Loading...
HomeMy WebLinkAboutX2021-0687 - PermitsCity of Newport Beach - Building Division 100 Civic Center Drive, Newport Beach, CA 92660 Permit Counter Phone (949)644-3288 Inspection Requests Phone (949)644-3255 Combination Type - CIP ELEC PLUM Ip11211110101111111111101111111111111 INSPECTOR II COMB Permit : X2021-0687 Project No : 0628-2021 Issued Date : 04/28/2021 Inspection Area : 7 Job Address: Description: Legal Desc.: Owner: Address: Phone: Applicant: Address: Phone: PERMIT EXPIRES 180 DAYS AFTER ISSUANCE OR LAST VALID INSPECTION. PROJECTS MUST BE COMPLETED BY 04/28/2024 OR PERMIT WILL BE INVALID Construction Hours: Monday - Friday 7:00 a.m. to 6:30 p.m. and Saturday from 8:00 a.m. to 6:00 p.m. No work on Sundays or Holidays 1 HOAG DR NB COMM (3) TEMPORARY MODULAR TRAILERS (TRAINING WORKROOM) IRVINE SUB BLK 1 LOT 172 POR OF LOT HOAG MEMORIAL HOSPITAL 1 HOAG NEWPORT BEACH, CA 92663 LIEBKE STEVEN S 1340 REYNOLDS AVE #115 IRVINE CA 92614 949-400-5462 Code Edit : 2019 Type of Construction: Occupancy Group: B Added /New sq.ft. Bldg: 2670 Added /New sq. ft. Garage: 0 No of Stories: 0 No of Units : 0 Bldg Height: Bldg Sprinklers: Flood Zone: 0 X Contractor: Address: Phone: Con State Lic: Lic Expire: Bus Lic: Lic Exp Date: SOUTH COUNTY CONTRACTORS 161 EXETER WAY #87 CORONA, CA 92882 949-205-6304 988175 11/30/2021 BT30048035 07/31/2021 Worker's Compensation Insurance Carrier: WC EXEMPT Policy No: (NO EMPLOYEES) Expire: Building Setbacks Use Zone: Rear I Front: I Left: / Right: / Parking Spaces: 0 Architect: LIEBKE STEVEN S Address: 1340 REYNOLDS AVE #115 IRVINE CA 92614 Phone: 949-400-5462 State Lic:CO28341 Engineer: Address: Phone: Designer: Address: Phone: Special Conditions: Fire Hazard Zone : N State Lic: JOS • •ie• •eo• • ogee • e• • o e Y Cg P 0 4 CC 009OCO • ue00 4 . Y C 4 e Si 0 C • f: .4 0 •4a00 0 C,SJ♦ late O0 O C : Vita(' I" a r.:a Construction Valuation: $60.000.00 Building Permit Fee: $889.00 Plan Check Fee: $773.43 Overtime Plan Ck: $0.00 Investigation Fee: Record Management : Energy Compliance: CA Seismic Safety : Disabled Access : Hazardous Mat Building Green Fee : Moo $32.00 $0.00 $0.00 $91.00 $0.00 $3.00 TOTAL FEE: $2,148.68 Excise Tax: Additional Fee : Grading Bonds Fee: Grading PC Consultant : Grading Permit Fee: Grading PC Fee: WQ Insp. Fee : Electrical %: Mechanical %: Plumbing %: $232.74 $0.00 $80.01 Plan Check Fee : $0.00 Planning Department - $0.00 Plan check Fee : $0.00 Fair Share: $0.00 SJH Trans : $0.00 In -lieu Housing Fee : $0.00 Public Works Department - $0.00 Park Dedication : $0.00 P/W Plan Check: $0.00 San Dist : $0.00 NMUSD Fee: $0.00 $0.00 $0.00 $0.00 $0.00 Fire Department Fire Inspection: Fire Plan Rev Demolition Fee Building Dept Adm General Service Refund Deposit Grading Bond: $1,020.21 Fee Due at Permit Issuance : $0.00 $47.50 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $1,128.47 PROCESSED BY: ZONING APPROVAL: GRADING APPROVAL: PUBLIC WORKS APPROVAL: PLAN CHECK BY: APPROVAL TO ISSUE: Pc OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the reason(s) indicated below by the checkmark(s) I have placed next to the applicable item(s) (Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt from licensure and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do L) all of or L) portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who, through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner -Builder will have the burden of proving that it was not built or improved for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed Contractors to construct the project (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a licensed Contractor pursuant to the Contractors' State License Law). ❑ I am exempt from licensure under the Contractors' State License Law for the following reason: By my signaturepbtty (+acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of the improvements covered by this permit, I cannot legally sell a structure that4 have built as an owner -builder if it has not been constructed in its entirety by licensed contractors. I understand that a copy of the applicable law, Section 7044 of the Business and Psofessrons Coderisavailable upon request when this application is submitted or at the following Web site:http://www.leginfo.ca.gov/calaw.html. Signature of Proper) chwner or Authorized Agent Date LJCgNSJ=D CONTRACTOR'S DECLARATION I tierce/ affirm unller pe palty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 700P 0) of ivis' n 3 of the Business and Professio and effect. License Class • License No Date Contractor Signature WORt4eERS' COJv1l NSATION DECLARATION WARMS': FAILURE,TOSECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE C1JM . OMPENSATIOiI,tAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. I )agrpgy affirm under penalty of perjury one of the following declarations: LA I have and will rnail• rtain a certificate of consent to self -insure for workers' compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the pertorrrlance of the worefor which this permit is issued. Policy No. LJt heft and wflM19il1thin workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Policy Number Expiration Date Nam of Agent Phone # ❑I ce ify that, in the performance of the vy4k�r which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if should become subject tythe wor�j((�g((-s' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. ure of Applicant DECLARATION REG D CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Section 3097, Civil Code). Lender's Name Lender's Address By my signature below, I certify to each of the following: I am the property owner or authorized to act on the property owner's behalf. I have read this application and the information I have provided' c rect. I agree to comply wi h all applicab e city and county ordinance n state laws relating to building construction. I authorize representatives of this city or cou to a er the a entified property for inspection purposes. 1 Signature of Property Owner or Authorized Agent �1 Print Property Owner's or Authorized Agent's Name �tiFE C'aNTEAS Date Date ->i-AA ACTION DATE BY DECLARATION OF COMPLIANCE WITH CODE OF FEDERAL REGULATIONS PART 61 OF TITLE 40 AND AQMD RULE 1403 FOR OFFICE USE ONLY PERMIT EXPIRED ❑ I SUBMITTED ASBESTOS NOTIFICATION TO PERMIT CANCELLED PERMIT EXTENDED PERMIT FINAL CERTIFICATE OF OCCUPANCY ISSUED DEPA QMD OT APPLICABLE TO )( 0 I - OLQB1 RS ACOUSTICS INC 25031 Avenue Stanford, Suite 80 Santa Clarita, CA 91355 P: (661) 251-3965 F: (661) 310-3783 25 May 2021 Barry Paxson c/o Hoag Memorial Hospital Presbyterian One Hoag Drive Newport Beach, CA 92663 Subject: Hoag Memorial Hospital Presbyterian — Modular Trailer Installation HVAC Noise Level Measurement Test Results RSA Project No. 3220521.0330 Dear Barry: In accordance with your request, we have conducted acoustical measurements of the noise levels generated by the air conditioning units serving the three new modular trailers located on the lower campus of the Hoag hospital property. Measurements were conducted to determine if the noise levels generated by the installation of the new trailer air conditioning equipment is in compliance with the applicable noise regulations at the nearby property line to the north of the trailers. Acoustical measurements were conducted on 25 May 2021 between 10:30 and 11:30 a.m. at the property line which is shown on the site plan as being 58' north of the new trailers. The measurement location is approximately the midpoint up the hill between the retainer wall directly behind the trailers, and the Sunset Park Lane service road at the top of the hill. See marked -up site plan showing the modular trailers and air conditioner locations, and location of the position used for our measurements at the property line on the following Figure 1. NOISE STANDARDS AND PROJECT SPECIFIC CRITERIA City of Newport Beach Noise Ordinance 10.26.025 Exterior Noise Standards A. The following noise standards, unless specifically indicated, shall apply to all property with a designated noise zone: Consultants in Architectural Acoustics & Noise Control Barry Paxson c/o Hoag Memorial Hospital Presbyterian Page 2 Allowable Exterior Noise Level (Equivalent Noise Level, Leq) Noise Zone Type of Land Use 7:00 a.m. to 10:00 p.m. 10 p.m. to 7:00 a.m. Single-, two- or multiple -family residential 55 dB(A) 50 dB(A) II Commercial 65 dB(A) 60 dB(A) III Residential portions of mixed -use properties 60 dB(A) 50 dB(A) IV Industrial or manufacturing 70 dB(A) 70 dB(A) If the ambient noise level exceeds the resulting standard, the ambient shall be the standard. Project Specific Noise Level Conditions Noise level requirements for this specific project are different than the noise ordinance stated above and are included in the project documents in the section titled "City of Newport Beach Notes". Note number two in this section states "Sound level shall be field measured at the adjacent property line and shall not exceed 50 dB(A)." This note is included in the site plan on Figure 1. The City of Newport Beach requires that noise measurements be conducted and averaged over a 15 minute period, with a sound level meter set for a slow response averaging time. The result is termed a "15 minute Leq", (Equivalent Noise Level) and is measured and presented in A -weighted decibels levels. By definition, a 15 minute Leq is the A -weighted sound level corresponding to a steady-state sound level containing the same total sound energy as a time -varying signal over the 15 minute period. TEST EQUIPMENT Sound level measurements were conducted utilizing the following equipment which was calibrated prior to and immediately subsequent to the tests: Bruel & Kjaer Type 2250 sound level meter Bruel & Kjaer Type 4189 microphone2250 sound level meter Bruel & Kjaer Type ZC0032 preamplifier Larson Davis Model CAL200 acoustical calibrator Sound measurements were conducted with equipment that exceeds the City of Newport Beach requirement for utilizing sound measuring equipment which meets the American National Standard's Institute 51.4-1971 for Type 2 sound level meters. SITE CONDITIONS AND MEASUREMENTS During our site visit, the primary noise source was vehicular traffic on nearby Pacific Coast Highway. There were no aircraft overflights observed during our site visit. It is our understanding that the trailers and potentially the air conditioners would only be used during the daytime hours and not used during the nighttime hours, therefore, ambient noise levels were measured in the daytime during off-peak traffic hours when the noise levels from Pacific Coast Highway would be the lowest. Barry Paxson c/o Hoag Memorial Hospital Presbyterian Page 3 —� _ __ _� t ' WORK AREA RETAINING WALL -- . - weR UNE 'IAGOUSTIOAL MEASUREMENT POSITION 3-24tx40' MODULAR TRAILERS if .Olseas.w....-..aerie i — -"t LOCATION KF ate rt+- I OF EM +g . g= . •. e 1-t4TOLINIME7 At, UN Ti P. PATH , AO =' MODULAR I'A ;4 I i G, : - 2 \.%, :>, . -" 4, s__I Pyl. ... __ ' _ ....I L_.... w 1I 1, e w. _ rrawERtnTtc �. PACIFIC COAST HIGHWAY CITY OF NEWPORT BEACH NOTES — T TRAILERS ARE CONSTRUCTION PE VS AND ARE 3 THERE 15 NO NET LOSS IN THE NUMBER OF LOWER CAMPUS SURFACE PARKING SPACE NOT£MLIILEHEO ALL. 'POLEAX. WILL RECONSIDERED FNMA, nfl Dip Nom(: OA TEPP AN VIRVFY OG FYt4TWR DARKINA COWLS RFC,,A FF ONE SINGLE TOTE VB SUILDING THE TOTAL AREA Of SPACES :PAVING 34 SPARE PARKING SPACES. OUR TEMPORARY MODULAR TRAILERS WI ALL THREE TRAILERS PARKING 1 ET.670 SO FT_}:S MUCH LESS THAN SPACES PLUS PARKING SPACE THAT IS USED AS AM: PARKINGACCESS 20EE THAT ALLOWED FOR A: SINGLE.NONSPRINKLERED I Yet IS USED FOR TURNAROUND SPACE TO ACCOMMODATE ONE WAY CIRCULADON: THIS PEE VS SUILDNO j9000 SO FT:?: AS A RESULT, THERE WILL NUMBER OF SPARE PARKING SPACES FROM 3910 I4 SPACES STILL RESULTING IN NONE NOT BE ANY. FIRE RATED WALLS OR FIRE SEPARATION PARKING SPACES DISTANCES REO URED BETWEENEACH TRAILER UNIT. 4. THE MODULAR TRAILERS ARE TEMPORARY STRUCTURES TO ACCOMMODATE HOAG ST REMODEL OF THE CANCER CENTER. AS TEMPORARY STRUCTURES THEY ARE INTENDED 2 SOUND LEVEL SHALL BE FIELD MEASURED AT THE TERM. A4PSTRUCTURE ERECTED FOR MORE THANE MONTHS IS REQUIRED TO SE ARCH ADJACENT PROPERTY LINE AND SHALL NOT EXCEED CONCRETE FOOTINGS IN ACCORDANCE WTH CSC CHANTER te, OUR UNITS WILL BE ANC DOA TEMPORARY PAWNER FOUNDATION SYSTEM. IT IS OUR UNDERETA NINC CITY WU APP EXTENSION TO PROVIDE. ADDITIONAL 6 MONTHS _ - _. , .. Figure 1 HOAG MEMORIAL HOSPITAL MODULAR TRAILER SITE PLAN & ACOUSTICAL MEASUREMENT LOCATIONS Barry Paxson c/o Hoag Memorial Hospital Presbyterian Page 4 The ambient noise levels at the property line with the trailer air conditioners off between the mid- morning hours of 10:45 and 11:00 am, was found to be Leg - 58.8 dB(A). These ambient noise levels already exceed the 50 dB(A) criteria of the requirements included in the site plan notes. Immediately following this test, the trailer air conditioners were turned on and verified to be generating cold air by the undersigned. Measurements were then conducted again at the property line with all four (4) trailer air conditioners operating. Noise levels for the 15 minute measurement period were found to be Leg - 58.6 dB(A). The air conditioners were inaudible at the property line closest to the trailers. The lower ambient levels measured with the air conditioners on, was due to a minor 0.2 dB(A) variance in the traffic noise. SITE CONDITIONS AND MEASUREMENTS Rounding the measured noise levels of the ambient conditions and noise level conditions with the air conditioners operating to whole integers, the measured levels are the same Leq - 59 dB(A) for both tests. Mathematically, for there to be no increase in levels when the air conditioners are operated, the contribution of the air conditioners must be at least 10 dB(A) lower than the ambient measured conditions or no higher than 49 dB(A). On site, noise at the property line from air conditioning operation was found to be inaudible. By calculation, we determined that the noise contribution of the air conditioners could not be greater than 49 dB(A) which satisfy both the City of Newport Beach Noise Ordinance and the specific requirements noted in the project drawings. This concludes our report. Please feel free to call with any questions or comments regarding our report or measurements. Sincerely yours, RS Acoustics Inc. Robert Schmidt, Principal C:\users\T3810\OneDrive - rsacoustics.com\Projects_current\Healthcare \Hoag Modular HVAC at PL20210525 Hoag Modular Trailer HVAC.docx