HomeMy WebLinkAbout20210524_Plans_24x36PA2021-118 PA2021-118 FINISHES: FLOOR COVERING: Type 1:1/8" V.C.T. Tile to be 50% OFFSET. Location: (RESTROOMS ONLY) Color to be: (FORTRESS WHITE) Type 2:26 oz. carpet. Location: (REMAINDER) Color to be: (RITZ BLITS 66764) BASE: Cove Base 1 :4" Vinyl cove. Location: (THRU-OUT) Color to be: (BROWN 47) WALLS: Covering 1:1/2" VINYL TACKBOARD (CHATFIELD CLARKE GROUP 1 TYPE 1) over 1/2" raw gypsum. VCG only on Corridor 105 side and Office 106 side of walls. Location: (CLASSROOMS ONLY) - see hatch Covering height: 8' Color to be: (SNOWBANK). Covering 2:1/2" vinyl covered gypsum Location: (REMAINDER) Covering height: 8' Color to be: (TIKI GRASS CHALK). Covering 3:Standard FRP panels (per code) Location: (Restrooms) Covering height: 4' Color: (White) TRIM: Wall Trim 1:Vinyl Covered batt strips at all tackboard seams (Classrooms only) Color to be: (SNOWBANK) Wall Trim 2:Vinyl Covered trim Color to be: (To match VCG) CEILING: Type 1:2'x4' HEAVY DUTY T-Grid w/ Struts & wires (Armstrong Tile #769A or Equal) Height: 7'-10" Installed at factory, held back at module lines. Completion of ceiling installation on-site by others; not in PMI's scope. EXTERIOR Siding body:Color: (BEHR BENNINGTON GRAY) 8' sheets Hood:Color: (BEHR MIDSUMMER NIGHT) Corner trim:Color: (BEHR MIDSUMMER NIGHT) Door & window trim: Color: (BEHR MIDSUMMER NIGHT) Bottom horizontal trim: Color: (BEHR MIDSUMMER NIGHT) Intermediate horizontal trim: Color: (BEHR MIDSUMMER NIGHT) separates hood & body Top horizontal trim:Color: (BEHR MIDSUMMER NIGHT) Module line trim:Color: (Match hood above intermediate horizontal trim & match body below) All paint to be:COLOR MATCH WITH GLIDDEN (Satin Finish) INTERIOR WALL CONSTRUCTION: Framing: Stud:2X4 #2 HF equal or better @ 16" O.C. Top plate: Single 2X4 #2 HF equal or better (Double as needed) Bottom plate: Single 2X4 #2 HF or better bottom plate Stud length: 92-5/8" (Ceiling Ht.) Insulation: R-11 unfaced battens (at Classroom walls only - see hatch) (Ceiling Ht.) Additional Interior Wall Items Included in Quoted Price: Item 1: Full height walls (to rafters) between classrooms only for sound control. Item 2: See Post Detail 4/2 for Post #3. FRAME / CHASSIS: Frame Type: Basement (CH2) Quantity:(3) EA Size:11'-8" X 60'-0" Type:Outrigger @ 96" O.C. Crossmember @ 96" O.C. Module line Clips @ 96" O.C. Main Rails @ 99 1/2" O.C. Beam Size: 12" Jr. I-beam Axles: Module 1: Qty: Five 6000# rated with (All) brake Offset: 4" (Toward sidewall) See Detail 1/1 Module 2: Qty: Quad 6000# rated with (All) brake Offset: None Module 3: Qty: Quad 6000# rated with (All) brake Offset: 4" (Toward sidewall) See Detail 1/1 Hitch:Detachable with Standard Hitch Tires:8x14.5 14 ply rated Additional Frame / Chassis Items Included in Quoted Price: Item 1: None FLOOR CONSTRUCTION: Floor Joist:2X8 #2 HF equal or better Joist Length: 133-7/8" Joist Spacing: 16" O.C. Floor: Single layer 3/4" T&G Plywood. Insulation:R-19 unfaced fiberglass batt Bottom: Reinforced Plastic Additional Floor Items Included in Quoted Price: Item 1:N/A EXTERIOR WALL CONSTRUCTION: Framing:Stud:2X4 #2 HF equal or better @ 16" O.C. Top Plate: Double 2X4 #2 HF equal or better Bottom Plate: Single 2X4 #2 HF or better Header: (2) 2x4 header with (1) 1/2" shim at all exterior openings (UNO) Insulation: R-13 Kraft back fiberglass batt Siding Type: 3/8" LP Smart-panel vertical siding (8" grooves) with barricade wrap underlayment. Sidewall Height: See cross section for heights ROOF CONSTRUCTION: Roof Type: Complex Roof Slope: 1/4 in 12 Rafter size: 2X8 #2 HF equal or better (Roof diaphragm chord strap 'ST2215' at rafters installed on-site, see 5/2) Rafter Length: MOD 1 & 3: 135 1/2" MOD 2: 134" Spacing:16". O.C. Mate Beam: Multi-layer plywood Height:20" to 27 1/2" to 20" Length: 60' No. of Layers: 3 No. of Beams: 4 Insulation: R-19 unfaced fiberglass batt with support netting Sheathing: 1/2" 24/0 Sheathing Roofing:45 mil single ply EPDM over 1/2" Gypsum Color: White Additional Roof Items Included in Quoted Price: Item 1: N/A EXTERIOR/INTERIOR DOORS:(SEE DOOR SCHEDULE) WINDOWS:(SEE WINDOW SCHEDULE) CLOSEUP: Type:Medium Notes:Module WILL NOT exceed 12'-0" (Except door hardware) APPLIANCES: None provided ACCESSORIES: None provided SKIRTING: None provided VARIESGRADE FLOOR JOIST ML EXTERIOR WALL (SIDEWALL) MAIN RAIL (I-BEAM) 24 1/4"99 1/2"16 1/4" 11'-8" FLOOR WIDTH OUTRIGGER OUTRIGGER TYPICAL OFFSET TOWARDS SIDEWALL DEALER: MOBILE MODULAR PROJECT: NEWPORT BEACH CLASSROOM 36 X 60 PMI-4943-3660 DRAWING INDEX SHEET 1: SPECIFICATIONS AND CONDITIONS SHEET 2: FLOOR PLAN, STRUCTURAL LEGEND, DOOR, WINDOW, PLUMBING SCHEDULES, PLUMBING FIXTURE DETAILS SHEET 3: ELECTRICAL PLAN, ELECTRICAL SCHEDULE, ELECTRICAL CALCS AND ELECTRICAL NOTES SHEET 4: REFLECTED CEILING PLAN, DETAILS, PLUMBING SCHEMATICS SHEET 5: HVAC PLAN, HVAC SCHEDULE SHEET 6: EXTERIOR ELEVATIONS, BUILDING CROSS-SECTION "PLEASE REVIEW DRAWINGS AND SPECIFICATIONS CAREFULLY. WHILE EVERY EFFORT IS MADE TO ASSURE THE DRAWINGS REFLECT THE EXPECTATIONS AND QUOTATION, THE FINAL CONSTRUCTION WILL BE BASED SOLELY ON THE SPECIFICATIONS AND DRAWINGS APPROVED." APPROVED APPROVED EXCEPT AS NOTED REVISE AND RESUBMIT BY:DATE: DATA PLATE AND STATE DECAL TO BE LOCATED ON LOWER RIGHT HAND CORNER OF THE ENDWALL OPPOSITE THE HITCH END OF THE MODULE. SPRINKLERS REQUIRED. NO INSTALLED AT.N/A CONTRACTED BY.N/A INSTALLED BY.N/A SPECIAL CONDITIONS AND OR LIMITATIONS: IDENTIFICATION: NOTES: 1 1. SITE PLAN NOT AVAILABLE AT THIS TIME. BUILDING DESIGNED TO HAVE FIRE SEPARATION DISTANCE GREATER THAN 10 FT. TO PROPERTY LINES AS PER LOCAL BUILDING DEPARTMENT REQUIREMENTS. 2. THIS PLAN MAY BE REVERSED AND/OR MIRRORED. 3. SEE STRUCTURAL PACKAGE FOR ALL STRUCTURAL STANDARDS AND DETAILS. 4. COMPLIANCE WITH HCD IGNITION RESISTANT CONSTRUCTION SYSTEM REQUIREMENTS? (CBC CHAPTER 7A) NO . 5.TO BE INSTALLED ON A PERMANENT FOUNDATION? NO . 6. THIS BUILDING IS DESIGNED TO COMPLY WITH THE COMMERCIAL MODULAR REQUIREMENTS OF CALIFORNIA CODE OF REGULATIONS TITLE 25. MANUFACTURER: DESIGN CRITERIA / LOADS: NOT INCLUDED IN SCOPE OF WORK: 1. PORCHES, STEPS, AND RAMPS TO BE SUPPLIED AND INSTALLED BY OTHERS IN ACCORDANCE WITH THE LOCAL BUILDING DEPARTMENT 2. PORTABLE FIRE EXTINGUISHERS TO BE SUPPLIED AND INSTALLED ON SITE BY OWNER IN ACCORDANCE WITH LOCAL BUILDING DEPARTMENT 3. ACCESSIBLE DRINKING FOUNTAIN TO BE PROVIDED ON SITE BY OWNER LOCATED WITHIN 500 FEET ON AN ACCESSIBLE ROUTE 4. ADDITIONAL HANDICAP TOILET FACILITIES PROVIDED IN ADJACENT BUILDING ON THE SAME PROPERTY LOCATED WITHIN 500 FEET ON AN ACCESSIBLE ROUTE 5. SERVICE SINK PROVIDED IN ADJACENT BUILDING ON THE SAME PROPERTY 6. ANY REQUIRED FIRE/SMOKE DETECTION AND/OR SUPPRESSION TO BE INSTALLED BY OTHERS ON SITE IN ACCORDANCE WITH THE LOCAL BUILDING DEPARTMENT 7. THE BUILDING OWNER IS RESPONSIBLE FOR THE DEVELOPMENT & DESIGN OF ALL SITE REQUIRED ACCESSIBILITY ELEMENTS. THESE ELEMENTS ARE NOT INCLUDED IN THE SCOPE OF THIS DESIGN. SUBMITTALS ARE REQUIRED BY OWNER THROUGH THEIR DESIGN PROFESSIONAL CA: 2019 CBC, 2019 CPC, 2019 CMC, 2019 CEC, 2019 CA Energy, & 2019 CBC Chapter 11B Accessibility NO OF MODULES.3 BUILDING SQ.FT.2100 TYPE OF CONSTRUCTION. VB OCCUPANCY USE GROUP. E (Ages 5 thru 8) OCCUPANCY LOAD.75 (Classrooms) 4 (Remainder) 79 Total FLOOR LIVE LOAD.50 psf. (2000 lb concentrated) (100 psf. @ corridor) ROOF LIVE LOAD.20 psf. ROOF DEAD LOAD.10 psf. ROOF SNOW LOAD.20 psf. WIND LOAD. OCCUPANCY/RISK CATG. II SEISMIC PERMISSIBLE GAS TYPE. N/A CLIMATE ZONE.6 NAME AND DATE OF CODES; Ss=3.730, S1=1.389 Site Class 'D' Design Category 'E' MANUFACTURER & ADDRESS PHOENIX MODULAR 5301 W. MADISON ST. (SEE WEBSITE FOR PHOENIX, AZ. 85043 WARRANTY INFORMATION)PHOENIXMODULAR.COM STATE REQUIRED INFORMATION ON USE AND LOCATION OF FACTORY-BUILT BUILDING 1. PROPOSED ADDRESS 2. EXPLANATION OF AND/OR LOCATION OF UNIT. BUILDING USE. 3. SET TYPE ASSUMED F.F. TO BE 4" A.F.G. CLASSROOMS NEWPORT BEACH, CA 92633 1541 MONROVIA AVE. PAD/PIER PIT SET 2019 CBC - 115 MPH, EXP. C SITE INSTALLED FIRE ALARM RED TAG: R. MARK STEELE, P.E. CORPORATE ENGINEER SUNBELT MODULAR, INC 5301 W. MADISON ST. PHOENIX, AZ. 85043 (602) 327-47695301 W. MADISON ST. - PHOENIX, AZ 85043PH 602-447-6460 FAX 602-447-6476SUNBELT MODULAR, INC. AMTEX I INDICOM I PHOENIX I M.R. STEELTHESE DRAWINGS REMAIN THE PROPERTY OF PHOENIX MODULAR AND ARE NOT TO BE USED IN ANYWAY WITHOUT WRITTEN PERMISSION. SHEET: 6 OF DEALER: MOBILE MODULAR PROJECT: NEWPORT BEACH CLASSROOM STATES: CALIFORNIA SERIAL NUMBERS: PMI-4943-3660 DRAWN BY: RH / KT PLOT DATE: 5/13/2021 REV # / DATE: 01 04/20/2021 PR# 4 & 5 02 04/21/2021 PR# 8 03 04/27/2021 PR# 9 ---- ---- ---- ---- ---- ----PHOENIXMODULARFINAL RELEASE 5/13/2021 PRODUCTION SET 1 AXLE OFFSET 3/8" = 1'-0" PA2021-118 HVAC3 ton 5KwMODULE ( )1MODULE ( )2MODULE ( )3HC 9'-8 1/2" 7'-10" 60'-0"6'-4 1/2"CH 7'-4" CH 24'-5" 21'-1 1/4"21'-1 1/4"15'-0"35'-0"11'-8"11'-8"11'-8"0203 040404 02 02 011011011A11 47'-3" 1A1 26'-0" 1 A 1'-10" A 1 11 A 1 7'-0"53'-10" 1 1 1 1 1 A6'-6"1 1 1 1 1 1 10" 10" 1 1 1 1 1 1 1 1 1 1 1 HVAC3 ton 5KwHVAC3 ton 5KwPANEL A PANEL B PANEL C10'-11"5'-0"34'-3"22'-11 1/2"1 1 1 1 2 2 2 3 S30S70485 SF CLASSROOM CARPET 101 485 SF CLASSROOM CARPET 102 587 SF CLASSROOM CARPET 103 86 SF OFFICE CARPET 104 120 SF CORRIDOR CARPET 105 62 SF BOYS RESTROOM V.C.T. 107 47 SF GIRLS RESTROOM V.C.T. 108 47 SF UNISEX RESTROOM V.C.T. 109 7'-4" CH 30'-6" 16'-8 3/4" SPAN21'-6 3/4" SPAN21'-8 1/2" SPAN 3'-8 1/2"22'-11 1/2"7'-0" 2'-0" 17'-3 1/2" 11 38'-10 1/4"5'-5 1/2"B B B 28'-0"35'-8 1/2"46'-6" 1 1 1111 DOORS: Qty NO.Type Jamb Wall Thickness Glazing Size Rough Opening U-Factor Color Closer Deadbolt Hardware Fire Rating Keying Notes 3 3 1 3 01 02 03 04 STEEL, INSULATED 18 GA. PREFINISHED WOOD HOLLOW CORE PREFINISHED WOOD HOLLOW CORE PREFINISHED WOOD HOLLOW CORE TELL 16 GA. BRONZE TIMELY METAL JAMB BROWNTONE TIMELY METAL JAMB BROWNTONE TIMELY METAL JAMB BROWNTONE 4 7/8" 5" 4 1/2" 4 1/2" 24" X 60" FRENCH 15 LITE KIT, DUAL GLAZED NONE NONE NONE 3/0X6/8 3/0X6/8 3/0X6/8 3/0X6/8 38" x 81" 37 1/2" x 81 1/4" 37 1/2" x 81 1/4" 37 1/2" x 81 1/4" 0.31 N/A N/A N/A BEHR MIDSUMMER NIGHT (SAME BOTH SIDES) LEGACY OAK LEGACY OAK LEGACY OAK HYDRAULIC NONE NONE NONE NONE NONE NONE NONE CLASSROOM LOCK, GRADE 2 PASSAGE LEVER, TELL GRADE 2 KEYED LEVER, GRADE 2 (WITH SHIMS) PRIVACY LEVER, TELL GRADE 2 (WITH SHIMS) NONE NONE NONE NONE ALIKE N/A SEPERATE N/A DRIP CAP, (2) STD & (1) NRP HINGES, WEATHERSTRIPPING, THRESHOLD, & DOOR SWEEP. HINGES & WALL MOUNT STOPS HINGES & WALL MOUNT STOPS HINGES & WALL MOUNT STOPS WINDOWS: Qty NO.Type Glazing Size Rough Opening U-Factor SHGC Mini-Blind Notes 6 3 A B PARAMOUNT VINYL SERIES (WHITE) HORIZONTAL SLIDER WHITE VINYL HORIZONTAL SLIDER CLEAR, DUAL GLAZED, 16 LITE FRENCH GRID CLEAR, DUAL GLAZED, LOW-E 4/0X3/0 3/0X1/6 48" x 36" 36" x 18" 0.31 0.31 0.20 0.22 NONE NONE HEADER AT 81" AFF HEADER AT 81" AFF 6" 36" MIN.20" TO 25"12" TO 15"20" TO 25"12" TO 15"14" TO 17"42"1'-0" MAX HANDICAPPED WATER CLOSET FRONT VIEW (CHILD HT. / AGES: 5 - 8) HANDICAPPED WATER CLOSET SIDE VIEW (CHILD HT. / AGES: 5 - 8) 34" TO 36"18" MIN.21" TO 30"18" MIN.21" TO 30"24" TO 42"1-1/2"MINHATCHING LEGEND: 2x4 WALLS (92 5/8" STUDS) w/ R-11 UNFACED CEILING HEIGHT INSULATION. CEILING HEIGHT 1/2" TACKBOARD OVER 1/2" RAW GYPSUM. SEAMS COVERED WITH VINYL COVERED BATTS. 2x4 EXTERIOR WALLS w/ CEILING HEIGHT 1/2" TACKBOARD OVER 1/2" RAW GYPSUM. SEAMS COVERED WITH VINYL COVERED BATTS. 2x4 WALLS (FULL HEIGHT) w/ FULL HEIGHT R-11 UNFACED INSULATION. CEILING HEIGHT 1/2" TACKBOARD (CLASSROOM SIDE) OVER 1/2" RAW GYPSUM. SEAMS COVERED WITH VINYL COVERED BATTS. 1/2" RAW GYPSUM REMAINDER WAY TO RAFTERS ON BOTH SIDES OF WALL. CEILING HEIGHT1/2" VCG (RAW GYP. ABOVE) ON NON-CLASSROOM SIDE ONLY. SEE FLOOR PLAN. STRUCTURAL LEGEND Symbol Description Qty **ALL INTERIOR DIMENSIONS ARE FROM FINISH TO FINISH & ALL EXTRIOR DIMENSIONS ARE FROM STUD TO STUD** X X 1 2 3 SHEARWALL TAG (SEE STRUCTURAL PACKAGE FOR DESCRIPTION, SEE SHEET 24) HOLD DOWN TAG (SEE STRUCTURAL PACKAGE FOR DESCRIPTION, SEE SHEET 24) DIAPHRAGM CHORD TIE SIMPSON 'ST2215' (SEE DETAIL 5/2) (3) 2X4 HF #2 POST ON EACH SIDE OF MOD-LINE W/ BLOCKING UNDER POST (TYP. #3 HOLDOWN STRAP @ TOP & BOTTOM) (3) 2x4 HF #2 POST ON EACH SIDE OF MOD-LINE W/ BLOCKING UNDER POST (TYP. #3 HOLDOWN STRAP @ TOP & BOTTOM) (3) 2x4 HF #2 POST ON CLASSROOM SIDE AND (4) 2x4 HF #2 POST ON CORRIDOR SIDE OF MOD-LINE (SEE DETAIL 4/2) W/ BLOCKING UNDER POST (TYP. #3 HOLDOWN STRAP @ TOP & BOTTOM) TYP @ 4 LOCATIONS TYP @ 40 LOCATIONS TYP @ 4 LOCATIONS TYP @ 4 LOCATIONS TYP @ 3 LOCATIONS TYP @ 1 LOCATIONS PLUMBING: Symbol Type Qty Note Description CHHC S30 S70 Water Closet Urinal Grab Bars Paper Holder Lavatory Mirror Water Heater Water Heater Water Hammer In-line Strainer Supply DWV System R.R. Sign R.R. Sign R.R. Sign Partition(s) 3 1 3 3 3 3 1 1 2 1 1 1 1 1 1 1 AS2599001.20 Low Flow AS6047.121.002 Flush Valve w/ Ferguson F-182 Outside Stem AS500g.055.020 Seat Low Flow Low Flow Mixing Valves Chronomite: S30LLMB120V or equal Chronomite: S70WMD240V or equal 1" 2" Copper Inlet Door Mtd Door Mtd Door Mtd Color to be: (532 LATTE) Floor mtd. ADA elongated child height with flush valve and shut off valve / flush handle to be on open side of r.r. (Factory standard) See Fixture Details 2/2 for mounting heights. Wall hung white vitreous with commercial grade flush valve w/ rim at 15" a.f.f. (Factory standard) Set(s) with (1) each 42", 36" horizontal, and 18" vertical Single roll wall mount toilet paper holder mtd. ADA height (Factory standard) 19" X 17" White vitreous wall hung with ADA handles and shut off valves mounted at child height. (Factory standard) See Fixture Details 3/2 for mounting heights. 24"x36" w/ clips mtd. 38" to bottom edge (Factory standard) Insta-Hot Chronomite S-30 (Electric - 120V) Insta-Hot Chronomite S-70 (Electric - 240V) Water hammer arrestor Strainer at supply entrance Type M copper or Pex ABS Schedule 40 (Manifold is by others) Unisex ADA restroom sign w/ braille mtd. 59" a.f.f. to center Women's ADA restroom sign w/ braille mtd. 59" a.f.f. to center Men's ADA restroom sign w/ braille mtd. 59" a.f.f. to center 18" Prefinished metal urinal partition(s). TOP TRIM (SHIP LOOSE & SITE INSTALLED OVER TENSION TIE) TENSION TIE (SHIP LOOSE & SITE INSTALL) 4" L.P. TRIM (SHIP LOOSE & SITE INSTALLED) J-RAIL (FACTORY INSTALLED)MODULELINE6" L.P. TRIM (FACTORY INSTALLED) 1'-6"1'-6" J-RAIL (SHIP LOOSE & SITE INSTALLED OVER TRIM) WALL FINISH VALUE (LBS)STRAP TYPE FASTENERS SIMPSON 'ST2215'(20) 10d NAILS (0.148"Ø x 1-1/2")1580# LAV CLEARANCES (ALL RESTROOMS)34" TO 37"17" MIN FIXTURE DEPTH 6" MAX TOE CLEARANCE9" MIN26" MIN31" MAX24" MIN8" KNEE CLEARANCE CLEAR FLOOR SPACE AT LAVATORIES (ALL RESTROOMS)30" MIN.17" MIN. 19" MAX.48" MAX. 5" CLEAR FLOOR SPACE HANDI GUARD ON ALL EXPOSED PIPESMIRROR MOD LINE 2x STUD EA. SIDE 3-STUD COLUMN WALL FINISH (TYP) WALL FINISH (TYP) 2-STUD COLUMN 1 FLOOR PLAN 1/4"=1'-0" SQUARE FOOTAGE - 2100 S.F. OCCUPANCY LOAD = 100 2 5 ROOF DIAPHRAGM MODLINE CHORD TIE 3/4" = 1'-0" R. MARK STEELE, P.E. CORPORATE ENGINEER SUNBELT MODULAR, INC 5301 W. MADISON ST. PHOENIX, AZ. 85043 (602) 327-47695301 W. MADISON ST. - PHOENIX, AZ 85043PH 602-447-6460 FAX 602-447-6476SUNBELT MODULAR, INC. AMTEX I INDICOM I PHOENIX I M.R. STEELTHESE DRAWINGS REMAIN THE PROPERTY OF PHOENIX MODULAR AND ARE NOT TO BE USED IN ANYWAY WITHOUT WRITTEN PERMISSION. SHEET: 6 OF DEALER: MOBILE MODULAR PROJECT: NEWPORT BEACH CLASSROOM STATES: CALIFORNIA SERIAL NUMBERS: PMI-4943-3660 DRAWN BY: RH / KT PLOT DATE: 5/13/2021 REV # / DATE: 01 04/20/2021 PR# 4 & 5 02 04/21/2021 PR# 8 03 04/27/2021 PR# 9 ---- ---- ---- ---- ---- ----PHOENIXMODULARFINAL RELEASE 5/13/2021 PRODUCTION SET 4 COLUMN DETAIL 1" = 1'-0" 2 FIXTURE DETAILS 1/4" = 1'-0" 3 FIXTURE DETAILS 1/4" = 1'-0"1 1 2 3 3 PA2021-118 GFCI WR 3B HVAC2,4C 3 ton 5KwPC 1C MODULE ( )1EXIT 1C 5A 5A 5A MODULE ( )2MODULE ( )3HC CH CH T T T EXIT 1C EXIT 1B SHIPPED LOOSE PC 1B SHIPPED LOOSE PC 1C SHIPPED LOOSE HVAC2,4B 3 ton 5KwHVAC2,4A 3 ton 5KwPANEL A PANEL B PANEL C GFCI WR 3AS307AS706,8ACH 1A 3DIM 3DIM 3DIM 3 3 3 O O O O 1B GFCI +42"5A TR GFCI +42"5A TR GFCI +42"3A TR FA +46 6C P+46 H+82 P+46 H+82 P+46 H+82 XH +102 3A TR 5A TR 3A TR 3B TR 5C TR 3C TR 3B TR 3C TR 3B TR 3A TR 5C TR 3C TR 3C TR 5C TR 3B TR 3B TR 5C TR 3B TR 3C TR 5A TR H +82 DIM 6 3A TR ELECTRICAL: Symbol Type Qty Note Description 4K 6K PC EXIT EXIT EXIT 3 O DIM 3DIM OCC GFCI WR TR TR GFCI 6 FA P H XH RE A/V SDD T Elec Service Elec Raceway Elec Panel Lights Lights Lights Lights Emerg. Light Emerg. Light Exit Sign Exit Sign Emerg. Light Switch Switch Switch Switch Occupancy Sensor Receptacle Receptacle Receptacle Receptacle J-Box J-Box J-Box J-Box J-Box J-Box Water Heater J-Box Water Heater J-Box J-Box Audio / Visual Indicator Exhaust Fan T-Stat Device Color 1 1 3 3 10 3 3 3 3 1 1 2 3 4 1 3 4 3 2 21 3 9 1 1 3 4 1 1 1 3 3 3 3 1 12-Space Leviton LP212-3B 4000 Lumen 6000 Lumen Westgate: LSW-30CW-PC or equal Topaz: F-FM11/15/RN/ P/30/WH or equal Red lens Red lens Red lens Wattstopper: IOS-DOV or equal Lutron: DVTV or equal Lutron: DVSTV or equal Sensor: CI-205 / Power pack: BZ-150 or equal 3/4" Conduit stubbed above ceiling Future inlet Relay: #90370 Air Products (MS Series): MS-RA/P/A or equal Broan: 671 or equal White Rogers: 1F951277 120/240V 60 HZ. single phase MC Cable/flex 120/240v 1 PH 125 amp panel w/ 125 amp main breaker. Exterior NEMA 3R mounted 60" a.f.f. to top (Factory standard) 2'x4' Diffused LED recessed lay-in with dimmable electronic ballast (Factory standard) 2'x4' Diffused LED recessed lay-in with dimmable electronic ballast (Factory standard) 30W LED porch light with photocell mtd. 82" a.f.f. (Shipped loose) 15W Surface mounted 1100 lumen LED light Combo dual emergency light/exit sign with battery backup mtd. 88" a.f.f. (Factory standard) Exterior remote head mtd. 90" a.f.f. (Mounted in octagon box) Shipped loose Ceiling mount, 120v with battery backup Wall mount (88" a.f.f.), 120v with battery backup Interior double head battery pack mtd. 88" a.f.f. (Factory standard) 15a/120v 3-Way wall mtd. single toggle w/ cover plate (Factory standard) 20a/120v Wall mtd. occupancy / vacancy sensor w/ cover plate mtd. 46" a.f.f. 0-10v Wall mtd. dimming w/ cover plate mtd. 46" a.f.f. 0-10v Wall mtd. 3-way dimming w/ cover plate Ceiling mounted occupancy sensor w/ power pack 20a/120v Duplex w/ cover plate mtd. 18" a.f.f. (Factory standard) 20a/120v GFCI 'WR' rated exterior receptacle with weatherproof in-use cover mtd. 18" a.f.f. (Factory standard) 20a/120v Tamper resistant duplex w/ cover plate mtd. 18" a.f.f. (Factory standard) 20a/120v GFCI Tamper resistant duplex w/ cover plate mtd. 42" a.f.f. (Factory standard) 4x4 Empty box w/ sngl. gang mud ring, and blank cover plate mtd. 18" a.f.f. for future phone/date (Factory standard) 6x6x6 Empty semi-recessed NEMA-3R box w/ metal cover and 3/4" conduit stubbed above ceiling (Factory standard) 20a/120v 4x4 Wired j-box w/ sng gang mud ring, and cover plate mtd. 46" a.f.f. for future fire alarm control panel provided by fire alarm installer (Factory standard) 4X4 Empty J-box w/ sng gang mud ring, cover plate and 3/4" conduit stubbed above ceiling mtd. 46" a.f.f. for pull station by alarm provider (Factory standard) 4X4 Empty J-box w/ extension ring, cover plate and 3/4" conduit stubbed above ceiling mtd. 82" a.f.f. for horn / strobe by alarm provider (Factory standard) 4X4 Empty exterior j-box w/ sng gang mud ring, cover plate and 3/4" conduit stubbed thru wall mtd. 102" a.f.f. for horn by alarm provider (Factory standard) 120v/30a 4x4 Wired box w/ sng gang mud ring and cover plate for water heater mtd. 18" a.f.f. (Factory standard) 240v/35a 4x4 Wired box w/ sng gang mud ring and cover plate for water heater mtd. 18" a.f.f. (Factory standard) Relay mountd in 4x4 j-box w/ cover plate mtd. to rafter / install low voltage wire to HVAC terminal block (See Details 3/5 & 4/5). 4x4 J-box w/ sng gang mud ring, and face flush w/ ceiling for Audio/Visual indicator w/ 24 AWG wire in flex conduit connected to smoke duct detector @ HVAC unit (See Details 3/5 & 4/5). 70 CFM Ceiling mounted / vent thru wall Programmable T-Stat(s) mtd. 46" a.f.f. Color to be: (IVORY) / Exterior device(s) and mansonry boxes with metal cover plate as applicable NOTE: 1. ALL A.F.F. DIMENSIONS ARE TO THE CENTER OF THE DEVICE BOX UNLESS NOTED OTHERWISE (REFER TO SCHEDULE AND PLANS FOR HEIGHTS). 2. ALL ELECTRICAL ITEMS ARE FACTORY STANDARD UNLESS NOTED OTHERWISE. 3. BLANK COVERS WILL BE PROVIDED ON J-BOXES UNLESS NOTED OTHERWISE. 4. ALL EXTERIOR ELECTRICAL DEVICES TO BE WEATHERPROOF. 1 ELECTRICAL PLAN 1/4"=1'-0" 3 R. MARK STEELE, P.E. CORPORATE ENGINEER SUNBELT MODULAR, INC 5301 W. MADISON ST. PHOENIX, AZ. 85043 (602) 327-47695301 W. MADISON ST. - PHOENIX, AZ 85043PH 602-447-6460 FAX 602-447-6476SUNBELT MODULAR, INC. AMTEX I INDICOM I PHOENIX I M.R. STEELTHESE DRAWINGS REMAIN THE PROPERTY OF PHOENIX MODULAR AND ARE NOT TO BE USED IN ANYWAY WITHOUT WRITTEN PERMISSION. SHEET: 6 OF DEALER: MOBILE MODULAR PROJECT: NEWPORT BEACH CLASSROOM STATES: CALIFORNIA SERIAL NUMBERS: PMI-4943-3660 DRAWN BY: RH / KT PLOT DATE: 5/13/2021 REV # / DATE: 01 04/20/2021 PR# 4 & 5 02 04/21/2021 PR# 8 03 04/27/2021 PR# 9 ---- ---- ---- ---- ---- ----PHOENIXMODULARFINAL RELEASE 5/13/2021 PRODUCTION SET 1 PA2021-118 HVAC3 ton 5KwPC 6" 8" 10" 8" 10" 12"MODULE ( )1EXIT MODULE ( )2MODULE ( )31'-2"8"1'-1"1'-2"8"1'-4"6"1'-2"8"6" 6" 3'-0 1/2" 3'-0 1/2" 1'-5 3/4" 1'-8"11"1'-8"1'-11 1/2"2'-3" 4K 1A 6K 1B 6K 1B 6K 1B 6K 1B 6K 1C 6K 1C 6K 1C 6K 1C 6K 1C 6K 1C 1A 1A 1A 4K 1A 4K 1A8" 6"6" T 10"10" T 10"10" T 10" 10" 10" 10" 10" 10" 10" EXIT EXIT PCPC HVAC3 ton 5KwHVAC3 ton 5KwPANEL A PANEL B PANEL C10"10"10"70 CFM 1A 70 CFM 1A 70 CFM 1A 3DIM 3DIM 3DIM 3 3 3 O O O O OCC OCC OCCEXIT1AEXIT1A OCC DIM RE RE RE A/V SDD A/V SDD A/V SDD 8" INDICATES T-GRID SUSPENDED CEILING INSTALLED @ FACTORY INDICATES SUSPENDED CEILING HOLD-BACK @ MATELINES, TO BE COMPLETED ON-SITE BY OTHERS CEILING LEGEND PLUMBING VENT PREMOLDED EPDM PIPE BOOT CLAMPING RING LAP SEALANT 6" MINLAP SEALANT BUTYL TAPE TAPE PRIMER ROOF UNDERLAYMENT EPDM MEMBRANEROOF SHEATHING LP TRIM END JOIST OR DBL RIM JOIST FLOOR DECKING WALL STUDS @ 16" O.C. LP SIDING 3/4" BOTTOM PLATE P.T. FILLER SAN-T2"2"URINAL C.O. V.T.R 3" LTTY WASTE & VENT LEGEND DESCRIPTIONSYM WASTE DRAIN (FACTORY INSTALLED) WASTE DRAIN (SUPPLIED & INSTALLED BY OTHERS) WASTE VENT (FACTORY INSTALLED) NOTE: 1. ALL PIPE TO BE ABS SCHEDULE 40 & WILL SLOPE 1/4 PER FOOT. 2. PLUMBING MANIFOLD TO BE SUPPLIED & INSTALLED AT SITE BY OTHERS. SAN-T2"3"W.C. SAN-T2"2"LAV. LTTY SAN-T2"3"W.C. LTTY SAN-T2"2"LAV. LTTY LTTY LTTY SAN-T2"3"W.C. SAN-T2"2"LAV. LTTY HAMMERLAV.1/2"1/2"1"W.C. 2" INLET G.V. INLINE STRAINER COLD & HOT SCHEMATIC 1. MAX PRESSURE RANGE @ CONNECTION: 2. MAX DEVELOPED LENGTH: NOTE: A. PEX HOT / COLD WATER SUPPLY MAY BE INSTALLED ABOVE CEILING. 30-45 (UPC) 100'1"W.C. LAV.1/2"1/2"3/4"URINAL 1"W.C. LAV.1/2"1/2"HAMMER1 REFLECTED CEILING PLAN 1/4"=1'-0" 4 R. MARK STEELE, P.E. CORPORATE ENGINEER SUNBELT MODULAR, INC 5301 W. MADISON ST. PHOENIX, AZ. 85043 (602) 327-47695301 W. MADISON ST. - PHOENIX, AZ 85043PH 602-447-6460 FAX 602-447-6476SUNBELT MODULAR, INC. AMTEX I INDICOM I PHOENIX I M.R. STEELTHESE DRAWINGS REMAIN THE PROPERTY OF PHOENIX MODULAR AND ARE NOT TO BE USED IN ANYWAY WITHOUT WRITTEN PERMISSION. SHEET: 6 OF DEALER: MOBILE MODULAR PROJECT: NEWPORT BEACH CLASSROOM STATES: CALIFORNIA SERIAL NUMBERS: PMI-4943-3660 DRAWN BY: RH / KT PLOT DATE: 5/13/2021 REV # / DATE: 01 04/20/2021 PR# 4 & 5 02 04/21/2021 PR# 8 03 04/27/2021 PR# 9 ---- ---- ---- ---- ---- ----PHOENIXMODULARFINAL RELEASE 5/13/2021 PRODUCTION SET 2 PLUMBING VENT 1 1/2"=1'-0" FACTORY INSTALLED 3 WALL FINISH 1 1/2"=1'-0" AT FLOOR 1 PA2021-118 HVAC3 ton 5Kw6" 8" 10" 8" 10" 12"MODULE ( )1MODULE ( )2MODULE ( )3TS-3TS-3TS-322x10 22x10 1'-8"16x1016x1016x10 22x1022x1022x1022x1022x10 8" 6"6" T 22x1022x1022x1022x10 22x1022x1022x1022x10 22x10 22x10 10"10" T 10"10" T 10" 10" 10" 10" 10" 10" 10" 22x1016x1016x1016x10 22x1016x1016x1016x10 5'-8"9'-8"5'-6"9'-6"2'-4"6'-8"HVAC3 ton 5KwHVAC3 ton 5KwPANEL A PANEL B PANEL C 70 CFM 70 CFM 70 CFM 29'-0"37'-0"49'-0" 22x10 8" 16x101'-0"HVAC: Symbol Type Qty Note Description HVAC Heat Pump HVAC Unit Duct Sleeve Return Air Plenum Fiberglass Duct Fiberglass Duct Fiberglass Duct Fiberglass Duct Fiberglass Duct Fiberglass Duct Supply Diffusers Supply Diffusers Supply Diffusers R/A Grille R/A Grille R/A Grille Duct type 3 3 3 8 2 1 16 1 2 3 2 7 2 6 1 1 CRV - Smoke Duct Detector - FIRE ALARM RELAY 6" 8" 10" 8" 10" 12" 3 Ton heat pump with 5KW heat strip 11 EER end mount unit / Model: W36HB-A05 or equal (See Details 3/5 and 4/5 for J-box locations and wiring diagram) 29"x9" To 22"x10" Galvanized sleeve, 16" long 32"x7" Return air plenum w/ 28"x14"x4" tap-in 16"x10"x10'-0" Fiberglass 16"x10"x7'-6" Fiberglass 22"x10"x2'-6" Fiberglass 22"x10"x10'-0" Fiberglass 22"x10"x7'-6" Fiberglass 22"x10"x5'-0" Fiberglass 24" x 24" 4-way throw diffuser with start collar, collar w/ scoop and damper, and flex (Factory standard) 24" x 24" 4-way throw diffuser with start collar, collar w/ scoop and damper, and flex (Factory standard) 24" x 24" 4-way throw diffuser with start collar, collar w/ scoop and damper, and flex (Factory standard) 24" x 24" Perforated lay-in with start collar, collar, and flex (Factory standard) 24" x 24" Perforated lay-in with start collar, collar, and flex (Factory standard) 24" x 24" Perforated lay-in with start collar, collar, and flex (Factory standard) R-4.2 Fiberglass insulation. Flex duct not to exceed 5' CEILING MTD. INDICATOR LOW VOLTAGE WIRE FROM ADDED CONTACTS J-BOX FOR FUTURE FIRE ALARM LOW VOLTAGE WIRE FROM SMOKE DETECTOR TO INDICATOR C B/W1 G W2 RT W3 R 1 Y1 2 Y2 3 A 4 D 5 L 6 BLACK / RED TO CEILING BOX BLUE / WHITE TO CEILING BOX WIRE TO T-STAT T R O U B L E A L A R M ADDED CONTACTS FOR SMOKE DETECTION ALARM ALL WIRE TO BE #18 AWG (LOW VOLTAGE) COM OPEN COM OPEN CONNECT TO REMAINING BLACK WIRE FROM T/R BUTTON CONNECT TO BLACK WIRE FROM PILOT LED & BLACK WIRE FROM T/R BUTTON CONNECT TO BLACK WIRES FROM GREEN & RED LED CONNECT TO RED WIRE FROM ALARM LED T-STAT WIRE COMING FROM THE SMOKE DETECTOR WIRING FOR INDOOR CEILING INDICATOR 1 HVAC PLAN 1/4"=1'-0" 5 R. MARK STEELE, P.E. CORPORATE ENGINEER SUNBELT MODULAR, INC 5301 W. MADISON ST. PHOENIX, AZ. 85043 (602) 327-47695301 W. MADISON ST. - PHOENIX, AZ 85043PH 602-447-6460 FAX 602-447-6476SUNBELT MODULAR, INC. AMTEX I INDICOM I PHOENIX I M.R. STEELTHESE DRAWINGS REMAIN THE PROPERTY OF PHOENIX MODULAR AND ARE NOT TO BE USED IN ANYWAY WITHOUT WRITTEN PERMISSION. SHEET: 6 OF DEALER: MOBILE MODULAR PROJECT: NEWPORT BEACH CLASSROOM STATES: CALIFORNIA SERIAL NUMBERS: PMI-4943-3660 DRAWN BY: RH / KT PLOT DATE: 5/13/2021 REV # / DATE: 01 04/20/2021 PR# 4 & 5 02 04/21/2021 PR# 8 03 04/27/2021 PR# 9 ---- ---- ---- ---- ---- ----PHOENIXMODULARFINAL RELEASE 5/13/2021 PRODUCTION SET 3 ADDED WIRE TO BOXES 3/4"=1'-0"4 WIRING DIAGRAM N.T.S. 1 1 PA2021-118 A B D C 14'-3 7/16" SHIPPING HEIGHT HATCHING DENOTES SHIPLOOSE TRIM 6x6 INLET BOX (TYP. 1) PORCH LIGHT (TYP 3) (3) SHIPPED LOOSE REMOTE HEAD (TYP 3) (3) SHIPPED LOOSE EXHAUST FAN VENT (TYP 3) 4" SMART TRIM (DOOR) 4" SMART TRIM (WINDOW) 2 5 ELEC. PANEL (TYP. 3)WP GFCI RECEP (TYP. 2) HOOD 6" SMART TRIM (TOP HORIZONTAL) BODY 4" SMART TRIM (INTERMEDIATE HORIZONTAL) 4" SMART TRIM (CORNER) 8" SMART TRIM (BOTTOM HORIZONTAL) 4" SMART TRIM (MOD-LINE) 4" SMART TRIM (MOD-LINE) ELEVATION ' ' ELEVATION ' ' ELEVATION ' 'ELEVATION ' ' 12"1/4"12"1/4" 12"1/4"12"1/4"7'-10" CEILING HEIGHT3'-0" MAX 60'-0" FLOOR LENGTH 27 1/2"PEAKPLYWOOD BEAM GRADE2'-10"109" MIN. STUD HT.116 5/16" MAX STUD HT.2 4 3 46 3/4"14'-3 7/16" SHIPPING HEIGHT W/ PLUMBING VENT3/4" T&G PLYWOOD DECKING 2X8 FLOOR JOISTS @ 16" O.C. 3/8" LP SMART PANEL SIDING OVER BARRICADE WRAP 1/2" VINYL TACK BOARD OVER 1/2" RAW GYP. ON 2x4 INT. STUDS @ 16" O.C. SUSPENDED LAY-IN CEILING @ 7'-10" A.F.F. R-19 UNFACED INSULATION 2X8 RAFTERS12"1/4" R-19 UNFACED BATT EPDM ROOFING R-13 KRAFT FACED INSULATION20" HEEL1/2" VINYL TACK BOARD OVER 1/2" RAW GYP. ON 2x4 EXT. STUDS @ 16" O.C.20" HEEL12"1/4" 1 BUILDING CROSS-SECTION 1/4"=1'-0" 6 R. MARK STEELE, P.E. CORPORATE ENGINEER SUNBELT MODULAR, INC 5301 W. MADISON ST. PHOENIX, AZ. 85043 (602) 327-47695301 W. MADISON ST. - PHOENIX, AZ 85043PH 602-447-6460 FAX 602-447-6476SUNBELT MODULAR, INC. AMTEX I INDICOM I PHOENIX I M.R. STEELTHESE DRAWINGS REMAIN THE PROPERTY OF PHOENIX MODULAR AND ARE NOT TO BE USED IN ANYWAY WITHOUT WRITTEN PERMISSION. SHEET: 6 OF DEALER: MOBILE MODULAR PROJECT: NEWPORT BEACH CLASSROOM STATES: CALIFORNIA SERIAL NUMBERS: PMI-4943-3660 DRAWN BY: RH / KT PLOT DATE: 5/13/2021 REV # / DATE: 01 04/20/2021 PR# 4 & 5 02 04/21/2021 PR# 8 03 04/27/2021 PR# 9 ---- ---- ---- ---- ---- ----PHOENIXMODULARFINAL RELEASE 5/13/2021 PRODUCTION SET 2 1 1 3 PA2021-118 HVAC3 ton 5KwMODULE ( )1MODULE ( )2MODULE ( )3HVAC3 ton 5KwHVAC3 ton 5Kw1'-1 1/2"7'-0"26'-0"51'-6"53'-10"60'-0"11'-8"6'-6"11'-8"11'-8"11'-4 1/2"6'-11"25'-2 1/2"7'-5"15'-1 1/2"6'-5 1/2"11'-0"7'-8 1/2"15'-5"25'-6" 21'-7"34'-11"43'-1 1/2"11'-8"11'-4 1/2"1'-1 1/2" 1'-10"7'-0" 16'-7" 26'-0"17'-3 1/2" 38'-1 3/4" 47'-3"60'-0" 2X6 PLUMBING WALL 16'-7" 38'-10 1/4"5'-7 1/2"5'-1"5'-4 1/2"4'-0 1/2" 28'-0"35'-8 1/2"46'-6"6'-8"6'-2"5'-8"1'-8 1/2" 9'-5"20'-2 1/2"0'1'-4"2'-8"4'5'-4"6'-8"8'9'-4"10'-8"12'13'-4"14'-8"16'17'-4"18'-8"20'21'-4"22'-8"24'25'-4"26'-8"28'29'-4"109109 5/16109 5/8110110 5/16110 5/8111111 5/16111 5/8112112 5/16112 5/8113113 5/16113 5/8114114 5/16114 5/8115115 5/16115 5/8116116 5/161 WALL SET 1/4"=1'-0" WS 2 BALLOON WALL 1/4"=1'-0" R. MARK STEELE, P.E. CORPORATE ENGINEER SUNBELT MODULAR, INC 5301 W. MADISON ST. PHOENIX, AZ. 85043 (602) 327-47695301 W. MADISON ST. - PHOENIX, AZ 85043PH 602-447-6460 FAX 602-447-6476SUNBELT MODULAR, INC. AMTEX I INDICOM I PHOENIX I M.R. STEELTHESE DRAWINGS REMAIN THE PROPERTY OF PHOENIX MODULAR AND ARE NOT TO BE USED IN ANYWAY WITHOUT WRITTEN PERMISSION. SHEET: 6 OF DEALER: MOBILE MODULAR PROJECT: NEWPORT BEACH CLASSROOM STATES: CALIFORNIA SERIAL NUMBERS: PMI-4943-3660 DRAWN BY: RH / KT PLOT DATE: 5/13/2021 REV # / DATE: 01 04/20/2021 PR# 4 & 5 02 04/21/2021 PR# 8 03 04/27/2021 PR# 9 ---- ---- ---- ---- ---- ----PHOENIXMODULARFINAL RELEASE 5/13/2021 PRODUCTION SET PA2021-118 PA2021-118 PA2021-118 PA2021-118 PA2021-118 PA2021-118 PA2021-118