 UTILITY DESIGN AND RUNS ARE PRELIMINARY. PENDING THHN/THWN GREEN STRANDED COPPER MECHANICAL TYPE CONNECTIONS 0 FINAL DESIGN FROM UTILITY PROVIDERS UNLESS OTHERWISE NOTED OR REQUIRED BY EQUIPMENT MANUFACTURER. GROUNDING BAR 0 e (1) NEW 2205 RADIO & ACaR NEW ANTENNA at&t • D-1 D-1 • AC SOURCE (1) FUTURE RADIO • EIITTHER B2DORRB66AARE SAME BAND, pi (2) NEW 2203 RADIO AWS/PCS/WCS 5GHz RRH-3: (LAA), 2T2R MECHANICAL • USE OF DOUBLE MOUNTING BRACKETS a a a a a a CPRI CASCADING RRH-1/RRH-2 CONNECTION, TYP. + + + 44 (1) NEW 2205 RADIO & / / D-1 (1) FUTURE RADIO - D1 (2) NEW 2203 RADIO - NEW #18 AWG ERICSSON THHN/THWN STRANDED 330 COMMERCE,STE.200 DOUBLE DOUBLE IRVINE,CA 92602 MOUNTING MOUNTING THWN GREEN-,, THHN BRACKET RRH-1 RRH-3 BRACKET NEW # / 2203 B2 OR B66A 2205 B46 STRANDED GROUND FROM OPR/QC OPR QC EQUIPMENT TO GROUND BUS PSU PSU . NEW GROUND D1 NEW RAYCAP DISCONNECT WITH M SQUAR(•J FIBER BUS BAR RRH-2 INTEGRATED SURGE PROTECTION t WIRELE S SB2 OR B66A OPR/QC NEW DISCONNECT O O 1387 CALLE AVANZADO WITH INTERGRATED P SAN CLEMENTE CA 92873(949)3918824 °-1 SURGE PROTECTION FIBER AC CABLE AC CABLE 9 NEW AT&T D-1 DISCONNECT Ac cABLE 9 NEW AT&T D-1 'DRAWN BY: AL DISCONNECT FIBER CHECKED BY: MM 8 NEW SCE D1 UN—METERED FUSED PANEL AC CUT-OFF SWITCH e NEW SCE FIBER NEW #6 THHN/THWN D-1 UN—METERED DEMARCATION GREEN COPPERINNDED FUSED PANEL BOX/SPLICER Ac souRCE COATED MAIN GROUND CONDUCTOR/RISER B 09/21/2018 100%CONSTRUCTION EXOTHERMIC WELD NEW 1" SCH-80 PVC CONDUIT; A 09/17/2018 90%CONSTRUCTION DARK FIBERS CONNECTION TO NEW #12 AWG THHN/THWN STRANDED REV DATE DESCRIPTION TO/FROM HUB GROUND ROD -_ NEW 120V POWER SERVICE NEW 5/8"0 x 8'-0" OFE55rfl COPPER—CLAD STEEL GROUND ROD I �4 JIpT EXISTING POWER SUPPLY + 0'. coDip 02 r� PICO PLUMBING DIAGRAM 11.17' SCALE: NTS 5 GROUNDING SCHEMATIC 11 x36.. SCALE: NTS 3 SINGLE LINE DIAGRAM 11%17 SALE: ITS 1 54 7 11"x17" SCALE: NTS 9��OF CA4�F� CIO- STRIKESORB 120V a PROTECTION I IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY DISCONNECT SWITCH ARE ACTING UNDER THE DIRECTION OF A LICENSED IfYF11L PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. Q - 5 m D-1 W SITE ID:CSTAM 007 p1 CONNECTION FOR POWER IN 3714[CS]LAKE AVENUE(SLC0902) 4I NEWPORT BEACH,CA 92663 1 JUMPER GROUND O CONNECTIONS DEAD-FRONT FOR LIVE 7 AMP CIRCUIT BREAKERS COMPONENTS I SHEET TITLE ELECTRICAL DETAILS CHASSIS GROUND CONNECTION SHEET NUMBER E-1 NOT USED 24"x36" SALE ITs 6 NOT USED 24"x36" SALE: ITS 4 BREAKER SCHEDULE 24"x36" SCALE: NTS 11'%17" SCALE: ITS 11"x17" SCALE: NTS 11%17" SCALE: NTS 2