HomeMy WebLinkAbout20191213_ZA Action LetterCommunity Development Department
CITY OF NEWPORT BEACH
100 Civic Center Drive
Newport Beach, California 92660
949 644-3200
newportbeachca.gov/communitydevelopment
VIA EMAIL
December 16, 2019
Dynamite Sign Group
3080 E 29th St
Long Beach CA 90806
Subject: Comprehensive Sign Program No. CS2019-008
3800 – 3810 East Coast Highway
3800 and 3810 East Coast Highway Sign Program (PA2019-130)
Dear Mr. LeMenager,
Please be advised that the subject application was approved by the Zoning
Administrator on December 13, 2019 and is effective on January 2, 2020. A copy
of the approved action letter with findings and conditions is attached. If you have any
questions, please do not hesitate to contact me directly.
For additional information on filing an appeal or should you have any questions,
please contact our office at 949-644-3200 or you may contact me directly at 949-644-
3312.
Sincerely,
BMZ/jp
cc:
Brad Kuish
<kuishb@gmail.com>
Neil McNaught
<neilm@tntelectricsign.com>
COMMUNITY DEVELOPMENT DEPARTMENT
PLANNING DIVISION
100 Civic Center Drive, P.O. Box 1768, Newport Beach, CA 92658-8915
949-644-3200
www.newportbeachca.gov
ZONING ADMINISTRATOR ACTION LETTER
Subject: 3800 and 3810 East Coast Highway Sign Program (PA2019-130)
Comprehensive Sign Program No. CS2019-008
Site Location 3800 and 3810 East Coast Highway
Applicant Dynamite Sign Group
Legal Description Lots 50 and 51 in Block B, Tract No. 673
On December 13, 2019, the Zoning Administrator approved Comprehensive Sign Program
No. CS2019-008. This approval is in accordance to the provisions of Newport Beach
Municipal Code (NBMC) Chapter 20.42 (Sign Standards).
LAND USE AND ZONING
General Plan Land Use Plan Category: CC (Corridor Commercial)
Zoning District: CC (Commercial Corridor)
SUMMARY
Pursuant to NBMC Section 20.42.120 (Comprehensive Sign Program), a comprehensive
sign program is required whenever three or more separate tenant spaces are proposed for
a single site and when signage is proposed at or above the second story of a multi-story
building. Comprehensive sign programs provide a means for the flexible application of sign
regulations for projects that require multiple signs in order to provide incentives and latitude
in the design and display of multiple signs to achieve, not circumvent, the purpose of the
sign standards of the Zoning Code. The maximum sign area, total number, location, and
height of signs may be modified to the extent that the comprehensive sign program will
enhance the overall development consistent with the purpose of the Chapter 20.42 of the
Zoning Code. The increase the height and area of signs are limited to 20 percent and 30
percent respectively and a comprehensive sign program cannot authorize signs prohibited
by the Zoning Code.
The Comprehensive Sign Program will allow the following deviations from the Zoning Code:
a) The installation of both a tenant identification wall sign and a tenant
identification window sign, whereas the Zoning Code allows for only one
building sign, per tenant, per frontage;
b) The installation of wall signs above the second-story windows;
3800 and 3810 East Coast Highway Sign Program (PA2019-130)
December 13, 2019
Page 2
Tmplt: 07-25-19
c) The installation of wall signs outside the middle 50 percent of building or tenant
frontage; and
d) Tenant identification signs located on adjacent walls of the same building
separated by a distance of less than 30 feet, whereas the Zoning Code requires
a minimum separation of 30 feet measured along the exterior walls of the
building.
This approval is based on the following findings and standards and subject to the following
conditions:
FINDINGS AND STANDARDS FOR APPROVED SIGNS
Finding
A. The project is exempt from environmental review under the requirements of the
California Environmental Quality Act pursuant to Section 15311, Class 11 (Accessory
Structures).
Fact in Support of Finding:
1. Class 11 exempts minor structures accessory to existing commercial facilities,
including signs. The project site is an existing, multi-story, multi-tenant commercial
building. The proposed signs are incidental and accessory to the principal
commercial use of the property. The signs do not intensify or alter the use of the site.
Standard
B. The proposed sign program shall comply with the purpose and intent of this Chapter
[Chapter 20.42], any adopted sign design guidelines, and the overall purpose and
intent of this Section [Section 20.42.120 – Comprehensive Sign Program].
Facts in Support of Standard
1. The proposed Comprehensive Sign Program complies with the purpose and intent of
Chapter 20.42 (Sign Standards) because it provides the building tenants with adequate
identification while guarding against the excessive and confusing proliferation of signs.
2. The proposed Comprehensive Sign Program preserves and enhances the community
appearance by regulating the type, size, location, quantity, and illumination of signs.
A condition of approval limiting illumination has been included in this sign program.
Additionally, a condition of approval requiring subsequent approval of a building permit
prior to the installation of any signs has been included to ensure signs are installed per
the approved plans.
3800 and 3810 East Coast Highway Sign Program (PA2019-130)
December 13, 2019
Page 3
Tmplt: 07-25-19
3. The wall signs are designed to effectively identify building tenants using legible text
that contrasts with the background it is placed upon. This is consistent with the
adopted Citywide Sign Design Guidelines.
4. The size and location of signs have been selected to provide adequate identification
to passing motorists on East Coast Highway, Poppy Avenue, and Hazel Drive
without dominating the façades on which they are located.
Standard
C. The proposed signs shall enhance the overall development, be in harmony with, and
relate visually to other signs included in the Comprehensive Sign Program, to the
structures and/or developments they identify, and to surrounding development when
applicable.
Facts in Support of Standard
1. The site is developed with two, multi-story, multi-tenant, commercial buildings with
similar design and architecture. All building signs relate visually to each other and
the building’s design because they maintain consistency in design, materials, and
color while identifying the different tenant names.
2. The surrounding development along East Coast Highway is primarily commercial
uses within multi-tenant buildings. The surrounding signage is eclectic and includes
the use of wall, roof, pylon, window, awning and monument signs. The
Comprehensive Sign Program does not appear out of place and is harmonious with
surrounding development and signage.
3. The adjacent use to the rear of the project site is residential, however, no signage is
proposed along the rear façade of the property.
Standard
D. The sign program shall address all signs, including permanent, temporary, and
exempt signs.
Fact in Support of Standard
1. The Comprehensive Sign Program addresses all project signage. Temporary and
exempt signs not specifically addressed in the Comprehensive Sign Program shall
be regulated by the provisions of NBMC Chapter 20.42.
Standard
E. The sign program shall accommodate future revisions that may be required because
of changes in use or tenants.
3800 and 3810 East Coast Highway Sign Program (PA2019-130)
December 13, 2019
Page 4
Tmplt: 07-25-19
Facts in Support of Standard
1. The Comprehensive Sign Program has been developed to be effective for all allowed
commercial uses and includes flexibility for future changes in uses or tenants.
Adequate tenant identification has been provided through the increase in the number
of tenant identification sign locations.
2. It is not anticipated that future revisions to the Comprehensive Sign Program will be
necessary to accommodate changes in tenants. However, the Community
Development Director may approve minor revisions to the Comprehensive Sign
Program if the intent of the original approval is not affected.
Standard
F. The program shall comply with the standards of this Chapter [Chapter 20.42], ex cept
that deviations are allowed with regard to sign area, total number, location, and/or
height of signs to the extent that the Comprehensive Sign Program will enhance the
overall development and will more fully accomplish the purposes and intent of this
Chapter [Chapter 20.42].
Facts in Support of Standard
1. The Comprehensive Sign Program allows for increase in the number of signs. The
total number of signs per tenant is reasonable in order to preserve existing tenant
identification while integrating all new signage. The approval conforms to all other
standards of NBMC Chapter 20.42.
2. Allowing the wall signs not to be located in the middle 50 percent of a frontage
complements the architecture of the building, promotes a visually appealing pattern
for sign placement, and increases the visibility of signage to users traveling along
East Coast Highway. Additionally, this deviation allows for flexibility in the event that
the existing tenant configuration is modified in a way that creates additional suites
or combines suites.
3. Allowing the signs located on adjacent walls of the same building to be separated
by less than 30 feet is appropriate in this case given the length of the secondary
frontages of the project site and the architectural design of the buildings. The wall
signs along Hazel Drive shall be installed directly above a tenant entrance, near East
Coast Highway, and the wall-mounted directory sign facing Poppy Avenue is
installed at the corner of Poppy Avenue and East Coast Highway. The signs will be
visible to both pedestrian users and motorists on East Coast Highway. These users
would not be able to see the signage if it maintained the 30-foot separation required
by NBMC Chapter 20.42..
3800 and 3810 East Coast Highway Sign Program (PA2019-130)
December 13, 2019
Page 5
Tmplt: 07-25-19
4. Allowing the installation of wall signs above the second-story windows is appropriate
given the multi-story design of the building with different tenants occupying the
various floors.
Standard
G. The approval of a Comprehensive Sign Program shall not authorize the use of signs
prohibited by this Chapter [Chapter 20.42].
Facts in Support of Standard
1. The Comprehensive Sign Program acknowledges the existence of a nonconforming
roof sign, which is subject to abatement in compliance with NBMC Section 20.42.140
(Nonconforming Signs). A condition of approval has been added requiring the roof
sign to be removed in compliance with the Zoning Code.
2. The subject comprehensive sign program does not authorize any prohibited signs.
Standard
H. Review and approval of a Comprehensive Sign Program shall not consider the signs’
proposed message content.
Fact in Support of Standard
1. The Comprehensive Sign Program contains no regulations affecting sign message
content.
CONDITIONS OF APPROVAL
1. The development shall be in substantial conformance with the approved site plan,
details, elevations, and sign matrix except as noted in the following conditions.
2. Upon demolition of the existing structure or substantial change to the exterior of the
development on which this approval is based, this Comprehensive Sign Program
shall require subsequent review by the Planning Division and may render this
Comprehensive Sign Program null and void. A new Comprehensive Sign Program
in accordance with NBMC Chapter 20.42 would be required for the new or altered
development.
3. All signs shall be maintained in accordance with NBMC Section 20.42.170
(Maintenance Requirements). Temporary and exempt signs not specifically
addressed in the program shall be regulated by the provisions of NBMC Chapter
20.42.
4. Locations of the signs are limited to the designated areas and shall comply with the
limitations specified in the Sign Program Matrix (Attachment No. ZA 2) and any
3800 and 3810 East Coast Highway Sign Program (PA2019-130)
December 13, 2019
Page 6
Tmplt: 07-25-19
applicable sight distance provisions of NBMC Chapter 20.42 or as required by the
Public Works Department (City Standard 110-L).
5. The existing nonconforming roof sign is subject to NBMC Section 20.42.140
(Nonconforming Signs) or any successor section. NBMC Section 20.42.140.A
requires the roof sign to be removed by October 27, 2019, unless the City amends
NBMC Sections 20.42.140.A to allow an extension of time or alternatively, City
amends Chapters 20.42 to allow roof signs.
6. Illuminated signs shall be regulated in accordance with the provisions of Section
20.42.070 of the Newport Beach Municipal Code. If, in the opinion of the Community
Development Director, existing illumination creates an unacceptable negative impact
on the surrounding land uses or sensitive habitat areas, the Director may order the
dimming of light sources or other remediation upon finding that the site is excessively
illuminated.
7. In accordance with NBMC Section 20.42.120(F), the Community Development
Director may approve minor revisions to the Comprehensive Sign Program if the
intent of the original approval is not affected. This may include deviations on the
tenant configurations, such as combining or dividing suites.
8. A building permit shall be obtained prior to commencement of the construction
and/or installation of the signs.
9. Prior to issuance of building permits, the applicant shall submit to the Planning
Department an additional copy of the approved architectural plans for inclusion in
the Planning file. The plans shall be identical to those approved by all City
departments for building permit issuance. The approved copy shall include
architectural sheets only and shall be reduced in size to 11 inches by 17 inches.
The plans shall accurately depict the elements approved by this approval and shall
highlight the approved elem ents such that they are readily discernible from other
elements of the plans.
10. A copy of this letter, including conditions of approval and sign matrix, shall be
incorporated into the City and field sets of plans prior to issuance of the building
permits.
11. To the fullest extent permitted by law, applicant shall indemnify, defend and hold
harmless City, its City Council, its boards and commissions, officials, officers,
employees, and agents from and against any and all claims, demands, obligations,
damages, actions, causes of action, suits, losses, judgments, fines, penalties,
liabilities, costs and expenses (including without limitation, attorney’s fees,
disbursements and court costs) of every kind and nature whatsoever which may arise
from or in any manner relate (directly or indirectly) to City’s approval of the 3800 and
3810 East Coast Highway Sign Program including, but not limited to
Comprehensive Sign Program No CS2019-008 (PA2019-130) and the
determination that the project is exempt under the requirements of the California
3800 and 3810 East Coast Highway Sign Program (PA2019-130)
December 13, 2019
Page 7
Tmplt: 07-25-19
Environmental Quality Act. This indemnification shall include, but not be limited to,
damages awarded against the City, if any, costs of suit, attorneys' fees, and other
expenses incurred in connection with such claim, action, causes of action, suit or
proceeding whether incurred by applicant, City, and/or the parties initiating or bringing
such proceeding. The applicant shall indemnify the City for all of City's costs,
attorneys' fees, and damages which City incurs in enforcing the indemnification
provisions set forth in this condition. The applicant shall pay to the City upon demand
any amount owed to the City pursuant to the indemnification requirements prescribed
in this condition.
APPEAL PERIOD: An appeal or call for review may be filed with the Director of Community
Development or City Clerk, as applicable, within fourteen (14) days following the date the
action or decision was rendered. For additional information on filing an appeal, contact the
Planning Division at 949-644-3200.
Prepared by:
Approved by:
BMZ/jp
Attachments: ZA 1 Vicinity Map
ZA 2 Comprehensive Sign Program Matrix
ZA 3 Project Plans
Attachment No. ZA 1
Vicinity Map
Tmplt: 07-25-19
VICINITY MAP
Comprehensive Sign Program No. CS2019-008
PA2019-130
3800 and 3810 East Coast Highway
Subject Property
Attachment No. ZA 2
Comprehensive Sign Program Matrix
3800 and 3810 East Coast Highway Sign Program (PA2019-130)
Attachment No. ZA 2
3800 and 3810 East Coast Highway Comprehensive Sign Program No. CS2019-008
(PA2019-130) Matrix
Name Sign Type Frontage
Dimensions
Other Specifications
Sign Types A
and B – Tenant
ID
Building Sign –
Suspended
Primary Maximum Number: 2
Maximum Sign Area: 27 sq. ft.
Maximum Sign Height: 1’-6”
Maximum Letter Height: 12”
Maximum Sign Width: 18’
- Allowed on the 3800 E Coast Highway building.
Sign Type C –
Tenant ID
Building Sign –
Canopy
Mounted
Primary Maximum Number: 4
Maximum Sign Area: 14 sq. ft.
Maximum Sign/Letter/Logo Height: 12”
Maximum Sign Width: 14’
- Allowed on both the 3800 and the 3810 E Coast
Highway buildings.
- One per tenant.
- Illumination not permitted.
Sign Type E –
Multi-Tenant
Directory Sign
Building Sign -
Wall
Secondary Maximum Number: 1
Maximum Sign Area: 63.33 sq. ft.
.
Maximum Sign Height: 7’-11”
Maximum Sign Width: 8’
- Allowed on the secondary frontage facing Poppy
Ave.
3800 and 3810 East Coast Highway Sign Program (PA2019-130)
Attachment No. ZA 2
Sign Type Z –
Tenant ID
Building Sign -
Wall
Secondary Maximum Number: 2
Maximum Sign Area: 14 sq. ft.
Maximum Sign Height: 12”
Maximum Letter Height: 12”
Maximum Sign Width: 14’
- Allowed on the secondary frontage facing Hazel
Drive.
- One per tenant.
Sign Type G –
Tenant ID
Building Sign –
Window
Primary Maximum Number: 6
Maximum Sign Area: Varies
Maximum Sign Height: Varies
Maximum Sign Width: Varies
- Allowed on both the 3800 and the 3810 E Coast
Highway buildings.
- Window signs shall not exceed 20% maximum
coverage of each window area.
- One per tenant.
Sign Type H –
Building Address
Building Sign -
Wall
Primary Maximum Number: 2
Maximum Sign Area: 20.3 sq. ft.
Maximum Letter Height: 1’-5”
Maximum Sign Width: 4’-5”
- Allowed on both the 3800 and the 3810 E Coast
Highway buildings.
Sign Type I –
Roof Tenant ID
Existing Roof
Sign
Existing Signs: 2
- Subject to abatement in accordance with NBMC
20.42.140 Nonconforming Signs. Signs must be
removed by 10/27/2019, see Condition 5
Notes/Requirements:
a) Sign locations shall be as depicted on approved plans.
b) Wall signs shall be constructed of individual channel letters and attached per mounting details depicted on approved plans.
c) Requirements for all signs per Newport Beach Municipal Code (NBMC) Chapter 20.42 (Sign Standards), except as provided in this sign matrix.
d) Sign Designs shall be consistent with Citywide Sign Design Guidelines Manual.
e) Pursuant to NBMC Section 20.42.120(F), the Community Development Director may approve minor revisions to this approval if the intent of the
original approval is not affected.
Attachment No. ZA 3
Project Plans
Job Name:
Address:
Original Date:
Design Number:
Revisions:
Designer:
Scale: As Noted
This is an original unpublished drawing
created by TNT Electric Sign Co. It is
submitted for your approval. It is not to be
s h o w n t o a n y o n e o u t s i d e o f y o u r
organization, nor is it to be reproduced,
copied or exhibited in any fashion. The
changing of colors, sizes, materials or
illumination method does not alter the
design. Ownership of this design is held by
TNT Electric Sign Co. Authorization to use
this design in any fashion must be obtained
in writing from TNT Electric Sign Co.
© TNT Electric Sign Co. 2019
Note: The colors depicted here are a
graphic representation. Actual colors may
vary. See color specifications.
Page: of 1
3080 E 29TH ST
LONG BEACH, CA 90806
562 595 7725
3080 E 29TH ST
LONG BEACH, CA 90806
562 595 7725
CA LIC. C45 994192CA LIC. C45 994192
Visit us at:
tntelectricsign.com
Visit us at:
tntelectricsign.com
12
06/19/19
3800 & 3810 E. PCH
Sign Program
3800 & 3810 PCH
Corona Del Mar, CA
92625
19-06-3939-R09
R1: sp 7/25/19 revise per attachment
R2: sp 8/26/19 revise per notes
R3: jd 8/30/19 revise per notes
R4: jd 8/30/19 change to channel letters
R5: jd 9/9/19 update install method,
remove sign D
R6: jd 9/10/19 change sign Z to wall
mount
R7: jd 9/10/19 remove sign Z2, add
sign C5
R8: jd 9/12/19 revise per comments
R9: jd 10/10/19 revise per comments
John Nauta
Sales Rep:
Neil McNaught
E-mail:
NeilM@tntelectricsign.com
3800 & 3810 E. PCH
3800 & 3810 PCH / Corona Del Mar, CA 92625
Vicinity Map
Scale: NTS1
Job Name:
Address:
Original Date:
Design Number:
Revisions:
Designer:
Scale: As Noted
This is an original unpublished drawing
created by TNT Electric Sign Co. It is
submitted for your approval. It is not to be
s h o w n t o a n y o n e o u t s i d e o f y o u r
organization, nor is it to be reproduced,
copied or exhibited in any fashion. The
changing of colors, sizes, materials or
illumination method does not alter the
design. Ownership of this design is held by
TNT Electric Sign Co. Authorization to use
this design in any fashion must be obtained
in writing from TNT Electric Sign Co.
© TNT Electric Sign Co. 2019
Note: The colors depicted here are a
graphic representation. Actual colors may
vary. See color specifications.
Page: of 2
3080 E 29TH ST
LONG BEACH, CA 90806
562 595 7725
3080 E 29TH ST
LONG BEACH, CA 90806
562 595 7725
CA LIC. C45 994192CA LIC. C45 994192
Visit us at:
tntelectricsign.com
Visit us at:
tntelectricsign.com
12
06/19/19
3800 & 3810 E. PCH
Sign Program
3800 & 3810 PCH
Corona Del Mar, CA
92625
19-06-3939-R09
R1: sp 7/25/19 revise per attachment
R2: sp 8/26/19 revise per notes
R3: jd 8/30/19 revise per notes
R4: jd 8/30/19 change to channel letters
R5: jd 9/9/19 update install method,
remove sign D
R6: jd 9/10/19 change sign Z to wall
mount
R7: jd 9/10/19 remove sign Z2, add
sign C5
R8: jd 9/12/19 revise per comments
R9: jd 10/10/19 revise per comments
John Nauta
Sales Rep:
Neil McNaught
E-mail:
NeilM@tntelectricsign.com
SIGN PROGRAM
COMPREHENSIVE SIGN MATRIX
Note:
Suspended Types routed out cabinets painted black with ½” thick acrylic push through at 2nd floor,
12” tall max copy.
All 1st floor to be 12” tall max channel letters on raceway.
3800 South 70sf
3800 West 63.33 sf
3810 South 70 sq.
3810 East 28 sq.
Note:
No sandwich Board, No A Frame Sign allowed.
Window signs not to exceed 5 sq ft. of any tenant facing PCH.
Allowed to span multiple windows as long as vinyl doesn’t exceed 5 sq. ft. each
ALLOWABLE SQ. FT. CALCS
COMPREHENSIVE SIGN MATRIX
3800
1.
2.
EAST COAST HWY
Primary
Secondary
40’-0” Store Frontage
40 x 1.5 = 60 sq. ft. + 30% by ZA = 78 sq. ft. allowable
½ of Primary
78 = x ½ = 39 sq. ft. max allowable
3810 EAST COAST HWY
• Zoning Administrator Can Approve Up To 30% Extra square footage
(NBMC 20.42.120) Subsection C
30% of 60 = 18
60 + 18 = 78 sq. ft.
½ of 78 = 39 sq. ft.
Primary Frontage:
Secondary Frontage:
1.
2.
Primary
Secondary
40’-0” Store Frontage
40 x 1.5 = 60 sq. ft. + 30% by ZA = 78 sq. ft. max allowable
½ of Primary
78 / ½ = 39 sq. ft. max allowable
Up to 78 sq. ft.
Up to 39 sq. ft.
3800
1. A
2. C1
3. C2
4. E1
5.
N or E
Existing
Proposed
Proposed
Existing
Proposed
Suspended Tenant
Canopy Mount Tenant
Canopy Mount Tenant
Directory Wall Mount
Window Signs
(3) tenants x 5 sq ft. max
per tenant
Sq. Ft.
27
14
14
63.33
15
Location
South
South
South
West
South
Primary or Secondary
Primary
Primary
Primary
Secondary
3810
1. B
2. C3
3. C4
4.
5.
6.
N or E
Proposed
Proposed
Proposed
Proposed
Proposed
Proposed
Suspended Tenant
Canopy Mount Tenant
Canopy Mount Tenant
Wall Mount Tenant
Wall Mount Tenant
Window Signs
(3) tenants x 5 sq ft. max
per tenant
Sq. Ft.
27
14
14
14
14
15
Location
South
South
South
East
East
South
Primary or Secondary
Primary
Primary
Primary
Secondary
Secondary
Job Name:
Address:
Original Date:
Design Number:
Revisions:
Designer:
Scale: As Noted
This is an original unpublished drawing
created by TNT Electric Sign Co. It is
submitted for your approval. It is not to be
s h o w n t o a n y o n e o u t s i d e o f y o u r
organization, nor is it to be reproduced,
copied or exhibited in any fashion. The
changing of colors, sizes, materials or
illumination method does not alter the
design. Ownership of this design is held by
TNT Electric Sign Co. Authorization to use
this design in any fashion must be obtained
in writing from TNT Electric Sign Co.
© TNT Electric Sign Co. 2019
Note: The colors depicted here are a
graphic representation. Actual colors may
vary. See color specifications.
Page: of 3
3080 E 29TH ST
LONG BEACH, CA 90806
562 595 7725
3080 E 29TH ST
LONG BEACH, CA 90806
562 595 7725
CA LIC. C45 994192CA LIC. C45 994192
Visit us at:
tntelectricsign.com
Visit us at:
tntelectricsign.com
12
06/19/19
3800 & 3810 E. PCH
Sign Program
3800 & 3810 PCH
Corona Del Mar, CA
92625
19-06-3939-R09
R1: sp 7/25/19 revise per attachment
R2: sp 8/26/19 revise per notes
R3: jd 8/30/19 revise per notes
R4: jd 8/30/19 change to channel letters
R5: jd 9/9/19 update install method,
remove sign D
R6: jd 9/10/19 change sign Z to wall
mount
R7: jd 9/10/19 remove sign Z2, add
sign C5
R8: jd 9/12/19 revise per comments
R9: jd 10/10/19 revise per comments
John Nauta
Sales Rep:
Neil McNaught
E-mail:
NeilM@tntelectricsign.com
Plot Plan
Scale: nts1
C1
Pacific Coast
H
w
y
Pacific Coast
H
w
y
Pacific Coast
H
w
yPoppy AvePoppy AvePoppy Ave40'-0"40'-0"40'-0"89'-0"89'-0"Secondary FrontageSecondary Frontage89'-0"Secondary Frontage40'-0"40'-0"40'-0"76'-0"76'-0"Secondary FrontageSecondary Frontage76'-0"Secondary Frontage111'-0"
C2 C3 C4AB
E Hazel DrHazel DrHazel Dr40'-0"40'-0"40'-0"40'-0"40'-0"40'-0"
111'-0"
Primary Frontage
380038003800 381038103810
Z1
Z2
COMM
E
R
CI
A
L
COMM
E
R
CI
A
L
COMM
E
R
CI
A
L
COMM
E
R
CI
A
L
COMM
E
R
CI
A
L
COMM
E
R
CI
A
L
RESIDENTIALRESIDENTIALRESIDENTIAL
Job Name:
Address:
Original Date:
Design Number:
Revisions:
Designer:
Scale: As Noted
This is an original unpublished drawing
created by TNT Electric Sign Co. It is
submitted for your approval. It is not to be
s h o w n t o a n y o n e o u t s i d e o f y o u r
organization, nor is it to be reproduced,
copied or exhibited in any fashion. The
changing of colors, sizes, materials or
illumination method does not alter the
design. Ownership of this design is held by
TNT Electric Sign Co. Authorization to use
this design in any fashion must be obtained
in writing from TNT Electric Sign Co.
© TNT Electric Sign Co. 2019
Note: The colors depicted here are a
graphic representation. Actual colors may
vary. See color specifications.
Page: of 4
3080 E 29TH ST
LONG BEACH, CA 90806
562 595 7725
3080 E 29TH ST
LONG BEACH, CA 90806
562 595 7725
CA LIC. C45 994192CA LIC. C45 994192
Visit us at:
tntelectricsign.com
Visit us at:
tntelectricsign.com
12
06/19/19
3800 & 3810 E. PCH
Sign Program
3800 & 3810 PCH
Corona Del Mar, CA
92625
19-06-3939-R09
R1: sp 7/25/19 revise per attachment
R2: sp 8/26/19 revise per notes
R3: jd 8/30/19 revise per notes
R4: jd 8/30/19 change to channel letters
R5: jd 9/9/19 update install method,
remove sign D
R6: jd 9/10/19 change sign Z to wall
mount
R7: jd 9/10/19 remove sign Z2, add
sign C5
R8: jd 9/12/19 revise per comments
R9: jd 10/10/19 revise per comments
John Nauta
Sales Rep:
Neil McNaught
E-mail:
NeilM@tntelectricsign.com
South Elevation - 3800 Building
Scale: ¼” = 1’-0”1
South Elevation - 3800 Building
Scale: 3/32” = 1’-0”2
Note:
Field verify all dims prior to fab
380018’-0”
41’-0” store frontage
1’-6”
Existing Signage:
1’-6” x 18’-0” = 27 sf
Existing Window Graphics:
1’-8” x 3’-0” = 5 sf
Existing Window Graphics:
1’-6” x 3’-4” = 5 sf
Existing Window Graphics:
8 ½” x 2’-10” = 2 sf
8 ½” x 4’-2 ½” = 3 sf
Sign Area:
Proposed Sign C2
Proposed Sign C1
Existing Window Graphics
Gisova
Existing Sign A “The Hydration room”
Hydration Room
Botanica Floral
14.00 sq. ft.
27.00 sq. ft.
5.00 sq. ft.
5.00 sq. ft.
5.00 sq. ft.
14.00 sq. ft.
15.00 sq. ft.
A Existing 1’-6” x 18’-0”
Suspended Sign,
existing 12” letters
C1 C2 12” max letter x 14’-0”12” max letter x 14’-0”
Job Name:
Address:
Original Date:
Design Number:
Revisions:
Designer:
Scale: As Noted
This is an original unpublished drawing
created by TNT Electric Sign Co. It is
submitted for your approval. It is not to be
s h o w n t o a n y o n e o u t s i d e o f y o u r
organization, nor is it to be reproduced,
copied or exhibited in any fashion. The
changing of colors, sizes, materials or
illumination method does not alter the
design. Ownership of this design is held by
TNT Electric Sign Co. Authorization to use
this design in any fashion must be obtained
in writing from TNT Electric Sign Co.
© TNT Electric Sign Co. 2019
Note: The colors depicted here are a
graphic representation. Actual colors may
vary. See color specifications.
Page: of 5
3080 E 29TH ST
LONG BEACH, CA 90806
562 595 7725
3080 E 29TH ST
LONG BEACH, CA 90806
562 595 7725
CA LIC. C45 994192CA LIC. C45 994192
Visit us at:
tntelectricsign.com
Visit us at:
tntelectricsign.com
12
06/19/19
3800 & 3810 E. PCH
Sign Program
3800 & 3810 PCH
Corona Del Mar, CA
92625
19-06-3939-R09
R1: sp 7/25/19 revise per attachment
R2: sp 8/26/19 revise per notes
R3: jd 8/30/19 revise per notes
R4: jd 8/30/19 change to channel letters
R5: jd 9/9/19 update install method,
remove sign D
R6: jd 9/10/19 change sign Z to wall
mount
R7: jd 9/10/19 remove sign Z2, add
sign C5
R8: jd 9/12/19 revise per comments
R9: jd 10/10/19 revise per comments
John Nauta
Sales Rep:
Neil McNaught
E-mail:
NeilM@tntelectricsign.com
South Elevation - 3810 Building
Scale: ¼” = 1’-0”1
South Elevation - 3810 Building
Scale: 3/32” = 1’-0”2
381040’-0” store frontage
Existing Window Graphics:
2’-0” x 2’-6” = 5 sf
Vacated and removed
C3
TENANT
B 1’-6” x 18’-0”
Suspended Sign,
12” max letter height
C4
Sign Area:
Proposed Sign B
(3) tenents x 5 sq. ft. each
Proposed Sign C3
Window signs allowed
Proposed Sign C4
15.00 sq. ft
27.00 sq. ft.
18.00 sq. ft.
18.00 sq. ft.
Note:
Field verify all dims prior to fab
12” max letter x 14’-0”12” max letter x 14’-0”
Job Name:
Address:
Original Date:
Design Number:
Revisions:
Designer:
Scale: As Noted
This is an original unpublished drawing
created by TNT Electric Sign Co. It is
submitted for your approval. It is not to be
s h o w n t o a n y o n e o u t s i d e o f y o u r
organization, nor is it to be reproduced,
copied or exhibited in any fashion. The
changing of colors, sizes, materials or
illumination method does not alter the
design. Ownership of this design is held by
TNT Electric Sign Co. Authorization to use
this design in any fashion must be obtained
in writing from TNT Electric Sign Co.
© TNT Electric Sign Co. 2019
Note: The colors depicted here are a
graphic representation. Actual colors may
vary. See color specifications.
Page: of 6
3080 E 29TH ST
LONG BEACH, CA 90806
562 595 7725
3080 E 29TH ST
LONG BEACH, CA 90806
562 595 7725
CA LIC. C45 994192CA LIC. C45 994192
Visit us at:
tntelectricsign.com
Visit us at:
tntelectricsign.com
12
06/19/19
3800 & 3810 E. PCH
Sign Program
3800 & 3810 PCH
Corona Del Mar, CA
92625
19-06-3939-R09
R1: sp 7/25/19 revise per attachment
R2: sp 8/26/19 revise per notes
R3: jd 8/30/19 revise per notes
R4: jd 8/30/19 change to channel letters
R5: jd 9/9/19 update install method,
remove sign D
R6: jd 9/10/19 change sign Z to wall
mount
R7: jd 9/10/19 remove sign Z2, add
sign C5
R8: jd 9/12/19 revise per comments
R9: jd 10/10/19 revise per comments
John Nauta
Sales Rep:
Neil McNaught
E-mail:
NeilM@tntelectricsign.com
East Elevation - 3810 Building
Scale: 3/16” = 1’-0”1
East Elevation - 3810 Building
Scale: nts2
Z1
Note:
Field verify all dims prior to fab
76’-0” Frontage 3810
79’-0” Frontage
Sign Area:
Proposed Sign Z2
Proposed Sign Z1
14.00 sq. ft.
14.00 sq. ft.
Z2
12” max letter x 14’-0”
12” max letter x 14’-0”
Job Name:
Address:
Original Date:
Design Number:
Revisions:
Designer:
Scale: As Noted
This is an original unpublished drawing
created by TNT Electric Sign Co. It is
submitted for your approval. It is not to be
s h o w n t o a n y o n e o u t s i d e o f y o u r
organization, nor is it to be reproduced,
copied or exhibited in any fashion. The
changing of colors, sizes, materials or
illumination method does not alter the
design. Ownership of this design is held by
TNT Electric Sign Co. Authorization to use
this design in any fashion must be obtained
in writing from TNT Electric Sign Co.
© TNT Electric Sign Co. 2019
Note: The colors depicted here are a
graphic representation. Actual colors may
vary. See color specifications.
Page: of 7
3080 E 29TH ST
LONG BEACH, CA 90806
562 595 7725
3080 E 29TH ST
LONG BEACH, CA 90806
562 595 7725
CA LIC. C45 994192CA LIC. C45 994192
Visit us at:
tntelectricsign.com
Visit us at:
tntelectricsign.com
12
06/19/19
3800 & 3810 E. PCH
Sign Program
3800 & 3810 PCH
Corona Del Mar, CA
92625
19-06-3939-R09
R1: sp 7/25/19 revise per attachment
R2: sp 8/26/19 revise per notes
R3: jd 8/30/19 revise per notes
R4: jd 8/30/19 change to channel letters
R5: jd 9/9/19 update install method,
remove sign D
R6: jd 9/10/19 change sign Z to wall
mount
R7: jd 9/10/19 remove sign Z2, add
sign C5
R8: jd 9/12/19 revise per comments
R9: jd 10/10/19 revise per comments
John Nauta
Sales Rep:
Neil McNaught
E-mail:
NeilM@tntelectricsign.com
West Elevation - 3800 Building
Scale: ¼” = 1’-0”1
West Elevation - 3800 Building
Scale: nts2
3’-10” Verify11'-0"SWEAT SAUNA
AURA PILATES
THE HYDRATION ROOM
GABRIEL’S TAILORING
PAZ INGREDIENTS
WELL
BOTANICA FLORAL
FACIAL LOUNGE
EExisting Cabinet
7’-11” x 8’-0”
380089’-0” Frontage
89’-0” Frontage
75 SF Max
Sign Area:
Existing Cabinet 63.33 sq. ft.
Job Name:
Address:
Original Date:
Design Number:
Revisions:
Designer:
Scale: As Noted
This is an original unpublished drawing
created by TNT Electric Sign Co. It is
submitted for your approval. It is not to be
s h o w n t o a n y o n e o u t s i d e o f y o u r
organization, nor is it to be reproduced,
copied or exhibited in any fashion. The
changing of colors, sizes, materials or
illumination method does not alter the
design. Ownership of this design is held by
TNT Electric Sign Co. Authorization to use
this design in any fashion must be obtained
in writing from TNT Electric Sign Co.
© TNT Electric Sign Co. 2019
Note: The colors depicted here are a
graphic representation. Actual colors may
vary. See color specifications.
Page: of 8
3080 E 29TH ST
LONG BEACH, CA 90806
562 595 7725
3080 E 29TH ST
LONG BEACH, CA 90806
562 595 7725
CA LIC. C45 994192CA LIC. C45 994192
Visit us at:
tntelectricsign.com
Visit us at:
tntelectricsign.com
12
06/19/19
3800 & 3810 E. PCH
Sign Program
3800 & 3810 PCH
Corona Del Mar, CA
92625
19-06-3939-R09
R1: sp 7/25/19 revise per attachment
R2: sp 8/26/19 revise per notes
R3: jd 8/30/19 revise per notes
R4: jd 8/30/19 change to channel letters
R5: jd 9/9/19 update install method,
remove sign D
R6: jd 9/10/19 change sign Z to wall
mount
R7: jd 9/10/19 remove sign Z2, add
sign C5
R8: jd 9/12/19 revise per comments
R9: jd 10/10/19 revise per comments
John Nauta
Sales Rep:
Neil McNaught
E-mail:
NeilM@tntelectricsign.com
Sign Elevation Layout Square Footage: 27
Qty: One (1) Required Scale: ½” = 1’-0”A
Face: Routed out aluminum painted black
Cabinet: Interior illuminated cabinet
Illumination: White LEDs / power supplies mounted internally
Copy: ½” thick push through white acrylic
Manufacture and install interior illuminated cabinet sign
Returns: 5” deep aluminum painted black, clean backs
Note: Field verify all dims and conditions prior to fab
THE HYDRATION ROOM1’-0”120-277VAC J-box
Typical Section detail
Scale: nts11’-6”Aluminum retainers
Routed out aluminum
Light Emitting Diods (LED)
Low voltage wire
from LED to LED
Aluminum backs
Secondary class 2
low voltage wires
(no conduit required)
Grounding wire / screw
120-277VAC
disconnect switch
Self contained power supply
Interior alum. sq. tube frame
Counter sunk screws
Push through acrylic
Power supply
120-277VAC
disconnect switch
Grounding wire
secured to
grounding screw
1 ½” Alum. sq. tube
bolted to cabinet
Primary power
5” x 4’ x 1/8” Alum.
welded
#10 wood screw @3” embedment
(Qty: 10)9 ½"Bottom of existing canopy
Wood studs
1’-4 ½”18’-0”2’-2”4'-0" on centers 4'-0" on centers 4'-0" on centers
Aluminum Plate Plan View
Scale: 1 ½” = 1’-0”21 ½"5"1 ½"
4’-0” on centers
13’-0” continuous plate (5” wide)
Alum. sq. tube Wood studs Alum. plate
Weep holes7/8"3"embedmentThis sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and / or other applicable local codes. This includes proper grounding and bonding of the sign. All wall penetrations to be sealed with UL Listed silicone sealant. In the utilization of GFI Transformers and in accordance with NEC and UL Listed guidelines, it is
required that primary circuits to each sign must have dedicated circuits with proper ground from main panel and must be bonded. Any equipment or lighting that is added / shared to the primary sign circuit will cause GFI transformers to trip off. Neutral to ground should not exceed 3 volts to prevent GFI from tripping.
• Control for All Signs. All Signs with permanently connected lighting shall meet the requirements of Section 133. • Automatic Time Switch Control. All signs with permanently connected lighting shall be controlled with an automatic time switch that complies with the applicable requirements of Section 1198. • Photocontrol or outdoor astronomical time switch control.
All outdoor signs shall be controlled with a photocontrol or outdoor astronomical time switch unless exempted from the exceptions. See Section 133(a)2. • Dimming. All outdoor signs shall be controlled with a dimmer that provides the ability to automatically reduce sign power by a minimum of 65 percent during nighttime exempted from the 5 possible exceptions. See
Section 133(a)3. • Demand Responsive Electronic Message center Control (EMC), newly connected lighting power load greater than 15kW shall have a control installed that is capable of reducing the lighting power by a minimum of 30% when receiving a demand response signal that is sent out by the local utility.
SIGN LIGHTING CONTROLS
Sign
Voltage:120V
EXISTING SIGNAGEEXISTING SIGNAGEEXISTING SIGNAGE
Existing canopy
Job Name:
Address:
Original Date:
Design Number:
Revisions:
Designer:
Scale: As Noted
This is an original unpublished drawing
created by TNT Electric Sign Co. It is
submitted for your approval. It is not to be
s h o w n t o a n y o n e o u t s i d e o f y o u r
organization, nor is it to be reproduced,
copied or exhibited in any fashion. The
changing of colors, sizes, materials or
illumination method does not alter the
design. Ownership of this design is held by
TNT Electric Sign Co. Authorization to use
this design in any fashion must be obtained
in writing from TNT Electric Sign Co.
© TNT Electric Sign Co. 2019
Note: The colors depicted here are a
graphic representation. Actual colors may
vary. See color specifications.
Page: of 9
3080 E 29TH ST
LONG BEACH, CA 90806
562 595 7725
3080 E 29TH ST
LONG BEACH, CA 90806
562 595 7725
CA LIC. C45 994192CA LIC. C45 994192
Visit us at:
tntelectricsign.com
Visit us at:
tntelectricsign.com
12
06/19/19
3800 & 3810 E. PCH
Sign Program
3800 & 3810 PCH
Corona Del Mar, CA
92625
19-06-3939-R09
R1: sp 7/25/19 revise per attachment
R2: sp 8/26/19 revise per notes
R3: jd 8/30/19 revise per notes
R4: jd 8/30/19 change to channel letters
R5: jd 9/9/19 update install method,
remove sign D
R6: jd 9/10/19 change sign Z to wall
mount
R7: jd 9/10/19 remove sign Z2, add
sign C5
R8: jd 9/12/19 revise per comments
R9: jd 10/10/19 revise per comments
John Nauta
Sales Rep:
Neil McNaught
E-mail:
NeilM@tntelectricsign.com
This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and / or other applicable local codes. This includes proper grounding and bonding of the sign. All wall penetrations to be sealed with UL Listed silicone sealant. In the utilization of GFI Transformers and in accordance with NEC and UL Listed guidelines, it is
required that primary circuits to each sign must have dedicated circuits with proper ground from main panel and must be bonded. Any equipment or lighting that is added / shared to the primary sign circuit will cause GFI transformers to trip off. Neutral to ground should not exceed 3 volts to prevent GFI from tripping.
• Control for All Signs. All Signs with permanently connected lighting shall meet the requirements of Section 133. • Automatic Time Switch Control. All signs with permanently connected lighting shall be controlled with an automatic time switch that complies with the applicable requirements of Section 1198. • Photocontrol or outdoor astronomical time switch control.
All outdoor signs shall be controlled with a photocontrol or outdoor astronomical time switch unless exempted from the exceptions. See Section 133(a)2. • Dimming. All outdoor signs shall be controlled with a dimmer that provides the ability to automatically reduce sign power by a minimum of 65 percent during nighttime exempted from the 5 possible exceptions. See
Section 133(a)3. • Demand Responsive Electronic Message center Control (EMC), newly connected lighting power load greater than 15kW shall have a control installed that is capable of reducing the lighting power by a minimum of 30% when receiving a demand response signal that is sent out by the local utility.
SIGN LIGHTING CONTROLS
Sign
Voltage:120V
Sign Elevation Layout Square Footage: 27
Qty: One (1) Required Scale: ½” = 1’-0”B
Note: Field verify all dims and conditions prior to fab
Illumination: White LEDs / power supplies mounted internally
Face: Routed out aluminum painted black
Manufacture and install interior illuminated cabinet sign
Cabinet: Interior illuminated cabinet
Returns: 5” deep aluminum painted black, clean backs
Copy: ½” thick push through white acrylic
TENANT1’-0”Max Height120-277VAC J-box
Typical Section detail
Scale: nts1
Existing canopy1’-6”Aluminum retainers
Routed out aluminum
Light Emitting Diods (LED)
Low voltage wire
from LED to LED
Aluminum backs
Secondary class 2
low voltage wires
(no conduit required)
Grounding wire / screw
120-277VAC
disconnect switch
Self contained power supply
Interior alum. sq. tube frame
Counter sunk screws
Push through acrylic
Power supply
120-277VAC
disconnect switch
Grounding wire
secured to
grounding screw
1 ½” Alum. sq. tube
bolted to cabinet
Primary power
5” x 4’ x 1/8” Alum.
welded
#10 wood screw @3” embedment
(Qty: 16)9 ½"Bottom of existing canopy
Wood studs
1’-4 ½”18’-0”2’-2”4'-0" on centers 4'-0" on centers 4'-0" on centers
Aluminum Plate Plan View
Scale: ½” = 1’-0”21’-4"4"
4’-0” on centers
Alum. sq. tube Wood studs Alum. plate
Weep holes3"embedment4’-0” on centers 4’-0” on centers
CL8"2’-0"Wood studs
CL CL 1’-4"(Verify)CLCLCL8”4”CLCL
Job Name:
Address:
Original Date:
Design Number:
Revisions:
Designer:
Scale: As Noted
This is an original unpublished drawing
created by TNT Electric Sign Co. It is
submitted for your approval. It is not to be
s h o w n t o a n y o n e o u t s i d e o f y o u r
organization, nor is it to be reproduced,
copied or exhibited in any fashion. The
changing of colors, sizes, materials or
illumination method does not alter the
design. Ownership of this design is held by
TNT Electric Sign Co. Authorization to use
this design in any fashion must be obtained
in writing from TNT Electric Sign Co.
© TNT Electric Sign Co. 2019
Note: The colors depicted here are a
graphic representation. Actual colors may
vary. See color specifications.
Page: of 10
3080 E 29TH ST
LONG BEACH, CA 90806
562 595 7725
3080 E 29TH ST
LONG BEACH, CA 90806
562 595 7725
CA LIC. C45 994192CA LIC. C45 994192
Visit us at:
tntelectricsign.com
Visit us at:
tntelectricsign.com
12
06/19/19
3800 & 3810 E. PCH
Sign Program
3800 & 3810 PCH
Corona Del Mar, CA
92625
19-06-3939-R09
R1: sp 7/25/19 revise per attachment
R2: sp 8/26/19 revise per notes
R3: jd 8/30/19 revise per notes
R4: jd 8/30/19 change to channel letters
R5: jd 9/9/19 update install method,
remove sign D
R6: jd 9/10/19 change sign Z to wall
mount
R7: jd 9/10/19 remove sign Z2, add
sign C5
R8: jd 9/12/19 revise per comments
R9: jd 10/10/19 revise per comments
John Nauta
Sales Rep:
Neil McNaught
E-mail:
NeilM@tntelectricsign.com
Sign Elevation Layout Square Footage: 14
Qty: Four (4) Required Scale: ½” = 1’-0”
C2
This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and / or other applicable local codes. This includes proper grounding and bonding of the sign. All wall penetrations to be sealed with UL Listed silicone sealant. In the utilization of GFI Transformers and in accordance with NEC and UL Listed guidelines, it is
required that primary circuits to each sign must have dedicated circuits with proper ground from main panel and must be bonded. Any equipment or lighting that is added / shared to the primary sign circuit will cause GFI transformers to trip off. Neutral to ground should not exceed 3 volts to prevent GFI from tripping.
• Control for All Signs. All Signs with permanently connected lighting shall meet the requirements of Section 133. • Automatic Time Switch Control. All signs with permanently connected lighting shall be controlled with an automatic time switch that complies with the applicable requirements of Section 1198. • Photocontrol or outdoor astronomical time switch control.
All outdoor signs shall be controlled with a photocontrol or outdoor astronomical time switch unless exempted from the exceptions. See Section 133(a)2. • Dimming. All outdoor signs shall be controlled with a dimmer that provides the ability to automatically reduce sign power by a minimum of 65 percent during nighttime exempted from the 5 possible exceptions. See
Section 133(a)3. • Demand Responsive Electronic Message center Control (EMC), newly connected lighting power load greater than 15kW shall have a control installed that is capable of reducing the lighting power by a minimum of 30% when receiving a demand response signal that is sent out by the local utility.
SIGN LIGHTING CONTROLS
Sign
Voltage:120V ALLELECTRICAL
COMPONENTS12”Max height14’-0”
(Max length)
C3
C1
Top of canopy
Typical Section detail
Scale: nts1
Trimcap with # 8 screws
Acrylic face
Light Emitting Diods (LED)
Low voltage wire
from LED to LED
Aluminum backs
Drilled hole and filled
with silicone to prevent
water penetration
¼” weep holes
Secondary class 2
low voltage wires
(no conduit required)
Grounding wire / screw
Alum. backs clinched
to letter returns
Grounding wire
secured to
grounding screw
120-277VAC J-box
Raceway attachment
to trellis
Canopy Structure
by others
120-277VAC
disconnect switch
Raceway
Flex conduit
Power Supply
Trimcaps: ¾” White
Raceway: 3” x 5” raceway painted Matthews black
Returns: 5” pre-coat black
Manufacture and install face lit channel letters
Faces: White acrylic
Illumination: White LEDs / remote power supplies
Note: Field verify all dims and conditions prior to fab 3”C4
1’-0” Max height
Job Name:
Address:
Original Date:
Design Number:
Revisions:
Designer:
Scale: As Noted
This is an original unpublished drawing
created by TNT Electric Sign Co. It is
submitted for your approval. It is not to be
s h o w n t o a n y o n e o u t s i d e o f y o u r
organization, nor is it to be reproduced,
copied or exhibited in any fashion. The
changing of colors, sizes, materials or
illumination method does not alter the
design. Ownership of this design is held by
TNT Electric Sign Co. Authorization to use
this design in any fashion must be obtained
in writing from TNT Electric Sign Co.
© TNT Electric Sign Co. 2019
Note: The colors depicted here are a
graphic representation. Actual colors may
vary. See color specifications.
Page: of 11
3080 E 29TH ST
LONG BEACH, CA 90806
562 595 7725
3080 E 29TH ST
LONG BEACH, CA 90806
562 595 7725
CA LIC. C45 994192CA LIC. C45 994192
Visit us at:
tntelectricsign.com
Visit us at:
tntelectricsign.com
12
06/19/19
3800 & 3810 E. PCH
Sign Program
3800 & 3810 PCH
Corona Del Mar, CA
92625
19-06-3939-R09
R1: sp 7/25/19 revise per attachment
R2: sp 8/26/19 revise per notes
R3: jd 8/30/19 revise per notes
R4: jd 8/30/19 change to channel letters
R5: jd 9/9/19 update install method,
remove sign D
R6: jd 9/10/19 change sign Z to wall
mount
R7: jd 9/10/19 remove sign Z2, add
sign C5
R8: jd 9/12/19 revise per comments
R9: jd 10/10/19 revise per comments
John Nauta
Sales Rep:
Neil McNaught
E-mail:
NeilM@tntelectricsign.com
Sign Elevation Layout Square Footage: 14
Qty: Two (2) Required Scale: ½” = 1’-0”
This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and / or other applicable local codes. This includes proper grounding and bonding of the sign. All wall penetrations to be sealed with UL Listed silicone sealant. In the utilization of GFI Transformers and in accordance with NEC and UL Listed guidelines, it is
required that primary circuits to each sign must have dedicated circuits with proper ground from main panel and must be bonded. Any equipment or lighting that is added / shared to the primary sign circuit will cause GFI transformers to trip off. Neutral to ground should not exceed 3 volts to prevent GFI from tripping.
• Control for All Signs. All Signs with permanently connected lighting shall meet the requirements of Section 133. • Automatic Time Switch Control. All signs with permanently connected lighting shall be controlled with an automatic time switch that complies with the applicable requirements of Section 1198. • Photocontrol or outdoor astronomical time switch control.
All outdoor signs shall be controlled with a photocontrol or outdoor astronomical time switch unless exempted from the exceptions. See Section 133(a)2. • Dimming. All outdoor signs shall be controlled with a dimmer that provides the ability to automatically reduce sign power by a minimum of 65 percent during nighttime exempted from the 5 possible exceptions. See
Section 133(a)3. • Demand Responsive Electronic Message center Control (EMC), newly connected lighting power load greater than 15kW shall have a control installed that is capable of reducing the lighting power by a minimum of 30% when receiving a demand response signal that is sent out by the local utility.
SIGN LIGHTING CONTROLS
Sign
Voltage:120V ALLELECTRICAL
COMPONENTS12”(Max Height)14’-0”
(Max length)
Manufacture and install face lit channel letters
Trimcaps: ¾” White
Returns: 5” pre-coat black
Faces: White acrylic
Note: Field verify all dims and conditions prior to fab
Illumination: White LEDs / remote power supplies
Raceway: 3” x 5” raceway painted Matthews black 5”Z1
Power supply
120-277VAC
disconnect switch
Grounding wire
secured to
grounding screw
Flex conduit
120-277VAC J-box
Wall stud framing
Wall surface
Trimcap with # 8 screws
Acrylic face
Light Emitting Diods (LED)
Low voltage wire
from LED to LED
3/8” x 5” embedment
lag screws into wall stud
framing every 32” on centers
Aluminum backs
Drilled hole and filled
with silicone to prevent
water penetration
¼” weep holes
Typical Section detail
Scale: nts1
Grounding wire / screw
Alum. backs clinched
to letter returns
Raceway
Z2
Job Name:
Address:
Original Date:
Design Number:
Revisions:
Designer:
Scale: As Noted
This is an original unpublished drawing
created by TNT Electric Sign Co. It is
submitted for your approval. It is not to be
s h o w n t o a n y o n e o u t s i d e o f y o u r
organization, nor is it to be reproduced,
copied or exhibited in any fashion. The
changing of colors, sizes, materials or
illumination method does not alter the
design. Ownership of this design is held by
TNT Electric Sign Co. Authorization to use
this design in any fashion must be obtained
in writing from TNT Electric Sign Co.
© TNT Electric Sign Co. 2019
Note: The colors depicted here are a
graphic representation. Actual colors may
vary. See color specifications.
Page: of 12
3080 E 29TH ST
LONG BEACH, CA 90806
562 595 7725
3080 E 29TH ST
LONG BEACH, CA 90806
562 595 7725
CA LIC. C45 994192CA LIC. C45 994192
Visit us at:
tntelectricsign.com
Visit us at:
tntelectricsign.com
12
06/19/19
3800 & 3810 E. PCH
Sign Program
3800 & 3810 PCH
Corona Del Mar, CA
92625
19-06-3939-R09
R1: sp 7/25/19 revise per attachment
R2: sp 8/26/19 revise per notes
R3: jd 8/30/19 revise per notes
R4: jd 8/30/19 change to channel letters
R5: jd 9/9/19 update install method,
remove sign D
R6: jd 9/10/19 change sign Z to wall
mount
R7: jd 9/10/19 remove sign Z2, add
sign C5
R8: jd 9/12/19 revise per comments
R9: jd 10/10/19 revise per comments
John Nauta
Sales Rep:
Neil McNaught
E-mail:
NeilM@tntelectricsign.com
Sign Elevation Layout
Qty: One (1) Required Scale: ½” = 1’-0”E
Copy: ¾” thick push through white acrylic
Illumination: Existing, to remain as is
Reface existing panel face
Tenant Panel: Routed out .080 aluminum painted to match Matthews Black
Cabinet: Existing, to remain as is
Returns: Existing, to remain as is
Note: Dims per original plans
3"
Side View
Scale: ½” = 1’-0”1 Close Up View Detail
Scale: 1 ½” = 1’-0”2
3"
8'-0"7'-11"1’-0 1/8”
11 1/8”
¾” thick acrylic push through acrylic
.080 routed out aluminum tenant panels
Wall surface
Studs welds behind each tenant panels
and bolted to
.125 routed out aluminum
main panel background
(to hold individual tenant panels)
.080 alum. routed
aluminum tenant panel
with push through copy
SWEAT SAUNA
AURA PILATES
THE HYDRATION ROOM
GABRIEL’S TAILORING
PAZ INGREDIENTS
WELL
BOTANICA FLORAL
FACIAL LOUNGE 5"
Square Footage: 63.33
EXISTING SIGNAGEEXISTING SIGNAGEEXISTING SIGNAGE