HomeMy WebLinkAboutPA2022-044_20220217_Plans_24x36n
E. BALBOA BLVD.
THESE DRAWINGS AND
SPECIFICATIONS, IDEAS, DESIGNS AND
ARRANGEMENTS ARE, AND SHALL
REMAIN, THE PROPERTY OF C.B. HOME
DESIGN. NO PART SHALL BE COPIED,
REPRODUCED OR OTHERWISE USED,
DIRECTLY OR INDIRECTLY, IN WHOLE
OR IN PART, IN CONNECTION WITH ANY
OTHER WORK OR PROJECT WITHOUT
THE WRITTEN CONSENT OF C.B. HOME
DESIGN. VISUAL CONTACT WITH THESE
DRAWINGS AND/OR SPECIFICATIONS
SHALL CONSTITUTE A PRIMA FACIE
EVIDENCE OF ACCEPTANCE OF THESE
RESTRICTIONS.
1168 SAN GABRIEL BLVD
SUITE P
ROSEMEAD, CA 91770
PHONE 626 279-67
ePailcbhoPe626#JPail.coP
PROJECT ADDRESS:sheet no:
T-1
sheet title:OWNER INFO:site plan
revisions:
-
-
-
drawn by:
job number:
1/8" = 1'-0"
GC/JC/OP
scope of work
sheet index
vicinity map
tabulations
abbreviations
general notes administrative req's
consultants
607 E. Balboa Blvd.Newport Beach, CA.92661scale :
CB20-212
C.B. HOME
D E S I G N
DENTAL & SPA
607 E. Balboa Blvd.
Newport Beach, CA.92661
DR. XERXEZ CALILUNGRAKEL APODACASAMUEL HERNANDEZPA2022-044
THESE DRAWINGS AND
SPECIFICATIONS, IDEAS, DESIGNS AND
ARRANGEMENTS ARE, AND SHALL
REMAIN, THE PROPERTY OF C.B. HOME
DESIGN. NO PART SHALL BE COPIED,
REPRODUCED OR OTHERWISE USED,
DIRECTLY OR INDIRECTLY, IN WHOLE
OR IN PART, IN CONNECTION WITH ANY
OTHER WORK OR PROJECT WITHOUT
THE WRITTEN CONSENT OF C.B. HOME
DESIGN. VISUAL CONTACT WITH THESE
DRAWINGS AND/OR SPECIFICATIONS
SHALL CONSTITUTE A PRIMA FACIE
EVIDENCE OF ACCEPTANCE OF THESE
RESTRICTIONS.
116 SAN GABRIEL BLVD
SUITE P
ROSEMEAD, CA 91770
PHONE 626 279-67
HPDLOFEKRPH626#JPDLO.FRP
PROJECT ADDRESS:sheet no:
A-1
sheet title:OWNER INFO:DEMOLITION PLAN
revisions:
-
-
-
-
drawn by:
job number:
1/4" = 1'-0"
GC/JC/OP
CB20-212
SCALE:
n
C.B. HOME
D E S I G N
EXISTING FLOOR PLAN 607 E. BALBOA BLVD.NEWPORT BEACH, CA.92661(E) RESTROOM
DR. XERXEZ CALILUNGRAKEL APODACASAMUEL HERNANDEZPA2022-044
THESE DRAWINGS AND
SPECIFICATIONS, IDEAS, DESIGNS AND
ARRANGEMENTS ARE, AND SHALL
REMAIN, THE PROPERTY OF C.B. HOME
DESIGN. NO PART SHALL BE COPIED,
REPRODUCED OR OTHERWISE USED,
DIRECTLY OR INDIRECTLY, IN WHOLE
OR IN PART, IN CONNECTION WITH ANY
OTHER WORK OR PROJECT WITHOUT
THE WRITTEN CONSENT OF C.B. HOME
DESIGN. VISUAL CONTACT WITH THESE
DRAWINGS AND/OR SPECIFICATIONS
SHALL CONSTITUTE A PRIMA FACIE
EVIDENCE OF ACCEPTANCE OF THESE
RESTRICTIONS.
1168 SAN GABRIEL BLVD
SUITE P
ROSEMEAD, CA 91770
PHONE 626 279-5657
HPDLOFEKRPH626#JPDLO.FRP
PROJECT ADDRESS:sheet no:
A-2
sheet title:OWNER INFO:PROPOSED FLOOR PLAN
revisions:
-
-
-
drawn by:
job number:
1/4" = 1'-0"
GC/JC/OP
CB20-212
SCALE:
C.B. HOME
D E S I G N
FINISH SCHEDULE
(N) RECEPTION AREA
(N) TREATMENT #1
(N) CONSULT
DESCRIPTION FLOOR BASE COVE
(3/8" RADIUS)WALL
DRYWALL PAINTED
CEILING
DRYWALL PAINTED
EQUIPMENT SCHEDULE
8
OFFICE TABLE
DESCRIPTION
13
4
6
7
5
ITEM
1
NO.
2
4
1
QTY MANUFACTURER MODEL
9
(E) ELECTRIC MINI TANK WATER HEATER
HAND SINK
1
4
3
EMT
EQ. REMARKS
(N) SPA SPECIAL TREATMENT CHAIR
EEMAX
wall schedule
existing window schedule
door schedule :
legend
NOTES
1. ALL RESTROOMS AND EXITING / ENTRANCE DOORS TO BE SELF CLOSING.
2. ALL EQUIPMENT IS TO BE NSF AND INSTALLED TO NSF STANDARDS.
3. ALL EXIT/ENTRANCE DOORS SHALL BE TIGHT FITTING AND RODENT PROOF WITH
OPENING GAP BELLOW DOORS NOT TO EXCEED 1/4"
4. ALL COUNTERS SHALL BE ON 6' LEGS OR WITH A MINIMUM 3/8" RADIUS COVE
BASE TILE W/A MINIMUM 4" HIGH AT THE KICK SIDE OF COUNTERS.
5. LIGHT FIXTURES OVER OPEN FOOD AND UTENSIL WASH AREAS TO BE PROVIDED
WITH SHATTER PROOF COVERS.
6. ALL FOOD EQUIPMENT TO BE ON 6" HIGH LEGS OR ON CASTERS.
7. ALL EXTERIOR WINDOWS TO BE FIXED OR SCREENED IF OPENABLE.
8. INTERIOR OF COUNTER MUST BE FPR PANELING OR STAINLESS STEEL.
9. BATHROOM TO BE PROVIDED WITH LIGHT SWITCH ACTIVATED FAN AND DOOR TO
BE TIGHT FITTING.
10. IF ANY EXISTING ACCESSIBILITY ELEMENTS ARE NOT IN COMPLIANCE WITH
CURRENT CODE REQUIREMENTS , THEY SHALL BE UPGRADED TO THE
ACCESSIBILITY REQUIREMENTS SHOWN ON THESE PLANS.
11. LIGHT COLORED FRP PANELS TO HAVE A MINIMUM LIGHT REFLECTING VALUE
70% OR HIGHER.
12. WALL AND CEILING MATERIALS SHALL NOT EXCEED THE FLAME SPREAD
CLASSIFICATION IN CBC TABLE 803.9.
13. OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT
REQUIRE TIGHT GASPING, PINCHING OR TWISTING OF THE WRIST. FORCE
REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS MAXIMUM . CBC
11B-309.4
ROOM
SUPPLY / STORAGE ROOM
OCC. LOAD AREA
300 12
OCCUPANTS
1
TOTAL OCCUPANTS =8
OCCUPANT LOAD
6" H CERAMIC TILE CURB
W/ 5/8" RADIUS LIGHT COLOR
DRYWALL PAINTED 607 E. BALBOA BLVD.NEWPORT BEACH, CA.92661DRYWALL PAINTED
LOCATED ON TOP OF CEILING
WAITING AREA
BUSINESS AREAS
15
200 464
57
3
4
WAITING
57 SQ.FT.
(N)RECEPTION
83 SQ.FT.
(N) CONSULT
91 SQ.FT.
(N) TREATMENT #1
98 SQ.FT.
(N) TREATMENT #2
98 SQ.FT.
(N) TREATMENT #3
89 SQ.FT.
(N) MECH.
21 SQ.FT.
PROPOSED FLOOR PLAN
STERILE 40 SQ.FT.
(E) RESTROOM
HALLWAY 144 SQ.FT.(N) TREATMENT #2
(N) TREATMENT #3
(N) STERILE ROOM
(N) MECH. RM.
(N) SUPPLY CLOSET
(E) ADA RESTROOM CERAMIC TILE
DRYWALL PAINTED
5' H FRP PANEL SMOOTH, 6" H CERAMIC TILE W/ 5/8"
RADIUS LIGHT COLOR
DRYWALL PAINTED
DRYWALL PAINTED
DRYWALL PAINTED
DRYWALL PAINTED
CONTINUOUS LIGHT COLOR
CUSTOM CUSTOM
OFFICE CHAIRS CUSTOM
CHAIRS CUSTOM
CERAMIC TILE
CERAMIC TILE
CERAMIC TILE
CERAMIC TILE
CERAMIC TILE
CERAMIC TILE
CERAMIC TILE
CERAMIC TILE DRYWALL PAINTED
DRYWALL PAINTED
DRYWALL PAINTED
DRYWALL PAINTED
DRYWALL PAINTED
DRYWALL PAINTED
DRYWALL PAINTED
DRYWALL PAINTED
DRYWALL PAINTED
1
1
1
1
2
3
4
4
5 5 5
6
3
3
1
1
1
10 1
11 1
12 3
13 6
4
4
4
4
4
4
6" H CERAMIC TILE CURB
W/ 5/8" RADIUS LIGHT COLOR
6" H CERAMIC TILE CURB
W/ 5/8" RADIUS LIGHT COLOR
6" H CERAMIC TILE CURB
W/ 5/8" RADIUS LIGHT COLOR
6" H CERAMIC TILE CURB
W/ 5/8" RADIUS LIGHT COLOR
6" H CERAMIC TILE CURB
W/ 5/8" RADIUS LIGHT COLOR
6" H CERAMIC TILE CURB
W/ 5/8" RADIUS LIGHT COLOR
6" H CERAMIC TILE CURB
W/ 5/8" RADIUS LIGHT COLOR
DR. XERXEZ CALILUNGRAKEL APODACASAMUEL HERNANDEZSUPPLY
12 SQ.FT.
3
4
6
6
3
PA2022-044
THESE DRAWINGS AND
SPECIFICATIONS, IDEAS, DESIGNS AND
ARRANGEMENTS ARE, AND SHALL
REMAIN, THE PROPERTY OF C.B. HOME
DESIGN. NO PART SHALL BE COPIED,
REPRODUCED OR OTHERWISE USED,
DIRECTLY OR INDIRECTLY, IN WHOLE
OR IN PART, IN CONNECTION WITH ANY
OTHER WORK OR PROJECT WITHOUT
THE WRITTEN CONSENT OF C.B. HOME
DESIGN. VISUAL CONTACT WITH THESE
DRAWINGS AND/OR SPECIFICATIONS
SHALL CONSTITUTE A PRIMA FACIE
EVIDENCE OF ACCEPTANCE OF THESE
RESTRICTIONS.
116 SAN GABRIEL BLVD
SUITE P
ROSEMEAD, CA 91770
PHONE 626 279-67
HPDLOFEKRPH626#JPDLO.FRP
PROJECT ADDRESS:sheet no:
A-3
sheet title:OWNER INFO:EXISTING CEILING PLAN
revisions:
-
-
-
-
drawn by:
job number:
1/4" = 1'-0"
GC/JC/OP
CB20-212
SCALE:
C.B. HOME
D E S I G N
CEILING SCHEDULE
EXIT
EXISTING CEILING PLAN
n
WAITING
57 SQ.FT.
(N)RECEPTION
83 SQ.FT.
(N) CONSULT
91 SQ.FT.
(N) TREATMENT #1
98 SQ.FT.
(N) TREATMENT #2
98 SQ.FT.(N) TREATMENT #3
89 SQ.FT.
(N) MECH.
21 SQ.FT.STERILE
40 SQ.FT.
SUPPLY
12 SQ.FT.
(E) ADA
RESTROOM
HALLWAY 144 SQ.FT.EXITEXIT DR. XERXEZ CALILUNGRAKEL APODACASAMUEL HERNANDEZ607 E. BALBOA BLVD.NEWPORT BEACH, CA.92661PA2022-044
EXTEND GYP BD TO TOP
RUNNER W/ #6 1-1/2"
DRYWALL SCREW@ 36" O.C.
5" SMOOTH CERAMIC
TILE COVE BASE
CERAMIC TILE FLOOR
5/8" TYPE X GYP BD EACH SIDE W/ #6 1-1/2"
DRYWALL SCREW @ 12" O.C.
2 X 6 WOOD STUDS
@ 16" O.C.
2X6 TREATED WOOD BASE
2X6 WOOD BLOCKING @ 4'-6" VERTICAL
(2) 2X6 WOOD
HEADER
5" SMOOTH CERAMIC TILE
COVE BASE
5/8" TYPE X GYP BD W/ #6
1-1/2" DRYWALL SCREW @ 12"
O.C. PAINTED W/ SMOOTH
SEMI-GLOSS PAINT (SEE
FINISH SCHEDULE)
2 X 8 BEAMS
@ 16" O.C.
2 X 8 BLOCKING
@ 48" O.C.
HILTI KWIKBOLT 3 (KB3) CONCRETE
ANCHOR 3-1/2" MINIMUM 1-1/2" EMBED
DEPTH @ 36" O.C.
ICC ESR #2302 LARR #25741
(SPECIAL INSPECTION FOR SECTION 4.4
OF ICC LISTING REPORT)
R-19 INSULATION
FOR CEILING
R-11 INSULATION
FOR WALL
2 X 8 HANGER
THESE DRAWINGS AND
SPECIFICATIONS, IDEAS, DESIGNS AND
ARRANGEMENTS ARE, AND SHALL
REMAIN, THE PROPERTY OF C.B. HOME
DESIGN. NO PART SHALL BE COPIED,
REPRODUCED OR OTHERWISE USED,
DIRECTLY OR INDIRECTLY, IN WHOLE
OR IN PART, IN CONNECTION WITH ANY
OTHER WORK OR PROJECT WITHOUT
THE WRITTEN CONSENT OF C.B. HOME
DESIGN. VISUAL CONTACT WITH THESE
DRAWINGS AND/OR SPECIFICATIONS
SHALL CONSTITUTE A PRIMA FACIE
EVIDENCE OF ACCEPTANCE OF THESE
RESTRICTIONS.
116 SAN GABRIEL BLVD
SUITE P
ROSEMEAD, CA 91770
PHONE 626 279-5657
HPDLOFEKRPH626#JPDLO.FRP
PROJECT ADDRESS:sheet no:
A-4
sheet title:OWNER INFO:DETAILS
revisions:
-
-
-
-
drawn by:
job number:
1/4" = 1'-0"
GC/JC/OP
CB20-212
SCALE:
C.B. HOME
D E S I G N
DETAIL - 1
DETAIL - 2
DETAIL - 3
DETAIL - 4
DETAIL - 5
DETAIL - 6 DR. XERXEZ CALILUNGRAKEL APODACASAMUEL HERNANDEZ607 E. BALBOA BLVD.NEWPORT BEACH, CA.92661PA2022-044
THESE DRAWINGS AND
SPECIFICATIONS, IDEAS, DESIGNS AND
ARRANGEMENTS ARE, AND SHALL
REMAIN, THE PROPERTY OF C.B. HOME
DESIGN. NO PART SHALL BE COPIED,
REPRODUCED OR OTHERWISE USED,
DIRECTLY OR INDIRECTLY, IN WHOLE
OR IN PART, IN CONNECTION WITH ANY
OTHER WORK OR PROJECT WITHOUT
THE WRITTEN CONSENT OF C.B. HOME
DESIGN. VISUAL CONTACT WITH THESE
DRAWINGS AND/OR SPECIFICATIONS
SHALL CONSTITUTE A PRIMA FACIE
EVIDENCE OF ACCEPTANCE OF THESE
RESTRICTIONS.
116 SAN GABRIEL BLVD
SUITE P
ROSEMEAD, CA 91770
PHONE 626 279-67
ePaLlcbhoPe626#JPaLl.coP
C.B. HOME
D E S I G N
1.IF A MINIMUM 9 INCHES HEIGHT OF TOE CLEARANCE IS PROVIDED, A MAXIMUM OF 6 INCHES OF THE 48
INCHES OF CLEAR FLOOR SPACE REQUIRED AT THE FIXTURE MAY EXTEND INTO THE TOE SPACE.
2.
3. IN BUILDINGS AND FACILITIES, FLOORS OF A GIVEN STORY SHALL BE A COMMON LEVEL THROUGHOUT,
OR SHALL BE CONNECTED BY PEDESTRIAN RAMPS, PASSENGER ELEVATORS OR SPECIAL ACCESS
LIFTS.
4. GROUND AND FLOOR SURFACES ALONG ACCESSIBLE ROUTES AND IN ACCESSIBLE ROOMS AND
SPACES, INCLUDING FLOORS, WALKS, STAIR AND CURB RAMPS, SHALL BE STABLE, FIRM AND SLIP
RESIST.
5. CHANGES IN LEVEL UP TO 1/4" MAY BE VERTICAL AND WITHOUT EDGE TREATMENT.
6. CHANGES IN LEVEL BETWEEN 1/4" AND 1/2" SHALL BE ACCOMPLISHED BY MEANS OF RAMP NO STEEPER
THAN 1 VERT. TO 2 HORIZONTAL.
7. CHANGES IN LEVEL GREATER THAN 1/2 INCH SHALL BE MEANS OF A CURB RAMP, RAMP OR ELEVATOR.
8. IF CARPET OR CARPET TILE IS USED ON A GROUND OR FLOOR SURFACE, IT SHALL BE SECURELY
ATTACHED; HAVE A FIRM CUSION, PAD BACK OR NO CUSION OR PAD; HAVE A LEVEL LOOP, LEVEL CUT
PILE OR LEVEL CUT/UNCUT PILE TEXTURE. THE MAX.
9. IF GRATINGS AR LOCATED ON FLOORS, THEN THEY SHALL HAVE SPACES NO GREATER THAN 1/2 INCH
WIDE IN ONE DIRECTION. IF GRATINGS HAVE ELONGATED OPENINGS, THEN THEY SHALL BE PLACED SO
THAT THE LONG DIMENSION IS PERPENDICULAR TO DOMINANT DIRECTION OF TRAVEL.
* DOOR THRESHOLDS LANDINGS OR FLOOR LEVEL AT DOORS
SHALL NOT BE MORE THAN 1
2 INCH BELOW THE THRESHOLD.
RAISED THRESHOLDS AND FLOOR LEVEL CHANGES
GREATER THAN 14 INCH AT DOORWAYS SHALL BE BEVELED
WITH A SLOPE NOT GREATER THAN ONE UNIT VERTICAL IN
TWO UNITS HORIZONTAL.
2
NOTE:
THE MAXIMUM EFFORT TO OPERATE DOOR HARDWARE SHALL BE 5
POUNDS FORCE FOR THE EXTERIOR DOORS AND 5 POUNDS FORCE FOR
THE INTERIOR DOORS. THE LOWER 10 INCHES OF THE DOOR SHALL HAVE
A SMOOTH PANEL ON THE PUSH SIDE OF THE DOOR WHICH WILL ALLOW
THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT
CREATING A TRAP OR HAZARD.
PUSH SIDE
THIS APPLIES IF BOTH LATCHAND CLOSER ARE PRESENT
PULL SIDE
EXTERIOR
INTERIOR
2'-0" MIN.
18" MIN.
12"
4'-0" MIN.4'-0" MIN.5'-0" MIN.30" MIN.48" MIN.
19" MIN.
SCALE: N.T.S1SCALE: N.T.S
6
(A)(B)
(A)
(B)
ENTRANCES & EXITS
NOTE:EXIT AS DEFINEDIS "A CONTINUOUS&UNOBSTRUCTEDMEANSOF EGRESSTO A PUBLICWAY
&SHALLINCLUDEINTERVENINGAISLES,DOORS,DOORWAYS,GATES,CORRIDORS,EXTERIOREXIT
BALCONIES, RAMP
NOTE:PUBLICWAY AS DEFINEDIS "ANY STREET,ALLEYOR SIMILARPARCEL OF LAND ESSENTIALLY
UNOBSTRUCTEDFROM THE GROUND TO THE SKY WHICH IS DEEDED,DEDICATED,OR OTHERWISE
PERMANENTLYAPPROPRIATEDTO THE PUBLIC FOR PUBLIC USE &HAVINGA CLEAR WIDTHOF NOT
LESS THAN 10'.NOTE:FOR THE PURPOSES OF TITLE 24,THE USE OF THE TERM EXIT DOOR IN
SECTION3304 APPLIESTO ALL DOORSTHAT PROVIDEACCESS,THAT IS,ENTRANCES,PASSAGE,DOORS,
C.)
1.ALL ENTRANCESAND ALL EXTERIORGROUNDFLOOR EXIT DOORS TO BUILDINGS&FACILITIES
SHALL MADE ACCESSIBLE PERSONS WITH DISABILITIES.
2.ELEVATORS ESCALATORS SHALL NOT USED REQUIRED EXIT.
3.REVOLVING DOORS SHALL NOT BE USED AS A REQUIRED ENTRANCE FOR PERSONS WITH
DISABILITIES.
4.DURINGPERIODSOF PARTIALOR RESTRICTEDUSE OF A BUILDINGOR FACILITY,THE ENTRANCES
USED FOR PRIMARY ACCESS SHALL ACCESSIBLE AND USABLE PERSON WITH DISABILITIES.
5.RECESSEDDOORMATSSHALL BE ADEQUATELYANCHOREDPREVENTINTERFERENCEWITH WITH
WHEELCHAIR TRAFFIC.
6.ALL GATES,INCLUDING TICKET GATES,SHALL MEET ALL APPLICABLE ACCESSIBILITY
SPECIFICATIONS DOORS.
7.EVERY REQUIREDEXIT DOORWAYWHICH IS LOCATEDWITHINAN ACCESSIBLEPATH OF TRAVEL
SHALL BE OF A SIZE AS TO PERMITTHE INSTALLATIONOF A DOOR NOT LESS THAN 3'IN WIDTH&
NOT LESS THEN 6'-8" HEIGHT.
8.THE SPACEBETWEEN2 CONSECUTIVEDOOROPENINGSIN A VESTIBULE,SERVING OTHERTHAN A
REQUIREDEXITSTAIRWAY,SHALLPROVIDEA MINIMUMOF 48"OF CLEARSPACEFROMANYDOOR
OPENINGINTO SUCH VESTIBULEWHEN THE DOOR IS POSITIONEDAT AN ANGLE OF 90 DEGREES
FROMITS CLOSEDPOSITION.DOORSIN A SERIESSHALLSWINGEITHERIN THE SAME DIRECTION
OR AWAY FROM THE SPACE BETWEEN THE DOORS.
9.IN EXISTING STAIRWAYS WHERE THERE IS NO LANDING,DOORS SHALL BE CONSPICUOUSLY
MARKED WITH A SIGN STATING"DANGER!STAIRWAY--NOLANDING"OR EQUIVALENTWORDING &
THERE SHALL ADEQUATE ILLUMINATION.
3
11
SCALE: N.T.S 10
SCALE: N.T.S
9SCALE: N.T.S
NOTE:
GRAB BARS SHALL COMPLY WITH SECTION 11B-609. A SIDE-WALL GRAB
BAR COMPLYING WITH SECTION 11B-604.5.1 SHALL BE PROVIDED AND
SHALL BE LOCATED ON THE WALL CLOSEST TO THE WATER CLOSET. IN
ADDITION, A REAR-WALL GRAB BAR COMPLYING WITH SECTION
11B-604.5.2 SHALL BE PROVIDED. WHERE SEPARATE GRAB BARS ARE
REQUIRED ON ADJACENT WALLS AT A COMMON MOUNTING HEIGHT, AN
L-SHAPED GRAB BAR MEETING THE DIMENSIONAL REQUIREMENTS OF
SECTIONS 11B-604.5.1 AND 11B-604.5.2 SHALL BE PERMITTED.
ROUTE EXITEXITSTAIR
EXIT
DOWN
6"
6"
6"
6"
5"
3"
FIGURE: 11B-308.3.1
7
5SCALE: N.T.S
sheet no:
ADA-1
ADA RESTROOM DETAILS
34SCALE: N.T.S PROJECT ADDRESS:OWNER INFO:revisions:
-01/12/21
-
-
-
drawn by:
job number:
1/4" = 1'-0"
GC/JC/OP
SCALE:
CB20-212
sheet title:
8N.T.S
ELECTRICAL CONTROLS AND SWITCHES INTENDED TO BE USED BY THE
OCCUPANT OF A ROOM OR AREA TO CONTROL LIGHTING AND
RECEPTACLE OUTLETS, APPLIANCES OR COOLING, HEATING AND
VENTILATING EQUIPMENT SHALL BE LOCATED WITHIN ALLOWABLE
REACH RANGES. LOW REACH SHALL BE MEASURED TO THE BOTTOM OF
THE OUTLET BOX AND HIGH REACH SHALL BE MEASURED FROM THE TOP
OF THE OUTLET BOX CBC 11B-206.2.8 607 E. Balboa Blvd.Newport Beach, CA.92661(E) RESTROOM
A
SOAP DISPENSER
B
C
D
E
F
G
H
I
1. THE EXHAUST FAN TO BE ACTIVATED W/LIGHT SWITCH NOTE:
RESTROOM EXISTING FIXTURES AND ACCESSORIES:
ELONGATED FLOOR MOUNTED WATER CLOSET (H'CAP ACCESSIBLE) CPC 411.1
SEE DETAIL 4 / ADA-1
1 1/2" S.S. GRAB BAR @ 34" A.F.F. (42"L @ SIDE & 36"L @ BACK)
TOILET PAPER HOLDER @ 24" A.F.F.
TOILET-SEAT-COVER DISP. (@ 44 1/2" (TOP) A.F.F. IN H'CAP COMP.)
PAPER TOWEL DISP. & WASTE RECEPTACLE (H'CAP ACCESSIBLE)
MIRROR (H'CAP ACCESSIBLE) TO 7'H
RESTROOM A.D.A. SYMBOL SEE DTL. 2 / ADA-2
DROP-IN LAVATORIES W/ HOT/COLD WATER SUPPLY
(H'CAP ACCESSIBLE, 34" A.F.F. MAX.) (DETAIL 1/ADA-2)
J
2. SEE DETAIL 1/ADA-1 FOR MORE ADA RESTROOM REQUIREMENTS.
LIGHT SWITCH ACTIVATED VENTILATION FAN
GRAB BARS IN TOILET FACILITIES AND
BATHING FACILITIES SHALL COMPLY WITH
SECTION 11B-609
A
C D
J
I
B
HFG
E
SCALE: 1/4" =1'-0" DR. XERXEZ CALILUNGRAKEL APODACASAMUEL HERNANDEZ11B-305.2 FLOOR OR GROUND SURFACE. FLOOR OR GROUND SURFACES OF A CLEAR FLOOR OR GROUND SPACE SHALL COMPLY WITH SECTION 11B-302. CHANGES IN LEVEL ARE NOT PERMITTED.
EXCEPTION: SLOPES NOT STEEPER THAN 1:48 SHALL BE PERMITTED.
11B-404.1 GENERAL. DOORS, DOORWAYS AND GATES THAT ARE PART OF AN ACCESSIBLE ROUTE SHALL COMPLY WITH SECTION 11B-404.
EXCEPTIONS:
1. DOORS, DOORWAYS AND GATES DESIGNED TO BE OPERATED ONLY BY SECURITY PERSONNEL SHALL NOT BE REQUIRED TO COMPLY WITH SECTIONS 11B-404.2.7, 11B-404.2.8, 11B-404.2.9, 11B-404.3.2 AND 11B-404.3.4 THROUGH 11B-404.3.7. A SIGN VISIBLE FROM THE APPROACH SIDE COMPLYING WITH SECTION 11B-703.5 SHALL BE POSTED STATING "ENTRY RESTRICTED AND CONTROLLED BY
SECURITY PERSONNEL".
2. AT DETENTION AND CORRECTIONAL FACILITIES, DOORS, DOORWAYS AND GATES DESIGNED TO BE OPERATED ONLY BY SECURITY PERSONNEL SHALL NOT BE REQUIRED TO COMPLY WITH SECTIONS 11B-404.2.7, 11B-404.2.8, 11B-404.2.9, 11B-404.3.2 AND 11B-404.3.4 THROUGH 11B-404.3.7.
11B-404.2 MANUAL DOORS, DOORWAYS, AND MANUAL GATES. MANUAL DOORS AND DOORWAYS AND MANUAL GATES INTENDED FOR USER PASSAGE SHALL COMPLY WITH SECTION 11B-404.2.
11B-404.2.1 REVOLVING DOORS, GATES, AND TURNSTILES. REVOLVING DOORS, REVOLVING GATES AND TURNSTILES SHALL NOT BE PART OF AN ACCESSIBLE ROUTE.
11B-404.2.2 DOUBLE-LEAF DOORS AND GATES. AT LEAST ONE OF THE ACTIVE LEAVES OF DOORWAYS WITH TWO LEAVES SHALL COMPLY WITH SECTIONS 11B-404.2.3 AND 11B-404.2.4.
11B-404.2.4.1 SWINGING DOORS AND GATES. SWINGING DOORS AND GATES SHALL HAVE MANEUVERING CLEARANCES COMPLYING WITH TABLE 11B-404.2.4.1.
11B-404.2.4.3 RECESSED DOORS AND GATES. MANEUVERING CLEARANCES FOR FORWARD APPROACH SHALL BE PROVIDED WHEN ANY OBSTRUCTION WITHIN 18 INCHES OF THE LATCH SIDE AT AN INTERIOR DOORWAY, OR WITHIN 24 INCHES OF THE LATCH SIDE OF AN EXTERIOR DOORWAY, PROJECTS MORE THAN 8 INCHES BEYOND THE FACE OF THE DOOR, MEASURED PERPENDICULAR TO THE
FACE OF THE DOOR OR GATE.
11B-404.2.8.1 DOOR CLOSERS & GATE CLOSERS. DOOR CLOSERS & GATE CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90 DEGREES, THE TIME REQUIRED TO MOVE THE DOOR TO A POSITION OF 12 DEGREES FROM LATCH IS 5 SECONDS MINIMUM.
11B-404.2.9 DOOR AND GATE OPENING FORCE. THE FORCE FOR PUSHING OR PULLING OPEN A DOOR OR GATE SHALL BE AS FOLLOWS: (THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT BOLTS OR DISENGAGE OTHER DEVICES THAT HOLD THE DOOR OR GATE IN A CLOSED POSITION)
1. INTERIOR HINGED DOORS AND GATES: 5 LBS MAXIMUM.
2. SLIDING OR FOLDING DOORS: 5 LBS MAXIMUM.
3. REQUIRED FIRE DOORS: THE MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY, NOT TO EXCEED 15 LBS.
4. EXTERIOR HINGED DOORS: 5 LBS MAXIMUM.
11B-404.2.10 DOOR AND GATE SURFACES. SWINGING DOOR AND GATE SURFACES WITHIN 10 INCHES OF THE FINISHED FLOOR OR GROUND MEASURED VERTICALLY SHALL HAVE A SMOOTH SURFACE ON THE PUSH SIDE EXTENDING THE FULL WIDTH OF THE DOOR OR GATE. PARTS CREATING HORIZONTAL AND VERTICAL JOINTS IN THESE SURFACES SHALL BE WITHIN 1/16 INCH OF THE SAME PLANE
AS THE OTHER AND BE FREE OF SHARP OR ABRASIVE EDGES. CAVITIES CREATED BY ADDED LICK PLATES SHALL BE CAPPED.
EXCEPTIONS:
1. SLIDING DOORS SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-404.2.10.
2. TEMPERED GLASS DOORS WITHOUT STILES AND HAVING A BOTTOM RAIL OR SHOE WITH THE TOP LEADING EDGE TAPERED AT 60 DEGREES MINIMUM FROM HORIZONTAL SHALL NOT BE REQUIRED TO MEET THE 10 INCH BOTTOM SMOOTH SURFACE HEIGHT REQUIREMENT.
3. DOORS AND GATES THAT DO NOT EXTEND TO WITHIN 10 INCHES OF THE FINISH FLOOR OR GROUND SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B404.2.10.
FRONT APPROACH,
PUSH SIDE, DOOR
W/ CLOSER & LATCH
HINGE APPROACH,
PULL SIDE
LATCH APPROACH,
PULL SIDE
HINGE APPROACH,
PUSH SIDE, DOOR
W/ CLOSER & LATCH
LATCH APPROACH,
PULL SIDE
HINGE APPROACH,
PUSH SIDE = LEVEL & CLEAR FLOOR OR LANDING
LATCH APPROACH,
PUSH SIDE, DOOR
W/ CLOSER
FRONT APPROACH,
PUSH SIDE
FRONT APPROACH,
PUSH SIDE
PA2022-044
THESE DRAWINGS AND
SPECIFICATIONS, IDEAS, DESIGNS AND
ARRANGEMENTS ARE, AND SHALL
REMAIN, THE PROPERTY OF C.B. HOME
DESIGN. NO PART SHALL BE COPIED,
REPRODUCED OR OTHERWISE USED,
DIRECTLY OR INDIRECTLY, IN WHOLE
OR IN PART, IN CONNECTION WITH ANY
OTHER WORK OR PROJECT WITHOUT
THE WRITTEN CONSENT OF C.B. HOME
DESIGN. VISUAL CONTACT WITH THESE
DRAWINGS AND/OR SPECIFICATIONS
SHALL CONSTITUTE A PRIMA FACIE
EVIDENCE OF ACCEPTANCE OF THESE
RESTRICTIONS.
116 SAN GABRIEL BLVD
SUITE P
ROSEMEAD, CA 91770
PHONE 626 279-67
HPDLOFEKRPH626#JPDLO.FRP
C.B. HOME
D E S I G N36" STEEL
GRAB BAR
FIG. 5.5 TOILET COMPARTMENT
ELEVATION N.T.S.
1 12" DIAMETER GRAB BAR W/
PEENED FINISH & 250 LBS.
CAPACITY
TOILET SEAT
DISPENSER (WHERE
OCCURS)
17" TO
19" TO
TOP OF
TOILET
SEAT
ROLL PAPER HOLDER
WITHOUT STOPS 19" MIN HT.
MIN. 1 1/2" CLEAR
BETWEEN TANK TOP
AND GRAB BAR
SURFACE
17" TO 19" TO TOP
OF TOILET SEAT
12"
MAX.
24"12"
27" MIN
2'-5" MIN
1'-6"
34" MIN
40" MAX
LAVATORY
MIN. 6-1/2" DEEP
LAVATORY
36"
14"
7"
9"
17" MAX
44" MAX
30"
URINAL RIM SHALL PROJECT
MIN. 14" FROM WALL
PAPER TOWEL
DISPENSER SOAP
DISPENSER
NAPKIN
DISPOSAL
MIRROR
17"MIN-18"MAX
INSULATED
DRAIN PIPE
SHALL COMPLY
W/ ASME A112.18.9
36"
42" MIN.
54" MIN
URINAL SIDE VIEW
17"
13-1/2"
1
DOOR MOUNTED SIGNAGE (TYP)
UPPERCASECHARACTERS
GRADE II BRAILLE
CORRESPONDING
HEIGHT OF LETTERING
5/8" MIN TO 2" MAX
TO CENTERLINE OF SIGN FROM FLOOR
LETTERING RAISED 1/32"
WALL MOUNTED SIGNAGE TO BE LOCATED ON LATCHSIDE OF DOOR, CLEAR OF DOOR-SWING. MOUNT AT 60"
MEN
REQUIRED ON DOOR-MOUNTED SIGNAGE.NOTE: PICTOGRAMS AND/OR LETTERING ARE NOT
DOOR-MOUNTED
SIGNAGE
MENWOMEN
RESTROOMS UNISEX
CL
SCALE: N.T.S
3SCALE: N.T.S
F.F
sheet no:
ADA-2
ADA RESTROOM DETAILS
2SCALE: N.T.S
PROJECT ADDRESS:OWNER INFO:revisions:
-01/12/21
-
-
-
drawn by:
job number:
1/4" = 1'-0"
GC/JC/OP
SCALE:
CB20-212
sheet title:
(F) LATCH SIDE APPROACH
SLIDING DOORS
(D) FRONT APPROACH SLIDING
DOORS48" MIN.24" MIN.42" MIN.MINIMUM CLEAR WIDTH
FOR SINGLE WHEELCHAIR
CLEAR WIDTH FOR TWO WHEEL
CHAIRS TO PASS PARALLEL
THROUGH CORRIDOR
60" MIN.60" MIN.32"
MIN.
36" MIN*24"MAX.48" MIN.24"MAX.32"
MIN.
4N.T.S
ACCESSIBLE PATH OF TRAVEL 48" MIN.30"MIN.19"MIN.30"
MIN.48" MIN.19" MIN.30"MIN.42" MIN.30" MIN.
5N.T.S
DR. XERXEZ CALILUNGRAKEL APODACASAMUEL HERNANDEZ607 E. BALBOA BLVD.NEWPORT BEACH, CA.92661PA2022-044
HNOCCUPANCY SENSORUNCONTROLLED RECEPTACLECONTROLLED RECEPTACLESPLIT WIRED RECEPTACLE, ONE CONTROLLED, ONE UNCONTROLLEDCOMPLY WITH T-24, 130.5(d)S2P100AMAEXISTING "MS"(E)120/240V, 1Ø,3WSINGLE LINE DIAGRAM(E)(E)REVISIONS JS ENGINEERING, INC.STAMPTENANT IMPROVEMENT-DENTAL OFFICE
607 E. BALBOA BLVD., NEWPORT BEACH, CA.92661 E1PA2022-044
REVISIONS
ITEM
1
NO.
2
3
4
5
6
7
8
9
10
11
12
13
EQUIPMENT SCHEDULE
DESCRIPTION
(E) GARAGE
QTY
4
1
1
4
3
1
1
1
1
1
1
3
6
E
E
E
E
(N) SPA SPECIAL TREATMENT CHAIR
(E) ELECTRIC MINI TANK WATER HEATER
HAND SINK
OFFICE CHAIRS
CHAIRS
OFFICE TABLE
EEMAX
CUSTOM
CUSTOM
CUSTOM
EMT
CUSTOM
LOCATED ON TOP OF CEILING
MANUFACTURER MODEL EQ. REMARKS (NOT PART OF SCOPE)
S
S
POWER PLAN
1/4"=1'-0"
LIGHTING PLAN
1/4"=1'-0"
STAMP
E2SUBSUBTENANT IMPROVEMENT-DENTAL OFFICE607 E. BALBOA BLVD., NEWPORT BEACH, CA.92661JS ENGINEERING, INC.PA2022-044
REVISIONS JS ENGINEERING, INC.STAMPTENANT IMPROVEMENT-DENTAL OFFICE
607 E. BALBOA BLVD., NEWPORT BEACH, CA.92661 E3PA2022-044
1ACITEMMECHANICAL EQUIPMENT SCHEDULEREVISIONS JS ENGINEERING, INC.STAMPTENANT IMPROVEMENT-DENTAL OFFICE
607 E. BALBOA BLVD., NEWPORT BEACH, CA.92661 M1PA2022-044
ROOF PLAN1/4"=1'-0"CEILING PLAN1/4"=1'-0"FLOOR PLAN1/4"=1'-0"EESUB
EESUB (E) GARAGE(NOT PART OF SCOPE)EXITEXIT
REVISIONS JS ENGINEERING, INC.STAMPTENANT IMPROVEMENT-DENTAL OFFICE
607 E. BALBOA BLVD., NEWPORT BEACH, CA.92661 M2PA2022-044
REVISIONS JS ENGINEERING, INC.STAMPTENANT IMPROVEMENT-DENTAL OFFICE
607 E. BALBOA BLVD., NEWPORT BEACH, CA.92661 M3PA2022-044
DOMESTIC WATER PIPING SIZINGFIXTURE CONNECTION SCHEDULE (BRANCH SIZES)PIPE MATERIALSSERVICESLOCATIONMATERIALJOININGMETHODREMARKSDOMESTICCOLD & HOTWATERUNDERGROUNDRIGID COPPER( TYPE K)BRAZEDNOT TO EXCEED 20 OF I PERCENT JOINT FITTINGS. SHOULD STREETPRESSURE EXCEED 80 PSI, A PRESSURE REDUCING VALVE ASSEMBLYSHALL BE INSTALLED. NO JOINTS SHALL BE ALLOWED UNDERBUILDING SLAB. GATE VALVES SHALL BE BRONZE WITH ENDS TOSUITE PIPE, NONRISING STEM FOR 150 PSI WORKING PRESSURE.ABOVEUNDERGROUNDRIGID COPPER( TYPE L)SOLDEREDSANITARY WASTE SEWERUNDERGROUNDCAST IRON SOIL PIPE & FITTINGSOR OTHER APPROVED MATERIALHUBLESSABOVEGROUNDCAST IRON SOIL PIPE & FITTINGSOR OTHER APPROVED MATERIALHUBLESSSANITARY WASTE VENTABOVEGROUNDCAST IRON SOIL PIPE & FITTINGSOR OTHER APPROVED MATERIALHUBLESSLOW PRESSUREGASUNDERGROUND SCHEDULE 40 BLACK STEEL WELDEDPROVEIDE APPROVED GAS PRESSUSRE REGULATORS. NATURAL GASRIGHTAND LEFT HAND NIPPLES AND COUPLINGS SHALL BE NEW BLACKIRON, UNIONS SHALL NOT BE USED EXCEPT AT UNITS AND VAVLES.ABOVEUNDERGROUNDSCHEDULE 40 BLACK STEEL WELDEDABS PIPE MAY BE USED WHEN FIRST APPROVED BY THEADMINISTRATIVE AUTHORITYABS PIPE MAY BE USED WHEN FIRST APPROVED BY THEADMINISTRATIVE AUTHORITYABS PIPE MAY BE USED WHEN FIRST APPROVED BY THEADMINISTRATIVE AUTHORITYPLUMBING ABBREVIATIONSPLUMBING LEGENDMISC. EQUIPMENT SCHEDULEMEP COMPONENT ANCHORAGE NOTEPIPING SYSTEM BRACING NOTEGENERAL NOTESDOMESTIC WATER CALCULATION REVISIONS JS ENGINEERING, INC.STAMPTENANT IMPROVEMENT- DENTAL OFFICE
607 E. BALBOA BLVD. NEWPORT BEACH, CA.92661 P1PA2022-044
REVISIONS
ITEM
1
NO.
2
3
4
5
6
7
8
9
10
11
12
13
EQUIPMENT SCHEDULE
DESCRIPTIONQTY
4
1
1
4
3
1
1
1
1
1
1
3
6
(N) SPA SPECIAL TREATMENT CHAIR
(E) ELECTRIC MINI TANK WATER HEATER
HAND SINK
OFFICE CHAIRS
CHAIRS
OFFICE TABLE
EEMAX
CUSTOM
CUSTOM
CUSTOM
EMT
CUSTOM
LOCATED ON TOP OF CEILING LEGEND
MANUFACTURER MODEL EQ. REMARKS
E
E
E
E
2
10
9
811 3
7
11 3
7
10
9
8
2
12 12
1
1
1
1
12 12
1 1
STAMP
WAITING
(N) CONSULT
WAITING
FLOOR PLAN (WASTE & VENT)
1/4"=1'-0"
FLOOR PLAN (HOT & COLD)
1/4"=1'-0"P2SUBHALLWAY 144 SQ.FT.SUBHALLWAY 144 SQ.FT.TENANT IMPROVEMENT- DENTAL OFFICE607 E. BALBOA BLVD. NEWPORT BEACH, CA.92661JS ENGINEERING, INC.PA2022-044
REVISIONS
E
E
E
E
2
10
9
811 3
7
11 3
7
10
9
8 11 3
7
2
10
9
8
E
E
2
12 12
1
1
1
1
1
1
12
12 12
1 1 1
12
WAITING
(N) CONSULT (N) CONSULT (N) CONSULT
WAITING WAITING
STAMP
FLOOR PLAN (DENTAL AIR LINE)
1/4"=1'-0"
FLOOR PLAN (DENTAL VACUUM LINE)
1/4"=1'-0"
FLOOR PLAN (DENTAL WATER LINE)
1/4"=1'-0"P3SUBHALLWAY 144 SQ.FT.SUBHALLWAY 144 SQ.FT.SUBHALLWAY 144 SQ.FT.TENANT IMPROVEMENT- DENTAL OFFICE607 E. BALBOA BLVD. NEWPORT BEACH, CA.92661JS ENGINEERING, INC.PA2022-044