HomeMy WebLinkAbout20210128_Plans_30x42BRANDON ARCHITECTS
DATE
T-1.0
PROJECT CONTACT
JEFF VAN VOORHIS, AIA
PROJECT NAME
PROJECT ADDRESS
908 W. OCEANFRONT
NEWPORT BEACH, CA 92661
OWNER INFORMATION
908 NB PROPERTY MANAGEMENT LLC
3717 EUCLID AVE.
DALLAS, TX
PROJECT STATUS
CDP
PLAN CHECK NO.
TBD
REVISIONS
NO.
DATE
1/27/2021 HARVEY RESIDENCETITLE SHEET
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
REVISIONS
These documents are the property of BRANDON
ARCHITECTS INC., and are not to be duplicated,
altered or utilized in any ay by any other party
without the expressed authorization of
BRANDON ARCHITECTS. Any unauthorized
duplication or alteration of these documents by
any party is a violation of BRANDON
ARCHITECTS expressed common law copyright
and other property rights thereto, and is subject
to full civil liabilities and penalties. These plans
are also not to be assigned to any third party
without obtaining written authorization and
expressed permission by BRANDON
ARCHITECTS, who shall then be held harmless
and absolved of any liability regarding any use
of these documents by such third party whether
depicted or implied hereon.
7 1 SHEET LIST5SITE INFORMATION
4 AGENCIES & SERVICES
908 W. OCEANFRONT, NEWPORT BEACH CA 92661
HARVEY RESIDENCE
9 DEFERRED SUBMITTALS
8 SPECIAL INSPECTIONS 2 PROJECT DIRECTORY
3 CODE INFORMATION
6 SHORING & EXCAVATION
PROJECT STATISTICS
VICINITY MAP
11 PROJECT DESCRIPTION
10 BRANDON ARCHITECTS, INC.1.LANDSCAPE PLAN; BBQ; FIRE PIT; ACCESSORY STRUCTURES, MASONRY OR CONCRETE WALLS/FENCES; RETAINING WALLS OVER 4
FT. HIGH FROM THE BOTTOM OF THE FOUNDATION TO THE TOP OF WALL; UNDER SEPARATE SUBMITTAL (FOR H.O.A. PURPOSES).
2.POOLS, SPAS, WALLS, FENCES, PATIO COVERS AND OTHER FREESTANDING STRUCTURES REQUIRE SEPARATE REVIEWS AND
PERMITS.
3.SUBMIT SOUND ATTENUATION DESIGN FOR HVAC EQUIPMENT PER ARI STD. 275. SOUND LEVEL NOT TO EXCEED 50DBA (55DBA
WITH TIMER, 65DBA WITH TIMER AND NEIGHBORS CONSENT). LOCATION OF MEASUREMENT TO BE AT ADJACENT PROPERTY PATIO OR
OPENING.
4.FIRE SPRINKLERS REQUIRED, CONTRACTOR TO SUBMIT FIRE SPRINKLER DRAWINGS FOR ARCHITECT'S APPROVAL PRIOR TO
SUBMITTING TO CITY. OBTAIN FIRE SPRINKLER PERMIT PRIOR TO CALLING FOR ROOF SHEATHING INSPECTION.
5.A NOTICE OF INTENT TO DEMOLISH SHALL BE SENT VIA CERTIFIED MAIL TO ADJACENT PROPERTY OWNER(S). SIGNED RETURN
RECEIPT MUST BE PROVIDED TO THE BUILDING DIVISION AT THE TIME OF PERMIT ISSUANCE. DEMOLITION MAY COMMENCE 30 DAYS
AFTER THE DATE OF NOTIFICATION PER NEWPORT BEACH MUNICIPAL CODE SECTION 15.02.120.
NOTE: DEFERRED SUBMITTALS TO BE REVIEWED BY PROJECT ARCHITECT OR ENGINEER OF RECORD AND CERTIFIED PRIOR TO
SUBMITTAL TO LOCAL AGENCY FOR REVIEW.
C.N.B. NOTE: BRANDON ARCHITECTS, INC. IS THE DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE OF THE PROJECT, RESPONSIBLE
FOR REVIEWING AND COORDINATING SUBMITTAL DOCUMENTS PREPARED BY OTHERS, INCLUDING PHASED AND DEFERRED SUBMITTAL
ITEMS, FOR COMPATIBILITY WITH THE DESIGN OF THE BUILDING. (NBMC 15.02.010)
CODES NBMC (NEWPORT BEACH MUNICIPAL CODE
CODES: 2019 CRC, 2019 CFC, 2019 CEC, AND 2019 CMC
CAL GREEN
OCCUPANT LOAD 1 UNIT
OCCUPANCY CLASSIFICATION R-3/U
OCCUPANCY SEPARATION (GARAGE) 1-HR
FLOOR & FLOOR-CEILING N/A
TYPE OF CONSTRUCTION VB - SPRK'R
FIRE SPRINKLER YES
HEIGHT 3 LEVELS
FLOOR AREA REF.7/T-1.0
ALLOWABLE BLDG. AREA (PER CBC TBL.503) N/A
1.REF. STRUCT. SHTS. FOR SPECIAL INSPECTION BY ENGINEER OF RECORD
2.HERS VERIFICATION REQUIRED, REF. T-24 ENERGY CALCULATIONS
1.A CAL-OSHA PERMIT IS REQUIRED FOR EXCAVATIONS DEEPER THAN 5' AND FOR SHORING AND UNDERPINNING. CONTRACTOR TO
PROVIDE A COPY OF OSHA PERMIT.
2.CONTRACTOR SHALL USE THE CITY STANDARD FORM ‘30-DAY NOTICE OF INTENT TO EXCAVATE’ TO NOTIFY ADJACENT PROPERTY
OWNERS BY CERTIFIED MAIL 30 DAYS PRIOR TO STARTING EXCAVATION OR SHORING. CITY STANDARD FORM CAN BE OBTAINED AT:
HTTP://WWW.NEWPORTBEACHCA.GOV/HOME/SHOWDOCUMENT?ID=17395
DIG ALERT: 1.800.227.2600
SOUTHERN CALIFORNIA EDISON: 1.714.895.0246
SOUTHERN CALIFORNIA GAS: 1.800.427.2000
CITY WATER & SEWER: 1.949.644.3011
CITY OF NEWPORT BEACH
PUBLIC WORKS DEPT.: 1.949.644.3311
CITY OF NEWPORT BEACH PLANNING DEPT.:
GENERAL INFOMATION: 1.949.644.3200
ZONING INFORMATION: 1.949.644.3204
CITY OF NEWPORT BEACH BUILDING DEPT.:
GENERAL: 1.949.644.3275
PERMITS: 1.949.644.3288
INSPECTIONS: 1.949.644.3255
NEWPORT BEACH FIRE DEPARTMENT: 1.949.644.3106
ORANGE COUNTY HEALTH SERVICES: 1.714.834.3882
LEGAL DESCRIPTION
APN: 047 281 15
LOT 3, BLOCK 9
TRM_00234
MM_013_36-37
LOT INFORMATION
ZONED: R-1
SITE AREA: 3,652 SF
BUILDABLE AREA: 2,825 SF
TOTAL ALLOWABLE AREA: 2,824 X S.F. = 5,648 SF
REQ'D. OPEN VOLUME: 2,824 X .15 = 423 SF
MAX. THIRD FLOOR ALLOWABLE: 2,824 X .15 = 423 SF
OPEN VOLUME PROVIDED: 439 SF
EXISTING BUILDING INFORMATION
EXISTING SINGLE FAMILY W/ GARAGE TO BE DEMOLISHED
EXISTING S.F. 3,321 S.F.(3 BEDS. TTL.)
ZONING INFORMATION
FRONT SETBACK: 8 FT.
REAR SETBACK: 0 FT.
LEFT SETBACK: 3 FT.
RIGHT SETBACK: 3 FT.
BUILDABLE AREA: 2824 S.F.
THE SUBJECT PROPERTY IS LOCATED IN NEWPORT BEACH, CA AT W OCEANFRONT, FACING THE PACIFIC OCEAN. THE LOT IS
APPROXIMATELY 40’ WIDE BY 90’ DEEP, IT IS ZONED RS-D (SINGLE UNIT RESIDENTIAL) AND IS APPROXIMATELY 3,652 S.F. THE
PROPERTY INCLUDES AN EXISTING RESIDENCE AND GARAGE. CLIENT PROPOSES TO BUILD A NEW 3 STORY SINGLE FAMILY RESIDENCE
OF APPX. 4,600 S.F. INCLUDING AN ATTACHED 3 CAR GARAGE OF APPX. 685 S.F. THE PROJECT WILL BE OF A CONTEMPORARY DESIGN,
INCLUDING BUT NOT LIMITED TO THE FOLLOWING: AMPLE INDOOR/OUTDOOR LIVING SPACES INTEGRATED WITH A MODERN ‘OPEN’
LIVING PLAN WHICH MAXIMIZES THE OCEAN VIEWS FROM LIVING SPACES AS WELL AS OUTDOOR PATIO, BALCONY, AND VIEW DECK. THE
EXTERIOR WILL BE PRIMARILY STUCCO SIDING AND METAL ROOFING, WITH ACCENTS OF WOOD, STONE AND METAL. THE HOUSE WILL
HAVE APPROXIMATELY 5 BEDROOMS, 4.5 BATHROOMS. THE FIRST FLOOR CONTAINS GENEROUS LIVING SPACE, KITCHEN AND DINING
AREA THAT ORIENTED TOWARD THE OCEAN VIEW. THE SECOND LEVEL CONSISTS OF THE MASTER BEDROOM & BATH, 4 BEDROOMS, 4
BATHROOMS AND LAUNDRY. A BONUS ROOM AND A HALF BATH BATHROOM ALONG WITH THE COVERED CABANA AND VIEW DECK ARE
LOCATED ON THE THIRD LEVEL.
TRUE NORTH PROJECT NORTH
OWNER
908 NB PROPERTY MANAGEMENT LLC
DEREK & MEGAN HARVEY
3717 EUCLID AVE.
DALLAS, TX 75205
P: 214.502.1539
CIVIL ENGINEER
FORKERT ENGINEERING &
SURVERYING, INC.
THOMAS M. RUIZ, P.E.
2231 BROOKURST ST., SUITE 203
HUNTINGTON BEACH, CA 92646
P: 714.963.6793
LANDSCAPE DESIGNER
TBD
ARCHITECT
BRANDON ARCHITECTS, INC.
CHRISTOPHER BRANDON, AIA PRINCIPAL
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
P:714.754.4040
WWW.BRANDONARCHITECTS.COM
STRUCTURAL ENGINEER
FMH ENGINEERING, INC.
FADY HAKIM, PE
410 GODDARD SUITE 200
IRVINE, CA 92618
P: 949.245.8000
WWW.FMHENGINEERING.COM
INTERIOR DESIGNER
BLACKBNAD DESIGN
MARKY MEEK
3198 AIRPORT LOOP STUDIO E
COSTA MESA, CA 92626
T. 949.872.2234
F. 949.872.2747
WWW.BLACKBANDDESIGN.COM
ENERGY CONSULTANT
TBD
GENERAL CONTRACTOR
TBD
SURVEYOR
APEX LAND SURVEYING, INC.
PAUL CRAFT, LIC. NO. 8516
HUNTINGTON BEACH, CA 92646
P: 714.488.5006
F: 714.333.4440
GEOTECHNICAL ENGINEER
DAVID WORTHINGTON CEG 2124
EGA CONSULTANTS, LLC.
375-C MONTE VISTA AVE.
COSTA MESA, CA 92627
P: 949.542.9309
F: 949.642.1290
PROJECT NO. BA065.1
TITLE SHEET & GENERAL NOTES
SUR
GRADING/CIVIL DRAWINGS
ARCHITECTURAL SITE PLANS
3D VIEWS
PLANS
ROOF PLAN
EXTERIOR ELEVATIONS
STRUCTURAL DRAWINGS
T-1.0
T-1.1
T-1.2
SUR
C2
C4
A-0.0
A-0.2
A-1.0
A-2.1
A-2.2
A-2.3
A-2.4
A-3.0
A-4.0
S-1
D-1
TITLE SHEET
ARCHITECTURAL GENERAL NOTES
SUPPLEMENTAL DOCUMENTS & NOTES
TOPOGRAPHIC SURVEY
PRECISE GRADING PLAN
EROSION CONTROL PLAN
ARCHITECTURAL SITE PLAN
AREA PLANS
3D VIEWS
FIRST & SECOND LEVEL FLOOR PLAN
THIRD LEVEL FLOOR PLAN
FIRST & SECOND LEVEL DIMENSION PLAN
THIRD LEVEL DIMENSION PLAN
ROOF PLAN
EXTERIOR ELEVATIONS
FOUNDATION PLAN
FOUNDATION DETAILS
BUILDING AREA
LIVING
GARAGE
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
3-CAR GARAGE
1,735
2,376
422
4,532 sq ft
735
735 sq ft
5,267 sq ft
PA2021-013
BRANDON ARCHITECTS
DATE
T-1.1
PROJECT CONTACT
JEFF VAN VOORHIS, AIA
PROJECT NAME
PROJECT ADDRESS
908 W. OCEANFRONT
NEWPORT BEACH, CA 92661
OWNER INFORMATION
908 NB PROPERTY MANAGEMENT LLC
3717 EUCLID AVE.
DALLAS, TX
PROJECT STATUS
CDP
PLAN CHECK NO.
TBD
REVISIONS
NO.
DATE
1/27/2021 HARVEY RESIDENCEARCHITECTURAL
GENERAL NOTES
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
REVISIONS
These documents are the property of BRANDON
ARCHITECTS INC., and are not to be duplicated,
altered or utilized in any ay by any other party
without the expressed authorization of
BRANDON ARCHITECTS. Any unauthorized
duplication or alteration of these documents by
any party is a violation of BRANDON
ARCHITECTS expressed common law copyright
and other property rights thereto, and is subject
to full civil liabilities and penalties. These plans
are also not to be assigned to any third party
without obtaining written authorization and
expressed permission by BRANDON
ARCHITECTS, who shall then be held harmless
and absolved of any liability regarding any use
of these documents by such third party whether
depicted or implied hereon.
ABBREVIATIONS
& AND
. ANGLE
@ AT
C.L. CENTERLINE
DIAMETER, ROUND
. PERPENDICULAR
# POUND OR NUMBER
A.B. ANCHOR BOLT
ABV. ABOVE
A/C. AIR CONDITIONING
A.C. ASPHALT CONCRETE
ACOUS ACOUSTICAL
A.D. AREA DRAIN
ADH. ADHESIVE
ADJ. ADJUSTABLE, ADJACENT
AL. ALUMINUM
ALT. ALTERNATE
ANOD. ANODIZED
A.P. ACCESS PANEL
APPX. APPROXIMATE
APPV'D. APPROVED
ARCH. ARCHITECTURAL,ARCHITECT
ASB. ASBESTOS
ASSY. ASSEMBLY
AUTO. AUTOMATIC
B. BATHROOM
BD. BOARD
BEL. BELOW
BET. BETWEEN
BIT. BITUMINOUS
BLDG. BUILDING
BLK. BLOCK
BLK'G. BLOCKING
BM. BEAM
B.O. BY OWNER, BY OTHERS
BOT. BOTTOM
BR. BEDROOM
B.W. BACK OF WALL, BOTTOM OF WALL
CAB. CABINET
C.B. CATCH BASIN
C.B.C. CALIFORNIA BUILDING CODE
C.R.C. CALIFORNIA RESIDENTIAL CODE
CEM. CEMENT
C.G. CORNER GUARD
CHAN. CHANNEL
CHG. CHANGE
C.I. CAST IRON
C.J. CONTROL / CONSTRUCT./CEILING JOINT
CLG. CEILING
CLKG. CAULKING
CLR. CLEAR, CLEARANCE
CNTR. COUNTER
CONC. CONCRETE
COND. CONDITION
CONST. CONSTRUCT, CONSTRUCTION
CORR. CORRIDOR, CORROSIVE
CTSK. COUNTER SINK, COUNTERSUNK
CTR. CENTER
DBL. DOUBLE
DECO. DECORATIVE
DEPT. DEPARTMENT
DET. DETAIL
D.F. DRINKING FOUNTAIN, DOUGLAS FIR
DIA. DIAMETER
DIAG. DIAGONAL
DIM. DIMENSION
DN. DOWN
DR. DOOR
D.S. DOWNSPOUT
D.S.P. DRY STANDPIPE
DWG. DRAWING(S)
E. EXISTING, EAST, ENTRY, EACH
E.J. EXPANSION JOINT
ELEC. ELECTRIC, ELECTRICAL
ELEV. ELEVATOR
EMER. EMERGENCY
ENCL. ENCLOSED, ENCLOSURE
E.P. ELECTRICAL PANEL, END POINT
EQ. EQUAL
EQV. EQUIVALENT
EQUIP. EQUIPMENT
E.W. EACH WAY
EXH. EXHAUST
EXPO. EXPOSED
EXT. EXTERIOR
E.G. EXISTING GRADE
F. FIXED
F.A. FIRE ALARM
FAC. FACTORY
F.C.O. FLOOR CLEAN OUT
F.D. FLOOR DRAIN
FDN. FOUNDATION
F.E. FIRE EXTINGUISHER
F.E.C. FIRE EXTINGUISHER CABINET
F.G. FINISH GRADE
FIX./FIXT. FIXTURE
F.J. FLOOR JOIST
F.L. FLOW LINE
FLASH. FLASHING
FLR. FLOOR
FLUOR. FLUORESCENT
F.O.C. FACE OF CONCRETE/CURB
F.O.F. FACE OF FINISH
F.O.S. FACE OF STUD / STRUCTURE / SHEATHING
F.O.M. FACE OF MASONRY
FP. FIREPLACE
F.S. FLOOR SINK, FINISH SURFACE
FT. FOOT, FEET
FTG. FOOTING
FURR. FURRING
FUT. FUTURE
F.V. FIELD VERIFY
GA. GAUGE
GALV. GALVANIZED
G.B. GRAB BAR, GRADE BEAM
G.C. GENERAL CONTRACTOR
GEN. GENERAL
G.F.I. GROUND FAULT INTERRUPT
G.I. GALVANIZED IRON
G.L.B. GLU-LAM BEAM
GND. GROUND
GR. GRADE
GYP. GYPSUM
G.P. GRADE PLANE
H./HT. HIGH, HEIGHT
H.B. HOSE BIBB
H.C. HOLLOW CORE
HD. HARD, HEAD
HDR. HEADER
HDWD. HARDWOOD
HDWR. HARDWARE
H.M. HOLLOW METAL
HORIZ. HORIZONTAL
HR. HOUR
HVAC HEATING VENTILATING AIR
CONDITIONING
I.D. INTERIOR DESIGNER, INSIDE DIAMETER/DIMENSION
IN. INCH
INSUL. INSULATION
INT. INTERIOR
INV. INVERT/INVERTED
JAN. JANITOR
JT. JOINT
JST. JOIST
KIT. KITCHEN
L. LOW, LINEN
L.A. LANDSCAPED AREA
LAB. LABORATORY
LAM. LAMINATED
LAV. LAVATORY
LBS. POUNDS
LFA. LOAD FROM ABOVE
L.H. LEFT HAND
LKR. LOCKER
LT. LIGHT
LUM. LUMINOUS, LUMENS
MAINT. MAINTENANCE
MAS. MASONRY
MAT. MATERIAL
MAX. MAXIMUM
M.B. METAL BOLT
M.C. MEDICINE CABINET
MECH. MECHANICAL
MEMB. MEMBRANE
MET./MTL. METAL
MFGR. MANUFACTURER
M.H. MANHOLE
MIN. MINIMUM
MIR. MIRROR
MISC. MISCELLANEOUS
M.O. MASONRY OPENING
MT. MOUNTED
MUL. MULLION
N. NEW, NORTH
NAT. NATURAL
N.I.C. NOT IN CONTRACT, CONTACT
N.G. NATURAL GRADE
NO. NUMBER
NOM. NOMINAL
N.T.S. NOT TO SCALE
O/. OVER
O.A. OVERALL
OBS. OBSCURE
O.C. ON CENTER
O.D. OUTSIDE DIAMETER, DIMENSION
O.F.D. OVERFLOW DRAIN
OFF. OFFICE
OPNG. OPENING
OPP. OPPOSITE
PERIM. PERIMETER
PL. PROPERTY LINE, PLATE
P.LAM. PLASTIC LAMINATE
PLAS. PLASTER
PLUMB. PLUMBING
PLYWD. PLYWOOD
PNT. PAINT(ED)
P.O.C. POINT OF CONTACT, CONNECTION
PR. PAIR
PROJ. PROJECTION
PSL. PARALLEL STRAND LAMINATE
PT. POINT
R.A. RETURN AIR
RAD. RADIUS
R.D. ROOF DRAIN
R.D.L. ROOF DRAIN LEADER
RECPT. RECEPTACLE
RECT. RECTANGLE, RECTANGULAR
REF. REFERENCE
REFR./R. REFRIGERATOR
REG. REGULAR, REGISTER
REINF. REINFORCE(D), REINFORCEMENT
REQ'D. REQUIRED
RESIL. RESILIENT
RET. RETAIN(ING), RETURN
RM. ROOM
R.O. ROUGH OPENING
R.R. ROOF RAFTER
RWD. REDWOOD
S. SOUTH
S.A. SUPPLY AIR
S.C. SOLID CORE
S.C.D. SEAT COVER DISPENSER
SCHED. SCHEDULE
S.D. SUBDRAIN, SOAP DISPENSER
SEC. SECTION
SEL. SELECT(ED)
SH. SHELF
SHT. SHEET
SHT'G. SHEATHING
SIM. SIMILAR
SIMP. SIMPSON
S.J. SOFFIT JOIST
S.S. STAINLESS STEEL
S.SK. SERVICE SINK
STA. STATION
STD. STANDARD
STL. STEEL
STOR. STORAGE
STRUCT. STRUCTURE, STRUCTURAL
SUSP. SUSPEND(ED)
SYM. SYMMETRICAL
SYS. SYSTEM
T. TREAD, TRASH
T.C. TOP OF CURB
T.CL. TIME CLOCK
TEL. TELEPHONE
TEMP. TEMPERED
TER. TERRAZZO
T & G TONGUE & GROOVE
THK. THICK, THICKNESS
T.P. TOP OF PAVING
T.PL. TOP OF PLATE
T.O.S. TOP OF STRUCTURE, SHEATHING, SLAB
TRANS. TRANSFORMER
T.S. TOP OF STEP
T.W. TOP OF WALL
TYP. TYPICAL
U. UNDER
U.B.C. UNIFORMBUILDING CODE
U.G. UNDERGROUND
U.L. UNDERWRITER'S LABORATORY
UNF. UNFINISHED
U.N.O. UNLESS NOTED OTHERWISE
UR. URINAL
V./VERT. VERTICAL
VENT. VENTILATION, VENTILATING
VER. VERIFY
V.T.R. VENT THROUGH ROOF
W. WEST, WIDTH, WASHER
W/. WITH
WD. WOOD
W.H. WATER HEATER
W.C. WATER CLOSET
W.I. WROUGHT IRON
WP. WATERPROOF(ING)
W.W.M. WELDED WIRE MESH
DEFINITIONS: (AS USED IN THESE SPECIFICATIONS)
OWNER SHALL MEAN: 908 NB PROPERTY MANAGEMENT LLC
ARCHITECT SHALL MEAN: BRANDON ARCHITECTS, INC., JEFF VAN VOORHIS, AIA
CONTRACTOR SHALL MEAN: LICENSED GENERAL CONTRACTOR HIRED TO PERFORM THE WORK UNDER THIS CONTRACT
SPECIFICATIONS SHALL MEAN: WRITTEN SPECIFICATIONS IN THE PLANS OR THE "PROJECT MANUAL" (IF PROVIDED FOR THIS PROJECT)
CONTACT DOCUMENTS SHALL MEAN: WORKING DRAWINGS APPROVED FOR BUILDING PERMIT, PLUS ANY CHANGE ORDERS OR ADDENDA TO SAME.
ARCHITECTURAL GENERAL NOTES:
1. CODES/GENERAL PROVISIONS: ALL WORK, CONSTRUCTION AND MATERIALS SHALL COMPLY WITH ALL PROVISIONS OF THE APPLICABLE BUILDING CODES AND WITH OTHER RULES, REGULATIONS AND ORDINANCES GOVERNING THE PLACE OF CONSTRUCTION. IT IS THE
RESPONSIBILITY OF THE CONTRACTOR, SUB-CONTRACTORS, AND ANYONE SUPPLYING LABOR AND/OR MATERIAL TO BRING TO THE ATTENTION OF THE ARCHITECT (VERBALLY AND IN WRITING) ANY KNOWN DISCREPANCIES OR CONFLICT BETWEEN THE REQUIREMENTS OF THESE CODES
AND THE CONTRACT DOCUMENTS (DRAWINGS). THE APPLICABLE CODES SHALL INCLUDE, BUT SHALL NOT BE LIMITED TO THOSE AS LISTED IN "CODE REVIEW" BOX. (T-1)
ALL WORK SHALL BE PERFORMED SO AS TO COMPLY WITH ALL LEGAL AND INDUSTRY REQUIREMENTS AND STANDARDS INCLUDING THE FOLLOWING:
- THE BUILDING CODES, 2019 EDITIONS, AS ADOPTED BY CALIFORNIA, ALL APPLICABLE RELATED SPECIALTY CODES.
- THE FUNCTIONALITY STANDARDS SET FORTH IN TITLE 7 OF THE CALIFORNIA CIVIL CODE (THE "RIGHT TO REPAIR ACT").
- ANY WORK TIME RESTRICTIONS IMPOSED BY THE CITY OF NEWPORT BEACH.
THE MANUFACTURER'S REQUIREMENTS OF RECOMMENDATIONS FOR ANY INCORPORATED PRODUCTS.
2. FEES: CONTRACTOR AND HIS SUB-CONTRACTORS SHALL OBTAIN AND PAY FOR ALL PERMITS, LICENSES, CONSTRUCTION TAXES AND FEES REQUIRED BY CITY, COUNTY AND STATE LAWS EXCEPT THE GENERAL BUILDING PLAN CHECK FEE AND REQUIRED REFUNDABLE DEPOSITS
WHICH WILL BE PAID BY THE OWNER. CONTRACTOR SHALL ARRANGE FOR ALL METER INSTALLATIONS AND PAY ALL FEES FOR SAID METERS. CONTRACTOR SHALL PROVIDE TEMPORARY TOILET FACILITIES AND EROSION CONTROL MEASURES AS REQUIRED BY STATE AND LOCAL
BUILDING CODE.
3. CONTRACTOR'S SURVEY: CONTRACTOR SHALL VISIT THE JOB SITE AND BE RESPONSIBLE FOR HAVING COMPLETE KNOWLEDGE OF EXISTING CONDITIONS. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS WITH THOSE SHOWN ON THE DRAWINGS AND SHALL VERIFY GRADES,
CONDITIONS AND DIMENSIONS PRIOR TO COMMENCING DEMOLITION AND CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY VERBALLY AND IN WRITING OF DISCREPANCIES BETWEEN ACTUAL CONDITIONS AND THOSE DEPICTED IN THE CONTRACT
DOCUMENTS. CONTRACTOR SHALL NOTIFY ARCHITECT IMMEDIATELY VERBALLY AND IN WRITING OF ANY DISCREPANCIES FOUND WITHIN THE DRAWINGS AND SPECIFICATIONS.
4. COORDINATION OF CONSTRUCTION: CONTRACTOR IS SOLELY RESPONSIBLE FOR THE ACCURACY OF DETAILS; FOR CONFIRMING AND COORDINATING ALL QUANTITIES AND DIMENSIONS; FOR SELECTING FABRICATION PROCESSES; FOR TECHNIQUES OF ASSEMBLY AND
PERFORMANCE OF ALL WORK IN A SAFE AND SATISFACTORY MANNER. CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF ALL WORK INCLUDING THAT OF THE SUB-CONTRACTORS. CONTRACTOR SHALL PROVIDE SUPERVISION OF THE JOB DURING ALL PHASES OF
CONSTRUCTION ACTIVITIES. A COMPETENT SUPERINTENDENT SHALL BE SELECTED BY THE CONTRACTOR AND SHALL BE IN CHARGE OF THE JOB UNTIL ITS COMPLETION. CONTRACTOR AGREES TO BIND EVERY SUB-CONTRACTOR BY THE TERMS OF THE CONTRACT AS FAR AS SUCH
TERMS ARE APPLICABLE TO THE SUB-CONTRACTOR'S WORK.
5. CLEAN-UP: ALL SUBCONTRACTORS SHALL BE RESPONSIBLE FOR THE DAILY REMOVAL OF ALL DEBRIS ACCUMULATED AS A RESULT OF THEIR OPERATIONS. ALL SCRAP DEBRIS AND OTHER EXCESS MATERIAL SHALL BE LAWFULLY REMOVED FROM THE SITE, UNLESS OTHERWISE
DIRECTED BY THE CONTRACTOR.
6. TESTS AND PERMITS: CONTRACTOR SHALL ARRANGE FOR, AND SECURE REQUIRED TESTS, PERMITS AND INSPECTIONS, AND SHALL BEAR COSTS FOR SAME.
7. GUARANTEES: CONTRACTOR SHALL GUARANTEE ALL WORK, MATERIALS AND PRODUCTS FOR ONE YEAR AFTER THE DATE OF ACCEPTANCE OF THE WORK AND CONTRACTOR SHALL REPAIR OR REPLACE, OR CAUSE TO BE REPAIRED OR REPLACED ANY OR ALL SUCH WORK
TOGETHER WITH ANY OTHER WORK WHICH MAY BE DISPLACED IN DOING SO, THAT MAY PROVE DEFECTIVE WITHIN ONE YEAR, WITHOUT ADDITIONAL EXPENSE; ORDINARY WEAR AND TEAR, UNUSUAL ABUSE OR NEGLECT IS EXCEPTED. EXCEPTIONS TO ONE YEAR GUARANTEE ARE
SPECIFIED IN OTHER SECTIONS OF THE PROJECT MANUAL OR DRAWINGS. STATE LAW, OR MANUFACTURER'S GUARANTEE SHALL GOVERN IF LENGTH AND TYPES OF GUARANTEES ARE MORE STRICT OR FOR LONGER PERIODS. IT IS UNDERSTOOD BY CONTRACTOR THAT IT IS HIS
RESPONSIBILITY TO PROVIDE MATERIALS AND CONSTRUCTION WHICH WILL YIELD A REASONABLE VALUE OVER A PERIOD OF TIME WHICH MAY EXCEED THE SPECIFIED GUARANTEE AND WARRANTY PERIODS. CONTRACTOR SHALL BE RESPONSIBLE FOR A WEATHER TIGHT BUILDING,
FREE FROM DEFECTS OF MATERIALS AND WORKMANSHIP. EACH SUB-CONTRACTOR SHALL PROVIDE A WRITTEN GUARANTEE STATING THAT WORK EXECUTED BY HIM IS FREE AND WILL REMAIN FREE FROM DEFECTS OF MATERIALS AND WORKMANSHIP FOR ONE YEAR FROM DATE OF
ACCEPTANCE OF HIS WORK BY OWNER, AND THAT REPAIR AND REPLACEMENT OF SUCH DEFECTIVE WORK AND ALL OTHER WORK DAMAGED AS A RESULT THEREBY WILL BE EXECUTED IN A TIMELY MANNER AT THE CONVENIENCE OF THE OWNER AND WITHOUT COST TO OWNER.
8. WAIVER OF LIENS: CONTRACTOR SHALL PROVIDE CERTIFIED RELEASE OF LIENS BY ALL SUBCONTRACTORS AND SUPPLIERS, OR ANYONE PROVIDING MATERIALS AND/OR LABOR AS THEY BECOME AVAILABLE.
9. ROLL OF ARCHITECT DURING CONSTRUCTION: THE ARCHITECT WILL NOT ACT AS THE OWNER'S REPRESENTATIVE DURING CONSTRUCTION. ARCHITECT WILL ADVISE AND CONSULT WITH OWNER. ARCHITECT WILL OBSERVE CONSTRUCTION PER HIS AGREEMENT WITH OWNER AND
RENDER INTERPRETATIONS NECESSARY FOR THE PROPER EXECUTION OR PROGRESS OF THE WORK IN ACCORDANCE WITH THE INTENT OF THE PLANS AND SPECIFICATIONS. ARCHITECT WILL NOT BE RESPONSIBLE OR HAVE CONTROL OR CHARGE OVER THE ACTS OR OMISSIONS,
CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS, OF THE CONTRACTOR, SUB-CONTRACTORS, OR ANY OF THEIR AGENTS OR EMPLOYEES, OR ANY OTHER PERSONS PERFORMING ANY OF THE WORK. ANY
VERBAL INSTRUCTION OR AUTHORIZATION THAT IS CONFIRMED BY LETTER, MEETING NOTE, MEMORANDA, OR THE LIKE, (WITH A COPY SENT TO THE OWNER, OR THE OWNER'S REPRESENTATIVE) & THERE IS NO EXCEPTION TAKEN WITHIN (10) CALENDAR DAYS, SHALL BE DEEMED
EQUIVALENT TO RECEIPT OF WRITTEN INSTRUCTION, APPROVAL AND AUTHORIZATION FROM THE OWNER.
10. A.I.A. GENERAL CONDITIONS: THE CURRENT GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION PUBLISHED BY THE AMERICAN INSTITUTE OF ARCHITECTS SHALL APPLY AS THOUGH IT WERE PART OF THESE DOCUMENTS UNLESS SPECIFICALLY MODIFIED IN THE
OWNER/CONTRACTOR AGREEMENT. A COPY OF SAID GENERAL CONDITIONS MAY BE OBTAINED FROM THE ARCHITECT UPON REQUEST. THE NOTES CONTAINED IN THESE "GENERAL NOTES" ON THIS SHEET ARE INTENDED TO SUMMARIZE AND COMPLIMENT THE A.I.A. GENERAL
CONDITIONS. THE A.I.A. GENERAL CONDITIONS SHALL TAKE PRECEDENCE OVER THESE NOTES SHOULD A CONFLICT IN WORDING OCCUR.
11. EXTRAS: OWNER MAY ORDER EXTRA WORK OR MAKE CHANGES BY ALTERING, ADDING TO OR DEDUCTING FROM THE WORK, THE CONTRACT SUM BEING ADJUSTED TO THE MUTUAL SATISFACTION OF THE OWNER, ARCHITECT AND CONTRACTOR. BEFORE ANY CHANGES ARE
BEGUN, THE ADDED OR DEDUCTED SUM SHALL BE PRESENTED TO OWNER IN WRITING FOR APPROVAL.
12. SUBSTITUTIONS: SUBSTITUTIONS OF MATERIALS OR METHODS PROPOSED BY THE CONTRACTOR OR HIS SUB-CONTRACTORS CONTRARY TO DRAWINGS AND SPECIFICATIONS SHALL BE SUBMITTED TO ARCHITECT IN WRITING FOR APPROVAL OR DENIAL. IF MORE THAN ONE
MANUFACTURER IS SPECIFIED IN THE PLANS OR SPECIFICATIONS, IT SHALL BE THE CONTRACTOR'S OPTION TO SELECT THE ONE WHICH HE MAY DESIRE. IF MORE THAN ONE FINISH OR STYLE IS AVAILABLE IN THE ITEM SPECIFIED, CONTRACTOR SHALL BE OBLIGATED TO NOTIFY
ARCHITECT VERBALLY AND IN WRITING OF THIS FACT FOR ARCHITECT'S AND OWNER'S DECISION. WHERE THE TERM "OR EQUAL" IS USED IN DRAWINGS OR SPECS IT SHALL BE UNDERSTOOD THAT THE REFERENCE IS MADE SUBJECT TO THE RULING AND JUDGMENT OF THE ARCHITECT
AND SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW AND APPROVAL. ACTUAL SAMPLES OF THE SUBSTITUTIONS SHALL ALSO BE SUBMITTED TO THE ARCHITECT FOR REVIEW AND APPROVAL.
13. INSURANCE: CONTRACTOR SHALL CARRY GENERAL LIABILITY INSURANCE WITH BROAD FORM PROPERTY DAMAGE ENDORSEMENT AND CONTINGENT LIABILITY ENDORSEMENT. OWNER AND ARCHITECT SHALL BE LISTED AS ADDITIONAL INSURERS UNDER THE POLICY WITH
WAIVER OF SUBROGATION. CONTRACTOR SHALL FURNISH OWNER WITH A CERTIFICATE OF INSURANCE WITH A 30 DAY NOTICE OF CANCELLATION. OWNER SHALL OBTAIN A BUILDER'S RISK POLICY WITH ARCHITECT NAMED AS AN ADDITIONAL INSURED WITH WAIVER OF SUBROGATION.
14. SCOPE OF DRAWINGS AND SPECIFICATIONS: THESE DRAWINGS AND SPECIFICATIONS SHALL BE INTENDED TO SHOW AND DESCRIBE DETAILS FOR A CONSTRUCTIBLE BUILDING. PARTS AND DETAILS NOT FULLY SHOWN OR DESCRIBED SHALL BE DETAILED AND EXECUTED
ACCORDING TO STANDARD FIRST CLASS PRACTICE AND IN SIMILAR MANNER AND SPIRIT OF THE DETAILS WHICH ARE SHOWN ON THE DRAWINGS AND/OR DESCRIBED IN THE PROJECT MANUAL. IF CONTRACTOR OR SUB-CONTRACTOR FINDS ANY DETAILS WHICH, IN HIS OPINION, ARE
UNSOUND, UNSAFE, OR NOT WATERPROOF, IT IS HIS DUTY TO NOTIFY ARCHITECT IN WRITING OF THIS FACT. IF WORK IS PERFORMED AS DETAILED, IT WILL BE ASSUMED THAT THERE ARE NO OBJECTIONS TO THE DETAIL. ACCURACY OF ALL DIMENSIONS SHALL BE CHECKED. NO
EXTRA COMPENSATION WILL BE ALLOWED FOR DIFFERENCE BETWEEN ACTUAL DIMENSIONS AND THOSE INDICATED ON THE DRAWINGS. IN USING THESE PLAN FOR BIDDING OR CONSTRUCTION PURPOSES, ALL CONTRACTORS ARE REQUIRED TO REVIEW AND TREAT THEM AS A WHOLE
IN ORDER TO IDENTIFY ALL REQUIREMENTS THAT DIRECTLY OR INDIRECTLY AFFECT THEIR PORTION OF THE WORK, EVEN REQUIREMENTS LOCATED IN SECTIONS DESIGNATED AS APPLICABLE TO OTHER TRADES. IN CASE OF CONFLICTS, THE AFFECTED CONTRACTOR IS REQUIRED TO
EITHER OBTAIN DIRECTION FROM AN APPROPRIATE REPRESENTATIVE OF THE OWNER, OR OTHERWISE TO APPLY THE MORE STRINGENT STANDARD. THESE PLANS ARE INTENDED TO SET FORTH THE REQUIREMENTS FOR CONSTRUCTION IN ONLY AN INDUSTRY-STANDARD LEVEL OF
QUALITY AND DETAIL, AND THE ARE INTENDED TO BE SUPPLEMENTED BY APPROPRIATE REQUESTS FOR CLARIFICATION AND INFORMATION. ERRORS AND OMISSIONS ARE TO BE EXPECTED AND ANTICIPATED, AND ALL CONTRACTORS ARE REQUIRED TO CAREFULLY REVIEW THESE
PLANS FOR ERRORS AND OMISSIONS AND TO BRING THESE ERRORS AND OMISSIONS TO THE ATTENTION OF A APPROPRIATE OWNER & ARCHITECT IN WRITING IN A TIMELY MANNER; AND ANY CONTRACTOR WHO FAILS TO DO SO BEFORE BIDDING OR OTHERWISE PROCEEDING
ASSUMES THE RISK OF ANY CONSEQUENCES. SCALED DIMENSIONS SHOULD BE CONSIDERED ONLY APPROXIMATE; AND IN ANY DIMENSIONS BEFORE PROCEEDING WITH ANY AFFECTED PROCUREMENT, FABRICATION OR CONSTRUCTION. SCHEMATIC PLANS ARE INTENDED ONLY TO
DEMONSTRATE THE RELATIONSHIP AMONG COMPONENT PARTS, AND NOT TO DEPICT SPECIFIC LOCATIONS (E.G. SCHEMATIC ELECTRICAL PLANS).
15. DIMENSIONS ON DRAWINGS: FIGURED DIMENSIONS SHALL BE FOLLOWED IN PREFERENCE TO SCALE, AND DETAIL DRAWINGS IN PREFERENCE TO SMALL SCALE DRAWINGS. SUB-CONTRACTOR AND CONTRACTOR SHALL CHECK ACCURACY OF ALL DIMENSIONS IN THE FIELD PRIOR
TO ANY WORK BEING CONSTRUCTED OR MATERIALS OR PRODUCTS FABRICATED OR ORDERED. SPECIFICATIONS AND WRITTEN NOTES AND SCHEDULES ON DRAWINGS SHALL BE FOLLOWED IN PREFERENCE TO INFORMATION FURNISHED IN THE FORM OF LINE DRAWINGS. DETAILED
DRAWINGS FURNISHED DURING CONSTRUCTION OR APPROVED BY CONTRACTOR OR ARCHITECT ARE TO BE CONSIDERED EXPLANATORY AND NOT AS CHANGES TO DRAWINGS AND SPECIFICATIONS. NOTES, FIGURES AND DETAILS ON SAID DRAWINGS SHALL BE FOLLOWED AND
EXECUTED AS IF PART OF THESE DOCUMENTS. DRAWINGS ARE NOT TO BE SCALED UNLESS PERMITTED BY THE ARCHITECT. DIMENSIONS SHALL GOVERN. ALL EXTERIOR DIMENSIONS ARE BASED ON NOMINAL SIZES OF MEMBERS AND ARE GIVEN TO THE OUTER FACE OF SUCH
MEMBERS, UNLESS OTHERWISE NOTED ON DRAWINGS. INTERIOR PARTITIONS ARE DIMENSIONED FROM FACE OF STRUCTURE TO FACE OF STRUCTURE UNLESS OTHERWISE NOTED ON DRAWINGS. WHERE DIMENSION IS LABELED "CLEAR" IT IS TAKEN FROM THE FACE OF FINISH TO
FACE OF FINISH OF EACH MATERIAL. PLUS OR MINUS (+/-) DIMENSIONS SHALL NOT VARY BY MORE THAN 2" WITHOUT APPROVAL BY ARCHITECT. WALL ANGLES ARE EITHER 90° OR 45° UNLESS NOTED OTHERWISE.
16. SUBMITTALS, MEETING NOTES, BULLETINS, AND MEMOS: SUBMITTALS WILL BE REVIEWED BY THE ARCHITECT, IF AT ALL, ONLY PURSUANT TO THE INDUSTRY-STANDARD PROTOCOL SET FORTH IN AIA DOCUMENT A201-1997; AND IN NO EVENT WILL THE SUBMITTAL REVIEW
PROCESS RELIEVE OR LESSEN THE SUBMITTING CONTRACTOR'S RESPONSIBILITY FOR AN INAPPROPRIATE SUBMITTAL. ARCHITECT, FROM TIME TO TIME, WILL ISSUE CONSTRUCTION NOTES OR MEMOS REGARDING CONSTRUCTION ISSUES THAT HAVE ARISEN SINCE THE DRAWINGS AND
SPECIFICATIONS WERE COMPLETED. CONTRACTOR SHALL REVIEW THESE WRITTEN DOCUMENTS AND INCORPORATE THEM INTO THE PROJECT. ANY QUESTIONS OR OBJECTIONS AS TO THE INTENT OF THE WRITTEN DOCUMENT ITEMS WILL BE BROUGHT TO THE IMMEDIATE ATTENTION
OF THE ARCHITECT FOR DISCUSSION AND OR CLARIFICATION. ANY ITEM THAT RESULTS IN A CHANGE TO THE COST OR TIMING OF THE PROJECT SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE OWNER & ARCHITECT PRIOR TO EXECUTING. CONTRACTOR SHALL SUBMIT
FABRICATION SHOP DRAWINGS TO THE ARCHITECT FOR APPROVAL PRIOR TO ORDERING AND/OR FABRICATION. CONTRACTOR SHALL SUBMIT MANUFACTURER'S CUTS FOR ALL FIXTURES AND EQUIPMENT CALLED FOR ON THE CONSTRUCTION DOCUMENTS TO ARCHITECT INCLUDING
BUT NOT LIMITED TO LIGHT FIXTURES, HARDWARE, PLUMBING FIXTURES, KITCHEN EQUIPMENT, ETC. BY SUBMITTING SHOP DRAWINGS AND PRODUCT DATA, THE CONTRACTOR REPRESENTS THAT HE/SHE HAS VERIFIED FIELD CONDITIONS, DIMENSIONS AND RELATED CONSTRUCTION
AND HAS COORDINATED THE SUBMISSION CONSTRUCTION WITH THE REQUIREMENTS OF ALL OTHER RELATED WORK IN THE CONSTRUCTION DOCUMENTS. ALL SHOP DRAWINGS AND CUTS MARKED "REVIEWED" BY ARCHITECT, ARE FOR VERIFICATION OF ADHERENCE TO THE DESIGN
INTENT ONLY. THE CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR ALL MEANS AND METHODS AND ERRORS AND OMISSIONS ON THEIR DRAWINGS. CONTRACTOR TO SUBMIT A COMPLETE SHOP DRAWINGS AND OR SUBMITTAL FOR APPROVAL BEFORE COMMENCING FABRICATION
AND/OR INSTALLATION OF ALL APPLICABLE ITEMS. ALL SHOP DRAWINGS DIMENSIONS SHALL BE FIELD VERIFIED, REVIEWED AND APPROVED BY CONTRACTOR BEFORE SUBMITTAL. SHOP DRAWINGS WHICH ARE INCOMPLETE OR LACKING SUFFICIENT INFORMATION WILL BE RETURNED
WITHOUT REVIEW. SUBMIT SAMPLES FOR INITIAL SELECTION PURPOSES OF ACTUAL VENEERS SHOWING A FULL RANGE OR GRAIN VARIATION, FINISH AND PATTERNS PROPOSED. SUBMIT SAMPLES AS REQUIRED UNTIL APPROVED BY ARCHITECT. SAMPLES SHALL BE 12" X 12" MIN.,
ONE UNIT OF EACH TYPE AND FINISH.
17. ERRORS AND OMISSIONS: ERRORS OR OMISSIONS WHICH APPEAR ON THE DRAWINGS, IN SPECIFICATIONS OR OTHER CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT BY THE CONTRACTOR AND TO THE CONTRACTOR BY THE SUB-
CONTRACTOR IN WRITING. IN EVENT OF FAILURE OF SUB-CONTRACTOR TO GIVE SUCH WRITTEN NOTIFICATION BEFORE CONSTRUCTION OR FABRICATIONS OF THE WORK, HE WILL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY SUCH ERRORS OR OMISSIONS AND THE COSTS OF
RECTIFYING SAME. HOWEVER, DRAWINGS AND SPECIFICATIONS ARE COMPLEMENTARY AND WORK CALLED FOR ON ONE AND NOT THE OTHER SHALL BE PROVIDED AS THOUGH FULLY SET FORTH IN BOTH.
18. BARRICADES: CONTRACTOR SHALL ERECT AND PROPERLY MAINTAIN AT ALL TIMES AS REQUIRED BY CONDITIONS AND PROGRESS OF THE WORK, ALL NECESSARY PROTECTIVE BARRICADES, FENCES AND OTHER SAFEGUARDS FOR THE PROTECTION OF THE WORKERS AND THE
PUBLIC. THESE BARRICADES SHALL BE CONSTRUCTED AND BE LOCATED AS SHALL BE DETERMINED BY LOCAL AUTHORITIES AND CODES.
19. TEMPORARY BRACING: AT ALL TIMES DURING CONSTRUCTION ACTIVITIES OR ERECTION OF PROJECT OR ITS COMPONENT PARTS, PRIOR TO COMPLETION OF THE STRUCTURAL FRAME OR REPLACEMENT AND PERMANENT CONNECTION OF COMPONENT MEMBERS TO THE
STRUCTURAL FRAME, SUB-CONTRACTORS SHALL PROVIDE, INSTALL AND MAINTAIN PROPERLY DESIGNED AND CONSTRUCTED TEMPORARY BRACING OF ADEQUATE STRENGTH TO PREVENT DISLOCATION, DISTORTION, CRACKING, FALLING OFF, OR ANY OTHER DAMAGE TO WORK OR
ANY OF ITS COMPONENT PARTS DUE TO FORESEEABLE NORMAL AS WELL AS NOT FORESEEABLE EXCESSIVE WIND AND EARTHQUAKE FORCES WITHOUT ADDITIONAL COST TO OWNER. CONTRACTOR AND HIS SUBCONTRACTORS SHALL, AT THEIR EXPENSE, REPLACE OR REPAIR, AS
DIRECTED, DAMAGED PORTIONS OF THEIR WORK OR COMPONENT PARTS.
20. TOXIC SUBSTANCES REMOVAL: PRIOR TO ANY WORK BEING PERFORMED, WHENEVER THERE ARE EXISTING STRUCTURES TO BE REMOVED OR ALTERED, CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION AND REMOVAL OF ANY TOXIC MATERIALS OR SUBSTANCES AS
REQUIRED BY THE STATE OF CALIFORNIA INCLUDING BUT NOT LIMITED TO ASBESTOS, LEAD PAINTS, MOLD, ETC. REMOVAL AND DISPOSAL SHALL FOLLOW STATE MANDATED METHODS, PROCEDURES, DOCUMENTATION AND APPLICATION REQUIREMENTS.
21. NO CHANGES ARE TO BE MADE ON THESE PLANS WITHOUT THE KNOWLEDGE OR CONSENT OF THE ARCHITECT/ ENGINEER WHOSE SIGNATURE APPEARS HERON.
22. NO FRAMING OF ANY TYPE TO BE CONCEALED PRIOR TO INSPECTION BY GOVERNING AGENCIES.
23. REFERENCES TO ANY DETAIL OR DRAWINGS IS FOR CONVENIENCE ONLY AND DOES NOT LIMIT THE APPLICATION OF SUCH DETAIL OR DRAWINGS.
24. USE 2X6 MINIMUM STUDS FOR PLUMBING WALLS
25. MAXIMUM FLOW RATE STANDARDS SET BY THE CURRENT CALIFORNIA GREEN CODE - G.C. TO VERIFY PRIOR TO PURCHASE AND INSTALL. OF ANY FIXTURES.
26. EXTERIOR DECKS, BALCONIES, AND STAIRWAYS SEALED UNDERNEATH SHALL BE WATERPROOFED- ARCH. TO APPV. METHOD OF WATERPROOFING - G.C. TO SUBMIT SPECIFICATIONS.
27. SPECIAL INSPECTION IS REQUIRED FOR THE FOLLOWING:
* FOUNDATION INSPECTION BY SOILS ENGINEER PRIOR TO CONCRETE POUR AND:
* PER SOILS REPORT: OVER EXCAVATION, RECOMPACTION, FOOTING DEPTH, UTILITY TRENCH BACKFILL
* RETAINING WALL BACKFILL, PRE SATURATION OF SLAB AREAS, EXTERIOR FLAT WORK AREAS.
* ALL TO BE ADDRESSED IN A REPORT PRESENTED TO BUILDING DEPT. PRIOR TO FINAL
* ALL FIELD WELDING OF STRUCTURAL STEEL
* INSTALLATION OF ALL HIGH STRENGTH BOLTS
* CERTIFICATION OF WELD, & BOLTING TO BE GIVEN TO BUILDING DEPARTMENT PRIOR TO FRAMING INSPECTION.
28. MAX. TEMP. OF 120° TO BE APPROVED BY THE USE OF PRESSURE BALANCE OR THERMOSTATIC MIXING VALVES TYP. @ SHOWERS & TUBS.
29. MAINTENANCE INFORMATION: THE BUILDER SHALL PROVIDE TO THE BUILDING OWNER AT OCCUPANCY MAINTENANCE INFORMATION FOR ALL FEATURES, MATERIALS, COMPONENTS, AND MANUFACTURED INFORMATION FOR ALL FEATURES, MATERIALS, AND COMPONENTS AND
MANUFACTURED DEVICES THAT REQUIRE ROUTINE MAINTENANCE FOR EFFICIENT OPERATION. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY STATED AND INCORPORATED ON A READILY ACCESSIBLE LABEL. THE LABEL MAY BE LIMITED TO IDENTIFYING, BY TITLE
AND/OR PUBLICATION NUMBER, THE OPERATION AND MAINTENANCE MANUAL FOR THAT PARTICULAR MODEL AND TYPE OF FEATURE, MATERIAL, COMPONENT, OR MANUFACTURED DEVICE.
30. AFTER INSTALLING WALL, CEILING, OR FLOOR INSULATION, THE INSTALLER SHALL MAKE AVAILABLE TO THE ENFORCEMENT AGENCY OR POST IN A CONSPICUOUS LOCATION IN THE BUILDING A CERTIFICATE SIGNED BY THE INSTALLER STATING THAT THE INSTALLATION IS
CONSISTENT WITH THE PLANS AND SPECIFICATIONS FOR WHICH THE BUILDING PERMIT WAS ISSUED. THE CERTIFICATE SHALL ALSO STATE THE MANUFACTURER'S NAME AND MATERIAL IDENTIFICATION, THE INSTALLED R-VALUE, AND (IN APPLICATIONS OF LOOSE FILL INSULATION) THE
MINIMUM INSTALLED WEIGHT PER SQUARE FOOT CONSISTENT WITH THE MANUFACTURER'S LABELED INSTALLED DESIGN DENSITY FOR THE DESIRED R-VALUE.
31. ON PROJECTS WITH EXCAVATIONS THAT WILL BE LOWER THAN ADJOINING PROPERTIES, 30 DAY NOTICE IS LEGALLY REQUIRED BY THE OWNERS & CONTRACTORS TO THE ADJOINING PROPERTY OWNERS OUTSIDE THE SETBACK AREA.
32. DISTANCE FROM THE FACE OF FOUNDATION TO PROPERTY LINE TO BE ZONING SETBACK PLUS WALL FINISH THICKNESS.
33. ROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR FIXTURES SHALL BE PROVIDED WITH ON EXHAUST FAN WITH A MINIMUM CAPACITY OF 50 CFM. DUCTLESS FANS ARE UNACCEPTABLE. CBC 1203.4.3.2.1, CMC T-4-4
35. CLEARANCE FOR WATER CLOSET TO BE A MINIMUM OF 24-INCHES IN FRONT AND 15-INCHES FROM ITS CENTER TO ANY SIDE WALL OR OBSTRUCTION. CPC 407.5
36. THE NET AREA OF THE SHOWER ENCLOSURE SHALL BE 1,024 SQ. INCHES (7.1 SQ. FT.) OR MORE IN THE CLEAR FLOOR AREA, AND SHALL ALSO BE CAPABLE OF ENCOMPASSING A 30-INCH DIAMETER CIRCLE. CPC 411.7
37. WALL COVERINGS OR SHOWERS OR TUBS WITH SHOWERS SHALL BE OF CEMENT PLASTER, TILE, OR APPROVED EQUAL, TO A HEIGHT OF NOT LESS THAN 70-INCHES ABOVE DRAIN INLET. PROVIDE CEMENT BOARD OR CEMENT PLASTER BACKING FOR TILE. CBC 1210.3
38. MIN. 5/8" TYPE 'X' MOISTURE RESISTANT GYPSUM WALL BOARD IN ALL BATHROOMS AND KITCHENS
39. EXTERIOR LATH AND PLASTER: PROVIDE TWO LAYERS OF GRADE D PAPER OVER ALL WOOD BASE SHEATHING. CBC 2510.6
40. THE WATER HEATER BURNER TO BE AT LEAST 18-INCHES ABOVE THE GARAGE FLOOR, IF LOCATED IN A GARAGE. CPC 508.14
41. PROVIDE A 3-INCH DIAMETER BY 3-FOOT TALL STEEL PIPE EMBEDDED IN CONCRETE SLAB FOR PROTECTION OF WATER HEATERS IN GARAGE. CPC 508.14
42. WATER HEATERS TO BE STRAPPED AT TOP AND BOTTOM WITH 1-1/2" X 16 GAUGE STRAP WITH 3/8" DIA. X 3" LAG BOLT EACH IND. CPC 508.2
43. DRYER: THE CLOTHES DRYERS VENT SHALL NOT EXCEED 14-FEET IN OVERALL LENGTH. CMC 504.3.2 DRYER VENT TERMINATION MUST BE 3 FT. CLEAR FROM OPENINGS INTO THE BUILDING (DOORS AND OPERABLE WINDOWS). CMC 504.5 PROVIDE A MIN. 100 SQ.IN. OPENING IN
THE DRYER DOOR. CMC. 504.3.2
44. SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS (R314.3):
A. IN EACH SLEEPING ROOM.
B. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS
C. ON EVERY LEVEL OF DWELLING, INCLUDING BASEMENTS AND HABITABLE ATTICS.
D. SMOKE ALARMS SHALL BE HARDWIRED WITH BATTERY BACK-UP AND INTERCONNECTED UNLESS EXEMPTED IN ACCORDANCE WITH SECTIONS R314.4 & R314.5
45. CARBON MONOXIDE ALARMS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS (R315.3):
A. OUTSIDE OF EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOM(S)
B. ON EVERY LEVEL OF THE DWELLING UNIT INCLUDING BASEMENTS.
C. CARBON MONOXIDE ALARMS SHALL BE HARDWIRED WITH BATTERY BACK-UP AND INTERCONNECTED UNLESS EXEMPTED IN ACCORDANCE WITH SECTIONS R314.4 & R314.5
46. ALL RECEPTACLE OUTLETS IN BATHROOMS, ABOVE KITCHEN COUNTERTOP, CRAWL SPACES, GARAGE, ROOFTOPS, OUTDOOR OUTLETS, WITHIN 6-FEET OF WET BAR SINK/LAUNDRY SINK TO BE PROTECTED BY GROUND FAULT CIRCUIT INTERRUPTER (GFCI) CEC 210.8
47. ALL 120V SINGLE PHASE, 15 AND 20 AMP OUTLETS (RECEPTACLES, LIGHTING, SMOKE DETECTORS, ETC.) TO BE PROTECTED BY COMBINATION TYPE ARC-FAULT CIRCUIT INTERRUPTER (AFCI) CEC 210.12
48. ELECTRICAL SERVICE TO BE UNDERGROUND FOR NEW CONSTRUCTION OR ADDITIONS >50%. NBMC 12.32.015
49. INSPECTOR TO REVIEW AND APPROVE UNDERGROUND ELEC. SERVICE PRIOR TO CONCRETE PLACEMENT.
50. UTILITY COMPANY APPROVAL IS REQUIRED FOR METER LOCATION PRIOR TO INSTALLATION.
51. FACTORY-BUILT FIREPLACES, CHIMNEYS, AND ALL OTHER COMPONENTS SHALL BE LISTED AND LABELED AND SHALL BE INSTALLED IN ACCORDANCE WITH THE CONDITIONS OF THE LISTING
52. FIREPLACE: DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT THE TERMINATION OF FACTORY-BUILT CHIMNEY SYSTEMS AND ARE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS R1005.4NG. CMC (802.5.2.4) PROVIDE A PERMANENTLY
ANCHORED GASEOUS FUEL BURNING PAN TO THE FIREBOX IN A SOLD FUEL BURNING FIREPLACE. SOLID FUEL BURNING FIREPLACE MUST COMPLY WITH THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES." GAS APPLIANCE FIREPLACE MUST COMPLY WITH THE CALGREEN
CODE REQUIREMENTS."
53. ALL DOORS FROM THE HOUSE INTO THE POOL AREA SHALL BE EQUIPPED WITH AN APPROVED ALARM OR AN APPROVED ALTERNATE DROWNING PREVENTION SAFETY FEATURE. CBC 3109.4.4.2
54. GENERAL CONTRACTOR, CONTRACTORS, SUB-CONTRACTORS AND BUILDERS TO COORDINATE ALL ENGINEERING AND MECHANICAL DRAWINGS WITH ARCHITECTURAL DRAWINGS BEFORE PROCEEDING WITH WORK. IF DISCREPANCIES ARE APPARENTLY OBSERVED OR
INFORMATION APPARENTLY IS THOUGHT TO BE MISSING, NOTIFY ARCHITECT WITHIN 24 HOURS WITH SKETCH, DRAWING, PDF, PHOTOCOPIES WITH LEGIBLE HANDWRITTEN NOTES AND/OR WRITING (FAX, EMAIL OR CORRESPONDENCE). IF CONFLICT WITH EXISTING CONDITIONS,
PROVIDE DOCUMENTATION (PHOTOS, SKETCHES, DWGS) OF EXISTING CONDITIONS AND SUGGEST PROPOSAL(S) FOR SOLUTION (SKETCH, DRAWING, AND/OR WRITING). IN CASE OF ANY DISCREPANCIES, THE ARCHITECT IS THE SOLE INTERPRETER OF THE CONTRACT DOCUMENTS.
55. ISSUANCE OF A BUILDING PERMIT DOES NOT RELIEVE APPLICANTS OF THE LEGAL REQUIREMENTS TO OBSERVE COVENANTS, CONDITIONS AND RESTRICTIONS WHICH MAY BE RECORDED AGAINST THE PROPERTY OR TO OBTAIN PLANS. YOU SHOULD CONTACT YOUR COMMUNITY
ASSOCIATIONS PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION AUTHORIZED BY THIS PERMIT.
56. LAND. WALLS LOCATED IN FRONT AND BACK OF PROPERTY SHALL NOT EXCEED 42" HT. REFER. LAND. DWGS FOR LOC'T.
57. LAND. WALLS LOCATED BTW. NEIGHBORS SHALL BE SHARED ON PROP. LINE. REFER. LAND. DWGS AND SEE ATTACHED DOCUMENT FOR "AGREEMENT TO BUILD A FENCE OR WALL CENTERED OVER THE PROPERTY WALL."
58. ALL INTERIOR AND EXTERIOR JOINTS BETWEEN DIFFERENT MATERIALS OR FINISHES SHALL RECEIVE A BEAD OF CAULKING OR SEALANT TO FORM A REVEAL TO MATCH COLOR OF ADJACENT SURFACE. COORDINATE COLORS WITH ARCHITECT.
59. CONTRACTOR SHALL NOTIFY ARCHITECT FOR CLARIFICATION PRIOR TO BIDDING OF ANY DISCREPANCIES BETWEEN ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS. BID SHALL BE BASED ON THE MOST STRINGENT REQUIREMENT.
60. CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT OF ANY UNEXPECTED OR UNKNOWN FIELD CONDITIONS, ERRORS, OMISSIONS, OR DISCREPANCIES IN THE DRAWINGS, PROJECT MANUAL, OR CONTRACT DOCUMENTS PRIOR TO PROCEEDING WITH THE WORK OR SHOP
FABRICATIONS.
61. CONTRACTOR SHALL PREPARE AND MAINTAIN ALL CONSTRUCTION, AND SURROUNDING AREAS, FREE OF DEBRIS OR HAZARDOUS MATERIALS AT ALL TIMES. CONTRACTOR SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT DUST FROM RISING.
62. CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR AND/OR THE REPLACEMENT OF ANY ITEMS DAMAGED DURING CONSTRUCTION OR CLEAN-UP. ANY DAMAGE TO EXISTING STRUCTURES DURING THE CONSTRUCTION OR THE NEW WORK SHALL BE REPAIRED TO EQUIVALENT
OR BETTER THAN ORIGINAL CONDITION AT CONTRACTOR'S EXPENSE.
63. CONSTRUCTION PERSONNEL SHALL BE CONFINED TO THE LIMITS OF THE CONSTRUCTION AREA. ALL OSHA REGULATIONS FOR CONSTRUCTION AREAS SHALL BE STRICTLY FOLLOWED. CONTRACTOR SHALL PROVIDE PROPER SAFEGUARDS DURING ALL PHASES OF
CONSTRUCTION.
64. CONTRACTOR TO REMOVE, RELOCATE OR RE-ROUTE, AS NECESSARY, ELECTRICAL, TELEPHONE, WATER, SEWER, GAS OR ANY OTHER UTILITY LINES ENCOUNTERED AND SHALL COORDINATE THIS WORK WILL ALL LOCAL UTILITY COMPANIES.
65. CONTRACTOR SHALL PROVIDE TEMPORARY WEATHER PROTECTION FOR PORTIONS OF THE WORK THAT BECOME EXPOSED TO WEATHER AND SHALL BE RESPONSIBLE FOR DAMAGE CAUSED BY INSUFFICIENT PROTECTION.
66. CONTRACTOR TO OBTAIN WRITTEN APPROVAL FROM OWNER AND ARCHITECT PRIOR TO ANY CHANGES OR DEVIATION FROM CONTRACT DOCUMENTS.
67. CONTRACTOR SHALL SUBMIT IN WRITING ALL PROPOSALS FOR ADDITIONAL WORK TO THE OWNER FOR REVIEW AND APPROVAL. NO WORK IS TO PROCEED UNTIL AN AUTHORIZATION TO PROCEED; SIGNED BY THE ARCHITECT & OWNER'S REPRESENTATIVE IS RETURNED TO THE
GENERAL CONTRACTOR.
68. CONTRACTOR SHALL BE AWARE THAT SPECIFIC FIRE-RATED SEPARATION WITHIN THE BUILDING'S CONSTRUCTION IS REQUIRED BY CODE. THE USE OF SPECIFIC MATERIALS AND COMBINATION OF MATERIALS WITHIN FIRE RATED ASSEMBLIES, AS CALLED FOR ON THE DRAWINGS
AND SPECIFICATIONS, ARE FOR THE PURPOSE OF ACHIEVING THOSE REQUIRED FIRE SEPARATIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THAT ANY CHANGE IN MATERIAL THAT IS REQUESTED BY OR MADE BY THE CONTRACTOR AND/OR ITS SUBCONTRACTORS,
FROM THOSE MATERIALS DRAWN OR SPECIFIED, DOES NOT IN ANY WAY AFFECT OR LESSEN THE REQUIRED CONSTRUCTION ASSEMBLY. SPECIFIC SEQUENCES OR METHODS OF ACHIEVING FIRE RATED ASSEMBLIES REQUIRED BY A "U.L. NO." LISTING SHALL BE FOLLOWED WITHOUT
DEVIATION, UNLESS OTHERWISE NOTED OR DETAILED.
69. CONTRACTOR TO FURNISH AND INSTALL ALL BLOCKING REQUIRED FOR WALL MOUNTED OR BRACED FIXTURES, MILLWORK, SHELVES, TOILET FIXTURES, AND ACCESSORIES OR 'BY OTHER' ITEMS DESCRIBED IN INTERIOR DESIGN AND ARCHITECTURAL DRAWINGS. BLOCKING SHALL
BE CONSTRUCTED TO SUPPORT THE IMPOSED LOAD.
70. ALL MANUFACTURED ARTICLES, MATERIALS AND EQUIPMENT SHALL BE SUPPLIED, INSTALLED, CONNECTED, ERECTED, USED, CLEANED AND CONDITIONED AS DIRECTED BY THE MANUFACTURERS.
71. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY/COORDINATE UTILITY REQUIREMENTS FOR ALL OWNER/VENDOR FURNISHED EQUIPMENT, FIXTURES OR APPLIANCES.
72. CONTRACTOR SHALL PROVIDE ALL NECESSARY FASTENERS, SUPPORTS, SHIMMING, FLASH PATCHING, ETC. FOR THE PROPER INSTALLATION OF SUCH ITEMS AS DIRECTED BY THE MANUFACTURERS.
73. UPON COMPLETION OF THE PROJECT, THE CONTRACTOR SHALL GIVE TO THE OWNER A COMPLETE SET OF AS-BUILT CIVIL, LANDSCAPE, ARCHITECTURAL, MECHANICAL, PLUMBING ELECTRICAL AND FIRE PROTECTION DRAWINGS ALONG WITH THE WRITTEN GUARANTIES,
OPERATION AND MAINTENANCE MANUALS OF ALL EQUIPMENT AND FINISHES INSTALLED. THE CONTRACTOR SHALL MAINTAIN A CURRENT SET OF AS-BUILT DRAWINGS AND SPECIFICATIONS. INFORMATION SHALL BE RECORDED BY CONTRACTOR AS CONSTRUCTION PROGRESSES
AND REVIEWED FOR COMPLETENESS AT EACH REQUISITION REQUEST.
74. CONTRACTOR IS RESPONSIBLE TO THOROUGHLY VACUUM CLEAN ALL CARPETED AREAS, CLEAN ALL FLOORING, MILLWORK, LIGHT FIXTURES, GLASS, ETC. AND UNCOVER AND VACUUM OUT ALL MECHANICAL UNITES AFTER THE WORK IS COMPLETED AND MAINTAIN CLEAN
CONDITIONS THROUGH THE TENANT'S MOVE-IN.
PA2021-013
BRANDON ARCHITECTS
DATE
T-1.2
PROJECT CONTACT
JEFF VAN VOORHIS, AIA
PROJECT NAME
PROJECT ADDRESS
908 W. OCEANFRONT
NEWPORT BEACH, CA 92661
OWNER INFORMATION
908 NB PROPERTY MANAGEMENT LLC
3717 EUCLID AVE.
DALLAS, TX
PROJECT STATUS
CDP
PLAN CHECK NO.
TBD
REVISIONS
NO.
DATE
1/27/2021 HARVEY RESIDENCESUPPLEMENTAL
DOCUMENTS &
NOTES
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
REVISIONS
These documents are the property of BRANDON
ARCHITECTS INC., and are not to be duplicated,
altered or utilized in any ay by any other party
without the expressed authorization of
BRANDON ARCHITECTS. Any unauthorized
duplication or alteration of these documents by
any party is a violation of BRANDON
ARCHITECTS expressed common law copyright
and other property rights thereto, and is subject
to full civil liabilities and penalties. These plans
are also not to be assigned to any third party
without obtaining written authorization and
expressed permission by BRANDON
ARCHITECTS, who shall then be held harmless
and absolved of any liability regarding any use
of these documents by such third party whether
depicted or implied hereon.1 CAL GREEN - RESIDENTIAL MINIMUM REQUIREMENTS
2 RESIDENTIAL CONSTRUCTION MINIMUM REQUIREMENTS
PA2021-013
N18°27'05"E 93.37'N71°37'07"W 40.02'N18°28'51"E 89.07'N77°46'14"W 40.21'LOT 3
TRACT NO. 234
M.M. 13/36-37
LOT 2
LOT 4
OCEANFRONT W.CLW. OCEANFRONTBASIS OF BEARINGS
THE BASIS OF BEARINGS SHOWN HEREON ARE BASED ON THE BEARING
BETWEEN ORANGE COUNTY SURVEYOR'S HORIZONTAL CONTROL STATIONS
G.P.S. NO. 6723 AND G.P.S. NO. 6183R1, BEING N74°28'54"W PER RECORDS ON
FILE IN THE OFFICE OF THE ORANGE COUNTY SURVEYOR.
VICINITY MAP
BENCHMARK INFORMATION
908 W. OCEANFRONTNEWPORT BEACH, CA 92661(APN: 047-281-15)TOPOGRAPHIC MAP1 1
TITLE REPORT/EASEMENT NOTES
908 W. OCEANFRONT
NEWPORT BEACH, CA 92661
(APN: 047-281-15)
NO TITLE REPORT PROVIDED
LEGAL DESCRIPTION
REAL PROPERTY SITUATED IN THE CITY OF NEWPORT BEACH,
COUNTY OF ORANGE, STATE OF CALIFORNIA AND IS
DESCRIBED AS FOLLOWS:
LOT 3 IN BLOCK 9 OF TRACT NO. 234, IN THE CITY OF NEWPORT
BEACH, COUNTY OF ORANGE, STATE OF CALIFORNIA AS PER
MAP RECORDED IN BOOK 13, PAGES 36-37, OF
MISCELLANEOUS MAPS IN THE OFFICE OF THE COUNTY
RECORDER OF SAID COUNTY.
LC
EXISTING ELEVATION
LEGEND
( )
AC ASPHALT PAVEMENT
FOUND MONUMENT
SEARCHED, FOUND NOTHING; SET
NOTHING
FS
FL
FINISHED SURFACE
FLOWLINE
FFG FINISHED FLOOR GARAGE
GRASS SURFACE
T.B.M.TEMPORARY BENCHMARK
SET ON A WATER METER (WM)
ELEVATION = 10.83 FEET
HUNTINGTON BEACH, CALIFORNIA 92646PHONE:(714)488-5006 FAX:(714)333-4440 APEXLSINC@GMAIL.COMPAUL D. CRAFT, P.L.S. 8516 DATE
NOTE: SECTION 8770.6 OF THE CALIFORNIA BUSINESS AND PROFESSIONS CODE
STATES THAT THE USE OF THE WORD CERTIFY OR CERTIFICATION BY A
LICENSED LAND SURVEYOR IN THE PRACTICE OF LAND SURVEYING OR THE
PREPARATION OF MAPS, PLATS, REPORTS, DESCRIPTIONS OR OTHER SURVEYING
DOCUMENTS ONLY CONSTITUTES AN EXPRESSION OF PROFESSIONAL OPINION
REGARDING THOSE FACTS OR FINDINGS WHICH ARE THE SUBJECT OF THE
CERTIFICATION AND DOES NOT CONSTITUTE A WARRANTY OR GUARANTEE,
EITHER EXPRESSED OR IMPLIED.
LICENSE RENEWAL DATE 12/31/20
S
TATE OF CAL I F O R NI APAULD O M INICK
CRAFTExp. 12/31/20
No. 8516PROFESSIONALLAND
S
URVEYORFF FINISHED FLOOR
WATER METERWM
EG EDGE OF GUTTER
GAS METERGM
CENTERLINE
TW TOP OF WALL
GRAPHIC SCALE
SURVEYOR OR ENGINEER SHALL PERMANENTLY MONUMENT PROPERTY
CORNERS OR OFFSETS BEFORE STARTING GRADING.
PLEASE CALL PAUL CRAFT @ 714-488-5006 TO SCHEDULE.
SURVEYOR'S NOTES
BLOCK WALL
NG NATURAL GROUND
BENCHMARK NO: IE-122-14
DESCRIBED BY OCS 2014 - FOUND 4” OCS
ALUMINUM BENCHMARK DISC STAMPED “1E-122-14”
ON THE SOUTHWEST CORNER OF A 4’ CATCH
BASIN. MONUMENT IS LOCATED ALONG THE SOUTH
SIDE OF W. BALBOA BLVD., 133’ WEST OF THE C/L
OF 7TH ST. @ ADDRESS 709. MONUMENT IS LEVEL
WITH THE SIDEWALK.
ELEVATION: 9.179 FEET (NAVD88), YEAR LEVELED 2015
ACU AIR CONDITION UNIT
CATV CABLE TV BOX
CONCRETE SURFACE
TWS TOP OF WALL STEP
GUARD POSTGP
TS TOP OF STEP
SCO SEWER CLEAN OUT
BS BOTTOM OF STEP
PA2021-013
PA2021-013
PA2021-013
BRANDON ARCHITECTS
DATE
A-0.0
PROJECT CONTACT
JEFF VAN VOORHIS, AIA
PROJECT NAME
PROJECT ADDRESS
908 W. OCEANFRONT
NEWPORT BEACH, CA 92661
OWNER INFORMATION
908 NB PROPERTY MANAGEMENT LLC
3717 EUCLID AVE.
DALLAS, TX
PROJECT STATUS
CDP
PLAN CHECK NO.
TBD
REVISIONS
NO.
DATE
1/27/2021 HARVEY RESIDENCEARCHITECTURAL
SITE PLAN
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
REVISIONS
These documents are the property of BRANDON
ARCHITECTS INC., and are not to be duplicated,
altered or utilized in any ay by any other party
without the expressed authorization of
BRANDON ARCHITECTS. Any unauthorized
duplication or alteration of these documents by
any party is a violation of BRANDON
ARCHITECTS expressed common law copyright
and other property rights thereto, and is subject
to full civil liabilities and penalties. These plans
are also not to be assigned to any third party
without obtaining written authorization and
expressed permission by BRANDON
ARCHITECTS, who shall then be held harmless
and absolved of any liability regarding any use
of these documents by such third party whether
depicted or implied hereon.
EXISTING
BUILDING
EXISTING
BUILDING
EXISTING
BUILDING
GM
SCO
N18°27'05"E 93.37'N71°37'07"W 40.02'N18°28'51"E 89.07'N77°46'14"W 40.21'(11.09)
FS
(10.74)
FS
(11.26)
FFG
(29.96)
RIDGE (10.94)
FS
(12.07)
FS
(12.15)FS
(11.71)
FS
(11.68)
FS
(39.38)
CHIMNEY TOP
(12.02)
FS(13.13)
TS
(12.22)
FF
(11.47)
FS
(12.26)
FF
(12.14)
FS
(12.28)
FF
(12.21)
TS
(11.29)
FS
(11.10)
FS
(10.92)
FS
(10.14)
FL
(10.14)
FL
(10.19)
FL
(10.20)
FL
(10.23)
FL
(10.23)
FL
(10.82)
FS(10.89)
FS
(11.25)FS
GATE
(10.82)
FS
(11.30)
FS
(11.16)
FS(11.25)
FS
(11.36)
FS
(11.48)
FS(11.51)
FS
(12.10)FS
(33.66)
CHIMNEY TOP
(31.08)
RIDGE
(38.85)
CHIMNEY TOP
(13.03)
TS
(11.60)
FS
(11.62)
FS
(11.59)
FS
(11.62)
FS
(11.64)
FS
(11.18)
NG~SAND
(11.19)
NG~SAND
(10.83)
WM
SCO SCO
GATE
(11.83)
FS
(14.97)TW
(11.88)FS
(14.08)TW
(11.89)FS
(14.13)
TW
(14.03)TW
(11.85)FS
(14.81)TW
(11.85)FS
GATE
(11.25)
FS
(12.11)
FS
(12.06)
FS
(12.85)
FS
(12.78)
FS
(11.85)
FS
(11.79)
FS
(11.66)
FS GP16.49TWS
14.92TW
12.72
TS
12.72
TS11.68FS
11.72
FS
11.83
FS
11.94
FS12.52
FS (17.18)TWS
(14.85)TW
LOT 3
TRACT NO. 234
M.M. 13/36-37
LOT 2
LOT 4
OCEANFRONT W.CLW. OCEANFRONTSAND
SAND
SAND
PROPERTYLINE
PROPERTY
LINE
PROPERTYLINE
PROPERTY
LINE
FOUND LEADHOLE
FOUND TAG IN
EPOXY, LS4653
FOUND LEAD
& TAG, LS4653
(12.01)TS
(11.69)BS
(12.13)TS
(11.80)BS
(12.09)
FS
(12.01)
FS
(12.08)
FS
(12.11)
FS
(12.14)
FS
(12.20)
FS
(12.19)
FS
(12.23)TS
(11.77)BS
A SITE PLAN NOTES
B KEYNOTES
B ANNOTATION LEGEND
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE NEAREST
1/8" - CONTACT ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
STAIRWAY NOTE:
ALL STAIRWAYS SHALL HAVE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT CANDLE PER CRC R303.7
ROUGH FRAMING:
ALL EXTERIOR WALLS TO BE FRAMED WITH 2 X 6 STUDS
SECOND AND THIRD FLOOR PLYWOOD TO BE 1-1/8"
ENTIRE EXTERIOR TO BE SHEATHED WITH 1/2" PLYWOOD
GENERAL NOTE:
SEE SHEET A-3.0 FOR ROOF PLAN INFORMATION NOT SHOWN ON THIS SHEET (INCLUDING EAVE DETAILS AND PROJECTION DISTANCES).
C.N.B. NOTES:
1. ISSUANCE OF A BUILDING PERMIT BY THE CITY OF NEWPORT BEACH DOES NOT RELIEVE APPLICANTS OF THE LEGAL REQUIREMENTS
TO OBSERVE COVENANTS, CONDITIONS AND RESTRICTIONS WHICH MAY BE RECORDED AGAINST THE PROPERTY OR TO OBTAIN PLANS
YOU SHOULD CONTACT YOUR COMMUNITY ASSOCIATIONS PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION AUTHORIZED BY THIS
PERMIT.
2. PRIOR TO PERFORMING ANY WORK IN THE CITY RIGHT-OF-WAY AN ENCROACHMENT PERMIT MUST BE OBTAINED FROM THE PUBLIC
WORKS DEPARTMENT.
3. A CAL-OSHA PERMIT IS REQUIRED FOR EXCAVATIONS DEEPER THAN 5' AND FOR SHORING AND UNDERPINNING.
LANDSCAPE NOTES:
1. ENCROACHMENT PERMIT REQ'D. FOR ANY WORK PROPOSED IN THE PUBLIC R.O.W.
2. IF APPLICABLE, REF. PRELIMINARY LANDSCAPE PLANS, FOR ALL HARDSCAPE & PLANTING AREAS WITH RESPECTIVE HEIGHTS AND
MATERIALS.
*HERS VERIFICATION REQUIRED- REFERENCE T-24.1
DN.
DN.
DN.3'-0"S.Y.S.B.3'-0"S.Y.S.B.8'-0"
F.Y.S.B.3'-0"F.O.F.3'-1"F.O.F.3'-10"F.O.F.3'-0"F.O.F.3'-1"F.O.F.3'-0"F.O.F.4'-0"F.O.F.3'-10 7/8"2'-7 1/2"2'-10 5/8"5'-0 1/8"36" MIN.CLR.23'-6 3/4"CLR.30'-9 3/8"20'-0"CLR.17'-3 3/8"CLR.11.80' F.F.REF. CIVIL FOR TOP OF SLAB
11.80' F.F.REF. CIVIL FOR TOP OF SLAB15.51' T.W.12.01' F.S.15.51' T.W.12.20' F.S.15.51' T.G.14.01' T.W.12.14' F.S.15.51' T.W.12.11' F.S.15.51' T.W.12.23' F.S.17.25' T.W.11.83' F.S.17.25' T.W.11.25' T.S.15.51' T.G.14.01' T.W.12.11' F.S.SLOPE PER CIVIL
SLOPE PER CIVIL
01.01
01.02
01.04
01.04
01.01
02.01
02.01
01.01
02.37
02.27
02.03
02.31
02.39
32.01
32.01
32.0132.26
32.26
03.12
32.21
02.17 02.17
32.18
02.01
32.01
26.02
11.01
32.13
11.33
APN: 047 281 15
LOT 3, BLOCK 9
TRM_00234
MM_013_36-38OCEANFRONT W.SAND
W. OCEANFRONTADJACENT PROPERTY
(NOT A PART)
ADJACENT PROPERTY
(NOT A PART)
N18°27'05"E 93.37'
N18°28'51"E 89.07'N77°46'14"W 40.21'N71°37'07"W 40.02'PATIO
(REF. CIVIL & LND. DWGS.)
3-CAR GARAGE
SAND ROOM
ELEV.
PWDR.
GREATROOM
DINING
KITCHEN
LOUNGE ENTRY STAIRS
PANTRY
UP
DN.
DN.
PT.2
11.09' FS
PT.4
11.83' FS
PT.1
11.60' FS
PT.3
10.94' FS
PT. 1 11.60'
PT. 2 11.09'
PT. 3 10.94'
PT. 4 11.83'
45.46 / 4 = 11.36'
PROJECT NORTHTRUE NORTH
ROOM NAME
UP
20R x 7 1/2"NN
15'-6"
1
A-4.0
N90° 00' 00"E 78.25'
1
01.13
1i
ELEVATION/SECTION INDICATOR
WINDOW TAG
DOOR TAG
ROOM TAG
PROPERTY LINE TAG
STAIR TAG (NO. OF RISER & HEIGHT)
KEYNOTE TAG
SPOT ELEVATION
KEYNOTES
GENERAL NOTES
01.01 PROPERTY LINE
01.02 FRONT YARD SETBACK
01.04 SIDE YARD SETBACK
EXISTING CONDITIONS
02.01 FOOTPRINT OF EXISTING STRUCTURE
TO BE REMOVED
02.03 CENTERLINE/FLOWLINE OF ALLEY
02.17 (E.) PROPERTY LINE WALL
PROTECT IN PLACE
02.27 (E.) GAS METER LOCATION
REF. SURVEY & CIVIL DWGS.
02.31 (E.) SEWER C.O. LOCATION
REF. SURVEY & CIVIL DWGS.
02.37 (E.) WATER METER LOCATION
REF. SURVEY & CIVIL DWGS.
02.39 (E.) GUARD POST
TO BE REMOVED - REF. SURVEY & CIVIL DWGS.
CONCRETE
03.12 DEPRESS SLAB
FOR PEDESTAL FLOOR SYSTEM. REF. CIVIL AND SLAB EDGE PLAN
EQUIPMENT
11.01 FIREPIT
PROVIDE GAS STUB-OUT, REF. LAND. DWGS., G.C. TO VERIFY LOC'N W/. OWNER
11.33 (N.) BBQ.
PROVIDE GAS STUB-OUT AND ELECTRICITY AS REQ'D., REF. LAND. DWGS., G.C. TO VERIFY LOC'N W/. OWNER
ELECTRICAL
26.02 RECESSED MAIN SERVICE PANEL
400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION)
EXTERIOR IMPROVEMENTS
32.01 (N.) HARDSCAPE
COLORED & SCORED CONCRETE OR STONE PAVERS (AS SELECTED), REF. LAND. DWGS.
32.13 (N.) 42" TALL GATE
REF. LANDS. DWGS.
32.18 (N.) LANDSCAPE WALL
CMU PILASTER W/. STUCCO FINISH WITH 18" GLASS TOP, MAX. HT. 42" (REF. CIVIL DWGS.)
32.21 (N.) PROPERTY LINE WALL
PLASTER FINISH TO MATCH (MAX. 6' ABV. N.G.)
32.26 (N.) CONCRETE STEPS ON GRADE
REF. CIVIL DWGS.
SCALE: 3/16" = 1'-0"1ARCHITECTURAL SITE PLAN
SCALE: 1/8" = 1'-0"2GRADE PLANE EXHIBIT
PA2021-013
BRANDON ARCHITECTS
DATE
A-0.2
PROJECT CONTACT
JEFF VAN VOORHIS, AIA
PROJECT NAME
PROJECT ADDRESS
908 W. OCEANFRONT
NEWPORT BEACH, CA 92661
OWNER INFORMATION
908 NB PROPERTY MANAGEMENT LLC
3717 EUCLID AVE.
DALLAS, TX
PROJECT STATUS
CDP
PLAN CHECK NO.
TBD
REVISIONS
NO.
DATE
1/27/2021 HARVEY RESIDENCEAREA PLANS
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
REVISIONS
These documents are the property of BRANDON
ARCHITECTS INC., and are not to be duplicated,
altered or utilized in any ay by any other party
without the expressed authorization of
BRANDON ARCHITECTS. Any unauthorized
duplication or alteration of these documents by
any party is a violation of BRANDON
ARCHITECTS expressed common law copyright
and other property rights thereto, and is subject
to full civil liabilities and penalties. These plans
are also not to be assigned to any third party
without obtaining written authorization and
expressed permission by BRANDON
ARCHITECTS, who shall then be held harmless
and absolved of any liability regarding any use
of these documents by such third party whether
depicted or implied hereon.
A GENERAL NOTES
B KEYNOTES
NOTE:
GENERAL CONTRACTOR TO PROVIDE SHOP DRAWINGS CONSISTENT WITH THE CONSTRUCTION DOCUMENTS. GENERAL
CONTRACTOR TO REVIEW AND APPROVE ALL FINAL SHOP DRAWINGS PRIOR TO FABRICATION & POURING.
ARCHITECT & STRUCTURAL ENGINEER TO REVIEW SHOP DWGS. FOR DESIGN CONFORMITY TO THE CONSTRUCTION DOCUMENTS
PRIOR TO FABRICATION & POURING.
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE NEAREST
1/8" - CONTACT ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
GENERAL NOTES TO BE ADDED TO SLAB EDGE PLAN - DELETE IF
NOT NEEDED
SLAB DEPRESSION FOR F.P. VERIFY W/. G.C. & MFGR.
SLAB DEPRESSION FOR ELEVATOR 12" TYP. VERIFY W/. G.C. &
MFGR.
SLAB DEPRESSION FOR SLIDING DOORS VERIFY W/. G.C. & MFGR.
36'-0"15'-11 1/8"23'-8 3/4"
6'-1 7/8"36'-0"15'-11"23'-8 7/8"12'-11 1/2"33'-8 5/8"1'-8 3/8"5'-10 3/4"5'-1 1/4"
4'-10 5/8"18'-8"33'-7 5/8"21'-0 1/4"7'-3 1/8"
41'-5 5/8"
OA6
OA8
OA10
OA9
G
J
I
H
J1
J 2
H1OA5
OA7
OPEN AREA 4
49 sq ft
OPEN AREA 3126 sq ft
DN.UP
7'-2 1/8"3'-8 7/8"6'-9 3/8"SECOND FLOOR
A: 2,377 sq ft
DN.
35'-4 1/2"7'-4 1/8"9'-1"2'-2"1'-4 3/4"20'-9 1/4"
10'-1 7/8"3'-2 1/4"11'-8 3/4"17'-10 5/8"36'-0"7'-4 1/8"9'-0 7/8"3'-6 3/4"20'-7 1/4"32'-9 5/8"11"33'-7 5/8"3'-6 3/4"27'-0 1/4"33'-11 5/8"3'-8 5/8"4'-1 3/8"
7'-2 5/8"
A
B
D
E
F1
F2
F3
F4
OA1
OA2OA3
OPEN AREA 1
A: 49 sq ft
OPEN AREA 2
A: 209 sq ft
UP
32'-9 5/8"6'-9 3/8"C
FIRST FLOOR
A: 1,735 sq ft
3-CAR GARAGE
A: 735 sq ft
26'-5 3/4"19'-1 1/4"7'-7 3/8"9'-11 3/8"
5'-1 1/4"6'-4 5/8"12'-6 1/2"15'-0"L
M
L1
THIRD FLOOR
A: 422 sq ft
VIEW DECK SF
A: 1,023 sq ft
DN.
A 35' - 4 1/2" X 33' - 7 5/8" 1189.85
B 7' - 4 1/8" X 27' - 0 1/4" 198.43
C 9' - 1" X 32' - 9 5/8" 297.95
D 3' - 6 3/4" X 11' - 8 3/4" 41.79
E 2' - 2" X 3' - 2 1/4" 6.91
TOTAL 1734.93
F1 3' - 6 3/4" X 17' - 10 5/8" 63.72
F2 20' - 7 1/4" X 32' - 9 5/8" 675.86
F3 1' - 4 1/8" X 3' - 2 1/4" 4.28
-F4 10' - 1 7/8" X 0' - 11" -9.31
TOTAL 734.55
OA1 7' - 3 1/8" X 6' - 9 3/8" 48.95
OA2 4' - 1 3/8" X 33' - 7 5/8"138.4
OA3 62
TOTAL 249.35
G 6' - 1 7/8" X 12' - 11 1/2" 79.77
H 36' - 0" X 33' - 7 5/8" 1210.88
H1 7' - 1 1/2" X 18' - 8" -11.67
I 15' - 11 1/8" X 21' 0 1/4" 334.8
J 23' - 8 7/8" X 33' - 8 5/8" 800.47
J1 5' - 1 1/4" X 5' - 10 3/4" -30.09
J2 4' - 10 5/8" X 1' - 8 3/8" -8.3
TOTAL 2375.86
OA4 7' - 3 1/8" X 6' - 9 3/8" 49.23
OA5 76.28
OA6 1' - 0 7/8" X 0' - 3/4" 0.07
OA7 38.43
OA8 25.4
OA9 6' - 0 3/4" X 2' - 1 1/2" 12.88
OA10 0' - 1 1/4" X 15' - 2 7/8" 1.59
TOTAL 203.88
L 27' - 3 1/2" X 19' - 1 1/4" 505.86
M 9' - 5 1/4" X 7' - 7 3/8" 75.75
-L1 5' - 1 1/4" X 5' - 7 1/4" -64.01
0 5' - 1 1/4" X 5' - 7 1/4" -95.78
TOTAL 421.82
THIRD FLOOR LIVING
4' - 1 1/3" x 18' - 8"
(1' - 8" x 15' - 2 7/8")/2
(2' - 0 5/8" x 18' - 8 3/4")/2
SECOND FLOOR OPEN AREA
SECOND FLOOR LIVING
FIRST FLOOR LIVING
GARAGE
FIRST FLOOR OPEN AREA
(3' - 8 5/8" x 33' - 7 5/8")/2
A 35' - 4 1/2" X 33' - 7 5/8" 1189.85
B 7' - 4 1/8" X 27' - 0 1/4" 198.43
C 9' - 1" X 32' - 9 5/8" 297.95
D 3' - 6 3/4" X 11' - 8 3/4" 41.79
E 2' - 2" X 3' - 2 1/4" 6.91
TOTAL 1734.93
F1 3' - 6 3/4" X 17' - 10 5/8" 63.72
F2 20' - 7 1/4" X 32' - 9 5/8" 675.86
F3 1' - 4 1/8" X 3' - 2 1/4" 4.28
-F4 10' - 1 7/8" X 0' - 11" -9.31
TOTAL 734.55
OA1 7' - 3 1/8" X 6' - 9 3/8" 48.95
OA2 4' - 1 3/8" X 33' - 7 5/8"138.4
OA3 62
TOTAL 249.35
G 6' - 1 7/8" X 12' - 11 1/2" 79.77
H 36' - 0" X 33' - 7 5/8" 1210.88
H1 7' - 1 1/2" X 18' - 8" -11.67
I 15' - 11 1/8" X 21' 0 1/4" 334.8
J 23' - 8 7/8" X 33' - 8 5/8" 800.47
J1 5' - 1 1/4" X 5' - 10 3/4" -30.09
J2 4' - 10 5/8" X 1' - 8 3/8" -8.3
TOTAL 2375.86
OA4 7' - 3 1/8" X 6' - 9 3/8" 49.23
OA5 76.28
OA6 1' - 0 7/8" X 0' - 3/4" 0.07
OA7 38.43
OA8 25.4
OA9 6' - 0 3/4" X 2' - 1 1/2" 12.88
OA10 0' - 1 1/4" X 15' - 2 7/8" 1.59
TOTAL 203.88
L 27' - 3 1/2" X 19' - 1 1/4" 505.86
M 9' - 5 1/4" X 7' - 7 3/8" 75.75
-L1 5' - 1 1/4" X 5' - 7 1/4" -64.01
0 5' - 1 1/4" X 5' - 7 1/4" -95.78
TOTAL 421.82
THIRD FLOOR LIVING
4' - 1 1/3" x 18' - 8"
(1' - 8" x 15' - 2 7/8")/2
(2' - 0 5/8" x 18' - 8 3/4")/2
SECOND FLOOR OPEN AREA
SECOND FLOOR LIVING
FIRST FLOOR LIVING
GARAGE
FIRST FLOOR OPEN AREA
(3' - 8 5/8" x 33' - 7 5/8")/2
A 35' - 4 1/2" X 33' - 7 5/8" 1189.85
B 7' - 4 1/8" X 27' - 0 1/4" 198.43
C 9' - 1" X 32' - 9 5/8" 297.95
D 3' - 6 3/4" X 11' - 8 3/4" 41.79
E 2' - 2" X 3' - 2 1/4" 6.91
TOTAL 1734.93
F1 3' - 6 3/4" X 17' - 10 5/8" 63.72
F2 20' - 7 1/4" X 32' - 9 5/8" 675.86
F3 1' - 4 1/8" X 3' - 2 1/4" 4.28
-F4 10' - 1 7/8" X 0' - 11" -9.31
TOTAL 734.55
OA1 7' - 3 1/8" X 6' - 9 3/8" 48.95
OA2 4' - 1 3/8" X 33' - 7 5/8"138.4
OA3 62
TOTAL 249.35
G 6' - 1 7/8" X 12' - 11 1/2" 79.77
H 36' - 0" X 33' - 7 5/8" 1210.88
H1 7' - 1 1/2" X 18' - 8" -11.67
I 15' - 11 1/8" X 21' 0 1/4" 334.8
J 23' - 8 7/8" X 33' - 8 5/8" 800.47
J1 5' - 1 1/4" X 5' - 10 3/4" -30.09
J2 4' - 10 5/8" X 1' - 8 3/8" -8.3
TOTAL 2375.86
OA4 7' - 3 1/8" X 6' - 9 3/8" 49.23
OA5 76.28
OA6 1' - 0 7/8" X 0' - 3/4" 0.07
OA7 38.43
OA8 25.4
OA9 6' - 0 3/4" X 2' - 1 1/2" 12.88
OA10 0' - 1 1/4" X 15' - 2 7/8" 1.59
TOTAL 203.88
L 27' - 3 1/2" X 19' - 1 1/4" 505.86
M 9' - 5 1/4" X 7' - 7 3/8" 75.75
-L1 5' - 1 1/4" X 5' - 7 1/4" -64.01
0 5' - 1 1/4" X 5' - 7 1/4" -95.78
TOTAL 421.82
THIRD FLOOR LIVING
4' - 1 1/3" x 18' - 8"
(1' - 8" x 15' - 2 7/8")/2
(2' - 0 5/8" x 18' - 8 3/4")/2
SECOND FLOOR OPEN AREA
SECOND FLOOR LIVING
FIRST FLOOR LIVING
GARAGE
FIRST FLOOR OPEN AREA
(3' - 8 5/8" x 33' - 7 5/8")/2
BUILDING AREA
LIVING
GARAGE
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
3-CAR GARAGE
1,735
2,376
422
4,532 sq ft
735
735 sq ft
5,267 sq ft
SCALE: 3/16" = 1'-0"2SECOND LEVEL AREA PLAN
SCALE: 3/16" = 1'-0"1FIRST LEVEL AREA PLAN
SCALE: 3/16" = 1'-0"3THIRD LEVEL AREA PLAN
PA2021-013
BRANDON ARCHITECTS
DATE
A-1.0
PROJECT CONTACT
JEFF VAN VOORHIS, AIA
PROJECT NAME
PROJECT ADDRESS
908 W. OCEANFRONT
NEWPORT BEACH, CA 92661
OWNER INFORMATION
908 NB PROPERTY MANAGEMENT LLC
3717 EUCLID AVE.
DALLAS, TX
PROJECT STATUS
CDP
PLAN CHECK NO.
TBD
REVISIONS
NO.
DATE
1/27/2021 HARVEY RESIDENCE3D VIEWS
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
REVISIONS
These documents are the property of BRANDON
ARCHITECTS INC., and are not to be duplicated,
altered or utilized in any ay by any other party
without the expressed authorization of
BRANDON ARCHITECTS. Any unauthorized
duplication or alteration of these documents by
any party is a violation of BRANDON
ARCHITECTS expressed common law copyright
and other property rights thereto, and is subject
to full civil liabilities and penalties. These plans
are also not to be assigned to any third party
without obtaining written authorization and
expressed permission by BRANDON
ARCHITECTS, who shall then be held harmless
and absolved of any liability regarding any use
of these documents by such third party whether
depicted or implied hereon.
SCALE: 1/8" = 1'-0"1NORTHEAST AXONOMETRIC
SCALE: 1/8" = 1'-0"2SOUTHEAST AXONOMETRIC
SCALE: 1/8" = 1'-0"4NORTHWEST AXONOMETRIC
SCALE: 1/8" = 1'-0"3SOUTHWEST AXONOMETRIC
PA2021-013
BRANDON ARCHITECTS
DATE
A-2.1
PROJECT CONTACT
JEFF VAN VOORHIS, AIA
PROJECT NAME
PROJECT ADDRESS
908 W. OCEANFRONT
NEWPORT BEACH, CA 92661
OWNER INFORMATION
908 NB PROPERTY MANAGEMENT LLC
3717 EUCLID AVE.
DALLAS, TX
PROJECT STATUS
CDP
PLAN CHECK NO.
TBD
REVISIONS
NO.
DATE
1/27/2021 HARVEY RESIDENCEFIRST & SECOND
LEVEL FLOOR PLAN
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
REVISIONS
These documents are the property of BRANDON
ARCHITECTS INC., and are not to be duplicated,
altered or utilized in any ay by any other party
without the expressed authorization of
BRANDON ARCHITECTS. Any unauthorized
duplication or alteration of these documents by
any party is a violation of BRANDON
ARCHITECTS expressed common law copyright
and other property rights thereto, and is subject
to full civil liabilities and penalties. These plans
are also not to be assigned to any third party
without obtaining written authorization and
expressed permission by BRANDON
ARCHITECTS, who shall then be held harmless
and absolved of any liability regarding any use
of these documents by such third party whether
depicted or implied hereon.
A GENERAL NOTES
C KEYNOTES
B ANNOTATION LEGEND
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE NEAREST
1/8" - CONTACT ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
ROUGH FRAMING:
ALL EXTERIOR WALLS TO BE FRAMED WITH 2 X 6 STUDS
SECOND AND THIRD FLOOR PLYWOOD TO BE 1-1/8"
ENTIRE EXTERIOR TO BE SHEATHED WITH 1/2" PLYWOOD
DUCTS PENETRATION:
DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE
CONSTRUCTED OF A MINIMUM NO. 26 GAGE (0.48 MM) SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL NOT HAVE
OPENINGS INTO THE GARAGE (R302.5.2)
STAIRWAY ILLUMINATION:
1.INTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE TO ILLUMINATE THE LANDINGS AND TREADS. THE
LIGHT SOURCE SHALL BE CAPABLE OF ILLUMINATING TREADS AND LANDINGS TO LEVELS OF NOT LESS THAN 1 FOOT-CANDLE (11
LUX) AS MEASURED AT THE CENTER OF TREADS AND LANDINGS. THERE SHALL BE A WALL SWITCH AT EACH FLOOR LEVEL TO
CONTROL THE LIGHT SOURCE WHERE THE STAIRWAY HAS SIX OR MORE RISERS. (R303.7)
EXCEPTION: A SWITCH IS NOT REQUIRED WHERE REMOTE, CENTRAL OR AUTOMATIC CONTROL OF LIGHTING IS
PROVIDED.
2.EXTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE TOP LANDING OF THE STAIRWAY.
EXTERIOR STAIRWAYS PROVIDING ACCESS TO A BASEMENT FROM THE OUTDOOR GRADE LEVEL SHALL BE PROVIDED WITH AN
ARTIFICIAL LIGHT SOURCE LOCATED AT THE BOTTOM LANDING OF THE STAIRWAY. (R303.8)
GARAGE FLOOR:
GARAGE FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTIBLE MATERIAL.THE AREA OF FLOOR USED FOR PARKING OF
AUTOMOBILES OR OTHER VEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS TO A DRAIN OR TOWARD THE MAIN
VEHICLE ENTRY DOORWAY. (R309.1)
*HERS VERIFICATION REQUIRED- REFERENCE T-24.1
PROJECT NORTHTRUE NORTH
ROOM NAME
UP
20R x 7 1/2"NN
15'-6"
1
A-4.0
N90° 00' 00"E 78.25'
1
01.13
1i
ELEVATION/SECTION INDICATOR
WINDOW TAG
DOOR TAG
ROOM TAG
PROPERTY LINE TAG
STAIR TAG (NO. OF RISER & HEIGHT)
KEYNOTE TAG
SPOT ELEVATION
DN.3R x 6"
4
4
2
3
6
6
21
1
8
10
9
7
11
5
5
33'-0"S.Y.S.B.3'-0"S.Y.S.B.8'-0"
F.Y.S.B.
20'-6 3/4"CLR.31'-5"CLR.23'-6 3/4"CLR.17'-10 1/8"CLR.2
A-5.0
2
A-5.0
4
A-5.0
4
A-5.0
6
A-5.1
6
A-5.1
7
A-5.2
7
A-5.2
3
A-5.1
3
A-5.1
2
A-5.0
2
A-5.0
5
A-5.1
5
A-5.1
1
A-4.0
2
A-4.0
4
A-4.0
3
A-4.0
01.01
01.01
01.02
01.04
01.04
34.01
12.01
11.22
06.42
11.05
10.12
06.26
22.03
03.06
14.01
03.1211.09
23.02
06.42
06.43
06.34
06.46
22.06
11.13
11.11
11.06
11.07
11.02
06.46
06.37
06.32
22.08
06.45
10.08
22.05
22.20
03.12 03.12
03.06
03.04
3-CAR GARAGE
SAND ROOM
ELEV.
PWDR.
GREATROOM
DINING
KITCHEN
LOUNGE ENTRY STAIRS
PANTRY
UP17R x 7 3/8"37
28
29
26
19
24
98 10
27
20
18 21
23
24
22
13
1415
1920
23
17 1618 15
11
12
16
17
25
22
21
18.1
21.1
2
A-5.0
2
A-5.0
4
A-5.0
4
A-5.0
6
A-5.1
6
A-5.1
7
A-5.2
7
A-5.2
3
A-5.1
3
A-5.1
2
A-5.0
2
A-5.0
5
A-5.1
5
A-5.1
1
A-4.0
2
A-4.0
4
A-4.0
3
A-4.03'-0"S.Y.S.B.3'-0"S.Y.S.B.8'-0"
F.Y.S.B.
2% MIN.
10.04
06.48
22.05
22.20
06.48
22.05
22.20
06.48
22.05
22.20
06.48
22.05
22.20
06.48
22.05
22.20
06.45 06.45
22.08
22.08
22.08
06.45
01.01
12.01
12.01
08.0501.0401.01
22.08
06.45
08.05
08.0501.0101.0408.0508.05
01.01
01.02
10.01
09.24
11.21
11.04
11.04
22.10
06.38
06.38
12.01
12.01
06.42
06.26
06.42 06.26
06.42
06.26
06.42 06.38
06.38
06.45
22.04
12.01
22.08
06.31
12.01
10.12
12.01
06.47
OPEN TO BLW.
RETREAT/OFFICE
STAIRS
ELEV.BED #2
BED #3
BATH #3
W.I.C.
BATH #4
BATH #2
BED #4
LNDRY.
MASTER W.I.C.
MASTER BATH
W/C.
MASTER SUITE
BED #5
BATH #5
W.I.C.
MECH.
10.07
DN.17R x 7 3/8"UP 16R x 6 7/8"12
KEYNOTES
GENERAL NOTES
01.01 PROPERTY LINE
01.02 FRONT YARD SETBACK
01.04 SIDE YARD SETBACK
CONCRETE
03.04 DEPRESSED SLAB/STRUCTURE FOR FIREPLACE
COORD. WITH MFG'R. & GENERAL CONTRACTOR, REF. STRUCT. DWGS.
03.06 DEPRESSED SLAB FOR ELEVATOR
12". COORD. WITH ELEVATOR MFG. & G.C., REF. STRUCT. DRAWINGS
03.12 DEPRESS SLAB
FOR PEDESTAL FLOOR SYSTEM. REF. CIVIL AND SLAB EDGE PLAN
WOOD, PLASTICS, & COMPOSITES
06.26 BASE CABINET
SINK UNIT, BUILT-IN, FINISH AS SEL.
06.31 DESK
BUILT-IN, FINISH AS SEL.
06.32 DISPLAY SHELVES
CUSTOM - FINISH AS SELECTED
06.34 KITCHEN ISLAND
BASE CABINET, COUNTER, AND APPLIANCES PER I.D - VERIFY SIZE W/. I.D. & OWNER
06.37 PANTRY SHELVES
AS SEL. BY OWNER
06.38 BUILT-IN CLOSET
CUSTOM PER INTERIOR DESIGNER
06.42 UPPER CABINET
BUILT-IN, FINISH AS SEL.
06.43 BASE CABINET
BUILT-IN, FINISH AS SEL.
06.45 VANITY CASEWORK
SINK, BASE CABINET AND COUNTER - VERIFY SIZE W/. I.D. & OWNER
06.46 KITCHEN SINK CASEWORK
SINK, BASE CABINET AND COUNTER - VERIFY SIZE/. I.D. & OWNER
06.47 TOWEL RACK PER I.D.
CUSTOM RACK AND SHELVES PER I.D.
06.48 DEPRESS STRUCTURE FOR FLUSH SHOWER CONDITION
COORD. WITH I.D. & GENERAL CONTRACTOR, REF. STRUCT. DWGS.
OPENINGS
08.05 WINDOW TO MEET EGRESS REQUIREMENTS
REF. DOOR AND WINDOW NOTES #6, SHT. A-7.0
FINISHES
09.24 TILE/STONE PAVERS
ON CONCRETE SETTING BED O/ WATERPROOF MEMBRANE REF. MAT. SCHEDULE (CLASS 'A' ASSEMBLY)
SPECIALTIES
10.01 EXTERIOR GLASS GUARDRAIL
TEMPERED & LAMINATED - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
10.04 INTERIOR GLASS GUARDRAIL
MIN. 42" HIGH - MATERIAL AS SELECTED, <4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
10.07 STAIRS
MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT
CANDLE (CBC 1205.4) REF. DTL. 3/AD-1
10.08 CUSTOM STEEL STRINGER STAIR
4" MAX OPENING BETWEEN TREADS. REF. STRUCT. DTL.- ARCH TO APPRV. SHOP DWGS
10.12 CUSTOM WOOD SCREEN
WOOD SCREEN PER I.D. ARCH TO APPV. SHOP DWGS. PRIOR TO FABRICATION
EQUIPMENT
11.02 BUILT-IN COFFEE MAKER
PROVIDE WATER & POWER - COORDINATE W/. I.D.
11.04 WASHER/DRYER
PROVIDE 4" MIN. DIA. DUCT, 14' MAX. LENGTH INCLUDING (2) 90 DEGREE ELBOWS, DEDUCT TWO(2) FEET FOR EACH
90 DEGREE ELBOW IN EXCESS OF TWO(2) (CMC 504.3.2)
11.05 WINE FRIDGE
VERIFY APPLIANCE W/. OWNER
11.06 FREEZER
VERIFY APPLIANCE W/. OWNER
11.07 MICROWAVE OVEN
VERIFY APPLIANCE W/. OWNER
11.09 RANGE
VERIFY APPLIANCE W/. OWNER - PROVIDE HOOD CAPABLE OF 100 CFM MIN. (VERIFY W/. MFG.) - VENT TO OUTDOOR
AIR
11.11 REFRIGERATOR
VERIFY APPLIANCE W/. OWNER
11.13 TRASH COMPACTOR
VERIFY APPLIANCE W/. OWNER
11.21 FIREPLACE
PREFABRICATED, GAS ONLY, 'FLARE - CORNER ' [DTL. 22/AD-1] (FACTORY BUILT FIREPLACES, CHIMNEYS, AND ALL OF
THEIR COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE W/. THEIR LISTING AND MFG'R.
INSTALLATION INSTRUCTIONS. GASEOUS FUEL BURNING PAN MUST BE PERMANENTLY ANCHORED TO THE FIREBOX.
FIREPLACE MUST COMPLY W/. THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES.)
11.22 FIREPLACE
PREFABRICATED, GAS ONLY, 'FLARE - FF-45-H' - ANSI Z21.50B-2014 [DTL. 22/AD-1] (FACTORY BUILT FIREPLACES,
CHIMNEYS AND ALL OF THEIR COMPONENTS SHALL BE LISTED AN INSTALLED IN ACCORDANCE W/. THEIR LISTING
AND MFG'R. INSTALLATION INSTRUCTIONS. GASEOUS FUEL BURNING PAN MUST BE PERMANENTLY ANCHORED TO
THE FIREBOX. FIREPLACE MUST COMPLY W/. THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES.)
FURNISHINGS
12.01 FURNISHINGS
AS SELECTED
CONVEYING EQUIPMENT
14.01 RESIDENTIAL ELEVATOR
'CALIFORNIA CUSTOM LIFT, INC.' OR EQUIV., SHAFT SIZE = 56"" X 60"" CLEAR - PROVIDE SHOP DWGS. TO ARCH.
PRIOR TO PURCHASE & INSTALLATION
PLUMBING
22.03 BAR SINK
AS SELECTED
22.04 BATHTUB
FREE-STANDING, AS SELECTED (VERIFY LOC'N. OF FIXTURES W/. OWNER)
22.05 SHOWER
PROVIDE TILE W/. CEMENT BACKING MIN. 72" HIGH (R307.2)
22.06 DISHWASHER
AS SELECTED
22.08 TOILET
MIN. 24" CLR. IN FRONT, MIN. 30"" CLR. WIDTH, REF. CAL GREEN NOTES FOR FLOW RATE INFO.
22.10 LAUNDRY SINK
AS SELECTED
22.20 CUSTOM SHOWER SEAT
SEAT PER I.D.
HEATING VENTILATING & AIR CONDITIONING
23.02 KITCHEN EXHAUST HOOD
TO VENT TO EXT. - PROVIDE MIN. RATE OF 100 CFM - INSTALL & PROVIDE POWER PER MFG. INSTRUCTION
TRANSPORTATION
34.01 VEHICLE
MINIMUM PARKING DIMENSIONS ON PLANS
SCALE: 1/4" = 1'-0"1FIRST LEVEL FLOOR PLAN
SCALE: 1/4" = 1'-0"2SECOND LEVEL FLOOR PLAN
PA2021-013
BRANDON ARCHITECTS
DATE
A-2.2
PROJECT CONTACT
JEFF VAN VOORHIS, AIA
PROJECT NAME
PROJECT ADDRESS
908 W. OCEANFRONT
NEWPORT BEACH, CA 92661
OWNER INFORMATION
908 NB PROPERTY MANAGEMENT LLC
3717 EUCLID AVE.
DALLAS, TX
PROJECT STATUS
CDP
PLAN CHECK NO.
TBD
REVISIONS
NO.
DATE
1/27/2021 HARVEY RESIDENCETHIRD LEVEL FLOOR
PLAN
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
REVISIONS
These documents are the property of BRANDON
ARCHITECTS INC., and are not to be duplicated,
altered or utilized in any ay by any other party
without the expressed authorization of
BRANDON ARCHITECTS. Any unauthorized
duplication or alteration of these documents by
any party is a violation of BRANDON
ARCHITECTS expressed common law copyright
and other property rights thereto, and is subject
to full civil liabilities and penalties. These plans
are also not to be assigned to any third party
without obtaining written authorization and
expressed permission by BRANDON
ARCHITECTS, who shall then be held harmless
and absolved of any liability regarding any use
of these documents by such third party whether
depicted or implied hereon.
A GENERAL NOTES
C KEYNOTES
B ANNOTATION LEGEND
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE NEAREST
1/8" - CONTACT ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
ROUGH FRAMING:
ALL EXTERIOR WALLS TO BE FRAMED WITH 2 X 6 STUDS
SECOND AND THIRD FLOOR PLYWOOD TO BE 1-1/8"
ENTIRE EXTERIOR TO BE SHEATHED WITH 1/2" PLYWOOD
DUCTS PENETRATION:
DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE
CONSTRUCTED OF A MINIMUM NO. 26 GAGE (0.48 MM) SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL NOT HAVE
OPENINGS INTO THE GARAGE (R302.5.2)
STAIRWAY ILLUMINATION:
1.INTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE TO ILLUMINATE THE LANDINGS AND TREADS. THE
LIGHT SOURCE SHALL BE CAPABLE OF ILLUMINATING TREADS AND LANDINGS TO LEVELS OF NOT LESS THAN 1 FOOT-CANDLE (11
LUX) AS MEASURED AT THE CENTER OF TREADS AND LANDINGS. THERE SHALL BE A WALL SWITCH AT EACH FLOOR LEVEL TO
CONTROL THE LIGHT SOURCE WHERE THE STAIRWAY HAS SIX OR MORE RISERS. (R303.7)
EXCEPTION: A SWITCH IS NOT REQUIRED WHERE REMOTE, CENTRAL OR AUTOMATIC CONTROL OF LIGHTING IS
PROVIDED.
2.EXTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE TOP LANDING OF THE STAIRWAY.
EXTERIOR STAIRWAYS PROVIDING ACCESS TO A BASEMENT FROM THE OUTDOOR GRADE LEVEL SHALL BE PROVIDED WITH AN
ARTIFICIAL LIGHT SOURCE LOCATED AT THE BOTTOM LANDING OF THE STAIRWAY. (R303.8)
GARAGE FLOOR:
GARAGE FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTIBLE MATERIAL.THE AREA OF FLOOR USED FOR PARKING OF
AUTOMOBILES OR OTHER VEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS TO A DRAIN OR TOWARD THE MAIN
VEHICLE ENTRY DOORWAY. (R309.1)
*HERS VERIFICATION REQUIRED- REFERENCE T-24.1
PROJECT NORTHTRUE NORTH
ROOM NAME
UP
20R x 7 1/2"NN
15'-6"
1
A-4.0
N90° 00' 00"E 78.25'
1
01.13
1i
ELEVATION/SECTION INDICATOR
WINDOW TAG
DOOR TAG
ROOM TAG
PROPERTY LINE TAG
STAIR TAG (NO. OF RISER & HEIGHT)
KEYNOTE TAG
SPOT ELEVATION
7
31
32
26
33
34
25
30
28 27
2
A-5.0
2
A-5.0
4
A-5.0
4
A-5.0
6
A-5.1
6
A-5.1
7
A-5.2
7
A-5.2
3
A-5.1
3
A-5.1
2
A-5.0
2
A-5.0
5
A-5.1
5
A-5.1
1
A-4.0
2
A-4.0
4
A-4.0
3
A-4.03'-0"S.Y.S.B.3'-0"S.Y.S.B.8'-0"
F.Y.S.B.
01.01
01.01
01.01
01.01
01.02
01.04
01.04
09.31
09.3109.28
09.28
10.01
10.01
23.07
23.07
12.01
10.04
10.07 2% MIN.2% MIN.
2% MIN.1:121:12
1:123:122% MIN.2% MIN.2% MIN.2% MIN.06.48
22.05
22.20
09.31
05.07
22.19
22.19
22.192% MIN.2% MIN.05.07
05.07 05.06
05.06
OPEN TO BLW.
BONUS ROOM
ELEV.
MECH.
MECH.
BATH #3
DN.16R x 6 7/8"STAIRS
KEYNOTES
GENERAL NOTES
01.01 PROPERTY LINE
01.02 FRONT YARD SETBACK
01.04 SIDE YARD SETBACK
WOOD, PLASTICS, & COMPOSITES
06.48 DEPRESS STRUCTURE FOR FLUSH SHOWER CONDITION
COORD. WITH I.D. & GENERAL CONTRACTOR, REF. STRUCT. DWGS.
FINISHES
09.28 STANDING SEAM METAL ROOFING
REF. MAT. SCHEDULE SHT. A-4.0
09.31 FLAT COOL ROOF
CLASS 'A' - COLOR AS SELECTED - TPO MEMBRANE - REF. MAT. SCHEDULE SHT. A-4.0
SPECIALTIES
10.01 EXTERIOR GLASS GUARDRAIL
TEMPERED & LAMINATED - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
10.04 INTERIOR GLASS GUARDRAIL
MIN. 42" HIGH - MATERIAL AS SELECTED, <4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
10.07 STAIRS
MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT
CANDLE (CBC 1205.4) REF. DTL. 3/AD-1
FURNISHINGS
12.01 FURNISHINGS
AS SELECTED
PLUMBING
22.05 SHOWER
PROVIDE TILE W/. CEMENT BACKING MIN. 72" HIGH (R307.2)
22.20 CUSTOM SHOWER SEAT
SEAT PER I.D.
HEATING VENTILATING & AIR CONDITIONING
23.07 FAU
PROVIDE GAS S.O., POWER, AND VENTING AS REQ'D. BY MFG'R.
SCALE: 1/4" = 1'-0"1THIRD LEVEL FLOOR PLAN
PA2021-013
BRANDON ARCHITECTS
DATE
A-2.3
PROJECT CONTACT
JEFF VAN VOORHIS, AIA
PROJECT NAME
PROJECT ADDRESS
908 W. OCEANFRONT
NEWPORT BEACH, CA 92661
OWNER INFORMATION
908 NB PROPERTY MANAGEMENT LLC
3717 EUCLID AVE.
DALLAS, TX
PROJECT STATUS
CDP
PLAN CHECK NO.
TBD
REVISIONS
NO.
DATE
1/27/2021 HARVEY RESIDENCEFIRST & SECOND
LEVEL DIMENSION
PLAN
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
REVISIONS
These documents are the property of BRANDON
ARCHITECTS INC., and are not to be duplicated,
altered or utilized in any ay by any other party
without the expressed authorization of
BRANDON ARCHITECTS. Any unauthorized
duplication or alteration of these documents by
any party is a violation of BRANDON
ARCHITECTS expressed common law copyright
and other property rights thereto, and is subject
to full civil liabilities and penalties. These plans
are also not to be assigned to any third party
without obtaining written authorization and
expressed permission by BRANDON
ARCHITECTS, who shall then be held harmless
and absolved of any liability regarding any use
of these documents by such third party whether
depicted or implied hereon.
A GENERAL NOTES
C KEYNOTES
B ANNOTATION LEGEND
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE NEAREST
1/8" - CONTACT ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
ROUGH FRAMING:
ALL EXTERIOR WALLS TO BE FRAMED WITH 2 X 6 STUDS
SECOND AND THIRD FLOOR PLYWOOD TO BE 1-1/8"
ENTIRE EXTERIOR TO BE SHEATHED WITH 1/2" PLYWOOD
DUCTS PENETRATION:
DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE
CONSTRUCTED OF A MINIMUM NO. 26 GAGE (0.48 MM) SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL NOT HAVE
OPENINGS INTO THE GARAGE (R302.5.2)
STAIRWAY ILLUMINATION:
1.INTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE TO ILLUMINATE THE LANDINGS AND TREADS. THE
LIGHT SOURCE SHALL BE CAPABLE OF ILLUMINATING TREADS AND LANDINGS TO LEVELS OF NOT LESS THAN 1 FOOT-CANDLE (11
LUX) AS MEASURED AT THE CENTER OF TREADS AND LANDINGS. THERE SHALL BE A WALL SWITCH AT EACH FLOOR LEVEL TO
CONTROL THE LIGHT SOURCE WHERE THE STAIRWAY HAS SIX OR MORE RISERS. (R303.7)
EXCEPTION: A SWITCH IS NOT REQUIRED WHERE REMOTE, CENTRAL OR AUTOMATIC CONTROL OF LIGHTING IS
PROVIDED.
2.EXTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE TOP LANDING OF THE STAIRWAY.
EXTERIOR STAIRWAYS PROVIDING ACCESS TO A BASEMENT FROM THE OUTDOOR GRADE LEVEL SHALL BE PROVIDED WITH AN
ARTIFICIAL LIGHT SOURCE LOCATED AT THE BOTTOM LANDING OF THE STAIRWAY. (R303.8)
GARAGE FLOOR:
GARAGE FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTIBLE MATERIAL.THE AREA OF FLOOR USED FOR PARKING OF
AUTOMOBILES OR OTHER VEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS TO A DRAIN OR TOWARD THE MAIN
VEHICLE ENTRY DOORWAY. (R309.1)
*HERS VERIFICATION REQUIRED- REFERENCE T-24.1
PROJECT NORTHTRUE NORTH
ROOM NAME
UP
20R x 7 1/2"NN
15'-6"
1
A-4.0
N90° 00' 00"E 78.25'
1
01.13
1i
ELEVATION/SECTION INDICATOR
WINDOW TAG
DOOR TAG
ROOM TAG
PROPERTY LINE TAG
STAIR TAG (NO. OF RISER & HEIGHT)
KEYNOTE TAG
SPOT ELEVATION
DN.
4
4
2
3
6
6
21
1
8
10
9
7
11
5
5
3
1'-3 1/2"16'-7 5/8"17'-6 7/8"8 1/8"2'-6"4'-3 7/8"2'-7 7/8"2'-8"5'-9 3/4"3'-11 1/8"7'-0"1'-5 1/2"8'-4 7/8"1'-8"
35'-6"7'-6"11'-1 5/8"22'-5 1/2"
12'-0"76'-7 1/8"5 3/4"
1'-3 1/2"5'-6 1/8"7'-8"5'-3 7/8"4'-7 1/2"6'-0 1/2"5'-6 1/2"1'-2 5/8"4'-11 3/8"1'-2 1/8"6 3/4"8'-0 5/8"2'-6 1/8"2'-6"19'-7 3/8"
36'-0"7'-4 1/8"8'-7 3/8"24'-7 1/2"
16'-4 1/2"76'-7 1/8"4 7/8"1'-5"7 5/8"9'-0"1'-8 3/8"18'-0"2'-0 5/8"2'-0 5/8"30'-9"3'-2"32'-9 5/8"4'-0"5'-3"26'-6"1'-10 5/8"33'-7 5/8"3'-2"33'-7 5/8"3'-2"8'-0"
F.Y.S.B.3'-0"S.Y.S.B.3'-0"S.Y.S.B.03.12 03.12
03.06
03.04
3-CAR GARAGE
SAND ROOM
ELEV.
PWDR.
GREATROOM
DINING
KITCHEN
LOUNGE ENTRY STAIRS
PANTRY
UP
37
28
29
26
19
24
98 10
27
20
18 21
23
24
22
13
1415
1920
23
17 1618 15
11
12
16
17
25
22
21
18.1
21.1
5'-7 1/2"4'-7"9'-7"3'-11"
4'-9 3/4"23'-8 5/8"12'-3 3/8"7'-4 1/8"8'-6 7/8"24'-6 7/8"
16'-4 1/2"76'-5 7/8"6 1/8"
3'-1 7/8"3'-0 1/2"6'-11 1/2"3'-0 1/2"1'-9 3/8"8"
2'-8 3/4"7'-0"2'-8 3/4"2'-11 3/8"2'-6"2'-6 5/8"2'-2 7/8"7'-0"1'-9 3/8"5'-9 5/8"2'-0"3'-8 1/2"13'-6 1/4"1'-4"
4'-9 3/4"17'-11 3/4"13'-1 1/2"8'-0"11'-0 3/8"11'-6"14'-10 1/4"
12'-0"76'-5 7/8"6 7/8"4'-3 5/8"10'-3 5/8"3'-2"36'-9 5/8"14'-7 1/4"6'-9"12'-4 3/8"6 3/4"8'-0 1/8"9 5/8"2'-0"6'-11"9 1/8"2'-6"7'-3 3/8"2'-6"5 3/4"1'-4"
1'-4"4'-7"10"13'-3"15'-1 5/8"18'-8"15'-1 5/8"3'-0"33'-9 5/8"2'-10 3/8"8'-0"
F.Y.S.B.3'-0"S.Y.S.B.3'-0"S.Y.S.B.10'-2 5/8"2'-1 3/4"RETREAT/OFFICE
STAIRS
ELEV.BED #2
BED #3
BATH #3
W.I.C.
BATH #4
BATH #2
BED #4
LNDRY.
MASTER W.I.C.
MASTER BATH
W/C.
MASTER SUITE
BED #5
BATH #5
W.I.C.
MECH.
DN.UP
12
KEYNOTES
CONCRETE
03.04 DEPRESSED SLAB/STRUCTURE FOR FIREPLACE
COORD. WITH MFG'R. & GENERAL CONTRACTOR, REF. STRUCT. DWGS.
03.06 DEPRESSED SLAB FOR ELEVATOR
12". COORD. WITH ELEVATOR MFG. & G.C., REF. STRUCT. DRAWINGS
03.12 DEPRESS SLAB
FOR PEDESTAL FLOOR SYSTEM. REF. CIVIL AND SLAB EDGE PLAN
WOOD, PLASTICS, & COMPOSITES
06.48 DEPRESS STRUCTURE FOR FLUSH SHOWER CONDITION
COORD. WITH I.D. & GENERAL CONTRACTOR, REF. STRUCT. DWGS.
SCALE: 1/4" = 1'-0"1FIRST LEVEL DIMENSION PLAN
SCALE: 1/4" = 1'-0"2SECOND LEVEL DIMENSION PLAN
PA2021-013
BRANDON ARCHITECTS
DATE
A-2.4
PROJECT CONTACT
JEFF VAN VOORHIS, AIA
PROJECT NAME
PROJECT ADDRESS
908 W. OCEANFRONT
NEWPORT BEACH, CA 92661
OWNER INFORMATION
908 NB PROPERTY MANAGEMENT LLC
3717 EUCLID AVE.
DALLAS, TX
PROJECT STATUS
CDP
PLAN CHECK NO.
TBD
REVISIONS
NO.
DATE
1/27/2021 HARVEY RESIDENCETHIRD LEVEL
DIMENSION PLAN
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
REVISIONS
These documents are the property of BRANDON
ARCHITECTS INC., and are not to be duplicated,
altered or utilized in any ay by any other party
without the expressed authorization of
BRANDON ARCHITECTS. Any unauthorized
duplication or alteration of these documents by
any party is a violation of BRANDON
ARCHITECTS expressed common law copyright
and other property rights thereto, and is subject
to full civil liabilities and penalties. These plans
are also not to be assigned to any third party
without obtaining written authorization and
expressed permission by BRANDON
ARCHITECTS, who shall then be held harmless
and absolved of any liability regarding any use
of these documents by such third party whether
depicted or implied hereon.
A GENERAL NOTES
C KEYNOTES
B ANNOTATION LEGEND
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE NEAREST
1/8" - CONTACT ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
ROUGH FRAMING:
ALL EXTERIOR WALLS TO BE FRAMED WITH 2 X 6 STUDS
SECOND AND THIRD FLOOR PLYWOOD TO BE 1-1/8"
ENTIRE EXTERIOR TO BE SHEATHED WITH 1/2" PLYWOOD
DUCTS PENETRATION:
DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE
CONSTRUCTED OF A MINIMUM NO. 26 GAGE (0.48 MM) SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL NOT HAVE
OPENINGS INTO THE GARAGE (R302.5.2)
STAIRWAY ILLUMINATION:
1.INTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE TO ILLUMINATE THE LANDINGS AND TREADS. THE
LIGHT SOURCE SHALL BE CAPABLE OF ILLUMINATING TREADS AND LANDINGS TO LEVELS OF NOT LESS THAN 1 FOOT-CANDLE (11
LUX) AS MEASURED AT THE CENTER OF TREADS AND LANDINGS. THERE SHALL BE A WALL SWITCH AT EACH FLOOR LEVEL TO
CONTROL THE LIGHT SOURCE WHERE THE STAIRWAY HAS SIX OR MORE RISERS. (R303.7)
EXCEPTION: A SWITCH IS NOT REQUIRED WHERE REMOTE, CENTRAL OR AUTOMATIC CONTROL OF LIGHTING IS
PROVIDED.
2.EXTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE TOP LANDING OF THE STAIRWAY.
EXTERIOR STAIRWAYS PROVIDING ACCESS TO A BASEMENT FROM THE OUTDOOR GRADE LEVEL SHALL BE PROVIDED WITH AN
ARTIFICIAL LIGHT SOURCE LOCATED AT THE BOTTOM LANDING OF THE STAIRWAY. (R303.8)
GARAGE FLOOR:
GARAGE FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTIBLE MATERIAL.THE AREA OF FLOOR USED FOR PARKING OF
AUTOMOBILES OR OTHER VEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS TO A DRAIN OR TOWARD THE MAIN
VEHICLE ENTRY DOORWAY. (R309.1)
*HERS VERIFICATION REQUIRED- REFERENCE T-24.1
PROJECT NORTHTRUE NORTH
ROOM NAME
UP
20R x 7 1/2"NN
15'-6"
1
A-4.0
N90° 00' 00"E 78.25'
1
01.13
1i
ELEVATION/SECTION INDICATOR
WINDOW TAG
DOOR TAG
ROOM TAG
PROPERTY LINE TAG
STAIR TAG (NO. OF RISER & HEIGHT)
KEYNOTE TAG
SPOT ELEVATION
7
31
32
26
33
34
25
30
28 27
46'-7 1/2"27'-3 1/2"15'-1 7/8"
1'-4"6"
2'-6"8'-2 1/8"2'-6"6"5'-4 3/4"6'-4 5/8"25'-2 1/4"5'-9 3/8"5'-0"30'-11 5/8"4'-0"14'-8 1/2"6'-4 3/4"5'-7 3/8"4'-2"5'-1"26'-8 5/8"8'-2"1'-4 1/2"7'-4 1/8"6 1/2"8'-0 1/4"6 5/8"
20'-1 3/8"14'-9"8'-8 5/8"9'-1 3/8"9'-5 3/8"
2'-6 1/8"2'-6"4'-5 1/4"
51'-0"27'-3 1/2"15'-1"
20'-0 3/8"14'-10"15'-6 1/8"11'-9 3/8"30'-5 1/4"8'-0"
F.Y.S.B.3'-0"S.Y.S.B.3'-0"S.Y.S.B.BONUS ROOM
ELEV.
MECH.
MECH.
BATH #3
DN.
STAIRS
NOTES
WOOD, PLASTICS, & COMPOSITES
06.01.07 10X14 TIMBER BEAM
REF. STRUCT. DWGS.
SCALE: 1/4" = 1'-0"1THIRD LEVEL DIMENSION PLAN
PA2021-013
BRANDON ARCHITECTS
DATE
A-3.0
PROJECT CONTACT
JEFF VAN VOORHIS, AIA
PROJECT NAME
PROJECT ADDRESS
908 W. OCEANFRONT
NEWPORT BEACH, CA 92661
OWNER INFORMATION
908 NB PROPERTY MANAGEMENT LLC
3717 EUCLID AVE.
DALLAS, TX
PROJECT STATUS
CDP
PLAN CHECK NO.
TBD
REVISIONS
NO.
DATE
1/27/2021 HARVEY RESIDENCEROOF PLAN
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
REVISIONS
These documents are the property of BRANDON
ARCHITECTS INC., and are not to be duplicated,
altered or utilized in any ay by any other party
without the expressed authorization of
BRANDON ARCHITECTS. Any unauthorized
duplication or alteration of these documents by
any party is a violation of BRANDON
ARCHITECTS expressed common law copyright
and other property rights thereto, and is subject
to full civil liabilities and penalties. These plans
are also not to be assigned to any third party
without obtaining written authorization and
expressed permission by BRANDON
ARCHITECTS, who shall then be held harmless
and absolved of any liability regarding any use
of these documents by such third party whether
depicted or implied hereon.A GENERAL NOTES
B KEYNOTES
DIMENSION NOTE:
ALL DIMS. ARE TO FACE OF STUD (F.O.S.) OR FACE OF SHT'G. (F.O.S.) TYP. U.N.O. EAVE DIMS. ARE FROM FACE OF SHT'G. TO FACE OF
FINISH FASCIA
ENLOSED ATTIC AND ENCLOSED RAFTER SPACES VENTING NOTES:
1. ENCLOSED ATTIC AND ENCLOSED RAFTER SPACES SHALL HAVE CROSS VENTILATION BY VENTILATION OPENING PROTECTED AGAINST
THE ENTRANCE OF RAIN OR SNOW UNLESS THEY MEET THE REQUIREMENT OF SECTION R806.5 FOR UNVENTED ATTIC AND
UNVENTED ENCLOSED RAFTER ASSEMBLIES. VENTILATION OPENING SHALL HAVE THE LEAST DIMENSION OF 1/16” MIN. AND 1/4”
MAX OTHERWISE THE OPENING SHALL HAVE THE CORROSION-RESISTANT WIRE CLOTH SCREENING, HARDWARE CLOTH, PERFORATED
VINYL OR SIMILAR MATERIAL WITH OPENINGS HAVE A LEAST DIMENSION OF 1/16” MIN. AND 1/4” MAX. OPENING IN ROOF FRAMING
MEMBERS SHALL BE PER THE REQUIREMENT OF SECTION R802.7. REQUIRED VENTILATION OPENINGS SHALL OPEN DIRECTLY TO THE
OUTSIDE AIR AND SHALL BE PROTECTED TO PREVENT THE ENTRY OF BIRDS, RODENTS, SNAKES AND OTHER SIMILAR CREATURES.
(R806.1)
2. THE MINIMUM NET FREE VENTILATING AREA SHOULD BE 1/150 OF THE AREA OF THE VENTED SPACE, EXCEPT FOR THE PROJECT
LOCATED IN CLIMATE ZONE 14 OR 16 WITH A CLASS I OR II VAPOR RETARDER AT THE WARM-IN-WINTER SIDE OF THE CEILING AND
WHERE MIN. 40% AND MAX 50% OF THE REQUIRED VENTILATION PROVIDED IN THE UPPER PORTION OF THE ATTIC OR RAFTER SPACE
PER SECTION R806.2 THEN THE MINIMUM NET FREE VENTILATING AREA CAN BE 1/300 OF THE VENTED SPACE. (R802.2)
3. PROVIDE 1” SPACE BETWEEN THE INSULATION AND THE ROOF SHEATHING WHERE EAVE OR CORNICE VENTS PROVIDE BLOCKING,
BRIDGING AND INSULATION SHALL NOT BLOCK THE FREE FLOW OF AIR. (R806.3)
4. INSTALL VENTILATOR PER MANUFACTURER INSTRUCTION. INSTALL VENTILATOR IN ROOF PER SECTION R903 AND VENTILATOR IN
WALL ASSEMBLIES PER SECTION R703.1.
5. FOR THE ATTIC WITH VERTICAL HEIGHT GREATER THAN OR EQUAL TO 30” (VERTICAL HEIGHT MEASURED FROM THE TOP OF CEILING
JOIST TO THE BOTTOM OF THE ROOF RAFTERS) WITHIN 30S.F. MIN. PROVIDE THE OPENING WITH ROUGH-FRAMED OPENING OF NOT
LESS THAN 22”X30” WHICH SHOULD BE LOCATED IN HALLWAY OR OTHER LOCATION WITH READY ACCESS. IF THE ACCESS LOCATED
IN THE WALL THEN THE WIDTH SHOULD BE 22” AND HEIGHT SHOULD BE 30” MIN. IF LOCATED IN CEILING THEN THE MIN.
UNOBSTRUCTED HEADROOM IN THE ATTIC SHOULD BE 30” FROM THE BOTTOM OF CEILING JOIST AT SOME POINT.
ROOF DRAINAGE:
IF THE PROJECT LOCATED IN THE AREA WITH EXPANSIVE OR COLLAPSIBLE SOILS, WATER RUNOFF FROM ROOFS OF ALL DWELLINGS
SHALL BE DISCHARGED TO THE GROUND SURFACE NOT LESS THAN 5 FEET FROM FOUNDATION WALLS OR TO AN APPROVED DRAINAGE
SYSTEM. (R801.3) - REF.CIVIL DWGS FOR STORM WATER MANAGMENT AND SYSTEM.
WEATHER PROTECTION:
1. ROOF DECKS SHALL BE COVERED WITH APPROVED ROOF COVERINGS SECURED TO THE BUILDING OR STRUCTURE IN ACCORDANCE
WITH THE CHAPTER 9 OF THE CURRENT CRC. ROOF ASSEMBLIES SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH THE
CHAPTER 9 OF CRC AND THE APPROVED MANUFACTURER’S INSTRUCTIONS SUCH THAT THE ROOF ASSEMBLY SHALL SERVE TO
PROTECT THE BUILDING OR STRUCTURE. (R903.1)
2. PROVIDE AND INSTALL FLASHING TO PREVENT ENTRY OF MOISTURE TO WALL AND ROOF ASSEMBLIES THRU THE JOINTS IN COPINGS,
PERMEABLE MATERIAL, AND AT INTERSECTION WITH PARAPET WALLS AND OTHER PENETRATION THRU ROOF. (R903.2)
3. FLASHINGS SHALL BE INSTALLED AT WALL AND ROOF INTERSECTIONS, WHEREVER THERE IS A CHANGE IN ROOF SLOPE OR
DIRECTION AND AROUND ROOF OPENINGS. A FLASHING SHALL BE INSTALLED TO DIVERT THE WATER AWAY FROM WHERE THE EAVE
OF A SLOPED ROOF INTERSECTS A VERTICAL SIDEWALL. WHERE FLASHING IS OF METAL, THE METAL SHALL BE CORROSION
RESISTANT WITH A THICKNESS OF NOT LESS THAN 0.019 INCH (0.5 MM) (NO. 26 GALVANIZED SHEET). (R903.2.1)
4. A CRICKET OR SADDLE SHALL BE INSTALLED ON THE RIDGE SIDE OF ANY CHIMNEY OR PENETRATION MORE THAN 30 INCHES (762
MM) WIDE AS MEASURED PERPENDICULAR TO THE SLOPE. CRICKET OR SADDLE COVERINGS SHALL BE SHEET METAL OR OF THE
SAME MATERIAL AS THE ROOF COVERING. EXCEPT FOR UNIT SKYLIGHTS INSTALLED IN ACCORDANCE WITH HYPERLINK
"HTTPS://CODES.ICCSAFE.ORG/LOOKUP/CRC2019P1_PT03_CH03_SECR308.6" SECTION R308.6 AND FLASHED IN ACCORDANCE
WITH THE MANUFACTURER’S INSTRUCTIONS SHALL BE PERMITTED TO BE INSTALLED WITHOUT A CRICKET OR SADDLE. (R903.2)
5. PARAPET WALLS SHALL BE PROPERLY COPED WITH NONCOMBUSTIBLE, WEATHERPROOF MATERIALS OF A WIDTH NOT LESS THAN
THE THICKNESS OF THE PARAPET WALL. (R903.3)
6. UNLESS ROOFS ARE SLOPED TO DRAIN OVER ROOF EDGES, ROOF DRAINS SHALL BE INSTALLED AT EACH LOW POINT OF THE ROOF.
IF WATER CAN BE ENTRAPPED WITHIN THE ROOF AREA THEN SECONDARY EMERGENCY OVERFLOW ROOF DRAINS OR SCUPPERS
SHALL BE PROVIDED PER SECTION R903.4.1. (R903.4)
2
A-5.0
2
A-5.0
4
A-5.0
4
A-5.0
6
A-5.1
6
A-5.1
7
A-5.2
7
A-5.2
3
A-5.1
3
A-5.1
2
A-5.0
2
A-5.0
5
A-5.1
5
A-5.1
1
A-4.0
2
A-4.0
4
A-4.0
3
A-4.03'-0"S.Y.S.B.3'-0"S.Y.S.B.8'-0"
F.Y.S.B.5'-0"3'-10"8'-1"15'-0 1/4"33'-5 1/8"
44'-9"5'-3 3/4"40.30' HT. CERT. REQ'D.40.30' HT. CERT. REQ'D.40.08' HT. CERT. REQ'D.40.30'HT. CERT. REQ'D.38.38' HT. CERT. REQ'D.38.38' HT. CERT. REQ'D.40.36' HT. CERT. REQ'D.3:123:123:123:123:123:123:123:1201.01
01.01
01.01
01.01
01.02
01.04
01.04
09.28
09.28
09.28
09.28
05.01
05.01
05.01
OPEN TO BLW.
OPEN TO BLW.
OPEN TO BLW.
OPEN TO BLW.
KEYNOTES
GENERAL NOTES
01.01 PROPERTY LINE
01.02 FRONT YARD SETBACK
01.04 SIDE YARD SETBACK
METALS
05.01 EXPOSED STEEL BEAM
SIZE PER STRUCT. DWGS., PAINT AND SEAL AS REQ'D.
FINISHES
09.28 STANDING SEAM METAL ROOFING
REF. MAT. SCHEDULE SHT. A-4.0
SCALE: 1/4" = 1'-0"1ARCHITECTURAL ROOF PLAN
PA2021-013
BRANDON ARCHITECTS
DATE
A-4.0
PROJECT CONTACT
JEFF VAN VOORHIS, AIA
PROJECT NAME
PROJECT ADDRESS
908 W. OCEANFRONT
NEWPORT BEACH, CA 92661
OWNER INFORMATION
908 NB PROPERTY MANAGEMENT LLC
3717 EUCLID AVE.
DALLAS, TX
PROJECT STATUS
CDP
PLAN CHECK NO.
TBD
REVISIONS
NO.
DATE
1/27/2021 HARVEY RESIDENCEEXTERIOR
ELEVATIONS
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
REVISIONS
These documents are the property of BRANDON
ARCHITECTS INC., and are not to be duplicated,
altered or utilized in any ay by any other party
without the expressed authorization of
BRANDON ARCHITECTS. Any unauthorized
duplication or alteration of these documents by
any party is a violation of BRANDON
ARCHITECTS expressed common law copyright
and other property rights thereto, and is subject
to full civil liabilities and penalties. These plans
are also not to be assigned to any third party
without obtaining written authorization and
expressed permission by BRANDON
ARCHITECTS, who shall then be held harmless
and absolved of any liability regarding any use
of these documents by such third party whether
depicted or implied hereon.
C KEYNOTES
A MATERIAL SPECIFICATIONS
B GENERAL NOTES
WINDOWS & DOORS:
AUTHORIZED DEALER (PRODUCTS LISTED BELOW)
SUPPLIER: ASSOCIATED BUILDING SUPPLY
ADDRESS: STONE MILL DESIGN CENTER 2915 RED HILL AVE., SUITE F104, COSTA MESA, CA 92626
CONTACT: JOE YOUNAN
PHONE: 949-872-3319
FAX: 206-666-2150
EMAIL: JYOUNAN@ABSSOCAL.COM
WEB: WWW.ASSOCIATEDBUILDINGSUPPLY.COM
ALUMINUM CLAD WINDOWS & PATIO DOORS
MANUFACTURER: JELD-WEN WINDOWS & DOORS
PRODUCT: CUSTOM COLLECTION
ADDRESS: 3250 LAKEPORT BLVD. P.O. BOX 1329; KLAMATH FALLS, OREGON 97601
PHONE: 541-885-7412 OR 800-535-3936
FAX: 541-884-3331
WEB: WWW.JELD-WEN.COM
MULTI SLIDE DOORS & STOREFRONT
MANUFACTURER: WESTERN WINDOW SYSTEMS
PRODUCT: SERIES 600 & STOREFRONT SYSTEMS
ADDRESS: 5621 S. 25TH ST., PHOENIX, AZ 85040
PHONE: 877.268.1300
WEB: WWW.WESTERNWINDOWSYSTEMS.COM
EXTERIOR STUCCO:
MANUFACTURER: MERLEX STUCCO
2911 ORANGE-OLIVE ROAD
ORANGE, CA 92865
P: 714.627.1700
COLOR: WHITE, ARCH. TO APPV.
APPLICATION: THREE-COAT APPL., SMOOTH 7/8" W/. METAL LATH (DIAMOND OR EQUIV.)
WOOD (EAVES):
SUPPLIER: TBD
TYPE: CLEAR-HEART HARDWOOD, CEDAR, OAK OR AS SEL. ARCH & CLIENT TO APPV.
SIZE:
TYPICAL EAVES: 1X6 T&G (TYP. EAVES)
MASTER BEDROOM EAVES: 2X4 MIXED WITH 1X6 PANELS
FINISH: CLEAR SEALANT, SEMI-GLOSS, CORD. W/. ARCH.
APPLICATION:
TYPICAL EAVEAS: T&G W/. SIMPLE REVEAL (COORD. WITH ARCH.) - SCORE & BACKPRIME
MASTER BEDROOM EAVES: 2X4 PIECES SPACED AT 3 1/2" O.C., 1X PANELS IN BEWEEN. (REF. DETLS,
ARCH. TO APPV. LAYOUT)
EXTERIOR STONE VENEER:
MANUFACTURER: TBD
STONE TYPE: STACKED LIMESTONE
COLOR: CREAM/OFF-WHITE, ARCH. TO APPV.
APPLICATION: TIGHT FITTING, APPX. 4" X 36" TILES (ARCH TO APPV. G.C. TO PROVIDE SAMPLE & MOCK-UPS)
THICKNESS: 1" -1.5" NOMINAL
WEIGHT: LESS THAN 15 LBS. / S.F.
METAL PANELS (FASCIA AND SIDING):
MANUFACTURER: TBD
COLOR: DK. GREY TO MATCH ROOF COLOR. ARCH. TO APPV.
FINISH: KYNAR PAINTED ALUM. ACM PANEL - ARCH. TO APPV. SIZING
ROOFING:
PRODUCT: STANDING SEAM METAL - KYNAR FINISH
MFGR: CUSTOM-BILT METALS
13940 MAGNOLIA AVE.
CHINO, CA. 91710
P: 909.664.1500
COLOR: GRAY - TO BE APPROVED BY ARCH. & OWNER
APPLICATION: USE CONTINUOUS 16" OR 18" PANS - VERIFY W/. ARCH. SIZE & LOC'N. OF
SEAMS. (NO TRANSVERSE SEAMS)
CODE: ESR-2048
WEIGHT: APPX. 2 PSF.
GUTTERS:
MATERIAL: METAL - ALUM. PAINTED KYNAR
SHAPE: SQUARE (5") (VERIFY W/. ARCH.)
GARAGE DOORS:
SUPPLIER: RANCH HOUSE DOORS
WEB: WWW.RANCHHOUSEDOORS.COM
STYLE: CUSTOM
MATERIAL: CUSTOM BUILT, WOOD & GLASS
WATERPROOF DECK MEMBRANE:
MFGR: TUFFLEX POLYMERS
ADDRESS: 10880 POPLAR AVE., FONTANA, CA
PHONE: 909.349.2016
WEB: WWW.TUFFLEXPOLYMERS.COM
CODE: ICC # ESR-2505
FLASHING & WEATHERSTRIPPING
PROVIDE MIN. 24 GUAGE METAL (16 OZ.) SHEETING (TO MATCH) FOR ALL EXTERIOR FLASHING & WEATHERSTRIPPING
APPLICATIONS. VERIFY W/. ARCHITECT ANY UNCONVENTIONAL ENVELOPE WATERPROOFING AREAS PRIOR TO INSTALLATION.
1. FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT LABELS.
2. REF. ROOF PLAN (A-3) FOR ALL PLATE HTS. & RIDGE HTS.
12 3 123123 12 3 12 3
123 123
10.30'
GARAGE T.O.C.
10.30'
GARAGE T.O.C.
11.80'
FIRST FLOOR F.F.
11.80'
FIRST FLOOR F.F.
22.30'
SECOND FLOOR F.F.
22.30'
SECOND FLOOR F.F.
31.47'
THIRD FLOOR F.F.
31.47'
THIRD FLOOR F.F.
38.38'
ROOF PLATE
38.38'
ROOF PLATE
11.36' GRADE PLANE
35.36' MAX. FLAT
40.36' MAX. HEIGHT
1'-6"10'-6"9'-2"6'-11"40.36' HT. CERT. REQ'D.
25.38' T.R.42" MIN.ABV. F.F.24'-0"29'-0"09.15
05.07
10.01
10.13
09.15
05.07
10.01
10.01
05.02
05.01
05.0209.09 09.09
10.14
6
12
30
PLPL
121
10.30'
GARAGE T.O.C.
10.30'
GARAGE T.O.C.
11.80'
FIRST FLOOR F.F.
11.80'
FIRST FLOOR F.F.
22.30'
SECOND FLOOR F.F.
22.30'
SECOND FLOOR F.F.
31.47'
THIRD FLOOR F.F.
31.47'
THIRD FLOOR F.F.
38.38'
ROOF PLATE
38.38'
ROOF PLATE
40.30'40.30'
35.36' T.R.
31.97'
32.69'
34.80'42" MIN.ABV. F.F.42" MIN.ABV. F.F.35.36' MAX. FLAT
40.36' MAX. RIDGE
11.36' GRADE PLANE24'-0"29'-0"09.15
09.15
09.09
09.09
09.09
09.09
05.05
05.06
05.06
05.06
05.02
10.01
10.13
09.09
09.28
09.28
05.07
10.14
6
1
4
24
9 810
25
26
22
3
7
23
PL
12 3123
12 3123 123 123
121 12 1
10.30'
GARAGE T.O.C.
10.30'
GARAGE T.O.C.
11.80'
FIRST FLOOR F.F.
11.80'
FIRST FLOOR F.F.
22.30'
SECOND FLOOR F.F.
22.30'
SECOND FLOOR F.F.
31.47'
THIRD FLOOR F.F.
31.47'
THIRD FLOOR F.F.
38.38'
ROOF PLATE
38.38'
ROOF PLATE
1'-6"10'-6"9'-2"6'-11"40.36' HT. CERT. REQ'D.
32.69'32.69'
2
1112
3
PLPL
12 1
10.30'
GARAGE T.O.C.
10.30'
GARAGE T.O.C.
11.80'
FIRST FLOOR F.F.
11.80'
FIRST FLOOR F.F.
22.30'
SECOND FLOOR F.F.
22.30'
SECOND FLOOR F.F.
31.47'
THIRD FLOOR F.F.
31.47'
THIRD FLOOR F.F.
38.38'
ROOF PLATE
38.38'
ROOF PLATE
1'-6"10'-6"9'-2"6'-11"11.36' GRADE PLANE
35.36' MAX FLAT.
40.36' MAX. HEIGHT40.30' HT. CERT. REQ'D.
35.36' T.R.HT. CERT. REQ'D.
31.97'
40.30' HT. CERT. REQ'D.
34.09'
32.69'
34.80'
40.36' HT. CERT. REQ'D.
25.38' T.R.42" MIN.ABV. F.F.42" MIN.ABV. F.F.42" MIN.ABV. F.F.24'-0"29'-0"09.09
09.0909.15
09.15
09.09
09.28
10.13
05.07
10.01
05.01
05.02
05.06
09.09
05.06
09.28
05.06
10.14
4
1920
5
5
17 1618 15
28 27
21
PLPL
KEYNOTES
METALS
05.01 EXPOSED STEEL BEAM
SIZE PER STRUCT. DWGS., PAINT AND SEAL AS REQ'D.
05.02 EXPOSED STEEL COLUMN
SIZE PER STRUCT. DWGS., PAINT AND SEAL AS REQ'D.
05.05 ACM PANEL SIDING
REF. MAT. SCHEDULE. ARCH. TO APPV. JOINT AND SEAM LAYOUT
05.06 ACM PANEL FASCIA
REF. MAT. SCHEDULE. ARCH. TO APPV. JOINT AND SEAM LAYOUT
05.07 SLANTED ACM PANEL FASCIA
REF. DETAILS AND MAT. SCHEDULE. ARCH. TO APPV. JOINT AND SEAM LAYOUT
FINISHES
09.09 STUCCO FINISH
MIN. 7/8" THK. W/. DIA. LATH, COLOR AS SEL., REF. MAT. SCHEDULE A-4.0
09.15 STONE VENEER
REF. MAT. SCHEDULE SHT. A-4.0
09.28 STANDING SEAM METAL ROOFING
REF. MAT. SCHEDULE SHT. A-4.0
SPECIALTIES
10.01 EXTERIOR GLASS GUARDRAIL
TEMPERED & LAMINATED - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
10.13 CUSTOM RAILING STAND OFF CAP
10.14 TEMPERED GLASS WINDOW WALL
REF. WINDOW WALL SCHEDULE A-7.0
SCALE: 1/4" = 1'-0"2SOUTH ELEVATION
SCALE: 1/4" = 1'-0"4WEST ELEVATION
SCALE: 1/4" = 1'-0"3NORTH ELEVATION
SCALE: 1/4" = 1'-0"1EAST ELEVATION
PA2021-013
PAD SCHEDULE
2'-0" SQ. X 24" DEEP PAD W(4)- # 5 E.W. @ BOTTOMP1
2'-6" SQ. X 24" DEEP PAD W(5)- # 5 E.W. @ BOTTOMP2
3'-0" SQ. X 24" DEEP PAD W(6)- # 5 E.W. @ BOTTOMP3
3'-6" SQ. X 24" DEEP PAD W(6)- # 5 E.W. @ BOTTOMP4
4'-0" SQ. X 24" DEEP PAD W(7)- # 5 E.W. @ TOP & BOTTOMP5
4'-6" SQ. X 24" DEEP PAD W(8)- # 5 E.W. @ TOP & BOTTOMP6
5'-0" SQ. X 24" DEEP PAD W(6)- # 6 E.W. @ TOP & BOTTOMP7
6'-0" SQ. X 24" DEEP PAD W(8)- # 6 E.W. @ TOP & BOTTOMP8
7'-0" SQ. X 24" DEEP PAD W(9)- # 6 E.W. @ TOP & BOTTOMP9
3'-6" WIDE X 5'-0" LONG X 24" DEEP PAD W/ #5 @ 8" O.C. E.W. TOP & BOTTOMP10
6'-0" WIDE X 8'-0" LONG X 24" DEEP PAD W/ #5 @ 8" O.C. E.W. TOP & BOTTOMP11
List of work requiring
special inspection:
SOILS COMPLIANCE PRIOR TO FOUNDATION INSPECTION
STRUCTURAL CONCRETE OVER 2500 psi
EXPANSION/ EPOXY ANCHORS
STRUCTURAL SHEAR WALLS TYPE NUMBER 2, 3, AND 4.
X
X
X
X
FIELD WELDINGX
HIGH STRENGTH BOLTS (A325)X
ANCHOR BOLT SCHEDULE
5/8" DIAMTETER X 12" ANCHOR BOLTS @ 32" O.C.32
5/8" DIAMTETER X 12" ANCHOR BOLTS @ 16" O.C.16
5/8" DIAMTETER X 12" ANCHOR BOLTS @ 8" O.C.8
3/4" DIAMTETER X 12" ANCHOR BOLTS @ 8" O.C. (MIN 3
A.B.'S)8*
FOUNDATION NOTES
1. ALL CONTINUOUS EXTERIOR FOOTINGS SHALL HAVE 5/8" DIAMETER X 12" A.B.'S
WITH 3" X 3" X 1/4" WASHERS, MIN.7" EMBEDMENT ONTO CONCRETE, AT 48" O.C.
UNLESS NOTED OTHERWISE ON PLANS. ONE ANCHOR BOLT SHOULD BE LOCATED
MAX. 12" AWAY FROM THE END OF THE SILL PLATE. MIN (2) A.B.'S PER SILL PLATE
PER SHEAR PANEL.
2. ALL INTERIOR WALLS SHALL HAVE HILTI-XU 7/32"Ø X 3 1/2" @ 32" O.C. TO BE
INSTALLED WITH ICC NUMBER 2269. ACTUAL SLAB THICKNESS SHALL BE
MINIMUM 3-1/2"
3. ALL HOLDOWNS AND POST ANCHORS SHALL BE INSTALLED ACCORDING TO SIMPSON
STRONG TIE SPECIFICATIONS AND REQUIREMENTS OF ICC REPORT # 2330
AND SHALL BE TIED IN PLACE PRIOR TO FOUNDATION INSPECTION.
4. MIN. CONCRETE WIDTH SHALL BE 8" FOR RECEIVING MPAs. AND HPAHD22s. VERIFY
LOCATIONS OF HOLDOWNS AND ANCHOR BOLTS WITH ROUGH FRAMING TO ASSURE
PROPER AND ACCURATE INSTALLATION.
5. PROVIDE #3X24" DOWEL AT 24" O.C. AND 12" FROM THE CORNER AT ALL CONCRETE
STOOP AND PORCHES.
6. PROVIDE MINIMUM (2) #5 REINFORCING BAR AT TOP AND (2) #5 AT BOTTOM FOR ALL
CONTINUOUS FOOTING IN ADDITION (1) #4 BAR EXTRA FOR ELECTRICAL GROUND.
LOCATION TO BE VERIFIED WITH ELECTRICAL CONTRACTOR.
7. VERIFY MINIMUM FOUNDATION DEPTH, WIDTH,REINFORCING STEEL AND ADDITIONAL
EXPANSIVE SOIL REQUIREMENTS WITH VALID SOILS REPORT AND IF ANY MORE
RESTRICTIVE THE SHALL SUPERSEDE THE ABOVE MINIMUMS.
8. CONCRETE STRENGTH SHALL BE MINIMUM 4,000 PSI, WATER CEMENT RATIO OF .5 AND
TYPE II CEMENT.
9. FOUNDATION DRAWING SHALL REFLECT THE STRUCTURAL REQUIREMENT ONLY.
REFER TO ARCHITECTURAL PLANS FOR DIMENSIONS NOT SHOWN.
ACCURACY OF THE DIMENSIONS AND FINAL FIT OF THE BUILDING SHALL BE
REVIEWED BY THE ARCHITECT AND THE CONTRACTOR PRIOR TO CONSTRUCTION.
10. WAITING PERIOD FOR CONCRETE SLAB-ON-GRADE PRIOR TO START OF
CONSTRUCTION IS AS FOLLOWS:
a. WALK ON SLAB 24 HOURS AFTER CONCRETE HAS BEEN POURED.
b. BEGIN WALL FRAMING 4-5 DAYS AFTER CONCRETE POUR.
c. BEGIN ROOF/FLOOR FRAMING 7-10 DAYS AFTER CONCRETE POUR.
d. DO NOT LOAD ROOF PRIOR TO 14 DAYS AFTER CONCRETE POUR.
11. THE MAXIMUM SOIL BEARING PRESSURE IS 1,500 PSF., PER SOILS REPORT #BA271.1
PREPARED BY: EGA CONSULTANTS, INC. DATED: 11/17/2020.
12. ALL DIMENSIONS SHOWN ON THE PLANS HAVE BEEN DETERMINED BY THE ARCHITECT
13. FASTNERS FOR PRESERVATIVE-TREATED SHALL BE HOT DIPPED ZINC-COATED
GALVANIZED STEEL, SILICON, BRONZE, OR COPPER.
14. SHEAR WALL ANCHOR BOLTS AND HOLDDOWN HARDWARE MUST
BE SECURED IN PLACE PRIOR TO FOUNDATION INSPECTION.
FOUNDATION LEGEND
EXTERIOR FOUNDATION
INTERIOR FOOTING
GRADE BEAM
HARDY FRAME NOTES:
HARDY FRAMES TO BE INSTALLED AT CENTER WIDTH OF GRADE BEAM
ALL REINFORCING STEEL AND TIES FOR HARDY FRAME TO
BE 60 KSI STEEL INCLUDING BARS #3,4,5,6HFX SPECIAL INSPECTION NOTE:
PER SECTION 1704.1.1,SPECIAL INSPECTION IS REQUIRED FOR HFX ANCHOR PLACEMENT
INCLUDING BOLT WASHER ASSEMBLY,EDGE DISTANCE AND END DISTANCE,SHEAR TIES
AND REINFORCING BARS
HFX STRUCTURAL OBSERVATION NOTE:
IN ACCORDANCE WITH DEPARTEMENT POLICY CBC 1710,STRUCTURAL OBSERVATION IS
REQUIRED FOR HFX ANCHOR PLACEMENT INCLUDING BOLT WASHER ASSEMBLY,EDGE
ISTANCE AND END DISTANCE,SHEAR TIES AND REINFORCING BARS
VERIFICATION AND INSPECTION
1. INSPECTION OF REINFORCING STEEL, INCLUDING PRESTRESSING TENDONS, AND PLACEMENT.
2. INSPECTION OF REINFORCING STEEL WELDING IN ACCORDANCE WITH TABLE 1705.2.2, ITEM 2B.
3. INSPECTION OF ANCHORS CAST IN CONCRETE WHERE ALLOWABLE LOADS HAVE BEEN INCRESED OR WHERE
STRENGTH DESIGN IS USED.
4. INSPECTION OF ANCHORS POST-INSTALLED IN HARDENED CONCRETE MEMBERS.
5. VERIFY USE OF REQUIRED DESIGN MIX.
6. AT THE TIME FRESH CONCRETE IS SAMPLED TO FABRICATE SPECIMENS FOR STRENGTH TESTS, PERFORM
SLUMP AND AIR CONTENT TESTS, AND DETERMINE THE TEMPERATURE OF THE CONCRETE.
7. INSPECTION OF CONCRETE AND SHOTCRETE PLACEMENT FOR PROPER APPLICATION TECHNIQUES.
8. INSPECTION FOR MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND TECHNIQUES.
9. INSPECTION OF PRESTRESSED CONCRETE:
A. APPLICATION OF PRESTRESSING FORCES.
B. GROUTING OF BONDED PRESTRESSING TEN-DONS IN THE SEISMIC FORCE-RESISTING SYSTEM.
10. ERECTION OF PRECAST CONCRETE MEMBERS
11. VERIFICATION OF IN-SITU CONCRETE STRENGTH, PRIOR TO STRESSING OF TENDONS IN POST-TENSIONED
CONCRETE AND PRIOR TO REMOVAL OF SHORES AND FORMS FROM BEAMS AND STRUCTURAL SLABS.
12. INSPECT FORMWORK FOR SHAPE, LOCATION AND DIMENSIONS OF THE CONCRETE MEMBER BEING FORMED.
TABLE 1705.3 REQUIRED VERIFICATION AND INSPECTION OF CONCRETE CONSTRUCTION
__
__
__
__
__
X
X
__
X
X
__
__
__
CONTINUOUS
X
__
X
X
X
__
__
X
__
X
X
X
PERIODIC REFERENCE
STANDARD
ACI 318: 3.5, 7.1-7.7
AWS D1.4
ACI 318: 3.5.2
ACI 318: 8.1.3,
21.2.8
ACI 318: 3.8.6, 8.3.6, 21.2.8ACI 318: CH. 4,
5.2-5.4
ASTMC 172
ASTMC 31
ACI 318: 5.6, 5.8
ACI 318: 5.9,
5.10ACI 318: 5.11-5.13
ACI 318: 18.20
ACI 318: 18.18.4
ACI 318: CH. 16
ACI 318: 6.2
ACI 318: 6.1.1
IBC
REFERENCE
1910.4
__
1908.5, 1909.1
1909.1
1904.2, 1910.2, 1910.3
1910.10
1910.6,
1910.7, 1910.8
19.10.9
__
__
__
__
LOUNGE
GREAT ROOM KITCHEN
PANTRY
DINING
ENTRY
STAIRS
PWDR.
ELEV.
SAND ROOM
3-CAR GARAGE
15" THK CONC. MAT SLAB
W/ #5 @ 12"O.C. EACH WAY TOP & BOTTOM
F'c = 4,000 PSI
OVER 2" SAND
OVER 15 MIL VAPOR BARRIER MEETING (ASTM 1745)
WITH ALL LAPS SEALED
OVER 4" THICK BASE OF 3/4" GRAVEL
1' - 6"
1' - 6"
1' - 6"1' - 6"9
D1
1
D1
1
D1
1
D1
1
D1
6
D1
11
D1
9
D11
D11
D1
1
D1
12D113
D1
10
D1
5
D1
TYP. @
NON-BR'G
WALL
76' - 11"33' - 11 1/2"2' - 0"2' - 0"24" WIDE X 24" DEEP GRADE
BEAM W/ (4) #5 TOP & BOTT. & #4
TIES @ 12" O.C., F'c = 4,000 PSI,
SPECIAL INSPECTION IS
REQUIRED.
P4P4P3
2
D1
1' - 6"P2P3
P3
P3
P4
P3
P4P5STEELCOL.P5
STEELCOL.STEELCOL.P5
P5
STEELCOL.
S T E E L
C O L .
11D1
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
12D1
15" THK CONC. MAT SLAB
W/ #5 @ 12"O.C. EACH WAY TOP & BOTTOM
F'c = 4,000 PSI
OVER 2" SAND
OVER 15 MIL VAPOR BARRIER MEETING (ASTM 1745)
WITH ALL LAPS SEALED
OVER 4" THICK BASE OF 3/4" GRAVEL
PROJECT DESCRIPTION:
1. THIS PROJECT IS A 3-STORY CUSTOM HOME TO BE BUILT USING MAINLY LIGHT FRAMED
WOOD CONSTRUCTION AND SOME STEEL MEMBERS AS REQUIRED PER FINAL DESIGN.
2. THE STRUCTURE TO BE BUILT ON MAT SLAB / GRADE BEAMS .
SHEET410 Goddard, Suite # 200Irvine, CA. 92618EMAIL: INFO@FMHENGINEERING.COMTel: 949-245-8000Cell: 310-422-1536OWNERPROJECT LOCATIONNew Custom Home
REVISIONS
1.
PROJECT
S-1FOUNDATION PLANHARVEY
RESIDENCE908 W. OCEANFRONT,NEWPORT BEACH, CA.908 W. OCEANFRONT,NEWPORT BEACH, CA.21-001HARVEY RESIDENCE01-12-2021
1/4" = 1'-0"1 S-1 - FOUNDATION PLAN
PA2021-013
SHEET
PROJECT
D-1
24
23
19
18
21
22 17
16
14
13
9
8
12
11 6
7
4
3
2
1
27
26
28
29
53010152025
21-001 NEWPORT BEACH., CA.HARVEY RESIDENCE908 W. OCEANFRONT,NEWPORT BEACH., CA.410 Goddard, Suite # 200Irvine, CA. 92618Tel: 949-245-8000Cell: 310-422-1536EMAIL: INFO@FMHENGINEERING.COMREVISIONSSHEET TITLEPROJECT LOCATIONFOUNDATION DETAILSPROJECT INFORMATIONPROJECT / TITLE
NEW CUSTOM
HOME
01-12-2021 908 W. OCEANFRONT,EXTERIOR BEARING WALL DETAIL
MAT SLAB PER PLAN
3"3"1'-6"
3"
CLR3"CLR2X STUD WALL
(2) #5 CONT. TOP & BOTT.
E.N.
F.G.
1:1 SEE PLANSLAB REINFORCEMENT
PER PLAN
A.B.'s @ 48" O.C. U.N.O ON PLANS.
W / 7" EMBEDMENT INTO FIRST POUR
2X OR 3X P.T.D.F. SILL PLATE
WITH 5/8" DIAMETERSHEAR
PER
PLAN
#24" MIN.#5 @ 12" O.C. W/ 48"
EMBEDMENT INTO SLAB
PER FOUNDATION PLANS
SLAB UNDERLAYMENT
SEE MINIMUM
FOUNDATION DEPTH
AT HOLDOWN PER
DETAIL 3,4&8/D1 4" MAX.(WHERE OCCURS)
INTERIOR BEARING WALL DETAIL
MAT SLAB PER PLAN
3"3"2:1
(2) #5CONT. BAR TOP. & BOTT.SEE PLAN1'-6"
2X STUD WALL
E.N.
SHEARPER
PLAN
#
2:1
#5 @ 12" O.C. W/ 48" EMBEDMENT
EACH SIDE INTO SLAB
MAT SLAB PER PLAN
3"3"3"3"2:1
(2) #5CONT. BAR TOP. & BOTT.
PER PLAN SEE PLAN1'-6"
2X STUD WALL
E.N.
SHEARPER
PLAN
#2X OR 3X P.T.D.F. SILL PLATE
WITH 5/8" DIAMETER A.B.'s @
48" O.C. U.N.O. ON PLANS. W/
7" EMBEDMENT INTO FIRST
POUR
2:1
#5 @ 12" O.C. W/ 48" EMBEDMENT
EACH SIDE INTO SLAB
SLAB REINF.
PER FOUNDATION PLANS
SLAB UNDERLAYMENT
COLD JOINT
SLAB
SSTB BOLT
ANCHOR TYPE
de
le5"
M
I
N
.
- REFER TO MFR. SPECS. FOR INSTALLATION TO WOOD MEMBER
21"
25"
1 3/4"
1 3/4"
HDU5
HDU8
4X4
4X4
5/8" SSTB24
ANCHOR DIA. AND TYPE
HOLDOWN
SIMPSON
(MIN.)
POST de le MIN DIST.
TO CORNER
- f'c = 2500 psi (U.N.O.)
- SEE PLANS FOR HOLDOWN TYPE
- DEEPEN FOOTING AS REQUIRED TO ACHIEVE le + 3" COVER
- REFER TO MFR. SPECS. FOR INSTALLATION TO WOOD MEMBER
- PROVIDE MIN. #4 BAR, 6'-0" LONG, 3" TO 5" FROM THE TOP OF
THE FOUNDATION. CENTERED AT "HD" OMIT IF BARS EXISTS AT THIS LOCATION
7/8" SSTB28
5"
5"
BASED ON WOOD CAPACITY
5645
6970
12" MIN112" MIN
ALLOWABLE TENSION LOADS(LBS)
25"1 3/4"HDU8 4X6 OR 7/8" SSTB28 5"7870
6X6 11 14"MAX.Le-11 1/4"+3" (COVER)
MIN.
TYP. HOLDOWN INSTALLATION
HDU14 6X6 1" DIA. PAB8 15"23"
THE FOUNDATION. CENTERED AT "HD" OMIT IF BARS EXISTS AT THIS LOCATION
- PROVIDE MIN. #4 BAR, 6'-0" LONG, 3" TO 5" FROM THE TOP OF
- REFER TO MFR. SPECS. FOR INSTALLATION TO WOOD MEMBER
- DEEPEN FOOTING AS REQUIRED TO ACHIEVE (De+ 3")
FOOTING
- SEE PLANS FOR HOLDOWN TYPE
- f'c = 2500 psi (U.N.O.)De1-3/4"
PAB
PER TABLE BELOW
SLAB
dePOST
(MIN.)
SIMPSON
HOLDOWN ANCHOR DIA. AND TYPE
1" DIA. PAB86X6HDU11
HOLDOWN
PER PLAN
F"F"
12"
F
18"
HD19 6X6 1 1/4" DIA. PAB10 16"24"
NON-BR'G WALL
SLAB REINFORCEMENT
PER PLAN
MAT SLAB PER PLAN
HILTI-XU (ICC NUMBER 2269)
7/32" DIA. X 3 1/2"
SHOT PINS @ 32" O.C.
2X P.T.D.F. PLATE WITH
PLACED 6" AND 10"
FROM PLATE ENDS.
AND FIRST 2 PINS
WITH 14 GAGE WASHERS
2X STUDS @ 16" O.C.
MAT SLAB PER PLAN
3"3"PER PLAN
3"
CLR3"CLR1:1 SEE PLANSLAB REINFORCEMENT
PER PLAN
EXTERIOR BEARING WALL DETAIL
#5 @ 12" O.C. W/ 48"
EMBEDMENT INTO SLAB
GRADE BEAM. REINFORCEMENT PER PLAN
PER FOUNDATION PLANS
SLAB UNDERLAYMENT4" MAX.24" MIN.#4 HOOKS @ 12" O.C.
POST PER PLAN
SILL PLATE
SLAB REINFORCEMENT
PER PLAN LeHOLDOWN PER PLAN
A307 STEEL ALLTHREAD PER TABLE
(2) #6 (48" LONG) EACH WAY
DIAGONAL & 3" SQ. X 1/4"
THK. PLATE WASHER @
HOLDOWN ALLTHREAD
HDU5
HDU8
5/8"Ø
HOLDOWN
SIMPSON ALLTHREAD(A307) Le
12"
12"7/8"Ø
MAT SLAB PER PLAN
3" SQ X 0.25" STEEL PLATE WASHER
BTWEEN (2) HEAVY HEX NUTS
MAT SLAB PER PLAN
MAX. UPLIFT
CAPACITY
HDU11 12"1"Ø
6000 LBS
8000 LBS
9500 LBS 8" MIN. TOSILL PLATE,10" MAX.TYP. HOLDOWN INSTALLATION
- REFER TO MFR. SPECS. FOR INSTALLATION TO WOOD MEMBER
21"1 3/4"HDU5 4X4 5/8" SSTB24
ANCHOR DIA. AND TYPE
HOLDOWN
SIMPSON
(MIN.)
POST de le MIN DIST.
TO CORNER
5"
BASED ON WOOD CAPACITY
5645
ALLOWABLE TENSION LOADS(LBS)
25"1 3/4"HDU8 4X6 OR 7/8" SSTB28 5"7870
6X6
MAT SLAB PER PLAN
3"3"1'-6"
3"
CLR3"CLR2X STUD WALL
REINFORCEMENT PER
E.N.8"MIN.F.G.
1:1 SEE PLANSLAB REINFORCEMENT
PER PLAN
SHEAR
PLAN #24" MIN.MAT SLAB REINFORCEMENT
PER DETAIL 1/D1
PER FOUNDATION PLANS
SLAB UNDERLAYMENT4" MAX.de
DETAIL 1/D1le
- f'c = 2500 psi (U.N.O.)
- SEE PLANS FOR HOLDOWN TYPE
- DEEPEN FOOTING AS REQUIRED TO ACHIEVE le + 3" COVER
- REFER TO MFR. SPECS. FOR INSTALLATION TO WOOD MEMBER
- PROVIDE MIN. #4 BAR, 6'-0" LONG, 3" TO 5" FROM THE TOP OF
THE FOUNDATION. CENTERED AT "HD" OMIT IF BARS EXISTS AT THIS LOCATION
24"1 3/4"HDU11 6X8 1" SB1X30 5"
24"1 3/4"HDU14 6X8 1" SB1X30 5"
11,175
14,445
POST CONNECTION DETAIL
MAT SLAB PER PLAN
3"3"1'-6"
3"
CLR3"CLR2X STUD WALL
(2) #5 CONT.
E.N.8"MIN.F.G.
1:1 SEE PLANSLAB REINFORCEMENT
PER PLAN
EXTERIOR GARAGE DETAIL
A.B.'s @ 48" O.C. U.N.O ON PLANS.
W / 7" EMBEDMENT INTO FIRST POUR
2X OR 3X P.T.D.F. SILL PLATE
WITH 5/8" DIAMETERSHEAR
PER
PLAN
#24" MIN.PERARCH#5 @ 12" O.C. W/ 48"
EMBEDMENT INTO SLAB
PER FOUNDATION PLANS
SLAB UNDERLAYMENT
SEE MINIMUM
FOUNDATION DEPTH
AT HOLDOWN PER
DETAIL 3 &4/D1 6" MIN.4" MAX.8"
(1) #5 CONT.3"A.B.'s @ 16" O.C. U.N.O.
3X P.T.D.F. SILL PLATE
WITH 5/8"Ø X 12"
2'-0" TYP.
#5 @ 12" O.C. E.W.
#5 @ 12" O.C.3" CLR.TYP.10" CONC. WALLELEVATOR PIT.12"PER MANUFACTURER2'-6" MAX.10" CONC. WALL
ELEVATOR PIT DETAIL
10"10"
MAT SLAB PER PLAN
3"3"1'-6"
3"
CLR
2X STUD WALL
(2) #5 CONT.
E.N.
1:1 SEE PLANSLAB REINFORCEMENT
PER PLAN
A.B.'s @ 48" O.C. U.N.O ON PLANS.
W / 7" EMBEDMENT INTO FIRST POUR
2X OR 3X P.T.D.F. SILL PLATE
WITH 5/8" DIAMETERSHEAR
PER
PLAN #PERARCHMAT SLAB PER PLAN
3"3"1:1SEE PLAN#5 @ 12" O.C. W/ 48"
EMBEDMENT INTO SLAB
48"
48"6" MIN.4" MAX.4" MAX.(WHERE OCCURS)
#5 @ 12" O.C. W/ 48"
EMBEDMENT INTO SLAB
SLAB REINFORCEMENT
PER PLAN
(2) #5 CONT.
OR HARDY FRAMEWHERE OCCURS
1'-6"
HOUSE TO GARAGE
(1) #5 CONT.
8"3"18" MAXSTEP AT CONCRETE SLAB
W/ 18" EMBEDMENT
FOR DBL POUR COND.
#5 DOWELS @ 24" O.C.
INTO EACH WAY
#5 CONTINUOUS BAR
#5 CONTINUOUS BAR
SLAB REINF. PER PLAN
MAT SLAB PER PLAN
3"3"1'-6"
3"
CLR3"CLR(2) #5 CONT.
1:1 SEE PLANSLAB REINFORCEMENT
PER PLAN
#5 @ 12" O.C. W/ 48" EMBEDMENT
INTO SLAB
EXTERIOR BEARING WALL DETAIL 4" MAX.3"
CLR
(TYP)
PER FOUNDATION PLANS
SLAB UNDERLAYMENT24" MIN.40 D OR24" MIN.40 D OR24" MIN.40 D OR
24" MIN.
ALTERNATE
CORNER PIECE (
BAR BENDS
OMITTED).
FOOTING
REINFORMENT.
FOUNDATION PER
PLANS
REINFORCING REBAR @ CORNERS
R
R 8(d)8(d)
°90 BEND °180 BENDBEND
4(d)
2 1/2" MIN.12dWIRE TIE END
48(d) * IN CONCRETE
48(d) MASONRY (U.N.O.)
LAP SPLICE
R = 3(d) FOR #3 THRU #8
R = 4(d) FOR #9 THRU #11
R = 5(d) FOR #12 THRU #18
TYP. REINFORCING DETAILS
* INCREASE LENGTH BY 30%
FOR TOP BARS (HORIZONTAL
BARS SO PLACED THAT MORE
THAN 12 INCHES OF FRESH
CONCRETE IS CAST IN THE
MEMBER BELOW, EXCLUDE
WALLS)
CLOSED TIE OR HOOP
STIRRUP DETAILINGDIMENSION4
"
M
IN
.
O
R
6(
d
)
M
I
N
.DETAILINGDIMENSION4" M
IN
.
OR
6
(
d
)
M
IN
.
CROSSTIE
D = 4(d) FOR #3 THRU #5
D = 6(d) FOR #6 THRU #8
NOTES:
- PUT CROSSTIE W/ EACH
STIRRUP ALT. 135 BENDS°
- ALL BENDS SHALL BE
MADE COLD
D D
12(d) FOR #6 THRU #86(d) FOR #5 & SMALLER> 3" MIN.6(d)> 3" MIN.PA2021-013