HomeMy WebLinkAboutX2008-2315 - Misca
Dr.
CITY OF NEWPORT BEACH
BUILDING DEPARTMENT
3300 NEWPORT BLVD.
P.O.BOX 1768, NEWPORT BEACH, CA
(949) 644-3275
TENANT IMPROVEMENT CORRECTIONS
Project Description: 7' 3" high directional sign
Project Address: 1 Hoag Hospital
Plan Check No.: 2057-2008 Date Filed: 10/30/2008 No. Stories: N/A
Use: Commercial Occupancy: U Const. Type: V - B
Architect/Engineer: Aghjan Yakob Phone: (661) 259-0700
Owner: Hoag Hospital
Checked by: Ali Naji
X
1st Check
X
2nd Check
Phone: (949) 765 4486 Submitted Valuation: 5500
Phone: (949) 644-3292 Permit Valuation: 5500
3rd Check* 4th Check*
*NOTE: Do not resubmit. Call plan check engineer
for in -person recheck.
WARNING: PLAN CHECK EXPIRES 180 DAYS AFTER SUBMITTAL.
THIS PLAN CHECK EXPIRES ON: April 28TH, 2008
Approval of plans and specifications does not permit violation of any section of the Building Code
or other City ordinances or State law.
This plan check is according to 2007 California Building Code.
• Make all corrections listed below.
• DO NOT re=submit after the third check. Call plan check engineer and schedule in -person recheck.
• Return this correction sheet and check prints with corrected plans.
• Provide a correction response sheet to indicate how each correction was resolved.
GENERAL
1. Approval is required from:
Building Department
Planning Department
Include the building type of construction and the occupancy classification as listed above on the title
sheet.
IsTRecheck: Correction still not resolved.
Include a sheet index on the title sheet. List all sheets.
4IsTRecheck: Correction still not resolved.
Ali Naji, P.E.
anaii@city.newport-heach.ca.us
3300 Newport Blvd. 1/2 12/04/08
Newport Beach, CA 92658
T: 949.644.3292 F: 949.723.3534
Revise construction details on drawings per structural calculations. Specify depth of proposed
footin.s. Include construction materials specifications on drawings.
Recheck: Correction still not resolved.
esign engineer shall wet stamp & sign the site plan and structural details that are part of
rawings.
41sTRecheck: Correction still not resolved.
Ali Naji, P.E.
anaii n,citv.newoort-beach.ca.us
3300 Newport Blvd. 2/2 12/04/08
Newport Beach, CA 92658
T: 949.644.3292 F: 949.723.3534
Wayne: Mills PI ?#
Valencia, CIA 91355
Sign Design Based on 2007 CBC
Job #
Project
Job Location
INPUT DATA
Exposure category (B, C or D)
JTS_2706
Hoag Cancer Center Pylon
1 Hoag Hvy. Bldg.#47
Newport Beach CA
= C
Importance factor, pg 73, (0.87, 1.0 or 1.15) I = 1 00 Category II
Basic wind speed (3 sec. gust wind) V = 90 mph
Topographic factor (Sec.e 5.7.2, pg 26 & 45) Ka = 1 Flat
Overall Height Above Grade h = 7.25 ft
Vertical dimension (for wall, s = h) s = 7.25 ft
Average horizontal dimension 6 = 2.5 ft
Dimension of return corner LT = 0.6 ft
Moment arm A = 5.5 ft
DESIGN SUMMARY
Max horizontal wind pressure
Max total horizontal force at centroid of base
Max bending moment at centroid of base
ANALYSIS
Velocity pressure
qn = 0.00258 Kh Ka Ke V21
where.
p 25 pet
F = 0.453 kips
= 2.628 ft-kips
14.98 psf
qn c velocity pressure at mean roof height, h. (Eq. 6-15, page 27)
Kn' velocity pressure exposure coefficient ...-. __. evaluated at height, h,(Tab. 6-3, Case 1, pg 79)
Kd = wind directionality factor. (Tab 6-4. for building, page 80)
AI- height of top
0.85
0.85
7.25 ft
Wind Force Case A: resultant force though the Geometric center (Sec 6 5 14 & Fig. 6-20j '
P=gnGC,=
F=pA,
M = F (h - 0.5s) for sign, F (0.65h) for wall
T=
where'. G = gust effect factor. (Sec. 6.5.8, page 26). _
Cr = net force coefficient (Fig. 6-20, page 73)
A,=Bs =
Footing Design
Diameter 1.00 FT
Soil Pressure 100.00 PSF/FT
S1 354.67 PSF
A 1.49 FT
EMBED. 3.80
12" Dia.
Depth =
Base Vertical Pole Design
MOD. Required
S1 0.54
Base Plate
Sq. WI Tube
USE
TS 3x3x1/4"
THICKNESS Requ'red
Thick 0282
stir Plate
USE
8" x 8" x 12" Thick '
Bolt Design Anchor Bolts
TENSION Required USE
Ten 1434
1/2" Dia. x 19" Embed.
Horizontal Pole Design
Torsion = Required
J 176
Sq. St'I Tube
USE
TS 3x3x1/4"
S=2.10
t--o.5"
T=2,811
Allowable = .4`36000=14,400 O.K.
25 psf
0.45
2.83
0.00
0.85
1.60
18.1
kips
ft-kips
ft-kips
ftZ
/72
DATE 10/23/2008
1661.) 259-0700
fl259.- 9+.#(
CABINET 6Y
Jf HENS
----SO DT's TUBE
TS 3+3x1/4'
3/1 D'.
m,�, -CSJ )0(
EL
Cabinet Vertical Pole Design
MOD. Required USE
S1 0.14
12
DIA
1VAT1❑1`I
SO. -EL TUBE
TS 3x3x1/4"
/2" DIA , 18" EMBED.
A:110S BOLLS
-CONSOLIDATED
CONC_ rc=2500
a3 HOOPS @ 6' O.C.
r5) y4 VENTS.
3' CLEAN
r1Ts
ST'L TUBE
'/2" 0. 18" EMBED.
ANCHOR EaLTS, TYE.
�BASL PLATE_
NES
Sq. 5t'1 Tube
TS 3x3x1/4"
5=2.10
r
25379 Wayne Mills PI # 272
Valencia, CA 91355
DATE 10(23/2008
TEL (661) 259-0700
FAX (661) 259-0900
Sign Design Based on 2007 CBC
Job #
Project
Job Location
JTS_2708
Hoag Cancer Center Pylon
1 Hoag Hwy. Bldg. #47
Newport Beach, CA
INPUT DATA
Exposure category (B, C or D)
Importance factor, pg 73, (0.87, 1.0 or 1.15)
Basic wind speed (3 sec. gust wind)
Topographic factor (Sec.6.5.7.2, pg 26 & 45)
Overall Height Above: Grade
Vertical dimension (for wall, s = h)
Average horizontal dimension
Dimension of return confer
Moment arm
DESIGN SUMMARY
Max horizontal wind pressure
Max total horizontal force at certroid of base
Max bending moment at centroid of base
ANALYSIS
Velocity Oressine
-qh 10.00258 KbKa KdVrI
where:
qh = telocity pressure at mean roof height, h. (Eq. 6-15, Page 27)
Kh = velocity pressure exposure coefficient
evaluated at height, h,(Tab. 6-3, Case 1, pg 79)
K4 = wind directionany factor. (Tab. 64, for building, page 80)
h = height of top
V
KY
h
s
B
4
A
P =
F =
M =
C
1.00 Category II
90 mph
1 Flat
7.25 ft
7.25 R
2.5 ft
0.6 x
5.5 0
0.453
2.828
= 14.58 pet
25 pet
ps
OJdps
= 0.16
= 0.86
= 72S R
Wind Force Case A: resultant force thouah One GarreUM center (Sec. 6.5.14 8 Fig. 8-20)
P = GOy=
F=pA,
M - F (h -0.5s) for sign, F (0.55h) for wag
T=
where: G = gust effect factor. (Sec. 6.5.8, page 26).
C.= net fate coefficient (Fig. 6-20, page 73)
A =Bs
Footing Design
Diameter
Soil Pressure
Si
A
EMBED.
1.00 FT
100.00 PSF/FT
354.67 PSF
1.49 FT
3.80
it Dia.
Depth =
4'-0'
Base Vertical Pole Design
MOD. Regaled
Si 0.54
Base Plate
Sq. SO Tube
use
TS 3x3x1/4'
SCi Rate
THICKNESS Required USE
Thick 0.282
S' x 8'x 12' Thick
Bolt Design Anchor cots
TENSION Reglwed USE
Ten 1434
12' Dia. t 111" Embed.
Horizontal Pole Design
Torsion = Required
J 176
Sq. Sn Tube
USE
TS 3x3xIMP
s
S=2.1
tw3.5'
T=2,811
Allowable= A'36000=14,400 O.K
26 Pat
0.46
2.63
0.00
O.85
1.60
10.1
lops
It-Idps
ft-kips
%O ESSi
OF CAOC
4 3'
CABINET BY
OTHERS
ELEVATI❑N
Cabinet Vertical Pole Design
MOD. Required usE
Si 0.14
SO. ST'L TUtjE
TS 3x3x1/4'
1/2" DIA., 18" EMBED.
ANCHOR BOLTS
CONSOLIDATED
CONC. Yc=2500
N3 HOOPS 0 6" O.C.
(5) jJ4 VERTS.
3" CLEAR
NTS
3 16"
YP E70 XX
15 3x3x1/4"
50. ST'L TUBE
1 /2" 0, 18" EMBED.
ANCHOR BOLTS, TYP.
f-A-N BASE PLATE
vLv t=1/2" NTS
Sq. SCI Tube
TS 3x3x1/4'
S=2.10
2C1.2Oo25
[aRTIFICATE OF COMPLIANCE
(Part 1 of 2) OLTG-1-C
PROJECT NAME
HOAG HOSPITAL ADV. TECH
DATE
10/22/08
PROJECT ADDRESS
1 HOAG DRIVE #47
PRINCIPAL DESIGNER - LIGHTING
P.S. SERVICES, INC.
TELEPHONE
714.683.1120
Building Pernik
DOCUMENTATION AUTHOR
P.S. SERVICES, INC.
TELEPHONE
714.683.1120
Checked by/Date
Enforcement Agency Use
IGENERAL INFORMATION
DATE OF PLANS
OUTDOOR LIGHTING ZONE
(✓ One)
I
!_-1 J 74
■ LZ1—.-0 (12 0 L7 i
FUNCTION TYPE
. OUTDOOR LIGHTING
SIGNS ❑ INDOOR SIGNS
OUTDOOR
NEW
MI ADDITIONS
. ALTERATIONS
PHASE OF CONSTRUCTION
CONSTRUCTION
STATEMENT OF COMPLIANCE
I
This Certificate of Compliance lists outdoor lighting system specifications need to comply with Title 24, Parts 1 and 6 of the California Code of
Regulations. This certificate applies only to building lighting requirements.
The documentation preparer hereby certifies that the documental; is
DOCUMENTATION AUTHOR
P.S. SERVICES, INC.
and c
mplete.
DATE
10/22/08
The Principal Lighting Designer hereby certifies that - pr oposed outdoor lighting and signs design represented in this set of construction documents
is consistent with the other compliance forms anworksheets, with the specifications, and with any other calculations submitted with this permit
application. The proposed building has been designed to meet the lighting requirements contained in the applicable parts of Sections 110, 119,130
through 132, 146, and 149 of Title 24, Part 6. Please one:
•
- 0 I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person
responsible for its preparation; and that I am licensed in the State of California as a civil engineer or electrical engineer, or I am a licensed
architect,
® I affirm that I am eligible under the provisions of Divi sion 3 of the Business and Professions Code by section 5537.2 or 6737.3 to sign this
document as the person responsible for its preparation; and that I am a licensed contractor performing this work.
❑ I affirm that I am eligible under the provisions of Division 3 of the ness and Professions Code to sign this document beca use it pertains to a
structure or type of work described as exempt pursuant to u • ess nd e sions Code Sections 5537,5538 and 6737.1.
(These sections of the Business and Professions Code int ' full in t N esidential Manual
PRINCIPAL LIGHTING DESIGNER -NAME
P.S. SERVICES, INC.
SIGNAT�
yilt
DATE
10/22/08
LIC.4
614676
A
INSTRUCTIONS TO APPLICANT OUTDOOR LI GHTING COMPUANCE & WORKSHEETS ( 1 box If worksheet Is included)
For detailed instructions on the use of th is and all Energy Efficiency Standards compliance forms, please refer to the Nonresid ential
Manual published by the Calif omia Energy Commission.
1=f OLTG-1-C
Certificate of Compliance. Required on plans for all submittals for outdoor lighting. Part 2 of 2 may be
incorporated in schedules on the plans.
Either LTG-1-C or OLTG-1-C may be used for signs as follows:
1. Use LTG-1-C if the project consists solely of indoor signs
2. Use LTG-1-C if the project consists of indoor lighting, and outdoor or indoor signs, but no other outdoor lighting.
3. Use OLTG-1-C if the project consists solely of outdoor signs
4. Use OLTG-1-C if the project consists of outdoor lighting, and indoor or outdoor signs, but no other indoor
lighting
❑ OLTG-2-C
LIGHTING COMPLIANCE SUMMARY. Applicable Parts required for ALL outdoor lighting allowances (Except for
Signs)
• OLTG-3-C
AREA CALCULATIONS WORKSHEETS. Applicable parts required for all outdoor area calculations.
® OLTG-4-C
SIGN LIGHTING COMPLIANCE. Required for all inter naily and externally illuminated signs, for both indoor and
outdoor signs.
2005 Nonresidential Compliance Forms
April 2005
CERTIFICATE OF COMPLIANCE (Part 2 of 2) OLTG-1-C
PROJECT NAME
HOAG HOSPITAL ADV. TECH
LLighting Schedules on Plans Show that Outdoor Lighting Meets Allowed Lighting Power
for general site illumination on OLTG-2-C Part 1 of 4
• Lighting power allowances
Not Applicable
• Lighting power allowances
for local ordinances or for security multipliers on OLTG-2-C Part 2 of 4
Not Applicable
• Lighting power allowances
for specific applications, other than vehicle service stations with canopies on OLTG-2-C Part 3 of 4
Not Applicable
• Lighting power allowances
for vehicle service station canopies on OLTG-2-C Part 4 of 4
F2 Not Applicable
on OLTG-4-C
Sign lighting compliance
• Not Applicable
Mandatory Measures on Plans Show that Outdoor Lighting Meets Outdoor Lighting Controls and Equipment
Indicate location on plans of Note Blockfor Mandatory Measure
been determined in accordance with § 130(c)1
or
Installed lighting power has
❑ Not Applicable
M All permanently installed
luminaires with lamps rated over 100 watts either have a lamp efficacy of at least 60 lumens per watt or are
§ 132(a)
controlled by a motion sensor
Fa Not Applicable
• All Luminaires with lamps
rated greater than 175 watts in hardscape areas, including parking lots, building entrances, canopies, and
Cutoff Requirements of § 132(b)
all outdoor sales areas meet the
i7 Not Applicable
All permanently installed
outdoor lighting meets the Control Requirements of § 132(c)1
❑ Not Applicable
lots, garages, canopies, and outdoor sales ar eas meet the Multi -Level Li ghting Requirements of § 132(c)2
• Building facades, parking
1 Not Applicable
MANDATORY AUTOMATIC CONTROLS
CONTROL LOCATION
CONTROL
IDENTIFICATION
CONTROL TYPE
Auto Time Switch/Photosensor, etc
AREA CONTROLLED
NOTE TO
FIELD
SIDE
SERVICE
TOGGLE SWITCH
SIDE
SERVICE
TOGGLE SWITCH
2005 Nonresidential Compliance Forms
April 2005
SIGN LIGHTING COMPLIANCE OLTG-4-C
PROJECT NAME
HOAG HOSPITAL ADV. TECH
DATE
10/22/08
Alternative 1 - Lighting Power Allowances
Alternative 2 - For Signs
technologies listed
(Check all that apply)
that ONLY use one or more of the
in M through 5
A
B
C
D I E r G
H I 11
K L
MN
OP
Q
R
5
Sign Symbol or Code
Quantity of Signs
Description or
Location
Allotted Watts
Lamp/ Ballast
Design Watts
High Pressure Sodium
Pulse Start or Ceramic
Metal Halide
Neon and Cold Cathode
Light Emitting Diode
(LED)
Barrier Coat Fluorescent
Lamps (includes most T5
and TB lamps)
CFLs not containing
Medium Screw Base
Sockets
Electronic Ballasts with
Output Frequency of
20kHz or more
Sign Area (ft2)
Internally (I) OR
Externally (E)
Illuminated
Allotted LPD
(12 or2.3)
(W/ft2)
Allotted Watts
(D X F)
Lamp Type
Number of OR
Lineal Feet of Lamps
Number of Ballasts
In Signs
Total Designed
Sign Input watts
Is G Smaller than K?
Y/N
E01
1
REAR ELEVATION
1.62
I
12
210
LED
12
524
Y
1
E02
1
FRONT ELEVATION
31.17
I
12
210
LAMP
32
816
Y
1
F1 For Allotted LPD use 12 watts/square foot for Internally Illuminated Signs, and use 2.3 watt /ft2 for Externally Illuminated Signs.
Note: If an Internally Illuminated or Externally Illuminated sign contains light sources and ballasts other than those included in columns (M) through (S), such
as incandescent lamps, medium base sockets, magnetic ballasts, etc, then the sign must comply under Alternative 1. However, unfiltered signs, and
unfiltered portions of Internally and Externally illumi nated signs, are not required to meet these Standards.
.2005 Nonresidential Compliance Forms
April 2005