HomeMy WebLinkAbout20191010_Plans_ApprovedI I SESSIONS WEST COAST DEL I FASHION ISLAND - TENANT IMPROVEMENT CONTRACTOR BID SET PROJECT TEAM DESIGNER: SD DESIGN STUDIO, LLC. 206 W.IVYST. SAN DIEGO. CA 92101 P: (619) 561-0546 EMAIL: mcbcorp@sbcglobal.nel CONTACT: SALOMON DANIEL OWNER: IRVINE COMPANY ATTN: 550 NEWPORT CENTER DR. NEWPORT BEACH. CA 92660 CLIENT/ TENANT: SESSIONS WEST COAST DELI CONTACT: MATT MEDDOCK _ (714) 457-9747 Email : motl@sessionswcd ,com -VICINITY MAP ·ii ~ '\.;~~~9-I /,.,, I Q,-,-~"·"'"··"• DICCAIJY0/1 ~,\ / / ~ !·:,~~!(· l I --.ib,q-._/···) ,~, ., ... ,~ PROJECT SUMMARY SCOPE OF WORK : (TENANT IMPROVEMENT) OF SINGLE STORY EATING ESTABLISHMENT TO INCLUDE MINOR COSMETIC WORK TO EXTERIOR: REMOVAL & ADDITION OF INTERIOR NON STRUCTURAL PARTITION WALL: ADDITION OF SOME NEW INTERIOR EQUIPMt:NT AND ALL OTHER EQUIPMENT EXISTING AND SHALL REMAIN; EXISTING ELECTRICAL PLUMBING, MECHANICAL AND DUCTING TO REMAIN AND/OR RELOCATED; REMOVAL OF ( 3 JI E J WINDOWS & REPLACE W/ ( 2) NEW VERTICAL FOLDING WINDOWS. (NO ADDITIONAL SQUARE FOOTAGE BEING PROPOSED) PROJECT ADDRESS: 401 NEWPORT CENTER DR. -STE IOIX NEWPORT BEACH. CA 92660 APPLICABLE CODES: 2016 CALIFORNIA BUILDING CODE: 2016 CALIFORNIA MECHANICAL CODE; 2016 CALIFORNIA PLUMING CODE; 2016 CALIFORNIA ELECTRICAL CODE: 2016 CALIFORNIA FIRE CODE; 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE; 20 I 6 CALIFORNIA ENERGY CODE TECHNICAL DATA: APN; ZONING; TYPE OF CONSTRUCTION : FIRE SPRINKLER SYSTEM ; OCCUPANCY CLASSIFICATION/ USE EXISTING FLOOR AREA (NO CHANGE)· 1,110S.F. C-36 (GENERAL COMMERCIAL) TYPE VB YES A-2 / B · FOOD AND/OR DRINK RESTAURANT TENANT IMPROVEMENT NOTES FIRE DEPARTMENT NOTES l. CONSTRUCTION DOCUMENTS APPROVED BY THE FIRE CODE OFFICIAL ARE IMPROVED WIIH THE INTENT THAT SUCH INSTRUCTION DOCUMENTS COMPLY IN All RESPECTS WITH CURRENT CODE. REVIEW AND APPROVAL BY THE FIRE CODE OFFICIAL SHALL NOT RELIEVE THE APPLICANT OF THE RESPONSIBILITY OF COMPLIANCE WITH THIS CODE. {CFC I 05.4.4) 2. COMPLETE PLANS AND SPECIFICATIONS FOR FIRE ALARM. FIRE SPRINKLER. OTHER SPECIAL TYPES OF AUTOMATIC FIRE PROTECTION SYSTEMS AND APPURTENANCES THERETO, AND WET AND DRY STANDPIPES SHALL BE SUBMITTED TO FIRE FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. {CFC 901, 903.1.1, 905, 907.1.1) 3. BUILDINGS UNDERGOING CONSTRUCTION, ALTERATION OR DEMOLITION SHALL CONFORM TO CFC CHAPrER 33. WELDING. CUTTING. AND OTHER HOT WORK SHALL BE IN CONFORMANCE W/ CFC CHAPTER 35. 4. DECORATIVE MATERIALS SHALL BE MAINTAINED IN A FLAME-RETARDANT CONDITION (CFC 8071). 5. FIRE EXTINGUISHING SYSTEMS SHAll BE INSTALLED IN ACCORDANCE WITH CFC 903 & 904. & COMPLY WITH STANDARDS OF 903.3. 6. ALARM SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH CFC 907 7. VALVES CONTROLLING THE WATER SUPPLY FOR AUTOMATIC SPRINKLER SYSTEMS AND WATER-FLOW SWITCHES ON ALL SPRINKLER SYSTEMS SHALL BE ELECTRICALLY MONITORED WHERE THE NUMBER OF SPRINKLERS IS 20 OR MORE /CFC 903.4) B. AN APPROVED AUDIBLE SPRINKLER FLOW ALARM (BELL) SHALL BE PROVIDED ON THE EXTERIOR OF THE BUILDING IN AN APPROVED LOCATION (CFC903.4.2) 9. ADDRESS SHALL BE PROVIDED FOR All NEW AND EXISTING BUILDINGS IN A POSITION AS TO BE PLAINLY V~IBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. WHERE ACCESS ISBY WAY OF A PRIVATE ROAD AND THE BUILDING ADDRESS CANNOT BE VIEWED FROM THE PUBLIC WAY AN APPROVED SIGN OR MEANS SHALL BE USED TO IDENTIFY THE STRUCTURE. PREMISES IDENTIFICATION SHAll CONFORM TO CBC SEC. 505.1.2 (CFC 505) 10. TWO EXIT OR EXIT ACCESS DOORS REQUIRED FOR A. B. E.F.M., LI WHEN OCCUPANT LOAD> 49 {CBC 20013 SEC. 1015.l) 11. DOORS MUST SWING IN DIRECTION OF TRAVEL WHEN SERVING AN OCCUPANT LOADOF500R MORE OR A GROUP H (CFC 1008.1.2) 12. GROUP 'A' OCCUPANCIES WITH ROOMS OR SPACES HAVING AN OCCUPANT LOAD OF 50 OR MORE. ASSEMBLY AREA NOT CLASSIFIED AS AN ASSEMBLY OCCUPANCY OR GROUP H. E. 1-2 OR 1-2.1 OCCUPANCIES SHALL NOT BE PROVIDED WITH A. A LATCH OR LOCK UNLESS B. IS PANIC HARDWARE OR FIRE EXIT HARDWARE (CFC 1008.1. JO} 13. ANY ROOM OR SPACE THAT IS AN ASSEMBLY OCCUPANT SHALL HAVE THE MAX. CAPACITY OF THE ROOM POSTED ON AN APPROVED SIGN IN A CONSPICUOUS PLACE NEAR THE MAIN EXIT FROM THE ROOM. SIGNS SHALL BE OF AN APPROVED LEGIBLE PERMANENT DESIGN (CFC 1004.3). 1.4. PROVIDE ILLUMINATED EXIT SIGNS SUCH THAT NO PIONT JN AN EXIT ACCESS CORRIDOR IS MORE THAN 100 FT. OR THE LISTED VIEWING DISTANCE FOR THE SIGN, WHICHEVER IS LESS. FROM THE NEAREST VISIBLE EXIT SIGN (CBC IOI 1.1) LOCATION SHOWN ON PLANS & DOOR SCHEDULE (IF APPLICABLE) 15. ANY TIME A BUILDING IS OCCUPIED. THE MEANS OF EGRESS SHALL BE ILLUMINATED AT ANY INTENSITY OF NO LESS THAN I FOOT CANDLE AT FLOOR LEVEL (CFC 1006. !. l 006.2) 16. EGRESS ILLUMINATION REQUIRES A SOURCE OF EMERGENCY POWER (CFC 1006.3) 17. MAIN EXIT CAN HAVE A DEADBOLT IF SIGN ATTACHED· iHJS DOOR MUST REMAIN UNLOCKED DUS~ING BUSINESS HOURS" (CBC SEC. 1006.1.9) A MAIN EXIT OF A GROUP 'A' OCCUPANCY COMPLIANCE WITH ICBC SEC. 1008.1.3) ITEM 2: IN BUILDINGS IN OCCUPANCY GROUP 'A' OCCUPANT LOAD OF 300 OR LESS. GROUP "B' F.M. ABD S. AND PLACES OF RELIGIOUS WORSHIP. THE MAIN EXTERIOR DOOR(SJ PERMITTED TO BE EQUIPPED WITH KEY OPERATED LOCKING DEVICES FROM EGRESS SIDE; 2.1 LOCKING DEVICE IS DISTINGUISHABLE AS LOCKED 2.2 THE SIGN IS POSTED WI lffiERS 1" IGH ON CONTRASTING BACKGROUND 18. LOCATIONS & CLASSIFICATIONS OF EXTINGUISHERS SHALL BE IN ACCORDANCE WI CFC 906 & CALIFORNIA CODE OF REGULATIONS (CCR). TITLE 19. 19. DURING CONSTRUCTION. AT LEAST ONE EXTINGUISHER SHALL BE PROVIDED ON EACH FLOOR LEVEL Al EACH STAIRWAY, IN All STORAGE AND CONSTRUCTION SHEDS, IN LOCATIONS WHERE FLAMMABLE OR COMBUSTIBLE LIQUIDS ARE STORED OR USED. AND WHERE OTHER SPECIAL HAZARDS ARE PRESENT PER CFC SEC.3315.I 20. WALL, FLOOR & CEILING FINISHES & MATERIALS SHALL NOT EXCEED THE INTERIOR FINISH CLASSIFICATIONS IN CBC TABLE 803.1.1 AND SHALL MEET THE FLAME PROPAGATION PERFORMANCE CRITERIA OF THE CALIFORNIA CODE OF REGULATIONS, TITLE 19, DIV. I. DECORATIVE MATERIALS SHALL BE PROPERLY TREATED BY A PRODUCT OR PROCESS APPROVED BY THE STATE FIRE MARSHAL W/ APPROPRIATE DOCUMENTATION PROVIDED TO THE CITY OF SAN DIEGO. 21. DUMPSTERS AND TRASH CONTAINERS EXCEEDING 1.5 CUBIC YARDS SHALL NOT BE STORED IN BUILDINGS OR PLACED WITHIN 5 FEET OF COMBUSTIBLE WALLS. OPENINGS OR COMBUSTIBLE ROOF EA YE LINES UNLESS PROTECTED BY AN APPROVED SPRINKLER SYSTEM OR LOCATED IN A TYPE I OR I/A STRUCTURE SEPARATED BY IO FEET FROM OTHER STRUCTURES. CONTAINERS LARGER THAN I CUBIC YARD SHALL BE OF NON· OR LIMITED-COMBUSTIBLE MATERIALS OR SIMILARLY PROTECTED OR SEPARATED. CFC 304.3 22. EXITS, EXIT SIGNS, FIRE ALARM PANELS. HOSE CABINETS, FIRE EXTINGUISHER LOCATIONS, AND STANDPIPE CONNECTIONS SHALL NOT BE CONCEALED BY CURTAINS. MIRRORS. OR OTHER DECORATIVE MATERIAL. 23. OPEN FLAMES, FIRE. AND BURNING ON ALL PREMISES IS PROHIBITED EXCEPT AS SPECIFICALLY PERMITTED BY THE CITY OF SAN DIEGO AND CFC 308. 24. THE EGRESS PATH SHALL REMAIN FREE AND CLEAR OF All OBSTRUCTIONS AT All TIMES. NO STORAGE IS PERMITTED IN ANY EGRESS PATH 1. FLAME SPREAD CLASSIFICATIONS FOR INTERIOR WALL AND CEILING FINISHES SHALL COMPLY W/ 2016 CBC TABLE 803.5 4 ALL DOORS IN THE MEANS OF EGRESS SHALL BE OPENABLE FROM EGRESS SIDE W/0 USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. AND THATTHE UNLAiCHING OF ANY DOOROR LEAF SHALL NOT REQUIRE MORE THAN ONE OPERATION. (CBC 1008.1.8. 6 MANUALLY OPERATED FLUSH BOLTS OR SURFACE BOLTS ARE NOT PERMITTED ON DOORS. {CBC 1008.1.8.4) 2. PROPOSED FLOOR FINISHES SHALL COMPLY W/ ASTM E64B AND SHALL HAVE STM E84 SMOKE DENSITY RATING OF LESS THAN 45D [CBCB04.4.I) 3. If EXTERIOR FINISHES ARE ALTERED. EXTERIOR WATER RESISTIVE BARRIERS WHEN APPLIED OVER WOOD BASED SHEATHING SHALL INCLUDE A WATER-RESISTIVE VAPOR-PERMEABLE BARRIER W. A PERFORMANCE AT LEAST EQUIVEANT TO 2 LAYERS OF GRADE 'D' PAPER; OR AT LEAST I LA YER OF WATER-RESISTIVE BARRIER EQUAL OF GREATER THAN 60-MIN. GRADE 'D' PAPER AND W/ A SEPARATION FORM THE EXTERIOR FINISH BY AN INTERVENING SUBSTANTIALLY NON WATER-ABSORBING LAYER OR DRAINAGE SPACE. (CBC 2510.6) I 1008.1 .8.5) 5. FOR GROUP 'A-2' OCCUPANCIES, KEY OPERATED LOCKING DEVICES FROM THE EGRESS SIDE MAY BE USED ON THE MAIN EXTERIOR DOORS PROVIDED; A. THE LOCKING DEVICE IS READILY DISTINGUISHABLE AS LOCKED AND, 8. THERE IS A READILY VISIBLE DURABLE SIGN ON OR ADJACENT TO THE DOOR STATING 'THIS DOOR MUST REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED" AND, C, THIS SIGN SHALL BE IN LETTERS NOT LESS THAN 1 INCH HIGH ON A CONTRAST BACKGROUND; AND D. THE USE OF THIS EXCEPTION MAY BE REVOKED BY THE BUILDING OFFICIAL AT ANYTIME FOR DUE CAUSE. (CBC 1008.1.8.31 7. EFFORT TO OPERATE EACH ACCESSIBLE DOO RNOT TO EXCEEDS POUNDS FOR EXTERIOR AND INTERIOR DOORS. EFFORT TO OPERATE FIRE DOORS MAY BE INCREASED TO MIN. ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY, NOT TO EXCEED 15 POUNDS. (CBC 11336.2.5) 8. DOORS W/ SELF-CLOSERS TO BE ADJUSTED SO THAT FROM OPEN POSITION THE DOOR LEAF WILL TAKE AT LEAST 3 SECONDS TO MOVE A POSITION 3 INCHES FROM LATCH TO LANDING EDGE OF DOOR. (CFC I 13B.2.5.I} I I GENERAL NOTES J. FJELD VERIFY ALL DIMENSIONS. 2. GC SHALL TAKE ALL NECESSARY PRECAUTIONS & MEASURES TO PROTECT All EXISTING FLOORS. WALLS, ETC. ON THE JOB SITE & REPAIR ALL DAMAGES OCCURRING THERETO DURING REMODEL OPERATIONS. THE JOB SITE SHALL BE MAINTAINED CLEAN AND ORDERLY, FREE OF DEBRIS AND LITTER. AND SHALL NOT BE UNREASONABLE ENCUMBERED WITH ANY MATERIAL OR EQUIPMENT. GC TO REMOVE TRASH AND DEBRIS UPON COMPLETION OF EACH PHASE OF WORK. 3. CONTRACTOR TO VISIT SITE TO MAKE HIS OWN ASSESSMENT OF EXISTING CONDITIONS. ACCESS & THE IMPACT OF THE WORK SHOWN ON THESE DRAWINGS. CONTRACTOR TO NOTIPf DESIGNER FOR CLARIFICATION OF ANY DISCREPANCIES FOUND BETWEEN THESE DOCUMENTS & THAT WHICH IS AT THE SITE. 4. GC & ELECTRICAL SUBCONTRACTORS ARE RESPONSIBLE FOR PROVIDING PROPER LOCATIONS & REQUIREMENTS OF CORE DRILLS & ELECTRICAL OUTLETS (GFCI, DEDICATED, ETC.) ACCORDING TO THE DESIRED LOCATION OF ITEMS PER THESE DRAWINGS AS WELL AS TO MEET CODE. 5 GC &. PLUMBING SUBCONTRACTORS ARE RESPONSIBLE FOR PROVIDING PROPER LOCATIONS & REQUIREMENTS OF CORE DRILLS. PLUMBING STUB OUTS 8. PLUMBING LINES (HOT AND/OR COLD) ACCORDING TO THE DESIRED LOCATION OF ITEMS PER THESE DRAWINGS 6 GC & MILL WORK SUBCONTRACTORS ARE RESPONSIBLE FOR PROVIDING PROPER LOCATIONS & REQUIREMENTS OF CORE DRILLS &ADDITIONAL BLOCKING (WALL. CEILING. CABINETRY. ETC.) ACCORDING TO THE DESIRED LOCATION OF ITEMS PER THESE DRAWINGS. 7, IF CONFLICTS OR DISCREPANCIES EXIST OR ARISE. CONTRACTOR TO CONTACT DESIGNER ASAP. 8. CONTRACTOR SHALL NOTIFY DESIGNER OF ANY POSSIBLE CONSTRUCTION DELAYS AFFECTING OCCUPANCY THAT MAY ARISE DUE TO THE AVAILABILITY OF SPECIFIED PRODUCTS 9. SHOP AND FIELD WORK SHALL BE PERFORMED BY MECHANICS, CRAFTSMEN. AND WORKERS SKILLED AND EXPERIENCED IN THE FABRICATION AND INSTALLATION OF THE WORK INVOLVED. WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE BEST ESTABL~HED PRACTICE OF THE INDUSTRY STANDARD FOR THE TRADES INVOLVED. 10. THE CONTRACTOR SHALL NOT PROCEED WITH ANY WORK REQUIRING ADDITIONAL COMPENSATION BEYOND THE CONTRACT AMOUNT WITHOUT WRITTEN AUTHORIZATION. FAILURE TO OBTAIN AUTHORIZATION FROM OWNER'S REPRESENTATIVE WILL INVALIDATE ANY CLAIM FOR EXTRA COMPENSATION. I I. THERE SHALL BENO SUBSTITUTIONS OF MATERIALS WHERE A MANUFACTURER IS SPECIFIED. WHERE THE TERM "OR APPROVED EQUAL .. l'i USED. CONTRACTOR IS TO SUBMIT ALTEii:NATIVE MATERIAL TO DESIGNER FOR APPROVAL BEFORE CONTINUING WORK. 12. CONTRACTOR SHALL COORDINATE THE WORK WITH THE TENANT AND BUILDING OWNER SO AS TO MINIMIZE OR ELIMINATE INTERFERENCE WITH ONGOING TENANT OPERATIONS. 13. CONTRACTOR SHALL SCHEDULE AND PERFORM THE WORK DURING NORMAL WORKING HOURS UNLESS OTHERWISE APPROVED BY OWNERS REPRESENTATIVE 14. CONTRACTOR TO 03TAIN REQUIRED PERMITS PRIOR TO COMMENCEMENT OF WORK. COORDINATE INSPECTIONS AND APPROVALS IN All ASPECTS OF THE WORK. OBTAIN A FINAL CERTIFICATE OF OCCUPANCY AND MAINTAIN A PERMITTED SET OF DOCUMENTS ON SITE FOR THE DURATION OF THE PROJECT. 15. DURING DEMOLITION GC TO VERIFY ALL EXISTING CONDITIONS AND NOTIFY ARCHITECT AND OWNER OF ANY EXISTING CONDITIONS THAT Will ALTER DESIGN INTENT OR REQUIRE ADDITIONAL SCOPE OF WORK. 16. ANY EXISTING ABANDONED WIRING. SWITCHPLATES. SPEAKERS, ETC. WITHIN THE SCOPE AREA TO BE REMOVED. CONFIRM W/OWNER. l 7. ANY EXISTING FIRE ALARM EQUIPMENT. FIRE HOSE CABINETS, FIRE EXTINGUISHERS, STROBES, ETC. ON EXISTING PARTITIONS TO REMAIN TO BE PRESERVED & PROTECTED DURING DEMOLITION. 18. ALL CODE COMPLIANCE FOR ENTIRE PROJECT MUST BE THE RESPONSIBILITY OF THEG.C. 19, DESIGNER Will REVIEW ALL MILLWORK SUBMITTALS FOR COMMENCEMENT OF WORK I SHEET INDEX Tl TJTLESHEET / PROJECT DATA SPl ACCESSIBILITY NOTES&. TYPICAL DETAILS ARCHITECTURAL Al SITEPlAN A2 DEMOLITION (EXISTING) FLOOR PLAN/ PARTITION PLAN A3 FINISH PLAN PLAN/ REFLECTED CEILING-LIGHTING PLAN A4 EQUIPMENT PlAN & SCHEDULE AS INTERIOR ELEVATIONS A6 INTERIOR ELEVATIONS/ EXTERIOR ELEVATIONS Al EXTERIOR ELEVATIONS/ DOOR &. WINDOW SCHEDULE ~ K-01 FOOD SERVICE FLOOR PLAN K-02 FOOD SERVICE EQUIPMENT SCHEDULE K-03 FOOD SERVICE DRAIN PLAN K-04 FOOD SERVICE WATER PLAN K-05 FOOD SERVICE ELECTRICAL PLAN © SD DESIGN STUDIO, LLC 8. RUSH CREATIVE STUDIO SESSIONS WEST~-~~, COAST DELI AT FASHION ISLAND [MACY'S) INTERIOR REMODEL T.I. 401 NEWPORT CENTER DR. SUITE IOI X, FASHION ISLAND NEWPORT BEACH, CA 92660 u~ .J 0 .J 0 o-o Q Cl ::::> ::, f- l-(f) Cf) z (!) z-0: -Cl Cf) Cl w (fJ 0~ 03 Cf) 3 d 0 ::::, 1- (/) llJ > I- <( llJ c::: 0 I (/) ::::, 0:: s DD s ~ 0 0 0 Cl ::::> f- en w > f- <t: w CJ:'. 0 :c U) ::::> CJ:'. 3: 3: 3: Num Description Dsite 8/22/19 AS NOTED SDDS & RUSH CS PROJECT NUMBER: 1906 TITLE SHEET / PROECT DATA TS PA2019-141 ZONING ADMINISTRATOR 10/10/2019 - APPROVED (8 PAGES) ~ 18" MIN. 24" MIN. J @ EXTERIOR I TACTILE EXIT ROUTE SIGN EXIT ROUTE • •• • • • • • • • • • •• •• • •• • •• • • • •• • TACTILE EXIT SIGN EXIT • • • • • • • •• •• • 1. RAISED CHARACTERS SHALL COMPLY WITH 11 B-703.2 RAISED CHARACTERS ANO SHALL BE DUPLICATED IN BRAfll COMPLYING WITH 118-703.3 BRAILLE. RAISED CHARACTERS SHALL BE INSTALLED IN ACCORDANCE WITH 118-703.4 INSTALLATION H8GHT AND LOCATION. §118-703.2 A R.OJSED CHARACTERS SHALL BE 1/32 INCH MINIMUM ABOVE THEIR 8'CKGROUND. §11B-7D3.2. l B. CHARACTERS SHALL BE UPPERCASE. §1 lB-7D3.2.2 C. CHARAClERS SHALL BE SANS SERIF. CHARACTERS SHALL NOT BE ITALIC, OBLIQUE, SCRIPT, HIGHLY DECORATIVE, OR or OTHER UNUSUAL FOR•S. §118-703.2.3 FIG. 118-404.2.4.1 D. CHARACTERS SHALL BE SELECTED fROM fONTS WHERE THE 111DTH or THE UPPERCASE LETTER ·o· IS 55 60 1----------------------------j ~rn~:r_.;;~M~~K;:D .~;~~c~;~~u~g~ ~~ :,E~N~'o!H~Ht~~=E~~:1iE §~;:~~~~2M~NIMU ~C_;_L_E_A_R_D_Q_;_O_R_W_I_D_T_H_& __ D_E_P_T_H _________ --1~~~1:{~~~c~~~~u~r~~ou~~E;~~E::rt?~=~~ ~~~-1~1~~0;7g(~5E HEK.HT or THE MAX. CLEAR FLOOR SPACE PARALLEL APPROACH FIG. 116-308.3, 1 30• 30" W,g;_\ MAX. -(a) UNOBSTRUCTED SIDE REACH 30" CHARACTER. §118-703.2.6 G. CHARAClER SPACING SHALL BE MEASURED BETWEEN THE TWO CLOSEST POINTS OF ADJACENT RAISED CHARAClERS WITHIN A MESSAGE, EXCLUDING WORD SPACES. WHERE CHARACTERS HAVE RECTANGULAR CROSS SECTIONS, SPACING BETWEEN INDMDUAL R/IJSED CHARACTERS SHALL BE I /8 INCH MINIMUM ~0 4 TIMES THE RAISED CHARACTER STROKE 111DTH MAXIMUM. WHERE CHARACTERS HAVE OTHER CROSS SECTIONS, SPACING BETWEEN INDMDUAL RAISED CHARACTERS SHALL BE 1 / 16 INCH MINIMUM AND 4 TIMES THE RAISED CHARACTER STROKE WIOT MAXIMUM AT THE WE Of THE CROSS SECTIONS, AND 1/8 INCH MINIMUM AND 4 TIMES THE RAISED CHARACTER STROKE 111DTH MAXIMUM AT THE TOP Of THE CROSS SECTKINS. CHARACTERS SHALL BE SEPARATED fROM il.'JSED BORDERS AND DECORATIVE ELEMENTS 3/B INCH MINIMUM. §I 18-703.2.7 H. SPACING BETWEEN THE BASELINES or SEPARATE LINES or RAISED CHARACTERS WITHIN A MESSAGE SHALL BE t35 PERCENT MINUWM AND 170 PERCENT MAXIMUM or THE RAISED CHARACTER HEIGHT. §11B-703.2.8 I. TEXT SHALL BE IN A HORIZONTAL FORMAT. §118-703.2.9 2. BRAILLE SHALL BE CONTRAClED (GRADE 2) AND SHALL COMPLY WITH 118-703.3 Sil.'JLLE AND ll8-7D3.4 INSTALLATION HEIGHT AND LOCATION. §118-703.3 A Bil.'JLLE DOTS SHALL HAVE A DOMED OR ROUNDED SHAPE AND SHALL COMPLY 111TH TABLE 11B-703.3.1. THE INDICATION Of AN UPPERCASE LETTER OR LETTERS SHALL ONLY BE USED BEFORE THE FIRST WORD Of SENTENCES, PROPER NOUNS AND NAMES, INDMDUAL LETTERS or THE ALPHABET, INITIAl5, AND ACRONYMS. § 118-703.3. 1 B. BRAILLE SHAll BE POSmONED BELOW THE CORRESPONDING TEXT IN A HORIZONTAL FORM.AT, FLUSfi LEFT OR CENTERED. IF TEXT IS MULTI-LINED, BRAILLE SHALL BE PLACED BELOW THE ENTIRE TEXT. BRAlllE SHALL BE SEPARATED 3/8 INCH MINIMUM AND 1/2 INCH MAXIMUM FROM ANY OTHER TACTILE CHARACTERS AND 3/B INCH MINIMUM FROM RAISED BORDERS AND DECORATIVE ELEMENTS. § 118-703.3.2 (SEE EXCEPTION) 3. SIGNS 1111TH TACTILE CHARACTERS SHALL COMPLY WITH 11B-703.4 INSTALLATION HEIGHT AND LOCATION. §118-703.4 A TACTILE CHARACTERS ON SIGNS SHALL BE LOCATED 48 INCHES MINIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE, MEASURED fROM THE 8'SELINE Of' THE LOWEST TACTILE CHARACTER Bil.'JLLE CELLS ANO 60 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND SURfACE, MEASURED FROM THE BASELINE Of THE HIGHEST TACTILE CHARACTER LINE OF RAISED CHARACTERS. §11B-703.4.1 (SEE E>CEPTON) 8. WHERE A TACTILE SIGN IS PROVIDED AT A DOOR, THE SIGN SHALL BE LOCATED ALONGSIDE THE DOOR AT THE LATCH SIDE. WHERE A TACTILE SIGN IS PROVIDED AT DOUBLE DOORS WITH ONE ACTM LEAF', THE SIGN SHALL BE LOCATED ON THE INACTIVE LEAF. WHERE A TACTIL£ SIGN IS PROVIDED AT DOUBL£ DOORS WJTH lWO ACTIVE LEAfS, THE SIGN SHALL BE LOCATED TO THE RIGHT Of THE RIGHT HANO DOOR. WHERE THERE IS NO WALL SPACE Al THE LATCH SIDE or A SINGLE DOOR OR AT THE RIGHT SIDE or DOUBLE DOORS, SIGNS SHALL BE LOCATED ON THE NEAREST ADJACENT WALL. SIGNS CONTAINING TACTLE CHARACTERS SHALL BE LOCATED SO THAT A CLEAR FLOOR SPACE or 18 INCHES MINIMUM BY 18 INCHES MINIMUM, CENTERED ON THE TACTILE CHARACTO!S, IS PROVIDED BEYOND THE ARC or ANY DOOR S111NG BETWEEN THE CLOSED POSmON AND 45 DEGREE OPEN POSmON. WHERE PERMANENT IDENTIFICATION SIGNAGE IS PROVJDEO fOR ROOMS ANO SPACES THEY SHALL BE LOCATED ON THE APPROACH SIDE Of THE DOOR AS ONE ENTERS THE ROOM OR SPACE. SIGNS THAT IDENTifV EXITS SHALL BE LOCATED ON THE APPROACH SIDE OF THE DOOR AS ONE EXITS THE ROOM OR SPACE. 118-703.4.2 (SEE EXCEPTION) 4. VISUAL CHARACTERS SHALL COMPLY WITH THE FOLLOWING, EXCEPT WHERE VlSUAL CHARACTERS COMPLY WITH 11B-70J.2 RAISED CHARACTERS ANO ARE ACCOMP~IED BY BRAILLE COMPLYING WITH 11B-703.J BRAILLE, THEY SHALL NOT BE REQUIRED TO COMPLY WITH 11B-703.5.2 THROUGH 118-7D3.5.6, 118-703.5.8 AND 11B-703.5.9: A CHARAClERS AND THEIR 8'CKGROUND SHALL HAVE A NON-GLAAE FlNISH. CHARACTERS SHALL CONTRAST WITH _]__,L__ L.---.1-1-JL;;;;;;......,;;;;;;;JJ._ I THEIR 8'CKGROUND 111TH EITHER LIGHT CHARACTERS ON A DARK BACKGROUND OR DARK CHARACTERS ON A (b) FIG. 11 B-308.3.2 OBSTRUCTED SIDE REACH )10" -24" MAX. (c) LIGHT BACKGROUND. § I I B-7D3.5. l B. CHARAClERS SHALL BE UPPERCASE OR LOWERCASE OR A COMBINATION or BOTH. § 118-703.5.2 C. CHARAClERS SHALL BE CONVENTIONAL IN FORM. CHARACTERS SHALL NOT BE ITALIC, OBLIQUE, SCRIPT, HIGHLY DECORATIVE, OR or OTHER UNUSUAL FORMS. §11 B-703.5.3 O. 0. CHARACTERS SHALL BE SELEClED FROM FONTS WHERE THE 1110TH OF THE UPPERCASE LETTER •o• IS 55 60 PERCENT MINIMUM AND 110 PERCENT MAXIMUM or THE HEIGHT or THE UPPERCASE LETTER ;·, §118-703.5.4 ~S_I_D_E_R_E_A_C_H-------------------,E. ~I~~: Jo':..:'. ~~,'.:Jc~~~~~p~E wg:~~E~ ',.'.8D-:3~Jsr:u~: ~r~~N~~~E:EASUR APPROACH TOWARDS THE SIGN. CHARACTER HEIGHT SHALL BE 8'SED ON THE UPPERCASE LffiER •1•. §11B-703.5.5 (SEE EXCEPTION) 48" MIN FIG. 118-308.2.1 (a) HIGH FORWARD REACH LIMIT 20· MAX 20•-25• MAX (b) MAXIMUM FORWARD REACH OVER AN OBSTRUCTION FIG. 118-3082.2 FORWARD REACH f. VJSUAL CHARACTERS SHALL BE 40 INCHES MINIMUM A8(JJf. THE FINISH fLOOR OR GROUND. §118-703.5.6 (SEE EXCEPTIONS) G. STROKE THICKNESS or THE UPPERCASE LETTER ·1· SHALL BE 1 D PERCENT MINIMUM AND 20 PERCENT MAXIMUM OF THE HEIGHT or THE CHARACTER. §11B-70J.5.7 H. CHARACTER SPACING SHALL BE MEASURED BETWEEN THE TWO CLOSEST POINTS OF ADJACENT CHARACTERS, EXCLUDING WORD SPACES. SPACING BETWEEN INDMDUAL CHARACTERS SHALL BE 10 PERCENT MINIMUM ANO 35 PERCENT MAXIMUM Of' CH.&HACTER HEIGHT. §118-703.5.B I. !SPACING BETWEEN THE BASELINES OF SEPARATE LINES OF CHARACTERS l\1THIN A MESSAGE SHALL BE 135 PERCENT MINIMUM AND 170 PERCENT MAXIMUM OF THE CHARACTER HEIGHT. §118-703.5.9 J TEXT SHALL BE IN A HORIZONTAL FORMAT. §11B-703.5.IO REQUIRED KNEE CLEARANCE GENERAL -IF FIXED OR BUILT-IN SEATING, TABLES OR COUNTERS (INCLUOING, BUT NOT LIMITED TO, STUDY CARRELS AND STUDENT LAB. STATIONS), ARE PROVJDED IN PUBLIC, COMMON USE, OR GENERAL EMPLOYEE AREAS, AT LEAST FIVE PERCENT (5%), BUT NOT LESS THAN ONE, MUST BE ACCESSIBLE AS DETAILED ABOVE. TABLE OR COUNTER HEIGHT 28" MIN., 34" MAX. A. MINIMUM 30''x48" CLEAR FLOOR SPACE IS PROVIDED. B. HEIGHT OF TABLES OR COUNTERS IS BETWEEN 28"-34" FROM THE FLOOR OR GROUND. C. ONE FULL UNOBSTRUCTED SIDE OF THE CLEAR FLR. SPACE ADJOINS OR OVERLAPS AN ACCESSIBLE ROUTE OR ANOTHER WHEELCHAIR CLEAR FLOOR SPACE. D. KNEE CLEARANCE AT TABLES, COUNTERS AND WORK SURFACES IS AT LEAST 27" HIGH, 30" WIDE ANO 19• DEEP. REQUIRED KNEE CLEARANCE ADA ACCESSIBILITY NOTES DISABLED ACCESS REQUIREMENTS (SEE CBC 1133.B) PARKING (SEE CBC SEC. CHAPTERS 118, 11298, 1131B) 1. SURFACE SLOPES OF PARKING SPACES FOR THE PHYSICALLY DISABLED SHALL NOT EXCEED 114 INCH PER FOOT (2.083% GRADIENT) IN ANY DIRECTION 2. ALL PARKING STRUCTURES AND PARKING GARAGES SHALL HAVE DISABLED PARKING SPACES AND ALL ENTRANCES LEADING TO DISABLED PARKING SPACES AND VEHICLE EXITS FROM DISABLED PARKING SPACES INCLUDING THE DRIVEWAY, AISLE, AND STALL AREA SHALL HAVE A MINIMUM VERTICAL CLEARANCE OF 8'-2" 3. THE 8'-2" VERTICAL DIMENTION SHALL BE CLEAR OF ALL OBSTRUCTIONS, INCLUDING BEAMS, SPRINKLER HEADS, PIPING, ETC. 4. PEDESTRIAN WAYS WHICH ARE ACCESSIBLE TO THE PHYSICALLY DISABLED SHALL BE PROVIDED FROM EACH DISABLED PARKING SPACE TO RELATED FACILITIES, INCLUDING CURB CUTS OR RAMPS AS NEEDED. WALKS AND SIDEWALKS (SEE CBC SEC. CHAPTERS 11338.7) 5. WALKS AND SIDEWALKS SUBJECT TO THESE REGULATIONS SHALL HAVE A CONTINUOUS COMMON SURFACE, NOT INTERRUPTED BY STEPS OR ABRUPT CHANGES IN LEVEL EXCEEDING 1/2 INCH, AND SHALL BE A MINIMUM OF 48 INCHES IN LENGTI-1 6. SURFACES WITH A SLOPE OF LESS THAN 6 PERCENT GRADIENT SHALL BEAT LEAST AS SLIP-RESISTANT AS THAT DESCRIBED AS A MEDIUM SALTED FINISH 7. SURFACE CROSS SLOPES SHALL NOT EXCEED 114 INCH PER FOOT 8. WALKS, SIDEWALKS, AND PEDESTRIAN WAYS SHALL BE FREE OF GRATINGS WHENEVER POSSIBLE. FOR GRATINGS LOCATED IN THE SURFACE OF ANY OF THESE AREAS, GRID OPENINGS IN GRATINGS SHALL BE LIMITED TO 112 INCH IN THE DIRECTION OF TRAFFIC FLOW 9. ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE SHALL NOT EXCEED 1/2 INCH. WHEN CHANGES IN LEVEL DO OCCUR, THEY SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2 EXCEPT THAT LEVEL CHANGES NOT EXCEEDING 1/4 INCH MAY BE VERTICAL 10. WHEN CHANGES IN LEVEL GREATER THAN 1/2 INCH ARE NECESSARY THAT SHALL COMPLY WITH THE REQUIREMENTS FOR CURB RAMPS 11. WALKS SHALL BE PROVIDED WITH A LEVEL AREA NOT LESS THAN 60 INCHES WIDE X42 INCHES+THE DOOR WIDTH AT A DOOR OR GATE THAT SWINGS TOWARD THE WALK, AND NOT LESS THAN 48 INCHES WIDE BY 60 INCHES DEEP AT A DOOR OR GATE THAT SWINGS AWAY FROMTHE WALK. SUCH WALKS SHALL EXTEND 24 INCHES TO THE SIDE OF THE STRIKE EDGE OF A DOOR OR GATE THAT SWINGS TOWARD THE WALK RAMPS (SEE CBC SEC. 11278.5) 12. ANY PATH OF TRAVEL SHALL BE CONSIDERED A RAMP IF ITS SLOPE IS GREATER THAN 1 FT RISE IN 20 FT OF HORIZONTAL RUN 13. THE CROSS-SLOPE ON A RAMP OR THE SLOPE ACROSS A RAMP LANDING IN ANY DIRECTION SHALL NOT EXCEED 1/4 INCH RISE IN 1 FOOT OF HORIZONTAL RUN 14. THE GRIP PORTION OF TI-IE HANDRAIL SHALL BE NOT LESS THAN 1-114 INCHES IN CROSS SECTIONAL DIMENSION. OR THE SHAPE SHALL PROVIDE AN EQUIVALENT GRIPPING SURFACE AND ALL SURFACES SHALL BE SMOOTH WITH NO SHARP CORNERS. 15. THE SURFACE OF RAMPS SHALL BE SLIP RESISTANT ENTRANCES(SEE CBC SEC. 11338) 16. LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE IN A PATH OF TRAVEL, SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVEL TYPE HARDWARE, PANIC BARS, PUSH-PULL ACTIVATING BARS, OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE. 17. HAND ACTIVATED DOOR OPENING HARDWARESHALL BE CENTERED BETWEEN30-INCHES AND 44-INCHES ABOVE THE FLOOR. 18. THE FLOOR OR LANDING SHALL NOT BE MORE THAN 1/2 INCH LOWER THAN THE THRESHOLD OF THE DOORWAY. CHANGE IN LEVEL BETWEEN 114 INCH AND 112 INCH SHALL BE BEVELED WITH A SLOPE OF NO GREATER THAN 1:2. 19. THE BOTTOM 10 INCHES OF ALL DOORS EXCEPT AUTOMATIC AND SLIDING SHALL HAVE A SMOOTH, UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. WHERE NARROW FRAME DOORS ARE USED, A 10 INCH HIGH SMOOTH PANEL SHALL BE INSTALLED ON THE PUSH SIDE OF THE DOOR, WHICH WILL ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. 20. MAXIMUM EFFORTTO OPERATE DOORS SHALL NOTEXCEED 8-112 LBS FOR EXTERIOR DOORS AND 5 LBS FOR INTERIOR DOORS. SUCH PUSH AND PULL EFFORT BEING APPLIED AT RIGHT ANGLES TO HINGED DOORS AND AT THE CENTER PLANE OF SLIDING OR FOLDING DOORS. COMPENSATING DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEET THE ABOVE STANDARDS. WHEN FIRE DOORS ARE REQUIRED, THE MAXIMUM EFFORT TO OPERATE THE DOOR MAY BE INCREASED NOT TO EXCEED 15 LBS. 21 REQUIRED EXIT DOORWAYS SHALL NOT BE LESS THAN 36" IN WIDTH AND NOTLESS THAN 6'-8" IN HEIGHT. FLOORS AND LEVELS 22. IN BUILDINGS AND FACILITIES, FLOORS OF A GIVEN STORY SHALL BEA COMMON LEVEL THROUGHOUT, OR SHALL BE CONNECTED BY PEDESTRIAN RAMPS, PASSENGER ELEVATORS, OR SPECIALACCESS LIFTS. STAIRWAYS(SEE CBC SEC. 11133.B.4) 23. HANDRAIL ENDS SHALL BE RETURNED OR SHALL TERMINATE IN NEWEL POSTS OR SAFETY TERMINALS 24 THE UPPER APPROACH AND THE LOWER TREAD OF EACH INTERIOR STAIR SHALL BE MARKED BY A STRIP OF CLEARLY CONTRASTING COLOR AT LEAST 2 INCHES WIDE AND PLACED PARALLEL TO AND NOT MORE THAN 1 INCH FROM THE NOSE OF THE STEP OR LANDING TO ALERTTHE VISUALLY IMPAIRED. THE STRIP SHALL BE OF A MATERIAL THAT IS ATLEAST AS SLIP RESISTANT AS THE OTHER TREADS OF THE STAIR. A PAINTED STRIP SHALL BE ACCEPTABLE. 25. WHERE STAIRWAYS OCCUR OUTSIDE A BUILDING, THE UPPERAPPROACH AN DALL TREADS SHALL BE MARKED BY A STRIP OF CLEARLY CONTRASTING COLOR AT LEAST 2 INCHES WIDE AND PLACED PARALLEL TO AND MOT MORE THAN 1 INCH FROM THE NOSE OF THE STEP OR LANDING TO ALERT THE VISUALLY IMPAIRED. THE STRIP SHALL BE OF A MATERIAL THAT IS AT LEAST AS SLIP RESISTANT AS THE OTHER TREADS OF THE STAIR. A PAINTED STRIP SHALL BE ACCEPTABLE. 26. ALL SURFACES SHALL BE SLIP RESISTANT. 27. TREADS SHALL HAVE SMOOTH, ROUND, OR CHAMFERED EXPOSED EDGES, AND NO ABRUPT EDGES AT THE NOSING (LOWER FRONT EDGE). - 28. NOSING SHALL NOT PROJECT MORE THAN 1-112 INCH PAST THE FACE OF TI-IE RISER BELOW. TOILET ROOM FIXTURES AND ACCESSORIES (SEE CBC SEC. 1115.B) 29. TOILET FLUSH CONTROLS SHALL BE OPERABLE WITH ONE HAND, AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. CONTROLS FOR TI-IE FLUSH DESIGN VALVES SHALL BE MOUNTED ON THE WIDE SIDE OF THE TOILET AREAS, NO MORE THAN 44 INCHES ABOVE THE FLOOR. THE FORCE REQUIRED TO ACTIVAQTE CONTROLS SHALL BE NO GREATER THAN 5 POUNDS. 30. HOT WATERAND DRAIN PIPES UNDER LAVATORIES SHALL BE INSULATED OR OTHERWISE COVERED. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES. 31. FAUCET CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 LBS. LEVER-OPERATED, PUSH-TYPE AND ELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGNS. SELF-CLOSING VALVES ARE ALLOWED IF THE FAUCET REMAINS OPEN FOR AT LEAST 10 SECONDS 32. GRAB BARS. TUB AND SHOWER SEATS. FASTENERS AND MOUNTING DEVICES SHALL BE DESIGNED FOR 250 LBS. PER LINEAR FOOT LOAD. GRAB BARS (SEE CBC SEC. 1115.B.7) 33. THE DIAMETER OR WIDTH OF THE GRIPPING SURFACES OF A GRAB BAR SHALL BE 1-1/4 INCHES TO 1-1/2 INCHES OR THE SHAPE SHALL PROVIDE AN EQUIVALENT GRIPPING SURFACE . 34. IF THE GRAB BARS ARE MOUNTEDADJACENTTO A WALL, THE SPACE BETWEENTHE WALLAND THE GRAB BARS SHALL BE 1-1/2 INCHES . 35. A GRAB BAR AND WALL OR OTHER SURFACE ADJACENTTO IT SHALL BE FREE OF ANY SHARP OR ABRASIVE ELEMENTS. 36. GRAB BARS SHALL NOT ROTATE WITHIN TI-IEIR FITTINGS . 37. EDGES SHALL HAVE A MINIMUM RADIUS OF 1/B INCH DRINKING FOUNTAINS (SEE CBC SEC. 11158.4.6) 3B. THE DRINKING FOUNTAIN SHALL BEA MINIMUM OF 18 INCHES IN DEPTH AND THERE SHALL BE CLEAR AND UNOBSTRUCTED KNEE SPACE UNDER THE DRINKING FOUNTAIN NOT LESS THAN 27 INCHES IN HEIGHT AND 8 INCHES IN DEPTH, THE DEPTH MEASUREMENT BEING TAKEN FROM THE FRONT EDGE OF THE FOUNTAIN. ADDITIONALLYTHERE SHALL BE TOE CLEARANCE OF 9 INCHES IN HEIGHT ABOVE THE FLOOR, AND 17 INCHES IN DEPTH FROM THE FRONT EDGE OF THE FOUNTAIN. A SIDE APPROACH DRINKING FOUNTAIN IS NOT ACCEPTABLE. 39. THE BUBBLER SHALL BE ACTIVATED BY A CONTROL WHICH IS EASILY OPERATED BY A DISABLED PERSON SUCH AS A HAND OPERATED LEVER TYPE CONTROL LOCATEDWITHIN 6 INCHES OF THE FROM=NT OF THE DRIKING FOUNTAIN AND SHALL BE WITHIN 36 INCHES OFTHE FLOOR. THE WATER STREAM FROM THE BUBBLER SHALL BE SUBSTANTIALLY PARALLEL TO THE FRONT EDGE OF THE DRINKING FOUNTAIN. ELEVATORS (SEE CBC SEC. 11168) 40. ELEVATORS SHALL BE SELF-LEVELING, 112" TOLERANCE, MAX. 41. AUTOMATIC, POWER OPERATED, HORIZONTAL SLIDING CAR AND HOISTWAY DOORS SHALL BE PROVIDED. 42. DOOR WIDTH SHALL BE 36" CLEAR, MIN. (SEE CODE FOR EXCEPTIONS) 43. CAR SIZE: 68" X 54" MIN. EXCLUDING RETURN PANELS. MNIMUM DISTANCE BETWEEN WALL AND RETURN PANEL SHALL BEE 51". 44. FLOOR BUTTONS SHALL BE WITHIN 4'·6" OF THE FLOOR. EXCEPT FOR THE PHOTO ELECTRIC TUBE BYPASS SWITCH. EMERGENCY CONTROLS SHALL BE GROUPED IN ONE LOCATION IN ORADJACENTTO THE BOTTOM OF THE PANEL AND NO LOWER THAN 2'·11" FROM THE FLOOR. FOR MULTIPLE CONTROLS, ONE SET MUST COMPLY WITH THE HEIGHT REQUIREMENTS. THE EMERGENCY TELEPHONE SHALL BE POSITIONED AT 4'-0" MAX ABOVE THE FLOOR WITHA2'-5" MIN CORD. 45. CAR CONTROL BUTTONS SHALL BE 314" MIN. IN SIZE, EXCLUSIVE OF BORDER. VISUAL INDICATION SHALL BE PROVIDED TO SHOW EACH CALL REGISTERED AND EXTINGUISHED WHEN CALL IS ANSWERED 46. A HANDRAIL IS REQUIRED ON ONE WALL OF THE CAR, PREFERABLYTHE REAR. THE BAR SHALL BE 1-112" MIN CLEAR FROM THE WALL AND 32" (+/-1") ABOVE THE FLOOR. 47. A VISUALANDAUDIBLE SIGNAL SHALL BE PROVIDED AT EACH HOISTWAY INDICATING THE CAR ANSWERING THE CALL AND THE DIRECTION OF TRAVEL. VISUAL SIGNALS SHALL BE 2-112" X 2-112" MIN. AUDIBLE SIGNALS SHALL SOUND ONCE FOR UP, TWICE FOR DOWN. THE CENTER LINE OF THE SIGNALING FIXTURE SHALL BE A MIN OF 72" FROM THE LOBBY FLOOR 48. ELEVATOR LANDING JAMBS SHALL HAVE TI-IE NUMBER OF THE FLOOR ON WHICH THE JAMB IS LOCATED DESIGNATED BY A 2" MIN ARABIC NUMERAL AND A RAISED BRAILLE SYMBOL AT THE HEIGHT OF 5'-0" ABOVE THE FLOOR ONA CONTRASTING BACKGROUND AND ON BOTH SIDES OF THE DOOR. RAISED BRAILLE SYMBOLS SHALL BE DIRECTLYTO THE LEFT OF THE ARABIC SYMBOL 49. PASSENGER ELEVATORS SHALL BE LOCATED NEAR A MAJOR PATH OF TRAVEL AND SHALL REMAIN ACCESSIBLE AND USEABLEATALL TIMES THE BUILDING IS OCCUPIED. PUBLIC TELEPHONES (SEE CBC SEC.11178.2) 50. THE CORD FROM THE TELEPHONE TO THE HANDSET SHALL BE AT LEAST 29 INCHES LONG. (SEC 11178.2.11) 51. TELEPHONES SHALL BE EQUIPPED WITH A RECIEVER THAT GENERATES A MAGNETIC FIELD IN THE AREA OF THE RE Cl EVER CAP. IF BANKS OF PUBLIC TELEPHONES ARE PROVIDED, THEN AT LEAST ONE IN EACH BANK ANDA TOTAL OF AT LEAST 25% OF THE TOTAL NUMBER OF PUBLIC PHONES IN A BUILDING OR FACILITY SHALL BE EQUIPPED WITHA VOLUME CONTROL (SEC 1117B.2.8) 52. TELEPHONES SHALL HAVE PUSH BUTTON CONTROLS WHERE SERVICE FOR SUCH EQUIPMENT IS AVAILABLE (SEC 11178.2.10) 53. TELEPHONES MOUNTED MOUNTED DIAGONALLY IN A CORNER THAT REQUIRE WHEELCHAIR USERS TO REACH DIAGONALLY SHALL HAVE HIGHEST OPERABLE PART NO HIGHER THAN 54" ABOVE THE FLOOR (SEC 11178.2.6 & FIG 118-4) 54. THE HIGHEST OPERABLE PART OF THE TELEPHONE SHALL BE WITHIN THE REACH RANGES IN SEC 11188.5 AND 11188.6 (SEC 11178.2.6 &FIG 118-4) 55. BASES, ENCLOSURES AND FIXED SEATS SHALL NOT IMPEDE APPROACHES TO TELEPHONES BY PEOPLE WHO USE WHEELCHAIRS (SEC111782.5) ADDITIONAL REQUIREMENTS 56. THE CENTER OF THE RECEPTACLE OUTLETS SHALL NOT BE LESS THAN 16 INCHES ABOVE THE FLOOR OR WORKING PLATFORM. 57. THE CENTER OF THE GRIP OF THE OPERATING HANDLE OF SWITCHES INTENDED TO BE USED BY THE OCCUPANT OF THE ROOM OR AREA TO CONTROL LIGHTING AND RECEPTACLE OUTLETS.APPLIANCES OR COOLING, HEATING.AND VENTILATING EQUIPMENT SHALL NOT BE LESS THAN 3 FEET NOR MORE THAN 4 FEET ABOVE THE FLOOR OR WORKING PLATFORM. 5B. THE CENTER OF THE FIRE ALARM INITATING DEVICES (BOXES) SHALL BE LOCATED 48 INCHESABOVE THE LEVEL OF THE FLOOR, WORKING PLATFORM, GROUND SURFACE, OR SIDEWALK. 59. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE THE STANDARD USED TO IDENTIFY FACILITIES THAT ARE ACCESSIBLE TO AND USEABLE BY PHYSICALLY DISABLED PERSONS AS SET FORTH IN THE use BUILDING STANDARDS 6D. IF EMERGENCY WARNING SYSTEMS ARE REQUIRED THAY SHALL ACTIVATE A MEANS OF WARNING THE HEARING IMPAIRED. FLASHING VISUAL WARNINGS SHALL HAVE A FREQUENCY OF NOT MORE HTAN 3 FLASHES PER SECOND AND SHOULD NOT BE SLOWER THAN 1 FLASH PER SECOND. © SD DESIGN STUDIO, LLC & RUSH CREATIVE STUDIO ~SESSIONS WEST COAST DELI AT FASHION ISLAND (MACY'S} INTERIOR REMODEL T.I. 401 NEWPORT CENTER DR . SUITE lOlX, FASHION ISLAND NEWPORT BEACH, CA 92660 0'.2: 0 '.2: _J 0 0 _J 0 0 0 o~o ::) 0 f-0 00 (/) :::i :::i I- ::, I-Ll.J U) I-U) > Lr.J > C/) z I-Cl f-<i: z-<( Lr.J U) a: CJ Lr.J Ll.J 0 -o 0::: I C/) 0 0 U) LJJ 1/l :::i I a: 0~ (/) 3 03 :) 3 C/) 3 Cl:'. 3 s DD s ~ -,~ . ' : ,, . Num Descnption Date DATE: 8/20/19 SCALE: AS NOTED SDDS & RUSH CS PROJECT NUMBER: 1906 ACCESSIBILITY NOTES AND TYP. DETAILS SP1 PA2019-141 ZONING ADMINISTRATOR 10/10/2019 - APPROVED (8 PAGES) '----SESSIONS DELI ( SCOPE OF WORK ) SITE PLAN PLAN NOTES THIS PROJECT SHALL COMPLY WITH ALL CURRENT REQUIREMENTS OF THE STATE PERMIT; CALIFORNIA REGIONAL WATER QUALITY CONTROL BOARD ( SDRWQCB ), SAN DIEGO MUNICIPAL STORM WATER PERMIT. THE CITY OF SAN DIEGO LAND DEVELOPMENT CONE, AND THE STORM WATER STANDARDS MANUAL. NOTES BELOW REPRESENT KEY MINIMUM REQUIREMENTS FOR CONSTRUCTION BMP's 1 THE CONTRACTOR SHALL BE RESPONSIBLE FOR CLEANUP OF ALL SILT & MUD ON ADJACENT STREET(S), DUE TO CONSTRUCTION VEHICLES OR ANY OTHER CONSTRUCTION ACTIVITY, AT THE END OF EACH WORK DA'!'. OR AFTER A STORM EVENT THAT CAUSES A BREECH IN INSTALLED CONSTRUCTION BMP'S WHICH MAY COMPROMISE STORM WATER QUALITY WITHIN ANY STREET(S). A STABILIZED CONSTRUCTION EXIT MY BE REQUIRED TO PREVENT CONSTRUCTION VEHICLES OR EQUIPMENT FROM TRACKING MUD OR SILT ONTO THE STREET. 2. ALL STOCKPILES OF SOIL &/OR BUILDING MATERIALS THAT ARE INTENDED TO BE LEFT FOR A PERIOD GREATER THAN 7 CALENDAR DAYS ARE TO BE COVERED. ALL REMOVABLE BMP DEVICES SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN 5 DAY RAIN PROBABILITY FORECAST EXCEEDS 40%. 3. A CONCRETE WASHOUT SHALL BE PROVIDED ON ALL PROJECTS WHICH PROPOSE THE CONSTRUCTION OF AN CONCRETE IMPROVEMENTS WHICH ARE TO BE POURED IN PLACE ON SITE. 4. THE CONTRACTOR SHALL RESTORE ALL EROSION/ SEDIMENT CONTROL DEVICES TO WORKING ORDER AFTER EACH RUN-OFF PRODUCING RAINFALL OR AFTER ANY MATERIAL BEACH IN EFFECTIVENESS. 5. ALL SLOPES THAT ARE CREATED OR DISTURBED BY CONSTRUCTION ACTIVITY MUST BE PROTECTED AGAINST EROSION AND SEDIMENTTRANSPORT AT ALL TIMES. 6. THE STORAGE OF ALL CONSTRUCTION MATERIALS AND EQUIPMENT MUST BE PROTECTED AGAINST ANY POTENTIAL RELEASE OF POLLUTANTS INTO THE ENVIRONMENT. © SO DESIGN STUDIO, LLC & RUSH CREATIVE STUDIO 'sfss1of,fs WEST m=r,&, COAST DELI AT FASHION ISLAND (MACY'S) INTERIOR REMODEL T.I. 401 NEWPORT CENTER DR. SUITE IOJX, FASHION ISLAND NEWPORT BEACH, CA 92660 () ~ ...J 0 ...Ju 60 00 ::::, ::::::, I- I-en (./') z CJ z-en CJ w -o (./') 0 UJ en 0~ 03: (./') 3: 0 ::r 0 (.) ::> 0 I-Q C/) ::::, 1-w en w > > I-~ <( w er: IJ.J 0 0:: :c () en ::::, er: 3: 3: 3: s DD -s Num Description Date DATE: SCALE: 8/22/19 AS NOTED SDDS & RUSH CS PROJECT NUMBER: 1906 SITE PLAN A1 PA2019-141 ZONING ADMINISTRATOR 10/10/2019 - APPROVED (8 PAGES) FINISH PLAN SCALE: 1/4"=1'-0" MATERIAL FINISH SCHEDULE I I I I I __ --I 1..----------------------0 / FINISH .... ,-----71 \ I I I I / I '/ I I \ I I \ I \ I \ I \ I 0 ~ 0 0 0 0 SANDED AND SEALED (l=OODGRADE) 0 SERVICE AREA 102 0 0 0 0 0 REFLECTED CEILING PLAN SCALE: 114"=1'-0" KITCHEN 104 0 LEGEND 0 [SI IZI L-1 RECESSED DOWN LIGHT FLUSH MOUNT PENDANT LIGHT FIXTURE SUSPENDED WI SWIVEL BASE L-3 RECESSED WALL WASHER FLUSH MOUNT SUPPLY AIR DIFFUSER FLUSH MOUNT -GYP. BOARD RETURN AIR FLUSH MOUNT -GYP. BOARD FIRE SPRINKLER FLUSH MOUNT -GYP. BOARD PLAN NOTES 1. AL NEW CONSTRUCTION TO MEET ADA REQUIREMENTS. 2. INTERIOR DESIGNER NOT RESPONSIBLE FOR ANY STRUCTURAL ENGINEERING. GENERAL CONTRACTOR TO CONTRACT OUT WITH APPROPRIATE SUB -CONTRACTORS IN ORDER TO IMPLEMENT DESIGNS AS PER DRAWINGS. 3. CONTRACTOR TO VERIFY EXISTING DIMENSIONS AND CONDITIONS IN FIELD PRIOR TO ORDERING MATERIALS AND FIXTURES. 4. CONTRACTOR TO VERIFY LOAD REQUIREMENTS AGAINST WEIGHT OF ALL NEW FIXTURES AND CEILING TREATMENTS. 5. PATCH & REPAIR CEILING WHERE NEEDED. 6_ FINAL MOUNT HEIGHT FOR ALL SUSPENDED FIXTURES TO BE VERIFIED WITH DESIGNER. 7. NEW JUNCTION BOXES TO BE INSTALLED FOR ALL CEILING MOUNTED LIGHT FIXTURES AS NECESSARY. KEYNOTES 1:2] ~:~l~~LL ( E ) FIRE SPRINKLERS @ AREA OF NEW RELOCATE/RAISE ( E ) MECHANICAL DUCTING & VENTS. RELOCATE ( E) CAN LIGHTING AS REQ'D LINE OF ( E ) SOFFIT EDGE PORTION OF ( E ) SOFFIT TO BE REMOVED CENTER RECESSED DOWNLIGHT(S) BETWEEN DECORATIVE BEAMS PER PLAN LINE OF ( N ) MILLWORK OR EQUIPMENT, TYP. 12 © SD DESIGN STUDIO, LLC & RUSH CREATIVE STUDIO sffiTONSWEST-~"-· COAST DELI AT FASHION ISLAND [MACY'S) INTERIOR REMODEL T.I. 401 NEWPORT CENTER DR. SUITE lOIX, FASHION ISLAND NEWPORT BEACH, CA 92660 U::e: -' 0 -' u o~o 00 ::::, :::::) I- I-(/) (./) z ('J z- (/) (.'.J LJJ -o (./) 0 UJ (/) o; 03 (./) 3 ci 0 ::) I- (/) lJJ > I- <{ UJ 0:: (.) I (/) ::) 0:: s DD s ::E 0 0 0 0 ::::, 1- (/) LJJ > 1- <t: LJJ 0: u I (/) ::::, 0: 3 3 3 Num Description Date 8/22/19 AS NOTED SODS & RUSH CS PROJECT NUMBER· 1906 FINISH PLAN/ REFLECTED CEILING/ LIGHTING PLAN A3 PA2019-141 ZONING ADMINISTRATOR 10/10/2019 - APPROVED (8 PAGES) I EGlLJIF'lVIEl"--JT Sc:::::HEDLJLE EQUIPMENT Ko2 151:T EXIST1Nt5 RELOCATED EMPLOYEE LOCKERS KOS 151:T EXISTIN5 MOP SINK STATION K04 I SET EXISTINS HALK-IN COOLER I FREEZER K05 KOb NEW TJ/'IO TIER BEER KEt5 RAC.K KELMAX / SPt5 KR-42 KOi KOb -KO'I KIO. KIi Kl2 I 51:T EXISTIN5 COOLER SHELVINt5 UNITS I -€6t~i~'m C.OIL AND C.OMPRESSOR FOR I 51:T FREEZER i"d"~WJk"J'T COIL AND C.OMPRESSOR FOR 1 SfT EXISTING FREEZER STORAGE SHELVING UNITS I ELECTRIC. VENTLE55 OVEN, RIISHT HIN5ED EXISTIN5 STAINLESS STEEL TYPE I EXHAUST HOOD KIB I EXISTIN5 EXHAUST FAN AND MAKE-UP AIR SYSTEM K14 K15 K16 K11 NEV'l 24" EL.EC.TRIC HOT TOP RANGE NEV'! 24" ELECTRIC COUNTERTOP GRIDDLE NEW 48" S/C TWO DRAV'IER REFRISERATED BASE J/'lm CASTERS NEW STAINLESS STEEL TIJElULAR WALL SHELF KIi> 2 NEW 45 L.B. ELEC.TRIC FRYERS Kl<! I SET EXISTIN5 STAINLESS S, t:EL REPLAC.E AS NEEDED K.20 NEV'! STAINLESS STEEL STAND AT PANINI GRILL 1<21 COUNTERTOP PANINI SRILL K22 ALTO SHAAM VMC-H4 1"'1PERIAL RANGE IHPA-4-.24-E IMPERIAL RANSE ITS-.24-E TRUE TRCE!-41> ADVANCE T AE!C,O DT-6R-41> IMPERIAL RANGE IFS-50-E CUSTOM STAINLESS S1t:t:1. SEE DETAIL XX-XX CUSTOM STAINLESS STEEL STAR/ HOLMAN 5Xl41X K2:3 I NEH TJ/'IO TIER STAINLESS STEEL TABLE MOUNT SHELVE= ADVANCE TAE!C,O K24 -K25 K26 NEV'! STAINLESS STEEL J/'IORKTASLE J/'IITH 16"X.20"Xl.2" BUILT-IN SINK LOCATION PER PL.AN NEH SPLASH MOUNT FAUCET NEW SHELF MOUNT MICROJ/'IAVE OVEN KW I SfT NEH TJ/'IO TIER STAINLESS STEEL TABLE MOUNT SHELVE= OPEN NUMBER IGO OPEN NUMBER IGI OPEN NUMBER JGS I EXISTINS J,,ilRE J,,IALL SHELF IG4 IG5 1<36 K3'7 K40 -K41 , EXISTING SLISHTLY RELOCATED THREE C.OMFARTMENT ' SINK ; EXISTING PRE-RINSE UNIT HITH ADD-ON FAUCET NEV'! STAINLESS STEEL SLANT RACK SHELF EXISTINS 52 SALL.ON BRUTE TRASH CAN NEV'! SPLASH MOUNT PRE-RINSE UNIT NEH STAI SINK NEW L SOILED DISHTABLE W PRE-RINSE E SC.RAP BASKET ISHHASHER 1<42 2 NEW STAINLESS STEEL PASS THRU SHELF 1<45 sirs NEW STAINLESS STEEL WALL SHELVES K44 tfu ~i'fJ'· / RELOCATED 14" DEEP FIVE TIER HIRE SHELVINS K45 I Sc"T ~~STINS-saF-CONTAINED ICE KACHINE AND ICE K46 2 EXISTINS ELECTRIC.AL PANELS 1<41 NEV'! WILL CALL/TO t50 ORDER COUNTER 1<41> 2 NEW DECORATIVE J,,IALL SHELVES K50 K51 1<52 K55 K54 K55 K56 K5'1 2 NEV'! DECORATIVE J/'IALL SHELVES NEW STAINLESS STEEL BEVERAGE COUNTER I (!;'~iHwERENCE ONLY) NEJ/'I TJ,,IO 6ROUP ESPRESSO I ~~{4" SELF-CONTAINED UNDER COUNTER REFRIG. I (FOR REFERENCE ONLY) ESPRESSO 0RINDER NEW STAINLESS STEEL KNOC.K BOX NEV'! UNDER COUNTER TRASH C.AN NEJ,,i STAINLESS STEEL DROP-IN HAND SINK W SFLA51-t5UARD SOAP AND PAPER TOV'IEL DISPENSERS NEJ,,i BACK BAR COUNTER NEJ,,i STAINLESS STEEL FRONT UNDER BAR C.OUNTER K60 I SET ~~~fjER TOV'IER AND DRAIN PAN AS SELECTED BY K61 I NEH FRONT DINING COUNTER, 4.2" HEIGHT K62 OPEN NUMBER K65 OPEN NUMBER K64 OPEN NUMBER K65 1 NEV'! ADA DINING COUNTER, 54" HEIISHT ADVANCE T AE!C,O VKS-505 / TA-IIB FISHER 601>01 AMANA ACP RCSIOTS CONTINENTAL D1.2NSOM-FS-D CONTINENTAL 00512 ADVANCE TABc.O DT-6R-l.2 FISHER 5.2'1.2.2 ADVANCE TABCO DT5-S10-60L ECOLAB OR EG!UAL E52000C. CONTINENTAL D60N.24M-FB-D CUSTOM STAINLESS STEEL SEE EGIJIP. ELEVATION ADVANCE TA6c.O 1"15-1.2-.24 / 1"15-1.2-60 CUSTOM MILLJ/'IORK SEE ARCHITECTURAL DV'IGS CUSTOM MILLJ/'IORK SEE ARCHITEC.TURAL DHGS CUSTOM MILLJ/'IORK SEE ARCHITECTURAL DV'IGS CUSTOM STAINLESS STEEL SEE EGIJIP. ELEVATIONS BUNN 211>00.oooq ElUNN 211>50.0001 LA MARZOCCO LINEA2-EE TRUE TUC-.24 LA MARZOCCO SJ/'IIFT RU66ERMAID FG2'151006LA CUSTOM MILLJ/'IORK SEE ARCHITECTURAL DV'IGS CUSTOM STAINLESS STEEL PER.LICK 400b-4T CUSTOM MILLJ/'IORK SEE ARCHITEC. TURAL DlrlGS CUSTOM MILLJ/'IORK SEE ARCHITECTURAL DV'IGS K66 I ~~~i/C. UNDER COUNTER REFRISERATED GRAS-N-eo ~~:f'.2~ CONCEPTS K61 1<10 1<11 K12 2 NEJ,,i C.ASH REGISTERS OJ/'INER PROVIDED I rir ~;!f 1NLESS STEEL UNDER COUNTER MOUNTED OPEN NUMBER OPEN NUMBER OPEN NUMBER OPEN NUMBER DELFIELD 240 PLUMBINC3 ffi ~ I-~ C 3: w 9 3: I-,_ <I) m 0 0 C ~ 0 :c 3:: .,,,.,,,,,.,..-- -,,,.,,,,,.,,, ---~,,,,- ~ ~ ,,,,,,,,~- ~,,,,,,,,..-- ~~ -~ ~ .,,,,..---~-~ ,,,,,,,,..-- ~ ~ ~ ~ ~ --~ ~ F.5. ~ ~ --~ ~ ~ ,,,,,,,,..-- ~ ,,,,,,,,..-- ,,,,,,,,..-- ,,,,,,,,..-- ~- ~ 1/.2" 1/.2" F.S. 5/4" F.S. -- ~ --1/.2" F.5. ~ ~ ~ 1/.2" F.S. ~ --1/2" H/2" ----~ F.S. ~ -- F.S. ~ m II! I EXISTING TO REMAIN EXISTING TO REMAIN EXISTINe TO REMAIN EXISTING TO REMAIN INDIRECT HASTE W I' AIR GAP AT (E) FLOOR SINK RE-USE EXIST. V'IATER LINES RE-USE EXISTINt5 PLUMBING RE-USE EXISTINe PLUMBING RE-USE EXISTING PLUMBING INDIRECT HASTE WITH I" AIR GAP AT FLOOR SINK INDIRECT J,,!ASTE J/'IITH I" AIR 6AP AT FLOOR SINK EXISTINS TO REMAIN CONNECT TO J,,IATER FILTER C,ONNECT TO J,,IATER FILTER IND. WASTE TO (E) FLR. SIN~ INDIRECT J,,!ASTE WITH I" AIR GAP AT (E) FLR. SINK DIREC. T V'IASTE INDIRECT J,,!ASTE V'IITH I" AIR 6AP AT (E) FLR. SINK INDIRECT WASTE V'IITH I" AIR GAP AT /E) FLR. SINK ELECTRICAL ffi 3: i ~ rn in w (IJ d t C a: :c 0 > C ... :c 120 15.1 I 1/:3 .2oe, 55.0 5 20b .2'1.0 5 20b 2'1.0 5 1.20 5.4 I 1/5 201> 45.0 5 20b 10.1 I 1.20 4.0 I 1.20 10.0 I 1.20 6.1 I 1/5 1.20 16.0 I I 120 5.e I 1/:3 120 6.0 I 120 b.O I 1.20 17.5 I 201> .2.2.0 I 120 2.0 I 1/6 1.20 I s.o I 1.20 6.0 I 1.20 6.0 I 1.20 1.2.0 1.20 4.0 m II! C ~ a: EXISTING TO REMAIN ~'fj_~~DUIT CONNEC.TIO~ EXISTING TO REMAIN EXISTING TO l'!l:MAIN WITH NEMA 5-15P CORD AND PLUG REG. 40 AMP CIR. EXISTINe MECHANICAL AND ELEC.TRICAL TO REMAIN EXISTli'IG MECHANICAL AND ELECTRIC.AL TO REMAIN FLEX CONPLIIT CONNECTION TO J-BOX FLEX CONPUIT CONNECTION TO J-BOX V'IITH NEMA 5-15P CORD AND PLUc5 45.0 AMPS PER FRYER FLEX CONDUIT CONNECTION V'IITH NEMA 5-15P C.ORD AND PLUc5 RECONNECT TO SHUNT TRIP AT ELECTRICAL PANEL WITH NEMA 5-15P CORD AND FLUG V'IITH NEMA 5-15P CORD AND PLUG FLEX CONDUIT CONNECTION TO J-BOX V'IITH NEMA 5-15P CORD AND PL.Ut5 EXISTINi=< TO REMAIN EXISTING TO REMAIN CONVENIENCE OUTLET C.ONVENIENC.E OUTLET J/'IITH NEMA 5-15P CORD AND PLUG J/'IITH NEMA 6-:lOP CORD AND PLUG J,,IITH NEMA 5-15P CORD AND PLUG J,,IITH NEMA 5-15P CORD AND PLUG CONVENIENCE OUTLET (4) CONVENIENCE OUTLETS (2) PER EAC.H SIDE REG. DEDICATED OUTLETS AND CIRCUITS I i)(i [~' :n1•:,(E) I /';•, '.:,~(~;--~~-- ~1 / / 1 l"-'2''·'"''-------;;c=~M c·.i (E) (E) (E) ,i r.l;, I 1 r .. "/ / ~--.\-.,;-J~ / ~~II /J/ //~ Qt; f-BE! /}; ·~·>> ~, "M ~: 20 [ill ""'1 -~.~~::~~ 26 27 26 == f-,-----7i \ I I \ I I \ I I '/ I I \ I I \ I I \ I I \ I I \ I ,--------'>: I I I /rB a ~=-mm_. -,__-·-_--_--·_----·~-· · .. • ~-·~:-~7-~~::::~oo~,.,..,. .. ~ .. .'111-;f§t_;g_'~-·~-7 -(2..,____, rt-c::::------: '·>·,:; /1 I /~'~ I /~: J ~1 : / ) I ..... /! I I , ! EQUIPMENT PLAN SCALE: 1/4"=1'-0" I I I I I ' 17480 VF 0'------j:I ======-1° ~T 2: © SD DESIGN STUDIO, LLC & RUSH CREATIVE STUDIO - - SESSIONS WEST COAST DELI AT FASHION ISLAND (MACY'S) INTERIOR REMODEL T.I. 401 NEWPORT CENTER DR. SUITE 101 X, FASHION ISLAND NEWPORT BEACH, CA 92660 (_) ~ 0 ~ JO 0 _J 0 0 (.) 60 :::::, 0 I-0 00 (./) :J ::::i I- ::> I-LLJ Cll lJ.J I-en > > (/) z I-0 I-<( z-<( lJ.J en 0:: (.'.J w LLJ (.) -o 0::: :c (/) 0 (.) en Wen :J I 0:: o; (./) 3 03 ::) 3 (/) 3 0::: 3 s DD s 9P ~ . ' . Num De:saiptian DATE: 8/22/19 Dale SCALE: AS NOTED SODS & RUSH CS PROJECT NUMBER: 19D6 EQUIPMENT PLAN / EQUIPMENT SCHEDULE A4 PA2019-141 ZONING ADMINISTRATOR 10/10/2019 - APPROVED (8 PAGES) ====:::j MATERIAL FINISH SCHEDULE 4•~. FINISH MAR< rlalltriod. StainlN1 Steel, Type 30<4, 314 #9 Flattened. 6&% O~&n Area ~~ TYP. ~~--- "' WO 2 ~ SANDED AND SEA.LED (FOOD GRADE) ? / / PEWTE~(62) ?i TYP. I I -. =---I -~--0 .;. I i I • ~TYP. © ~ CUT , -~/ l_1 .,J KEYNOTES ALL SIDES OF WINDOW OPENING UNDER COUNTER REFRIGERATOR -VERIFY WI SPEC SHEETS FOR DIMENSIONS OF COUNTER OPENINGS { E) WALL TILE TO BE REMOVED, PATCH & REPAIR STUCCO/ PAINT. ( N ) 49" WALL MOUNTED TV/ SAMSUNG-MODEL: 77 © SD DESIGN STUDIO, LLC & RUSH CREATIVE STUDIO SESSIONS WEsr••u"-"" COAST DELI AT FASHION ISLAND (MACY'S) INTERIOR REMODEL T.I. 401 NEWPORT CENTER DR. SUITE 101X, FASHION ISLAND NEWPORT BEACH, CA 92660 u :l'. _J 0 _Ju 60 00 ::, :::::, I- I-(J) CJ) z CJ z- (J) ('.J LJ.J -o CJ) 0 w(J) 0~ 03: CJ) 3: 0 0 :::> 1- (/) UJ > I- <( UJ 0:: (_) I (/) :::> 0:: s DD s Num Oasaiptlon SCALE: ::E 0 u 0 0 ::, 1- (J) LJ.J > I- ~ LJ.J 0:: u I (J) ::, 0:: 3: 3: 3 Date DATE: 8/21/19 AS NOTED SODS & RUSH CS PROJECT NUMBER: 1906 INTERIOR ELEVATIONS AS PA2019-141 ZONING ADMINISTRATOR 10/10/2019 - APPROVED (8 PAGES) CSLT 1 [iJ ~ ALL MATERIAL FINISH SCHEDULE FINl!IH MARK Fla~enad, S!a,nlut SIMI. Typa 304, 314 #9 Ftatlened, 66o/o Op.nn Ar11~ 5ANOEDANDSEALED (FOODGRADE) © SD DESIGN STUDIO. LLC & RUSH CREATIVE STUDIO sEss10NswEs('·· COAST DELI AT FASHION ISLAND (MACY'S) INTERIOR REMODEL T.I. 401 NEWPORT CENTER DR. SUITE lOIX, FASHION ISLAND NEWPORT BEACH, CA 92660 u~ _J 0 _Ju Qo 00 :::J ::::> I- I-(/) U) z (!) z- (/) <.'.Jw -o U) 0 Ll.J (/) o; 03 U) 3 Cl :::J I- (/) LJ.J > I- <( LJ.J c::: 0 I (/) :::J c::: s DD s ~ 0 (.) 0 0 :::J I-- Cf) w > I- <{ w 0:: (.) :c en :::J 0:: 3 3 3 Num DescripUon Date DATE: 8/21/19 SCALE: AS NOTED SDDS & RUSH CS PROJECT NUMBER: 1906 INTERIOR ELEVATIONS A6 PA2019-141 ZONING ADMINISTRATOR 10/10/2019 - APPROVED (8 PAGES) ~ / ' NO. SIZE TYPE HDWR. GROUP ( 1) 3668 B - < 2) 3058 A 2 HARDWARE GROUPS : 1. LATCH 2. LATCH WITH PRIVACY LOCK NO. SIZE TYPE MATERIAL / [j " ' ' FINISH FACTORY FACTORY DOOR NOTES: ' " ..., ' co / / / ® METAL FRAMED GLASS DR. ( W/ SINGLE LITE) DOOR SCHEDULE DETAILS HEAD JAMB THRESH --- - - - 1 VERIFY ALL SIZES & STYLES W/ SD DESIGN STUDIO A METAL FRAMED VERTICAL FOLDING WINDOW ( 2 • FOLDING PANELS) WINDOW SCHEDULE FINISH SWING DETAILS INTERIOR EXTERIOR HEAD JAMB (1) 17480 A FACTORY FACTORY FACTORY (2) 7580 A FACTORY FACTORY FACTORY WINDOW NOTES : 1 ALL GLAZING TO BE DUAL PANE LOW-E. 2. VERIFY ALL SIZES & STYLES WI SD DESIGN STUDIO FLOOl-?UNE ,I,. ~ NOTES TEMPERED FLOOR LINE NOTES SILL MATERIAL FINISH SCHEDULE FINISH MARK flatt~ned,Slai,11nsSleol,Type304,3/4.lt9Flatteoed,G6%0ponAre11 .---, ----,----------------;,-------,-------------. ------------- ·: ;: I : :1 0 l f------- SANDED ANO SEALED (FOOD GRADE) KEYNOTES ALL SIDES OF WINDOW OPENING UNDER COUNTER REFRIGERATOR-VERIFY WI SPEC SHEETS FOR DIMENSIONS OF COUNTER OPENINGS ( E) WALL TILE TO BE REMOVED, PATCH & REPAIR STUCCO I PAINT. ( N ) 49" WALL MOUNTED TV/ SAMSUNG -MODEL: ?? © SD DESIGN STUDIO, LLC & RUSH CREATIVE STUDIO rfssi0Nsw1:sr~-✓4U COAST DELI AT FASHION ISLAND (MACY'S) INTERIOR REMODEL T.I. 401 NEWPORT CENTER DR. SUITE lOIX, FASHION ISLAND NEWPORT BEACH, CA 92660 -- (.)::e: 0 2 ......J 0 0 ......J 0 0 0 o~o :::> 0 I-0 00 (/) :::i :::i I- :::, I-w u, LJ.J I-U) > > en z I-('J I-<( z-<( LJ.J (fl 0:: (9 UJ w 0 -o 0::: J: Cf) 0 0 u, UJ (fl :::i I 0:: o; Cl) 3 03 :::> 3 (/) 3 0::: 3 s DD s Num Description Dale DATE: 8/21/19 SCALE: AS NOTED SODS & RUSH CS PROJECT NUMBER: 1906 EXTERIOR ELEVATIONS/ DOOR & WINDOW SCHEDULE A7 PA2019-141 ZONING ADMINISTRATOR 10/10/2019 - APPROVED (8 PAGES)