Loading...
HomeMy WebLinkAboutF9800127 - MiscORANGE COUNTY HEALTH CARE AGENCY ENVIRONMENTAL HEALTH DIVISION HEALTH SERVICEORDER 149484 Date Client Name Address 8 Paid By • Initials Ph# Adrlica,l ....�.. C�_o. i%�/emu'.. Ph# Please circle the respective service code(s) 01 CEQ/HSF (Acct/Bat# ) $ 02 CEQ Plan Check/Foods (PC# ! ) $ 03 'GEQ Plan Check/Pools.(PC# ) $ 04 Food Vehicles Cat $ Decal No(s) 05 CEQ/Court Restitution/Judgement $ Name Case# 06 Hotels/Motels (Acct/Bat# ) $ 07 Massage Parlor (Acct/Bat# ) $ 08 Noise $ 09 Liquid Waste Hauler $ 10 Farm Labor Camp Registration $ 11 Land Use $ 12 Hazardous Waste (Acct/Bat# ) $ 13 Hazardous Waste Fines. $ 14 Hazardous Waste .Restitution -/Judgement. Name Case# 15 Hazardous Waste Clean-up $ 16 Infectious Waste (Acct/Bat# ) $ 17 UST/HSF (Acct/Bat# ) $ a) UST Plan Check (PC#Yam i33 1 $ 19 UST State Surcharge $ 20 UST Restitution/Judgement $ Name • Case# 21 Wells (Const _ Recon Destr ) $ :Water Cath_ Init Monit. ) • Add. Monit #Wells Driller Consultant 22 Backflow/Cross Connection $ Client(s) 23 Small Water Systems $ 24 Copies of Records $ 25 Tax (Refer to Cost of Copies) $. OTHER PAID BY CHECK NO. l O It-IC�1 F272-9.1539 0 WHETE: CIIMM% Copy YELLOW: Accounting Copy MANILA Cashier's Copy 04/17/1998 10:48 7147605577 PAGE 02 ek G mare( /2dG g��; /b ✓5eccv +:ri $2frl (vo UL l0 '3`" * 4 O(ocied l v use a s 5eeonda r j� ig/ . — ,-bon steel p/Pi49 iy approved {ov Ir/ma✓- PPR-17-1998 09:27 PACIFIC MECHAV:CAL i12A1t'. /v4� K 15 110 f a artWeL apprmoal' // / trt 14, ;ye a1�i11l�hll�l Dualo 3000/L Product Oaf a Dualoy 3000/L Fiberglass Pipe and Fittings underground piping for petro urn, products, alcohols, alcohol -gasoline mixtures and reforrnulated fulls uses and applications Service station product, vent and wowskessfyapmg auk MIN weenies sold fusiiag ermlrU exports. marinas *net marts Sr/Nean Central fuel ea systems All fiWng systems requiem ULo►ULC !tryfof 000011.4i products, alcohols, aloohSFpsseline testae andivlomarslfuele .. E Performance ; Dwaine pressures toXepse . .. cesenuora apflbn ttmp anrrea to 15011 pfi'c Listings NfUrwtitet. Lebontsdes Its Composition 0ualay3000rbisgasps in bw united 6taNa with Unde varba4 Labaat itfor renne Ufe u+dergrouaeplpingkirpr.isum prayed smaneedeohet blends. alcohols mates msmvol and ethanol, irr0 ,fSm1eied*als(pba henn J: Oar WOOL pipe and fittings we sendMamaWlhundrwraera•ttoteeearCarl a" leCMH7;g).indV NetnerlandswentWWApid.ATAno. 2062i14,and w4htfaOren MiNteyatins Envlranmwint Anarbit261 bi>;. In Greet Brain the Maley 90004.svatern alas teen taaad end e.deptedthflh.t,ofub.Redd genera Authatti. Sipe — Fitamenwwound fibergW6 ralnforded epoxy pipe with integrel epoxy liner and exterior OWN. Whin dessltad in accordance wigs ASTM 012310 end ASTM 02996. the pipe ma me toeowing Cie Si 11CF1-'4,30. RRetge — Compression-mddsd and et.mem-wound tbergep reintorCed epoxy Adhesive —A20L7 ambierttcure, two-part epergr to datvleas deluding eloehou) Joining *atom mill end spiyoe teperAep•r edhwivrbdnded Joint Pipe lengths standard tom random length. (17 to 21 f0 Other lengths weasel* en taunt Fittings t9 39od Adapters: Deli x MDT female, Rage rings' Adapters: OM a NAr male Range stubsind■' Adapters: isolation% Nipper •• Adapters: spigot it Naar female' Reduce bushings' Adapting opigotxHST male Repaircaudlitgs' 4Y Elbows' tgave 90• Waal Tea' mane atn End cape' 11 insianas mods rant. Owseam myna raaY e * era melts amp sot We%drsasd a Wag Sinal* IMPS tet fassi tasd r meta wendrrtnr aMw.n airs da.i .taus a is ice rims rrawwwn e.uee err. • Nellawaeemue•.eine+Rlas atnnnre...1wrises sr ter ironware • owe ens wetrisr. warewui. awn Nb rmownw FP265E (6J92) 04/17/1998 10:48 7147605577 PPR-17-1998 09:20 ens waagnSS PAGE 03 PACIFIC MECHPNiCAL P.03 . �Iw vw yr .v.w .rrrwy.r •Mn• '.ge.y,q (h) t}nm) jog hf _r1 6N Pb�tl 2 50 2.37 2.21 01250 0.0/0 0.20. OA7 3 80 3.45 3.32 0.085 0.095 0.46 0,2 100 4.51 al 0.087 0070 0/7 1.00 8 150 0.33 0.30 0.120 0.100 1%37 2.10 1) Nos sums sewn ens some ens sip en aAal, Aa1N arse Q w eeaghM Mr draw wMN OmOa4na 1 pIoal PIPe pe on'nance Nominal Premium Pi SRating 6MIize On° (Oslo) 2 50 000 3 80 200 4 100 1T5 6 150 1TS 2000 TI Al Wit er'C aminvaae rwb. Or net Am i Mt eras vita. ummaa ' mamas) int rn: P4easus' 3200 103 2400 90 2000 30 38' Fittings Prsssu►t PArtot7nanoe 2 POI simnel) M Menge, Consult Mlaron,publication ,OpmeaY 8000/1.Prmt a Onsww . s. F72/6. Prows ratings of Stings Wltmut UL Owing aro walkbla o11 most Petroleum Pneduta.a Orgy Efiel Pipe Size Elbows (TTen Ads Hss CO more Ftp.' 9ud !educe p 2l 50 300001 �!8 200 3 (� 3 SO 200 200 200 200 i 200 200 200 4 100 1S0 150 160 160 ! 150 150 150 a 150 175 175. 176 17'! ! 175 175 175 Petroleum Products. Aleellola end wawa Nominal Plpa Siam Duna Snl ("+"'1 (qq) 2 50 1TS 3 80 125 4 100 100 8 150 100' 1) bl titsiedne CP Ten I X MA All Other Alum SSCIPM (On On Air 176 176 300 SOO 125 125 200 i 200 100 100 150 i 100 100' 100' 17J • 173 Reducer 64p11i1fS 300 200 150 175 End tain emmi 175 125' 1W 100' LO 3010.4 NOTR1se t 04/17/1998 10:48 7147605577 APR-17-1990 09:28 PACIFIC PECHAW CAL PAGE '04 P.04 Tensile strange IAag2lAUU Circafasnaal Tetlslle Modulus tosaltudlot Clmu n+.dal CompiMan nied{/us Longsudlnal Long•tann hydroataeo assign teals Poisson's rsV& vp 103NI De p51 10s pN 1os pal wow 10301 25.0; 70.0: 1.0 4.2 36.0 3.0 0.16 0.26 o21os 161 01608 1a1 02106 1e1 142 142 11 SINS SA MSS INS *lira m Ma lraeeelst 31 TM b*aSn /teNMlies SSW MSMIewM ww.owe wwwm.wS— e.r.e.lrslfwens. featalgoevinivi Nominal Pip. Slot SOrhlws Ss' pn) (mtj 2 50 3 60 4 100 6 150 1) tax 5%d■aaiea, Betiding radius Ea 2901.4 Naminul Pipe ea M)'MRU 2 60 3 80 4 100 6 160 Minimum 76 100 160. 200 Maximum Osllsetlon per204tJoint 6540 16 10 7.5. MlNmunl langeh R dultsd rot 10• aw1ge li0 is 20 27 40 1) al. 0yIIMR Saw r Seta ..wlM. M'M.MwnbSMn► So nel eA �Olueti pleSsllw N0lettl e ►e99GLL6 St:It alit//1/pP 04/17/1998 10:48 7147605577 APR-1'?-1998 09;29 PACIFIC MECHANICAL 1MP$aiO'Pa..'145�ts1QJkq/a7it 1 GPa • 1011 thi 149000 pai Is 10,200 key* 1 in =25.4 mm 1 ft &Mon 11b4ns0113N'fli • at (e, -32) PAGE •05 P. Important MUM! This thrifty* and die inn:smitten and racornmsnastans ktantalns sratbsi on In risleriely begsano tos act* moitstuer. ouch factors Ws sartaters Is invitormsn, spplicatIca or 'natation. changes In wag procedurso. or estripolsOon of as msy cause dearantrasurts. Ammon aeons nmawantlan or womanly. span or invalid. Including warrentiss efnwv iwdaSlty&Tams his pupas*, a to ths accuracy. admisuacy or cchaistract of the Mcomtrendations or Informition ccritairied her. flow mama no gaily vatatsosucjr correctIon with this Maratury wits isformation or recammendagons oorMasts Ammo. - .4•11118solnpsOkiliskis ShmelSsoliSpe adios alinnallal. , Plit010, Oat Mina j#JWINa:::WM MIY&Tacesings2 hicisONT0M0700 4191 M2 Gam 2210 PfrigIn3HMIO-TTIS Thnisholte Picl1.1301 filiPt3)119/2142 PhothraWitt-T3341 Tet3INDSMOIONAS • Tee 41:125710.09 114. PulS1-1102 Fax 0$43645254 Ovisaddiera Tee lionten, lisaiCassisOssamissin sessiessrial 10•81sisiii”biefeunelebeeir atinuidowinallit • OMILimederamwymmageppoweirOUSONIM TOTALAP.05 PAN -PACIFIC PLUNIDING & MECHANICAL 1821 McGaw Avenue • ,Irvine, CA 92614 • (714) 474-9170 • Fax: (714) 474-4274 , HOAG HOSPITAL CENTRAL PLANT iH4l".rf011 /esl IS !f',qdtAti'G 001 I 'j •. 1t. rr'r M) I 'J'. LI'I :Jb;291(0; SPECIFICATION SECTION 15483 FUEL OIL APRIL 8, 1998 NOTiCE ORAJUfi,,:; �'�fl�I�I.i_,FAL.bi C R AGC NCY CTIC ^^11 y It f3(i I!IStir: (T,r ct&mot r,;.1 'tanks it fi nnd riot be r`•O tIi E.C4 o, ,must Ibe HOAG HOSPITAL CENTRAL PLANT SPEC. SECT. DESCRIPTION 15483 FUEL OIL FUEL OIL. PIPING ABOVE GROUND BELOW GROUND FUEL RECIRCULATOR STORAGE TANK FIL-SPIL CONTAINMENT BOX SUMP ACCESS BOXES FLOAT VALVE EXTRACTOR BALL FLOAT FUEL OIL LEAK DETECTION PACKAGED PUMP SET FOOT VALVE EXTRACTOR ABOVEGROUND SPILL CONTAINER Pr le is fgerill ABOVE GROUND 0t}Uft 0n1. el up Double Contained Piping Systems. by Ch@mtrol® cn U N N Systems options SYSTEM AVAILABLE SIZES JOINING METHOD FITTING AVAILABILITY Carbon Steel' '.PVC,Sch 80 y�7 v 1att irr .n TYPICAL APPLICATIONS /3th u -' Epos Ceement 18/24%hs�? 1/ /2,thru �18' 24 a GA.W/ Solvent`. 50 : E a �Evres`f i fia'tE ' tot)te M D ' 4B 1- rtt "12 :f 3uc , rgTr Crb7-" u 7A• � rh'�frYr,, . 99925 T B1 ;BCV E i • 4 '`v W^ �,Orgamdchegtrcals,rpetrofeum-, Tt�1DZG;/4B, d �/oducfs,' and mdd adds and b 1/8B' ST1P; ombo ` Y$ O/ganrc:chem{cals "etroleum products,; some cor olives and rnnrentrritori nnr/s h, , :k3As . `' ,FZIL Pri, v�.,3 HAre-t)Ffy���i"��-:'t 0✓ . ..`+:..*. L js, •;fay „+R,WS:*S4`'.''.2tT .::xsa s�. b' Le'�. rci , i `"i"' . `,, Carbon Steel I CS FRP a ;,, •. ; ......a^'. 5', v.:t' �'ir ,lrf �. +/2/2 thru ,'18/24 ��.. ��*, "s n � '{t -... ''k G.A".W /r- 4- ;' Solvent ofl.z Cementing :. , •J45, ' -�fe y� Y ., y1. 9BCV TM DBZ s - '4° > z.•,- rh { Y 4h� ,.4 P oductsc ernsc. aclorrostrol a d concentrated acids '' � COPPER/PVC COPPER/FRP + !2 thru 6/10 ' Solder/ Cement Epoxy 90, 45, T R BV, BCV, TM D Z Organic chemicals, petroleum products, some corrosives and m!I" . Stainless Steel"/ FRP 1/2/2 thru 18/24 G.A.W., G.T.A.W., G./W A M... Solvent Cementing 90, 45, T,R,BV,BCV, TM, D, Z Organic chemicals, petroleum rn - products, and mild acids and bases f: ; i s NOTE: 'Avail. in a wide range of schedules. •'Avail. in 304, 304L, 316, 316L, and a wide range of other gradesand schedules. "•Avail. in Schedule 40 and 80. Expanion loops available for all materials. FITTING CODE INDEX Pressure Fittings: DMV Fittings: 90=90° elbow • 45=450 elbow • T=Tee • R=Reducer BV= Ball valve • BCV= Ball check valve •TM=Termination D= Discs • Z=Zone anchor C=Cleanout • FD= Floor drain • 1/4B= 1/4 Bend 1/8B=1/8 Bend•1/16B= 1/16 Bend•ST=Sanitary tee P= P-Trap • W= Wye • Combo= Wye and 1/8 Bend 4 GUARDIAN DOUBLE CONTAINED PIPING SYSTEMS 1.1 INTRODUCTION AND OVERVIEW Concerns over chemical Teaks and spills have been mounting overthe past several years. A number of. social, legal and safety issues confront industry today. Pollution of soil and subsoil due to spills and leaks eventually leads to groundwater contamination. Every day we read stories about soil and water contamination and the huge pollution problem facing our nation. On November 8, 1984, President Reagan signed into law the Hazardous and Solid Waste Amendments This law requires the individual states to either accept the federal law as written or developtheir own more stringent standards. To date, the majority of states have developed their own final. regulations. The regulations requiring the use of double containment technologies are as follows: • Petroleum Pumping and Tanks mandated by RCRA written as federal law 40 CFR 280. • Hazardous Substance Piping and Tanks mandated by RCRA Subtitle 1, written as federal law 40 CFR 280. Tanks and piping that are included under the RCRA regulations, also referred to as the UST regulations, include: • All containing regulated substances as defined in the above mentioned regulations. • Systems where 10% or more of their total volume are below the ground surface. • Tankless piping systems where 10% or more of their volume is below the ground surfaces. The risks from leaking UST's and related piping include health, safety, .fire, explosion, contamination, clean-up cost and liability, just to name a few. The EPA findings are over 3,000,000 existing systems in the U.S.A. Presently 100,000 UST's are leaking, and it is estimated that 350,000 UST's will be leaking by the year 2000. EPA findings also indicate two-thirds of the Teaks will be caused from pipe failures. Unfortunately most leaks are detected only after major soil contamination has occurred. The EPA has also done clean-up estimates that range from $35,000 to over $1,000,000.. It is important to note that these estimates include excavation, soil testing, groundwater clean-up and total replacement of UST system. Guardian Double Containment Piping. Systems have been specifically designed as complete package to meet these requirements. Whether the service is drainage or pressure, above ground or below, Guardian builds a system to meet the requirements. With a wide selection of materials to choose from, including steel, stainless steel, PVC, CPVC, fiberglass,. PP, PE and PVDF, there is a system to meet your specific requirements. Unique assemble and testing techniques allow unsplit components ready for installation.', Potential Teaks are eliminated by using standard joining techniques used in the piping industry. The easier a system is to install, the greater the chance of success. Complete contractor trainingis available by factory experts to insure installation integrity. Interest in double containment piping will continue to grow far into the future. Guardian will continue to manufacture systems designed to exceed the service conditions while remaining as simple to install as. possible. ABOVE GROUND CARBON STEEL \ CARBON STEEL r 002 OD1 IT Ar oUM$Olw. •e .Re cp¢r.MRY RPRCANO OUR PRODUCTS: AS A RESULT, Al. OIMEIYSIORS ME su6.2cr TO Clara IMTRa,r Nemec DRAWN BY: EF DATE: 9/21/95 REV GATE: 10/11/95 CK'D BY: FM CK D BY: DT GUARDIAN DOUBLE CONTAINED DI0808P1 PIPING SYSTEMS PIPE L2 L1 OENTRA—GUIDE SUPPORT • INTERSTITIAL ZONE DIMENSIONS CARRIER/ CONTAINMENT L7 L2 ODI 0132 1/2 X 2 20' 5' .84 2.38 3/4 X 3 20' 5' 1.05 3.50 1 X 3 20' S' 1.32 3.50 1 1/2 X 4 20' 5' 1.90 4.50 2 X 4 20' 5' 2.38 4.50 3 X 6 20' 5' 3,50 6.62 4 X 8 20' 5 4,50 8.62 6 X 10 20' 5' 6,62 10.75 8 X 12 20' 5' 6.62 12.75 GENERAL NOTES: CARRIER .' ALL ENDS ARE BEVEL FOR WELD CONTAINMENT — ALL ENDS ARC PLAIN END PIPE 15 SHIPPEO BUNDLED AND ENOS ARE REINFORCED AND WRAPPED TO PREVENT DAMAGE ALL DIMENSIONS ARE IN INCHS UNLESS OTHERWISE INDICATED DOUBLE RANDOM LENGHT P.O.A. ABOVE PIPE MEETS ASTM SPECIFICATIONS: CARBON STEEL PIPE A53B & AI OS SCHEDULE 10\2fi\40\80 PIPE \ FITTING SUPPORT DIMENSIONS DRAWN BY: K.G. DATE; 5/23/95 REV - OATE: 11/21 /95 CK'O BY: CK'D 6Y: DT GUARDIAN DOUBLE CONTAINED PIPING SYSTEMS DI0004CG CENTRA-GUIDETM t WING LENGTH NOTE #1 GENERAL NOTES: 1. LENGTH IS SIZED TO FIT BORE OF CONTAINMENT PIPE. 2. I.D. SIZED TO PROVIDE NON -SLIP AGAINST CARRIER PIPE CLIP IS APPROX. 2" WIDE SIZE SSI EY *LD' LENGTH PART 1 1 /2" .19 .83 1.75 728007 I 3/4" .19 1.04 1.75 728008 1" .25 ' 1.30 - 1.25 728009 1 1/2" .25 1.89 1.10 728011 : 2" .25 2.36 2.13 728012 ` 3" .38 3.49 1.50 728014 4" .38 4.49 1.75 728016 i 6" .50 6.61 1.75 728018 8" .50 8.61 1.75 728019 ; 10" .75 10.70 2.00 728020 _awmuK `E ARE Eamumr • rcau. ALL Witt3CIO '/E A 1E p*.6E M icvr GENERAL NOTES: ALL DIMENSIONS ME IN INCHES UNLESS OTHERWISE INDICATED MOLDED POLYPRO '',;,• 7ABOVE CENTRAyGUISE' MEETS ASTM:,SPECS: BLACK `pOIYPRq= p41`0 ."• CARBON STEEL \ CARBON STEEL RCrc AT cynAOLAN. WI ME CONstualy WANK Ol•R Pf1COVc15t A4 A DRAWN BY:.EF DATE: 9\21\95 REV DATE: 10/11/95 CK'D 8Y: FM CX'D BY: DT': 90 DEGREE ELBOW DIMENSIONS GUARDIAN DOUBLE CONTAINED PIPING SYSTEMS CARRIER/ CONTAINMENT Al Aq 001 002 1/2 X Z 5,00 4.00 .84 2.38 3/4 X 3 7.00 6.00 1.05 3.50 1 X 3 7.00 6,00 1.32 3,50 1 1/2 X 4 7.50 6.50 1.90 4.50 2 X 4 7.80 6.80 2.38 4.50 3 X 6 10,75 4.75 3,50 6.63 4 X 8 15.00 14.00 4.50 8,63 6 X 10 17,63 16.63 6.6310.75 8 X 12 19.00 18.00 8.6312.75 DIO80890 GENERAL NOTES: CARRIER - 3OW - 6 THROUGH X 10 THROUGH 413 X 12SUSE SHORT E LONG DIRADIUS 90US 90 GDEGREE LBWELOELBOW ALL ENDS ARE BEVEL FOR WELD CONTAINMENT - 1/2 X 2 THROUGH 8 X 12 USE MITERED PIPE ALL ENDS ARE PLAIN END ALL FITTINGS ARE FACTORY TESTED ALL DIMENSIONS ARE IN INCHES UNLESS OTHERWISE INDICATED ABOVE FITTING MEETS'' AVM SPECIFICATIONS: CARBON STEEL PIPE - A538. & A106 SCHEDULE i10\20\40\80 C^.F nm FIT. ;iG - A274 11 win A CUMOWI: '.E ARE CO.STMR1 imeROW1G 040 Meet/CIS. AS A - _ . -i C..•- Auc CARBON STEEL \ CARBON STEEL DRAWN BY: EF DATE: 9/21 /95 CK'D BY:. FM REV DATE: 10/11 /95 CK'0 BY:; DT 1 A2 i❖. .O••• 40* stoto �O• •a a iiiei 000•••••• RWIN • s•um Al TEE IVO GUARDIAN DOUBLE CONTAINED PIPING SYSTEMS DIMENSIONS Viro;Mit CARRIER/ CONTAINMENT Al A2 001 002 1/2 X 2 4.50 3.50 .84 2i38 3/4 X 3 7.00 6.00 1.05 3,50 1 X 3 6.70 5.70 1.32 3,50 1 1/2 X 4 7.75 6.75. 1.90 4.50 2 X 4 7.30 - 6.30 2,37 4.50 3 X 6 9.63 8.63 3.50 6.63 — 4 X 8 13,13 12.13 4.50 8,63 6 X 10 17,63 16.63 6.6310.75 8 X 12 19.00 18.00 8.63 12.75 D10808TE GENERAL NQTES; CARRIER — 1/2 X 2 THROUGH 8 X.12 USE WELD TEE ALL ENDS ARE BEVEL FOR WELD CONTAINMENT — 1/2 X 2 THROUGH 8 X 12 USE MITERED PIPE ALL ENDS ARE PLAIN END ALL FITTINGS ARE FACTORY TESTED ALL DIMENSIONS ARE IN INCHES UNLESS OTHERWISE INDICATED OD1': OD2', ABOVE FITTING MEETS ABTA SPECIFICATIONS: CARBON STEEL PIPE A538 & A106 SCHEDULE 10\20\40\80 '. CARBON STEEL FITTING — A234 CARBON STEEL CARBON STEEL DRAWN BY: EF DATE: 9/21/95 CK'D BY: FM REV DATE: 1(3/11/25 CK0 BY: OT 22.5 DEGREE ELBOW DIMENSIONS GUARDIAN DOUBLE CONTAINED PIPING SYSTEMS CARRIER/ CONTAINMENT Al A2 001 OD2 1/2 X 2 6.38 5.38 .54 2.38 3/4 X 3 7.25 6.25 1.05 3.50 1 )( 3 7.38 6,38 1.32 3.50 1 1\2 X 4 7.88 6,88 1.90 4.50 2 X 4 7.88 6,88 2.32 4,50 3 X 6 - 8.75 7.75 3.50 6.63 4 X 8 13.00 12.00 4.50 8.63 6 X 10 18.25 17.25 6.63 10.75 8 X 12 19.50 18.50 8,63 12.75 GENERAL NOTES: CARRIER - 1/2 X 2 THROUGH 5 X 12 USE MITERED PIPE ALL ENDS ARE BEVEL FOR WELD CONTAINMENT - 1/2 X 2 THROUGH 8 X 12 USE MITERED PIPE ALL ENOS ARE PLAIN ENO ALL FITTINGS ARE FACTORY TESTED ALL DIMENSIONS ARE IN INCHES UNLESS OTHERWISE INDICATED D108082.2 HOK; AT GUARDIAN, WE ARE cONSTAM{LY r401MnG COw 1,9CCLCTE:AS A ABOVE FITTING MEETS ASTM SPECIFICATIONS. CARBON STEEL PIPE - A539, & A106 SCHEDULE 10\20\40\80 CARBON STEEL CARBON STEEL Al DRAWN BY: EF DATE: 9/21/95 REV DATE: 10/11/95 CK 0 BY: FM CK'0 BY: DT 45 DEGREE ELBOW DIMENSIONS CARRIER/ CONTAINMENT Al A2 001 002 1/2 X 2 6.381 5.38 .84 2.38 3/4 X 3 7.25 6.25 1.05 3.50 1 X 3 7.38 6.38 1.32 3.50 1 1 \ 2 X 4 7.88 6.68 1.90 4.50 2 X 4 7.88 6.88 2.32 4.50 3 X 6 8.75 7.75 3.50 6.63 4 X 8 13.00 12.00 4.50 8.63 6 X 10 18.25 17.25 6.63 10.75 8 X 12 19.50 18.50 8.63 12.75 GUARDIAN DOUBLE CONTAINED D1080845 PIPING SYSTEMS A2 GENERAL NOTES: CARRIER - 3 X 6 THROUGH 8 X 12 USE 45 DEGREE WELD ELBOW ALL ENDS ARE BEVEL FOR WELD • CONTAINMENT - 1/2 X 2 THROUGH 8 X 12 USE MITERED PIPE ALL ENDS ARE PLAIN END ALL FITTINGS ARE FACTORY TESTED ALL DIMENSIONS ARE IN INCHES UNLESS OTHERWISE INDICATED NWM AT MAPOVH. WE ARE COHStMITLY itPRewa OUR PRODUCTS; A$ A r<-..,L7. AG C'ThC : M[ ABOVE FITTING MEETS ASTM SPECIFICATIONS: • CARBON STEEL PIPE - A53B.& A106 SCHEDULE 10\20\40\80 CARgO`1 STEEL FITTING - A234 CARBON STEEL ID1 1DRAWN BY: EF DATE: 4/8/94 CK'D BY: CS REV.DATE: 11 /07/95 CK'O BY: DT !GUARDIAN'. II DOUBLE CONTAINED PIPING SYSTEMS CLOSURE COUPLING L1 DIMENSIONS CONTAINMENT L1 ID1 2 6.00 2.50 3 6,00 3.62 4 6.00 4.62 6 6.00 6.75 8 6.00 8.75 _ 10 6.00 10.67 12 6,00 12.87 GENERAL NOTES: ALL DIMENSIONS ARE IN INCHES UNLESS OTHERWISE INDICATED SIZES 2 THROUGH B 0.0.M. SIZES 10 AND 12 FABRICATED DI0008CC C1i1 AT nuarvhs WE ARE COISTYTRY REAM. Ill CMS ME SUBJEOO TO CHANCE WITHOUT MOCCE. ABOVE COUPLING MEETS ASTM SPECIFICATION CARBON STEEL A.- 513 Pr BELOW GROUND cifa*.•7UU can c nut on... from the gm mid up. Sian Double Contained Piping Systems by Chemtxol® w Ul CC w 0- 0 0 U 2 SYSTEM Carbon Steel"/ . F VC Sch�� 80: < `_ 0y COPPER/PVC COPPER/FRP;. Stainless Steei••/ FRP Systems Options AVAILABLE SIZES JOINING METHOD FITTING AVAILABILITY V2/2 thru 18/24 Solder/ Cement Epoxy G.A.W., G.T.A.W., G.M.A.W./ Solvent Cementing TYPICAL APPLICATIONS • r .k': 1 yr ajl 7Cf ff, , r f7:ia1 fr .ldl c`,:. re d; • •P 1.:A rr c'-- Td c,ir lr rlddi Ce!lf lliaC j jij rl(`7 �.; a1 ,IVY r�1 Ze tlr r 1 gtra sr; 1 r(• �, r .✓ial:d g•Zr 1 7 r ti�.t:r Z.i 1e.; hRTI:4 r t /h.`1rti.H ' "sza3}�. J.A. sar x V�e� 90 45 ,RIa TBC TMOD Z C�FD 1//4 1/8I3 90, 45, T, R, BV, BCV, TM, D 'Z 90, 45, T,R,BV,BCV, TM, D, Z as k ,c m st . ,Organic phemicais mpeVpleum ¢products and mild ac dsnd as s a � Organic chemicals 'petreiepm q products m +soe corrosives and: concentratedacids `*• Organic_ chemicals, petroleum; •products,m some corrosives ant concentrated acsdS;-` ; Organic chemicals, petroleum 4. products, some corrosives and, mild acids. Organic chemicals, petroleum products, and mild acids and bases NOTE: 'Avail. in a wide range of schedules. "Avail. in 304, 304L; 376, 316L, and a wide range of other grades and schedules. -"Avail. in Schedule 40 and 50. Expanion loops available for all materials. FITTING CODE INDEX Pressure 90=900 elbow • 45=450 elbow • T=Tee • R=Reducer Fittings: BV= Ball valve•BCV= Ball check valve•TM=Termination D=Discs • Z=Zone anchor DMV Fittings: C=Cleanout • FD=Floor drain • 1/4B=1/4 Bend, 1/8B=1/8 Bend•1/16B=1/16 Bend•ST=Sanitary tee P= P-Trap • W= Wye • Combo= Wye and 1/8 Bend GUARDIAN DOUBLE CONTAINED PIPING SYSTEMS INTRODUCTION AND OVERVIEW Concerns over chemical leaks, and spills have been mounting over the past several years. A'number of''. social, legal and safety issues confront industry today. Pollution of soil and subsoil due to spills and Leaks' eventually Leads to groundwater contamination. Every day we read stories about soil and water contamination and the huge pollution problem facing our nation. On November 8, 1984, President Reagan signed into law the Hazardous and Solid Waste Amendments. This law requires the individual states to either accept the federal law as written or develop their own. more stringent standards. To date, the majority of states have developed their own final regulations. The regulations requiring the use of double containment technologies are as follows: • Petroleum Pumping and'Tanks mandated by RCRA written as federal law 40 CFR 280. • Hazardous Substance Piping and Tanks mandated by RCRA Subtitle I, written as federal law 40 CFR 280. Tanks and piping that are included under the RCRA regulations, also referred to as the UST regulations, include: • All containing regulated substances as defined in the above mentioned regulations. • Systems where 10% or more of their total volume are below the ground surface. • Tanlless piping systems where 10% or more of their volume is below the ground surfaces. The risks from leaking UST's and related piping include health, safety, fire, explosion,, contamination, clean-up cost and liability, just to name a few. The EPA findings are over 3,000,000 existing systems in the U.S.A. Presently 100,000 UST's are leaking, and it is estimated that 350,000 UST's will be leaking by the year 2000. EPA findings also indicate two-thirds of the Teaks will be caused from pipe'. failures. Unfortunately most leaks are detected only after major soil contamination has occurred. The EPA has also done clean-up estimates that range from $35,000 to over $1,000,000. It is important, to note that these estimates include excavation, soil testing, groundwater clean-up and total replacement of UST system. Guardian Double Containment Piping Systems have been specifically designed as complete package to, meet these requirements. Whether the service is drainage or pressure, above ground or below, Guardian builds a system to meet the requirements. With a wide selection of materials to choose from, including, steel, stainless steel, PVC, CPVC, fiberglass, PP, PE and PVDF, there is a system to meet your specific, requirements. Unique assemble and testing techniques allow unsplit components ready for installation. Potential leaks are eliminated by using standard joining techniques used in the piping industry. The easier a system is to install, the greater the chance of success. Complete contractor training is available by, factory experts to insure installation integrity. Interest in double containment piping will continue to grow far into the future. Guardian will continue to manufacture systems designed to exceed the service conditions while remaining as simple to install as. possible. BELOW GROUND CARBON STEEL. \ FIBERGLASS NM AT IMMO M, FC OM CONSTANTO r" ckL nw 9 MC M RESULT,5ueACT To CPWNCC 1m oor NOTICE DRAWN BY: EF DATE: 9/26/95 REV DATE: 10/11/95 DIMENSIONS CK'D BY: FM C8'0 BY: DI GUARDIAN DOUBLE' CONTAINED DI0810P1 PIPING SYSTEMS CARRIER/ CONTAINMENT L1 L2 OD1 002 1 /2 X 2 20' 5' .84 2.38 3/4 X 3 20' 5' 1.05 3.50 1 X 3 20' 5' 1.32 3.50 1 1/2 X 4 20' 5' 1.90 4,50 2 X 4 20' 5' 2.38 4.50 3 X 6 20' 5' 3.5D '.6.62 4 X 8 20' 5' 4.50 8,62 6 X 10 20' 5' 6.62 10.75 8 X 12 20' 5' 8.62 12.75 GENERAL NOTES: CARRIER - ALL ENDS ARE BEVEL FOR WELD CONTAINMENT - ALL ENDS ARE PLAIN END PIPE IS SHIPPED BUNDLED AND ENDS ARE REINFORCED AND WRAPPED TO PREVENT DAMAGE. ALL DIMENSIONS ARE IN INCHS UNLESS OTHERWISE INDICATED' DOUBLE RANDOM LENGHT P.O.A. ABOVE: RIPE' MEETS ASTM SPECIFICATION CARBON STEEL PIPE - A53B & A105 SCHEDULE 10 20\40\80 FIBERGLASS, PIPE - 02996 PIPE \ FITTING SUPPORT DIMENSIONS DRAWN BY: K.G. DATE: $/23/95 REV DATE: 11/21/95 CK'D BY: CK'D BY; DT CENTRA-GUIDETM f WING LENGTH NOTE #1 NOTE #2 GENERAL NOTES: GUARDIAN DOUBLE CONTAINED PIPING SYSTEMS 1. LENGTH IS SIZED TO FIT BORE OF CONTAINMENT PIPE. 2. I.D. SIZED TO PROVIDE NON -SLIP AGAINST CARRIER PIPE CLIP 15 APPROX. 2" WIDE 120° SIZE SSIIZEK "I.0. WING LENGTH PART # 1/2" .19 .83 1.75 728007 I 3/4" .19 1.04 1.75 728008 1" .25 1.30 _ 1.25 728009 1 1/2" .25 1.89 1.10 728011 2° .25 2.36 2.13 728012 3" .38 3.49 1.50 728014 4" .38 4.49 1.75 728016 6" .50 6.61 1.75 728018 8" .50 8.61 1.75 728019 10" .75 10.70 2.00 728020 GENERAL NOTES: ALL DIMENSIONS ARE IN INCHES UNLESS OTHERWISE INDICATED MOLDED POLYPRO D10004CG matt AT GUARDIAN, v( ME CO"STWWU • BPRONNc COO PRJOVc1S: AS A RESULT. ALL OWEWNNS ARE SUBJtT TA cwooc 1x11-CUT )'C107,. ABOVE CENTRA-.GUIDE"' MEETS ASTM SPECS: BLACK POLYPROI - 04101 CARBON STEEL \ FI.BERGLASS 90 DEGREE ELBOW • O'l A2 Al IMENSIONS 001002 DRAWN BY: EF DATE: 9/26/95 REV. DATE: 10/11/95 CARRIER/ CONTAINMENT Al A2 OD1 OD2 1/2 X 2 7.00 6.00 .84 2.38 3/4 X 3 7.38 6.32 1.05, 3.50 1 X 3 7.75 6.75 1.32. 3.50 1 1/2 X 4 9.25 8.25 1.90 4.50 2 X 4 9.00 8.00 2,38. 4.50 3 X S '11.50 10.50 3.50 6.63 CK'0 BY; FM cK'D . BY: OT GUAR-NAN' DOUBLE CONTAINED PIPING SYSTEMS 90 DEGREES ELBOW 'Al DI08,1090 WM. i• «11 » MENSIONS OD1. 002 CARRIER/ CONTAINMENT Al A2 001 002 4 X 8 15;00 14;00 4.50 6.63 6 X 10 17163 16.63 6.63 10.75 8 X 12 19500 18:00 8.63 12.75 GENERAL NOTES: CARRIER — 3 X 6 THROUGH 4 X 8 USE LONG RADIUS 90 DEGREE WELD ELBOW — 6 X 10 THROUGH I 6 X 12. USE SHORT RADIUS 90 DEGREE WELD ,ELBOW ALL ENDS ARE BEVEL FOR WELD CONTAINMENT 1— 4/X 8 THROUGH 6 USE 8 X 12USEMITERED & WRAPPED 90 DEGREE MOLDED ELBOW ALL ENDS ARE PLAIN! ENO ALL FITTINGS ARE FACTORY TESTED ALL DIMENSIONS ARE IN INCHS UNLESS OTHERWISE INDICATED Mt AT GOMM. ME ME EOMgTN+D.Y � pit .&? All MM 'E A SImJEO! TO Owlet1TITA09T TILE. ABOVE FITTING MEETS ASTM SPECIFICATIONS: CARBON STEEL PIPE — A538 & A106 SCHEDULE 10\20\40\80.. — g234 CARBON STEEL FITTING FIBERGLASS:: PIPE — 02996 FIBERGLASS: FITTING — 02996 CARBON STEEL \ FIBERGLASS 45 DEGREE ELBOW DIMENSIONS DRAWN BY:. EF DATE: 9/26/95 REV. DATE: 10/11/95 CK'D BY: FM CK'D BY: DT GUARDIAN DOUBLE 'CONTAINED PIPING SYSTEMS D1081045 45 DEGREE 'ELBOW A2,' Al. Oo1 CARRIER/ CONTAINMENT , Al A2 OD1:002 1/2 X 2 6.38 5.38 .84 2.38 3/4 X 3 7.25 6.25 1.05 3.50 1 x 3 7.38 6.39 1.32 :3.50 1 1/2 X 4 7.88 6.88 1.90 4.50 2 X. 4 7.88 6.88 2.38 4.50 3 x.. 6 8.75 7.75 3.50 6.63 AT GIJMUYL we .RE cowSYw TLy uPRTARO OuM PRODUCTS: AS A 'rowoSotsufwEcT soenu • DIMENSIONS CARRIER/ CONTAINMENT Al 1A2 OD1 002 4 :X 8 13.00 12.00 4.50 8.63 6 X 10 16.250.25 6.63 10.75 8 x 12 19.5018.50 8.63 1,2.75 GENERAL NOTES: CARRIER - 3 X 6THROUGH 8 X 12 USE 45 DEGREE WELD CLBOW ALL ENDS ARE BEVEL FOR WELD CONTAINMENT - 1/2 X 2 THROUGH 3 X 6 USE MOLDED 45 DEGREE ELBOW. - 4 X 5 THROUGH 8 X 12 USE MITERED 84 WRAPPED PIPE .ALL ENDS ARE PLAIN END ALL FITTINGS ARE FACTORY TESTED ALL DIMENSIONS ARE IN INCHS UNLESS OTHERWISE INDICATED ABOVE FITTINQ MEETS ASTMSPECIFICATION: CARHBON EEL 10\20\40\80 - A53B & A106 CARBON STEEL FITTING - A234 FIBERGLASS PIPE - D2996 FIBERGLASS FITTING - 02996 CARBON STEEL,\ FIBERGLASS TEE DIMENSIONS DRAWN BY: EF DATE: 9/26/95 REV. DATE: 10/11/95 CARRIER/ CONTAINMENT AI A2 OD1 002 1/2 X 2 7,00 6,00 .84 ,2,38 3/4 X 3 7.36 6.32 1.05 3.50 1 X 3 7.75 6.75 1.32 3.50 1 1/2 X 4 9,25 6.25 1,90 4.50 2 X 4 9.00 8.00 2.38 4.50 3 X 6 11,50 10.50, 3.50 6.63 AT alums% we ARE caa*wnr IYORQ,MG Wn vnuttcT& /5. 40W /u DIIVeSI0*5 ARE 51.44Tet TO Cw1a: ifftroUT CK'O By; FM CRT) BY: DT GUARDIAN DOUBLE CONTAINED I', D1081 OTE PIPING SYSTEMS CARRIER/ CONTAINMENT AI A2: OD1 OD2 4 X 8 13.13 12.13 4.50 6.63,, 6 X 10 17.63 16.6:3 6.63 10.75 8 X 12 19.00 18.00 8.63. 12.75 GENERAL NOTES: CARRIER - 1/2 X 2 THROUGH 3 X 6 USE SOCKET WELD TEE - 4 X 8 THROUGH 8 X 12.USE BUTT WELD TEE ALL ENDS ARE BEVEL FOR WELD CONTAINMENT - 1/2 X 2 THROUGH 3 X 6 USE MOLDED TEE - 4 X 8 THROUGH 8 X 12 USE MITERED & WRAPPED PIPE ALL END ARE PLAIN END ALL FITTINGS ARE FACTORY TESTED ALL DIMENSIONS ARE IN INCHS UNLESS OTHERWISE INDICATED ABOVE FITTING 'MEETS ASTM SPECIFICATION' CARBON STEEL PIPE - A538 & A106 SCHEDULE 10\20\40\80, CARBON STEEL; FITTING - A234' CARBON STEEL FITTING - A105 FIBERGLASS PIPE - D2996 FIBERGLASS FITTING - 02996 CARBON STEEL \ FIBERGLASS rot: AT GWNGNN. WE AGE GG6tM'RY l/VMVMG WypPRODUCTSf XI s•A AWLS to GWNCE 1RTMWR DRAWN BY: EF DATE: 9/26/95 CICD BY: FM REV DATE: 10/11/95 CK'O BY:.DT GUARD}AN DOUBLE ;CONTAINED PIPING SYSTEMS 22.5 DEGREE ' ELBOW CARRIER/. CONTAINMENT . Al - A2 OD1 OD2 1/2 X 2 6.38 5.38 ' .84 2,38 3/4 X 3 7.25 6.25 1,05 3.50 1 X 3 7.38 6.38 1.32 3.50 1 1\2 X 4 7.88 6.88 1.90 4.50 2 X 4 7.88 6.88 2.32 4.50 3 X 6 8.75 7.75 3.50 6.63 4 X 8 13.00 12.00 4.50 8.63 6 X 10 18.25 17.25 6.63 10.75 8 X 12 19450 18.50 8.63 12.75 GENERAL NOTES! CARRIER - 1/2 X 2 THROUGH 8 X 12 USE MITEREDPIPE ALL ENDS ARE BEVEL FOR WELO CONTAINMENT - 1/2 X 2 THROUGH 8 X 12 USE MITERED &f WRAPPED PIPE ALL ENDS ARE PLAIN END ALL FITTINGS ARE FACTORY TESTED ALL DIMENSIONS ARE IN INCHS UNLESS OTHERWISE INDICATED: D1081022 ABOVE FITTING MEETS ASTM SPECIFICATION: CARBON $TEFL PIPE - A53B & AIOE SCHEDULE 10 20\40\80 - p2996 FIBERGLASS PI E, STYLE C TERMINATION FITTING \ TEST FITTING CARRIER PIPE DRAWN BY: EF bATE; 7/18/95 REV DATE : 10/16/9! ELASTOMERIC PVC MATERIAL 2.5" TO 5.5" THICK AIL 14k. 'IFS I% rip ' AliztAtOls CONTAINMENT PIPE VALVE /:TEST PORT ( OPTIONAL ) 1/8 INLET INSTALLATION PROCEDURE ALL' STYLE C FITTINGS ARETO SITE COMPLETELY TERMINATIONSHIPPED AND READY FOR EFFIELD INSTALLATION. SIMPLY SLIDE THE TERMINATION FITTING OVER THE CARRIER PIPE AND :INTO THE END OF THE CONTAINMENT PIPE, RECESSING IT APPROXIMATELY ONE INCH FROM TH. CONTAINMENT PIPE END. AS THE BOLTS ARE TIGHTENED, THE END PLATES COMPRESS THE ELASTOMERIC MATERIAL CREATING A SEAL BETWEEN THE CARRIER ANO CONTAINMEI PIPE. TIGHTEN ALL BOLTS FOLLOWING THE TORQUE SEQUENCE WHEN HOPE, POLYPRO, PVDF AND FRP CONTAINMENT PIPES ARE USED, INSTALLATION OF A RESTRAINING COLLAR IS NECESSARY. NOTE : I.D. AND :0.D. OF TERMINATION FITTING ARE SIZED PER SPECIFIED CARRIER ANO CONTAINMENT PIPE. CK'D BY: C. S. CK'D SY: DT GUARDIAN DOUBLE CONTAINED. PIPING SYSTEMS END ;VIEW D10000CT INSTALLATION '1 F MAX. TORQUE 8 FT "LBS 8 FT ''LBS 8 FT,LBS 8 FrT-LBS 8 FT' LBS 10 FT,', LBS 10 FTLEIS 10 FT LBS _.i THE CONTAINMENT PIPE JOINTS, IT _..aARY TO FIRST SEAL THE INTERSTITIAL SPACE .GATED AT BOTH ENDS OF THE PIPE RUN. ' SECONDLY PROVIDE A PORT TO PRESSURIZE AND DEPRESSURIZE THE SECTION OF PIPE To BE TESTED. THIS TEST FITTING IS DESIGNED TO SEAL. THE ' INTERSTITIAL SPACE AND PROVIDE A PRESSURIZATION PORT FOR TESTING PURPOSES. WHEN. PERMANENTLY INSTALLED IT ACTS AS A TERMINATION FITTING WITH A DRAIN VALVE. IT I5 ALSO USED TEMPORARILY TO TEST CONTAINMENT JOINTS! IN • SUBASSEMBLIES • BEFORE JOINING TO YOUR; NEXT SUBASSEMBLY. SUCCESSFULTHEEFITTINBE REMOVED AND TEST COMPLETED. NCR: 111PPON WR PRQOIIWC ARC CTS;si/4 tY RESULT ILL OINERSION5 ME SMUT TO GWNCE WINO)! NCIICE CAUTION ; NEVER EXCEED 101 PSI ( PNEUMATIC ) WHEN TESTING PLASTIC CONTAINMENT PIPING! F R P KIT CONTAINS: DRAWN BY: K.G. DATE:. 1/15/96 REV DATE: GUARDIAN lcWD EY: DT DOUBLE CONTAINED CK'D BY: PIPING SYSTEMS CLOSURE COUPLING OUTER SECTIONS (2) (I.D. SANDED. ONLY) INNER SECTIONS (2) (I.D. & O.D., SANDED) WORM CLAMP (2) 2—INNER 180 DEGREE FRP SHELLS-- 1.0. & O.D. DE —GLOSSED 2—OUTER 180 DEGREE FRP SHELLS-- 1.0. OE —GLOSSED 2—WORM CLAMPS. 1—EPDXY RESIN/HARDENER BONDING KIT 2—MIXING STICKS, GLOVES. SAND PAPER AND A BRUSH CARRIER PIPE CONTNNMENT PIPE• ADHESIVE REQUIREMENT CHART (5oz. KITS) p10010CC PIPE ADHESIVE SIZE REQUIRED 3" 4.. 6" 6" 10- 12" 1/2 2 2 3 3 HCTL AT WAaul we E [K�off T Y WPAOMAHC OUR 4M RESULT, ALL 00.074IONE su&2CT TO Cw+roE YAwH0u` 'CLOSURE COUPLING MEETS AST M SPECIFICATIONS: .FRP —02996 Clean Fuel Incorporated Hulk -Stored Diesel Fuel.Oual Bulk -Stored Fuel. Quality Maintenance Systems Fuel Guardian CFI 6 Description: The CFI Fuel Recirculator is a self- contained, timed -cycle device for maintaining the quality and purity of stored diesel fuel. The system effectively removes water and solid contaminants down to 2 microns in size and assures the availability of clean fuel to your stand-by diesel generator. It has the capacity to service bulk - storage tanks up to 25,000 gallons in size, and a variety. of standard and optional features. CFI units are attractively housed in a rugged steel cabinet with hinged lid for easy installation and service. Only the highest quality components are used throughout to assure prolonged, trouble -free operation. Each unit consists of five main components: 1. An external control panel - for selecting the modes of operation, indicators to show system status and alarms to signal the need for operator intervention. 2. A three stage filtration module - for removing water and solid contaminants. 3. An electronics module - for controlling pump operation and monitoring fuel and filter condition. 4. A pump module - for circulating the stored fuel through the filtration module and back to the storage tank. 5. An automatic water drain module for removing excess water as it accumulates in the filtration module. DIESEL GENERATOR RETURN DAY TANK PUMP SUPPLY rCENTRIFUGE n- COALESCING PLATE (80 MICRONS) FILTER (2 MICRONS) PUMP System Description Standard Features Main On -Off Switch - Located inside the liquid tight enclosure, this switch provides thermal overload protectionfor the pump, motors and allows the timer to keep running regardless of the setting of external selectors. Main Fuse - Part of the electronic module is a 20 amp fuse to protect all primary wiring and components from overload. Secondary Fuse - An additional fuse is provided to protect all -.. secondary 12 VDC wiring and components from overload. 24 Hour Timer The timer allows the user to adjust the duration of pump cycle time to fit his particular installation. It is recommended that the entire contents of the bulk -storage tank be circulated twice each week. 12. VDC Power Section - All probes operate on low voltage for safety and ease of wiring to remote location. Electrical Enclosure - All electrical switching and controlling devices are contained in a rugged, NEMA rated, liquid tight enclosure for added safety. Wiring - All primary wiring is heavy-duty 14 AWG, rated for 600 V, and type THHN oil resistant. Wiring outside the liquid tight enclosure is encased in liquid tight conduit for added safety and durability. Motors - All motors are heavy-duty, fully enclosed, ball bearing, fan -cooled and thermally protected to provided years of troublefree services. Circulator Pump - The main circulator pump is a heavy duty, industrial, positive displacement unit. It is completely sealed and requires no maintenance. Filtration Module - The cannister is manufactured to the most rigid standards and contains three replaceable filter elements. Elements are available with ratings from 30 down to 2 microns. Replacement elements are available from CFI at a nominal charge. Changing elements is easily done by simply removing the cannister lid. A petcock valve is conveniently located in the cannister lid for relieving any pressure/vacuum inside. External Selectors - Two selectors are provided for choosing continuous manual operation or automatic time -cycled operation and automatic drain. Pilot lamps are providedfor indicating the `different operating modes to show when the automatic water drain pump is operating. Monitor/Alarm - The device indicates by an audible alarm that operator intervention is required. A green.indicator light shows that the monitor is activated and the CFI-6 System is operating. BULK STORAGE TANK. RECIRCULATING/ FILTRATION SYSTEM Should water in the filtration module rise to a critical level', the audible alarm will sound. The excess water must be removed before the system can be reset. Compound Gauge - Once a base gauge reading with dean filters is established, this gauge will indicate when it is necessary ,to replace filter elements. See Optional Features. Remote Location Monitoring - The electronic'module houses a 12 position terminal strip which is provided for setting off alarms or activating lights in a remote locationto indicate: the exact status of the unit. In this way the user can customize his installation based on his unique requirements. Cabinet - Each CFI unit is housed in a heavy duty welded,. custom cabinet. All major metal components are first coated with rust inhibiting primer then sprayed with an attractive two tone, green and white finish coat. Optional Features Pressure/Vacuum Differential Switch - This optional feature alerts the user (audible alarm and warning light) that the filter elements need replacing or that the flow of fuel through thee. system has been interrupted. Manual Water Drain - The system is available without the standard automatic water drain. Althoughthe units have the same external appearance their controls differ slightly and;when the user is warned of excessive water in the filtration module ('audible alarm) the user must manually drain the water from the system. These units may be field upgraded to automatic drain models. Custom Installation - Check with out technical staff if you have special requirements. Specification: CFI 6A-;D II • Pump Capacity: 6 GPM • Voltage: 110 VAC • Dimensions: 32" W x 24' D xx 48" H • Approximate Shipping Weight: 440 LBS. jclean Fuel Incorporate, 1208 West Marshall Street • Richmond, Virginia 23220-3024 • (804)358-7415 • FAX (804) 359-256,3 FUEL GUARDIAN SYSTEM Standard One Tank Installation i TO OAY TANK WWII MOM fENEMTOE PRIMARY SUPPLY UNE r-- TANK 0 CHECK VALVE SUPPLY 1 RETURN 1 � Q 1 IN I ILLUSTRATION SHOWS TANK BEING CLEANED CFI OUT 1 NOT TO SCALE TOP REAR CABINET — EACH CFI UNIT IS HOUSED IN A HEAVY DUTY WELDED STEEL CUSTOM CABINET. ALL MAJOR METAL COMPONENTS ARE FIRST COATED WITH RUST INHIBITING PRIMER THEN SPRAYED WITH AN ATTR— ACTIVE TWO— TONE . GREEN AND WHITE FINISH COAT. LEFT SIDE FRONT Cla Fuel Rujde *ten . —J f� Clean NFtel Inc. Nw Ikea v.. T RIGHT SIDE soon 0 el Or ful kFk Ste CFI-6 AUTO DRAIN CABINET DATE: 05— 21-1997 DRAWN BY: SR 32" 24" i FRONT t CONTROL PANEL: THE CFI-6 IS SUPPLIED WITH A 10" SO CORD WITH A GROUNDED MOLDED PLUG. A 20 AMP 110 VOLT CIRCUIT IS REQUIRED. THE KNOCK -OUT HOLE INDICATED IS FOR ENTRY TO REACH THE REMOTE CONTACTS LOCATED ON THE THE BOTTOM OF THE CONTROL PANEL, TB2. STATUS AND ALARM TERINAL BLOCK "TB2" CONDITION CONTACTS: NORMALLY OPEN -CLOSED WHEN CONDITION EXIST 1 & 2 PRIMARY PUMP ON 3 & 4 AUTO ORAIN PUMP ON 5 & 6 CHANGE FILTER ALARM 7 & 8 HIGH WATER ALARM OPERATING CONTACTS: FOR ENERGIZING OR INTERRUPTING POWER TO SYSTEM 9 & 10 REMOTE START/STOP 11 & 12 FLOAT START/STOP CLEAN FUEL INC. 1208 W. MARSHALL ST. RICHMOND, VA. 804- 358- 7415 CFl-6SR ELEC 5-21-97 FRONT , UNIT MAY BE PIPEDWE 00 NOTRE DR U. HOLESUTHE BOTTOM SO THAT THEY MIS OPEN. MAY BE MADE IN THE FIELD TO ACCOMODATE EACH INDIVIDUAL. SITE. WATER UNE'MUST BE RUN TO SOME TYPE OF CONTAINMENT VESSEL, SO` THAT IT MAY BE DISPOSED OF AS USED OIL. "USED OIL DESTINED FOR DISPOSAL" IS NOT CONSIDERED A HAZARDOUS WASTE, CONSULT LOCAL CODES REGARDING. DISPOSAL OF USED OIL. HEIGHT FROM FLOOR FOR CONNESTIONS CLEAN FU0. INC. INPUT/SUCTION 2T' 120A W. MARSHALL ST, OUTESSURE 13" RICHMOND, VA. WATER -DRAIN 11" S0�3gg-7415 F- w U) w Cn N Z cc CL T O O E C O� - Q Q CC Cn T C0 CC --I w F- T Z w < CC O f- cc p d U J w a I- 0 w w Q, Z Q T = ° cwn C.)C C r COCO 00 CO OJ w 0u Z r U ,n r I Cr N 0 Cl.UJ CO Z O N CD >- O Cr rLCz Z a It p w O p Z CL CC w z �= Ow P - M CL ca a � ¢ Q w co � cc < L O z O O p O w N z O a_ < 0 CC 0 F_- CV "Cr CD r T C] o6 00 Q 00 Z CC O r ch w �' U CL 0 U-1 F- N FUEL GUARDIAN 0 n • W • • g W 0 J 01 rn N CO m i 0 CI Clean Fuel Incorporated 1208 West Marshall Street Richmond, Virginia 23220-3024 (804) 358-7415/FAX # 804-359-2563. CFI-89 WATER COLLECTION DRUM - 55 GALLON Polyethylene Drum with See -Through Scale COMPLETE KIT INCLUDES: * 55 GALLON DRUM WITH SEEIJTHRU SCALE * POLYPROPYLENE HAND PUMP * FITTINGS & TUBING IN -PUT WATER LINE QUICK DISCONNET HOSE FITTING - OTHER END TO DRAIN PUMP 1/2' HOSE 12' LONG. LOW VOLTAGE WIRING \_lf� I �TT FLOAT SWITCH TO STOP FUEL GUARDIAN SYSTEM OPERATION AND SOUND ALARM WHEN TANK IS FULL. QUICK DISCONNET, PLUG - OTHER END G❑ING TO MACHINE 12' LONG. COMPLETE KIT INCLUDES N 55 GALLON DRUM WITH SEE THRU SCALE * POLYPROPYLENE HAND PUMP x FITTINGS AND TUBING A( FLOAT SWITCH INCLUDING 12 FT. WIRING AND QUICK DISCONNET. CLEAN FUEL INC. RICHMOND,AVA ALL ST, CFI-89 WATER COLLECTION DRUM 55 GALLON 09-02-97 i 33' EMERGENCY CONTAINMENT FOR ANY POTENTIAL FUEL 'SPILLS. CAPACITY --13,4 GALLONS OPERATES WITH FLOATAND KILL SWITCH TO STOP SYSTEM OPERATION AND SOUND ALARM AT APPROXIMATELY 3 GALLON LEVEL PLACE FUEL GUARDIAN SYSTEM INTO THE RUPTURE BASIN ALLOWING 1/2' CLEARANCE ALL AROUND, CLEAN FUEL INC. 1208 W. MARSHALL ST RICHMOND, VA, CFI-6 RUPTURE. BASIN DATE+ 09-02-97 �' Clean Fuel Incorporated ■ 1208 West Marshall Street Richmond, Virginia 23220-3024 (804) 358-7415/FAX # 804-359-2563 FUEL GUARDIAN WARRANTY STATEMENT, These Warranties are giving ONLY to purchasers who buy for commercial or industrial use in the ordinary course of each purchaser's business. General Clean Fuel Inc. products and systems are in our opinion the finest available. We take pride in our products and service and are pleased that you have chosen Clean Fuel products. Please read your Warranty Statement carefully. This statement sets forth our responsibilities in the unlikely event of defect and tells you how to obtain performance under Clean Fuel's warranties. The Clean Fuel system warranted below, which for these warranties consists of a metal framed cabinet, pumps, motors, gauges, valves, three stagecanister and'. control housing, identified below is warranted to be free of defects in material and workmanship for a period of one year against defects in material and workmanship applicable to the System identified below. If any part of portion of the System fails to conform to the characteristics warrantedwithin the warranty period, Clean Fuel will furnish new or (at its option) factory remanufactured material for repair or replacement of that part of portion. Warranty Extends to First Purchaser for Use, Nontransferable These warranties are extended to the first person, firm, association or corporation for whom the System identified herein is originally installed for use (the "User"). These warranties are not transferable without the prior written permission of Clean Fuel Inc. Assignment of Warranties Clean Fuel assigns to the User any warranties which are made by manufacturers and suppliers of components of the System and which are assignable, but seller makes NO REPRESENTATIONS as to the effectiveness or extent of such warranties and assumes NO RESPONSIBILITY for any matters which may be warranted by such manufacturers or suppliers. Obtaining Performance Under These Warranties Within a reasonable time (but in no case to exceed 90 days) after discovery of a defect, the User should communicate with the person from whom the System was purchased or, at the User's option, with Clean Fuel directly. Subject to the policy set forth in the section immediately following, Clean Fuel will repair or replace (at its option), without charge for material, subsequent to its inspection and F.O.B. its plant, any portion of materials warranted hereunder which does not conform to the characteristics of these Warranties. If replacement parts or components are shipped or caused to be shipped by Clean Fuel prior to inspection of the part or portion shall be invoiced in the full current price amount and shipped'. freight collect. Credit will be allowed only after Clean Fuel's inspection discloses the claimed defect and shows no signs of treatment or use which would void the coverage of these Warranties. Warranty Performance of Component Manufacturers It is Clean Fuel's practice, consistent with its desire to remedy warranted defects in the most prompt and effective manner possible, to cooperate with and utilize the services of component manufacturers and their authorized representatives in the performance of work to correct defects. Accordingly, Clean Fuel may utilize third parties in the performance of warranty work, including repair or replacement hereunder, where, in Clean Fuel's opinion, such work can be performed in Less time, with less expense and in closer proximity to the System. The User may be instructed to deal directly with those third parties for certain warranty services. Of course, Clean Fuel is depending upon such third parties to perform the, services warranted and welcomes the User's comments in regard thereto. Items Not Covered By Warranties THIS WARRANTY DOES NOT COVER DAMAGE OR DEFECT CAUSED BY misuse, improper application, wrong or inadequate electrical current or voltage, negligence, accident in transit, tampering or alterations, changed location or operating use, installation contrary to Clean Fuel's or component manufacturer's recommendations, or in any event if the Clean Fuel serial number tag has been altered, defaced or removed. THIS WARRANTY DOES NOT COVER shipping costs, installation costs, maintenance and service items, including but not limited to filters, cleaning, lubrication, calibration and adjustment and further, does NOT include labor, or transportation charges incidental to the replacement of the System or any part thereof or charges to remove the same from any premises of the User. THIS WARRANTY DOES NOT COVER repair or replacement, or the costs associated therewith, of electrical controls, relays, filters, fuses or indicator' bulbs, or any other losses or expenses incurred in operation or installation of the System. REPAIR OR REPLACEMENT OF A DEFECTIVE PART, OR THE CREDITING TO THE USER OF THE VALUE THEREOF, DOES NOT EXTEND THE ORIGINAL WARRANTY PERIOD. Limitations THIS WARRANTY IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES,EXPRESS OR IMPLIED,INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE LIABILITIES OF CLEAN FUEL INC. ARE LIMITED SOLELY AND EXCLUSIVELY TO REPAIR OR REPLACEMENT AS SET FORTH HEREIN ALONE AND DO NOT INCLUDE ANY LIABILITY FOR ANY INCIDENTAL, CONSEQUENTIAL OR O PHER DAMAGES OF ANY KIND WHATSOEVER, WHETHER ANY CLAIM IS BASED UPON THEORIES OF CONTRACT, NEGLIGENCE OR TORT. Miscellaneous NO SALESMAN, EMPLOYEE ORAGENT OF CLEAN FUEL INC. IS, AUTHORIZED TO VARY THE TERMS OF THIS WARRANTY STATEMENT. This is the Clean, Fuel Inc. Warranty Statement in effect as of shipment and supersedes all previous warranties. It may be supplemented or changed from time to time. In the event that any provision of these Warranties should be or become invalid and/or unenforceable during the warranty periods, the remaining terms and provisions hereof shall continue in full force and effect. This warranty is given in,, and is intended to be construed under the laws of, the State of Virginia. • Clean Fuel Inc. will require evidence of date of shipment at the time any remedy or performance under this warranty is sought. (Purchaser) User Model Number Serial Number Date of Shipment Warranty Expiration Date Environmentally Safe' Never`' Double -Wall Fiberglass Tanks For' Underground. Petroleum ._Storage Maximum safety, maximum reliability, maximum return on investment. Fluid Containment Inc. Cont.',1, - . . Advantages •Double -Wall Tanks from Fluid Containment Our fiberglass tanks have been exhumed after 6. 12, 15and 21 years of gasoline service and shown noloss in their original (structural) properties. Advantages......... .:... ........2 Manufacturing Processes Research & Development ........: .........5, 's Gasoline, & Fuel Oil Systems Overviews 6 Monitoring 10 Tank Drawings 13 Accessories 24 Warranty/ Specifications .......: ........32 Why our tanks are your best investment. The fiberglass underground storage tank owes its very existence', to the shortcomings of steel tanks — and their resulting environmental problems. In the early 1960's,,the American Petroleum Institute challenged (we were then known as the Special 'Products. Division of Owens-Corning) to develop a rustproof underground storage tank that would be safe and strong enough to satisfy the petroleum industry's most stringent long-term storage demands. Our engineers accepted the challenge. and pioneered the underground fiberglass tank technology. The major oil companies responded to our achievement by specifying fiberglass tanks for approximately 90% of their underground fuel storage installations. Their keen awareness of the limitations of a steel tank in a corrosive environment and their confidence in fiberglass tank technology helped us earn a reputation for safe, rust -free, long-term, underground storage in approximately 250,000 installations over the last 30 years. L. Along the way, we've earned a leadership position in this industry. Our pioneering design work resulted in the UL 1316 specification which governs fiberglass tank manufacturing. As the inventors of fiberglass underground storage tank technology, many: of the basic patents on products that have become industry standards began with Owens-Corning and continue with Fluid Containment today and in the future. Fluid Containment manufactures Single Wall & Double Wall Fiberglass Underground Storage Tanks Leak Detection Systems Oil/Water Separators ReTank Retrofit Systems Storage Tank Anchor Systems Fiberglass Manholes & Wetwells L We will continue to lead, far into the future, thanks to the vision of everyone on our team. Every one of our employees brings a, tremendous amount of pride to what we do: • Our rigorous dedication to research and development. Our newly expanded R&D facility focuses its considerable talents on pushing the limits of what is possible and practical, to provide you with products that meet your needs at a competitive price, while offering the highest quality. • Our technologically -superior manufacturing process leverages the finest materials and methods to produce high -quality products that have led the industry for over three decades. • Our industry -leading support. We have the most knowledgeable direct field sales force, and the only national field ser- vice organization staffed by full-time company. employees. They, along with our superb inside sales group, are committed to supplying "value-added" service that complements our exceptional products. Our customer service and technical support group promptly and clearly answers any, technical question about our products or services. All of which adds up to Fluid Containment people going above and beyond to deliver the highest quality and best long-term value in underground storage technologies that you can invest in. All of us at Fluid Containment invite you to review our state-of-the-art products at three conveniently located manufacturing facilities in Bakersfield, CA, Conroe, TX and Mt. Union, PA. Because only then will you understand the depth and breadth of our advantages — and our pride which is evident in every product we make. :our products carry the Underwriters The product of precision engineering and forward thinking.'' The process by which our fiberglass tanks are manufactured speaks volumes about their quality, integrity, safety and longevity. Since the very first non -corrosive tank was designed back in the 1960's, we have maintained the highest quality standards and leveraged promising technologies to engineer and build the world's premier fiberglass storage tank. Our tanks are made on !steel molds from the inside out. We use steel mandrels (cylindrical steel molds) and build our tanks from the inside out. Steel molds provide us with a firm and consistent surface, upon which we apply materials to make our tank. The rotation of the mandrel and the. application of the materials are controlled by a computer, custom designed to manufacture underground tanks. As the mandrel rotates, resiri, glass, and specially treated silica are precisely metered onto the mandrel from above. The result is a closely controlled process and a very consistent tank wall composition and thickness: After the tank wall is made, its thickness is precisely determined; An instrument' that magnetically senses the metal mold surface through the fiberglass reinforced plastic laminate is used to accurately measure the thickness of the laminate at many points all over the surface of the tank wall. This method of thickness measurement with a metal mold is quick, easy, and more exact than the ultrasonic methods used by other manufacturers. Stronger tanks, inside and out The inside out approach to building the tank wall has some other advantages as well. The first layer of materials forms the inside surface of the tank. Because of the smooth steel mold, the inside surface of the tank is very smooth and free of surface variations. The inside surface is not exposed to air as it cures which eliminates the air inhibited surface cure problems sometimes associated with other methods. The result is a well cured and very smooth tank interior that will be exposed to the fuel in the tank. By applying materials to the outside of the tank, we can easily add additional thickness, reinforcing ribs, filament winding glass in tension, glass woven roving, glass mat,, or any other materials in specific locations on the tank wall. With this capability, we use the most efficient materials in the most efficient locations to meet the design requirements of the finished tank. Additionalwall thickness is added exactly where it is needed: Ribs are applied in optimal locations, made in the most efficient shapes, and constructed of the most efficient reinforcing materials. If a different rib shape or height or location would be better, the form or the location of the rib can be changed. If the rib form, shape was a part of the mandrel, these changes could not be made without changing the mandrel itself. Engineered and tested corrosion resistance The Fluid Containment tank wall is composed of resin, glass and a special treated silica that together result in a composite matrix that is compatible with petroleum products, including gasoline, jet fuel, av-gas, motor oil, kerosene, diesel fuel and fuel oil, and up to 100% ethanol and/or methanol blends and oxygenated motor fuels. Fluid Containment pioneered and perfected the use of a specially treated silica that is a part of our laminate matrix. The addition of this material has been proven to increase and improve the performance of our laminate in all fuels including alcohols. Our laminate has been thoroughly tested to meet the requirements of UL 1316. Additional long term corrosion testing continues at our Research and Development Center. This testing is done in conditions that match actual installation conditions. This results in data that can be used to accurately predict the long term properties needed for accurate tank designs. Data has been accumulated for current fuels and blends and it's effects on the laminate after a number of years. This data includes tests on current fuels and blends, and other oxygenates. We are constantly testing new, products that can be stored in our tanks in the future. Our R&D Center never stops asking questions. We could never maintain our position on the leading edge of fiberglass tank design without an uncompromising commitment to research and development. Our newly expanded R&D Center gives us the ability to look at new and promising ways to improve our products, expand our capabilities and better serve our customer's ever -changing needs. Our underground tank test pit helps us perfect our product. Fluid Containment is the only fiberglass tank manufacturer that studies tanks in all buried conditions and configurations. To do this, we constructed a full-scale test pit at our Conroe, Texas R&D Center, which allows us to test various tank designs with different backfill materials, anchoring methods, groundwater conditions, and many other variables. Products Our line of Type II Double - Wall Tanks is rustproof.. Fiberglass tanks simply will not rust — inside or out, on all four surfaces of the inner and outer tank. That's the reason Fluid Containment's fiberglass tanks have proven to be safe, cost-effective containment solutions for petroleum and related products. The fact is, after nearly 250.000 installations since the early 1960's, not a single leak has been attributed to internal orexter- nal corrosion. True Double -Wall construction means high; strength. We build strength and quality into everyIli ,' uble-wall tank from the beginning. ank inner and outer walls and specifi- cally designed ribs act together to form a.structural system that has earned the UL: 1316 listing that distinguishes this as a true double -wall tank. Secondary containment provides 360` of protection.'• You can count on total protection from our Double -Wall Tank: Our tanks are available with dry or wet monitoring of the annular space and will detect leaks in inner and outer walls under ail conditions. di 17 • Typical Gasoline System Overview (Model DWT 6) Standard Features: A. Flow Channels B. Tank Bottom Deflector Plates C. Primary Tank Fittings D. Monitoring Fitting Optional Accessories.. from Fluid Containment: 1. Turbine Enclosure 2. Fitting Kits for Turbine Enclosure 3. Secondary Containment Collar 4. Reservoir Sensor 5. Fiberglass Reservoir (replaces monitoring fitting) 6. Containment Collar Sensor 7. Monitoring Fluid with Color Tracer 8. Electronic Inventory Gauge 9. Electronic Control Panel 10. Split Strap Anchor System 11. Deadman Anchor Systems Optional Accessories from your Local Petroleum Distributor: 12. Dispenser 13. Dispenser Sump 14. Double -Wall Pipe 15. Submersible Pump 16. Fill Tube with Overfill Shut -Off Device 17. Ball Float Valve 18. Overfill Shut -Off Container 19. Primary Tank Vent Products Two wails mean twice the protection against costly Teaks. INNER TANK WA HIGH STRENGTH INTERIOR RIBS Our Double -Wall Tanks deliver state-of-the-art protection. FCI's advanced double -wall technology gives owners, municipalities, counties and states proven protection against petroleum contamination of underground water supplies. In addition to our UL listing, our tanks comply with the American; Petroleum Institute's recommendation for secondary containment systems wherever underground tanks are located within 300 feet of underground water supplies. As liabilities associatedwith leaking fuels soar, UL-listed fiberglass Type II Double -Wall Tanks for underground storage applications provide you with your best long-term protection. Don't settle for less than the ultimate in risk management. Type II Double -Wall Tanks give you two levels of protection, so you have twice the assur- ance and twice the risk management that any single -wall tank can offer. The primary tank is designed to contain, your fuel. In the unlikely event that there is a breach in this, wall, the secondary wall is designed to contain your product and prevent a spill into the environment. System testing assuresyou of product tightness. Continued assurance of the integrity of our Double -Wall Tanks can be determined by testing at the. jobsite — prior to and after installation — to prove the durability and product tightness of both the primary and secondary tanks: With some competitive tanks the secondary walls or jackets cannot be tested after the tanks have been', installed. Continuous monitoring and precision tank testing. capabilities are built in. • Because it is comforting to be able to test the ongoing integrity of any storage tank, FCI built into each of our double -wall tanks both continuous monitoring and precision tank testing capabilities. Our Type II Double -Wall Tanks provide a defined annular space to accom- modate virtually any type of monitoring method you choose —wet or dry. Our tanks can be supplied with a factory installed Hydrostatic Monitoring System with a brine monitoring fluid. The brine is a dark green color preinstalled in the interstitial space at the factory and used to perform visual leak testing during shipment and at the jobsite. We recommend the Hydrostatic Monitoring System because it offers a leak detection capability that is superior to other methods. It constantly monitors 100% of both the inner and outer walls under all installed conditions. Most steel tanks do not offer this feature. The Hydrostatic Monitoring System can also do double duty as a precision tank test which has been independently tested and validated to meet EPA requirements as a precision tank test, able to detect leaks as small as 0.1 gallons per hour. The precision tank testing procedure is easy to perform and consists of a few simple steps. • Typical Fuel -Oil System Overview (Model DWT 6) Standard Features: A. Flow Channels B. Tank Bottom Deflector Plates C. Primary Tank Fittings D. Monitoring Fitting Optional Accessories from Fluid Containment: 1. Turbine Enclosure 2. Fitting Kits for Turbine Enclosure 3. Secondary Containment Collar 4. Reservoir Sensor 5, Containment Collar Sensor 6. Monitoring Fluid with Color Tracer 7. Electronic Inventory Gauge 8. Electronic Control: Panel 9. Spiit Strap Anchor System 10. Deadman Anchor Systems Optional Accessories from your Local Petroleum Distributor: 11. Double -Wall Pipe 12. Fill Tube with Overfill Shut - Off Device 13. Overfill Spill Container 14. Foot Valve 15. Ball Float Valve 16. Primary Tank Vent Monitoring •al Conditions The reservoir liquid level wilt be stable if both the inner and puler tanks are tight. The reservoir sen- sor will activate an alarm if the reservoir drains or overfills. Inner Wall Breach Monitor fluid drains .into the primary tank causing the reservoir liquid level to drop and activate alarm. No petroleum product escapes n the primary contaminate the annular space. Outer Wall Breach Groundwater Below Tank Top If the groundwater is below the tank top, the monitor fluid drains into the ground, causing the reservoir liquid level to drop and activate the alarm. Outer Wall Breach Groundwater Over Tank Top If the groundwater is over the tank top, the reservoir will fill di up groundwater activate the high level alarm on the reservoir sensor. 0 CONCRETE TRAFFIC PAD -'. OPTIONAL RESERVOIR LIQUID LEVEL SENSOR i- STABLE RESERVOIR LIQUID LEVEL STORED PRODUCT' DOUBLE -WALL. UNDERGROUND TANK IMINIHENCEI v P. RESERVOIR DRAINS i— INNER WALL BREACH GROUNDWATER r LEVEL OUTER TANK BREACH lIt T GROUNDWATER LEVEL I <— RESERVOIR OVERFILLS ex OUTER TANK i! BREACH irk* Hydrostatic Monitoring System helps guard against', leaks and liabilities. Fluid: Containment recommends the Hydrostatic Monitoring',' System for Double -Wall Tanks because of its superior leak detection capability. By filling the cavity between the inner and outer tank walls with a non -hazardous liquid, hydrostatic pressure is continuously applied to both the primary and secondary tank. This system is capable of detecting tank leaks in either the primary or secondary tank walls for all installed conditions. The. Hydrostatic Monitoring System, with a stand pipe, can also serve the dual function of a precision tank 'test. The system has been independently tested and statistically validated to meet the EPA and National Fire Protection Association's criteria as a precision tank test. Using a stand pipe, the system has been shown to be capable of detecting leaks as small as 0.10 gallons per hour with a 99.9% probability of detection and less than a 1.2% probability of a false alarm. All the fiberglass Double -Wall Tanks in this brochure can include the optional fiberglass reservoir necessary for the Hydrostatic Monitoring System. The Hydrostatic Monitoring System provides continuous leak detection while avoiding false alarms caused by changes in product temperature, product level, tank deflection under loads, or groundwater conditions.' Accessories Antifreeze Mixtures In areas where ambient temperatures or delivered, products may besubjected to freezing conditions, an antifreeze solution must be used with our Hydrostatic Tank Monitor to avoidpotential tank damage. Brine Antifreeze Solution Our pre -mixed and blended calcium chloride solution provides freeze protection to -40°F. This non -toxic brine antifreeze can be factory -installed into tanks measuring up to 10' diameter and 30,000-gallon capacity. Its color tracer helps detect hidden damage from shipping or jobsite handling. Monitoring Monitoring System Configurations Our fiberglass Double -Wall Tanks are designed to accommodate wet (hydrostatic) or dry leak -monitoring systems. Wet Annular Space CONCRETE TRAFFIC PAD OPTIONAL RESERVOIR LIQUID LEVEL SENSOR F- LIQUIO LEVEL TABLE RVOIH STORED PRODUCT DOUBLE -WALL UNDERGROUND TANK Dry Annular Space Fluid Containment provides a factory -installed "drawstring" at the annular space monitoring fitting, to assist in positioning liquid sensors at the bottom of the annular space. If your tank is ordered with a dry annular space, but fitted with the optional fiberglass reservoir (instead of a monitoring fitting), the drawstring will be positioned within the reservoir. Hydrostatic Monitoring System 1. Use antifreeze (brine) solution in cold climates. 2. Maximum burial depth from tank top is seven feet below grade. 3. Monitoring cavity must be, vented to the atmosphere. The optional reservoir sensor includes vent holes to vent the monitoring cavity. 4. After installation, set the liquid level in the reservoir so reservoir is half full. CONCRETE TRAFFIC PAD --. 44-- RISER PIPE �-- 4' ANNULAR SPACE FITTING T1/4_ LIOU D SENSNG PROBE CONCRETE TRAFFIC PAD -+ ,RISER -.- PIPE , VACUUM OR AIR PRESSURE SENSOR t- 4' ANNULAR SPACE FITTING CONCRETE AFFIC PAD -4- RISER PIPE -. 4' ANNULAR SPACE FITTING HYDROCARBON VAPOR SENSOR WATER SENSOR Monitoring System with Liquid Sensor Typical configuration for an electronic sensor or manual dipstick. 1. Use the standard monitoring fitting 2. Monitoring cavity can be vented or sealed. Monitoring System with Vacuum and Air Pressure 1. Use the standard monitoring fitting. 2. Maximum continuous positive air pressure is 3 psi. 3. Maximum continuous vacuum is 5 psi. Monitoring System with Gasoline Vapor Sensor Many vapor sensors also include a water sensor. 1. Use the standard monitoring fitting. 2. Monitoring cavity can be vented or sealed. The Hydrostatic Monitoring System is the best at leak detection because it's continuously monitoring the' complete ihner and outer tank, Monitors outer wall totally Leak Detection Performance Alternative Monitoring Systems: A Performance Comparison Fluid Liquid Vacuum Containment Inc: Sensors In Or Air Gasoline Hydrostatic Dry Annular Pressure Vapor Tank Monitor Space Monitors Sensors Meets EPA criteria as a precision tank test Yes No No No, Monitors inner wall totally Yes No(1)(0 Large Leaks Yes Onlym Yes No( Prevents, product from escaping into the Yes annular space with an inner wall leak Proven In Use Leak detection performance independently Yes tested and statistically validated Optional electronic equipment tested and Yes labeled by Underwriters Laboratories Long-term proven performance of Yes tank monitor Design Awards Winner of National Safety Council Yes Award for achievements in product safety Nom Large Leaks No(s11aJ(n Only(4)(3) No(31 No,,, Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Footnotes: (1) Only monitors the portion of the inner wall which is in contact with liquid product. (2) Only monitors the portion of the outer,wall which is submerged in groundwater. (3) With an inner wall leak, product can leak to the outer wall. Then if the outer tank has an unknown leak; product will spill. (4) The vacuum or pressure pump can mask small leaks in the inner and/or outer tank wall This pump is normally required to compensate for pressure and vacuum losses caused by line losses or changes in product temperatures. (5) Does not monitor any portion ofthe outer wall. (6) If the outer wall has a larger leak than the inner wall, product may spill without accumulating in the annulanspace. (7) If the annular space is contaminated with product, residual fumes are difficult to remove. Electronics Fluid Containment monitoring and inventory control components can be configured to satisfy a wide range of customer requirements. Optional Fluid Containment components —control and switch panels, sensors, probes and gauges —are available for all double -wall, single -wall, compartment and oil/water separator tanks as well as for single or multiple tank installations. Standard Tank Notes. 1. The primary tank's standard pipe fittings are 4" NPT half couplings. All tanks include one manway with three or more primary tank fittings in the cover. All other primary tank fittings are mounted on the tank. Additional manways and tank fittings are available on a made -to -order basis. 2. Tank bottom deflector plates are standard under every manway and fitting. 3. An optional fiberglass reservoir for leak monitoring can be integrally bonded to the top of all 6'-diameter and larger Double -Wall Tanks. It includes a 4" NPT half -coupling fit- ting mounted on top of the reservoir, which allows access to the cavity between the inner and outer tank walls.. On 6' diameter and larger tanks with an optional fiberglass reservoir, the reservoir is positioned over the normal monitor fitting position and the tank will not include a separatemonitoring fitting. The rib under the reservoir is hollow if. the annular space is not factory filled withmonitoring liquid. 4. For all double -wall tanks without'a reservoir, a 4" NPT annular space fitting is included on the top of the tank for monitoring. It permits access to a hollow rib which accommodates the installation of liquid sensors. 5. Fiberglass reservoirs are not included on 4' diameter tanks. A contractor -supplied 4" diameter riser pipe must be inserted into the 4" diameter annular space fitting to serve as the'tank's reservoir. This riser pipe must be at least 2" longer than the electronic sensor. 6. All primary tanks must be vented. They are intended to be operated with fluid levels no higher than the tank top. Fiberglass tanks are designed to be operated at atmospheric pressure only — except, when using vapor -recovery systems — provided the pressure or vacuum does not exceed 1 psi on the primary tank. Over -pressurizing the primary tank will result in tank failure. When venting the monitoring cavity between the inner and outer tank, it must be vented independently from the primary tank (annular space venting is required for all hydrostatically monitored tanks). See pages 14-22 for standard tank data and configuration. Tank Model:DWT 6 Type II Standard Tanks No. of Na. of 4" NPT 4" NPT Tank Nominal Actual Overall Nominal Nominal Wt. Manway Tank Diameter Capacity Capacity Length Weight w/Brine Fittings .Fittings No. of (o No. of Down Straps Lift Lugs Requ6e,'d,, 4 550 543 6'7" 690 895 5 i N/A 1 4' 600 606 T 3" 750 975 4 1 1 4' 1,000 966 11' 1 " 950 1,235 4 1 1 6' 2,500 2,689 13' 9" 2,060 2,660 5 1 2 6' 3,000 3,323 16' 9" 2,475 3,200 4 2 1 6' 4,000 3,958 19' 9" 2,700 3,500 3 3 1 6' 5,000 5,068 25' 0" 3,050 4,000 3 3 2 6' 6,000 6,179 30'3" 3,400 4,500. 3 - 3 2 5,000 4,947 16'9" 2,850 3,750 8' 6,000 5,897 19' 6" 3,400 4,500 8,000 7,796 25' 0" 4,200 5,600 3 3 °'2 8' 10,000 9,696 30'6" 5,000 6,700 3 3 2 8' 12,000 11,595 36'0" 6,000 8,000 : 3 15,000 14,545 44' 6-1/2" 7,500. 10,000 3 3 %2.: 10' 10,000 10,257 20' 11-1/2" 5,950 7,900 10' 12,000 11,873 23' 8-1/2" 6,600 9,000 4 2 r4 10' 15,000. 15,104 29' 2-1/2" 8,000 11,500 3 3 10' 20,000 19,951 37' 5-1/2" 9,900 14,500 3 3 4 10' 25,0001' 24,970 46' 0" 11,700 17,500 3 3 4 8 10' 30,000. 29,816 54'3" 13,900 21,000 10' 35,000 34,835 62' 9-1/2" 17,000 N/A 40,000 39,854 71'4" 18,500 N/A Made to order (1) If brine filled, 8 lift lugs installed. cL DWT-6 Type I -550 OPTIONAL 42", CONTAINMENT COLLAR 22"MANWAY W/ (5) 4 NPT FITTINGS / 8"R ' 4" ANNULAR SPACE FTG 4" ANNULAR SPACE FTG 4'0' 1.0 4'3 0.0 4'3 0.0 2'-1/2" 6' 1/2° 24-1/4" 3' 37/16' 4 /8' 24 /4' 3' 3 7/16'--4 DWT-6 Type II ,000 ONAL 42" CONTAINMENT COLLAR 22" MANWAY W/ (4) - 4° NPT FITTINGS , 4" ANNULAR SPACE FTG. '-- 4' NPT FTG. ti Still, 341/4' I 2'2-1/4 ! 2'2-1/4' 3'41/4' .-4'2' 4'2• 5'6 7/16' 5'6-7/16' 4' Diameter DWT-6 Type OPTIONAL 42" CONTAINMENT COLLAR 22' MANWAY W/ (4) - 4' NPT FITTINGS 4' NPT FTG. 4r Vol 4' ANNULAR SPACE FTG. 4'0' 1.0 4'3 0.D. 2'1-3/4 3'3/4' 1'1-1/6 i 61/2' 1111'11 283/8' —0-4— '2'6 4/4' 23/8'-4 1 3'7 7/ 6' 1 3'7.7/16' 8" R 15 6' Diameter 22' MANWAY W/ (4) - 4' NPT FITTINGS 6'3-1/2' O.D DWT-6 Type 11 ,000 OPTIONAL 42" CONTAINMENT COLLAR 4 4" NPT FTGS. (3 TYP) •' OPTIONAL RESERVOIR 4' ANNULAR SPACE FTG. 12'8 22' MANWAY W/ (3) 4' NPT FITTINGS DWT-6 Type II , 00 22' MANWAY W/ (5) - 4" NPT FITTINGS DWT-6 Type II (6 OPTIONAL 42" CONTAINMENT COLLAR 8' R 4" NPT FTG, If' OPTIONAL RESERVOIR 4' ANNULAR SPACE FTG. \ _ i OPTIONAL 42' CONTAINMENT COLLAR ✓ 8' R j 4' NPT FIG. (TYP. 3) ✓ I •,' OPTIONAL RESERVOIR 4' ANNULAR SPACE FTG. cc- DWT 6 Type ,000 OPTIONAL 42' CONTAINMENT COLLAR 22' MANWAY W/ (3) - 4' NPT FITTINGS �, ., 8'R 4' NPT FTGS.(3 TYP.) I?4 * I•,' OPTIONAL RESERVOIR (ANNULAR SPACE FTG. I + I 22' MANWAY W/ (3) - 4' NPT FITTINGS. 6'0' 10 6'3-1/2 0.0 DWT-6Tyy (6)-6,000 OPTIONAL 42' CONTAINMENT COLLAR 8 R 33-1/2'-0- 6' Diameter 4' NPT FTG. (TYP. 3) V _ 1®`' OPTIONA RESERVOIR (ANNULAR PACE FTG. 1. 2'0-1/2' 2 3 4 5 6 7 8 9'7 1/2' n_, ■ 9 101 1213 14 15 i617 18 17' 76-1/2'TYP. 6'11' 9'712' 30'3' 17 8' Diameter DWT6Type ,000 22' MANWAY w/ (4) - 4" NPT FITTINGS 8'0 0.D. 3'3-7/8' 22'MANWAY W/ (5) - 4' NPT FITTINGS - 1 8'0 0.0 DWT-6 Type II 3'3-7/8'+ OPTIONAL 42' CONTAINMENT COLLAR 4' NPT FTG. (TYP. 2) OPTIONAL RESERVOIR 4' ANNULAR SPACE FTG. 1y�1 1 '10.1/4' 19'6' 22' MANWAY W/ (3) -4' NPT FITTINGS„ 8'0 O.D. 6-12' TYR OPTIONAL 42' CONTAINMENT COLLAR 8' R 4' NPT FTG. • • OPTIONAL RESERVOIR 4' ANNULAR SPACE FTG. 1 11/8' 6-1/2' TYP. 1 '1-1/ 16'9' DINT-6 Type II (8)-8 OPTIO 4242' CONTAINMENT .� g• R f 4' NPT FTC. (TYP. 3) I• OPTIONAL RESERVOIR 4' ANNULAR SPACE FTG. I/8' -1- '10.1/4' 6'10.12' -.4- '7-1/4' I 6'10 1/2• -. 3'3-7/8' 25'0' 18 22' MANWAY W/ (3) - 4' NPT FITTINGS 8'0' 0.0 8'0 w3'3-7/8'+ 22' MANWAY W/ (3) - 4' NPT FITTINGS G0. DWT-6 Type II (8)-1 OPTIONAL 42' CTAINMENT COLLAR !e 0 8' R ✓ 4' NPT FTG. (TYP. 3)' tit * 1_• OPTIONALRESERVOIR 4' ANNULAR.SPACEFTG. 4- 3B-3/4' 8' Diameter 8 9 10 11 12 13 14 15 16 11-Ire' 11.1i6-12'TYP. 7'4 1l ' 8'3' 3'3 7/8'-> 30'6' DWT-6 Type II (8)-1 OPTIONAL 42' CONTAINMENT COLLAR w 31-7/8'+ 11'0' 22' MANWAY W/ (3) - 4' NPT FITTINGS 7'8° I. 8'0 0D. 2 3 4' NPT FTG. (TYP. 3) OPTIONAL RESERVOIR 4' ANNULAR SPACE FTG. d -I 38-3/4' f 7'4-1/4' 36'0' DWT-6Type II - 5,000 /OPTIONAL 42' CONTAINMENT COLLAR 8'R 4 5 6 7 8 9 10 x-33'-4- n_ 11 12 13 14 4' NPT FTG. (3TYP.) 15 6 17 -1/8 « 0- 15' 3' -4- 3'3-7/8' -- 9' 7 1/2' 5' 10 /8' 14' 0 1/2' 6'1012' 44' 6-1/2' I0 18 19 • 11/8 6-1/2'TYP. I 41 `' OPTIC AL RESERVOIR 4' ANNULAR SPACE FTG 20 21 22 n 23 24 25 15' 3'. 5' 05/8' �. 9'7 tit' 3' 3-7/B' 19 10' Diameter 22' MANWAY W/ (5) - 4' NPT FITTINGS OB. 10'6 DWT-6 Type II 11 2,000 22' MANWAY W/ (4) - 4' NPT FITTINGS DWT-6 Type II (10)-1 OPTIONAL 42' CONTAINMENT. COLLAR 6 R 4' TOP MTD: FTG. OPTIONAL RESERVOIR 4' ANNULAR SPACE FTG. la's 0 5'6-1/4'-. 5'9-12' —. 4'1-1/4'-. OPTIONAL 42' CONTAINMENT COLLAR if 8 R 4' TOP MTD. FIG. (TYP. 2) OPTIONAL RESERVOIR 4' ANNULAR SPACE FTG 20'11 12' 6-12' TYP. 5'6-1/4'-. 20 22"MANWAY W/ (3) - 4" NPT FITTINGS DWT-6 Type II (10 5,000 OPTIONAL 42' CONTAINMENT COLLAR r 8'R 10'0' I.O. 10'6 O.D. 5'6-114' IJ2 3 4 8 3" 5' 6 4' NPT. FTG. (TYP. 3) 1•� OPTIONAL RESERVOIR 4' ANNULAR SPACE FTG . n I n .-.ire 36.1/7 22"MANWAY W/ (3) - 4' NPT FITTINGS F 10'0° I.O. 10'6 0.0. 5'6-1 /4° —. 2 5'6' 10 - 1'8' 29'2 1/2' 7 8 9 10 8'3' 12 16 1/2"TYR' 5'6 1/4" -÷ DWT-6 Type II 20,000 :OPTIONAL 42" CONTAINMENT COLLAR 4' 5 6, 7 8 9 10' TT.Tc_ 610-1/2 1 8' 41-1/2 37;51/2' 4' NPT. FTG. (TYP. 3) 1 0 1 10' Diameter • i;° OPTIONAL RESERVOIR 4" ANNULAR SPACE FTG. —1 ' 15 6 17 18 6-12'TYP. 5'61/4'—. '71 10' Diameter - 22' MANWAY W/ (3) 4' NPT FITTINGS 10'0' I.D. 10'6" 0.0. 2 3 4 DWT-6 Type II (1 s ,000 OPTIONAL 42" CONTAINMENT COLLAR 6' R 5'6-1/4'-.-.-- 5'6'—» 22' MANWAY w/3 -4" NPT FIGS, 10'0 I 5 6 7 8. 9 1 -4---- 6'101/2' —� OPTIONAL 42' CONTAINMENT C !' 8'R w 5'6-1/4'-. 8'3' 4' NPT. FTG. (TYP. 3) 10 11 12 10' «1 8' 8 3 14 10 DWT--6 Type II (10)-30,000 29' 8'6 /2' 4'1 1/2' 4' 3' OPTIONAL R-40 RESERVOIR 4' ANNULAR SPACE FTG . I OPTIONAL R-40 RESERVOIR ' ANNULAR SPACE FIG. F 18 19 8'6 1/2' Made -to -Order Double -Wall Tanks Suggested Fitting Locations Although our standard Double -Wall Tanks are designed to •accommodate most storage applications, they can be modified to' include additional manways, tank -mounted fittings or other Double -Wall Tank accessories. Made -to -order tanks require additional lead time for production and are more expensive to purchase. The standard tanks are shown with tank -mounted fittings in the standard, positions. Monitoring fittings, reservoirs, lift lug locations, and anchoring strap locations can sometimes be relocated, but require special approval prior to any relocation. In addition to the standard tank notes the following notes apply: 1 The location of additional and/or modified tankaccessories should be referenced by the numbered fitting position between the ribs. 2. The primary tank's standard pipe fittings are 4" NPT half couplings. All tanks require at least one manway. The manway cover should include at least one fitting to facilitate future volumetric tank testing. 3. Specifying more or larger manways than available on standard tanks may alter the anchoring strap locations. These can often be relocated, but require special approval prior to any relocation. Larger manways also require larger containment collars: 4. We recommend that all additional manway covers include at least one fitting to facilitate future volumetric precision tank testing. 5. Tank bottom deflector plates are standard under every manway and fitting. 6. Monitoring fittings, reservoirs and lift lug locationscan sometimes be relocated, but require special approval prior to any relocation. SECONDARY CONTAINMENT COLLAR 1 MANWAY CONTAINMENT COLLAR SENSOR Fiberglass Secondary Containment Collar Containment Collars Optional tank accessories for secondary containment systems. Fiberglass Secondary Containment Collar An optional secondary containmentcollar provides a containment area for spilled liquids, as well as a location for the leak -monitoring sensor., Collars can be installed around other tank fittings and accessories, where. space permits. Collars are constructed of fiberglass and are available in 42" diameter (with 22" manways) and 48" diameter (with 22" and 30" manways). The secondary containment collar is integrally attached to the tank top to provide a watertight seal. The collar is factory, installed and tested prior to shipment. Another collar leak test should be performed at the jobsite by the installing contractor. See Fluid Containment installation instructions for details. The secondary containment collar must periodically be tested for leaks -- at least once each year or after collar maintenance is performed — by adding water to the collar above the tank top. The sec'.' ondary containment collar must be continuously monitored with an electronic sensor. for potential spills or piping leaks. STANDARD 4" NTP PRIMARY PIPE TANK MOUNTED \ FITTING SECONDARY 6' SECONDARY �\ A.---"FRP PIPE CONTAINMENT\ Y FITTING > �' Secondary Containment for Fittings Secondary Containment Fitting A 6" FRP threaded secondary coupling is concentrically positioned around the 4" NPT primary -tank fitting. The secondary containment coupling is surface -mounted onto the tank and does not penetrate the outer wall. There is no access to the tank annular space at the 6" secondary containment coupling. To directly monitor the cavity between the primary and secondary pipe a fitting with an ;access, port should be installed. i ASPHYXIATION EXPLOSION FIRE Turbine Enclosures Fiberglass Turbine, Enclosures provide access to critical equipment and serve as la termination point for piping. Our turbine enclosures are fiberglass — a proven material for long-term performance. Compared to other unreinforced plastics and HDPE products, the rigid fiberglass construction minimizes deformation during backfilling,'to help assure liquid -tight seals at fitting penetrations. Turbine enclosures must be mounted on top of a secondary containment. collar. Primary piping is installed from the submersible pump to the dispenser. When the double -wall piping is installed over the primary piping, the double -wall pipe connects to the turbine enclosure using' optional fittings, available from FCI or your petroleum equipment distributor. In the event of an accidental spill from the primary piping, the spilled product will drain into the turbine enclosure and accumulate in the secondary containment collar. The secondary containment collar serves as a basin to allow early detection of leaks of the submersible pump or the product piping. When there is concern about the ingress of water at the collar/turbine enclosure seam, the turbine enclosure should be sealed to the secondary containment collar at the jobsite. Fluid Containment provides an alcohol compatible adhesive kit to make this connection. Continuous electronic monitoring of the secondary containment collarshould be used to warn the operator of the accumulation of petroleum product, before the liquid level rises above the collar/turbine enclosure seam. Turbine enclosures are available in 42" and 48" diameters with a minimum 2' length. To accommodate deeper burial depths, longer turbine enclosures are available in 1' increments. The turbine enclosure can be trimmed at the jobsite to adjust for the final burial depth. Note: For high groundwater conditions at or above subgrade,, a sealable or watertight turbine enclosure should be used to prevent water infiltration. When a tank will be equipped with more than one turbine enclosure or manway riser, the tank may require special installation (deeper burial, additional anchor straps, etc.). Contact Tank Technical Support for specific installation details. Warning: a turbine enclosure constitutes a confined space. Never enter a turbine enclosure without proper training and OSHA -approved equipment. Turbine Enclosures Turbine Enclosures Turbine enclosures are available in three models - Non -Sealed (NTE), Watertight (WTE), and Sealed (STE). For all models, the turbine enclosure body is mounted on the tank collar. If a leakproof joint is required, cement the enclosure body to the tank collar using, the adhesive ,(Kit AD). (It is recommended that the joint always be cemented). All turbine enclosures are supplied with 'adhesive kits. A minimum 36" diameter street box is required with all FRP models toallow the, removal of the FRP lid after the turbine enclosureis installed. This also allows the removal of the' manway cover. To leak test the turbine enclosure, use a standing water test. DO NOT use an air pressure test. SEPARATOR MATERIAL (48" X 48' X 2") FPR REDUCER TURBINE'.:. ENCLOSURE BODY FIELD rIA-SEALED JOINT CONTAINMENT COLLAR 'TANK WALL Non -Sealed FRP Turbine Enclosure Non -Sealed FRP Turbine Enclosure (NTE) Friction fit lid to repel water from. above The Non -Sealed FRP Turbine Enclosure includes an FRP enclosure body (variable length in 12" increments, 42"'or. 48" ID's), an FRP reducer (42"x30"'or 48"x30" ID's), and'. a loose fit FRP lid (32.5" OD) with handle. The enclosure'' body is field cemented to the tank collar using the supplied adhesive kit (Kit AD). The reducer and the lid fit over the enclosure body with a'loose fit. The 30" open- ingallows for the removal of a 22" manway lid (28" OD). Model Length (L) NTE42-2 WTE42-2 STE42B-2 I2' NTE42-3 WTE42-3 STE42B-3 3' NTE42-4 WTE42.4 STE42B-4 4' NTE42-5 WTE42-5 STE42B-5 5' NTE42-6 WTE42-6 STE42B-6 ' 6' NTE48-2 WTE48-2 STE48B-2 NTE48-3 WTE48-3 STE48B-3 3' NTE48-4 WTE48-4 STE488-4 4' NTE48-5 WTE48-5 STE48B-5 ' 5' NTE48-6 WTE48-6 STE48B-6 �jl Turbine Enclosures Watertight FRP Turbine Enclosure (WTE) Suitable for moderately high groundwater The Watertight FRP Turbine Enclosure includes an FRP enclosure body (variable length in 12" increments, 42" or 48" ID), an FRP reducer (42" 30" or 48" 30" ID's) with o-ring groove and'o-ring gasket, and a push on FRP lid (32.5" OD) with 2 handles. The enclosure body is field cemented to the tank collar and the reducer is field cemented to the enclosure body using the supplied adhesive kits (Kit 'AD, 2 kits required). The reducer/enclosure body joint is on the exterior of the enclosure body allowing easy field installation of the adhesive without entering the enclosure. The lid compresses the lubricated o-ring when it is pushed onto the reducer top providing a watertight seal with water up to 12" over the lid. The lid can be pushed into position by standing on the lid which is made with a non-skid exterior surface. The lid includes two handles. One is offset to aid in the removal of the lid and the other is centered on the lid. The 30" opening allows for the removal of a 22" manway lid (28" OD). The enclosure must be vented at all times (usually accomplished with the double wall piping). Sealed FRP Turbine Enclosure (STE) Suitable for extremely high groundwater conditions The Sealed FRP Turbine Enclosure includes an FRP enclosure body (variable length in 12" increments, 42" or 48" ID's), an FRP reducer (42", or 48" ID's) with an oval. flanged manway (23" 29" ID's), a flat gasket, SS bolts with non -galling silicone -bronze nuts (optional bolt rings can be supplied to replace the bolts), and an oval FRP lid with handle. The enclosure body is field cemented to the tank collar and the reducer is field cemented to the enclosure body using the optional adhesive kits (Kit AD, 2 kits required). •1__ ate! ia Oa Silt FIELD L SEALED JOINT 4 NMI ,,,,,.,,n 51/2 SEPARATOR MATERIAL (48' X 48" X 2"). • lllN) •" .. '. Z. FPR REDUCER TURBINE ENCLOSURE BODY O FIELD JOINT CONTAINMENT COLLAR Watertight FRP Turbine Enclosure SEPARATOR MATERIAL (48° X 48' X 2°) TANK WALL w t/2• FRP REDUCER ENCLOSURE TURBINE ENCLOSURE BODY FIELD SEALED JOINT TANK WALL CONTAINMENT /. COLLAR Sealed FRP Turbine Enclosure The lid is bolted to the manway with 14 bolts providing a watertight seal with water up to 7' over the lid. The lid can be supplied with an optional 6" NPT fitting with plug which can be used as an observation port. The oval manway allows for the removal of a 22" manway lid (28" OD). The enclosure must be vented at all times (usually accomplished with the double wall piping). 27 r TURBINE ENCLOSURE WALL/INTERIOR FEMALE ADHESIVE SECTIONMALE SECTION FRP Coupling Kit (for 3" or 4" OD FRP pipe only) MANWAY ON 8', 8', 810' DIAMETER TANKS ONLY iH �r 4" RUNG YR) 3/8' -8- 1 4 f f2"TYP. t FRP UNIVE MOUNTING LUG Tank Ladder Flexible Entry Boot FRP SLIP LNG Accessories Field -installed piping and electrical fittings Secondary pipe fittings can be field -installed using one of our optional two-piece FRP couplings. When used for piping connections, the FRP coupling is designed to provide secondary containment connections only to the turbine enclosure. Do not use the FRP coupling for primary piping connections to the turbine enclosure. FRP Coupling Kit (3" or 4") A two-piece field -installed 3" or 4" FRP coupling can be cemented in the turbine enclosure to provide a watertight seal for piping penetrations in high groundwater environments. The FRP coupling is a two-piece fitting which is cemented to the turbine enclosure. The FRP coupling's male and female sections are threaded together to hold the fitting in place while the adhesive cures. Each kit (Kit FC-3 or FC-4) includes the adhesive and mixing instructions. Flexible Entry Boot FEB Flexible Entry Boots are rubber compression type boots installed into the wall of the turbine enclosure to seal all pipe and conduit entries. These boots are designed to permit up to a 300 angle of flexibility for entries. This flexibility is important for aligning pipe connections or as a stress relief for the pipe during backfilling and ground movement. The Flexible Entry Boot is available for standard 3" and 4" secondary piping and 3/4" conduit lines. Tank Ladders Our optional tank ladders are available in either carbon steel, aluminum, or stainless steel. These ladders are shipped along with the tank and field attached to the tank bottom with FRP mounting lugs. Ladders are retained at the top with FRP slip lugs on the trunk of the manway to allow for the vertical contraction and expansion of metal ladders. (Manway and ladder are sold separately.) Tank ladders are not recommended on 4' diameter tank capacities. Because of limited space, the ladders interfere with tank entry. Probe Drawstring On tanks with a dry annular space, we provide a factory -installed'. "draw- string" at the annular space monitoring fitting, to assist in positioning liquid, sensors at the bottom of the annular space. Anchoring Systems Deadmen/Turnbuckles Fluid Containment can provide deadmen anchors and turnbuckles for selected models of double wall tanks. Deadmen anchors provide a means to prevent, installed fiberglass tanks from floating out of the ground when the tank installation is subject to ground water around the tank. Deadmen anchors, when. used with FCI fiberglass hold down straps and other FCI or contractor', supplied hardware and installed according to FCI installation instructions, prevent tank flotationand cost less than a concrete pad under the tank. The FCI deadmen and turnbuckles can usually be shipped with 4', 6' and 8' tanks at no additional charge. Deadmen are available in various lengths and are designed with and without eyebolts. Ask for publication "Deadmen Anchors and Turnbuckles" to select the proper deadman for a particular tank size. Split Strap Anchor System Fluid. Containment can provide a split strap anchor system for 6', 8' and 10' diameter double wall tanks. The split strap anchor system provides a method to attach and tighten the tank anchor straps to deadmen or to an anchor pad without entry into the excavation. The split strap anchor system is safer and less costly than traditional methods that require shoring or other hole stabilization techniques to allow entry into the excavation. Fiberglass Anchoring Straps When mechanical anchoring is specified, fiberglass anchoring straps are available for all Double -Wall Tanks. WIRE ROPE TRIPL E CLAMP DOUBLE H \4C.q� TANK STRAP EYELET / SEE DETAIL A WALL I( OPTIONAL `/ TURNBUCKLE ICI yASSEMBLY SIC: nk DEAD MAN ANCHOR SYSTEM FRP STRAP 12' MINIMUM BACKFILL 8E0 ANCHOR PAD SYSTEM TANK ENO VIEW STRAP EYELET GALVANIZED STEEL Fiberglass Anchoring Straps FIBERGLASS STRAP DI STRAP EYELET DETAIL A Tank Diameter Nominal H D E F G 4' 21" 9/16" 1 3/8" 11/8" 21/16" 6' 34" 11/8' 27/8" 2 1/2" 41/4" 8' 38" 1 1 /8" 2 7/8" 2 1 /2" 4 1 /4' 10' 52" 1 1/8" 2 7/8" 21/2" 41/4' Deadmen edge��o-o Split Strap Anchor System Tank No of Straps Capacity Diameter Required 550 4' 2 600 4' 2 1,000 4' 2 2,500 6' 2 3,000 6' 2 4,000 6' 2 5,000 6' 4 6,000 6' 14 5,000 8' 2 6,000 8' 2 8,000 8'. '.4 10,000 8'. 4 12,000 8' 4 15,000 8' .6 10,000 10' 3 12,000 10' 4 15,000 10' 4 20,000 10' 6 25,000 10' 8 30,000 10' 8 35,000 - 10' 8 40,000 10' 10 NPT Tank -Mounted Fittings Plate Gusseted Nozzles Stainless Steel Bolt Ring These fittings let you configure our tanks to your Tank Fittings needs. NPT Tank -Mounted Fittings The standard tank -mounted fitting is 4" NPT half coupling. The tank -mounted fittings to the primary tank are placed on the top center line of the tank. Plate Gusseted Nozzles Fiberglass plate gusseted nozzles are available in 2", 3", 4", 6", 8", 10", 12", 14", 16" and 18" diameters and are installed on the top center line of the tank. Fiberglass Manways Standard fiberglass manways are 22" diameter. Optional 30" and 36" manways are available. The standard 22" manway has a maximum load -bearing capacity of 2,400 lbs. Each comes with a painted carbon steel cover, a gasket, 24 zinc -coated 1/2" x 1-1/2" bolts and nuts. Fittings in manway lids are 4" steel NPT half couplings. Warning: an underground tank constitutes a confined space. Never enter a tank without proper training and OSHA -approved equipment. 'I iii r i ASPHYXIATION EXPLOSION FIRE NOTE: the use of manways Is not intended to encourage tank entry, which can pose a safety hazard for unqualified mechanics, especially after product has been stored in the tank. All fiberglass, Double -Wall Tanks -include one manway. Some of the primary tank fittings are clustered in the manway cover to facilitate secondary containment of the pump and piping. Stainless Steel Bolt Rings Fluid Containment can provide a Stainless Steel Bolt Ring for use with fiberglass manways and sealed turbine enclosures on double wall tanks. The Bolt Ring is manufactured in two halves and provides a flexible semi -circle of bolts that will stay in position in a flange and allow the nuts to be tightened without the use of a wrench to keep the bolt from turning. The Bolt Ring is manufactured of 304 or 316 stainless steel with non -galling silicone bronze nuts, providing improved corrosion resistance over,plated bolts, nuts and washers. Optional Manway Covers in Stock Note: 1. All fittings are standard 4" NPT steel. Typical fitting configurations are available from our Inside Sales Group. 2. All manway covers should include at • least one fitting to facilitate future volumetric precision tank testing. Bolt.Hole Configurations Manway Size 22" 30' 36" Bolt Size 1/2' x 1-1/2"L 5/8" x 2.1/2"L 5/8° x 3-1/21 No. of Bolts 24 30 32 BCD 25-5/16" 35-1/8"42-3/4" Cover Diameter 28" 38' 46" Made -to -Order Covers Made -to -order covers with various fitting placements are available. Please provide us with a detailed drawing of the fitting configuration you require. .} Fiberglass Manway Extensions Tank entry in high groundwater conditions and/or deep burials may require the use of manway extensions. When properly bolted to a tank -mounted manway, the manway extension will provide a watertight access route to the tank Interior. Fiberglass manway extensions of 22", 30" and 36" diameters are available in 2' lengths. Each manway extension includes a gasket and set of nuts, bolts and washers: Fiberglass Manway Riser The optional fiberglass manway riser provides a non -corroding passage from a manhole box and cover (traffic areas require reinforced concrete road surface) down to the tank manway: The manway riser is available in 30" thru 54" lengths in 6" incre- ments. It consists of a 48" diameter tube, open at one end, partially closed on the other end with a 22-1/2" centered square hole with rounded corners. If buoyant conditions can exist and the tank has more than one manway riser, contact Tank Technical Service for proper tank anchoring recommendations for the installation. Accessories Stock Manway Covers — Fitting Configurations Radius No. of From Manway Fitting Fittings Cover Size Pattern (4' NPT) Center Spacing Model 22° A 1 Center — M221-0 B 2 8" — M222-A G 3 8' — M223-8A D 3 8' 90° M223-8T E. 3 8" 120 M223- F 4 8" 90° M224.8 G 5 8° 90° M225-8 30' A 1 Center — M301.0 B 2 12" — M302-12A C 3 12" — M303.12A D 3 12" 90° M303-12T E 3 12" 120° M303-12 F. 4 12" 90° M304-12 G 5 12" 90° M305-12 36' A 1 Center — M361-0 B 2 15" — " M362-15A C 3 15" — M363-15A D 3 15" 90° M363-15T E 3 15" 120°' M363-15 F 4 15"_ 90° M364-15 G 5 15" 90° M365-15. CONCRETE PAD \ y MANWAY EXTENSION 2 Fiberglass Manway Extension Reinforced Concrete #5 Rebar 6" on Center Bath Ways (2 layers) 42' Standard A Notes: • 1. Riser is not load bearing 2. Rebar mat must extend 4' in all directions from center of riser TYPICAL RUING CONFIGURATIONS 24" X 24' Manhole Box with Cover (not supplied) 48'ID 4— Riser 22' Manway t'li %or 22 1/2" Sq. .-->• (opening in rise ) Fiberglass. Manway Riser A 4 2' x 4' x 4'0' Min. or Equivalent Wood Required to Support Rise AA Tank Length Fluid Containment Warranty and Installation Information for Standard Double -Wall Tanks. WARRANTY Double -Wall Underground Petroleum Storage Tank .,d Containment, Inc. ("F.C.I") warrants to the ("Owner") that F.C.I's new manufac- tured double -wall underground tanks (and: secondary containment collars and all tur- bine enclosure parts made of FRP if attached) will meet F.C.I:s published specifica- tions and will be free from material defects in materials and workmanship for a period of one (1) year following date of original delivery by F.C.I. to Owner. F.C.I: further war- rants that if said tank(s) (and collar(s)) are installed, operated and maintained in accor- dance with our instructions and applicable state and federal regulatory requirements, said tank(s) (and collar(s)): I. Will not leak for a period of thirty (30) years from date of original purchase due to natural external corrosion; and II. Will not leak for a period of thirty (30) years from date of original purchase due to internal corrosion, provided the tank is used solely (with or without tank water bot- toms) to store the following products: A. The following petroleum products: gasoline,'jet fuel, av-gas, motor oil (new or used), kerosene, diesel fuel or fuel oil, at temperature not to exceed 150°F. B. Alcohol -gasoline blend motor fuels. 1. Ethanol blends • Gasohol (90% gasoline and 10% ethyl alcohol). 2. Methanol blends • Oxino1-50" waiver (90.5% gasoline and 9.5% Oxino1-50" composed of a mixture of 4.75% methanol and 4.75% GTBA). • DuPont EPA waiver (gasoline with 5% methanol and a minimum of 2.5% cosolvent. The blend may contain a maximum concentration of up to 3.7 weight percent oxygen in the final fuel). C. Oxygenated motor fuels. • Gasoline with up to 20% (by volume) of methyl tertiary butyl ether (MTBE), ethyl tertiary butyl ether (ETBE)', tertiary butyl alcohol (TBA), tertiary amyl methyl ether (TAME), or tertiary amyl ethyl ether (TAEE). D. Potable water at ambient temperatures. F. Any gasoline/water/ethanol or methanol blend including 100% ethanol, ' methanol, or M85 (85% methanol) at ambient temperatures. III. Will not leak for a period of thirty (30) years fromdate of original purchase due to structural failure, which shall be defined as spontaneous breaking or collapse, provided the tank is used in the manner described in this Warranty and that the original installation . and any post -installation repairs or alterations to the tank (and collar) have been (A) carried out in the United States, (B) performed and validated by a contractor educated in proper tank installation, who possesses any required registrations, certificates or licenses, to complete the installation, repair or alter- ation in accordance with recognized industry practices and applicable regulatory requirements, and (C) that the tank system has been operated and maintained in accordance with regulatory requirements designed to minimize the possibility of structural failures and releases of regulated substances. After initial installation of the tank, the tank installation check -list supplied by F.C.I. must be properly com- pleted by the contractor and the owner's representative, and the owner must retain the complete checklist to verify proper installation of the tank. The complet- ed check -list must be delivered to F.C.I. at the time, of any claim under this warran- ty, and failure to so deliver may result in denial of the claim at the discretion of F.C.I. If the tank is remanufactured or removed from the ground for any reason prior to the expiration of this warranty, the structural warranty protections of this paragraph III will terminate unless the tank (and collar) are 1) inspected, repaired (as necessary), and recertified by F.C.I. and 2) upon reinstallation, continue to satisfy the other provisions of this paragraph III. FC.I.'S LIABILITY UNDER THIS WARRANTY SHALL BE LIMITED, AT OUR OPTION, TO (I) REPAIR OF THE. DEFECTIVE TANK (AND COLLAR) (II) DELIVERY OF A • REPLACEMENT TANK (AND COLLAR) TO THE POINT OF ORIGINAL DELIVERY, OR (III) REFUND OF THE ORIGINAL PURCHASE PRICE. AND F.C.I. SHALL NOT BE LIABLE FOR ANY LABOR OR OTHER INSTALLATION COSTS AND SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, CONSEQUENTIAL OR OTHER DAMAGES EXCEPT AS STATED ABOVE IN CONNECTION WITH SUCH TANK (AND COLLAR), INCLUDING, WITHOUT LIMITATION, COSTS, EXPENSES OR LIABILITIES ASSOCI- --D WITH ENVIRONMENTAL CONTAMINATION, FIRES, EXPLOSIONS OR ANY ,ER CONSEQUENCES ALLEGEDLY ATTRIBUTABLE TO A BREACH OF THE WARRANTY OR DAMAGES UNDER DECEPTIVE TRADE PRACTICES OR SIMILAR CONSUMER PROTECTION ACTS. THE FOREGOING CONSTITUTES OUR EXCLU- SIVE OBLIGATION AND F.C.I. MAKES NO EXPRESS OR IMPLIED WARRANTIES, OR ANY WARRANTY OF MERCHANTABILITY. OR FITNESS FOR ANY PARTICULAR PURPOSE WHATSOEVER, EXCEPT AS STATED ABOVE. Accessories Warranty • All double -wall tank accessories and monitoring equipment are warranted to be free from material defects in workmanship and materials for a period of one,(1) year following date of original delivery by Fluid Containment. Fluid Containment's liability under this warranty shall'. be limited, at our option, to (i) repair of the' defective unit, (ii) delivery of a replacementunit to the point of original delivery, or (iii) refund of the original'price. F.C.I. and shall not be liable for any labor or other installation costs and shall not be liable for any special indirect, consequential or other damages except as • stated above in connection with such tanks', including without limitation, costs, expenses orliabilities associated with environmental contamination, fires,. explosions or any other consequences allegedly • • attributable to a breach of the warranty or damages under deceptive trade practices or similar consumer protection acts. THE FOREGOING CONSTITUTES OUR EXCLUSIVE OBLIGATION AND FC.I: MAKES NO EXPRESS OR IMPLIED WARRANTIES, OR ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE WHATSOEVER,: EXCEPT AS STATED ABOVE. • Failure to install the tank accessories or monitoring; equipment in accordance with the Fluid • Containment installation instructions will void • the warranty. Fiberglass Tanks Intended Use' • Fiberglass petroleum storage double -wall tanks are designed for the storage of gasoline, alcohol blended gasoline (with up to 100% methanol or ethanol), jet fuel, av-gas, motor oil, kerosene, diesel fuel, oxygenated fuels (up to 20 % MTBE), or potable water at ambient underground .temperatures. Fuel oil may be stored at temperatures not to exceed 150°F. • The storage of other liquids may result, in tank failure. Before storing liquids other than those listed above, contact Tank Technical Support. Installation Overview Fiberglass underground tanks must be installed in accordance with the installation instructions • (Fluid Containment Pub. No. INST 6001). This document should be part of your tank specifications'.. :Some key installation steps are highlighted below, See the published installation instructions for complete details. Double -wall tanks must be mechanically unloaded 'from the delivery truck using a backhoe. or crane (using all lift lugs provided to lift the tank).'. A special air test procedure is required fordouble- 1 wall tanks that do not include factory installed 'monitoring fluid. A special air test:fixture is shipped with the tank. Fiberglass tanks•rnust be pressurized and inspected for leaks using a,soapy water solution... Leak testing prior to installation helps insure that fiberglass tanks were not damaged in shipment. If the double -wall tanks are shipped with factory - installed monitoring fluid, a simplified jobsite hydrostatic test procedure can be used. Installation for double -wall tanks is similar to the procedure for single -wall tanks. Fluid Containment requires pea gravel or crushed stone backfill material;: pea gravel is a naturally rounded aggregate ranging,', from 1/8" to 3/4" diameter. Washed crushed stone • 32 k (1/8" to 1/2" diameter) meeting ASTM C-33 may be used. Other backfill materials must not be used without consulting Fluid Containment forwritten approval. A minimum of 12" backfill bedding is required between the tank and the excavation bottom or con- crete anchoring pad. Tanks must not be installed on timbers, beams or cradles. If the Hydrostatic Tank Monitoring system is activated by filling at the jobsite, the tank cavity must be filled by pouring the'liquid into the cavity. Depending on local climate, use tap water or an acceptable antifreeze mixture:. as the monitoring fluid. All tanks mustbe vented and are intended. to be operated with fluid in the tank no higher, than the tank:top. Fiberglass tanks are designed for operation at atmospheric pressure only, except when using vapor recovery systems, provided the pressure or vacuum does not exceed 1 psi maximum on the primary tank: Overpressurizing of the I primary tank will result in tank failure. The monitoring cavity between the inner and outer' tank must be vented independently from the primary tank. For additional details, request Underground Tank Installations (Fluid Containment Pub. No. INST 6001). Properly installed, fiberglass,, underground petroleum storage tanks can provide extended service in storing petroleum, products without corrosion -caused leaks and 1. without maintenance. Fluid Containment maintains a listing of over 2,000 independent contractors who have received educational materials from Fluid Containment covering the proper installation of underground fiberglass tanks. On request, we can provide names of educated contractors. Double -Wall Fiberglass Tanks For Fuel Storage Model DWT-Type II Specification: Short Form Auto -cad drawings are available through your. local sales representative. The contractor shall provide U.L. labeled'. Model DWT-Type II double -wall fiberglass underground storage tanks in sizes and with fittings as shown on the drawings. The tanks shall be manufactured by Fluid Containment. Tanks shall be tested and installed with pea gravel or approved alternate backfill material according to the current installation instructions (Fluid Containment Pub. No. INST 6001) provided with the tank. Long Form: Section 13200 Guide Specification Fluid Containment Double -Wall Fiberglass Reinforced Polyester Underground Storage Tanks Auto -cad drawings are available through your local sales representative. `seed Part f General 1.01 Related Work Specified In Other Sections A. Cast -in -Place Concrete: Section 03300 B. Anchor Bolts: Section 05501 C. Plastic Pipe: Section 15064 D. Liquid Level Gauges: Section 15174 E.. Other Related Work - such as Excavation and Boiler Equipment 1.02 Quality Assurance A. Acceptable Manufacturers: • Fluid Containment,, Conroe, Texas. B. Governing Standards: 1. ASTM Specification D4021. Glass Fiber Reinforced Polyester Underground Petroleum Storage Tanks. 2. U.L. 1316. Underwriters Laboratories, Inc , Glass Fiber Reinforced Plastic Underground Storage Tanks for Petroleum Products. 3. National Fire Protection Assoc: (NFPA 30) Flammable and • Combustible Liquids Code and (NFPA 31) Standards .for Installation of Oil Burning Equipment. C. 4. General Services Administration, Public Building Service Guide Specification, PBS: 1568. • 1.03 Submittals: A. Shop Drawings:,Contractors shall submit copies of shop drawings for each tank. Drawings shall include all critical dimensions and show locations of all fittings and accessories, i.e., manways, ladders, hold-down straps, heating coils, etc. Materials of construction shall be in accordance with Section 1.02 of this specification. B. Catalog Data: Contractor shall submit copies of manufacturer's literature. C. Certification Plate: U.L. labels shall be affixed to each tank. D. Installation Instructions: Contractors shall submit copies of manufactur- er's latest installation instructions. E. Calibration Charts: Contractors shall submit copies of manufacturer's latest calibration charts.' Part II Products 2.01 Double -Wall Fiberglass Underground Storage Tanks A. Loading Conditions -Tank shall meet the following design criteria: 1. External hydrostatic pressure: Buried in ground with.7' of over burden over the top of the tank, the hole fully flooded and safety factor of 5:1 against general buckling. 2. Surface loads: When installed accord- ing to manufacturer's installation instructions, tanks will withstand surface H-20 axle loads (32,0001bs./axle). 3. Internal load: Primary and secondary tanks shall withstand 5 psi air pressure test with 5:1 safety factor. 4. Tanks shall be designed to support accessory equipment such as heating coils, ladders, drop tubes, etc. when installed according to manufacturer's recommendations and limitations. 5. Tank laminate shall include silica D. treated with silane: Product Storage Requirements:' 1. 'All primary tanks must be vented. Tanks are: designed for operation at atmospheric pressure only, except for use with vapor recovery systems at a pressure or vacuum of approximately 1 psi. 2. Tanks shall be capable of storing • liquids with specific gravity up to 1.1. 3. Maximum': temperature: Tank 'shall' be capable of storing gasoline, alcohol blended gasoline (with up to00% methanol or ethanol), oxygenated fuels (up to 20% MTBE), av-gas, jet fuel, motor oil, (new or used), kerosene,: diesel fuel or potable water at ambient underground temperatures not to exceed 150°F at thetank interior surface. 4. Tanks shall be chemically inert to petroleum products. Dimensional'. Requirements (refer to Fluid Containment literature on gallonage): 1. Nominal capacity of the tanklshall be. gallons. 2. Nominal outside diameter ofthe tanks shall be feet. 3. Nominal overall length of thetanks shall be feet. Monitoring Capabilities: 1. Tanks shall have a space between the primary and secondary shell walls to allow for the free flow and containment of all leaked product from the primary tank.: 2. The following continuous monitoring conditions shall be compatible' with the cavitybetween'the inner and outer tanks: • Vented'to.atmosphere • Vacuum - 5 psi maximum Positive air pressure (5,psi maximum) • External hydrostatic pressure - 7' maximurn groundwater head pressure over tank top. 3. Tanks6' diameter and iarger' shall have an integrally mounted reservoir' installed on the tank for optional hydrostatic monitoring. The reservoir shall be constructed of fiberglass reinforced plastio,materials and warranted for 30 years against failure due to internal/external corrosion and, when properly installed, against struc- tural failure (same' as tank warranty). 'Tanks 4' diameter DWl:6 Type II tanks do not include a4iberglass reservoir: A 4" diameter riser pipe screwed:into the 4" diameter annular, space fitting,will serve as the reservoir. 4. Tank shall be designed with one 4" ' fitting that will access the tankbottom between the primary and secondary walls (annular space). 5. The double -wall tank monitor shall be capable of detecting a breach in the inner and/or outer tank under the following installed conditions: : a. When the inner tank is empty. b. When the inner tank is partially 33 or completely full and the groundwater table is below the tank bottom. c. When the inner tank is partially or completely full and the tank is partially, or completely submerged in groundwater. 6. ' The leak detection performance of the monitoring system shall be tested and verified by a qualified independent consultant to detect leaks as small as 0.10 gallons per. hour with a 99.9% probability of detection andless than a 1.3% probability of a false alarm. 7. All monitoring equipment, including FRP reservoirs and electronic controls, shall be U.L. listed or accepted. 8. If hydrostatically monitored, any solution used in the tank annular space shall have U.L. approval for compatibility with the tank and be a contrasting color to the tank surface to facilitate visual inspection of the tank for leaks ,prior to burial. 2.02 Accessories Anchor Accessories A. Anchor Straps - Provide glass fiber - reinforced plastic anchor straps for each tank shown. Number and location of straps shall be as specified by manufacturer. Each strap shall be capable of withstanding a maximum load for each tank diameter as shown. 4'o - 4,200 lbs. 6'o 18,000 lbs. 8'o — 25,000 lbs. 10'o — 32,000lbs. Straps shall be standard as supplied by the tank manufacturer. B. Certification Plate - Underwriters Laboratory label shall be permanently affixed to each tank. C. Flanged Manways 1. The standard manway is 22" ID. The 30" and 36" ID manways are optional. One 22" manway is provided with each tank. 2. All manways will be furnished complete with U.L. listed gaskets, bolts and covers. 3. Location — see standard tank drawings. 4. a. 4' diameter tanks and less than 550 gallons, the steel manway cover shall have five fittings. For tanks 600 gallon to 1000 gallon the steel man - way cover shall have four fittings. b. 6' diameter tanks 2500 gallon shall have five fittings in the steel manway cover and 3000 gallon to 6000 gallon tank shall have three fittings in the steel manway'cover. c. 8' diameter tanks 5000 gallon shall have five fittings in the steel manway cover, 6000 gallon tanks shall have four fittings, and 8000 gallon tanks and greater shall have three fittings. d. 10' diameter tanks 10000 gallons E: shall have five fittings in the steel manway cover, 12000 gallon shall have tour fittings, and 15000 gallon" tanks and greater shall have three fittings. The steel mahway Over is standard with 4" diameter NPT fittings. 22" manway covers with an even number of fittings will be placed on an 8" radius. Manway covers with an odd number of fittings will have one fitting centered and the reamining fittings placed on an 8" radius. 30" manway cover fittings are standard 12" radius. 36" manway cover fittings are stan- dard 15" radius. 5. Manway risers 48" in diameter and 42" high will be supplied to provide access to the manway lid. A 24" x 24" galvanized street box with a cover must be provided by, contractor for at grade installation. 6. Fiberglass manway extension tubes 24" long will be provided for the man- ways as outlined in Section 3 above. Fill Tubes - Fill tubes of appropriate. design will be supplied by contractor. Hydrostatic Monitor Accessories 1. Brine Antifreeze Brine Solution Designation: BAS-30 Chemical Composition: 30%+ calcium chloride, 1% to 3% potassium chloride, 1 % to 2% sodium chloride, Balance water Visual Appearance: Green in color, Odorless fluid • Specific Gravity @ 60°Fd 1.272-1.317 Factory installed on tanks 30,000 gallon and under. Bulk brine jobsite installed on 35,000 gallon and 40,000 gallomtanks. 2.• Reservoir Sensor - I The FHRB 810 reservoir sensor is specifically designed for installation in the reservoirs of FCI double wall tanks. The components of the sensor are compatible with FCI supplied brine solutions. The sensor is also compatible with any other control panel that accepts normally open or closed switches. The: sensor provides two alarm points: high brine and low brine. The sensor can be wired to a control panel to provide only a single alarm (not distinguishing between high or low alarms) or it can be wired to report both' alarm conditions. 3. Electronic Controllers for Reservoir Sensor - The FHRB 810 reservoir sensor interfaces with the following FCI leak control panels: CPF 1, 2, 3 and 4; or inventory panels: CPI IH and CPI 4. The FCI control panels and reservoir sensor shall be U.L. or Factory Mutual listed as intrinsically safe: The correct number of input circuits must be used, either one or two, to provide the type of desired alarm reporting, i.e. single alarm or dual alarm (high brine or low brine). Additional leak detection sensors and inventory . monitoring probes shall be available to interface to the control panels. All control panels shall include: • Alarm lights for each circuit • Audible Alarm with Reset Button • System test button r,. • NEMA 4 Housing • Wall Mounting Capabilities • Dry Contact Relay for each input circuit • RS 232 port (Inventory Panels) • ALPHA numeric display (Inventory Panels) • Printer Option (Inventory 'Panels) Note: All wiring materials are provided by the contractor. Wiring is required from the power source to the control panel and from the control panel to the probe and sensor. assemblies. 4. Tank Gauge Probe -The IPFW Series tank gauge probe shall be capable of continuously monitoring', liquid levels and,detecting water in . hydrocarbons at, the bottom of tanks. The probe shall be compatible with the liquid it is intended to be submerged in and sized properly to fit into the tank without damaging the tank during installation or operation.'. The tank gauge probe shall not be., rigidly mounted in the tank. F. Non -Sealed FRP Turbine Enclosure (Model NTE Series)' -The non -sealed turbine enclosure consists of 'a fiberglass reinforced plastic (FRP) enclosure body (variable length in 12" increments, 42" or 48" ID's), an FRP reducer',(42"x30" or 48"x30" ID's), and a loose fit FRP lid with handle. The reducer opening must be large enough (minimum 28") to allow for. the removal of a 22 manway lid. The lid OD must be small enough to be removed through a 36" street box. The:, enclosure body must be capable of joining to the 42" or 48" diameter secondary containment collar with a leaktight adhesive joint. Cut lines for field trimming will be marked on the bottom 12" of the enclosure body in 3" increments.: Model No. Length NTE48-2 2' NTE48-3 3' 'I NTE48-4 4' NTE48-5 5' NTE42-6 6' NTE48-6 6' If needed, refer to Section. H for the optional adhesive kit (to bond the enclosure body to the containment collar) and Sections K, L, M and N for the field installed' fitting kits (for electrical and plumbing connections to the turbine enclosure). G. Watertight Turbine Enclosure (Model, WTE Series) - The watertight turbine , enclosure consists of a fiberglass rein- forced plastic (FRP) enclosure body (variable length in 12" increments, 42" or 48" ID's), an FRP reducer (42"x30" or 48"x30" ID's) witno-ring groove and o-ring gasket, and apush on ,FRP lid with 2 handles. The reducer opening must be. large enough (minimum 28") to allow for Model No. Length NTE42-2 2' NTE42-3 3' NTE42-4 4 NTE42-5 5 34 the removal of a 22" manway lid. The lid OD must be small enough to be removed' through a 36" street box. The enclosure body must be capable of joining to,the 42" or 48" diameter secondary contain- ment collar with a leaktight adhesive joint.. The reducer must be capable of joining to the enclosure body with an external leaktight adhesive joint to allow for field I. installation of the adhesive without entering' the enclosure. With the lid installed, the assembly must • provide a watertight seal with water up to 12" over the lid. The lid includes a non-skid exterior surface and must be able to support a person standing on the lid without damage to the lid. One of the lid handles is to be offset to aid in the removal of the lid and the other is cen- tered on the lid. Cut lines for field trimming`. will be marked on the bottom 12" of the enclosure body in 3" increments. Model No. Length Model No. Length WTE42-2 2' WTE48-2 2' WTE42-3 3' WTE48-3 WTE42-4 4' WTE48-4 WTE42-5, 5' WTE48-5 WTE42-6 6' WTE48-6 3' 4' 5' Refer to Section H for the adhesive kit (to bond the enclosure body to the con- tainment collar and to bond the reducer to the enclosure body) and Sections J, K, L and M for the field installed fitting kits (for electrical and plumbing connections to the turbine enclosure). H. Sealed .FRP Turbine Enclosure (Model STE Series) - The sealed turbine enclosure consists of a fiberglass reinforced plastic (FRP) enclosure body (variable length, 42" or 48" ID's), an FRP', reducer (42" or 48" ID's) with an oval flanged manway (23"x29" ID's), a flat gasket, 85 bolts with non -galling silicone- bronze nuts (or optional bolt ring), and an oval FRP lid with handle. The reducer opening must be large enough (minimum, 28") to allow for the removal of a 22" manway lid. The, lid OD must be small enough to be removed through a 36" street box. The enclosure body must be capable' of joining to the 42" or 48" diameter secondary containment collar with a leaktight adhesive joint. The reducer with oval flanged manway must be capable of joining to the enclosure body with a leaktight adhesive joint. With the lid installed, the assembly must provide a watertight seal with water up to .7' over the ,lid. The lid may be supplied with an optional 6" NPT fitting .with plug which can' be used as an observation ' port. Cut lines for field trimming will be Marked on the bottom 12" of the enclosure body in 3" increments. Model No. Length Model No. Length 2' ' 3' 4' 5' STE42-2 2' STE48-2 STE42-3 3' STE48-3 STE42.4 4' STE48-4 STE42.5 5' STE48-5 STE42.6 6' STE48-6 6' J. K. L. M. N. Refer to Section H for the adhesive kit (to bond the enclosure body to the contain- ment collar and tobond the reducer to the enclosure body) and Sections K, L, M and N for the field installed fitting kits (for electrical and plumbing connections to the turbine enclosure). Turbine Enclosure Adhesive Kit (Kit -AD) - When, properly installed and cured, the adhesive kit provides a water tight seal to prevent the ingress of water. The adhesive kit includes 1/2 gallon of adhesive in a one gallon capacity can. The kit also includes catalyst (hardener), a wooden mixing' stick, a three inch wide plastic putty knife, 60grit sandpaper, and installation instructions. One adhesive kit is required for each turbineenclosure; the watertight and sealed turbine enclo- sures require two kits. Field Entry Boot (Model FEB-3 or FEB-4) The FEB-3 or FEB-4 is designed to interface with 3" or 4" nominal OD FRP pipe. FRP Coupling Kit - (Kit FC-3 or FC-4) is designed to interface with 3" or 4" nominal. OD FRP pipe manufactured by Ameron or Smith Fiberglass. The coupling ID is tapered at both ends. The two-piece coupling is constructed of fiberglass reinforced plastic and is field - installed using the supplied adhesive. Both pieces of the fitting are threaded together to hold the fittingin position, while the adhesive cures. • Kit FC-3 or Kit FC-4 includes one 3" or 4" nominal ID FRP coupling, adhesive, catalyst (hardener), plastic mixing stick and applicator, 60 grit sandpaper, and installation' instructions. The contractor must provide the hole. saw (4-1/2 or 5-1/2 inch 0D) or reciprocating saw to cut the hole in the turbine enclo- sure prior to installing the FRP coupling. Electrical Coupling Kit - Kit EC-1 is designed to interface with one inch steel electrical conduit.' The two-piece coupling is constructed of steel and is field installed using the supplied adhesive. Both pieces of the fitting are threaded together to hold the fitting in position while the adhesive cures. Kit EC-1 includes two one inch steel. couplings, adhesive catalyst (hardener), plastic mixing stick, 60 grit sandpaper, and installation instructions. The contractor must provide a two inch hole saw or reciprocating saw to cut the hole in the turbine enclosure prior to installing the steel coupling. Secondary Containment Collar - The secondary containment collar shall be constructed of fiberglass reinforced plastic. Collar shall be 42" or 48" in diameter and will be factory -installed in accordance with drawings. The collar will include a sensor mounting bracket. Containment Collar Sensor is pre - assembled and ready to wire. All electrical components must be U.L. listed of accepted. This float switch sensor is capable of detecting a 2" or more accumulation of liquid (water or product) in the turbine enclosure.'' The float switch is constructed of'Buna-N; the float switch is housed in plastic casing and includes a mounting clamp. Ladders - Ladders shall be the standard ladder supplied by the tank manufacturer (carbon steel, stainless steel, aluminum). Refer to drawings for location. P. Tank Lilting Lugs - Provide lifting lug(s) on all tanks. Lifting lug system shall be capable of withstanding weight of tank with a safety factor of 3:1. Q. Probe Drawstring - Nylon line shall be 150.Ib. break strength located at the monitoring fitting nearest the end of the tank. When a reservoir is located at this position, the drawstring shall be installed within the reservoir: Drawstring length will allow for a 7' tank burial depth. R. Fittings Threaded — NPT 1. All threaded fittings on'. U.L. labeled tanks. shall be located in a manway lid or a tank mount within 12" of the tank top center line and be constructed consistent with the requirements of the U.L. label. Fittings to be supplied with threaded cast iron plugs. 2. All standard threaded fittingsto the pri- mary tank and monitoring cavity are 4" in diameter. The standard secondary containment coupling is 6" in diameter. All standard threaded fittings are'' half couplings. Reducers are to be used for smaller sizes where specified and provided by contractor. 3. Thread Standards—iAllthreaded fittings shall have machine tolerances in accordance with the ANSI standard for each fitting size. 4. Strength — Primary tank,NPT fittings will withstand a minimum of 150 foot-pounds of torque and 1,000 foot-pounds of bend- ing, both with 2:1 factor of safety.' 5. Sizes Standard Reducer Sizes Inlet 4 Outlet 4"' Vent 4 Gauge 4" Fill 4' 6. Location Refer to drawings' for location. 7. Suction Line — Shall be installed on site by the contractor. Diameter of pipe and grade and schedule as called out in other sections. 8. Return Line Shall be installed on the site bythe. contractor. Diameter of pipe and grade and schedule as called out in other sections. 9. All rigid internal piping shall be terminated at least 4" from the bottom of the tank. 3.01, 3.02 Installation And Testing',, Tanks shall be tested andinstalled according to the current installation instructionsprovided with the tank (refer to Fluid Containment Pub. No. INST 6001 and include as part of your specification). 35 Who Should Choose Fiberglass Underground Storage Tanks?. Fluid Containment's fiberglass under- ground storage tanks are designed with the latest technologies and under the strictest UL guidelines to meet a variety of needs. Each of our tanks comes with a 30 year, warranty against leakage and is guaranteed to NEVER RUST! For over three decades, not one of our tanks has ever suffered a corrosion -related leak. See our warranty for complete information. Fluid Containment fiberglass UST's are ideal for storing: • Gasoline • Jet Fuel • AV -gas • Motor oil (new or used) • Kerosene • Diesel fuel • Alcohol -gasoline blends • Ethanol -blends (Gasohol) • Methanol blends • Oxygenated motor fuels • Potable water • Any gasoline/water/ethanol or methanol blend including ethanol, methanol, or M85 FLUID CONTAINMENT A Containment Solutions Company Route 20, Box 1380 • Conroe, Texas 77301- 4124. (409) 756-7731 • Fax: (409) 756-7766, Order Entry/Technical Support Field Service (800) 537-4730 • Fax: (800) 839-4727 (814) 542-8520 • Fax: (814) 542-5020 Web site: www.fluidcontainment.com' 01997 Fluid Containment, Inc. All rights reserved. The Fluid Containment logo Is a trademark of Fluid Containment Inc. ■ ■ 1PE BP/SM/6-97, Pub. No. TNK1001 B, Litho in U.S.A. June, 199711) SLAB ANCHOR HARDWARE WITH TURNBUCKLE BOTH SIDES MFG:: TANK .SIZE: DIA.: CONTRACTOR: JOB: .50-CLIP 1/2', GALVANIZED MALLEABLE IRON CABLE CLIP (TYP.7 .75-JE 3/4-x12' GALVANIZED JAW x EYE TURNBUCKLE .75 EB 3/4-x15 GALVANIZE° EYE BOLT WITH NUT ITYP.1 CONCRETE PAD HOLD GOWN STRAPJPROVIDEC BY TANK MANUFACTURER .50-6x19 1/2- GALVANIZED IMPROVED PLOW STEEL CABLE PLATE-12"x6-x1/4' STEEL HOLD GOWN PLATE (TYP.,1 CAAP 1 11/11/E Shields, Harper & Co. 51O7SROADWAY • OAKLANO.CALIFORNIA 94611 • FAX(5107656-6446 • C5107.653-9119 FORGED EYE BOLTS REGULAR NUT .Galvanized, Forged Steel, Quenched arid Tempered Shank Diarn. and Length 'Inches Length Eye Dim. Safe Working. Load Pounds Weight Pounds Per 100 of Thread Inches I.D. Inches 0.D. Inches 1/4x 2 11 1/2 I 1 500 7.36 1/4 x' 4 21/2 I 1/2 1 500 12.36 5/16 x 21/4 11/2 5,4 11/4 800 13.25 5/,6 x 41 21h 5/6 11/4 I I' 800 19.50 3/9 x 21/2 ' 1 Y 3 11 1,200 24.33 % x 41 2 1/2 3/4 I 11/2 1.200 30.58 ? x 6 21 / 11/z 1,200 34.83 Yz x 31/4 11/2 1 2 2,200 54.75 1/2 x 6 3 1 2 2.200 74.00 1/2 x 8 3 11 2 2,200 78.00 1/2 x 10 3 1 2 2,200 88.00 1/2 x 12 3 1 2 2,200 105.00 % x 4 2 1 1/4 21/2 3,500 10125 5/3 x 6 3 11/4 21/2 3,500 124.25 YS x 8 I 3 11/4 21 3.500 131.00 5ta x 10 3 11/4 21/2 3.500 152.00 5/6 x 12 '' 4 11/4 21/2 3.500 186.25 314 x 41/2 2 11/2 3 5,200 161.44 2/4 'x 6 3 I 11/2 3 5,200 183.94 3/4 x 8 3 11/2 3 5,200 208.00 3/4 x 10 3 11/2 3 5,200 230.00 3/4 x 12 4 1 Yz 3 5.200 251.94 3/4 x 15 5 11 3 5.200 310.44 7/3 x 5 21/z 13/4 _ 31/2 7,200 283.60 7/3 x 8 4 13/4 31/2 7,200 319.85 7/a x 12 4 13/4 31/2 7.200 386.85 1 x 6 3 2 4 10.000 384.42 1 x 9 4 2 4 10,000 451.67 1 x 12 4 2 4 10,000 525.69 1 x 18 7 2 4 10.000 667.17 11/4 x 8 4 21/2 5 15,200 680.00 11/4 x 12 14 21/2 5 15,200 820.00 11/4 x 20 6 21/2 5 15,200 1,209.50 i V i RNEUCHLEw7 ]AW & EYE ' Meaa Fe,4 ni So•eiflotions PP.TA91 b Typo 1 Form 1 Casa Dro'c Forged • 1035 Steel DROP FORGED HEX BOOM . HOT DIPPED GALVANIZED 5:1 SAFETY FACTOR ■ USE FOR STRAIGHT OR IN -LINE PULLS ONLY AMer4w' ...,�.SM1TAK£VP .q ... a'vr-dgstg4.4 � ;nY �+ ✓:"' �1W�wCt Ir°_. 1/4 x a 8-1/4 .30 1 .32 'i .36 5/16 x 4.1/2 9-9/16 .63 .47 ', ,52 3/8 x 6 11.7/8 - .75 .76 '.'..a1 1/2. x 6 13-5/16 1.60 " 1.53 ;1.50 1/2 x 9 ' 16.5/16 1.23 1.71;.I'J4 1/2 xA 12 . 19-5/16 2.25 2.06 , 12.40 5/8 x ' 6 15-1/2 275 2.25 13.02 • 5/8 x 9 18.1/2 3.13 ". 3.C6 3.31 5/3 x 12 21-1/2 3.50 3.78 .14.20 3/4 x 6 17 3.89 ' 4.00 '14.11 3/4 , x 9 20 4.61 4.75 ',5.10 3/4 x 12 23 5.43 ' 5.36 "5.55 3/4 'x 18 29 7.25 7.00 7.00 7/8 x 12 24.5/8 8.10 8.00 '18J7 7/8 x 18 30-5/8 9.25 9.75 ' ' 19.00 1 x 8 20.5/3 9.23 ' 9.00 ;9.75 1 x 12 265/8 11.93 11.20 12.20 1 x 18 32.5/8 14.00 13.30 14.00 1 x 24 38.5/8 17.25 ' 17.00 17 CO 1.1/4 x 12 29-7/8 1s.00 20.00 11.50 1.1/4 x 18 35 7/8 23.00 24.18 25.50 1-1/4 x 24 41-7/8 27.00 27.50 28.0 1-1/2 x 12 32-3/8 27.50 28.50 3045 1.1/2 x 13 38-3/3 31.00 35.00 34.25 1.1/2 x 24 44.3/8 37.50 38.73 40.67 12/4 x 18 41.3/4 52.50 52.75 5E.C4 1.3/4 x 24 47.3/4 52.00 61.00 633E 2 x 24 51-3/4 85.25 89.00 ' 44:0 2-1/2 x 24 i 58-1/2 144.25 150.00 165.0C 23/4 x 24 ' 61.1/2 194.00 '. 183.00 198.00 OAKLAND SACRAMENTO FRESNO SAN JOSE STOCKTON Shields,. Harper S. Co. 11076ROAOWAY • OAKLAND. CALIFORNIA 94611 • FAX (5101 65E1-8446 • (5101653-9119 6x19r, Ga(v • Wire Hop ��. --Inches -L- '- Minim eter�" ' '`. NOMINAL STRENGTH IN TONS OF 2,000 POUNDS • :,. + , 'Approximat+. 'Footm_...^ 'Pounds-. ••„Gale Improved Plow Steel -:6x79 ^.•. '. - -•,--core-•--Faatr'. IWRC Core cars IWRC FC. IWRC 1/4 6.3 2.55 • ,105 .116 5/16 79 . 4.12 • .161 .180 3/8 9.5 5.90 .236 .260 7/16 1117 1/2-:'-. 127' 10.33 .. .42' 6 ..'.S9 9/16 14.3`- , _ J.-MAI .63 5/8 15.9 16.10 '' ,66 .72 3/4 19.0 23.00 95 1.04 7/8 22.2 31.10 1.29 1,42 T:r., 25.4•. 40.40 t.63' - 125 -. 1.1/8 28 6 .. ,5050 - 1 2.13 : 2_34 .- 31.7 .; ... !' 1.1/4 '. -, 2.63 2.39 -. 1 'J8 34,9• 75.10 _' 3.18 350 1.1/2 38.1 89.00 3.78E 4,16 15/8 _41.3 - 103.00 _ 4.44 4.33 '`1.3/4 44.4. 50.8' _ 120.00. 155.00 5.15 6.72 5.5-1p7 7.. Malleable IN CLIPS MEET FEDERAL SPECIFICATION FF•C•450',TYPE 1 CLASS 1Y MALLEABLE IRON ZINC PLATED 1, ALL NUTS REGULAR HEX TYPE a 4.1-`t„i--y�"%s....'ttU,_ 1 a�R11- IM E. Slp ins .arr�.snra +..rc` a i-71 ^9 1/8 3/16 1/4 2 2 2 1/4 1/4 5/16 13/16 31/32 1.7/32 1/2 5/8 7/8 1/2 9/16 11/16 ''7/16 1/2 5/8 1/2 9/16 11/16 13/16 1.1/16 7-pie '4.3 8.3 14.5 5/16 3/8 7/16 2 2 3 5/16 3/8 3/8 1.7/32 1-5/8 1-5/8 7/8 1 1 11/16 7/8 7/8 11/16 "13/16 13/16 11/16 7/8 :.15/16 1-2/8 1-5/8 1-5/8 15 21.5 24 1/2 9/16 5/8 13 3 3 7/16 1/2 1/2 2 2-5/16 2-5/16 1.1/4 1-15/32 1-15/32 1 1.3/16 1-3/16 1-1/16 1=3/16 1-5/16 1 1-1/8 1-1/8 1-7/8 2-3/16 2.0/16 37 55 59 3/4 7/8 1 ' 4 4 4 9/16 5/8 5/8 2-9/16 3-1/16 3-3/8 1-3/4 1-13/16 2.1/16 1-11/32 15/8 1-3/4 1-1/2 1.3/4 1-15/16 1.1/4 1-3/4 2 2 7/16 2-7/8 3 84 128 150 1-1/8 1.1/4 1-3/8 1.1/2 . 5 5 6 6 3/4 3/4 7/8 7/8 3.7/8 3-7/8 4.1/2 4-1/2 2-3/16 2-3/16 2 2- 2-1/16 2-1/16 2-9/18 - 2-9/16 2-3/16 2-3/8 2-7/8 3 2-1/8 2-1/2 3-1/8 3-1/4 37/16 3-7/16 4-3/16 4.11/4 241 262 456 512 NOTE: MALLEABLE CLIPS ARE NOT DESIGNED FOR OVERHEAD LIFTING OAKLAN0 SACRAMENTO FRESNO SAN JOSE - STOCKTON Chn FiL-SPIL CONTAINMENT BOX MANUFACTURING SPECIFICATIONS: • OUTER RING: HEAVY CAST IRON IN 30" DIA., 38" DIA., 42"DIA. AND 48"DIA. • SKIRT: 14 GAUGE SHEET METAL. • COVER: 3/8" FLOOR PLATE, REINFORCED, COMPLIES WITH. H2O RATING. • STANDARD FILL COVERS: DUCTILE IRON COVERS WITH FINGER HOLES, COMPLIES W/H20 RATING: • PULL DRAIN VALVE ASS'Y.: 2 PIECE ALUMINUM. C.A.R.B. APPROVED. • GASKET: TUBE FLANGE DESIGN, LOW SWELL, HIGH NITRILE RUBBER, COMPATIBLE WITH METHANOL UP TO 857... FEATURES: '.*RAIN TIGHT. •SPECIAL DESIGN ON COVER WILL NOT ALLOW DIRT OR WATER TO ENTER THE CONTAINMENT. AREA. •DOES NOT ALLOW WATER INTO THE GROUND. • ALLOWS FOR VAPORS TO ESCAPE WHILE THE FILL COVER IS ON. •STANDARD 5 GAL. CONTAINMENT AND TWO PIECE HARD COAT ANNODIZED ALUMINUM VALVE FOR ONE RISER SYSTEM (C.A.R.B. APPROVED).. •DRAIN HOSE IS DESIGNED IN A -DOWNWARD POSITION AT ALL TIMES, ALLOWING FOR A RAPID FLOW. • STAINLESS STEEL OUTSIDE BRAID AND TEFLON INNER HOSE WITH 1/2" MALE AND 1/2" FEMALE SVC AIRCRAFT FITTINGS. • BELLOWS STYLE SEAL ALLOWS FOR FREEDOM OF MOVEMENT, EITHER SIDE TO SIDE OR UP AND DOWN, WITHOUT DAMAGE TO PIPE RISER OR TANK, IS EASILY. ACCESSIBLE FROM INSIDE. •4" X 17" SCH. 40 PIPE, WITH A WELDED ,STRAIGHT JVC FITTING. • SCREWS AND GASKET TO ASSURE WATER -TIGHT FIT. •UNIT CAN BE ORDERED WITH PIPE PLUG AND UP TO 40 GALLON CONTAINMENT. • C5-A ANTI -SEIZE LUBRICANT SHOULD BE USED ON SCREWS EACH TIME COVER IS REMOVED. ONE DOOR CENTER 30" DIA. 36" DIA. 42"'DIA. 48" DIA. 0 CONTAINMENT 30-35 36-35 42-35 48-35 5 GALLON 30-36 36-36 ---- ---- ---- 10 GALLON 30-37 36-37 ---- OPTIONS: C = CAM-LOKS OSG = 7X7 OBSERVATION DOOR W/SCREWS AND GASKET S = SNOW PLOW RING 8" STANDARD OFFSET, 36" & UP U.N.V. JJUUn tn. r.Jr,1 MAX 5" OFF CENTER ON 30" 30" DIA. 36" DIA. 42" DIA. 48" DIA. NO CONTAINMENT 30-40 36-40 42-40 48-40 5 GALLON 30-41 36-41 ---- ---- I n GALLON 30-42 36-42 ---- ---- OPTIONS: C = CAM-LOKS S = SNOW PLOW RING OSG = 7X7 OBSERVATION DOOR W/SCREWS &GASKET PATENT I{5,372,453 PATENT'. #5,372,453 (SPECIAL ORDER ITEMS AVAIL UPON REQUEST) 12 BAKER INDUSTRIESNORTHWEST,'- INC. 12428 Highway 99 South • Unit 56 • Everett, WA 98204 Phone (206) 745-6130 •' FAX (206) 353-6788 ROUND ACCESS BOXES For Grade Level Applications DESIGN FEATURES OF 400 SERIES: • Heavy Duty Steel Diamond Plate Lid, Rated For H2O Axle Loads. • Fully Recessed Steel Handle, Watertight. • Galvanized Steel Skirt. • Formed STEEL Support Ring. • BUNA-N Lid Gasket, Watertight Lid. • Recessed STAINLESS STEEL Security Bolts In Lid. • Manufactured In Everett, WA. NOTE: 300 Series Models 300-12RL thru 300-42RL same as above except do not include lid gasket or security bolts: (not a watertight lid) DISTRIBUTED BY: 1/94 MEMBER 2PEIg [w KWIPBFM mf Model 400-1 6R Model 400-36R DESCRIPTION MODEL SKIRT I.D. LID O.D. HEIGHT'' 400-12RL 12" 15" 10" 400-16R 16" 19" 13" 400-16RL 16" 19" 10" 400-18R 18" 21" 13" 400-18RL 18" 21" 10" 400-24R 24" 27" 13" 400-24RL 24" 27" ' 10" 400-30R 30" 33" 13" 400-3ORL 30" 33" 10". 400-36R 36 39" 13" 400-36RL 36" 39" 10" 400-42R 42" 45" 13" 400-42RL 42" 45" 10" * 'L' models are 10" rather than '13" high. * 12"-18" sizes do not include recessed handle unless specified. * Dimensions are approximate. * Other sizes produced on request. * 20" x 20" and 24" x 24" square access boxes available. �AC�'' MONITORING WELL BOX SPECIFICATIONS: OUTER RING: '.HEAVY CAST-IRON COVER: NON-SKID CAST IRON WITH DESIGNATION IN ACCORDANCE WITH API RP 1815. SKIRT: 14 GAUGE GALVANIZED SHEET METAL. PART# 112MWCL 118MWCL FEATURES: *HEAVY CAST IRON COVER, COMPLIES WITH H2O RATING. *COVERS HAVE CAM-LOKS TO ASSURE POSITIVE LOCKDOWN FROM ANY P6SITION. NO NEED TO ALIGN HOLES. 'STAINLESS STEEL 1/2" HEX BOLTS RECESSED FLUSH WITH COVER. •14 GAUGE GALVANIZED SKIRT. *CAM-LOKS CAN BE OPENED OR CLOSED USING A STANDARD 3/4" SOCKET. DESCRIPTION 12" MONITORING WELL WITH CAM-LOKS 18"' MONITORING, WELL WITH CAM-LOKS 20 A79 Float Valve Extractor (FRP) Overfill Prevention The FRP A79 Float Valve Extractor is designed never to corrode: It is made of fiberglass reinforced plastic so it is strong, yet lightweight. and easy to handle. The tapered smooth vent ports allow fiberglass vent lines to be fit and glued directly into the extractor body. This reduces the installation time and cost, as the special fiberglass pipe adapters needed to thread into a metal fitting are no longer required. The FRP A79 incorporates metal starter threads in the top for a stronger riser pipe con- nection. The molded in brass insert makes cage removal simple. The extractable brass cage utilizes the standard "bar" style wrench connection and can accommodate any 2" NPT Ball Float Valve. 2" and 3" tapered pipe plugs are avail- able for permanent field plugging of ports. y Model No Vent Port Manifold Port Tank Connection Riser Connection A B. A79-100 2" Tapered Closed Smooth A79-101 2" Tapered 3" Tapered Smooth Smooth A79-102 2" Tapered ?`Tapered Smooth Smooth A79103* .2" Tapered 3"Tapered Smooth Smooth "Includes a 2" and a 3" tapered, pipe plug for field retrofit. Weight: 43/4lbs. Replacement Parts: Cage: 493379 (FRP A79 Only), Cage: 493379, 2" Plug: 565563, 3" Plug: 565564 Optional Items: Brass Test Plug: 493380, Extractor Wrench: A560-003, Float Valve: A75, Installation Wrench: A81.002 4' Male NPT 4" Female NPT 9" 9 5/1''6" 4" Male NPT 4' Female NPT 9" 9 5/16" 4" Male NPT 4' Female NPT 9° 9 5/16" 4" Male NPT 4" Female NPT 9" 9 5/1I6" Note: The Brass Cage and Test Plug for the FRP A79 are not interchangeable with metal extractor fitting. Vents BUNCO® WHEATON Emco Wheaton manufactures a variety of vents for underground tanks for service stations, fuel oil, industrial, and commercial applications. To meet specific application requirements, Emco Wheaton vents are available in avariety of sizes, screen and filter options. Each can be readily installed on new or existing vent lines for§afe, dependable operation. Upward "V" Vent A The Upward "V" Vent utilizes a straight -up "V" design to rapidly disperse vapors. Slip- cn style vent attaches to the pipe with three screws for easy installation. Available in 1 1/2", 2", and 3' sizes. Removable feature permits cleaning of the screen. A grooved drain lip in the cap extends beyond the base for water drain -off. Designed in accordance with NFPA 30 and is U.L. listed. Model No. Inlet Weight B 493016 ' 11/2",2" 1/2'Ib. A4103-003* 3" 2 Ibs. Replacement Parts: Vent Cap: 563375, Vent Base: 563376, Screw: 563377 Material: Body: High Density Polyethylene, Screen: Stainless Steel, 40 Mesh *Body and cap made of Aluminum.', 5" 315/16" 57/8' 53/16 Miscellaneous Equipment Wrenches A560 Extractor Wrench Emco Wheaton Extractor Wrenches are required to install and remove the A584 pipe cap and appropriate angle check, foot; and float valve extractor cages. Two head styles are available. The historic Emco Wheaton Buckeye style wrench is used on all the metal extractors. The latest design FRP A79 requires the industry standard "bar'. style" wrench A560-003. Model No. Size Weight Extractor Pipe Extractor Fitting Cap 4560-001 11/2" 81bs. A584-003 A677-003, A560-002 2" 8 lbs. None A563-002, 004, A79, 021, 022, 023 A560-003 2" 8 Ibs. None FRP A79-100 101,102,103' Replacement Parts: None Tight Fill Products ENICO WHEATON Drop Tubes Emu] Wheaton dffers a range of drop tubes to match various fill system needs. These drop tubes are suppliedin a variety of lengths and are designed to be altered in the field to meet specific tank dimensions: Installing drop tubes is fast and simple and requires no exdavation. The drop tube is inserted in the riser pipe until it touches the bottom of the -tank. Next, the distance from, I the top of the tube or lugs to the top edge of :the riser pipe is measured, and 3" is added. Thiaength is then cut from the bottom' of the drop tube at a 45' angle. The tube is inserted into the tank and is ready for use. A20 Drop Tube The A20 Drop Tube is used in conventional non -vapor recovery and dual point vapor recovery fill systems. The drop tube fits directly into the tank riser pipe to permit tight fill submerged filling with reduced turbulence and minimal vapor lass. The A20 is constructed of lightweight aluminum for easy handling and installation. Completewith bursa gasket. Cut 45' in the field to fit. Use with the A30 Fill Adapter and A97 Tight Fill Cap.: Model No.. Size Length Weight Adapter' Bushing",''.. A20-002 A20-004 A20-006 (.065 Wall thickness) A20-008 4" •Items must be ordered separately. 11' 12 12 31/21bs. 51bs. 5Ibs. 114' 51/2 lbs. A30-014 A30-014 A30-014 A30-014 Phone (919)243-71E0 Fax (919)243.4503 1491689 Top Seal Caps A97 Tight Fill Cap Emcd Wheaton offers Top Seal Tight Fill Caps designed The A97Tap Seal Fill Cap is designed for use on all coaxial .adapters and the A30Adapter. Protects the adapter and prevents product contamin- ation.The A97 features art exclusive self -aligning, toggle - to rnata with fill adapters in various fill system config- urations. These caps supply a action design for easy .coup- ling and removal. Toggle pins and cams are stainless steel, links are plated steel. Provides even compression on a low swell compound gasket for long service life. Includes replaceable seats and padlocking capability., "snap -tight" seal and can be padlocked forsecurity. T JI t i l:--------j--fir B Model No. Material Seat Size Weight Works On Adapter Buna 4' Tight 11h. A30-014 25/8' 65l8' FII 2 oz. A89, AS6 Replacement Parts: Roll Pin (2 each): 562813. Cam 12 each): 562816, Link (2 each): 562818, Handle: 562619, River 562815 Seal: 563939 A97-005 FRP Tight Fill Products WHEATN Tap Seal Adapters Emco Wheaton Top Seal Adapters are designed to fit various 3" and 4" tank risers " drops. These adapters are and accommodate standard easy to install and provide and coaxial elbows for product secure seating on the riser. A30 Tight Fill Adapter The A30 Adapter is designed for use with conventional or dual point fill systems. Fea- tures recessed threads for easy installation and a buna Model No. Size. A30-014 4" Female NPT X 4" Male Tight Fill Replacement Parts. Buna Gasket: 409628 gasket for positive seating on standard riser pipes. Use with the A97 Tight Fill Cap and the Emco Wheaton F523 Elbow or equivalent. The A81 Adapter Wrench is recommended for installation. Material Weight Hardcoat 13.5 Ibs. Anodized Aluminum A 5 3/32 EMCO® WHEATON A75 Ball Float Meets EPA Requirements for UST Fuel Slowdown Device A75 Ball Float - 3" The 3" A75 is designed with a ball and stem which does not require a cage. NOTE: The A75 Ball Float should be used with the A79 Ball Float Extractor. A75 Ball Float Valve 3" Style Product Dimension Dimension Dimension '. Number A B C Total Length Tube Length Shut OH Length Bleed Hole Weight Material Inches MM Inches MM Inches MM Inches MM LBS KG A75-019 10.44 265 5.44 138 2.44 62 1/8 3.2 1.4 .63 Aluminum A75-021 13.88 347 8.68 221 5.69 145 1/8 3.2 2.1 .95 Aluminum A75-022 19.68 500 14.69 373 11.69 297 1/16 1.6 3.4 1.54 Aluminum A76-023 23.24 590 18.25 464 15.25 387 1/8 3.2 4.2 1.79 Aluminum 4/96 Printed in USA Emco Wheaton, Inc Retail Products Division 2300 Industrial Park Drive Wilson, NC 27893 Telephone: 919.243.0150 Facsimile: 919.243.4759 800-234-4394 EMCD® WHEATON A75 Ball Float Meets EPA Requirements for UST Fuel Slowdown Device The A75 Ball Float Valves are designed to restrict product flow in the event of a UST overfill and can be used to meet EPA's overfill requirement as a slowdown device. A75 Ball Float - 2" Cage damage on the 2" A75 is prevented by a unique stainless steel spring design which insures freedom of movement for the stainless steel ball float. Product Number A75-010 A75-011 A75-012 A75-013 A75-014 A75-015 A75.016 A75-017 A75-018 The A75 features a bleed hole to release the compressed air in the top of the UST in the event of an overfill. 4 2" NPT Threads - Domestic US Market Standard Dimension A Total Length Inches MM 22 5/16 567.18 27 13/16 706.88 28 13/16 732.28 30 13/16 783.08 35 5/16 897.38 22 5/16 567.18 27 13/16 706.88 13 1/2 343.15 18 1/4 463.80 Dimension Dimension B C Tube Length Shut OH Length Bleed Hole Inches MM Inches MM Inches MM 17 7/8 454.15 23 3/8 593.85 24. 3/8 619.25 26 3/8 670.05 30 7/8 784.35 17 7/8 454.15 23 3/8 593.85 9 1/16 230.12 1313/16 350.77 15 1/4 20 3/4 21 3/4 23 3/4 28 1/4 15 1/4 20 3/4 6 7/16 11 3/16 387.35 527.05 552.45 603.25 717.55 387.35 527.05 163.32 283.97 1/8 1/8 1/8 1/8 1/8 1/16 1/8 1/16 1/16 3.20 3.20 3.20 3.20 3.20 1.60 3.20 1.60 1.60 Weight LBS KG 1.75 2.00 2.25 2.33 3.00 4.00 3.00 4.00 8.00 0.79 0.91 1.02 1.06 1.36 1.81 1.36 1.81 3.63 Bleed Hole, Material Aluminum Aluminum Aluminum Aluminum Aluminum Galvanized Galvanized Galvanized Galvanized m ma �mrmm=a+ re, m s s n ors- w _ STJ ea'Sm M6I ,: �y..is'.4i �.� .. .1. ram•."^`�'' .I s .�.TS T_i1H.. • _ It—IDxR T .. -I--'IRL `e` lI�T Intelligent Controls, Inc. is a leading manufacturer of automatic tank gauge and leak detection systems for underground storage tanks and piping. The company was founded in 1978 and specializes in the design and manufacture of microprocessor based electronic monitoring equipment for the electric utility, industrial automation, and petroleum equipment industries. Over the years, INCON has become a leader in the development of innovative, cost-effective products, which meet the business and regulatory needs of petroleum marketers. In 1989 INCON entered the petroleum equipment industry as a supplier of automatic tank gauge circuit boards and software to two prominent petroleum equipment manufacturers. In 1991, we introduced the Tank Sentinel line of automatic tank gauge and leak detection systems bringing the first low cost, full featured, automatic tank gauge and leak detection system to the market. The TS-1000 series, available in 2 or 4 tank configurations, offers the petroleum marketer the flexibility and expansion capabilities of modular systems at a fraction of the price. It simply represents the highest value of any system on the market. INCON's leak detection systems are sold and serviced throughout the world by petroleum equipment distributors. Our philosophy from the. start has been to offer the marketer top quality, full featured, affordable products that work better and cost less than competitive systems. Please contact us for more detailed information on our products or simply tear out the literature ordering form at the end of this brochure and fax it to one of the district sales offices or to the factory. INCON Tank Sentinel Product Brochure PN 000-1483 Rev: B Effective 1/13/96 TANK SENTINEL° ATG CONSOLES TS-1000/OEFI LEAK DETECTION MONITOR • State-of-the-art leak detection monitor that includes 8 inputs'', for monitoring sump spaces, interstitial spaces, and monitoring wells • Available with a versatile selection of discriminating and non -discriminating sensors • Third party approved leak monitoring console and leak detection sensors • Easily field upgraded into a TS-1000/2 or TS-1000/4 full featured ATG • Advanced RS-232 serial communications including four number auto -dialing with an optional TS-M modem • Battery -backed memory preserves configuration and alarm history (applies to all consoles) • Available with an optional 24 column thermal printer • Programmable alarm setup can, tie any combination of alarms to output relays • Interfaces with INCON's new TS-LLD electronic line leak detector • Dimensions: (H)12.25"x(W)10.25"xID)6.375" (H) 31.1 cmx(W)26.0cmx(0)16.2cm TS-1000EFI AUTOMATIC TANK GAUGE (ATG) & LEAK DETECTION CONSOLE • Available in a 2 tank or4tank configuration using magneto- strictive level probes • Includes 8 inputs for monitoring sump spaces, interstitial spaces and monitoring wells, using INCON's versatile selection of discriminating and nondiscrimi- nating sensors •Third Party approved for volumetric tank tightness testing ata 0.1 gph leak rate with a 99.2% probability of detection • Available with SCALD statistical continuous automatic leak detection • Expansion capability allows the number of relay outputs, leak sensor inputs and more, to be easily added. • Available with or without a 24 column thermal printer • Highly visible, back lit, 2 line,16 character LCD display • Includes a full featured RS-232 communication port with auto dialing capability • Interfaces with INCON's new TS-LLD electronic line leak detector • Dimensions: (H)12.25"x(W)10.25°x(0)6.315". (H) 31.1 cm x (W) 26.0 cm x(D116.2 cm CON J TANK SENTINEL® ATG CONSOLES BACKUP GENERATOR ATG CONSOLE • Complete ATG and leak detection system for USTs in backup generator applications ATG & LEAK DETECTION SYSTEMS • Available in three models, TS2000/24, TS-2030/28, and TS-2000/32; each system monitors up to 8 USTs using magnetostrictive level probes (QCON) INTEWGENT CCNTROLSINC. • Monitors 2 or 4 tanks using magnetostrictive level probes • Includes 8 inputs for monitoring sump spaces, interstitial spaces and monitoring wells, using INCON's versatile selection of discriminating and nondiscriminating sensors • Third Party approved for volumetric tank tightness testing at a 0.1 gph leak rate and a 99.2% probability of detection *Third Party approved volumetric tank tightness testing ata 0.1 gph leak rate with a 99.5% probability of detection •Advanced RS-232 and RS-422 communications • Programmable schedule for inventory management reports and leak tests • Includes a 24 column thermal printer •Programmable &arm setup can tie any combination of alarms to output relays • Full featured RS-232 communications port with auto -dialing capability • Inhibits leak testing while the generator is running • Provides a "Run" report that documents generator run time, fuel usage, and fuel consumption rate • Dimensions: (H)1225" x(W) 10.25" x (0) 6.375" (H) 31.1 cmx(W)26.Ocm',xID) 16.2cm • Optional liquid monitoring in interstitial spaces and sumps with the model TS-2000/28 • optional vapor probe monitoring, with the model TS-2000/32 • Full alphanumeric LED display, 2 lines, 12 characters ' • Two alarm relay contact outputs • Dimensions: (HI 12.0" x IWI 16.0" x (DI 7.0'1 (H) 30.5 cm x (WI 40.6 cm'x (D)'17.8 cm PROBES & ACCESSORIES TSP-LL2 LIQUID LEVEL PROBE • State-of-the-art magnetostrictive level probe constructed of 316 stainless steel • Available in standard lengths for2' diameter to 12' diameter tanks. • Each probe is equipped with 5 thermistors to allow for true volumetric temperature compensation to API or custom tables • Provides level and volume information for both product and water • Compatible with a wide variety of petroleum products TSP-LL2C CHEMICAL PROBE • Magnetostrictive level probes for chemical applications • All wetted parts constructed'. of 316 stainless steel • Available in standard lengths for 2' diameter to 12' diameter tanks • Compatible with a wide variety of non -viscous chemicals • Intrinsically safe for Class I, Div. 1, Group D hazardous locations • Intrinsically safe for Class I, Division 1 Group D hazardous', locations TSP-K4A 4" RISER INSTALLATION KIT • Installation kit for installing the TSP-LL2 level probe in a 4" riser pipe • Includes a snap cap adapter for easy installation and removal of the TSP-LL2 level probe • Includes an epoxy pack and butt splice crimps for making watertight electrical connections • Helps isolate the level probe from the tank QI,[CONJ PROBES & ACCESSORIES TSP-IGF4 & TSP-IDF4 STANDARD FLOAT KITS TSP-SSP CHEMICAL FLOAT TSP-K4AS STAINLESS STEEL INSTALLATION KIT • Model TSP-IGF4 is the standard 4" float set for gasoline applications • Model TSP-IDF4 is the standard 4" float set for diesel, kerosene, and fuel oil applications • Each float set includes a product float and a water float ••316 stainless steel product float, 2.05' 0.D. • Suitable for use in'a wide variety of chemical applications • Consult factory for chemical compatibility issues • Installation kit for chemical applications • 4" NPTto 3/4" NPT reducing cap • Constructed of 316'stainless steel • The floats are constructed of nitrophyl and PVDF • The water float contains a nickel plated ballast • Compatible with a wide variety of petroleum products • Use one float per TSP-LL2C probe • Float specific gravity .55 to .63 • Collapse pressure 500 psig minimum • Contact factory with all chemical compatibility questions • Installs on a 4" riser pipe • Isolates probe head from exposure to the chemical ICON INTELLIGENT CONTR SING PROBE ACCESSORIES & SENSORS. TSP-IGF2 &TSP-IDF2 2" FLOAT KITS • Designed for use in applications involving 2" or 3" riser pipes • Model TSP-IGF2 is a 2.05" O.D. float set for gasoline applications • Model TSP-IDF2 is a 2.05" 0.11 float set for diesel, kerosene, TSP-ULS UNIVERSAL LIQUID SENSOR • tow.cost point liquid sensor • Easily installed in dispenser sumps, turbine sumps and piping sumps and fuel oil applications • Each float set contains a product float and a water float • The floats are constructed of nitrophyl • The water float includes a nickel plated ballast • Compatible with a wide variety of petroleum products • Monitors the interstitial space in • Supplied with a 25 feet of oil steel double wall tanks • Based on float switch technology • Made of chemically resistant material to assure chemical compatibility with most liquids resistant cable TSP-EIS ELECTRO-OPTIC LIQUID SENSOR • Electro-Optic liquid sensor for use in monitoring interstitial spaces in steel and fiberglass tanks • Supplied with 25 feet of oil resistant cable • Normally closed output circuit ensures that broken wires and similar failures won't go undetected • Sensor sends an alarm signal when the, prism comes in contact with liquid • Use the TSP-KI2 for installing in 2" riser pipes 5 CON] INTFI 1 I(lFNT fYINTrni CII�If" BR/TESENSORSTM TSP-DIS • Microprocessor based discriminating interstitial DISCRIMINATING BriteSensorsTMthatworks INTERSTITIAL SENSOR exclusively with TS-1000EF/ consoles DISCRIMINATING DISPENSER SUMP SENSOR DISCRIMINATING TURBINE SUMP SENSOR • Designed for use in interstitial spaces, sumps, or other locations where the presence of liquid indicates a leak • No expensive -plug in adapter modules required to connect it to the TS-1000EF1 system • Microprocessor based discriminating dispenser sump BriteSensorsTM that works exclusively with TS-1000EF1 consoles • Designed for use in monitoring dispenser and containment sumps • Generates three different alarms; water in the sump, hydrocarbon detected, and sump full • Uses an innovative polymer strip 'Microprocessor based discriminating turbine sump BriteSensorsTMthat works exclusively with TS-1000EF! consoles •,Provides reliable monitoring in turbine and containment sumps • Generates three different alarms; water in the sump, hydrocarbon detected, and sump full •'Uses an innovative polymer strip • Utilizes electro-optic', technology combined.with conductivity electrodes, to distinguish between product and water • BriteSensorstM communication is inherently fail-safe, since ali', wiring problems and faults with the sensor generate an alarm • Supplied with 25 feet of oil resistant cable to, detect hydrocarbons, and is reusable after exposure • No expensive-plugin adapter modules required to connect it to the TS-1000EFI system • BriteSensorsTm communication is inherently fail-safe, since all wiring problems and faults with the sensor generate an alarm • Supplied with 5 feet of oil resistant cable to detect hydrocarbons and is reusable after exposure • No expensive -plug in adapter modules required to connect it to the TS-1000EF1 console • BriteSensorslM communication is inherently fail-safe, since all wiring problems and faults with the sensor generate an alarm *Supplied with 5 feet of oil resistant cable ®CON) INTELLGENT CONTROL SING. 6 BR/TESENSORSTM TSP-DVS DISCRIMINATING VAPOR SENSOR • Microprocessor based discriminating vapor BriteSensorsTM for use in detecting hydrocarbon vapor in monitoring wells • Includes water detection capability to generate an alarm if the sensor is submerged in rising groundwater TSP-HIS HYDROSTATIC INTERSTITIAL SENSOR'. • Microprocessor based hydrostatic interstitial BriteSensorsTM for use in monitors. brine levels in double wall fiberglass tanks, • Generates a high brine or low brine alarm condition • Works exclusively with. TS-1000EF1 consoles • No expensive -plug in adapter modules required to connect it to the TS-1000EFi system • BriteSensorsTM communication isinherently fail-safe, since all wiring problems and sensor faults generate an alarm • Works exclusively with TS-1000EFIconsoles No expensive -plug in adapter modules required to connect it to the TS-1 000EFI system • BriteSensorsTM.communication is inherently fail-safe, since all wiring problems and sensor faults generate an alarm • Reusable after exposure to 'I hydrocarbons • Supplied with', 20 feet of oil resistant cable • Uses the TSP-KW4 installation kit when installed in 4 monitoring wells • Supplied with 15 feet resistant cable' of oil • Uses the TSP-KV4 installation kit when installed in 4" reservoir openings. CONJ SENSORS HIGH LEVEL SENSOR DISCRIMINATING GROUNDWATER SENSOR UNI-STRUTTM MOUNTING KIT • The TSP-HLS is an overfill prevention level switch • The TSP-HLST is an overfill prevention level switch, with a built-in self -checking feature • 'The float switch assembly is made of chemically resistant materials to assure compatibility with most petroleum products • Works exclusively with TS- 1000EF1 consoles • Generates an alarm indicating that the groundwater level has dropped below the bottom of the sensor • Microprocessor based sensor detects the presence of hydrocarbons floating on groundwater 1 ICON INTEWGENT CONTROL SING. • Installation kitfor mounting TSP-DDS and TSP-DTS in sump spaces • Easily customized to fit virtually any sump by cutting the Uni-strutTM assembly to desired length • Level switches are available in 15" and 30" adjustablelengths • .Normally closed output circuit ensures that broken wires and similar failures won't go undetected • Installs into the storage tank via a 2" NPT fitting mounted on the sensor shaft • No expensive plug-in adapter modules required to connect it to the TS-1000EF1 system • BriteSensorsTM communication is inherently fail-safe, since all wiring problems and faults', with the sensor generate an alarm, • Supplied with 5 feet of oil resistant cable and installation kit for 4" monitoring wells • Provided with 2", 3 and 4" pipe clamps, for mounting to sump piping • Sensor location is easily adjusted by the unique sliding feature of the Uni- strut assembly SENSOR ACCESSORIES TSP-Kl2 INTERSTITIAL SENSOR RISER CAP KIT • Installation kit for installing the TSP-DIS, TSP-EIS or TSP- ULS in dry interstitial spaces. with 2" riser pipe openings • Supplied with,a cord grip and butt splices for wiring connections • Easily installs into a 2" riser pipe with a compression fit against the wall of the pipe • Provided with security holes that fit a padlock to prevent unauthor- ized access into the riser pipe TSP-KV4 HYDROSTATIC SENSOR VENTED RISER CAP KIT •Vented installation kitthat mounts a TSP-HIS sensor into a 4" reservoir opening on double' wall fiberglass tanks • Supplied with a cord grip and butt splices for wiring connections • The riser cap is a compression fit into a 4" riser pipe via the use of a lever • Provided with security holes that fit a padlock to prevent unauthor- ized access into the riser pipe TSP-KW4 MONITORING WELL CAP KIT • Installation kit for mounting the TSP-DVS vapor sensor in a 4" monitoring well • The monitoring well cap is a compression fit into the well pipe via the use of a lever • Supplied with a cord grip and butt splices for wiring. connections • Provided with' security holes that fit a padlock to prevent unauthor- ized access into theriser pipe 5 9 OECONj rnrrm i ,r Nlm r nr, rrory c!Nu- BRITEBOX MODULES BriteBoxTM INSTALLATION KIT EXPANSION RELAY MODULE SENSOR EXPANSION MODULE • Installation kitthat provides a convenient method of connecting a TS-CIM, TS-ROM 1, TS-ROM2, BriteBoxT'"to a TS-1000 series console • Allows mounting the BriteBoxesim within 18" of the TS-1000 console • Expansion relay module exclusively for use with the TS-2000/32 ATG system. • Adds eight additional relay outputs to the TS-2000/32 system • The module uses miniature electromechanical relays, rated 3 amps at 120 VAC • Eight input sensor expansion module used to interface with all TS-1000EFIconsoles • Up to two TS-SEMs can be connected to a TS-1000EF1 console, increasing the total number of sensor inputs to a maximum of 24. • The installation kit includes an 18"piece of flexible conduit, (with connectors)' ribbon cable, and instructions • Allows the TS-2000/32 to disable pumps, operate indicator lights, sound alarms and perform other control functions in response to alarm conditions • Works with all standard and BriteSensorsm sensors • The TS-SEM communicates with the TS-1000EF1 over INCON's BriteBusTM • Use theTS-KB installation kitto connecttheTS-SEM interface cable to the TS-1000EF! console II CONJ INTELLIGENT CONTROLSINC 10 BRITEBOX MODULES CONTROL INPUT MODULE • Can be used with the TS-1000/2G ATG console in backup diesel generator applications • Accepts a generator run signal • that allows ATG to inhibit leak tests while the generator is running • Accepts alarm and control signals from other systems and devices that can be used to generate corresponding alarms in the TS-1000 system • Optionally equipped with up to 8 optically isolated plug-in modules • Input modules available in 3.3- 32 VDC, 18-60 VDC, and 90- 120 VAC ranges TS-ROM1 • •Available with either 4 or 8 optically isolated solid state PUMP DISABLE MODULE relays • Economical solution for • Interfaces with all TS-1000 disabling pumps or dispensers series consoles in the event of an alarm condition • Each TS-ROM1 output channel can switch a 1 amp 120/240 VAC load -Th44 'UMTq TS-ROM2 RELAY OUTPUT MODULE • General purpose low cost relay output module used to operate indicator lights, sound alamis, or to provide dry contact closure for remote monitoring equipment • Interfaces with all TS-1000 series consoles • Uses miniature electro- mechanical relays to switch external loads • Available in a 4 or 8 relay output configuration RE'maimiir • Each TS-R0M2 output channel can switch a 3 amp 120/240 VAC load =CON INTELLIGENT CO4TRCAL—INE-7. SYSTEM ACCESSORIES & SOFTWARE REMOTE OVERFILL ALARM REMOTE OVERFILL ALARM ALARM ACKNOWLEDGE UNIT 4 /iu�;M 6v E HFlu ALAPM NC✓NOWLEDGF • Low intensity remote audible and visual alarm unit for use with all Tank Sentinel® consoles t Features a pulsating orange light and piezoelectric buzzer to warn of alarm conditions • Produces a sound level of 85dB at 10 feet •,High intensity remote audible and visible alarm unit for use with all Tank Sentinel® consoles • Features a pulsating white strobe light and high intensity buzzer to warn of alarm conditions • Produces a sound level of 95dB at 10 feet • Remote alarm acknowledge unit for use with all Tank Sentinel® consoles equipped with model TS-RA1 and TS-RA2 remote alarm units • Provides for a convenient method of remotely silencing overfill alarms •, Housed in a rugged nonmetallic NEMA 4X en -closure suitable for outdoor applications •.For remote silencing. applications, use in conjunction with the optional TS-RK remote alarm acknowledge unit • Housed in a rugged NEMA 4 enclosure suitable for outdoor applications • For remote silencing applications, use in conjunction with the optional TS-RK remote alarm acknowledge unit • Housed in a rugged nonmetallic NEMA 4X enclosure suitable for outdoor applications • Typically installed outdoors near the tanks when used as part of an overfill alarm system II CON INTELLIGENT CONTROLsINc 12 SYSTEM ACCESSORIES & SOFTWARE TS-HOST UST MANAGEMENT SOFTWARE • Remote communication software package for use with all Tank Sentinel® automatic tank gauges • Uses xBASE compatible files INFORMATION LOGGING PROGRAM • Allows unattended polling of remote Tank Sentinel® ATG's and collection of information ATG MODEM KIT • 2400 baud ATG modem used for remote communi- cations,between Tank Sentinel® ATG's and an IBM® compatible PC • Allows complete remote programming and operation of Tank Sentinel® ATG's • Program allows any IBM PC or compatible, to act as a powerful console for a virtually unlimited number of Tank Sentinel® ATG's • Reports may be displayed, printed or written to a disk file • Companion program to the TS-Host remote communication and UST management software program • The program has the flexibility to create a custom schedule of calls at specified dates and times • Records data in xBASE compatible files • Meets the V.22 standard at 2400 baud • Connects directly to the RS-232 serial port on all Tank Sentinel® consoles • Includes RS-232 cable, 7 foot telephone cord, and 120 VAC power pack TS-HOST, T54OG .1 13 [CON inrrri ir_nir r-rv.rror,i c!Nir SYSTEM ACCESSORIES & SOFTWARE ELECTRONIC LINE LEAK DETECTOR •Stand-alone electronic line leak detector monitors under- ground piping systems with submersible pumps in fuel dispensing applications TANK GAUGE INTERFACE • Easily retrofits into the existing mechanical line leak detector port on most submersible pumps • Absolutely no excavation, conduit, or wiring required to install the system between the pump and station • 'Installs without breaking into the piping system • Lowestinstallation cost of all electronic line leak detectors on the market • Automatically shuts down the submersible pump in the event that the TS-LLD fails a line leak test • ATG interface module that provides a four wire RS-485 communication link, when connecting up to 8 TS-LLD's to a. Tank Sentinel® console • The ATG interface gives the Tank Sentinel® console the ability to print out hard copies of Fine leak test reports • An LED display at the control unit provides an ind cation on how many days it has been since the system last passed a 0.2 gph monthly line leak', test • Optionally interfaces with the Tank Sentinel®ATG's,using the TS-TGI interface module • Based on volumetric flow technology • Third Party approved for EPA required 3.0 gph hourly, 0.2 gph monthly, and 0.1 gph annual line leak tests in 350 feet of 3" piping • Conveniently plugs into the existing serial port on the Tank Sentinel® console • Allows the Tank Sentinel console and the TS-LLD control unit to be separated by up to a 1000 foot cable run =► CONJ INTELLIGENT CONTROLSINC 14 LITERATURE ORDER FORM CONTACT: COMPANY NAME; SHIPPING ADDRESS: PHONE NUMBER: Part Name. Literature# TS-1000EFI 000-1261 TS-1000/0 EFI 000-1241 TS-1000/2 EFI 000-1237 TS-1000/4 EFl 000-1238 TS-1000/2G EFI 000-1250 TS-2000 000-1222 TS-2000/24 000-1224 TS-2000/28 000-1225 TS-2000/32 000-1226 TSP-LL2 000-1227 TSP-LL2C 000-1267 TSP-K4A 000-1228 TSP-K4AS 000-1266 TS-HOST 000.1230 TS-LOG 000-1231 TS-M 000-1232 TS-ROM 1 000-1243 TS-ROM2 000-1248 TS-LLD 000-1262 TS-TGI 000-1263 Part Name Literature # Float Set 000-1264 I TS-ER 000-1038 TS-RA1. 000-1245 TS-RA2 000-1246 TS-RK 000-1247 TS-CIM 000-1249 TSP-DVS 000-1252 TSP-EIS 000.1253 TSP-ULS 000-1254 TSP-HLS 000-1255 TSP-DDS 000-1256 TSP-DTS 000-1257 TSP-DIS 000-1258 TSP-HIS 000-1259 TSP-MWS 000-1260 TS-KB 000-1338 TSP-KS 000-1355 TS-SEM 000-1265 Tank Sentinel Product Brochure 000-1483 For more information, fax or mail requests to: =coN1 INTELWGENT CONTROLS, INC. P.O. Box 638 • Saco, ME 04072 800-872-3455 / Fax: 207-283-0158 (Attention: INCONLSales Department) al CO NI! INTELLIGENT CONTROLS,INC P.O. BOX 638, SACO, MAINE 04072 USA 800-872-3455 / 207-283-0156 FAX: 207-283-0158 p \\ ® -yb ° 2E /0 vn . \ . 0 L 2 T11�• to coo TSP-u-LS O a.• nm Tya ThcntJ TSP- L-L - 1I' Mai PRoB6 OY SAP 301102 M. can 14 Gvai WO s 1 *y um!'_t tr f M• II.� Mr • 1. aLAv. >w, a vin � P1•f CI T )Y• dein vow 11M1 • -5 Sersor ehitc+ Po6< LE rtoL +.0 D1eon Pa k TS 20c L6C.liII •ICC .,aam: 1 LA 1210413 f.Sa a. LA 3 )101.4 14•2 1an1 MAN. ICU v, U. Ln-a>a u a..P1af f U. 11304 10• lLK YK PICK 4 U. W1 Inc Mot 500216' 4 to 1.1-3 1•K SAP SCR n» n1 lone ar. nq-w-a Ma Part w Rena vwr Oa nt MMt ALICE1 101 Inc rroe num aL t{na UAL FAO COSM. 9' IC 11• wan MAC SC *4 am1 mtvem 1R • OISC rw a Im no Coa.Pas Pa awn a alum .art. 22•0120242 111-111 LS-3 2 nee 2100C sr3u-a falbanit I. au 13Q 1g12210t AFL fan L9V.Oa I.O pnmr-T POoo( COCIUTO4 tuS n gull X L�Kc® a 11MAn M. WPM PLOT wrti SC ATS MO 00411 arse 3 TDC3 Si cat n¢ .r..11ano..a a Mum 010•I2 1101121 a ' 01A•042t) 110 IC LCCL12 11 Cama. SOat S E CICSLCAL MSC& u taDtolr ralom no -.mac 1t .ICONS,(A MSC COMU CIOC R =1St& Can aCaL KUOK LP.... OLQ..Mr I1.2•4240 Al2 PeIMLO K,C2"1ick canna. II-2 GO I SITC.1 conw..M( '.. c co.(cna an L•( (AO.) a to saa/O•iame LOML �. as rnca nu. M) n4Luc.. IttCel = asr SY11 OMIIRM0113 Dam a, PM — el_a J.L PEPOR fl nsoca%a PC CC•atali NOS De m f.A.ws $fr•Pd ••••••t e.+••• lea EIMPLX Fuel Supply Systems Packaged Pump Sets Packaged as a pre-engineered, integrated system of pumps, pump drivers, controls and accessories, pre -plumbed and pre -wired, SIMPLEX PACKAGED PUMP SETS provide the user with the reliability of job engineered and system matched components and factory assembled systems. These pump sets are intended for use with fuel oil, lube oil (class II or class III combustible liquids having a flash point of 100°F or higher) or water. Simplex SPS Series Packaged Pump Sets are totally enclosed units suitable for wall or pad mounting. All devices, wiring and plumbing are contained within the weatherproof enclosure. Isolated compartments are provided for mechanical and electrical devices. External ports are provided for connection offield plumbing. The enclosures include an integral catch basin with leak detector. Three models/sizes are available spanning from 2gpm through 25gpm, simplex, duplex, triplex or quadplex pumps; 0.33 through Shp. Full system integra- tion of pumps, starters, controls, tank monitors, tank level controls, external alarm panels is provided.', Simplex is a manufacturer of fuel supply systems and products for electric power generation. In the SPS Series, Simplex has focused its unique skills and talents as both tank manufacturer and electronics manufacturer. The scope of Simplex products and experience includes AC power distribution and control, power generation test equipment, engine control, automatic tank systems, pumping systems, fabrication and manufacture of UL142 aboveground tanks, containments. Simplex is an engineered product specialist, a designer of solutions through creative application of a wide range of standard products. Simplex is a family owned and operated business that has been active and leading in its specialized fieldfor more than 60 years. Features System engineered, integrated function packages • NEMA3R weatherproof enclosure • Wall or pad mountable • Segregated electrical/mechanical compartments within enclosure • Enclosure diip pan and leak de- tector • Pump disconnect circuit upon leak detection • Inlet, outlet and pressure relief manifolds • Fuel connections made to fittings in sidewalls • High performance hydraulic gear pumps , • Pressure relief valve supplied stan- dard, external port for relief to tank • Pump shutoffs', supplied standard • Industrial motors • Motor starter with overload relay and disconnect supplied standard • Disconnect switch handleinter- locked with hinged door • Simplex, duplex, triplex, quadplex pumps available • Automatic duplex pump control- lers available • 'Tank Commander" tank monitors,' level controllers, annunciators, fill panels, overfill panels, available as options • Simplex Packaged Day Tanks and'. Reliable Fuel Supply Systems can be engineered as systems with SPS Packaged Pump Sets Simplex, Inc., 1139 North MacArthur Boulevard Springfield, Illinois 62702 217-525-6995 24 hr. 217-528-3130 4A51189A ® 1993 All Rights Reserved Design subject to change without notice • • Fax 217-525.7984 Printed in the USA STANDARD MODELS See option list for application to specific,models. SPS-10 Basic single pump unit to 10 gpm, 1.0 hp. Limited options/option combinations —see option ,list's "Application Code" on pages 6 & 7. PUMP RANGE MOTOR RANGE SPS-20, SPS-20 DX 2,7,10 GPM 0.33, 0.50, 0.75, 1.0 HP Intermediate duty unit to accomodate single or duplex pumps to 17gpm, 2.0 hp. SPS-20DXincludes automatic duplex pump controller and duplex pumps as specified. Most options available, some limitations in com- binations of options —see option list's "Application Code" on pages 6and 7. PUMP RANGE 2, 7, 10, 17 GPM MOTOR RANGE 0.33, 0.50, 0.75, 1.0, 1.5, 2.0 HP SPS-30, SPS-30DX Full capability unit to accomodate any combination of controllers and single, duplex, triplex pumps listed herein to 25 gpm, 5.0 hp. Quadplex combinations also available depend- ing on options selected. SPS-30DX includes automatic duplex pump controller and duplex pumps as specified.. All options/option combi- nations available —see pages 6 & 7. PUMP RANGE. MOTOR RANGE 2, 7, 10, 17, 25 GPM 0.33, 0.50, 0.75, 1.0,.1.5, 2.0 HP Standard Equipment SPS-10 • Single pump/motor, select from pages 4 and 5 • Pump pressure relief valve • Pump inlet and outlet shutoff valves • Pump motor starter with overload relay and disconnect switch with door handle interlock • Unit leak detector, interlocked with motor starter, remote indication contacts SPS-20 • Single'pump/motor, select from pages 4 and 5 • Pump pressure relief valve • Pump inlet and outlet shutoff valves • Pump motor starter with overload relay and disconnect switch with door handle interlock • Unit leak detector; interlocked with motor starter, remote indication contacts SPS-20 DX • Duplex pump/motors, select from pages 4 and 5 • Pump pressure relief valve (2) • Pump inlet and outlet shutoff valves, each pump • Pump motor starter with' overload' relay, each pump • System disconnect switch with door handle interlock. • Unit leak detector, interlocked with'. motor starters, remote indication' contacts SPS-30 • Single pump/motor, select from pages 4 and 5 • Pump pressure relief valve (2) • Pump inlet and outlet shutoff valves • Pump motor starter with' overload relay and disconnect switch with door handle interlock • Unit leak detector, interlocked with motor starter, remote indication contacts SPS-30 DX • Duplex pump/motors, select from pages 4 and 5 • Pump pressure relief valve'. • Pump inlet and outlet shutoff valves, each pump • Pump motor starter with overload relay, each pump • System disconnect switch with door handle interlock • Unit leak detector, interlocked with motor starters, remote indication contacts Simplex, Inc., 1139 North MacArthur Boulevard Springfield, Illinois 62702 217-525-6995 24 hr. 217-528-3130: Fax 2177525-7984 4A51189A ®1993 All Rights Reserved Design subject to change without notice Printed in the USA • SUPER-XLTM .PUMP The Simplex SUPER-XLTM is a high technology hydraulic pump featuring pressure -loaded, self -compensating gears and a mechanical shaft seal. The,SUPER-XLTM is the standard pump used in a Simplex Packaged. Design Day Tanks and Pump Sets and is avail- able in 2-25 GPM capacity range. PUMP MODEL DISPLACEMENT 'IN' (CC/REV.) Flow, GPM, LPM RPM 100 PSI 1000 P51 1500 PSI 2000 PSI 2500 PSI (6.9 Bar) (69 Bar) (103 Bar) (138 Bar) (172 Bar) SUPER XL- 11 .225(4.18) 1800 1' .99 1.86 1.79 ' 1.73 . 1.66 (7.54) (7.05) (6.78) ' (6.56) (6.29). SUPER XL-39 .91(14.92) 1800 7.08 6.87. 6.77 6.66 6.56 (25.66) (25.24) (24.86 (26.83) (26.04) SUPER XL-62 142(23.28) 1800 11,10 10.81 10.70 10.60 10.40 (42.07) (40.97) (40.55) (40.17) (39.42) SUPER XL-90 2.15 (35.250 1800 16.70 16.50 16.30 (63.29) (62.54) (61.78) SUPER XL-114 3.25(53.28) 1800 251,30 24.90 24.60 24.40 (96..89) (94.37) (93.23) (92.48) The. Simplex TANK electronic liquid let sensing, indication, #51011. 4 Simplex. Inc., • • • • • • Features • Pressure loaded des gn Efficient, simple design -few moving parts Exceptionally compact and light- weight for their capacity Efficient at high pressure operation Resistant to cavitation effects High tolerance to, system contamina- tion Reliable under cold weather opera-'. tion Sleeve bearing construction Multi -fluid compatibility DUPLEX PUMP SYSTEMS Multi -function duplex pump control- ler system providing selectable oper- ating modes including: Control from remote contacts: pumps stop, lead pump start; low level (lag pump. start) • Automatic lead,pump alternating with automatic lag .pump back-up ,• Manual lead pump selection,'. automatic alternating, automatic lag. pump back-up • Automatic twin pump operation. (both pumps run simultaneously), ' automatic level control back-up'.. • Manual operation • Mode selector switch • Pump running indicators for each '. pump TC-5 Features • Tank mounting capacitance probe sensor • Interconnected via;a 3-wire cable • Direct reading electric level gauge • High and low level and tank rupture alarms/relays • Pump/valve control differential output relay • Pump/valve control switch, test push- button • High level cutout and tank rupture.. cutout • Power available and tank filling indicators • Not -in -auto alarm • Relay outputs 1'139 North MacArthur Boulevard Springfield, Illinois 62702 217-525-6995 24 hr. 217-528-3130 Fax 217-525-7984 4A51189A © 1993. All Rights Reserved Design subject to change without notice ,Printed in the USA TANK COMMANDER. COMMANDER TC-5 is an integrated design, •el indicator and'controller which incorporates pump/calve level -control and alarms.: See Bulletin MOTORS FOR PUMP DRIVE All motors are continuous duty, 40° C, UL Recognized SINGLE PHASE MOTORS _THREE PHASE MOTORS Split Phase Star, Dripproof, Rigid', Base, Class Insulation, Dripproof, Rigid Base, Class B Insulation, NEMA B, High Moderate Startii g Torque, Sleeve Bearing Starting Torque,Ball Bearing HP RPM Voltage NEMA Frame Basting Thermal Prot' ' Saralee Factor - Approx. F.L Amps 113 1800 115 48 Sleeve Auto 1.0 6.6 12 1800 115 56 Sleeve None 10 9.2 Capacitor Start, Dripproof, Rigid Base, Class B Insulation, Moderate Starti zg Torque, Sleeve Bean 2g ' HP. RPM Voltage NEMA Frame Bearing Thermal Prot. Service Fame Approx.. F.L Amps 1/3 I800. 115/230 46 Shave Auto 10 t2 1800 115/230 56 Sleeve Auto 1.0 9.2/4.6 3/4 ' 1600 115/230 56 Sleeve Auto 1.0 10.4/5.2 Capacitor Start„ Dripproof, Rigid Base, Class B Insulation, High Starting Torque, Ball Bearing HP RPM ' Voltage NEMA Frame Thermal' Prot • Servlee. Factor . Appros. F.L. Amps 1800 115/208.230 56 Auto 1.15 13.4/6.6-6.7 1 1/2 1800. 115/206-230 56H Auto 1.15 18.0/9.3-9.0 2 1800 • 115/208-230 145T None 1.15 210113-105 3 1800 115/208-230 104T None , 1.15 33.0/16.5 5 1800 208-230 164T None ' 1.15 230-21.0 71/2 • 1800 208-230 215T None 1.15 35.2 Capacitor Start,; Totally Enclosed, Fan -Cooled, Rigid Base, Class B Insulation, NEMA-1, ('- 1.0 HP) High Starting Torque, Ball Bearing HP RPM'': Voltage NEMA Frame Thermal,' . ProL '.' Service Factor Approx. F.L Amps 1/3 1800, 115/208230 56 Auto 1.15 6.6/3.1-3.3 12 1800 1151208.230 56 Atom . 1.15 8.8/4.2-44 3/4' 1800 115200230 55 Auto 1.15 110/5.46.5 1800 115208230 56 Auto 1 15 13.4/6.8-6.7 11/2 1000' 115206-230 56H Auto 1.15 15.2/82-7.6 2 1600 115/208-230 145T None 1.15 16.89A, 3 1600 115/208230 184T None 10 34.0/17.0 5 1800' 308230 2131 None i 10 27.536.0 712 • 1800 200.230 215T None. 16 36.5-33.0 HP ` RPM Voltage NENA Frame Thermal Prot. Service Factor ApProa. F.L Amps,''. 1/3 1800 200-230/480 56 Auto 135 151610.0'. 1/2 1800 200030/460 56 Auto 1:35 2324/1.2'i Y4 1800 200.230/460 '- 56 Auto 1.25 29.30/1.5, 1800 208.230/460 56 Auto 1.15 3.5.36/10.. I12 1600 200230/460 I45T Auto 1.15 4.8-482.4'., 2 1800 208 230/460 145T Auto 1.15 I 6.2.62/3.1 3 1800 200230'460 I45T Auto 1.15 92-8.642. 5 1800 '.230/460 1841 Auto 1 15 133/6.6 71/7 1000 230,460 213T Auto 115 20.0/10.0'. 10 1800 230'460 215T Auto 1.15 266/13.3'.': Totally Enclosed -Fan -Cooled, Rigid Base, Class B'Insulation, Class F (I82T -2547), NEMA B, High Starting Torque HP RPM Voltage NEMA Frame I Approx. EL Amps I/O 1800 208-230/460 56 1.5-1.6/0.8 1/2 1800 208-230/460 . 56, 2.3-2.4/1.2 3/4 1800 208-230/460 56 2.9-3.0/1.5 1 1800 208-230/460 56 ' 3.5-3.6/1,8 1 1/2 1800 208-230/460 145T 4.8-4.82.4 2 1800 208-230/460 145T ' 6.0-5.82.9 3 1800 208-230/460 145T ' 8.6/4.3 5 1800 230/460 184T 14.0-13.2/6.6 7 1/2 1800. 230/460 2137 21 0-30.0/10.0 10 1800 230/460 2157 I 28.0.270/13.5 Simplex, Inc., 1139 North MacArthu Boulevard Springfield, Illinois 62702 ' 217-525-6995 24 hr. 217-528-3130 4A51189AC 1993 AJI Rights Reserved Design subject to change without notice Fax 217-525-7984', Printed in the USA APPLICATION CODE: X= Available option 0= Not available this line Application Code Option BMW sn-2°sva.3n Description Mechanical Options 010 X X X Auxiliary hand pump; piston type, 1 GPM capacity. Self -primes to 6 meters (20 feet) of lift. Includes hand pump check valve. 3/8" NPT (Side mounted). 015. X X X Auxiliary hand pump, piston type. 20 gallons per 100 strokes. Self -primes to 6 meters (20 feet) of lift. Includes hand pump check valve. 1" NPT (Side mounted). 060 X X X Fuel Strainer for use with standard 2 GPM pump. Ya" NPT (Shipped loose mounts in day tank intake line). 061 X X X As 060, except for use with 10 GPM - 25 GPM pumps. 1" NPT (Shipped loose -mounts in day tank intake line.) 070 X X X Priming tee and check valve assembly, consisting of pump priming tee, fuel line priming tee land check valve. Two included with option 345, duplex system. a) 1" NPT, for use with standard 2 GPM pump b) 3/4" NPT, for use with options 7, 10, 17 GPM pumps c) 1" NPT d) 1 Y" NPT, for use with 25 GPM pump X X Solenoid valve on pump intake to prevent loss of pump prime or tank flooding. For AC systems. Specify voltage. (Two required if ordered with duplex pump options). a) Y2" NPT, for use with standard 2 GPM pump b) 'h" NPT c) 3/4" NPT, for use with 7, 10, 17 GPM pumps d) 1" NPT e) VA" NPT, for use with 25 GPM pump f) 2" NPT 083 . X X ' X Solenoid valve, as above, for DC systems.Specify voltage. a) 'h"NPT b) 3/a"NPT 087 X X X Manual fuel cut-oftvalve on day tank fuel inlet for gravity fed:day tanks, shipped loose. (1/2" NPT) 088 X X X Manual fuel cut-off valve, as above. (1" NPT) 090 X, X X Foot valve to prevent loss of pump prime, shipped loose. (1" NPT) 080 X. 093 X X X Fusible link valve, self -closing when acted upon by 165°F or greater. Supplied loose for remote installation. (1" NPT) 095 X X X Pressure relief valve. a) For use with standard 2 GPM pump b) For use with 7 GPM pump c) For use with 10IGPM, 17 GPM, 25 GPM pumps 100 X X X Pressure gauge, installed on pump outlet. 101, X X X Vacuum gauge, installed on pump inlet. 102 0 X 0 Compound gauge, installed across pump or strainer. 103 O X O Flow gauge, in line with pump, to 30 GPM. 120 X X X Extra 1" NPT pipe, connections on tank (specify quantity, location and use). 1139 North MacArthur Boulevard Springfield, Illinois 82702, 217-525-6995 24 hr. 217-528-3130 Fax 217-525-7984 4A51189A 01993, All Rights Reserved Designsubject to change without notice ,Printed in the USA APPLICATION CODE: X= Available option 0= Not available this line OPTIONS Application Code Option ss10sP530sP3]0 Description 140- X X, X Special, non-standard paint color. Tinting of ,our standard latex or enamel paints only. See below for optional coatings. 141 X X X Epoxy primer, polyurethane finish exterior coating option included. a) 10-100 gallon models b) 150-600gallon, models ' c) 800-2500 gallon. Specify color. Double price when overflow basin 142 X X Inorganic zinc primer, epoxy finish exterior coating. Specify color. Double price when overflow basin option included. a) 10-100. gallon models b) 150-600 gallon models c) 800-2500 gallon models Electrical Options 250 0 X X Tank Commander TC-4 Tank Monitor. See ,Bulletin #51012. 251 0 X X Tank Commander TC-5 Level Controller. See Bulletin#51011. 261 X X X "On -Off" day tank system circuit breaker with short circuit trips. Mounted on day tank. a) For use with standard and optional single-phase, AC motors; DC motors b) For use with optional 3-phase, AC motors 262 0 X O 50VA, 480/240: 120, 1-phase, control power transformer 285 0. X X 334 X X X 345 0 X X Loss of flow alarm. Sensor detects fuel flow from pump and activates alarm if flow is lost while pump) is running. Adjustable sensitivity and time delay. Alarm horn installed on day tank . Multi -function duplex pump controller system providing selectable operating modes,' including: • Automatic lead pump alternating with automatic lag pump back-up • Manual lead ,pump selection, automatic alternating, automatic lag pump back-up • Automatic twin pump operation (both pumps run simultaneously), automatic level control back-up • Manual operation. Basic System includes the following: • Mode selector switch • Pump running indicators for each pump • Two 1/3 HP;',120 V, 2 GPM pumps, each with check valves., 346 0 X X Two running time meters, one for each pump. 396 0 X X Radiator with electric fan, flow switch, installed and wired. Important Note: This system shall be for use with fuel oil as described by NFPA321, "Basic Classification of Flammable and Combustible Liquids Code" As defined by these standards, the fuel supply system shall be for use with combustible liquids," those having a flashpoint at or above 100°F and further defined as Class II or Class Ill liquids. In no case shall a liquid having a flashpoint less than I00°F be used. In every case, the system shall not be used or applied at a temperature in excess of the flash point of the contents'Electrical' equipment used in the system shall be in accordance with NFPA30, section 5-7, wherein it states '_For areas where Class 1I or Class III liquids'' only are stored or handled at a temperature below their flashpoints, the electrical equipment may be installed in accordance with provisions ofNFPA70, National Electrical Code,° forxordinatylocations...' NOT FOR USE WITH GASOLINE..,, Simplex, Inc , 1139 North MacArthur Boulevard Springfield, Illinois 62702 217-525-6995 24 hr. 217-528-3130 Fax 217.525.7984 4A51189A 49 1993 All Rights Reserved Design subject to change without notice Printed in the USA MEMBER �PEI Simplex, Inc-; 14.1.1012 C. WOO SPS-10 TOP VIEW LESS 000R picnic SulFW N ENCLOSURE SHOWN LESS 000R FRONT VIEW SPS-20, SPS-20 DX ISO ENCLOSURE SHOWN LESS 000RS SPS-30, SPS-30DX u,E %ea I. ENCLOSURE 0(03 S P00000 MO PYNN EO z 00(Y O SO ('92R ' 3. U. PHIS LUMN IMICµ 4. ParsMWSr0. E EMRO. OR. 0x0 03110 CLEANER Y M05PW02E0 nET 32.3 RIGHT SIDE VIEW RIGHT SIDE VIEW man , �.. 00D .,0( 1.1441•1 1139 North MacArthur Boulevard Springfield, Illinols 62702! 217-525-6995 24 hr. 217-528-3130 Fax 217-52517984 4A51189A 01993 All Rights Reserved Design subject to change without notice Printed In the USA 91MIPDC TO' 1139 N. MacArthur Bfvd, 6prh1gfleld, IL 62702' (2i7) 6254995, Fax (217) 525-7984 Contact Quotation: Fuel Supply Systems Date Quotation # Customer Ref °Original Quote QConflrming w/ CIQuoted as Below QQuoted to Spec. Delivery: Drawings ...4,-;--Weeks after receipt of order Equipment ?as2 weak; after, dwg. approval BY a� SeofquWWreeslistSr c lezInc:stenn,ardwn2Sa* aDCOO 0IN. Subject to Simplex;Stsndard CordCaw of Sale andWarranty, 4A2t1S4A, 02555A. Attached Tenet Nat 30 Days wl 1.5% per northaaMoo derma afar 30 days. tor open account aatomen only. Speinpfleid. twnds (Customer pays Etl height charges) ATTENTION: PH FAX MODEL S PS -.10-5:0-S1rS PACKAGED PUMP SET, as follows ITEM- 7 Effective 60 days Date FOB poinb Skin PuhpsET FoP-3 FOP- Li, Boilers Standard Standard Equipment Nate: Ail base prices include stapdard 2GPM,'aHP, 115VAC pumps. Add opecnal pampa and motors to these base prtces as required. All SPS Pump Sets Include containment sump with teak sensor: -B8 (Baslo-8ingls Pump) *Standard 2GPM,"aHP, 115VAC pump.'I.. -SS (SuperSingle Pump) • Standard 2GPM.'mHP, 115VAC purigt • Option 260;, door mounted dsconners awttct with interlock • Option 767 or 768, single-phase starter vita con wired to .. terminal Clock • (2) Option 088, 1 • shut -offs on Inlet and outlet • Option 0135; pressure raid valve • Option tt70, 1' check valve -BD (Basle -Duplex Pump) • DUPLEX Standard 2GPM, 'aHP, 115VAC.pump • Option 345, automatic duplex pump contofer • (2) Option 070, 1' check vetve QUANTITY: 3 Ch;l%rs Supp5' -SD (Super•Duplex Pump) • DUPLEX Standard 2GPM, 'SIP, 115VAC pump • Option 345, autxnadc duplex pump cotdtoller, • (2) Option 070, 1' died( valve • OptIori 280, door mounted disconnect twitch vtith Interlock • Option 768, s a -phase starters • (4) Option 086, 1 • clef-ofla on Mkt and outlet • (2) Option 095, pressure relief valve Speo cations • Duplex Pump.) • DUPLE(. Standard 2GP%4,'o}PP, 115VAC pump. • Option 345, cute hs duplex pump Oontroller • (2) Option 070, 1' check valve • Option 260, door mounted dlsoonnectewttch w1th Intotic& • Option 768, tangle -phase starters !; • (4) Option On, 1' shut en idet and outlet (2) Option 096, pressers relief valve • (2) Option oeo, Nei strainer • (2) Option 102, compound gauge on each pump Inlet wNA shut-off • (2) Option 102, compound gauge on each pump Oldie. With ahut'atf • (2) Option 285. toss of flow alarming pump salivate • AAeotil7-22508 a, .Ow MECHANICALOPTSONS 010 Auxiliary Bend pump ....-__.__...._._--.-•_._- Auxiliary hand pump Fuel strainer Fuel strainer -.. Duplex strainer a)1'NPT bJ 11/2' NPT.... :...... .....:.._._._, .._ _...___...._._.., c) 2' NPT Check valve/priming tee assembly c) 1'NPT W- d)1 P. for 25GPM. Solenoid valve. a) y,'NPT for 2 GPM c) 34' NPT for 7/10/17GPM d) 1' NPT • a) 114' NPT tar 25GPM I)2' DCSclenold Valve a) h' NPT b) 9d' NPT_...:-.__..._._._.__................'..._.__...... _ 087 Manual fuel cutoff valve _ a)'h'NPT.bronze....,.... ._.......... _-__ ___..-_......., b) 3'N PT. bronze c) 15'N PT. ere rated _ d) k.'NPT, fire rated $� 08a Manual fuel wtoff valve a) 1 'NPT, bronze b) 2'NPT', bronze c) 1'NPT„ are rated .. —. d) 2'NPT. fire rated 093 Fusible link valve a)1'NPT b) 2'NET 095 Pressure rake( valve a) fort GPM Sr" STD 2 2 015 060 061 062 070 080 083 104 140 141 b)tor7GPM. c) tort 0/17/25GPM ., 100 Pressure gauge .. 101 Vacuum gauge 102 Compound gauge 103. Flow gauge Flaw indicator sight glass • Sped& aint Colon ........ ...... s r_._.�.-...._._..._. Epoxy'' men............_... _..........._........ ........ 190 Weae:erroolmodificaUcn CONTROL DEVICES 1 ALARMS Sirs 260 DI sconn ec switch 298 Ccntrone lay 334 Alermhom LEVELCONTROLLERS,GAUGES,MLLCONTRCLLERS 2010 . SST Level Controller _ 2015 Tank lee* sensor and alarm for SST ..:..... ___._.__ _ 2000 TC-774 Tank Monitor 2040 TC•775.Level Controller...._______.__..-- _, 2045 Laak sensor for TC _._._._�__..._. ..._.._._ DUPLEX PUMP SYSTEMS. STD 345 Duplex pump controller_... L4e li/�SJ Qrd TAC 261 System cirarlt breaker a) Singl a -phase b)3-phssa 262 Control pcwvtranafomtar___...... ._..... .... 271 Poweravailablegreen pilot flght _..• Set Jr' �r 5u� 281 Operation mode sel r__._T f.' __�.._....-A--194rol nA 285 Lose of ,flew alarm . L 3 _9..W.Ne. 9S.7:2.vprE <:_. PUMPS MOTORS 400 410 416 417 420 422 424 42d 420 430 432 510 511 600 605 016 615 622 tidO _ 635 _ 645 700 705 715 716 721 722 730 735 745 '67 7711 7a3 800 806 600 _ 905 7GPM pump .. le GPM pump 17 GPM ptxnp .. 25 GPM ptrrgs 3 GPM, pump ..' 5 1 GGP.M pump ..,f}57.,.%....:.«.._ 13 GPM, pump 23 GPM: pump ._ 45GPM, pump '._ .. 81 GPM. pump Tramhamer, for 1/3 HP motor....,._..._. ,'..._ Trartsiormer,.ler, lid HP 1/3 HP,115.1.60 molar _........,..... 1/3 HP, 230.1.80 rratof 1/3 HP,110.1-50 motor. ...... 1/3 HP, 220-1-50 motor.— _---. -- 1 /3 HP, 230/4803.80, OOP; motor - ..._... 1C3 HP, 2:A/4E0-1H30,TEFC motor whiarter 1/3 PP, 12VDC motor 1/3 HP, 24-28VDC motor_...._ ................_:..._;_._ la HP, 115-1.50,TEPCmotor .... :............:. 1/2 HP, 115-1.60 motor 1/2 HP, 230-1-80 rtotor. 1/2HP,110-1-6omotor_.. _._...___ '.. 12 HP, 2241-50 molar 12 HP, 230/4bGs-60 OOP motor wistarar 1 r3 HP, 222/480', -60 TEFC motor w/4'44er 1./2 HP,12VDC motor_........_...-_.._._.-... ' ., 1/2 HP, 24VDC motor . - 1/2HP, 115-1.80TEFLmotor Overload prone-ori motor Single phase magnetcmotor carter . 3-phase motor a'rafer. 8/4HP,11e-1- 0 motor 3/4HP, 230f480-3-80 motor w/ctu:er ....... 1 HP, 11$4-to motor 1HP, 230.1-60motor . 1 HP, 23ef4as3-80 motor wistaria( 1000 1 12H P,115-1 {-0, motor w/starter 1005 112HP,230.1-50Meter wfatateri . 1025 11p23, 2330/4o0.3-80 motarw/startar .._ .... 1100 2HP, 115-1-60rno:or ........... ....�._.. 1105 2HP. 230-1-eO Motor 11Z5 21-IP,230/480-S-60 motor SPECIAL OPTIONS 346 347 290 Two nrnnvsg time metes Manual,duplexpump selector switch .__ ----- Fuel rise pump -out control .-.-__Y.__............_ Your Simplex Representative tilikio .1411 hit ohs M PLC 113) N. MacArthur Blvd, Springfield, tL 52702' 50,4 c217526• 6, Fax (217) 5257884 Contact of r niatf• Quotation: Fuel Supply Systems _ciirezzt boa: TO: ATTENTION: PH. FAX MODEL SP5 -50- CD-Sk3 l PACKAGED PUMP SET, as ioilows: ITEM: Date Quotation # FS Elfecdve 60 days Customer Ref. Po Pos»; 0( FMi ❑Original Quote ❑Con rming wl e QQuoted as Below liQuoted to Spec. /Sy63-51 4, /41•4 it 0n IT Delivery: Drawings 3"'1 --weeks after receipt of order p&w sake&, Iz'. Equipment R weeks attei chirp. approval Ely acceptance dquote buyer wart that Sinaloa, Mal team andardiah Swims ra Subject to Simplex Standard Conettons of Saks and Waf y,e'44f6+A, 4A2866A Attached Terms: Net 30Days eV1.s%per month ser* adamsaferSOdays.torwen, account customers only. • F05 point SptnOM1eld, Muds (QWtOmerPne all frslght etsarges) '.. 5 kffID PQP5 ET Standard Equipment Note: All base prices include C.apdard 2GPM,'AMP, 115VAC pumps. Add optional pumps and motors to these bass prices as required. All SPS Pump Sets include centai melt sump with leak sensor. -BS (Basle Singte Pump) •Standard 2GPM,.'aHP, 115VAC pump -SS (super -Single Pump) • Standard 2e PM, 'BHP, 115VAC .pimp • Option 260, door mounted &scorned switch with Interlock • Option 787: w 768, single-phase starter with odd wired to terminal Macho • (2) Option 088,1' shutcfts on Mat and outlet • Opton 095, pressure read valve • Option 070, V check valve -BD (Baato-0uptax Pump) • DUPLEX Standard 2GPM,'SHP, 115VAC pump • Opton 345, eutornae° duplex pump controller • (2) Option 070, V. aheok valve . . SD (Super -Duplex Pump) • DUPLE( Standard 2GPM, 'aHP, 115VAC pulrp • Opton 345, autematlo duplex pump oentroller • (2) Option 070, 1' check valve • Option 260, door mounted disowned' switch v+rlh interlock • Option 763, single•phese starters' • (4) Optional' ahutcRa on inlet and outlet • (2) Option 025, pressure heltef valve near Speak:Flo= • Duplex Pumps) • DUPLEX laillgpsoriao.pwnp' • Option 345, automatic duplex pump controller • (2) Cption 070,1 • acidic riles • Option 260, door mounted dseetr oot at with Interact • (4) Opton 088,1, ahutoHa cc Wet and o4gt • (2) Opfkn 095, pressure regret valve' • (2) Option 1111.epeleplele gauge on each pump inlet,, with shut-off t o" • (2) Opdo l laralest gauge on each pump coat.. soh shuFottPlensat<t • (2) Option 285, toes of flow airmen pump adlvate ',4A80517.22502 Y A u c L ‘-sr- u Wv, c n. MECHANICALOPTIONS 010 Auxiliary hand pump ..._.-_.-r.-•-•-- 016 Auxflary hand pump 060 Fuel strainer ..... ._... :...... .... ... _._:._.-».-••____... 061" Fuel atrainer..:......... _..... ..a...____:....._._.._ 062 Duplex strainer a)1•NPT.. :_,-...._.... b) Ph' N PT..............«...._._..._..:._.»._1... c)2'NPT - ....... 070 Check valve/priming tea asaembty c) l'NP T d) 114' Ici 25GPM Solenoid valve a) h'NPT for 2 GPM _____-_-___.------- c) '«' NPT far7/10117GPM d) 1NPT_...._.._......:_......._.,__.__.� a) 114' N PT for 26GPM ..._....._._.....- -.-- O80 083 DCSciercld Valve a) W NPT b) NPT 087 Manual fuel cut-off valve a)15'NPT, bronze 5_7Q o66 b)14'NPT,bronze......._...._...--....--•--•_• c) 1h1NPT. fire rated •«...._...._.__.._.._._.,.. d) NPT, fire. rated.:.._......-__ Manual fuel art -of valve a) 1'N PT, bronze --•------- b) 2'NPT, bronze ............ ___.__._�_...:.»..........- c) 1'NP7. fire,rated.._............. d)2'NPT. fire rated ............ OS1 Fusible link valve a)1'NF i ......�_._.-._.. b) 2-NPT _ . «.-.. 095 Pressure relief valve ••••� e) for 2 GPM ....... .... :_.__.,_.—•---- Is) fcr7GFM -... c) `cr 10/17/25GPM 100 Pressure gauge a ». ._ _.:_..._ 101 V5cuumgaugef ........_.__.--.:.___»,.... 102 Compound gauge . .. 1C3 F.owgaute 104 Flow indicator sight glass ....... ..... 140 Spedat paint colas :..._....�._..__...__...:..._ 141 Epoxy primer _ 180 Weal^.arrrcofnwdtficallon -_,. _ ....._.. CONTROL DEVICES& ALARMS .TD 260 Disconnect ewttch .......... _._�,..._._.»...,«._ 261 System carcuit breaker b) 3-phase 262. Ccnircl p:war transformer._.._.._...-:__.., 271 Power available green plot light 231 Operadcn mode selle�te�tc�r __••TT-•• 01 y..... 52 285 Loss of new alarraW._ r/ZG> 1 /L(rrP LZ4TL�A7S 23aCcnfrerrelay.....___........._.._._�._.___.-.__. 334 Alarm hcm _.... .� LEVEL CONTROLLERS, GAUGES, FILL CONTROLLERS 2010 SST Laval Controller._._.—....__....J_:_.«.._...•..... 2015 Tank leak sensor and alarm for SST -.--- 2030 TC•774 Tank Monitor ... 2040 7G775 Level Controller ___.._._.:.__....__._. 2045 Leak sensor for TC ...__._____._ -_-•. _ DUPLEX PUMP SYSTEMS S772 345 Duplex purnpcontrc ler, 4Z. /4 ere„Jvr 285 Flowseneor...._....__......_----_—_�_._�.—. 346 Two naming time mer= __—__-_-.- 347 Manual duplex pump selector SWittL,._._.:....-•--- 3S0 Fuel rise pump -out mood. . PUMPS & MOTORS a39 2 GPM pump . . 400 7GPM purrr 420 3 GPM, Dump 423 13 GPM, pump—...�..x.. _ 423 28GPM ;pumpC/f-ir.L%74N 19,R'7,. )a°DVe-Al 430 45 GPM. pump .. •»,• re."' RILL 4`..2 61GPM, ptrrP.» peNPS 510 Transformer. for 1/3 HP motor .:.._'......... ........._.:. 511 Traredonmer, for 1/2 HP BDO 149 FiP, A 157.80 mots __.__.__r 605 1/3 HP. 230-1.00 motor 615 1/3HP, 110-1-50motor, 615 12 HP, 2213-1-SO maw 621 1/3 HP, 23W488$00, OOP, molor. 622 1 /3 HP,;23OM60-1 -eO. TEFC maar whnr ._..:_ 630 12HP, i12VGCmotor ..._. -•- 035 1/3 H.P,,24.23VDC motor. 00 3 HP.115-1-60, TUC motor 7'00 1/HP:, 71,115-1-e0rnoNr._:... :._. _......_. 705 1 2 HP,:2304-SO motor ..._ .« __ - 71 i 12 HP,: 110-1-80 motor ....-..:-__....».._. 716 12 220-1•60 motor ___ 721 12 HP, 230/480-9-00 COP motor;w/starter 7= 1/9 HP 213/4803-63 TEFC motor w/;toner 730 12 h?:12VOC metal -...____--__.____:' 736 1/2 HP, 24VDC motor -- ..... 744 1/2HP 115-140 TEFC motor 767 evercad pretecdon motor - 765 Singh phase rnagne0c motor starter 770 3-prase rector starter _____ 800 • 9/4HP;115-1.5O motor 806 3/4HP, =0-1-60 motor _ fas 3/4HP 2901460-3-eQmotorw/darter __._• 800 1 HP,11S1.130 meta ..... -..» 905 1 HP, 2 1-60 rector 825 1 HP, 230/4&13-80 mctor wls1anWr 1000 1 1/2HP, 115-1-60 rndnrw/sbetat .. •• 1005 1 12rP. 230.1.6O motorw/starer 10^d 1112H P 23CV460380 motor W/atflrter ...«...».._... 1100 21'i°, 115.1-83 motor _....:___....:.._..»... ....._. 1105 2*IP, a.1-80 motor _-•---' .........." 1125 2HP,23C1480-1-60 motor SPECIAL OPTIONS 3 Fop cog, aOS 0 3y 1.2o0,2rn tA17,-ier5 Ott p if r9 rt ,.Ar r� p a As 4ded._°LJli 'J' • Your Simplex Representative Foot Valve Extractor EBW's 320 foot valve extractor is Designed for use with any 1 1/2" foot valve with a maximum outside diameter of 2 3/4", It is gasket -sealed to prevent loss of prime caused by air being sucked in through the top fitting.' Features Body constructed of Cadmium plated cast iron Bronze Cap & Suction Stub Adaptor The Gasket is gasoline & oil resistant leather 320 Extractor Assembly will take up to a 1 1/2" pipe and foot valve, or smaller size pipes and foot valves can be bushed onto assembly. 781 12" MANHOLE Part no. Description 320-302.01 1.1/2" outlet version, 320-302-02 2" outlet version 320-102-01 ,Cap Assembly 320.103-01 Insert Assembly' Dimensions 1-1/2" size 2" size Inlet Female thread Outlet thread Max. clear ID through valve Top thread Inlet Male thread 800 TANK VENT 1-1/2" 1.1/2' 1-1/2" 2" 2-7/8". 2-7/8" L Le. 760' 4" PIPE CAP - 320 EXTRACTOR- -782 DROP' TUBE -151 FOOT VALVE Sales Desk. (800) 475-3291 • Sales Fax (800) 475-4329 • Phone (616) 755-1671 2814 McCracken Avenue, Muskegon, MI 49441 C EBW Inc. Form No. 1064 11/94 aPrinted on recycled paper 4" 2814', McCracken Ave • Muskegon, MI • 49441 Order Desk (800) 475-3291 • Sales Fax (800) 475-4329 • Phone (616) 755-1671 All Brass Foot Valves All Brass Foot Valves are precision made to insure the highest degree of accuracy in con- struction and performance. Seats and discs are carefully machined and minutely inspected. Each valve is individually tested under pressure. The 24 mesh brass screen is firmly attached but can be removed. Single Poppet Foot Valves are of similar construction. Foot ValveDimensions Size Outside Diameter of Valve Length Single Poppet Length Double i Poppet 1/2" 1-7/16" 2-3/4" 4" 3/4" 1-11/16" 2-3/4" 4" 1" 2" 3" 4-1/4" 1-1/2" '2-3/4" 4-1/4" '5-3/8" 2" 3-7/16" 4-7/8" s-3/4" Single Poppet Part No. Size Weight 50 1/2" 12 oz.' 75 3/4" 15 oz. I 100 1" 1 lb. 2oz' 150 1-1/2" 3 Ib. 2 oz. 200 2" 4 Ib. 6 oz. Double Poppet Part No. I Size Weight 51 I 1/2" 1lb. 3oz. 76 3/4" 1 1 Ib. 5 oz. 101 1" 1 lb. 9 oz. 151 1-1/2" 4 Ib. 6 oz. 201 2" 6 Ib. 7 oz. Farm 1157 Aboveground Spill Container EBW's New 71/2 Gallon Spill Container EBw's new aboveground spill container gives overflow protection to aboveground storage tanks. Its 71/2 gallon capacity prevents potential environmental problems by containing fuel overfill spills during fill up. The new aboveground spill container has a built in drain which allows spilled fuel to drain back into the tank. The 14 gauge steel skirt and hinged locking lid, are epoxy -coated for corrosion protection. The base is cast iron and welded to the steel 'skirt. Features Built in drain 7 1/2 gallon capacity Epoxy coated for corrosion resistance Cast iron base 14 gauge steel skirt & lid Part No. Model Lbs. 706-42Q-01 Standard 40.0 706-420-65 Canadian'. 40.0 'Includes Riser Pipe; Cap & daptor I Anti -Siphon Valve This valve automatically shuts off product flow when lines are broken, preventing fuel spillage and fire hazards. Each valve has an adjusting mechanism allowing for various. hydrostatic head pressure settings with the valve range. Both 1.5 and 2-inchvalves are available in Iwo head pressure ranges. The adjusting mechanism is lockable after the'; preferred setting is made.' The Anti -Siphon Valve also includes a pressure relief valve] eliminating thermal expansion of fluid in the lines. Recommendedtorall aboveground storage applications. Sturdy ductile iron construction. Head pressure Features Part No. Size (In.) ranges (tt.) Lbs. 616-300-01 1.50 5 to 12 4.60' 616-300-02 1.50 12 to 25 4.60 636-300-01 2.00 5 to 12 720 636-300-02 2.00 ',12 to 25 7.20 Ductile iron construction Hydrostatic pressure adjusting mechanism with weather cap Thermal expansion pressure relief valve Meet NFPA 30 and API/RP 2000 requirements Locking Fill Cap The Locking Fill Cap is a cost effective way to give your aboveground storage tank the added security it needs. This watertight, locking fill cap consists of a sturdy brass body with an attractive gray, epoxied, cast iron cap. Hole are uniformly located around the edge of the cap so that ihmay be locked in any position. Furnished with a Buqa-N gasket Features Part No. Size (in.) Lbs. Brass body and epoxied no-i of-oi 2.00 I 2..62 cast iron cap 770-101-02 3.00 4':'00 770-101-03 4.00 775 Buna-N gasket