HomeMy WebLinkAboutPA2022-027_20220128_Plans_30x42DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
SHEET LISTCODE INFORMATIONSITE INFORMATIONPROJECT STATISTICSDEFERRED SUBMITTALSPROJECT DESCRIPTION
VICINITY MAP SPECIAL INSPECTIONS SHORING & EXCAVATION AGENCIES & SERVICES PROJECT DIRECTORY
13
24
57
68
911
10 BRANDONARCHITECT
STRUCTURAL ENGINEER
INTERIOR DESIGNER
ENERGY CONSULTANT
BRANDON ARCHITECTS, INC.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
P: 714.454.4040
WWW.BRANDONARCHITECTS.COM
OWNER
CIVIL ENGINEER
LANDSCAPE DESIGNER
MEP CONSULTANT
GENERAL CONTRACTOR
GEOTECHNICAL ENGINEER
SURVEYORARCHITECTS, INC.BRANDON ARCHITECTS
01.28.22
TITLE SHEETMITCHELL RESIDENCETOM & KELLY MITCHELL
141 GALAXY DR.
NEWPORT BEACH, CA 92660
CDP FIRST CHECK
2631 WAVERLY DR.
NEWPORT BEACH, CA 92663
T-1.0
MITCHELL RESIDENCE
2631 WAVERLY DR.
NEWPORT BEACH, CA 92663
TBD
BRIAN JOWETT
TOM & KELLY MITCHELL
141 GALAXY DR.
NEWPORT BEACH, CA 92660
TBD
EGA CONSULTANTS
375-C MONTE VISTA AVENUE
COSTA MESA, CA 92627
P: 949.642.9309
APEX LAND SURVEYING INC.
HUNTINGTON BEACH, CA 92646
P: 714.488.5006
E: APEXLSINC@GMAIL.COM
PAUL HADEN
C2 COLLABORATIVE
100 AVENIDA MIRAMAR
SAN CLEMENTE, CA 92672
P: 949.366.6624 x701
TBD
TBD TOM RUIZ, P.E.
FORKERT ENGINEERING, INC.
22311 BROOKHURST ST., SUITE 203
HUNTINGTON BEACH, CA 92646
P: 714.963.6793
E: TOMR@FORKERTENGINEERING.COM
TBD TBD
LEGAL DESCRIPTION:
LOT INFORMATION:
ZONED: R-1 SINGLE-UNIT RESIDENTIAL
SITE AREA:5,491 S.F. BUILDABLE AREA: 3,747 S.F.
TOTAL ALLOWABLE AREA: 2 X 3,747 S.F. = 7,494 S.F.
REQ'D. OPEN VOLUME = 3,747 S.F. X .15 = 562 S.F. (7'-6" HT. MIN.)
TOTAL ALLOWABLE ROOF DECK = 450 S.F.
EXISTING BUILDING INFORMATION:
EXISTING SINGLE FAMILY W/ GARAGE TO BE DEMOLISHED
ZONING INFORMATION:
FRONT SETBACK: 10 FT.
REAR SETBACK: 10 FT.
LEFT SETBACK: 4 FT.
RIGHT SETBACK: 4 FT.
APN: 049-183-33
LOT 48, TRACT NO. 1014, CITY OF NEWPORT BEACH, COUNTY OF
ORANGE, STATE OF CALIFORNIA
CODES:NBMC (NEWPORT BEACH MUNICIPAL CODE)
2019 CRC, 2019 CFC, 2019 CEC, 2019 CMC,
2019 CALGREEN, 2019 CAL. ENERGY CODE, 2019 CPC, AND 2018 ISPSC
OCCUPANT LOAD 1 UNIT
OCCUPANCY CLASSIFICATION R-3/U
OCCUPANCY SEPARATION (GARAGE)1-HR.
FLOOR & FLOOR-CEILING N/A.
TYPE OF CONSTRUCTION VB -SPRINKLERED
FIRE SPRINKLER YES
HEIGHT 3 -LEVELS
FLOOR AREA REF. 7/T-1.0
ALLOWABLE BLDG. AREA (PER CBC TBL. 503)N/A.
DIG ALERT:1.800.227.2600
SOUTHERN CALIFORNIA EDISON:1.714.895.0246
SOUTHERN CALIFORNIA GAS:1.800.427.2000
CITY WATER & SEWER:1.949.644.3011
PACIFIC BELL TELEPHONE:1.800.750.2355
CITY OF NEWPORT BEACH
PUBLIC WORKS DEPT.:1.949.644.3311
CITY OF NEWPORT BEACH PLANNING DEPT.:
GENERAL INFOMATION:1.949.644.3200
ZONING INFORMATION:1.949.644.3204
CITY OF NEWPORT BEACH BUILDING DEPT.:
GENERAL:1.949.644.3275
PERMITS:1.949.644.3288
INSPECTIONS:1.949.644.3255
NEWPORT BEACH FIRE DEPARTMENT:1.949.644.3106
ORANGE COUNTY HEALTH SERVICES:1.714.834.3882
1.A CAL-OSHA PERMIT IS REQUIRED FOR EXCAVATIONS DEEPER THAN 5' AND FOR SHORING AND UNDERPINNING. CONTRACTOR TO
PROVIDE A COPY OF OSHA PERMIT.
2.CONTRACTOR SHALL USE THE CITY STANDARD FORM '30-DAY NOTICE OF INTENT TO EXCAVATE' TO NOTIFY ADJACENT PROPERTY
OWNERS BY CERTIFIED MAIL 30-DAYS PRIOR TO STARTING EXCAVATION OR SHORING. CITY STANDARD FORM CAN BE OBTAINED AT:
HTTP://WWW.NEWPORTBEACHCA.GOV/HOME/SHOWDOCUMENT?ID=17395
1.REF. STRUCTURAL DRAWINGS FOR SPECIAL INSPECTIONS BY ENGINEER OF RECORD
2.HERS VERIFCATION REQUIRED, REF. ENERGY CALCULATIONS
1. LANDSCAPE PLAN; BBQ; FIRE PIT; ACCESSORY STRUCTURES, MASONRY OR CONCRETE WALLS/FENCES; RETAINING WALLS OVER 4 FT.
HIGH FROM THE BOTTOM OF THE FOUNDATION TO THE TOP OF WALL; UNDER SEPERATE REVIEWS AND PERMITS (FOR H.O.A.
PURPOSES).
2. POOLS, SPAS, WALLS, FENCES, PATIO COVERS AND OTHER FREESTANDING STRUCTURES REQUIRE SEPARATE REVIEWS AND PERMITS.
3. SUBMIT SOUND ATTENUATION DESIGN FOR HVAC EQUIPMENT PER ARI STD. 275. SOUND LEVEL NOT TO EXCEED 50dBA (55dBA WITH
TIMER, 65dBA WITH TIMER AND NEIGHBORS CONSENT). LOCATION OF MEASUREMENT TO BE AT ADJACENT PROPERTY PATIO OR
OPENING.
4. FIRE SPRINKLERS REQUIRED, CONSTRACTOR TO SUBMIT FIRE SPRINKLER DRAWINGS FOR ARCHITECT'S APPROVAL PRIOR TO
SUBMITTING TO CITY. OBTAIN FIRE SPRINKLER PERMIT PRIOR TO CALLING FOR ROOF SHEATHING INSPECTION.
5. A NOTICE OF INTENT TO DEMOLISH SHALL BE SENT VIA CERTIFIED MAIL TO ADJACENT PROPERTY OWNER(S). SIGNED RETURNED
RECEIPT MUST BE PROVIDED TO THE BUILDING DIVISION AT THE TIME OF PERMIT ISSUANCE. DEMOLITION MAY COMMENCE 30 DAYS
AFTER THE DATE OF NOTIFICATION PER NEWPORT BEACH MUNICIPAL CODE SECTION 15.02.120.
6. PV SOLAR SYSTEM (MIN. 4.3KW DC) + 5 KWH BATTERY SYSTEM PER T-24
7. ELEVATOR
NOTE: DEFERRED SUBMITTALS TO BE REVIEWED BY PROJECT ARCHITECT OR ENGINEER OF RECORD AND CERTIFIED PRIOR TO
SUBMITTAL TO LOCAL AGENCY FOR REVIEW.
C.N.B. NOTE: BRANDON ARCHITECTS, INC. IS THE DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE OF THE PROJECT, RESPONSIBLE FOR
REVIEWING AND COORDINATING SUBMITTAL DOCUMENTS PREPARED BY OTHERS, INCLUDING PHASED AND DEFERRED SUBMITTAL
ITEMS, FOR COMPATIBILITY WITH THE DESIGN OF THE BUILDING. (NBMC 12.02.010)
THE SUBJECT PROPERTY IS LOCATED IN NEWPORT BEACH, CA IN THE AREA KNOWN AS BAYSHORES ON WAVERLY DRIVE. THE LOT IS
ZONED AS R-1 AND INCLUDES AN EXISTING SINGLE FAMILY RESIDENCE AND GARAGE TO BE DEMOLISHED. THE CLIENT PROPOSES TO
BUILD A NEW 3-STORY INCLUDING ROOF DECK SINGLE FAMILY RESIDENCE OF APPX. 5,342 S.F. INCLUDING AN ATTTACHED 3-CAR
GARAGE OF APPX. 642 S.F. WOOD FRAMED WITH A SLAB ON GRADE FOUNDATION. THE PROJECT WITH BE OF A TRANSITIONAL DESIGN,
INCLUDING BUT NOT LIMITED TO THE FOLLOWING: AMPLE INDOOR/OUTDOOR SPACES INTEGRATED WITH A MODERN 'OPEN' LIVING PLAN
AS WELL AS OUTDOOR PATIOS AND BALCONY. THE EXTERIOR WILL BE PRIMARILY BRICK, WOOD SIDING, AND STANDING SEAM METAL
ROOFING. THE DESIGN CONSISTS OF A MASTER SUITE WITH EN-SUITE BATH AND WALK-IN-CLOSET, TWO (2) SECONDARY BEDROOMS
WITH EN-SUITE BATHS, LAUNDRY, KITCHEN WITH PANTRY, DINING, GREAT ROOM, AND CASITA.
SHEET INDEX
T-1.0 TITLE SHEET
T-1.1 ARCHITECTURAL GENERAL NOTES
T-1.2 SUPPLEMENTAL DOC. & NOTES
T-1.3 CALGREEN STANDARDS
SUR TOPOGRAPHIC SURVEY
C2 PRECISE GRADING PLAN
C4 CONSTRUCTION POLLUTION PREVENTION PLAN (EROSION CONTROL PLAN)
LC-1.01 CONSTRUCTION PLAN
LP-1.01 PLANTING PLAN
A-0.0 ARCHITECTURAL SITE PLAN
A-0.1 SLAB EDGE PLAN
A-0.2 AREA PLANS
A-1.0 3D VIEWS
A-2.0 FIRST LEVEL FLOOR PLAN
A-2.1 SECOND LEVEL FLOOR PLAN
A-2.2 ROOF DECK FLOOR PLAN
A-2.3 FIRST LEVEL DIMENSION PLAN
A-2.4 SECOND LEVEL DIMENSION PLAN
A-2.5 ROOF DECK DIMENSION PLAN
A-3.0 ROOF PLAN
A-4.0 EXTERIOR ELEVATIONS
A-4.1 EXTERIOR ELEVATIONS
A-5.0 BUILDING SECTIONS
NO. REVISION DATE
BUILDING AREA SCHEDULE (HOA)
LIVING
FIRST FLOOR LIVING 2247 SF
SECOND FLOOR LIVING 2032 SF
4279 SF
GARAGE
GARAGE 636 SF
636 SF
GRAND TOTAL 4916 SF
OUTDOOR AREA SCHEDULE
COVERED ENTRY 106 SF
FRONT PATIO 136 SF
MASTER BALCONY 106 SF
GRAND TOTAL 349 SF
BUILDING AREA SCHEDULE (CITY)
LIVING
FIRST FLOOR LIVING 1997 SF
SECOND FLOOR LIVING 2032 SF
4029 SF
GARAGE
GARAGE 636 SF
636 SF
GRAND TOTAL 4665 SF
TOTAL LIVING
TOTAL GARAGE
TOTAL LIVING
TOTAL GARAGE
ROOF AREA SCHEDULE
SLOPED ROOF 2642 SF
FLAT ROOF 320 SF
GRAND TOTAL 2962 SF
OPEN AREA SCHEDULE
OPEN AREA 992 SF
GRAND TOTAL 992 SF
LANDSCAPE AREA SCHEDULE
LANDSCAPE AREA 558 SF
GRAND TOTAL 558 SF
PA2022-027
DEFINITIONS: (AS USED IN THESE SPECIFICATIONS)
OWNER SHALL MEAN: TOM AND KELLY MITCHELL
ARCHITECT SHALL MEAN: BRANDON ARCHITECTS, INC., BRIAN JOWETT
CONTRACTOR SHALL MEAN:LICENSED GENERAL CONTRACTOR HIRED TO PERFORM THE WORK UNDER THIS CONTRACT
SPECIFICATIONS SHALL MEAN:WRITTEN SPECIFICATIONS IN THE PLANS OR THE "PROJECT MANUAL" (IF PROVIDED FOR THIS PROJECT)
CONTRACT DOCUMENTS SHALL MEAN: WORKING DRAWINGS APPROVED FOR BUILDING PERMIT, PLUS ANY CHANGE ORDERS OR ADDENDA TO SAME.
ARCHITECTURAL GENERAL NOTES:
1. CODES/GENERAL PROVISIONS: ALL WORK, CONSTRUCTION AND MATERIALS SHALL COMPLY WITH ALL PROVISIONS OF THE APPLICABLE BUILDING CODES AND WITH OTHER RULES, REGULATIONS AND ORDINANCES GOVERNING THE PLACE OF
CONSTRUCTION. IT IS THE RESPONSIBILITY OF THE CONTRACTOR, SUB-CONTRACTORS, AND ANYONE SUPPLYING LABOR AND/OR MATERIAL TO BRING TO THE ATTENTION OF THE ARCHITECT (VERBALLY AND IN WRITING) ANY KNOWN DISCREPANCIES OR
CONFLICT BETWEEN THE REQUIREMENTS OF THESE CODES AND THE CONTRACT DOCUMENTS (DRAWINGS). THE APPLICABLE CODES SHALL INCLUDE, BUT SHALL NOT BE LIMITED TO THOSE AS LISTED IN "CODE REVIEW" BOX. (T-1.0)
ALL WORK SHALL BE PERFORMED SO AS TO COMPLY WITH ALL LEGAL AND INDUSTRY REQUIREMENTS AND STANDARDS INCLUDING THE FOLLOWING:
-THE CALIFORNIA BUILDING CODES, 2019 EDITIONS, AND ALL APPLICABLE RELATED SPECIALTY CODES.
-THE FUNCTIONALITY STANDARDS SET FORTH IN TITLE 7 OF THE CALIFORNIA CIVIL CODE (THE "RIGHT TO REPAIR ACT").
-THE CITY OF NEWPORT BEACH MUNICIPAL CODE INCLUDING ANY WORK TIME RESTRICTION AND ANY AMENDMENT TO CALIFORNIA BUILDING CODES.
-THE MANUFACTURER'S REQUIREMENTS OF RECOMMENDATIONS FOR ANY INCORPORATED PRODUCTS.
2. FEES: CONTRACTOR AND HIS SUB-CONTRACTORS SHALL OBTAIN AND PAY FOR ALL PERMITS, LICENSES, CONSTRUCTION TAXES AND FEES REQUIRED BY CITY, COUNTY AND STATE LAWS EXCEPT THE GENERAL BUILDING PLAN CHECK FEE AND REQUIRED
REFUNDABLE DEPOSITS WHICH WILL BE PAID BY THE OWNER. CONTRACTOR SHALL ARRANGE FOR ALL METER INSTALLATIONS AND PAY ALL FEES FOR SAID METERS. CONTRACTOR SHALL PROVIDE TEMPORARY TOILET FACILITIES AND EROSION CONTROL
MEASURES AS REQUIRED BY STATE AND LOCAL BUILDING CODE.
3. CONTRACTOR'S SURVEY: CONTRACTOR SHALL VISIT THE JOB SITE AND BE RESPONSIBLE FOR HAVING COMPLETE KNOWLEDGE OF EXISTING CONDITIONS. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS WITH THOSE SHOWN ON THE DRAWINGS AND
SHALL VERIFY GRADES, CONDITIONS AND DIMENSIONS PRIOR TO COMMENCING DEMOLITION AND CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY VERBALLY AND IN WRITING OF DISCREPANCIES BETWEEN ACTUAL CONDITIONS AND
THOSE DEPICTED IN THE CONTRACT DOCUMENTS. CONTRACTOR SHALL NOTIFY ARCHITECT IMMEDIATELY VERBALLY AND IN WRITING OF ANY DISCREPANCIES FOUND WITHIN THE DRAWINGS AND SPECIFICATIONS.
4. COORDINATION OF CONSTRUCTION: CONTRACTOR IS SOLELY RESPONSIBLE FOR THE ACCURACY OF DETAILS; FOR CONFIRMING AND COORDINATING ALL QUANTITIES AND DIMENSIONS; FOR SELECTING FABRICATION PROCESSES; FOR TECHNIQUES OF
ASSEMBLY AND PERFORMANCE OF ALL WORK IN A SAFE AND SATISFACTORY MANNER. CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF ALL WORK INCLUDING THAT OF THE SUB-CONTRACTORS. CONTRACTOR SHALL PROVIDE SUPERVISION OF
THE JOB DURING ALL PHASES OF CONSTRUCTION ACTIVITIES. A COMPETENT SUPERINTENDENT SHALL BE SELECTED BY THE CONTRACTOR AND SHALL BE IN CHARGE OF THE JOB UNTIL ITS COMPLETION. CONTRACTOR AGREES TO BIND EVERY SUB-
CONTRACTOR BY THE TERMS OF THE CONTRACT AS FAR AS SUCH TERMS ARE APPLICABLE TO THE SUB-CONTRACTOR'S WORK.
5. CLEAN-UP: ALL SUBCONTRACTORS SHALL BE RESPONSIBLE FOR THE DAILY REMOVAL OF ALL DEBRIS ACCUMULATED AS A RESULT OF THEIR OPERATIONS. ALL SCRAP DEBRIS AND OTHER EXCESS MATERIAL SHALL BE LAWFULLY REMOVED FROM THE SITE,
UNLESS OTHERWISE DIRECTED BY THE CONTRACTOR.
6. TESTS AND PERMITS: CONTRACTOR SHALL ARRANGE FOR, AND SECURE REQUIRED TESTS, PERMITS AND INSPECTIONS, AND SHALL BEAR COSTS FOR SAME.
7. GUARANTEES: CONTRACTOR SHALL GUARANTEE ALL WORK, MATERIALS AND PRODUCTS FOR ONE YEAR AFTER THE DATE OF ACCEPTANCE OF THE WORK AND CONTRACTOR SHALL REPAIR OR REPLACE, OR CAUSE TO BE REPAIRED OR REPLACED ANY OR ALL
SUCH WORK TOGETHER WITH ANY OTHER WORK WHICH MAY BE DISPLACED IN DOING SO, THAT MAY PROVE DEFECTIVE WITHIN ONE YEAR, WITHOUT ADDITIONAL EXPENSE; ORDINARY WEAR AND TEAR, UNUSUAL ABUSE OR NEGLECT IS EXCEPTED. EXCEPTIONS
TO ONE YEAR GUARANTEE ARE SPECIFIED IN OTHER SECTIONS OF THE PROJECT MANUAL OR DRAWINGS. STATE LAW, OR MANUFACTURER'S GUARANTEE SHALL GOVERN IF LENGTH AND TYPES OF GUARANTEES ARE MORE STRICT OR FOR LONGER PERIODS. IT IS
UNDERSTOOD BY CONTRACTOR THAT IT IS HIS RESPONSIBILITY TO PROVIDE MATERIALS AND CONSTRUCTION WHICH WILL YIELD A REASONABLE VALUE OVER A PERIOD OF TIME WHICH MAY EXCEED THE SPECIFIED GUARANTEE AND WARRANTY PERIODS.
CONTRACTOR SHALL BE RESPONSIBLE FOR A WEATHER TIGHT BUILDING, FREE FROM DEFECTS OF MATERIALS AND WORKMANSHIP. EACH SUB-CONTRACTOR SHALL PROVIDE A WRITTEN GUARANTEE STATING THAT WORK EXECUTED BY HIM IS FREE AND WILL
REMAIN FREE FROM DEFECTS OF MATERIALS AND WORKMANSHIP FOR ONE YEAR FROM DATE OF ACCEPTANCE OF HIS WORK BY OWNER, AND THAT REPAIR AND REPLACEMENT OF SUCH DEFECTIVE WORK AND ALL OTHER WORK DAMAGED AS A RESULT THEREBY
WILL BE EXECUTED IN A TIMELY MANNER AT THE CONVENIENCE OF THE OWNER AND WITHOUT COST TO OWNER.
8. WAIVER OF LIENS: CONTRACTOR SHALL PROVIDE CERTIFIED RELEASE OF LIENS BY ALL SUBCONTRACTORS AND SUPPLIERS, OR ANYONE PROVIDING MATERIALS AND/OR LABOR AS THEY BECOME AVAILABLE.
9. ROLL OF ARCHITECT DURING CONSTRUCTION: THE ARCHITECT WILL NOT ACT AS THE OWNER'S REPRESENTATIVE DURING CONSTRUCTION. ARCHITECT WILL ADVISE AND CONSULT WITH OWNER. ARCHITECT WILL OBSERVE CONSTRUCTION PER HIS/HER
AGREEMENT WITH OWNER AND RENDER INTERPRETATIONS NECESSARY FOR THE PROPER EXECUTION OR PROGRESS OF THE WORK IN ACCORDANCE WITH THE INTENT OF THE PLANS AND SPECIFICATIONS. ARCHITECT WILL NOT BE RESPONSIBLE OR HAVE
CONTROL OR CHARGE OVER THE ACTS OR OMISSIONS, CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS, OF THE CONTRACTOR, SUB-CONTRACTORS, OR ANY OF THEIR AGENTS OR
EMPLOYEES, OR ANY OTHER PERSONS PERFORMING ANY OF THE WORK. ANY VERBAL INSTRUCTION OR AUTHORIZATION THAT IS CONFIRMED BY LETTER, MEETING NOTE, MEMORANDA, OR THE LIKE, (WITH A COPY SENT TO THE OWNER, OR THE OWNER'S
REPRESENTATIVE) & THERE IS NO EXCEPTION TAKEN WITHIN (10) CALENDAR DAYS, SHALL BE DEEMED EQUIVALENT TO RECEIPT OF WRITTEN INSTRUCTION, APPROVAL AND AUTHORIZATION FROM THE OWNER.
10. A.I.A. GENERAL CONDITIONS: THE CURRENT GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION PUBLISHED BY THE AMERICAN INSTITUTE OF ARCHITECTS SHALL APPLY AS THOUGH IT WERE PART OF THESE DOCUMENTS UNLESS SPECIFICALLY
MODIFIED IN THE OWNER/CONTRACTOR AGREEMENT. A COPY OF SAID GENERAL CONDITIONS MAY BE OBTAINED FROM THE ARCHITECT UPON REQUEST. THE NOTES CONTAINED IN THESE "GENERAL NOTES" ON THIS SHEET ARE INTENDED TO SUMMARIZE AND
COMPLIMENT THE A.I.A. GENERAL CONDITIONS. THE A.I.A. GENERAL CONDITIONS SHALL TAKE PRECEDENCE OVER THESE NOTES SHOULD A CONFLICT IN WORDING OCCUR.
11. EXTRAS: OWNER MAY ORDER EXTRA WORK OR MAKE CHANGES BY ALTERING, ADDING TO OR DEDUCTING FROM THE WORK, THE CONTRACT SUM BEING ADJUSTED TO THE MUTUAL SATISFACTION OF THE OWNER AND CONTRACTOR. BEFORE ANY CHANGES
ARE BEGUN, THE ADDED OR DEDUCTED SUM SHALL BE PRESENTED TO OWNER IN WRITING FOR APPROVAL.
12. SUBSTITUTIONS: SUBSTITUTIONS OF MATERIALS OR METHODS PROPOSED BY THE CONTRACTOR OR HIS SUB-CONTRACTORS CONTRARY TO DRAWINGS AND SPECIFICATIONS SHALL BE SUBMITTED TO ARCHITECT IN WRITING FOR APPROVAL OR DENIAL. IF
MORE THAN ONE MANUFACTURER IS SPECIFIED IN THE PLANS OR SPECIFICATIONS, IT SHALL BE THE CONTRACTOR'S OPTION TO SELECT THE ONE WHICH HE MAY DESIRE. IF MORE THAN ONE FINISH OR STYLE IS AVAILABLE IN THE ITEM SPECIFIED, CONTRACTOR
SHALL BE OBLIGATED TO NOTIFY ARCHITECT VERBALLY AND IN WRITING OF THIS FACT FOR ARCHITECT'S AND OWNER'S DECISION. WHERE THE TERM "OR EQUAL" IS USED IN DRAWINGS OR SPECS IT SHALL BE UNDERSTOOD THAT THE REFERENCE IS MADE
SUBJECT TO THE RULING AND JUDGMENT OF THE ARCHITECT AND SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW AND APPROVAL. ACTUAL SAMPLES OF THE SUBSTITUTIONS SHALL ALSO BE SUBMITTED TO THE ARCHITECT FOR REVIEW AND APPROVAL.
13. INSURANCE: CONTRACTOR SHALL CARRY GENERAL LIABILITY INSURANCE WITH BROAD FORM PROPERTY DAMAGE ENDORSEMENT AND CONTINGENT LIABILITY ENDORSEMENT. OWNER AND ARCHITECT SHALL BE LISTED AS ADDITIONAL INSURERS UNDER
THE POLICY WITH WAIVER OF SUBROGATION. CONTRACTOR SHALL FURNISH OWNER WITH A CERTIFICATE OF INSURANCE WITH A 30 DAY NOTICE OF CANCELLATION. OWNER SHALL OBTAIN A BUILDER'S RISK POLICY WITH ARCHITECT NAMED AS AN ADDITIONAL
INSURED WITH WAIVER OF SUBROGATION.
14. SCOPE OF DRAWINGS AND SPECIFICATIONS: THESE DRAWINGS AND SPECIFICATIONS SHALL BE INTENDED TO SHOW AND DESCRIBE DETAILS FOR A CONSTRUCTIBLE BUILDING. PARTS AND DETAILS NOT FULLY SHOWN OR DESCRIBED SHALL BE DETAILED
AND EXECUTED ACCORDING TO STANDARD FIRST CLASS PRACTICE AND IN SIMILAR MANNER AND SPIRIT OF THE DETAILS WHICH ARE SHOWN ON THE DRAWINGS AND/OR DESCRIBED IN THE PROJECT MANUAL. IF CONTRACTOR OR SUB-CONTRACTOR FINDS ANY
DETAILS WHICH, IN HIS OPINION, ARE UNSOUND, UNSAFE, OR NOT WATERPROOF, IT IS HIS DUTY TO NOTIFY ARCHITECT IN WRITING OF THIS FACT. IF WORK IS PERFORMED AS DETAILED, IT WILL BE ASSUMED THAT THERE ARE NO OBJECTIONS TO THE DETAIL.
ACCURACY OF ALL DIMENSIONS SHALL BE CHECKED. NO EXTRA COMPENSATION WILL BE ALLOWED FOR DIFFERENCE BETWEEN ACTUAL DIMENSIONS AND THOSE INDICATED ON THE DRAWINGS. IN USING THESE PLAN FOR BIDDING OR CONSTRUCTION
PURPOSES, ALL CONTRACTORS ARE REQUIRED TO REVIEW AND TREAT THEM AS A WHOLE IN ORDER TO IDENTIFY ALL REQUIREMENTS THAT DIRECTLY OR INDIRECTLY AFFECT THEIR PORTION OF THE WORK, EVEN REQUIREMENTS LOCATED IN SECTIONS
DESIGNATED AS APPLICABLE TO OTHER TRADES. IN CASE OF CONFLICTS, THE AFFECTED CONTRACTOR IS REQUIRED TO EITHER OBTAIN DIRECTION FROM AN APPROPRIATE REPRESENTATIVE OF THE OWNER, OR OTHERWISE TO APPLY THE MORE STRINGENT
STANDARD. THESE PLANS ARE INTENDED TO SET FORTH THE REQUIREMENTS FOR CONSTRUCTION IN ONLY AN INDUSTRY-STANDARD LEVEL OF QUALITY AND DETAIL, AND THEY ARE INTENDED TO BE SUPPLEMENTED BY APPROPRIATE REQUESTS FOR
CLARIFICATION AND INFORMATION. ERRORS AND OMISSIONS ARE TO BE EXPECTED AND ANTICIPATED, AND ALL CONTRACTORS ARE REQUIRED TO CAREFULLY REVIEW THESE PLANS FOR ERRORS AND OMISSIONS AND TO BRING THESE ERRORS AND OMISSIONS
TO THE ATTENTION OF A APPROPRIATE OWNER & ARCHITECT IN WRITING IN A TIMELY MANNER; AND ANY CONTRACTOR WHO FAILS TO DO SO BEFORE BIDDING OR OTHERWISE PROCEEDING ASSUMES THE RISK OF ANY CONSEQUENCES. SCALED DIMENSIONS
SHOULD BE CONSIDERED ONLY APPROXIMATE; AND IN ANY DIMENSIONS BEFORE PROCEEDING WITH ANY AFFECTED PROCUREMENT, FABRICATION OR CONSTRUCTION. SCHEMATIC PLANS ARE INTENDED ONLY TO DEMONSTRATE THE RELATIONSHIP AMONG
COMPONENT PARTS, AND NOT TO DEPICT SPECIFIC LOCATIONS (E.G. SCHEMATIC ELECTRICAL PLANS).
15. DIMENSIONS ON DRAWINGS: FIGURED DIMENSIONS SHALL BE FOLLOWED IN PREFERENCE TO SCALE, AND DETAIL DRAWINGS IN PREFERENCE TO SMALL SCALE DRAWINGS. SUB-CONTRACTOR AND CONTRACTOR SHALL CHECK ACCURACY OF ALL
DIMENSIONS IN THE FIELD PRIOR TO ANY WORK BEING CONSTRUCTED OR MATERIALS OR PRODUCTS FABRICATED OR ORDERED. SPECIFICATIONS AND WRITTEN NOTES AND SCHEDULES ON DRAWINGS SHALL BE FOLLOWED IN PREFERENCE TO INFORMATION
FURNISHED IN THE FORM OF LINE DRAWINGS. DETAILED DRAWINGS FURNISHED DURING CONSTRUCTION OR APPROVED BY CONTRACTOR OR ARCHITECT ARE TO BE CONSIDERED EXPLANATORY AND NOT AS CHANGES TO DRAWINGS AND SPECIFICATIONS.
NOTES, FIGURES AND DETAILS ON SAID DRAWINGS SHALL BE FOLLOWED AND EXECUTED AS IF PART OF THESE DOCUMENTS. DRAWINGS ARE NOT TO BE SCALED UNLESS PERMITTED BY THE ARCHITECT. DIMENSIONS SHALL GOVERN. ALL EXTERIOR
DIMENSIONS ARE BASED ON NOMINAL SIZES OF MEMBERS AND ARE GIVEN TO THE OUTER FACE OF SUCH MEMBERS, UNLESS OTHERWISE NOTED ON DRAWINGS. INTERIOR PARTITIONS ARE DIMENSIONED FROM FACE OF STRUCTURE TO FACE OF STRUCTURE
UNLESS OTHERWISE NOTED ON DRAWINGS. WHERE DIMENSION IS LABELED "CLEAR" IT IS TAKEN FROM THE FACE OF FINISH TO FACE OF FINISH OF EACH MATERIAL. PLUS OR MINUS (+/-) DIMENSIONS SHALL NOT VARY BY MORE THAN 2" WITHOUT APPROVAL
BY ARCHITECT. WALL ANGLES ARE EITHER 90° OR 45° UNLESS NOTED OTHERWISE.
16. SUBMITTALS, MEETING NOTES, BULLETINS, AND MEMOS: SUBMITTALS WILL BE REVIEWED BY THE ARCHITECT, IF AT ALL, ONLY PURSUANT TO THE INDUSTRY-STANDARD PROTOCOL SET FORTH IN AIA DOCUMENT A201-2017; AND IN NO EVENT WILL THE
SUBMITTAL REVIEW PROCESS RELIEVE OR LESSEN THE SUBMITTING CONTRACTOR'S RESPONSIBILITY FOR AN INAPPROPRIATE SUBMITTAL. ARCHITECT, FROM TIME TO TIME, WILL ISSUE CONSTRUCTION NOTES OR MEMOS REGARDING CONSTRUCTION ISSUES
THAT HAVE ARISEN SINCE THE DRAWINGS AND SPECIFICATIONS WERE COMPLETED. CONTRACTOR SHALL REVIEW THESE WRITTEN DOCUMENTS AND INCORPORATE THEM INTO THE PROJECT. ANY QUESTIONS OR OBJECTIONS AS TO THE INTENT OF THE WRITTEN
DOCUMENT ITEMS WILL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT FOR DISCUSSION AND OR CLARIFICATION. ANY ITEM THAT RESULTS IN A CHANGE TO THE COST OR TIMING OF THE PROJECT SHALL BE BROUGHT TO THE IMMEDIATE
ATTENTION OF THE OWNER & ARCHITECT PRIOR TO EXECUTING. CONTRACTOR SHALL SUBMIT FABRICATION SHOP DRAWINGS TO THE ARCHITECT FOR APPROVAL PRIOR TO ORDERING AND/OR FABRICATION. CONTRACTOR SHALL SUBMIT MANUFACTURER'S CUTS
FOR ALL FIXTURES AND EQUIPMENT CALLED FOR ON THE CONSTRUCTION DOCUMENTS TO ARCHITECT INCLUDING BUT NOT LIMITED TO LIGHT FIXTURES, HARDWARE, PLUMBING FIXTURES, KITCHEN EQUIPMENT, ETC. BY SUBMITTING SHOP DRAWINGS AND
PRODUCT DATA, THE CONTRACTOR REPRESENTS THAT HE/SHE HAS VERIFIED FIELD CONDITIONS, DIMENSIONS AND RELATED CONSTRUCTION AND HAS COORDINATED THE SUBMISSION CONSTRUCTION WITH THE REQUIREMENTS OF ALL OTHER RELATED WORK IN
THE CONSTRUCTION DOCUMENTS. ALL SHOP DRAWINGS AND CUTS MARKED "REVIEWED" BY ARCHITECT, ARE FOR VERIFICATION OF ADHERENCE TO THE DESIGN INTENT ONLY. THE CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR ALL MEANS AND METHODS
AND ERRORS AND OMISSIONS ON THEIR DRAWINGS. CONTRACTOR TO SUBMIT A COMPLETE SHOP DRAWINGS AND OR SUBMITTAL FOR APPROVAL BEFORE COMMENCING FABRICATION AND/OR INSTALLATION OF ALL APPLICABLE ITEMS. ALL SHOP DRAWINGS
DIMENSIONS SHALL BE FIELD VERIFIED, REVIEWED AND APPROVED BY CONTRACTOR BEFORE SUBMITTAL. SHOP DRAWINGS WHICH ARE INCOMPLETE OR LACKING SUFFICIENT INFORMATION WILL BE RETURNED WITHOUT REVIEW. SUBMIT SAMPLES FOR INITIAL
SELECTION PURPOSES OF ACTUAL VENEERS SHOWING A FULL RANGE OR GRAIN VARIATION, FINISH AND PATTERNS PROPOSED. SUBMIT SAMPLES AS REQUIRED UNTIL APPROVED BY ARCHITECT. SAMPLES SHALL BE 12" X 12" MIN., ONE UNIT OF EACH TYPE
AND FINISH.
17. ERRORS AND OMISSIONS: ERRORS OR OMISSIONS WHICH APPEAR ON THE DRAWINGS, IN SPECIFICATIONS OR OTHER CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT BY THE CONTRACTOR AND TO THE
CONTRACTOR BY THE SUB-CONTRACTOR IN WRITING. IN EVENT OF FAILURE OF SUB-CONTRACTOR TO GIVE SUCH WRITTEN NOTIFICATION BEFORE CONSTRUCTION OR FABRICATIONS OF THE WORK, HE WILL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY SUCH
ERRORS OR OMISSIONS AND THE COSTS OF RECTIFYING SAME. HOWEVER, DRAWINGS AND SPECIFICATIONS ARE COMPLEMENTARY AND WORK CALLED FOR ON ONE AND NOT THE OTHER SHALL BE PROVIDED AS THOUGH FULLY SET FORTH IN BOTH.
18. BARRICADES: CONTRACTOR SHALL ERECT AND PROPERLY MAINTAIN AT ALL TIMES AS REQUIRED BY CONDITIONS AND PROGRESS OF THE WORK, ALL NECESSARY PROTECTIVE BARRICADES, FENCES AND OTHER SAFEGUARDS FOR THE PROTECTION OF THE
WORKERS AND THE PUBLIC. THESE BARRICADES SHALL BE CONSTRUCTED AND BE LOCATED AS SHALL BE DETERMINED BY LOCAL AUTHORITIES AND CODES.
19. TEMPORARY BRACING: AT ALL TIMES DURING CONSTRUCTION ACTIVITIES OR ERECTION OF PROJECT OR ITS COMPONENT PARTS, PRIOR TO COMPLETION OF THE STRUCTURAL FRAME OR REPLACEMENT AND PERMANENT CONNECTION OF COMPONENT
MEMBERS TO THE STRUCTURAL FRAME, SUB-CONTRACTORS SHALL PROVIDE, INSTALL AND MAINTAIN PROPERLY DESIGNED AND CONSTRUCTED TEMPORARY BRACING OF ADEQUATE STRENGTH TO PREVENT DISLOCATION, DISTORTION, CRACKING, FALLING OFF,
OR ANY OTHER DAMAGE TO WORK OR ANY OF ITS COMPONENT PARTS DUE TO FORESEEABLE NORMAL AS WELL AS NOT FORESEEABLE EXCESSIVE WIND AND EARTHQUAKE FORCES WITHOUT ADDITIONAL COST TO OWNER. CONTRACTOR AND HIS
SUBCONTRACTORS SHALL, AT THEIR EXPENSE, REPLACE OR REPAIR, AS DIRECTED, DAMAGED PORTIONS OF THEIR WORK OR COMPONENT PARTS.
20. TOXIC SUBSTANCES REMOVAL: PRIOR TO ANY WORK BEING PERFORMED, WHENEVER THERE ARE EXISTING STRUCTURES TO BE REMOVED OR ALTERED, CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION AND REMOVAL OF ANY TOXIC MATERIALS OR
SUBSTANCES AS REQUIRED BY THE STATE OF CALIFORNIA INCLUDING BUT NOT LIMITED TO ASBESTOS, LEAD PAINTS, MOLD, ETC. REMOVAL AND DISPOSAL SHALL FOLLOW STATE MANDATED METHODS, PROCEDURES, DOCUMENTATION AND APPLICATION
REQUIREMENTS.
21. NO CHANGES ARE TO BE MADE ON THESE PLANS WITHOUT THE KNOWLEDGE OR CONSENT OF THE ARCHITECT/ ENGINEER WHOSE SIGNATURE APPEARS HERON.
22. NO FRAMING OF ANY TYPE TO BE CONCEALED PRIOR TO INSPECTION BY GOVERNING AGENCIES.
23. REFERENCES TO ANY DETAIL OR DRAWINGS IS FOR CONVENIENCE ONLY AND DOES NOT LIMIT THE APPLICATION OF SUCH DETAIL OR DRAWINGS.
24. USE 2X6 MINIMUM STUDS FOR PLUMBING WALLS
25. MAINTENANCE INFORMATION: THE BUILDER SHALL PROVIDE TO THE BUILDING OWNER AT OCCUPANCY MAINTENANCE INFORMATION FOR ALL FEATURES, MATERIALS, COMPONENTS, AND MANUFACTURED INFORMATION FOR ALL FEATURES, MATERIALS, AND
COMPONENTS AND MANUFACTURED DEVICES THAT REQUIRE ROUTINE MAINTENANCE FOR EFFICIENT OPERATION. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY STATED AND INCORPORATED ON A READILY ACCESSIBLE LABEL. THE LABEL MAY
BE LIMITED TO IDENTIFYING, BY TITLE AND/OR PUBLICATION NUMBER, THE OPERATION AND MAINTENANCE MANUAL FOR THAT PARTICULAR MODEL AND TYPE OF FEATURE, MATERIAL, COMPONENT, OR MANUFACTURED DEVICE. (SEE CALGREEN NOTES FOR
ADDITIONAL REQUIREMENTS OF OPERATION & MAINTENANCE MANUAL)
26. GENERAL CONTRACTOR, CONTRACTORS, SUB-CONTRACTORS AND BUILDERS TO COORDINATE ALL ENGINEERING AND MECHANICAL DRAWINGS WITH ARCHITECTURAL DRAWINGS BEFORE PROCEEDING WITH WORK. IF DISCREPANCIES ARE APPARENTLY
OBSERVED OR INFORMATION APPARENTLY IS THOUGHT TO BE MISSING, NOTIFY ARCHITECT WITHIN 24 HOURS WITH SKETCH, DRAWING, PDF, PHOTOCOPIES WITH LEGIBLE HANDWRITTEN NOTES AND/OR WRITING (FAX, EMAIL OR CORRESPONDENCE). IF CONFLICT
WITH EXISTING CONDITIONS, PROVIDE DOCUMENTATION (PHOTOS, SKETCHES, DWGS) OF EXISTING CONDITIONS AND SUGGEST PROPOSAL(S) FOR SOLUTION (SKETCH, DRAWING, AND/OR WRITING). IN CASE OF ANY DISCREPANCIES, THE ARCHITECT IS THE SOLE
INTERPRETER OF THE CONTRACT DOCUMENTS.
27. CONTRACTOR SHALL NOTIFY ARCHITECT FOR CLARIFICATION PRIOR TO BIDDING OF ANY DISCREPANCIES BETWEEN ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS. BID SHALL BE BASED ON THE MOST STRINGENT REQUIREMENT.
28. CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT OF ANY UNEXPECTED OR UNKNOWN FIELD CONDITIONS, ERRORS, OMISSIONS, OR DISCREPANCIES IN THE DRAWINGS, PROJECT MANUAL, OR CONTRACT DOCUMENTS PRIOR TO PROCEEDING WITH
THE WORK OR SHOP FABRICATIONS.
29. CONTRACTOR SHALL PREPARE AND MAINTAIN ALL CONSTRUCTION, AND SURROUNDING AREAS, FREE OF DEBRIS OR HAZARDOUS MATERIALS AT ALL TIMES. CONTRACTOR SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT DUST FROM RISING.
30. CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR AND/OR THE REPLACEMENT OF ANY ITEMS DAMAGED DURING CONSTRUCTION OR CLEAN-UP. ANY DAMAGE TO EXISTING STRUCTURES DURING THE CONSTRUCTION OR THE NEW WORK SHALL BE
REPAIRED TO EQUIVALENT OR BETTER THAN ORIGINAL CONDITION AT CONTRACTOR'S EXPENSE.
31. ALL OSHA REGULATIONS FOR CONSTRUCTION AREAS SHALL BE STRICTLY FOLLOWED. CONTRACTOR SHALL PROVIDE PROPER SAFEGUARDS DURING ALL PHASES OF CONSTRUCTION.
32. CONTRACTOR TO REMOVE, RELOCATE OR RE-ROUTE, AS NECESSARY, ELECTRICAL, TELEPHONE, WATER, SEWER, GAS OR ANY OTHER UTILITY LINES ENCOUNTERED AND SHALL COORDINATE THIS WORK WILL ALL LOCAL UTILITY COMPANIES.
33. CONTRACTOR SHALL PROVIDE TEMPORARY WEATHER PROTECTION FOR PORTIONS OF THE WORK THAT BECOME EXPOSED TO WEATHER AND SHALL BE RESPONSIBLE FOR DAMAGE CAUSED BY INSUFFICIENT PROTECTION.
34. CONTRACTOR TO OBTAIN WRITTEN APPROVAL FROM OWNER AND ARCHITECT PRIOR TO ANY CHANGES OR DEVIATION FROM CONTRACT DOCUMENTS.
35. CONTRACTOR SHALL SUBMIT IN WRITING ALL PROPOSALS FOR ADDITIONAL WORK TO THE OWNER FOR REVIEW AND APPROVAL. NO WORK IS TO PROCEED UNTIL AN AUTHORIZATION TO PROCEED; SIGNED BY THE ARCHITECT & OWNER'S REPRESENTATIVE IS
RETURNED TO THE GENERAL CONTRACTOR.
36. CONTRACTOR SHALL BE AWARE THAT SPECIFIC FIRE-RATED SEPARATION WITHIN THE BUILDING'S CONSTRUCTION IS REQUIRED BY CODE. THE USE OF SPECIFIC MATERIALS AND COMBINATION OF MATERIALS WITHIN FIRE RATED ASSEMBLIES, AS CALLED
FOR ON THE DRAWINGS AND SPECIFICATIONS, ARE FOR THE PURPOSE OF ACHIEVING THOSE REQUIRED FIRE SEPARATIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THAT ANY CHANGE IN MATERIAL THAT IS REQUESTED BY OR MADE BY THE
CONTRACTOR AND/OR ITS SUBCONTRACTORS, FROM THOSE MATERIALS DRAWN OR SPECIFIED, DOES NOT IN ANY WAY AFFECT OR LESSEN THE REQUIRED CONSTRUCTION ASSEMBLY INTEGRITY. SPECIFIC SEQUENCES OR METHODS OF ACHIEVING FIRE RATED
ASSEMBLIES REQUIRED BY A "U.L. NO." LISTING SHALL BE FOLLOWED WITHOUT DEVIATION, UNLESS OTHERWISE NOTED OR DETAILED.
69. CONTRACTOR TO FURNISH AND INSTALL ALL BLOCKING REQUIRED FOR WALL MOUNTED OR BRACED FIXTURES, MILLWORK, SHELVES, TOILET FIXTURES, AND ACCESSORIES OR 'BY OTHER' ITEMS DESCRIBED IN INTERIOR DESIGN AND ARCHITECTURAL
DRAWINGS. BLOCKING SHALL BE CONSTRUCTED TO SUPPORT THE IMPOSED LOAD.
37. ALL MANUFACTURED ARTICLES, MATERIALS AND EQUIPMENT SHALL BE SUPPLIED, INSTALLED, CONNECTED, ERECTED, USED, CLEANED AND CONDITIONED AS DIRECTED BY THE MANUFACTURERS AND REQUIRED BY CODE.
38. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY/COORDINATE UTILITY REQUIREMENTS FOR ALL OWNER/VENDOR FURNISHED EQUIPMENT, FIXTURES OR APPLIANCES.
39. CONTRACTOR SHALL PROVIDE ALL NECESSARY FASTENERS, SUPPORTS, SHIMMING, FLASH PATCHING, ETC. FOR THE PROPER INSTALLATION OF SUCH ITEMS AS DIRECTED BY THE MANUFACTURERS.
40. UPON COMPLETION OF THE PROJECT, THE CONTRACTOR SHALL GIVE TO THE OWNER A COMPLETE SET OF AS-BUILT CIVIL, LANDSCAPE, ARCHITECTURAL, MECHANICAL, PLUMBING, ELECTRICAL AND FIRE PROTECTION DRAWINGS ALONG WITH THE WRITTEN
GUARANTIES, OPERATION AND MAINTENANCE MANUALS OF ALL EQUIPMENT AND FINISHES INSTALLED. THE CONTRACTOR SHALL MAINTAIN A CURRENT SET OF AS-BUILT DRAWINGS AND SPECIFICATIONS. INFORMATION SHALL BE RECORDED BY CONTRACTOR
AS CONSTRUCTION PROGRESSES AND REVIEWED FOR COMPLETENESS AT EACH REQUISITION REQUEST.
41. CONTRACTOR IS RESPONSIBLE TO THOROUGHLY VACUUM CLEAN ALL CARPETED AREAS, CLEAN ALL FLOORING, MILLWORK, LIGHT FIXTURES, GLASS, ETC. AND UNCOVER AND VACUUM OUT ALL MECHANICAL UNITES AFTER THE WORK IS COMPLETED AND
MAINTAIN CLEAN CONDITIONS THROUGH THE TENANT'S MOVE-IN.
WATERPROOFING AND DAMPPROOFING NOTES:
R406.1 CONCRETE AND MASONRY FOUNDATION DAMPPROOFING
EXCEPT WHERE REQUIRED BY SECTION R406.2 TO BE WATERPROOFED, FOUNDATION WALLS THAT RETAIN EARTH AND
ENCLOSE INTERIOR SPACES AND FLOORS BELOW GRADE SHALL BE DAMPPROOFED FROM THE HIGHER OF (A) THE TOP OF THE
FOOTING OR (B) 6 INCHES (152 MM) BELOW THE TOP OF THE BASEMENT FLOOR, TO THE FINISHED GRADE. MASONRY WALLS
SHALL HAVE NOT LESS THAN 3/8-INCH (9.5 MM) PORTLAND CEMENT PARGING APPLIED TO THE EXTERIOR OF THE WALL. THE
PARGING SHALL BE DAMPPROOFED IN ACCORDANCE WITH ONE OF THE FOLLOWING:
1. BITUMINOUS COATING.
2. THREE POUNDS PER SQUARE YARD (1.63 KG/M2) OF ACRYLIC MODIFIED CEMENT.
3. ONE-EIGHTH-INCH (3.2 MM) COAT OF SURFACE-BONDING CEMENT COMPLYING WITH ASTM C887.
4. ANY MATERIAL PERMITTED FOR WATERPROOFING IN SECTION R406.2.
5. OTHER APPROVED METHODS OR MATERIALS.
EXCEPTION:PARGING OF UNIT MASONRY WALLS IS NOT REQUIRED WHERE A MATERIAL IS APPROVED FOR DIRECT
APPLICATION TO THE MASONRY.CONCRETE WALLS SHALL BE DAMPPROOFED BY APPLYING ANY ONE OF THE LISTED
DAMPPROOFING MATERIALS OR ANY ONE OF THE WATERPROOFING MATERIALS LISTED IN SECTION R406.2 TO THE EXTERIOR
OF THE WALL.
R406.2 CONCRETE AND MASONRY FOUNDATION WATERPROOFING
IN AREAS WHERE A HIGH WATER TABLE OR OTHER SEVERE SOIL-WATER CONDITIONS ARE KNOWN TO EXIST, EXTERIOR
FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE INTERIOR SPACES AND FLOORS BELOW GRADE SHALL BE
WATERPROOFED FROM THE HIGHER OF (A) THE TOP OF THE FOOTING OR (B) 6 INCHES (152 MM) BELOW THE TOP OF THE
BASEMENT FLOOR, TO THE FINISHED GRADE. WALLS SHALL BE WATERPROOFED IN ACCORDANCE WITH ONE OF THE
FOLLOWING:
1. TWO-PLY HOT-MOPPED FELTS.
2. FIFTY-FIVE-POUND (25 KG) ROLL ROOFING.
3. SIX-MIL (0.15 MM) POLYVINYL CHLORIDE.
4. SIX-MIL (0.15 MM) POLYETHYLENE.
5. FORTY-MIL (1 MM) POLYMER-MODIFIED ASPHALT.
6. SIXTY-MIL (1.5 MM) FLEXIBLE POLYMER CEMENT.
7. ONE-EIGHTH-INCH (3 MM) CEMENT-BASED, FIBER-REINFORCED, WATERPROOF COATING.
8. SIXTY-MIL (1.5 MM) SOLVENT-FREE LIQUID-APPLIED SYNTHETIC RUBBER.
ALL JOINTS IN MEMBRANE WATERPROOFING SHALL BE LAPPED AND SEALED WITH AN ADHESIVE COMPATIBLE WITH THE
MEMBRANE.
EXCEPTION: ORGANIC-SOLVENT-BASED PRODUCTS SUCH AS HYDROCARBONS, CHLORINATED HYDROCARBONS, KETONES AND
ESTERS SHALL NOT BE USED FOR ICF WALLS WITH EXPANDED POLYSTYRENE FORM MATERIAL. USE OF PLASTIC ROOFING
CEMENTS, ACRYLIC COATINGS, LATEX COATINGS, MORTARS AND PARGINGS TO SEAL ICF WALLS IS PERMITTED. COLD-SETTING
ASPHALT OR HOT ASPHALT SHALL CONFORM TO TYPE C OF ASTM D449. HOT ASPHALT SHALL BE APPLIED AT A TEMPERATURE
OF LESS THAN 200°F (93°C).
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE
NEAREST 1/8" AND INTERIOR PARTITIONS ARE DIMENSIONED FROM FACE OF STRUCTURE TO FACE OF STRUCTURE (F.O.S.)
U.N.O. -CONTACT ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
ROUGH FRAMING:
ALL EXTERIOR WALLS TO BE FRAMED W/. 2X6 STUD MIN. U.N.O.
USE 2X6 MINIMUM STUDS FOR PLUMBING WALLS
SECOND AND THIRD FLOOR PLYWOOD TO BE 1-1/8"
ENTIRE EXTERIOR TO BE SHEATHED WITH 1/2" PLYWOOD
DOORS AND WINDOWS WILL TYPICALLY BE RECESSED FROM EXTERIOR WALL PLANE. VERIFY ALL ROUGH OPENING
DIMENSIONS WITH DOOR AND WINDOW MFGR. ROUGH OPENING MAY NEED TO BE OVERSIZED TO ACCOUNT FOR ADDITIONAL
FRAMING. SEE SHT. AD-2.0 FOR TYP. RECESSED CONDITIONS.
DUCTS PENETRATION:
DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE
SHALL BE CONSTRUCTED OF A MINIMUM NO. 26 GAGE (0.48 MM) SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL
NOT HAVE OPENINGS INTO THE GARAGE (R302.5.2)
STAIRWAY ILLUMINATION:
1.INTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE TO ILLUMINATE THE LANDINGS AND TREADS.
THE LIGHT SOURCE SHALL BE CAPABLE OF ILLUMINATING TREADS AND LANDINGS TO LEVELS OF NOT LESS THAN 1 FOOT-
CANDLE (11 LUX) AS MEASURED AT THE CENTER OF TREADS AND LANDINGS. THERE SHALL BE A WALL SWITCH AT EACH
FLOOR LEVEL TO CONTROL THE LIGHT SOURCE WHERE THE STAIRWAY HAS SIX OR MORE RISERS. (R303.7)
EXCEPTION:A SWITCH IS NOT REQUIRED WHERE REMOTE, CENTRAL OR AUTOMATIC CONTROL OF LIGHTING IS
PROVIDED.
2.EXTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE TOP LANDING OF THE
STAIRWAY. EXTERIOR STAIRWAYS PROVIDING ACCESS TO A BASEMENT FROM THE OUTDOOR GRADE LEVEL SHALL BE
PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE BOTTOM LANDING OF THE STAIRWAY. (R303.8)
GARAGE FLOOR:
GARAGE FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTIBLE MATERIAL.THE AREA OF FLOOR USED FOR PARKING OF
AUTOMOBILES OR OTHER VEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS TO A DRAIN OR TOWARD
THE MAIN VEHICLE ENTRY DOORWAY. (R309.1)
PLUMBING:
1. ALL FIXTURES AND FITTINGS SHALL COMPLY WITH THE MAX FLOW RATE SET BY CALGREEN (CALIFORNIA GREEN BUILDING
STANDARD CODE) AND CALIFORNIA PLUMBING CODES. G.C. TO VERIFY PRIOR TO PURCHASE AND INSTALL OF ANY FIXTURE
AND FITTING
2. MAX. TEMP. OF 120° TO BE APPROVED BY THE USE OF PRESSURE BALANCE OR THERMOSTATIC MIXING VALVES TYP. IN
COMPLIANCE W/. ASSE 1070/ASME A112.1070/CSA B125.70 @ SHOWERS & TUBS.
3. MAX. TEMP. OF 110° TO BE APPROVED BY THE USE OF PRESSURE BALANCE OR THERMOSTATIC MIXING VALVES TYP. IN
COMPLIANCE W/. ASSE 1070/ASME A112.1070/CSA B125.70 @ BIDETS.
4. SUPPORT ALL WALL-HUNG FIXTURES WITH METAL SUPPORTING MEMBERS TO PREVENT ANY STRAIN TRANSMISSION TO
THE CONNECTIONS. FRAMING AFFIXED SUPPORTS FOR OFF-THE-FLOOR WATER CLOSETS WITH CONCEALED TANKS SHALL
COMPLY WITH ASME A112.6.2. SECURE FLUSH TANK AND SIMILAR APPURTENANCES WITH APPROVED NON-CORROSIVE SCREW
OR BOLTS. (CPC 402.5)
5. THE NET AREA OF THE SHOWER ENCLOSURE SHALL BE 1,024 SQ. INCHES (7.1 SQ. FT.) OR MORE IN THE CLEAR FLOOR AREA,
AND SHALL ALSO BE CAPABLE OF ENCOMPASSING A 30-INCH DIAMETER CIRCLE. (CPC 408.6)
6. THE WATER HEATER BURNER AND BURNER-IGNITION DEVICE TO BE AT LEAST 18-INCHES ABOVE THE FLOOR, IF LOCATED IN A
GARAGE AND IN ADJACENT SPACES THAT OPEN TO THE GARAGE. FOR WATER HEATER IN THE GARAGE OR OTHER AREAS
SUBJECT TO MECHANICAL DAMAGE PROVIDE A PROTECTIVE BARRIER OR ELEVATE THE APPLIANCE TO BE OUT OF THE NORMAL
PATH OF THE VEHICLE. (CPC 507.13)
7. ANCHOR OR STRAP THE WATER HEATER(S) TO RESIST HORIZ. DISPLACEMENT DUE TO THE EARTHQUAKE. STRAPPING
SHOULD BE AT THE UPPER AND LOWER ONE THIRD (1/3) POINTS OF THE APPLIANCE HEIGHT. MAINTAIN A MIN. 4-INCHES
ABOVE THE CONTROLS WITH STRAPPING AT LOWER POINT.
MATERIALS & FINISHES:
1. WALLS COVERINGS AND FLOOR OF SHOWERS AND BATHTUBS WITH A SHOWER HEAD SHALL BE OF CEMENT PLASTER, TILE,
OR APPROVED EQUAL NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS THAN 72-INCHES ABOVE THE FLOOR. PROVIDE
CEMENT BOARD, CEMENT PLASTER BACKING, OR TILE BACKBOARD FOR TILE FINISH. (CRC R307.2)
2. INSTALL MIN. 5/8" TYPE 'X' MOISTURE & MOLD RESISTANT GYPSUM WALL BOARD IN ALL BATHROOMS AND KITCHENS.
FIREPLACES:
1. FACTORY-BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR COMPONENTS SHALL BE LISTED AND INSTALLED IN
ACCORDANCE WITH THEIR LISTING AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. (CRC R1004.1)
2. FACTORY BUILT WOOD BURNING FIREPLACES SHALL BE QUALIFIED AT THE U.S. EPA’S VOLUNTARY FIREPLACE PROGRAM
PHASE 2 EMISSIONS LEVEL. (CRC 1004.1.1)
3. DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT THE TERMINATION OF FACTORY-BUILT CHIMNEYS EXCEPT WHERE
SUCH SHROUDS ARE LISTED AND LABELED FOR USE WITH THE SPECIFIC FACTORY-BUILT CHIMNEY SYSTEM AND ARE
INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. (CRC R1005.2 & CMC 802.5.1.1 & CMC
802.5.4.3)
4. HORIZONTAL OPENINGS ARE NOT ALLOWED, FOR EXHAUST VENTS, IN WALLS CLOSER THAN 3 FEET TO A PROPERTY LINE.
(TABLES R302.1(1)&(2)). HORIZONTAL VENT CAPS SHALL BE 2 FEET CLEAR FROM PROPERTY LINES.
5. EXHAUST OPENINGS SHALL NOT BE DIRECTED ONTO WALKWAYS. (R303.5.2)
6. SOLID FUEL BURNING FIREPLACES (IF PERMISSIBLE):
A. PROVIDE A PERMANENTLY ANCHORED GASEOUS FUEL BURNING PAN TO THE FIREBOX OF A SOLID
FUEL BURNING FIREPLACE.
B. SOLID FUEL BURNING FIREPLACE MUST COMPLY WITH THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES.
C. CHIMNEY SHALL EXTEND AT LEAST 2 FT. HIGHER THAN ANY PORTION OF THE BUILDING WITHIN 10 FT., BUT SHALL
NOT BE LESS THAN 3 FT. ABOVE THE HIGHEST POINT WHERE THE CHIMNEY PASSES THROUGH THE ROOF. (CRC R1003.9)
D. LIQUID FUELED FIREPLACES ARE NOT ALLOWED FOR INTERIOR USE.
7. ANY INSTALLED GAS FIREPLACE SHALL BE DIRECT VENT SEALED-COMBUSTION PER CAL GREEN SECTION 4.503.
POOL:
1. PROVIDE AN ALARM FOR DOORS AND WINDOWS WITH SILL HEIGHTS LESS THAN 60-INCHES ABV.F.F. OF THE DWELLING THAT
FORMS A PART OF THE POOL ENCLOSURE. THE ALARM SHALL BE LISTED AS A WATER HAZARD ENTRANCE ALARM IN
ACCORDANCE WITH UL 2017. THE DEACTIVATION SWITCH SHALL BE AT LEAST 60" ABOVE THE FLOOR IF THE RESIDENCE IS NOT
REQUIRED TO BE ACCESSIBLE. (CBC 3109 & ISPSC 305.4)
2. SUCTION OUTLETS SHALL BE DESIGNED AND INSTALLED WITH SUCTION ANTIENTRAPMENT GRATE IN ACCORDANCE WITH
ANSI/APSP-16 PER CBC 3109 SECTION (B) OF 115928. SUCTION ENTRAPMENT AVOIDANCE FOR POOL AND SPA SHALL BE
PROVIDED IN ACCORDANCE WITH APSP-7 PER ISPSC SECTION 310.
3. PROVIDE POWER SAFETY COVER IN COMPLIANCE WITH ASTM F1346-91 FOR POOL & SPA (CBC 3109 SECTION (3) OF 115922
& ISPSC 305).
4. POOL ENCLOSURE FENCE SHALL BE 60-INCHES MIN. ABV. FS/NG MEASURED ON THE SIDE THAT FACES AWAY FROM
SWIMMING POOL W/. MAX VERTICAL CLEARANCE OF 2-INCHES BETWEEN FS/NG AND BOTTOM OF THE FENCE/BARRIER
MEASURED ON THE SIDE OF FENCE THAT FACES AWAY FROM SWIMMING POOL. OPENING, GAP, AND VOID IN ENCLOSURE
FENCE OR GATE SHALL NOT ALLOW THE PASSAGE OF 4-INCHES DIAMETER SPHERE OR LARGER. OUTSIDE SURFACE (FACING
AWAY FROM SWIMMING POOL) OF THE POOL ENCLOSURE INCLUDING THE GATE TO BE FREE OF PROTRUSIONS, CAVITIES, OR
OTHER PHYSICAL CHARACTERISTICS THAT WOULD SERVE AS HANDHOLDS OR FOOTHOLDS WHICH COULD ENABLE A CHILD FIVE
YEARS OLD OR YOUNGER TO CLIMB OVER. (CBC 3109 & ISPSC 305)
WOOD OR WOODBASED PRODUCTS NOTE:
WOOD OR WOODBASE PRODUCT SHALL BE OF A NATURAL DURABLE OR PRESERVATIVE-TREADED WOOD IN ACCORDANCE WITH
AWPA U1 FOR THE SPECIES, PRODUCT, PRESERVATIVE AND END USE IN THE FOLLOWING LOCATIONS:
1. WOOD JOISTS OR THE BOTTOM OF A WOOD STRUCTURAL FLOOR WHEN CLOSER THAN 18 INCHES (457 MM) OR WOOD
GIRDERS WHEN CLOSER THAN 12 INCHES (305 MM) TO THE EXPOSED GROUND IN CRAWL SPACES OR UNEXCAVATED AREA
LOCATED WITHIN THE PERIPHERY OF THE BUILDING FOUNDATION.
2. WOOD FRAMING MEMBERS THAT REST ON CONCRETE OR MASONRY EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8
INCHES (203 MM) FROM THE EXPOSED GROUND.
3. SILLS AND SLEEPERS ON A CONCRETE OR MASONRY SLAB THAT IS IN DIRECT CONTACT WITH THE GROUND UNLESS
SEPARATED FROM SUCH SLAB BY AN IMPERVIOUS MOISTURE BARRIER.
4. THE ENDS OF WOOD GIRDERS ENTERING EXTERIOR MASONRY OR CONCRETE WALLS HAVING CLEARANCES OF LESS THAN
1/2 INCH (12.7 MM) ON TOPS, SIDES AND ENDS.
5. WOOD SIDING, SHEATHING AND WALL FRAMING ON THE EXTERIOR OF A BUILDING HAVING A CLEARANCE OF LESS THAN 6
INCHES (152 MM) FROM THE GROUND OR LESS THAN 2 INCHES (51 MM) MEASURED VERTICALLY FROM CONCRETE STEPS,
PORCH SLABS, PATIO SLABS AND SIMILAR HORIZONTAL SURFACES EXPOSED TO THE WEATHER.
6. WOOD STRUCTURAL MEMBERS SUPPORTING MOISTURE-PERMEABLE FLOORS OR ROOFS THAT ARE EXPOSED TO THE
WEATHER, SUCH AS CONCRETE OR MASONRY SLABS, UNLESS SEPARATED FROM SUCH FLOORS OR ROOFS BY AN IMPERVIOUS
MOISTURE BARRIER.
7. WOOD FURRING STRIPS OR OTHER WOOD FRAMING MEMBERS ATTACHED DIRECTLY TO THE INTERIOR OF EXTERIOR
MASONRY WALLS OR CONCRETE WALLS BELOW GRADE EXCEPT WHERE AN APPROVED VAPOR RETARDER IS APPLIED BETWEEN
THE WALL AND THE FURRING STRIPS OR FRAMING MEMBERS.
WASHER & DRYER NOTE:
AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –PROVIDE POWER , GAS, WATER SUPPLY & DRAINAGE AS REQUIRED -THE
CLOTHES DRYERS VENT SHALL BE OF A RIGID METALLIC MATERIAL AND HAVE A BACKDRAFT DAMPER (CMC 504.4) AND SHALL
NOT EXCEED 14-FEET IN OVERALL LENGTH WITH MAX. OF TWO (2) 90-DEGREE ELBOW, SUBTRACT 2-FEET FOR EACH
ADDITIONAL 90-DEGREE ELBOW. (CMC 504.4.2.1) DRYER VENT TERMINATION MUST BE 3-FEET FROM OPENINGS INTO THE
BUILDING (DOORS AND OPERABLE WINDOWS), 10-FEET FROM FORCED AIR INLET, AND 3-FEET FROM PROPERTY LINE (NOT TO
DISCHARGE ONTO A PUBLIC WALKWAY). (CMC 502.2.1) IF DRYER LOCATED IN A CLOSET PROVIDE A MIN. 100 SQ.IN. OPENING
IN THE CLOSET DOOR. (CMC. 504.4.1)
*HERS VERIFICATION REQUIRED-REFERENCE T-24.1
&AND
.ANGLE
@ AT
C.L. CENTERLINE
∅DIAMETER, ROUND
.PERPENDICULAR
# POUND OR NUMBER
A.B.ANCHOR BOLT
ABV. ABOVE
A/C.AIR CONDITIONING
A.C.ASPHALT CONCRETE
ACOUS ACOUSTICAL
A.D.AREA DRAIN
ADH. ADHESIVE
ADJ. ADJUSTABLE, ADJACENT
AL.ALUMINUM
ALT.ALTERNATE
ANOD.ANODIZED
A.P.ACCESS PANEL
APPX. APPROXIMATE
APPV'D. APPROVED
ARCH.ARCHITECTURAL,ARCHITECT
ASB. ASBESTOS
ASSY. ASSEMBLY
AUTO.AUTOMATIC
B. BATHROOM
BD. BOARD
BEL. BELOW
BET. BETWEEN
BIT. BITUMINOUS
BLDG.BUILDING
BLK. BLOCK
BLK'G.BLOCKING
BM. BEAM
B.O.BY OWNER, BY OTHERS
BOT. BOTTOM
BR. BEDROOM
B.W. BACK OF WALL, BOTTOM OF WALL
CAB. CABINET
C.B.CATCH BASIN
C.B.C. CALIFORNIA BUILDING CODE
C.R.C. CALIFORNIA RESIDENTIAL CODE
CEM.CEMENT
C.G.CORNER GUARD
CHAN.CHANNEL
CHG.CHANGE
C.I. CAST IRON
C.J. CONTROL / CONSTRUCT./CEILING JOINT
CLG. CEILING
CLKG. CAULKING
CLR. CLEAR, CLEARANCE
CNTR.COUNTER
CONC.CONCRETE
COND.CONDITION
CONST. CONSTRUCT, CONSTRUCTION
CORR.CORRIDOR, CORROSIVE
CTSK. COUNTER SINK, COUNTERSUNK
CTR. CENTER
DBL. DOUBLE
DECO.DECORATIVE
DEPT. DEPARTMENT
DET. DETAIL
D.F.DRINKING FOUNTAIN, DOUGLAS FIR
DIA.DIAMETER
DIAG. DIAGONAL
DIM. DIMENSION
DN. DOWN
DR. DOOR
D.S.DOWNSPOUT
D.S.P. DRY STANDPIPE
DWG. DRAWING(S)
E. EXISTING, EAST, ENTRY, EACH
E.J. EXPANSION JOINT
ELEC. ELECTRIC, ELECTRICAL
ELEV. ELEVATOR
EMER.EMERGENCY
ENCL. ENCLOSED, ENCLOSURE
E.P.ELECTRICAL PANEL, END POINT
EQ. EQUAL
EQV. EQUIVALENT
EQUIP.EQUIPMENT
E.W. EACH WAY
EXH. EXHAUST
EXPO.EXPOSED
EXT. EXTERIOR
E.G.EXISTING GRADE
F.FIXED
F.A. FIRE ALARM
FAC. FACTORY
F.C.O. FLOOR CLEAN OUT
F.D.FLOOR DRAIN
FDN. FOUNDATION
F.E. FIRE EXTINGUISHER
F.E.C. FIRE EXTINGUISHER CABINET
F.G.FINISH GRADE
FIXT.FIXTURE
F.J. FLOOR JOIST
F.L. FLOW LINE
FLASH. FLASHING
FLR. FLOOR
FLUOR. FLUORESCENT
F.O.C. FACE OF CONCRETE/CURB
F.O.F. FACE OF FINISH
F.O.S. FACE OF STUD / STRUCTURE / SHEATHING
F.O.M.FACE OF MASONRY
FP. FIREPLACE
F.S. FLOOR SINK, FINISH SURFACE
FT.FOOT, FEET
FTG. FOOTING
FURR.FURRING
FUT. FUTURE
F.V. FIELD VERIFY
GA. GAUGE
GALV. GALVANIZED
G.B.GRAB BAR, GRADE BEAM
G.C.GENERAL CONTRACTOR
GEN.GENERAL
G.F.I.GROUND FAULT INTERRUPT
G.I. GALVANIZED IRON
G.L.B. GLU-LAM BEAM
GND.GROUND
GR. GRADE
GYP. GYPSUM
G.P.GRADE PLANE
H./HT. HIGH, HEIGHT
H.B.HOSE BIBB
H.C.HOLLOW CORE
HD. HARD, HEAD
HDR.HEADER
I.D. INTERIOR DESIGNER, INSIDE DIAMETER/DIMENSION
IN.INCH
INSUL.INSULATION
INT.INTERIOR
INV.INVERT/INVERTED
JAN. JANITOR
JT.JOINT
JST.JOIST
KIT. KITCHEN
L.LOW, LINEN
L.A. LANDSCAPED AREA
LAB. LABORATORY
LAM. LAMINATED
LAV. LAVATORY
LBS. POUNDS
LFA.LOAD FROM ABOVE
L.H. LEFT HAND
LKR. LOCKER
LT.LIGHT
LUM. LUMINOUS, LUMENS
MAINT. MAINTENANCE
MAS.MASONRY
MAT. MATERIAL
MAX.MAXIMUM
M.B.METAL BOLT
M.C. MEDICINE CABINET
MECH.MECHANICAL
MEMB.MEMBRANE
MTL. METAL
MFGR.MANUFACTURER
M.H. MANHOLE
MIN. MINIMUM
MIR. MIRROR
MISC. MISCELLANEOUS
M.O. MASONRY OPENING
MT. MOUNTED
MUL. MULLION
N. NEW, NORTH
NAT. NATURAL
N.I.C.NOT IN CONTRACT, CONTACT
N.G.NATURAL GRADE
NO. NUMBER
NOM.NOMINAL
N.T.S. NOT TO SCALE
O/.OVER
O.A.OVERALL
OBS. OBSCURE
O.C.ON CENTER
O.D.OUTSIDE DIAMETER, DIMENSION
O.F.D. OVERFLOW DRAIN
OFF. OFFICE
OPNG.OPENING
OPP. OPPOSITE
PERIM. PERIMETER
PL.PROPERTY LINE, PLATE
P.LAM. PLASTIC LAMINATE
PLAS. PLASTER
PLUMB. PLUMBING
PLYWD. PLYWOOD
PNT. PAINT(ED)
P.O.C. POINT OF CONTACT, CONNECTION
PR. PAIR
PROJ. PROJECTION
PSL. PARALLEL STRAND LAMINATE
PT. POINT
R.A.RETURN AIR
RAD. RADIUS
R.D.ROOF DRAIN
R.D.L. ROOF DRAIN LEADER
RECPT. RECEPTACLE
RECT. RECTANGLE, RECTANGULAR
REF. REFERENCE
REFR.REFRIGERATOR
REG.REGULAR, REGISTER
REINF. REINFORCE(D), REINFORCEMENT
REQ'D. REQUIRED
RESIL.RESILIENT
RET. RETAIN(ING), RETURN
RM. ROOM
R.O.ROUGH OPENING
R.R.ROOF RAFTER
RWD. REDWOOD
S. SOUTH
S.A.SUPPLY AIR
S.C.SOLID CORE
S.C.D. SEAT COVER DISPENSER
SCHED. SCHEDULE
S.D.SUBDRAIN, SOAP DISPENSER
SEC. SECTION
SEL. SELECT(ED)
SH. SHELF
SHT. SHEET
SHT'G.SHEATHING
SIM.SIMILAR
SIMP. SIMPSON
S.J. SOFFIT JOIST
S.S.STAINLESS STEEL
S.SK.SERVICE SINK
STA. STATION
STD. STANDARD
STL.STEEL
STOR.STORAGE
STRUCT. STRUCTURE, STRUCTURAL
SUSP. SUSPEND(ED)
SYM.SYMMETRICAL
SYS. SYSTEM
T.TREAD, TRASH
T.C.TOP OF CURB
T.CL. TIME CLOCK
TEL.TELEPHONE
TEMP.TEMPERED
TER. TERRAZZO
T & G TONGUE & GROOVE
THK. THICK, THICKNESS
T.P. TOP OF PAVING
T.PL. TOP OF PLATE
T.O.S. TOP OF STRUCTURE, SHEATHING, SLAB
TRANS. TRANSFORMER
T.S. TOP OF STEP
T.W.TOP OF WALL
TYP. TYPICAL
U. UNDER
U.B.C. UNIFORMBUILDING CODE
U.G.UNDERGROUND
U.L. UNDERWRITER'S LABORATORY
UNF. UNFINISHED
U.N.O.UNLESS NOTED OTHERWISE
UR. URINAL
V./VERT. VERTICAL
VENT. VENTILATION, VENTILATING
VER. VERIFY
V.T.R. VENT THROUGH ROOF
W. WEST, WIDTH, WASHER
W/.WITH
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
CONTRACT DOCUMENT NOTESAGENERAL NOTESBABBREVIATIONSC
01.28.22
ARCHITECTURAL
GENERAL NOTESMITCHELL RESIDENCETOM & KELLY MITCHELL
141 GALAXY DR.
NEWPORT BEACH, CA 92660
CDP FIRST CHECK
2631 WAVERLY DR.
NEWPORT BEACH, CA 92663
T-1.1
TBD
BRIAN JOWETT
NO. REVISION DATE
PA2022-027
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
01.28.22
SUPPLEMENTAL
DOC. & NOTESMITCHELL RESIDENCETOM & KELLY MITCHELL
141 GALAXY DR.
NEWPORT BEACH, CA 92660
CDP FIRST CHECK
2631 WAVERLY DR.
NEWPORT BEACH, CA 92663
T-1.2
TBD
BRIAN JOWETT
NO. REVISION DATE
PA2022-027
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
01.28.22
CALGREEN
STANDARDSMITCHELL RESIDENCETOM & KELLY MITCHELL
141 GALAXY DR.
NEWPORT BEACH, CA 92660
CDP FIRST CHECK
2631 WAVERLY DR.
NEWPORT BEACH, CA 92663
T-1.3
TBD
BRIAN JOWETT
NO. REVISION DATE
PA2022-027
N87°16'30"E 65.79'N19°17'32"W 111.95'N05°50'17"W 100.56'Δ=13°29'13" R=170.00' L=40.02'
WAVERL
Y
D
R
I
V
E
CL
ALLEY
LOT 48TRACT NO. 1014M.M. 33/31LOT 53TRACT NO. 1014M.M. 33/31LOT 49BASIS OF BEARINGS THE BASIS OF BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINEOF WAVERLY DRIVE HAVING A BEARING OF N87°13'40"E PER CR 2012-3505.VICINITY MAPBENCHMARK INFORMATION2631 WAVERLY DRIVE
NEWPORT BEACH, CA 92663
(APN: 049-183-33)
TOPOGRAPHIC MAP
1 1TITLE REPORT/EASEMENT NOTES2631 WAVERLY DRIVENEWPORT BEACH, CA 92663(APN: 049-183-33)NO TITLE REPORT PROVIDEDLEGAL DESCRIPTIONREAL PROPERTY SITUATED IN THE CITY OF NEWPORT BEACH,COUNTY OF ORANGE, STATE OF CALIFORNIA AND ISDESCRIBED AS FOLLOWS:LOT 48 IN TRACT NO. 1014, IN THE CITY OF NEWPORT BEACH,COUNTY OF ORANGE, STATE OF CALIFORNIA AS PER MAPRECORDED IN BOOK 33, PAGE 31 OF MISCELLANEOUS MAPS INTHE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY.LCEXISTING ELEVATIONLEGEND( )ACASPHALT PAVEMENTFOUND MONUMENTSEARCHED, FOUND NOTHING; SETNOTHINGFSFLFINISHED SURFACEFLOWLINEFFGFINISHED FLOOR GARAGECONCRETE SURFACET.B.M.TEMPORARY BENCHMARKSET ON TOP OF CURB ALONG WAVERLY DRIVE(TC)ELEVATION = 13.10 FEETHUNTINGTON BEACH, CALIFORNIA 92646PHONE:(714)488-5006 FAX:(714)333-4440
APEXLSINC@GMAIL.COMPAUL D. CRAFT, P.L.S. 8516 DATENOTE: SECTION 8770.6 OF THE CALIFORNIA BUSINESS AND PROFESSIONS CODESTATES THAT THE USE OF THE WORD CERTIFY OR CERTIFICATION BY ALICENSED LAND SURVEYOR IN THE PRACTICE OF LAND SURVEYING OR THEPREPARATION OF MAPS, PLATS, REPORTS, DESCRIPTIONS OR OTHER SURVEYINGDOCUMENTS ONLY CONSTITUTES AN EXPRESSION OF PROFESSIONAL OPINIONREGARDING THOSE FACTS OR FINDINGS WHICH ARE THE SUBJECT OF THECERTIFICATION AND DOES NOT CONSTITUTE A WARRANTY OR GUARANTEE,EITHER EXPRESSED OR IMPLIED.LICENSE RENEWAL DATE 12/31/22STATEOFCALI
FOR
N
IA
PAUL
DOMINICKCRAFTExp. 12/31/22No. 8516PROFESSI
ONALLANDSURVEYORFFFINISHED FLOORWATER METERWMEGEDGE OF GUTTERGAS METERGMCENTERLINETCTOP OF CURBGRAPHIC SCALESURVEYOR OR ENGINEER SHALL PERMANENTLY MONUMENT PROPERTYCORNERS OR OFFSETS BEFORE STARTING GRADING.PLEASE CALL PAUL CRAFT @ 714-488-5006 TO SCHEDULE.SURVEYOR'S NOTESBLOCK WALLBRICK SURFACENGNATURAL GROUNDBENCHMARK NO.: NB4-39-77DESCRIBED BY OCS 2002 - FOUND 3 3\4" OCS ALUMINUM BENCHMARK DISKSTAMPED "NB4-39-77", SET IN THE NORTHEAST CORNER OF A 4.3 FT. BY 4.8 FT.CONCRETE CATCH BASIN. MONUMENT IS LOCATED IN THE SOUTHEAST CORNEROF THE INTERSECTION OF BAYSIDE DRIVE AND HARBOR ISLAND DRIVE, 64.6 FT.EASTERLY OF THE CENTERLINE OF HARBOR ISLAND DRIVE AND 38 FT.SOUTHERLY OF THE CENTERLINE OF BAYSIDE DRIVE. MONUMENT IS SET LEVELWITH THE SIDEWALK.ELEVATION: 10.859 FEET (NAVD88), YEAR LEVELED: 2011ACU AIR CONDITION UNITCATV CABLE TV BOXWOODEN FENCE (WDF)MAILBOXMBPAPLANTER AREASCO SEWER CLEANOUTIRRIGATION CONTROL VALVEICVTFTOP OF FENCETGTOP OF GRATETWTOP OF WALLPA2022-027
PA2022-027
PA2022-027
PA2022-027
RmPA2022-027
UP
UP
N87°16'30"E 111.34' (111.23' TR.1014)HELD 9.6' ON PL PROD.CR21010-2166L O T 4 8
T R A C T N O . 1 0 1 4 M .M . 3 3 /3 1
L O T 5 3
T R A C T N O . 1 0 1 4
M .M . 3 3 /3 1
L O T 4 9
WAVERLY DRIVEALLEYN87°16'30"E 65.79'N 1 9°1 7'3 2 "W 11 1 .95 '
N05°50'17"W 100.56'
(1 3.15 )T C
(1 2.50 )F L
(1 3.11 )T C
(1 2 .4 8)FL
(1 3.10 )T C
(12 .4 9)FL
(1 3.11 )T C
(1 2 .4 4)FL
(13 .0 8)TC
(1 2.44 )F L
(14 .8 0)T W
(1 3 .9 2 )N G
(1 5 .0 4)TW
(1 4.60 )NG
(1 4.04 )T W
(1 3.10 )N G
(1 2.58 )
EG
(1 2.55 )
E G
(1 2 .5 4)
E G
(1 2.56 )
EG
(1 3 .0 5)
A C
(1 2.93 )
A C
(12 .8 6)
A C
(1 3 .9 1 )
NG
(3 9.60 )
R I D GE
(43 .9 3 )
CHI M N EY TO P
(4 2 .00)
C H IMNE Y T O P
(3 7 .5 5)
R ID G E
(2 5.52 )
R ID GE
(1 3 .6 3 )
NG
(1 4 .7 3 )
F F
(1 3.86 )
N G (1 3 .98 )
N G
(3 7.36 )
R I D GE
(1 3 .6 2)
NG
(3 7 .8 9)
CHI MNE Y TO P
(14 .6 5 )
FS
(3 8 .7 4)
CHI MNE Y TO P(1 4.12 )
F S
(3 7 .6 0 )
R IDG E
(1 3 .5 4 )
FS
(1 3.87 )
F F G
(13 .8 8)
FFG
(34 .2 5)
R IDG E
(3 6.71 )
C H IMNE Y T OP (14 .7 4)
FF (1 4 .7 3 )T W
(1 4 .5 0 )N G
(20 .0 4 )TF
(1 4.14 )N G
(2 0.05 )T F
(1 4 .0 7 )N G
(1 4 .6 6)TW
(1 4.23 )F S
(1 4.42 )
FS
(14 .3 6 )
F S
(1 4.75 )
F F
(1 4.02 )
FS
(1 3.97 )
F S
(1 3.92 )
F S
(1 3.96 )
FS
(14 .5 4 )
FS
(1 3 .8 8 )
NG
(1 3.09 )
FS
(1 3 .1 0 )
FS(13 .2 7 )
F S
(1 3 .2 2)
F S
(1 3 .1 7)
F S
(13 .7 4 )
F S
(1 3 .6 8 )
F S
(1 3.70 )
FS
(14 .0 9 )
NG
(1 4.16 )
FS
(14 .2 2 )
F S
(1 4.24 )
F S
(1 4.3 3 )
FS
(1 4.15 )
TS(1 4 .5 3 )
T S
(1 4 .5 5)
F S
(1 3.35 )
N G
(1 4 .6 7)
F S
(1 4 .7 1 )
FS
(1 3 .7 7)
NG
(1 3.7 8 )
F S
(1 3 .77 )
FS
(1 3.70 )
FS
(1 9.23 )T F
(1 3 .3 9 )N G
(1 4.04 )
NG
(1 4 .1 4 )
N G
(1 4.71 )
NG
(13 .3 9 )
FS
(1 2.94 )
F L
(1 3 .0 8 )
F L
(1 3.09 )
FL
(12 .8 3 )
FL
(1 2.87 )
FL
(13 .1 0)
F L
(13 .4 7)
F S
(1 4 .7 0 )
FS
(1 4 .6 1 )
F S(1 3.50 )
NG
(1 3.59 )
FS
(1 3 .5 2)
F S
(13 .5 7 )
F S
(1 4 .15 )
FS
(14 .1 1 )
FS
(1 4.13 )
FS
(1 4 .6 6)
TS
(1 3.97 )
N G
(1 4 .1 0)
FS
(1 4.69 )
FS
(1 3.26 )
F S
(1 3.7 3 )
F S
(1 3.58 )
N G
(13 .9 5)
N G
(1 3 .7 6)
NG
(1 3 .5 1)
NG
(1 4 .1 0)
N G
(1 3.03 )
F L
(12 .9 9)
F L
(1 3 .2 1 )
F S
(13 .1 2 )
NG
(1 9.85 )T F
(13.34)
NG(13.29)
FS
(1 3 .1 6)
W M
(14 .2 3)
N G
9 .7 2 '
10 .2 8'
9.77'
10.24'
P R OP ERTY
LI N E
P R OP ERTY
LI N E
PRO PE R TY
LINE
P R OP ERT Y
LI N E
4 0 "
T R E E
6 "
T R EE
8 "
T R EE12"
T R EE12"
T R E E
1 2 "
T R E E
1 2 "
T R EE
C U R B &
GUT TE R
EX IS T I NG
BUI LD ING
EXI S T ING
BU I LDI N G
EX IS T I NG
BUI LD ING
EXI STI N G
BU I L D I N G
TG
G MTG
S C O
GM CATVA C P AV EMEN T
M B
GA T E
GA T E
I C V
I C V
I C V
G A T E
8 "
TR E E
P A
P A
P A
P A
PA
PA
PA
P A
PA
D IRT
G A T E
PA
5 ' TA L L
WAL L
6' TA L L
WDF
6 ' T ALL
W DF
1' TA LL WA L L
W/ 5 ' TA L L W D F
ON T OP
F OUND LE AG &
T AG , I L L E GI BL E
FO U ND LE AG &
T AG , L S 43 8 4
F OUND LE AG &
T AG , L S4 1 36
D I R T
Δ=13°29'13"R=170.00'L=40.02'CLROOM TAGROOM NAME
?
1
10.00'SPOT ELEVATION
KEYNOTE TAG
REVISION TAG
PROPERTY LINE TAG90 00' 00"20.00'N E
FIREPIT -AS SELECTED TO BE LISTED AND APPROVED, VERIFY W/.
OWNER –PROVIDE POWER AND GAS AS REQUIRED –INSTALL AND
MAINTAIN CLEARANCES PER MFGR. AND SECTION 308 OF CFC
RECESSED MAIN SERVICE PANEL -400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE
OF PANEL TO ANY OBSTRUCTION) –GC TO COORDINATE W/. UTILITY COMPANY
A/C CONDENSER / HEAT PUMP -TO BE IN COMPLIANCE OF SECTION 307.3 OF CPC AS
SELECTED, VERIFY W/. OWNER -SIZE TBD, SEE T-24 ENERGY REPORT FOR MORE INFO –
PROVIDE POWER AND SOUND DAMPENING PAD AS REQ’D. –INSTALL AND MAINTAIN
REQUIRED CLEARANCES PER MFGR. INSTRUCTION
VERTICAL STORM DRAIN PIPE IN-WALL / OVERFLOW -MTL. PIPE PER
CHAPTER 11 OF CPC, SIZE PER TABLE 1103.1 (MIN. 2”DIA. PIPE & TYP. 3”DIA. PIPE) –
SEE CIVIL DWGS. FOR TERMINATION DTLS. ABV. OR BLW. GROUND. VERIFY ALL
TERMINATION POINTS, TYPE AND DETAILS W/. CIVIL PRIOR TO POURING THE CONCRETE
SLAB
OVERFLOW
DRAINLINE
UP
EXT. STAIRS -MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE ARTIFICIAL LIGHT
SOURCE AT THE TOP LANDING AND FOR STAIR TO THE BASEMENT AT BOTH TOP
AND BOTTOM LANDING (R303.8) -REF. DTL. 3/AD-1 -VERIFY TREADS DEPTH AND
RISERS HT. W/. CIVIL AND LANDSCAPE DWGS
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE
NEAREST 1/8" AND INTERIOR PARTITIONS ARE DIMENSIONED FROM FACE OF STRUCTURE TO FACE OF STRUCTURE (F.O.S.)
U.N.O. -CONTACT ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
GENERAL NOTE:
SEE SHEET A-3.0 FOR ROOF PLAN INFORMATION NOT SHOWN ON THIS SHEET (INCLUDING EAVE DETAILS AND PROJECTION
DISTANCES).
C.N.B. NOTES:
1. ISSUANCE OF A BUILDING PERMIT BY THE CITY OF NEWPORT BEACH DOES NOT RELIEVE APPLICANTS OF THE LEGAL
REQUIREMENTS TO OBSERVE COVENANTS, CONDITIONS AND RESTRICTIONS WHICH MAY BE RECORDED AGAINST THE PROPERTY
OR TO OBTAIN PLANS YOU SHOULD CONTACT YOUR COMMUNITY ASSOCIATIONS PRIOR TO COMMENCEMENT OF ANY
CONSTRUCTION AUTHORIZED BY THIS PERMIT.
2. PRIOR TO PERFORMING ANY WORK IN THE CITY RIGHT-OF-WAY AN ENCROACHMENT PERMIT MUST BE OBTAINED FROM THE
PUBLIC WORKS DEPARTMENT.
3. A CAL-OSHA PERMIT IS REQUIRED FOR EXCAVATIONS DEEPER THAN 5' AND FOR SHORING AND UNDERPINNING.
4. ELECTRICAL SERVICE TO BE UNDERGROUND FOR NEW CONSTRUCTION, REPLACEMENT BUILDING OR ADDITIONS TO AN
EXISTING BUILDING EXCEEDING 50% OF THE GROSS FLOOR AREA OF THE EXISTING BUILDING. (NBMC 12.32.015)
5. FIELD INSPECTOR TO REVIEW AND APPROVE UNDERGROUND ELEC. SERVICE REQUIREMENT PRIOR TO CONCRETE PLACEMENT.
6. EDISON COMPANY APPROVAL IS REQUIRED FOR METER LOCATION PRIOR TO INSTALLATION.
LANDSCAPE NOTES:
1. ENCROACHMENT PERMIT REQ'D. FOR ANY WORK PROPOSED IN THE PUBLIC R.O.W.
2. IF APPLICABLE, REF. PRELIMINARY LANDSCAPE PLANS, FOR ALL HARDSCAPE & PLANTING AREAS WITH RESPECTIVE HEIGHTS
AND MATERIALS.
POOL:
1. PROVIDE AN ALARM FOR DOORS AND WINDOWS WITH SILL HEIGHTS LESS THAN 60-INCHES ABV.F.F. OF THE DWELLING THAT
FORMS A PART OF THE POOL ENCLOSURE. THE ALARM SHALL BE LISTED AS A WATER HAZARD ENTRANCE ALARM IN
ACCORDANCE WITH UL 2017. THE DEACTIVATION SWITCH SHALL BE AT LEAST 60" ABOVE THE FLOOR IF THE RESIDENCE IS NOT
REQUIRED TO BE ACCESSIBLE. (CBC 3109 & ISPSC 305.4)
2. SUCTION OUTLETS SHALL BE DESIGNED AND INSTALLED WITH SUCTION ANTIENTRAPMENT GRATE IN ACCORDANCE WITH
ANSI/APSP-16 PER CBC 3109 SECTION (B) OF 115928. SUCTION ENTRAPMENT AVOIDANCE FOR POOL AND SPA SHALL BE
PROVIDED IN ACCORDANCE WITH APSP-7 PER ISPSC SECTION 310.
3. PROVIDE POWER SAFETY COVER IN COMPLIANCE WITH ASTM F1346-91 FOR POOL & SPA (CBC 3109 SECTION (3) OF 115922 &
ISPSC 305).
4. POOL ENCLOSURE FENCE SHALL BE 60-INCHES MIN. ABV. FS/NG MEASURED ON THE SIDE THAT FACES AWAY FROM
SWIMMING POOL W/. MAX VERTICAL CLEARANCE OF 2-INCHES BETWEEN FS/NG AND BOTTOM OF THE FENCE/BARRIER
MEASURED ON THE SIDE OF FENCE THAT FACES AWAY FROM SWIMMING POOL. OPENING, GAP, AND VOID IN ENCLOSURE FENCE
OR GATE SHALL NOT ALLOW THE PASSAGE OF 4-INCHES DIAMETER SPHERE OR LARGER. OUTSIDE SURFACE (FACING AWAY
FROM SWIMMING POOL) OF THE POOL ENCLOSURE INCLUDING THE GATE TO BE FREE OF PROTRUSIONS, CAVITIES, OR OTHER
PHYSICAL CHARACTERISTICS THAT WOULD SERVE AS HANDHOLDS OR FOOTHOLDS WHICH COULD ENABLE A CHILD FIVE YEARS
OLD OR YOUNGER TO CLIMB OVER. (CBC 3109 & ISPSC 305)
CASITA
BATH 1
3-CAR GARAGE
LAUNCH
FORMAL DINING
HALLWAY
STAIR
POWDER
PANTRY KITCHEN CASUAL DINING
FOYER
GREAT ROOM
SPA
DECK
COVERED
PORCH
1
1
2
2
3 3
W.I.C.
NEIGHBORING RESIDENCE
NOT A PART
NEIGHBORING RESIDENCE
NOT A PART
NEIGHBORING RESIDENCE
NOT A PART
WAVERLY DRIVE1
2
1 3
1
4
1
3
5
APN: 049-183-33
LOT 48
TRACT 1014
M.M. 33/31
PROJECT ZERO (FINISH FLOOR): 13.90'
T.O.S.: 13.78'
13.90' F.F.
13.90' F.F.ALLEYHOA SECOND LEVEL S.B.5' - 0"F.Y.S.B.
10' - 0"
TO STREET C.L.
20' - 0"S.Y.S.B.4' - 0"R.Y.S.B.
10' - 0"S.Y.S.B.4' - 0"TO B.O. CURB
9' - 2 5/8"
SLOPE PER CIVILSLOPE PER CIVIL CLR.29' - 10 3/4"CLR.
20' - 3"
CLR.
20' - 1 3/4"
N05o50'14"W 100.56
Δ=13o29'13" R=170.00' L=40.02'N19o17'3 2 "W 1 1 1 .95'N87o16'30"E 65.79'6
7
8
9
9
10
11 12913
13
14
13
15
15 9
16
13
9
17
918
18
12
19
20
21
22
23
9
(UNDER SEPARATE PERMIT)
22
222120 19
24
25
26
27
28
29
24
30
26
F.O.F.10' - 11"10' - 11 1/2"F.O.F.9' - 7 3/8"9' - 9 3/8"10' - 11 1/2"F.O.F.10' - 11"F.O.F.
7' - 10 5/8"
7' - 11 1/8"
8' - 11 7/8"
10' - 0 7/8"4' - 2 3/4"F.O.F.
15' - 6 7/8"
15' - 8 7/8"
F.O.F.
11' - 1 1/4"
11' - 3 1/4"24' - 9 3/4"F.O.F.24' - 7 3/4"F.O.F.42' - 2 3/4"42' - 4 3/4"29' - 4 3/4"23' - 10 1/4"5' - 4"4' - 1 5/8"5' - 8"4' - 7 1/8"10' - 11 1/2"4' - 11 3/4"5' - 0 3/4"5' - 11 1/2"F.O.F.
8' - 9 7/8"
F.O.F.
9' - 10 7/8"F.O.F.4' - 0 3/4"4' - 2 3/4"F.O.F.4' - 2 1/4"4' - 2 3/4"F.O.F.4' - 0 3/4"F.O.F.26' - 4 5/8"26' - 6 5/8"F.O.F.29' - 2 3/4"F.O.F.23' - 8 1/4"9
31
PT 1:
13.57' FS
PT 2:
13.29' FS
INTERPOLATED
PT 3:
13.70' FS
PT 4:
14.14' NG
GRADE PLANE DETERMINATION (CITY)
PT. 1 13.57'
PT. 2 13.29'
PT. 3 13.70'
PT. 4 14.14'
54.7' / 4 = 13.68'
AVERAGE SLOPE
(13.70' -13.29') / 92' -0 7/8" = .44%
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
SITE PLAN NOTESA
ANNOTATION LEGENDB
KEYNOTESC
BRANDON ARCHITECTS
01.28.22
ARCHITECTURAL
SITE PLANMITCHELL RESIDENCETOM & KELLY MITCHELL
141 GALAXY DR.
NEWPORT BEACH, CA 92660
CDP FIRST CHECK
2631 WAVERLY DR.
NEWPORT BEACH, CA 92663
A-0.0
TBD
BRIAN JOWETT
PROJECT NORTHTRUE NORTH
3/16" = 1'-0"1 ARCHITECTURAL SITE PLAN
NO. REVISION DATE
1 PROPERTY LINE
2 FRONT YARD SETBACK
3 SIDE YARD SETBACK
4 REAR YARD SETBACK
5 FOOTPRINT OF EXISTING STRUCTURE, TO BE REMOVED
6 RECESSED MAIN SERVICE PANEL, 400 AMP MAX. (MAINTAIN 36"" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION)
7 TRASH LOCATION - SCREEN FROM STREET AS NEEDED
8 EXTERIOR FIREPLACE - GAS ONLY APPLIANCE
9 PLANTED AREA - COORDINATE WITH LANDSCAPE DESIGNER
10 BUILT-IN BBQ ISLAND, MAX. HT. 60" - REF. LAND. DWGS.
11 OUTDOOR SHOWER - SHOWER PER LANDSCAPE DWGS.
12 (N.) WOOD DECK - REF. LAND. DWGS.
13 (N.) HARDSCAPE - STONE PAVERS (AS SELECTED), REF. LAND. DWGS.
14 PROVIDE POWER FOR POOL/SPA EQUIPMENT - G.C. TO VERIFY LOC'N., REF. LAND. DWGS.
15 (N.) HARDSCAPE - CONCRETE SIDE YARD, REF. LAND. DWGS.
16 (N.) DRIVEWAY PAVERS - REF. LAND. DWGS., SLOPE PER CIVIL
17 (E.) ROLLED-CURB - REPLACE AS REQ'D. PER C.N.B. STD. DETAIL
18 OPEN LAWN AREA - REF. LAND. DWGS.
19 (N.) PROPERTY LINE FENCE - METAL FENCE, PAINT TBD (MAX. 3' ABV. N.G.) REF. LANDS. DWGS.
20 (N.) PROPERTY LINE WALL - PLASTER FINISH TO MATCH (MAX. 6' ABV. N.G.)
21 (E.) PROPERTY LINE WALL - PROTECT IN PLACE
22 (N.) CMU LANDSCAPE WALL, REF. LANDSCAPE & CIVIL DWGS.
23 (N.) LANDSCAPE WALL, CMU PILASTER W/. STONE FINISH & PRE-CAST CONC. CAP, MAX. HT. 42", REF. CIVIL DWGS.
24 (E.) GRATE LOCATION - (REF. SURVEY & CIVIL DWGS.)
25 MAIL-BOX - VERIFY LOCATION W/. OWNER
26 (E.) IRRIGATION CONTROL VALVE - (REF. SURVEY & CIVIL DWGS.)
27 (E.) GAS METER LOCATION - (REF. SURVEY & CIVIL DWGS.)
28 (E.) CATV LOCATION - (REF. SURVEY & CIVIL DWGS.)
29 (E.) SEWER C.O. LOCATION - (REF. SURVEY & CIVIL DWGS.)
30 (E.) WATER METER LOCATION - (REF. SURVEY & CIVIL DWGS.)
31 (N.) CONCRETE STEPS ON GRADE - REF. CIVIL DWGS.
1/8" = 1'-0"2 GRADE PLANE EXHIBIT
PA2022-027
ROOM TAGROOM NAME
?
1
10.00'SPOT ELEVATION
KEYNOTE TAG
REVISION TAG
STRUCTURAL STEEL COLUMN -PER STRUCT., REF. STRUCT. DWGS. -PAINT AND SEAL
AS REQUIRED -ARCH. TO APPV. PAINT COLOR FOR EXPOSED STEEL COLUMNS
WALL FRAMING -REF. A-2.0 DIMENSION PLANS FOR SIZING AND DIMENSIONS
CONCRETE WALL -12" REINFORCED CAST IN PLACE CONCRETE WALL TYP. U.N.O. PER
STRUCT., REF. STRUCT. DWGS. -FOR BASEMENT/RETAINING CONCRETE WALL PROVIDE
WATERPROOFING OR DAMPROOFING AND DRAINAGE AS REQUIRED PER SECTION R406.1 &
R406.2. REF/ SOILS REPORT, WATERPROOFING & DAMPROOFING NOTES ON SHEET T-1.1 -
EXPOSED SURFACES TO HAVE TROWELED SMOOTH FINISH WITH A LIGHT GRAY COLOR,
PROVIDE SAMPLE FOR ARCH. APPROVAL
STRUCTURAL WOOD POST/COLUMN -PER STRUCT., REF. STRUCT. DWGS. -PAINT, STAIN
AND SEAL AS REQUIRED -ARCH. TO APPV. PAINT COLOR FOR EXPOSED WOOD
POST/COLUMN, IF TO BE STAINED PROVIDE STAINED SAMPLE FOR ARCH. APPROVAL
SLAB/FRAMING DEPRESSION -SEE STRUCT. DWGS. FOR THE RECESSION DETAILS -FOR
RECESSION SPECIFIC TO EQUIPMENT OR ASSEMBLY VERIFY THE REQUIRED RECESSION
W/. MFGR. OR FABRICATOR -SHOWER RECESSION TO BE VERIFIED W/. I.D.
VERTICAL STORM DRAIN PIPE IN-WALL / OVERFLOW -MTL. PIPE PER
CHAPTER 11 OF CPC, SIZE PER TABLE 1103.1 (MIN. 2”DIA. PIPE & TYP. 3”DIA. PIPE) –
SEE CIVIL DWGS. FOR TERMINATION DTLS. ABV. OR BLW. GROUND. VERIFY ALL
TERMINATION POINTS, TYPE AND DETAILS W/. CIVIL PRIOR TO POURING THE CONCRETE
SLAB
OVERFLOW
DRAINLINE
NOTE:
GENERAL CONTRACTOR TO PROVIDE SHOP DRAWINGS CONSISTENT WITH THE CONSTRUCTION DOCUMENTS. GENERAL
CONTRACTOR TO REVIEW AND APPROVE ALL FINAL SHOP DRAWINGS PRIOR TO FABRICATION & POURING.
ARCHITECT & STRUCTURAL ENGINEER TO REVIEW SHOP DWGS. FOR DESIGN CONFORMITY TO THE CONSTRUCTION DOCUMENTS
PRIOR TO FABRICATION & POURING.
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE
NEAREST 1/8" -CONTACT ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
WATERPROOFING AND DAMPPROOFING NOTES:
R406.1 CONCRETE AND MASONRY FOUNDATION DAMPPROOFING
EXCEPT WHERE REQUIRED BY SECTION R406.2 TO BE WATERPROOFED, FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE
INTERIOR SPACES AND FLOORS BELOW GRADE SHALL BE DAMPPROOFED FROM THE HIGHER OF (A) THE TOP OF THE FOOTING OR
(B) 6 INCHES (152 MM) BELOW THE TOP OF THE BASEMENT FLOOR, TO THE FINISHED GRADE. MASONRY WALLS SHALL HAVE NOT
LESS THAN 3/8-INCH (9.5 MM) PORTLAND CEMENT PARGING APPLIED TO THE EXTERIOR OF THE WALL. THE PARGING SHALL BE
DAMPPROOFED IN ACCORDANCE WITH ONE OF THE FOLLOWING:
1. BITUMINOUS COATING.
2. THREE POUNDS PER SQUARE YARD (1.63 KG/M2) OF ACRYLIC MODIFIED CEMENT.
3. ONE-EIGHTH-INCH (3.2 MM) COAT OF SURFACE-BONDING CEMENT COMPLYING WITH ASTM C887.
4. ANY MATERIAL PERMITTED FOR WATERPROOFING IN SECTION R406.2.
5. OTHER APPROVED METHODS OR MATERIALS.
EXCEPTION:PARGING OF UNIT MASONRY WALLS IS NOT REQUIRED WHERE A MATERIAL IS APPROVED FOR DIRECT APPLICATION
TO THE MASONRY.CONCRETE WALLS SHALL BE DAMPPROOFED BY APPLYING ANY ONE OF THE LISTED DAMPPROOFING
MATERIALS OR ANY ONE OF THE WATERPROOFING MATERIALS LISTED IN SECTION R406.2 TO THE EXTERIOR OF THE WALL.
R406.2 CONCRETE AND MASONRY FOUNDATION WATERPROOFING
IN AREAS WHERE A HIGH WATER TABLE OR OTHER SEVERE SOIL-WATER CONDITIONS ARE KNOWN TO EXIST, EXTERIOR
FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE INTERIOR SPACES AND FLOORS BELOW GRADE SHALL BE
WATERPROOFED FROM THE HIGHER OF (A) THE TOP OF THE FOOTING OR (B) 6 INCHES (152 MM) BELOW THE TOP OF THE
BASEMENT FLOOR, TO THE FINISHED GRADE. WALLS SHALL BE WATERPROOFED IN ACCORDANCE WITH ONE OF THE FOLLOWING:
1. TWO-PLY HOT-MOPPED FELTS.
2. FIFTY-FIVE-POUND (25 KG) ROLL ROOFING.
3. SIX-MIL (0.15 MM) POLYVINYL CHLORIDE.
4. SIX-MIL (0.15 MM) POLYETHYLENE.
5. FORTY-MIL (1 MM) POLYMER-MODIFIED ASPHALT.
6. SIXTY-MIL (1.5 MM) FLEXIBLE POLYMER CEMENT.
7. ONE-EIGHTH-INCH (3 MM) CEMENT-BASED, FIBER-REINFORCED, WATERPROOF COATING.
8. SIXTY-MIL (1.5 MM) SOLVENT-FREE LIQUID-APPLIED SYNTHETIC RUBBER.
ALL JOINTS IN MEMBRANE WATERPROOFING SHALL BE LAPPED AND SEALED WITH AN ADHESIVE COMPATIBLE WITH THE
MEMBRANE.
EXCEPTION: ORGANIC-SOLVENT-BASED PRODUCTS SUCH AS HYDROCARBONS, CHLORINATED HYDROCARBONS, KETONES AND
ESTERS SHALL NOT BE USED FOR ICF WALLS WITH EXPANDED POLYSTYRENE FORM MATERIAL. USE OF PLASTIC ROOFING
CEMENTS, ACRYLIC COATINGS, LATEX COATINGS, MORTARS AND PARGINGS TO SEAL ICF WALLS IS PERMITTED. COLD-SETTING
ASPHALT OR HOT ASPHALT SHALL CONFORM TO TYPE C OF ASTM D449. HOT ASPHALT SHALL BE APPLIED AT A TEMPERATURE OF
LESS THAN 200°F (93°C).
SLAB ON GRADE NOTE:
PROVIDE BASE PER R506.2.2 AND VAPOR RETARDER PER R506.2.3 W/. CAPILLARY BREAK
1
1
2
2
3 3
20' - 10 1/4"53' - 10 3/4"18' - 6 3/8"16' - 6"1' - 7 3/8"1' - 2 1/4"
5' - 6 3/4"5' - 8"5' - 3 3/4"
5' - 9 1/4"17' - 5 1/8"19' - 3 3/8"7' - 10"6' - 8"7' - 10"4 5/8"2' - 8"4 5/8"3' - 0 1/8"4 5/8"5' - 10 3/4"4 5/8"
4 5/8"4' - 10 3/4"4 5/8"1' - 2"13' - 4 3/8"6' - 2 1/8"10' - 10 3/4"20' - 0 3/4"21' - 0 1/8"9' - 11 3/8"6"3' - 5 3/8"1' - 2"12' - 10 3/4"5' - 6 1/2"13' - 0"1' - 4 1/2"1' - 7 3/8"2' - 1 3/4"12' - 0"1' - 9 7/8"CURB
6"CURB6"1' - 4 3/4"8' - 0"1' - 6"CURB
6"6' - 4 5/8"1' - 5 7/8"17' - 0"1' - 7"CURB6"16' - 1 1/8"3' - 0"1' - 9 1/4"
CASITA
BATH 1 W.I.C.
LAUNCH
FORMAL DINING
HALLWAY
STAIR
POWDER
PANTRY
KITCHEN
CASUAL DINING
FOYER
GREAT ROOM
3-CAR GARAGE
SLOPE PER CIVIL
13.90' F.F.
13.90' F.F.
3" SLAB DEPRESSION FOR SHOWER -
VERIFY W/. G.C. & REF. STRUCT. DWGS.
SLAB DEPRESSION FOR FIREPLACE -
VERIFY W/. G.C. & MFGR. & REF.
STRUCT. DWGS.
SLAB DEPRESSION FOR DOOR SYSTEM -VERIFY
W/. G.C. & MFGR. & REF. STRUCT. DWGS
SLAB DEPRESSION FOR FIREPLACE -
VERIFY W/. G.C. & MFGR. & REF.
STRUCT. DWGS.
6' - 11 1/8"10' - 6"
SLAB DEPRESSION FOR DOOR
SYSTEM -VERIFY W/. G.C. &
MFGR. & REF. STRUCT. DWGS
9 3/4"9 3/4"
SLAB DEPRESSION FOR DOOR
SYSTEM -VERIFY W/. G.C. &
MFGR. & REF. STRUCT. DWGS
1
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
ANNOTATION LEGENDB
SLAB EDGE NOTESA
KEYNOTE LEGENDC
01.28.22
SLAB EDGE PLANMITCHELL RESIDENCETOM & KELLY MITCHELL
141 GALAXY DR.
NEWPORT BEACH, CA 92660
CDP FIRST CHECK
2631 WAVERLY DR.
NEWPORT BEACH, CA 92663
A-0.1
TBD
BRIAN JOWETT
NO. REVISION DATE
1 RECESSED MAIN SERVICE PANEL, 400 AMP MAX. (MAINTAIN 36"" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION)
1/4" = 1'-0"1 SLAB EDGE PLAN
PA2022-027
UP
DNUP
395 SF
1
368 SF
10
251 SF
HOA 1
221 SF
6
106 SF
COVERED ENTRY
136 SF
FRONT PATIO216 SF
3
103 SF
4
40 SF
5
198 SF
9
352 SF
8
624 SF
11
7 SF
7
12 SF
12
73 SF
13
25 SF
2
19' - 8"1' - 2 1/4"16' - 8 7/8"19' - 3 3/8"17' - 10 1/2"1' - 8 7/8"16' - 4 1/2"5' - 9 1/4"17' - 5 1/8"19' - 3 3/8"22' - 4 1/8"
6' - 8"
16' - 6 1/2"
5' - 8"1' - 2"13' - 4 3/8"6' - 7 5/8"10' - 5 1/4"20' - 0 3/4"15' - 5 3/4"7' - 1 1/4"11' - 0 5/8"21' - 0 1/8"13' - 0"19' - 0 3/4"34' - 10 7/8"741 SF
19
106 SF
MASTER BALCONY
332 SF
20
9 SF
21
233 SF
16
19 SF
14
517 SF
17
156 SF
1827 SF
15
1' - 6"18' - 3 1/4"11' - 10"25' - 5 3/4"17' - 7"
5' - 8"1' - 6 1/2"19' - 1 1/4"1' - 5 7/8"19' - 7 3/8"11' - 11 1/8"25' - 5 3/4"17' - 5"17' - 2 1/8"8' - 7"30' - 1 3/4"12' - 7"7' - 4 1/2"17' - 8 3/4"29' - 1 3/4"275 SF
22
45 SF
23
300 SF
24
211 SF
25
114 SF
26
224 SF
27
66 SF
28
96 SF
29
387 SF
30
104 SF
31
314 SF
32
103 SF
33
650 SF
34
73 SF
35
17' - 5 1/2"12' - 10 1/4"5' - 0 1/2"12' - 11 5/8"19' - 11"22' - 6 1/2"
16' - 3"6' - 3 5/8"5' - 0 1/2"15' - 2 1/2"7' - 2 1/2"10' - 5 3/4"15' - 0 1/4"6' - 3 5/8"11' - 9"21' - 0 3/4"3' - 1 1/2"18' - 5 1/2"
21' - 0 3/4"3' - 1 1/2"18' - 5 1/2"4' - 5 5/8"16' - 3 5/8"35' - 2 7/8"14' - 10 3/4"13' - 0 3/4"4' - 11 1/4"32' - 10 3/4"115 SF
A
62 SF
B
36 SF
C
451 SF
D
258 SF
E
72 SF
F
6 SF
L-A
1 SF
L-B 1 SF
L-C
11 SF
L-D
16 SF
L-E
154 SF
L-F
101 SF
L-G
67 SF
L-H
165 SF
H-A
101 SF
L-J
59 SF
L-K
2 SF
L-I
40 SF
L-L
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
01.28.22
AREA PLANSMITCHELL RESIDENCETOM & KELLY MITCHELL
141 GALAXY DR.
NEWPORT BEACH, CA 92660
CDP FIRST CHECK
2631 WAVERLY DR.
NEWPORT BEACH, CA 92663
A-0.2
TBD
BRIAN JOWETT
NO. REVISION DATE
1/8" = 1'-0"1 FIRST FLOOR AREA
1/8" = 1'-0"2 SECOND FLOOR AREA
1/8" = 1'-0"3 ROOF AREA
FIRST FLOOR AREA (HOA)
LIVING
4 103 SF
5 40 SF
6 221 SF
7 7 SF
8 352 SF
9 198 SF
10 368 SF
11 624 SF
12 12 SF
13 73 SF
HOA 1 251 SF
2247 SF
GARAGE
1 395 SF
2 25 SF
3 216 SF
636 SF
GRAND TOTAL 2883 SF
TOTAL
TOTAL
FIRST FLOOR AREA (CITY)
LIVING
4 103 SF
5 40 SF
6 221 SF
7 7 SF
8 352 SF
9 198 SF
10 368 SF
11 624 SF
12 12 SF
13 73 SF
1997 SF
GARAGE
1 395 SF
2 25 SF
3 216 SF
636 SF
GRAND TOTAL 2633 SF
TOTAL
TOTAL
SECOND FLOOR AREA
LIVING
14 19 SF
15 27 SF
16 233 SF
17 517 SF
18 156 SF
19 741 SF
20 332 SF
21 9 SF
GRAND TOTAL 2032 SF
1/8" = 1'-0"4 FIRST FLOOR OPEN AREA
OPEN AREA
A 115 SF
B 62 SF
C 36 SF
D 451 SF
E 258 SF
F 72 SF
GRAND TOTAL 992 SF
1/8" = 1'-0"5 LANDSCAPE AREA
LANDSCAPE AREA
L-A 6 SF
L-B 1 SF
L-C 1 SF
L-D 11 SF
L-E 16 SF
L-F 154 SF
L-G 101 SF
L-H 67 SF
L-I 2 SF
L-J 101 SF
L-K 59 SF
L-L 40 SF
GRAND TOTAL 558 SF
FRONT YARD AREA
HARDSCAPE AREA 165 SF
LANDSCAPE AREA 168 SF
GRAND TOTAL 334 SF
334 / 2 = 167 S.F. < 168 S.F.
ROOF AREA
SLOPED ROOF
24 300 SF
25 211 SF
26 114 SF
27 224 SF
28 66 SF
29 96 SF
30 387 SF
31 104 SF
32 314 SF
33 103 SF
34 650 SF
35 73 SF
2642 SF
FLAT ROOF
22 275 SF
23 45 SF
320 SF
GRAND TOTAL 2962 SF
TOTAL SLOPED
TOTAL FLAT
PA2022-027
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
01.28.22
3D VIEWSMITCHELL RESIDENCETOM & KELLY MITCHELL
141 GALAXY DR.
NEWPORT BEACH, CA 92660
CDP FIRST CHECK
2631 WAVERLY DR.
NEWPORT BEACH, CA 92663
A-1.0
TBD
BRIAN JOWETT
NO. REVISION DATE
1 AXONOMETRIC - NE 2 AXONOMETRIC - NW
3 AXONOMETRIC - SE 4 AXONOMETRIC - SW
PA2022-027
UP
A-4.1
A-4.0
A-4.02
A-4.1
2
1
1
1
A-5.0
1
A-5.0
GREAT ROOM
FOYER
CASUAL DINING
KITCHEN
FORMAL DINING
LAUNCH
HALLWAY
POWDER
PANTRY
3-CAR GARAGE
CASITA
BATH 1
STAIR
W.I.C.
15
14
17
6
7
11
10
78
16
1514
17
12
16
20
12 6
13
9
19
4
8
10
9
11
1
1
S.Y.S.B.4' - 0"R.Y.S.B.
10' - 0"S.Y.S.B.4' - 0"CLR.29' - 10 3/4"CLR.
20' - 3"
CLR.
20' - 1 3/4"TYP.11"CLR.
4' - 3 5/8"
CLR.
4' - 2 5/8"CLR.4' - 0"R @ 0' -6 1/8"22
13.90' F.F.
HOA SECOND LEVEL S .B.5' - 0"
HOA
10' - 0"
12
1 3
1
4
1 3
5
6
7
8
9
10
11
12
13
13
13.90' F.F.4' - 2 3/4"14
2
A-5.0
2
A-5.0
5
4
5 4
2
3
2
3
15
16
17
17
18
5
SLOPE PER CIVIL
ROOM TAGROOM NAME
1
A-5.0
1 1
?
1
1
A-4.0
1
1 1
1
ELEVATION / SECTION INDICATOR
AD-1.0
1 CALL-OUT TAG
10.00'SPOT ELEVATION
KEYNOTE TAG
REVISION TAG
DOOR / WINDOW / WINDOW WALL TAG
FIRE RATED CEILING ASS'Y -REF. DTLS. 7/AD-1.0
1-HR RATED INT CONDITION -REF. DTLS. 7/AD-1.0
1-HR RATED EXT CONDITION -REF. DTLS. 7/AD-1.0
STRUCTURAL STEEL COLUMN PER STRUCT., REF. STRUTC.
DWGS, -PAINT AND SEAL AS REQUIRED –ARCH. TO APPV.
COLOR FOR EXPOSED STEEL COLUMNS
STRUCTURAL WOOD POST/COLUMN COLUMN -PER STRUCT., REF. STRUTC. DWGS, -
PAINT, STAIN AND SEAL AS REQUIRED –ARCH. TO APPV. PAINT COLOR FOR EXPOSED
WOOD POST/COLUMN, IF TO BE STAINED PROVIDE STAINED SAMPLE FOR ARCH,
APPROVAL
DOORS -AS SPECIFIED, SEE WINDOW SCHEDULE AND GENERAL NOTES ON SHEET A-7.0 -
SHGC & U-FCTOR PER T-24 ENERGY REPORT – SEE SHEET AD-2.0 FOR JAMB, HEAD AND
THRESHOLD DETAILS, PROVIDE FLASHING AND WATERPROOFING AT DOOR OPENING PER
THE DOOR MFGR. INSTRUCTION AND/OR FLASHING MFGR. INSTRUCTION PER SECTIONS
R609.1 & R703.4 OF CRC
WINDOW -AS SPECIFIED, SEE WINDOW SCHEDULE AND GENERAL NOTES ON
SHEET A-7.0 -SHGC & U-FCTOR PER T-24 ENERGY REPORT – SEE SHEET
AD-2.0 FOR JAMB, HEAD AND SILL DETAILS, PROVIDE FLASHING AND
WATERPROOFING AT WINDOW OPENING PER THE WINDOW MFGR.
INSTRUCTION AND/OR FLASHING MFGR. INSTRUCTION PER SECTIONS R609.1
& R703.4 OF CRC
KITCHEN RANGE W/. EXHAUST HOOD -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
PROVIDE POWER AND GAS AS REQUIRED -30”MIN. VERTICAL CLEARANCE TO ANY
COMBUSTIBLE MATERIAL ABV. COOKING TOP (CMC 920.3.2) –EXHAUST HOOD TO HAVE
EXHAUST RATE OF MIN. 100 CFM AND VENT TO OUTDOOR , HOOD DUCTS TO BE OF
METAL WITH SMOOTH INTERIOR FINISH PER SECTION 504.3 OF CMC
KITCHEN/BAR SINK -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –SINK TO COMPLY
W/. REQUIREMENT OF SECTION 420.0 OF CPC AND HAVE A MAX FLOW RATE OF 1.8 GPM
@ 60 PSI PER SECTION 4.303.1 OF CALGREEN –TRAP AND VENT FOR ISLAND SINK AND
SIMILAR EQUIPMENT SHALL BE PER SECTION 909.0 OF CPC
VANITY SINK -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
LAVATORY TO HAVE 24”MIN. CLEAR SPACE IN FRONT OF IT.(CPC 402.5)
W/. MAXIMUM FLOW RATE OF 1.2 GPM @ 60 PSI AND MIN. FLOW RATE OF
0.8 GPM @ 20 PSI PER SECTION 4.303.1 OF CALGREEN
WASHER (W) / DRYER (D) / STACKED (W/D)-AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER –PROVIDE POWER , GAS, WATER SUPPLY & DRAINAGE AS REQUIRED -THE
CLOTHES DRYERS VENT SHALL BE OF A RIGID METALLIC MATERIAL AND HAVE A
BACKDRAFT DAMPER (CMC 504.4) AND SHALL NOT EXCEED 14-FEET IN OVERALL LENGTH
WITH MAX. OF TWO (2) 90-DEGREE ELBOW, SUBTRACT 2-FEET FOR EACH ADDITIONAL 90-
DEGREE ELBOW. SEE WASHER & DRYER NOTES, REF. T-1.1.
REFRIGERATOR (REF) / FREEZER (FRZ) -AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER –PROVIDE POWER AND WATER SUPPLY AS REQUIRED
BUILT-IN APPLIANCE / DISHWASHER (DW) / TRASH COMPACTOR (TR)-AS SELECTED PER
I.D., VERIFY W/. I.D. & OWNER –PROVIDE POWER , WATER SUPPLY & DRAINAGE PIPE AS
REQUIRED
TOILET -WATER CLOSET SHALL BE IN COMPLIANCE OF SECTION 411.0 OF CPC AND HAS
MAX EFFECTIVE FLUSH RATE OF 1.28 GAL. PER FLUSH (CPC 411.2). WATER CLOSETS
CLR. TO BE 24”IN FRONT AND 15”FROM ITS CENTER TO ANY SIDE WALL OR
OBSTRUCTION. (CPC 402.5 & CRC R307) –REF. CALGREEN NOTES ON T SHTS. FOR MAX
FLOW RATE
CASEWORK, TALL CABINET -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER
CASEWORK, BASE CABINET W/. COUNTERTOP -AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER
CASEWORK, UPPER CABINET/SHELVES -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER
BUILT-IN CLOSET -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER
FIREPLACE -FACTORY-BUILT DIRECT VENT GAS FIREPLACE W/. SEALED COMBUSTION
(CALGREEN 4.503) -FACTORY-BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR
COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING
AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. (CRC R1004.1)
ELEVATOR -PRIVATE RESIDENCE ELEVATOR IN COMPLIANCE W/. ASME A17.1/CSA B44
AS SELECTED PER PLANS, VERIFY W/. OWNER –PROVIDE POWER AS REQ'D. (CRC 321.1)
A/C CONDENSER / HEAT PUMP -TO BE IN COMPLIANCE OF SECTION 307.3 OF CPC AS
SELECTED, VERIFY W/. OWNER -SIZE TBD, SEE T-24 ENERGY REPORT FOR MORE INFO –
PROVIDE POWER AND SOUND DAMPENING PAD AS REQ’D. –INSTALL AND MAINTAIN
REQUIRED CLEARANCES PER MFGR. INSTRUCTION
FAU -PROVIDE GAS S.O., POWER, AND VENTING AS REQ'D. BY MFG'R. –INSTALL PER
MFGR. INSTRUCTION
ROOF/DECK DRAIN -PER CHAPTER 11 OF CPC -SIZE THE DRAIN AND PIPING PER TABLE
1103.1 AND 1103.2 OF CPC –ROOF DRAIN SHALL HAVE DOMED STRAINER (CPC 1102.2) –
REF. DETAIL 11/AD-1.0
OVERFLOW OR EMERGENCY DRAIN -PER CHAPTER 11 OF CPC -COPPER OR EQ., INSTALL
PER MFGR. INSTRUC., SLOPED TOWARD IN-WALL DRAIN INLETS –SLOPE AND SIZE PER
TABLE 1103.3 OF CPC –REF. DTL. 11/AD-1.0
UP
20R@7 1/2"
STAIRS -MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL OF NOT
LESS THAN 1 FOOT CANDLE AS MEASURED AT THE CENTER OF TREADS AND
LANDING WITH ARTIFICIAL LIGHTING (R303.7) -REF. DTL. 3/AD-1
ELEVATOR -PRIVATE RESIDENCE ELEVATOR IN COMPLIANCE W/. ASME A17.1/CSA B44
AS SELECTED PER PLANS, VERIFY W/. OWNER –PROVIDE POWER AS REQUIRED (CRC
R321.1)
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
KEYNOTESB
ANNOTATION LEGENDA
BRANDON ARCHITECTS
01.28.22
FIRST LEVEL FLOOR
PLANMITCHELL RESIDENCETOM & KELLY MITCHELL
141 GALAXY DR.
NEWPORT BEACH, CA 92660
CDP FIRST CHECK
2631 WAVERLY DR.
NEWPORT BEACH, CA 92663
A-2.0
TBD
BRIAN JOWETT
1/4" = 1'-0"1 FIRST LEVEL FLOOR PLAN
1 PROPERTY LINE
2 FRONT YARD SETBACK
3 SIDE YARD SETBACK
4 REAR YARD SETBACK
5 FIREPLACE - PREFABRICATED, GAS ONLY, 'DAVINCI - ISLAND' - ANSI Z21.50B-2014 [DTL. 22/AD-1] (FACTORY BUILT
FIREPLACES, CHIMNEYS, AND ALL OF THEIR COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE W/. THEIR
LISTING AND MFG'R. INSTALLATION INSTRUCTIONS. GASEOUS FUEL BURNING PAN MUST BE PERMANENTLY ANCHORED TO
THE FIREBOX. FIREPLACE MUST COMPLY W/. THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES.)
6 CUSTOM SHOWER SEAT PER I.D.
7 KITCHEN ISLAND - BASE CABINET, COUNTER, AND APPLIANCES PER I.D - VERIFY SIZE W/. I.D. & OWNER
8 KITCHEN SINK - AS SELECTED
9 RANGE - VERIFY APPLIANCE W/. OWNER - PROVIDE HOOD CAPABLE OF 100 CFM MIN. (VERIFY W/. MFG.) - VENT TO OUTDOOR
AIR
10 RECESSED MAIN SERVICE PANEL, 400 AMP MAX. (MAINTAIN 36"" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION)
11 INTERIOR STAIR MOUNTED HANDRAIL - 34"-38" ABV. NOSING, REF. DTL. 4/AD-1
12 STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT
CANDLE (CBC 1205.4) REF. DTL. 3/AD-1
13 ENCLOSED USEABLE SPACE UNDER STAIRWAY USE 5/8"" TYPE 'X' GYP. BD. FINISH TYP. (1/2"" MIN.) (CRC R302.7)
14 SHOWER - PROVIDE TILE W/. CEMENT BACKING MIN. 72" HIGH (R307.2)
15 TRASH LOCATION - SCREEN FROM STREET AS NEEDED
16 GARAGE DOOR - RATED, 1-3/8"" SOLID CORE, SELF-CLOSING AND SELF-LATCHING. REF. DOOR SCHEDULE
17 GARAGE DOOR - CUSTOM BUILT, REF. SCHED.- ARCH TO APPV. SHOP DWGS. PRIOR TO FAB.
18 EXIT DOORWAY NOT LESS THAN 3FT. WIDE AND 6 FT. 6 INCHES IN HEIGHT, AND W/. MIN. CLEAR WIDTH OF 32 INCHES. R311
NO. REVISION DATE
PA2022-027
DNUP
A-4.1
A-4.0
A-4.02
A-4.1
2
1
1
1
A-5.0
1
A-5.0
MASTER BATHROOM
MASTER BEDROOM
MASTER CLOSET
LAUNDRY
DEN
BEDROOM 2
BATH 2
HALL
W.I.C.
BUNK ROOM
BATH 3
W.C.
22
30
33
21 23
18
2425
35
33
29
28
22
27
32
27
26 23
20
2524
29
2628
21
19
34
32
31
30
31
36
36 35
34
S.Y.S.B.4' - 0"R.Y.S.B.
10' - 0"S.Y.S.B.4' - 0"HOA SECOND LEVEL S.B.5' - 0"
F.Y.S.B.
1 0' - 0"
7:12 7:12
7:12
7:12
7:12
7:12TYP.11"TYP.4' - 11"TYP.4' - 0"TYP.
4' - 3 5/8"
TYP.
4' - 3 5/8"
R @ 0' -6 3/32"18 R @0' -6 1/8"22
25.11' F.F.
12
13
1 4
1 3
5
65
7
8
9
8
10
11
2% SLOPE MIN.
12
13
14
15
15
16
2
A-5.0
2
A-5.0
3' - 10 3/4"17
17
17 5
18
1920
19
20
19
19
3:12
21
6
6
ROOM TAGROOM NAME
1
A-5.0
1 1
?
1
1
A-4.0
1
1 1
1
ELEVATION / SECTION INDICATOR
AD-1.0
1 CALL-OUT TAG
10.00'SPOT ELEVATION
KEYNOTE TAG
REVISION TAG
DOOR / WINDOW / WINDOW WALL TAG
FIRE RATED CEILING ASS'Y -REF. DTLS. 7/AD-1.0
1-HR RATED INT CONDITION -REF. DTLS. 7/AD-1.0
1-HR RATED EXT CONDITION -REF. DTLS. 7/AD-1.0
STRUCTURAL STEEL COLUMN PER STRUCT., REF. STRUTC.
DWGS, -PAINT AND SEAL AS REQUIRED –ARCH. TO APPV.
COLOR FOR EXPOSED STEEL COLUMNS
STRUCTURAL WOOD POST/COLUMN COLUMN -PER STRUCT., REF. STRUTC. DWGS, -
PAINT, STAIN AND SEAL AS REQUIRED –ARCH. TO APPV. PAINT COLOR FOR EXPOSED
WOOD POST/COLUMN, IF TO BE STAINED PROVIDE STAINED SAMPLE FOR ARCH,
APPROVAL
DOORS -AS SPECIFIED, SEE WINDOW SCHEDULE AND GENERAL NOTES ON SHEET A-7.0 -
SHGC & U-FCTOR PER T-24 ENERGY REPORT – SEE SHEET AD-2.0 FOR JAMB, HEAD AND
THRESHOLD DETAILS, PROVIDE FLASHING AND WATERPROOFING AT DOOR OPENING PER
THE DOOR MFGR. INSTRUCTION AND/OR FLASHING MFGR. INSTRUCTION PER SECTIONS
R609.1 & R703.4 OF CRC
WINDOW -AS SPECIFIED, SEE WINDOW SCHEDULE AND GENERAL NOTES ON
SHEET A-7.0 -SHGC & U-FCTOR PER T-24 ENERGY REPORT – SEE SHEET
AD-2.0 FOR JAMB, HEAD AND SILL DETAILS, PROVIDE FLASHING AND
WATERPROOFING AT WINDOW OPENING PER THE WINDOW MFGR.
INSTRUCTION AND/OR FLASHING MFGR. INSTRUCTION PER SECTIONS R609.1
& R703.4 OF CRC
KITCHEN RANGE W/. EXHAUST HOOD -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
PROVIDE POWER AND GAS AS REQUIRED -30”MIN. VERTICAL CLEARANCE TO ANY
COMBUSTIBLE MATERIAL ABV. COOKING TOP (CMC 920.3.2) –EXHAUST HOOD TO HAVE
EXHAUST RATE OF MIN. 100 CFM AND VENT TO OUTDOOR , HOOD DUCTS TO BE OF
METAL WITH SMOOTH INTERIOR FINISH PER SECTION 504.3 OF CMC
KITCHEN/BAR SINK -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –SINK TO COMPLY
W/. REQUIREMENT OF SECTION 420.0 OF CPC AND HAVE A MAX FLOW RATE OF 1.8 GPM
@ 60 PSI PER SECTION 4.303.1 OF CALGREEN –TRAP AND VENT FOR ISLAND SINK AND
SIMILAR EQUIPMENT SHALL BE PER SECTION 909.0 OF CPC
VANITY SINK -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
LAVATORY TO HAVE 24”MIN. CLEAR SPACE IN FRONT OF IT.(CPC 402.5)
W/. MAXIMUM FLOW RATE OF 1.2 GPM @ 60 PSI AND MIN. FLOW RATE OF
0.8 GPM @ 20 PSI PER SECTION 4.303.1 OF CALGREEN
WASHER (W) / DRYER (D) / STACKED (W/D)-AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER –PROVIDE POWER , GAS, WATER SUPPLY & DRAINAGE AS REQUIRED -THE
CLOTHES DRYERS VENT SHALL BE OF A RIGID METALLIC MATERIAL AND HAVE A
BACKDRAFT DAMPER (CMC 504.4) AND SHALL NOT EXCEED 14-FEET IN OVERALL LENGTH
WITH MAX. OF TWO (2) 90-DEGREE ELBOW, SUBTRACT 2-FEET FOR EACH ADDITIONAL 90-
DEGREE ELBOW. SEE WASHER & DRYER NOTES, REF. T-1.1.
REFRIGERATOR (REF) / FREEZER (FRZ) -AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER –PROVIDE POWER AND WATER SUPPLY AS REQUIRED
BUILT-IN APPLIANCE / DISHWASHER (DW) / TRASH COMPACTOR (TR)-AS SELECTED PER
I.D., VERIFY W/. I.D. & OWNER –PROVIDE POWER , WATER SUPPLY & DRAINAGE PIPE AS
REQUIRED
TOILET -WATER CLOSET SHALL BE IN COMPLIANCE OF SECTION 411.0 OF CPC AND HAS
MAX EFFECTIVE FLUSH RATE OF 1.28 GAL. PER FLUSH (CPC 411.2). WATER CLOSETS
CLR. TO BE 24”IN FRONT AND 15”FROM ITS CENTER TO ANY SIDE WALL OR
OBSTRUCTION. (CPC 402.5 & CRC R307) –REF. CALGREEN NOTES ON T SHTS. FOR MAX
FLOW RATE
CASEWORK, TALL CABINET -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER
CASEWORK, BASE CABINET W/. COUNTERTOP -AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER
CASEWORK, UPPER CABINET/SHELVES -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER
BUILT-IN CLOSET -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER
FIREPLACE -FACTORY-BUILT DIRECT VENT GAS FIREPLACE W/. SEALED COMBUSTION
(CALGREEN 4.503) -FACTORY-BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR
COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING
AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. (CRC R1004.1)
ELEVATOR -PRIVATE RESIDENCE ELEVATOR IN COMPLIANCE W/. ASME A17.1/CSA B44
AS SELECTED PER PLANS, VERIFY W/. OWNER –PROVIDE POWER AS REQ'D. (CRC 321.1)
A/C CONDENSER / HEAT PUMP -TO BE IN COMPLIANCE OF SECTION 307.3 OF CPC AS
SELECTED, VERIFY W/. OWNER -SIZE TBD, SEE T-24 ENERGY REPORT FOR MORE INFO –
PROVIDE POWER AND SOUND DAMPENING PAD AS REQ’D. –INSTALL AND MAINTAIN
REQUIRED CLEARANCES PER MFGR. INSTRUCTION
FAU -PROVIDE GAS S.O., POWER, AND VENTING AS REQ'D. BY MFG'R. –INSTALL PER
MFGR. INSTRUCTION
ROOF/DECK DRAIN -PER CHAPTER 11 OF CPC -SIZE THE DRAIN AND PIPING PER TABLE
1103.1 AND 1103.2 OF CPC –ROOF DRAIN SHALL HAVE DOMED STRAINER (CPC 1102.2) –
REF. DETAIL 11/AD-1.0
OVERFLOW OR EMERGENCY DRAIN -PER CHAPTER 11 OF CPC -COPPER OR EQ., INSTALL
PER MFGR. INSTRUC., SLOPED TOWARD IN-WALL DRAIN INLETS –SLOPE AND SIZE PER
TABLE 1103.3 OF CPC –REF. DTL. 11/AD-1.0
UP
20R@7 1/2"
STAIRS -MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL OF NOT
LESS THAN 1 FOOT CANDLE AS MEASURED AT THE CENTER OF TREADS AND
LANDING WITH ARTIFICIAL LIGHTING (R303.7) -REF. DTL. 3/AD-1
ELEVATOR -PRIVATE RESIDENCE ELEVATOR IN COMPLIANCE W/. ASME A17.1/CSA B44
AS SELECTED PER PLANS, VERIFY W/. OWNER –PROVIDE POWER AS REQUIRED (CRC
R321.1)
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
KEYNOTESB
ANNOTATION LEGENDA
BRANDON ARCHITECTS
01.28.22
SECOND LEVEL
FLOOR PLANMITCHELL RESIDENCETOM & KELLY MITCHELL
141 GALAXY DR.
NEWPORT BEACH, CA 92660
CDP FIRST CHECK
2631 WAVERLY DR.
NEWPORT BEACH, CA 92663
A-2.1
TBD
BRIAN JOWETT
1/4" = 1'-0"1 SECOND LEVEL FLOOR PLAN
1 PROPERTY LINE
2 FRONT YARD SETBACK
3 SIDE YARD SETBACK
4 REAR YARD SETBACK
5 DOWNSPOUT - ALUMINUM W/. KYNAR FINISH OR EQUIV. - AS SEL. (ARCH. TO APPROVE)
6 GUTTER - ALUMINUM W/. KYNAR FINISH, SHAPE AS SEL. - PROVIDE SHOP DWGS. TO ARCH.
7 BATHTUB - FREE-STANDING, AS SELECTED (VERIFY LOC'N. OF FIXTURES W/. OWNER)
8 CUSTOM SHOWER SEAT PER I.D.
9 BATHTUB & SHOWER - PROVIDE TILE W/. CEMENT BACKING MIN. 72"" HIGH (R307.2)
10 INTERIOR GUARDRAIL - MIN. 42" HIGH - MATERIAL AS SELECTED, <4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
11 INTERIOR STAIR MOUNTED HANDRAIL - 34"-38" ABV. NOSING, REF. DTL. 4/AD-1
12 STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT
CANDLE (CBC 1205.4) REF. DTL. 3/AD-1
13 BELOW-WINDOW PLANTER BOXES
14 CHANNEL DRAIN - COPPER OR EQUIV., INSTALL PER MFGR. SPECS, SLOPED TO DRAINS & OVERFLOW DRAINS, REF. DTL. 6, 12 /
AD-1.0
15 SHOWER - PROVIDE TILE W/. CEMENT BACKING MIN. 72" HIGH (R307.2)
16 PROVIDE FLOOR DRAIN IN LAUNDRY ROOM
17 WINDOW TO MEET EGRESS REQUIREMENTS - REF. DOOR AND WINDOW NOTES #6, SHT. A-7.0
18 FIREPLACE - PREFABRICATED, GAS ONLY, 'DAVINCI - ISLAND' - ANSI Z21.50B-2014 [DTL. 22/AD-1] (FACTORY BUILT
FIREPLACES, CHIMNEYS, AND ALL OF THEIR COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE W/. THEIR
LISTING AND MFG'R. INSTALLATION INSTRUCTIONS. GASEOUS FUEL BURNING PAN MUST BE PERMANENTLY ANCHORED TO
THE FIREBOX. FIREPLACE MUST COMPLY W/. THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES.)
19 STANDING SEAM METAL ROOFING - REF. MAT. SCHEDULE SHT. A-4.0
20 WOOD SHINGLE ROOFING - REF. MAT. SCHEDULE SHT. A-4.0
21 EXTERIOR GUARDRAIL - MIN. 42" HEIGHT - 4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
NO. REVISION DATE
PA2022-027
A-4.1
A-4.0
A-4.02
A-4.1
2
1
1
1
A-5.0
1
A-5.0
1
1
2
2
3 3
37
46
R @ 0' -6 3/32"18
S.Y.S.B.4' - 0"R.Y.S.B.
10' - 0"S.Y.S.B.4' - 0"HOA SECOND L EVEL S.B.5' - 0 "
F.Y.S.B.
10 ' - 0"TYP.11"CLR.4' - 7 1/2"CLR.4' - 11"CLR.
4' - 3 5/8"
CLR.
4' - 3 5/8"
DWN.
7:12
7:12
7:12
7:12
7:12 7:12 3:127:127:127:127:12 7:12
7:127:12
STAIRS LANDING
ROOF DECK
34.25' F.F.
OPEN TO BELOW
2% SLOPE MIN.
12
13
1
4
1 3
5
6
6
7
8
9
9
10
11
11
12
2
A-5.0
2
A-5.0
397:127:127:12
4:127:12 4.5:127:127:123:129
138
63 62 61
14
14
14
14
15
15
15
14 15
14
1514
14
3.5:12
ROOM TAGROOM NAME
1
A-5.0
1 1
?
1
1
A-4.0
1
1 1
1
ELEVATION / SECTION INDICATOR
AD-1.0
1 CALL-OUT TAG
10.00'SPOT ELEVATION
KEYNOTE TAG
REVISION TAG
DOOR / WINDOW / WINDOW WALL TAG
FIRE RATED CEILING ASS'Y -REF. DTLS. 7/AD-1.0
1-HR RATED INT CONDITION -REF. DTLS. 7/AD-1.0
1-HR RATED EXT CONDITION -REF. DTLS. 7/AD-1.0
STRUCTURAL STEEL COLUMN PER STRUCT., REF. STRUTC.
DWGS, -PAINT AND SEAL AS REQUIRED –ARCH. TO APPV.
COLOR FOR EXPOSED STEEL COLUMNS
STRUCTURAL WOOD POST/COLUMN COLUMN -PER STRUCT., REF. STRUTC. DWGS, -
PAINT, STAIN AND SEAL AS REQUIRED –ARCH. TO APPV. PAINT COLOR FOR EXPOSED
WOOD POST/COLUMN, IF TO BE STAINED PROVIDE STAINED SAMPLE FOR ARCH,
APPROVAL
DOORS -AS SPECIFIED, SEE WINDOW SCHEDULE AND GENERAL NOTES ON SHEET A-7.0 -
SHGC & U-FCTOR PER T-24 ENERGY REPORT – SEE SHEET AD-2.0 FOR JAMB, HEAD AND
THRESHOLD DETAILS, PROVIDE FLASHING AND WATERPROOFING AT DOOR OPENING PER
THE DOOR MFGR. INSTRUCTION AND/OR FLASHING MFGR. INSTRUCTION PER SECTIONS
R609.1 & R703.4 OF CRC
WINDOW -AS SPECIFIED, SEE WINDOW SCHEDULE AND GENERAL NOTES ON
SHEET A-7.0 -SHGC & U-FCTOR PER T-24 ENERGY REPORT – SEE SHEET
AD-2.0 FOR JAMB, HEAD AND SILL DETAILS, PROVIDE FLASHING AND
WATERPROOFING AT WINDOW OPENING PER THE WINDOW MFGR.
INSTRUCTION AND/OR FLASHING MFGR. INSTRUCTION PER SECTIONS R609.1
& R703.4 OF CRC
KITCHEN RANGE W/. EXHAUST HOOD -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
PROVIDE POWER AND GAS AS REQUIRED -30”MIN. VERTICAL CLEARANCE TO ANY
COMBUSTIBLE MATERIAL ABV. COOKING TOP (CMC 920.3.2) –EXHAUST HOOD TO HAVE
EXHAUST RATE OF MIN. 100 CFM AND VENT TO OUTDOOR , HOOD DUCTS TO BE OF
METAL WITH SMOOTH INTERIOR FINISH PER SECTION 504.3 OF CMC
KITCHEN/BAR SINK -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –SINK TO COMPLY
W/. REQUIREMENT OF SECTION 420.0 OF CPC AND HAVE A MAX FLOW RATE OF 1.8 GPM
@ 60 PSI PER SECTION 4.303.1 OF CALGREEN –TRAP AND VENT FOR ISLAND SINK AND
SIMILAR EQUIPMENT SHALL BE PER SECTION 909.0 OF CPC
VANITY SINK -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
LAVATORY TO HAVE 24”MIN. CLEAR SPACE IN FRONT OF IT.(CPC 402.5)
W/. MAXIMUM FLOW RATE OF 1.2 GPM @ 60 PSI AND MIN. FLOW RATE OF
0.8 GPM @ 20 PSI PER SECTION 4.303.1 OF CALGREEN
WASHER (W) / DRYER (D) / STACKED (W/D)-AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER –PROVIDE POWER , GAS, WATER SUPPLY & DRAINAGE AS REQUIRED -THE
CLOTHES DRYERS VENT SHALL BE OF A RIGID METALLIC MATERIAL AND HAVE A
BACKDRAFT DAMPER (CMC 504.4) AND SHALL NOT EXCEED 14-FEET IN OVERALL LENGTH
WITH MAX. OF TWO (2) 90-DEGREE ELBOW, SUBTRACT 2-FEET FOR EACH ADDITIONAL 90-
DEGREE ELBOW. SEE WASHER & DRYER NOTES, REF. T-1.1.
REFRIGERATOR (REF) / FREEZER (FRZ) -AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER –PROVIDE POWER AND WATER SUPPLY AS REQUIRED
BUILT-IN APPLIANCE / DISHWASHER (DW) / TRASH COMPACTOR (TR)-AS SELECTED PER
I.D., VERIFY W/. I.D. & OWNER –PROVIDE POWER , WATER SUPPLY & DRAINAGE PIPE AS
REQUIRED
TOILET -WATER CLOSET SHALL BE IN COMPLIANCE OF SECTION 411.0 OF CPC AND HAS
MAX EFFECTIVE FLUSH RATE OF 1.28 GAL. PER FLUSH (CPC 411.2). WATER CLOSETS
CLR. TO BE 24”IN FRONT AND 15”FROM ITS CENTER TO ANY SIDE WALL OR
OBSTRUCTION. (CPC 402.5 & CRC R307) –REF. CALGREEN NOTES ON T SHTS. FOR MAX
FLOW RATE
CASEWORK, TALL CABINET -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER
CASEWORK, BASE CABINET W/. COUNTERTOP -AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER
CASEWORK, UPPER CABINET/SHELVES -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER
BUILT-IN CLOSET -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER
FIREPLACE -FACTORY-BUILT DIRECT VENT GAS FIREPLACE W/. SEALED COMBUSTION
(CALGREEN 4.503) -FACTORY-BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR
COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING
AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. (CRC R1004.1)
ELEVATOR -PRIVATE RESIDENCE ELEVATOR IN COMPLIANCE W/. ASME A17.1/CSA B44
AS SELECTED PER PLANS, VERIFY W/. OWNER –PROVIDE POWER AS REQ'D. (CRC 321.1)
A/C CONDENSER / HEAT PUMP -TO BE IN COMPLIANCE OF SECTION 307.3 OF CPC AS
SELECTED, VERIFY W/. OWNER -SIZE TBD, SEE T-24 ENERGY REPORT FOR MORE INFO –
PROVIDE POWER AND SOUND DAMPENING PAD AS REQ’D. –INSTALL AND MAINTAIN
REQUIRED CLEARANCES PER MFGR. INSTRUCTION
FAU -PROVIDE GAS S.O., POWER, AND VENTING AS REQ'D. BY MFG'R. –INSTALL PER
MFGR. INSTRUCTION
ROOF/DECK DRAIN -PER CHAPTER 11 OF CPC -SIZE THE DRAIN AND PIPING PER TABLE
1103.1 AND 1103.2 OF CPC –ROOF DRAIN SHALL HAVE DOMED STRAINER (CPC 1102.2) –
REF. DETAIL 11/AD-1.0
OVERFLOW OR EMERGENCY DRAIN -PER CHAPTER 11 OF CPC -COPPER OR EQ., INSTALL
PER MFGR. INSTRUC., SLOPED TOWARD IN-WALL DRAIN INLETS –SLOPE AND SIZE PER
TABLE 1103.3 OF CPC –REF. DTL. 11/AD-1.0
UP
20R@7 1/2"
STAIRS -MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL OF NOT
LESS THAN 1 FOOT CANDLE AS MEASURED AT THE CENTER OF TREADS AND
LANDING WITH ARTIFICIAL LIGHTING (R303.7) -REF. DTL. 3/AD-1
ELEVATOR -PRIVATE RESIDENCE ELEVATOR IN COMPLIANCE W/. ASME A17.1/CSA B44
AS SELECTED PER PLANS, VERIFY W/. OWNER –PROVIDE POWER AS REQUIRED (CRC
R321.1)
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
KEYNOTESB
ANNOTATION LEGENDA
BRANDON ARCHITECTS
01.28.22
ROOF DECK FLOOR
PLANMITCHELL RESIDENCETOM & KELLY MITCHELL
141 GALAXY DR.
NEWPORT BEACH, CA 92660
CDP FIRST CHECK
2631 WAVERLY DR.
NEWPORT BEACH, CA 92663
A-2.2
TBD
BRIAN JOWETT
NO. REVISION DATE
1/4" = 1'-0"1 ROOF DECK FLOOR PLAN
1 PROPERTY LINE
2 FRONT YARD SETBACK
3 SIDE YARD SETBACK
4 REAR YARD SETBACK
5 SKYLIGHT - SIZE AS DIM. - 'SKYCO' ICC #ESR-3837 OR EQUIV. (REF. DTLS.)
6 INTERIOR GUARDRAIL - MIN. 42" HIGH - MATERIAL AS SELECTED, <4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
7 INTERIOR STAIR MOUNTED HANDRAIL - 34"-38" ABV. NOSING, REF. DTL. 4/AD-1
8 A/C. CONDENSER UNIT - SIZE TBD - PROVIDE POWER AND SOUND DAMPENING PAD AS REQ'D. (SOUND ATTENUATION
REQ'D. PER SECTION 10.26.045 N.B.M.C. UNDER SEPARATE PERMIT & PLAN CHECK)
9 CHIMNEY CAP/SPARK ARRESTOR - AS SELECTED (NOTE: DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT THE
TERMINATION OF FACTORY BUILT CHIMNEYS EXCEPT WHERE SUCH SHROUDS ARE LISTED AND LABELED FOR USE WITH
THE SPECIFIC FAC. BLT. CHIMNEY SYSTEM AND ARE INSTALLED IN ACCORDANCE W/. MFGR. INST. INSTRUCTIONS. CMC
802.4.2.4)
10 GUTTER - ALUMINUM W/. KYNAR FINISH, SHAPE AS SEL. - PROVIDE SHOP DWGS. TO ARCH.
11 FLAT COOL ROOF, CLASS 'A' - COLOR AS SELECTED - TPO MEMBRANE - REF. MAT. SCHEDULE SHT. A-4.0
12 STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT
CANDLE (CBC 1205.4) REF. DTL. 3/AD-1
13 CHANNEL DRAIN - COPPER OR EQUIV., INSTALL PER MFGR. SPECS, SLOPED TO DRAINS & OVERFLOW DRAINS, REF. DTL.
6, 12 / AD-1.0
14 WOOD SHINGLE ROOFING - REF. MAT. SCHEDULE SHT. A-4.0
15 STANDING SEAM METAL ROOFING - REF. MAT. SCHEDULE SHT. A-4.0
PA2022-027
UP
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE
NEAREST 1/8" AND INTERIOR PARTITIONS ARE DIMENSIONED FROM FACE OF STRUCTURE TO FACE OF STRUCTURE (F.O.S.) U.N.O. -
CONTACT ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
ROUGH FRAMING:
ALL EXTERIOR WALLS TO BE FRAMED W/. 2X6 STUD MIN. U.N.O.
USE 2X6 MINIMUM STUDS FOR PLUMBING WALLS
SECOND AND THIRD FLOOR PLYWOOD TO BE 1-1/8"
ENTIRE EXTERIOR TO BE SHEATHED WITH 1/2" PLYWOOD
DOORS AND WINDOWS WILL TYPICALLY BE RECESSED FROM EXTERIOR WALL PLANE. VERIFY ALL ROUGH OPENING DIMENSIONS
WITH DOOR AND WINDOW MFGR. ROUGH OPENING MAY NEED TO BE OVERSIZED TO ACCOUNT FOR ADDITIONAL FRAMING. SEE
SHT. AD-2.0 FOR TYP. RECESSED CONDITIONS.
GARAGE FLOOR:
GARAGE FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTIBLE MATERIAL.THE AREA OF FLOOR USED FOR PARKING OF
AUTOMOBILES OR OTHER VEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS TO A DRAIN OR TOWARD THE
MAIN VEHICLE ENTRY DOORWAY. (R309.1)
PLUMBING:
1. SUPPORT ALL WALL-HUNG FIXTURES WITH METAL SUPPORTING MEMBERS TO PREVENT ANY STRAIN TRANSMISSION TO THE
CONNECTIONS. FRAMING AFFIXED SUPPORTS FOR OFF-THE-FLOOR WATER CLOSETS WITH CONCEALED TANKS SHALL COMPLY
WITH ASME A112.6.2. SECURE FLUSH TANK AND SIMILAR APPURTENANCES WITH APPROVED NON-CORROSIVE SCREW OR BOLTS.
(CPC 402.5)
2. THE NET AREA OF THE SHOWER ENCLOSURE SHALL BE 1,024 SQ. INCHES (7.1 SQ. FT.) OR MORE IN THE CLEAR FLOOR AREA,
AND SHALL ALSO BE CAPABLE OF ENCOMPASSING A 30-INCH DIAMETER CIRCLE. (CPC 408.6)
3. THE WATER HEATER BURNER AND BURNER-IGNITION DEVICE TO BE AT LEAST 18-INCHES ABOVE THE FLOOR, IF LOCATED IN A
GARAGE AND IN ADJACENT SPACES THAT OPEN TO THE GARAGE. FOR WATER HEATER IN THE GARAGE OR OTHER AREAS SUBJECT
TO MECHANICAL DAMAGE PROVIDE A PROTECTIVE BARRIER OR ELEVATE THE APPLIANCE TO BE OUT OF THE NORMAL PATH OF
THE VEHICLE. (CPC 507.13)
4. ANCHOR OR STRAP THE WATER HEATER(S) TO RESIST HORIZ. DISPLACEMENT DUE TO THE EARTHQUAKE. STRAPPING SHOULD
BE AT THE UPPER AND LOWER ONE THIRD (1/3) POINTS OF THE APPLIANCE HEIGHT. MAINTAIN A MIN. 4-INCHES ABOVE THE
CONTROLS WITH STRAPPING AT LOWER POINT.
WOOD OR WOODBASED PRODUCTS NOTE:
WOOD OR WOODBASE PRODUCT SHALL BE OF A NATURAL DURABLE OR PRESERVATIVE-TREADED WOOD IN ACCORDANCE WITH
AWPA U1 FOR THE SPECIES, PRODUCT, PRESERVATIVE AND END USE IN THE FOLLOWING LOCATIONS:
1. WOOD JOISTS OR THE BOTTOM OF A WOOD STRUCTURAL FLOOR WHEN CLOSER THAN 18 INCHES (457 MM) OR WOOD GIRDERS
WHEN CLOSER THAN 12 INCHES (305 MM) TO THE EXPOSED GROUND IN CRAWL SPACES OR UNEXCAVATED AREA LOCATED
WITHIN THE PERIPHERY OF THE BUILDING FOUNDATION.
2. WOOD FRAMING MEMBERS THAT REST ON CONCRETE OR MASONRY EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8
INCHES (203 MM) FROM THE EXPOSED GROUND.
3. SILLS AND SLEEPERS ON A CONCRETE OR MASONRY SLAB THAT IS IN DIRECT CONTACT WITH THE GROUND UNLESS
SEPARATED FROM SUCH SLAB BY AN IMPERVIOUS MOISTURE BARRIER.
4. THE ENDS OF WOOD GIRDERS ENTERING EXTERIOR MASONRY OR CONCRETE WALLS HAVING CLEARANCES OF LESS THAN 1/2
INCH (12.7 MM) ON TOPS, SIDES AND ENDS.
5. WOOD SIDING, SHEATHING AND WALL FRAMING ON THE EXTERIOR OF A BUILDING HAVING A CLEARANCE OF LESS THAN 6
INCHES (152 MM) FROM THE GROUND OR LESS THAN 2 INCHES (51 MM) MEASURED VERTICALLY FROM CONCRETE STEPS,
PORCH SLABS, PATIO SLABS AND SIMILAR HORIZONTAL SURFACES EXPOSED TO THE WEATHER.
6. WOOD STRUCTURAL MEMBERS SUPPORTING MOISTURE-PERMEABLE FLOORS OR ROOFS THAT ARE EXPOSED TO THE
WEATHER, SUCH AS CONCRETE OR MASONRY SLABS, UNLESS SEPARATED FROM SUCH FLOORS OR ROOFS BY AN IMPERVIOUS
MOISTURE BARRIER.
7. WOOD FURRING STRIPS OR OTHER WOOD FRAMING MEMBERS ATTACHED DIRECTLY TO THE INTERIOR OF EXTERIOR MASONRY
WALLS OR CONCRETE WALLS BELOW GRADE EXCEPT WHERE AN APPROVED VAPOR RETARDER IS APPLIED BETWEEN THE WALL
AND THE FURRING STRIPS OR FRAMING MEMBERS.
*HERS VERIFICATION REQUIRED-REFERENCE T-24.1
ROOM TAGROOM NAME
1
1
1
1
10.00'SPOT ELEVATION
REVISION TAG
DOOR TAG
WINDOW WALL TAG
WINDOW TAG
STRUCTURAL STEEL COLUMN PER STRUCT., REF. STRUTC.
DWGS, -PAINT AND SEAL AS REQUIRED –ARCH. TO APPV.
COLOR FOR EXPOSED STEEL COLUMNS
STRUCTURAL WOOD POST/COLUMN COLUMN -PER STRUCT., REF. STRUTC. DWGS, -
PAINT, STAIN AND SEAL AS REQUIRED –ARCH. TO APPV. PAINT COLOR FOR EXPOSED
WOOD POST/COLUMN, IF TO BE STAINED PROVIDE STAINED SAMPLE FOR ARCH,
APPROVAL
KITCHEN RANGE W/. EXHAUST HOOD -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
PROVIDE POWER AND GAS AS REQUIRED -30”MIN. VERTICAL CLEARANCE TO ANY
COMBUSTIBLE MATERIAL ABV. COOKING TOP (CMC 920.3.2) –EXHAUST HOOD TO HAVE
EXHAUST RATE OF MIN. 100 CFM AND VENT TO OUTDOOR , HOOD DUCTS TO BE OF
METAL WITH SMOOTH INTERIOR FINISH PER SECTION 504.3 OF CMC
KITCHEN/BAR SINK -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –SINK TO COMPLY
W/. REQUIREMENT OF SECTION 420.0 OF CPC AND HAVE A MAX FLOW RATE OF 1.8 GPM
@ 60 PSI PER SECTION 4.303.1 OF CALGREEN –TRAP AND VENT FOR ISLAND SINK AND
SIMILAR EQUIPMENT SHALL BE PER SECTION 909.0 OF CPC
VANITY SINK -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
LAVATORY TO HAVE 24”MIN. CLEAR SPACE IN FRONT OF IT.(CPC 402.5)
W/. MAXIMUM FLOW RATE OF 1.2 GPM @ 60 PSI AND MIN. FLOW RATE OF
0.8 GPM @ 20 PSI PER SECTION 4.303.1 OF CALGREEN
WASHER (W) / DRYER (D) / STACKED (W/D)-AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER –PROVIDE POWER , GAS, WATER SUPPLY & DRAINAGE AS REQUIRED -THE
CLOTHES DRYERS VENT SHALL BE OF A RIGID METALLIC MATERIAL AND HAVE A
BACKDRAFT DAMPER (CMC 504.4) AND SHALL NOT EXCEED 14-FEET IN OVERALL LENGTH
WITH MAX. OF TWO (2) 90-DEGREE ELBOW, SUBTRACT 2-FEET FOR EACH ADDITIONAL 90-
DEGREE ELBOW. SEE WASHER & DRYER NOTES, REF. T-1.1.
TOILET -WATER CLOSET SHALL BE IN COMPLIANCE OF SECTION 411.0 OF CPC AND HAS
MAX EFFECTIVE FLUSH RATE OF 1.28 GAL. PER FLUSH (CPC 411.2). WATER CLOSETS
CLR. TO BE 24”IN FRONT AND 15”FROM ITS CENTER TO ANY SIDE WALL OR
OBSTRUCTION. (CPC 402.5 & CRC R307) –REF. CALGREEN NOTES ON T SHTS. FOR MAX
FLOW RATE
FIREPLACE -FACTORY-BUILT DIRECT VENT GAS FIREPLACE W/. SEALED COMBUSTION
(CALGREEN 4.503) -FACTORY-BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR
COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING
AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. (CRC R1004.1)
A/C CONDENSER / HEAT PUMP -TO BE IN COMPLIANCE OF SECTION 307.3 OF CPC AS
SELECTED, VERIFY W/. OWNER -SIZE TBD, SEE T-24 ENERGY REPORT FOR MORE INFO –
PROVIDE POWER AND SOUND DAMPENING PAD AS REQ’D. –INSTALL AND MAINTAIN
REQUIRED CLEARANCES PER MFGR. INSTRUCTION
FAU -PROVIDE GAS S.O., POWER, AND VENTING AS REQ'D. BY MFG'R. –INSTALL PER
MFGR. INSTRUCTION
RECESSED MAIN SERVICE PANEL -400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE
OF PANEL TO ANY OBSTRUCTION) –GC TO COORDINATE W/. UTILITY COMPANY
ROOF/DECK DRAIN -PER CHAPTER 11 OF CPC -SIZE THE DRAIN AND PIPING PER TABLE
1103.1 AND 1103.2 OF CPC –ROOF DRAIN SHALL HAVE DOMED STRAINER (CPC 1102.2) –
REF. DETAIL 11/AD-1.0
OVERFLOW OR EMERGENCY DRAIN -PER CHAPTER 11 OF CPC -COPPER OR EQ., INSTALL
PER MFGR. INSTRUC., SLOPED TOWARD IN-WALL DRAIN INLETS –SLOPE AND SIZE PER
TABLE 1103.3 OF CPC –REF. DTL. 11/AD-1.0
2X4 STUD WALL
2X6 STUD WALL
2X8 STUD WALL
2X10 STUD WALL
EXT. POCKET DOOR WALL - TYP. 2X6 EXT. FRMG. AND 2X4 INTERIOR FRAMING W/.
DOUBLE TOP PLATE AND SINGLE SILL PLATE U.N.O., MIN. AIR SPACE/DOOR POCKET
TO BE VERIFIED W/. DOOR MFGR. - STUDS MIN. SPACING PER STRUCT. AND EXT.
FINISH MFGR. INSTRUCTION AND/OR LISTING –SEE EXT. WALL DETAILS AND STRUCT.
DWGS
CONCRETE WALL -12”REINFORCED CAST IN PLACE CONCRETE WALL TYP. U.N.O. PER
STRUCT., REF. STRCUTC. DWGS. –FOR BASEMENT/RETAINING CONCRETE WALL
PROVIDE WATERPROOFING OR DAMPPROOFING AND DRAINAGE AS REQUIRED PER
SECTION R406.1 & R406.2, REF. SOILS REPORT,WATERPROOFING & DAMPROOFING
NOTES ON SHEET T-1.1 –EXPOSED SURFACES TO HAVE TROWELED SMOOTH FINISH
WITH A LIGHT GRAY COLOR, PROVIDE SAMPLE FOR ARCH. APPROVAL
SLAB/FRAMING DEPRESSION -SEE STRUCT. DWGS. FOR THE RECESSION DETAILS -
FOR RECESSION SPECIFIC TO EQUIPMENT OR ASSEMBLY VERIFY THE REQUIRED
RECESSION W/. MFGR. OR FABRICATOR –SHOWER RECESSION TO BE VERIFIED W/.
I.D.
SEE SHEET AD-2.0 FOR THE TYPICAL DEPRESSION OF DOORS AND WINDOWS, VERIFY
ALL DEPRESSIONS W/. MFGR.
STUDS MIN. SPACING PER STRUCT. AND EXT. FINISH MFGR.
INSTRUCTION AND/OR LISTING –SEE EXT. WALL DETAILS AND
STRUCT. DWGS
VERTICAL STORM DRAIN PIPE IN-WALL / OVERFLOW -MTL. PIPE PER
CHAPTER 11 OF CPC, SIZE PER TABLE 1103.1 (MIN. 2”DIA. PIPE & TYP. 3”DIA. PIPE) –
SEE CIVIL DWGS. FOR TERMINATION DTLS. ABV. OR BLW. GROUND. VERIFY ALL
TERMINATION POINTS, TYPE AND DETAILS W/. CIVIL PRIOR TO POURING THE CONCRETE
SLAB
OVERFLOW
DRAINLINE
A-4.1
A-4.0
A-4.02
A-4.1
2
1
1
1
A-5.0
1
A-5.0
1
1
2
2
3 3
2
A-5.0
2
A-5.0
3' - 6 7/8"7' - 11 1/8"81' - 4 3/8"11' - 3 1/4"4' - 9"
16' - 6 1/2"5' - 9 1/4"17' - 5 1/8"19' - 3 3/8"22' - 4 1/8"
3' - 2 1/8"2' - 4 3/4"5' - 8"2' - 4 3/4"2' - 11 1/8"
5' - 9 1/4"3' - 2 1/4"2' - 6 1/4"1' - 2 5/8"10' - 6"
11 1/2"2' - 10"
5 1/4"
1' - 4 5/8"8' - 8 7/8"1' - 11 1/8"3' - 2 7/8"16' - 0 1/2"1' - 8"14' - 7 3/4"1' - 6 3/4"1' - 11 3/4"1' - 8 1/8"9 3/4"
4' - 3 1/4"3' - 6 7/8"6' - 8"3' - 6 7/8"4' - 3 1/4"10' - 11 1/2"50' - 6"4' - 2 3/4"13' - 4 3/8"17' - 0 7/8"20' - 0 3/4"4' - 9 3/8"2' - 0"2' - 0"4' - 4 5/8"2 1/2"3' - 9 1/8"2' - 5 1/8"1' - 4 3/4"8' - 0"1' - 6"1' - 5 7/8"17' - 0"1' - 7"10' - 0 7/8"74' - 9"15' - 8 7/8"
17' - 7"3' - 9 3/8"8 3/4"9' - 0"9 1/8"3' - 10 5/8"3' - 7 1/8"6' - 3 1/4"7' - 3 1/4"13' - 5 7/8"8' - 4 3/4"3' - 10 3/4"1' - 9 3/4"26' - 0 5/8"6 1/8"34' - 10 7/8"4' - 2 3/4"16' - 4 1/2"18' - 6 3/8"2' - 0 1/4"12' - 0"2' - 4 1/4"2' - 10 5/8"2' - 3"2' - 3"5' - 4 1/4"5' - 9 1/2"1' - 9 3/4"14' - 6"1' - 9 3/4"4 3/4"21' - 3 3/4"6' - 6 1/2"4' - 0"1' - 7 7/8"3' - 8 5/8"
3' - 11 3/8"6' - 4 3/8"4' - 8"6' - 3 1/4"5' - 8 1/2"10' - 10 5/8"10"6' - 4 5/8"11' - 5 3/8"1' - 8 5/8"1' - 2"12' - 10 3/8"2' - 4 3/8"4' - 3 3/4"4' - 6 5/8"8' - 3"6' - 2 5/8"1' - 11 7/8"11' - 0 5/8"5' - 6 1/2"2' - 9 3/8"2' - 6"9 3/4"2' - 1 3/4"4' - 3 1/2"5' - 1 3/4"1' - 4 1/2"12' - 4 1/4"7 3/4"17' - 8 1/4"1' - 4 1/2"1' - 9 7/8"12' - 0"2' - 0 1/4"1' - 7 1/4"14' - 2 7/8"1' - 5 3/4"1' - 8 7/8"CASITA
BATH 1
W.I.C.
LAUNCH FORMAL DINING
HALLWAY
POWDER
PANTRY
STAIR
KITCHEN
GREAT ROOM
FOYER
CASUAL DINING
3-CAR
GARAGE
3" SLAB DEPRESSION FOR SHOWER -
VERIFY W/. G.C. & REF. STRUCT. DWGS.
SLAB DEPRESSION FOR
FIREPLACE -VERIFY W/. G.C. &
MFGR. & REF. STRUCT. DWGS.
SLAB DEPRESSION FOR DOOR
SYSTEM -VERIFY W/. G.C. & MFGR. &
REF. STRUCT. DWGS
SLAB DEPRESSION FOR
FIREPLACE -VERIFY W/.
G.C. & MFGR. & REF.
STRUCT. DWGS.
SLAB DEPRESSION FOR DOOR
SYSTEM -VERIFY W/. G.C. &
MFGR. & REF. STRUCT. DWGS
SLAB DEPRESSION FOR DOOR
SYSTEM -VERIFY W/. G.C. &
MFGR. & REF. STRUCT. DWGS
SLAB DEPRESSION FOR DOOR
SYSTEM -VERIFY W/. G.C. &
MFGR. & REF. STRUCT. DWGS6' - 3"6' - 3 3/8"5' - 1 3/4"1' - 4"13' - 0 1/2"DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
ANNOTATION LEGEND
GENERAL NOTESA
B
01.28.22
FIRST LEVEL
DIMENSION PLANMITCHELL RESIDENCETOM & KELLY MITCHELL
141 GALAXY DR.
NEWPORT BEACH, CA 92660
CDP FIRST CHECK
2631 WAVERLY DR.
NEWPORT BEACH, CA 92663
A-2.3
TBD
BRIAN JOWETT
NO. REVISION DATE
1/4" = 1'-0"1 FIRST LEVEL DIMENSION PLAN
PA2022-027
DNUP
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE
NEAREST 1/8" AND INTERIOR PARTITIONS ARE DIMENSIONED FROM FACE OF STRUCTURE TO FACE OF STRUCTURE (F.O.S.) U.N.O. -
CONTACT ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
ROUGH FRAMING:
ALL EXTERIOR WALLS TO BE FRAMED W/. 2X6 STUD MIN. U.N.O.
USE 2X6 MINIMUM STUDS FOR PLUMBING WALLS
SECOND AND THIRD FLOOR PLYWOOD TO BE 1-1/8"
ENTIRE EXTERIOR TO BE SHEATHED WITH 1/2" PLYWOOD
DOORS AND WINDOWS WILL TYPICALLY BE RECESSED FROM EXTERIOR WALL PLANE. VERIFY ALL ROUGH OPENING DIMENSIONS
WITH DOOR AND WINDOW MFGR. ROUGH OPENING MAY NEED TO BE OVERSIZED TO ACCOUNT FOR ADDITIONAL FRAMING. SEE
SHT. AD-2.0 FOR TYP. RECESSED CONDITIONS.
GARAGE FLOOR:
GARAGE FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTIBLE MATERIAL.THE AREA OF FLOOR USED FOR PARKING OF
AUTOMOBILES OR OTHER VEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS TO A DRAIN OR TOWARD THE
MAIN VEHICLE ENTRY DOORWAY. (R309.1)
PLUMBING:
1. SUPPORT ALL WALL-HUNG FIXTURES WITH METAL SUPPORTING MEMBERS TO PREVENT ANY STRAIN TRANSMISSION TO THE
CONNECTIONS. FRAMING AFFIXED SUPPORTS FOR OFF-THE-FLOOR WATER CLOSETS WITH CONCEALED TANKS SHALL COMPLY
WITH ASME A112.6.2. SECURE FLUSH TANK AND SIMILAR APPURTENANCES WITH APPROVED NON-CORROSIVE SCREW OR BOLTS.
(CPC 402.5)
2. THE NET AREA OF THE SHOWER ENCLOSURE SHALL BE 1,024 SQ. INCHES (7.1 SQ. FT.) OR MORE IN THE CLEAR FLOOR AREA,
AND SHALL ALSO BE CAPABLE OF ENCOMPASSING A 30-INCH DIAMETER CIRCLE. (CPC 408.6)
3. THE WATER HEATER BURNER AND BURNER-IGNITION DEVICE TO BE AT LEAST 18-INCHES ABOVE THE FLOOR, IF LOCATED IN A
GARAGE AND IN ADJACENT SPACES THAT OPEN TO THE GARAGE. FOR WATER HEATER IN THE GARAGE OR OTHER AREAS SUBJECT
TO MECHANICAL DAMAGE PROVIDE A PROTECTIVE BARRIER OR ELEVATE THE APPLIANCE TO BE OUT OF THE NORMAL PATH OF
THE VEHICLE. (CPC 507.13)
4. ANCHOR OR STRAP THE WATER HEATER(S) TO RESIST HORIZ. DISPLACEMENT DUE TO THE EARTHQUAKE. STRAPPING SHOULD
BE AT THE UPPER AND LOWER ONE THIRD (1/3) POINTS OF THE APPLIANCE HEIGHT. MAINTAIN A MIN. 4-INCHES ABOVE THE
CONTROLS WITH STRAPPING AT LOWER POINT.
WOOD OR WOODBASED PRODUCTS NOTE:
WOOD OR WOODBASE PRODUCT SHALL BE OF A NATURAL DURABLE OR PRESERVATIVE-TREADED WOOD IN ACCORDANCE WITH
AWPA U1 FOR THE SPECIES, PRODUCT, PRESERVATIVE AND END USE IN THE FOLLOWING LOCATIONS:
1. WOOD JOISTS OR THE BOTTOM OF A WOOD STRUCTURAL FLOOR WHEN CLOSER THAN 18 INCHES (457 MM) OR WOOD GIRDERS
WHEN CLOSER THAN 12 INCHES (305 MM) TO THE EXPOSED GROUND IN CRAWL SPACES OR UNEXCAVATED AREA LOCATED
WITHIN THE PERIPHERY OF THE BUILDING FOUNDATION.
2. WOOD FRAMING MEMBERS THAT REST ON CONCRETE OR MASONRY EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8
INCHES (203 MM) FROM THE EXPOSED GROUND.
3. SILLS AND SLEEPERS ON A CONCRETE OR MASONRY SLAB THAT IS IN DIRECT CONTACT WITH THE GROUND UNLESS
SEPARATED FROM SUCH SLAB BY AN IMPERVIOUS MOISTURE BARRIER.
4. THE ENDS OF WOOD GIRDERS ENTERING EXTERIOR MASONRY OR CONCRETE WALLS HAVING CLEARANCES OF LESS THAN 1/2
INCH (12.7 MM) ON TOPS, SIDES AND ENDS.
5. WOOD SIDING, SHEATHING AND WALL FRAMING ON THE EXTERIOR OF A BUILDING HAVING A CLEARANCE OF LESS THAN 6
INCHES (152 MM) FROM THE GROUND OR LESS THAN 2 INCHES (51 MM) MEASURED VERTICALLY FROM CONCRETE STEPS,
PORCH SLABS, PATIO SLABS AND SIMILAR HORIZONTAL SURFACES EXPOSED TO THE WEATHER.
6. WOOD STRUCTURAL MEMBERS SUPPORTING MOISTURE-PERMEABLE FLOORS OR ROOFS THAT ARE EXPOSED TO THE
WEATHER, SUCH AS CONCRETE OR MASONRY SLABS, UNLESS SEPARATED FROM SUCH FLOORS OR ROOFS BY AN IMPERVIOUS
MOISTURE BARRIER.
7. WOOD FURRING STRIPS OR OTHER WOOD FRAMING MEMBERS ATTACHED DIRECTLY TO THE INTERIOR OF EXTERIOR MASONRY
WALLS OR CONCRETE WALLS BELOW GRADE EXCEPT WHERE AN APPROVED VAPOR RETARDER IS APPLIED BETWEEN THE WALL
AND THE FURRING STRIPS OR FRAMING MEMBERS.
*HERS VERIFICATION REQUIRED-REFERENCE T-24.1
ROOM TAGROOM NAME
1
1
1
1
10.00'SPOT ELEVATION
REVISION TAG
DOOR TAG
WINDOW WALL TAG
WINDOW TAG
STRUCTURAL STEEL COLUMN PER STRUCT., REF. STRUTC.
DWGS, -PAINT AND SEAL AS REQUIRED –ARCH. TO APPV.
COLOR FOR EXPOSED STEEL COLUMNS
STRUCTURAL WOOD POST/COLUMN COLUMN -PER STRUCT., REF. STRUTC. DWGS, -
PAINT, STAIN AND SEAL AS REQUIRED –ARCH. TO APPV. PAINT COLOR FOR EXPOSED
WOOD POST/COLUMN, IF TO BE STAINED PROVIDE STAINED SAMPLE FOR ARCH,
APPROVAL
KITCHEN RANGE W/. EXHAUST HOOD -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
PROVIDE POWER AND GAS AS REQUIRED -30”MIN. VERTICAL CLEARANCE TO ANY
COMBUSTIBLE MATERIAL ABV. COOKING TOP (CMC 920.3.2) –EXHAUST HOOD TO HAVE
EXHAUST RATE OF MIN. 100 CFM AND VENT TO OUTDOOR , HOOD DUCTS TO BE OF
METAL WITH SMOOTH INTERIOR FINISH PER SECTION 504.3 OF CMC
KITCHEN/BAR SINK -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –SINK TO COMPLY
W/. REQUIREMENT OF SECTION 420.0 OF CPC AND HAVE A MAX FLOW RATE OF 1.8 GPM
@ 60 PSI PER SECTION 4.303.1 OF CALGREEN –TRAP AND VENT FOR ISLAND SINK AND
SIMILAR EQUIPMENT SHALL BE PER SECTION 909.0 OF CPC
VANITY SINK -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
LAVATORY TO HAVE 24”MIN. CLEAR SPACE IN FRONT OF IT.(CPC 402.5)
W/. MAXIMUM FLOW RATE OF 1.2 GPM @ 60 PSI AND MIN. FLOW RATE OF
0.8 GPM @ 20 PSI PER SECTION 4.303.1 OF CALGREEN
WASHER (W) / DRYER (D) / STACKED (W/D)-AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER –PROVIDE POWER , GAS, WATER SUPPLY & DRAINAGE AS REQUIRED -THE
CLOTHES DRYERS VENT SHALL BE OF A RIGID METALLIC MATERIAL AND HAVE A
BACKDRAFT DAMPER (CMC 504.4) AND SHALL NOT EXCEED 14-FEET IN OVERALL LENGTH
WITH MAX. OF TWO (2) 90-DEGREE ELBOW, SUBTRACT 2-FEET FOR EACH ADDITIONAL 90-
DEGREE ELBOW. SEE WASHER & DRYER NOTES, REF. T-1.1.
TOILET -WATER CLOSET SHALL BE IN COMPLIANCE OF SECTION 411.0 OF CPC AND HAS
MAX EFFECTIVE FLUSH RATE OF 1.28 GAL. PER FLUSH (CPC 411.2). WATER CLOSETS
CLR. TO BE 24”IN FRONT AND 15”FROM ITS CENTER TO ANY SIDE WALL OR
OBSTRUCTION. (CPC 402.5 & CRC R307) –REF. CALGREEN NOTES ON T SHTS. FOR MAX
FLOW RATE
FIREPLACE -FACTORY-BUILT DIRECT VENT GAS FIREPLACE W/. SEALED COMBUSTION
(CALGREEN 4.503) -FACTORY-BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR
COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING
AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. (CRC R1004.1)
A/C CONDENSER / HEAT PUMP -TO BE IN COMPLIANCE OF SECTION 307.3 OF CPC AS
SELECTED, VERIFY W/. OWNER -SIZE TBD, SEE T-24 ENERGY REPORT FOR MORE INFO –
PROVIDE POWER AND SOUND DAMPENING PAD AS REQ’D. –INSTALL AND MAINTAIN
REQUIRED CLEARANCES PER MFGR. INSTRUCTION
FAU -PROVIDE GAS S.O., POWER, AND VENTING AS REQ'D. BY MFG'R. –INSTALL PER
MFGR. INSTRUCTION
RECESSED MAIN SERVICE PANEL -400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE
OF PANEL TO ANY OBSTRUCTION) –GC TO COORDINATE W/. UTILITY COMPANY
ROOF/DECK DRAIN -PER CHAPTER 11 OF CPC -SIZE THE DRAIN AND PIPING PER TABLE
1103.1 AND 1103.2 OF CPC –ROOF DRAIN SHALL HAVE DOMED STRAINER (CPC 1102.2) –
REF. DETAIL 11/AD-1.0
OVERFLOW OR EMERGENCY DRAIN -PER CHAPTER 11 OF CPC -COPPER OR EQ., INSTALL
PER MFGR. INSTRUC., SLOPED TOWARD IN-WALL DRAIN INLETS –SLOPE AND SIZE PER
TABLE 1103.3 OF CPC –REF. DTL. 11/AD-1.0
2X4 STUD WALL
2X6 STUD WALL
2X8 STUD WALL
2X10 STUD WALL
EXT. POCKET DOOR WALL - TYP. 2X6 EXT. FRMG. AND 2X4 INTERIOR FRAMING W/.
DOUBLE TOP PLATE AND SINGLE SILL PLATE U.N.O., MIN. AIR SPACE/DOOR POCKET
TO BE VERIFIED W/. DOOR MFGR. - STUDS MIN. SPACING PER STRUCT. AND EXT.
FINISH MFGR. INSTRUCTION AND/OR LISTING –SEE EXT. WALL DETAILS AND STRUCT.
DWGS
CONCRETE WALL -12”REINFORCED CAST IN PLACE CONCRETE WALL TYP. U.N.O. PER
STRUCT., REF. STRCUTC. DWGS. –FOR BASEMENT/RETAINING CONCRETE WALL
PROVIDE WATERPROOFING OR DAMPPROOFING AND DRAINAGE AS REQUIRED PER
SECTION R406.1 & R406.2, REF. SOILS REPORT,WATERPROOFING & DAMPROOFING
NOTES ON SHEET T-1.1 –EXPOSED SURFACES TO HAVE TROWELED SMOOTH FINISH
WITH A LIGHT GRAY COLOR, PROVIDE SAMPLE FOR ARCH. APPROVAL
SLAB/FRAMING DEPRESSION -SEE STRUCT. DWGS. FOR THE RECESSION DETAILS -
FOR RECESSION SPECIFIC TO EQUIPMENT OR ASSEMBLY VERIFY THE REQUIRED
RECESSION W/. MFGR. OR FABRICATOR –SHOWER RECESSION TO BE VERIFIED W/.
I.D.
SEE SHEET AD-2.0 FOR THE TYPICAL DEPRESSION OF DOORS AND WINDOWS, VERIFY
ALL DEPRESSIONS W/. MFGR.
STUDS MIN. SPACING PER STRUCT. AND EXT. FINISH MFGR.
INSTRUCTION AND/OR LISTING –SEE EXT. WALL DETAILS AND
STRUCT. DWGS
VERTICAL STORM DRAIN PIPE IN-WALL / OVERFLOW -MTL. PIPE PER
CHAPTER 11 OF CPC, SIZE PER TABLE 1103.1 (MIN. 2”DIA. PIPE & TYP. 3”DIA. PIPE) –
SEE CIVIL DWGS. FOR TERMINATION DTLS. ABV. OR BLW. GROUND. VERIFY ALL
TERMINATION POINTS, TYPE AND DETAILS W/. CIVIL PRIOR TO POURING THE CONCRETE
SLAB
OVERFLOW
DRAINLINE
A-4.1
A-4.0
A-4.02
A-4.1
2
1
1
1
A-5.0
1
A-5.0
1
1
2
2
3 3
2
A-5.0
2
A-5.0
3' - 6 7/8"10' - 3 7/8"74' - 6"15' - 8 7/8"4' - 9"
19' - 9 1/4"37' - 3 3/4"17' - 5"5' - 9 1/2"
5' - 7 3/4"6' - 11 3/8"3' - 6 3/4"3' - 7 3/8"3' - 5 1/2"3' - 0"3' - 0"2' - 4 1/2"4' - 0 7/8"10' - 3 1/4"6' - 8 1/8"4' - 5 1/2"4' - 2 3/4"29' - 0 3/4"6' - 4 1/4"26' - 0 5/8"11' - 11 1/2"4' - 1 1/4"3' - 0"1' - 8"3' - 10"4' - 6"3' - 5 1/2"12' - 0"7 3/8"2' - 11 7/8"1' - 6 1/2"10' - 3 7/8"74' - 6"15' - 8 7/8"2' - 5 1/4"14' - 4"2' - 3 1/2"2' - 10 3/4"9' - 8 1/8"2' - 6 1/2"2' - 8 5/8"3' - 3 1/2"10' - 11 3/8"4' - 10 1/4"4' - 3"4' - 10 1/2"11' - 0"3' - 5 3/8"10' - 1 1/4"3' - 10 7/8"5' - 11 1/2"23' - 10 1/4"37' - 7 1/4"4' - 2 3/4"12' - 6"7' - 5"17' - 8 1/4"6' - 6 1/2"5' - 11 1/2"4' - 3"3' - 2"5' - 7 3/4"5' - 10 3/4"1' - 11 1/8"4' - 2 3/4"15' - 1 1/4"5' - 6"11' - 0"9' - 6 3/4"15' - 10 1/2"16' - 10 1/2"7"
2' - 6 5/8"4' - 4 1/4"4' - 7"1' - 10 1/4"4' - 5 1/2"1' - 9 1/2"10' - 6 1/2"5' - 1 5/8"2' - 0 5/8"7' - 0 7/8"11' - 2 1/8"
1' - 6"8' - 11 1/4"9' - 3 1/2"12' - 4 5/8"7' - 1 1/2"4' - 2 3/8"1' - 6 1/8"2' - 0"5' - 8 1/8"2' - 3"2' - 2 1/2"
5' - 7 3/4"6' - 11 3/8"7' - 2 1/8"3' - 4 3/4"3' - 7 7/8"3' - 4 3/4"1' - 10 1/8"6 3/8"3' - 0"11 1/4"14' - 8 1/2"6' - 1 3/4"11' - 11 1/2"1' - 10 1/4"2' - 9 1/8"11' - 9 1/2"8 3/8"12' - 0"4' - 1 1/4"2' - 4 1/4"4' - 3 1/2"1' - 10 1/4"4' - 6"4"4' - 11 3/8"4 5/8"6' - 2 5/8"
BEDROOM 2
W.I.C.HALL
BUNK ROOM
BATH 3
DEN
BATH 2
LAUNDRY MASTER CLOSET
MASTER BATHROOM
W.C.
MASTER BEDROOM
3" SLAB DEPRESSION FOR SHOWER -
VERIFY W/. G.C. & REF. STRUCT. DWGS.
SLAB DEPRESSION FOR
FIREPLACE -VERIFY W/. G.C. &
MFGR. & REF. STRUCT. DWGS.
SLAB DEPRESSION FOR DOOR
SYSTEM -VERIFY W/. G.C. &
MFGR. & REF. STRUCT. DWGS
3" SLAB DEPRESSION FOR SHOWER -
VERIFY W/. G.C. & REF. STRUCT. DWGS.
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
ANNOTATION LEGEND
GENERAL NOTESA
B
01.28.22
SECOND LEVEL
DIMENSION PLANMITCHELL RESIDENCETOM & KELLY MITCHELL
141 GALAXY DR.
NEWPORT BEACH, CA 92660
CDP FIRST CHECK
2631 WAVERLY DR.
NEWPORT BEACH, CA 92663
A-2.4
TBD
BRIAN JOWETT
NO. REVISION DATE
1/4" = 1'-0"1 SECOND LEVEL DIMENSION PLAN
PA2022-027
A-4.1
A-4.0
A-4.02
A-4.1
2
1
1
1
A-5.0
1
A-5.0
1
1
2
2
3 3
2
A-5.0
2
A-5.0
30' - 10 5/8"11' - 6 1/2"58' - 1 5/8"4' - 2 3/4"29' - 0 3/4"32' - 4 3/4"3' - 6 7/8"30' - 10 5/8"11' - 6 1/2"58' - 1 5/8"4' - 9"
2' - 8 1/4"3' - 0"3' - 0"2' - 10 1/4"
4' - 7 5/8"2' - 3 1/4"4' - 7 5/8"4' - 2 3/4"29' - 0 3/4"32' - 4 3/4"10' - 8 1/8"1' - 11 1/2"3' - 4 1/2"13' - 0 5/8"10' - 8 1/8"1' - 11 1/2"3' - 4 1/2"13' - 0 5/8"DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
ANNOTATION LEGEND
GENERAL NOTESA
B
01.28.22
ROOF DECK
DIMENSION PLANMITCHELL RESIDENCETOM & KELLY MITCHELL
141 GALAXY DR.
NEWPORT BEACH, CA 92660
CDP FIRST CHECK
2631 WAVERLY DR.
NEWPORT BEACH, CA 92663
A-2.5
TBD
BRIAN JOWETT
NO. REVISION DATE
1/4" = 1'-0"1 ROOF DECK DIMENSION PLAN
PA2022-027
DIMENSION NOTE:
ALL DIMS. ARE TO FACE OF STUD (F.O.S.) OR FACE OF SHT'G. (F.O.S.) TYP. U.N.O. EAVE DIMS. ARE FROM FACE OF SHT'G. TO FACE
OF FINISH FASCIA
ENLOSED ATTIC AND ENCLOSED RAFTER SPACES VENTING NOTES:
1. ENCLOSED ATTIC AND ENCLOSED RAFTER SPACES SHALL HAVE CROSS VENTILATION BY VENTILATION OPENING PROTECTED
AGAINST THE ENTRANCE OF RAIN OR SNOW UNLESS THEY MEET THE REQUIREMENT OF SECTION R806.5 FOR UNVENTED ATTIC
AND UNVENTED ENCLOSED RAFTER ASSEMBLIES. VENTILATION OPENING SHALL HAVE THE LEAST DIMENSION OF 1/16”MIN. AND
1/4”MAX OTHERWISE THE OPENING SHALL HAVE THE CORROSION-RESISTANT WIRE CLOTH SCREENING, HARDWARE CLOTH,
PERFORATED VINYL OR SIMILAR MATERIAL WITH OPENINGS HAVE A LEAST DIMENSION OF 1/16”MIN. AND 1/4”MAX. OPENING IN
ROOF FRAMING MEMBERS SHALL BE PER THE REQUIREMENT OF SECTION R802.7. REQUIRED VENTILATION OPENINGS SHALL
OPEN DIRECTLY TO THE OUTSIDE AIR AND SHALL BE PROTECTED TO PREVENT THE ENTRY OF BIRDS, RODENTS, SNAKES AND
OTHER SIMILAR CREATURES. (R806.1)
2. THE MINIMUM NET FREE VENTILATING AREA SHOULD BE 1/150 OF THE AREA OF THE VENTED SPACE, EXCEPT FOR THE PROJECT
LOCATED IN CLIMATE ZONE 14 OR 16 WITH A CLASS I OR II VAPOR RETARDER AT THE WARM-IN-WINTER SIDE OF THE CEILING
AND WHERE MIN. 40% AND MAX 50% OF THE REQUIRED VENTILATION PROVIDED IN THE UPPER PORTION OF THE ATTIC OR
RAFTER SPACE PER SECTION R806.2 THEN THE MINIMUM NET FREE VENTILATING AREA CAN BE 1/300 OF THE VENTED SPACE.
(R802.2)
3. PROVIDE 1”SPACE BETWEEN THE INSULATION AND THE ROOF SHEATHING WHERE EAVE OR CORNICE VENTS PROVIDE
BLOCKING, BRIDGING AND INSULATION SHALL NOT BLOCK THE FREE FLOW OF AIR. (R806.3)
4. INSTALL VENTILATOR PER MANUFACTURER INSTRUCTION. INSTALL VENTILATOR IN ROOF PER SECTION R903 AND VENTILATOR
IN WALL ASSEMBLIES PER SECTION R703.1.
5. FOR THE ATTIC WITH VERTICAL HEIGHT GREATER THAN OR EQUAL TO 30”(VERTICAL HEIGHT MEASURED FROM THE TOP OF
CEILING JOIST TO THE BOTTOM OF THE ROOF RAFTERS) WITHIN 30S.F. MIN. PROVIDE THE OPENING WITH ROUGH-FRAMED
OPENING OF NOT LESS THAN 22”X30”WHICH SHOULD BE LOCATED IN HALLWAY OR OTHER LOCATION WITH READY ACCESS. IF
THE ACCESS LOCATED IN THE WALL THEN THE WIDTH SHOULD BE 22”AND HEIGHT SHOULD BE 30”MIN. IF LOCATED IN CEILING
THEN THE MIN. UNOBSTRUCTED HEADROOM IN THE ATTIC SHOULD BE 30”FROM THE BOTTOM OF CEILING JOIST AT SOME POINT.
ROOF DRAINAGE:
IF THE PROJECT LOCATED IN THE AREA WITH EXPANSIVE OR COLLAPSIBLE SOILS, WATER RUNOFF FROM ROOFS OF ALL
DWELLINGS SHALL BE DISCHARGED TO THE GROUND SURFACE NOT LESS THAN 5 FEET FROM FOUNDATION WALLS OR TO AN
APPROVED DRAINAGE SYSTEM. (R801.3) -REF.CIVIL DWGS FOR STORM WATER MANAGMENT AND SYSTEM.
WEATHER PROTECTION:
1. ROOF DECKS SHALL BE COVERED WITH APPROVED ROOF COVERINGS SECURED TO THE BUILDING OR STRUCTURE IN
ACCORDANCE WITH THE CHAPTER 9 OF THE CURRENT CRC. ROOF ASSEMBLIES SHALL BE DESIGNED AND INSTALLED IN
ACCORDANCE WITH THE CHAPTER 9 OF CRC AND THE APPROVED MANUFACTURER’S INSTRUCTIONS SUCH THAT THE ROOF
ASSEMBLY SHALL SERVE TO PROTECT THE BUILDING OR STRUCTURE. (R903.1)
2. PROVIDE AND INSTALL FLASHING TO PREVENT ENTRY OF MOISTURE TO WALL AND ROOF ASSEMBLIES THRU THE JOINTS IN
COPINGS, PERMEABLE MATERIAL, AND AT INTERSECTION WITH PARAPET WALLS AND OTHER PENETRATION THRU ROOF. (R903.2)
3. FLASHINGS SHALL BE INSTALLED AT WALL AND ROOF INTERSECTIONS, WHEREVER THERE IS A CHANGE IN ROOF SLOPE OR
DIRECTION AND AROUND ROOF OPENINGS. A FLASHING SHALL BE INSTALLED TO DIVERT THE WATER AWAY FROM WHERE THE
EAVE OF A SLOPED ROOF INTERSECTS A VERTICAL SIDEWALL. WHERE FLASHING IS OF METAL, THE METAL SHALL BE CORROSION
RESISTANT WITH A THICKNESS OF NOT LESS THAN 0.019 INCH (0.5 MM) (NO. 26 GALVANIZED SHEET). (R903.2.1)
4. A CRICKET OR SADDLE SHALL BE INSTALLED ON THE RIDGE SIDE OF ANY CHIMNEY OR PENETRATION MORE THAN 30 INCHES
(762 MM) WIDE AS MEASURED PERPENDICULAR TO THE SLOPE. CRICKET OR SADDLE COVERINGS SHALL BE SHEET METAL OR OF
THE SAME MATERIAL AS THE ROOF COVERING. EXCEPT FOR UNIT SKYLIGHTS INSTALLED IN ACCORDANCE WITH HYPERLINK
"HTTPS://CODES.ICCSAFE.ORG/LOOKUP/CRC2019P1_PT03_CH03_SECR308.6" SECTION R308.6 AND FLASHED IN ACCORDANCE
WITH THE MANUFACTURER’S INSTRUCTIONS SHALL BE PERMITTED TO BE INSTALLED WITHOUT A CRICKET OR SADDLE. (R903.2)
5. PARAPET WALLS SHALL BE PROPERLY COPED WITH NONCOMBUSTIBLE, WEATHERPROOF MATERIALS OF A WIDTH NOT LESS
THAN THE THICKNESS OF THE PARAPET WALL. (R903.3)
6. UNLESS ROOFS ARE SLOPED TO DRAIN OVER ROOF EDGES, ROOF DRAINS SHALL BE INSTALLED AT EACH LOW POINT OF THE
ROOF. IF WATER CAN BE ENTRAPPED WITHIN THE ROOF AREA THEN SECONDARY EMERGENCY OVERFLOW ROOF DRAINS OR
SCUPPERS SHALL BE PROVIDED PER SECTION R903.4.1. (R903.4)
MISC. NOTES:
1. INSTALL ROOF PER ROOFING MFG'R. SPECS & INSTALLATION GUIDELINE
2. ARCH. TO APPV. SIZE, COLOR & PROFILE OF EAVE & RAKE COMPONENTS. G.C. TO PROVIDE MOCK-UPS.
3. UNVENTED ENCLOSED RAFTER ASSEMBLY: NO INTERIOR CLASS I VAPOR RETARDER SHALL BE INSTALLED ON THE CEILING SIDE
(ATTIC FLOOR) OF THE UNVENTED ATTIC ASSEMBLY OR ON THE CEILING SIDE OF THE UNVENTED ENCLOSED ROOF FRAMING
ASSEMBLY.
4. REF. WOOD OR WOODBASE PRODUCT NOTES ON FLOOR PLANS
1
A-5.0
1
A-5.0
1
1
2
2
3 3
F.Y.S.B.
10' - 0"S.Y.S.B.4' - 0"R.Y.S.B.
10' - 0"S.Y.S.B.4' - 0"3:123:127:127:127:127:12
7:12
7:12
7:12
7:12
7:12
7:12
7:12 7:12
46
3' - 0"5' - 0"1
1
2
3
1
4
1 2
5
6
7
8
8
9
9
9
10
10
10
10
30.65'
39.90'
37.66'
39.69'
42.47' HT. CERT. REQ'D.
32.16'
37.70'
11
ROOF DECK
2% SLOPE MIN
8"F.O.F.28' - 8 3/4"6 1/2"F.O.F.31' - 10 1/4"1 1/2"F.O.F.10' - 10"F.O.F.
7' - 5 5/8"5 1/2"
F.O.F.
8' - 3 7/8"6 1/4"
F.O.F.
10' - 1 7/8"2"
F.O.F.
9' - 4 7/8"6 1/4"
F.O.F.
11' - 3 3/8"6 1/2"
F.O.F.
10' - 1 7/8"2"
F.O.F.
9' - 4 7/8"6 1/4"2"F.O.F.4' - 0 3/4"8"F.O.F.3' - 6 3/4"F.O.F.3' - 6 3/4"8"3 1/2"
F.O.F.
15' - 5 3/8"
1' - 2"
F.O.F.
10' - 1 1/4"26' - 5 1/8"F.O.F.41' - 8 3/4"8"12
2
A-5.0
2
A-5.0
3:123:12
3.5:12
4.5:124:12F.O.F.
30' - 8 5/8"1 1/2"7' - 2 1/2"6' - 3 5/8"
6
20' - 11 1/4"13' - 0 3/4"7
10
1013
13
10
10
13
13
13
40.15'
38.38'40.14'
40.06'
42.23' HT. CERT. REQ'D.
32.18'3:127:127:127:12
7:12
7:127:12DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
GENERAL NOTESA
B KEYNOTES
BRANDON ARCHITECTS
01.28.22
ROOF PLANMITCHELL RESIDENCETOM & KELLY MITCHELL
141 GALAXY DR.
NEWPORT BEACH, CA 92660
CDP FIRST CHECK
2631 WAVERLY DR.
NEWPORT BEACH, CA 92663
A-3.0
TBD
BRIAN JOWETT
1 PROPERTY LINE
2 SIDE YARD SETBACK
3 FRONT YARD SETBACK
4 REAR YARD SETBACK
5 SKYLIGHT - SIZE AS DIM. - 'SKYCO' ICC #ESR-3837 OR EQUIV. (REF. DTLS.)
6 A/C. CONDENSER UNIT - SIZE TBD - PROVIDE POWER AND SOUND DAMPENING PAD AS REQ'D. (SOUND ATTENUATION REQ'D.
PER SECTION 10.26.045 N.B.M.C. UNDER SEPARATE PERMIT & PLAN CHECK)
7 FLAT COOL ROOF, CLASS 'A' - COLOR AS SELECTED - TPO MEMBRANE - REF. MAT. SCHEDULE SHT. A-4.0
8 GUTTER - ALUMINUM W/. KYNAR FINISH, SHAPE AS SEL. - PROVIDE SHOP DWGS. TO ARCH.
9 CHIMNEY CAP/SPARK ARRESTOR - AS SELECTED (NOTE: DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT THE
TERMINATION OF FACTORY BUILT CHIMNEYS EXCEPT WHERE SUCH SHROUDS ARE LISTED AND LABELED FOR USE WITH THE
SPECIFIC FAC. BLT. CHIMNEY SYSTEM AND ARE INSTALLED IN ACCORDANCE W/. MFGR. INST. INSTRUCTIONS. CMC 802.4.2.4)
10 WOOD SHINGLE ROOFING - REF. MAT. SCHEDULE SHT. A-4.0
11 OUTLINE OF STRUCTURE/WALLS BELOW
12 CHANNEL DRAIN - COPPER OR EQUIV., INSTALL PER MFGR. SPECS, SLOPED TO DRAINS & OVERFLOW DRAINS, REF. DTL. 6, 12 /
AD-1.0
13 STANDING SEAM METAL ROOFING - REF. MAT. SCHEDULE SHT. A-4.0
1/4" = 1'-0"1 ARCHITECTURAL ROOF PLAN
NO. REVISION DATE
PA2022-027
FIRST FLOOR F.F.
13.90'FIRST FLOOR F.F.
13.90'
SECOND FLOOR F.F.
25.11'
SECOND FLOOR F.F.
25.11'
ROOF PLATE
34.11'
ROOF PLATE
34.11'
SECOND FLOOR PLATE
23.90'
SECOND FLOOR PLATE
23.90'
MAX. RIDGE HT.
42.68'
MAX. RIDGE HT.
42.68'
GRADE PLANE
13.68'
GRADE PLANE
13.68'
1
2
MAX. FLAT ROOF
37.68'
MAX. FLAT ROOF
37.68'
ROOF DECK F.F.
34.25'
ROOF DECK F.F.
34.25'
ROOF DECK PLATE
33.26'
ROOF DECK PLATE
33.26'
16 15 1417
18 35
13
20
4
21 19 3436
1229' - 0"24' - 0"11' - 2 1/2"9' - 0"10' - 0"1' - 2 1/2"9' - 0"29' - 0"24' - 0"11' - 2 1/2"9' - 0"10' - 0"1' - 2 1/2"9' - 0"SILL HT.3' - 0"HD. HT.9' - 0"SILL HT.6' - 8 1/2"HD. HT.14' - 8 1/2"SILL HT.3' - 0"HD. HT.8' - 0"42.47' HT. CERT. REQ'D.
39.69'
39.90'
7:12
29.23'ABV. F.F.42" MIN.4
4
2
2
85
4
SECOND FLOOR T.O.S.
24.98'
SECOND FLOOR T.O.S.
24.98'10' - 0"1' - 1"1 1/2"9' - 0"10' - 0"1' - 1"1 1/2"9' - 0"38.63'
40.14'
42.23' HT. CERT. REQ'D.
13
8
61 62 63
2 2
15
WINDOWS & DOORS:
AUTHORIZED DEALER (PRODUCTS LISTED BELOW)
SUPPLIER:ASSOCIATED BUILDING SUPPLY
ADDRESS:STONE MILL DESIGN CENTER 2915 RED HILL AVE., SUITE F104, COSTA MESA, CA 92626
CONTACT:JOE YOUNAN
PHONE:949-872-3319
FAX:206-666-2150
EMAIL:JYOUNAN@ABSSOCAL.COM
WEB:WWW.ASSOCIATEDBUILDINGSUPPLY.COM
ALUMINUM CLAD WINDOWS & PATIO DOORS
MANUFACTURER: JELD-WEN WINDOWS & DOORS
PRODUCT:CUSTOM COLLECTION
ADDRESS:3250 LAKEPORT BLVD. P.O. BOX 1329; KLAMATH FALLS, OREGON 97601
PHONE:541-885-7412 OR 800-535-3936
FAX:541-884-3331
WEB:WWW.JELD-WEN.COM
MULTI SLIDE DOORS & STOREFRONT
MANUFACTURER:WESTERN WINDOW SYSTEMS
PRODUCT: SERIES 600 & STOREFRONT SYSTEMS
ADDRESS: 5621 S. 25TH ST., PHOENIX, AZ 85040
PHONE: 877.268.1300
WEB: WWW.WESTERNWINDOWSYSTEMS.COM
WOOD SIDING:
MANUFACTURER: JAMES HARDIE BUILDING PRODUCTS, INC.
ADDRESS:10901 ELM AVENUE, FONTANA, CA 92337
PHONE:909.356.6366
COLOR:WHITE -TBD
APPLICATION:V-GROOVE SHIPLAP
CODE:ICC# ESR-290
BRICK VENEER:
PRODUCT:RECLAIMED BRICK SAWN VENEER
COLOR:LIME (WHITE) WASHED OR STUCCO FOG
THICKNESS:1" -1.5" NOMINAL
WEIGHT:<8.5 LBS / S.F.
APPLICATION:MODULAR BRICK COURSE PER ELEVATION
DETAIL REF.:8/AD-1.0
APPROVALS:N/A
ROOFING:
PRODUCT: STANDING SEAM METAL ROOFING, ULTRA-COOL, CB-150
MFGR:CUSTOM-BILT METALS
COLOR: TO BE APPROVED BY ARCH. & OWNER
CODE:ICC # ESR-2048, CLASS "A" ASSEMBLE
WEIGHT: APPX. 2 LBS./S.F.
WOOD SHINGLE ROOFING:
PRODUCT:#1 WESTERN RED CEDAR, WOOD SHINGLE -FIRE TREATED
MFGR:FSR TREATMENT, INC. WWW.FIRESMARTROOFING.COM (OR EQUIV.)
COLOR:NATURAL
APPLICATION:18" RE-BUTTED & RE-JOINED PERFECTION SHINGLES (100% EDGE GRAIN, 100% CLEAR) 5 1/2" EXPOSURE.
CLOSED VALLEY W/. MITERED HIP CUTS, 16' GUARGE COPPER FLASHING, STAGGERED COURSING (REF. DTL.
1/A-5)
CODE:CLASS A ASSEMBLY (ICC #ESR-1410)
GUTTERS:
MATERIAL: METAL -COPPER/ALUM. PAINTED KYNAR
SHAPE: HALF ROUND/SQUARE (5") (VERIFY W/. ARCH.)
GARAGE DOORS:
SUPPLIER:RANCH HOUSE DOORS
WEB:WWW.RANCHHOUSEDOORS.COM
STYLE: CUSTOM
MATERIAL: CUSTOM BUILT, WOOD & GLASS
WATERPROOF DECK MEMBRANE:
MFGR:WESTCOAT
ADDRESS:770 GATEWAY CENTER DRIVE, SAN DIEGO, CA 92102
PRODUCT:AXL CUSTOM
PHONE: 800.250.4519
WEB:WWW.WESTCOAT.COM
CODE:ICC # ESR-2201
FASCIA, TRIM & PANELING:
MANUFACTURER:AZEK EXTERIORS
COLOR:PAINTED WHITE (VERIFY W/. OWNER)
APPLICATION:ARCH. TO APPV. PROFILES
FLASHING & WEATHERSTRIPPING
PROVIDE MIN. 24 GUAGE METAL (16 OZ.) SHEETING (TO MATCH) FOR ALL EXTERIOR FLASHING & WEATHERSTRIPPING
APPLICATIONS. VERIFY W/. ARCHITECT ANY UNCONVENTIONAL ENVELOPE WATERPROOFING AREAS PRIOR TO INSTALLATION.
1. FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT LABELS.
2. REF. ROOF PLAN (A-3) FOR ALL PLATE HTS. & RIDGE HTS.
FIRST FLOOR F.F.
13.90'
FIRST FLOOR F.F.
13.90'
SECOND FLOOR F.F.
25.11'SECOND FLOOR F.F.
25.11'
ROOF PLATE
34.11'
ROOF PLATE
34.11'
SECOND FLOOR PLATE
23.90'
SECOND FLOOR PLATE
23.90'
MAX. RIDGE HT.
42.68'
MAX. RIDGE HT.
42.68'
GRADE PLANE
13.68'
GRADE PLANE
13.68'29' - 0"3
9' - 0"1' - 2 1/2"10' - 0"MAX. FLAT ROOF
37.68'
MAX. FLAT ROOF
37.68'24' - 0"ROOF DECK F.F.
34.25'
ROOF DECK F.F.
34.25'
ROOF DECK PLATE
33.26'ROOF DECK PLATE
33.26'
29 28
9
37
1129' - 0"24' - 0"9' - 0"11' - 2 1/2"9' - 0"1' - 2 1/2"10' - 0"9' - 0"11' - 2 1/2"HD. HT.9' - 0"SILL HT.3' - 7"HD. HT.6' - 1"32.16'
3 :12
30.65'
28.77' T.R.ABV. F.F.42" MIN.1
2
3
2 4
4
5
6
7
PL
9 9
9
10
11
SECOND FLOOR T.O.S.
24.98'
SECOND FLOOR T.O.S.
24.98'
2
A-5.0
4
4
2
4
48 47
3 2 3 1 2
3:1 2
3:12
7:127:1 2
8
12
5
1314
3
13
42.23' HT. CERT. REQ'D.42.47' HT. CERT. REQ'D.
40.15'40.14'
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
MATERIAL SPECIFICATIONSA
KEYNOTESC
GENERAL NOTESB
BRANDON ARCHITECTS
01.28.22
EXTERIOR
ELEVATIONSMITCHELL RESIDENCETOM & KELLY MITCHELL
141 GALAXY DR.
NEWPORT BEACH, CA 92660
CDP FIRST CHECK
2631 WAVERLY DR.
NEWPORT BEACH, CA 92663
A-4.0
TBD
BRIAN JOWETT
1/4" = 1'-0"1 EAST ELEVATION
1 T&G PANELING, REVEAL AS SEL. FINISH AS SELECTED - REF. MATERIAL SCHEDULE SHT. A-4.0
2 WOOD SHINGLE ROOFING - REF. MAT. SCHEDULE SHT. A-4.0
3 STANDING SEAM METAL ROOFING - REF. MAT. SCHEDULE SHT. A-4.0
4 BRICK VENEER - REF. MAT. SCHEDULE SHT. A-4.0
5 DOWNSPOUT - ALUMINUM W/. KYNAR FINISH OR EQUIV. - AS SEL. (ARCH. TO APPROVE)
6 GUTTER - ALUMINUM W/. KYNAR FINISH, SHAPE AS SEL. - PROVIDE SHOP DWGS. TO ARCH.
7 EXTERIOR GUARDRAIL - MIN. 42" HEIGHT - 4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
8 DECO. 'BELLYBAND' - EXT. PAINT GRADE, SMOOTH FINISH, ARCH. TO APPROVE PROFILE
9 CHIMNEY CAP/SPARK ARRESTOR - AS SELECTED (NOTE: DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT THE
TERMINATION OF FACTORY BUILT CHIMNEYS EXCEPT WHERE SUCH SHROUDS ARE LISTED AND LABELED FOR USE WITH THE
SPECIFIC FAC. BLT. CHIMNEY SYSTEM AND ARE INSTALLED IN ACCORDANCE W/. MFGR. INST. INSTRUCTIONS. CMC 802.4.2.4)
10 6X10 DECO. TIMBER - CHAMFER EDGES APPX. 1/2", PAINT AS SEL.
11 4X6 DECO. TIMBER RAFTER - SHAPED TAIL AS OCCURS (ARCH. TO APPV. PROFILE), SEALED, PAINT AS SEL.
12 4X6 DECO. TIMBER CORBEL - CHAMFER EDGES APPX. 1/2", PAINT AS SEL.
13 SHIP LAP SIDING, FINISH AS SELECTED - REF. MATERIAL SCHEDULE SHT. A-4.0
14 SKYLIGHT - SIZE AS DIM. - 'SKYCO' ICC #ESR-3837 OR EQUIV. (REF. DTLS.)
15 RECESSED MAIN SERVICE PANEL, 400 AMP MAX. (MAINTAIN 36"" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION)
NO. REVISION DATE
1/4" = 1'-0"2 SOUTH ELEVATION
PA2022-027
WINDOWS & DOORS:
AUTHORIZED DEALER (PRODUCTS LISTED BELOW)
SUPPLIER:ASSOCIATED BUILDING SUPPLY
ADDRESS:STONE MILL DESIGN CENTER 2915 RED HILL AVE., SUITE F104, COSTA MESA, CA 92626
CONTACT:JOE YOUNAN
PHONE:949-872-3319
FAX:206-666-2150
EMAIL:JYOUNAN@ABSSOCAL.COM
WEB:WWW.ASSOCIATEDBUILDINGSUPPLY.COM
ALUMINUM CLAD WINDOWS & PATIO DOORS
MANUFACTURER: JELD-WEN WINDOWS & DOORS
PRODUCT:CUSTOM COLLECTION
ADDRESS:3250 LAKEPORT BLVD. P.O. BOX 1329; KLAMATH FALLS, OREGON 97601
PHONE:541-885-7412 OR 800-535-3936
FAX:541-884-3331
WEB:WWW.JELD-WEN.COM
MULTI SLIDE DOORS & STOREFRONT
MANUFACTURER:WESTERN WINDOW SYSTEMS
PRODUCT: SERIES 600 & STOREFRONT SYSTEMS
ADDRESS: 5621 S. 25TH ST., PHOENIX, AZ 85040
PHONE: 877.268.1300
WEB: WWW.WESTERNWINDOWSYSTEMS.COM
WOOD SIDING:
MANUFACTURER: JAMES HARDIE BUILDING PRODUCTS, INC.
ADDRESS:10901 ELM AVENUE, FONTANA, CA 92337
PHONE:909.356.6366
COLOR:WHITE -TBD
APPLICATION:V-GROOVE SHIPLAP
CODE:ICC# ESR-290
BRICK VENEER:
PRODUCT:RECLAIMED BRICK SAWN VENEER
COLOR:LIME (WHITE) WASHED OR STUCCO FOG
THICKNESS:1" -1.5" NOMINAL
WEIGHT:<8.5 LBS / S.F.
APPLICATION:MODULAR BRICK COURSE PER ELEVATION
DETAIL REF.:8/AD-1.0
APPROVALS:N/A
ROOFING:
PRODUCT: STANDING SEAM METAL ROOFING, ULTRA-COOL, CB-150
MFGR:CUSTOM-BILT METALS
COLOR: TO BE APPROVED BY ARCH. & OWNER
CODE:ICC # ESR-2048, CLASS "A" ASSEMBLE
WEIGHT: APPX. 2 LBS./S.F.
WOOD SHINGLE ROOFING:
PRODUCT:#1 WESTERN RED CEDAR, WOOD SHINGLE -FIRE TREATED
MFGR:FSR TREATMENT, INC. WWW.FIRESMARTROOFING.COM (OR EQUIV.)
COLOR:NATURAL
APPLICATION:18" RE-BUTTED & RE-JOINED PERFECTION SHINGLES (100% EDGE GRAIN, 100% CLEAR) 5 1/2" EXPOSURE.
CLOSED VALLEY W/. MITERED HIP CUTS, 16' GUARGE COPPER FLASHING, STAGGERED COURSING (REF. DTL.
1/A-5)
CODE:CLASS A ASSEMBLY (ICC #ESR-1410)
GUTTERS:
MATERIAL: METAL -COPPER/ALUM. PAINTED KYNAR
SHAPE: HALF ROUND/SQUARE (5") (VERIFY W/. ARCH.)
GARAGE DOORS:
SUPPLIER:RANCH HOUSE DOORS
WEB:WWW.RANCHHOUSEDOORS.COM
STYLE: CUSTOM
MATERIAL: CUSTOM BUILT, WOOD & GLASS
WATERPROOF DECK MEMBRANE:
MFGR:WESTCOAT
ADDRESS:770 GATEWAY CENTER DRIVE, SAN DIEGO, CA 92102
PRODUCT:AXL CUSTOM
PHONE: 800.250.4519
WEB:WWW.WESTCOAT.COM
CODE:ICC # ESR-2201
FASCIA, TRIM & PANELING:
MANUFACTURER:AZEK EXTERIORS
COLOR:PAINTED WHITE (VERIFY W/. OWNER)
APPLICATION:ARCH. TO APPV. PROFILES
FLASHING & WEATHERSTRIPPING
PROVIDE MIN. 24 GUAGE METAL (16 OZ.) SHEETING (TO MATCH) FOR ALL EXTERIOR FLASHING & WEATHERSTRIPPING
APPLICATIONS. VERIFY W/. ARCHITECT ANY UNCONVENTIONAL ENVELOPE WATERPROOFING AREAS PRIOR TO INSTALLATION.
1. FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT LABELS.
2. REF. ROOF PLAN (A-3) FOR ALL PLATE HTS. & RIDGE HTS.
FIRST FLOOR F.F.
13.90'FIRST FLOOR F.F.
13.90'
SECOND FLOOR F.F.
25.11'
SECOND FLOOR F.F.
25.11'
ROOF PLATE
34.11'
ROOF PLATE
34.11'
SECOND FLOOR PLATE
23.90'
SECOND FLOOR PLATE
23.90'
MAX. RIDGE HT.
42.68'
MAX. RIDGE HT.
42.68'
GRADE PLANE
13.68'
GRADE PLANE
13.68'
3
MAX. FLAT ROOF
37.68'
MAX. FLAT ROOF
37.68'
ROOF DECK F.F.
34.25'
ROOF DECK F.F.
34.25'
ROOF DECK PLATE
33.26'
ROOF DECK PLATE
33.26'
11 10
33
12
32
31
10 91129' - 0"24' - 0"9' - 0"1' - 2 1/2"10' - 0"9' - 0"11' - 2 1/2"24' - 0"29' - 0"9' - 0"11' - 2 1/2"9' - 0"1' - 2 1/2"10' - 0"SILL HT.3' - 0"HD. HT.8' - 0"SILL HT.5' - 0"30.65'
1
2
2
3
3
4
5
6
PL
10
SECOND FLOOR T.O.S.
24.98'
SECOND FLOOR T.O.S.
24.98'
2
A-5.0
66
9
11
7 :1 2 7:12
7 :1 2
7:12
3 :12 3:12
38.38'
39.75'
42.23' HT. CERT. REQ'D.
FIRST FLOOR F.F.
13.90'
FIRST FLOOR F.F.
13.90'
SECOND FLOOR F.F.
25.11'
SECOND FLOOR F.F.
25.11'
ROOF PLATE
34.11'
ROOF PLATE
34.11'
SECOND FLOOR PLATE
23.90'
SECOND FLOOR PLATE
23.90'
MAX. RIDGE HT.
42.68'
MAX. RIDGE HT.
42.68'
GRADE PLANE
13.68'
GRADE PLANE
13.68'
1 2
MAX. FLAT ROOF
37.68'
MAX. FLAT ROOF
37.68'
ROOF DECK F.F.
34.25'ROOF DECK F.F.
34.25'
ROOF DECK PLATE
33.26'
ROOF DECK PLATE
33.26'
78
2425
6
27 2628
46
30
8 629' - 0"24' - 0"9' - 0"11' - 2 1/2"9' - 0"1' - 2 1/2"10' - 0"29' - 0"24' - 0"9' - 0"11' - 2 1/2"9' - 0"1' - 2 1/2"10' - 0"SILL HT.3' - 0"SILL HT.3' - 0"HD. HT.11' - 0"SILL HT.3' - 0"7 :1 2 7:12
ABV. F.F.42" MIN.29.23'
42.47' HT. CERT. REQ'D.
37.70'
39.69'
37.66'
39.90'40.15'
6
3
2
3
6
6
6
2
4
5
78
9
9
9
SECOND FLOOR T.O.S.
24.98'
SECOND FLOOR T.O.S.
24.98'
38.91'
42.23' HT. CERT. REQ'D.
3.5:12
3:12
7 :1 2
7:12
7 :1 2 7:12
11
2
122
5 4
HD. HT.9' - 0"13
14
SILL HT.3' - 0"HD. HT.9' - 0"DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
MATERIAL SPECIFICATIONSA
KEYNOTESC
GENERAL NOTESB
BRANDON ARCHITECTS
01.28.22
EXTERIOR
ELEVATIONSMITCHELL RESIDENCETOM & KELLY MITCHELL
141 GALAXY DR.
NEWPORT BEACH, CA 92660
CDP FIRST CHECK
2631 WAVERLY DR.
NEWPORT BEACH, CA 92663
A-4.1
TBD
BRIAN JOWETT
1 T&G PANELING, REVEAL AS SEL. FINISH AS SELECTED - REF. MATERIAL SCHEDULE SHT. A-4.0
2 WOOD SHINGLE ROOFING - REF. MAT. SCHEDULE SHT. A-4.0
3 SHIP LAP SIDING, FINISH AS SELECTED - REF. MATERIAL SCHEDULE SHT. A-4.0
4 DOWNSPOUT - ALUMINUM W/. KYNAR FINISH OR EQUIV. - AS SEL. (ARCH. TO APPROVE)
5 GUTTER - ALUMINUM W/. KYNAR FINISH, SHAPE AS SEL. - PROVIDE SHOP DWGS. TO ARCH.
6 BRICK VENEER - REF. MAT. SCHEDULE SHT. A-4.0
7 EXTERIOR FIREPLACE - GAS ONLY APPLIANCE
8 BUILT-IN BBQ ISLAND, MAX. HT. 60" - REF. LAND. DWGS.
9 CHIMNEY CAP/SPARK ARRESTOR - AS SELECTED (NOTE: DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT THE
TERMINATION OF FACTORY BUILT CHIMNEYS EXCEPT WHERE SUCH SHROUDS ARE LISTED AND LABELED FOR USE WITH THE
SPECIFIC FAC. BLT. CHIMNEY SYSTEM AND ARE INSTALLED IN ACCORDANCE W/. MFGR. INST. INSTRUCTIONS. CMC 802.4.2.4)
10 BELOW-WINDOW PLANTER BOXES
11 CHIMNEY SHALL EXTEND AT LEAST 2' HIGHER THAN ANY PORTION OF THE BUILDING W/IN. 10', BUT SHALL NOT BE LESS THAN
3' ABV. THE HIGHEST POINT WHERE THE CHIMNEY PASSES THRU THE ROOF (CBC 2113.9)
12 SKYLIGHT - SIZE AS DIM. - 'SKYCO' ICC #ESR-3837 OR EQUIV. (REF. DTLS.)
13 EXPOSED STEEL BEAM SIZE PER STRUCT. DWGS., PAINT AND SEAL AS REQ'D. - COORDINATE W/. INTERIOR.
14 STANDING SEAM METAL ROOFING - REF. MAT. SCHEDULE SHT. A-4.0
NO. REVISION DATE
1/4" = 1'-0"1 NORTH ELEVATION
1/4" = 1'-0"2 WEST ELEVATION
PA2022-027
FIRST FLOOR F.F.
13.90'
FIRST FLOOR F.F.
13.90'
SECOND FLOOR F.F.
25.11'
SECOND FLOOR F.F.
25.11'
ROOF PLATE
34.11'
ROOF PLATE
34.11'
SECOND FLOOR PLATE
23.90'
SECOND FLOOR PLATE
23.90'CLR.8' - 1 1/4"1' - 2 1/2"10' - 0"9' - 0"ROOF DECK F.F.
34.25'
ROOF DECK F.F.
34.25'
ROOF DECK PLATE
33.26'
ROOF DECK PLATE
33.26'
SECOND FLOOR T.O.S.
24.98'
SECOND FLOOR T.O.S.
24.98'
2
A-5.0
3:1 2 3:12
3:12
7:12
9
7
14
22
37
46
29
KITCHEN
MASTER CLOSET
MASTER BEDROOMMASTER BATHROOM
ROOF DECK
CLR.8' - 1 1/4"CLR.8' - 1 1/4"CLR.9' - 11 3/8"42.23'
40.15'
30.65'
1
2
3
4
5
3
5
6
7
8
9 10
9' - 0"1 1/2"1' - 1"10' - 0"EXTERIOR WALL:
2 x 4 CONST.:R-13 MIN.
2 x 6 CONST. OR LARGER:R-20 MIN.
RAISED FLOOR:R-30 MIN.
ROOF:R-30
NOTES:
1. REF. T-24 REPORT FOR MORE INFORMATION
2. PROVIDE BID FOR INSULATION OF ENTIRE HOME
*TOTAL R-VALUE INCLUDING THE RIDGID AND SPRAYED AIR-IMPERMEABLE INSULATION WHERE OCCURS FOR UNVENTED ASSEMBLY
**ALWAYS CHECK THIS INSULATION SCHEDULE FOR CONFORMANCE WITH THE TITLE 24 REPORT**
FIREBLOCKING AND DRAFTSTOPPING SHALL BE INSTALLED TO CUT OFF ALL CONCEALED DRAFT OPENINGS (BOTH VERTICAL AND
HORIZONTAL) AND SHALL FORM AN EFFECTIVE BARRIER BETWEEN FLOORS, BETWEEN A TOP STORY AND A ROOF OR ATTIC SPACE,
AND SHALL SUBDIVIDE ATTIC SPACES, CONCEALED ROOF SPACES AND FLOOR-CEILING ASSEMBLIES. THE INTEGRITY OF ALL FIRE
BLOCKS AND DRAFT STOPS SHALL BE MAINTAINED.
FIRE BLOCKS
FIREBLOCKING SHALL BE PROVIDED IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES, AT
THE CEILING AND FLOOR LEVELS AND AT 10-FOOT INTERVALS BOTH VERTICAL AND HORIZONTAL.
FIRE BLOCK CONSTRUCTION
FIREBLOCKING SHALL CONSIST OF 2 INCHES NOMINAL LUMBER. FIRE BLOCKS MAY ALSO BE OF GYPSUM BOARD, CEMENT FIBER
BOARD, BATTS OR BLANKETS OF MINERAL OR GLASS FIBER, OR OTHER APPROVED MATERIALS INSTALLED IN SUCH A MANNER AS
TO BE SECURELY RETAINED IN PLACE. LOOSE-FILL INSULATION MATERIAL SHALL NOT BE USED.
WALLS HAVING PARALLEL OR STAGGERED STUDS FOR SOUND-TRANSMISSION CONTROL SHALL HAVE FIRE BLOCKS OF BATTS OR
BLANKETS OF MINERAL OR GLASS FIBER OR OTHER APPROVED FLEXIBLE MATERIALS.
DRAFT STOPS
DRAFTSTOPPING SHALL BE PROVIDED IN THE LOCATIONS SET FORTH IN THIS SECTION.
FLOOR-CEILING ASSEMBLIES
DRAFT STOPS SHALL BE INSTALLED IN FLOOR-CEILING ASSEMBLIES OF THE BUILDING. SUCH DRAFT STOPS SHALL BE IN LINE WITH
WALLS SEPARATING INDIVIDUAL DWELLING UNITS FROM EACH OTHER AND FROM OTHER AREAS.
ATTICS
DRAFT STOPS SHALL BE INSTALLED IN THE ATTICS, MANSARDS, OVERHANGS, FALSE FRONTS SET OUT FROM WALLS AND SIMILAR
CONCEALED SPACES OF THIS BUILDING. SUCH DRAFT STOPS SHALL BE ABOVE AND IN LINE WITH THE WALLS SEPARATING
INDIVIDUAL DWELLING UNITS FROM EACH OTHER AND FROM OTHER USES.
DRAFT STOP CONSTRUCTION
DRAFTSTOPPING MATERIALS SHALL NOT BE LESS THAN ½-INCH GYPSUM BOARD, 3/8-INCH WOOD STRUCTURAL PANEL, 3/8-INCH
TYPE 2-M PARTICLEBOARD OR OTHER APPROVED MATERIALS ADEQUATELY SUPPORTED.
OPENINGS IN THE PARTITIONS SHALL BE PROTECTED BY SELF-CLOSING DOORS WITH AUTOMATIC LATCHES CONSTRUCTED AS
REQUIRED FOR THE PARTITIONS.
ROOM TAGROOM NAME
1
A-5.0
1 1
?
1
1
ELEVATION / SECTION INDICATOR
AD-1.0
1 CALL-OUT TAG
10.00'
SPOT ELEVATION
KEYNOTE TAG
REVISION TAG
DOOR / WINDOW / WINDOW WALL TAG
FIRE RATED CEILING ASS'Y -REF. DTLS. 7/AD-1.0
1-HR RATED INT CONDITION -REF. DTLS. 7/AD-1.0
1-HR RATED EXT CONDITION -REF. DTLS. 7/AD-1.0
CONCRETE WALL/PODIUM DECK -PER STRUCT. REF. STRUCT DWGS. –FOR SLAB ON
GRADE PROVIDE BASE PER R506.2.2 AND VAPOR RETARDER PER R506.2.3 W/.
CAPILLARY BREAK
INSULATED BUILDING ENVELOPE -2X STUDS PER PLANS, SEE DIMENSION PLANS FOR
MORE INFO –INSULATION PER INSULATION SCHEDULE AND T-24 ENERGY REPORTS
UNVENTED ROOF ASSEMBLY ROOF FRAMING -PER STRUCT., REF. STRUCT.
DWGS. –UNVENTED ASSEMBLY TO COMPLY W/. SECTION R806.5 OF CRC, AIR-
IMPERMEABLE VALUE PER TABLE R806.5 OF CRC
VENTED ROOF ASSEMBLY ROOF FRAMING -PER STRUCT., REF. STRUCT. DWGS. –
PROVIDE CROSS VENTILATION PER SECTION R806 OF CRC, SEE ROOF PLAN SHEET A-3.0
FOR ATTIC VENT CALC AND MORE INFO
FIRST FLOOR F.F.
13.90'
FIRST FLOOR F.F.
13.90'
SECOND FLOOR F.F.
25.11'
SECOND FLOOR F.F.
25.11'
ROOF PLATE
34.11'
ROOF PLATE
34.11'
SECOND FLOOR PLATE
23.90'
SECOND FLOOR PLATE
23.90'
1
A-5.0
ROOF DECK F.F.
34.25'
ROOF DECK F.F.
34.25'
ROOF DECK PLATE
33.26'
ROOF DECK PLATE
33.26'
SECOND FLOOR T.O.S.
24.98'
SECOND FLOOR T.O.S.
24.98'
HALLWAYKITCHENFOYER
MASTER BEDROOM DEN HALL W.I.C.
ROOF DECK STAIRS LANDING
6 8
6
33
282726
2425
4 3-CAR GARAGE
10
8
9
11
12
13
7
14
14
5
15 ABV. F.F.42" MINABV. F.F.42" MIN.3 .5 :1 2
7:12
39.90'
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
FIRE-BLOCKING & DRAFT STOP NOTESA
INSULATION SCHEDULEB
ANNOTATION LEGENDC
KEYNOTESD
BRANDON ARCHITECTS
01.28.22
BUILDING SECTIONSMITCHELL RESIDENCETOM & KELLY MITCHELL
141 GALAXY DR.
NEWPORT BEACH, CA 92660
CDP FIRST CHECK
2631 WAVERLY DR.
NEWPORT BEACH, CA 92663
A-5.0
TBD
BRIAN JOWETT
1/4" = 1'-0"1 TRANSVERSE SECTION 1
1 WOOD SHINGLE ROOFING - REF. MAT. SCHEDULE SHT. A-4.0
2 T&G PANELING, REVEAL AS SEL. FINISH AS SELECTED - REF. MATERIAL SCHEDULE SHT. A-4.0
3 BRICK VENEER - REF. MAT. SCHEDULE SHT. A-4.0
4 CHIMNEY CAP/SPARK ARRESTOR - AS SELECTED (NOTE: DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT THE
TERMINATION OF FACTORY BUILT CHIMNEYS EXCEPT WHERE SUCH SHROUDS ARE LISTED AND LABELED FOR USE WITH THE
SPECIFIC FAC. BLT. CHIMNEY SYSTEM AND ARE INSTALLED IN ACCORDANCE W/. MFGR. INST. INSTRUCTIONS. CMC 802.4.2.4)
5 SHIP LAP SIDING, FINISH AS SELECTED - REF. MATERIAL SCHEDULE SHT. A-4.0
6 SKYLIGHT - SIZE AS DIM. - 'SKYCO' ICC #ESR-3837 OR EQUIV. (REF. DTLS.)
7 MAT SLAB - REF. STRUCT.
8 FLOOR JOISTS - REF. STRUCT.
9 CEILING FRAMING - REF. STRUCT.
10 ROOF RAFTERS - REF. STRUCT.
11 INTERIOR GUARDRAIL - MIN. 42" HIGH - MATERIAL AS SELECTED, <4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
12 A/C. CONDENSER UNIT - SIZE TBD - PROVIDE POWER AND SOUND DAMPENING PAD AS REQ'D. (SOUND ATTENUATION REQ'D.
PER SECTION 10.26.045 N.B.M.C. UNDER SEPARATE PERMIT & PLAN CHECK)
13 FAU - PROVIDE GAS S.O., POWER, AND VENTING AS REQ'D. BY MFG'R.
14 FIREPLACE - PREFABRICATED, GAS ONLY, 'DAVINCI - ISLAND' - ANSI Z21.50B-2014 [DTL. 22/AD-1] (FACTORY BUILT
FIREPLACES, CHIMNEYS, AND ALL OF THEIR COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE W/. THEIR
LISTING AND MFG'R. INSTALLATION INSTRUCTIONS. GASEOUS FUEL BURNING PAN MUST BE PERMANENTLY ANCHORED TO
THE FIREBOX. FIREPLACE MUST COMPLY W/. THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES.)
15 EXTERIOR GUARDRAIL - MIN. 42" HEIGHT - 4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
NO. REVISION DATE
1/4" = 1'-0"2 LONGITUDINAL SECTION 1
PA2022-027