Loading...
HomeMy WebLinkAboutF2005-0053 - Miscrf Corrections: Newport Beach Fire Department Fire Prevention Division 3300 Newport Blvd. Newport Beach, CA 92663 (949) 644-3106 Plan Check Correction Sheet PLAN CHECK NO.: 0282-2005 e _� &Atd ONINNv g CONTRACTOR: Metro Fire Protection sNlaaai 3a9 - -- S30IAU3$'IY�3N39 _.SAOM 011904 387NOIS 1N31111Vd3dPRO PROJECT: James Iryine Suig center—IN3W3J031MONNOY S.1NYOfIddV I� 1h;:dN JO A1103H1 JO S3'0-1d ONVSNYId'S30NVNIO80 PROJECT LOCATION: 1 Hoag Drive 1 dI NourpilniN0:, H 1.3V ao ONIa00 3am39 JHl l31134021dr, a0Jill .1001,LS ON101108 3H13SIA321 0 3N103' _! HOW 3H1 S3421lb 1 l^I aodM3N 30 A110341 DATE: 4/26/0 r ld nH NOd09NINOZONY3 A113H1M33N711d103 NI =,` rT1d 3S3,11 17H1 :3,t.'42,f I0N S100 1VAOHddV `N12 3 0 ) r ,r111J NfNIfH03H1.H11M N "it Nlms,a b us^IDa 1011VZIHOH10Y I:•da= 3i I'LII r:No;1 ION '31 _ .,:f11d 3S1H1 JO 1VAoaddy r<dYlla7d3n r.N:11'N" HOY 312r7JM3N 30 AJJO IIDesigner to stamp and sign drawings. 4.g rr'r Ilxj uCTukE rs atrT'ibuSs�S a2 Lj1 tJ oo D �azS`r Show detail from truss manufacturer showing how main is hung from joist meets their requirement. NM SCE4u5L Ett FOIL _� dsfrptOn_014 *a.. l t Seismic bracing form filled out incorrectly, see sheets. SrF ,tCv'ZSED e4cC5 W rfltrs“ NyDfcsc.rc QALCS ✓5. Provide "k" factor of sprinkler heads on plan. SSE REVrsED &Saiq_ ItorEs a t s-Pftr&k[steu-pircr_rrar 16. Plans state 1" pipe is schedule 40, calculations show a Larger inside eo diameter, clarify. SCE tct)rScb idyl kouC CALLS Plans state 21/2" pipe is schedule 10, calculations show a larger inside diameter, clarify. S Eel- Pe F S-/ Gas:NJ G-04 t,L ntrrE S Fala_ Cer_-CT7-xcw.1S FAX NO. : Maid. •05 2005 10:24AM P1 Comments; Newport Beach Fire Department Fire Prevention Division 3300 Newport Blvd. Newport Beach, CA 92663 To: Company: Phone: Fax: From: Company: Phone: Fax: Date: # of Pages: including cover Facsimile Cover Sheet Emmanuel (818) 710-6055 Lillian Washington Fire Prevention Division (949) 644-3106 (949)644-3120 May 5, 2005 2 High Priority/Deliver Immediately X Normal Processing Addressee Phone After Review _ Pursuant to Your Request Confidential —Addressee Eyes — Only! Phone Verification — Receipt For Your Information Original to Follow via U.S. Mail CITY OF NEWPORT BEACH BUILDING DEPARTMENT 3300 NEWPORT BLVD. P.O.BOX 1768, NEWPORT BEACH, CA (949) 644-3275 C44/944y-3ZS'5 Project Address: I /4-t&o o Plan Check No.: o a va - aoos Date: 41.24/0 s- yy'�� NEWPORT BEACH BUILDING DEPARTMENT{� Plan Check Engineer. ArPrl Strof`,Stq ."c DOER N • G^rls= nIYEp'EMcsG ^R ,tn' Gtjc • 3a$3— ALITH r,= O - ' FRY BUILDIN 'SLAT r N OF OF INCONSISTENT WI II F• OBIT °.,E; r1D POLICIES Cr III-1YO' N ;FORT BIRCH.'rijtS AEPE•h:'L r-0-S FFFWEE THAT THESE PANS ARE- IN ALL RESPECTS. IN NON-RESIfl 4.f i .SI i anaPa"PIONS REiISr III al ^l: STRH T(1 R OVE ENI AUTHORIZED BY I HESE PLANE EL.:D'JC'I( U.; -ITER CONSTRUCTION IF NECESSARY TO COMPLY WITH THE Codes and Standards Used: Dl,mr...ttitjri'i "NEW lifflta°f lle ks Design Criteria, APPLCF;:Nl ERW1 Edition I CFP ,STIl.'I' SIGNATURE RATE Designer � W\ z4.4 L ;,., Phpne• 3)--49 2 `'JA3 G Designer to have LicenselClassific_arion marked below • IKl C-16, AP -dass1 ] "A` (Gen. Engineering) (underground & oveilicad) Undc.Ey..,und OPE& (Note: Contractor may only design sprinkler systems, which he will install). Fire Protection Engineer and Civil Engineer may design both underground and overhead portions. Specify: [ ] job address, [ j owner's name & address, 001C)I ppsigov�ners namle anii license number. ,t�'cryVLpL en Designer to stamp and sign the drawi gs. C-V--- Architect to coordinate deferred sprinkler drawings submittal with architectural drawings and certify sprinkler drawings prior to submittal to plan check. Specify type of sprinkler system. 14.3. [ ] Wet pipe [ ] Dry pipe [ ] Pre -action [ ] Circulating closed loop [ ] Deluge [ J Anti -freeze [ ] Combined dry pipe and pre -action [ ] Combined Standpipe/Sprinkler System [ ] Gridded [ ] Looped 1 K Specify type of joints and fittings for UG. pipe. All joints and fittings to be approved, compatible with pipe used. a. Underground ferrous metal pipe to be lined, coated, wrapped and sleeved with 8 MiL polyethylene sleeve (local requirement 7-2). b. Connection bolts to be stainless steel (local requirement 8.5.3). Private fire service main to be 6" min. 7-6.1. Show location of sectional value(s) for private fire service main water supply. 3-5.1. UG. pipe to a minimum of 30" below grade (36" below grade in paved areas). 8-1.1. UG. pipe not to pass under building. 8-3.1. Specify method of U.G. pipe restraint. Provide details. 8-6.2. Specify that underground pipe to be flushed per 9-1.1. Provide hydrostatic test notes. UG pipe to be tested per section 9-2. Show location of fire hydrants on site plan 2. St FS—I 5Z"7i N.A,J Provide a riser detail (elevation). Specify clearance around riser and all pipe penetrating rigid walls and floors. 1" for pipes < 3 1/2"@ and 2" for pipes > 4" @, provide caulking for mains and cross main. 6-4.4.1 Provide a system drain. Size per table 5-14.2.4.2. Provide a test drain valve. Show what each system test drain line empties to in order to prevent water damage. System has more than 20 heads, provide a flow switch and local water flow alarm. 5- 15.1.1 Water flow alarm to be monitored in high-rise buildings (5-15.1.6) or if the system has more than 100 sprinkler heads (more than 20 heads in I Div. 1 occupancy) (CFC 1003.3.1). Provide alarm drawings. Provide a pressure gage on riser near the system main drain (5-15.3.1). Specify type of OH. pipe to be used in accordance with Table 3-3.1. 3 • fi /5-2 7< Lateral bracing shall be spaced for main and cross main at a maximum of 40 feet. 6-4.5.3 Exception #2 for 6 inch rods Exception #3 for U-hooks Provide specs and drawing for sway bracing or specify the NFPA standard bracing from tables 6-4.5.8; 6-4.5.9. a. Specify sprinkler head and listing. Orifice size to be 1/2" nominal. b. Dry preaction system requires upright sprinkler heads or pendant heads listed for dry use. c. Specify quick response sprinkler heads for new light hazard occupancies. Provide spare sprinklers per 3-2.9.3. SystemSpare Sprinklers 0-300 6 300 —1000 12 Sprinklers to be spaced per Table 5-6.2.2(a), (b), (c) Minimum distance between sprinklers to be 6 feet, 5-6.3.4. Sprinklers in concealed attic space shall be of intermediate temperature classification. 5- 3.1.4.2(6) Sprinkler head to be at ft. from wall and not more than 9' from wall in small rooms (800 ft2). 5-6.3.2.1 Min. distance to wall 4". 5-6.3.3 Sprinklers adjoining ceiling mounted obstructions must comply with Tables 5-6.4.1.2 and 5-6.5.2.3 for floor mounted obstructions. Sprinkler deflector to be 1" to 12" below smooth ceiling. (1" to 6" below structural members. 22" max. below deck for obstructed condition.) 5-6.4.1.1 and 5-6.4.1.2 Sprinkler deflector to be parallel to sloped ceiling. 5-6.4.2 Minimum clearance below sprinkler is 18". 5-5.6 Sprinklers to be provided in kitchen exhaust duct serving the hood at: a. duct entrance b. at top of each vertical nser c. at the midpoint of each offset d. at 10 ft. on center in horizontal ducts e. hood exhaust plenum chambers shall have a sprinkler at 10' on center maximum spacing (4-9.3; 4-9.4; 4-9.5) 5 NEWPORT BEACH FIRE DEPARTMENT STANDARD FIRE PREVENTION SPECIFICATIONS STANDARD #F-1 Description: Signs on Fire Department Connections. Authority Fire Code Section: NFPA 13, NIPA 14 C.A.C. Title 19 U.F.C.10.105.(b) General Proper identification of Fire Department Connections (F.D.C's) is essential for successful tire fighting operations in buildings with built-in fire protection. In order to simplify department operations, it is important for signs on F.D.C's to clearly indicate the location of the system being served, the type of system and the proper pump pressure needed if necessary. Requirements for Identification Signs at Fire Department Connections. A. Signs shall be constructed of a durable material, preferably metal. B. Signs shall be a minimum of four inches high by eight inches wide. C. Lettering on the sign shall be at least one inch in height on a clearly contrasting background. D. Signs are to be permanently mounted on the building adjacent to, or directly on the F.D.C. and must be visible from the adjacent roadway. E. In addition to other requirements in this specification, all signs must state the address of the building being served. 7 For systems in which the riser serves both the standpipe and sprinkler systems and supply is provided by an on -site fire pump calculated to supply both the sprinkler and standpipe demand. (Consult with Fire Prevention for assistance.) Sprinkler System & Standpipes Pump $ PSI 4675 MacArthur Court * To determine the pump pressure stated on the sign; 1) Determine the operational pressure of the on -site fire pump, 2) Adjust for the difference in elevation between the F.D.C. and the fire pump at.434 psi/ft., 3) Add 25 psi for system friction loss. Example: 1. Pressure stated on the test plate on the on -site pump = 180 psi. 2. If the pump is below the F.D.C., subtract .434 pounds per foot of difference. 180. 10' x .434 = 4.34 psi - 4.5 3. Add 25 psi for friction loss in the F.D.C. + 25. Total amount to be stated on sign: 200 psi IV. Identification signs for standpipe systems. A. For F.D.C's which serve risers in all stairways: Dry Standpipe All Stairways 4910 Birch 1 B. For F.D.C's which serve individual risers or risers in a single stairway: Dry Standpipe North Stairway 3000 Park Newport 1 9 n METRO FIRE PROTECTION HYDRAULIC CALCULATIONS FOR JAMES IRVINE MEDICAL CENTER #1HOAG DRIVE i 300 BLOCK OF HOSPITIAL ROAD NEWPORT BEACH , CA. DATE:4-15-2005 DELTA 1 REV. 5-12-05 Occupancy Classification: Density: Area of Application: Coverage per Sprinkler : Total Sprinkler Demand: Flow and pressure at base of riser: Sprinkler orifice size Authority Having Jurisdiction: Design By: - - - DESIGN DATA - - - Oil Y nE'IEC:."RT BEACH BUIL DING DEPARTMENT APPR0mAE OP 1.! {U;P ? -✓aRil.� AZiIDXE➢REaTr1R�iI ILD IT' F C Pr r C ! E: E F!' H AS PMR9:L p,�E` :I IE i�. I;:S CO PI - A5 4TuC�vN";. 1 7 1 � h S M1i ror 0'<'rt TIT 1' OF ` .Es PEUSE JFE �R IAA i F F v BE :E 01 ..,ENT a'. b��}F1�N✓1q��*''�q {4 �7y H, bi THE °TONTMCE .SAE r..T ES2 I HE CID' Gr NE:1E0RI BEACH�Y� r7HE APPI ICAN S .'CNII0IL'I 113'9Q.ET_ D.' ELSiyNAIURE PUG"' HFS _'JATE GI, FMIr,' 3�3AGPM. (SIGNATU4EI DE a; :c_ = 223.4-gpm @ 15.1 psi BY. 1/2 PPPROVA: .ES,iE CATS NEWPORT BEACH FIRE DEPT. Metro Fire Protection Ignacio Reyes Flow Test Information: BY: CITY OF NEWPORT BEACH WATER DEPARTMENT Static = 72.0 PSI Residual = 62.0 PSI Flow = 1186 GPM 4- 7-051 2:34PM:CTY OF N.6 UTILitiES ;9496465204 1/ 2 FAX TRANSMITTAL DATE:. April 7, 2005 70: Chuck Metro Fire Protection Fax # (818) 710-6055 FROM: . Loren Love City of Newport Beach SUBJECT: Fire Hydrant Flow Test for the James hvine`Surgery Center Chuck- Here is the flow test for the above address. Feel free to call me at (949) 718-3410 ifI can be of any further assistance: Sincerely, Loren K_Love Pages to follow: 1 2890 AMOUNT PAID: $188.00 CHECK NO: 10833 TEST NO: N/A PROJECT: PROJECT LOCATION: TEST CONDUCTED FOR: TEST PERFORMED BY: TEST WITNESSED BY: STATIC HYDRANT 0: F/HMANUFACTURER: STATIC PRESSURE. (Ps , ps) RESIDUAL PRESSURE, (Pr ; psi) FLOWING: 62 FLOW HYDRANT 9 : F/HMANUFACTURIR: "--`314 LOCATION 308110SPITALROAD NUMBSTATIC PRESSURE, PRE FLOW po ER ec S� OF OUTLETS: I _ 4•: 2 - 25• FIROUTLET SRE (2.5 ar4.0Xbathes (II4FO ONLY, NOT FOR TEST CALC3) ; FLOW LOSS COEmC!!•IJT - TUBE C 1.0 / BUTT C-0.9 2.3 01, ) PITOTTGAUGE READING (p. psi k CITY OF NEWPORT BEACH UTILITIES DEPARTMENT FIRE HYDRANT FLOW TEST DATE: 04/17/2005 TIME: Z15 P.M WEATHER: CLEAR JAMES IRVINE SURGERY CENTER #1 HOAG DRIVE/ 300 BLOCK OF HOSPITAL ROAD METRO FIRE PROTECTION JJOE HOWL$ GIL GOMEZ FIELD OBSERVATIONS AND FLOW DATA 828 LOCATION: 351 HOSPITAL ROAD NUMBER & SIZE OF OUTLETS: 11-4', 2 -2.5' JONES JONLS OBSBRVEp ficAiz T 2 OBSERVED Fun/ FROMAHYPBANI'OU7ilrn CAXflfl1PD PROM THE FOLLOWING EQUATION: Q,=29:83(Cd'� COHERE; Q IS THE IN PSI AND C /SC ED F LOW IN � d ISTHE OUTLET DIAMETER IN THEp IS THE PPt)TGAUGE FLOW LOSS COEFFICIENp(C = LA FOR FLAW TUBES AND C = 0.9 FOR BUTT FLAW READINGS).PRES OBSERVED FLOW (Qs, wm): 1186 GPM DISCHARGE CAI.GS: THE DISCHARGE FOR GIVEN FIRE HYDRANT CAN BE DETEENNED FROM THE FOLLOWING WEQUATION USING THS INITIAL( STATIC) WATER PRESSURE AND THE RESRWAL (irf'NAMIC) /P �P, = P,/ Qr=Qs WHERE Q (STATIC OR RESIDUAL) 1S THE FLAW IN GPM AND P (STATIC OR RESIDUAL) I3 TH/3 PRESSURE IN PSL NOTE: A 10 P37 DROP IS REQUIRED FOR VALIDTF575 CALCULATED FLOW AT 20 p u (Qr, ppm): GPM `IMPORTANT NOTE* THE MAXIMUM STATIC DESIGN PRESSURE FOR A FRE SPRWRIER SYSTEM SHALL BE SO PSL 13-220 INSTALLATION OF SPRINKLER SYSTEMS Figure A-6.4.5(a) Seismic bracing calculation form. Seismic Bracing Calculations Sheet of Project Address: sarsnawg sa y O7JC NOACG Dt. fleearctcr We j j, CA 922655 Contractor. Address: Telephone' Fax: h ' r-t ill i rrozf 7sao beartjdr AVE. 0.fichte&A Pik AA 91202. (RIP)710-605Q (Bit 71 O- o5S Brace Information Seismic Brace Attachments Length of brace: Diameter of brace: Type of brace: Angle of brace: Least radius`Ol gyration:' UR value:* Maximum horizontal Toad: D" / rf Sag Lit 5q° La /00 4500 M5 Structure attachment fitting or tension-annlv bradna system: A Make: rotcc) Model: L 0 9 / t 1 listed bad rati g:A5/S Adjusted toad rating per 6-4 5 7: Sway brace (pipe attachment) fitting: Make: fltca Model: ab, C7 / A Listed load rating:a 76 5 Adjusted load rating per 5.4.5.7: Fastener Information Orientation of connecting surface: _ Fastener. Type: Diameter. Length (in wood): Maximum load: Telt.o rl,-M CSocr 7cd Or- I/,r 390 n Seismic Brace Assembly Detail Lateral Sway Brace tlmleam aXl1 or wood joist member Toko t' 909 Swivel Alfa nil 45 -.1Degrees Brace klenlit , .. (to be used or: .l Lateral brace - Sprinkler System Load Calculation Locate Nut Washer joist member tk T-0' Max. Srh. 40 Pipe TolesVat FestClamp Maui" 0 Longitudinal brace Diameter try Type Length (ft) Total (ft) % Weight per ft sC.i(. `ID 2-0 +I'--0"tl yL dr+i'-i] +2-flt• I-o t4- I-o';:t-OlfWo l+ 34r-0" Ib/ft ' 36 -o" Ib/ft -/,03 ibm ,2 93 Ib/ft lb/ft % Total Weight Ib Ib (47,7 lb /o6,2 Ib Ib Ib/ft Ib Total 'h weight of water -filled pipe • Excludes tension -only bracing systems cQrscD 5-tz-o5 166.9.7 Ib 1999 Edition 13-220 INSTALLATION OF SPRINKLER SYSTEMS Figure A-6-4.5(a) Seismic bracing calculation form. Seismic Bracing Calculations Sheet of Project Slit-W-C lvatE muittscry Address: Ot.IE Hod& De. Ne► iks r LScAe4cA 9,2650 Contractor. \lct Frtc Pfr-671rerreaAt Address: 7520 Deettr-Akr 4P&. CAAvnr,-A P,atcK, to 9►202, Telephone: L I S) Ito - 6t>So Fax: ($i) 7id-6056 Brace.information Seismic Brace Attachments Length of brace: Diameter of brace: Type of brace: Angle of brace: Least radiusal gyration:' UR value:* Maximum horizontal load: 5-0 ►v s _i4 t-1O 'IC- 594 .412 ►ov So0 t-gs Stntct re attachment fitting or tensbnoNy bracing system: Make: TOtCO Model 4I Litt Listed bad rating Adjusted bad rating per 64.5.7: _, Sway brace (pipe attachment) fitting: Make: Totter Mode: 907 Listed bad rating:276S Adjusted bad rating per 64.57. Fastener Information Orientation of connecting surface: Fastener. Type: Diameter. Length (in wood): Maximum load: 1741e,orAt ril 6O1.7 r2 A Brace (dentifk (to be used on Seismic Brace Assembly Detail Longitudinal Sway Brace 111x r Pax Sch. 40 Pipe. 15-.5/Degrees, Locate Nut &.Washer- thmleistmember T6ko1909 . -. Swivel Attachment Talc°. 4A ripe Clamp 0 Lateral brace 0 Longitudinal brace Sprinkler System Load Calculation Diameter " Type aYi' 5CH.tO Length (ft). 361-0 Total (ft) r v3ls—O 1A Weight per ft z, 9 5 tom lb/ft %Total Weight / 04, 2 lb lb lb/ft lb lb/ft lb lb/ft lb lb/ft lb Total % weight of water -filled pipe • Excludes tension -only bracing systems IEV-rssb 5-1z-o5 /06, 2. lb 1999 Eaton SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE': JOB TITLE: LIGHT HAZARD WATER SUPPLY.DATA C:\HASS71\JAMES IRVINE HOAG.SDF SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SOURCE 72.0 62.0 1186.0 71.1 323.4 45.4 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE TOTAL HOSE STREAM ALLOWANCE AT SOURCE OTHER HOSE STREAM ALLOWANCES TOTAL DISCHARGE FROM ACTIVE SPRINKLERS NODE ANALYSIS DATA 323.4 GPM 100.0 GPM 0.0 GPM 223.4 GPM NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) A 8.0 K= 5.60 17.0 23.1 Al 11.0 - - - - 16.9 B 8.0 K= 5.60 12.1 19.5 B1 11.0 - - - - 11.7 - - - C 8.0 K= 5.60 12.8 20.1 Cl 11.0 - - - - 12.4 - - - D 8.0 K= 5.60 18.1 23.8 D1 11.0 - - - - 18.1 - - - E 8.0 K= 5.60 16.5 22.8 El 11.0 - - - - 16.4 - - - F 8.0 K= 5.60 17.2 23.2 F1 11.0 - - - - 17.1 - - - G 8.0 K= 5.60 15.8 22.3 G1 11.0 - - - - 15.6 - - - I 8.0 K= 5.60 16.4 22.7 Il 11.0 - - - - 16.2 J 8.0 K= 5.60 17.3 23.3 J1 11.0 - - - - 17.3 K 8.0 K= 5.60 16.4 22.7 K1 11.0 - - - - 16.2 1 11.0 18.1 2 10.0 19.8 2A 10.0 19.8 3 11.0 19.4 4 10.0 19.8 5 11.0 18.3 6 10.0 19.9 7 11.0 18.4 8 10.0 20.0 9 11.0 18.5 10 10.0 20.1 11 11.0 - - - - 20.0 12 10.0 - - - - 20.4 - - - SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE': i -JOB TITLE: LIGHT HAZARD NODE ANALYSIS DATA (cont.) C:\HASS71\JAMES IRVINE HOAG.SDF NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 13 11.0 14 10.0 15 11.0 16 10.0 17 11.0 18 10.0 19 11.0 20 10.0 TOR 10.0 BOR 0.0 SOURCE 0.5 SOURCE 18.9 20.5 18.9 20.5 18.9 20.5 20.1 38.8 39.6 44.6 45.4 223.4 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: C:\HASS71\JAMES IRVINE HOAG.SDF JOB TITLE: LIGHT HAZARD PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -23.1 1.049 PL 3.00 PF 1.2 A 8.0 5.6 17.0 23.1 8.6 120 FTG 2E PE -1.3 Al 11.0 0.0 16.9 0.0 0.170 TL 7.00 PV 0.5 Pipe: 2 -23.1 1.049 PL 2.25 PF 1.2 Al 11.0 0.0 16.9 0.0 8.6 120 FTG T PE 0.0 1 11.0 0.0 18.1 0.0 0.170 TL 7.25 PV 0.5 Pipe: 3 -19.5 1.049 PL 3.00 PE 0.9 B 8.0 5.6 12.1 19.5 7.2 120 FTG 2E PE -1.3 B1 11.0 0.0 11.7 0.0 0.124 TL 7.00 PV 0.4 Pipe: 4 -19.5 1.049 PL 6.00 PF 0.7 B1 11.0 0.0 11.7 0.0 7.2 120 FTG ---- PE 0.0 Cl 11.0 0.0 12.4 0.0 0.124 TL 6.00 PV 0.4 Pipe: 5 -20.1 1.049 PL 3.00 PF 0.9 C 8.0 5.6 12.8 20.7. 7.4 120 FTG 2E PE -1.3 Cl 11.0 0.0 12.4 0.0 0.131 TL 7.00 PV 0.4 Pipe: 6 -39.6 1.049 PL 10.00 PF 6.9 Cl 11.0 0.0 12.4 0.0 14.7 120 FTG T PE 0.4 2A 10.0 0.0 19.8 0.0 0.459 TL 15.00 PV 1.5 Pipe: 7 -23.8 1.049 PL 3.00 PF 1.3 D 8.0 5.6 18.1 23.8 8.9 120 FTG 2E PE -1.3 D1 11.0 0.0 18.1 0.0 0.180 TL 7.00 PV 0.5 Pipe: 8 -23.8 1.049 PL 2.25 PF 1.3 D1 11.0 0.0 18.1 0.0 8.9 120 FTG T PE 0.4 4 10.0 0.0 19.8 0.0 0.180 TL 7.25 PV 0.5 Pipe: 9 -22.8 1.049 PL 3.00 PF 1.2 E 8.0 5.6 16.5 22.8 8.4 120 FTG 2E PE -1.3 El 11.0 0.0 16.4 0.0 0.165 TL 7.00 PV 0.5 Pipe: 10 -22.8 1.049 PL 11.50 PF 1.9 El 11.0 0.0 16.4 0.0 8.4 120 FTG ---- PE 0.0 5 11.0 0.0 18.3 0.0 0.165 TL 11.50 PV 0.5 Pipe: 11 -23.2 1.049 PL 3.00 PF 1.2 F 8.0 5.6 17.2 23.2 8.6 120 FTG 2E PE -1.3 F1 11.0 0.0 17.1 0.0 0.172 TL 7.00 PV 0.5 Pipe: 12 -23.2 1.049 PL 2.25 PF 1.2 F1 11.0 0.0 17.1 0.0 8.6 120 FTG T PE 0.0 7 11.0 0.0 18.4 0.0 0.172 TL 7.25 PV 0.5 Pipe: 13 -22.3 1.049 PL 3.00 PF 1.1 G 8.0 5.6 15.8 22.3 8.3 120 FTG 2E PE -1.3 G1 11.0 0.0 15.6 0.0 0.159 TL 7.00 PV 0.5 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: C:\HASS71\JAMES IRVINE HOAG.SDF JOB TITLE: LIGHT HAZARD PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 14 -22.3 1.049 PL 11.33 PF 2.9 G1 11.0 0.0 15.6 0.0 8.3 120 FTG ET PE 0.0 9 11.0 0.0 18.5 0.0 0.159 TL 18.33 PV 0.5 Pipe: 17 -22.7 1.049 PL 3.00 PF 1.1 I 8.0 5.6 16.4 22.7 8.4 120 FTG 2E PE -1.3 I1 11.0 0.0 16.2 0.0 0.164 TL 7.00 PV 0.5 Pipe: 18 -22.7 1.049 PL 11.66 PF 2.7 I1 11.0 0.0 16.2 0.0 8.4 120 FTG T PE 0.0 13 11.0 0.0 18.9 0.0 0.164 TL 16.66 PV 0.5 Pipe: 19 -23.3 1.049 PL 3.00 PF 1.2 J 8.0 5.6 17.3 23.3 8.7 120 FTG 2E PE -1.3 J1 11.0 0.0 17.3 0.0 0.173 TL 7.00 PV 0.5 Pipe: 20 -23.3 1.049 PL 4.25 PF 1.6 J1 11.0 0.0 17.3 0.0 8.7 120 FTG T PE 0.0 15 11.0 0.0 18.9 0.0 0.173 TL 9.25 PV 0.5 Pipe: 21 -22.7 1.049 PL 3.00 PF 1.1 K 8.0 5.6 16.4 22.7 8.4 120 FTG 2E PE -1.3 K1 11.0 0.0 16.2 0.0 0.164 TL 7.00 PV 0.5 Pipe: 22 -22.7 1.049 PL 11.50 PF 2.7 K1 11.0 0.0 16.2 0.0 8.4 120 FTG T PE 0.0 17 11.0 0.0 18.9 0.0 0.164 TL 16.50 PV 0.5 Pipe: 23 -23.1 1.049 PL 2.00 PF 1.2 1 11.0 0.0 18.1 0.0 8.6 120 FTG T PE 0.4 2 10.0 0.0 19.8 0.0 0.170 TL 7.00 PV 0.5 Pipe: 24 0.0 1.049 PL 2.00 PF 0.0 3 11.0 0.0 19.4 0.0 0.0 120 FTG T PE 0.4 4 10.0 0.0 19.8 0.0 0.000 TL 7.00 PV 0.0 Pipe: 25 -22.8 1.049 PL 2.00 PF 1.2 5 11.0 0.0 18.3 0.0 8.4 120 FTG T PE 0.4 6 10.0 0.0 19.9 0.0 0.165 TL 7.00 PV 0.5 Pipe: 26 -23.2 1.049 PL 2.00 PF 1.2 7 11.0 0.0 18.4 0.0 8.6 120 FTG T PE 0.4 8 10.0 0.0 20.0 0.0 0.172 TL 7.00 PV 0.5 Pipe: 27 -22.3 1.049 PL 2.00 PF 1.1 9 11.0 0.0 18.5 0.0 8.3 120 FTG T PE 0.4 10 10.0 0.0 20.1 0.0 0.159 TL 7.00 PV 0.5 Pipe: 28 0.0 1.049 PL 2.00 PF 0.0 11 11.0 0.0 20.0 0.0 0.0 120 FTG T PE 0.4 12 10.0 0.0 20.4 0.0 0.000 TL 7.00 PV 0.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: C:\HASS71\JAMES IRVINE HOAG.SDF JOB TITLE: LIGHT HAZARD PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 29 -22.7 1.049 PL 2.00 PF 1.1 13 11.0 0.0 18.9 0.0 8.4 120 FTG T PE 0.4 14 10.0 0.0 20.5 0.0 0.164 TL 7.00 PV 0.5 Pipe: 30 -23.3 1.049 PL 2.00 PF 1.2 15 11.0 0.0 18.9 0.0 8.7 120 FTG T PE 0.4 16 10.0 0.0 20.5 0.0 0.173 TL 7.00 PV 0.5 Pipe: 31 -22.7 1.049 PL 2.00 PF 1.1 17 11.0 0.0 18.9 0.0 8.4 120 FTG T PE 0.4 18 10.0 0.0 20.5 0.0 0.164 TL 7.00 PV 0.5 Pipe: 32 -23.1 2.703 PL 2.75 PF 0.0 2 10.0 0.0 19.8 0.0 1.3 120 FTG ---- PE 0.0 2A 10.0 0.0 19.8 0.0 0.002 TL 2.75 PV 0.0 Pipe: 33 -62.7 2.703 PL 5.50 PF 0.1 2A 10.0 0.0 19.8 0.0 3.5 120 FTG ---- PE 0.0 4 10.0 0.0 19.8 0.0 0.011 TL 5.50 PV 0.1 Pipe: 34 -86.5 2.703 PL 2.00 PF 0.0 4 10.0 0.0 19.8 0.0 4.8 120 FTG ---- PE 0.0 6 10.0 0.0 19.9 0.0 0.019 TL 2.00 PV 0.2 Pipe: 35 -109.3 2.703 PL 5.00 PF 0.1 6 10.0 0.0 19.9 0.0 6.1 120 FTG ---- PE 0.0 8 10.0 0.0 20.0 0.0 0.030 TL 5.00 PV 0.3 Pipe: 36 -132.5 2.703 PL 1.00 PF 0.0 8 10.0 0.0 20.0 0.0 7.4 120 FTG ---- PE 0.0 10 10.0 0.0 20.1 0.0 0.043 TL 1.00 PV 0.4 Pipe: 37 -154.8 2.703 PL 6.00 PF 0.3 10 10.0 0.0 20.1 0.0 8.7 120 FTG ---- PE 0.0 12 10.0 0.0 20.4 0.0 0.057 TL 6.00 PV 0.5 Pipe: 38 -154.8 2.703 PL 2.50 PF 0.1 12 10.0 0.0 20.4 0.0 8.7 120 FTG ---- PE -0.4 19 11.0 0.0 20.1 0.0 0.057 TL 2.50 PV 0.5 Pipe: 39 68.6 2.703 PL 1.00 PF 0.0 19 11.0 0.0 20.1 0.0 3.8 120 FTG ---- PE 0.4 14 10.0 0.0 20.5 0.0 0.013 TL 1.00 PV 0.1 Pipe: 40 46.0 2.703 PL 4.17 PF 0.0 14 10.0 0.0 20.5 0.0 2.6 120 FTG ---- PE 0.0 16 10.0 0.0 20.5 0.0 0.006 TL 4.17 PV 0.0 Pipe: 41 22.7 2.703 PL 4.00 PF 0.0 16 10.0 0.0 20.5 0.0 1.3 120 FTG ---- PE 0.0 18 10.0 0.0 20.5 0.0 0.002 TL 4.00 PV 0.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: C:\HASS71\JAMES IRVINE HOAG.SDF JOB TITLE: LIGHT HAZARD PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 42 -223.4 2.703 PL 41.25 PF 18.3 19 11.0 0.0 20.1 0.0 12.5 120 FTG 9E2T PE 0.4 20 10.0 0.0 38.8 0.0 0.113 TL 162.48 PV 1.0 Pipe: 43 -223.4 4.310 PL 8.00 PF 0.7 20 10.0 0.0 38.8 0.0 4.9 120 FTG 2ET PE 0.0 TOR 10.0 0.0 39.6 0.0 0.012 TL 63.75 PV 0.2 Pipe: 44 -223.4 4.310 PL 10.00 PF 0.7 TOR 10.0 0.0 39.6 0.0 4.9 120 FTG CB PE 4.3 BOR 0.0 0.0 44.6 0.0 0.012 TL 57.39 PV 0.2 Pipe: 45 -223.4 4.240 PL 50.00 PF 1.1 BOR 0.0 0.0 44.6 0.0 5.1 150 FTG 2ETG PE -0.2 SOURCE 0.5 SRCE 45.4 (N/A) 0.008 TL 131.00 PV 0.2 NOTES: (1) Calculations were performed by the HASS 7.1 computer program under license no. 4904076820 granted by HAS Systems, Inc. 4792 LaVista Road Tucker, GA 30084 (2) The system has been calculated to provide an average imbalance at each node of 0.004 gpm and a maximum imbalance at any node of 0.174 gpm. (3) Velocity pressures are printed for information only and are not used in balancing the system. Maximum water velocity is 14.7 ft/sec at pipe 6. (4) PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP PAGE: * MATERIAL: 840 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N E11 Tee LngEl1 ChkV1v BfyVly GatV1v AlmChk DPV1v NPTee 2.703 9.33 18.65 6.22 21.76 10.88 1.55 15.54 15.54 18.65 4.310 13.94 27.87 8.36 30.66 16.72 2.79 27.87 13.94 27.87 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: C:\HASS71\JAMES IRVINE HOAG.SDF JOB TITLE: LIGHT HAZARD PAGE: A MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVly BfyV1v GatVly AlmChk DPV1v NPTee 1.049 2.00 5.00 2.00 5.00 6.00 1.00 10.00 10.00 5.00 PAGE: E MATERIAL: PVC150 HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G N Ell Tee LngE11 ChkVly BfyVly GatVly NPTee 4.240 19.00 39.00 12.00 43.00 23.00 4.00 39.00 DATE: _ SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 8 C:\HASS71\JAMES IRVINE HOAG.SDF -JOB TITLE: LIGHT HAZARD WATER SUPPLY ANALYSIS 120 0 100.0 G A U G 80.0 E P 60.0 ( 40.0 p s i 20.0 0.0 Static: 72.00 psi Resid: 62.00 psi Flow: 1186.0 gpm -14.7 1 1 I l 1 1 1 LEGEND 1% Available pressure 71.10 psi @ 323.4 gpm 2fl Reauired pressure 45.43 psi @ 323.4 gpm 400600 800 1000 1200 1400 1600 1800 2000 FLOW (GPM) METRO FIRE PROTECTION, INC. 7520 Deering Avenue, Canoga Park, CA 91303-1406 Tel. 818/710-6050 Fax 818/710-6055 Lic. 578097 email: metrofireprotection@earthlink.net February 3, 2005 A. tow 127 Z°°C JAMES IRVINE SURGERY CENTER 301 NEWPORT BLVD. NEWPORT BEACH, CA FIRE SPRINKLER SYSTEM PRODUCE CATALOG ;; LOBE® A- FIRE SPRINKLER CORPORATION AUTOMATIC SPRINKLERS GL SERIES UPRIGHT • PENDENT DESCRIPTION AND OPERATION The Globe GL Series Sprinkler is a low profile yet durable design which utilizes a frangible glass ampule as the thermosensitive element. While the sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified. This sprinkler series is available in various styles, orifices, temperature ratings and finishes to meet varying design requirements. The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used. RTICA TECHNICAL DATA See reverse side for Approvals and Specifications. Temperature Ratings - I35°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (I4I°C), 360°F (182°C). o Water Working Pressure Rating - 175 psi (12 Bars). o Factory tested hydrostatically to 500 psi (34 Bars). o Maximum low temperature glass bulb rating is -67°F (-55°C). o Frame - bronze o Deflector - brass - Screw - brass Bulb seat - copper o Spring - niclel allay Seal - teflon Bulb - glass with glycerin solution, 5mm size. UPRIGHT CONVENTIONAL PENDENT VERT SIDEWAL HORIZONTAL SIDEW SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION ORDINARY INTERMEDIATE HIGH EXTRA HIGH AVAILABLE: SPRINKLER TEMPERATURES 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 BULB COLOR ORANGE/RED YELLOW/GREEN BLUE MAUVE N.F.P.A. MAXIMUM CEILING TEMPERATURE. 517-846-4583 • FAX 517-846-9231 NOVEMBER 2000 A-12 BULLETIN GL5661 AUTOMATIC SPRINKLERS GL SERIES UPRIGHT PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE *LENGTH FINISHES 2.8 (39 metric) 1/2" NPT 2 1/4" (5.7 cm) Factory Bronze "*Satin Chrome 4.2 (59 metric) 1/2" NPT 2 1/4" (5.7 cm) Bright Chrome White Polyester+ --> 5.6 (80 metric) 1/2" NPT 2 1/4" (5.7 cm) Black Polyester+ 7.8 (1 I 1 metric) 1/2" NPT 2 1/4" (5.7 cm) Wax Coated **Lead Coated 8.1 (116 metric) 3/4" NPT 2 7/16" (6.2 cm) ***Wax over Lead METRIC CONVERSIONS ARE APPROXIMATE. APPROVALS * HORIZONTAL SIDEWALL IS 19/16". °S FINISHES AVAILABLE ON SPECIAL ORDER. ***WAX COATING UL LISTED UP TO 200"F ONLY. *AVAILABLE AS UL AND C-UL LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDEP STYLE MODEL K FACTOR I35°F S7°C I55°F 68°C: I75°F 79°C 200°F 93°C 286°F I4I°C 360°F I82°C U'L CANADIAN U.L F.M' N.Y.C.D.OB, MEA 101-92-E GL2861 18 X X X X X X X X — X GL4261 4.2 X X X X X X X X — X UPRIGHT 3'GL5661 5.6 X X X X X X X X X X GL8I61 7.8* X X X X X X X X X X GL8164 8.1 X X X X X X X X X X GL2851 2.8 X X X X X X X X _- X GL4251 4.2 X X X X X X X X — X ). GLS6S I 5.6 X X X X X X X X X X PENDENT GL8151 7.8* X X X X X X X X X X GL8I56 61 X X X X X X X X X X yEjC{{ GL5675 5.6 X X X X X X X X -_ SIDEWALL ,B 8.1 X X X X X X X X -_ -_ GL2870 28 X X X X X X — X HORIZONTAL GL4270 4.2 X X X X X — X SIDEWALL § GL5670 5.6 X X X X X X X GL8171 8.1 X X X X X ) X — X CONVENTIO 5.6 X X X X X X — — — O GL8I69 8.1 X X X X X X — — _ --- ORDERING INFORMATION SPECIFY ° Quantity ° Model Number = Style ° Orifice o Thread Sizes Temperature " Finishes desired Quantity - Wrenches - P/N 325390 (I /2"); P/N 312366 (LO.) (ft LOBE �� �' FIRE SPRINKLER CORPORATION NOVEMBER 2000 'LECTOR 1" TO 12" BELOW THE CEILING, FM APPROVED 4" TO 6" } VERT1CA SIDEWALL UL LISTED FOR UGHT HAZARD ONLY PENDENT VERTICAL SIDEWALL UL USTED FOR 6' MIN. SPACING UPRIGHT VERTICAL SIDEWALL UL LISTED FOR 9' MIN. SPACING. * 12" NPT. GLOBE° PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufac- tured products found to be defective in material or workman- ship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 517-846-4583 FAX 517-846-9231 -800-248-0278 www.globesprinkler.com PRINTED U.S.A. BULLETIN GL5661 , •.. . ._. Threaded Fittings Ductile Iron - 800 Series ANSI 616.3 Manufactured by: Central Grooved Piping Products, Inc. a subsidiary of Central Sprinkler Company 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 111 Product Description Central Ductile Iron threaded fittings conform to ANSI B16.3 and are higher in strength and more corrosion resistant than cast iron fittings. The additional strength is provided by the ductile properties making up the fitting. This is accomplished by adding magnesium while the iron is being poured into its final cast shape. This provides an advantage as the fittings are not as susceptible to leaks or cracking and they are also lighter than standard cast iron. Caution: Installers who have not used ductile Iron threaded fittings before should be instructed that the fitting is stronger than the pipe and over -tightening the fitting can create leaks and cause damage to pipe threads. In general, there Is about one-half a turn difference between cast iron and ductile Iron fittings. Apply Teflon tape or high quality pipe joint compound on the pipe threads and tighten two to three turns beyond hand tight. If you are using an automatic make - on machine, please exercise caution In setting your machine to the proper parameters prior to tightening fittings onto the male pipe threads. Technical Data Model: 811, 812, 813, 814, 815, 816, 817, 818, 820, 825, 825B, 827, 830, 719 Style: Elbows, Tees, Unions, Caps, Extension Pieces, Bushings, Couplings and Plugs Wrench: Standard Pipe Wrench Thread: N.P.T. Material: Ductile Iron Maximum Working Pressure: 300 psi Weight: See Chart A Appro sh in Appr s: .L., U.L.C., F.M. Central Grooved su t for exact Listing/ ation.) b Ittal prove! • • IIP • • a it • • Installation Apply Teflon tape or high quality pipe joint compound on the pipe threads and tighten two to three turns beyond hand tight. 90° Elbow Model 811 90° Reducing Elbow Model 812 45° Elbow Model 813 1 Ductile Iron Tee Model 814 90° Elbow - Model 811 Wt. Box Size A B Part Y (Ibs.) Qty. 12 1'/s 9/,. 86206 .24 240 3/4 15/,, 3/4 86205 .40 120 1 1'/2 "/,a 86200 .64 70 11/4 13/4 11/2e 86201 .95 40 11/2 115/,, 1'/,, 86202 1.24 30 2 2'/4 1'/2 86203 1.74 20 21/2 2'1/2e 19/14 86204 3.28 10 90°Reducing Elbow - Model 812 Size 3/4x'h 1 x '/2 11/2x1 1'/2 x 114 2 x 3/4 2 x 1 2 x 1'/2 2'/2 x 2 13/4 13/44 Ph4 I'/,, 1'/2 15/, 113/,a 15/4 13/. 2 22/2 1 "he 1'/e 1' ha 21/ 4 23/u 25/. 45° Elbow - Model 813 86342 86210 Wt. Lbs. .33 .44 86211 i .53 86212 .64 86213 .75 86214 .77 86221 .95 86215 86216 86217 86218 86220 86262 Size '/2 3/4 A la 1 B 3/a 2/,e Part s 86780 86781 "/,, 86280 5h 86281 "/1° 86282 18hs 86283 1 86782 Wt. Box (lbs.) Qty. .22 250 .33 (150 .48 90 .73 50 .93 35 1.55 18 2.70 12 Tee - Model 814 Wt. Box Size A B Part It (Ibs.) Qty. '/2 1'/, 'he 86340 .33 150 3/4 11/2e 3/4 86341 .50 90 1 11/2 "he 86230 .85 60 1'/4 114 1 Yu 86231 1.30 35 1'/2 1'1/2" Pm 86232 1.63 24 2 21/4. 11/2 86233 2.63 12 21/2 211he 19h4 86234 4.55 8 Box Qty. 160 110 90 75 60 55 45 40 35 30 25 20 157 1 x 1 x'/3 1'/. 11/4 1%a °/s '/o "/u 86238 .66 65 1 x 1 X 3/4 1'/. 136 1 /,, "As 7h 86239 .73 60 1 x 1 x 114 "h, 1"/, 1°/,s 1 1 2G 86240 .97 45 1 x 1 x 11/2 "/,, Ph 1% Ps 11/. 7h 86241 1.14 35 114 X 1 x'4 15/,, 1'/. 1%4 5h s/,a 1 86242 .81 50 17/4 x 1 x 3/4 P/o 1'b 1% 3b "/', I'/. 86243 .90 50 11/4 x 1 x 1 1'/12 11/2 11 Vv 7/, "Al 1 86244 1.03 45 1'/4 X 1 x 1'/. 13/4 1"/, 13/. 1'6. 1 Pm 86245 1.10 40 11. x 1 x 11/2 11. 1136 119/,, 13/,. 11/2 1 Vu 28246 1.43 30 11/4 X 1'/. x 1/2 13h 13/, 113/, 11hs 86250 1.50 30 1'/. x 1'/. x 2 2'/. 21/2 2 1'/,. P/. 1'/, 86251 2.00 24 11/2 x 1 X'/2 P/o 15/,4 1"/, 11u 5b 1K 86252 .97 40 Ductile Iron Tee - Reducing - Model 815 Size A IBCD E 3/4 1/2 x '/4x 13/4 Wm1 V. 5/e 5/, 3/4X 3/.X 1 I1'/u 1 P14 1'h 1 7/e 'b 1 x'/2x 1 11/2 1 1'/e 1'/. 113/14 1 x 3/4x '/2 F 1'h. 11h. 13/e 13/1. 11h 13/,4 13/. °/1s ! 5/, 11b. Part 9 86235 Wt. Lbs. .46 Box Qty. 95 86755 1 .68 1 65 86236 1 .70 f 55 86756 .63 80 1 X 3/4x 3/4 11. 15/12 P/o 11h, 3/4 7/2 86757 .68 65 1 x 3/. x 1 1,/2 17/,, 11/2 13Ge - 76 "/14 86237 .77 55 1 86247 .87 45 1'/. X 1 V4 x 3/. 17/,. 17/s 15/s 3/4 3/4 11/22 86248 .96 45 11/. x 11/4 X 1 Os 19/4 1"/,e 7/2 7h 1 86249 1.10 40 I 11/2 x 1'/. X 1'/2 Ph Ph 1 "/14 1'/2 x 1 x 3/4 11h 13/sI 13/4! 3/4 11/h. 13h4 86253 1.14 40 1'h x 1 x 1 115h i 11/2 1t3/u4 7/, { 19h, PL 4 86254 11.14 130 11/2 x 1 x 1'/2 115/14 1'/. 11/2 Ph. 86255 1.52 30 11/2 X 11/4 x 1/2 110 15/" 1 "/,, 15h. 113/ "/,. 11u 1'/,, 1314 11/2 86261 1.14 35 11/2 X 1/2 x 3/. 1'/2 1 V2 P/. 3/4 3/. 13/3 86262 1.23 35 1'/2 x 11/2 x 1 1 %, 1% 1 "/s 7/. 1/2 Ph 86263 1.38 30 11/2 x 1 /2 X 11. 3/0 113/, Ph 11 s Me Ms 86264 1.50 30 11/2 x 1'/2 x 2 214 23/,. 2 1'/,. 1'/,e 1'/. 86265 2.00 20 2 x 1 x 2 21h 2 2'/. 11/2 15/14 1'/2 86266 2.18 15 2 x 1'/4 x 2 2'/, 2'h 21/4 1'/2 Pas 11/2 86267 2.31 15 2 x 11/2 x '/2 1'/2 Phs 17/4 3/4 "As 15/o 86268 1.50 30 2 x 11/2 x 3/4 15/. 11/2 115he 7/, 3/4 1/ 86269 1.61 25 2 x 112 x 1 13/4 15/, 2 1 7/e 15/a 86270 1.65 20 2 x 11/2 x 112 21h1 115/, 23/14 15/14 Phe On 86272 2.03 20 2 X 1'h x 2 21/4 23/,, 21/4 1'/2 1'/ 4 1 1/2 86273 2.37 15 2 x 2 x'/2 11/2 112 P/. 3/4 3/. 15he 86222 1.50 30 2 x 2 x 3h 15/a 15/s 115/,s 7/e 7/. Ph 86223 1.67 20 2 x 2 x 1 13/4 1/4 2 1 1 15h. 86224 1.91 20 2 x 2 X 11/4 12/e 11/2 2'6 11/2 1'b Pia 86225 2.05 20 2 x 2 x 1'/2 2 2 23/14 1'/. 11/4 1'/2 86226 2.11 15 2 X 2 x 2'/2 25h 25/. 21s 1/4 17/a 176e 86227 3.67 10 2'h X 2 x 3/4 13/4 15/e 25/,, 56 7/e 1/4 86274 2.22 15 5h 1'/, 86257 1.03 40 Ph x 1 V. x 3/4 1'/2 P/„ 13/4 3/4 3/4 13/,. 86258 1.10 40 11/2 x 11/4 X 1 15h 1'he P3/„ 7/, 7/e 112 86259 1.31 30 1'/2 x 11. x 2 2'/,. 2'h 2 17/14 17/12 11/4 86260 1.94 20 1'h x 11/2 x'/2 17/,4 13/44 1 "/, ,1/n 11,, • INCORPORATED CDRCNI, cA • (osI rn.5599 FIG.200 ADJUSTABLE BAND HANGER Size Range —1/2 thru 8 inch pipe. Material — Carbon Steel, Mil. Galvanized to G-90 specifications. Function — For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features • (1/2 thru 2 inch) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. • (2-1/2 thru 8 inch) Spring tension on nut holds it securely in hanger before installation. Adjus nut is easily removed. Approvals — Underwriters' Laborato (1/2" thru 8") in the U.S. (UL) and CO. for Steel and CPVC plastic pipe and Fadt. Mutual Engineering approved (3/4" thru - Conforms to Federal Specifications WW-H-171E, Type 10, and Manufacturers Standardization Society SP-69, type 10. Maximum Temperature - 650°F. Finish — Mil. Galvanized and Stainless Steel. Order By — Figure number and pipe size. PIPE ROD SIZE SIZE Inch Metric* 1/2 3/8 8mm or iomm 3/4 3/8 8mm or lOmm 1 3/8 8mm or lOmm 1-1/4 3/8 8mm or 10mm 1-1/2 3/8 8mm or 10mm 2 3/8 8mm or l0uun 2-1/2 3/8 10mm 3 3/8 lOnun 3-1/2 3/8 10mm 4 3/8 _10mm 5 1/2 12mm 6 1/2 12ntm 8 1/2 12nuu ' Order Pig, 200 M A B 3-1/8 2-5/8 3-1/8 2-1/2 3-3/8 2-5/8 3-3/4 2-7/8 3-7/8 2-7/8 4-1/2 3 5-5/8 4-1/8 5-7/8 4 7-3/8 5-1/4 7,3/8 5 9-1/8 6-1/4 10-1/8' 6-3/4 13-1/8 8-3/4 MAX. REC. APPROX. LOAD LBS. WT./100 400 11 400 11 400 12 400 400 400 600 600 600 1000 1250 1250 1250 13 14 15 27 29 34 35 66 73 136 1— 2 inch pipe 1/2 - 3/4 inch pipe 2 1/2 - 8 inch pipe 79 Model Rod Size Shk Dia Shk Lgth 20 GST .750 1/4-20 1/4 3/4 21 GST 100 1/4-20 fl 1 22 GST 200 1/4-20 1/4 2 23 GST 300 1/4-20 1/4 8 24 • GST 600 1/4-20 1/4 6 Wood SAMMYS Box quantity 100 except as noted with this marking (♦) ♦ Box quantity 50 See page 13 for Stainless Steel 0„ e„ en Item Item # Model Rod Size Shk Dia Shk Lgth RI Test Load, Ib. t1L Test Load, lb. UIFM Pipe Size Actual Pullout 10 GST .75 3/8-16 1/4 3/4 5644 - 6 Ry 11 GST 10 3/8-18 1/4 1 210# - 7/16 0SB 670# - 3/4r Ply 12 GST 20 3/8-16 1/4 2 940# 850k 3/4-21/2 1760# - Fir 27 • GST25.380 3/8-16 3/8 21/2 1500# 4 2113#-Fir' 13 GST 30 3/8-16 1/4 3 1475# 1500# 3/4-4 2060# - Fir 403 • GST 40 3/8-16 1/4 .4 2180# - Fir 14• GST 60 3/8-16 1/4 3 . 2210#-Fr # Model Rod Size Shk Dia Shk Lgth Actual Pullout nacw0�eloq Note:thensswa.asr.mt for screws with Matap Installatio; 8 ♦ GST 2 1/2-13 1/4 2 1760# -Fir 06 • GST 2.5-38 1/2-13 3/8 21/2 2113# - Fr 15•- GST3 1/2-13 1/4 3 2275#-Fir 16• GST4 1/2-13 1/4 4 ' 2180#-Fr 17 • GST 6 1/2-13 1/4 6 2230# - Fr See Page 5 for installation instructions. Wood Flooded linarPli w Woad Joist • be Fri/Minimum 2" Imdmenl Into base .� material for NFPA 13 compliance TGIJoist /Truss Consult truss mawtacbserfor recommended Installation part. (See"SpeclalNoWn" on "ogee f • •+ Sammy Double Sheetrock Gelling In 1f you don't see n, call us at 1.883.773.0001 4 Wood - Sammys Note: Screws less than 2" itt length will be plated yellow. Greater than 2" are clear zinc per ASTM8633111 S Installation per NFPA 13 Lower lace of es beam or joist Not less ken r nominal width E (11n") / Sammy Far vertical use. Install Inc center of lower face. 1 8 Note: Must be installed with appropriate nut driver to comply with warranty. • SWG See page 13 for Stainless Steel UL Test Load, Ib. If faskMng through gusset Flares, use the SWD 20 (sea page 5) e. Installations S WOOD INSTALLATION INSTRUCTIONS GST & SWG -See diagram figures 1-4,11-14 on page 18 and 19. (self drilling & self -tapping Into wood) Step 1: Insert the appropriate nut driver into a 3/8" or 1/2" portable drill: (a) Use #14 for GST for 3/8" and 1/4" rod; (b) use #14SW for SWG, and for GST for 1/2" rod. Step 2: Insert the screw into the nut driver. Now you are ready to install the screw. Step 3: Position drill and begin installation: (a) for installing GST drill should be in a vertical position; (b) for installing SWG drill should be in a horizontal position at a right angle to the structural member. Step 4: When the nut driver spins freely on the cap of the screw installation is complete. Step 5: Screw is now ready to receive 1/4°, 3/8°, 1/2° or metric all thread rod or bolt stock. Wood SIDEWINDERS Box quantity 100 except as noted with this marking (♦) • Box quantity 50 Actual Shear/Pullout Note: Screws less than 2"in length will be plated yellow. Greater than 2" are clear zinc per ASTMB633111 TGI Joist / Truss Consort truss manufacturer for recommended halatiMion point. (See -Special Notes' an "MN ri Not less than 2" nominal width (11/21 up to 31r1",plpa; not Ins than 3" nominal width 4" & 5" pipe Installation per NFPA 13 Minimum 21/r from bottom for branch fires Mbilmum 3" from ' bottom for main fines. Exception: This nquke ment shall not apply to 2" or tricker nailing scope resting on top of steel beans. Eye protection should be wom at all times when install- ing this product Note: Must be installed with appropriate nut driver to comply with warranty. Wood - Sidewinders 5 TUBE & CONDUIT F . Dyna-Thread® Full. Line Sch-40. Replacement Dyne -Thread' offers the life expectancy of Sch-40 with superior hydraulics and greater value. Dyna-Tluead sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Comparison to Schedule 4.^- • Dyna-Thread's inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. And, when used in combination with Dyna-Flow pipe, down sizing often occurs. • Dyna-Thread is fully listed and approved by UL, ULC, and FM for fire sprinkler applications. • The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. • The consistent quality of steel used to make Dyne -Thread facilitates smooth threading and lower maintenance costs. • The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. • With its increased strength and lighter weight, Dyna-Thread reduces :hstallation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna- Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, ABF". In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Micmbiologicaily Influenced corrosion (MIC) when the First Sprinkler System is first installed. Specifications NPS Nominal ED. M. WL pin NW) Po/ Wwf1(2i') WADI (241 MI (25• kt mm In; mm Least Kg4ri Lbt4t Kg4n UJ? Llw Kg L* Kg Lbs; Kg 1 • 1.080 1.330 1.75 70 1955 25 27.4 20 2.60 70 887 1 ' 1.408 1.870 2.54 51 2002 32 358 2.8 3.78 51 908 144• 1.639 2.290 3.22 44 2115 40 41.6 3.4 4.79 44 959 2' 2.104 3.050 1 1 50 53'4 45 6.80 30 871 two Flow Contra/ tallied ruDE 8 coNourr 2234 1013 2288 1038 2418 1097 1' 996 232 1 2 108 251 11 103 Comparison to L.W.T. Pipes • More wall thickness it the thread (CRR=1.00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. • Unlike ligbtwall threadable pipe, Dyna-Thread has no thread gauge warning. • Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. • Dyna-Thread is safer to weld on. • • Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified Specifications & Approvals Super 40/Dyna-Thread pipe is manufactured to meet: AST M A-135, .4-- Grade A and is in compliance with NFPA-13. All sizes of Super 40/Dyna- Thread are rated at 300 ' workin Ps r g pressure. Super 40/Dyna-TLread is UL and ULC Listed for wet, dry deluge and pre -action sprinkler systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be "hot -dip" galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll -grooved, and plain -end fittings. (See listing information). 16100 S. Lathrop • Harvey, IL 60426 11350 Norcom Ad. • Philadelphia, PA 19154 2525 N. 27 th Ave. • Phoenix, AZ 85009 Customer Service: (800) 882-5543 Fax 708-339-1806 S3-3 TUBE & CONDUIT . Dyna-Flow® ( :.High Strength Steel Pipe The original high -strength Iightwall sprinkler pipe with hydraulics superior, to Schedule-10. Dyna-Flow pipe is the "original" high - strength Iightwall sprinkler pipe. Dyna- Flow has outstanding hydraulic capabilities and is recognized as the most popular alternative to Schedule-10 pipe. Lightweight, easy to cut and easy to handle for installation: Dyna-Flow is a valuable addition to any fire protection system. Superior Hydraulics With an inside diameter of up to 11% larger than Schedulo-40 and up to 7•% larger than Schedule-10, Dyna-Flow pipe hydraulics are exceptional. Larger LD.s enable Dyna-Flow, and related components, to be down -sized within the system, thus increasing the potential for job cost savings. For complete Hazen - Williams charts, refer to "Dyna-Flow Hydraulic Data Tables." Coatings & Fabrication Dyna-Flow products are coated with an environmentally approved and specially formulated modified -acrylic or water -based coating. This durable coating is paintable. The black coating acts as an excellent primer and is resistant to weathering and U.V. degradation from outdoor storage. Metallurgical properties provide excellent fabrication characteristics for end prep finishes, welding and roll grooving. There is no special process or equipment needed for fabrication and installation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF". In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed 14 mm In; mm LbsftKgmn 1' 1.191 0.830 30.3 1.2 1.536 1.059 39.0 1.6 25 1A' 32 1i' 1.728 40 43.9 r 2.203 50 56.0 251' 2.703 65 68.7 3 3.314 80 84.2 4' 4.310 90 109.5 Specifications MPS Nemiaal I.D. WI. WL (1120 Filled) Pr;t WIA.ID (21') Wall (2/') w'va (251 LM4tKp'm Lift Os; Kg Os; Kg LbfKg 1.31 91 1,586 1,812 1,888 1.95 91 719 822 858 1.87 . 61 1,356 1,550 1,615 278 61 615 703 733 1.667 2.71 61 2,135 2,440 2,542 2.5 4.03 61 968 1107 1153 2.104 3.79 37 1,634 1,868 1,946 3.1 5.64 37 741 847 883 2.564 5.10 30 1,615 1,846 1,923 3.8 7.59 30 733 837 872 3.387 7.18 10 lass 4.473 10.88 6.7 16.18 19 1,351 1,544 19 613 7a0 19 1,784 2,039 19 809 925 1,608 729 2,124 963 Specifications & Approvals Dyna-Flow/Super Flo pipe is manufac- tured to meet ASTM A-795 Type 13, Grade A and rs n compliance with NFPA-I3 and NFPA-14. All sizes of Dyna Flow/Super Flo are UL Listed, FM Approved and ULC Listed. Listed Approved Listed Dyna-Flow/Super Flo is UL/ULC Listed for use with roll grooved, plain -end couplings, and welded joints for wet, dry, preaction and deluge systems. It is FM Approved for roll grooved, plain -end and welded joints for wet systems. Refer to appropriate documentation for up-to-date listing and approval information. Dyna- Flow/Super Flo is now available "hot - dip" galvanized and has been specifically approved: by FM for dry systems uses. Additional Benefits • Lightweight and easy to install, resulting in more efficient use of your freight and labor dollars. • Provides stability needed to comply with standard hanger spacing (15 ft O.C.) per NFPA. • Available in Standard lengths for your convenience, or can be ordered in custom lengths upon approval. • Fast cutting and welding, as well as easy roll grooving and end preparation. • Available in Factory roll grooved form for quicker shop turnaround. • Clean, durable mill coating provides longer "shelf life" and acts as an excellent primer for custom paint applications. Y'qCO/FMwControl 7 (J ��IC^ „1 16100 S. Lathrop • Harvey, IL 60426 11350 Norcom Rd. • Philadelphia, PA 19154 TUDC a CONDUIT 2525 N. 27 th Ave. • Phoenix, AZ 85009 Customer Service: (800) 882-5543 Fax 708-339-1806 S2-3 Sch. 10 and Sch. 40 Fully UL listed and FVI approved sprinkler pipe QUALITY ASSURANCE American Tube & Pipe is the first manufacturer to offer UL listed, FM approved Sch.10 and Sch. 40 sprinkler pipe. Although these products do not require separate approvals, American Tube & Pipe gives you the extra quality assurance you demand. Our Sch.10 (1t/A"-4") pipe and Sch. 40 (1"-2") pi, have passed the same thorough lab ing as our other listed pipe produc and receive periodic mill inspectio from both UL and FM agents toe consistent quality. AMERICAPI MADE t- ere Meets "Buy American" requirements and is available through distributors nationwide. SPECIF'te;,f1T°&�A$� 2 h/"" 3° 4" *6" *8° 1" 1/i Ph° 2" 2.875 3.500 4.500 6.625 8.625 1.315 1.660 1.900 2.375 73.0 88.9 114.3 168.3 219.1 33.4 42.2 48.3 60.3 SPECIFICATIONS American Tube Sch. 40 pi the f.. a i in compliance with d wing. A135 ASTM A795 NFPA 13 Listed approved Both pipe products also meet gent requirements for the fo • Welded I.t . strin- wing tests: ets y rostatic Pressure ❑ Side WaR Rupture • Vibration Test • - <00 A" lna 2.635 3.260 4.260 6.357 8.249 1.049 1.380 1.610 2h067 66.9 82.8 108.2 161.5 209.5 .120 .120 .120 .134 .188 SCHEDULE 40 w!PE 26.6 35.1 52.5 3.05 3.05 3.05 3.40 4.80 SUPERIOR COATING Our exclusive "Diamond Coat" U.V. cured acrylic finish offers a clean, durable surface that outlasts typical lacquers. It is also paint -ready for cus- tom color applications without special preparation. GALVANIZED PIPE American Tube & Pipe products can be "hot -dip" galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications of ASTM A795 or A53. 3.53 4.33 5.61 9.29 16.94 1.61 1.97 2.55 4.22 7.69 .133 3.38 1.68 .76 .140 3.56 2.27 1.03 .145 3.68 2.72 1.24 'The 6'm,arSchedule 10 offered by .154 3.91 3.65 1.66 American Tube & Pipe is sold under license from another domestic manufacturer and meets ASTM A135 and NFPA 13. 2525 N. 27th Ave. 101 E. Broadway Phoenix, AZ 85009 Kokomo, IN 46901 6.95 5.000 Customer Service 1-800-877-8823 1-602-272-6606 FAX 602-269-1324 19 19 19 10 7 AMERIt,A' NTIREAPIPE- CENTRAL 705 4-01 Flexible Coupling Figure 705 Tyco Fire Products --- www.tyco-grooved.com 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 --- USA Customer Service/Sales: Tel: (215) 362-0700 / Fax: (215) 362-5385 Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Product Description See Fire Protection Submittal Sheet for pressure rating and Listing and Approval information The Figure 705 Flexible Coupling is capable of pressures up to 300 psig depending on pipe size and wall thickness. It provides a dependable method of Joining pipe and is suitable for use in a variety of applications. Rigid Couplings are recommended for dry pipe and freezer applications. Technical Data Figure: 705 Sizes: I %a' -12' Approvals: UL, FM, and ULC; See Fire Protection Submittal Sheet for exact Listing / Approval Info. Manufacturing Source: Domestic Rousing: Ductile iron conforming to ASTM A-536, Grade 65-45-12 Protective Coatings: • Non -lead orange paint • Hot dipped galvanized conforming to ASTM A-153 Bolt/Nuts: Track Head Bolts - conforming to ASTM A-183, Zinc Plated, (Min. Tensile =110,000 psi) Gasket: (specify when ordering) • Grade A EPDMA violet color code ambient to +150°F (466°C) for fire protection systems. Not recommended for hot water systems. • Tri-seal (Grade E EPDM), green color code for use in dry pipe or freezer systems. • Prelubricated (Grade A EPDMA) • Prelubricated Tri-seal (Grade E EPDM) (See Gasket Grades and Recommendations Sheet for aid in selecting proper gasket) di Ordering Procedure Ordering In ormation: When placing an order, indicate the full product name. Please specify the quantity, figure number, type of gasket, EPDM 'A' or "E" Tri-Seal, and size. Availability and Service: Grooved Piping Products: valves, accessories and other products are available throughout the U.S., Canada, and internationally, through a network cf distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in rraterial and workmanship when paid for and properly installed CENTRAL Grooved Piping Products and maintained under normal use and service: This warranty will expire ten (10) years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILTTYAND FITNESS FOR A PARTICULAR PURPOSE No. 18-2.0 Figure 705 Grooved Coupling Pipe Max •t Max.f Max.t 0.D. End Gap Pressure End load Size Inches Inches psi Lbs. mm mm kPa pr 649 2,837 76.1mm 1.660 42.2 1.900 48.3 2.375 60,3 2.875 73.0 3.000 76.1 3.500 88.9 4.500 114.3 5.563 141.3 10.750 273.1 12.750 323.9 0.13 3.3 0.13 3.3 0.13 3.3 0.13 3.3 0.13 3.3 0.13 0.25 6.4 0.25 0.25 6.4 0.25 6.4 0.25 6.4 0.25 6.4 0.25 6.4 300 2,068 300 2,068 300 2,068 300 2,968 300 2,068 300 300 2,068 300 300 2,068 300 2,068 300 2,068 250 1,724 250 1,724 Dimensions Deflection t A 8 C °Per Inches/ Inches Inches Inches Foot mm mm mm Coupling mm 2.53 64.3 850 2.75 3,781 69.9 1,328 3.25 5,907 82.6 1,947 3.69 8,660 93.7 2°-29' 2,120 9,430 2,885 12,832 4,769 21,21.3 7,288 32,417 9,950 44,258 10,336 45,975 17,519 77,925 22,679 100,876 141,905 3.97 100.8 4.38 111.3 5.68 144.3 6.88 174.8 7.75 196.9 7.91 200.9 10.19 258.8 12.69 322.3 14.91 378.7 " Maximum available gap between pipe ends. Minimum gap = 0. t Maximum pressure and end load are total from all loads based on standard weight steel pipe. Pressure ratings and end Toads may differ on other pipe materials and/or wall thickness. Contact Tyco lire Products for details. See Fire Protection Equipment Submittal Sheet for Listing and Approval pressure ratings. "Metric bolt size used On 76.1mm and 165.1mm couplings. t Max End Gap and Deflection is for cut grooved standard weight pipe. Values for roll grooved pipe will be %: that of cut grooved. 4.19 106.4 4.43 112.5 4.84 122.9 5.50 139.7 5.75 146.1 6.50 165.1 7.75 10.68 271.3 10.68 271.3 13.56 344.4 16.38 416.1 18.84 478.5 1.81 46.0 1.81 46.0 1.88 47.8 1.88 47.8 1.88 47.8 1.88 2.06 52.3 2.06 2.06 52.3 2.06 52.3 2.47 62.7 2.63 66.8 2.63 66.8 4°-19' 2°-35' 0.90 75.0 0.79 65.8 0.63 52.5 0.52 43.3 0.43 35.8 0.67 55.8 0.54 45.0 0.46 - 38.3 0.45 37.5 0.35 29.2 Bolt Size" Dia. x Lg. Net Wt Lbs. Kg. 3/a' x 3/e' x 2Yi x 2' M12x76 Vz x3' '/z' x 3' 5/e' x 31/4' M16x83 '/e' x 3Vi 1' x 6'/i 1.5 7.0 1.6 0.7 1.7 0.8 2.0 0.9 7.1 3.2 7.1 3.2 14.5 6.6 General Notes: It is the Designers responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded. Always read and understand the Installation instructions (IH-1000). Never remove any piping component nor correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. 0.28 23.3 023 19.2 28.0 12.7 36.5 16.6 Y'4JCO/Flow Control /Tyco Fire Products Certified Company CENTRAL GROOVED FITTINGS 4-01 Grooved Fittings Tyco Fire Products --- www.tyco-grooved.com 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 -- USA Customer Service/Sales: Tel: (215) 362-0700 r Fax: (215) 362-5385 Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 CENTRAL Grooved Piping Products lilaGeneral Description kCSee Fire Protection Submittal Sheet for pressure rating and Listing and Approval information Grooved fittings provide an economical and efficient method of changing direction, adding an outlet, reducing, or capping grooved piping systems. Grooved fittings are available in durable ductile Iron or fabricated steel as indicated. Friction Resistance (Expressed as Equivalent Straight Pipe) Elbows Tee Size 90° 45° Branch Run Inches Feet Feet Feet Feet mm Meters Meters Meters Meters 1%< 1.9 1.0 4.8 1.9 42.2 0.6 0.3 1.5 0.6 1 %z 2.3 1.2 5.8 2.3 48.3 0.7 0.4 1.8 0.7 2 3.2 1.6 8.0 3.2 60.3 1.0 0.5 2.5 1.0 21 3.9 2.0 9.8 3.9 73.0 1.2 0.6 3.0 1.2 76.1 4.1 2.1 10.3 4.1 1.2 0.6 3.1 1.2 3 4.9 2.4 12.2 4.9 88.9 1.5 0.7 3.7 1.5 4 6.5 3.3 16.3 6.5 114.3 2.0 1.0 5.0 2.0 5 8.2 4.1 20.5 8.2 141.3 2.5 1.3 6.3 2.5 165.1 9.5 4.8.23.8 9.5 2.9 1.4 7.2 2.9 6 9.9 5.0 24.8 9.9 168.3 3.0 1.5 7.6 3.0 8 13.1 6.6 32.8 13.1 219.1 4.0 2.0 10.0 4.0 12 19.9 9.9 49.7 19.9 323.4 6.1 3.0 15.1 6.1 Technical Data Sizes: 1 /' -12' Maximum Working Pressure: See specific data sheet for rating of coupling being used. Approvals: UL, FM, and ULC Note: Selected fittings are Listed/ Approved for fire protection service. See Fire Protection Submittal Sheet for exact Usti ng/Approval Information. Manufacture Source: Domestic or as noted. Material: Cast: Figures: 201,210, 219, and 260 Ductile iron, conforming to ASTM A-536 Grade 65-45-12 Fabricated Steel: Figures: 301, 302, 303, 312, 313, 321, 327, 341 and 350 Carbon Steel, (Sizes 1 %: - 6' are Schedule 40); (Sizes 8' - 12' are Schedule 30), confoming to ASTM A-53 Grade B Figure: 326 Carbon Steel,Schedule 10, conforming to ASTM A-135 Type E, Grade B Protective Coatings: • Non -lead orange paint • Hot dipped galvanized conforming to ASTM .A-153 Ordering Procedure Ordering In vrmation: When placing an order, indicate the full product name. Please specify the quantity, figure number, wall thickness, and size. Availability and Service: Grooved Piping Products, valves, accessories and other products are available throughout the U.S., Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. r„ Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. No. 18-1.0 Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been C toE Chit Figure 201 CIDE C to E Figure 210 i-C to 6-1 CtoE Figure 219 E toE -I f- Figure 260 Nominal Size 1Yi 76.1 mm 3' installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE INUEUOFANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND RTNESS FORA PARTICULAR PURPOSE, Figures 201, 210, 219, and 260 Fig. 201 - 45° Elbow C to E Appx. Wt. Inches Lbs. Kg. 0.9 0.4 1.1 0.5 1.8 0.8 mm 1.75° 44.5 1.75° 44.5 2.00° 50.8 2 25° 57.2 2 25° 572 2.50° 63.5 2.2 1.0 2.2 1.0 3.5 1.6 Fig. 210 - 90° Elbow C to E Inches mm 2.75° 69.9 2.75° 69.9 3.25° 82.6 3.75° 95.3 3.75° 95.3 4.25' 108.0 Appx. Wt. Lbs. Kg. 1.0 0.5 1.2 0.5 2.0 ' 0.9 3.0 1.4 3.0 1.4 4.5 2.0 Fig. 219 - Tee Fig. 260t- End Cap C to E Appx Wt. E to E Inches Lbs. Inches mm.. Kg. mm 2.75° 1.4 0.88° 69.9 0.6 224 2.75° 1.8 0.88° 69.9 0.8 22.4 3.25' 82.6 3.75° 95.3 3.75° 95.3 4.25° 108.0 2.7 1.2 5.8 2.6 5.8 2.6 7.0 3.2 Appx Wt. Lbs. Kg. 0.4 0.2 0.6 0.3 0.88" 22.4 0.88° 22.4 0.94° 23.9 0.9 0.9 0.9 0.4 1.1 0.5 0.88° 22.4 nod 5.2 5.00° 8.5 5.004 11.8 1.00° 2.6 76.2 2.4 127.0 3.9 127.0 5.4 25.4 1.2 3.25d 8.5 5.50° 13.5 5.50° 17.0 1.00° 5.0 82.6 3.9 139.7 6.1 139.7 7.7 25.4 2.3 3.50° 12.0 6.50° 18.5 6.50° 26.0 1.00° 7.5 88.9 5.4 165.1 8.4 165.1 11.8 25.4 3.4 3.50° 12.0 6.50° 18.5 6.50° 26.0 1.00° 7.5 88.9 5.4 165.1 8.4 165.1 11.8 25.4 3.4 8 4.25° 23.0 7.75d 36.5 7.75° 45.0 1.19° 12.8 108.0 10.4 196.9 16.6 196.9 20.4 30.2 5.8 4.750 31.0 9.00d" 60.0 9.00""" 72.1 1.25° 20.0 120.7 14.1 228.6 27.2 228.6 32.7 31.8 9.1 12° 133.4 18.1 11254.0 30.4 12� " 42.0 31.8 16.3 • d - These fittings are available in domes is ductile iron. All 300 series sizes am fabricated steel. - These sizes can also be ordered in the Figure 110 which Is cast ductile iron purchased from a foreign supplier. 1 - These sizes can also be ordered in the Figure 111 which is cast ductile iron purchased from a foreign supplier. " - These sizes can also be ordered in the Figure 120 which is cast ductile iron purchased form a foreign supplier. t - Sizes 1% thru 12" are available with''/' and 1" tap plug. 1.1 0.5 4° 5' 165.1 mm 6' 10° r 132 O0"tuo)77.ss99 FIG.909 NO -THREAD ' SWIVEL SWAY BRACE ATTACHMENT Size Range —1 and 1-1/4 inch bracing pipe. For brace pipe sizes larger than 1-1/4 inch use Tolco Fig. 980. Material — Carbon Steel, hardened cone point engaging screw. Function — The structural component of a sway and seismic bracing system. Features — • Nothreading of the bracing pipe is required. • Open design allows for easy inspection of pipe engagement. • All steel construction eliminates deficiencies a n4atf with malleable type attachments. • Fastener can be mounted to all surface angles. Application Note - The Fig. 909 is used in conjunction with the Tolco Fig. 1000 "Fast Clamp!'" ", Fig. 2001, or Fig. 4(A) pipe clamp, and joined together with bracing pipe. Install per NFPA #13 and/or Tolco's State of California OSHPD Approved Seismic Restraint Manual. Installation — Extend bracing pipe through opening. Tighten cone point engaging screw until head bottoms out. Approvals — Underwriters Laboratories Listed per 203A (UL). Approved by State of California Office of Statewide Health, Planning and Development (OSHPD). Finish — Plain, Electro Galvanized and HDG. Order By — Figure number, pipe size and finish. Important Note — The Fig. 909 is precision manufactured to perform its function as a critical component of a complete bracing a wmbly. To ensure performance, the U.L. Listing requires that the Fig. 909 must be used only with other Tolco bracing products. NATIONAL AND INTERNATIONAL PATENT APPLICATIONS IN PROCESS. PIPE SIZE A B 1 6 1-5/8 1-1/4 6 1-5/8 * Available with hole C MAX. HORIZONTAL HORIZONTAL DESIGN DESIGN LOAD LB3 H• LOAD LBS. W/WASHER 17/32 2015 2765 17/32 2015 2765 97 sizes to accommodate up to 3/4" fastener. onsult Factory MAX. APPROX. WT./100 91 State of California OSHPD APPROVED Standard washer (Fig.115) required for 2765 Ib. design load 22 /ItCCNPOHATED caPOwL cA•(999) ]97d599 FIG. 4A PIPE CLAMP FOR SWAY BRACING Size Range-4 thru 8 inch pipe. (For sizes l/2thru 3-1/2 inch, see Fig. 4 Pipe Clamp.) Material - Carbon Steel Function - Used as part of a sway bracing system. Differs from Fig. 413ipe Clamp in that the bolt holes are designed to match the holes in Sway Brace Fittings (see Fig. 910/975 series). Approvals - Listed by Underwriters'Labomtories 4 thru 8 inch. Approved by Factory Mutual Engineering 4 thru 8 inch. Maximum Temperature - 750°F Finish - Plain, Electro-Galvanized, HDG, and Stainless SteeL Order By - Figure number, pipe size, and finish. PIPE SIZE 4 APPROX. BOLT WEHTA COC SIZE PER II)O 8-1/2 5/8 3-5/16 1/4x1-1/4 2x2 221 6 11-1/4 3/4 4-7 8 8x1- 2 x2- 2 513 FIG. 4F STANDARD PIPE CLAMP WITH FELT LINING Size Range - 1/2 thru 2-1/2 inch copper tubing. Fig. 4 can be specially ordered with felt pads bonded to damp. This eliminates costly field time to isolate pipe from clamp. When ordering allow for 3/16" felt on each half clamp. Specify Fig. 4F. Features - Utilizes a basic hanger design which is Underwriters' Laboratories listed and Factory Mutual Engineering approved, and conforms to Federal Specification WW-H-171E, type 4, and Manufacturers Standardization Society SP-69, type 4. The only change is the addition of feltlining. Maximum Temperature - 650°F Teo0 *CORPORATE, ooaouti CA.lsoslrnasss FIG.2001 SWAY BRACE ATTACHMENT Size Range — Pipe sizes to be braced 2-1/2 thru 8 inch, all steel schedules, copper, plastic, FRP, cast iron, and ductile iron. (Consult factory when bracing pipe other than steel.) The Fig. 2001 accepts brace pipe sizes land 1-1/4 inch steel, sch.i0 thru sch.40. Material _ Carbon Steel. Function — For bracing pipe against sway and caicmic disturbance. The pipe attachment component of a sway brace system:: Fig. 2o01 is used in conjunction with Tolco 900 Series . sway brace: attachments and joined together with bracing pipe. Install per. NFPA #13 and/or Tolco's State of California OSHPD Approved Seismic Restraint Manual. Features - • Unique design will not damage thin wall, plastic, copper or ductile iron pipe. • Easy verification of proper installation by tightening bolts until ears touch. • Installation — Place Fig. 2001 over pipe to be . braced. Slide .bracing pipe through attachment (1" min.) and tighten bolts until ears touch Approvals - Underwriters Laboratories Listed per 203A (UL). Finish — Plain, Electro-Galvanized, and. HDG. Order.13y - Figure number, pipe size to be braced and pipe size used for bracing, and finish. Important Note = The Fig. 2001 is precision manufactured to perform its function as a critical component of a complete bracing assembly. - To ensure performance, the U.L. Listing requires that the Fig. 2001 must be used only with other Tolco bracing products. NATIONAL AND INTERNATIONAL PATENT APPLICATIONS IN PROCESS. Tighten bolts until ears touch 137 IMax. Horizontal Design Load 2,015 Ibs. I