Loading...
HomeMy WebLinkAboutPA2021-308_20211222_Soils Report_8-17-21August 17, 2021 Mr. Jack Langson Project No: 72572-00 c/o PMR Construction, Inc. Report No: 21-8975 2061 Fairweather Road Santa Ana, California 92705 Attention: Mr. Chris Miller Subject: Preliminary Geotechnical Investigation Proposed New Single-Family Residence 2676 Bayshore Drive Newport Beach, California INTRODUCTION This report presents findings and conclusions of a preliminary geotechnical investigation undertaken to relate onsite and certain regional geotechnical conditions to the construction of a new single-family residence on the subject property. Analyses for this investigation are based upon the conceptual architectural plans for the property prepared by Skurman Architects. The conclusions and recommendations of this report are considered preliminary as they precede the development of finalized structural plans, the formulation of which are partially dependent upon the recommendations presented herein. Scope of Investigation The investigation included the following: 1.Analysis of pertinent reports, maps, aerial photographs, and published literature pertaining to the site and nearby areas, as well as project plans, in order to relate geotechnical conditions to proposed construction. 2.Field reconnaissance and logging of three limited-access cone penetration tests to evaluate the character and geometrical distribution of soil materials within the proposed construction area. 3.Laboratory testing was performed on this and adjacent sites to evaluate maximum density/optimum moisture content, grain size, direct shear strength, soluble sulfate and corrosivity. 4.Analyses of data and the preparation of this geotechnical report presenting conclusions and recommendations for site development in accordance with the 2019 California PA2021-308 August 17, 2021 Project No: 72572-00 Report No: 21-8975 Page No: 2 Building Code and the City of Newport Beach Building Code Policy CBC 1803.5.11-12. This report is suitable for use by your design professionals, contractors, and submittal to the City of Newport Beach. Accompanying Illustrations and Appendices Figure 1 - USGS Geologic Location Map Figure 2 - CDMG Geologic Hazards Location Map Figure 3 - Typical Retaining Wall Subdrain Detail Figure 4 - Geotechnical Plot Plan Appendix A - References Appendix B - CPT and Boring Logs Appendix C - Current and Previous Field Exploration and Laboratory Test Results Appendix D - Liquefaction Analysis Appendix E - Standard Grading Specifications Appendix F - Utility Trench Backfill Guidelines Site Description The roughly trapezoidal-shaped property fronts approximately 80± feet along Bayshore Drive and extends southwesterly up to 245± feet, which is 45± feet beyond the rear bulkhead. A topographic survey provided by Civilscapes Engineering, indicates the relatively flat building pad is at an average elevation of 13± feet (NAVD 88). The site is currently developed with a circa-1985 wood-frame, two-story single-family residence. The adjacent properties to the east and west are developed with similar single-family homes. Proposed Development Based on a review of conceptual plans prepared by Skurman Architects, proposed site improvements generally include the demolition and removal of the existing development to allow the construction of a new two-story single-family residence at or near existing site grades. Proposed exterior improvements include the construction of a new landscaping and hardscaping and replacement of portions of the existing bulkhead. The new residence is anticipated to be supported on a shallow stiffened foundation system designed in accordance with the Newport Beach Building Code Policy CBC 1803.5.11-12. Exterior elements are anticipated to be supported on conventional foundations and slabs on grade constructed in new engineered fill. GEOTECHNICAL CONDITIONS Geologic Setting The property is located on Harbor Island adjacent to Newport Bay as depicted on the USGS Geologic Index Map, Figure 1. It is located 0.60± miles northerly of the Pacific shoreline, approximately 1.9± miles easterly of the Newport pier and is 0.41± miles southwesterly of a former sea bluff on the inland side of Bayside Drive. Review of old topographic maps indicates PA2021-308 August 17, 2021 Project No: 72572-00 Report No: 21-8975 Page No: 3 that prior to dredging of Newport Bay, the site location was a low lying, likely intertidal area adjacent to a shallow channel of the natural bay. The site is underlain at a depth in excess of 50 feet by an accumulation of bay and beach deposits and subsequent dredge fill placed during land reclamation. A younger generation of fill from construction of the existing roads and residence may underlie the property at the surface. Earth Materials Based on the results of our CPT study, Dredge Fill underlies the site at the surface to an interpreted depth of 8± feet and generally consist of sand and silty sand. Up to 3± feet of silty and clayey fill soils were encountered in the rear yard and may have been locally placed to elevate the pad during original grading. Bay deposits underlie the dredge fill and is capped with a 1± foot thick layer of bay mud at an elevation roughly equivalent to mean sea level. Below this depth, silty sand and sand were encountered to a maximum explored depth of 46± feet. Cone penetrometer test data reveal that the earth materials underlying the site are variably dense within the upper 24± feet, becoming very dense below. Recompacted dredge fill is considered suitable for the support of new foundations. With the exception of the locally placed fine-grained fill in the rear yard, onsite materials are generally non-expansive on the basis of visual classification; laboratory testing of the similar soils on nearby sites indicates negligible soluble sulfate concentrations. Groundwater Groundwater was inferred at a depth of 5± feet below grade during our field exploration. Groundwater depth should be expected to fluctuate in response to tidal shifts. Groundwater is not considered to be a geotechnical constraint affecting the design and construction of proposed at-grade improvements. Street Flooding and Surface Drainage Localized street flooding associated with heavy rains and high tides has been a recurrent phenomenon in some low-lying areas of Newport Beach. The potential for flooding affecting proposed development should be evaluated by the project civil engineer. The proposed development may modify surface drainage, which should be evaluated and improved as necessary by the architect or civil engineer. Seismic Considerations Published Studies One of the principals of seismic analyses and prediction is the premise that earthquakes are more likely to occur on geologically younger faults, and less likely to occur on older faults. For many years studies have described faults with Holocene movement (within the last 11,000 years) as “Active”, and faults with documented Pleistocene movement (within the last 1.6 million years) PA2021-308 August 17, 2021 Project No: 72572-00 Report No: 21-8975 Page No: 4 and with undetermined Holocene movement as “Potentially Active”. Informally, many studies have described faults documented to have no Holocene movement as “Inactive”. Recent geologic and seismic publications are attempting to clarify the nomenclature describing faults to more accurately represent the potential affects from earthquakes. Reports by the California Division of Mines and Geology indicate faults with documented Holocene or Historic (within the last 200 years) movement should be considered Active. However, Potentially Active faults are more appropriately characterized in terms of the last period of documented movement. The Fault Activity Map of California (Jennings, C.W.; 2010) defines four categories for onshore Potentially Active faults. The categories are associated with the time of the last displacement evidenced on a given fault and are summarized in Table 1. Table 1, Definitions of Fault Activity in California It is important to note these categories embrace all Pre-Holocene faults as Potentially Active, and provide no methodology to designate a given fault as “Inactive”. Although the likelihood of an earthquake or movement to occur on a given fault significantly decreases with inactivity over geologic time, the potential for such events to occur on any fault cannot be eliminated within the current level of understanding. Local and Regional Faults The closest published active fault to the site is the offshore extension of the Newport-Inglewood Fault Zone, approximately 1.2 miles southwest, (Blake, T.F., 2000, CGS/2004). Other active faults in the vicinity of the site include the San Joaquin Hills, approximately 7.5 miles away, the Palos Verdes Fault, approximately 14.2 miles to the west; the Coronado Bank Fault, approximately 46.0 miles southwest; the Elsinore Fault, approximately 26.3 miles to the east, and the San Andreas Fault, approximately 62.0 miles to the northeast. The California Geological Survey updated the Fault Parameters and Earthquake Catalog for the probabilistic Seismic Hazards Maps in 2002. This update included the addition of the San Joaquin Hills blind thrust fault indicated above, theorized to exist from Newport Beach to Dana Point, and ramping up inland to the Irvine area, and essentially underlying the site. Earthquakes of Magnitude 6.6 are presently postulated for this structure. With the fault’s location at approximately 7.5 miles distant, it is calculated as the most significant seismic source to affect the site. Activity Category Recency of Movement Active Historic Within the last 200 years Holocene Within the last 11,000 years Potentially Active Late Quaternary Within the last 700,000 years Quaternary Within the last 1.6 million years Pre-Quaternary Before the last 1.6 million years PA2021-308 August 17, 2021 Project No: 72572-00 Report No: 21-8975 Page No: 5 Historic Ground Motion Analyses Utilizing attenuation relationships (Bozorgnia, et al.; 1999, unconstrained/Holocene sediments), one can estimate the ground motion history of the site. The study indicates the maximum site acceleration from 1800 to 2004 was approximately 0.5g and occurred during the magnitude 6.3 Long Beach Earthquake 2.8 miles from the site on March 11, 1933. It is noted that the estimation of historic peak ground acceleration presented above is provided for the interest of the client and is required by local (City or County) review agencies. The value derived is not directly utilized in structural design of residential structures. Seismic parameters for use by the structural engineer in accordance with 2019 California Building Code in design of the proposed structure(s) are presented in the recommendations portion of this report. Site Classification for Seismic Design Review of the Seismic Hazards Zones Map (California Division of Mines and Geology, 1998) for the Newport Beach Quadrangle, Figure 2, indicates this lot is not located within a “zone of required investigation” for earthquake induced landslides, but is located in a liquefaction hazard zone. Please refer to the Appraisal of Liquefaction Potential above for more information. For the purposes of determining seismic design parameters provided in the Recommendations portion of this report pertaining to the new structures, the upper one hundred feet of soil underlying the subject site has been classified in accordance with Section 1613.2.2 of the 2019 CBC and Section 20.1 of ASCE 7-16. Although the soils underlying the site are liquefiable and classify as F per the 2019 CBC, requiring a site-response analysis, proposed new structures are anticipated to have fundamental periods of vibration less than 0.5 seconds (to be verified by the structural engineer). As such, Section 20.3.1 in ASCE 7-16 provides an exception that indicates such liquefiable sites may be classified in accordance with Table 20.3-1 without performing an evaluation. Given the exception and the results of our onsite and nearby field investigations, which indicate the site is predominantly underlain by earth materials with average interpreted N-values between 15 and 50, seismic design criteria may be calculated using a site classification of D. However, the Site Class remains F. Appraisal of Liquefaction Potential Review of the Seismic Hazard Zones Map for the Newport Beach Quadrangle (California Division of Mines & Geology, 1998) identifies the site and all of the Newport/Balboa peninsula and harbor within a zone of required investigation for liquefaction. In accordance with City of Newport Beach Building Code Policies CBC-1803.5 and 1803.5.11-12 and the California Geological Survey SP117A (2008), our office has performed an analysis for liquefaction potential based on the CPT data collected during our onsite investigation. PA2021-308 August 17, 2021 Project No: 72572-00 Report No: 21-8975 Page No: 6 Based on the results of our analysis presented in Appendix D, which indicates liquefaction settlement within the upper 50 feet is less than  inches, a stiffened foundation system or mat slab designed in accordance with the City’s “Shallow Mitigation Methods” may be utilized as recommended herein. Please note that an evaluation of lateral spreading, which is typically integral to liquefaction analyses, is not considered necessary based on our review of the proposed bulkhead replacement plan prepared by PMA Consulting, Inc. Lateral spreading is not considered a geotechnical design constraint following construction of the new bulkhead. Secondary Seismic Hazards Other secondary seismic hazards can include deep rupture, shallow ground cracking, and tsunami inundation. With the absence of active faulting onsite, the potential for deep fault rupture is not present. The potential for shallow ground cracking to occur during an earthquake is a possibility at any site, but does not pose a significant hazard to site development. Regarding tsunami inundation, please refer to the appropriate section above for more information. CONCLUSIONS 1. The proposed development at the subject site is considered geotechnically feasible provided the recommendations herein are integrated into design, construction, and long- term maintenance of the property. Proposed construction should not affect or be affected by adjacent properties provided appropriate construction methods and care are implemented. 2. The property is underlain at a depth greater than 46± feet by bedrock strata of Monterey Formation, which are successively overlain by sandy bay deposits and 8± feet of dredge fill. 3. The removal and re-compaction of the upper 3± feet of existing soil for the entire site is recommended prior to construction of new foundations. 4. Granular onsite soils are non-expansive, are expected to have a negligible soil soluble sulfate level, and a very low potential for corrosion of buried metal based on prior adjacent laboratory testing. However, as placed concrete is in a marine environment, a moderate sulfate exposure may be used for design purposes. The concrete mix should be designed by a concrete expert in consideration of structural requirements. The appropriate exposure should be evaluated by the architect and/or structural engineer. 5. No active faults are known to transect the site and therefore the site is not expected to be adversely affected by surface rupturing. It will, however, be affected by ground motions from earthquakes during the design life of the residence. PA2021-308 August 17, 2021 Project No: 72572-00 Report No: 21-8975 Page No: 7 Liquefaction analysis performed in accordance with City Building Code Policies CBC-1803.5 and 1803.5.11-12 and SP117A (CGS, 2008) indicates seismic settlement withinthe upper 50 feet of subgrade soils is less the  inches. Therefore, a mat slab or stiffenedfoundation system designed in accordance with the City’s “Shallow Mitigation Methods”may be utilized as recommended herein. Groundwater was inferred at a depth of 5± feet below grade during our field exploration. Groundwater depth should be expected to fluctuate in response to tidal shifts. Groundwater is not considered to be a geotechnical constraint affecting the design and construction of proposed at-grade improvements. The potential of street flooding affecting the residence during its lifetime is deferred to the project civil engineer. Surface discharge onto or off the site should be appropriately controlled with proper engineering design and site grading. The proposed residence may be supported on a stiffened shallow foundation designed in accordance with the Newport Beach Building Code Policy CBC 1803.5.11-12. RECOMMENDATIONS Site Preparation and Grading 1. General Grading should be performed in accordance with the recommendations herein and the Standard Grading Specifications in Appendix E. Grading is anticipated to consist of remedial over-excavation and minor cut/fills to construct the proposed building pad and foundation subgrades. Processing, over-excavation and re-compaction should be observed, tested and approved in writing by a representative of this firm. 2. Remedial Grading Remedial grading is recommended to include removal and re-compaction of existing near-surface soils three feet below existing site grades. Locally deeper removals may be required pending field review by the geologist. Finer grained, potentially expansive soils encountered in the rear yard are recommended to be relocated as necessary to future landscape areas pending field review by the geologist or field technician during grading. PA2021-308 August 17, 2021 Project No: 72572-00 Report No: 21-8975 Page No: 8 3. Removal of Existing Improvements Existing vegetation, organic materials and/or construction and demolition debris should be removed and disposed of offsite. 4. Compaction Standard Onsite soil materials are anticipated to be suitable for re-use as compacted fill providing they are free of rubble and debris. Materials should be placed at 120 percent of optimum moisture content and compacted under the observation and testing of the soil engineer to at least 90 percent of the maximum dry density as evaluated by ASTM D 1557. 5. Temporary Construction Slopes Although not anticipated, significant temporary slopes exceeding 3 feet should be cut in accordance with Cal/OSHA Regulations. It is anticipated that the onsite soils may be classified as Type C soil, and temporary cuts with a sloping ratio of 1.5:1 (horizontal: vertical) may be appropriate; however, the material exposed in temporary excavations should be evaluated by the contractor during construction. The safety of temporary construction slopes is deferred to the general contractor, who should implement the safety practices as defined in Section 1541, Subchapter 4, of Cal/OSHA T8 Regulations (2006). Shoring should be anticipated where space limitations preclude temporary slope layback, in any location where onsite personnel may be in close proximity to open excavations greater than 5 feet in total height. Shoring also should be anticipated where wet materials are exposed. Foundation Design Parameters Due to the potential for liquefaction at the site, we recommend that a stiffened foundation or mat slab be used for the proposed structure in accordance with the City of Newport Beach Building Code Policy No. CBC-1803.5.11-12. Such a foundation system should be founded on properly compacted fill derived from onsite materials. 1. Bearing Capacity and Settlement The allowable bearing capacity for a stiffened foundation or mat slab placed on approved recompacted fill with a thickness of 12 inches or more is 2,000 pounds per square foot. Foundation settlement from structural loading is estimated to be ¾ inch total and ½ inch differential over a distance of 30 feet. The majority of the static foundation settlement should occur during construction. Total and differential settlements during the probable design earthquake are estimated at ¾-inch and 1/2 inch, respectively. Total and differential PA2021-308 August 17, 2021 Project No: 72572-00 Report No: 21-8975 Page No: 9 settlements during the maximum considered earthquake are estimated at 1.5 and 1 inch, respectively. 2. Lateral Loads Lateral loads may be resisted by passive pressure forces and friction acting on the bottom of foundations. Passive pressure may be computed from an equivalent fluid density of 150 pounds per cubic foot above the groundwater table, not to exceed 2,000 pounds per square foot. A coefficient of friction of 0.25 may be used in computing the frictional resistance. These values may be combined without reduction. 3. Reinforcement Foundations and slabs should be reinforced in conformance with the requirements of the structural engineer. From a geotechnical viewpoint, a minimum of two No. 5 bars should be incorporated at the top and bottom of continuous footings in order to reduce the potential for cracking during seismic shaking or as a result of subsurface imperfections. Monitoring Complete documentation of the pre- and post-construction conditions of adjacent improvements should be undertaken. In addition, monitoring of ground movement and construction vibrations should be made as an integral part of the construction. Such documentation should include: 1. A sufficient number of photographs to establish the existing condition of nearby structures. 2. Establishment of a sufficient number of ground elevation control stations so that potential subsidence or heave associated with grading and lateral movement can be detected. Monitoring of such points should be accomplished during all grading, shoring (if any), and excavation work. 3. Ground vibration monitoring during construction to capture peak particle velocities of drilling, tracking, and excavation activities is recommended. Vibration monitors should be Sigicom model C-22 tri-axial geophones or equal. Hardscape Design and Construction Hardscape improvements may utilize conventional foundations embedded in recompacted fill designed in accordance with the foundation recommendations presented above. Foundations should have a design depth of 18 inches or more. Concrete flatwork should be divided into as nearly square panels as possible. Joints should be provided at maximum 6 feet intervals to give articulation to the concrete panels. Landscaping and planters adjacent to concrete flatwork should be designed in such a manner as to direct drainage away from concrete areas to approved outlets. Planters located adjacent to principal foundation elements should be sealed and drained. PA2021-308 August 17, 2021 Project No: 72572-00 Report No: 21-8975 Page No: 10 Flatwork elements should be a minimum 5 inches thick (actual) and reinforced with No. 4 bars 16 inches on center both ways. Seismic Design Based on the geotechnical data and site parameters, the following is provided by the USGS (ASCE 7-16) to satisfy the 2019 CBC design criteria: Table 2, Site and Seismic Design Criteria for the 2019 CBC Design Parameters Recommended Values Site Class Site Longitude (degrees) Site Latitude (degrees) SS (g) B S1 (g) B SMS (g) D1 SM1 (g) D1 SDS (g) D1 SD1 (g) D1 Fa Fv Seismic Design Category PGAM(g) F -117.9086 33.6125 1.384 0.492 1.384 0.891 0.923 0.594 1.00 1.81 D 0.666 1This evaluation assumes the fundamental period of vibration of proposed structures does not exceed 0.5 second. Finished Grade and Surface Drainage Finished grades should be designed and constructed so that no water ponds in the vicinity of footings. Drainage design in accordance with the 2019 California Building Code, Section 1804.4 is recommended. Roofs should be guttered and discharge conducted away from the house in a non-erosive manner as specified by the project civil engineer or landscape architect. Proper interception and disposal of all onsite surface discharge is presumed to be a matter of civil engineering or landscape architectural design. PA2021-308 August 17, 2021 Project No: 72572-00 Report No: 21-8975 Page No: 11 Concrete Soil soluble sulfate testing indicates negligible sulfate content. Onsite concrete may be exposed to seawater. It is recommended that a concrete expert be retained to design an appropriate concrete mix to address the structural and exposure requirements. In lieu of retaining a concrete expert, it is recommended that the 2019 California Building Code, Section 1904.1 be utilized, which refers to ACI 318, Table 4.3.1, and 4.2.1. The appropriate exposure should be evaluated by the architect and/or structural engineer. Utility Trench Backfill Utility trench backfill should be placed in accordance with Appendix F, Utility Trench Backfill Guidelines. It is the owners and contractor's responsibility to inform subcontractors of these requirements and to notify Geofirm when backfill placement is to begin. Foundation Plan Review In order to help assure conformance with recommendations of this report and as a condition of the use of this report, the undersigned should review final foundation plans and specifications prior to submission of such to the building official for issuance of permits. Such review is to be performed only for the limited purpose of checking for conformance with the design concept and the information provided herein. This review shall not include review of the accuracy or completeness of details, such as quantities, dimensions, weights or gauges, fabrication processes, construction means or methods, coordination of the work with other trades or construction safety precautions, all of which are the sole responsibility of the Contractor. Geofirm’s review shall be conducted with reasonable promptness while allowing sufficient time in our judgment to permit adequate review. Review of a specific item shall not indicate that Geofirm has reviewed the entire system of which the item is a component. Geofirm shall not be responsible for any deviation from the Construction Documents not brought to our attention in writing by the Contractor. Geofirm shall not be required to review partial submissions or those for which submissions of correlated items have not been received. Jobsite Safety Neither the professional activities of Geofirm, nor the presence of Geofirm’s employees and subconsultants at a construction/project site, shall relieve the General Contractor of its obligations, duties and responsibilities including, but not limited to, construction means, methods, sequence, techniques or procedures necessary for performing, superintending and coordination the work in accordance with the contract documents and any health or safety precautions required by any regulatory agencies. Geofirm and its personnel have no authority to exercise any control over any construction contractor or its employees in connection with their work or any health or safety programs or procedures. The General Contractor shall be solely responsible for jobsite safety. PA2021-308 August 17, 2021 Project No: 72572-00 Report No: 21-8975 Page No: 12 Pre-Grade Meeting A pre-job conference should be held with representative of the owner, contractor, architect, civil engineer, soils engineer, engineering geologist, and building official prior to commencement of construction, to clarify any questions relating to the intent of these recommendations or additional recommendations. Observation and Testing The 2019 California Building Code, Section 1705.6 requires geotechnical observation and testing during construction to verify proper removal of unsuitable materials, that foundation excavations are clean and founded in competent material, to test for proper moisture content and proper degree of compaction of fill, to test and observe placement of wall and trench backfill materials, and to confirm design assumptions. It is noted that the CBC requires continuous verification and testing during placement of fill, pile driving, and pier/caisson drilling. A Geofirm representative shall visit the site at intervals appropriate to the stage of construction, as notified by the Contractor, in order to observe the progress and quality of the work completed by the Contractor. Such visits and observation are not intended to be an exhaustive check or a detailed inspection of the Contractor’s work but rather are to allow Geofirm, as an experienced professional, to become generally familiar with the work in progress and to determine, in general, if the work is proceeding in accordance with the recommendations of this report. Geofirm shall not supervise, direct, or have control over the Contractor’s work nor have any responsibility for the construction means, methods, techniques, sequences, or procedures selected by the Contractor nor the Contractor’s safety precautions or programs in connection with the work. These rights and responsibilities are solely those of the Contractor. Geofirm shall not be responsible for any acts or omission of the Contractor, subcontractor, any entity performing any portion of the work, or any agents or employees of any of them. Geofirm does not guarantee the performance of the Contractor and shall not be responsible for the Contractor’s failure to perform its work in accordance with the Contractor documents or any applicable law, codes, rules or regulations. These observations are beyond the scope of this investigation and budget and are conducted on a time and material basis. The responsibility for timely notification of the start of construction and ongoing geotechnically involved phases of construction is that of the owner and his contractor. Typically, at least 24 hours’ notice is required. PA2021-308 August 17, 2021 Project No: 72572-00 Report No: 21-8975 Page No: 13 LIMITATIONS This investigation has been conducted in accordance with generally accepted practice in the engineering geologic and soils engineering field. No further warranty is offered or implied. Conclusions and recommendations presented are based on subsurface conditions encountered and are not meant to imply a control of nature. As site geotechnical conditions may alter with time, the recommendations presented herein are considered valid for a time period of one year from the report date. The recommendations are also specific to the current proposed development. Changes in proposed land use or development may require supplemental investigation or recommendations. Also, independent use of this report in any form cannot be approved unless specific written verification of the applicability of the recommendations is obtained from this firm. Thank you for this opportunity to be of service. If you have any questions, please contact this office. Respectfully, GEOFIRM Erik R. Hilde, P.G., E.G. 2303 Russell C. Lamb, P.E. 38380, G.E. 2207 Associate Engineering Geologist Principal/ Chief Geotechnical Engineer Date Signed: 8 /17 / 2021 ERH/RCL:hsm Distribution: Addressee via email 2323232323232323232323232323233232323230303030303030303030303030303030303030303 ololololololololololollololollololollogogogogogogogogogogogogogogogogogogogoisisisisisisiisisisisisisisisisisisisstttttttttttt R ll C L b P E 38380 GEOFIRRRRRRRRRRRRRRRRRRRRRRRMMMMMMMMMMMMMMMMMMMMMMM E ik R Hild P G EEEEEEEEEEEEEEEEEEEEEE G 0,,,,,,,GGGGGGGGGGGGGGGGGGGGG.E.E.E.E.E.E.E.E.E.E.E.E.E.E.EE.E.EE.............222222222222222207 al EnEnEnEnEnEnEnEnEnEnEnEnEnEnEnEnEnEnEnEnngigigigigigigigigigigigigigigigigigigiggneneneneneneneneneneneneneneneneneneneneneerererererererererererererererererererer 1 0 GGGGGGGGGGGG PA2021-308 JOB NO.:DATE:FIGURE:USGS Geologic Location Map, Santa Ana 30' x 60' Quadrangle72572-00August 20211SITE2676 Bayshore DriveNewport BeachPA2021-308 JOB NO.:DATE:FIGURE:CDMG Geologic Hazards Location Map, Newport Beach Quadrangle72572-00August 20212SITE2676 Bayshore DriveNewport BeachPA2021-308 JOB NO.:DATE:FIGURE: Typical Retaining Wall Subdrain Detail 72572-00 August 2021 3 Onsite Native Soil Cap for exterior ; (1.5'-2.0' MAX. thick)Select Noncohesive Granular Backfill (SE >30) Retaining Wall Footing Geotextile Filter Fabric 4" Perforated Plastic Collector Pipe (Below Adjacent Finish Grade) Single-sized 1/2"- 3/4" Drain Rock (1 cubic foot per lineal foot) Limit of Wall Excavation - See Report for Recommended Geometery Typical Retaining Wall Notes:This system consists of a geotextile fabric-wrapped gravel envelope. Collection is with a 4-inch diameter perforated plastic pipe embedded in the gravel envelope and tied to a 4-inch diameter non-perforated plastic pipe which discharges at convenient locations. The outlet pipe should be placed such that the flow gradient is not less than 2.0 percent. The geotextile fabric- wrapped gravel envelope should be placed at a similar gradient All drain pipes should be Schedule 40 PVC or ABS SDR-35. Perforations may be either bored 1/4-inch diameter holes or 3/16-inch slots placed on the bottom one-third of the pipe perimeter. If the pipe is to be bored, a minimum of 10 holes should be uniformly placed per foot of length. If slots are made, they should not exceed 2-1/2 inches in length and should not be closer than 2 inches. Total length of slots should not be less than 50 percent of the pipe length and should be uniformly spaced. The fabric pore spaces should not exceed equivalent 30 mesh openings or be less than equivalent 100 mesh openings. The fabric should be placed such that a minimum lap of 8-inches exists at all splices. 12"-18" Finish Grade - Design May Vary per Architect or Civil Engineer Alternative Weep Hole(s) for Exterior Applications, Design per Architect or Civil Engineer PA2021-308 GEOTECHNICAL PLOT PLAN2676 BAYSHORE DRIVENEWPORT BEACH, CALIFORNIASCALE: 1"=20'72572-00 21-8975AUGUST 20214JOB NO.:REPORT NO.:DATE:FIGURE:CPT-3QdfDREDGE FILLBAY/BEACH DEPOSITSAPPROXIMATE CONE PENETROMETERTEST LOCATIONEXPLANATIONQbQdfQbCPT-2CPT-3CPT-1PA2021-308 APPENDIX A REFERENCES PA2021-308 APPENDIX A REFERENCES 1. Al Atik, Linda, M. ASCE, and Sitar, Nicholas, M.ASCE, 2010, Seismic Earth Pressures on Cantilever Retaining Structures, ASCE Journal of Geotechnical and Geoenvironmental Engineering, dated October. 2. Bozorgnia, Y., Campbell, K.W., and Niazi, M. M., 1999, “Vertical Ground Motion: Characteristics, Relationship with Horizontal Component, and Building Code Implications”, Proceedings of the SMIP99 Seminar on Utilization of Strong-Motion Data, pp. 23-49, dated September 15. 3. California Building Code, 2019 Edition. 4. California Division of Mines & Geology, 1998, “Seismic Hazards Zones Map, Newport Beach Quadrangle.” 5. California Geological Survey, 2008, “Guidelines for Evaluating and Mitigating Seismic Hazards in California,” Special Publication 117A. 6. Geofirm, 2007, “Geofirm, 2006, “Geotechnical Investigation for Foundation Design, Proposed Single Family Residence, 2741 Bayshore Drive, Newport Beach, California”; Project No: 71662- 00, Report No: 06-5867, dated August 31. 7. Geofirm, 2015, “Preliminary Geotechnical Investigation, Proposed New Single-Family Residence, 2742 & 2752 Bayshore Drive, Lots 4 & 5, Tract 1014, Newport Beach, California,” Project No. 72215-00, Report No. 15-7769, dated December 1. 8. Geofirm, 2020, “Preliminary Geotechnical Investigation, Proposed New Single-Family Residence, 115 & 119 Via Mentone, Newport Beach, California”, Project No. 72488-00, Report No. 20-8683. 9. Geofirm, 2021, “Preliminary Geotechnical Investigation, Proposed New Single-Family Residence, 434 Via Lido Nord, Newport Beach, California,” Project No. 72550-00, Report No. 21-8848, dated January 22. 10. Grant et al, 1999, “Late Quaternary Uplift and Earthquake Potential of the San Joaquin Hills, South Los Angeles Basin, California.” 11. Jennings, Charles W., et al, 1994, “Fault Activity Map of California and Adjacent Areas,” California Division of Mines and Geology, Geologic Data Map No. 6. 12. Legg, Mark R., et al, 2003, “Evaluation of Tsunami Risk to Southern California Coastal Cities,” Earthquake Engineering Research Institute. January 13. Morton, P.K., et al, 1973, “Geo-Environmental Maps of Orange County,” California Division of Mines and Geology, Preliminary Report 15. 14. United States Geological Survey, 2002, "Preliminary Digital Geologic Map of the Santa Ana 30' x 60' Quadrangle, southern California, Version 1.0". PA2021-308 APPENDIX B CPT LOGS PA2021-308                 ! "#$# !"!#$%                               !" # $                                                        %& ' "%&( )    * ))   ) + ) )  "## ,-.&)/   %0%&&)/  ! 01 )2 ) 3 "0%&+ ) 0&  PA2021-308                 ! "#$# !"!#$                               !" # $                             %& ' "%&( )    * ))   ) + ) )  "## ",-&).   %/%&&).  ! /0 )1 ) 2 "/%&+ ) /&  PA2021-308                   !"#" !"!#$%                               !" # $                 $% & !$%' (    ) ((   ( * ( (  !""+,%(-   $.$%%(-    ./ (0 ( 1 !.$%* ( .%  PA2021-308 2 1 2 1 3 4 4 6 8 4 7 10 16 27 37 20 30 32 15 20 21 8 11 14 16 16 12 6 7 15 TOPSOIL: Sandy SILT. Black, organic rich, moist, loose. SAND: Grey, moist, loose, fine grained. SAND: Brown, wet, loose, fine-medium grained. @7' Groundwater SAND: Brown, wet, loose, fine grained. SAND: Brown, wet, firm, fine grained. SAND: Brown, wet, loose-firm, fine grained. @14' No sample recovery @16' No sample recovery @18' No sample recovery Total Depth 21.5' Groundwater encountered 7' Backfilled with cuttings LOG OF BORING Depth (feet)Description USCSUndisturbedSampleBlows/6"MoistureContent (%)Depth (feet)In-place DryDensity (pcf)Project No.: 72215-00 Date(s) Logged: 10/22/2015 Drilling Company: Native Drilling Drop: 30-inch Weight(s): 140# Standard Logged By: TWK Figure No.: B-1 Address: Method of Drilling: 6-inch Hollow Stem Auger Geofirm 2752 Bayshore Drive;Newport Beach, CA BORING NO.: B-1 Geologic Attitude 0 5 10 15 20 25 30 35Bulk Sample0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 PA2021-308 6 5 7 5 5 4 3 7 7 16 20 23 TOPSOIL: Sandy SILT. Black, organic rich, moist, loose. SAND: Grey brown, moist, loose, fine grained. SAND: Black, moist, loose, fine-medium grained. SAND: Black, wet, loose, fine grained. SAND: Brown, wet, loose-firm, fine-medium grained. Total Depth 9.5' Groundwater encountered 8' Backfilled with cuttings LOG OF BORING Depth (feet)Description USCSUndisturbedSampleBlows/6"MoistureContent (%)Depth (feet)In-place DryDensity (pcf)Project No.: 72215-00 Date(s) Logged: 10/22/2015 Drilling Company: Native Drilling Drop: 30-inch Logged By: TWK Figure No.: B-2 Address: Method of Drilling: Hand Auger Geofirm 2752 Bayshore Drive;Newport Beach, CA BORING NO.: B-2 Geologic Attitude 0 5 10 15 20 25 30 35Bulk Sample0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 PA2021-308 APPENDIX C CURRENT AND PREVIOUS FIELD EXPLORATION AND LABORATORY TEST RESULTS (2752 Bayshore Drive, Reference 7, Appendix A) PA2021-308 APPENDIX C CURRENT AND PREVIOUS FIELD EXPLORATION AND LABORATORY TEST RESULTS (2752 Bayshore Drive, Reference 7, Appendix A) I. Field Exploration Procedures A. Onsite Field Exploration Our field services consisted of three CPT sounding to a maximum depth of 46 feet. Historic borings were made at 2752 Bayshore Drive and extended to depths of 9.5 and 21.5 feet below existing grade. Logs of our CPT and borings are included in Appendix B. B. Onsite Sampling A representative, near-surface bulk sample was bagged and transported to the laboratory for classification and physical testing. C. Sampling (2752 Bayshore Drive)\ 1. Standard Penetration Test Samples of subsurface materials were obtained by driving a steel barrel drive sampler with an effective weight of 140/40 pounds that is raised and permitted to fall 30 inches. The sampler has an outside diameter of 2.0 inches and an inside diameter of 1.375 inches. The samples were removed from the sample barrel for visual analysis in the field. Records of the number of blows required to effect each 6 inches of penetration were made. 2. Disaggregated Samples Bulk samples of typical soil types were bagged and transported to the laboratory for classification and physical testing. II. Laboratory Testing Procedures Corrosion Test Results (2752 Bayhore Drive) Sample Designation - Boring 1 @ 0-4’ pH - 6.9 Soluble Sulfate - 47 mg/kg Minimum Resistivity - 2,960 ohm-cm PA2021-308 C. Particle Size Analyses (2752 Bayshore Drive) Particle size analyses were performed on samples in accordance with ASTM D422. The results of the tests are presented graphically on Figure C-1. D. Direct Shear Test (2752 Bayshore Drive) A direct shear test was performed in general accordance with ASTM D 3080 on remolded soil specimens inundated before and during testing. The direct shear machine employed was a conventional single shear, strain-controlled device. The shearing strength parameters were obtained by fitting a straight line through three points of peak and ultimate shear strength versus total normal stress. The total normal stress range used was 1000 to 4000 pounds per square foot. Results from the test are summarized on Figure C-2. E. Maximum Density and Optimum Moisture Determinations (onsite) Optimum moisture and maximum density were determined in accordance with Test Designation ASTM D 1557. These results are tabulated below: Moisture Content Dry Density Sample Location (%) Optimum (pcf) Maximum TP-1 @ 0’ 14.4 113.4 PA2021-308                                      !"  #  $%&  ''''  &  '&%  # #  ('$)'' * "   ''+'%''% *,-./  *,-./ ' $  0-//*-1,   2 0-3201  2-!2.-40          !       (5".,  61          ! " #$%&  ' PA2021-308                                         ! "! !     ! %&' %&' ( (     "#$%&'() *2          ! " #$%&  ' PA2021-308 APPENDIX D LIQUEFACTION ANALYSIS PA2021-308 LIQUEFACTION ANALYSIS REPORT Input parameters and analysis data Analysis method:Fines correction method: Points to test:Earthquake magnitude Mw:Peak ground acceleration: NCEER (1998)NCEER (1998)Based on Ic value6.880.67 G.W.T. (in-situ):G.W.T. (earthq.):Average results interval:Ic cut-off value:Unit weight calculation: Project title : Location : GeoLogismiki Geotechnical Engineers Merarhias 56 http://www.geologismiki.gr CPT file : CPT-1 5.00 ft5.00 ft12.60Based on SBT Use fill:Fill height: Fill weight:Trans. detect. applied:Kσ applied: NoN/AN/AYesYes Clay like behaviorapplied:Limit depth applied:Limit depth:MSF method: Sands onlyYes46.47 ftMethod based Cone resistance qt (tsf)4002000Depth (ft)46 44 42 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 Cone resistance SBTn Plot Ic (Robertson 1990)4321 46 44 42 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 SBTn Plot CRR plot CRR & CSR 0.60.40.20 46 44 42 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 CRR plot During earthq. Qtn,cs 200180160140120100806040200Cyclic Stress Ratio* (CSR*)0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 Liquefaction No Liquefact ion Normalized friction ratio (%)0.1 1 10Normalized CPT penetration resistance1 10 100 1,000 Friction Ratio Rf (%)1086420 46 44 42 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 Friction Ratio Mw=71/2, sigma'=1 atm base curve Summary of liquefaction potential FS Plot Factor of safety 21.510.50 46 44 42 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 FS Plot During earthq. Zone A1: Cyclic liquefaction likely depending on size and duration of cyclic loading Zone A2: Cyclic liquefaction and strength loss likely depending on loading and ground geometry Zone B: Liquefaction and post-earthquake strength loss unlikely, check cyclic softening Zone C: Cyclic liquefaction and strength loss possible depending on soil plasticity, brittleness/sensitivity, strain to peak undrained strength and ground geometry CLiq v.3.3.1.14 - CPT Liquefaction Assessment Software - Report created on: 5/3/2021, 2:36:05 PM Project file: V:\72450-72999\72572 (Langson) 2676 Bayshore\CPT-Liquefaction\CLiq.clq 1 PA2021-308 This software is licensed to: Stoney-Miller Consultants, IncCPT name: CPT-1Cone resistanceqt (tsf)4002000Depth (ft)4644424038363432302826242220181614121086420Cone resistanceCPT basic interpretation plotsFriction RatioRf (%)1086420Depth (ft)4644424038363432302826242220181614121086420Friction RatioPore pressureu (psi)100-10Depth (ft)464442403836343230282624222018161412108642Pore pressureInsituSBT PlotIc(SBT)4321Depth (ft)464442403836343230282624222018161412108642SBT PlotSoil Behaviour TypeSBT (Robertson et al. 1986)1817161514131211109876543210Depth (ft)4644424038363432302826242220181614121086420Soil Behaviour TypeSensitive fine grainedSand & silty sandSand & silty sandSilty sand & sandy siltClay & silty claySand & silty sandSandSandSand & silty sandSandSand & silty sandSandSandSand & silty sandSandSand & silty sandSandCLiq v.3.3.1.14 - CPT Liquefaction Assessment Software - Report created on: 5/3/2021, 2:36:05 PM2Project file: V:\72450-72999\72572 (Langson) 2676 Bayshore\CPT-Liquefaction\CLiq.clqInput parameters and analysis dataAnalysis method:Fines correction method:Points to test:Earthquake magnitude Mw:Peak ground acceleration:Depth to water table (insitu):NCEER (1998)NCEER (1998)Based on Ic value6.880.675.00 ftDepth to water table (erthq.):Average results interval:Ic cut-off value:Unit weight calculation:Use fill:Fill height:5.00 ft12.60Based on SBTNoN/AFill weight:Transition detect. applied:Kσ applied:Clay like behavior applied:Limit depth applied:Limit depth:N/AYesYesSands onlyYes46.47 ftSBT legend1. Sensitive fine grained2. Organic material3. Clay to silty clay4. Clayey silt to siltyl5. Silty sand to sandy silt6. Clean sand to silty sand7. Gravely sand to sand8. Very stiff sand told9. Very stiff fine grainedPA2021-308 This software is licensed to: Stoney-Miller Consultants, IncCPT name: CPT-1Norm. cone resistanceQtn200150100500Depth (ft)4644424038363432302826242220181614121086420Norm. cone resistanceCPT basic interpretation plots (normalized)Norm. friction ratioFr (%)1086420Depth (ft)4644424038363432302826242220181614121086420Norm. friction ratioNom. pore pressure ratioBq10.80.60.40.20-0.2Depth (ft)4644424038363432302826242220181614121086420Nom. pore pressure ratioSBTn PlotIc (Robertson 1990)4321Depth (ft)4644424038363432302826242220181614121086420SBTn PlotNorm. Soil Behaviour TypeSBTn (Robertson 1990)1817161514131211109876543210Depth (ft)4644424038363432302826242220181614121086420Norm. Soil Behaviour TypeSensitive fine grainedSand & silty sandSilty sand & sandy siltClay & silty claySand & silty sandSandSand & silty sandSandSandSand & silty sandSandSand & silty sandSandSand & silty sandSandSandSandCLiq v.3.3.1.14 - CPT Liquefaction Assessment Software - Report created on: 5/3/2021, 2:36:05 PM3Project file: V:\72450-72999\72572 (Langson) 2676 Bayshore\CPT-Liquefaction\CLiq.clqSBTn legend1. Sensitive fine grained2. Organic material3. Clay to silty clay4. Clayey silt to siltyl5. Silty sand to sandy silt6. Clean sand to silty sand7. Gravely sand to sand8. Very stiff sand told9. Very stiff fine grainedInput parameters and analysis dataAnalysis method:Fines correction method:Points to test:Earthquake magnitude Mw:Peak ground acceleration:Depth to water table (insitu):NCEER (1998)NCEER (1998)Based on Ic value6.880.675.00 ftDepth to water table (erthq.):Average results interval:Ic cut-off value:Unit weight calculation:Use fill:Fill height:5.00 ft12.60Based on SBTNoN/AFill weight:Transition detect. applied:Kσ applied:Clay like behavior applied:Limit depth applied:Limit depth:N/AYesYesSands onlyYes46.47 ftPA2021-308 This software is licensed to: Stoney-Miller Consultants, IncCPT name: CPT-1Total cone resistanceqt (tsf)4003002001000Depth (ft)4644424038363432302826242220181614121086420Total cone resistanceLiquefaction analysis overall plots (intermediate results)SBTn IndexIc (Robertson 1990)4321Depth (ft)4644424038363432302826242220181614121086420SBTn IndexNorm. cone resistanceQtn200150100500Depth (ft)4644424038363432302826242220181614121086420Norm. cone resistanceGrain char. factorKc109876543210Depth (ft)4644424038363432302826242220181614121086420Grain char. factorCorrected norm. cone resistanceQtn,cs200150100500Depth (ft)4644424038363432302826242220181614121086420Corrected norm. cone resistanceCLiq v.3.3.1.14 - CPT Liquefaction Assessment Software - Report created on: 5/3/2021, 2:36:05 PM4Project file: V:\72450-72999\72572 (Langson) 2676 Bayshore\CPT-Liquefaction\CLiq.clqInput parameters and analysis dataAnalysis method:Fines correction method:Points to test:Earthquake magnitude Mw:Peak ground acceleration:Depth to water table (insitu):NCEER (1998)NCEER (1998)Based on Ic value6.880.675.00 ftDepth to water table (erthq.):Average results interval:Ic cut-off value:Unit weight calculation:Use fill:Fill height:5.00 ft12.60Based on SBTNoN/AFill weight:Transition detect. applied:Kσ applied:Clay like behavior applied:Limit depth applied:Limit depth:N/AYesYesSands onlyYes46.47 ftPA2021-308 This software is licensed to: Stoney-Miller Consultants, IncCPT name: CPT-1CRR plotCRR & CSR0.60.40.20Depth (ft)4644424038363432302826242220181614121086420CRR plotDuring earthq.Liquefaction analysis overall plotsFS PlotFactor of safety21.510.50Depth (ft)4644424038363432302826242220181614121086420FS PlotDuring earthq.Liquefaction potentialLPI20151050Depth (ft)4644424038363432302826242220181614121086420Liquefaction potentialVertical settlementsSettlement (in)10.50Depth (ft)4644424038363432302826242220181614121086420Vertical settlementsLateral displacementsDisplacement (in)2520151050Depth (ft)4644424038363432302826242220181614121086420Lateral displacementsCLiq v.3.3.1.14 - CPT Liquefaction Assessment Software - Report created on: 5/3/2021, 2:36:05 PM5Project file: V:\72450-72999\72572 (Langson) 2676 Bayshore\CPT-Liquefaction\CLiq.clqF.S. color schemeLPI color schemeInput parameters and analysis dataAnalysis method:Fines correction method:Points to test:Earthquake magnitude Mw:Peak ground acceleration:Depth to water table (insitu):NCEER (1998)NCEER (1998)Based on Ic value6.880.675.00 ftDepth to water table (erthq.):Average results interval:Ic cut-off value:Unit weight calculation:Use fill:Fill height:5.00 ft12.60Based on SBTNoN/AFill weight:Transition detect. applied:Kσ applied:Clay like behavior applied:Limit depth applied:Limit depth:N/AYesYesSands onlyYes46.47 ftAlmost certain it will liquefyVery likely to liquefyLiquefaction and no liq. are equally likelyUnlike to liquefyAlmost certain it will not liquefyVery high riskHigh riskLow riskPA2021-308 LIQUEFACTION ANALYSIS REPORT Input parameters and analysis data Analysis method:Fines correction method: Points to test:Earthquake magnitude Mw:Peak ground acceleration: NCEER (1998)NCEER (1998)Based on Ic value6.880.67 G.W.T. (in-situ):G.W.T. (earthq.):Average results interval:Ic cut-off value:Unit weight calculation: Project title : Location : GeoLogismiki Geotechnical Engineers Merarhias 56 http://www.geologismiki.gr CPT file : CPT-2 5.00 ft5.00 ft12.60Based on SBT Use fill:Fill height: Fill weight:Trans. detect. applied:Kσ applied: NoN/AN/AYesYes Clay like behaviorapplied:Limit depth applied:Limit depth:MSF method: Sands onlyYes45.02 ftMethod based Cone resistance qt (tsf)2000Depth (ft)44 42 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 Cone resistance SBTn Plot Ic (Robertson 1990)4321 44 42 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 SBTn Plot CRR plot CRR & CSR 0.60.40.20 44 42 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 CRR plot During earthq. Qtn,cs 200180160140120100806040200Cyclic Stress Ratio* (CSR*)0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 Liquefaction No Liquefact ion Normalized friction ratio (%)0.1 1 10Normalized CPT penetration resistance1 10 100 1,000 Friction Ratio Rf (%)1086420 44 42 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 Friction Ratio Mw=71/2, sigma'=1 atm base curve Summary of liquefaction potential FS Plot Factor of safety 21.510.50 44 42 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 FS Plot During earthq. Zone A1: Cyclic liquefaction likely depending on size and duration of cyclic loading Zone A2: Cyclic liquefaction and strength loss likely depending on loading and ground geometry Zone B: Liquefaction and post-earthquake strength loss unlikely, check cyclic softening Zone C: Cyclic liquefaction and strength loss possible depending on soil plasticity, brittleness/sensitivity, strain to peak undrained strength and ground geometry CLiq v.3.3.1.14 - CPT Liquefaction Assessment Software - Report created on: 5/3/2021, 2:36:38 PM Project file: V:\72450-72999\72572 (Langson) 2676 Bayshore\CPT-Liquefaction\CLiq.clq 1 PA2021-308 This software is licensed to: Stoney-Miller Consultants, IncCPT name: CPT-2Cone resistanceqt (tsf)3002001000Depth (ft)44424038363432302826242220181614121086420Cone resistanceCPT basic interpretation plotsFriction RatioRf (%)1086420Depth (ft)4442403836343230282624222018161412108642Friction RatioPore pressureu (psi)151050-5Depth (ft)44424038363432302826242220181614121086420Pore pressureInsituSBT PlotIc(SBT)4321Depth (ft)4442403836343230282624222018161412108642SBT PlotSoil Behaviour TypeSBT (Robertson et al. 1986)1817161514131211109876543210Depth (ft)44424038363432302826242220181614121086420Soil Behaviour TypeSensitive fine grainedClay & silty clayClay & silty clayClayClay & silty claySand & silty sandSilty sand & sandy siltSand & silty sandSandSandSand & silty sandSandSandSandCLiq v.3.3.1.14 - CPT Liquefaction Assessment Software - Report created on: 5/3/2021, 2:36:38 PM2Project file: V:\72450-72999\72572 (Langson) 2676 Bayshore\CPT-Liquefaction\CLiq.clqInput parameters and analysis dataAnalysis method:Fines correction method:Points to test:Earthquake magnitude Mw:Peak ground acceleration:Depth to water table (insitu):NCEER (1998)NCEER (1998)Based on Ic value6.880.675.00 ftDepth to water table (erthq.):Average results interval:Ic cut-off value:Unit weight calculation:Use fill:Fill height:5.00 ft12.60Based on SBTNoN/AFill weight:Transition detect. applied:Kσ applied:Clay like behavior applied:Limit depth applied:Limit depth:N/AYesYesSands onlyYes45.02 ftSBT legend1. Sensitive fine grained2. Organic material3. Clay to silty clay4. Clayey silt to siltyl5. Silty sand to sandy silt6. Clean sand to silty sand7. Gravely sand to sand8. Very stiff sand told9. Very stiff fine grainedPA2021-308 This software is licensed to: Stoney-Miller Consultants, IncCPT name: CPT-2Norm. cone resistanceQtn200150100500Depth (ft)44424038363432302826242220181614121086420Norm. cone resistanceCPT basic interpretation plots (normalized)Norm. friction ratioFr (%)1086420Depth (ft)44424038363432302826242220181614121086420Norm. friction ratioNom. pore pressure ratioBq10.80.60.40.20-0.2Depth (ft)44424038363432302826242220181614121086420Nom. pore pressure ratioSBTn PlotIc (Robertson 1990)4321Depth (ft)4442403836343230282624222018161412108642SBTn PlotNorm. Soil Behaviour TypeSBTn (Robertson 1990)1817161514131211109876543210Depth (ft)44424038363432302826242220181614121086420Norm. Soil Behaviour TypeOrganic soilClayClayClay & silty claySand & silty sandSandSand & silty sandSandSand & silty sandSand & silty sandSandSandCLiq v.3.3.1.14 - CPT Liquefaction Assessment Software - Report created on: 5/3/2021, 2:36:38 PM3Project file: V:\72450-72999\72572 (Langson) 2676 Bayshore\CPT-Liquefaction\CLiq.clqSBTn legend1. Sensitive fine grained2. Organic material3. Clay to silty clay4. Clayey silt to siltyl5. Silty sand to sandy silt6. Clean sand to silty sand7. Gravely sand to sand8. Very stiff sand told9. Very stiff fine grainedInput parameters and analysis dataAnalysis method:Fines correction method:Points to test:Earthquake magnitude Mw:Peak ground acceleration:Depth to water table (insitu):NCEER (1998)NCEER (1998)Based on Ic value6.880.675.00 ftDepth to water table (erthq.):Average results interval:Ic cut-off value:Unit weight calculation:Use fill:Fill height:5.00 ft12.60Based on SBTNoN/AFill weight:Transition detect. applied:Kσ applied:Clay like behavior applied:Limit depth applied:Limit depth:N/AYesYesSands onlyYes45.02 ftPA2021-308 This software is licensed to: Stoney-Miller Consultants, IncCPT name: CPT-2Total cone resistanceqt (tsf)3002001000Depth (ft)44424038363432302826242220181614121086420Total cone resistanceLiquefaction analysis overall plots (intermediate results)SBTn IndexIc (Robertson 1990)4321Depth (ft)4442403836343230282624222018161412108642SBTn IndexNorm. cone resistanceQtn200150100500Depth (ft)44424038363432302826242220181614121086420Norm. cone resistanceGrain char. factorKc109876543210Depth (ft)44424038363432302826242220181614121086420Grain char. factorCorrected norm. cone resistanceQtn,cs200150100500Depth (ft)44424038363432302826242220181614121086420Corrected norm. cone resistanceCLiq v.3.3.1.14 - CPT Liquefaction Assessment Software - Report created on: 5/3/2021, 2:36:38 PM4Project file: V:\72450-72999\72572 (Langson) 2676 Bayshore\CPT-Liquefaction\CLiq.clqInput parameters and analysis dataAnalysis method:Fines correction method:Points to test:Earthquake magnitude Mw:Peak ground acceleration:Depth to water table (insitu):NCEER (1998)NCEER (1998)Based on Ic value6.880.675.00 ftDepth to water table (erthq.):Average results interval:Ic cut-off value:Unit weight calculation:Use fill:Fill height:5.00 ft12.60Based on SBTNoN/AFill weight:Transition detect. applied:Kσ applied:Clay like behavior applied:Limit depth applied:Limit depth:N/AYesYesSands onlyYes45.02 ftPA2021-308 This software is licensed to: Stoney-Miller Consultants, IncCPT name: CPT-2CRR plotCRR & CSR0.60.40.20Depth (ft)44424038363432302826242220181614121086420CRR plotDuring earthq.Liquefaction analysis overall plotsFS PlotFactor of safety21.510.50Depth (ft)44424038363432302826242220181614121086420FS PlotDuring earthq.Liquefaction potentialLPI20151050Depth (ft)44424038363432302826242220181614121086420Liquefaction potentialVertical settlementsSettlement (in)1.510.50Depth (ft)44424038363432302826242220181614121086420Vertical settlementsLateral displacementsDisplacement (in)20151050Depth (ft)44424038363432302826242220181614121086420Lateral displacementsCLiq v.3.3.1.14 - CPT Liquefaction Assessment Software - Report created on: 5/3/2021, 2:36:38 PM5Project file: V:\72450-72999\72572 (Langson) 2676 Bayshore\CPT-Liquefaction\CLiq.clqF.S. color schemeLPI color schemeInput parameters and analysis dataAnalysis method:Fines correction method:Points to test:Earthquake magnitude Mw:Peak ground acceleration:Depth to water table (insitu):NCEER (1998)NCEER (1998)Based on Ic value6.880.675.00 ftDepth to water table (erthq.):Average results interval:Ic cut-off value:Unit weight calculation:Use fill:Fill height:5.00 ft12.60Based on SBTNoN/AFill weight:Transition detect. applied:Kσ applied:Clay like behavior applied:Limit depth applied:Limit depth:N/AYesYesSands onlyYes45.02 ftAlmost certain it will liquefyVery likely to liquefyLiquefaction and no liq. are equally likelyUnlike to liquefyAlmost certain it will not liquefyVery high riskHigh riskLow riskPA2021-308 LIQUEFACTION ANALYSIS REPORT Input parameters and analysis data Analysis method:Fines correction method: Points to test:Earthquake magnitude Mw:Peak ground acceleration: NCEER (1998)NCEER (1998)Based on Ic value6.880.67 G.W.T. (in-situ):G.W.T. (earthq.):Average results interval:Ic cut-off value:Unit weight calculation: Project title : Location : GeoLogismiki Geotechnical Engineers Merarhias 56 http://www.geologismiki.gr CPT file : CPT-3 5.00 ft5.00 ft12.60Based on SBT Use fill:Fill height: Fill weight:Trans. detect. applied:Kσ applied: NoN/AN/AYesYes Clay like behaviorapplied:Limit depth applied:Limit depth:MSF method: Sands onlyYes22.02 ftMethod based Cone resistance qt (tsf)2000Depth (ft)22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Cone resistance SBTn Plot Ic (Robertson 1990)4321 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 SBTn Plot CRR plot CRR & CSR 0.60.40.20 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 CRR plot During earthq. Qtn,cs 200180160140120100806040200Cyclic Stress Ratio* (CSR*)0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 Liquefaction No Liquefact ion Normalized friction ratio (%)0.1 1 10Normalized CPT penetration resistance1 10 100 1,000 Friction Ratio Rf (%)1086420 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Friction Ratio Mw=71/2, sigma'=1 atm base curve Summary of liquefaction potential FS Plot Factor of safety 21.510.50 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 FS Plot During earthq. Zone A1: Cyclic liquefaction likely depending on size and duration of cyclic loading Zone A2: Cyclic liquefaction and strength loss likely depending on loading and ground geometry Zone B: Liquefaction and post-earthquake strength loss unlikely, check cyclic softening Zone C: Cyclic liquefaction and strength loss possible depending on soil plasticity, brittleness/sensitivity, strain to peak undrained strength and ground geometry CLiq v.3.3.1.14 - CPT Liquefaction Assessment Software - Report created on: 5/3/2021, 2:37:09 PM Project file: V:\72450-72999\72572 (Langson) 2676 Bayshore\CPT-Liquefaction\CLiq.clq 1 PA2021-308 This software is licensed to: Stoney-Miller Consultants, IncCPT name: CPT-3Cone resistanceqt (tsf)3002001000Depth (ft)22212019181716151413121110987654321Cone resistanceCPT basic interpretation plotsFriction RatioRf (%)1086420Depth (ft)212019181716151413121110987654321Friction RatioPore pressureu (psi)6420Depth (ft)22212019181716151413121110987654321Pore pressureInsituSBT PlotIc(SBT)4321Depth (ft)212019181716151413121110987654321SBT PlotSoil Behaviour TypeSBT (Robertson et al. 1986)1817161514131211109876543210Depth (ft)22212019181716151413121110987654321Soil Behaviour TypeSensitive fine grainedSand & silty sandSand & silty sandSilty sand & sandy siltSand & silty sandSilty sand & sandy siltClaySilty sand & sandy siltSand & silty sandCLiq v.3.3.1.14 - CPT Liquefaction Assessment Software - Report created on: 5/3/2021, 2:37:09 PM2Project file: V:\72450-72999\72572 (Langson) 2676 Bayshore\CPT-Liquefaction\CLiq.clqInput parameters and analysis dataAnalysis method:Fines correction method:Points to test:Earthquake magnitude Mw:Peak ground acceleration:Depth to water table (insitu):NCEER (1998)NCEER (1998)Based on Ic value6.880.675.00 ftDepth to water table (erthq.):Average results interval:Ic cut-off value:Unit weight calculation:Use fill:Fill height:5.00 ft12.60Based on SBTNoN/AFill weight:Transition detect. applied:Kσ applied:Clay like behavior applied:Limit depth applied:Limit depth:N/AYesYesSands onlyYes22.02 ftSBT legend1. Sensitive fine grained2. Organic material3. Clay to silty clay4. Clayey silt to siltyl5. Silty sand to sandy silt6. Clean sand to silty sand7. Gravely sand to sand8. Very stiff sand told9. Very stiff fine grainedPA2021-308 This software is licensed to: Stoney-Miller Consultants, IncCPT name: CPT-3Norm. cone resistanceQtn200150100500Depth (ft)22212019181716151413121110987654321Norm. cone resistanceCPT basic interpretation plots (normalized)Norm. friction ratioFr (%)1086420Depth (ft)22212019181716151413121110987654321Norm. friction ratioNom. pore pressure ratioBq10.80.60.40.20-0.2Depth (ft)22212019181716151413121110987654321Nom. pore pressure ratioSBTn PlotIc (Robertson 1990)4321Depth (ft)212019181716151413121110987654321SBTn PlotNorm. Soil Behaviour TypeSBTn (Robertson 1990)1817161514131211109876543210Depth (ft)22212019181716151413121110987654321Norm. Soil Behaviour TypeSensitive fine grainedSand & silty sandSand & silty sandSandSand & silty sandSilty sand & sandy siltClay & silty claySand & silty sandSandSand & silty sandCLiq v.3.3.1.14 - CPT Liquefaction Assessment Software - Report created on: 5/3/2021, 2:37:09 PM3Project file: V:\72450-72999\72572 (Langson) 2676 Bayshore\CPT-Liquefaction\CLiq.clqSBTn legend1. Sensitive fine grained2. Organic material3. Clay to silty clay4. Clayey silt to siltyl5. Silty sand to sandy silt6. Clean sand to silty sand7. Gravely sand to sand8. Very stiff sand told9. Very stiff fine grainedInput parameters and analysis dataAnalysis method:Fines correction method:Points to test:Earthquake magnitude Mw:Peak ground acceleration:Depth to water table (insitu):NCEER (1998)NCEER (1998)Based on Ic value6.880.675.00 ftDepth to water table (erthq.):Average results interval:Ic cut-off value:Unit weight calculation:Use fill:Fill height:5.00 ft12.60Based on SBTNoN/AFill weight:Transition detect. applied:Kσ applied:Clay like behavior applied:Limit depth applied:Limit depth:N/AYesYesSands onlyYes22.02 ftPA2021-308 This software is licensed to: Stoney-Miller Consultants, IncCPT name: CPT-3Total cone resistanceqt (tsf)3002001000Depth (ft)22212019181716151413121110987654321Total cone resistanceLiquefaction analysis overall plots (intermediate results)SBTn IndexIc (Robertson 1990)4321Depth (ft)212019181716151413121110987654321SBTn IndexNorm. cone resistanceQtn200150100500Depth (ft)22212019181716151413121110987654321Norm. cone resistanceGrain char. factorKc109876543210Depth (ft)22212019181716151413121110987654321Grain char. factorCorrected norm. cone resistanceQtn,cs200150100500Depth (ft)22212019181716151413121110987654321Corrected norm. cone resistanceCLiq v.3.3.1.14 - CPT Liquefaction Assessment Software - Report created on: 5/3/2021, 2:37:09 PM4Project file: V:\72450-72999\72572 (Langson) 2676 Bayshore\CPT-Liquefaction\CLiq.clqInput parameters and analysis dataAnalysis method:Fines correction method:Points to test:Earthquake magnitude Mw:Peak ground acceleration:Depth to water table (insitu):NCEER (1998)NCEER (1998)Based on Ic value6.880.675.00 ftDepth to water table (erthq.):Average results interval:Ic cut-off value:Unit weight calculation:Use fill:Fill height:5.00 ft12.60Based on SBTNoN/AFill weight:Transition detect. applied:Kσ applied:Clay like behavior applied:Limit depth applied:Limit depth:N/AYesYesSands onlyYes22.02 ftPA2021-308 This software is licensed to: Stoney-Miller Consultants, IncCPT name: CPT-3CRR plotCRR & CSR0.60.40.20Depth (ft)22212019181716151413121110987654321CRR plotDuring earthq.Liquefaction analysis overall plotsFS PlotFactor of safety21.510.50Depth (ft)22212019181716151413121110987654321FS PlotDuring earthq.Liquefaction potentialLPI20151050Depth (ft)22212019181716151413121110987654321Liquefaction potentialVertical settlementsSettlement (in)0.250.20.150.10.050Depth (ft)22212019181716151413121110987654321Vertical settlementsLateral displacementsDisplacement (in)43210Depth (ft)22212019181716151413121110987654321Lateral displacementsCLiq v.3.3.1.14 - CPT Liquefaction Assessment Software - Report created on: 5/3/2021, 2:37:09 PM5Project file: V:\72450-72999\72572 (Langson) 2676 Bayshore\CPT-Liquefaction\CLiq.clqF.S. color schemeLPI color schemeInput parameters and analysis dataAnalysis method:Fines correction method:Points to test:Earthquake magnitude Mw:Peak ground acceleration:Depth to water table (insitu):NCEER (1998)NCEER (1998)Based on Ic value6.880.675.00 ftDepth to water table (erthq.):Average results interval:Ic cut-off value:Unit weight calculation:Use fill:Fill height:5.00 ft12.60Based on SBTNoN/AFill weight:Transition detect. applied:Kσ applied:Clay like behavior applied:Limit depth applied:Limit depth:N/AYesYesSands onlyYes22.02 ftAlmost certain it will liquefyVery likely to liquefyLiquefaction and no liq. are equally likelyUnlike to liquefyAlmost certain it will not liquefyVery high riskHigh riskLow riskPA2021-308 APPENDIX E STANDARD GRADING SPECIFICATIONS PA2021-308 APPENDIX E STANDARD GRADING SPECIFICATIONS GENERAL These specifications present the usual and minimum requirements for grading operations observed by Geofirm or its designated representative. No deviation from these specifications will be allowed, except where specifically superseded in the geotechnical report signed by a registered geotechnical engineer. The placement, spreading, mixing, watering and compaction of the fills in strict accordance with these guidelines shall be the sole responsibility of the contractor. The construction, excavation, and placement of fill shall be under the direct observation of the soils engineer signing the soils report. If unsatisfactory soil-related conditions exist, the soils engineer shall have the authority to reject the compacted fill ground and, if necessary, excavation equipment will be shut down to permit completion of compaction. Conformance with these specifications will be discussed in the final report issued by the soils engineer. SITE PREPARATION All brush, vegetation and other deleterious material such as rubbish shall be collected, piled and removed from the site prior to placing fill, leaving the site clear and free from objectionable material. Soil, alluvium, or rock materials determined by the soils engineer as being unsuitable for placement in compacted fills shall be removed from the site. Any material incorporated as part of a compacted fill must be approved by the soils engineer. The surface shall then be plowed or scarified to a minimum depth of 6 inches until the surface is free from uneven features that would tend to prevent uniform compaction by the equipment used. After the area to receive fill has been cleared and scarified, it shall be diced or bladed by the contractor until it is uniform and free from large clods, brought to the proper moisture content and compacted to minimum requirements. If the scarified zone is greater than 12 inches in depth, the excess shall be removed and placed in lifts restricted to 6 inches. Any underground structures such as cesspools, cisterns, mining shafts, tunnels, septic tanks, wells, pipe lines or others not located prior to grading are to be removed or treated in a manner prescribed by the soils engineer. MATERIALS Materials for compacted fill shall consist of materials approved by the soils engineer. These materials may be excavated from the cut area or imported from other approved sources, and soils from one or more sources may be blended. Fill soils shall be free from organic vegetable matter and other unsuitable substances. Normally, the material shall contain no rocks or hard lumps PA2021-308 greater than 6 inches in size and shall contain at least 50 percent of material smaller than 1/4- inch in size. Materials greater than 4 inches in size shall be placed so that they are completely surrounded by compacted fines; no nesting of rocks shall be permitted. No material of a perishable, spongy, or otherwise of an unsuitable nature shall be used in the fill soils. Representative samples of materials to be utilized as compacted fill shall be analyzed in the laboratory by the soils engineer to determine their physical properties. If any material other than that previously tested is encountered during grading, the appropriate analysis of this material shall be conducted by the geotechnical engineer as soon as possible. PLACING, SPREADING, AND COMPACTING FILL MATERIAL The material used in the compacting process shall be evenly spread, watered, processed and compacted in thin lifts not to exceed 6 inches in thickness to obtain a uniformly dense layer. When the moisture content of the fill material is below that specified by the soils engineer, water shall be added by the contractor until the moisture content is near optimum as specified. When the moisture content of the fill material is above that specified by the geotechnical engineer, the fill material shall be aerated by the contractor by blading, mixing, or other satisfactory methods until the moisture content is near optimum as specified. After each layer has been placed, mixed, and spread evenly, it shall be thoroughly compacted to 90 percent of the maximum laboratory density in compliance with ASTM D: 1557-70 (five layers). Compaction shall be accomplished by sheepsfoot rollers, vibratory rollers, multiple- wheel pneumatic-tired rollers, or other types of acceptable compacting equipment. Equipment shall be of such design that it will be able to compact the fill to the specified density. Compaction shall be continuous over the entire area and the equipment shall make sufficient passes to obtain the desired density uniformly. A minimum relative compaction of 90 percent out to the finished slope face of all fill slopes will be required. Compacting of the slopes shall be accomplished by backrolling the slopes in increments of 2 to 5 feet in elevation gain or by overbuilding and cutting back to the compacted inner core, or by any other procedure which produces the required compaction. OBSERVATIONS AND TESTING The geotechnical engineer shall observe the placement of fill during the grading process and will file a written report upon completion of grading stating his observations as to compliance with these specifications. One density test shall be required for each 2 vertical feet of fill placed, or one for each 1,000 cubic yards of fill, whichever requires the greater number of tests. PA2021-308 Any cleanouts and processed ground to receive fill must be observed by the soils engineer and/or engineering geologist prior to any fill placement. The contractor shall notify the geotechnical engineer when these areas are ready for observation. PROTECTION OF WORK During the grading process and prior to the complete construction of permanent drainage controls, it shall be the responsibility of the contractor to provide good drainage and prevent ponding of water and damage to adjoining properties or to finished work on the site. After the geotechnical engineer has terminated his observations of the completed grading, no further excavations and/or filling shall be performed without the approval of the soils engineer, if it is to be subject to the recommendations of this report. PA2021-308 APPENDIX F UTILITY TRENCH BACKFILL GUIDELINES PA2021-308 APPENDIX F UTILITY TRENCH BACKFILL GUIDELINES The following guidelines pertinent to utility trench backfills have been adopted by the County of Orange, Environmental Management Agency Grading Section, effective March 31, 1986. The application of the guidelines is strictly enforced by the County reviewers and inspectors. 1. Each utility subcontractor (gas, electric, water, sewer, telephone, cable TV, irrigation, drainage, etc.) shall submit to the developer for dissemination to his consultants (civil engineer, geotechnical engineer, and utility contractor) a plot plan of utility lines installed under his purview which identifies line type, material, size, depth, and approximate location. 2. The developer or his agent shall provide a composite plot plan of all utilities or a copy of all individual utility plot plans to his geotechnical engineer for use in evaluating whether all utility trench backfills are suitable for the intended use. 3. The geotechnical engineer shall provide the County with a report which includes a plot plan showing the location of all utility trenches which: A. Are located within the load influence zone of a structure (1:1 projection) B. Are located beneath any hardscape C. Are parallel and in close proximity to the top or toe of a slope and may adversely impact slope stability if improperly backfilled D. Are located on the face of a slope in a trench 18 or more inches in depth. Typically, trenches that are less than 18 inches in depth will not be within the load influence zone if located next to a structure, and will not have a significant effect on slope stability if constructed near the top or toe of a slope and need not be shown on the plot plan unless determined to be significant by the geotechnical engineer. This plot plan may be prepared by someone other than the soil engineer, but must meet his approval. 4. Backfill compaction test locations must be shown on the plot plan described in No. 3 above, and a table of test data provided in the geotechnical report. 5. The geotechnical report (utility trench backfill) must state that all utility trenches within the subject lots have been backfilled in a manner suitable for the intended use. This includes the backfill of all trenches shown on the plot plan described in No. 3 and the backfill of those trenches which did not need to be plotted on this plan. PA2021-308