Loading...
HomeMy WebLinkAbout20171215_ZA Action LetterCommunity Development Department CITY OF NEWPORT BEACH 100 Civic Center Drive Newport Beach, California 92660 949 644-3200 newportbeachca.gov/communitydevelopment VIA EMAIL December 15, 2017 Kasey Clark AKC Permit Company Kelley Franchise, Inc. 15197 Lighthouse Lane Lake Elsinore, CA 92530-5674 951-471-8419 Office 951-609-5144 Cell Kaseyuc@akcservices.net Subject: 2119-2121 West Balboa Blvd. Comprehensive Sign Program Taco Bell Cantina and TK Burgers Comprehensive Sign Program No CS2017-015 (PA2017-226) Dear Ms. Clark, Please be advised that the subject application was approved by the Zoning Administrator on December 15, 2017 and is now within the required City appeal period until January 2, 2018. A copy of the approved action letter with findings and conditions of approval is attached. If you have any questions, please do not hesitate to contact me directly. Thank you and I look forward to working with you again in the future. Sincerely, 949-644-3219 gramirez@newportbeachca.gov Cc: Tatiana Belousov Everbrite – Greenfield, WI Sr. Program Manager TBelousov@EVERBRITE.COM COMMUNITY DEVELOPMENT DEPARTMENT PLANNING DIVISION 100 Civic Center Drive, P.O. Box 1768, Newport Beach, CA 92658-8915 949-644-3200 www.newportbeachca.gov ZONING ADMINISTRATOR ACTION LETTER Application No. Comprehensive Sign Program No. CS2017-015 (PA2017-226) Applicant AKC Services Inc Site Location 2119-2121 West Balboa Boulevard Taco Bell Cantina and TK Burgers Legal Description Lot 14 in Block 21 of Newport Beach, County of Orange On December 15, 2017 the Zoning Administrator approved Comprehensive Sign Program No. CS2017-015. This approval is based on the following findings and subject to the following conditions. Pursuant to NBMC Section 20.42.120, a Comprehensive Sign Program is required when new signs are proposed to be located on or above the second story of a multi-story building. Comprehensive sign programs can allow limited deviations from code requirements related to location and size under certain circumstances. This Sign Program includes two projecting signs and allows one to be located closer than five feet to an interior property line and one to be located less than five feet to a line dividing two separate business frontages. The sign program also allows a secondary frontage projecting sign to be 13 square feet where the code allows a maximum are of 10 square feet. The subject property is designated MU-W2 (Mixed-Use Water Related) by the General Plan Land Use Element, the Coastal Land Use Plan, and the Zoning Code. The Sign Program includes standards for three different sign types (not including address numbering) and a total of four signs. Two projecting (blade) signs, one combination wall/projecting sign and one wall sign for two restaurants located on a mixed-use building are included in the sign program. One projecting sign and one wall sign will face the McFadden municipal parking lot, one projecting sign will face 22nd Street and the combination sign will face the parking lot access drive and will be located over the entrance of the Taco Bell Cantina. The approval of this Sign Program is based on the following findings and standards and subject to the following conditions: Taco Bell Cantina/TK Burgers Comprehensive Sign Program December 15, 2017 Page 2 Tmplt: 04/01/16 Finding A. The project is exempt from environmental review under the requirements of the California Environmental Quality Act pursuant to Section 15311, Class 11 (Accessory Structures), because it has no potential to have a significant effect on the environment. Fact in Support of Finding 1. Class 11 exempts minor structures accessory to existing commercial facilities, including signs. The proposed signs are incidental and accessory to the principal commercial uses of the mixed-use building and do not intensify or alter the authorized principal use. All signs will be mounted in the building. Finding B. The proposed comprehensive sign program is consistent with Section 21.30.065 that regulates roof signs and free-standing signs and prohibits billboards. Fact in Support of Finding 1. Based upon the sign matrix and project plans, the Sign Program would not include pole or other freestanding signs, roof signs or billboards. Standard C. The proposed sign program shall comply with the purpose and intent of this Chapter [Chapter 20.42], any adopted sign design guidelines, and the overall purpose and intent of this Section [Section 20.42.120 – Comprehensive Sign Program]. Facts in Support of Standard 1. The purpose of NBMC Chapter 20.42 is to provide adequate identification of uses while guarding against excessive and confusing signage. The goal is to preserve and enhance community appearance by regulating the type, size, location, quantity, design, character, scale, color, illumination, and maintenance of signs. Regulations should encourage well-designed signs that attract and invite rather than demand the public’s attention. Signs need to be complementary to their related buildings and uses and need to be harmonious with their surroundings. Signs need to enhance the safety of motorists and pedestrians by minimizing the distraction of signs, as well as to protect the life, health, property, and general welfare of City residents and visitors. 2. The purpose of comprehensive sign programs is to integrate project signs with the overall site design and architecture to create a unified architectural design statement. A comprehensive sign program also provides a means for the flexible Taco Bell Cantina/TK Burgers Comprehensive Sign Program December 15, 2017 Page 3 Tmplt: 04/01/16 application of sign regulations for projects that require multiple signs. Comprehensive sign programs can also provide incentives and latitude in the design and display of multiple signs and to achieve, not circumvent, the purpose of NBMC Chapter 20.42. 3. The proposed Sign Program is consistent with the purpose and intent of the NBMC Chapter 20.42 because it is comprehensive by including all types of signs. It includes a limited number of quality signs at appropriate locations to identify the businesses. a. The 2121 West Balboa Boulevard tenant space is located at the corner of the building/lot and has two primary frontage and one small secondary frontage (over the business entrance). b. The projecting signs are located 0 (zero) feet from the adjacent tenant space (TK Burgers) adjacent to the McFadden parking lot and 0 (zero) feet from the adjacent property line on 22nd Street where the sign code requires a 5-foot setback. The projecting sign locations are designed to fit with the building architecture and be viewable from the McFadden Place parking lot, 22nd Street and the beachfront boardwalk at the end of 22nd Street. Both signs are 13 square feet where the code allows a maximum of 20 square feet on the primary frontage (McFadden place parking lot) and 10 square feet on the secondary frontage (22nd Street). A comprehensive sign program may allow 30% increase in sign area. In this particular case a 3 square foot increase in sign are for the secondary frontage will result in two signs of the same size (13 square feet), which provides for a unified and balanced design. The two projecting signs are located on the second floor of the mixed-use building at an elevation commensurate and complementary to the building architecture and setback form the street corner to provide architecturally balanced design and look. c. The combination wall/projecting sign is located at the corner of the building and centered above the entrance to Taco Bell Cantina. The sign type and size adequately identifies the business and location of the entrance for potential patrons. The sign size is 21.71 square feet, smaller than the 26 square feet allowed for the secondary frontage. The projecting feature of the sign provides adequate vertical clearance to allow pedestrian passage to the restaurant entrance. d. The wall sign located on the 2119 West Balboa Boulevard tenant space (TK Burgers) is 36.8 square feet, smaller than the allowed maximum of 39.75 square feet for a primary frontage. Future signage will be allowed the maximum 39.75 square feet. The sign is generally centered on the tenant frontage, located above the entrance to the business, and balanced with the architectural features of the building. Taco Bell Cantina/TK Burgers Comprehensive Sign Program December 15, 2017 Page 4 Tmplt: 04/01/16 Standard D. The proposed signs shall enhance the overall development, be in harmony with, and relate visually to other signs included in the Comprehensive Sign Program, to the structures and/or developments they identify, and to surrounding development when applicable. Facts in Support of Standard 1. All signs relate visually to each other and the building design because they maintain consistency in design, materials, and color while identifying the businesses in the building. 2. The proposed signs will not obstruct public views from adjacent roadways because there are no identified public views through or across the subject property. 3. The proposed signs will not interfere with sight distance from any street or driveway. Standard E. The sign program shall address all signs, including permanent, temporary, and exempt signs. Fact in Support of Standard The Sign Program addresses all project signage. Temporary and exempt signs not specifically addressed in the Sign Program shall be regulated by the provisions of Chapter 20.42 (Sign Standards) of the Zoning Code. Standard F. The sign program shall accommodate future revisions that may be required because of changes in use or tenants. Facts in Support of Standard 1. The Sign Program establishes allowed type, number, location, and area of signs with flexibility to accommodate existing and future tenants, activities, or uses. 2. It is not anticipated that future revisions to the Sign Program will be necessary to accommodate a change in tenant or use. However, the Community Development Director may approve minor revisions to the Comprehensive Sign Program if the intent of the original approval is not affected. Taco Bell Cantina/TK Burgers Comprehensive Sign Program December 15, 2017 Page 5 Tmplt: 04/01/16 Standard G. The program shall comply with the standards of this Chapter [Chapter 20.42], except that deviations are allowed with regard to sign area, total number, location, and/or height of signs to the extent that the Comprehensive Sign Program will enhance the overall development and will more fully accomplish the purposes and intent of this Chapter [Chapter 20.42]. Facts in Support of Standard 1. Facts in support of Finding C above regrading location and area of the projecting signs are incorporated by reference. 2. No other deviations from sign area, total number or height are authorized by this Sign Program. Standard H. The approval of a Comprehensive Sign Program shall not authorize the use of signs prohibited by this Chapter [Chapter 20.42]. Facts in Support of Standard The Sign Program does not authorize the use of any prohibited signs including changeable copy, pole, roof, animated, “A” frame signs or billboards. Standard I. Review and approval of a Comprehensive Sign Program shall not consider the signs’ proposed message content. Facts in Support of Standard 1. The Sign Program contains no regulations affecting sign message content. 2. The content of the signs as expressed in the conceptual plans was not considered during the review and approval of this Sign Program. CONDITIONS 1. All proposed signs shall be in substantial conformance with the Comprehensive Sign Program Matrix Table (Attachment No. ZA 2), approved plans (Attachment No. ZA 3) and provisions of Chapter 20.42 of the Newport Beach Municipal Code, unless otherwise indicated in the following conditions. 2. Signs not specifically approved by this Sign Program are prohibited. Taco Bell Cantina/TK Burgers Comprehensive Sign Program December 15, 2017 Page 6 Tmplt: 04/01/16 3. Any future revisions or changes to the signs approved by this Sign Program due to a change in the use or tenants of the building shall be reviewed and approved by the Planning Division, so long as the sign size, copy configuration, and number of signs authorized by this approval does not substantially change or increase. 4. A building permit and/or sign permit shall be obtained prior to the installation of signs. 5. A copy of this letter and the approved sign matrix shall be incorporated into the plan check sets of plans prior to issuance of building or sign permits. 6. Illuminated signs shall be regulated in accordance with the provisions of Section 20.42.060.H of the Newport Beach Municipal Code. If, in the opinion of the Community Development Director, existing illumination creates an unacceptable negative impact on surrounding land uses or sensitive habitat areas, the Director may order the dimming of light sources or other remediation including requiring to sign lighting to be turned off upon finding that the site is excessively illuminated. 7. All signs shall be maintained in a clean and orderly condition. Signs in disrepair shall be repaired, replaced or removed in a timely fashion or at the direction of the Community Development Director. 8. All work performed near or within the public right-of-way or City-administered public easement area shall be reviewed and approved by the Public Works Department. If any work is necessary within the public right-of-way or a City- administered public easement, an encroachment permit or encroachment agreement is required. 9. The Community Development Director may approve revisions to the Sign Program if the intent of the original approval is not affected. Revisions that would substantially deviate from the original approval shall require approval of a new/revised comprehensive sign program by the Zoning Administrator. 10. The Zoning Administrator, Planning Commission or City Council may add to or modify conditions of this approval, or revoke this approval upon a determination that any sign that is authorized by this approval has been altered beyond the parameters of the authorization and therefore beyond the justification. 11. This approval shall expire and become void unless exercised within twenty-four (24) months from the actual date of review authority approval, except where an extension of time is approved in compliance with the provisions of Title 20 Planning and Zoning, of the Newport Beach Municipal Code. 12. To the fullest extent permitted by law, applicant shall indemnify, defend and hold harmless City, its City Council, its boards and commissions, officials, officers, employees, and agents from and against any and all claims, demands, obligations, damages, actions, causes of action, suits, losses, judgments, fines, penalties, Taco Bell Cantina/TK Burgers Comprehensive Sign Program December 15, 2017 Page 7 Tmplt: 04/01/16 liabilities, costs and expenses (including without limitation, attorney’s fees, disbursements and court costs) of every kind and nature whatsoever which may arise from or in any manner relate (directly or indirectly) to City’s approval of the Taco Bell Cantina/TK Burgers Comprehensive Sign Program including, but not limited to, Comprehensive Sign Program No. CS2017-015 (PA2017-226). This indemnification shall include, but not be limited to, damages awarded against the City, if any, costs of suit, attorneys' fees, and other expenses incurred in connection with such claim, action, causes of action, suit or proceeding whether incurred by applicant, City, and/or the parties initiating or bringing such proceeding. The applicant shall indemnify the City for all of City's costs, attorneys' fees, and damages which City incurs in enforcing the indemnification provisions set forth in this condition. The applicant shall pay to the City upon demand any amount owed to the City pursuant to the indemnification requirements prescribed in this condition. APPEAL PERIOD: An appeal or call for review may be filed with the Director of Community Development within fourteen (14) days following the date the action. For additional information on filing an appeal, contact the Planning Division at 949 644-3200. On behalf of Patrick J. Alford, Zoning Administrator By: JC/gbr Attachments: ZA1Vicinity Map ZA2 Comprehensive Sign Program Matrix ZA3 Project Plans Attachment No. ZA 1 Vicinity Map Taco Bell Cantina/TK Burgers Comprehensive Sign Program December 15, 2017 Page 2 Tmplt: 04/01/16 VICINITY MAP Comprehensive Sign Program No. CS2017-015 PA2017-226 2119-2121 West Balboa Blvd Attachment No. ZA 2 Comprehensive Sign Program Matrix COMPREHENSIVE SIGN PROGRAM MATRIX 2119 AND 2121 WEST BALBOA BOULEVARD PA2017-226 Sign Type Address Primary Frontage & Size Limitation Secondary Frontage & Size Limitation Projecting (Blade)Sign 2121 West Balboa Blvd. Type: Projecting (Blade)Sign Frontage: McFadden Place Parking Lot Placement: Second Story Maximum Area: 13 square feet Letter /Logo Height: 18 inches Type: Projecting (Blade)Sign Frontage: 22nd Street Placement: Second Story Maximum Area: 13 square feet Letter /Logo Height: 18 inches Wall/ Projecting Combo Sign 2121 West Balboa Blvd. Type: Projecting/Wall Sign Frontage: McFadden Place Parking Lot –Over Restaurant Entrance Placement: First Story Maximum Area: 22 square feet Letter /Logo Height: 7 inches/30 inches Wall Sign 2119 West Balboa Blvd. Type: Wall Sign Frontage: McFadden Place Parking Lot Placement: First Story Maximum Area: 39.75 square feet Letter /Logo Height: 36 inches None NOTES/REQUIREMENTS a) Requirements for all signs per Municipal Code Chapter 20.42, except as provided in this sign matrix. b) Sign designs shall be consistent with Citywide Sign Design Guidelines Manual. c) Pursuant to Section 20.42.120.F of the Zoning Code, the Community Development Director may approve minor revisions to this approval if the intent of the original approval is not affected. Attachment No. ZA 3 Project Plans Attachment No. CD 5 Attachment Name ALL REPORTS, PLANS AND DOCUMENTS PREPARED BY MARKS ARCHITECTS SHALL REMAIN THE PROPERTY OF MARKS ARCHITECTS AND IS INTENDED FOR USE FOR THIS SPECIFIC PROJECT ONLY.LICEN SE D ARCH IT ECTBLDG. DEPT. SUBMITTAL 03.30.17 TACO BELL 2121 W. BALBOA BLVD. NEWPORT BEACH, CA 92663 CANTINA A0.1 SITE PLAN SITE PLAN A KEY NOTES B 1 2 EXISTING STREET PARKING EXISTING STREET TREES PROPOSED 1,288 SF TACO BELL RESTAURANT EXISTING RESTAURANT B OCCUPANCY B OCCUPANCY NOT A PART EXISTING RESTAURANT B OCCUPANCY NOT A PART 1 2 2 2 3 EXISTING STREET ACCESSIBLE PARKING. SHOWN FOR REFERENCE ONLY 3 NOTE: ELECTRICAL METERS ON SECOND FLOOR ROOF ACCESS FROM SECOND FLOOR 1ST FLOOR: 2,639 SF - B OCCUPANCY 2ND FLOOR: 2,639 SF - R2 OCCUPANCY EXISTING 2 STORY BUILDING VB CONSTRUCTION TOTAL AREA: 5,278 SF DEMOLITION PLAN 1'=10'-0"B ORIGINAL PIZZA OCCUPANT LOAD ANALYSIS KITCHEN AREA: DINING ROOM: RESTROOMS: 715 SF 592 SF 99 SF /200 /15 /0 = 3.57 = 39.46 = 0 TOTAL OCCUPANT LOAD:= 43.03 NUMBER OF SEATS = 62 HOURS OF OPERATION:11:00 AM TO 11:00 PM PREVIOUS TENANT NET PUBLIC AREA:= 691 SF DEMO ALL INTERIOR IMPROVEMENTS DEMO ALL DOORS AND WINDOWS TYPICAL TRASHTRASHACCESSIBLE PATH OF TRAVEL EXISTING ACCESSIBLE EXISTING PARKING SPACE PUBLIC WORKS NOTES 1.An approved encroachment permit is required for all work activities within the public right-of-way. 2.A Public Works Department encroachment permit inspection is required before the Building Department Permit Final can be issued. At the time of Public Works Department inspection, if any of the existing public improvements surrounding the site is damaged, new concrete sidewalk, curb and gutter, and alley/street pavement will be required. Additionally, if existing utilities infrastructure are deemed substandard, a new 1-inch water service, water meter box, sewer lateral and/or cleanout with box and lid will be required. 100% of the cost shall be borne by the property owner (Municipal Codes 14.24.020 and 14.08.030). Said determination and the extent of the repair work shall be made at the discretion of the Public Works Inspector. 3.Provide a backflow preventer at the water meter per City Standard #520-L if one does not exist. 4.Install a sewer cleanout per City Standard #406-L if one does not exist EXISTING 4" SANITARY SEWER LINE EXISTING FIRE HYDRANT 34'-101 2" 98'-10" DEMOLITION NORTH ELEVATION 1/4"=1'-0"A PROPOSED NORTH ELEVATION 1/4" = 1'-0"B 23'-2" T.O. PARAPET ALL REPORTS, PLANS AND DOCUMENTS PREPARED BY MARKS ARCHITECTS SHALL REMAIN THE PROPERTY OF MARKS ARCHITECTS AND IS INTENDED FOR USE FOR THIS SPECIFIC PROJECT ONLY. marks architects 2017 CUP FOR ABC SUBMITTAL 09.21.17 TACO BELL 2121 W. BALBOA BLVD. NEWPORT BEACH, CA 92663 CANTINASDOO TA EST RENEWAL DATE CF FLAI9-30-2019 NRAIR KINAC-26463 JLE. M A LICEN SE D ARCH IT ECTⒸ CUP FOR TYPE C41 ABC LICENSE A4.0 EXTERIOR ELEVATIONS DEMO DOOR DEMO SIGN1 2 3 4 5 DEMO FABRIC AWNING DEMO LIGHT AND EXPOSED CONDUIT DEMO WINDOW 1 1 1 1 22 2 2 33 4 4 0'-0" FIN. FLOOR 11'-6" FIN. FLOOR 5 6 DEMO PORTION OF WALL 6 23'-2" T.O. PARAPET 0'-0" FIN. FLOOR 11'-6" FIN. FLOOR 1 2 3 4 5 6 5 3 1 2 CONTINUOUS PARAPET CAP SYMBOL AREA MAIN WALL COLOR SHERWIN WILLIAMS MANUFACTURER SHERWIN WILLIAMS COLOR ACCENT & WINDOWS SHERWIN WILLIAMS SW7069 IRON ORE SHERWIN WILLIAMS SW7069 IRON OREACCENT WALL COLOR SW7069 IRON ORE 4 FIBER CEMENT PANELS JAMES HARDIE HARIDE PANEL PACER WHITE SW6098 NEW WALL SIGN UNDER A SEPARATE PERMIT INDICATES ROOF BEYOND NEW METAL COPING FIBER CEMENT PANEL OVER EXISTING WALL EXISTING AWNING, REPLACE FABRIC EXISTING MURAL, NO WORK INSTALL FACTORY OUTSIDE CORNER TO MATCH CEMENT BOARD PANEL 7 8 9 10 11 12 NEW EIFS TRIM. SEE DETAIL EXISTING TRIM, TYPICAL 13 NEW GLASS FOLDING WINDOW, SEE DOOR SCHEDULE 14 NEW WINDOW / STOREFRONT. SEE WINDOW SCHEDULE 15 16 17 18 NEW LIGHT FIXTURE, SEE ELECTRICAL PLANS 1 NEW MURAL BY OTHERS CANTINA 2 1 3 NEW ALUMINUM CANOPY WITH LETTERS BY VENDOR UNDER A SEPARATE PERMIT 4 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 6 6 6 7 7 9 9 999 10 10 10 10 11 14 3 14 3 14 3 14 3 14 3 14 3 14 3 14 3 14 3 11 11 11 14 3 14 3 14 3 14 3 14 3 15 1 1 1 1 1 1 1 11 1 3 1 1 4 5 5 5 5 5 5 5 5 5 5 5 NEW ALUMINUM STOREFRONT. SEE A1.1 18 18 DEMOLITION NOTES 6 CANOPIES SUNBRELLA ACRYLIC BLACK 6 6 6 C A4.0 MENU BOARD DETAIL NTS C 1" x 3 1/2" NICHITRIM - PAINT TO MATCH SIDING NICHIHA ARCHITECTURAL WALL PANELS OVER VAPOR BARRIER - SEE EXTERIOR ELEVATIONS - INSTALL PER MANUFACTURER RECOMMENDATIONS. NICHIHA STARTER TRACK PAINTED GALVANIZED BREAK METAL FLASHING (E) URM WALL WEATHER RESISTANT BARRIER METAL FURRING CHANNEL MENU BOARD 19 19 NEW MENU BOARD. SIZE TO BE DETERMINED BY TACO BELL. BACK LIT MENU BOARD REQUIRES POWER. 12 5 PASS-THRU WINDOW TO REMAIN 7 EXISTING PASS THRU WINDOW TO REMAIN 7 TIMBER BARK SHERWIN WILLIAMS PACER WHITE SHERWIN WILLIAMS IRON ORE JAMES HARDIE HARDIE PANEL COLOR: TIMBER BARK EXISTING CONCRETE WALL EXISTING TRIM 1-5/8" HARDIE TRIM HARDIE BOARD SAND AND CLEAN ALL EXISTING WINDOW FRAMES, PAINT PER SCHEDULE 39'-2" PATCH AND REPAIR EXISTING STUCCO PRIOR TO PAINTING WALL. NEW BUILDING" BLADE" SIGN - UNDER SEPARATE PERMIT 31'-1"2'-10"4'-6"8'-0" (E) TK BURGERS SIGN 36 SF 8' W x 4'-6" T 4'-0"1'-0" (E) ORIGINAL PIZZA AND COCA COLA SIGNS 69 SF TOTAL (E) ORIGINAL PIZZA 12" BLADE SIGN 16 SF TOTAL (E) ORIGINAL PIZZA SIGN 23.5 SF TOTAL 26'-6" TACO BELL CANTINA STORE FRONTTK BURGERS STORE FRONT DEMOLITION NORTH ELEVATION 1/4"=1'-0"A PROPOSED NORTH ELEVATION 1/4" = 1'-0"B ALL REPORTS, PLANS AND DOCUMENTS PREPARED BY MARKS ARCHITECTS SHALL REMAIN THE PROPERTY OF MARKS ARCHITECTS AND IS INTENDED FOR USE FOR THIS SPECIFIC PROJECT ONLY. marks architects 2017 CUP FOR ABC SUBMITTAL 09.21.17 TACO BELL 2121 W. BALBOA BLVD. NEWPORT BEACH, CA 92663 CANTINASDOO TA EST RENEWAL DATE CF FLAI9-30-2019 NRAIR KINAC-26463 JLE. M A LICEN SE D ARCH IT ECTⒸ CUP FOR TYPE C41 ABC LICENSE A4.1 EXTERIOR ELEVATIONS 23'-2" T.O. PARAPET 0'-0" FIN. FLOOR 11'-6" FIN. FLOOR 23'-2" T.O. PARAPET 0'-0" FIN. FLOOR 11'-6" FIN. FLOOR 23'-2" T.O. PARAPET 0'-0" FIN. FLOOR 11'-6" FIN. FLOOR 23'-2" T.O. PARAPET 0'-0" FIN. FLOOR 11'-6" FIN. FLOOR CANTINA 1 2 3 7 4 6 6 14 3 5 5 14 3 14 3 14 3 16 17 18 18 1013101 9'-0" STOREFRONT 10 1 9 1 9 1 5 74 CANTINA 2 1 3 7 4 18 1 2 3 4 5 6 5 3 1 2 CONTINUOUS PARAPET CAP SYMBOL AREA MAIN WALL COLOR SHERWIN WILLIAMS MANUFACTURER SHERWIN WILLIAMS COLOR ACCENT / CANOPYS / WINDOWS SHERWIN WILLIAMS SW7069 IRON ORE SHERWIN WILLIAMS SW7069 IRON OREACCENT WALL COLOR SW7069 IRON ORE 4 FIBER CEMENT PANELS NICHIHA ROUGHSAWN - "SMOKE" PACER WHITE SW6098 NEW BUILDING" BLADE" SIGN - UNDER SEPARATE PERMIT. NEW WALL SIGN UNDER A SEPARATE PERMIT INDICATES ROOF BEYOND. NEW METAL COPING. FIBER CEMENT PANEL OVER EXISTING WALL EXISTING AWNING, REPLACE FABRIC EXISTING MURAL, NO WORK INSTALL FACTORY OUTSIDE CORNER TO MATCH CEMENT BOARD PANEL. 7 8 9 10 11 12 PATCH AND REPAIR EXISTING STUCCO PRIOR TO PAINTING WALL. NEW EIFS TRIM. SEE DETAIL EXISTING TRIM, TYPICAL 13 14 NEW WINDOW / STOREFRONT. SEE WINDOW SCHEDULE SAND AND CLEAN ALL EXISTING WINDOW FRAMES, PAINT PER SCHEDULE 15 16 17 18 NEW LIGHT FIXTURE, SEE ELECTRICAL PLANS NEW MURAL BY OTHERS NEW ALUMINUM CANOPY WITH LETTERS BY VENDOR UNDER A SEPARATE PERMIT NEW ALUMINUM STOREFRONT. SEE A1.1 DEMO DOOR DEMO SIGN1 2 3 4 5 DEMO FABRIC AWNING DEMO LIGHT AND EXPOSED CONDUIT DEMO WINDOW 6 DEMO PORTION OF WALL DEMOLITION NOTES 1 2 2 4 5 1 17 17 (E) URM WITH FURRING 6' & 10' HORIZONTAL PANEL OUTSIDE CORNER DETAIL- NICHIHA PRE-MANUFACTURED CORNER - METHOD 1 NICHIHA PANEL NICHIHA CLIP NICHIHA CORNER (E)URM WALL METAL FURRING CHANNEL SCALE: NTS NOTES: 1.THIS CONCEPTUAL DETAIL IS A GUIDE FOR INSTALLATION OF NICHIHA PRODUCTS. ARCHITECTS/ENGINEERS/CONTRACTORS ARE RESPONSIBLE FOR SUCCESSFUL APPLICATION WHICH DEPENDS UPON SUBSTRATE DESIGN AND CONSTRUCTION BUILT IN ACCORDANCE WITH BEST PRACTICES AND LOCAL BUILDING CODES. 2.NICHIHA PANEL REPRESENTED HERE IS 5/8" NICHIHA PRODUCT, ADJUST ACCORDINGLY FOR OTHER NICHIHA PRODUCT THICKNESSES. 3.METAL FURRING CHANNEL CAN BE "Z" OR HAT CHANNEL (SHOWN HERE) AND MUST BE A MINIMUM OF 18 GA. 4.COMPLY WITH LOCAL BUILDING CODE FOR REQUIREMENT OF WRB. 18 GA FLAT STOCK METAL FABRICATED TO WRAP OUTSIDE CORNER 112" CUT ULTIMATE CLIP SEALANT OVER DOUBLE FLANGE SEALANT BACKER SIDING DETAIL 1/4" = 1'-0"E 10 mm - CMU - RECESSED WINDOW JAMB DETAIL WITH FACTORY CORNER (OR APPORVED EQUAL) NICHIHA PANEL SEALANT OVER DOUBLE FLANGE SEALANT BACKER SEALANT PANEL CLIP WEATHER RESISTANT BARRIER NICHIHA FACTORY CORNER OVER CUT PANEL CLIPS URM WALL 18 GAUGE FLAT STOCK METAL FABRICATED TO WRAP OUTSIDE CORNER SCALE: NTS (E) URM WITH FURRING 6' & 10' HORIZONTAL PANEL OUTSIDE CORNER- STUCCO TRANSITION DETAIL- NICHIHA PRE-MANUFACTURED CORNER (OR APPORVED EQUAL) NICHIHA PANEL NICHIHA CLIP NICHIHA CORNER (E)URM WALL METAL FURRING CHANNEL SCALE: NTS 18 GA FLAT STOCK METAL FABRICATED TO WRAP OUTSIDE CORNER 112" CUT ULTIMATE CLIP FLASHING BY OTHERS 1" STUCCO BROWN COAT D, E A4.1 C A4.1 SIDING DETAIL 1/4" = 1'-0"D SIDING DETAIL 1/4" = 1'-0"C 6'-8"42'-3" 12 NEW GLASS FOLDING WINDOW, SEE DOOR SCHEDULE 19 GRAFFITI COATING OVER MURAL. 19 (E) ORIGINAL PIZZA SIGN 23.5 SF TOTAL6'-3"3'-912"13'-11"2'-9"(E) ORIGINAL PIZZA AND COCA COLA SIGNS 33.5 SF TOTAL 30" 32 3/4" 0.125 ALUM FACE PAINT HANGINGTABS FLAT BLACKALL AROUND (2) TBD* TBD* 2" 1/4-20 X 3/4" WELD STUDS (12) 0.75" X 1-7/8" LG SPACER (12) LOCATION KISS-CUTS (0.014" DP)FOR WELD STUDS (12) NOTE:PAINT SEMIGLOSS WHITE SPECIFICATIONS:LAMPS: N/A 1.POWER SUPPLY: N/A2.VOLTAGE: N/A3.TOTAL CONN. LOAD: N/A4.PAINT SPECIFICATIONS:5.ALUM LOGO: SEMIGLOSS WHITE; HANGING TABS: FLAT BLACKMAXIMUM DESIGN WIND LOAD: 35 PSF6.EST. WEIGHT OF CRATED SIGN: ___ LBS7.EST. WEIGHT OF UNCRATED SIGN: ___ LBSCRATED VOLUME OF SIGN: ____CU FT8.* - WELD STUDS/SPACERS TO BE LOCATED PER WINDOWMULLIONS. INSTALLER TO PROVIDE APPROPRIATEFASTENERS FOR SPACERS. A -------------------------- SYM DESCRIPTION DRWN DATE ECN D C B AA B C D 12345678 8 7 6 5 4 3 2 1 THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OFEVERBRITE L.L.C. ANY REPRODUCTION IN PART OR AS A WHOLEWITHOUT THE WRITTEN PERMISSION OF EVERBRITE L.L.C. IS PROHIBITED. PROPRIETARY AND CONFIDENTIAL NEXT ASSY USED ON APPLICATION DIMENSIONS ARE IN INCHESTOLERANCES:FRACTIONAL 1/16"ANGULAR: MACH 1 DEG BEND 1 DEGTWO PLACE DECIMAL .010THREE PLACE DECIMAL .010 INTERPRET GEOMETRIC TOLERANCING PER: FINISH DRAWN CHECKED ENG APPR. MFG APPR. Q.A. COMMENTS: DATENAME TITLE: SIZEB DWG. NO.REV WEIGHT: SCALE: 1:12UNLESS OTHERWISE SPECIFIED: A DAP 05/23/17 SHEET 1 OF 1 PROJ362713A DO NOT SCALE DRAWING MATERIAL SIGN,TB 2'6"X 2'8-3/4" FLAT LOGO   TACO BELL CANTINA   2121 W Balboa Blvd Newport Beach CA               SIGN LEDGEND    Blade sign 8’4”h x 1’6”w @ 13 Square feet   Blade sign 8’4”h x 1’6”w @ 13 Square feet   Wall Signs with Canopy 53”h x 59”w  @21.71 Square feet   Existing sign – TK Burger 4’6”h x 8’w @ 36 Square feet