Loading...
HomeMy WebLinkAboutBuilding Comments PROJECT REVIEW REQUEST e COMMUNITY DEVELOPMENT DEPARTMENT Planning Division Please Distribute to: Date: December 9, 2019 Building/Dan Kennedy Life Safety Services/Susan Guzzetta EMP/Ben Please return PRR and Plans to Staff Planner Ellingson David Blumenthal, Planning Consultant Public Works - Brine/Keely/Al mend ralo/Cooke 949-644-3200 or dblumenthal(aD-hewportbeachca.gov Applicant: 2510 W Coast Hey LLC Contact: Sean Matsler 949-260-4652 smatsler@coxcastle.com Project Name 2510 West Coast Highway Mixed Use Development Address: 2510 and 2530 West Coast Hey PA2019-249 Proposed mixed use development on a 42,821 square foot lot, which includes demolishing all existing site improvements, constructing a new 10,402 square foot Boutique automobile showroom with a 750 square foot office, plus 36 multi-family residential units (three units will be affordable). REPORT REQUESTED BY: December19, 2019 PLANNING COMMISSION HEARING DATE: TBD Check all that apply: Notes: ❑ No comments on the project a. Plans and calculations must address lateral separation as presented. between adjacent property lines and buildings. ❑ Application of Standard Code b. Plans and soil report must address depth of footing and requirements are not expected to alter the project over-excavation adjacent to property line for shoring_ design. c. Plans must address constructability of property line walls ❑ Recommended conditions of for fire rated construction, including fire rated construction approval are attached. joints. Application of Standard Code requirements or the attached d. Fire rated exterior wall along property line must illustrate conditions of approval will compliance with sections 601, 602, 703, 705.11, 706, 714 substantially impact or alter and 715. Openings are not allowed in property line walls. the design of the project. e. Occupancy and or type of construction fire rated ❑ I contacted the applicant on separations must be illustrated with all fire rated joint and ❑ To schedule an appt. for penetration construction details and specifications.Code review f. Location of mechanical equipment is not part of this ❑ To discuss the following review. All mechanical equipment must be accessible and (see notes) with required: work clearances, anchorage, and supporting members. g. Plans must include all required sound rated construction, detail and specifications between units and common areas per section 1207 CBC. h.Plans must illustrate compliance with emergency escape and rescue opening per section 1030 CBC. Such openings shall open directly into a public way or yard or court that is Tmplt:06/07/19 open to the public way. Opening onto a court that a terminates as a parking structure, vehicular way or parking stalls are not acceptable. Type of construction needs to be defined for the entire building Type IIIA sprinklered building per section 1030 exception#1 is recommended i. Deck areas and open court areas will be classified as an assembly use with an occupant load ranging from 5 — 15 depending on assigned areas at the time of plan check submittal. The required exiting from these spaces must comply with the minimum quantity required per section 1006 CBC. The building's structural design must address the required importance factor"I" base on the risk category base on the nature of occu ancy and load table See Table 1604.5 CBC. j. Decks and open court areas must address landscape loading and waterproof construction. k.All exits must illustrate compliance with Chapter 10 CBC Exits shall not pass under adjacent buildings or structure Exits shall not terminate into a parking_garage or force travel through the parking_garage from the commercial use or residential use. 1. Project will require but not be limited to Shoring, Water Quality Management Plan(WQMP), and a simple SWPPP m. Utility service locations must be coordinated between applicant and utility companies. n. Buildings and facilities must be accessible and comply with Chapter 11 B CBC for the commercial facilities and Chapter 11 A for the residential facilities o. An accessible route must be continuous and unobstructed to all elements and space within the building and connecting to the public sidewalk that is safe for and usable by the public. An accessible route must satisfy sections 1106A, 1108A& 11 B-206 CBC the width, height, slope and surface condition etc (i.e., traversing_parallel and within drive aisles or drainage swales are not allowed to be part of a path of travel). p. Provide soils report prepared by a California licensed Geotechnical Engineer. The report shall foundation desiig recommendations based on the site conditions and State of California mandated Seismic Hazard Mapping Act The site is located within a liquefaction zone. 3z7 � iZ •/o •/ q Si re Ext. Date Tmplt:06/07/19