Loading...
HomeMy WebLinkAbout20210527_Plans_11x17.,; . • 0 ~z u-• C ~! 'O • . -. "' '"' • 0 .o- •L C o, 2 "C C m OL u- ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUCTED TO PERMIT WORK NOT CONFORMING TO THESE CODES. 1. 2019 CALIFORNIA ADMINISTRATIVE CODE 2. 2019 CALIFORNIA BUILDING CODE 3. 2019 CALIFORNIA ELECTRICAL CODE 3a. 2017 NATIONAL ELECTRICAL CODE (NEC) 4. 2019 CALIFORNIA MECHANICAL CODE 5. 2019 CALIFORNIA PLUMBING CODE 6. 2019 CALIFORNIA FIRE CODE 7. ANY LOCAL BUILDING CODE AMENDMENTS TO THE ABOVECITY /COUNTY ORDINANCES 8. CALIFORNIA VEHICLE CODE/WATCHBOOK TRAFFIC CONTROL HANDBOOK. HANDICAP REQUIREMENTS: FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. HANDICAPPED ACCESS NOT REQUIRED IN ACCORDANCE WITH CALIFORNIA ADMINISTRATIVE STATE CODE PART 2, TITLE 24, CHAPTER 11 B, SECTION 1103B. CODE COMPLIANCE THE FACILITY IS UNMANNED ANO NOT FOR HUMAN HABITATION. A TECHNICIAN WILL VISIT THE SITE AS REQUIRED FOR ROUTINE MAINTENANCE. THE PROJECT WILL NOT RESULT IN ANY SIGNIFICANT DISTURBANCE OR EFFECT ON DRAINAGE; NO SANITARY SEWER SERVICE, POTABLE WATER, OR TRASH DISPOSAL IS REQUIRED AND NO COMMERCIAL SIGNAGE IS NEW . GENERAL NOTES PROPERTY OWNER: ADDRESS: APPLICANT: ADDRESS: LA TITIJDE (NAO 83): LONGITIJOE (NAO 83): LONGITIJDE/LA TITIJDE TYPE: GROUND ELEVATION (NAVO 88): ADJACENT APN #: ZONING JURISDICTION: CURRENT ZONING: PROPOSED USE: DIG ALERT Ut«RGROI.Nl SEFMCE Al..£RT or SOUTHERN CU"ORNA DIAL TOLL FREE 1-800-277-2600 AT LEAST TWO DAYS BEFORE YOU DIG PUBLIC RIGHT OF WAY 1991 PORT EDWARD CIR NEWPORT BEACH, CA 92660 AT&T 1452 EDINGER A VE, 3rd FLOOR, TIJSTIN, CA 92780 33' 36' 57.91" N 33.616086' 117' 51' 27.85" W -117.857736' NAO 83 258.45' A.M.S.L 458-284-04 CITY OF NEWPORT BEACH PUBLIC RIGHT OF WAY UNMANNED TELECOMMUNICATIONS FACILITY SITE INFORMATION PROJECT MANAGER: AT&T Mobility 1452 Edinger Ave. Tustin, CA 92780 CONTACT: Stacey Brown 714-273-5261 sb6766@ott.com SAC/ZONING/PERMITTING: Bechtel Infrastructure & Power Corp. 16808 Armstrong Ave. Irvine, CA 92606 CONTACT: John Tseheridis 946-372-4519 jtseheri@bechtel.com RF ENGINEER: AT&T Mobility 1452 Edinger Ave. Tustin, CA 92780 CONTACT: Mohesh Kolur 714-566-7311 mk5852@ott.com ENGINEER: Bechtel Infrastructure & Power Corp. 16808 Armstrong Ave. Irvine, CA 92606 CONTACT: George Moroles 949-372-4476 gmoroles@bechtel.com CONSTRUCTION GC: Bechtel Infrastructure & Power Corp. 16808 Armstrong Ave. Irvine, CA 92606 CONTACT: Jon Awerkomp 949-372-4445 jowerkom@bechtel.com SENIOR TECHNICAL PROJECT MANAGER: AT&T Mobility 1452 Edinger Ave. Tustin, CA 92780 CONTACT: Don Vozenilek 562-716-4647 dv5 7 4p@ott.com PROJECT TEAM 6 SITE NAME: NWPTB NODE 015A SITE NUMBER: CRAN RLOS NWPTB 015 - - - PROJECT: CRAN/ SMALL CELL/ MICRO USID #:230808 PACE#: MRLOS056311 at&t POLE TYPE: (N) STEEL POLE POLE ID #: 3454 SITE ADDRESS: 1991 PORT EDWARD CIR NEWPORT BEACH, CA 92660 VICINITY MAP LOCAL MAP DRIVING DIRECTIONS FROM AT&T TUSTIN OFFICE: GET ON STATE RTE 55 S IN SANTA ANA FROM EDINGER AVE, CONTINUE ON STATE RTE 55 S. TAKE CA-73 S TO BONITA CANYON DR IN NEWPORT BEACH. TAKE EXIT 12 FROM CA-73 S, CONTINUE ON BONITA CANYON DR. TURN LEFT ONTO SAN MIGUEL DR, TURN RIGHT ONTO PORT DUTTON DR, TURN RIGHT ONTO NEWPORT HILLS DR E, THE SITE WILL ON THE RIGHT. DRIVING DIRECTIONS 5 4 3 IF USING 11"X17" PLOT, DRAWINGS WILL BE HALF SCALE CONSTRUCTION DRAWING THE FOLLOWING PARTIES HEREBY APPROVE AND ACCEPT THESE DOCUMENTS & AUTHORIZE THE SUBCONTRACTOR TO PROCEED WITH THE CONSTRUCTION DESCRIBED HEREIN. ALL DOCUMENTS ARE SUBJECT TO REVIEW BY THE LOCAL BUILDING DEPARTMENT & MAY IMPOSE CHANGES OR MODIFICATIONS. APPROVED BY: INITIALS: DATE: AT&T RF ENGINEER: -----------------+----+------t AT&T OPERATIONS: -----------------t-----+------t SITE ACQUISITION MANAGER: __________________ ,__ ___ ___,, PROJECT MANAGER: ________________ +-----+------ ZONING VENDOR-· -----------------+---+------1 LEASING VENDOR: -----------------+----+------1 CONSTRUCTION MANAGER: --------------+----+-----I A/E MANAGER: _________________ -+---+------I PROPERTY OWNER:----------------~---~-------1 APPROVALS SCOPE OF WORK: AT&T PROPOSES TO MODIFY, OPERATE AND MAINTAIN PROPOSED UNMANNED TELECOM FACILITY. THE SCOPE WILL CONSIST OF THE FOLLOWING: 1. AT&T TO REMOVE (E) CONCRETE STREET LIGHT POLE AND INSTALL (N) STEEL STREET LIGHT POLE ON (N) POLE FOUNDATION AT SAME LOCATION. 2. INSTALL (1) (N) OMNI ANTENNA AND (1) (N) SHROUD ON TOP OF (N) STREET LIGHT POLE 3. (1) (N) RRUS-4449 85/812 WITH (2) (N) PSU AC 08 UNITS, (1) (N) RRUS-4415 825 WITH (1) (N) PSU AC 08 UNIT & (1) (N) SPD UNIT WITHIN ( 1) (N) POLE BASE PEDESTAL. 4. INSTALL (1) (N) 17"x30" FIBER PULL BOX BY AT&T WIRELINE 5. INSTALL (1) (N) 17"x30" SCE PULL BOX BY AT&T MOBILITY. 6. INSTALL (1) (N) 17"x30" AT&T POWER PULL BOX WITH WTR/FSB BY AT&T MOBILITY. 7. GC TO TRENCH & INSTALL CONDUITS FOR POWER/FIBER AS REQUIRED. PROJECT DESCRIPTION SHEET DESCRIPTION T-1 TITLE SHEET T-2 LEGEND, ABBREVIATIONS AND GENERAL LS-1 TOPOGRAPHIC SURVEY (BY OTHERS) A-1 SITE PLAN AND CITY OF NEWPORT BEACH NOTES A-2 ENLARGED SITE PLAN A-3 ELEVATIONS A-4 SITE IMAGE & ELEVATION A-5 EQUIPMENT DETAILS A-6 EQUIPMENT DETAILS A-7 CITY STANDARD DETAILS E-1 ELECTRICAL AND GROUNDING DETAILS E-2 LUMINAIRE SPECIFICATIONS (FOR REFERENCE) UD-1 CONCEALFAB POLE # 900794_6 DETAILS (BY OTHERS) UD-2 FOUNDATION DETAILS TCP-1 TRAFFIC CONTROL PLAN SHEET INDEX SUBCONTRACTOR SHALL VERIFY ALL PLANS & EXISTING DIMENSIONS & CONDITIONS ON THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. DO NOT SCALE DRAWINGS 2 APPLICANT: at&t Mobility 1452 EDINGER AVENUE, 3rd FLOOR TUSTIN, CA 92780 ENGINEER: BECHTEL INFRASTRUCTURE AND POWER CORPORATION 16808 ARMSTRONG AVENUE, SUITE 225, IRVINE, CA 92606 (°RAWN BY: CHECKED BY: 1 0 A REV REVISIONS: 05/26/21 REVISEO PER CITY COMMENTS 07/15/20 ISSUED EOR PERMIT/ CONSTRUCTION 06/05/20 ISSUED FOR REVIEW DATE DESCRIPTION LICENSER: PROJECT INFORMATION: NWPTB NODE 01 SA 1991 PORT EDWARD CIR NEWPORT BEACH, CA 92660 BECHTEL DRAWING NUMBER 26134-617-C0-0000-01032-001 SHEET TITLE: TlllE SHEET SHEET NUMBER: T-1 SB SAS SRR BY D C B A PA2021-123 LEGEND Q NEW ANTENNA EXISTING ANTENNA GROUND ROD ,--, • ■ GROUND BUS BAR MECHANICAL GRNO. CONN . CADWELD GROUND ACCESS WELL (I] ELECTRIC BOX CD TELEPHONE BOX LIGHT POLE FNO. MONUMENT SPOT ELEVATION SET POINT REVISION GRID REFERENCE OET AIL REFERENCE ELEVATION REFERENCE ~ SECTION REFERENCE ABBREVIATIONS A A.B. ABV. AMPERE ANCHOR BOLT ABOVE ( I CD ---A---. --ou--- ---x--- --OHT/OHP-- ---OHT--- ---OHP--- --E-- --F/P-- EMT. E.N. ENCL. ENG. AC ACCA AOD'L A.F.F. A.F.G. A.G.L. AIC ALUM. ALT. ANT. APPROX. ARCH. AT. ALTERNATE CURRENT /AIR CONDITIONER AlfTEN~ CABLE COVER AS~EMBLY EQ. EXST.(E) EXP. EXT. AWG. BATT. BO. BLOG. BLK. BLKG. BM. B.N. BR. BRKR. BTCW. BTS. B.O.F. B/U C CAB. CANT. CB. COMA COUK C.I.P. CKT. CLG. CLR. CMU COL. CONC. CONN. CONST. CONT. d DBL. DC OEM. DEPT. D.F. DIA. OIAG. DIM. OWG. OWL. EA. EGR. EL ELEC. ELEV. AODITIONAL ABOVE FlNISHED FLOOR ABOVE FINISHED GRADE ABOVE GROUND LEVEL AMPERE INTERRUPTING CAPACITY ALUMINUM ALTERNATE ANTENNA APPROXIMATE(LY) ARCHITECT(URAL) AMPERE TRIP AMERICAN WIRE GAUGE BATTERY BOARD BUILDING BLOCK BLOCKING BEAM BOUNDARY NAILING BRANCH BREAKER BARE TINNED COPPER WIRE BASE TRANSMISSION SYSTEM BOTTOM OF FOOTING BACK-UP CABINET CONDUIT CABINET CANTILEVER(ED) CIRCUIT BRtAK'ER CODE-DIVISION MULTIPLE ACCESS (2G & 3G) CONSOLIDATION DISTRIBUTION UNIT KIT CAST IN PLACE CIRCUIT CEILING CLEAR CONCRETE MASONRY UNIT (JAMB BLOCKS) COLUMN CONCRETE CONNECTION(OR) CONSTRUCTION CONTINUOUS PENNY (NAILS) DOUBLE DIRECT CURRENT DEMAND DEPARTMENT DOUGLAS FIR DIAMETER DIAGONAL DIMENSION DRAWING(S) DOWEL(S) EACH EMERGENCY GENERATOR RECEPTACLE ELEVATION ELECTRICAL ELEVATOR 6 F FAS. FAC. F/A F.F. F.G. FIN. FLR. FLUOR FON. F.O.C. F.O.M. F.O.S. F.0.W. F.S. FT.(') FTG. FU G GR GA. GEN. GI. G.F.C. I. GLB. (GLU-LAM) GND GPS GRNO. GSM HDBC HOR. HGR. HPS HT. ICGB. IN.(") INT. LB.(#) L.B. L.F. LG. L. LPS LTE MAS. MAX. M.B. MECH. MFR. MIN. MISC. MLO MTD. MTG. MTL. I GROUT OR PLASTER (E) BRICK (E) MASONRY CONCRETE EARTH GRAVEL PLYWOOD SAND WOOD CONT. WOOD BLOCKING STEEL CENTERLINE PROPERTY /LEASE LINE MATCH LINE WORK POINT GROUND CONDUCTOR COAXIAL CABLE OVERHEAD SERVICE CONDUCTORS CHAIN LINK FENCING --T -- --T/E-- --G-- --so-- --w --s CJJ CH ErE E-<E---3 l-0 4=::f> OVERHEAD TELEPHONE/OVERHEAD POWER OVERHEAD TELEPHONE LINE K) OVERHEAD POWER LINE POWER RUN FIBER/POWER RUN ELECTRICAL METALLIC TUBING EDGE NAIL ENCLOSURE ENGINEER EQUAL EXISTING EXPANSION EXTERIOR FUTURE FABRICATION(OR) FACTOR FIRE ALARM FINISH FLOOR FINISH GRADE FINISH(ED) FLOOR FLUORESCENT FOUNDATION FACE OF CONCRETE FACE OF MASONRY FACE OF STUD FACE OF WALL FINISH SURFACE FOOT (FEET) FOOTING FUSE GROUND GROWTH (CABINET) GAUGE GENERATOR GALVANIZE(D) GROUND FAULT CIRCUIT INTERRUPTER GLUE LAMINATED BEAM GROUND GLOBAL POSITIONING SYSTEM GROUND Cl l-0 MTS. N fu~MA NO.(#) N.T.~·-OBIF OH o.c. OPNG. p P/C PCS PH PLY. PNLBD PPC PRC PRI P.S.F. P.S.I. P.T. PWR. QTY. RAD.(R) RBS RCPT. REF. REINF. REQ'D. RGS. RRU GLOBAL SYSTEM MOBILE (2G+ MOBILE TECH.) HARD DRAWN COPPER WIRE RX-AIT SAF SCH. SDBC SEC SHT. SIM. S.N. SPEC. SQ. HEADER HANGER HIGH PRESSURE SODIUM HEIGHT ISOLATED COPPER GROUND BUS INCH(ES) INTERIOR POUNO(S) LAG BOLfS LINEAR FEET (FOOT) LENGTH LONG(ITUOINAL) LOW t'RESSURt SODIUM LONG TERM EVOLUTION (4G MOBILE TECH.) MASONRY MAXIMUM MACHINE BOLT MECHANICAL MANUFACTURER MINIMUM MISCELLANEOUS MAIN LUGS ONLY MOUNTED MOUNTING METAL 5 S.S. STD. STL. STRUC. SURF SW TEL. TEMP. THK. TMAS T.N. T.0.A. T.0.C. T.O.F. T.O.P. T.O.S. T.0.W. TYP. I TELEPHONE LINE POWER/TELCO RUN GAS LINE GROUNDING CONDUCTOR STORM DRAIN WATER LINE SEWER LINE CONDUIT UNDERGROUND FUSE, SIZE AND TYPE AS INDICATED. SAFETY SWITCH, 2P-240V-60A W/60A FUSES, NEMA 3R ENCLOSURE, SQ O CATALOG NO. H222NRB MANUAL TRANSFER SWITCH, 2P-240V-200A, NO FUSE, NEMA 3R ENCLOSURE LIGHTING FIXTURE, FLUORESCENT, 10.94" x 4'-0", 2/40W, SURFACE MOUNTING TYPE, HUBBELL LIGHTING CATALOG #WSW232T LIGHTING FIXTURE. FLUORESCENT, 10.94" x a·-o·, 2/95W, SURFACE MOUNTING TYPE. HUBBELL LIGHTING CATALOG jTWSM232T LIGHTING FIXTURE, HIGH PRESSURE SODIUM, 1/70W, WALL MOUNTING TYPE, HUBBELL LIGHTING CATALOG #NRG-307 OR 1/50W, HUBBELL LIGHTING CATALOG #NRG-121 EXIT SIGN, THERMOPLASTIC LED, SINGLE FACE, UNIVERSAL MOUNTING, W/BATTERY PACK, HUBBELL LIGHTING CATALOG #PRB COMBINATION, EXIT SIGN & EMERGENCY LIGHTING, HUBBELL LIGHTING CATALOG #PRC EMERGENCY LIGHTING, 2/50W, HUBBELL LIGHTING CATALOG #HE6-50-2-R91 LIGHTING FIXTURE, INCANDESCENT, 1/100W, WALL MOUNTING TYPE, HUBBELL LIGHTING CATALOG #BRH-100-06-1 LIGHTING FIXTIJRE, HALOGEN, QUARTZ, 1/300W, HUBBELL LIGHTING CATALOG jOL-505 LIGHTING FIXTURE, 1/175W. METAL HALIDE, HUBBELL CAT #MIC-D 175H-336 5/8" X 1 D' -0" ,CU. GND ROD 3D" MIN. BELOW GRADE. MANUAL TRANSFER SWITCH NEUTRAL NEW NATIONAL ELECTRICAL MANUFACTURERS ASSOC. NUMBER NOT TO SCALE OPTICAL BASEBAND INTERFACE OVERHEAD ON CENTER OPENING POLE PRECAST CONCRETE PERSONAL COMMUNICATION SERVICES PHASE PLYWOOD PANELBOARD POWER PROTECTION CABINET PRIMARY RADIO CABINET PRIMARY POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH PRESSURE TREATED POWER (CABINET) QUANTITY RADIUS RADIO BASE STATION (BASE STATION 3G NETWORKS) RECEPTACLE REFERENCE REINFORCEMENT(ING) REQUIRED RIGID GALVANIZED STEEL REMOTE RADIO UNIT (RADIO TRANSCEIVER) RECEIVER AIR INTERFACE TRAY SAFETY SCHEDULE SOFT DRAWN BARE COPPER SECONDARY SHEET SIMILAR SOLID NEUTRAL SPECIFICATION(S) SQUARE STAINLESS STEEL STANDARD STEEL STRUCTURAL SURFACE SWITCH TELEPHONE TEMPORARY THICK(NESS) TOWER MOUNTED AMPLIFIER (DC SUPPLY VOLTAGE) tOE NAIL TOP OF ANTENNA TOP OF CURB TOP OF FOUNDATION TOP OF PLATE (PARAPET) TOP OF STEEL TOP OF WALL TYPICAL 4 U.G. U.L. UMTS U.N.O. V VAC V.I.F. w WO W/ W/0 wb. W.P. WT. WTR. XFER XFMR XLPE { e I i ~ ◄ s Ill I 5/8" X 10'-0" ,CU. GNO ROD IN TEST WELL 30" MIN. BELOW GRADE. CHEMICAL GROUND ROD (XIT GROUND ROD) HALO GROUND CONNECTION CIRCUIT BREAKER UTILITY METER BASE TRANSFORMER STEPDOWN TRANSFORMER RECEPTACLE, 2P-3W-125V-15A, DUPLEX, GROUND TYPE, HUBBEL CATALOG #5362 TOGGLE SWITCH, 1P-125V-15A, HUBBELL CATALOG #HBL 1201CN TOGGLE SWITCH, 1P-120V-15A, "WP" IONIZATION SMOKE DETECTOR W/ALARM HORN & AUXILIARY CONTACT, 120 VAC, CENTEX PART NO. 7100F POLE (N) POLE MOUNTED XFMR (E) POLE MOUNTED XFMR (N) PAO MOUNTED XFMR (E) PAO MOUNTED XFMR CLEARANCE FOR CABINET UNDER GROUND UNDERWRITERS LABORATORY INC. UNIVERSAL MOBIL TECH. SYS. (3G MOBILE TECH.) UNLESS NOTED OTHERWISE VOLT VOLT ALTERNATING CURRENT VERIFY IN FIELD WATT OR WIRE WIDE(WIDTH) WITH WITHOUT WOOD WEATHERPROOF WEIGHT WIRELESS TRANSMISSION RATE TRANSFER TRANSFORMER CROSS-LINK POLYETHYLENE CENTERLINE PLATE, PROPERTY LINE 3 GENERAL NOTES 1. THE FACILITY IS AN UNOCCUPIED DIGITAL TELECOMMUNICATION FACILITY. 2. PLANS ARE NOT TO BE SCALED AND ARE INTENDED TO BE A DIAGRAMMATIC OUTLINE ONLY, UNLESS NOTED OTHERWISE. THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 3. PRIOR TO THE SUBMISSION OF BIDS, THE CONTRACTORS SHALL VISIT THE JOB SITE AND BE RESPONSIBLE FOR ALL CONTRACT DOCUMENTS, FIELD CONDITIONS AND DIMENSIONS, AND CONFlRMING THAT THE WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION OF THE IMPLEMENTATION ENGINEER ANO ENGINEER PRIOR TO PROCEEDING WITH THE WORK. 4. THE CONTRACTOR SHALL OBTAIN, IN WRITING, AUTHORIZATION TO PROCEED BEFORE STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED OR IDENTIFIED BY THE CONTRACT DOCUMENTS. 5. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY INDICATED OTHERWISE OR WHERE LOCAL CODES OR REGULATIONS TAKE PRECEDENCE. 6. ALL WORK PERFORMED AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. MECHANICAL AND ELECTRICAL SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND STATE JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. 7. THE GENERAL CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK, USING THE BEST SKILLS AND ATTENTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT INCLUDING CONTACT AND COORDINATION WITH THE IMPLEMENTATION ENGINEER ANO WITH THE LANDLORD'S AUTHORIZED REPRESENTATIVE. 8. SEAL PENETRATIONS THROUGH FIRE RATED AREAS WITH U.L. LISTED AND FlRE CODE APPROVED MATERIALS. 9. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2-A10BC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF THE PROJECT AREA DURING CONSTRUCTION. 10. DETAILS ARE INTENDED TO SHOW END RESULT OF DESIGN. MINOR MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK. 12 11. REPRESENTATIONS OF TRUE NORTH, OTHER THAN THOSE FOUND ON THE PLOT OF SURVEY DRAWING, SHALL NOT BE USED TO IDENTIFY OR ESTABLISH THE BEARING OF TRUE NORTH AT THE SITE. THE CONTRACTOR SHALL RELY SOLELY ON THE PLOT OF SURVEY DRAWING AND ANY SURVEYOR'S MARKINGS AT THE SITE FOR THE ESTABLISHMENT OF TRUE J3 NORTH, AND SHALL NOTIFY THE ENGINEER PRIOR TO PROCEEDING WITH THE WORK IF ANY DISCREPANCY IS FOUND BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS AND THE TRUE NORTH ORIENTATION AS DEPICTED ON THE CIVIL SURVEY. THE CONTRACTOR SHALL ASSUME SOLE LIABILITY FOR ANY FAILURE TO NOTIFY THE ENGINEER. 12. THE CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS, PAVING, CURBS, VEGETATION, GALVANIZED SURFACES, ETC., ANO UPON COMPLETION OF WORK REPAIR ANY DAMAGE THAT OCCURRED DURING CONSTRUCTION TO THE SATISFACTION OF AT&T. 13. KEEP GENERAL AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DIRT, DEBRIS, RUBBISH AND REMOVE EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY. LEAVE PREMISES IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST OR SMUDGES OF ANY NATURE. 14. BEFORE ORDERING AND/OR BEFORE FABRICATING/CONSTRUCTING/INSTALLING ANY ITEMS, VERIFY THE TYPES AND QUANTITIES. 15. CONTRACTOR SHALL PROVIDE SITE FOREMAN WITH A CELLULAR PHONE AND KEEP SAME ON SITE WHENEVER PERSONNEL ARE ON SITE. 16. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS ON THE SITE AND NOTIFY THE PROJECT MANAGER OF ANY DISCREPANCIES BEFORE STARTING ANY WORK. 17. CONTRACTOR TO PROVIDE COMPLETE SET OF AS BUILT DRAWINGS WITHIN 10 WORKING DAYS OF PROJECT COMPLETION. 18. PRIOR TO THE COMMENCEMENT OF CONSTRUCTION OR THE FABRICATION OF MATERIALS TO BE INSTALLED AT THE SITE, THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS INCLUDING AS-BUILT DIMENSIONS OF EXISTING STRUCTIJRES OR STRUCTURAL ELEMENTS HAVING A BEARING ON THE SCOPE OF THE WORK TO BE PERFORMED. IF ANY DISCREPANCY IS FOUND BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS AND THE DIMENSIONS OR CONDITIONS FOUND TO BE EXISTING IN THE FIELD, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND OBTAIN DESIGN RESOLUTION PRIOR TO PROCEEDING WITH THE PORTION(S) OF THE WORK AFFECTED. THE CONTRACTOR SHALL ASSUME SOLE LIABILITY FOR ANY FAILURE TO SO NOTIFY THE ENGINEER AND OBTAIN RESOLUTION BEFORE PROCEEDING. 19. CONTRACTOR TO RETURN (E) STREET LIGHT AND LIGHT ARM TO THE CITY OF NEWPORT BEACH UTILITIES YARD. IF DAMAGED DURING THE REMOVAL, CONTRACTOR SHALL BE REQUIRED TO PURCHASE AND DELIVER A REPLACEMENT. CITY OF NEWPORT BEACH UTILITIES YARD: 949 W. 16TH STREET NEWPORT BEACH CA 92663. CONTRACTOR SHALL DISPOSE OF THE EXISTING STREET LIGHT POLE AND ARMS IF UNWANTED BY THE CITY FOR ANY REASON. 11 I 2 I APPLICANT: 1452 EDINGER AVENUE, 3rd FLOOR TUSTIN, CA 92780 ENGINEER: -BECHTEL INFRASTRUCTURE AND POWER CORPORATION 168D8 ARMSTRONG AVENUE, SUITE 225, IRVINE, CA 92606 l°RAWN BY: CHECKED BY: D - t,--..... --..,.--R•E-v_1s.1o_N_s_, ____ _,, __ ,t c 1 05/26/21 0 07/15/20 A 06/05/20 REV DATE REVISED PER CITY COMMENTS ISSUED FOR PERMIT/ CONSTRUCTION ISSUED FOR REVIEW DESCRIPTION SB SAS SRR BY I--------L-IC•E•N•S•E•R•:--------1.- PROJECT INFORMATION: NWPTB NODE 015A 1991 PORT EDWARD CIR NEWPORT BEACH, CA 92660 BECHTEL DRAWING NUMBER 26134-617-C0-0000-01032-001 SHEET TITLE: LEGEND, ABBREVIATIONS AND GENERAL SHEET NUMBER: T-2 B - A PA2021-123 NEWPORl CENTER Rog~rs Gar<lRns Q Pl~z;i 9 Shorniar, L1brocy & Gnrdens Blltk Gully R~,:~;v,, NOTES, (i_) CORONA DEL MAR VICINITY MAP 0 ~IS IS NOT A BOUNDARY SURVEY. THIS IS A SPECIALIZED TOPOGRAPHIC MAP. THE PROPERTY LINES AND EASEMENTS SHOWN HEREON ARE FROU RECORD INFORMATION AS NOTED HEREON. A.JK EhGl'EER hG ANJ SURVEY TRANSLATED THE TOPOGRAPHIC SURVEY TO RECORD INFORMATION USING FOUND MONUMENTS SHOWN HEREON. 2. THE HEIGHTS AND ELEVATIONS FOR TH[ TREES, BUSHES ANO OIH[R LIVING PLANTS SHOWN HEREON, SHOULD BE CONSIDERED APPROXIMATE (+/-) ANO ONLY FOR THE OAT[ OF [HIS SURVEY. THEY ARE PROVIDED AS A GENERAL REFERENCE ANO SHOULD NOT BE USED FOR DESIGN PURPOSES. J. FIELD SURVEY COMPLETED ON 1E:c>IEFR I . , 2C 19 4. RIGHT or WAY WAS ESTABLISHED BY LOCATltlG FOUND CENTERLINE CITY OR COUNTY MONUIJENTS. 5. If CENTERLINE IJONUM[NTS WERE NOT LOCATABLE, THE CENTERLINE OFFSET TIES WERE USED TO ESTABLISH THE IIHERSECTIONS. 6. If NEITHER C[Nl[RLIN[ TIES OR C[Nf[RUN[ INTERSECflON MONUMENTS WERE LOCATABLE, EXISTING IMPROVEM[NfS WERE USED TO [STABLISH RIGHTS Of WAY. 7. All SHOWN RIGHTS OF WAY WERE BASED UPON RESEARCH AT COUNTY OR CITY fll[S ANO REFLECT TH[ LAT[Sf RECORDED MAPS, RECORDS Of SURVEY, PARCEL MAPS OR OTHER RECORDS. RIGHTS Of WAY Will NOf R[fl[Cf ANY DEDICATION, fAK[N OR OFFERED AFTER THE RECORD MAP USED. All SURVEYS WERE COMPLETED WITHOUT THE BENEFIT Of A CURRENT TITLE R[PORI ANO MAY NOT SHOW ADDITIONAL DEDICATIONS NOT SHOWN ON fH[ RECORD IMPS USED. NI LEGEND BASIS OF BEARING REFERENCE: I. TRACT NO. 70J I RECOROED OAT[ APRIL 8, 1971 BOOK 277 PAGE 21-24 2. TRACT NO. 7030 RECORDED OAT[ JULY 2. 1970 BOOK 269 PAGE 18-22 CENTER LINE ------PROPERTY UN[ ---o---:i-------WROUGHf IRON FENCE ·------•-•·---CMU WALL BFP BACK FLOW PREVENTER Bl'/ BACK or WALK CB CAfCH BASIN EG EXISTING GRADE EP EDGE Of PAVEMENT FS FINISH SURFACE GV GAS VALVE HH HANOHOLE JB JUNCTION BOX 0 MH MANHOLE TC TOP Of CURB Tl TOP Of LIGHT POLE T\'I TOP Of VIALL SCALE: 1:100 VL VAULT VT V['1T OVERALL SITE PLAN VIM WATER METER VN WATER VALVE ------------ C,-----0 EXISTING STREET LIGHT EXISTING TRAFFIC SIGNAL _o_ EXISTING SIGN E-----GUY \'/IRE ____Q__ POWER POLE 'T:f FIRE HYDRANT -'''i-:· > .. ,,. ~ TREE EXISTING CONCRETE EXISTING GRASS/TURF MONUMENTS @ t-.!ONUMEMT f"D. ~~~~5o; ~~l~l (27'-2"-A.c_G'.l~)---------/,---'"-,'Y ------- /'-- ~ I V I ~ ELEVATION / 285.16' A.M.S.l (26'-9"A.G.L~ 'ct/ I ~11 ---------- DETAIL "B" APN 458-284-06 -, CABINET ISSUE STATUS REV. DATE DESCRIPTION 12/13119 FINAL SURVEY 23072 LAKE CENTER OR., SUITE 211 LAKE FOREST, CA 92630 714.624.9027 BY LJ PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO AT&T ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T IS STRICTLY PROHl8lTEO Lt) ,- ...J cc (..) .... en a. == z SHEET TITLE: TOPOGRAPHIC SURV[Y LS-1 PA2021-123 C ~ ~ >-0 t: a. 0 a a.,3 w .c C O> ·c·;;: c • 0 .c u - NOTES: 1. IF DIMENSIONS SHOWN ON PLAN DD NOT SCALE CORRECTLY, CHECK FOR REDUCTION OR ENLARGEMENT FROM ORIGINAL PLANS. 2. UTILITY DESIGN ANO RUNS ARE PRELIMINARY. PENDING FINAL DESIGN FROM UTILITY PROVIDERS. 3. PULL BOXES AND LIDS SHALL BE SPECIFIED AS CONCRETE OR APPROVED EQUAL. 4. REMOVE EXISTING LIGHT POLES AND LIGHT BASE. REPLACE PARKWAY AND/OR SIDEWALK, IN KIND. 5. CONTRACTOR TO PROTECT IN PLACE ALL SEWER AND WATER LATERALS WHICH CROSS UNDER/OVER THE PROPOSED ELECTRICAL TRENCHING. 6. ALL NEW LIGHT POLES SHALL RECEIVE A COATING TO PROTECT AGAINST GRAFFITI. 7. GENERAL CONTRACTOR SHALL RE-LOCATE ANY SIGNS ON EXISTING LIGHT POLE TO A NEW LIGHT POLE. 8. EDGE OF NEW ASPHALT PATCH IS A MINIMUM OF 1-FOOT FROM THE EDGE THE TRENCH, ON BOTH SIDES. NEW ASPHALT SHALL BE PLACED (1-INCH) THAN THE EXISTING ASPHALT, AND A MINIMUM OF 4" THICK. REPLACE IN KIND. 9. WHERE THE EDGE OF NEW ASPHALT PATCH IS WITHIN 2-FEET OF THE EDGE OF GUTTER ALL EXISTING ASPHALT FROM THE EDGE OF GUTTER TO THE EDGE OF TRENCH SHOULD BE REMOVED AND REPLACED. IN THE FIELD THIS IS REFERRED TO AS A 2 FOOT FLOATER. 10. CONTRACTOR TO VERIFY SUB STRUCTURE LOCATIONS PRIOR TO ANY EXCAVATION. 11 . ALL CONDUCTORS/WIRES & CONDUIT, SHALL BE INSTALLED IN A NEAT AND TIDY FASHION. ALL EXCESS WIRE SLACK IS TOO BE REMOVED AND HIDDEN AS MUCH AS POSSIBLE. 12. ALL NEWLY INSTALLED EQUIPMENT SHALL BE PAINTED TO MATCH EXISTING POLE, AND OR SURROUNDINGS. UNLESS PROHIBITED BY MANUFACTURER. SURVEY NOTE: 1. THE PROPERTY LINE SHOWN HAS BEEN CREATED WITHOUT THE BENEFIT OF A SURVEY AND IS FOR REFERENCE ONLY. ALL PROPERTY LINES, EASEMENTS AND SETBACKS SHALL BE VERIFIED PRIOR TO START OF CONSTRUCTION. BECHTEL DOES NOT GUARANTEE THE ACCURACY OF SAID PROPERTY LINES, EASEMENTS, ROADS AND SETBACKS. THIS SITE PLAN IS NOT A SURVEY AND IS PROVIDED FOR INFORMATION ONLY CITY OF NEWPORT BEACH NOTES 1. AN APPROVED ENCROACHMENT PERMIT ID REQUIRED FOR ALLWORK ACTIVITIES WITHIN THE PUBLIC RIGHT-OF-WAY. 2. CONTRACTOR SHALL PROVIDE LANE CLOSURE PLANS PER WATCH HANDBOOK AND STATE OF CALIFORNIA DEPARTMENT OF TRANSPORTATION STANDARDS. 3. CONTRACTOR TO RETURN (E) STREET LIGHT AND LIGHT ARM TO THE CITY OF NEWPORT BEACH UTILITIES YARD. IF DAMAGED DURING THE REMOVAL, CONTRACTOR SHALL BE REQUIRED TO PURCHASE AND DELIVER A REPLACEMENT. CITY OF NEWPORT BEACH UTILITIES YARD: 949 W. 16TH STREET NEWPORT BEACH CA 92663. CONTRACTOR SHALL DISPOSE OF THE EXISTING STREET LIGHT POLE AND ARMS IF UNWANTED BY THE CITY FOR ANY REASON. 4. WHEN REMOVED OR DAMAGED BY CONSTRUCTION, ALL CURB, GUTTER AND SIDEWALK SHALL BE REPLACED IN ENTIRE SECTIONS BETWEEN EXPANSIONS JOINTS. NO SAW CUTTING AND PARTIAL PATCHING SHALL BE PERMITTED. ALL CONSTRUCTION DETAILS FOR REPLACEMENT SECTIONS SHALL BE PER CITY OF NEWPORT BEACH STANDARD DRAWINGS. 5. THE CONTRACTOR SHALL REPAIR, REPLACE OR RE-ROUTE ALL LANDSCAPE, IRRIGATION LINES AND FIXTURES AN KIND INCLUDING LINE SIZE, HEAD TYPE, SPACING AND CONTROL WHERE DAMAGED BY CONSTRUCTION TO THE SATISFACTION OF THE CITY OF NEWPORT BEACH. 6. THE CONTRACTOR SHALL REPLACE ALL EXISTING GROUNDCOVER, INCLUDING SAND AND ALL OTHER LANDSCAPING INCLUDING TURF, SHRUBS, AND/OR TREES IN KIND INCLUDING SIZE, SPECIES AND SPACING WHERE DAMAGED BY NEW CONSTRUCTION TO THE SATISFACTION Of THE CITY Of NEWPORT BEACH. 7. DIRTY OR DAMAGED STREET SIGNS SHALL BE REPLACED BY THE CONTRACTOR. DIG ALERT UNOERCROUHO SEJMCE .Al..£RT Of SOOJliERN CJ,Lf"ORNIA DIAL TOLL FREE 1-800-277-2600 6 AT LEAST TWO DAYS BEFORE YOU DIG 12" WATER LINE 16' N FROM C/L 8" WATER LINE 16' N FROM C/L A.P.N: 458-294-04 \ \ ~ --F--FIBER OPTIC CABLE --F/E--FIBER / ELECTRICAL LINE --E --ELECTRICAL LINE C&G CURB & GUTTER -----CENTER LINE DWY DRIVEWAY C/L CENTER LINE @ MANHOLE 5 ~ ()<¢- . / --;? / ~'v ~~ .// / ~«. :::::·· x ~<,:; . / c:, V+ -- (E) C&G 3" GAS LINE I5'-0" S OF C/L A.P.N: 458-284-03 (N) AT&T PROJECT LOCATION SEE ENLARGED SITE PLAN ---------·t ~ 9"X14" PULL BOX r, '--~ (E) (E) ADA RAMP A.P.N: 458-284-04 ·····.,.. ~-.,,_-(E) '·. SITE PLAN 4 PULL BOX 2" GAS LINE 34'-Q" E OF C/L 48" OD WATER LINE 16' S FROM C/L--~ 24" ID WATER LINE 16' S FROM C/L---~ 3 LEGEND: --E --ELECTRICAL LINE ---G---GAS LINE --SO---STORM DRAIN --T --TELEPHONE LINE --W ---WATER LINE --S ---SEWER LINE --F --FIBER OPTIC CABLE -----CENTERLINE --F /E--FIBER / ELECTRICAL LINE @ WATER VALVE C&G CURB & GUTTER OWY DRIVEWAY C/L CENTERLINE MH MANHOLE SEWER MH STORM DRAIN MH GAS VALVE MANHOLE ID WATER INDUSTRIAL WATER LINE DO WATER DOMESTIC WATER LINE FULL SCALE 3" CSG GAS LINE 13'-Q" N OF C/L 'l 1"=20'-o" 1 20 10 0 20 40 FT /"I HALF SCALE 1 "=40'-0" 2 APPLICANT: at&t Mobility 1452 EDINGER AVENUE, 3rd FLOOR TUSTIN, CA 92780 ENGINEER: D BECHTEL INFRASTRUCTURE_ AND POWER CORPORATION 16808 ARMSTRONG AVENUE, SUITE 225, IRVINE, CA 92606 (DRAWN BY: CHECKED BY: .--,,---,,--R-E_v_1s_1o_N_s, ____ T""_1 c 0 A REV 05/26/21 REVISED PER CITY COMMENTS 07/15/20 ISSUED FOR PERMIT/ CONSTRUCTION 06/05/20 ISSUED FOR REVIEW DATE DESCRIPTION LICENSER: PROJECT INFORMATION: NWPTB NODE 015A 1991 PORT EDWARD CIR NEWPORT BEACH, CA 92660 BECHTEL DRAWING NUMBER 26134-61 7-C0-0000-01032-001 SHEET TITLE: SITE PLAN SHEET NUMBER: A-1 SB SAS SRR BY B A PA2021-123 C .!! e >-0 t: a. 0 ~ a.8 LEGEND: -- E --ELECTRICAL LINE ---G---GAS LINE --SD--STORM DRAIN --T --TELEPHONE LINE --W --WATER LINE --S --SEWER LINE -- F --FIBER OPTIC CABLE -----CENTERLINE --F /E--FIBER / ELECTRICAL LINE Q9 WATER VALVE C&G CURB & GUTTER DWY DRIVEWAY C/L CENTERLINE MH MANHOLE (N) 17"X30" FIBER PULL BOX TO .liQIES;, 1. PULL BOXES TO BE CONSTRUCTED PER STD-204-L. 2. THE PROPOSED HAND HOLES ARE PROVIDED BELOW GRADE & FLUSHED WITH TOP SURFACE • 3. LANDSCAPING TO BE REPLACED IN KIND. 4. ALL GROUND BOXES, PULL BOX AND WIRE ACCESS COVERS SHALL HAVE TEMPER RESISTANT/VANDAL PROOF STAINLESS STEEL HARDWARE. 5. CONTRACTOR/AT&T SHALL BE RESPONSIBLE FOR EXISTING CONDUIT, WIRE OR CIRCUIT MODIFICATIONS OR DAMAGE TO "CITY" PROPERTY. 6. ANY REPAIR WORK SHALL MATCH (E) SLOPE PER STD-180-L DETAIL 7. SIGNAGE SHALL HAVE GRAFFITI COATING. @ SEWER MH BE INSTALLED BY AT&T WIRELINE -------------~ 8. ALL FASTENING HARDWARE SHALL BE STAINLESS STEEL AND HAVE ANTI SEIZE COMPOUND APPLIED LIBERALLY. 9. ALL WIRE ACCESS POINTS, GROUND BOXES, POLE HAND HOLES ETC., WITHIN THE PUBLIC REACH SHALL HAVE TAMPER RESISTANT ANTI-THEFT STAINLESS @ STORM DRAIN MH ~ ~ @ GAS VALVE @ MANHOLE / / / (N) 2"111 CONDUIT WITHIN (N) FIBER TRENCH FROM AT&T FIBER HH TO STREET LIGHT FOUNDATION (APPROX. 20' -0") @ (1) (N) 1-1/2"111 CONDUIT FOR POWER PULL BOX (WTR/FSB) & 1 "Ill CONDUIT FOR STREETLIGHT POWER WITHIN (N) POWER TRENCH ROUTED TO (N) POLE LOCATION (APPROX. 14' -0") @ C, ~ / / (N) 1 •111 CONDUIT FOR POWER WITHIN c, (N) POWER TRENCH ROUTED TO (N) POLE LOCATION (APPROX. 8' -0") / / / (N) OMNI ANTENNA TO BE INSTALLED M WITHIN CONCEALMENT SHROUD ON TOP ~ ~ c, OF THE (N) STREET LIGHT POLE ~/ 00 G / (1) (N) RRUS-4449 85/812 WITH (2) (N) / / , /4 PSU AC 08 UNITS, (1) (N) RRUS-4415 825 WITH (1) (N) PSU AC 08 UNIT & (1) (N) ,, ~ SPD UNIT WITHIN (N) POLE BASE PEDESTAL.~· ~ / ~ C, (E) 9"X14" PULL BOX ---------r~-------.. c, / / 3" GAS LINE '5'-0" S OF C/L \ :, / / / / I I I I I I / DIG ALERT / / / / "' ·-!,, "' / ---- lmOERGROUND SCR'Y1CC N.£Rl Of SOUTIOH CAU'ORNIA DIAL TOLL FREE 1-800-277-2600 AT LEAST TWO DAYS BEFORE YOU DIG ENLARGED SITE PLAN 6 5 4 STEEL FASTENERS. <" +-~~ "' ~ 0-<::J <" ,,, " '/ O• ,, ~~ v ,t, "' ;i-,,,.' ,, .,, "' "' ,J, "' "' "---:GI~-(N) 17"X30" SCE PULL BOX (TO BE INSTALLED BY AT&T) "' "' 00 --.,,L---=--(N) 17"X30" AT&T POWER / ,/ PULL BOX (WTR/FSB) INSTALLED BY AT&T MOBILITY ~ ~ / A.P.N: 458-284-03 --- A.P.N: 458-284-04 "-----a.,___ REMOVE (E) CONCRETE STREET LIGHT POLE AND INSTALL (N) STEEL STREET LIGHT POLE ON (N) POLE FOUNDATION AT SAME LOCATION PER MANUFACTURER'S SPECIFICATIONS (TO BE INSTALLED BY AT&T MOBILITY) AT 1991 PORT EDWARD CIR ~ ~ (E) CMU BLOCK WALL 3 2 2' FULL SCALE 0 e ■-- HALF SCALE 1 3/8"=1'-o" 4 6 FT 3/16"=1'-o" APPLICANT: 1452 EDINGER AVENUE, 3rd FLOOR TUSTIN, CA 92780 ENGINEER: D BECHTEL INFRASTRUCTURE_ AND POWER CORPORATION 16808 ARMSTRONG AVENUE, SUITE 225, IRVINE, CA 92606 (DRAWN BY: CHECKED BY: 1 0 A REV REVISIONS: 05126121 REVISED PER CITY COMMENTS 07115120 ISSUED FOR PERMIT/ CONSTRUCTION 06105/20 ISSUED FOR REVIEW DATE DESCRIPTION LICENSER: PROJECT INFORMATION: NWPTB NODE 015A 1991 PORT EDWARD CIR NEWPORT BEACH, CA 92660 BECHTEL DRAWING NUMBER 26134-617-C0-0000-01032-001 SHEET TITLE: ENLARGED SITE PLAN SHEET NUMBER: A-2 C SB SAS SRR BY B A PA2021-123 NOTE: 1. ALL CONDUCTORS/WIRES & CONDUIT, SHALL BE CONCEALED INSIDE (N) POLE ANO SHROUDED. 2. ALL NEWLY INSTALLED EQUIPMENT SHALL BE PAINTED TO MATCH EXISTING POLE, AND OR SURROUNDINGS. UNLESS PROHIBITED PER MANUFACTURER REQUIREMENTS 3. ALL THE SIGNAGES ON THE (E) STREET LIGHT POLE SHALL BE RELOCATED ONTO THE (N) STREET LIGHT POLE AT SAME LEVEL, GC TO REPLACE THE SIGNAGES IF DIRTY OR DAMAGED. 4. STRUCTURAL ANALYSIS AND DESIGN OF (N) STEEL POLE TO BE DONE BY CONCEALFAB. 5. THE CAVITY AROUND THE NEW FOOTING SHALL BE BACKFILLED WITH 1-SACK SLURRY OR CLASS 2 BASE AND COMPACTED TO 95% COMPACTION. 6. SIGNAGE SHALL HAVE GRAFFITI COATING. 7. ALL FASTENING HARDWARE SHALL BE STAINLESS STEEL ANO HAVE ANTI SEIZE COMPOUND APPLIED LIBERALLY. 8. ALL WIRE ACCESS POINTS, GROUND BOXES, POLE HANO HOLES ETC., WITHIN THE PUBLIC REACH SHALL HAVE TAMPER RESISTANT ANTI-THEFT STAINLESS STEEL FASTENERS. $ TOP OF (N) AT&T ANTENNA ELEV. 30'-1" (A.G.L) (N) AT&T ANTENNA----------~-, (N) CABLE CONCEALMENT SHROUD ------~'11, $ BOTTOM OF (N) RF NOTICE SIGNAGE ELEV. 24'-0" (A.G.L) JETTISON SHROUD (F) 5G LOCATION s'-o" LUMINAIRE TO MATCH EXISTING PER CITY STANDARDS TOP OF JETTISON SHROUD ELEV. 23'-9" (A.G.L) BOTTOM OF JETTISON SHROUD ELEV. 21'-6" (A.G.L) (N) STREET LIGHT POLE DESIGN REQUIREMENTS: = = ____ ~ .QF ~R_ATTACHME~T __ 4)....,._ ELEV. 18'-4" (A.G.L) '1" 1. INSIDE RISER FOR POWER+GROUNOING ------------t-1· (E) CONCRETE POLE TO BE REMOVED AND INSTALL (N) STEEL STREET LIGHT POLE II 3454 ON (N) POLE FOUNDATION AT THE SAME LOCATION. (TO BE INSTALLED BY AT&T MOBILITY) (SEE NOTE 4) _________ __, ~ TOP OF RELOCATED (E) SIGNAGE ELEV. 11'-11" (A.G.L) TOP OF RELOCATED (E) SIGN AGE ELEV. 10 -8 A.G.L = = ____ ~ _QF BANNER_ATTACHME~T __ ,..,4) __ ELEV. 10'-4" (A.G.L) '1" BOTTOM OF RELOCATED (E) SIGN AGE ELEV. 9 -8 A.G.L (1) (N) RRUS-4449 85/812 WITH (2) (N) PSU AC 08 UNITS, ( 1 ) (N) RRUS-4415 825 WITH (1) (N) PSU AC 08 UNIT & (1) (N) SPD UNIT WITHIN (1) (N) POLE BASE PEDESTAL ~ (REFER DETAIL 3 SHEET A-6) \ ,\ 4'-10" TOP OF PEDESTAL ELEV. 3'-10" (A.G.L) (E) CURB & GUTTER TOP OF (E) CURB ELEV. o'-o" (E) SHRUBS/BUSHES AREA (GC TO REPLACE THE DISTURBED LANDSCAPE AND SHRUBS IN KIND) :~ t t / \ _ _:,: 9"X14" PULL BOX o f\J (N) FOUNOATION TO BE BOTTOM OF NEW CAISSON L..:::::'.L:i------lNSTALLED BY AT&T MOBILITY .....,,-.c..EL~E-V.-6'---9~--8-EL_O_W-GR_A_D_E ________ ~--~ (REFER SHEET UD-2) FULL SCALE 3/8"=1'-o" 2 ~ 0 2 4 6 ~ PROPOSED NORTHEAST ELEVATION l'!!il'i il"'il~liiiiiiii~§~~-l! ......... ~ HALF SCALE 3/16"=1'-o" 6 5 4 $ TOP OF (N) AT&T ANTENNA ELEV. 30'-1" (A.G.L) ___ RAO CEN;IJcR. OF (N)_J\T&T ANTE_tlN..A..itL (N) AT&T ANTENNA----------~-11 ELEV. 29 -1 (A.G.L) -~ __ _ C/L OF l,_UMINAIRE ____ ____.t-,__ (N) CABLE CONCEALMENT SHROUD---------1-ll.. ELEV. 28'-0" (A.G.L) ------q,- JETTISON SHROUD (F) 5G LOCATION LUMINAIRE TO MATCH EXISTING PER CITY STANDARDS TOP OF JETTISON SHROUD ELEV. 23'-9" (A.G.L) BOTTOM OF JETTISON SHROUD ELEV. 21'-6" (A.G.L) ___ __Q,LL._01:_ BANNER A_TTACHMENT_ ~ ELEV. 18'-4" (A.G.L) ~ (E) CONCRETE POLE TO BE REMOVED AND INSTALL (N) STEEL STREET LIGHT POLE II 3454 ON (N) POLE FOUNDATION AT THE SAME LOCATION. (TO BE INSTALLED BY AT&T MOBILITY) (SEE NOTE 4)--------------i ~ TOP OF RELOCATED (E) SIGNAGE ELEV. 11'-11" (A.G.L) __di.___ilL OF BANNER ATTACHMENT _____ _ -v-ruv. 10'-4" (A.G.L) . (N) 1 "l'l CONDUIT FOR POWER WITHIN (N) POWER TRENCH ROUTED TO (N) POLE LOCATION ---------~ (N) 1-1/2"¢ CONDUIT FOR POWER PULL BOX (WTR/FSB) & 1 "l'l CONDUIT FOR STREETLIGHT POWER WITHIN (N) POWER TRENCH ROUTED TO (N) POLE LOCATION (N) SCE PULL BOX (N) AT&T FIBER PULL BOX 6'-o" ··r,=~- -c-~.<\~ < '{ ~-'t fi-~ ~ ,; ~ :':. (N) 2"1'l CONDUIT WITHIN ~\. (1 I "' (N) FIBER/POWER GROUND ROD STAINLE °f.J_'._-{ TRENCH ROUTED TO (N) STEEL #6 SOLID COP 1·+-:·t·· POLE LOCATION INSULATED WITH t·L:o· _: EXOTHERMIC CONNECTION--I .1 , ___ _ (N) AT&T POWER PULL BOX (WTR/FSB) ----~ ELEV. 10'-8" (A.G.L) BOTTOM OF RELOCATED l(E) SIGNAGE ~ ELEV. 9' -8" (A.G.L) (1) (N) RRUS-4449 85/812 WITH (2) (N) PSU AC 08 UNITS, ( 1) (N) RRUS-4415 825 WITH (1) (N) PSU AC 08 UNIT & (1) (N) SPD UNIT WITHIN (1) (N) POLE BASE PEDESTAL (REFER DETAIL 3 SHEET A-6) TOP OF PEDESTAL ELEV. 3'-10" (A.G.L (E) CURB & GUTTER TOP OF (E) CURB ELEV. 0 -0 ' · (t) SHR~Bs/Bi:JSHES AREA (GC TO REPLACE THE DISTURBED LANDSCAPE AND SHRUBS IN KIND) (N) FOUNDATION TO BE INSTALLED BY AT&T MOBILITY (REFER SHEET UD-2) BOTTOM OF NEW CAISSON A ELEV. 6'-9 BELOW GRADE V 1 2' FULL SCALE 0 3/8"=1'-o" PROPOSED NORTHWEST ELEVATION "' 2 4 6 ~ ~ i----, HALF SCALE 3/16"=1'-o" 3 2 APPLICANT: at&t Mobility 1452 EDINGER AVENUE, 3rd FLOOR TUSTIN, CA 92780 ENGINEER: - D BECHTEL INFRASTRUCTURE,_. AND POWER CORPORATION 16808 ARMSTRONG AVENUE, SUITE 225, IRVINE, CA 92606 (DRAWN BY: CHECKED BY: 1----,----,--R_E_v1_s1_0N_s_: ----r----1 C 1 0 A REV 05/26/21 REVISED PER CITY COMMENTS 07/15/20 ISSUED FOR PERMIT/ CONSTRUCTION 06/05/20 ISSUED FOR REVIEW DATE DESCRIPTION LICENSER: PROJECT INFORMATION: NWPTB NODE 015A 1991 PORT EDWARD CIR NEWPORT BEACH, CA 92660 BECHTEL DRAWING NUMBER 26134-617-C0-0000-01032-001 SHEET TITLE: ELEVATIONS SHEET NUMBER: A-3 SB SAS SRR BY B A PA2021-123 0 C -0 -j 0 " C 5 -" a. -C 0 • : E j ] g .c,:, u . " CD£ 0 -C j'.-:;; E • • C LO a.-0 C L 0 a. u C C 0 0 t1i H i! .,, " ~::, O 0 u- " .c ]~ C 0 0 .c u - SITE IMAGE 2 6 5 4 ~ TOP OF (E) SIGNAGE ELEV. 11'-11" (A.G.L) (E) CURB & GUTTER ---~ TOP OF (E) ELEV. 0 -0 (E) 9"X14" PULL BOX a'-o" C/L OF (E) LUMINAIRE __ ni. ------ELEV 28 -6'' (A.G.Lf --------V- TOP OF (E) CONCRETE STREET LIGHT POLE ~ ELEV. 27'-2" (A.G.L) (E) CONCRETE STREET LIGHT POLE #3454 (TO BE REMOVED) l!i ELEV. 10'-8" (A.G.L) ~ \ BOTTOM OF (E) SIGNAGE TOP OF (E) SIGNAGE J ELEV. 9'-8" (A.G.L) I I I I I I I I I : I : I c-.------g-•;_i_: ___ ,,----=--j /(E) ROW ~ t-2" V 4'-10" I I GRADE LEVEL FULL SCALE EXISTING SOUTHWEST ELEVATION 2' 0 2 ,.. HALF SCALE 3 2 1 3/8"=1'-o" 4 6 FT ,......... 3/16"=1'-o" APPLICANT: at&t Mobility 1452 EDINGER AVENUE, 3rd FLOOR TUSTIN, CA 92780 ENGINEER: " BECHTEL INFRASTRUCTURE AND POWER CORPORATION 16808 ARMSTRONG AVENUE, SUITE 225, IRVINE, CA 92606 (°RAWN BY: CHECKED BY: D ..,_ ______ RE_v_Is_Io_N_s._· ------1 c 0 A REV 05/26/21 REVISED PER CITY COMMENTS 07/15/20 ISSUED FOR PERMIT/ CONSTRUCTION 06/05/20 ISSUED FOR REVIEW DATE DESCRIPTION LICENSER: PROJECT INFORMATION: NWPTB NODE 015A 1991 PORT EDWARD CIR NEWPORT BEACH, CA 92660 BECHTEL DRAWING NUMBER 26134-617-C0-0000-01032-001 SHEET TITLE: SB SAS SRR BY B SITE IMAGE & ELEVATION A SHEET NUMBER: A-4 PA2021-123 C 0 "' ~ >-0 t: 0. 0 L o.8 NEW FOUNDATION PER MANUFACTURER SPECIFICATIONS (TO BE INSTALLED BY AT&T) ,,.-/ n (1) NEW OMNI ANTENNA ON TOP OF NEW CONCEALMENT / Ir--:::='"-, I \"-I __ ,,,, (1) NEW LUMINAIRE PEJ UTILITY REQUIREMENTS -EXISTING CURB NEW OMNI ANTENNA EB1 MOUN TED ON TOP OF CONCEALMENT SHROUD. ------POLE TOP CONCEALMENT BY CONCEALF AB (N) s·xs· RF s1GNAGE EB (REFER SHEET A-3 DETAIL # 2 8 FOR HEIGHT OF ATTACHMENT) - JEmSON SHROUD (F) 5G LOCA TlON (N) FUTURE BANNER & BRACKET LOCATION BY OTHERS (TYP) EB NEW STEEL POLE @ ® ---(N) CONDUIT FOR POWER ANO GROUNDING WITHIN ---(N) POLE PEDESTAL @ GRADE LEVEL t:-tt--tt-~· ;·-----NEW FOUNDATION PER POLE DETAIL 6 NOTES: MANUFACTURER SPECIFICATIONS (TO BE INSTALLED BY AT&T MOBILITY) @ 1. POLE BY CONCEALFAB OR APPROVED EQUAL. 2. NEW WIRING AND CONDUIT PER UTILITY REQUIREMENTS l:!QKS; 1. AFFIX REQUIRED SIGNAGE AT POLE TOP ON THE SUPPORT STRUCTURE SO THAT, IT WILL BE CLEARLY VISIBLE: A. INSTALL 3-4 FEET BELOW ANTENNA (MEASURED FROM TOP OF SIGN) 2. SIGNS OR DECALS SHALL BE MADE OF WEATHER, CORROSION AND ULTRAVIOLET (UV) RESISTANT MATERIALS. AT A MINIMUM, EACH SIGN OR DEAL SHALL INDICATE THE; ANTENNA OWNER/ OPERATORS NAME, EMERGENCY 24-HOUR CONTACT NUMBER, UNIQUE IDENTIFIER FOR THE ANTENNA SITE, AND· SCE EQUIPMENT CATALOG NUMBER FOR POLE TOP INSTALLATIONS (WHEN INSTALLING ON SCE POLES). 3. SIGN "A" IS TO BE MADE ON 32 MIL ALUMINUM SHEETING. .'· -y-- 6" NOTICE AT&T operates antennas ot this structure. Above This Point you are entering on area where radio frequency (RF) fields may exceed the FCC Population Exposure Limits. Follow safety guidelines for working in on RF environment. Contact AT&T at 8D0-638-2822 and follow their instructions prior to performing any maintenance or repairs above this point. This is AT&T site USID: 230808 I STONEHOUSE RD892 METAL W/ BAKED ENAMEL FINISH -BLUE -WHITE 4. RF RADIATION SAFETY SIGNS SHALL BE POSTED ONLY WHEN REQUIRED BY RF ENGINEERING OR LOCAL JURISDICTIONAL REQUIREMENTS. RF ENGINEERING SHALL INDICATE THE TYPE AND LOCATION OF RF RADIATION SAFETY SIGNS THAT SHALL BE POSTED WHEN REQUIRED AT A SITE. 'AT&T' SHALL BE NOTIFIED IF A SIGN IS REQUIRED TO BE INSTALLED AT A SITE. 5, RF RADIATION NOTICE SAFETY SIGN SYMBOLS AND COLORING MUST CONFIRM TO THE ANSI STANDARD 2535.3 FOR RADIO FREQUENCY ENERGY AND CURRENT FLOW SYMBOLS. RF NOTICE SIGNAGE STREETLIGHT POLE 8 STEEL BANDING KIT W/ BANNER ARM TYP.TOP & BOTTOM TO COMPLY WITH CITY BANNER POLICY L-16, WINO LOAD 90MPH (FUTURE BY OTHERS) WINDBREAKER BRACKET SYSTEM 9 11" (TYP.) 5 >------(N) LIGHT POLE ARM PIPE: 2.875" O.D.X / 0.203" T -A500, GR. B (6) 1/2" DIA. BOLTS IN 5/8" DOA HOLES 2 3/4" ARM CONNECTION (ISOMETRIC VIEW) 10 4 RAYCAP -PTS 90221 MECHANICAL HOUSING MA TERI AL BREAKER CCESS HOUSING DIMENSIONS (H X W X 0) PTS90221 PO'HDER COATED ALUMINUM THUMB KNOB & LOCKABLE HASP (EXCLUDES HASP& BRACKET) 10.13X6.15X6.000 PTS90223 I 6.15X6.68X6. 285 UNIT WEIGHT/ SHIPPING WT PTS90221 10LBS/12LBS PTS90223 11LBS/13LBS OPERA TING TEMP HUMIDITY -40 C TO 60 C 95~ NON -CONDENSING ELECTRICAL MODEL NUMBER: PTS9022J OPERATING VOLTAGE: 120 VAC MAIN BREAKER RATED : 60 AMP CONDITIONAL SHORT : 10 KAIC DISTRIBUTION BREAKERS : MAX OF (5) UL 489 BREAKERS 0-25 AMP POW'ER INPUT Vt\RE SIZE : #14-/14 AWG CU-AL POW'ER OUTPUT \"1RE SIZE : /114-.f4 AWG CU-AL NEUTRAL & GROUND CONTACTS : #14-/14 AWC CU-AL SPD. DUAL MDV (L-G) OR (L-N) & (N-G) 20 KA 8/20 US NOMINAL EXTERNAL GROUND CONNECTION : 2 HOLE 1/4-20 W/5/8. SPACING UL CERTIFlCATION ; UL67 PANEL BOARDS COMPACT SMALL CELL AC LOAD CENTER FACTORY LOADED WITH A 60 AMP MAIN BREAKER PRELOADED LOAD BREAKERS DEPENDENT ON PICO OR MICRO CONFIGURATIONS UP TO 5 LOAD BREAKER CAPABILITY WITH DUAL SPD LINE SPO STANDARD-DUAL SPO OPTIONAL INTEGRATED EXTERNAL AC/RADIO DISCONNECT IN THE PTS90223 VERSION POLE MOUNTING BRACKET INCLUDED. -6UO \ 1J5-:o ,4 625 I I _,_ · -OU,._\. SPO I 11.tllPE ' EXTERN,4L GRO\.JUOF'O~T \. ·5X. LCAD BRE>\l<ERS MAX I.\AN 8REAKEP I-IST.'1LLED SURGE PROTECTION DEVICE PSU MAX WEIGHT: 11.45 LBS NOT USED (10.8") i-------1 hnrfmrrrrnrrfin/ TOP VIEW SIDE VIEW PSU AC 08 UNIT DETAIL NOTICE FRONT VIEW RF ENERGY EMITTED BY THIS ANTENNA MAY EXCEED THE FCC's EXPOSURE LIMITS FOR THE GENERAL POPULATION. STAY AT LEAST 10 FEET AWAY FROM THE ANTENNA. CALL AT&T AT 800-638-2822, FOR HELP IF YOU NEED ACCESS WITHIN 10 FEET STONEHOUSE RD899 AVAILABLE FROM EXCEL SIGN AND DECAL: http:/ /www.weneedsigns.com/home.php?co1+ 1135 ANO CLICK ON AT&T PH: 510-651-0445 NOl-DC-16 l"X6" NOTICE DECAL 1 Foot Dislonce" VINYL DECAL WITH ADHESIVE BACKING 2 Notice signs must be placed opposite each other on the antenna 1. GENERAL CONTRACTOR TO REVIEW AND ADHERE TO THE APPENDIX OF THE COMPLIANCE DOCUMENTATION FOR EACH SITE OMNI ANTENNA DISCLAIMER LABEL 3 4 5 6 7 GAL TRONICS -GQ2414-06790 PSEUDO OMNI CANISTER ANTENNA MECHANICAL SPECIFICATIONS DIMENSIONS (HEIGHTxDIAMETER): 24.5 x 14. 7 INCHES (622 x 374 mm) WEIGHT EXCL MOUNTING BRACKETS: 30.9 lbs (14 kg) NO. OF CONNECTORS 14 X 4.3-10 DIN FEMALE CONNECTOR TYPE & 14 X 4.3-10 DIN FEMALE FREQUENCY BAND [MHz]: 698-896\ 1695-2180\2305-2360\2496-2690 \3550-3700\5150-5925 4 X 4.3-1 D DIN FEMALE 4 X 4.3-10 DIN FEMALE (698-896) MHz (1695-2180\2305-2360\2496-2690) MHz 4 X 4.3-10 DIN FEMALE 2 X 4.3-10 DIN FEMALE (3550-3700) MHz (5150-5950) MHz MAX WIND SPEED: 150 mph RADOME MATERIAL: ASA BOTTOM • 1"-14 BOLT ':., c-i . 14.7"0 FRONT PART NO. GQ2414-06790-111 (GRAY) PART NO. GQ2414-06790-611 (BROWN) PART NO. GQ2414-06790-B11 (BLACK) PART NO. GQ2414-06790-C11 (CHROME) ANTENNA SPECIFICATIONS RRU QTY. HEIGHT WIDTH DEPTH RRUS-4449 85 81 2 1 17.9" 13.19" 9.44 PSU AC 08 2 12.99" 7.08 2.71" (WEIGHT IS EXCLUDING MOUNTING HARDWARE) SEE MANUFACTURER INSTALLATION REQUIREMENTS WIDTH rl" ·1 1i: <..:> w I ■ FRONT VIEW SIDE VIEW ERICSSON RRU 4449 DETAIL RRU QTY. HEIGHT WIDTH DEPTH RRUS-4415 825 16.5" 13 .4" 5.9" PSU AC 08 12.99" 7.08 2.71" (WEIGHT IS EXCLUDING MOUNTING HARDWARE) SEE MANUFACTURER INSTALLATION REQUIREMENTS I • WIDTH • I I-I <..:> w I ,!. I FRONT 71.0 LBS 11.45 LBS 11.45 LBS ERICSSON RRUS-4415 DETAILS 3 2 APPLICANT: at&t Mobility 1452 EDINGER AVENUE, 3rd FLOOR TUSTIN, CA 92780 ENGINEER: BECHTEL INFRASTRUCTURE AND POWER CORPORATION 16808 ARMSTRONG AVENUE, SUITE 225, IRVINE, CA 92606 (DRAWN BY: CHECKED BY: 0 - .,_ _______ R_E_v_1s_1o_N_s_, ____ ..---t c 0 A REV 05126121 REVISED PER CITY COMMENTS 07115120 ISSUED FOR PERMIT/ CONSTRUCTION 06105120 ISSUED FOR REVIEW DATE DESCRIPTION LICENSER: PROJECT INFORMATION: NWPTB NODE 015A 1991 PORT EDWARD CIR NEWPORT BEACH, CA 92660 BECHTEL DRAWING NUMBER 26134-617-C0-0000-01032-001 SHEET TITLE: EQUIPMENT DETAILS SHEET NUMBER: A-5 SB SAS SRR BY B A PA2021-123 1! 0 NOTES: ALL GROUND CONDUCTORS TO BE #6 THHN/THWN GREEN STRANDED COPPER UNLESS OTHERWISE NOTED OR REQUIRED BY EQUIPMENT MANUFACTURER. 1. GROUND BONDS: ALL BONDS ARE TO BE MADE WITH #6 AWG STRANDED COPPER IN GREEN INSULATION. (ATT-TP-7641 6 7, 6.7) 2. EXTERIOR UNIT BONDS: ALL METALLIC OBJECTS SHALL BE BONDED TO THE GROUND ROD. (ATT-TP-76416 7, 12.6) 3. GROUND ROD: UL LISTED STAINLESS STEEL GROUND ROD WITH MINIMUM DIAMETER OF 5/8" AND MINIMUM LENGTH OF 8 FEET. ALL GROUND RODS MAY BE INSTALLED WITH INSPECTION SLEEVES. GROUND RODS SHALL BE DRIVEN TO A MINIMUM DEPTH OF 30" BELOW GRADE OR 6 INCHES BELOW FROST LINE. (ATT-TP-76416 1.4 / 2.2, 3, 10) 4. CONTRACTOR TO SURROUND COMPLETED CONNECTIONS WITH WEATHERPROOFING TAPE OR EQUAL TO. GROUNDING NOTES T YPE S OF PAVEMENT REPLACEMENT t. TRENCH RESURFACING IN PORn.AND CEMENT CONCRET'E PAIOIENT SHA.LL BE 's$.J7:Z0Gfi°rut:CJI&illlr& ;ff~Tse>;~Jka ~?J ~A~~.'c l+fn-1 EPOXY COA11NG. 2. TRfNCH RESVRFAONG IN ASPIULT CONCRETE PAVfMfNT SHALL Bf PER srANDARO 5PECIF1C.A.110NS srcnCN J06-1.5, EXCEPT THAT: A. ASPHALT CONCRfTf SHALL BE PLACED IN urrs HOT TO EXCEED 4• THICK. 8. APPLY TACK COAT AND ffArHER HEW PA~MENT AS NECESSARY fD SEAL nlE CONTACT JOINT AND fl.JMINATr PA',£11£NT [}[PR[SS10NS 'MT11!N ONE FOOT OF mr CONTACT JOINT. ~ C. COLD PL.AJ,JE £XJS11NG A.C. PA!,£1J£NT {2• MINIMUM DEPTH), EXACr YtfDTH ro B[ DEffRJ,flNED BY TH£ nao [NGfNEER. -H-~ ,;:~ .Jfo~u~%. 5' \\fOf BEO'lffN PAfOI AND N[ARfSf JOINf Pc_S~YT.tt ASPHALT rR£/ICH RES WRA nON CONCRHE mENCH RESTORAnON NOrE: SIREHS/Auns REC£N1l y (L.Asr s ~SJ Sl.URRIEV/RfStJRFACEO/BUU SHAf.L ~OU/Rf EX1EH51'1f PA';fMENT RES~AnON TO BE OETfRJIINEV BY THE f1El.0 ENGNEER. CITY OF Nl<'.WPOlff UEACH TRENCH RESURFACING ""'m • TRENCH RESURFACING 6 6 7 .!1Qlf;_ NfW CONDU/15 AND UNOfRCROONO FACIUTl[S IN 11IE: ROADWAY 9/ALL Bf INSTALJ.£0 ADJACDIT OR CLOSESr AS POSSIBI.£ TO THE DOSnNC £DCC Cf' amrR OR CVRB. IF T11[ PROPOSED CONOOr TRENCH IS Ill A TRAFFIC UN[ ADJ).C!NT ro THE EXISTIHC [DC£ Of CUrTER or CURB, can PLANING ANO PAI/OIENT R£51.JRfACING IMLL 8£ FfEOll/RED FROM TH[ N(ARfST LANE UN[ OF fl/€ PROPOSED rRENW TO THE EXISTING EDGE OF CUTTER OR CURB. IF fH£ TRENQI "MJRK 15 IN A TRN'nC Uffr B£TYrWI TNAmC I.ANH, THE OOVTRACTOO lllll Bf REQ(.JIRED TD COLD PU,#£ AND RESURFM:£ 1H[ [NT1RE m~mc LANE. THE fflEJiCH Cfl:NING SIALL 8[ A ll!Nl/r/1./J,1 Of 2' FROM TH€ tNTIR[ TRNllC LN/£ IN A00.'TION. fF TH£ TRENCH MWK EXTENDS /f,'TO ANY PCRIION CF AN ADJACf.HT fflAfflC f.AJIE OR 15 DAMAGED AS A R[SU/.T OF M CDNTRACTOO'S WOOK OR IS l£SS THAN 5' FRO/J AN EXJSTINC U11llrr TRENCH, mt ~TRACTOR Iv.LI. DC RCOU/RaJ 1'0 COW PW{[ AND RCSURrACC 11/C CN11RC TRA/TIC I.A.NC. COW PI..J.JI[ EXJSn.vc PAID/fNT (2· MIN. OCP111) A.HD R[5'JRFAC[ J()(f,j fLUSII v,rn, [X. S11?[[T PA~T FOR CNTIRC L.AHE ANO RESTRJPf ::-::&111:~:fc~ E_t/fi~f omrn l,4}/f DAJIACCD AND 1RAFF1C LOOP(S) WRING C:005TRUC110N flJLL LANE morn (PARK/NC LANf DR ORM:} 24• IJfN MD1H TRENCH 1'fRU A.C. SCC110N 2' EX. PA'IIEJIENT NDTf: 51RCfTS/ALL[YS RfCEN1l. Y (U.5T 5 YEARS) SI.URRJEl)/RESURFACfiJ/B' .. 71. T SHALL REQUtRE EXTVISl'I[ PAl,fllfNT RESTORATION TO Bf 0[1fRWHfl) BY 1HC nf11J fNGiN[[R CITY OF NlsWPOIU IJ!sACH ROADWAY UTILITY TRENCH DETAIL DRA W.lNG ,~0. ROADWAY TRENCH 5 5 4 FAN KIT ERICSSON RRUS 4415 ---~1r 1 ERICSSON FIBER BOX (BY OTHERS) - DIPLEXERS (IF REQUIRED) ¢ 11 3/4"---- ¢ 17" BOLT CIRCLE 4X ¢ 1.25 THRU, TYP (TOP & BOTTOM)--~ PEDESTAL BASE PLATE DETAILS POLE PEDESTAL DETAILS N01FS: ERICSSON RRUS 4449 ERICSSON PSU ACOB RECTIFIERS (TYP) AC DISTRIBUTION PANEL (BY OTHERS) 3 ,. ANY S!OCWALX R[AIOVALS MUST 8[ RCPLAC[l) IN FULL PANas. IN AODITlGH, r'Jl,WJ~gv 0£:'AL~p:irtr1Mf{:~Nb0ft~ ~ff AN~~ £XP[NS£. 2. SIDEWALK SHALL 8[ RESTORED 'llffH/11 Ci-IE 'MEX Of INSTAll.Alla-1 Of FAaLJTifS. REPLACE SIOEWAlX PER STD-180-L CITY OF NEWPORT BEACH PUBLIC WOIUl'.5 DEP.\RTMU<T AJ'PROVED: Oralfnb. II. GRAGA ll[SS,V 6/2002 PARKWAY UTILITY TRENCH DETAIL DRAWING NO. STD-105-L-D PARKWAY TRENCH 4 3 X X );( * DARK FIBERS TO/FROM HUB 14 PORT OMNI ANTENNA X X X X );( );( * * 4415 RADIO SHOULD BE INSTALLED WITH FAN USE HIGH TEMP SFP (RDH 102 65/25) ON THE CASCADE CABLE BETWEEN THE TWO RADIO USE LONG RANGE SFP (RDH 102 '!J') ON FRONTHAUL-CONNECTED TO 441 5 RADIO WITH FAN 700B/C AND PCS CARRIERS WILL BE ON THE SAME SINGLE CPRI CONNECTION TO THE HUB THE PREFERRED BBU IS 6630 TO COVER MORE NR CONNECTION ON MIXED MODE CONFIGURATION 700B/C AND PCS ARE 4T4R ON A 4 PORT GALTRONICS GQ241406790Q UASI OMNI ANTENNA BIDI IS PREFERRED FRONTHAUL CONNECTION FOR JOBS WITH ONAIR FC>2019 6630 TO BE USED ON NEW HUBS OR HUBS THAT WILL HAVE BIDI CONNECTION BIDI NODES CANNOT BE MIXED WITH UNI NODE ON THE SAME 6630 BBU _.llLJLlL.l __ AC CUT OFF (SPD) AC SOURCE PLUMBING DIAGRAM 1 ;' 1:,._,. --=.c.=,__~~:~:: -------,,·11· ARMORQ!Ss;,, ~ POLYMER CONCRETE ~=~===-=t"=====Jt! ]=. 17" x 30" PULL BOX ASSEMBLY'T -:- BY: ARMORCAST PRODUCTS COMPANY 2" MECHANICAL SPECIFICATIONS {.,.._,.~, DIMENSIONS (WxlxD): 17"x30"x18" [~ APPROX. WEIGHT: 166 lbs. , (BOX & COVER) . ~. LOAD RATING: 10K (COVER) 20K (BOX) ANSI TIER: 8 (COVER) 15/22 (BOX) A FLOATING NUT (2X) 2• TYPE G ,x , LIFT 30.5" PULL BOX SPECIFICATIONS 2 2 APPLICANT: 1452 EDINGER AVENUE, 3rd FLOOR TUSTIN, CA 92780 ENGINEER: BECHTEL INFRASTRUCTURE AND POWER CORPORATION 16808 ARMSTRONG AVENUE, SUITE 225, IRVINE, CA 92606 (DRAWN BY: CHECKED BY: D 1--.... --.... --R_E_v_1s_1o_N_s_, ----..---1 c 0 A REV REVISED PER CITY 05/26/21 COMMENTS 07/15/20 ISSUED FOR PERMIT/ CONSTRUCTION 06/05/20 ISSUED FOR REVIEW DATE DESCRIPTION LICENSER: PROJECT INFORMATION: NWPTB NODE 015A 1991 PORT EDWARD CIR NEWPORT BEACH, CA 92660 BECHTEL DRAWING NUMBER 26134-617-C0-0000-01032-001 SHEET TITLE: EQUIPMENT DETAILS SHEET NUMBER: A-6 SB SAS SRR BY B A PA2021-123 CURB FACE 2' DR MATCH EXIST. Fl VARIES 2' lll' OR 3/8' EXPANSIDN JllINT HATERIAL <TYP) CIJl?B ACCESS RAHP SHALL COHPL Y 'ti/TH CURRENT ADA R£/JUIR£H£NTS llE R=15' FOR LOCAL STRffTS AND 25' FDR ARTERIAL STRffTS UNLESS OTHER'tl/SE SPECIFIED llE llE 10' FOR HA.JOR, 10' FOR PRIHARY, AND 8' FOR SECONDARY STR££TS UNLESS OTH£R'tl/S£ SHO'tlN CDNCRUE SHALL Bf 560-C-3250 CURB RETURN AREA 10' TYPICAL 4' MI,.f llE • 1 ·, I SLOP[ 27. MAX I]• •IW "~ 4' MIN. P.C.C. LANDSCAPE PARKWAY WITH STREET TREES REQUIRED WHEN DISTANCE FRllH CURB TD PRllPERTY LINE EXCffDS 6 FffT IN RESIDENTIAL AREAS. CllNCRETE SIDEWALK IN CllHHERCIAL AREAS 'r/ITH STREET TRffS. 3/8' EXPANSIDN JUINT MATERIAL TYPICAL SECTION 8' 'rl[AKENED PLAN[ JllINTS 1-114' SAWED, QUICK-JllINT llR EQUAL 8' 8' 8' 8' 8' 8' PLANTING llR CllNCRETE 'r/ALK WEAKENED PLANE JOINTS & EXPANSION JOINTS CITY OF NEWPORT BEACH APPROVED: PUBLIC WORKS DEPARTMENT RCE NO. 36106 SIDEWALK DETAIL Drawn: M.Cmcia Date; Sep 1994 DRAWING NO. SIDEWALK DETAIL (FOR REFERENCE ONLY) 8' STD-180-L INSTALL (2) PER BOX 2 ¼" x 4" x 8" COMMON RED BRICK. 5°-0" t.lAX. SECTION A-A EISEL ENTERPRISES NO. 3-½ F PULL BOX OR PRE-APROVEO EQUAL MARKED "STREET LIGHT HIGH VOLTAGE" 1• OR 1}." ti PVC CONDUIT WITH 3 WIRES AS DETAILED, BELOW NOTE: IF 5 DR MORE CONDUITS ITRt.llNA TE IN BOX, USE EISEL ENTERPRISES NO. 5 F, 1¼" -PVC CONDUIT CURB FACE FUSE HOLDER AS PER CNB STD-20~-L TYPICAL PULL BOX REQUJRED AT EACH LIGHT ST AND ARD NOTES: 1. ALL CONDUIT SHALL BE 1¼" DIA. P.V.C., SCHEDULE 40, UNLESS SPECIFIED OTHERWISE, PER PLAN. 2. SEE CNB SID-205-L FOR FUSE HOLDER & WIRING DETAILS. 3. AFTER CONDUCTORS ARE INSTALL, AU. CONDUIT ENDS SHALL BE SEALED WITH DUCT SEAL OR PRE-APPROVED EQUAL. 4, NO CONDUIT RUN SHALL BE GREATER THAN 180' BETWEEN PULL BOXES, 5. PULL BOXES SHALL NOT BE INSTALLED IN DRIVEWAYS, RAMPS OR BETWEEN THE B.C.R. & E.C.R. CITY OF NEWPORT BEACH PUBLIC WORKS DEPARTMENT PULL BOX DETAILS APPROVED: RCH NO. 36106 Drawn: M. Elias Date; Jan. 2004 DRAWING NO. . <D I N PULL BOX DETAILS (FOR REFERENCE ONLY) STREET LIGHT OR BOLLARD PUBLIC WORKS DIRECTOR 1 APPLICANT: 1452 EDINGER AVENUE, 3rd FLOOR TUSTIN, CA 92780 D ENGINEER: " BECHTEL INFRASTRUCTURE AND POWER CORPORATION 16808 ARMSTRONG AVENUE, SUITE 225, IRVINE, CA 92606 l°RAWN BY: : CHECKED BY: 1 0 A REV REVISIONS: 05/26/21 REVISED PER CITY COMMENTS 07/15/20 ISSUED FOR PERMIT/ CONSTRUCTION 06/05/20 ISSUED FOR REVIEW DATE DESCRIPTION LICENSER: PROJECT INFORMATION: NWPTB NODE 015A 1991 PORT EDWARD CIR NEWPORT BEACH, CA 92660 BECHTEL DRAWING NUMBER 26134-617-C0-0000-01032-0Dl SHEET TITLE: ~:) SB SAS SRR BY C B CITY STANDARD DETAILS A SHEET NUMBER: A-7 PA2021-123 CABINET TO INCLUDE: INSIDE PANEL FOR MOUNTING OF: 1. ISOLATION SWITCH 2. FUSEHOLDER--BUSS #BM6032B OR EQUIVALENT TO ACCEPT 13/32-INCH X 1-1/2-INCH FUSE 3. SINGLE-POLE TERMINAL BLOCK FOR NEUTRAL CONDUCTOR TERMINATION 4. ISOLATION SWITCH, FUSE HOLDER, AND NEUTRAL TERMINAL SHALL BE LABELED BY CUSTOMER CABINET REQUIREMENTS: 1. NEMA 3R-HINGE COVER, PADLOCKABLE 2. FUSE SPLICE BOX (FSB) SIZE 12" W X 12" H X 6" D 3. FSB TO BE MOUNTED ON POLE BY WAY OF MOUNTING PLATES SUPPLIED BY CUSTOMER FUSE REQUIREMENTS: 1. CUSTOMER INSTALLS FUSES AND REPLACEMENT, IF NEEDED, ONCE FSB UNLOCKED BY CITY 2. FUSE RATING TO BE APPROVED BY CITY 3. ONE SPARE SET OF FUSES, SUPPLIED BY CUSTOMER, ARE TO BE PLACED INSIDE OF FSB 4. FUSE RATING TO BE LABELED BY CUSTOMER INSIDE OF FSB DOOR PRIOR TO ENERGIZING SERVICE NOTE(S): 1. CUSTOMER TO NOTIFY CITY FOR APPROVAL OF FUSE SPLICE BOX MOUNTING LOCATION PRIOR TO INSTALLATION. 2. CITY PERSONNEL TO NOTIFY IMS GROUP IF FUSES ARE REPLACED. 3. ARMORED GROUND WIRE OR MINIMUM OF 1 /2-INCH RIGID CONDUIT OR WOOD MOLDING OVER GROUND WIRE. 4. GROUND WIRE FROM POLE TO ELECTRODE SHALL BE ENCLOSED IN GALVANIZED RIGID CONDUIT OR EQUIVALENT MECHANICAL PROTECTION. 5. SUBJECT TO LOCAL CODES/ORDINANCES WHERE APPLICABLE. 6. FOR JOINTLY-OWNED POLES, CUSTOMER TO PROVIDE POLE STEPS FOR IDENTIFIED CLIMBING SPACE UP TO CELLULAR ARM LEVEL. CITY TO PROVIDE POLE STEPS AS REQUIRED BEYOND CELLULAR ARM LEVEL. LOWEST LEVEL STEP SHALL NOT BE LESS THAN 7 FEET 6 INCHES. SPACING SHALL NOT EXCEED 36 INCHES. 7. CLIMBING SPACE ON POLE SHALL MEET G.O. 95 REQUIREMENTS. 8. CUSTOMER EQUIPMENT FOR WTR TARIFF IS NOT TO BE INSTALLED ON SCE SWITCH POLE. 9. THIS STANDARD APPLICABLE TO WTR TARIFF ONLY. CUSTOMER CONDUIT TO LOAD AT&T OWNED 17x30" HAND HOLE D 8" MAX EQUIPMENT 15" FSB MOUNTED TO UNISTRUT WITHIN 17x30 HAND HOLE PLAN VIEW 15" 15" I I dl O 6 cu GROUND WIRE TO / / 11 GROUND TERMINAL BLOCK / I 11 WITHIN FUSE SPLICE BOX NOTE: ALL GROUND CONDUCTORS TO BE #6 THHN/THWN GREEN STRANDED COPPER UNLESS OTHERWISE NOTED OR REQUIRED BY EQUIPMENT MANUFACTURER. MECHANICAL CONNECTIONS ARE EXOTHERMIC WELD CONNECTIONS MECHANICAL TYPE CONNECTIONS ■ • TO BE IRREVERSIBLE CRIMP OR EQUIVALENT. GROUNDING BAR i2PIQP1QK51Qrnp!<>) ~~ NEW RRUS-4449 81 2/85 _________ _!:::=;----------!a=~===~ NEW DISCONNECT WITH INTEGRATED SURGE PROTECTION -----------~ NEW RRUS-4415 825-_l_--<-=.....,-", RRUS MOUNTED WITHIN PEDESTAL AT (N) POLE BASE. PSU AC 08 GRADE NEW #6 THHN/THWN GREEN STRANDED GROUND FROM EQUIPMENT TO MAIN GROUND (TYP.) DOUBLE LUG COMPRESSION LONG BARREL CONNECTOR --------~ EXOTHERMIC WELD CONNECTION TO PSU AC 08 TYP (2) #6 GREEN SOLID COPPER INSULATED WIRE NEW GROUND ROD ----------------=....,• NEW 5/8"¢ x 8'-0" STAINLESS STEEL GROUND ROD. GROUND ROD SHOULD BE MIN. 1' BELOW GRADE AND 24"-36" FROM THE POLE. IF A SINGLE GROUND ROD DOES NOT HAVE A RESISTANCE TO GROUND OF 25 OHMS OR LESS, IT SHALL BE SUPPLEMENTED BY AN ADDITIONAL GROUND ROD. SEPARATION BETWEEN GROUND RODS SHOULD BE AT A MIN. DISTANCE OF 6'-------~ LOCATED IN FIBER HANDHOLE HQIE;_ UTILITY DESIGN AND RUNS ARE PRELIMINARY. PENDING FINAL DESIGN FROM UTILITY PROVIDERS NEW DISCONNECT WITH INTEGRATED SURGE PROTECTION NEW RRUS -4415 825 PSU AC TYP ( 3) _ _,____, GRADE NEW #12 AWG THHN/THWN STRANDED COPPER WIRE-_,___.__, RRUS MOUNTED WITHIN PEDESTAL AT (N) POLE BASE. W RRUS-4449 2/85 -il SCH-80; #8 AWG NEW 1" PVC CONDUIT P~ THHN/THWN STRANDED 1r :;-] NEW 17"x30" PULL BOX ---------------L'.: ::'._J FOR POWER WITH WTR/FSB -~-o (FUSED SPLICE BOX) (SCE OWNED) NEW 1" PVC CONDUIT SCH-80 #8 AWG cu r h NEW 17"x30" PULL BOX -------L __J (SCE OWNED) NEW 120V POWER SERVICE TO NEW 17"x3D"PULL BOX (SCE OWNED & OPERATED) ______ __,... t:mIE; 10. CITY CREW TO LOCK FSB WITH #203 LOCK AFTER SERVICE IS ENERGIZED THRU RF /POWER SWITCH TO OPEN CUSTOMER CITY EMERGENCY, RF /POWER SHUT-OFF SWITCH WITH DUAL LOCKING DEVICE TO ALLOW CITY ACCESS. 11 . OPTIONAL LOCATION OF CUSTOMER'S EMERGENCY .,,,,,.-' I 11 r----/ Ir--tx 8' COPPER CLAD STAINLESS l ____ //~ _ ___,!LL!_____ STEEL GROUND ROD t:mIE; 1. CONTRACTOR/AT&T SHALL BE RESPONSIBLE FOR EXISTING CONDUIT, WIRE OR CIRCUIT MODIFICATIONS OR DAMAGE TO "CITY' PROPERTY. 1. CONTRACTOR/AT&T SHALL BE RESPONSIBLE FOR EXISTING CONDUIT, WIRE OR CIRCUIT MODIFICATIONS OR DAMAGE TO "CITY' PROPERTY. RF /POWER DISCONNECT SWITCH, WITH DOUBLE LOCKING DEVICE. 12. CELL CARRIERS SHALL INSTALL A SIGN OR DECAL MADE OF WEATHER, CORROSION AND ULTRAVIOLET (UV) RESISTANT MATERIALS (E.G.,MACHINE-ENGRAVED, LAMINATED-PHENOLIC OR REFLECTIVE SCOTCHLITE MATERIALS) PLACED OUTSIDE THE FUSE BOX DOOR. AT A MINIMUM, THE SIGN OR DECAL SHALL INDICATE THE ANTENNA OWNER/OPERATOR NAME, EMERGENCY 24-HOUR CONTACT NUMBER, AND UNIQUE IDENTIFIER OR NOC NUMBER FOR THE ANTENNA SITE. SIGNAGE SHALL BE PLACED AT 8' -0" MINIMUM TO 11 • -o· MAXIMUM ON THE OUTSIDE OF FUSE BOX DOOR. LABELING SHALL BE PLACED INSIDE THE FUSE BOX IDENTIFYING; RF /POWER DISCONNECT, AND FUSE BLOCK WITH AMPACITY OF FUSE IN USE. 13. INSTALL #8, 3 1 /C TW CU FOR OVERHEAD. REFER TO DUG AP 100. ENERGIZE THRU CLOSED RF /POWER SWITCH TO OPEN CUSTOMER-FUSED SWITCH .. 14. ANTENNA WITH EMERGENCY RF /POWER DISCONNECT SWITCH MAY BE PLACED ON NON SCE POLE WHERE THERE IS VEHICULAR ACCESS TO THE POLE, THE POLE IS A MAXIMUM OF 250 FEET RADIALLY, AND THE POLE/ANTENNA IS CLEARLY VISIBLE WITH NO OBSTRUCTIONS FROM THE WIRELESS TECHNOLOGY RATE (WTR) BOX LOCATION SCE FUSE SPLICE BOX (FSB) CUSTOMER PROVIDED #8 SWITCH TO FUSE HOLER TO GUSTO SWITCH 0 BREAKER N SCE TERMINATION POINT-~~- SCE LINE FEED -----------------~ I r----' I r- 1 ---, I I I I I I I I I -7----- 1 I I D NEUTRAL BLOCK WIRING DIAGRAM -INSIDE FUSE SPLICE BOX FSB WIRING DIAGRAM 6 6 7 -j j CUSTOMER 3" CONDUIT TO U SIDE VIEW LOAD EQUIPMENT BOLT GRND. ~ 2 HOLE LUG ~ PIPE CLAMP 2 BOLT PARALLEL ~ CAST . T SPI ICER CROSS RUN CLAMP UNIVERSAL PIPE CLAMPS ~ 1 SOLT PARALLEL ~ UNIVERSAL PIPE MECHANICAL CONNECTIONS A~ e5 ~ .Il'.E.LSS TYPE TA filLl16 TYPE PH ill:LQl ~ .D'.!:E..__EQ filLfil TYPE GY ~ ~~~ D'.E.LL,J TYPE HA ~ TYPE NX1 rrEE__!'!D ~~~ TYPE XA ~ TYPE CL LUG TYPE RR GROUNDING SCHEMATIC 3 RAYC>I' SPD DISTRIBUTION SCHEDULE 12D/2<IO (2 HDT AND 1 NEUTRAL) FEED FROM A METER WITH DISCONNECT SW. 60 A 2 POLE MCB LINE L1 /LINE L2 BREAKER POS. B R E A K E R 0 E s C R I p T I 0 N AMPERAGE POWER WATTAGE (VA) LINE 1 POWER WATTAGE (VA) LINE 2 BREAKER SIZE# POLE NOTES: 120/240V, 3W, 2 HOT WIRE & 1-NUETRAL ONE-LINE DIAGRAM TOTAL VA 25 AMPS O 120V (L1 & L2) 1500 VA= /120V • 12.5A (L1) 1500 VA= /120V • 12.5 A (L2) 3000 VA= /240V = 12.5 AMPS 1.CONTRACTOR TO VERIFY WITH UTUTY COMPANY THE AVAIi.ABLE INCOMING FAULT CURRENT AT THE METER AND SHAU PROVIDE PER NEC OVER CURRENT PROTECTION AT THE MAIN BREAKER AND SPO BREAl<ERS. 2. (1) POWER SUPPLY (AC-08) FOR RRU-4415 -(4.8A 0120V; 15A/1 POLE) OR (2.4A 0240V-15A/2 POLE) 3. (2) POWER SUPPLY (2-AC-08) FOR RRU-4449 -(9.8A 0120V; 15A/1 POLE ) OR (4.9A @ 240V-15A/2POLE) 4. EXHAUST IS 0.6 A OR 72 VA O 120V OR .3A OR 36VA 0240V EXOTHERMIC CONNECTIONS 5 AC PANEL SCHEDULE 5 4 3 2 2 APPLICANT: 1452 EDINGER AVENUE, 3rd FLOOR TUSTIN, CA 92780 ENGINEER: D BECHTEL INFRASTRUCTURE ,...._ AND POWER CORPORATION 16808 ARMSTRONG AVENUE, SUITE 225, IRVINE, CA 92606 (°RAWN BY: CHECKED BY: REVISIONS: C 1 05/26/21 REVISED PER CITY SB COMMENTS 0 07/15/20 ISSUED FOR PERMIT/ SAS CONSTRUCTION A 06/05/20 ISSUED FOR REVIEW SRR REV DATE DESCRIPTION BY LICENSER: B PROJECT INFORMATION: NWPTB NODE 015A 1991 PORT EDWARD CIR NEWPORT BEACH, CA 92660 I- BECHTEL DRAWING NUMBER 26134-617-C0-0000-01032-001 SHEET TITLE: ELECTRICAL AND A GROUNDING DETAILS SHEET NUMBER: E-1 PA2021-123 ~ .c Cc, o·.::: CG 0 .c u--~ ~_g ~=~ a,= -:a C 0 0" ~~ 0 ,_ ~t-4'. u.; " > • 0 . .,, O 0 0. • ..,.c c~ <("' • .E "" 0 C U.2 , . ~ ;§ ~! -0 .E z .; C: ~ -~ u • . . m .E ~ -i :E "'O.C> ~i~ 0 i: <( ~ -~=· @ 5 ~ ....! ·c i;f " • 0 :;:~ :E 81~ ,_ G'S:' LE®TEK. """" ...... GreenCobra•• Midsize LED Street Light GCM H-Series Specification Data Sheet luminalreData Weicht I0ll•i[46~11 EPA Q,tlf;' Orderinglnfo,mation ~ ... ou CoU-=(>iO G(l.ll•Xn, ........... ~ 7.;'(!Kl• I\'\ , Produo UD "'' Oistl>butlgn Ji f~?<'H'>::><t lll Tr~ll'>'r<t.,.., )II Tl'>OJ\~d,..., ~ Tv;;tl s r~-;-, ~ I Gft\, illxl.vJO.rlo.,...,,., • ......., U,~~~.o<""1blot'W<lv> ..... , 1 ~Q ... C\,re<'1(0.W .. ~'4onor,>a-"'l't=•-·~~,.. .... .,1 ... foct'>l'< ........ "1> ,,iv,1oto-tt,r1tt.,,1N/lelo,~M,,c,<t.,,.,.._,.:ll<A..,.:o,.,,.<~N>f'•!r<11A..,.,..,.,.,_~,,.,111,.,.. o.,,,,,11[f{'()g,,C.U.(II.Of;t...,lCOfl>cltl.OCU>rf·lw):t,Yl,.tl'-~'1'«oldl~<'_.,e,,I J W.,,,')e'f1Jt,1<>~•."-o<!"'"' .. "'( !,;,t<,i.,r,q.,•..:lti'~I"'' .. ~ llol.,......,.~,.\l',l'Ol1V~ 1 """-"M1J1r«-l,..lft•et11u!~o,~"4-<1ut,1,,,d~(M-"'-"-.rl"•-~•10,11!7>·11<1 "fll'•~•.Jl...-.t.-116,,,,.,,.,,,.,c;~, ,,.,~ ...... ,-l>;t:1""' ~ t:.f.r1<<l•N<I-, .,.,,.,,,1/;,uor1J.:,,,...•,itu•od<!J,,..-."Cfr~l,,.,.;1-.• ,., C..-,,;,,wrw,o, ·<A nl.atG .,.,>,.11.,•._,, N<llJ,C,ol<>"4,<lot.o,.r~-<1Jr< .. ;vrt'II Ii !c«>',:t.eUOpOc,,,to<<c.>:ulh~!K><'~•~·ar11,...d-t1 .. , 1 n,,,~,-.•~••H•""'' lodt 1'-'1'-d i,,.,;,i "'-t\,..su,'I •· ,.,~ ....,....,.,.~.._,,_ "''"""'" l J>~~,i,,,,4<tuc._'w:I<! ~J<.it•lJ•~JIIJAliJ....,...~.•c~t:o•;,Ji..rw,..,...,.Jl·1'1 ,-:,,,,,.,.~: .... -odl~ ..... "'"' 9 11.r.h~N;t_,t..,IJ,~l•"r.""""'"f .. U.....:oc,. •--;o,,i~ .. ,ct.t:,,l,o••H'"""'' • flllnt>d<I IO}N{J(C""°'(C.•.Oll.e•J 111:-,,(''fld\'!INl17\l11"14V(~1\>...ro11 ,,, .. ,. ... tu1rtr1tCOd11' ...... '~°'"'""""' l.,.,Pt,e,:ou,n;l';:,I !>.ttt~ltlo! ,._.,,,,J.,~eno:o <Otf'roil'«tll'!Xk' KIIII.CII' C....UOl'llt~I,-tl'C ~..-u~..ci• l.ltJ.CIVW•TU(tl#bel l~\.•~lrk~ ;l:..tu<V.fd,ftG~'d 40ffDffve .WI Cu1,...r,t~~•1 .. m ... "' "' .. ~~:::rn•,..,.il!lo..l ---Co•>Lil'•""-~""\/1 A~~.:_ KUGCM' lbllf:Ml!-~J.IN~On• USGC»' GJI.O. ~S.Or~kl.Sr,>:,\l,•' IUGCM' ,,.,..,,Slo,V,p4_Wj>O,," W " SQ.,..,.i'l;,lo,ti<,tof,t,,l'-'-Tll<«l:d lltl·' lb.tr.<J:>ol,,~::rn~.1.<"'1'""111 '18·· Pu!P1'-,i,ltr(O.il4or•l'L-.,,i., ,.,,,.a,,.1.,1 ~lopl"f-Mnrlo,,IO"UI ,.,..,..s,1™11J•1eo-1 WI W.~i,::,ll!OrU!k-...ltxt.r-! lSIC ll.:~Ot-:,,.1t(Sp,c!-t<\:•I IU'C-' Ull'!vkl-1loo.lH'.«~ SC lwl>l.~~"'l!M,~Q? .,.,.., _ _, .... .-. ... ~,,.,.,,,....,....,., ... .,._., ~~~!>e<f«l><tor,..,~,"'1"1\Cl\."'4111 LE®TEK' Ufl-OffCllOW GreenCobra•• Midsize LED Street Light GCM H•Series Specification Data Sheet I l[OCOde Product uocode Orr>-. Co1~n1Code "' hl) "' " .. Oil-rt s~em Deffvl!!Td cu,~n1Codt w1n,1elWJ lo'T'-<!nl(t.ml1 H'l 5!JO lfleldAd/u~ble. Ovcputit.np I ' lffiaicy fk-ldAdjo,t,b!ti {lm/Wl ~Ranp LE®TEK' lumlnaireSpedfkatlons Howi111 i)ri.ec.,<1.r,__,,, .... 1-ou,.,,..,,1,.,....,,~,.. 1Y>OW1,Lpfo11,:-,r,w.,,i,101l/•·1cr l!-'i/8" v, l·l/i"OO),~Ul'-i'tt• "n! #lM ~ l)lr--:e Jlu'l'llllilm hou1,t1( r.,-O'<ll!n ?.Sl!,e hut1ml.ln1ol't1'el(Ol11'11hJ1o.i.,er1ur/Jni !hit 1~fGc,~_.i,,:1t>otl !o,,i boltm<>u:'1!1'-f: bocUl6.la~Xle /,IQlirt,,-cµo,.,.;o,,,,,.", lGv.1>11t>onper4'<'ilCll(tJ!l010'-l-:,.onul ¥f'k"AI~ Bude• & O....-t>,11\ J.'.o.anHn111:l' ~!"'1.,.!Jnlrr,01,tff.:<1"1\',ti1S'.rrp, ( f<tnOl((ll"l~'"ll-i"tMctl~wi•ho-.rt l.»l1v11to.111~:•e~&1h.OO'l<Ot>dt/Cll'w" l>,).',<-1rbc,utedoor wlh qutl ,.,~•1• LJ1<hh Po1yc.o,00tlnem1•~,.._.·~1UL716Cfo, tlllldoo:U<.ll'-A~J.iot"4!'1.1bl~_.4dffi...WJ (11\Y:;~u,Jconbm,t->n'III•'"'"'""" ··~ GreenCobra'M Midslze LED Street Light GCM H-Series Specification Data Sheet Qu.ahlyConlrol £"i'<"1'1:.,t,-=n1rt,1!)1!<kl,....,~re1n:td~e Mldt'w11~WITl ... !>i'•-W A<Kmt~1 Opl!c-1ISyilem1 J."<CIO·lffilC,:•N~IJl.lt"l•IC,llQ<l(tl(~-.14 T,fN'l Tyt;<'ll).,.1.0,lt(tl'ldmtit-J:1...,_ .,-<J.,_f,j:,w .. ~to>m~ni111PS6r~ L.......,,ti•~o-OO...:~m.1-out~--.-.,1~<){/' (&UG~i-~a.u-oi 0;;,o,.,i1hti-,~!.Ct""",c,ij evu¥toll111'2...,_,r,~,,.....,,'-lbd,:n:i lum11ue1,o,r.1~V.i<'lJc111H(i't~11 •11"0,m1te'1ot'<!moJn~"1l>e'U.ll'llro,,,1~ U'll ~.Jm<~cr1 \I.Utt! "<lei Cu! ,It--"1·1-1\/ Jl'"'O','IJ<'1e..c.ltr,c!l><Joef~c0<>:•olk:t"°.d <-I tul d<' UC iCd-CiUll'II AA 1"'+!~1 a•1 Ned ... ~~Jb'rw.t. llectrial .... t<cvA>t~•~•4~•~!.>·,. foJe-<tl<\~'11 w!-1'1'7,t< -*• cu.,; f'.t"t»'l,..~h IO"~ ~"'"i."UI 11>,u-Sun~1~Jt.n:,11,,.,,.,..,,1ow,1!9.Jtld S(J(Xtho,;r,,.t-1~ <;r.7i•,e,p;-.1~•,ep,:rMll◄ 1111 arl!Ce.nutl'"'Yl~•ASTMC~:$ 1111,m~, '£"be!tMp,priMf8-~•'\l0\6~ fir>.V\ !H1.<.-.ISOOto>.><l.t,lN~=,ef-<!<-"SWGIS-I ,~.d~'N'1\,0.\T~05lli!l<»>•-•W• UW~/ll¥tf"f.'/Ubtb h,,-,11ai•t'I a•• U1 kr.:d ,0. i:!.f: .,.,.r." loc:..t'Orn l'ltt<eUri:!tdSlJmK-dL,ru,J1 Oul,:lL•,:ttl C""'1.)tt-<dll~ Qll.f'~,NP,OdlKI (D1">1~ljf)t( Qrt Int ~tJl>di'11 _1'..,.,.,,->"10.111f>c..110n Ull"'P l<Uttf-.Jt,o,yl(),jrk!.loyAuoc~tcn~i.:;r:: t...,,..,..•••~QUJ"t<lloopt<¥;t!"~''I Ut<>'Qt-'~t,.r,.cf .-rClo~•c. ll(hllmlttlnclMock, AMtJflea!t-tt..u.:.01,.,,,,p01,.,A,.-.100000 PN>tom,1,y H,gh-('1;.1/1-llth,-~...., ti l([I\ l)foduce a "°"'' V-.t-111,0\I:~ PO"~• ;.~lhll '-lu..-.m••e• phisto..-..i•XJ ·~ tfllfd l)y-,:t11+-eo m!,,imum cl ¥.I'. ol 111-1+,1 ,o!fm<l~ Q>~! :r...occ \ \0\/d-~ '"",., ""'P-"<" ..,,,,:,1 ""1~ •~~""•"'t t<'•~"fi .Kl<lraa••c-•.., J«<>ldl,10 houaoflrit'b.li.l'dGnllSIM H\lqo,;!,f <.u-c•d"tCOIW'«IW~ls "°""Wl'llr,· "'llhrtH'9 l'JlciMtr<Cl!:~ln'S l'laun) uo.a,., tt<>·~cl irl K•.md-o<lct..,,lh 1£S ,~,t"'H a n,-.:,.,,,.m ~.-t-r tar.to, cf <Jlj t'ld l\l 80ttitll'jlll'O'"°'-tt> ll!hhl'eC:,,-/NI~~ <)Ch l0•1•H11na"': [),~"'I .,_,(1~1 (MC cllicf IIIT!Oe•Jtu•ecf J()(.;.)f.(\',W), ,s(X)C,( ll'tth.:,t •..:ttd< fer; Cf¥ Pm I!, lt<ll'!t-~I (!OJI.Cf >(O.)'(\C\\Ja~ 10C/tlm,n,.-.ur., t;otl .Kc,lM'l•,cMUtH61o 14 IJ.l~lf ,..,,e_!.,;•~ t£D11<1JOO,.,r11cur3n:f~otdhee inn:t<"->'lcom~w:th~[£,AtlSIC'6!JJ C•lti"'VCl+ih 10,,.-,'11\J.-"WA-"\~tlk( ll•ldAdJu1Ub1lity 101!, lOlVIJ()IA t[Od'M!curreMc.ouM1towet<l,ntlef~ U.l<ld.l<-d1 tum,r,.i'",;omp.41•""" 1oad,.ell'&h\OU1P<,tlorko(1lt111•1t1on,{~ Co1111oh HJ-~W,!!1'1...-clllf~•Cw1.n1ffOC)o, l-w,,,pholocer.l!olftr~l~•!lflO.i!O ANSI Cl.~/,CJJ63.C1Jt,i0.Ctl'>IJ,Cl1t,l~ CJ¾lJ.(l\6J1,Cl½J~.rJ!(..\7.CIJ641 P(i:11-0~-<,1'} l~~•ftJ~rw,u--,C<I' AtlSICll5•t1,..rt,fl'l:R7Jpt-~:ca,,,•!'OI cooe .. 1M;..~f~K1dr~u.:-rtr.! f,i:!;I re1:e;,u;~ ,,.111>~ il,!l('/"c:t«.,nu:ol ~l~fl(il>">~<1',.Wf,o~~\'<-l!to,r,..,...t l«~lllle\n¥,,;od1.-n,.,.,ul; ... ~ OthN rc-r 4/CI~ •t<f.<l'ig&. RI.,\~. II\ \~0 UI l~W ,~rtrn....:~ll~l'Wt..Mr ,.,,1.i,>dju;nt:r't-1',,f'f,<1cfl'\\rol~isp-O'<tlkdt,,,o,~.,, <M>jr~r,lfope:rfllfml"'l'dlt~:,b't' LE®TEK. GreenCobra'" Midsize LED Street Light GCM H-Series Specification Data Sheet """"""""' JOOOKIWW) 4000K(NW) P,oduu SOOOKfCW} 'tf'l'1S 1\pc2R Type JR lED Drive BUG BUG BUG Code cunent Code , it.i!in1 RJtl11r R.atln, ~10 IHJnGl 3!ll0Gl B~uOGJ ,., "" UU0.;.1 IHK'!Gl ll}Ul)G. 6}~:,.• IIJWGl ll~l.(IC.I U LJQUJ eJWG1 111\/0Gl UUOGI BLJllGl UUOGl t.2l:OG2 UUOGl l)UOG2 ·t rve9~<; • T\·~JR Typl'lR ";V!";.4 l~p,! S lEO Orive BUG IUG BUG BUG IUG Code cu,~ Code I Marin& Ra~, Ratlna Aatltll ll.lrin, m UWGI U~G1 BllJDGI S.::JCGi FJUO:'-.:-JUUOG/ 8ll-'lU1 8lWG1 81:,,0Ul ll}IJIJ:.] 11\JOGl UUOG} 8liKIG2 &.·VOG} ll.1U0'.;1 tl.\UOU/ UUDGl PHJOGl ~.•,JOG; l.\tJO(;l UUOGl UU<lGl 111;.iOC,l IIJWC.1 8JtJO•JI IILAHil U;..-0'.il 6'~G1 UUOG: 113.A,U) 5-11.'0Gl HUOGJ U\.10(.;J !-1\.IOGl Tt~2S Type2R T\-0eJR l~pl'4 lt~S UD Driw, IIJG BUG IUG IVG MIG Code Cut~"I Code R~til'II Ritinc llltl"( lbtl"( llltlnt: \)0 111\.IOGI II\UOo::;1 91.iOGJ m ,., IIJlJOGl IU . .IOG? B2U0Jl llltJOGl l!IUOG} 8ll.lOG2 ~L.:OGl 8ltJO<il BJ~G~ uwm !HJOGJ l!-..OC.J 6;uov.• ,,~r} IIJVOGJ 9H-OC.l tl\..,Ct;I 8!UC;1 l1W'i1 jh LUMINIARE SPEC (FOR REFERENCE ONLY) 11 L-------------,------------,--..;;;;;;;;;;====;;;;;;;;;;;:;====~==;;;;:,;_--------,------------,--..J....:..J 6 I 5 I 4 i 3 I 2 I APPLICANT: at&t Mobility 1452 EDINGER AVENUE, 3rd FLOOR TUSTIN, CA 92780 ENGINEER: 8 BECHTEL INFRASTRUCTURE AND POWER CORPORATION 16808 ARMSTRONG AVENUE, SUITE 225, IRVINE, CA 92606 (DRAWN BY: ~HECKED BY: D 1--..------R_E_v_1s_1o_Ns_, ____ _,,--◄ c 0 A REV 05/26/21 REVISED PER CITY COMMENTS 07/15/20 ISSUED FOR PERMIT/ CONSTRUCTION 06/05/20 ISSUED FOR REVIEW DATE DESCRIPTION LICENSER: PROJECT INFORMATION: NWPTB NODE 015A 1991 PORT EDWARD CIR NEWPORT BEACH, CA 92660 BECHTEL DRAWING NUMBER 26134-617-CO-D000-01032-001 SHEET TITLE: SB SAS SRR BY LUMINAIRE SPECIFICATIONS (FOR REFERENCE) SHEET NUMBER: E-2 B A PA2021-123 H G D C B A 6 I 5 4 •. ·-·-·-·· .. 1.. ....•. ·-··· ·-·-··-· 3 ..... -· ·-··-·-·-.. L. -··· ..... ··--······ 2~--···-···--.. _L ___ ·-··-··· .... 1 . ··- 1 l APPROVED 1 ,-APPROVED WITH CHANGES NOTED ' PROPOSAL ORA WING l ; -NOT APPROVED CHANGE AS NOTED & RESUBMIT H 14-PORT · GALTRONICS:~.:,~\ GQ24 I 4-06790 , _ B" ANTENNA (BY OTHERS) i------____ __, 30,_ I .. ·-· TOP OF ANTENNA . ~ '= . .... . J_ 29' I" ANTENN';.'.'~~~:~~t~~~ T 28'-I' --------lec7H 24" /~ CABLE CONCEALMENT_/ ,_ 0/ 36" SHROUD be,~ .•• ·--____ L .... ·, 23'-9" .. · · 21'-6" ···--·------· [ "---f ~! ~~g~ ~tg:g~ ~~H (2) 440X I\ RADIOS ON (2) DUAL SUP BRACKETS I \\ & SPACE FOR (2) TWIN DIPLEXERS \ (BY OTHERS) • ALL REINFORCEMENT 1 . SHALL BE EPOXY • CQAJW _ . ANCHOR RODS] ' SHALL BE EPOXY COATED 0 \ JETTISON SHROUD -la---~ -18 4" BANNER ARM -Ja---~-I0'-4" BANNER ARM ----<hl2.00 0 ······ 3'-IO" TOP OF PEDESTAL 4T4R(I) 4415 + 4T4R (II 4449//MAX POWER•'§ 30AMPS (BY OTHERS) 0 TOP AND BOTTOM :APPROVED BY DATE -------- ,'----24" SQUARE --- PEDESTAL BASE PLATE DETAIL SCALE I: 12 CONCEALFAB POLE# 900794 6 DETAILS (FOR REFERENCE ONLY) I 4 1" 3 G D C 11 I 2 I APPLICANT: at&t Mobility 1452 EDINGER AVENUE, 3rd FLOOR TUSTIN, CA 92780 ENGINEER: D BECHTEL INFRASTRUCTURE _ AND POWER CORPORATION 16808 ARMSTRONG AVENUE, SUITE 225, IRVINE, CA 92606 (DRAWN BY: CHECKED BY: t--.,-.--.---R_E_v_,s_,o_N_s_, ----.----1 c 1 05126121 REVISED PER CITY SB COMMENTS 0 07115/20 ISSUED FOR PERMIT/ SAS CONSTRUCTION A 06/05120 ISSUED FOR REVIEW SRR REV DATE DESCRIPTION BY LICENSER: ~ B PROJECT INFORMATION: NWPTB NODE 015A 1991 PORT EDWARD CIR NEWPORT BEACH, CA 92660 ,-. BECHTEL DRAWING NUMBER 26134-617-C0-0000-01032-001 SHEET TITLE: CONCEALFAB POLE# 900794 _6 DETAILS A (BY OTHERS) SHEET NUMBER: UD-1 1 PA2021-123 GENERAL NOTES· 1. DRAWINGS PROVIDED HERE ARE NOT TO BE SCALED AND ARE INTENDED TO SHOW OUTLINE ONLY. 2. ANY NEW CONCRETE NEEDED FOR THE CONSTRUCTION SHALL HAVE 4500 PSI STRENGTH AT 28 DAYS UNLESS NOTED OTHERWISE ON DRAWINGS. ALL CONCRETE WORK SHALL BE DONE IN ACCORDANCE WITH ACI 318 CODE REQUIREMENTS. 3. ALL STRUCTURAL STEEL WORK SHALL BE DONE IN ACCORDANCE WITH AISC SPECIFICATIONS. 4. ALL STRUCTURE AND MISCELLANEOUS STEEL PROFILE &: MATERIAL SHALL CONFORM TO THE ASTM A53, GRB. 5. HIGH STRENGTH BOLTS SHALL BE USED FOR ALL PRIMARY STRUCTURAL CONNECTIONS, UNO. ALL HIGH STRENGTH BOLT ASSEMBLY COMPONENTS SHALL BE IN ACCORDANCE WITH DIMENSIONAL REQUIREMENTS OF ANSI / ASME 818.26. HIGH STRENGTH BOLT ASSEMBLES SHALL BE FURNISHED AS FOLLOWS: 5. 1 BOLT IN ACCORDANCE WITH ASTM Fl 554. 5.2 WASHER IN ACCORDANCE WITH ASTM F436. 6. WELDING SHALL BE IN ACCORDANCE WITH AWS 01.1 / 01.1 M "STRUCTURAL WELDING". WELD FILLER MATERIAL SHALL HAVE MINIMUM YIELD STRENGTH OF 58 KSI AND MINIMUM TENSILE STRENGTH OF 70 KSI AND SHALL BE COMPATIBLE WITH THE BASE METAL. 7. WELDING SHALL BE ¼" CONTINUOUS FILLET WELD UNLESS NOTED OTHERWISE. B. MATERIAL OR ADMIXTURES SHALL NOT CONTAIN ANY CALCIUM CHLORIDE. 9. ALL ANCHOR RODS, PLATES AND REINFORCEMENT CAGE SHALL BE GALVANIZED AND EPOXY COATED. 10. ANCHOR ROD SHALL BE TIED INTO THE REBAR CAGE AND HELD IN PLACE WITH A RIGID TEMPLATE TO PREVENT MOVEMENT DURING CONCRETE PLACEMENT. 11 . PROVIDE DOUBLE NUTS AND DOUBLE WASHERS FOR STEEL ANCHOR RODS TO ALLOW FOR ADJUSTMENT IN THE BASE PLATE ELEVATION. WRENCH TIGHTEN ALL LEVELLING NUTS AGAINST THE BASE PLATE BEFORE TIGHTENING THE TOP NLITS. 30"0 CAISSON PIER FOOTING CONCRETE FOUNDATION t'c = 4500 PSI 11-3/4"0 I.D. RACEWAY r #7 VERTICAL RE-BARS TYP., TOTAL (6) (4)-1"0 ANCHOR BOLTS r-----BOLT CIRCLE PEDESTAL HOUSE (BY MANUFACTURER) BASE PLATE (BY MANUFACTURER) #3 TIES 6 PLAN VIEW SECTION A-A N.T.S. CONDUIT BACKFILL NOT SHOWN FOR CLARllY. 0 = 17" 5 ' <D ,,., I <D PEDESTAL HOUSE (BY MANUFACTURER)--------------_ '- BASE PLATE (BY MANUFACTURER) \ I ~ PVC - CONDUIT A g in Cl. w 0 '::o 0 _I~ N Cl. N c5 _I ~ z. -~--- 30"0 CAISSON PIER FOOTING NEW CAISSON DETAILS 4 ',, I I I 'i I. I .I '\ 2'-6" ELEVATION VIEW N.T.S. 3 (4)-1"0x48" ANCHOR BOLTS EACH WITH (4) HEAVY HEX NUTS & (4) STD HARDENED WASHERS PER ROD: ASTM F1554 GRADE 55 GALVANIZED BOLTS ON A 17"0 BOLT CIRCLE (BY MANUFACTURER AND LOCATE PER MANUFACTURER"S SPECIFICATIONS) ¼" WASHERS 6" CONCRETE CAP OVER FOOTING (3)-#3 TIES IN TOP 5" A #7 VERTICAL RE-BARS TYP .• TOTAL (6) (2) CLUSTER PLATE (BEARING) #3 TIES AS SHOWN 2 FINISH GRADE (1) 2"11) & /(1) 1"11) -~" (1) 1"0 PVC 7 CONDUIT. TYP. APPLICANT: 1452 EDINGER AVENUE, 3rd FLOOR TUSTIN, CA 92780 ENGINEER: BECHTEL INFRASTRUCTURE AND POWER CORPORATION 16808 ARMSTRONG AVENUE, SUITE 225, IRVINE, CA 92606 l°RAWN BY: CHECKED BY: REVISIONS: 1 05/26/21 REVISED PER CITY SB COMMENTS 0 07/15/20 ISSUED FOR PERMIT/ SAS CONSTRUCTION A 06/05/20 ISSUED FOR REVIEW SRR REV DATE DESCRIPTION BY LICENSER: PROJECT INFORMATION: NWPTB NODE 015A 1991 PORT EDWARD CIR NEWPORT BEACH, CA 92660 BECHTEL DRAWING NUMBER 26134-617-C0-0000-01032-001 SHEET TITLE: FOUNDATION DETAILS SHEET NUMBER: UD-2 D C B L- A PA2021-123 Wl 2-1 W4-1 SHARE THE ROAD W16 -1 C20(BI KE) 6 W20-5(RT) C30( CA)(BK) 0 I 0 0 ~ ., <i J. ~ u ~ 01 u ~ C30(CA) W4-2(RT) _J (l_ N (l_ I OI 0 I a. N (/) ::. (.') t ffi Ul N I-0::: > 0 (l_ KEEP END SIDEWALK CLOSED """'=' I®] ... MUST ROADWORK RIGHT TURN RIGHT CROSS HERE R4-7A R3 -7(RT) R9-3A G20-2 R9 -11A T.A.N.S.A.T NEWPORT HILLS DR E 25 MPH 0::: 0 z OI I=~ ~ Ul (/)N I-0::: 0 (l_ 0 O:'. I W Ul Q. ~~ N I 0 N (.') ;:::- O:'. 0 N u t I 0 N s:: TRAFFIC CONTROL PLAN <(:p >-«: (/) z < ,-.: b I 0 ~ b I 0 ~ R4-7A 65'-o" POLE ID --TAPER -- #3454 T.A.N.S.A.T C30(BIKE) R3-4 C20-(LT) C20-(RT) C27(CA) W4-2(LT) 5 4 LEGEND: rFLAGGER PROJECT f ····==~ FLASH ING L DRIVEWAY eJ slGN ~ SITE ARROWBOARD TOW-AWAY e coNE H BARRICADE@ TRAFFIC T.A.N.S.A.T. NO STOPPING SIGNAL ...• 'i" N I 0 0 N N s:: (.') _J J. t > (l_ •j >-w > zI 0::: ~ <( Ul UN 0 1oo•,0, ~ b I I-0::: 0 (l_ [.> . ... ,, __ ,,9,1/'. '',~-'IJ t NOTES: 1. CONTRACTOR TO NOTIFY RESIDENTS NEAR PROJECT SITE PRIOR TO THE START OF WORK. 2. CONTRACTOR TO PROVIDE ACCESS FOR PEDESTRIANS AT ALL TIMES. FLAGGING REF: 2019 WATCHBOOK -14TH EDITION -PAGE#20 AT THE TIME OF PERMITTING CONSTRUCTION IS TO GIVE A DETAILED WORK SCHEDULE: DAYS OF THE WEEK: MONDAY -FRIDAY HOURS OF WORK: 9:00AM -3:00PM TOTAL DURATION: 21 NON-CONSECCUTIVE WORKING DAYS ANY TIME 1 FULL SCALE 1"=40'-Q" 40 20 0 40 80 FT N HALF SCALE 1 "=80'-o" APPLICANT: at&t Mobility 1452 EDINGER AVENUE, 3rd FLOOR TUSTIN, CA 92780 ENGINEER: -BECHTEL INFRASTRUCTURE AND POWER CORPORATION 16808 ARMSTRONG AVENUE, SUITE 225, IRVINE, CA 92606 (DRAWN BY: CHECKED BY: D REVISIONS: 1--,---,-------r-"'"1 C 1 0 REV 05/24/21 REVISED PER CITY COMMENTS 07/10/20 ISSUED FOR PERMIT DATE DESCRIPTION LICENSER: PROJECT INFORMATION: NWPTB NODE 015A 1991 PORT SUTTON DR NEWPORT BEACH, CA 92660 BECHTEL DRAWING NUMBER 26134-617-C0-0000-01032-001 SHEET TITLE: SAS SP BY TRAFFIC CONTROL PLAN SHEET NUMBER: TCP -1 B A PA2021-123