HomeMy WebLinkAboutPA2022-011_20220110_Plans_30x42ALUMINUM
CONCRETE
EARTH
GYPSUM -PLASTER
INSULATION -RIGID
MASONRY -BRICK/STONE
MASONRY -STONE/COMP. PANELING
PLYWOOD / GLU-LAM TIMBER
SAND
STEEL
WOOD
Name
Elevation
A101
1 SIM
Room name
150 SF
101
1i
?
90 00' 00"
Distance
N E
1
1
A101
SIM
R @7 1/2"20
1i
NORTH ARROW
PROPERTY LINE TAG
SECTION INDICATOR
ROOM TAG (NAME / AREA)
CALL-OUT TAG
ELEVATION INDICATOR
KEYNOTE TAG
WINDOW TAG
DOOR TAG
WALL TAG
REVISION FLAG
STAIR TAG (NO. OF RISER & HEIGHT)
BUILDING ASSEMBLIES REQ'D. FIRE RESISTANCE
BEARING WALLS - EXTERIOR/ INTERIOR
ASSEMBLY
2-HR/ 1-HR
FLOOR CONSTRUCTION & ASSOC. SECONDARY MEMBERS 1-HR
REQ'D.
RATING
ROOF CONSTRUCTION & ASSOC. SECONDARY MEMBERS 1-HR
PRIMARY STRUCTURAL FRAME 1-HR
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
01/07/21
TITLE SHEET110 22ND STREETMCFADDEN PLACE, LLC.
MR. MARIO MAROVIC,
MANAGING MEMBER
3334 E. COAST HWY #418
CORONA DEL MAR, CA 92625
DRC
106-110 22ND STREET, NEWPORT
BEACH, CA 92663
T-1.0
DEFERRED SUBMITTALS
9
110 22ND STREET
106-110 22ND STREET, NEWPORT BEACH, CA 92663
PROJECT STATISTICS 6 3 1
2
10
11VICINITY MAP/ PROJECT DISCRIPTION
MATERIAL LEGEND
ANNOTATION LEGEND CODE REVIEW
BUILDING AREA SCHEDULE
LOCATION AREA COMMENTS
COMMERCIAL SUITE '1' 683 SF
COMMERCIAL SUITE '2' 654 SF
COMMERCIAL SUITE '3' 691 SF
EXIT PASSAGEWAY 192 SF
UTILITY 259 SF
2480 SF
L1 8 SF 2ND FLR. LANDING AREA
L2 31 SF 2ND FLR. LANDING AREA
L3 113 SF 3RD FLR. ELEVATOR LOBBY
LOBBY 261 SF
RESIDENTIAL UNIT 'A' 1989 SF
RESIDENTIAL UNIT 'B' 1905 SF
RESIDENTIAL UNIT 'C' 2775 SF
7082 SF
GRAND TOTAL 9561 SF
LEGAL DESCRIPTION:
LOT 9, 10 &11, BLOCK 21
APN: 047-151-04, 047-151-05, 047-151-06
LOT INFORMATION:
EXISTING BUILDING INFORMATION:
(3) EXISTING STRUCTURES OF APPX. 2,886.50 S.F. TO BE DEMOLISHED
REF. 9/T-1FLOOR AREA
BUILDING TO BE SPRINKLERED THROUGHOUT,
NON-SEPARATED MIXED OCCUPANCIES
NFPA 13 COMMERCIAL SYSTEM PER SECTION 903.3.1.1 OF 2016 CBC
R-2/U/M
'MIXED USE NON-SEPARATED OCCUPANCY'PER 508.3
CODES:
OCCUPANCY CLASSIFICATIONS
OCCUPANT LOAD
NOTE: DEFERRED SUBMITTALS TO BE REVIEWED BY PROJECT ARCHITECT OR
ENGINEER OF RECORD AND CERTIFIED PRIOR TO SUBMITTAL TO LOCAL
AGENCY FOR REVIEW.
C.N.B. NOTE: BRANDON ARCHITECTS, INC. IS THE DESIGN PROFESSIONAL IN
RESPONSIBLE CHARGE OF THE PROJECT, RESPONSIBLE FOR REVIEWING AND
COORDINATING SUBMITTAL DOCUMENTS PREPARED BY OTHERS, INCLUDING
PHASED AND DEFERRED SUBMITTAL ITEMS, FOR COMPATIBILITY WITH THE
DESIGN OF THE BUILDING. (NBMC 15.02.010)
DIG ALERT: 1.800.227.2600
SOUTHERN CALIFORNIA EDISON: 1.714.895.0246
SOUTHERN CALIFORNIA GAS: 1.800.427.2000
CITY WATER & SEWER: 949.644.3011
PACIFIC BELL TELEPHONE: 1.800.750.2355
CITY OF NEWPORT BEACH PUBLIC WORKS DEPT.
F: (949) 644-3318 P: (949) 644-3311
CITY OF NEWPORT BEACH PLANNING DEPT.:
General Information Line : (949)644-3200
Zoning Information Line: (949)644-3204
CITY OF NEWPORT BEACH BUILDING DEPT.:
(949) 644-3275 General Administration
(949) 644-3288 Permit Counter
(949) 644-3255 Inspection Requests
NEWPORT BEACH FIRE DEPARTMENT:
3300 NEWPORT BLVD. NEWPORT BEACH, CA 92658
P: 949.644.3106
ORANGE COUNTY HEALTH SERVICES:
PO BOX 355 SANTA ANA, CA 92702
P: 714.834.3882
1.POOLS, SPAS, WALLS, FENCES, PATIO COVERS AND OTHER
FREESTANDING STRUCTURES REQUIRE SEPARATE REVIEWS AND
PERMITS EXCEPT FOR ROOF TOP SPA.
2.SUBMIT SOUND ATTENUATION DESIGN FOR HVAC EQUIPMENT
PER ARI STD. 275. SOUND LEVEL NOT TO EXCEED 50dBA (55dBA
WITH TIMER, 65dBA WITH TIMER AND NEIGHBORS CONSENT).
LOCATION OF MEASUREMENT TO BE AT ADJACENT PROPERTY
PATIO OR OPENING.
3.A CAL-OSHA PERMIT IS REQUIRED FOR EXCAVATIONS DEEPER
THAN 5' AND FOR SHORING AND UNDERPINNING. CONTRACTOR TO
PROVIDE A COPY OF OSHA PERMIT.
4. BUILDING REQUIRES A FIRE SPRINKLER SYSTEM, OBTAIN FIRE
SPRINKLER PERMIT PRIOR TO CALLING FOR ROOF SHEATHING
INSPECTION.
5. FIRE ALARM AND UNDERGROUND FIRE LINE TO BE BY SEPARATE
PERMIT AS REQUIRED IN CBC SECTION 907.2.9.
PROJECT DESCRIPTION:
THE SUBJECT PROPERTY IS LOCATED IN NEWPORT BEACH, CA ON 22ND STREET SOUTHWEST OF BALBOA BLVD
LOCATED ON THE BALBOA PENINSULA. THE LOT IS APPROXIMATELY 75’WIDE BY 95’DEEP, IT IS ZONED MU-W2
(MIXED USE WATER RELATED) AND IS APPX. 7,082.9 S.F. THE EXISTING PROPERTY CONSISTS OF (3) SEPARATE
LOTS USED FOR RETAIL/MIXED-USE WITH (3) UNCOVERED PARKING STALLS PROVIDED PER CNB STANDARD.
CLIENT PROPOSES TO DEMOLISH EXISTING STRUCTURES OF APPX. 2,886.5 S.F. IN TOTAL AND MERGE LOTS INTO
A SINGLE PROPERTY. CLIENT PROPOSES TO CONSTRUCT A NEW THREE-STORY MIXED-USE BUILDING
CONSISTING OF APPX. 2,480 SF OF COMMERCIAL SPACE AND 7,082 SF. OF RESIDENTIAL. BUILDING WILL BE TYPE
III-A CONSTUCTION TO BE LIGHT GAUGE STEEL FRAMING (NON-CUMBUSTIBLE). THE PROJECT WILL BE OF A
CONTEMPORARY DESIGN, INCLUDING: (3) RETAIL SUITES AT THE GROUND LEVEL AND (3) RESIDENTIAL
CONDOMINIUMS ON THE SECOND AND THIRD LEVEL. RESIDENCES TO INCLUDE, BUT NOT LIMITED TO, THE
FOLLOWING: (3) BEDROOMS, (3.5) BATHS, AMPLE INDOOR/OUTDOOR LIVING SPACES INTEGRATED WITH A
MODERN ‘OPEN’LIVING FLOOR PLAN WHICH MAXIMIZES POTENTIAL VIEWS FROM LIVING SPACES AS WELL AS
OUTDOOR DECKS AND BALCONIES. PARKING WILL BE PROVIDED IN THE FORM OF (2) SEPARATE COVERED
CARPORTS CONSISTING OF : (3) COMMERCIAL PARKING STALLS (INCLUDING 1 VAN ACCESSIBLE STALL) AND (7)
RESIDENTIAL PARKING STALLS (INCLUDING 1 GUEST STALL). THE EXTERIOR WILL BE PRIMARILY STUCCO SIDING,
STONE/COMPOSITE PANELING, AND SOME USE OF METAL AND EXPOSED STRUCTURAL ELEMENTS.
OUTDOOR AREA SCHEDULE
LOCATION AREA COMMENTS
UNIT 'A' BALCONY 108 SF
UNIT 'A' BALCONY 2 35 SF
UNIT 'A' DECK 249 SF
UNIT 'B' DECK 319 SF
UNIT 'C' BALCONY 368 SF
UNIT 'C' VIEW DECK 583 SF
1661 SF
COURTYARD 274 SF
274 SF
GRAND TOTAL 1936 SF
ZONING INFORMATION
GRAND TOTAL BUILDING AREA = 9,561.57 S.F.
NBMC (NEWPORT BEACH MUNICIPAL CODE)
CALIFORNIA CODES: 2019 CBC, 2019 CFC, 2019 CEC,
2019 CPC, 2019 CAL GREEN, 2019 BEES AND 2019 CMC
SHEET LISTPLUMBING REQUIREMENT
FRONT SETBACK:0 FT.
REAR SETBACK:10'-0" FT. (ALLEY)
LEFT SETBACK:0 FT.
RIGHT SETBACK:0 FT.
OWNER: ARCHITECT:
BRANDON ARCHITECTS, INC.
CHRISTOPHER BRANDON, PRINCIPAL
151 KALMUS DR. STE. G-1
COSTA MESA, CA 92626
P: 714.754.4040 F: 714.754.4004
www.BrandonArchitects.com
STRUCTURAL ENGINEER:CIVIL ENGINEER:
GENERAL CONTRACTOR:
TBD
INTERIOR DESIGNER:
TBD
SURVEYOR:SOILS ENGINEER:
11
8
PROJECT DIRECTORY
7SPECIAL INSPECTIONSBRANDON ARCHITECTS COMMERCIAL TOTAL
1. REF. STRUCTURAL DRAWINGS FOR OBSERVATION SCHEDULE &
SPECIAL INSPECTIONS
2. FIELD TEST SOUND SUPPRESSING RECESSED CAN LIGHTS
SPECIFIED IN DTL. 4/AD-2 STC TO BE 45 OR GREATER BETWEEN
UNITS, AFTER INSTALLATION.
TBD
SITE
APEX LAND SURVEYING, INC.
PAUL D. CRAFT, P.L.S.
8512 OXLEY CIRCLE
HUNTINGTON BEACH, CA 92646
P: 714.488.5006
F: 714.333.4440
E: APEXLSINC@GMAIL.COM
RESIDENTIAL TOTAL
GRAND TOTAL
COMMERCIAL TOTAL = 2,479.60 S.F.
RESIDENTIAL TOTAL = 7,081.97 S.F.
MCFADDEN PLACE, LLC.
MR. MARIO MAROVIC, MANAGING MEMBER
3334 E. COAST HWY #418
CORONA DEL MAR, CA 92625
TBD TBD
SUM OF ACTUAL AREA/ALLOWABLE AREA ≤1 (FOR EACH OCCUPANCY)
5SITE & ZONING INFORMATION
COMMERCIAL MIN. REQ'D. PLUMBING FIXTURES FOR OCCUPANT LOAD ≤50
(PER TABLE 422.1 OF 2013 CPC)
W/C.LAVATORIES DRINKING
FOUNTAIN OTHERS
REQ'D.
PROVIDED
M
1 1 1 SERVICE SINK/
LAUNDRY TRAY1
1 1 1
FLOOR MOP SINK1
MAX. FLOOR AREA, NO. OF STORIES AND HT.
PER TABLES 504.3-4 & 506.2:
REF. A/A-2.0
PROVIDED NO. STORIES (REF. 508.4.3):
MAX. HT.65'
M 55,500 SF & 5 STORY MAX
R-2 72,000 SF & 5 STORY MAX
S-2 117,000 SF & 5 STORY MAX
MAX BUILDING AREA PER 508.4.2:
FIRST FLOOR
2,483 SF/55,500 SF= 0.04 M
2,783 SF/117,000 SF= 0.02S-2
2ND & 3RD FLOOR
N/AR-2
BLDG HT. (REF. 508.4.3)ACTUAL= 35' ≤65'
M 1 ≤5 STORY MAX
R-2 2 ≤5 STORY MAX
S-2 1 ≤5 STORY MAX
SEPARATION (508.4.4.1)REF. A/A-2.0 FOR MORE INFO
CONSTRUCTION TYPE III-A
4AGENCIES & PUBLIC SERVICES
HEIGHT
ALLOWABLE BLDG. AREA (PER MU-W2/SB 478)
MAX RESIDENTIAL 7,082.9 SF
MIN. COMMERCIAL 2,479.02 SF
MAX FLAT 30'
MAX SLOPED 35' (3:12 MIN.)
(PER VARIANCE)
TOTAL 'M' OCCUPANT LOAD ≤49, PER SECTION 1021.2.1 JUST ONE EXIT REQUIRED
TOTAL EXITS PROVIDED 1
REQ'D. NUMBER OF EXITS REF. A/A-2.0 FOR MORE INFO
COMMERCIAL UNITS #1-3
TOTAL NUMBER OF DWELLING UNITS ≤4 PER TABLE 1006.3.2(1)JUST ONE
EXIT REQUIRED
TOTAL EXITS PROVIDED 1
RESIDENTIAL UNITS A-C
TTL. PRIVATE OUTDOOR
ZONED: MU-W2
SITE AREA:7,082.90 S.F.
AREA FAR REQUIREMENTS: 1.0 MAX RESIDENTIAL (SB 478)
0.35 MIN. AND 0.50 MAX COMMERCIAL
10,624.35 MAXIMUM ALLOWABLE BUILDING AREA
(9,561.57 S.F. PROPOSED)
RESIDENTIAL ALLOWABLE PER SB 478: 1.0 X 7,082.9 = 7,082.9 S.F.
COMMERCIAL ALLOWABLE: 0.5 MIN. X 7,082.9 = 3,541.45 S.F. (2,479.60 S.F. PROVIDED)
(9,561.57 S.F. ACTUAL REF. AP-1)
.02 + .04 = .06 ≤1
SHEET #DRAWING TITLE
T-1.0 TITLE SHEET
T-1.1 GENERAL ARCHITECTURAL NOTES
T-1.2 GENERAL ARCHITECTURAL NOTES
T-1.3 GENERAL ARCHITECTURAL NOTES
A-0.0 ARCHITECTURAL SITE PLAN
SUR TOPOGRAPHIC SURVEY
A-1.0 3-DIMENSIONAL VIEWS
A-2.1 FIRST LEVEL FLOOR PLAN
A-2.2 SECOND LEVEL FLOOR PLAN
A-2.3 THIRD LEVEL FLOOR PLAN
A-3.0 ROOF PLAN & DETAILS
A-4.0 EXTERIOR ELEVATIONS
A-4.1 EXTERIOR ELEVATIONS
AP-1 AREA PLANS
TTL. COMMON OPEN SPACE
GRAND TOTAL
(2,479.60 S.F. ACTUAL REF. AP-1)
NO. REVISION DATE
(7,081.97 S.F. ACTUAL REF. AP-1)
PA2022-011
DEFINITIONS: (AS USED IN THESE SPECIFICATIONS)
OWNER SHALL MEAN: **MCFADDEN PLACE, LLC. **
ARCHITECT SHALL MEAN: BRANDON ARCHITECTS, INC., **RYAN MCDANIEL, PRINCIPAL ARCHITECT**
CONTRACTOR SHALL MEAN:LICENSED GENERAL CONTRACTOR HIRED TO PERFORM THE WORK UNDER THIS CONTRACT
SPECIFICATIONS SHALL MEAN:WRITTEN SPECIFICATIONS IN THE PLANS OR THE "PROJECT MANUAL" (IF PROVIDED FOR THIS PROJECT)
CONTRACT DOCUMENTS SHALL MEAN: WORKING DRAWINGS APPROVED FOR BUILDING PERMIT, PLUS ANY CHANGE ORDERS OR ADDENDA TO SAME.
ARCHITECTURAL GENERAL NOTES:
1. CODES/GENERAL PROVISIONS: ALL WORK, CONSTRUCTION AND MATERIALS SHALL COMPLY WITH ALL PROVISIONS OF THE APPLICABLE BUILDING CODES AND WITH OTHER RULES, REGULATIONS AND ORDINANCES GOVERNING THE PLACE OF
CONSTRUCTION. IT IS THE RESPONSIBILITY OF THE CONTRACTOR, SUB-CONTRACTORS, AND ANYONE SUPPLYING LABOR AND/OR MATERIAL TO BRING TO THE ATTENTION OF THE ARCHITECT (VERBALLY AND IN WRITING) ANY KNOWN DISCREPANCIES OR
CONFLICT BETWEEN THE REQUIREMENTS OF THESE CODES AND THE CONTRACT DOCUMENTS (DRAWINGS). THE APPLICABLE CODES SHALL INCLUDE, BUT SHALL NOT BE LIMITED TO THOSE AS LISTED IN "CODE REVIEW" BOX. (T-1.0)
ALL WORK SHALL BE PERFORMED SO AS TO COMPLY WITH ALL LEGAL AND INDUSTRY REQUIREMENTS AND STANDARDS INCLUDING THE FOLLOWING:
-THE CALIFORNIA BUILDING CODES, 2019 EDITIONS, AND ALL APPLICABLE RELATED SPECIALTY CODES.
-THE FUNCTIONALITY STANDARDS SET FORTH IN TITLE 7 OF THE CALIFORNIA CIVIL CODE (THE "RIGHT TO REPAIR ACT").
-THE CITY OF DANA POINT MUNICIPAL CODE INCLUDING ANY WORK TIME RESTRICTION AND ANY AMENDMENT TO CALIFRONIA BUILDING CODES.
-THE MANUFACTURER'S REQUIREMENTS OF RECOMMENDATIONS FOR ANY INCORPORATED PRODUCTS.
2. FEES: CONTRACTOR AND HIS SUB-CONTRACTORS SHALL OBTAIN AND PAY FOR ALL PERMITS, LICENSES, CONSTRUCTION TAXES AND FEES REQUIRED BY CITY, COUNTY AND STATE LAWS EXCEPT THE GENERAL BUILDING PLAN CHECK FEE AND REQUIRED
REFUNDABLE DEPOSITS WHICH WILL BE PAID BY THE OWNER. CONTRACTOR SHALL ARRANGE FOR ALL METER INSTALLATIONS AND PAY ALL FEES FOR SAID METERS. CONTRACTOR SHALL PROVIDE TEMPORARY TOILET FACILITIES AND EROSION CONTROL
MEASURES AS REQUIRED BY STATE AND LOCAL BUILDING CODE.
3. CONTRACTOR'S SURVEY: CONTRACTOR SHALL VISIT THE JOB SITE AND BE RESPONSIBLE FOR HAVING COMPLETE KNOWLEDGE OF EXISTING CONDITIONS. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS WITH THOSE SHOWN ON THE DRAWINGS AND
SHALL VERIFY GRADES, CONDITIONS AND DIMENSIONS PRIOR TO COMMENCING DEMOLITION AND CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY VERBALLY AND IN WRITING OF DISCREPANCIES BETWEEN ACTUAL CONDITIONS AND
THOSE DEPICTED IN THE CONTRACT DOCUMENTS. CONTRACTOR SHALL NOTIFY ARCHITECT IMMEDIATELY VERBALLY AND IN WRITING OF ANY DISCREPANCIES FOUND WITHIN THE DRAWINGS AND SPECIFICATIONS.
4. COORDINATION OF CONSTRUCTION: CONTRACTOR IS SOLELY RESPONSIBLE FOR THE ACCURACY OF DETAILS; FOR CONFIRMING AND COORDINATING ALL QUANTITIES AND DIMENSIONS; FOR SELECTING FABRICATION PROCESSES; FOR TECHNIQUES OF
ASSEMBLY AND PERFORMANCE OF ALL WORK IN A SAFE AND SATISFACTORY MANNER. CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF ALL WORK INCLUDING THAT OF THE SUB-CONTRACTORS. CONTRACTOR SHALL PROVIDE SUPERVISION OF
THE JOB DURING ALL PHASES OF CONSTRUCTION ACTIVITIES. A COMPETENT SUPERINTENDENT SHALL BE SELECTED BY THE CONTRACTOR AND SHALL BE IN CHARGE OF THE JOB UNTIL ITS COMPLETION. CONTRACTOR AGREES TO BIND EVERY SUB-
CONTRACTOR BY THE TERMS OF THE CONTRACT AS FAR AS SUCH TERMS ARE APPLICABLE TO THE SUB-CONTRACTOR'S WORK.
5. CLEAN-UP: ALL SUBCONTRACTORS SHALL BE RESPONSIBLE FOR THE DAILY REMOVAL OF ALL DEBRIS ACCUMULATED AS A RESULT OF THEIR OPERATIONS. ALL SCRAP DEBRIS AND OTHER EXCESS MATERIAL SHALL BE LAWFULLY REMOVED FROM THE SITE,
UNLESS OTHERWISE DIRECTED BY THE CONTRACTOR.
6. TESTS AND PERMITS: CONTRACTOR SHALL ARRANGE FOR, AND SECURE REQUIRED TESTS, PERMITS AND INSPECTIONS, AND SHALL BEAR COSTS FOR SAME.
7. GUARANTEES: CONTRACTOR SHALL GUARANTEE ALL WORK, MATERIALS AND PRODUCTS FOR ONE YEAR AFTER THE DATE OF ACCEPTANCE OF THE WORK AND CONTRACTOR SHALL REPAIR OR REPLACE, OR CAUSE TO BE REPAIRED OR REPLACED ANY OR ALL
SUCH WORK TOGETHER WITH ANY OTHER WORK WHICH MAY BE DISPLACED IN DOING SO, THAT MAY PROVE DEFECTIVE WITHIN ONE YEAR, WITHOUT ADDITIONAL EXPENSE; ORDINARY WEAR AND TEAR, UNUSUAL ABUSE OR NEGLECT IS EXCEPTED. EXCEPTIONS
TO ONE YEAR GUARANTEE ARE SPECIFIED IN OTHER SECTIONS OF THE PROJECT MANUAL OR DRAWINGS. STATE LAW, OR MANUFACTURER'S GUARANTEE SHALL GOVERN IF LENGTH AND TYPES OF GUARANTEES ARE MORE STRICT OR FOR LONGER PERIODS. IT IS
UNDERSTOOD BY CONTRACTOR THAT IT IS HIS RESPONSIBILITY TO PROVIDE MATERIALS AND CONSTRUCTION WHICH WILL YIELD A REASONABLE VALUE OVER A PERIOD OF TIME WHICH MAY EXCEED THE SPECIFIED GUARANTEE AND WARRANTY PERIODS.
CONTRACTOR SHALL BE RESPONSIBLE FOR A WEATHER TIGHT BUILDING, FREE FROM DEFECTS OF MATERIALS AND WORKMANSHIP. EACH SUB-CONTRACTOR SHALL PROVIDE A WRITTEN GUARANTEE STATING THAT WORK EXECUTED BY HIM IS FREE AND WILL
REMAIN FREE FROM DEFECTS OF MATERIALS AND WORKMANSHIP FOR ONE YEAR FROM DATE OF ACCEPTANCE OF HIS WORK BY OWNER, AND THAT REPAIR AND REPLACEMENT OF SUCH DEFECTIVE WORK AND ALL OTHER WORK DAMAGED AS A RESULT THEREBY
WILL BE EXECUTED IN A TIMELY MANNER AT THE CONVENIENCE OF THE OWNER AND WITHOUT COST TO OWNER.
8. WAIVER OF LIENS: CONTRACTOR SHALL PROVIDE CERTIFIED RELEASE OF LIENS BY ALL SUBCONTRACTORS AND SUPPLIERS, OR ANYONE PROVIDING MATERIALS AND/OR LABOR AS THEY BECOME AVAILABLE.
9. ROLL OF ARCHITECT DURING CONSTRUCTION: THE ARCHITECT WILL NOT ACT AS THE OWNER'S REPRESENTATIVE DURING CONSTRUCTION. ARCHITECT WILL ADVISE AND CONSULT WITH OWNER. ARCHITECT WILL OBSERVE CONSTRUCTION PER HIS/HER
AGREEMENT WITH OWNER AND RENDER INTERPRETATIONS NECESSARY FOR THE PROPER EXECUTION OR PROGRESS OF THE WORK IN ACCORDANCE WITH THE INTENT OF THE PLANS AND SPECIFICATIONS. ARCHITECT WILL NOT BE RESPONSIBLE OR HAVE
CONTROL OR CHARGE OVER THE ACTS OR OMISSIONS, CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS, OF THE CONTRACTOR, SUB-CONTRACTORS, OR ANY OF THEIR AGENTS OR
EMPLOYEES, OR ANY OTHER PERSONS PERFORMING ANY OF THE WORK. ANY VERBAL INSTRUCTION OR AUTHORIZATION THAT IS CONFIRMED BY LETTER, MEETING NOTE, MEMORANDA, OR THE LIKE, (WITH A COPY SENT TO THE OWNER, OR THE OWNER'S
REPRESENTATIVE) & THERE IS NO EXCEPTION TAKEN WITHIN (10) CALENDAR DAYS, SHALL BE DEEMED EQUIVALENT TO RECEIPT OF WRITTEN INSTRUCTION, APPROVAL AND AUTHORIZATION FROM THE OWNER.
10. A.I.A. GENERAL CONDITIONS: THE CURRENT GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION PUBLISHED BY THE AMERICAN INSTITUTE OF ARCHITECTS SHALL APPLY AS THOUGH IT WERE PART OF THESE DOCUMENTS UNLESS SPECIFICALLY
MODIFIED IN THE OWNER/CONTRACTOR AGREEMENT. A COPY OF SAID GENERAL CONDITIONS MAY BE OBTAINED FROM THE ARCHITECT UPON REQUEST. THE NOTES CONTAINED IN THESE "GENERAL NOTES" ON THIS SHEET ARE INTENDED TO SUMMARIZE AND
COMPLIMENT THE A.I.A. GENERAL CONDITIONS. THE A.I.A. GENERAL CONDITIONS SHALL TAKE PRECEDENCE OVER THESE NOTES SHOULD A CONFLICT IN WORDING OCCUR.
11. EXTRAS: OWNER MAY ORDER EXTRA WORK OR MAKE CHANGES BY ALTERING, ADDING TO OR DEDUCTING FROM THE WORK, THE CONTRACT SUM BEING ADJUSTED TO THE MUTUAL SATISFACTION OF THE OWNER AND CONTRACTOR. BEFORE ANY CHANGES
ARE BEGUN, THE ADDED OR DEDUCTED SUM SHALL BE PRESENTED TO OWNER IN WRITING FOR APPROVAL.
12. SUBSTITUTIONS: SUBSTITUTIONS OF MATERIALS OR METHODS PROPOSED BY THE CONTRACTOR OR HIS SUB-CONTRACTORS CONTRARY TO DRAWINGS AND SPECIFICATIONS SHALL BE SUBMITTED TO ARCHITECT IN WRITING FOR APPROVAL OR DENIAL. IF
MORE THAN ONE MANUFACTURER IS SPECIFIED IN THE PLANS OR SPECIFICATIONS, IT SHALL BE THE CONTRACTOR'S OPTION TO SELECT THE ONE WHICH HE MAY DESIRE. IF MORE THAN ONE FINISH OR STYLE IS AVAILABLE IN THE ITEM SPECIFIED, CONTRACTOR
SHALL BE OBLIGATED TO NOTIFY ARCHITECT VERBALLY AND IN WRITING OF THIS FACT FOR ARCHITECT'S AND OWNER'S DECISION. WHERE THE TERM "OR EQUAL" IS USED IN DRAWINGS OR SPECS IT SHALL BE UNDERSTOOD THAT THE REFERENCE IS MADE
SUBJECT TO THE RULING AND JUDGMENT OF THE ARCHITECT AND SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW AND APPROVAL. ACTUAL SAMPLES OF THE SUBSTITUTIONS SHALL ALSO BE SUBMITTED TO THE ARCHITECT FOR REVIEW AND APPROVAL.
13. INSURANCE: CONTRACTOR SHALL CARRY GENERAL LIABILITY INSURANCE WITH BROAD FORM PROPERTY DAMAGE ENDORSEMENT AND CONTINGENT LIABILITY ENDORSEMENT. OWNER AND ARCHITECT SHALL BE LISTED AS ADDITIONAL INSURERS UNDER
THE POLICY WITH WAIVER OF SUBROGATION. CONTRACTOR SHALL FURNISH OWNER WITH A CERTIFICATE OF INSURANCE WITH A 30 DAY NOTICE OF CANCELLATION. OWNER SHALL OBTAIN A BUILDER'S RISK POLICY WITH ARCHITECT NAMED AS AN ADDITIONAL
INSURED WITH WAIVER OF SUBROGATION.
14. SCOPE OF DRAWINGS AND SPECIFICATIONS: THESE DRAWINGS AND SPECIFICATIONS SHALL BE INTENDED TO SHOW AND DESCRIBE DETAILS FOR A CONSTRUCTIBLE BUILDING. PARTS AND DETAILS NOT FULLY SHOWN OR DESCRIBED SHALL BE DETAILED
AND EXECUTED ACCORDING TO STANDARD FIRST CLASS PRACTICE AND IN SIMILAR MANNER AND SPIRIT OF THE DETAILS WHICH ARE SHOWN ON THE DRAWINGS AND/OR DESCRIBED IN THE PROJECT MANUAL. IF CONTRACTOR OR SUB-CONTRACTOR FINDS ANY
DETAILS WHICH, IN HIS OPINION, ARE UNSOUND, UNSAFE, OR NOT WATERPROOF, IT IS HIS DUTY TO NOTIFY ARCHITECT IN WRITING OF THIS FACT. IF WORK IS PERFORMED AS DETAILED, IT WILL BE ASSUMED THAT THERE ARE NO OBJECTIONS TO THE DETAIL.
ACCURACY OF ALL DIMENSIONS SHALL BE CHECKED. NO EXTRA COMPENSATION WILL BE ALLOWED FOR DIFFERENCE BETWEEN ACTUAL DIMENSIONS AND THOSE INDICATED ON THE DRAWINGS. IN USING THESE PLAN FOR BIDDING OR CONSTRUCTION
PURPOSES, ALL CONTRACTORS ARE REQUIRED TO REVIEW AND TREAT THEM AS A WHOLE IN ORDER TO IDENTIFY ALL REQUIREMENTS THAT DIRECTLY OR INDIRECTLY AFFECT THEIR PORTION OF THE WORK, EVEN REQUIREMENTS LOCATED IN SECTIONS
DESIGNATED AS APPLICABLE TO OTHER TRADES. IN CASE OF CONFLICTS, THE AFFECTED CONTRACTOR IS REQUIRED TO EITHER OBTAIN DIRECTION FROM AN APPROPRIATE REPRESENTATIVE OF THE OWNER, OR OTHERWISE TO APPLY THE MORE STRINGENT
STANDARD. THESE PLANS ARE INTENDED TO SET FORTH THE REQUIREMENTS FOR CONSTRUCTION IN ONLY AN INDUSTRY-STANDARD LEVEL OF QUALITY AND DETAIL, AND THEY ARE INTENDED TO BE SUPPLEMENTED BY APPROPRIATE REQUESTS FOR
CLARIFICATION AND INFORMATION. ERRORS AND OMISSIONS ARE TO BE EXPECTED AND ANTICIPATED, AND ALL CONTRACTORS ARE REQUIRED TO CAREFULLY REVIEW THESE PLANS FOR ERRORS AND OMISSIONS AND TO BRING THESE ERRORS AND OMISSIONS
TO THE ATTENTION OF A APPROPRIATE OWNER & ARCHITECT IN WRITING IN A TIMELY MANNER; AND ANY CONTRACTOR WHO FAILS TO DO SO BEFORE BIDDING OR OTHERWISE PROCEEDING ASSUMES THE RISK OF ANY CONSEQUENCES. SCALED DIMENSIONS
SHOULD BE CONSIDERED ONLY APPROXIMATE; AND IN ANY DIMENSIONS BEFORE PROCEEDING WITH ANY AFFECTED PROCUREMENT, FABRICATION OR CONSTRUCTION. SCHEMATIC PLANS ARE INTENDED ONLY TO DEMONSTRATE THE RELATIONSHIP AMONG
COMPONENT PARTS, AND NOT TO DEPICT SPECIFIC LOCATIONS (E.G. SCHEMATIC ELECTRICAL PLANS).
15. DIMENSIONS ON DRAWINGS: FIGURED DIMENSIONS SHALL BE FOLLOWED IN PREFERENCE TO SCALE, AND DETAIL DRAWINGS IN PREFERENCE TO SMALL SCALE DRAWINGS. SUB-CONTRACTOR AND CONTRACTOR SHALL CHECK ACCURACY OF ALL
DIMENSIONS IN THE FIELD PRIOR TO ANY WORK BEING CONSTRUCTED OR MATERIALS OR PRODUCTS FABRICATED OR ORDERED. SPECIFICATIONS AND WRITTEN NOTES AND SCHEDULES ON DRAWINGS SHALL BE FOLLOWED IN PREFERENCE TO INFORMATION
FURNISHED IN THE FORM OF LINE DRAWINGS. DETAILED DRAWINGS FURNISHED DURING CONSTRUCTION OR APPROVED BY CONTRACTOR OR ARCHITECT ARE TO BE CONSIDERED EXPLANATORY AND NOT AS CHANGES TO DRAWINGS AND SPECIFICATIONS.
NOTES, FIGURES AND DETAILS ON SAID DRAWINGS SHALL BE FOLLOWED AND EXECUTED AS IF PART OF THESE DOCUMENTS. DRAWINGS ARE NOT TO BE SCALED UNLESS PERMITTED BY THE ARCHITECT. DIMENSIONS SHALL GOVERN. ALL EXTERIOR
DIMENSIONS ARE BASED ON NOMINAL SIZES OF MEMBERS AND ARE GIVEN TO THE OUTER FACE OF SUCH MEMBERS, UNLESS OTHERWISE NOTED ON DRAWINGS. INTERIOR PARTITIONS ARE DIMENSIONED FROM FACE OF STRUCTURE TO FACE OF STRUCTURE
UNLESS OTHERWISE NOTED ON DRAWINGS. WHERE DIMENSION IS LABELED "CLEAR" IT IS TAKEN FROM THE FACE OF FINISH TO FACE OF FINISH OF EACH MATERIAL. PLUS OR MINUS (+/-) DIMENSIONS SHALL NOT VARY BY MORE THAN 2" WITHOUT APPROVAL
BY ARCHITECT. WALL ANGLES ARE EITHER 90° OR 45° UNLESS NOTED OTHERWISE.
16. SUBMITTALS, MEETING NOTES, BULLETINS, AND MEMOS: SUBMITTALS WILL BE REVIEWED BY THE ARCHITECT, IF AT ALL, ONLY PURSUANT TO THE INDUSTRY-STANDARD PROTOCOL SET FORTH IN AIA DOCUMENT A201-2017; AND IN NO EVENT WILL THE
SUBMITTAL REVIEW PROCESS RELIEVE OR LESSEN THE SUBMITTING CONTRACTOR'S RESPONSIBILITY FOR AN INAPPROPRIATE SUBMITTAL. ARCHITECT, FROM TIME TO TIME, WILL ISSUE CONSTRUCTION NOTES OR MEMOS REGARDING CONSTRUCTION ISSUES
THAT HAVE ARISEN SINCE THE DRAWINGS AND SPECIFICATIONS WERE COMPLETED. CONTRACTOR SHALL REVIEW THESE WRITTEN DOCUMENTS AND INCORPORATE THEM INTO THE PROJECT. ANY QUESTIONS OR OBJECTIONS AS TO THE INTENT OF THE WRITTEN
DOCUMENT ITEMS WILL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT FOR DISCUSSION AND OR CLARIFICATION. ANY ITEM THAT RESULTS IN A CHANGE TO THE COST OR TIMING OF THE PROJECT SHALL BE BROUGHT TO THE IMMEDIATE
ATTENTION OF THE OWNER & ARCHITECT PRIOR TO EXECUTING. CONTRACTOR SHALL SUBMIT FABRICATION SHOP DRAWINGS TO THE ARCHITECT FOR APPROVAL PRIOR TO ORDERING AND/OR FABRICATION. CONTRACTOR SHALL SUBMIT MANUFACTURER'S CUTS
FOR ALL FIXTURES AND EQUIPMENT CALLED FOR ON THE CONSTRUCTION DOCUMENTS TO ARCHITECT INCLUDING BUT NOT LIMITED TO LIGHT FIXTURES, HARDWARE, PLUMBING FIXTURES, KITCHEN EQUIPMENT, ETC. BY SUBMITTING SHOP DRAWINGS AND
PRODUCT DATA, THE CONTRACTOR REPRESENTS THAT HE/SHE HAS VERIFIED FIELD CONDITIONS, DIMENSIONS AND RELATED CONSTRUCTION AND HAS COORDINATED THE SUBMISSION CONSTRUCTION WITH THE REQUIREMENTS OF ALL OTHER RELATED WORK IN
THE CONSTRUCTION DOCUMENTS. ALL SHOP DRAWINGS AND CUTS MARKED "REVIEWED" BY ARCHITECT, ARE FOR VERIFICATION OF ADHERENCE TO THE DESIGN INTENT ONLY. THE CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR ALL MEANS AND METHODS
AND ERRORS AND OMISSIONS ON THEIR DRAWINGS. CONTRACTOR TO SUBMIT A COMPLETE SHOP DRAWINGS AND OR SUBMITTAL FOR APPROVAL BEFORE COMMENCING FABRICATION AND/OR INSTALLATION OF ALL APPLICABLE ITEMS. ALL SHOP DRAWINGS
DIMENSIONS SHALL BE FIELD VERIFIED, REVIEWED AND APPROVED BY CONTRACTOR BEFORE SUBMITTAL. SHOP DRAWINGS WHICH ARE INCOMPLETE OR LACKING SUFFICIENT INFORMATION WILL BE RETURNED WITHOUT REVIEW. SUBMIT SAMPLES FOR INITIAL
SELECTION PURPOSES OF ACTUAL VENEERS SHOWING A FULL RANGE OR GRAIN VARIATION, FINISH AND PATTERNS PROPOSED. SUBMIT SAMPLES AS REQUIRED UNTIL APPROVED BY ARCHITECT. SAMPLES SHALL BE 12" X 12" MIN., ONE UNIT OF EACH TYPE
AND FINISH.
17. ERRORS AND OMISSIONS: ERRORS OR OMISSIONS WHICH APPEAR ON THE DRAWINGS, IN SPECIFICATIONS OR OTHER CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT BY THE CONTRACTOR AND TO THE
CONTRACTOR BY THE SUB-CONTRACTOR IN WRITING. IN EVENT OF FAILURE OF SUB-CONTRACTOR TO GIVE SUCH WRITTEN NOTIFICATION BEFORE CONSTRUCTION OR FABRICATIONS OF THE WORK, HE WILL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY SUCH
ERRORS OR OMISSIONS AND THE COSTS OF RECTIFYING SAME. HOWEVER, DRAWINGS AND SPECIFICATIONS ARE COMPLEMENTARY AND WORK CALLED FOR ON ONE AND NOT THE OTHER SHALL BE PROVIDED AS THOUGH FULLY SET FORTH IN BOTH.
18. BARRICADES: CONTRACTOR SHALL ERECT AND PROPERLY MAINTAIN AT ALL TIMES AS REQUIRED BY CONDITIONS AND PROGRESS OF THE WORK, ALL NECESSARY PROTECTIVE BARRICADES, FENCES AND OTHER SAFEGUARDS FOR THE PROTECTION OF THE
WORKERS AND THE PUBLIC. THESE BARRICADES SHALL BE CONSTRUCTED AND BE LOCATED AS SHALL BE DETERMINED BY LOCAL AUTHORITIES AND CODES.
19. TEMPORARY BRACING: AT ALL TIMES DURING CONSTRUCTION ACTIVITIES OR ERECTION OF PROJECT OR ITS COMPONENT PARTS, PRIOR TO COMPLETION OF THE STRUCTURAL FRAME OR REPLACEMENT AND PERMANENT CONNECTION OF COMPONENT
MEMBERS TO THE STRUCTURAL FRAME, SUB-CONTRACTORS SHALL PROVIDE, INSTALL AND MAINTAIN PROPERLY DESIGNED AND CONSTRUCTED TEMPORARY BRACING OF ADEQUATE STRENGTH TO PREVENT DISLOCATION, DISTORTION, CRACKING, FALLING OFF,
OR ANY OTHER DAMAGE TO WORK OR ANY OF ITS COMPONENT PARTS DUE TO FORESEEABLE NORMAL AS WELL AS NOT FORESEEABLE EXCESSIVE WIND AND EARTHQUAKE FORCES WITHOUT ADDITIONAL COST TO OWNER. CONTRACTOR AND HIS
SUBCONTRACTORS SHALL, AT THEIR EXPENSE, REPLACE OR REPAIR, AS DIRECTED, DAMAGED PORTIONS OF THEIR WORK OR COMPONENT PARTS.
20. TOXIC SUBSTANCES REMOVAL: PRIOR TO ANY WORK BEING PERFORMED, WHENEVER THERE ARE EXISTING STRUCTURES TO BE REMOVED OR ALTERED, CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION AND REMOVAL OF ANY TOXIC MATERIALS OR
SUBSTANCES AS REQUIRED BY THE STATE OF CALIFORNIA INCLUDING BUT NOT LIMITED TO ASBESTOS, LEAD PAINTS, MOLD, ETC. REMOVAL AND DISPOSAL SHALL FOLLOW STATE MANDATED METHODS, PROCEDURES, DOCUMENTATION AND APPLICATION
REQUIREMENTS.
21. NO CHANGES ARE TO BE MADE ON THESE PLANS WITHOUT THE KNOWLEDGE OR CONSENT OF THE ARCHITECT/ ENGINEER WHOSE SIGNATURE APPEARS HERON.
22. NO FRAMING OF ANY TYPE TO BE CONCEALED PRIOR TO INSPECTION BY GOVERNING AGENCIES.
23. REFERENCES TO ANY DETAIL OR DRAWINGS IS FOR CONVENIENCE ONLY AND DOES NOT LIMIT THE APPLICATION OF SUCH DETAIL OR DRAWINGS.
24. USE 2X6 MINIMUM STUDS FOR PLUMBING WALLS
25. MAINTENANCE INFORMATION: THE BUILDER SHALL PROVIDE TO THE BUILDING OWNER AT OCCUPANCY MAINTENANCE INFORMATION FOR ALL FEATURES, MATERIALS, COMPONENTS, AND MANUFACTURED INFORMATION FOR ALL FEATURES, MATERIALS, AND
COMPONENTS AND MANUFACTURED DEVICES THAT REQUIRE ROUTINE MAINTENANCE FOR EFFICIENT OPERATION. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY STATED AND INCORPORATED ON A READILY ACCESSIBLE LABEL. THE LABEL MAY
BE LIMITED TO IDENTIFYING, BY TITLE AND/OR PUBLICATION NUMBER, THE OPERATION AND MAINTENANCE MANUAL FOR THAT PARTICULAR MODEL AND TYPE OF FEATURE, MATERIAL, COMPONENT, OR MANUFACTURED DEVICE. (SEE CALGREEN NOTES FOR
ADDITIONAL REQUIREMENTS OF OPERATION & MAINTENANCE MANUAL)
26. GENERAL CONTRACTOR, CONTRACTORS, SUB-CONTRACTORS AND BUILDERS TO COORDINATE ALL ENGINEERING AND MECHANICAL DRAWINGS WITH ARCHITECTURAL DRAWINGS BEFORE PROCEEDING WITH WORK. IF DISCREPANCIES ARE APPARENTLY
OBSERVED OR INFORMATION APPARENTLY IS THOUGHT TO BE MISSING, NOTIFY ARCHITECT WITHIN 24 HOURS WITH SKETCH, DRAWING, PDF, PHOTOCOPIES WITH LEGIBLE HANDWRITTEN NOTES AND/OR WRITING (FAX, EMAIL OR CORRESPONDENCE). IF CONFLICT
WITH EXISTING CONDITIONS, PROVIDE DOCUMENTATION (PHOTOS, SKETCHES, DWGS) OF EXISTING CONDITIONS AND SUGGEST PROPOSAL(S) FOR SOLUTION (SKETCH, DRAWING, AND/OR WRITING). IN CASE OF ANY DISCREPANCIES, THE ARCHITECT IS THE SOLE
INTERPRETER OF THE CONTRACT DOCUMENTS.
27. CONTRACTOR SHALL NOTIFY ARCHITECT FOR CLARIFICATION PRIOR TO BIDDING OF ANY DISCREPANCIES BETWEEN ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS. BID SHALL BE BASED ON THE MOST STRINGENT REQUIREMENT.
28. CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT OF ANY UNEXPECTED OR UNKNOWN FIELD CONDITIONS, ERRORS, OMISSIONS, OR DISCREPANCIES IN THE DRAWINGS, PROJECT MANUAL, OR CONTRACT DOCUMENTS PRIOR TO PROCEEDING WITH
THE WORK OR SHOP FABRICATIONS.
29. CONTRACTOR SHALL PREPARE AND MAINTAIN ALL CONSTRUCTION, AND SURROUNDING AREAS, FREE OF DEBRIS OR HAZARDOUS MATERIALS AT ALL TIMES. CONTRACTOR SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT DUST FROM RISING.
30. CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR AND/OR THE REPLACEMENT OF ANY ITEMS DAMAGED DURING CONSTRUCTION OR CLEAN-UP. ANY DAMAGE TO EXISTING STRUCTURES DURING THE CONSTRUCTION OR THE NEW WORK SHALL BE
REPAIRED TO EQUIVALENT OR BETTER THAN ORIGINAL CONDITION AT CONTRACTOR'S EXPENSE.
31. ALL OSHA REGULATIONS FOR CONSTRUCTION AREAS SHALL BE STRICTLY FOLLOWED. CONTRACTOR SHALL PROVIDE PROPER SAFEGUARDS DURING ALL PHASES OF CONSTRUCTION.
32. CONTRACTOR TO REMOVE, RELOCATE OR RE-ROUTE, AS NECESSARY, ELECTRICAL, TELEPHONE, WATER, SEWER, GAS OR ANY OTHER UTILITY LINES ENCOUNTERED AND SHALL COORDINATE THIS WORK WILL ALL LOCAL UTILITY COMPANIES.
33. CONTRACTOR SHALL PROVIDE TEMPORARY WEATHER PROTECTION FOR PORTIONS OF THE WORK THAT BECOME EXPOSED TO WEATHER AND SHALL BE RESPONSIBLE FOR DAMAGE CAUSED BY INSUFFICIENT PROTECTION.
34. CONTRACTOR TO OBTAIN WRITTEN APPROVAL FROM OWNER AND ARCHITECT PRIOR TO ANY CHANGES OR DEVIATION FROM CONTRACT DOCUMENTS.
35. CONTRACTOR SHALL SUBMIT IN WRITING ALL PROPOSALS FOR ADDITIONAL WORK TO THE OWNER FOR REVIEW AND APPROVAL. NO WORK IS TO PROCEED UNTIL AN AUTHORIZATION TO PROCEED; SIGNED BY THE ARCHITECT & OWNER'S REPRESENTATIVE IS
RETURNED TO THE GENERAL CONTRACTOR.
36. CONTRACTOR SHALL BE AWARE THAT SPECIFIC FIRE-RATED SEPARATION WITHIN THE BUILDING'S CONSTRUCTION IS REQUIRED BY CODE. THE USE OF SPECIFIC MATERIALS AND COMBINATION OF MATERIALS WITHIN FIRE RATED ASSEMBLIES, AS CALLED
FOR ON THE DRAWINGS AND SPECIFICATIONS, ARE FOR THE PURPOSE OF ACHIEVING THOSE REQUIRED FIRE SEPARATIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THAT ANY CHANGE IN MATERIAL THAT IS REQUESTED BY OR MADE BY THE
CONTRACTOR AND/OR ITS SUBCONTRACTORS, FROM THOSE MATERIALS DRAWN OR SPECIFIED, DOES NOT IN ANY WAY AFFECT OR LESSEN THE REQUIRED CONSTRUCTION ASSEMBLY INTEGRITY. SPECIFIC SEQUENCES OR METHODS OF ACHIEVING FIRE RATED
ASSEMBLIES REQUIRED BY A "U.L. NO." LISTING SHALL BE FOLLOWED WITHOUT DEVIATION, UNLESS OTHERWISE NOTED OR DETAILED.
69. CONTRACTOR TO FURNISH AND INSTALL ALL BLOCKING REQUIRED FOR WALL MOUNTED OR BRACED FIXTURES, MILLWORK, SHELVES, TOILET FIXTURES, AND ACCESSORIES OR 'BY OTHER' ITEMS DESCRIBED IN INTERIOR DESIGN AND ARCHITECTURAL
DRAWINGS. BLOCKING SHALL BE CONSTRUCTED TO SUPPORT THE IMPOSED LOAD.
37. ALL MANUFACTURED ARTICLES, MATERIALS AND EQUIPMENT SHALL BE SUPPLIED, INSTALLED, CONNECTED, ERECTED, USED, CLEANED AND CONDITIONED AS DIRECTED BY THE MANUFACTURERS AND REQUIRED BY CODE.
38. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY/COORDINATE UTILITY REQUIREMENTS FOR ALL OWNER/VENDOR FURNISHED EQUIPMENT, FIXTURES OR APPLIANCES.
39. CONTRACTOR SHALL PROVIDE ALL NECESSARY FASTENERS, SUPPORTS, SHIMMING, FLASH PATCHING, ETC. FOR THE PROPER INSTALLATION OF SUCH ITEMS AS DIRECTED BY THE MANUFACTURERS.
40. UPON COMPLETION OF THE PROJECT, THE CONTRACTOR SHALL GIVE TO THE OWNER A COMPLETE SET OF AS-BUILT CIVIL, LANDSCAPE, ARCHITECTURAL, MECHANICAL, PLUMBING, ELECTRICAL AND FIRE PROTECTION DRAWINGS ALONG WITH THE WRITTEN
GUARANTIES, OPERATION AND MAINTENANCE MANUALS OF ALL EQUIPMENT AND FINISHES INSTALLED. THE CONTRACTOR SHALL MAINTAIN A CURRENT SET OF AS-BUILT DRAWINGS AND SPECIFICATIONS. INFORMATION SHALL BE RECORDED BY CONTRACTOR
AS CONSTRUCTION PROGRESSES AND REVIEWED FOR COMPLETENESS AT EACH REQUISITION REQUEST.
41. CONTRACTOR IS RESPONSIBLE TO THOROUGHLY VACUUM CLEAN ALL CARPETED AREAS, CLEAN ALL FLOORING, MILLWORK, LIGHT FIXTURES, GLASS, ETC. AND UNCOVER AND VACUUM OUT ALL MECHANICAL UNITES AFTER THE WORK IS COMPLETED AND
MAINTAIN CLEAN CONDITIONS THROUGH THE TENANT'S MOVE-IN.
WATERPROOFING AND DAMPPROOFING NOTES:
R406.1 CONCRETE AND MASONRY FOUNDATION DAMPPROOFING
EXCEPT WHERE REQUIRED BY SECTION R406.2 TO BE WATERPROOFED, FOUNDATION WALLS THAT RETAIN EARTH AND
ENCLOSE INTERIOR SPACES AND FLOORS BELOW GRADE SHALL BE DAMPPROOFED FROM THE HIGHER OF (A) THE TOP OF THE
FOOTING OR (B) 6 INCHES (152 MM) BELOW THE TOP OF THE BASEMENT FLOOR, TO THE FINISHED GRADE. MASONRY WALLS
SHALL HAVE NOT LESS THAN 3/8-INCH (9.5 MM) PORTLAND CEMENT PARGING APPLIED TO THE EXTERIOR OF THE WALL. THE
PARGING SHALL BE DAMPPROOFED IN ACCORDANCE WITH ONE OF THE FOLLOWING:
1. BITUMINOUS COATING.
2. THREE POUNDS PER SQUARE YARD (1.63 KG/M2) OF ACRYLIC MODIFIED CEMENT.
3. ONE-EIGHTH-INCH (3.2 MM) COAT OF SURFACE-BONDING CEMENT COMPLYING WITH ASTM C887.
4. ANY MATERIAL PERMITTED FOR WATERPROOFING IN SECTION R406.2.
5. OTHER APPROVED METHODS OR MATERIALS.
EXCEPTION:PARGING OF UNIT MASONRY WALLS IS NOT REQUIRED WHERE A MATERIAL IS APPROVED FOR DIRECT
APPLICATION TO THE MASONRY.CONCRETE WALLS SHALL BE DAMPPROOFED BY APPLYING ANY ONE OF THE LISTED
DAMPPROOFING MATERIALS OR ANY ONE OF THE WATERPROOFING MATERIALS LISTED IN SECTION R406.2 TO THE EXTERIOR
OF THE WALL.
R406.2 CONCRETE AND MASONRY FOUNDATION WATERPROOFING
IN AREAS WHERE A HIGH WATER TABLE OR OTHER SEVERE SOIL-WATER CONDITIONS ARE KNOWN TO EXIST, EXTERIOR
FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE INTERIOR SPACES AND FLOORS BELOW GRADE SHALL BE
WATERPROOFED FROM THE HIGHER OF (A) THE TOP OF THE FOOTING OR (B) 6 INCHES (152 MM) BELOW THE TOP OF THE
BASEMENT FLOOR, TO THE FINISHED GRADE. WALLS SHALL BE WATERPROOFED IN ACCORDANCE WITH ONE OF THE
FOLLOWING:
1. TWO-PLY HOT-MOPPED FELTS.
2. FIFTY-FIVE-POUND (25 KG) ROLL ROOFING.
3. SIX-MIL (0.15 MM) POLYVINYL CHLORIDE.
4. SIX-MIL (0.15 MM) POLYETHYLENE.
5. FORTY-MIL (1 MM) POLYMER-MODIFIED ASPHALT.
6. SIXTY-MIL (1.5 MM) FLEXIBLE POLYMER CEMENT.
7. ONE-EIGHTH-INCH (3 MM) CEMENT-BASED, FIBER-REINFORCED, WATERPROOF COATING.
8. SIXTY-MIL (1.5 MM) SOLVENT-FREE LIQUID-APPLIED SYNTHETIC RUBBER.
ALL JOINTS IN MEMBRANE WATERPROOFING SHALL BE LAPPED AND SEALED WITH AN ADHESIVE COMPATIBLE WITH THE
MEMBRANE.
EXCEPTION: ORGANIC-SOLVENT-BASED PRODUCTS SUCH AS HYDROCARBONS, CHLORINATED HYDROCARBONS, KETONES AND
ESTERS SHALL NOT BE USED FOR ICF WALLS WITH EXPANDED POLYSTYRENE FORM MATERIAL. USE OF PLASTIC ROOFING
CEMENTS, ACRYLIC COATINGS, LATEX COATINGS, MORTARS AND PARGINGS TO SEAL ICF WALLS IS PERMITTED. COLD-SETTING
ASPHALT OR HOT ASPHALT SHALL CONFORM TO TYPE C OF ASTM D449. HOT ASPHALT SHALL BE APPLIED AT A TEMPERATURE
OF LESS THAN 200°F (93°C).
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE
NEAREST 1/8" AND INTERIOR PARTITIONS ARE DIMENSIONED FROM FACE OF STRUCTURE TO FACE OF STRUCTURE (F.O.S.)
U.N.O. -CONTACT ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
ROUGH FRAMING:
ALL EXTERIOR WALLS TO BE FRAMED W/. 2X6 STUD MIN. U.N.O.
USE 2X6 MINIMUM STUDS FOR PLUMBING WALLS
SECOND AND THIRD FLOOR PLYWOOD TO BE 1-1/8"
ENTIRE EXTERIOR TO BE SHEATHED WITH 1/2" PLYWOOD
DOORS AND WINDOWS WILL TYPICALLY BE RECESSED FROM EXTERIOR WALL PLANE. VERIFY ALL ROUGH OPENING
DIMENSIONS WITH DOOR AND WINDOW MFGR. ROUGH OPENING MAY NEED TO BE OVERSIZED TO ACCOUNT FOR ADDITIONAL
FRAMING. SEE SHT. AD-2.0 FOR TYP. RECESSED CONDITIONS.
DUCTS PENETRATION:
DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE
SHALL BE CONSTRUCTED OF A MINIMUM NO. 26 GAGE (0.48 MM) SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL
NOT HAVE OPENINGS INTO THE GARAGE (R302.5.2)
STAIRWAY ILLUMINATION:
1.INTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE TO ILLUMINATE THE LANDINGS AND TREADS.
THE LIGHT SOURCE SHALL BE CAPABLE OF ILLUMINATING TREADS AND LANDINGS TO LEVELS OF NOT LESS THAN 1 FOOT-
CANDLE (11 LUX) AS MEASURED AT THE CENTER OF TREADS AND LANDINGS. THERE SHALL BE A WALL SWITCH AT EACH
FLOOR LEVEL TO CONTROL THE LIGHT SOURCE WHERE THE STAIRWAY HAS SIX OR MORE RISERS. (R303.7)
EXCEPTION:A SWITCH IS NOT REQUIRED WHERE REMOTE, CENTRAL OR AUTOMATIC CONTROL OF LIGHTING IS
PROVIDED.
2.EXTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE TOP LANDING OF THE
STAIRWAY. EXTERIOR STAIRWAYS PROVIDING ACCESS TO A BASEMENT FROM THE OUTDOOR GRADE LEVEL SHALL BE
PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE BOTTOM LANDING OF THE STAIRWAY. (R303.8)
GARAGE FLOOR:
GARAGE FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTIBLE MATERIAL.THE AREA OF FLOOR USED FOR PARKING OF
AUTOMOBILES OR OTHER VEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS TO A DRAIN OR TOWARD
THE MAIN VEHICLE ENTRY DOORWAY. (R309.1)
PLUMBING:
1. ALL FIXTURES AND FITTINGS SHALL COMPLY WITH THE MAX FLOW RATE SET BY CALGREEN (CALIFORNIA GREEN BUILDING
STANDARD CODE) AND CALIFORNIA PLUMBING CODES. G.C. TO VERIFY PRIOR TO PURCHASE AND INSTALL OF ANY FIXTURE
AND FITTING
2. MAX. TEMP. OF 120° TO BE APPROVED BY THE USE OF PRESSURE BALANCE OR THERMOSTATIC MIXING VALVES TYP. IN
COMPLIANCE W/. ASSE 1070/ASME A112.1070/CSA B125.70 @ SHOWERS & TUBS.
3. MAX. TEMP. OF 110° TO BE APPROVED BY THE USE OF PRESSURE BALANCE OR THERMOSTATIC MIXING VALVES TYP. IN
COMPLIANCE W/. ASSE 1070/ASME A112.1070/CSA B125.70 @ BIDETS.
4. SUPPORT ALL WALL-HUNG FIXTURES WITH METAL SUPPORTING MEMBERS TO PREVENT ANY STRAIN TRANSMISSION TO
THE CONNECTIONS. FRAMING AFFIXED SUPPORTS FOR OFF-THE-FLOOR WATER CLOSETS WITH CONCEALED TANKS SHALL
COMPLY WITH ASME A112.6.2. SECURE FLUSH TANK AND SIMILAR APPURTENANCES WITH APPROVED NON-CORROSIVE SCREW
OR BOLTS. (CPC 402.5)
5. THE NET AREA OF THE SHOWER ENCLOSURE SHALL BE 1,024 SQ. INCHES (7.1 SQ. FT.) OR MORE IN THE CLEAR FLOOR AREA,
AND SHALL ALSO BE CAPABLE OF ENCOMPASSING A 30-INCH DIAMETER CIRCLE. (CPC 408.6)
6. THE WATER HEATER BURNER AND BURNER-IGNITION DEVICE TO BE AT LEAST 18-INCHES ABOVE THE FLOOR, IF LOCATED IN A
GARAGE AND IN ADJACENT SPACES THAT OPEN TO THE GARAGE. FOR WATER HEATER IN THE GARAGE OR OTHER AREAS
SUBJECT TO MECHANICAL DAMAGE PROVIDE A PROTECTIVE BARRIER OR ELEVATE THE APPLIANCE TO BE OUT OF THE NORMAL
PATH OF THE VEHICLE. (CPC 507.13)
7. ANCHOR OR STRAP THE WATER HEATER(S) TO RESIST HORIZ. DISPLACEMENT DUE TO THE EARTHQUAKE. STRAPPING
SHOULD BE AT THE UPPER AND LOWER ONE THIRD (1/3) POINTS OF THE APPLIANCE HEIGHT. MAINTAIN A MIN. 4-INCHES
ABOVE THE CONTROLS WITH STRAPPING AT LOWER POINT.
MATERIALS & FINISHES:
1. WALLS COVERINGS AND FLOOR OF SHOWERS AND BATHTUBS WITH A SHOWER HEAD SHALL BE OF CEMENT PLASTER, TILE,
OR APPROVED EQUAL NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS THAN 72-INCHES ABOVE THE FLOOR. PROVIDE
CEMENT BOARD, CEMENT PLASTER BACKING, OR TILE BACKBOARD FOR TILE FINISH. (CRC R307.2)
2. INSTALL MIN. 5/8" TYPE 'X' MOISTURE & MOLD RESISTANT GYPSUM WALL BOARD IN ALL BATHROOMS AND KITCHENS.
FIREPLACES:
1. FACTORY-BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR COMPONENTS SHALL BE LISTED AND INSTALLED IN
ACCORDANCE WITH THEIR LISTING AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. (CRC R1004.1)
2. FACTORY BUILT WOOD BURNING FIREPLACES SHALL BE QUALIFIED AT THE U.S. EPA’S VOLUNTARY FIREPLACE PROGRAM
PHASE 2 EMISSIONS LEVEL. (CRC 1004.1.1)
3. DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT THE TERMINATION OF FACTORY-BUILT CHIMNEYS EXCEPT WHERE
SUCH SHROUDS ARE LISTED AND LABELED FOR USE WITH THE SPECIFIC FACTORY-BUILT CHIMNEY SYSTEM AND ARE
INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. (CRC R1005.2 & CMC 802.5.1.1 & CMC
802.5.4.3)
4. HORIZONTAL OPENINGS ARE NOT ALLOWED, FOR EXHAUST VENTS, IN WALLS CLOSER THAN 3 FEET TO A PROPERTY LINE.
(TABLES R302.1(1)&(2)). HORIZONTAL VENT CAPS SHALL BE 2 FEET CLEAR FROM PROPERTY LINES.
5. EXHAUST OPENINGS SHALL NOT BE DIRECTED ONTO WALKWAYS. (R303.5.2)
6. SOLID FUEL BURNING FIREPLACES (IF PERMISSIBLE):
A. PROVIDE A PERMANENTLY ANCHORED GASEOUS FUEL BURNING PAN TO THE FIREBOX OF A SOLID
FUEL BURNING FIREPLACE.
B. SOLID FUEL BURNING FIREPLACE MUST COMPLY WITH THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES.
C. CHIMNEY SHALL EXTEND AT LEAST 2 FT. HIGHER THAN ANY PORTION OF THE BUILDING WITHIN 10 FT., BUT SHALL
NOT BE LESS THAN 3 FT. ABOVE THE HIGHEST POINT WHERE THE CHIMNEY PASSES THROUGH THE ROOF. (CRC R1003.9)
D. LIQUID FUELED FIREPLACES ARE NOT ALLOWED FOR INTERIOR USE.
7. ANY INSTALLED GAS FIREPLACE SHALL BE DIRECT VENT SEALED-COMBUSTION PER CAL GREEN SECTION 4.503.
POOL:
1. PROVIDE AN ALARM FOR DOORS AND WINDOWS WITH SILL HEIGHTS LESS THAN 60-INCHES ABV.F.F. OF THE DWELLING THAT
FORMS A PART OF THE POOL ENCLOSURE. THE ALARM SHALL BE LISTED AS A WATER HAZARD ENTRANCE ALARM IN
ACCORDANCE WITH UL 2017. THE DEACTIVATION SWITCH SHALL BE AT LEAST 60" ABOVE THE FLOOR IF THE RESIDENCE IS NOT
REQUIRED TO BE ACCESSIBLE. (CBC 3109 & ISPSC 305.4)
2. SUCTION OUTLETS SHALL BE DESIGNED AND INSTALLED WITH SUCTION ANTIENTRAPMENT GRATE IN ACCORDANCE WITH
ANSI/APSP-16 PER CBC 3109 SECTION (B) OF 115928. SUCTION ENTRAPMENT AVOIDANCE FOR POOL AND SPA SHALL BE
PROVIDED IN ACCORDANCE WITH APSP-7 PER ISPSC SECTION 310.
3. PROVIDE POWER SAFETY COVER IN COMPLIANCE WITH ASTM F1346-91 FOR POOL & SPA (CBC 3109 SECTION (3) OF 115922
& ISPSC 305).
4. POOL ENCLOSURE FENCE SHALL BE 60-INCHES MIN. ABV. FS/NG MEASURED ON THE SIDE THAT FACES AWAY FROM
SWIMMING POOL W/. MAX VERTICAL CLEARANCE OF 2-INCHES BETWEEN FS/NG AND BOTTOM OF THE FENCE/BARRIER
MEASURED ON THE SIDE OF FENCE THAT FACES AWAY FROM SWIMMING POOL. OPENING, GAP, AND VOID IN ENCLOSURE
FENCE OR GATE SHALL NOT ALLOW THE PASSAGE OF 4-INCHES DIAMETER SPHERE OR LARGER. OUTSIDE SURFACE (FACING
AWAY FROM SWIMMING POOL) OF THE POOL ENCLOSURE INCLUDING THE GATE TO BE FREE OF PROTRUSIONS, CAVITIES, OR
OTHER PHYSICAL CHARACTERISTICS THAT WOULD SERVE AS HANDHOLDS OR FOOTHOLDS WHICH COULD ENABLE A CHILD FIVE
YEARS OLD OR YOUNGER TO CLIMB OVER. (CBC 3109 & ISPSC 305)
WOOD OR WOODBASED PRODUCTS NOTE:
WOOD OR WOODBASE PRODUCT SHALL BE OF A NATURAL DURABLE OR PRESERVATIVE-TREADED WOOD IN ACCORDANCE WITH
AWPA U1 FOR THE SPECIES, PRODUCT, PRESERVATIVE AND END USE IN THE FOLLOWING LOCATIONS:
1. WOOD JOISTS OR THE BOTTOM OF A WOOD STRUCTURAL FLOOR WHEN CLOSER THAN 18 INCHES (457 MM) OR WOOD
GIRDERS WHEN CLOSER THAN 12 INCHES (305 MM) TO THE EXPOSED GROUND IN CRAWL SPACES OR UNEXCAVATED AREA
LOCATED WITHIN THE PERIPHERY OF THE BUILDING FOUNDATION.
2. WOOD FRAMING MEMBERS THAT REST ON CONCRETE OR MASONRY EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8
INCHES (203 MM) FROM THE EXPOSED GROUND.
3. SILLS AND SLEEPERS ON A CONCRETE OR MASONRY SLAB THAT IS IN DIRECT CONTACT WITH THE GROUND UNLESS
SEPARATED FROM SUCH SLAB BY AN IMPERVIOUS MOISTURE BARRIER.
4. THE ENDS OF WOOD GIRDERS ENTERING EXTERIOR MASONRY OR CONCRETE WALLS HAVING CLEARANCES OF LESS THAN
1/2 INCH (12.7 MM) ON TOPS, SIDES AND ENDS.
5. WOOD SIDING, SHEATHING AND WALL FRAMING ON THE EXTERIOR OF A BUILDING HAVING A CLEARANCE OF LESS THAN 6
INCHES (152 MM) FROM THE GROUND OR LESS THAN 2 INCHES (51 MM) MEASURED VERTICALLY FROM CONCRETE STEPS,
PORCH SLABS, PATIO SLABS AND SIMILAR HORIZONTAL SURFACES EXPOSED TO THE WEATHER.
6. WOOD STRUCTURAL MEMBERS SUPPORTING MOISTURE-PERMEABLE FLOORS OR ROOFS THAT ARE EXPOSED TO THE
WEATHER, SUCH AS CONCRETE OR MASONRY SLABS, UNLESS SEPARATED FROM SUCH FLOORS OR ROOFS BY AN IMPERVIOUS
MOISTURE BARRIER.
7. WOOD FURRING STRIPS OR OTHER WOOD FRAMING MEMBERS ATTACHED DIRECTLY TO THE INTERIOR OF EXTERIOR
MASONRY WALLS OR CONCRETE WALLS BELOW GRADE EXCEPT WHERE AN APPROVED VAPOR RETARDER IS APPLIED BETWEEN
THE WALL AND THE FURRING STRIPS OR FRAMING MEMBERS.
WASHER & DRYER NOTE:
AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –PROVIDE POWER , GAS, WATER SUPPLY & DRAINAGE AS REQUIRED -THE
CLOTHES DRYERS VENT SHALL BE OF A RIGID METALLIC MATERIAL AND HAVE A BACKDRAFT DAMPER (CMC 504.4) AND SHALL
NOT EXCEED 14-FEET IN OVERALL LENGTH WITH MAX. OF TWO (2) 90-DEGREE ELBOW, SUBTRACT 2-FEET FOR EACH
ADDITIONAL 90-DEGREE ELBOW. (CMC 504.4.2.1) DRYER VENT TERMINATION MUST BE 3-FEET FROM OPENINGS INTO THE
BUILDING (DOORS AND OPERABLE WINDOWS), 10-FEET FROM FORCED AIR INLET, AND 3-FEET FROM PROPERTY LINE (NOT TO
DISCHARGE ONTO A PUBLIC WALKWAY). (CMC 502.2.1) IF DRYER LOCATED IN A CLOSET PROVIDE A MIN. 100 SQ.IN. OPENING
IN THE CLOSET DOOR. (CMC. 504.4.1)
*HERS VERIFICATION REQUIRED-REFERENCE T-24.1
&AND
.ANGLE
@ AT
C.L. CENTERLINE
∅DIAMETER, ROUND
.PERPENDICULAR
# POUND OR NUMBER
A.B.ANCHOR BOLT
ABV. ABOVE
A/C.AIR CONDITIONING
A.C.ASPHALT CONCRETE
ACOUS ACOUSTICAL
A.D.AREA DRAIN
ADH. ADHESIVE
ADJ. ADJUSTABLE, ADJACENT
AL.ALUMINUM
ALT.ALTERNATE
ANOD.ANODIZED
A.P.ACCESS PANEL
APPX. APPROXIMATE
APPV'D. APPROVED
ARCH.ARCHITECTURAL,ARCHITECT
ASB. ASBESTOS
ASSY. ASSEMBLY
AUTO.AUTOMATIC
B. BATHROOM
BD. BOARD
BEL. BELOW
BET. BETWEEN
BIT. BITUMINOUS
BLDG.BUILDING
BLK. BLOCK
BLK'G.BLOCKING
BM. BEAM
B.O.BY OWNER, BY OTHERS
BOT. BOTTOM
BR. BEDROOM
B.W. BACK OF WALL, BOTTOM OF WALL
CAB. CABINET
C.B.CATCH BASIN
C.B.C. CALIFORNIA BUILDING CODE
C.R.C. CALIFORNIA RESIDENTIAL CODE
CEM.CEMENT
C.G.CORNER GUARD
CHAN.CHANNEL
CHG.CHANGE
C.I. CAST IRON
C.J. CONTROL / CONSTRUCT./CEILING JOINT
CLG. CEILING
CLKG. CAULKING
CLR. CLEAR, CLEARANCE
CNTR.COUNTER
CONC.CONCRETE
COND.CONDITION
CONST. CONSTRUCT, CONSTRUCTION
CORR.CORRIDOR, CORROSIVE
CTSK. COUNTER SINK, COUNTERSUNK
CTR. CENTER
DBL. DOUBLE
DECO.DECORATIVE
DEPT. DEPARTMENT
DET. DETAIL
D.F.DRINKING FOUNTAIN, DOUGLAS FIR
DIA.DIAMETER
DIAG. DIAGONAL
DIM. DIMENSION
DN. DOWN
DR. DOOR
D.S.DOWNSPOUT
D.S.P. DRY STANDPIPE
DWG. DRAWING(S)
E. EXISTING, EAST, ENTRY, EACH
E.J. EXPANSION JOINT
ELEC. ELECTRIC, ELECTRICAL
ELEV. ELEVATOR
EMER.EMERGENCY
ENCL. ENCLOSED, ENCLOSURE
E.P.ELECTRICAL PANEL, END POINT
EQ. EQUAL
EQV. EQUIVALENT
EQUIP.EQUIPMENT
E.W. EACH WAY
EXH. EXHAUST
EXPO.EXPOSED
EXT. EXTERIOR
E.G.EXISTING GRADE
F.FIXED
F.A. FIRE ALARM
FAC. FACTORY
F.C.O. FLOOR CLEAN OUT
F.D.FLOOR DRAIN
FDN. FOUNDATION
F.E. FIRE EXTINGUISHER
F.E.C. FIRE EXTINGUISHER CABINET
F.G.FINISH GRADE
FIXT.FIXTURE
F.J. FLOOR JOIST
F.L. FLOW LINE
FLASH. FLASHING
FLR. FLOOR
FLUOR. FLUORESCENT
F.O.C. FACE OF CONCRETE/CURB
F.O.F. FACE OF FINISH
F.O.S. FACE OF STUD / STRUCTURE / SHEATHING
F.O.M.FACE OF MASONRY
FP. FIREPLACE
F.S. FLOOR SINK, FINISH SURFACE
FT.FOOT, FEET
FTG. FOOTING
FURR.FURRING
FUT. FUTURE
F.V. FIELD VERIFY
GA. GAUGE
GALV. GALVANIZED
G.B.GRAB BAR, GRADE BEAM
G.C.GENERAL CONTRACTOR
GEN.GENERAL
G.F.I.GROUND FAULT INTERRUPT
G.I. GALVANIZED IRON
G.L.B. GLU-LAM BEAM
GND.GROUND
GR. GRADE
GYP. GYPSUM
G.P.GRADE PLANE
H./HT. HIGH, HEIGHT
H.B.HOSE BIBB
H.C.HOLLOW CORE
HD. HARD, HEAD
HDR.HEADER
HDWD.HARDWOOD
HDWR.HARDWARE
H.M. HOLLOW METAL
HORIZ. HORIZONTAL
HR. HOUR
HVAC HEATING VENTILATING AIR CONDITIONING
I.D. INTERIOR DESIGNER, INSIDE DIAMETER/DIMENSION
IN.INCH
INSUL.INSULATION
INT.INTERIOR
INV.INVERT/INVERTED
JAN. JANITOR
JT.JOINT
JST.JOIST
KIT. KITCHEN
L.LOW, LINEN
L.A. LANDSCAPED AREA
LAB. LABORATORY
LAM. LAMINATED
LAV. LAVATORY
LBS. POUNDS
LFA.LOAD FROM ABOVE
L.H. LEFT HAND
LKR. LOCKER
LT.LIGHT
LUM. LUMINOUS, LUMENS
MAINT. MAINTENANCE
MAS.MASONRY
MAT. MATERIAL
MAX.MAXIMUM
M.B.METAL BOLT
M.C. MEDICINE CABINET
MECH.MECHANICAL
MEMB.MEMBRANE
MTL. METAL
MFGR.MANUFACTURER
M.H. MANHOLE
MIN. MINIMUM
MIR. MIRROR
MISC. MISCELLANEOUS
M.O. MASONRY OPENING
MT. MOUNTED
MUL. MULLION
N. NEW, NORTH
NAT. NATURAL
N.I.C.NOT IN CONTRACT, CONTACT
N.G.NATURAL GRADE
NO. NUMBER
NOM.NOMINAL
N.T.S. NOT TO SCALE
O/.OVER
O.A.OVERALL
OBS. OBSCURE
O.C.ON CENTER
O.D.OUTSIDE DIAMETER, DIMENSION
O.F.D. OVERFLOW DRAIN
OFF. OFFICE
OPNG.OPENING
OPP. OPPOSITE
PERIM. PERIMETER
PL.PROPERTY LINE, PLATE
P.LAM. PLASTIC LAMINATE
PLAS. PLASTER
PLUMB. PLUMBING
PLYWD. PLYWOOD
PNT. PAINT(ED)
P.O.C. POINT OF CONTACT, CONNECTION
PR. PAIR
PROJ. PROJECTION
PSL. PARALLEL STRAND LAMINATE
PT. POINT
R.A.RETURN AIR
RAD. RADIUS
R.D.ROOF DRAIN
R.D.L. ROOF DRAIN LEADER
RECPT. RECEPTACLE
RECT. RECTANGLE, RECTANGULAR
REF. REFERENCE
REFR.REFRIGERATOR
REG.REGULAR, REGISTER
REINF. REINFORCE(D), REINFORCEMENT
REQ'D. REQUIRED
RESIL.RESILIENT
RET. RETAIN(ING), RETURN
RM. ROOM
R.O.ROUGH OPENING
R.R.ROOF RAFTER
RWD. REDWOOD
S. SOUTH
S.A.SUPPLY AIR
S.C.SOLID CORE
S.C.D. SEAT COVER DISPENSER
SCHED. SCHEDULE
S.D.SUBDRAIN, SOAP DISPENSER
SEC. SECTION
SEL. SELECT(ED)
SH. SHELF
SHT. SHEET
SHT'G.SHEATHING
SIM.SIMILAR
SIMP. SIMPSON
S.J. SOFFIT JOIST
S.S.STAINLESS STEEL
S.SK.SERVICE SINK
STA. STATION
STD. STANDARD
STL.STEEL
STOR.STORAGE
STRUCT. STRUCTURE, STRUCTURAL
SUSP. SUSPEND(ED)
SYM.SYMMETRICAL
SYS. SYSTEM
T.TREAD, TRASH
T.C.TOP OF CURB
T.CL. TIME CLOCK
TEL.TELEPHONE
TEMP.TEMPERED
TER. TERRAZZO
T & G TONGUE & GROOVE
THK. THICK, THICKNESS
T.P. TOP OF PAVING
T.PL. TOP OF PLATE
T.O.S. TOP OF STRUCTURE, SHEATHING, SLAB
TRANS. TRANSFORMER
T.S. TOP OF STEP
T.W.TOP OF WALL
TYP. TYPICAL
U. UNDER
U.B.C. UNIFORMBUILDING CODE
U.G.UNDERGROUND
U.L. UNDERWRITER'S LABORATORY
UNF. UNFINISHED
U.N.O.UNLESS NOTED OTHERWISE
UR. URINAL
V./VERT. VERTICAL
VENT. VENTILATION, VENTILATING
VER. VERIFY
V.T.R. VENT THROUGH ROOF
W. WEST, WIDTH, WASHER
W/.WITH
WD.WOOD
W.H. WATER HEATER
W.C.WATER CLOSET
W.I. WROUGHT IRON
WP.WATERPROOF(ING)
W.W.M. WELDED WIRE MESH
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
CONTRACT DOCUMENT NOTESAGENERAL NOTESBABBREVIATIONSC
01/07/21
GENERAL
ARCHITECTURAL
NOTES110 22ND STREETMCFADDEN PLACE, LLC.
MR. MARIO MAROVIC,
MANAGING MEMBER
3334 E. COAST HWY #418
CORONA DEL MAR, CA 92625
DRC
106-110 22ND STREET, NEWPORT
BEACH, CA 92663
T-1.1
NO. REVISION DATE
PA2022-011
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
01/07/21
GENERAL
ARCHITECTURAL
NOTES110 22ND STREETMCFADDEN PLACE, LLC.
MR. MARIO MAROVIC,
MANAGING MEMBER
3334 E. COAST HWY #418
CORONA DEL MAR, CA 92625
DRC
106-110 22ND STREET, NEWPORT
BEACH, CA 92663
T-1.2
CAL GREEN -COMMERCIAL MANDATORY MEASURES
ORANGE COUNTY FIRE AUTHORITY NOTES
1. GENERAL REQUIREMENTS
A. SUBMIT TWO SETS OF LEGIBLE, SCALED PLANS WITH ONE SET OF CURRENT AND COMPLETE TECHNICAL DATA SHEETS AND ONE ELECTRONIC
COPY IN PDF FORMAT. THESE PLANS SHALL CONTAIN THE FOLLOWING INFORMATION AND ITEMS:
1) SCOPE OF WORK FOR THE PROJECT, INCLUDING NUMBER AND TYPE OF DEVICES ADDED, RELOCATED, REPLACED OR REMOVED. INDICATE THE
TYPE OF SYSTEM PROVIDED (I.E., MONITORING, FIRE ALARM SYSTEM, ETC.).
2) COMPLETE ADDRESS OF THE PROJECT (INCLUDING THE TRACT AND LOT NUMBERS).
3) NAME AND PHONE NUMBER OF THE PROJECT COORDINATOR, FACILITY OWNER, AND SYSTEM DESIGNER. EVIDENCE OF THE DESIGNER’S
QUALIFICATIONS IS TO BE PROVIDED UPON REQUEST BY THE OCFA. (NFPA 72 10.5.1)
4) PROVIDE A COPY OF THE INSTALLING CONTRACTOR’S C-10 LICENSE OR THE C-10 LICENSE NUMBER AND EXPIRATION DATE. (NFPA 72 10.5.1.2)
5) WITH THE EXCEPTION OF SOME SECURITY SYSTEM INFORMATION AND MECHANICAL CALCULATIONS, THE PLANS SHALL CONTAIN ONLY FIRE
ALARM SYSTEM INFORMATION OR BUILDING INFORMATION NEEDED TO DEMONSTRATE COMPLIANCE PROPER DESIGN.
6) WHEN A FIRE ALARM SYSTEM OR COMPONENT IS VOLUNTARILY INSTALLED, A NOTE SHALL BE PROVIDED ON THE PLANS CLEARLY INDICATING
THE BUILDING OWNER’S INTENT. THE DEVICES AND COMPONENTS SHALL BE INSTALLED PER THEIR LISTING AND APPLICABLE REQUIREMENTS OF
NFPA 72. NFPA 72 10.4.
7) PROVIDE A COPY OF THE OCFA FIRE ALARM NOTES ON THE PLANS. INSURE ALL THE FIELDS UNDER NOTE #15 (SEE PAGE 6) ARE COMPLETE.
2. DATA SHEETS
A. HIGHLIGHT ONE SET OF DATA SHEETS (STYLE, TYPE, MODEL, AMPS, VOLTS, ETC.) FOR ALL FIRE ALARM COMPONENTS. THIS SHALL INCLUDE CUT
SHEETS FOR NEW AND EXISTING DUCT DETECTORS WHEN THE SCOPE OF WORK INCLUDES INSTALLING AN ALARM SYSTEM.
B. PROVIDE ONE COPY OF CURRENT CALIFORNIA STATE FIRE MARSHAL (CSFM) LISTING SHEETS FOR ALL DEVICES AND EQUIPMENT TO BE
INSTALLED. (CFC 907.1.1)
3. SPECIFIC PLAN REQUIREMENTS
A. PROVIDE A FLOOR PLAN SHOWING THE LOCATION OF ALL INITIATING AND SIGNALING DEVICES, CONTROL AND TROUBLE-SIGNALING EQUIPMENT,
ANNUNCIATORS, POWER CONNECTORS AND ALL EGRESS-CONTROL DEVICES.
B. PROVIDE THE CEILING CONFIGURATION, SURFACE, AND HEIGHT. (NFPA 72 17.7.3.1.2)
C. IDENTIFY ZONE ASSIGNMENTS. THIS IS ALSO REQUIRED FOR ADDRESSABLE SYSTEMS. ANY EXISTING SUPPRESSION SYSTEM OR FUTURE
SUPPRESSION SYSTEM SHALL BE ON A SEPARATE ZONE. ALL ANCILLARY SYSTEMS SHALL BE ON A SEPARATE ZONE AND SHALL BE SUPERVISED BY
THE MAIN FIRE ALARM CONTROL UNIT (FACU), WHICH SHALL INITIATE A GENERAL ALARM. (CFC 907.6.3.1 AND NFPA 72 10.18.5.2)
D. PROVIDE A MATRIX OF THE MANUFACTURER, MODEL NUMBERS, AND LISTING INFORMATION FOR ALL EQUIPMENT, DEVICES, AND MATERIALS.
INCLUDE THE CSFM LISTING NUMBERS AND THE QUANTITIES OF EACH COMPONENT. (CFC 907.1.)
E. IN MATRIX FORM, PROVIDE THE SEQUENCE OF OPERATIONS THAT IDENTIFIES THE REQUIRED ACTION FOR THE ACTUATION OF ANY FIRE AND LIFE
SAFETY DEVICE OR ANCILLARY DEVICE TIED INTO THE FIRE ALARM SYSTEM (I.E. SPECIAL EGRESS CONTROL, SMOKE CONTROL, LEAK DETECTION,
AND HVAC DUCT DETECTION). SEE NFPA 72 FIGURE A.14.6.2.4 FOR A TYPICAL MATRIX LAYOUT. (CFC 907.1.)
F. IF DUCT DETECTORS ARE REQUIRED BY CODE, PROVIDE CUT SHEETS DEMONSTRATING THE DETECTORS ARE LISTED FOR THE COMPLETE
RANGE OF AIR VELOCITIES, TEMPERATURE, AND HUMIDITY EXPECTED AT THE DETECTOR PRESENT IN THE DUCT. DUCT SMOKE DETECTORS SHALL
BE CONNECTED TO THE BUILDING’S FIRE ALARM CONTROL UNIT WHEN A FIRE ALARM SYSTEM IS INSTALLED. ACTIVATION OF A DUCT SMOKE
DETECTOR SHALL INITIATE A VISIBLE AND AUDIBLE SUPERVISORY SIGNAL AT A CONSTANTLY ATTENDED LOCATION AND SHALL PERFORM THE
INTENDED FIRE SAFETY FUNCTION IN ACCORDANCE WITH THIS CODE AND THE CALIFORNIA MECHANICAL CODE. DUCT SMOKE DETECTORS SHALL
NOT BE USED AS A SUBSTITUTE FOR REQUIRED OPEN AREA DETECTION (CFC 907.3.1) IF DUCT DETECTORS ARE PART OF THE ALARM SYSTEM,
THEIR ACTIVATION SHALL INITIATE A SHUTDOWN OF ALL APPLICABLE HVAC SYSTEM(S) AND A SUPERVISORY ALARM SIGNAL TO THE CENTRAL
STATION. ACTIVATION OF THE DUCT DETECTOR ALONE SHALL NOT PUT THE ALARM SYSTEM INTO GENERAL ALARM. A REMOTE L.E.D. SHALL BE
PROVIDED IN THE CEILING AT THE DETECTOR LOCATION. (NFPA 72 17.4.7 AND NFPA 72 17.4.8)
G. A SUPERVISED REMOTE ANNUNCIATOR(S) IS REQUIRED IF THE FACU IS NOT LOCATED IN AN AREA THAT THE FIRE DEPARTMENT WOULD
NORMALLY RESPOND TO. THE ANNUNCIATOR SHALL BE PLACED IN AN AREA THAT THE FIRE DEPARTMENT WOULD RESPOND TO, TYPICALLY THE
FRONT LOBBY. (CFC 907.6.3.1.1)
H. IN STRIP MALLS OR MULTI-TENANT SUITES WITH INDIVIDUAL EXTERIOR EXITS, THE REMOTE ANNUNCIATOR SHALL BE LOCATED IN THE LOWEST
NUMBERED OR LETTERED SUITE, I.E. “A”OR “1”. IF EACH SUITE HAS A DIFFERENT ADDRESS, THE SUITE WITH THE LOWEST STREET ADDRESS SHALL
CONTAIN THE REMOTE ANNUNCIATOR. (CFC 907.6.3.1.1)
I. SPECIFY THE FIRE ALARM DEVICE MOUNTING HEIGHTS AND LOCATIONS. (NFPA 72)
4. SECONDARY POWER SUPPLY
A. VOLTAGE DROP CALCULATIONS SHALL BE ON THE PLANS. THE VOLTAGE DROP SHALL NOT EXCEED THE MINIMUM DEVICE SPECIFICATIONS
NEEDED TO MEET THEIR LISTING. VOLTAGE DROP CALCULATIONS SHALL BE PROVIDED FOR THE MOST DEMANDING CIRCUIT(S) IN THE AREA OF
WORK. (CFC 907.1.2.)
B. STANDBY BATTERY CALCULATIONS SHALL BE ON THE PLANS. THESE SHALL INCLUDE BOTH STANDBY AND ALARM CONDITIONS. CALCULATIONS
ARE TO BE PERFORMED FOR 100% OF THE LOAD. ANY SECURITY DEVICE LOAD SHALL BE INCLUDED. (NFPA 72 10.6.7.2.2, CFC 907.1.2)
C. STORAGE BATTERIES SHALL BE PERMANENTLY MARKED WITH THE MONTH AND YEAR OF MANUFACTURE, USING THE MONTH/YEAR FORMAT. THE
MARKING SHALL BE PERMITTED TO BE APPLIED BY EITHER THE BATTERY MANUFACTURER OR THE INSTALLER. (NFPA 72 10.6.10.1.1)
D. WHERE THE BATTERY IS NOT MARKED WITH THE MONTH/YEAR BY THE MANUFACTURER, THE INSTALLER SHALL OBTAIN THE DATE-CODE AND
MARK THE BATTERY WITH THE MONTH/YEAR OF BATTERY MANUFACTURE. (NFPA 72 10.6.10.1.2)
E. PROVIDE A MEANS OF MONITORING THE BATTERIES AND CHARGER INTEGRITY SO THAT A BATTERY CHARGER FAILURE IS DETECTED. (NFPA 72
10.6.10.6.1)
F. FAILURE OF BATTERY CHARGER SHALL RESULT IN THE INITIATION OF A TROUBLE SIGNAL IN ACCORDANCE WITH NFPA 72 10.6.10.6.2.
G. WHEN AUXILIARY POWER AND/OR CONTROL PANELS ARE BEING ADDED TO AN EXISTING SYSTEM, DETAILED “POINT TO POINT”CONNECTION
BETWEEN THIS EQUIPMENT AND THE MAIN CONTROL PANEL, INCLUDING RELAYS AND MODULES, SHALL BE ON THE PLANS. ONLY CIRCUIT ZONES
AFFECTED BY THIS WORK NEED TO BE IDENTIFIED ON THE DRAWINGS.
5. AUXILIARY EQUIPMENT CONNECTIONS
A. ALL NEW OR MODIFIED AUTOMATIC FIRE EXTINGUISHING SYSTEMS (WET AGENT, GASEOUS SUPPRESSION, ETC.) SHALL BE MONITORED BY
REQUIRED OR OPTIONAL FIRE ALARM OR MONITORING SYSTEMS IN ACCORDANCE WITH NFPA 72. (CFC 904.3.5)
B. WHEN AN EXISTING SPRINKLER MONITORED BUILDING REQUIRES A FIRE ALARM OR A FIRE DETECTION SYSTEM THE EXISTING DUCT DETECTORS
SHALL BE CONNECTED TO THE NEW FIRE ALARM CONTROL UNIT FOR SUPERVISION. (CMC 609, CFC 907.4, CFC 907.4.1) NEW OR EXISTING SMOKE
DETECTORS INSTALLED IN DUCTS SHALL BE LISTED FOR THE AIR VELOCITY, TEMPERATURE AND HUMIDITY PRESENT IN THE DUCT.
C. IF SPECIAL EGRESS-CONTROL SYSTEMS ARE LOCATED IN THE BUILDING, THE ALARM CONTRACTOR SHALL PROVIDE A COPY OF THE APPROVED
ARCHITECTURAL PLANS THAT DEMONSTRATE COMPLIANCE WITH ALL PROVISIONS OF CBC 1008.1.9.8 AND 1008.1.9.7.
D. ALL CARD READER AND EGRESS-CONTROL DEVICES SHALL BE INDICATED ON THE FIRE ALARM PLANS. THE CODE MAY IMPOSE ADDITIONAL
REQUIREMENTS SUCH AS SMOKE DETECTION THROUGHOUT. (CBC 1008.1.9.7 AND 1008.1.9.8, CFC 907.3.2, & NFPA 72 21.9)
E. OCFA DOES NOT REQUIRE A MANUAL FIRE ALARM BOX FOR THE INITIATION OF A FIRE ALARM SIGNAL AS PERMITTED PER CFC 907.2 EXCEPTION 3.
6. REQUIREMENTS FOR VISUAL DEVICES IN A TENANT IMPROVEMENT
A. WHEN TENANT IMPROVEMENTS CREATE A NEW OR ALTERED COMMON USE AREA WITHIN AN EXISTING BUILDING, THE AREA OF REMODEL SHALL
BE PROVIDED WITH VISUAL WARNING DEVICES INSTALLED IN ACCORDANCE WITH NFPA 72 1.4.2 AND CFC 907.5.2.3.
B. IF AN EXISTING FIRE ALARM SYSTEM IS EXTENDED OR MODIFIED BY THE ADDITION OF MORE THAN TWO DEVICES OR THE ADDITION OF A NEW
CIRCUIT, AND THAT PORTION OF THE FIRE ALARM SYSTEM SERVES AN AREA OF COMMON USE, THEN THE AFFECTED AREA (EXISTING OR NEW)
SHALL ALSO BE PROVIDED WITH VISUAL WARNING DEVICE NFPA 72.1.4.2
C. IN ALL CASES, PRIORITY SHALL BE GIVEN TO THE PRODUCT LISTING CRITERIA IN DETERMINING THE EXTENT OF VISUAL WARNING DEVICE
PLACEMENT AND COVERAGE.
7. MISCELLANEOUS
A. ALL EXISTING FIRE ALARM AND MONITORING SYSTEMS UNDERGOING A CHANGE IN MONITORING COMPANIES ARE REQUIRED TO BE INSPECTED
BY THE OCFA TO VERIFY THE PROPER ELECTRONIC SIGNAL AND INFORMATION IS BEING TRANSMITTED. THIS IS TO HELP REDUCE THE NUMBER OF
NUISANCE ALARMS AND INCORRECT SIGNAL TRANSMISSIONS. A SERVICE REQUEST FORM MUST BE FILLED OUT AND AN ASSOCIATED FEE PAID AT
THE OCFA FOR THIS INSPECTION. NO PLAN REVIEW IS REQUIRED FOR THIS SCOPE OF WORK. (CFC 907.6.5 AS AMENDED)
B. ALL EMERGENCY WARNING SYSTEMS FOR HAZARDOUS MATERIALS SHALL HAVE VISUAL NOTIFICATION APPLIANCES THAT ARE BLUE IN COLOR.
AUDIBLE DEVICES SHALL BE OF A DIFFERENT TONE AND PATTERN THAN THE FIRE ALARM SYSTEM. AN APPROVED UL CENTRAL STATION, REMOTE
STATION, OR A PROPRIETARY STATION APPROVED BY THE OCFA SHALL SUPERVISE THESE EMERGENCY ALARM SYSTEMS. (CFC 5004.9, CFC
5004.10, CFC5005.4.4)
C. MANUAL FIRE ALARM PULL STATION COVERS SHALL BE EVALUATED ON A CASE BY CASE BASIS AND SHALL BE SUBJECT TO THE APPROVAL OF
OCFA. IF THE INSTALLATION IS ALLOWED THE STATION COVER SHALL NOT BE EQUIPPED WITH A SOUNDING DEVICE. (CFC 907.4.2.5)
D. MINIMUM FIRE ALARM AUDIBILITY MAY BE AFFECTED BY THE OCCUPANCY USE OR OPERATIONS, SOME EQUIPMENT MAY BE REQUIRED TO BE
SHUT DOWN BY A RELAY. IF THIS IS NEEDED TO ACHIEVE MINIMUM AUDIBILITY LEVELS, INCLUDE ON THE SEQUENCE OF OPERATIONS MATRIX.
E. THE CIRCUIT DISCONNECT PROVIDING POWER TO THE FIRE ALARM UNIT SHALL ONLY BE ACCESSIBLE TO AUTHORIZED PERSONNEL, AND SHALL
BE IDENTIFIED AS “FIRE ALARM CIRCUIT”.
F. THE INSPECTION, TESTING, AND MAINTENANCE OF SYSTEMS, THEIR INITIATING DEVISES, AND NOTIFICATION APPLIANCES SHALL COMPLY WITH
THE REQUIREMENTS OF NFPA 72 CHAPTER 14 AND CONFORM TO THE MANUFACTURER’S PUBLISHED INSTRUCTIONS.
8. SPECIAL REQUIREMENTS FOR NEW HIGH RISE FIRE SYSTEMS
A. FIRE ALARM SYSTEMS INSTALLED IN NEW HIGH RISE BUILDINGS SHALL COMPLY WITH CFC 907.2.13 AND 907.6.3.2 AS AMENDED.
B. FIRE ALARM SYSTEMS INSTALLED IN NEW HIGH RISE BUILDINGS SHALL COMPLY WITH OCFA HIGH-RISE GUIDELINE H-01.
9. WATERFLOW/MONITORING SYSTEMS
A. THE DEDICATED FUNCTION FIRE CONTROL UNIT SHALL BE PLACED IN AN AREA THAT THE FIRE DEPARTMENT WOULD RESPOND TO, TYPICALLY
THE FRONT LOBBY OR WITHIN AN ELECTRICAL, MECHANICAL, SERVICE, OR RISER ROOM WHICH CAN BE ACCESSED FROM THE EXTERIOR OF THE
BUILDING AND IS IDENTIFIED BY A SIGN INDICATING “FIRE ALARM CONTROL UNIT”. IN STRIP MALLS OR MULTI-TENANT SUITES WITH INDIVIDUAL
EXTERIOR EXITS, THE FACU SHALL BE LOCATED IN THE LOWEST NUMBERED OR LETTERED SUITE, I.E. “A”OR “1”. IF EACH SUITE HAS A DIFFERENT
ADDRESS, THE SUITE WITH THE LOWEST STREET ADDRESS SHALL CONTAIN THE FACU. CFC 907.1.2(4), CFC 1.11.2.3.1 AN ANNUNCIATOR PANEL
SHALL BE REQUIRED IF THE FACU DOES NOT PROVIDE SPECIFIC ALARM CONDITIONS ON SITE. THE ANNUNCIATOR LOCATION SHALL COMPLY WITH
THE ABOVE MENTIONED REQUIREMENTS FOR THE FACP. (CFC 907.6.3.1.1)
2
1
1
ENERGY STANDARD NOTES 3
1. ADMINISTRATIVE REQUIREMENTS: THE FOLLOWING NOTES (ITEMS) REPRESENT THE ADMINISTRATIVE REQUIREMENTS FOR ALL BUILDINGS AND SHALL
APPEAR AS NOTES ON THE PLANS.
A) THE PERSON IN CHARGE OF THE CONSTRUCTION OR INSTALLATION, WHO IS ELIGIBLE UNDER DIVISION 3 OF THE BUSINESS AND PROFESSIONS CODE TO
ACCEPT RESPONSIBILITY FOR THE CONSTRUCTION OR INSTALLATION OF REGULATED MANUFACTURED DEVICES SHALL POST, OR MAKE AVAILABLE WITH THE
BUILDING PERMIT(S) ISSUED FOR THE BUILDING, THE CERTIFICATE OF INSTALLATION DOCUMENTATION FOR MANUFACTURED DEVICES REGULATED BY THE
APPLIANCE EFFICIENCY REGULATIONS OR PART 6. SUCH CERTIFICATE OF INSTALLATION DOCUMENTATION SHALL BE MADE AVAILABLE TO THE ENFORCEMENT
AGENCY FOR ALL APPLICABLE INSPECTIONS. THESE CERTIFICATES SHALL:
I) IDENTIFY FEATURES, MATERIALS, COMPONENTS, MANUFACTURED DEVICES, AND SYSTEM DIAGNOSTIC RESULTS REQUIRED TO VERIFY COMPLIANCE WITH
THE APPLIANCE EFFICIENCY REGULATIONS AND PART 6.
II) STATE THE NUMBER OF THE BUILDING PERMIT UNDER WHICH THE CONSTRUCTION OR INSTALLATION WAS PERFORMED. SECTIONS OF THE CERTIFICATE(S),
FOR WHICH SUBMITTAL TO A HERS PROVIDER DATA REGISTRY IS REQUIRED, SHALL DISPLAY THE UNIQUE REGISTRATION NUMBER ASSIGNED BY THE HERS
DATA REGISTRY.
III) INCLUDE A DECLARATION STATEMENT INDICATING THAT THE CONSTRUCTED OR INSTALLED FEATURES, MATERIALS, COMPONENTS, OR MANUFACTURED
DEVICES CONFORM TO ALL APPLICABLE CODES AND REGULATIONS, AND TO THE REQUIREMENTS FOR SUCH DEVICES GIVEN IN THE PLANS AND
SPECIFICATIONS APPROVED BY THE LOCAL ENFORCEMENT AGENCY.
IV) BE SIGNED BY THE DOCUMENTATION AUTHOR TO CERTIFY THE DOCUMENTATION IS ACCURATE AND COMPLETE.
V) BE SIGNED BY THE INDIVIDUAL ELIGIBLE UNDER DIVISION 3 OF THE BUSINESS AND PROFESSIONS CODE TO ACCEPT RESPONSIBILITY FOR CONSTRUCTION,
OR INSTALLATION IN THE APPLICABLE CLASSIFICATION FOR THE SCOPE OF WORK SPECIFIED ON THE CERTIFICATE OF INSTALLATION DOCUMENT(S) SEC.
10-103 (A) 3 A
B) THE BUILDER SHALL PROVIDE THE BUILDING OWNER OR THE PERSON(S) RESPONSIBLE FOR OPERATION AND MAINTENANCE OF THE FEATURE, MATERIAL,
COMPONENT OR MECHANICAL DEVICE INSTALLED (IN CASE OF MULTI-TENANT OR CENTRALLY OPERATED BUILDINGS) WITH THE FOLLOWING AT THE TIME OF
OCCUPANCY:
1) COMPLIANCE INFORMATION. THE APPROPRIATE COMPLETED AND SIGNED CERTIFICATE(S) OF COMPLIANCE, CERTIFICATE(S) OF INSTALLATION,AND IF
APPLICABLE CERTIFICATE(S) OF VERIFICATION DOCUMENTATION SUBMITTED.
2) OPERATING INFORMATION. THE APPROPRIATE CERTIFICATE(S) OF COMPLIANCE AND A LIST OF THE FEATURES, MATERIALS, COMPONENTS, AND
MECHANICAL DEVICES INSTALLED IN THE BUILDING AND INSTRUCTIONS ON HOW TO OPERATE THEM CORRECTLY AND EFFICIENTLY.
3) MAINTENANCE INFORMATION. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY STATED AND INCORPORATED ON A READILY ACCESSIBLE
LABEL. THE LABEL MAY BE LIMITED TO IDENTIFYING THE OPERATION AND MAINTENANCE MANUAL.
4) VENTILATION INFORMATION. A DESCRIPTION OF THE QUANTITY OF OUTDOOR AIR THAT THE VENTILATION SYSTEM IS DESIGNED TO PROVIDE TO THE
BUILDING CONDITIONED SPACE, AND INSTRUCTIONS FOR PROPER OPERATION AND MAINTENANCE. SEC. 10-103 (B)
C) THE ENFORCEMENT AGENCY SHALL NOT ISSUE A CERTIFICATE OF OCCUPANCY UNTIL ALL REQUIRED CERTIFICATES OF VERIFICATION ARE POSTED AND
MADE AVAILABLE TO THE BUILDING DEPARTMENT FOR ALL APPLICABLE INSPECTIONS, AND THAT ALL CERTIFICATES OF VERIFICATION CONFORM TO THE
SPECIFICATIONS OF SECTION 10-103(A)5. SEC. 10-103 (D)2
2.THE FURNACE (AND/OR A/C IF PROVIDED) CAPACITY IN BTU/H, THE MANUFACTURER’S NAME, MODEL NUMBER, AND THE AFUE (AND/OR SEER) SHALL BE
SHOWN ON THE PLANS TO MATCH CALCULATIONS AND IN COMPLIANCE WITH SECTIONS 110.2 AND110.5.
3.SPECIFY HIGH EFFICIENCY HEATING/COOLING EQUIPMENT IN THE PLANS AS MODELED IN CALCULATIONS.
4.INDICATE MANUFACTURER’S NAME, MODEL NO., TYPE, CAPACITY, AND THE LOCATION OF WATER HEATER(S) ON THE PLANS.
5.PLEASE VERIFY THE FOLLOWING INFORMATION SHOWN ON ENERGY CALCULATION TO MATCH WITH MECHANICAL AND ARCHITECTURAL PLANS AND REVISE
ENERGY CALCULATION ACCORDINGLY:
A. NUMBER OF BED ROOMS (6).
B. NUMBER OF ZONES (2).
C. WATER HEATER INFORMATION (NO, TYPE, CAPACITY).
D THE MAIN CONTROL PANEL, INCLUDING RELAYS AND MODULES, SHALL BE ON THE PLANS. ONLY CIRCUIT ZONES AFFECTED BY THIS WORK NEED TO BE
IDENTIFIED ON THE DRAWINGS.
ENERGY STANDARDS (RESIDENTIAL)ENERGY STANDARDS (NON-RESIDENTIAL)
A) The Lesser of the minimum rate of outdoor air required by Sec. 120.1 (b) 2, or three complete air changes shall be supplied to the entire building during the one-hour period
immediately before the building is normally occupied. Sec. 120.1 (c) 2
B) All air distribution system ducts and plenums, including, but not limited to, building cavities, mechanical closets, air-handler boxes and support platforms used as ducts or
plenums, shall be installed, sealed and insulated to meet the requirements of the 2013 California Mechanical Code and SMACNA -006-2006 HVAC Duct Constriction Standards.
Supply-air and return-air ducts conveying heated or cooled air shall be insulated to a minimum installed level of R-8, unless ducts are in conditioned space. Sec. 120.4 (a)
C) The thermostatic controls for HVAC systems shall meet the following requirements as applicable:
a) Each space conditioning zone shall be controlled by an individual thermostatic control that responds to temperature within the zone and meets the applicable requirements of
Section (b).
b) Each Thermostatic control required by Section (a) shall be capable of being set locally or remotely by adjustment or selection of sensors to control:
1) Comfort heating down to 55 °F or lower.
2) Comfort cooling up to 85°F or higher.
3) Both heating and cooling, the thermostatic controls shall be capable of providing a temperature range or dead band of at least 5 °F within which the supply of heating and cooling
energy to the zone is shut off or reduced to a minimum. Sec. 120.2 (a) & (b)
D) Outdoor air supply and exhaust equipment shall be installed with dampers that automatically close
E) Each space-conditioning system shall be installed with controls that comply with the following:
1) Capable of automatically shutting off the system during periods of non-use and shall have:
a) An automatic time switch control device complying with Sec. 110.9, with an accessible manual override that allows operation of the system for up to 4 hours; or
b) An occupancy sensor; or
c) A four-hour timer that can be manually operated.
EXCEPTION: Mechanical systems serving retail stores and associated malls, restaurants, grocery stores, churches, and theaters equipped with 7-day programmable timers.
2) Automatically restart and temporarily operate the system as required to maintain:
a) A setback heating thermostat set point, if the system provides mechanical heating;
EXCEPTION: Area with the design winter outdoor temperature of greater than 32° F.
b) A setup cooling thermostat set point, if the system provides mechanical cooling.
EXCEPTION: Area with the design summer outdoor temperature of less than 100°F. Sec. 120.2 (e)
F) The piping for all space conditioning and service water heating systems shall be insulated in accordance with TABLE 120.3 -A. Sec. 120.3
G) Lavatories in public restrooms shall have controls that limit the water supply temperature to 110° F. Sec. 110.3 (c) 3
NO. REVISION DATE
PA2022-011
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
01/07/21
GENERAL
ARCHITECTURAL
NOTES110 22ND STREETMCFADDEN PLACE, LLC.
MR. MARIO MAROVIC,
MANAGING MEMBER
3334 E. COAST HWY #418
CORONA DEL MAR, CA 92625
DRC
106-110 22ND STREET, NEWPORT
BEACH, CA 92663
T-1.3
NO. REVISION DATE
RESIDENTIAL MINIMUM CONSTRUCTION REQUIREMENTS 2
CAL GREEN -RESIDENTIAL MANDATORY MEASURES 2
RESIDENTIAL MINIMUM CONSTRUCTION REQUIREMENTS CONT'D.
PA2022-011
UP
1.FIELD VERIFY EXISTING CONDITIONS AND ELEVATIONS. IF ANY DISCREPANCIES ARE ENCOUNTERED, NOTIFY
THE ARCHITECT PRIOR TO PROCEEDING WITH CONSTRUCTION.
2.LAW REQUIRES DIG ALERT IDENTIFICATION NUMBER BE ISSUED BEFORE A PERMIT TO EXCAVATE IS VALID.
TOLL FREE 1.800.227.2600 TWO WORKING DAYS BEFORE YOU DIG.
3.MAINTAIN A MINIMUM OF 2 % POSITIVE DRAINAGE AWAY FROM THE STRUCTURE.
4.ALL WORK SHALL BE IN ACCORDANCE WITH THE CODES OF THE GOVERNING AUTHORITY AND SPECIAL
REQUIREMENTS OF THE BUILDING PERMIT.
5.VERIFY LOCATION OF EXISTING UTILITIES PRIOR TO COMMENCEMENT OF ANY WORK.
6.A CAL-OSHA PERMIT IS REQUIRED FOR EXCAVATIONS DEEPER THAN 5' (CUT VERTICALLY) AND FOR SHORING
& UNDERPINNING. CONTRACTOR TO PROVIDE CITY W/./ COPY OF PERMIT.
7.VERIFY LOCATION OF WATER METERS, ELECTRIC METERS AND GAS METERS INDICATED ON PLANS ARE IN
ACCORDANCE WITH SERVICING UTILITY COMPANY REQUIREMENTS PRIOR TO PLACEMENT, REPORT ANY
CONFLICTS TO ARCHITECT IMMEDIATELY.
8.ALL SUBSURFACE DRAINS SHALL BE SCHEDULE 40 OR SDR 35 ABS 4" MIN.
9.CERTIFICATION OF SUITABLE FILL (INCLUDING TRENCHES, BACKFILLS, RETAINING WALLS, PAD/ROUGH
GRADE, ETC.) AND ITS SATISFACTORY PLACEMENT SHALL BE SUBMITTED BY THE SOILS ENGINEER TO THE
BUILDING DEPARTMENT.
10.ALL UTILITY TRENCH BACKFILL SHOULD BE PLACED TO THE FOLLOWING STANDARDS: 90 OF THE
LABORATORY STANDARD IF NATIVE OR SAND MATERIALS ARE USED AS BACKFILL.
11.EXTERIOR TRENCHES PARALLELING A FOOTING AND EXTENDING BELOW A 1:1 PLACE PROJECTED FROM
THE OUTSIDE BOTTOM EDGE OF THE FOOTING SHALL BE COMPACTED TO 90 % OF THE LABORATORY STANDARD.
SAND BACKFILL SHOULD NOT BE ALLOWED IN THESE TRENCH BACKFILL AREAS. DENSITY TESTING ALONG WITH
PROVING SHALL BE ACCOMPLISHED TO VERIFY THE DESIRED RESULTS.
12.FIELD INSPECTORS TO REVIEW AND APPROVE UNDERGROUND SERVICE REQUIREMENTS PRIOR TO
CONCRETE PLACEMENT.
13. PROVIDE PEDESTRIAN PROTECTION ADJACENT TO PUBLIC WAYS AS FOLLOWS:
SITE PLAN NOTES
1.EXISTING SEWER LATERAL TO BE CHANGED AND A CLEANOUT INSTALLED TO COMPLY WITH CITY
STANDARD IF ANY OF THE FOLLOWING CONDITIONS OCCUR:
A. ALTERATION TO EXISTING SEWER IS DONE
B. ADDITIONAL PLUMBING FIXTURES REQUIRE INCREASE IN SEWER SIZE
C. IF AREA OF ADDITION IS GREATER THAN 50%
D. EXISTING SEWER IS UNSANITARY
E. IF STRUCTURAL REMODEL+ADDITION IS > THAN 50%.
2.SUBMIT SEPERATE PERMIT FOR SOUND ATTENUATION FOR A/C. UNITS IF INSTALLED. SOUND LEVEL NOT TO
EXCEED 50dBA PER SECTION 10.26.045 OF THE N.B.M.C
3.DISTANCE FROM FACE OF THE FOUNDATION TO PROPERTY LINE TO BE ZONING SETBACK PLUS WALL FINISH
THICKNESS (MINIMUM).
4.A Cal-OSHA PERMIT IS REQUIRED FOR EXCAVATOR DEEPER THAN 5' AND FOR SHORING AND
UNDERPINNING. CONTRACTOR TO PROVIDE A COPY OF OSHA PERMIT.
5.SOILS ENGINEER TO REVIEW AND APPROVE FOUNDATION AND GRADING PLANS PRIOR TO ISSUING A
PERMIT.
6.ELEVATORS SHAFTS, CHUTES AND DUMBWAITER SHAFTS TO BE 1-HR RATED (2007 CBC) FOR TYPE V
BUILDINGS.
7.EXTERIOR STAIRS AND EXIT BALCONIES SHALL NOT PROJECT INTO AREAS WHERE PROTECTION OF
OPENINGS IS REQUIRED PER 2010 CBC.
8.PROVIDE SMOKE DETECTORS IN EACH HALLWAY LEADING TO SLEEPING ROOMS IN EACH SLEEPING ROOM
OF NEW AND EXISTING CONSTRUCTION, ON TOP OF STAIRWAY, AND IN EACH STORY. IN NEW CONSTRUCTION
DETECTORS TO BE HARD WIRED WITH BATTERY BACK UP. DETECTORS SHALL BE INTERCONNECTED TO SOUND
AT THE SAME TIME.
9.KEEP THREE FEET CLEAR FROM FACE OF ELECTRICAL PANEL TO ANY WALL SURFACE OR OBSTRUCTION.
10.OBTAIN FIRE SPRINKLER PERMIT PRIOR TO CALLING FOR ROOF SHEATHING INSPECTION.
11.CONTRACTOR TO PROVIDE CONSTRUCTION FENCING PROTECTION PER C.N.B.
12.THE REMOVAL OF ANY CITY TREE REQUIRES PRIOR APPROVAL FROM GENERAL SERVICES DEPT.
13.POOLS, SPAS, WALLS, FENCES, PATIO COVERS AND OTHER FREESTANDING STRUCTURES REQUIRE
SEPARATE REVIEWS AND PERMITS.
14.PROVIDE TREES IN THE PARKWAY ADJOINING THIS SITE TO THE SATISFACTION OF THE GENERAL
SERVICES DEPT. (949.644.3083). APPROVAL FROM GENERAL SERVICES IS REQUIRED ON THE INSPECTION CARD
PRIOR TO FINAL.
15.PROVIDE CONSTRUCTION FENCING FOR NEW CONSTRUCTION AND FOR ADDITION PLUS REMODEL
PROJECTS EXCEEDING 75% OF THE AREA OF PROPOSED STRUCTURE. FENCE HEIGHT TO BE BETWEEN 72" AND
84" HIGH.
16. PRIOR TO PERFORMING ANY WORK IN THE CITY RIGHT-OF-WAY AN ENCROACHMENT PERMIT MUST BE
OBTAINED FROM THE PUBLIC WORKS DEPARTMENT.
NEWPORT BEACH NOTES
SUITE 1
SUITE 2 SUITE 3
LOBBY ELEVATOR MEN'S R.R.WOMEN'S R.R.
UTILITY
RESIDENTIAL
PARKING STALL #1
COMMERCIAL
PARKING STALL #1
COMMERCIAL
PARKING STALL #2
COMMERCIAL PARKING STALL
#3/
VAN ACCESSIBLE
ACCESS AISLE MONUMENT SIGNMONUMENT SIGN
PLANTED9' - 0"8' - 6"8' - 6"1' - 0"GATE
25' - 0 5/8"18' - 0"2' - 1 1/2"18' - 0"
RESIDENTIAL CARPORT
9' - 3"9' - 0"9' - 0"1' - 0"9' - 0"9' - 0"9' - 0"1' - 0"9' - 3"
CLR.
24' - 0 1/2"
LOT 8
LOT 7
LOT 6
LOT 5
LOT 4
LOT 12 LOT 13
4' - 6"4' - 6"
N55°12'33"E 25.00'N55°12'33"E 25.00'N55°12'33"E 25.00'N34°40'53"W 94.94'N56°29'39"E 25.00'N56°29'39"E 25.00'N55°32'54"E 14.84'DELTA = 89°46'12"R= 10.00'L= 15.67'N34°40'54"W 84.54'N55°12'33"E 45.17'N34°47'27"W 25.00'22ND STREET
ALLEY
9' - 0"
F.O.F.
2' - 0"7' - 7 7/8"17' - 4 1/8"7' - 7 1/2"17' - 4 1/2"20' - 2 3/4"18' - 0"18' - 0"R.Y.S.B.10' - 0"ALLEY10' - 0"8' - 0"24' - 1 1/2"18' - 0"
2' - 2"
1
1
1
1
1
1
1
EGRESS STAIR
ELEC.STORAGE
23
4
5' - 0"5' - 0"5
6
7
7
8
9
VAN CEILING HT. APPROX. 9' ADA MIN. 7'
4' - 7 1/2"4' - 7 1/2"
10
RESIDENTIAL
PARKING STALL #2
RESIDENTIAL
PARKING STALL #3
RESIDENTIAL
PARKING STALL #4
RESIDENTIAL
PARKING STALL #5
RESIDENTIAL
PARKING STALL #6
GUEST PARKING
STALL
11
12
13
14
1' - 0"2' - 0"15' - 0"1' - 0"2' - 0"15' - 0"10
15
NOTE:NO ABV. GROUND
IMPROVEMENT SHALL BE
INSTALLED WITHIN 10 FEET
ALLEY SETBACK -THE 10'
FEET ALLY SETBACK SHALL
BE CONSTRUCTED OF
DRIVABLE SURFACE
NOTE:CONTRACTOR TO PROVIDE A
DETECTABLE WARNING PRODUCT SAMPLE TO
THE BUILDING INSPECTOR FOR APPROVAL OF
COLOR CONTRAST WITH FINISH SURFACE.
6' - 7"65' - 10 1/2"4 1/2"
COMMERCIAL CARPORT
16
17
25' - 0"15
15
4
16
16
16
18
18
18
18
18
19 20 16 16
2' - 0"72' - 7 1/2"4 1/2"1' - 1 5/8"
75' - 0"
1' - 10 3/4"
ENCROACHMENT
7/8"
ENCROACHMENT
7/8"
ENCROACHMENT
1"
ON-STREET PARKING STALLS ON-STREET PARKING STALL
21
21
21
21
1' - 3
"1' - 3"VERTI-I-PACK
FRONT FEED 3 CU/YD
VERTI-I-PACK
FRONT FEED 3 CU/YD
EXIT
PASSAGEWAY
GATE GATE
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
01/07/21
ARCHITECTURAL
SITE PLAN110 22ND STREETMCFADDEN PLACE, LLC.
MR. MARIO MAROVIC,
MANAGING MEMBER
3334 E. COAST HWY #418
CORONA DEL MAR, CA 92625
DRC
106-110 22ND STREET, NEWPORT
BEACH, CA 92663
A-0.0
1
2
KEYNOTE LEGEND
1 OUTLINE OF EXISTING STRUCTURE TO BE REMOVED
2 CURB
3 GUTTER
4 CENTERLINE/FLOWLINE OF ALLEY
5 CENTERLINE OF STREET
6 (E.) SIDEWALK - NOT A PART
7 STRUCTURAL STEEL COLUMN PER STRUCT., REF. STRUCT DWGS. - PAINT & SEAL AS REQ'D.
8 LOADING AND UNLOADING ACCESS AISLE SERVING PARKING SPACES SHALL COMPLY WITH SECTION 11B-502.3.
SHALL BE MARKED WITH A BLUE PAINTED BORDER LINE AROUND THE PERIMETER. THE AREA WITHIN THE BLUE
BORDERLINES SHALL BE MARKED WITH "HATCHED LINES".
9 SURFACE IDENTIFICATION 36" x 36" INTERNATIONAL SYMBOL OF ACCESSIBILITY MUST BE LOCATED IN STALL SO
THAT IT IS VISIBLE BY A TRAFFIC ENFORCEMENT OFFICE WHEN A VEHICLE IS PROPERLY PARKED IN THE STALL
(CENTERED AT ENTRANCE TO STALL RECOMMENDED)
10 WHEEL STOP INSTALLED WITH FURTHEST FACE 30" AWAY FROM INTERIOR END OF PARKING SPACE - REF. DTL.
3/T-3.1
11 ALL ACCESSIBLE ENTRIES SHALL HAVE A MIN. 5" x 5" INTERNATIONAL SYMBOL OF ACCESSIBILITY DISPLAYED ON
THE STRIKE SIDE OF THE DOOR - REF. DTL. 2/T-3.1
12 WARNING SIGNAGE REGARDING UNAUTHORIZED USE OF DISABLED PARKING SPACES IS POSTED
CONSPICUOUSLY AT EACH ENTRENCE TO OFF STREET PARKING FACILITIES OR EMMEDIATELY ADJACENT TO
AND VISIBLE FROM EACH STALL OR SPACE - REF. DTL. 17/T-3.1
13 WALL HUNG "ACCESSIBLE PARKING" SIGN TO BE CENTERED AT THE INTERIOR END OF PARKING SPACE,
DESIGNED FOR "VAN ACCECIBLE" WHERE APPROPRIATE - REF. DTL. 18 & 19/T-3.1
14 COLUMN - SIZE PER STRUCT.
15 EXISTING STRUCTURE - NOT A PART
16 (E.) WATER METER LOCATION (REF. SURVEY & CIVIL DWGS.)
17 (E.) SEWER M.H. (REF. SURVEY & CIVIL DWGS.)
18 (E.) SEWER C.O. LOCATION (REF. SURVEY & CIVIL DWGS.)
19 (E.) CABLE TV. BOX
20 (E.) ELECTRICAL VAULT - REF. CIVIL & MEP
21 PROPERTY LINE
PROJECT
NORTH
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE
(F.O.S.) TYP. U.N.O. ROUNDED TO THE NEAREST 1/8" -CONTACT ARCHITECT IN WRITING FOR
ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
TRUE
NORTH
IMPROVEMENTS NOTE:
ALL IMPROVEMENTS SHALL BE CONSTRUCTED AS REQUIRED BY ORDINANCE AND PUBLIC
WORKS DEPARTMENT.
UTILITIES NOTE:
ALL EXISTING OVERHEAD UTILITIES SHALL BE UNDERGROUND.
P.O.W. NOTE:
IN CASE OF DAMAGE DONE TO PUBLIC WORKS IMPROVEMENTS SURROUNDING THE
DEVELOPEMENT SITE BY THE PRIVATE CONSTRUCTION, ADDITIONAL RE-CONSTRUCTION
WITHIN THE PUBLIC RIGHT-OF-WAY COULD BE REQUIRED AT THE DISCRETION OF THE
PUBLIC WORKS INSPECTOR.
2.PRIOR TO PERFORMING ANY WORK IN THE CITY RIGHT-OF-WAY AN ENCROACHMENT
PERMIT MUST BE OBTAINED FORM THE PUBLIC WORKS DEPARTMENT.
1.ISSUANCE OF A BUILDING PERMIT DOES NOT RELIEVE APPLICANTS OF THE LEGAL
REQUIREMENTS TO OBSERVE COVENANTS, CONDITIONS AND RESTRICTIONS WHICH
MAY BE RECORDED AGAINST THE PROPERTY OR TO OBTAIN PLANS. YOU SHOULD CONTACT
YOUR COMMUNITY ASSOCIATIONS PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION
AUTHORIZED BY THIS PERMIT.
GENERAL NOTES:
FLOOR, GROUND, WALKING SURFACES AND RAMPS NOTE:
ALL FLOOR, GROUND, WALKING SURFACES AND RAMPS WITHIN THE ACCESSIBLE
ROUTE/AREA SHALL BE STABLE, FIRM, AND SLIP RESISTANCE AND SHALL COMPLY WITH
SECTION 11B-302.
3/16" = 1'-0"1 ARCHITECTURAL SITE PLAN
NO. REVISION DATE
PA2022-011
PA2022-011
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
01/07/21
3-DIMENSIONAL
VIEWS110 22ND STREETMCFADDEN PLACE, LLC.
MR. MARIO MAROVIC,
MANAGING MEMBER
3334 E. COAST HWY #418
CORONA DEL MAR, CA 92625
DRC
106-110 22ND STREET, NEWPORT
BEACH, CA 92663
A-1.0
4 AXONOMETRIC - NORTHEAST3AXONOMETRIC - NORTHWEST
1 AXONOMETRIC - SOUTHEAST2AXONOMETRIC - SOUTHWEST
NO. REVISION DATE
PA2022-011
UP
NEW WALL -2 x 6 STUDS @ 16" O.C.
NEW WALL -2 x 4 STUDS @ 16" O.C.
WALL W/. STONE VENEER -2 x 6 STUDS @ 16" O.C.
2-HR 7" CLT (CROSS LAMINATED WALL) WALL
WINDOW -REFERENCE SCHEDULE
DOOR -REFERENCE SCHEDULE
CABINET -BUILT IN CASEWORK
COLUMN -WOOD, REF. STRUCTURAL DWGS.
FURNITURE -FOR PRESENTATION PURPOSES ONLY
FIREPLACE -PREFAB GAS-ONLY APPLIANCE
PLUMBING FIXTURE -SINK (AS SELECTED)
PLUMBING FIXTURE -TOILET (AS SELECTED)
PLAN LEGEND
LIGHTING FIXTURE -REFERENCE ELECTRICAL PLANS
1-HR. & SOUND RATED FLR./CLN'G. REF. DTL. 18/AD-2
1-HR EXTERIOR FIRE RATED REF. DTL. 9/AD-2
1-HR FIRE BARRIER REF. DTL. 4,7 & 10/AD-2
101
1i
?KEYNOTE TAG -REFERENCE KEYNOTE LEGEND THIS SHT.
WINDOW TAG -REFERENCE SHEET A-7.0
DOOR TAG -REFERENCE SHEET A-7.0
1-HR. RATED FLR./CLN'G. ASS'Y (2) LAYERS 5/8" OR
1/2" TYPE 'X' GYP. BD. MIN. REF. DTL. 4/AD-2
2-HR. EXT. STUCCO METAL STUD WALL REF. 16/AD-2
CURTAIN WALL WND. TAG -REFERENCE SHEET A-7.01i
1-HR. RATED FLR./CLN'G. ASS'Y (2) LAYERS 1/2" OR
1/2" TYPE 'X' GYP. BD. MIN. REF. DTL. 7/AD-2
1-HR FIRE PARTITION WALL REF. DTL. 13/AD-2
1.PROVIDE WHOLE BUILDING MECHANICAL
VENTILATION PER ASHRAE STANDARD 62.2-2007 SECTION
4, WITH EXCEPTION THAT NATURAL VENTILATION
THROUGH DOORS AND WINDOWS IS NOT AN
ACCEPTABLE ALTERNATIVE TO WHOLE-BUILDING
VENTILATION (BEES 152(a), EXCEPTION 5 TO SECTION
152(a)). FOR CONTINUOUS WHOLE-BUILDING
VENTILATION, MIN. REQUIRED RATE OF VENTILATION IS 1
CFM FOR EACH 100 S.F. OF CONDITIONED FLOOR AREA
PLUS 7.5 CFM FOR EACH OCCUPANT (ONE OCCUPANT
PER BEDROOM +1). VENTILATION TO BE PROVIDED BY
EXHAUST AIR, SUPPLY AIR OR COMBINED EXHAUST AND
SUPPLY AIR.
2.PROVIDE IN KITCHEN LOCAL EXHAUST SYSTEM
VENTED TO OUTDOORS WITH RATE = 100 CFM (PART OF
WHOLE-BUILDING VENTILATION REQUIREMENT).
(R) MECHANICAL VENTILATION NOTE:
CALCULATIONS:
TOTAL S.F. (UNIT 'A'): 2350 S.F.
(.03)2350 SF + 7.5 CFM x OCC. (BED. +1) =
70.50 CFM + (7.5 x 4) = 100.50 CFM REQ'D.
CALCULATIONS:
TOTAL S.F. (UNIT 'B'): 2327 S.F.
(.03)2327 SF + 7.5 CFM x OCC. (BED. +1) =
69.81 CFM + (7.5 x 4) = 99.81 CFM REQ'D.
SOUND TRANSMISSION CONTROL NOTES:
1. APPROVED ACOUSTICAL SEALANT SHALL BE PROVIDED ALONG THE JOINT BETWEEN THE FLOOR AND
SEPARATION WALL.
2. ALL PENETRATIONS INTO SOUND-RATED PARTITIONS OF FLOOR-CEILING ASSEMBLIES SHALL BE SEALED
WITH APPROVED PERMANENT RESILIENT SEALANT.
3. ALL RIGID CONDUIT, DUCTS, PLUMBING PIPES AND APPLIANCE VENTS LOCATED IN SOUND ASSEMBLIES
SHALL BE ISOLATED FROM THE BUILDING CONSTRUCTION BY MEANS OF RESILIENT SLEEVES, MOUNTS OR
MINIMUM 1/4" THICK APPROVED RESILIENT MATERIAL. (GAS PIPING NEED NOT BE ISOLATED)
4. METAL VENTS AND CONDITIONED AIR DUCTS LOCATED IN SOUND ASSEMBLIES SHALL BE LINED.
(EXCEPTION: DUCTS SERVING ONLY EXIT WAYS, KITCHEN COOKING FACILITIES AND BATHROOMS NEED NOT
BE LINED.)
5. MINERAL FIBER INSULATION SHALL BE INSTALLED IN JOIST SPACES TO A POINT 12" BEYOND THE PIPE OR
DUCT, WHENEVER A PLUMBING PIPE OR DUCT PENETRATES A FLOOR-CEILING ASSEMBLY OR WHERE SUCH
UNIT PASSES THROUGH THE PLANE OF THE FLOOR CEILING ASSEMBLY WITHIN A WALL.
6. ELEC. BOXES IN OPPOSITE FACES OF WALL SHALL BE SEPARATED HORIZ. BY 24", BACK AND SIDES TO BE
SEALED WITH 1/8" RESILIENT SEALANT AND BACKED WITH 2" MINIMUM MINERAL FIBER INSULATION. (TV,
PHONE & INTCOMM. OUTLETS MUST BE INSTALLED IN BOXES ACCORDINGLY)
7. WALL-MOUNTED LAVATORIES ARE NOT PERMITTED ON SOUND RATED PARTITIONS.
SOUND TRANSMISSION CONTROL NOTES
A-4.1
A-4.0
A-4.0
1
A-4.1
2
2
1 9' - 0"8' - 6"7' - 0"
SUITE 2 SUITE 3
SUITE 1
BREEZEWAY
LOBBY
ELEVATOR
MEN'S R.R.
WOMEN'S R.R.
UTILITY
ELEC.
EGRESS STAIRACCESS AISLE
MONUMENT SIGN
GATE
PLANTED18' - 0"8' - 6"8' - 6"1' - 0"9' - 0"18' - 0"
5' - 10 3/8"
1
1' - 0"9' - 0"9' - 0"9' - 0"1' - 0"9' - 0"9' - 0"9' - 0"1' - 0"9' - 3"18' - 0"8' - 0"MONUMENT SIGNFAU FAU
OPERABLE SECURITY GATE -TO REMAIN OPEN DURING BUSINESS HOURSRESIDENTIAL
PARKING STALL #1
COMMERCIAL
PARKING STALL #1
COMMERCIAL
PARKING STALL #2
COMMERCIAL PARKING STALL
#3/
VAN ACCESSIBLE
RESIDENTIAL CARPORTVAN CEILING HT. APPROX. 9' ADA MIN. 7'
RESIDENTIAL
PARKING STALL #2
RESIDENTIAL
PARKING STALL #3
RESIDENTIAL
PARKING STALL #4
RESIDENTIAL
PARKING STALL #5
RESIDENTIAL
PARKING STALL #6
GUEST PARKING
STALL
COMMERCIAL CARPORT
R.Y.S.B.10' - 0"2' - 2"72' - 5 1/2"4 1/2"
6' - 7"65' - 10 1/2"
2' - 2"72' - 5 1/2"4 1/2"
6' - 4"16' - 1"7' - 9 1/8"7' - 2 3/8"16' - 10 5/8"12' - 8 3/8"5' - 6"10' - 2 5/8"84' - 1 7/8"2"3 5/8"94' - 7 5/8"EXIT
PASSAGEWAY CLR.5' - 0"R @ 0' -6 27/32"20
1' - 6"17' - 2 3/4"1' - 6"2' - 2 1/2"3' - 2 1/2"20' - 2 3/4"5' - 5"35' - 3"23' - 3 1/8"3' - 6"19' - 9 1/4"5' - 10"30' - 2 1/8"42' - 3 3/8"
STOR.
5' - 7"
VERTI-I-PACK
FRONT FEED 3 CU/YD
VERTI-I-PACK
FRONT FEED 3 CU/YD
(FENCED)(FENCED)
1' - 3"1' - 3"GATE GATE
FAU
STOR.8' - 6 1/8"9' - 7 1/4"6' - 11 1/8"38' - 4"22
2
2 R.Y.S.B.10' - 0"3
44
5
5 5
6
4' - 6"CLR.3' - 0"DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
01/07/21
FIRST LEVEL FLOOR
PLAN110 22ND STREETMCFADDEN PLACE, LLC.
MR. MARIO MAROVIC,
MANAGING MEMBER
3334 E. COAST HWY #418
CORONA DEL MAR, CA 92625
DRC
106-110 22ND STREET, NEWPORT
BEACH, CA 92663
A-2.1
STAIRWAY NOTE:
1.ALL STAIRWAYS SHALL HAVE AN ILLUMINATION LEVEL ON
TREAD RUNS OF NOT LESS THAN 1 FOOT CANDLE (CBC 1205.4)
2.INTERIOR AND EXTERIOR STAIRS WITHIN ACCESSIBLE ROUTE
OF TRAVEL SHALL COMPLY WITH SECTION 11B-504 -4" MIN. RISER,
7" MAX RISER & 11" MIN. TREAD DEPTH.
KEYNOTE LEGEND
1 SCHINDLER 3300' MRL TRACTION ELEVATOR - 2500 LB. FRONT OPENING SINGLE-SPEED CENTER OPENING (SSCO)
- ELEVATOR SHALL COMPLY W/. 11B-408, ASME A17.1 & EMERGENCY OPERATION AND SIGNALING DEVICE
REQUIREMENTS OF CALIFORNIA CODE OF REGULATION, TITLE 8, DIVISION 1, CHAPTER 4, SUBCHAPTER 6,
ELEVATOR SAFETY ORDER. STANDBY POWER SHALL BE PROVIDED IN ACCORDANCE WITH CHAPTER 27 AND
SECTION 3003. - ELEVATOR TO BE EXCEMPT PER EXCEPTION # 5 OF SECTTION 3002.4a FROM REQUIREMENTS OF
SECTION 3002.4.3a OF CBC PENDING LOCAL AUTHORITY APPROVAL.
2 PROPERTY LINE
3 REAR YARD SETBACK
4 WATER CLOSET SHALL BE IN COMPLIANCE WITH SECTION 11B-604 OF 2016 CBC - ENLARGED PLANS &
ELEVATION ON SHEET A-2.5, DTL. 1 & 3/T-3.2, AND 4/T3.1 - REF. COMMERCIAL CAL GREEN NOTES FOR FLOW RATE
INFO. 3/T-1.1
5 FAU - PROVIDE GAS S.O., POWER, AND VENTING AS REQ'D. BY MFGR.
6 INTERIOR AND EXTERIOR STAIRS WITHIN ACCESSIBLE ROUTE OF TRAVEL SHALL COMPLY WITH SECTION 11B-504
- 4" MIN. RISER, 7" MAX RISER & 11" MIN. TREAD DEPTH.
NOTE:ALL DIMS. ARE TO FACE OF STUD (F.O.S.) OR FACE OF
SHT'G. (F.O.S.) FOR EXTERIOR WALLS, TYP. U.N.O.
A
NOTE:ALL DOORS WITHIN ACCESSIBLE PATH OF TRAVEL SHALL
COMPLY WITH SECTION 11B-404 OF 2013 CBC -REF. 2/T-1.5
WINDOWS NOTE:
WHERE GLAZED OPENINGS ARE PROVIDED IN ACCESSIBLE ROOMS OR
SPACES FOR OPERATION BY OCCUPANTS, AT LEAST ONE OPENING
SHALL COMPLY WITH SECTION 11B-309. EACH GLAZED OPENING
REQUIRED BY AN ADMINISTRATIVE AUTHORITY TO BE OPERABLE
SHALL COMPLY WITH SECTION 11B-309.(11B-229)
JOINTS AT FIRE RATED ASSEMBLIES:
715.1 GENERAL.JOINTS INSTALLED IN OR BETWEEN FIRE-
RESISTANCE RATED WALLS, FLOOR OR FLOOR/CEILING
ASSEMBLIES AND ROOFS OR ROOF/CEILING ASSEMBLIES SHALL BE
PROTECTED BY AN APPROVED FIRE-RESISTANT JOINT SYSTEM
DESIGNED TO RESIST THE PASSAGE OF FIRE FOR A TIME PERIOD
NOT LESS THAN THE REQUIRED FIRE-RESISTANCE RATING OF THE
WALL, FLOOR OR ROOF IN OR BETWEEN WHICH IT IS INSTALLED.
FIRE-RESISTANT JOINT SYSTEMS SHALL BE TESTED IN
ACCORDANCE WITH SECTION 715.3.
715.3 FIRE TEST CRITERIA.FIRE-RESISTANT JOINT SYSTEMS SHALL
BE TESTED IN ACCORDANCE WITH THE REQUIREMENTS OF EITHER
ASTM E 1966 OR UL 2079. NONSYMMETRICAL WALL JOINT SYSTEMS
SHALL BE TESTED WITH BOTH FACES EXPOSED TO THE FURNACE,
AND THE ASSIGNED FIRE-RESISTANCE RATING SHALL BE THE
SHORTEST DURATION OBTAINED FROM THE TWO TESTS. WHEN
EVIDENCE IS FURNISHED TO SHOW THAT THE WALL WAS TESTED
WITH THE LEAST FIRE-RESISTANT SIDE EXPOSED TO THE FURNACE,
SUBJECT TO ACCEPTANCE OF THE BUILDING OFFICIAL, THE WALL
NEED NOT BE SUBJECTED TO TESTS FROM THE OPPOSITE SIDE.
FLOOR, GROUND, WALKING SURFACES AND RAMPS NOTE:
ALL FLOOR, GROUND, WALKING SURFACES AND RAMPS WITHIN THE
ACCESSIBLE ROUTE/AREA SHALL BE STABLE, FIRM, AND SLIP
RESISTANCE AND SHALL COMPLY WITH SECTION 11B-302.
1/4" = 1'-0"1 FIRST LEVEL FLOOR PLAN
B
NO. REVISION DATE
PA2022-011
DWOVEN OVENWDUP
DN WDDW
NEW WALL -2 x 6 STUDS @ 16" O.C.
NEW WALL -2 x 4 STUDS @ 16" O.C.
WALL W/. STONE VENEER -2 x 6 STUDS @ 16" O.C.
2-HR 7" CLT (CROSS LAMINATED WALL) WALL
WINDOW -REFERENCE SCHEDULE
DOOR -REFERENCE SCHEDULE
CABINET -BUILT IN CASEWORK
COLUMN -WOOD, REF. STRUCTURAL DWGS.
FURNITURE -FOR PRESENTATION PURPOSES ONLY
FIREPLACE -PREFAB GAS-ONLY APPLIANCE
PLUMBING FIXTURE -SINK (AS SELECTED)
PLUMBING FIXTURE -TOILET (AS SELECTED)
PLAN LEGEND
LIGHTING FIXTURE -REFERENCE ELECTRICAL PLANS
1-HR. & SOUND RATED FLR./CLN'G. REF. DTL. 18/AD-2
1-HR EXTERIOR FIRE RATED REF. DTL. 9/AD-2
1-HR FIRE BARRIER REF. DTL. 4,7 & 10/AD-2
101
1i
?KEYNOTE TAG -REFERENCE KEYNOTE LEGEND THIS SHT.
WINDOW TAG -REFERENCE SHEET A-7.0
DOOR TAG -REFERENCE SHEET A-7.0
1-HR. RATED FLR./CLN'G. ASS'Y (2) LAYERS 5/8" OR
1/2" TYPE 'X' GYP. BD. MIN. REF. DTL. 4/AD-2
2-HR. EXT. STUCCO METAL STUD WALL REF. 16/AD-2
CURTAIN WALL WND. TAG -REFERENCE SHEET A-7.01i
1-HR. RATED FLR./CLN'G. ASS'Y (2) LAYERS 1/2" OR
1/2" TYPE 'X' GYP. BD. MIN. REF. DTL. 7/AD-2
1-HR FIRE PARTITION WALL REF. DTL. 13/AD-2
SOUND TRANSMISSION CONTROL NOTES:
1. APPROVED ACOUSTICAL SEALANT SHALL BE PROVIDED ALONG THE JOINT BETWEEN THE FLOOR AND
SEPARATION WALL.
2. ALL PENETRATIONS INTO SOUND-RATED PARTITIONS OF FLOOR-CEILING ASSEMBLIES SHALL BE SEALED
WITH APPROVED PERMANENT RESILIENT SEALANT.
3. ALL RIGID CONDUIT, DUCTS, PLUMBING PIPES AND APPLIANCE VENTS LOCATED IN SOUND ASSEMBLIES
SHALL BE ISOLATED FROM THE BUILDING CONSTRUCTION BY MEANS OF RESILIENT SLEEVES, MOUNTS OR
MINIMUM 1/4" THICK APPROVED RESILIENT MATERIAL. (GAS PIPING NEED NOT BE ISOLATED)
4. METAL VENTS AND CONDITIONED AIR DUCTS LOCATED IN SOUND ASSEMBLIES SHALL BE LINED.
(EXCEPTION: DUCTS SERVING ONLY EXIT WAYS, KITCHEN COOKING FACILITIES AND BATHROOMS NEED NOT
BE LINED.)
5. MINERAL FIBER INSULATION SHALL BE INSTALLED IN JOIST SPACES TO A POINT 12" BEYOND THE PIPE OR
DUCT, WHENEVER A PLUMBING PIPE OR DUCT PENETRATES A FLOOR-CEILING ASSEMBLY OR WHERE SUCH
UNIT PASSES THROUGH THE PLANE OF THE FLOOR CEILING ASSEMBLY WITHIN A WALL.
6. ELEC. BOXES IN OPPOSITE FACES OF WALL SHALL BE SEPARATED HORIZ. BY 24", BACK AND SIDES TO BE
SEALED WITH 1/8" RESILIENT SEALANT AND BACKED WITH 2" MINIMUM MINERAL FIBER INSULATION. (TV,
PHONE & INTCOMM. OUTLETS MUST BE INSTALLED IN BOXES ACCORDINGLY)
7. WALL-MOUNTED LAVATORIES ARE NOT PERMITTED ON SOUND RATED PARTITIONS.
SOUND TRANSMISSION CONTROL NOTES
1.PROVIDE WHOLE BUILDING MECHANICAL
VENTILATION PER ASHRAE STANDARD 62.2-2007 SECTION
4, WITH EXCEPTION THAT NATURAL VENTILATION
THROUGH DOORS AND WINDOWS IS NOT AN
ACCEPTABLE ALTERNATIVE TO WHOLE-BUILDING
VENTILATION (BEES 152(a), EXCEPTION 5 TO SECTION
152(a)). FOR CONTINUOUS WHOLE-BUILDING
VENTILATION, MIN. REQUIRED RATE OF VENTILATION IS 1
CFM FOR EACH 100 S.F. OF CONDITIONED FLOOR AREA
PLUS 7.5 CFM FOR EACH OCCUPANT (ONE OCCUPANT
PER BEDROOM +1). VENTILATION TO BE PROVIDED BY
EXHAUST AIR, SUPPLY AIR OR COMBINED EXHAUST AND
SUPPLY AIR.
2.PROVIDE IN KITCHEN LOCAL EXHAUST SYSTEM
VENTED TO OUTDOORS WITH RATE = 100 CFM (PART OF
WHOLE-BUILDING VENTILATION REQUIREMENT).
(R) MECHANICAL VENTILATION NOTE:
CALCULATIONS:
TOTAL S.F. (UNIT 'A'): 2350 S.F.
(.03)2350 SF + 7.5 CFM x OCC. (BED. +1) =
70.50 CFM + (7.5 x 4) = 100.50 CFM REQ'D.
CALCULATIONS:
TOTAL S.F. (UNIT 'B'): 2327 S.F.
(.03)2327 SF + 7.5 CFM x OCC. (BED. +1) =
69.81 CFM + (7.5 x 4) = 99.81 CFM REQ'D.
A-4.1
A-4.0
A-4.0
1
A-4.1
2
2
1
15' - 0"15' - 0"11' - 0"11' - 3 7/8"12' - 9 1/8"
7' - 0"8' - 6"GREAT ROOM
KITCHEN
12' - 9 1/8"
GREAT ROOM
BEDROOM #3
BEDROOM #2
BATH #2
MASTER SUITE
MASTER BATH
W.I.C.W.I.C.
MASTER BATH W/C.W/C.MASTER SUITE
BEDROOM #2
BEDROOM #3
ELEVATOR
STAIRS 11' - 2"BATH #3
WET AREA WET AREA8' - 6"SEAT
BUILT-IN
SEAT
SEATSEATFIREPLACE FIREPLACE
3' - 0"BATH #3
2' - 6"11' - 0"POWDER
2' - 10"
AREA OF
REFUGE
WINE
POWDER
4' - 0"
BATH #2
SEATCORNER FIREPLACE CORNER FIREPLACE
ENTRY
OPEN TO
BELOW
OPEN TO
BELOW
OPEN TO
BELOW
BALCONY
R.
S.
R/F.
S.
R/F.
POCKET GLASS DOORS POCKET GLASS DOORS
SLIDING GLASS DOORSSLIDING GLASS DOORSSEAT
LINEN
PANTRY PANTRY
O/M.
O/M.
R.
BBQ BBQ
WOOD SCREEN
DINING DINING
KITCHEN
2' - 2"69' - 1 5/8"3' - 8 3/8"
3' - 0 5/8"7' - 6 5/8"7' - 11 1/4"2' - 7"R.Y.S.B.10' - 0"10' - 5"75' - 5"9' - 1 3/8"7' - 10"10' - 6"21' - 9"17' - 8"17' - 8"4' - 2 3/8"66' - 9 1/8"4' - 0 1/2"
26' - 1 1/4"14' - 5 1/2"26' - 2 3/8"8' - 11 5/8"73' - 6 1/4"12' - 0 5/8"BALC.
COMMON OPEN
SPACE
BENCH
SHARED
GARDENPLANTED
ENTRYHIGH WINDOWS10' - 3 3/8"15' - 6 3/4"10' - 7 1/4"10' - 6 1/4"16' - 1 1/4"6' - 0 3/4"
2' - 9 1/8"3' - 3 5/8"3' - 0"4' - 10"10' - 6"1' - 6 1/8"8' - 0"1' - 10 1/2"5' - 4 7/8"2' - 7 1/2"2' - 4"6' - 7 1/4"11' - 0 3/4"8' - 4 1/2"5' - 9 1/4"3' - 6 1/4"10 5/8"
2' - 6"
1' - 11 1/2"
20' - 3 1/2"5' - 9 3/4"9' - 0 7/8"5' - 4 5/8"20' - 4 1/8"5' - 10 1/4"5' - 1 7/8"4' - 8 1/4"2' - 8 5/8"3' - 6 1/8"5' - 5 3/4"6' - 1 5/8"2' - 7 5/8"2' - 5 1/8"4' - 0 5/8"7' - 6 5/8"2 3/4"16' - 3 7/8"5' - 9"6' - 3"9' - 10"6' - 2 3/4"11' - 7 1/4"5' - 0 3/4"11' - 7 1/4"16' - 6 5/8"12' - 0"1
1
1
1
2
3
33
3
3
4
5 5
6
7
6
7
8
9
9
10 10
11 11
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
01/07/21
SECOND LEVEL
FLOOR PLAN110 22ND STREETMCFADDEN PLACE, LLC.
MR. MARIO MAROVIC,
MANAGING MEMBER
3334 E. COAST HWY #418
CORONA DEL MAR, CA 92625
DRC
106-110 22ND STREET, NEWPORT
BEACH, CA 92663
A-2.2
STAIRWAY NOTE:
ALL STAIRWAYS SHALL HAVE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1
FOOT CANDLE (CBC 1205.4)
NOTE: ALL DIMS. ARE TO FACE OF STUD (F.O.S.) OR FACE OF
SHT'G. (F.O.S.) FOR EXTERIOR WALLS, TYP. U.N.O.
KEYNOTE LEGEND
1 PROPERTY LINE
2 REAR YARD SETBACK
3 TOILET - MIN. 24" CLR. IN FRONT, MIN. 30" CLR. WIDTH, 1.28 GALLONS/FLUSH
4 INTERIOR AND EXTERIOR STAIRS WITHIN ACCESSIBLE ROUTE OF TRAVEL SHALL COMPLY WITH SECTION
11B-504 - 4" MIN. RISER, 7" MAX RISER & 11" MIN. TREAD DEPTH.
5 KITCHEN EXHAUST HOOD - PROVIDE MIN. RATE OF 100 CFM. BEES 150(o), EXC. 5 TO 152(a) & ASHRAE STD. 62.2 -
INSTALL & PROVIDE POWER PER MFGR'S. INSTRS.
6 WASHER - PROVIDE HOOK-UPS & POWER
7 DRYER - PROVIDE 4" MIN. DIA. DUCT, 14' MAX. LENGTH INCLUDING (2) 90 DEGREE ELBOWS, DEDUCT TWO(2)
FEET FOR EACH 90 DEGREE ELBOW IN EXCESS OF TWO(2) (CMC 504.3.2)
8 SCHINDLER 3300' MRL TRACTION ELEVATOR - 2500 LB. FRONT OPENING SINGLE-SPEED CENTER OPENING
(SSCO) - ELEVATOR SHALL COMPLY W/. 11B-408, ASME A17.1 & EMERGENCY OPERATION AND SIGNALING
DEVICE REQUIREMENTS OF CALIFORNIA CODE OF REGULATION, TITLE 8, DIVISION 1, CHAPTER 4, SUBCHAPTER
6, ELEVATOR SAFETY ORDER. STANDBY POWER SHALL BE PROVIDED IN ACCORDANCE WITH CHAPTER 27 AND
SECTION 3003. - ELEVATOR TO BE EXCEMPT PER EXCEPTION # 5 OF SECTTION 3002.4a FROM REQUIREMENTS
OF SECTION 3002.4.3a OF CBC PENDING LOCAL AUTHORITY APPROVAL.
9 FURNISHINGS - AS SELECTED
10 FIREPLACE - PREFABRICATED, GAS ONLY, 'DAVINCI - LEFT/RIGHT CORNER' - ANSI Z21.50B-2014 [DTL. 22/AD-1]
(FACTORY BUILT FIREPLACES, CHIMNEYS, AND ALL OF THEIR COMPONENTS SHALL BE LISTED AND INSTALLED
IN ACCORDANCE W/. THEIR LISTING AND MFG'R. INSTALLATION INSTRUCTIONS. GASEOUS FUEL BURNING PAN
MUST BE PERMANENTLY ANCHORED TO THE FIREBOX. FIREPLACE MUST COMPLY W/. THE CALIFORNIA ENERGY
STANDARDS MANDATORY MEASURES.)
11 EXTERIOR GUARDRAIL - MIN. 42" HEIGHT - 4" MAX. SPHERE OPENING, REF. DTLS. 13,14 & 15/AD-1
1/4" = 1'-0"1 SECOND LEVEL FLOOR PLAN
A
B
NO. REVISION DATE
PA2022-011
WDOVENDN
DW
DW
1.PROVIDE WHOLE BUILDING MECHANICAL
VENTILATION PER ASHRAE STANDARD 62.2-2007 SECTION
4, WITH EXCEPTION THAT NATURAL VENTILATION
THROUGH DOORS AND WINDOWS IS NOT AN
ACCEPTABLE ALTERNATIVE TO WHOLE-BUILDING
VENTILATION (BEES 152(a), EXCEPTION 5 TO SECTION
152(a)). FOR CONTINUOUS WHOLE-BUILDING
VENTILATION, MIN. REQUIRED RATE OF VENTILATION IS 1
CFM FOR EACH 100 S.F. OF CONDITIONED FLOOR AREA
PLUS 7.5 CFM FOR EACH OCCUPANT (ONE OCCUPANT
PER BEDROOM +1). VENTILATION TO BE PROVIDED BY
EXHAUST AIR, SUPPLY AIR OR COMBINED EXHAUST AND
SUPPLY AIR.
2.PROVIDE IN KITCHEN LOCAL EXHAUST SYSTEM
VENTED TO OUTDOORS WITH RATE = 100 CFM (PART OF
WHOLE-BUILDING VENTILATION REQUIREMENT).
(R) MECHANICAL VENTILATION NOTE:
CALCULATIONS:
TOTAL S.F. (UNIT 'A'): 2350 S.F.
(.03)2350 SF + 7.5 CFM x OCC. (BED. +1) =
70.50 CFM + (7.5 x 4) = 100.50 CFM REQ'D.
CALCULATIONS:
TOTAL S.F. (UNIT 'B'): 2327 S.F.
(.03)2327 SF + 7.5 CFM x OCC. (BED. +1) =
69.81 CFM + (7.5 x 4) = 99.81 CFM REQ'D.
NEW WALL -2 x 6 STUDS @ 16" O.C.
NEW WALL -2 x 4 STUDS @ 16" O.C.
WALL W/. STONE VENEER -2 x 6 STUDS @ 16" O.C.
2-HR 7" CLT (CROSS LAMINATED WALL) WALL
WINDOW -REFERENCE SCHEDULE
DOOR -REFERENCE SCHEDULE
CABINET -BUILT IN CASEWORK
COLUMN -WOOD, REF. STRUCTURAL DWGS.
FURNITURE -FOR PRESENTATION PURPOSES ONLY
FIREPLACE -PREFAB GAS-ONLY APPLIANCE
PLUMBING FIXTURE -SINK (AS SELECTED)
PLUMBING FIXTURE -TOILET (AS SELECTED)
PLAN LEGEND
LIGHTING FIXTURE -REFERENCE ELECTRICAL PLANS
1-HR. & SOUND RATED FLR./CLN'G. REF. DTL. 18/AD-2
1-HR EXTERIOR FIRE RATED REF. DTL. 9/AD-2
1-HR FIRE BARRIER REF. DTL. 4,7 & 10/AD-2
101
1i
?KEYNOTE TAG -REFERENCE KEYNOTE LEGEND THIS SHT.
WINDOW TAG -REFERENCE SHEET A-7.0
DOOR TAG -REFERENCE SHEET A-7.0
1-HR. RATED FLR./CLN'G. ASS'Y (2) LAYERS 5/8" OR
1/2" TYPE 'X' GYP. BD. MIN. REF. DTL. 4/AD-2
2-HR. EXT. STUCCO METAL STUD WALL REF. 16/AD-2
CURTAIN WALL WND. TAG -REFERENCE SHEET A-7.01i
1-HR. RATED FLR./CLN'G. ASS'Y (2) LAYERS 1/2" OR
1/2" TYPE 'X' GYP. BD. MIN. REF. DTL. 7/AD-2
1-HR FIRE PARTITION WALL REF. DTL. 13/AD-2
SOUND TRANSMISSION CONTROL NOTES:
1. APPROVED ACOUSTICAL SEALANT SHALL BE PROVIDED ALONG THE JOINT BETWEEN THE FLOOR AND
SEPARATION WALL.
2. ALL PENETRATIONS INTO SOUND-RATED PARTITIONS OF FLOOR-CEILING ASSEMBLIES SHALL BE SEALED
WITH APPROVED PERMANENT RESILIENT SEALANT.
3. ALL RIGID CONDUIT, DUCTS, PLUMBING PIPES AND APPLIANCE VENTS LOCATED IN SOUND ASSEMBLIES
SHALL BE ISOLATED FROM THE BUILDING CONSTRUCTION BY MEANS OF RESILIENT SLEEVES, MOUNTS OR
MINIMUM 1/4" THICK APPROVED RESILIENT MATERIAL. (GAS PIPING NEED NOT BE ISOLATED)
4. METAL VENTS AND CONDITIONED AIR DUCTS LOCATED IN SOUND ASSEMBLIES SHALL BE LINED.
(EXCEPTION: DUCTS SERVING ONLY EXIT WAYS, KITCHEN COOKING FACILITIES AND BATHROOMS NEED NOT
BE LINED.)
5. MINERAL FIBER INSULATION SHALL BE INSTALLED IN JOIST SPACES TO A POINT 12" BEYOND THE PIPE OR
DUCT, WHENEVER A PLUMBING PIPE OR DUCT PENETRATES A FLOOR-CEILING ASSEMBLY OR WHERE SUCH
UNIT PASSES THROUGH THE PLANE OF THE FLOOR CEILING ASSEMBLY WITHIN A WALL.
6. ELEC. BOXES IN OPPOSITE FACES OF WALL SHALL BE SEPARATED HORIZ. BY 24", BACK AND SIDES TO BE
SEALED WITH 1/8" RESILIENT SEALANT AND BACKED WITH 2" MINIMUM MINERAL FIBER INSULATION. (TV,
PHONE & INTCOMM. OUTLETS MUST BE INSTALLED IN BOXES ACCORDINGLY)
7. WALL-MOUNTED LAVATORIES ARE NOT PERMITTED ON SOUND RATED PARTITIONS.
SOUND TRANSMISSION CONTROL NOTES
A-4.1
A-4.0
A-4.0
1
A-4.1
2
2
1 15' - 3 3/4"11' - 11 1/8"
17' - 6"GREAT ROOM
KITCHEN
GALLERY
HALLWAY
PRIMARY
BATH
W/C.
BATH #2
BEDROOM #2
BEDROOM #3
BATH #3
MASTER W.I.C.
ELEVATOR
STAIRS
PENTHOUSE
LOBBY
SHOWER
CHASE
SEAT
SEAT
SHWR.
A/C UNITS
SEAT
OPEN TO
BELOW
FIREPLACES.
R.
POCKET GLASS DOORS
SLIDING GLASS DOORS
SLIDING GLASS DOORSPLANTER POCKET DOORR.
O.TALL CAB.17' - 11 7/8"55' - 6 3/4"20' - 11 7/8"DINING
PRIMARY SUITE
VIEW DECK
UNIT 'C'
BALCONY
EQPM.
MECH. WELL
BALCONY
FIXED HORIZONTAL SHADES
1' - 9 5/8"9' - 6"3' - 8 3/8"3' - 2 3/8"2' - 6 7/8"6' - 10 1/8"17' - 8"5' - 9 1/4"15' - 0"4' - 7 5/8"4' - 2 1/2"4' - 2 7/8"9' - 0"2' - 0 5/8"12' - 3 7/8"
2' - 6"
2' - 6"
32' - 10 1/4"19' - 6"12' - 3 7/8"
5' - 8 7/8"64' - 8 1/8"4' - 7"3' - 11 5/8"3' - 3 5/8"52' - 3 1/8"2% MIN.2% MIN.2% MIN.FLAT ROOF
FLAT ROOF
18' - 7 1/2"5' - 11 3/4"40' - 0 7/8"
5' - 8 7/8"64' - 8 1/8"4' - 7"
1
1
1
1
R.Y.S.B.10' - 0"2
3
33
3
4
5
6
6
7
8
99
10 10
6' - 2 7/8"
2' - 6"
3' - 2 1/8"2' - 0"
11
DISPLAY2' - 6"6' - 6"PANTRY
BUTLER'S
PANTRY
F.12' - 0"TUB
SKYLIGHT ABV.
9 9
HIGH WINDOWSBBQ
FUTURE
SPA
MIN.
3' - 0"MIN.3' - 0"DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
01/07/21
THIRD LEVEL FLOOR
PLAN110 22ND STREETMCFADDEN PLACE, LLC.
MR. MARIO MAROVIC,
MANAGING MEMBER
3334 E. COAST HWY #418
CORONA DEL MAR, CA 92625
DRC
106-110 22ND STREET, NEWPORT
BEACH, CA 92663
A-2.3
STAIRWAY NOTE:
ALL STAIRWAYS SHALL HAVE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1
FOOT CANDLE (CBC 1205.4)
NOTE: ALL DIMS. ARE TO FACE OF STUD (F.O.S.) TYP. U.N.O.
KEYNOTE LEGEND
1 PROPERTY LINE
2 REAR YARD SETBACK
3 A/C. CONDENSER UNIT PER MEP - PROVIDE POWER AND SOUND DAMPENING PAD AS REQ'D. (SOUND ATT. REQ'D.
PER SECTION 10.26.045 NBMC UNDER SEPARATE PERMIT)
4 SCHINDLER 3300' MRL TRACTION ELEVATOR - 2500 LB. FRONT OPENING SINGLE-SPEED CENTER OPENING (SSCO) -
ELEVATOR SHALL COMPLY W/. 11B-408, ASME A17.1 & EMERGENCY OPERATION AND SIGNALING DEVICE
REQUIREMENTS OF CALIFORNIA CODE OF REGULATION, TITLE 8, DIVISION 1, CHAPTER 4, SUBCHAPTER 6,
ELEVATOR SAFETY ORDER. STANDBY POWER SHALL BE PROVIDED IN ACCORDANCE WITH CHAPTER 27 AND
SECTION 3003. - ELEVATOR TO BE EXCEMPT PER EXCEPTION # 5 OF SECTTION 3002.4a FROM REQUIREMENTS OF
SECTION 3002.4.3a OF CBC PENDING LOCAL AUTHORITY APPROVAL.
5 INTERIOR AND EXTERIOR STAIRS WITHIN ACCESSIBLE ROUTE OF TRAVEL SHALL COMPLY WITH SECTION 11B-504 -
4" MIN. RISER, 7" MAX RISER & 11" MIN. TREAD DEPTH.
6 TOILET - MIN. 24" CLR. IN FRONT, MIN. 30" CLR. WIDTH, 1.28 GALLONS/FLUSH
7 WASHER - PROVIDE HOOK-UPS & POWER
8 DRYER - PROVIDE 4" MIN. DIA. DUCT, 14' MAX. LENGTH INCLUDING (2) 90 DEGREE ELBOWS, DEDUCT TWO(2) FEET
FOR EACH 90 DEGREE ELBOW IN EXCESS OF TWO(2) (CMC 504.3.2)
9 COLUMN - SIZE PER STRUCT.
10 EXTERIOR GUARDRAIL - MIN. 42" HEIGHT - 4" MAX. SPHERE OPENING, REF. DTLS. 13,14 & 15/AD-1
11 FIREPLACE - PREFABRICATED, GAS ONLY, 'DAVINCI - LEFT/RIGHT CORNER' - ANSI Z21.50B-2014 [DTL. 22/AD-1]
(FACTORY BUILT FIREPLACES, CHIMNEYS, AND ALL OF THEIR COMPONENTS SHALL BE LISTED AND INSTALLED IN
ACCORDANCE W/. THEIR LISTING AND MFG'R. INSTALLATION INSTRUCTIONS. GASEOUS FUEL BURNING PAN MUST
BE PERMANENTLY ANCHORED TO THE FIREBOX. FIREPLACE MUST COMPLY W/. THE CALIFORNIA ENERGY
STANDARDS MANDATORY MEASURES.)
JOINTS AT FIRE RATED ASSEMBLIES:
715.1 GENERAL.JOINTS INSTALLED IN OR BETWEEN FIRE-RESISTANCE RATED WALLS,
FLOOR OR FLOOR/CEILING ASSEMBLIES AND ROOFS OR ROOF/CEILING ASSEMBLIES
SHALL BE PROTECTED BY AN APPROVED FIRE-RESISTANT JOINT SYSTEM DESIGNED TO
RESIST THE PASSAGE OF FIRE FOR A TIME PERIOD NOT LESS THAN THE REQUIRED
FIRE-RESISTANCE RATING OF THE WALL, FLOOR OR ROOF IN OR BETWEEN WHICH IT IS
INSTALLED. FIRE-RESISTANT JOINT SYSTEMS SHALL BE TESTED IN ACCORDANCE WITH
SECTION 715.3.
715.3 FIRE TEST CRITERIA.FIRE-RESISTANT JOINT SYSTEMS SHALL BE TESTED IN
ACCORDANCE WITH THE REQUIREMENTS OF EITHER ASTM E 1966 OR UL 2079.
NONSYMMETRICAL WALL JOINT SYSTEMS SHALL BE TESTED WITH BOTH FACES
EXPOSED TO THE FURNACE, AND THE ASSIGNED FIRE-RESISTANCE RATING SHALL BE
THE SHORTEST DURATION OBTAINED FROM THE TWO TESTS. WHEN EVIDENCE IS
FURNISHED TO SHOW THAT THE WALL WAS TESTED WITH THE LEAST FIRE-RESISTANT
SIDE EXPOSED TO THE FURNACE, SUBJECT TO ACCEPTANCE OF THE BUILDING
OFFICIAL, THE WALL NEED NOT BE SUBJECTED TO TESTS FROM THE OPPOSITE SIDE.
1/4" = 1'-0"1 THIRD FLOOR PLAN
A
B
NO. REVISION DATE
PA2022-011
ROOF VENTILATION NOTES: (CRC R806)
1. THE NET FREE VENTILATING AREA SHALL NOT BE LESS
THAN 1/150 OF THE AREA OF THE SPACE VENTILATED
EXCEPT THAT REDUCTION OF THE TOTAL AREA TO 1/300 IS
PERMITTED PROVIDED THAT AT LEAST 50% AND NOT MORE
THAN 80% OF THE REQUIRED VENTILATING AREA IS
PROVIDED BY VENTILATORS LOCATED IN THE UPPER
PORTION OF THE SPACE TO BE VENTILATED AT LEAST 3
FEET ABV. THE EAVE OR CORNICE VENTS W/. THE BALANCE
OF THE REQ'D. VENTILATION PROVIDED BY EAVE OR
CORNICE VENTS. (R806.3)
2.VENTILATION OPENINGS SHALL HAVE AT LEAST DIM. OF
1/16" MIN. AND 1/4" MAX. VENTILATION OPENINGS HAVING A
LEAST DIMENSION LARGER THAN 1/4" SHALL BE PROVIDED
W/. CORROSION-RESISTANT WIRE CLOTH SCREENING,
HARDWARE CLOTH, OR SIMILAR MATERIAL WITH OPENINGS
HAVING A LEAST DIM. OF 1/16" MIN. AND 1/4" MAX. OPENINGS
IN ROOF FRAMING MEMBERS SHALL CONFORM TO THE
REQ'TS. OF CRC R802.7
3. WHERE EAVE OR CORNICE VENTS ARE INSTALLED,
INSULATION SHALL NOT BLOCK THE FREE FLOW OF AIR. A
MIN. OF A 1" SPACE SHALL BE PROVIDED BETWEEN THE
INSULATION AND THE ROOF SHT'G. AND AT THE LOCATION
OF THE VENT. (R806.3)
4. UNVENTED ATTIC ASSEMBLIES (SPACES BETWEEN THE
CEILING JOISTS OF THE TOP STORY AND THE ROOF
RAFTERS) SHALL BE PERMITTED IF ALL THE FOLLOWING
CONDITIONS ARE MET:
A. THE UNVENTED ATTIC SPACE IS COMPLETELY
CONTAINED WITHIN THE BUILDING THERMAL ENVELOPE.
B. NO INTERIOR VAPOR RETARDERS ARE INSTALLED ON
THE CEILING SIDE (ATTIC FLOOR) OF THE UNVENTED ATTIC
ASSEMBLY.
C. ONE OF THE FOLLOWING 3 SHALL BE MET:
I. AIR-IMPERMEABLE INSULATION ONLY. INSULATION
SHALL BE APPLIED IN DIRECT CONTACT W/. THE UNDERSIDE
OF THE STRUCTURAL ROOF SHT'G.
II. AIR-PERMEABLE INSULATION ONLY. IN ADDITION TO
THE AIR-PERMEABLE INSULATION INSTALLED DIRECTLY
BELOW THE STRUCTURAL SHT'G., RIGID BOARD OR SHEET
INSULATION WITH AN R-VALUE OF R-4 SHALL BE INSTALLED
DIRECTLY ABOVE THE STRUCTURAL ROOF SHT'G. FOR
CONDENSATION CONTROL.
III. AIR-IMPERMEABLE AND AIR-PERMEABLE
INSULATION. THE AIR-IMPERMEABLE INSULATION SHALL BE
APPLIED IN DIRECT CONTACT WITH THE UNDERSIDE OF THE
STRUCTURAL ROOF SHT'G. FOR CONDENSATION CONTROL.
THE AIR-PERMEABLE INSULATION SHALL BE INSTALLED
DIRECTLY UNDER THE AIR-IMPERMEABLE INSULATION.
1.PROVIDE WHOLE BUILDING MECHANICAL
VENTILATION PER ASHRAE STANDARD 62.2-2007 SECTION
4, WITH EXCEPTION THAT NATURAL VENTILATION
THROUGH DOORS AND WINDOWS IS NOT AN
ACCEPTABLE ALTERNATIVE TO WHOLE-BUILDING
VENTILATION (BEES 152(a), EXCEPTION 5 TO SECTION
152(a)). FOR CONTINUOUS WHOLE-BUILDING
VENTILATION, MIN. REQUIRED RATE OF VENTILATION IS 1
CFM FOR EACH 100 S.F. OF CONDITIONED FLOOR AREA
PLUS 7.5 CFM FOR EACH OCCUPANT (ONE OCCUPANT
PER BEDROOM +1). VENTILATION TO BE PROVIDED BY
EXHAUST AIR, SUPPLY AIR OR COMBINED EXHAUST AND
SUPPLY AIR.
2.PROVIDE IN KITCHEN LOCAL EXHAUST SYSTEM
VENTED TO OUTDOORS WITH RATE = 100 CFM (PART OF
WHOLE-BUILDING VENTILATION REQUIREMENT).
(R) MECHANICAL VENTILATION NOTE:
CALCULATIONS:
TOTAL S.F. (UNIT 'A'): 2350 S.F.
(.03)2350 SF + 7.5 CFM x OCC. (BED. +1) =
70.50 CFM + (7.5 x 4) = 100.50 CFM REQ'D.
CALCULATIONS:
TOTAL S.F. (UNIT 'B'): 2327 S.F.
(.03)2327 SF + 7.5 CFM x OCC. (BED. +1) =
69.81 CFM + (7.5 x 4) = 99.81 CFM REQ'D.
F.O.F.
2' - 0"F.O.F.9' - 7 5/8"F.O.F.9' - 9 3/8"45.54'
44.96'
36.17' T.R.36.17' T.R.3:123:123:123:12
3:12
3:12
3:12
HT. CERT. REQ'D.
HT. CERT. REQ'D.
43.77'
VIEW DECK
(REF. THIRD FLOOR PLAN FOR ADDITIONAL INFORMATION)
OPEN TO BELOW
HT. CERT. REQ'D.
44.96'
HT. CERT. REQ'D.
44.90'
HT. CERT. REQ'D.
3:12 3:12
3:12HT. CERT. REQ'D.3:123:12
3:12TRELLIS
F.O.F.
2' - 0"
43.54'
1
1
1
2
2
VIEW DECK
(REF. THIRD FLOOR PLAN FOR ADDITIONAL INFORMATION)
45.54'
HT. CERT. REQ'D.3:123:123:123:12
3:12 3:122x ROOF
RAFTER (PER
STRUCT.)
INTERIOR FINISH
(PER PLANS,
WHERE OCCURS)
INSULATION
(PER
PLANS)
30# ROOF FELT MIN.
15/32" (1/2" NOMINAL)
CDX PLYWD. SHT'G. MIN.
(REF. STRUCT)
FASTENERS PER
MFGR. INSTRUCTIONS
12
SLOPE PER PLAN STANDING SEAM METAL
(ZINC OR EQUIV.) -REF.
MAT. SCHED. A/A-6,
CLASS 'A' ASSY.
TYP.6" - 10"6" MIN.
DOUBLE FOLD
3/4" LOCK, ALT. METHOD
CLEATS @ 18" O.C. MAX.
CONT. LOCK STRIP,
SOLDERED
ARCH. TO APPV.
12"-16"1-1/2" HIGHVALLEY DETAIL
PRODUCT LISTING:
ICC # ESR-2048, CB-150
INTERIOR FINISH, PER
PLAN
(WHERE OCCURS)
'TYVEK' OR EQ. BLDG. WRAP
CDX PLYWD. SHT'G. (PER STRUCT'L.)
THERMAL BATT INSUL'N.
STUCCO STOPPER
ROOFING MATERIAL (REF.
PLANS)
O/. 30# ROOF FELT & CDX
PLYWD.
ROOF SHT'G. (PER STRUCT'L.)
BASE FLASHING
EAVE FLASHING W/. DRIP (BY
ROOFING MFGR.) TO MATCH
ROOF
EXTERIOR FINISH -REF.
PLANS & MAT. SCHED.
2x SOLID BLK'G.1"CAULK & FLASHING
THERMAL BATT INSUL'N.
EAVE FLASHING W/. DRIP (BY
ROOFING
MFGR.) TO MATCH ROOF
2x3 CONT. WOOD FASCIA PAINT &
SEAL -VERIFY SIZE & FINISH W/. ARCH.
ROOFING MATERIAL, REF. PLANS
30# ROOF FELT MIN.,
TYP.
'TYVEK' OR EQ. BLDG. WRAP
PLYWD. SHT'G. (PER STRUCT'L.)
INTERIOR FINISH, PER PLAN
CAULK & SEAL
PLYWD. SHT'G. PER STRUCT.
EXTERIOR VENEER -REF. PLANS & ELEVS.
KYNAR PAINTED ALUM. GUTTER-
HALF ROUND. COLOR TO MATCH
ROOF
2x ROOF
RAFTER (PER
STRUCT.)
BASE LAYER 5/8" TYPE X GYPSUM
WALLBOARD APPLIED AT RIGHT ANGLES
TO JOIST OR TRUSSES 24" O.C. WITH 1-1/4"
TYPE S OR TYPE W DRYWALL SCREWS 24"
O.C.
INSULATION
(PER
PLANS)
30# ROOF FELT MIN.
15/32" (1/2" NOMINAL) CDX
PLYWD. SHT'G. MIN. (REF.
STRUCT) W/. EXTERIOR
GLUE APPLIED AT RIGHT
ANGLES TO TOP OF JOIST
W/. 8 D NAILS
12
SLOPE PER PLAN STANDING SEAM METAL
(ZINC OR EQUIV.) -REF.
MAT. SCHED. A/A-6,
CLASS 'A' ASSY.
TYP.6" - 10"6" MIN.
DOUBLE FOLD
3/4" LOCK, ALT. METHOD
CLEATS @ 18" O.C. MAX.
CONT. LOCK STRIP,
SOLDERED
ARCH. TO APPV.
12"-16"1-1/2" HIGHVALLEY DETAIL
PRODUCT LISTING:
ICC # ESR-2048, CB-150
FACE LAYER 5/8” TYPE X GYPSUM WALLBOARD
OR VENEER BASE APPLIED AT RIGHT ANGLES TO
JOIST OR TRUSS THROUGH BASE LAYER WITH
1-7/8" TYPE S OR TYPE W DRYWALL SCREWS 12"
O.C. AT JOINTS AND INTERMEDIATE JOIST OR
TRUSS. FACE LAYER TYPE G DRYWALL SCREWS
PLACED 2" BACK ON EITHER SIDE OF FACE
LAYER END JOINTS, 12" O.C.
.
REF. TABLE 721.1(3), ITEM 21-1.1
OF 2013 CBC
1-HR. RATED ROOF ASSEMBLY
1-HR. RATED FLR./CLN'G. ASS'Y (2) LAYERS 5/8" OR
1/2" TYPE 'X' GYP. BD. MIN. REF. DTL. 3/A-3.0
705.11 PARAPETS. PARAPETS SHALL BE PROVIDED ON EXTERIOR WALLS OF BUILDINGS.
EXCEPTIONS:A PARAPET NEED NOT BE PROVIDED ON AN EXTERIOR WALL WHERE ANY OF
THE FOLLOWING CONDITIONS EXIST:
4. ONE-HOUR FIRE-RESISTANCE-RATED EXTERIOR WALLS THAT TERMINATE AT THE
UNDERSIDE OF THE ROOF SHEATHING, DECK OR SLAB, PROVIDED:
4.1.WHERE THE ROOF/CEILING FRAMING ELEMENTS ARE PARALLEL TO THE WALLS, SUCH
FRAMING AND ELEMENTS SUPPORTING SUCH FRAMING SHALL NOT BE OF LESS THAN 1-HOUR
FIRE-RESISTANCE-RATED CONSTRUCTION FOR A WIDTH OF 4 FEET (1220 MM) FOR GROUPS R
AND U AND 10 FEET (3048 MM) FOR OTHER OCCUPANCIES, MEASURED FROM THE INTERIOR
SIDE OF THE WALL.
4.2.WHERE ROOF/CEILING FRAMING ELEMENTS ARE NOT PARALLEL TO THE WALL, THE ENTIRE
SPAN OF SUCH FRAMING AND ELEMENTS SUPPORTING SUCH FRAMING SHALL NOT BE OF
LESS THAN 1-HOUR FIRE-RESISTANCE RATED CONSTRUCTION.
4.3.OPENINGS IN THE ROOF SHALL NOT BE LOCATED WITHIN 5 FEET (1524 MM) OF THE 1-HOUR
FIRE-RESISTANCE-RATED EXTERIOR WALL FOR GROUPS R AND U AND 10 FEET (3048 MM) FOR
OTHER OCCUPANCIES, MEASURED FROM THE INTERIOR SIDE OF THE WALL.
4.4. THE ENTIRE BUILDING SHALL BE PROVIDED WITH NOT LESS THAN A CLASS B ROOF
COVERING.
PARAPETS @ EXTERIOR RATED WALL:
706.6 VERTICAL CONTINUITY.FIRE WALLS SHALL EXTEND FROM THE FOUNDATION TO A
TERMINATION POINT AT LEAST 30 INCHES (762 MM) ABOVE BOTH ADJACENT ROOFS.
EXCEPTIONS:
4.IN BUILDINGS OF TYPE III, IV AND V CONSTRUCTION, WALLS SHALL BE PERMITTED TO
TERMINATE AT THE UNDERSIDE OF COMBUSTIBLE ROOF SHEATHING OR DECKS, PROVIDED:
4.1.THERE ARE NO OPENINGS IN THE ROOF WITHIN 4FEET (1220 MM) OF THE FIRE WALL,
4.2.THE ROOF IS COVERED WITH A MINIMUM CLASS B ROOF COVERING, AND
4.3.THE ROOF SHEATHING OR DECK IS CONSTRUCTED OF FIRE-RETARDANT-TREATED WOOD
FOR A DISTANCE OF 4 FEET (1220 MM) ON BOTH SIDES OF THE WALL OR THE ROOF IS
PROTECTED WITH 5/G-INCH (15.9 MM) TYPE X GYPSUM BOARD DIRECTLY BENEATH THE
UNDERSIDE OF THE ROOF SHEATHING OR DECK, SUPPORTED BY A MINIMUM OF 2-INCH (51
MM) NOMINAL LEDGERS ATTACHED TO THE SIDES OF THE ROOF FRAMING MEMBERS FOR A
MINIMUM DISTANCE OF 4 FEET (1220 MM) ON BOTH SIDES OF THE FIRE WALL.
PARAPETS @ PARTY (FIRE) WALL:
PARAPET NOTES
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
01/07/21
ROOF PLAN &
DETAILS110 22ND STREETMCFADDEN PLACE, LLC.
MR. MARIO MAROVIC,
MANAGING MEMBER
3334 E. COAST HWY #418
CORONA DEL MAR, CA 92625
DRC
106-110 22ND STREET, NEWPORT
BEACH, CA 92663
A-3.0
KEYNOTE LEGEND
1 <varies>
2 DECO. STEEL TRELLIS - SIZE PER STRUCT
NOTES:
1. ALL DIMS. ARE TO FACE OF STUD (F.O.S.) OR FACE OF SHT'G. (F.O.S.)
TYP. U.N.O. EAVE DIMS. ARE FROM FACE OF SHT'G. TO FACE OF FINISH
FASCIA.
2. ALL ROOF ASSEMBLIES TO BE 1-HR. RATED.
1/4" = 1'-0"1 ARCHITECTURAL ROOF PLAN
1 1/2" = 1'-0"2 METAL ROOFING DETAIL
1 1/2" = 1'-0"4 RAKE DETAIL (TYP.)
1 1/2" = 1'-0"5 EAVE DETAIL (TYP.)
1 1/2" = 1'-0"3 1-HR. METAL ROOFING DETAIL
NO. REVISION DATE
PA2022-011
FIRST LEVEL (T.O.S.)
10.50'
FIRST LEVEL (T.O.S.)
10.50'
SECOND FL. PL.
20.67'
SECOND FL. PL.
20.67'
SECOND LEVEL (T.O.S.)
21.92'
SECOND LEVEL (T.O.S.)
21.92'
ROOF PL. (TYP.)
41.56'
ROOF PL. (TYP.)
41.56'
GRADE PLANE
10.54'
GRADE PLANE
10.54'
MAX FLAT
40.54'
MAX FLAT
40.54'
MAX RIDGE
45.54'
MAX RIDGE
45.54'
THIRD FLOOR PL. (TYP.)
31.42'
THIRD FLOOR PL. (TYP.)
31.42'
THIRD LEVEL (T.O.S.)
32.67'
THIRD LEVEL (T.O.S.)
32.67'30' - 0"HT. CERT. REQ'D.
PL.PL.35' - 0"30' - 0"10' - 2"1' - 3"9' - 6"1' - 3"35' - 0"11' - 5"10' - 9"8' - 10 3/4"10' - 2"1' - 3"9' - 6"1' - 3"11' - 5"10' - 9"8' - 10 3/4"36.17' T.R.
3 :12 3:12
3:1 23:12
25.42' T.R.
42.27'
36.17' T.R.
25.42' T.R.
43.77'
45.54'
HT. CERT. REQ'D.8' - 4 5/8"44.96'44.90'
HT. CERT. REQ'D.
42.27'
1
2
2
2
2
33
2
4 4
4
5
6 6
66
FIRST LEVEL (T.O.S.)
10.50'
FIRST LEVEL (T.O.S.)
10.50'
SECOND FL. PL.
20.67'
SECOND FL. PL.
20.67'
SECOND LEVEL (T.O.S.)
21.92'
SECOND LEVEL (T.O.S.)
21.92'
ROOF PL. (TYP.)
41.56'
ROOF PL. (TYP.)
41.56'
GRADE PLANE
10.54'
GRADE PLANE
10.54'
MAX FLAT
40.54'
MAX FLAT
40.54'
MAX RIDGE
45.54'
MAX RIDGE
45.54'
THIRD FLOOR PL. (TYP.)
31.42'
THIRD FLOOR PL. (TYP.)
31.42'
THIRD LEVEL (T.O.S.)
32.67'
THIRD LEVEL (T.O.S.)
32.67'
HT. CERT. REQ'D.30' - 0"35' - 0"1' - 3"9' - 6"1' - 3"10' - 2"8' - 10 3/4"10' - 9"11' - 5"19' - 7 3/4"11' - 5"1' - 3"9' - 6"1' - 3"10' - 2"35' - 0"30' - 0"PL.
PL.
4' - 10 3/4"4' - 11 7/8"13' - 0 7/8"
45.54'
3 :12
22' - 11 1/2"
42.27'
36.17'
25.42'25.42' T.R.
45.54'
HT. CERT. REQ'D.HT. CERT. REQ'D.
1
2 2
5
5
666
6
1
3
45.54'
WINDOWS & DOORS:
STUCCO VENEER
AUTHORIZED DEALER (PRODUCTS LISTED BELOW)
SUPPLIER:ASSOCIATED BUILDING SUPPLY
ADDRESS:3020 E. LA PALMA AVENUE, ANAHEIM, CA 92806
CONTACT:JOE YOUNAN
PHONE:949-872-3319
FAX: 206-666-2150
EMAIL:JYOUNAN@ABSSOCAL.COM
WEB:WWW.ASSOCIATEDBUILDINGSUPPLY.COM
ALUMINUM CLAD WINDOWS & PATIO DOORS
MANUFACTURER: JELD-WEN WINDOWS & DOORS
PRODUCT:CUSTOM COLLECTION
ADDRESS:3250 LAKEPORT BLVD. P.O. BOX 1329; KLAMATH FALLS, OREGON 97601
PHONE:541-885-7412 OR 800-535-3936
FAX:541-884-3331
WEB:WWW.JELD-WEN.COM
ALUMINUM SLIDING DOORS
MANUFACTURER: WESTERN
PRODUCT:ALUMINUM SLIDING DOORS
ADDRESS:1435 W. PIONEER ST. BREA, CA 92821
PHONE:562.905.3200
FAX:562.694.6794
WEB:WWW.PACMILLWORK.COM
MANUFACTURER:
MERLEX STUCCO
2911 ORANGE-OLIVE RD.
ORANGE, CA 92865
P: 714.637.1700
COLOR:WHITE -ARCH. TO APPROVE
APPLICATION: SMOOTH TROWELED
CODE: MIN. 7/8" THK. O/. MIN. 2-LAYERS GRADE 'D' PAPER
GUTTERS:
SUPPLIER:TBD
MATERIAL: ALUMINUM -KYNAR FINISH TO MATCH ROOFING
SHAPE: SQUARE (VERIFY SIZE W/. ARCH.)
GARAGE DOORS:
SUPPLIER:RANCH HOUSE DOORS
WWW.RANCHHOUSEDOORS.COM
STYLE: MODERN/ CONTEMPORARY
MATERIAL: CUSTOM BUILT, WOOD
WATERPROOF DECK MEMBRANE:
WESTCOAT
770 GATEWAY CENTER DRIVE
SAN DEIGO, CA 92102
800.250.4519
WWW.WESTCOAT.COM
CODE: ICC ESR-2201
PROVIDE MIN. 24 GUAGE ALUM. PAINTED KYNAR (16 OZ.) SHEETING FOR ALL
EXTERIOR FLASHING & WEATHERSTRIPPING APPLICATIONS. VERIFY W/. ARCHITECT
ANY UNCONVENTIONAL ENVELOPE WATERPROOFING AREAS PRIOR TO
INSTALLATION.
FLASHING & WEATHERSTRIPPING:
METAL ROOFING: ( CLASS 'A' )
PRODUCT: STANDING SEAM ALUMINUM -KYNAR FINISH
MANUFACTURER:
CUSTOM-BILT METALS
13940 MAGNOLIA AVE.
CHINO, CA. 91710
P: 909.664.1500
COLOR:GREY, TO BE APPROVED BY ARCH. & OWNER
NOTES:USE CONTINUOUS 16" OR 18" PANS -VERIFY W/. ARCH. SIZE & LOC'N. OF
SEAMS. (NO TRANSVERSE SEAMS)
WEIGHT:APPX. 2 PSF.
CODE: ICC ESR-2048
ALUM. WALL PANELING: KYNAR PAINTED/ MAIN LEVEL
ALL EXTERIOR GLASS GUARDRAILS MUST BE ACID-ETCHED WITH 'AVIPROTEK T' BY WALKER
TEXTURES OR SIMILAR PRODUCT TO REDUCE POSSIBLE BIRD STRIKES.
EXTERIOR GLASS GUARDRAILS:
ALUM. HORIZONTAL PANELING: KYNAR PAINTED/ UPPER LEVEL
MANUFACTURER: OCM, OLD COUNTRY MILLWORK INC.
COLOR: TINTED ALUM. SMOKY MOUNTAIN (LIGHT GREY)
FINISH: ACM PANEL -ARCH. TO APPROVE SIZING/ REVEAL
MANUFACTURER: OCM, OLD COUNTRY MILLWORK INC.
COLOR: TINTED ALUM. OBSIDIAN (DARK GREY)
FINISH: ACM PANEL -ARCH. TO APPROVE SIZING/ REVEAL
STONE VENEER
SUPPLIER: TBD
STONE TYPE:TBD (ARCH. TO APPROVE)
COLOR: LT. GRAY
APPLICATION: STACKED, ARCH. TO APPROVE SIZING/REVEAL
THICKNESS: 1" -1.5" NOMINAL
WEIGHT:TBD
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
01/07/21
EXTERIOR
ELEVATIONS110 22ND STREETMCFADDEN PLACE, LLC.
MR. MARIO MAROVIC,
MANAGING MEMBER
3334 E. COAST HWY #418
CORONA DEL MAR, CA 92625
DRC
106-110 22ND STREET, NEWPORT
BEACH, CA 92663
A-4.0
1/4" = 1'-0"1 FRONT ELEVATION - NORTH
1/4" = 1'-0"2 LEFT SIDE ELEVATION - WEST
KEYNOTE LEGEND
1 NATURAL STONE VENEER- REF. MATERIAL SCHEDULE & COORD. W/. ARCH. - REF. DTL. 8/AD-1
2 T&G WOOD VENEER - REF. MATERIAL SCHEDULE ON ELEVATIONS SHEET A-4
3 ROOF - STANDING SEAM METAL, ALUM. FINISH - COLOR AS SELECTED - REF MAT. SCHED. A/A-3.0 AND
DTLS. A, B, OR C /A-3.0, RATED ASSEMBLIES REQ'D. PER ROOF PLAN 1/A-3.0
4 KYNAR PAINTED ALUMINUM/ACM PANEL - REF. MATERIAL SCHE. A/A-4.0
5 STUCCO FINISH - MIN. 7/8" THK. W/. DIA. LATH, COLOR AS SEL., REF. DTL. 5/AD-1
6 EXTERIOR GUARDRAIL - MIN. 42" HEIGHT - 4" MAX. SPHERE OPENING, REF. DTLS. 13,14 & 15/AD-1
3
NOTE: FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT
LABELS.
1/4" = 1'-0"
MATERIAL SCHEDULE
NO. REVISION DATE
PA2022-011
FIRST LEVEL (T.O.S.)
10.50'
FIRST LEVEL (T.O.S.)
10.50'
SECOND FL. PL.
20.67'
SECOND FL. PL.
20.67'
SECOND LEVEL (T.O.S.)
21.92'
SECOND LEVEL (T.O.S.)
21.92'
ROOF PL. (TYP.)
41.56'
ROOF PL. (TYP.)
41.56'
GRADE PLANE
10.54'
GRADE PLANE
10.54'
MAX FLAT
40.54'
MAX FLAT
40.54'
MAX RIDGE
45.54'
MAX RIDGE
45.54'
THIRD FLOOR PL. (TYP.)
31.42'
THIRD FLOOR PL. (TYP.)
31.42'
THIRD LEVEL (T.O.S.)
32.67'
THIRD LEVEL (T.O.S.)
32.67'30' - 0"35' - 0"1' - 3"9' - 6"1' - 3"10' - 2"30' - 0"35' - 0"8' - 10 3/4"10' - 9"11' - 5"PL.
PL.
HT. CERT. REQ'D.8' - 10 3/4"10' - 9"11' - 5"1' - 0 1/4"7' - 10 1/2"1' - 3"9' - 6"1' - 3"10' - 2"36.17' T.R.
25.42' T.R.
PL.
HT. CERT. REQ'D.
44.96'45.54'
HT. CERT. REQ'D.
41.33'
44.96'45.54'
HT. CERT. REQ'D.
42.27'
36.17' T.W.
43.54'
2
1
1
1
2
2
4
4
5
5
5
33
6
6
FIRST LEVEL (T.O.S.)
10.50'
FIRST LEVEL (T.O.S.)
10.50'
SECOND FL. PL.
20.67'
SECOND FL. PL.
20.67'
SECOND LEVEL (T.O.S.)
21.92'
SECOND LEVEL (T.O.S.)
21.92'
ROOF PL. (TYP.)
41.56'
ROOF PL. (TYP.)
41.56'
GRADE PLANE
10.54'
GRADE PLANE
10.54'
MAX FLAT
40.54'
MAX FLAT
40.54'
MAX RIDGE
45.54'
MAX RIDGE
45.54'
THIRD FLOOR PL. (TYP.)
31.42'
THIRD FLOOR PL. (TYP.)
31.42'
THIRD LEVEL (T.O.S.)
32.67'
THIRD LEVEL (T.O.S.)
32.67'1' - 3"9' - 6"1' - 3"10' - 2"35' - 0"30' - 0"8' - 10 3/4"10' - 9"11' - 5"35' - 0"1' - 3"9' - 6"1' - 3"10' - 2"7' - 10 1/2"30' - 0"LOWER FIRST FLOOR
10.17'
LOWER FIRST FLOOR
10.17'8' - 10 3/4"10' - 9"11' - 5"HT. CERT. REQ'D.
25.42' T.R.
36.17' T.R.
PL.PL.
HT. CERT. REQ'D.HT. CERT. REQ'D.
4 1/2"
44.96'
43.54'
44.90'
HT. CERT. REQ'D.
1
1
2
3
4
55
4
1 1
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
01/07/21
EXTERIOR
ELEVATIONS110 22ND STREETMCFADDEN PLACE, LLC.
MR. MARIO MAROVIC,
MANAGING MEMBER
3334 E. COAST HWY #418
CORONA DEL MAR, CA 92625
DRC
106-110 22ND STREET, NEWPORT
BEACH, CA 92663
A-4.1
KEYNOTE LEGEND
1 STUCCO FINISH - MIN. 7/8" THK. W/. DIA. LATH, COLOR AS SEL., REF. DTL. 5/AD-1
2 T&G WOOD VENEER - REF. MATERIAL SCHEDULE ON ELEVATIONS SHEET A-4
3 NATURAL STONE VENEER- REF. MATERIAL SCHEDULE & COORD. W/. ARCH. - REF. DTL. 8/AD-1
4 ROOF - STANDING SEAM METAL, ALUM. FINISH - COLOR AS SELECTED - REF MAT. SCHED. A/A-3.0 AND DTLS. A,
B, OR C /A-3.0, RATED ASSEMBLIES REQ'D. PER ROOF PLAN 1/A-3.0
5 KYNAR PAINTED ALUMINUM/ACM PANEL - REF. MATERIAL SCHE. A/A-4.0
6 EXTERIOR GUARDRAIL - MIN. 42" HEIGHT - 4" MAX. SPHERE OPENING, REF. DTLS. 13,14 & 15/AD-1
1/4" = 1'-0"2 RIGHT SIDE ELEVATION - EAST
1/4" = 1'-0"1 REAR ELEVATION - SOUTH
NO. REVISION DATE
PA2022-011
DWOVEN OVENWDWDDW
WDOVENDW
DW
261 SF
LOBBY
691 SF
COMMERCIAL SUITE
'3'
683 SF
COMMERCIAL SUITE
'1'
259 SF
UTILITY
654 SF
COMMERCIAL SUITE
'2'
11' - 7 1/4"5' - 3 3/8"12' - 8 3/8"5' - 6"2' - 3 1/8"2' - 3 1/8"37' - 2"37' - 2"11' - 7 1/4"5' - 3 3/8"9' - 5 3/8"3' - 8 3/8"5' - 0 5/8"6' - 5 1/8"38' - 4"39' - 5 1/8"1' - 2 1/2"23' - 3 1/8"6' - 4"16' - 1"7' - 9 1/8"10"22' - 5 1/8"1A 1B 1C
2A 2B 3A 3B
3C
4A
4B
5A
192 SF
EXIT PASSAGEWAY5' - 10 1/32"3' - 6"19' - 9 1/4"22' - 5 1/8"10' - 1 1/4"27' - 0"5' - 8 3/4"13' - 9 7/8"10' - 1 1/4"4' - 9 1/4"3' - 0"8' - 5 1/8"5B
5C
5D
5E
4' - 7 1/2"14' - 4 3/4"
5' - 2"
1989 SF
RESIDENTIAL UNIT 'A'
1905 SF
RESIDENTIAL UNIT 'B'
B1
B2
B3
B4
B5
B6
B7
B8
B9 B10
B11
A1 A2
A3 A4
A5 A6
A7
A8
A9 A10 24' - 8 1/8"5' - 1 1/2"5' - 9 1/4"18' - 7"2' - 6 1/8"17' - 4"1' - 0"18' - 4"17' - 8"17' - 8"21' - 9"10' - 6"7' - 10"10' - 3 3/8"15' - 6 3/4"10' - 10"10' - 3 1/2"16' - 1 1/4"6' - 0 3/4"
17' - 9 1/8"
20' - 4 1/8"7' - 9 3/4"
12' - 7 3/8"5' - 3 3/4"
26' - 3 1/8"5' - 3 3/4"10 3/4"40' - 4 1/2"5' - 0 3/4"11' - 6 3/4"6' - 3 1/4"9' - 10"9' - 1 3/8"10' - 8 3/4"4' - 9"3' - 11 5/8"6' - 6 3/4"7' - 9 1/8"40' - 3"4' - 9 1/8"20' - 4 1/8"5' - 10 1/4"20' - 3 1/2"5' - 9 3/4"
16' - 8"8' - 10 1/8"
18' - 8 1/2"14' - 4 1/4"
22' - 3 7/8"
274 SF
COURTYARD
319 SF
UNIT 'B' DECK
249 SF
UNIT 'A' DECK
108 SF
UNIT 'A' BALCONY
35 SF
UNIT 'A' BALCONY 2 31 SF
L2 8 SF
L1 1' - 8 3/8"4' - 9 1/2"18' - 7"2775 SF
RESIDENTIAL UNIT 'C'
18' - 7 1/2"5' - 11 3/4"7' - 7 1/2"16' - 2 5/8"11' - 2 1/2"10' - 5 7/8"6' - 3 5/8"6' - 8 5/8"9' - 0 3/4"5' - 7 1/4"11' - 5 1/4"C1 C2
C3
C6
C7
C8
C9
C10
C11
C12
19' - 1 1/4"16' - 9 5/8"15' - 11"11' - 8"18' - 9 7/8"8' - 9 1/2"32' - 10 1/4"19' - 6"12' - 3 7/8"
583 SF
UNIT 'C' VIEW DECK
368 SF
UNIT 'C' BALCONY
7' - 8 3/4"
113 SF
L3
2' - 0"12' - 5 1/2"10' - 1 1/2"3' - 3 5/8"C13C15
17' - 11 1/8"
19' - 0"
24' - 7 1/4"26' - 3 1/8"2' - 0"12' - 5"4' - 0"6' - 5 7/8"2' - 6"
C14
C4
C5
22' - 5 7/8"
24' - 7 1/4"
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
01/07/21
AREA PLANS110 22ND STREETMCFADDEN PLACE, LLC.
MR. MARIO MAROVIC,
MANAGING MEMBER
3334 E. COAST HWY #418
CORONA DEL MAR, CA 92625
DRC
106-110 22ND STREET, NEWPORT
BEACH, CA 92663
AP-1
1/8" = 1'-0"1 FIRST FLOOR AREA PLAN
1/8" = 1'-0"2 SECOND FLOOR AREA PLAN
UNIT '1'
1A
1B
1C
6' -4" X 23' -4 5/8" = 142.20 SF
16' -1" X 22' -6 5/8" = 360.67 SF
3C 3' -8 3/8" X 2' -3 1/8" = 8.36 SF
3A 12' -8 3/8" X 37' -2" = 471.94 SF
3B 5' -6" X 38' -4" = 210.83 SF
2A
2B
11' -7 1/4" X 39' -5 1/8" = 457.52 SF
5' -3 3/8" X 37' -2" = 196.29 SF
UNIT '3' COMMERCIAL: 691.13 SF
4A 5' -0 5/8" X 6' -5 1/8" = 32.47 SF
4B 22' -5 1/8" X 10' -1 1/4" = 226.54 SF
UTILITY COMMERCIAL: 451.29 SF
UNIT '2'UNIT 'A'
B1
B2
20' -4 1/8" X 24' -8 1/8" = 502.02 SF
5' -10 1/4" X 17' -8" = 103.42 SF
UNIT 'B'
UNIT 'A' LIVING: 1,989.76 SF
TOTAL COMMERCIAL: 2,479.60 SF
TOTAL RESIDENTIAL: 3,934.29 SF
B3
B4
7' -9 3/4" X 17' -8" = 138.02 SF
5' -1 1/2" X 17' -9 1/8" = 91.02 SF
UNIT 'B' LIVING: 1,904.88 SF
UNIT 'C'
C1
C2
C3
18' -7 1/2" X 6' -3 5/8" = 117.38 SF
5' -11 3/4" X 6' -8 5/8" = 40.17 SF
10' -5 7/8" X 24' -7 1/4" = 258.09 SF
C6
C7
26' -3 1/8" X 2' -0" = 52.52 SF
5' -7 1/4" X 12' -5" = 69.59 SF
C8 11' -5 1/4" X 7' -8 3/4" = 88.40 SF
TOTAL RESIDENTIAL: 2,886.71 SF
C9 19' -1 1/4" X 16' -9 5/8" = 320.99 SF
UNIT 'C' LIVING: 2,774.58 SF
UNIT '2' COMMERCIAL: 653.81 SF
7' -9 1/8" X 23' -4 5/8" = 180.50 SF
UNIT '1' COMMERCIAL: 683.37 SF
TOTAL RESIDENTIAL: 260.97 SF
UNIT '3'UTILITY/RESTROOMS
BUILDING AREA SCHEDULE
LOCATION AREA COMMENTS
COMMERCIAL SUITE '1' 683 SF
COMMERCIAL SUITE '2' 654 SF
COMMERCIAL SUITE '3' 691 SF
EXIT PASSAGEWAY 192 SF
UTILITY 259 SF
2480 SF
L1 8 SF 2ND FLR. LANDING AREA
L2 31 SF 2ND FLR. LANDING AREA
L3 113 SF 3RD FLR. ELEVATOR LOBBY
LOBBY 261 SF
RESIDENTIAL UNIT 'A' 1989 SF
RESIDENTIAL UNIT 'B' 1905 SF
RESIDENTIAL UNIT 'C' 2775 SF
7082 SF
GRAND TOTAL 9561 SF
COMMERCIAL TOTAL
RESIDENTIAL TOTAL
GRAND TOTAL
1/8" = 1'-0"3 THIRD LEVEL (T.O.S.)
5A 13' -9 7/8" X 10' -1 1/4" = 139.58 SF
RESIDENTIAL LOBBY
RESIDENTIAL: 260.97 SF
B5 5' -9 1/4" X 20' -4 1/8" = 117.36 SF
B6 12' -7 3/8" X 18' -7" = 234.29 SF
B7 5' -3 3/4" X 21' -9" = 115.55 SF
B8 26' -3 1/8" X 2' -6 1/8" = 65.91 SF
B9 10' -3 1/2" X 17' -4" = 178.39 SF
B10 16' -1 1/4" X 18' -4" = 295.24 SF
A1
A2
20' -3 1/2" X 40' -4 1/2" = 819.28 SF
5' -9 3/4" X 40' -3" = 233.95 SF
A3
A4
16' -8" X 5' -0 3/4" = 84.38 SF
8' -10 1/8" X 6' -6 3/4" = 58.04 SF
A5 18' -9 1/2" X 11' -6 3/4" = 217.28 SF
A6 4' -9" X 7' -9 1/8" = 36.86 SF
A7 22' -3 7/8" X 6' -3 1/4" = 139.98 SF
A8 9' -1 3/8" X 14' -4 1/4" = 130.73 SF
A9 15' -6 3/4" X 9' -10" = 153.03 SF
A10 10' -10" X 10' -8 3/4" = 116.23 SF
L1
L2
4' -9 1/2" X 1' -8 3/8" = 8.14 SF
3' -11 5/8" X 2' -10 3/4" = 31.51 SF
STAIR LANDING
STAIR LANDING: 39.65 SF
C10 29' -7 1/8" X 17' -11 1/8" = 530.53 SF
C12 8' -9 1/2" X 12' -3 7/8" = 108.34 SF
C13 19' -0" X 10' -1 1/2" = 192.38 SF
LEGAL DESCRIPTION:
LOT 9, 10 &11, BLOCK 21
APN: 047-151-04, 047-151-05, 047-151-06
LOT INFORMATION:
EXISTING BUILDING INFORMATION:
(3) EXISTING STRUCTURES OF APPX. 2,886.50 S.F. TO BE DEMOLISHED
ZONING INFORMATION
GRAND TOTAL BUILDING AREA = 9,561.57 S.F.
FRONT SETBACK:0 FT.
REAR SETBACK:10'-0" FT. (ALLEY)
LEFT SETBACK:0 FT.
RIGHT SETBACK:0 FT.
COMMERCIAL TOTAL = 2,479.60 S.F.
RESIDENTIAL TOTAL = 7,081.97 S.F.
HEIGHT
ALLOWABLE BLDG. AREA (PER MU-W2/SB 478)
MAX RESIDENTIAL 7,082.9 SF
MIN. COMMERCIAL 2,479.02 SF
MAX FLAT 30'
MAX SLOPED 35' (3:12 MIN.)
(PER VARIANCE)
ZONED: MU-W2
SITE AREA:7,082.90 S.F.
AREA FAR REQUIREMENTS: 1.0 MAX RESIDENTIAL (SB 478)
0.35 MIN. AND 0.50 MAX COMMERCIAL
10,624.35 MAXIMUM ALLOWABLE BUILDING AREA
(9,561.57 S.F. PROPOSED)
RESIDENTIAL ALLOWABLE PER SB 478: 1.0 X 7,082.9 = 7,082.9 S.F.
COMMERCIAL ALLOWABLE: 0.5 MIN. X 7,082.9 = 3,541.45 S.F. (2,479.60 S.F. PROVIDED)
(9,561.57 S.F. ACTUAL REF. AP-1)
OUTDOOR AREA SCHEDULE
LOCATION AREA COMMENTS
UNIT 'A' BALCONY 108 SF
UNIT 'A' BALCONY 2 35 SF
UNIT 'A' DECK 249 SF
UNIT 'B' DECK 319 SF
UNIT 'C' BALCONY 368 SF
UNIT 'C' VIEW DECK 583 SF
1661 SF
COURTYARD 274 SF
274 SF
GRAND TOTAL 1936 SF
TTL. PRIVATE OUTDOOR
EXIT PASSAGEWAY
5E 27' -0" X 5' -8 3/4" = 154.69 SF
5B 14' -4 3/4" X 8' -5 1/8" = 121.39 SF
5C 4' -9 1/4" X 4' -7 1/2" = 22.09 SF
5D 3' -0" X 5' -2" = 15.50 SF
TTL. COMMON OPEN SPACE
B11 6' -0 3/4" X 10' -6" = 63.66 SF
GRAND TOTAL
(2,479.60 S.F. ACTUAL REF. AP-1)
(AREA NOT INCLUDED AT FIRST FLOOR)
L3 9' -0 3/4" X 12' -5 1/2" = 112.13 SF
ELEVATOR LOBBY: 112.13 SF
GRAND TOTAL RESIDENTIAL: 7,081.97 SF GRAND TOTAL COMMERCIAL: 2,479.60 SF
NO. REVISION DATE
C14 19' -6" X 3' -3 5/8" = 64.39 SF
C15 32' -10 1/4" X 7' -7 1/2" = 250.51 SF
C11 11' -8" X 2' -6" = 29.17 SF
C5 16' -2 5/8" X 24' -7 1/4" = 399.05 SF
C4 22' -5 7/8" X 11' -2 1/2" = 252.07 SF
(7,081.97 S.F. ACTUAL REF. AP-1)
PA2022-011