HomeMy WebLinkAboutPA2020-052_20210826_Parking PlanELECTRICAL
ROOM
STAIR 3
STAIR 4
NEW
ELEVATOR
WOMEN
RESTROOM MEN RESTROOM
SOUTH ENTRY
LOBBY 1
NORTH ENTRY
SOUTH ENTRY
LOBBY 2
STAIR 2
STAIR 1
ELECTRICAL
ROOM
BREAK
ROOM
MANAGEMENT
OFFICE
JAN
CANOPY C2CANOPY C3CANOPY C1ELECTRICAL
ROOMRESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED
STAIR 5VALETDROPOFFPICKUPVALETDROPOFFPICKUPVALETDROPOFFPICKUPVALETDROPOFFPICKUPVALETDROPOFFPICKUPVALETDROPPICKUPOFFVALETDROPOFFPICKUPRESERVED18'-0"13'-1"18'-0"2'-6"2'-6"2'-6"18'-0"13'-0"18'-0"2'-6"B R I S T O L S T N S P R U C E A V E 7
4
8
1621
19
44
7
7
34 17'-0"26'-10"17'-0"17'-0"26'-0"17'-0"DRIVEWAY
32'-0"26'-0"17'-0"17'-0"26'-0"17'-0"17'-0"18'-0"26'-0"VIEW #3VIEW #2VIEW #12'-6"2'-6"
6
45°45°TYP.
8'-6"TYP.8'-6"TYP.8'-6"17'-0"26'-0"TYP.8'-6"2'-6"2'-6"9'-0"5'-0"9'-0"5'-0"9'-0"9'-0"5'-0"9'-0"9'-0"5'-0"12'-0"5
4
4
TYP
TYP
4
TYP
3
3
7
8
9
2
1 DRIVEWAY26'-4"3
1 4 0 0 B R I S T O L S T N1 4 2 0 B R I S T O L S T N2'-6"2'-6"2'-6"TYP
8'-6"
TYP.
8'-6"8'-6"8'-6"8
3
11
12
10
10
17
3'-0"10
10
11
11
12
17'-2"17'-2"17'-2"17'-2"17'-2"17'-2"17'-2"17'-2"
A9-02
3 VIEW #418
A9-02
4
17'-0"26'-2"8'-7"17'-0"KEYNOTE
1 (N) OVERHANG CANOPY STRUCTURE WITH SOLAR PANEL ROOFING
2 (N) 2-CAR CAPACITY PARKING CAR LIFT SYSTEM.
3 DASH LINE INDICATES PORTION OF EXISTING CURB AND PLANTER TO BE MODIFIED
4 (N) LANDSCAPE AND HARDSCAPE
5 (N) 8' HIGH GREEN SCREEN
6 VALET ATTENDANT COVERED SEATING AND PROCESSING AREA
7 (N) 48" WIDE TRUNCATED DOME PAVERS
8 RESTRIPE TO 45 DEG PARKING (FROM 60 DEG.)
9 REMOVE (E) BOLLARD, TYP.
10 SITE SIGNAGE TO READ - TO ALL DESIGNATED TENANTS: PARK IN "VALET DROP-OFF AREA" DURING
BUSINESS HOURS BETWEEN 7:00 AM TO 6:00 PM AND WAIT FOR VALET ATTENDANT
11 SITE SIGNAGE TO READ - "VALET DROP-OFF AREA" - PLEASE PARK CAR HERE AND WAIT FOR VALET
ATTENDANT TO TAKE YOUR KEYS AND PARK YOUR CAR.
12 THE WORD "VALET DROP-OFF" TO BE PAINTED AT THIS STALL
13 (N) METAL CLAD WALL AND SOFFIT
14 (N) STEEL FRAMED CANOPY
15 (N) STEEL FRAMED TRELLIS
16 (N) MONUMENT SIGNAGE (BY OTHERS, SEPARATE SUBMITTAL)
17 (E) TRASH ENCLOSURE
18 (N) HYDRAULIC POWER SYSTEM
PROPERTY LINE
ACCESSIBLE ROUTE PER CBC 1110A.1
AN ACCESSIBLE ROUTE SHALL BE PROVIDED
TO ALL PORTION OF THE BUILDING REQUIRED
TO BE ACCESSIBLE, ACCESSIBLE BUILDING
ENTRANCES AND BETWEEN THE BUILDING AND
THE PUBLIC WAY.
THE ACCESSIBLE ROUTE SHALL BE THE MOST
DIRECT ROUTE AND TO MAXIMUM EXTEND
FEASIBLE, COINCIDE WITH THE ROUTE FOR THE
GENERAL PUBLIC AND BUILDING RESIDENTS.
SEE CIVIL DWG FOR ADDITIONAL INFORMATION.
LEGEND
30 Corporate Park
Suite 201
Irvine, CA 92606
www.vdbg.com
949.679.6300
Varisco Designs, Inc.
8/2/2021 10:51:01 AM
A9-00
PARKING PLAN
21-007
NEWPORT BEACH, CA
1400-1420 BRISTOL
07/09/2021
1400 & 1420 N BRISTOL ST
949-721-1414
NEWPORT BEACH
CA 92660
1/16" = 1'-0"1 PARKING PLAN PHASE 1
PROVIDED PARKING
ACCESSIBLE 5 3%
ACCESSIBLE VAN 1 1%
PARKPLUS W02 34 20%
STANDARD 8'-6" x 17' 102 61%
STANDARD 8'-6" x 18' - 45 deg 24 14%
STANDARD 9' x 18' 1 1%
167NESW
30 Corporate Park
Suite 201
Irvine, CA 92606
www.vdbg.com
949.679.6300
Varisco Designs, Inc.
8/2/2021 10:21:40 AM
A9-01
PERSPECTIVE VIEWS
21-007
NEWPORT BEACH, CA
1400-1420 BRISTOL
07/09/2021
1400 & 1420 N BRISTOL ST
949-721-1414
NEWPORT BEACH
CA 92660
1
2 4
3
15'-0" CLEAR7'-0" CLEAR1
2
3
4
18'-6"18'-6"
VALET DROP-OFF
AND
PICK UP AREA
TO ALL DESIGNATED
TENANTS: PARK IN "VALET
DROP-OFF AREA" DURING
BUSINESS HOURS
BETWEEN 7:00 AM TO 6:00
PM AND WAIT FOR VALET
ATTENDANT
80" TO GROUNDVALET DROP-OFF
AND
PICKUP AREA
80" TO GROUND10REFER TO KEYNOTE
ON SHEET A900
11REFER TO KEYNOTE
ON SHEET A900
PLEASE PARK CAR HERE
AND WAIT FOR VALET
ATTENDANT TO TAKE
YOUR KEYS AND PARK
YOUR CAR.
2
A9-02
9'-5"4'-7"1'-10"2'-0"17'-2"17'-2"34'-4"17'-2"17'-2"17'-2"17'-2"6'-8"
3
1 2
46
146'-0"
1
5
4
6
18'-6"18'-6"9'-5"4'-7"1'-10"17'-10"KEYNOTE
1 SOLAR PANEL CANOPY STRUCTURE "RBI SOLAR #CP-TEE"
2 PERFORATED METAL PANEL "BOK MODERN #A04" FASTEN TO STEEL ANGLE FRAMING
3 48X96 GREEN SCREEN PANELS
4 PARKING CAR LIFT "PARKPLUS #DP003"
5 PAINTED WOOD SIDING FASTEN TO STEEL ANGLE FRAMING
6 HYDRAULIC POWER SYSTEM FOR CAR LIFT
30 Corporate Park
Suite 201
Irvine, CA 92606
www.vdbg.com
949.679.6300
Varisco Designs, Inc.
8/2/2021 10:21:45 AM
A9-02
PARKING DETAILS
21-007
NEWPORT BEACH, CA
1400-1420 BRISTOL
07/09/2021
1400 & 1420 N BRISTOL ST
949-721-1414
NEWPORT BEACH
CA 92660
1/4" = 1'-0"2 SECTION AT CAR LIFT
6" = 1'-0"1 SIGNAGE VALET DIRECTIONAL
1/4" = 1'-0"3 PARKING CANOPY FRONT ELEVATION
1/4" = 1'-0"4 PARKING CANOPY SIDE ELEVATION
BEYOND
• In-house Design, Manufacturing, Installation & Service
• Minimal Moving Parts – Reduced Maintenance
• Galvanized, commercial-Grade Machines
• Premium Quality Hydraulic cylinders
1 craDle FraMe aSSeMblY
2 HYDraulIc cYlINDer
3 Parallel arM aSSeMblY
4 aDJuStable HeIGHt aSSeMblY
5 SaFetY lockS aSSeMblY
6 eND leG aSSeMblY
7 SeISMIc beaM aSSeMblY
8 PlatForM aSSeMblY
9 PuSH buttoN coNtrolS
components layout
ParkPLuS DP003 Double Stacker can be arranged
in single or tandem arrays on either side of a drive
aisle. Queuing space of at least 2 vehicles must be
provided to allow for shuffling of cars. Queuing space
may be in drive aisle. For commercial projects, dur-
ing peak traffic, all platforms will be lowered for quick
filling of stackers. Surface space to be provided for
code-required accessible Parking.
The ParkPLuS DP003 Double Stacker is a hydraulic 2-post,
2-level cantilevered vehicle lift for parking cars one above
another. The DP003 raises and locks a platform in place so that a
second vehicle can be parked at grade.
Entire assembly comes pre-welded and is assembled in the field.
Stackers may be installed as single units or in arrays with shared
common legs. Stacker is designed to be mounted on grade,
concrete or asphalt. approved foundation system may be required
for installation of stackers.
The ParkPLuS DP003 Double Stacker is designed to be installed
indoors and outdoors. Platform height is field adjustable in 1 1/2"
increments. Each city may have minimum height requirements
and different clear requirements for code required parking.
owner/architect should review with local planning and building
departments. MeP coordination with project team must meet
code requirements and satisfy equipment clearances.
Suitable for
• Standard passenger vehicles
• SuVs
Specifications
load per Platform: 6,000 lbs.
Weight of unit: +/- 3,050 lbs.
length of Platform: 13'-6"
length incl. overhang: 16'-6"
Width of unit: 7'-11" to 9'-0"
Height of unit: 9'-6" to 9'-10"
operation: Hydraulic
control: Push button Pendant
*Custom Height and Width Available
Power Pack
Hydraulic Power System (HPS)
HPS1: 1-2 units
(208-230V / 1 PH / 60 HZ / 2-3 HP / 18 FLa)
HPS-1P10: 1-30 units
(208-230V / 1 PH / 60 HZ / 10 HP / 40 FLa)
HPS-3P10: 1-30 units
(208-230V / 3 PH / 60 HZ / 10 HP / 28.4 FLa)
electrical
1 Disconnect required per HPS
3 PH 208-230V / 40amp
1 PH 208-230V / 60amp
All control wiring is a Class 2 Circuit 24V
applications
DP003 Double Stacker can be installed in attended/valet and
self-park applications:
• Single & Multi-Family residential buildings
• Indoor & outdoor Installations
• low & High rise buildings
• commercial buildings
• Surface lots
WIDTH = Center of Leg to Center of Leg
Width
MoDel WIDtH
W01 7'-11"
W02 8'-3"
W03 8'-6"
W04 9'-0"
W05 Custom
MoDel HeIGHt
C/C 10'-6"
C/S 12'-2"
S/S 14'-0"
S/S* 14'-6"
clearance
S = Standard/SUVC = Compact/Sedan
*LA City requirement
ELECTRICAL
ROOM
STAIR 3
STAIR 4
NEW
ELEVATOR
WOMEN
RESTROOM MEN RESTROOM
SOUTH ENTRY
LOBBY 1
NORTH ENTRY
SOUTH ENTRY
LOBBY 2
STAIR 2
STAIR 1
ELECTRICAL
ROOM
BREAK
ROOM
MANAGEMENT
OFFICE
JAN
CANOPY C2CANOPY C3CANOPY C1ELECTRICAL
ROOMRESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVEDRESERVEDRESERVEDRESERVEDRESERVEDRESERVEDRESERVEDRESERVEDRESERVEDRESERVEDRESERVEDRESERVEDRESERVEDRESERVEDRESERVEDRESERVEDRESERVEDRESERVEDRESERVEDRESERVEDRESERVEDSTAIR 5VALETDROPOFFPICKUPRESERVEDVALET
DROP
OFF
PICKUP
VALET
DROP
OFF
PICKUP
VALET
DROP
OFF
PICKUP
VALET
DROP
OFF
PICKUP
VALET
DROP
OFF
PICKUP
VALET
DROP
OFF
PICKUP
RESERVED18'-0"13'-1"18'-0"2'-6"2'-6"2'-6"18'-0"13'-0"18'-0"2'-6"B R I S T O L S T N S P R U C E A V E 7
4
13
3221
19
44
7
7
34 17'-0"26'-10"17'-0"17'-0"26'-0"17'-0"DRIVEWAY
32'-0"26'-0"17'-0"17'-0"26'-0"17'-0"17'-0"
18'-0"
26'-0"2'-6"2'-6"45°TYP.
8'-6"TYP.8'-6"TYP.8'-6"17'-0"26'-0"TYP.8'-6"2'-6"2'-6"9'-0"5'-0"9'-0"5'-0"9'-0"9'-0"5'-0"9'-0"9'-0"5'-0"12'-0"5
4
4
TYP
TYP
4
TYP
7
2
9
2 1 DRIVEWAY26'-4"1 4 0 0 B R I S T O L S T N1 4 2 0 B R I S T O L S T N2'-6"2'-6"2'-6"TYP
8'-6"
TYP.
8'-6"8'-6"11
12
10
10
2 1
1
6
10
10
11
12
KEYNOTE
1 (N) OVERHANG CANOPY STRUCTURE WITH SOLAR PANEL ROOFING
2 (N) 2-CAR CAPACITY PARKING CAR LIFT SYSTEM.
3 DASH LINE INDICATES PORTION OF EXISTING CURB AND PLANTER TO BE MODIFIED
4 (N) LANDSCAPE AND HARDSCAPE
5 (N) 8' HIGH GREEN SCREEN
6 VALET ATTENDANT COVERED SEATING AND PROCESSING AREA
7 (N) 48" WIDE TRUNCATED DOME PAVERS
8 RESTRIPE TO 45 DEG PARKING (FROM 60 DEG.)
9 REMOVE (E) BOLLARD, TYP.
10 SITE SIGNAGE TO READ - TO ALL DESIGNATED TENANTS: PARK IN "VALET DROP-OFF AREA" DURING
BUSINESS HOURS BETWEEN 7:00 AM TO 6:00 PM AND WAIT FOR VALET ATTENDANT
11 SITE SIGNAGE TO READ - "VALET DROP-OFF AREA" - PLEASE PARK CAR HERE AND WAIT FOR VALET
ATTENDANT TO TAKE YOUR KEYS AND PARK YOUR CAR.
12 THE WORD "VALET DROP-OFF" TO BE PAINTED AT THIS STALL
13 (N) METAL CLAD WALL AND SOFFIT
14 (N) STEEL FRAMED CANOPY
15 (N) STEEL FRAMED TRELLIS
16 (N) MONUMENT SIGNAGE (BY OTHERS, SEPARATE SUBMITTAL)
17 (E) TRASH ENCLOSURE
18 (N) HYDRAULIC POWER SYSTEM
30 Corporate Park
Suite 201
Irvine, CA 92606
www.vdbg.com
949.679.6300
Varisco Designs, Inc.
8/12/2021 10:34:04 AM
A9-03
PARKING
MANAGEMENT PLAN
21-007
NEWPORT BEACH, CA
1400-1420 BRISTOL
08/12/2021
1400 & 1420 N BRISTOL ST
949-721-1414
NEWPORT BEACH
CA 92660
1/16" = 1'-0"1 PARKING MANAGEMENT PLAN
PROVIDED PARKING IN PHASE 2
ACCESSIBLE 5
ACCESSIBLE VAN 1
PARKPLUS W02 76
STANDARD 8'-6" x 17' 102
STANDARD 8'-6" x 18' - 45 deg 3
STANDARD 9' x 18' 1
188NESW