HomeMy WebLinkAboutPA2022-067_20220323_Plans_42x30DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED, ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL THEN BE HELD HARMLESS AND ABSOLVED OF ANY LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
SHEET LISTCODE INFORMATIONSITE INFORMATIONPROJECT STATISTICSDEFERRED SUBMITTALSPROJECT DESCRIPTION
VICINITY MAPSPECIAL INSPECTIONSSHORING & EXCAVATIONAGENCIES & SERVICES PROJECT DIRECTORY
13
24
57
68
911
10BRANDON ARCHITECT
STRUCTURAL ENGINEER
INTERIOR DESIGNER
ENERGY CONSULTANT
BRANDON ARCHITECTS, INC.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
P: 714.454.4040
WWW.BRANDONARCHITECTS.COM
OWNER
CIVIL ENGINEER
LANDSCAPE DESIGNER
MEP CONSULTANT
GENERAL CONTRACTOR
GEOTECHNICAL ENGINEER
SURVEYORARCHITECTS, INC.BRANDON ARCHITECTS
03-22-2022
TITLE SHEETOCEAN FRONT POOL HOUSESMITH 507 LLC
1616 W. OCEAN FRONT,
NEWPORT BEACH , CA 92663
CDP SUBMITTAL
1616 W. OCEAN FRONT, NEWPORT
BEACH , CA 92663
T-1.0
OCEAN FRONT POOL HOUSE
1616 W. OCEAN FRONT, NEWPORT BEACH , CA 92663
**0000-2021**
ELIZABETH HANNA
SMITH 507 LLC
1616 W. OCEAN FRONT,
NEWPORT BEACH , CA 92663
ANDREW PATTERSON
PATTERSON CUSTOM HOMES
15 CORPORATE PLAZA, SUITE 150
NEWPORT BEACH, CA 92660
P: 949.723.1800
COAST GEOTECHNICAL
1200 W. COMMONWEALTH
FULLERTON, CA 92833
P: 714.448.1620
APEX LAND SURVEYING, INC.
PAUL CRAFT, LIC. NO. 8516
17853 SANTIAGO BLVD, STE. 107-285
VILLA PARK, CA 92861
P:949.488.5006
TBDTBD
TBD TOAL ENGINEERING
139 AVENIDA NAVARRO
SAN CLEMENTE, CA, 92672
P: 714.870.1211
TBD TBD
TOTAL BUILDING AREA SCHEDULE
NAMEAREA
LIVING
THIRD FLOOR LIVING246 SF
SECOND FLOOR LIVING663 SF
FIRST FLOOR LIVING1378 SF
LIVING2287 SF
GARAGE
2-CAR GARAGE476 SF
GARAGE476 SF
GRAND TOTAL2763 SF
OUTDOOR AREA SCHEDULE
NAMEAREA
2ND FLOOR BALCONY158 SF
BALCONY84 SF
FRONT ENTRY101 SF
COVERED LOUNGE DECK223 SF
DECK261 SF
MECH.54 SF
PATIO397 SF
PLANTED48 SF
PLANTED8 SF
POOL AREA1042 SF
GRAND TOTAL2376 SF
LEGAL DESCRIPTION:
LOT INFORMATION:
ZONED: R-2 TWO-UNIT RESIDENTIAL
SITE AREA: 3,075 S.F. BUILDABLE AREA: 2,241 S.F.
TOTAL ALLOWABLE AREA: 2 X 2,241 S.F. = 4,482 S.F.
REQ'D. OPEN VOLUME = 2,241 S.F. X .15 = 336 S.F. (7'-6" HT. MIN.)
TOTAL ALLOWABLE THIRD FLOOR AREA = 336 S.F.
EXISTING BUILDING INFORMATION:
VACANT LOT
ZONING INFORMATION:
FRONT SETBACK: 9 FT.
REAR SETBACK: 0 FT.
LEFT SETBACK: 3 FT.
RIGHT SETBACK: 3 FT.
APN: 047-202-23
LOT 8, BLOCK 16, CITY OF NEWPORT BEACH, COUNTY OF ORANGE,
STATE OF CALIFORNIA
CODES:NBMC (NEWPORT BEACH MUNICIPAL CODE)
2019 CRC, 2019 CFC, 2019 CEC, AND 2019 CMC
CALGREEN AND 2019 CAL. ENERGY CODE
OCCUPANT LOAD 1 UNIT
OCCUPANCY CLASSIFICATION R-3/ U
OCCUPANCY SEPARATION (GARAGE)1-HR.
FLOOR & FLOOR-CEILING N/A.
TYPE OF CONSTRUCTION VB - SPRINKLERED
FIRE SPRINKLER YES
HEIGHT 3 - LEVELS
FLOOR AREA REF. 7/T-1.0
ALLOWABLE BLDG. ARE (PER CBC TBL. 503)N/A.
DIG ALERT:1.800.227.2600
SOUTHERN CALIFORNIA EDISON:1.714.895.0246
SOUTHERN CALIFORNIA GAS:1.800.427.2000
CITY WATER & SEWER:1.949.644.3011
PACIFIC BELL TELEPHONE:1.800.750.2355
CITY OF NEWPORT BEACH
PUBLIC WORKS DEPT.:1.949.644.3311
CITY OF NEWPORT BEACH PLANNING DEPT.:
GENERAL INFORMATION:1.949.644.3200
ZONING INFORMATION:1.949.644.3204
CITY OF NEWPORT BEACH BUILDING DEPT.:
GENERAL:1.949.644.3275
PERMITS:1.949.644.3288
INSPECTIONS:1.949.644.3255
NEWPORT BEACH FIRE DEPARTMENT:1.949.644.3106
ORANGE COUNTY HEALTH SERVICES:1.714.834.3882
1.A CAL-OSHA PERMIT IS REQUIRED FOR EXCAVATIONS DEEPER THAN 5' AND FOR SHORING AND UNDERPINNING. CONTRACTOR TO
PROVIDE A COPY OF OSHA PERMIT.
2. CONTRACTOR SHALL USE THE CITY STANDARD FORM '30-DAY NOTICE OF INTENT TO EXCAVATE' TO NOTIFY ADJACENT PROPERTY
OWNERS BY CERTIFIED MAIL 30-DAYS PRIOR TO STARTING EXCAVATION OR SHORING. CITY STANDARD FORM CAN BE OBTAINED AT:
HTTP://WWW.NEWPORTBEACHCA.GOV/HOME/SHOWDOCUMENT?ID=17395
1.REF. STRUCTURAL DRAWINGS FOR SPECIAL INSPECTIONS BY ENGINEER OF RECORD
2. HERS VERIFICATION REQUIRED, REF. ENERGY CALCULATIONS
1.
2.
3.
4.
5.
6.
7.
LANDSCAPE PLAN; BBQ; FIRE PIT; ACCESSORY STRUCTURES, MASONRY OR CONCRETE WALLS/FENCES; RETAINING WALLS OVER 4 FT.
HIGH FROM THE BOTTOM OF THE FOUNDATION TO THE TOP OF WALL; UNDER SEPARATE REVIEWS AND PERMITS (FOR H.O.A.
PURPOSES).
FENCES, PATIO COVERS AND OTHER FREESTANDING STRUCTURES REQUIRE SEPARATE REVIEWS AND PERMITS.
SUBMIT SOUND ATTENUATION DESIGN FOR HVAC EQUIPMENT PER ARI STD. 275. SOUND LEVEL NOT TO EXCEED 50dBA (55dBA WITH
TIMER, 65dBA WITH TIMER AND NEIGHBORS CONSENT). LOCATION OF MEASUREMENT TO BE AT ADJACENT PROPERTY PATIO OR
OPENING.
FIRE SPRINKLERS REQUIRED, CONTRACTOR TO SUBMIT FIRE SPRINKLER DRAWINGS FOR ARCHITECT'S APPROVAL PRIOR TO
SUBMITTING TO CITY. OBTAIN FIRE SPRINKLER PERMIT PRIOR TO CALLING FOR ROOF SHEATHING INSPECTION.
A NOTICE OF INTENT TO DEMOLISH SHALL BE SENT VIA CERTIFIED MAIL TO ADJACENT PROPERTY OWNER(S). SIGNED RETURNED
RECEIPT MUST BE PROVIDED TO THE BUILDING DIVISION AT THE TIME OF PERMIT ISSUANCE. DEMOLITION MAY COMMENCE 30 DAYS
AFTER THE DATE OF NOTIFICATION PER NEWPORT BEACH MUNICIPAL CODE SECTION 15.02.120.
PV SOLAR SYSTEM (MIN. 4.3KW DC) + 5 KWH BATTERY SYSTEM PER T-24
ELEVATOR
NOTE: DEFERRED SUBMITTALS TO BE REVIEWED BY PROJECT ARCHITECT OR ENGINEER OF RECORD AND CERTIFIED PRIOR TO
SUBMITTAL TO LOCAL AGENCY FOR REVIEW.
C.N.B. NOTE: BRANDON ARCHITECTS, INC. IS THE DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE OF THE PROJECT, RESPONSIBLE FOR
REVIEWING AND COORDINATING SUBMITTAL DOCUMENTS PREPARED BY OTHERS, INCLUDING PHASED AND DEFERRED SUBMITTAL
ITEMS, FOR COMPATIBILITY WITH THE DESIGN OF THE BUILDING. (NBMC 12.02.010)
THE SUBJECT PROPERTY IS LOCATED IN NEWPORT BEACH, CA IN THE AREA KNOWN AS THE BALBOA PENINSULA WITH BEACH FRONTAGE
ON WEST OCEAN FRONT. THE LOT IS APPROXIMATELY 30' WIDE BY 100' DEEP, IT IS ZONED R-2 (TWO-UNIT RESIDENTIAL) AND IS
APPROXIMATELY 3,075 S.F. THE CLIENT PROPOSES TO BUILD A NEW 3-STORY SINGLE FAMILY RESIDENCE OF APPROX. 3250 S.F. WITH
AN ATTACHED 2-CAR GARAGE AT 476 S.F. WITH ACCESS OFF THE ALLEY. THE PROGRAM INCLUDES BUT NOT LIMITED TO THE
FOLLOWING: (FIRST FLOOR) LARGE KITCHEN W/. THE EAT-IN ISLAND, GREAT ROOM, LOUNGE, DINING AREA, TWO FULL BATHS, LAUNDRY
AND A SAND ROOM. (SECOND FLOOR) INCLUDES A MASTER SUITE, MASTER BATH, A SECONDARY BEDROOM WITH AN ENSUITE. (THIRD
FLOOR) INCLUDES A BONUS ROOM, AND A POWDER BATH. AMPLE OUTDOOR SPACES PROVIDED IN THE FORM OF THE FIRST FLOOR
PATIO (OCEANFRONT), BALCONIES AND TWO VIEW DECKS ON THE THIRD FLOOR. THE PROJECT IS OF TRANSITIONAL DESIGN FEATURING
AMPLE INDOOR-OUTDOOR LIVING SPACES INTEGRATED WITH A MODERN 'OPEN' LIVING PLAN WITH LOTS OF GLAZING TO MAXIMIZE
OCEAN VIEWS AND THE EXTERIOR MATERIALS WILL BE OF RICH QUALITY AND HIGH DURABILITY WHICH CONSIST OF PRIMARILY
SMOOTH STUCCO WITH WOOD AND STEEL ACCENTS.
T-1.0 TITLE SHEET
TP-1 TOPOGRAPHIC SURVEY
C1 PRECISE GRADING PLAN
L-1 LANDSCAPE PLANTING PLAN
A-0.0 ARCHITECTURAL SITE PLAN
A-0.1 SLAB EDGE PLAN AND AREA PLANS
A-1.0 3D VIEWS
A-2.0 FIRST AND SECOND LEVEL FLOOR PLAN
A-2.1 THIRD LEVEL FLOOR PLAN
A-2.2 FIRST AND SECOND LEVEL DIMENSION PLAN
A-2.3 THIRD LEVEL DIMENSION PLAN
A-3.0 ROOF PLAN
A-4.0 EXTERIOR ELEVATIONS
A-4.1 EXTERIOR ELEVATIONS
A-5.0 BUILDING SECTIONS
NO. REVISION DATE
NEWPORT BEACH
W. BALBOA BLVD.
SITE
NEWPORT BAY 14TH ST.TOTALTOTAL
TOTALTOTAL
UNCOVEREDUNCOVERED
COMMENTSCOMMENTS
UNCOVEREDUNCOVERED
COVEREDCOVERED
COVEREDCOVERED
UNCOVEREDUNCOVERED
UNCOVEREDUNCOVERED
PARTIALLY COVEREDPARTIALLY COVERED
UNCOVEREDUNCOVERED
UNCOVEREDUNCOVERED
UNCOVEREDUNCOVERED
PA2022-067
PA2022-067
F.F.=12.50F.F.=11.33GARAGE13 9 A v e n i d a N a v a r r oSan Clemente, CA 926729 4 9 . 4 9 2 . 8 5 8 6www.toalengineering.comCIVIL ENGINEERINGL A N D S U R V E Y I N GSTORMWATER QUALITYPRELIMINARY PLANNOT FOR CONSTRUCTIONUTILITY NOTESDETAILBOTTOMLESS TRENCH DRAINDETAILTYPICAL DRAIN INLETDETAILTYPICAL SIDE YARD SWALEDETAILDOWNSPOUT CONNECTIONBENCHMARK NOTE:OCSBM 1E-124-14ELEV=7.660NAVD88 DATUM, 2015 ADJ.EASEMENT NOTE:ALL EASEMENTS SHOWN ON THIS TOPOGRAPHIC AND BOUNDARYSURVEY ARE PER A PRELIMINARY TITLE REPORT PREPARED BY CHICAGOTITLE COMPANY, ORDER NO. 58601908503-JFA DATED SEPTEMBER 26,2019 UNLESS NOTED OTHERWISE.5 ITEM 5 OF THE PRELIMINARY TITLE REPORT, AN EASEMENTFORUNDERGROUND LINES, CONDUITS, FIXTURES AND INCIDENTALPURPOSES RECORDED IN BOOK 10615, PAGE 826 O.R.BASIS OF BEARINGS NOTE:THE BASIS OF BEARINGS FOR THIS TOPOGRAPHIC AND BOUNDARYSURVEY IS THE CENTERLINE OF THE ALLEY, N 79°19'33" W AS SHOWN ONRSB 262/23-33.BOUNDARY NOTE:THE PLAT SHOWN HEREON IS PER CR 2020-3279 PREPARED BY MICHAELTORTOMASI, RCE 28328, AND FILED ON 11/24/2020. THIS OFFICE FOUND ALLCORNERS SET THEREFROM.LEGENDPA2022-067
LLLLLLLLLLLLLLLLLLLLLLLLLLLLL L L L
LLLLL
LAVANDULA SPP. LAVENDER (LOW WATER USE)
PLANT LEGEND
L
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED, ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL THEN BE HELD HARMLESS AND ABSOLVED OF ANY LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
03-22-2022
LANDSCAPE
PLANTING PLANOCEAN FRONT POOL HOUSESMITH 507 LLC
1616 W. OCEAN FRONT,
NEWPORT BEACH , CA 92663
CDP SUBMITTAL
1616 W. OCEAN FRONT, NEWPORT
BEACH , CA 92663
L-1
**0000-2021**
ELIZABETH HANNA
NO. REVISION DATE
PROJECT NORTHTRUE NORTH
1/4" = 1'-0"1PLANTING PLAN
LANDSCAPE NOTES:LANDSCAPE NOTES:
1. ENCOARCHMENT PERMIT REQ'D. FOR ANY WORK PROPOSED IN THE PUBLIC R.O.W.
2. IF APPLICABLE, REF. PRELIMINARY LANSCAPE PLAN, FOR ALL HARDSCAPE & PLANTING AREAS WITH REPECTIVE HEIGHTS
AND MATERIALS.
GENERAL MATERIAL SPECIFICATION:
1. GROUT CELLS WITH REINFORCED CEMENT PER ASTM C150. 1 PART PORTLAND CEMENT, 2 TO 3 PARTS LOOSE SAND, 2 PARTS COARSE AGGREGATE.
2. REINFORCING: FS = 20,000 PSI ASTM A615 GRADE 40.
3. MASONRY: FC = 1,500 PSI GRADE 'A' PER ASTM C150.
4. CONCRETE: FC = 3,500 PSI AT 28 DAYS CEMENT PER ASTM C150.
5. POUR ALL WALL FOOTINGS AGAINST NATURAL UNDISTURBED EARTH.
6. TELEPHONE LANDSCAPE ARCHITECT IF SITE CONDITIONS ARE NOT AS SHOWN.
PROJECT HARDSCAPE MATERIALS:
STONE SHOULD MATCH THE STONE USED ON THE HOUSE.
PAVING STONE SHALL BE SHADOW GRAY SANDSTONE/QUARTZITE.
ALL GROUT JOINTS SHALL BE PIGMENTED PER ARCH./G.C. APPROVAL.
ALL HARDSCAPE MATERIAL SHALL RECEIVE 6 MIL. VISQUEEN ON UNDER SIDE FOR WATERPROOF PROTECTION.
TOTAL LANDSCAPING AREA: 196.47 SQFT
**ALL PLANTS TO BE DROUGHT-TOLERANT NON-INVASIVE PLANT SPECIES. PLANT HEIGHT 42" MAX.
PA2022-067
UP
UP
UP
UPUP
DN
UP UP
ROOM TAGROOM NAME
?
1
10.00'SPOT ELEVATION
KEYNOTE TAG
REVISION TAG
PROPERTY LINE TAG90 00' 00"20.00'N E
FIREPIT - AS SELECTED TO BE LISTED AND APPROVED, VERIFY W/.
OWNER – PROVIDE POWER AND GAS AS REQUIRED – INSTALL AND
MAINTAIN CLEARANCES PER MFGR. AND SECTION 308 OF CFC
RECESSED MAIN SERVICE PANEL - 400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE
OF PANEL TO ANY OBSTRUCTION) – GC TO COORDINATE W/. UTILITY COMPANY
A/C CONDENSER / HEAT PUMP - TO BE IN COMPLIANCE OF SECTION 307.3 OF CPC AS
SELECTED, VERIFY W/. OWNER - SIZE TBD, SEE T-24 ENERGY REPORT FOR MORE INFO –
PROVIDE POWER AND SOUND DAMPENING PAD AS REQ ’D. – INSTALL AND MAINTAIN
REQUIRED CLEARANCES PER MFGR. INSTRUCTION
VERTICAL STORM DRAIN PIPE IN-WALL / OVERFLOW - MTL. PIPE PER
CHAPTER 11 OF CPC, SIZE PER TABLE 1103.1 (MIN. 2 ” DIA. PIPE & TYP. 3” DIA. PIPE) –
SEE CIVIL DWGS. FOR TERMINATION DTLS. ABV. OR BLW. GROUND. VERIFY ALL
TERMINATION POINTS, TYPE AND DETAILS W/. CIVIL PRIOR TO POURING THE CONCRETE
SLAB
OVERFLOW
DRAINLINE
UP
EXT. STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE ARTIFICIAL LIGHT
SOURCE AT THE TOP LANDING AND FOR STAIR TO THE BASEMENT AT BOTH TOP
AND BOTTOM LANDING (R303.8) - REF. DTL. 3/AD-1 -VERIFY TREADS DEPTH AND
RISERS HT. W/. CIVIL AND LANDSCAPE DWGS
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE
NEAREST 1/8" AND INTERIOR PARTITIONS ARE DIMENSIONED FROM FACE OF STRUCTURE TO FACE OF STRUCTURE (F.O.S.)
U.N.O. - CONTACT ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
GENERAL NOTE:
SEE SHEET A-3.0 FOR ROOF PLAN INFORMATION NOT SHOWN ON THIS SHEET (INCLUDING EAVE DETAILS AND PROJECTION
DISTANCES).
C.N.B. NOTES:
1. ISSUANCE OF A BUILDING PERMIT BY THE CITY OF NEWPORT BEACH DOES NOT RELIEVE APPLICANTS OF THE LEGAL
REQUIREMENTS TO OBSERVE COVENANTS, CONDITIONS AND RESTRICTIONS WHICH MAY BE RECORDED AGAINST THE PROPERTY
OR TO OBTAIN PLANS YOU SHOULD CONTACT YOUR COMMUNITY ASSOCIATIONS PRIOR TO COMMENCEMENT OF ANY
CONSTRUCTION AUTHORIZED BY THIS PERMIT.
2. PRIOR TO PERFORMING ANY WORK IN THE CITY RIGHT-OF-WAY AN ENCROACHMENT PERMIT MUST BE OBTAINED FROM THE
PUBLIC WORKS DEPARTMENT.
3. A CAL-OSHA PERMIT IS REQUIRED FOR EXCAVATIONS DEEPER THAN 5' AND FOR SHORING AND UNDERPINNING.
4. ELECTRICAL SERVICE TO BE UNDERGROUND FOR NEW CONSTRUCTION, REPLACEMENT BUILDING OR ADDITIONS TO AN
EXISTING BUILDING EXCEEDING 50% OF THE GROSS FLOOR AREA OF THE EXISTING BUILDING. (NBMC 12.32.015)
5. FIELD INSPECTOR TO REVIEW AND APPROVE UNDERGROUND ELEC. SERVICE REQUIREMENT PRIOR TO CONCRETE PLACEMENT.
6. EDISON COMPANY APPROVAL IS REQUIRED FOR METER LOCATION PRIOR TO INSTALLATION.
LANDSCAPE NOTES:
1. ENCROACHMENT PERMIT REQ'D. FOR ANY WORK PROPOSED IN THE PUBLIC R.O.W.
2. IF APPLICABLE, REF. PRELIMINARY LANDSCAPE PLANS, FOR ALL HARDSCAPE & PLANTING AREAS WITH RESPECTIVE HEIGHTS
AND MATERIALS.
POOL:
1. PROVIDE AN ALARM FOR DOORS AND WINDOWS WITH SILL HEIGHTS LESS THAN 60-INCHES ABV.F.F. OF THE DWELLING THAT
FORMS A PART OF THE POOL ENCLOSURE. THE ALARM SHALL BE LISTED AS A WATER HAZARD ENTRANCE ALARM IN
ACCORDANCE WITH UL 2017. THE DEACTIVATION SWITCH SHALL BE AT LEAST 60" ABOVE THE FLOOR IF THE RESIDENCE IS NOT
REQUIRED TO BE ACCESSIBLE. (CBC 3109 & ISPSC 305.4)
2. SUCTION OUTLETS SHALL BE DESIGNED AND INSTALLED WITH SUCTION ANTIENTRAPMENT GRATE IN ACCORDANCE WITH
ANSI/APSP-16 PER CBC 3109 SECTION (B) OF 115928. SUCTION ENTRAPMENT AVOIDANCE FOR POOL AND SPA SHALL BE PROVIDED IN ACCORDANCE WITH APSP-7 PER ISPSC SECTION 310.
3. PROVIDE POWER SAFETY COVER IN COMPLIANCE WITH ASTM F1346-91 FOR POOL & SPA (CBC 3109 SECTION (3) OF 115922 &
ISPSC 305).
4. POOL ENCLOSURE FENCE SHALL BE 60-INCHES MIN. ABV. FS/NG MEASURED ON THE SIDE THAT FACES AWAY FROM
SWIMMING POOL W/. MAX VERTICAL CLEARANCE OF 2-INCHES BETWEEN FS/NG AND BOTTOM OF THE FENCE/BARRIER
MEASURED ON THE SIDE OF FENCE THAT FACES AWAY FROM SWIMMING POOL. OPENING, GAP, AND VOID IN ENCLOSURE FENCE
OR GATE SHALL NOT ALLOW THE PASSAGE OF 4-INCHES DIAMETER SPHERE OR LARGER. OUTSIDE SURFACE (FACING AWAY
FROM SWIMMING POOL) OF THE POOL ENCLOSURE INCLUDING THE GATE TO BE FREE OF PROTRUSIONS, CAVITIES, OR OTHER
PHYSICAL CHARACTERISTICS THAT WOULD SERVE AS HANDHOLDS OR FOOTHOLDS WHICH COULD ENABLE A CHILD FIVE YEARS
OLD OR YOUNGER TO CLIMB OVER. (CBC 3109 & ISPSC 305)
ENTRY
ELEV.
2-CAR GARAGE
12.50' F.F.
11.33' F.F.12.50' F.F.
11
PATIO
11 1
11.33' F.F.F.O.F.3' - 0"3' - 2"F.O.F.4' - 6 1/8"4' - 8 1/8"F.O.F.3' - 1"3' - 2"F.O.F.4' - 6 1/2"4' - 8 1/2"F.O.F.
1' - 0"
1' - 2"F.O.F.3' - 7"F.O.F.3' - 8"3' - 9"F.O.F.8' - 9"8' - 10"F.O.F.3' - 0"3' - 2"F.O.F.
14' - 8"
14' - 10"
2
2
22
3
3
3
STORAGE
GATEGATE
GATEGATEGATEALLEYLOT 9
EXIISTING RESIDENCE
(NOT A PART)
LOT 7
EXIISTING RESIDENCE
(NOT A PART)OCEAN FRONT AVENUE(BEACH ACCESS)PLANTED AREA
APN: 047-202-23
LOT 8
PROPOSED 3-STORY SINGLE FAMILY RESIDENCE WITH ATTACHED 2-CAR
GARAGE
PLANTED AREA
SLOPE PER CIVIL
TRASH AREA
4
4
5
5
5
6
7
7
7
7
8
9
9 CLR.20' - 5"CLR.
19' - 0"
FIREPIT
OUTDOOR DINING
BENCH SEATING
P.L. TO STREET C.L.
10' - 0"S.Y.S.B.3' - 0"S.Y.S.B.3' - 0"F.Y.S.B.
9' - 0"79° 19' 51"29.98'SE10° 40' 09"102.44'SW79° 19' 51"29.98'NW10° 40' 09"102.44'NE
DOUBLE SHOWER CLR.3' - 3 1/4"1' - 0"1' - 0"CLR.3' - 4 1/4"CLR.
36" MIN.TYP.
10 1/2"
1' - 0"CLR.3' - 0"10
11
16.00' T.O.W.
1213
14
12
15
16
14
5
17 17
17 17
CLR.2' - 10"REF. CIVIL FOR T.O.S
REF. CIVIL FOR T.O.SREF. CIVIL FOR T.O.S
18
F.O.F.7' - 1 3/8"F.O.F.7' - 0 1/8"F.O.F.9' - 0 1/4"16.00' T.O.W.
19
1919
20
21
21 F.O.F.4' - 10 1/2"F.O.F.2' - 9 7/8"F.O.F.2' - 9 5/8"5
BALCONY OVERHANG
3' - 0"
86' - 5 1/4"
PT#2: 14.83' F.S.
PT#1: 10.09' F.S.
PT#4: 10.08' F.S.
PT#3: 12.82' F.S.
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED, ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL THEN BE HELD HARMLESS AND ABSOLVED OF ANY LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
SITE PLAN NOTESA
ANNOTATION LEGENDB
KEYNOTESC
BRANDON ARCHITECTS
03-22-2022
ARCHITECTURAL
SITE PLANOCEAN FRONT POOL HOUSESMITH 507 LLC
1616 W. OCEAN FRONT,
NEWPORT BEACH , CA 92663
CDP SUBMITTAL
1616 W. OCEAN FRONT, NEWPORT
BEACH , CA 92663
A-0.0
**0000-2021**
ELIZABETH HANNA
1 (E.) PROPERTY LINE WALL - PROTECT IN PLACE
2 PLANTED AREA - COORDINATE WITH LANDSCAPE DESIGNER
3 STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL ON TREAD RUNS OF
NOT LESS THAN 1 FOOT CANDLE (CBC 1205.4) REF. DTL. 3/AD-1
4 LINE OF SECOND FLOOR ABOVE
5 OUTLINE OF REMOVED STRUCTURE
6 CENTERLINE/FLOWLINE OF ALLEY
7 PROPERTY LINE
8 FRONT YARD SETBACK
9 SIDE YARD SETBACK
10 RECESSED MAIN SERVICE PANEL, 400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE OF PANEL TOANY OBSTRUCTION)
11 WATER HEATER - TANK-LESS (ON DEMAND) WALL-MOUNT +48" MIN., 'TAKAGI' OR EQUIV. - VERIFY
SIZE REQ'D. W/. MFG. (PROVIDE ADEQUATE N.G. CONN.)
12 (E.) CABLE TV JUNCTION BOX
13 (E.) TELEPHONE BOX LOCATION - (REF. SURVEY & CIVIL DWGS.)
14 (E.) WATER METER LOCATION - (REF. SURVEY & CIVIL DWGS.)
15 (E.) SEWER C.O. LOCATION - (REF. SURVEY & CIVIL DWGS.)
16 (E.) ELECTRIC BOX LOCATION - (REF. SURVEY & CIVIL DWGS.)
17 (N.) CONCRETE STEPS ON GRADE - REF. CIVIL DWGS.
18 TRASH LOCATION - SCREEN FROM STREET AS NEEDED
19 (N.) WOOD GATE - AS SELECTED. PAINT TO MATCH WOOD PANEL SIDING SCREEN. REF. MATERIAL
SCHEDULE SHT A-4.0
20 FIREPIT - PROVIDE GAS STUB-OUT, REF. LAND. DWGS., VERIFY W/. OWNER
21 STRUCT. STEEL COLUMN - REF. STRUCT. DWGS. & PROVIDE SHOP DWGS. FOR ARCH. & ENGINEER
APPV. PRIOR TO FAB.
NO. REVISION DATE
PROJECT NORTHTRUE NORTH
1/4" = 1'-0"1 ARCHITECTURAL SITE PLAN
3/16" = 1'-0"2 GRADE PLANE
PLANE GRADE EXHIBIT
PT. #1 10.09' F.S.
PT. #2 14.83' F.S.
PT. #3 12.82' F.S.
PT. #4 10.08' F.S.
TOTAL: 47.82' / 4 = 11.95'
AVERAGE SLOPE
PT. #1(10.08' F.S.) - PT. #2
(14.83' F.S.) / 86.44'
TOTAL: 5.5% SLOPE
PA2022-067
DN
DN
DN
ROOM TAGROOM NAME
?
1
10.00'SPOT ELEVATION
KEYNOTE TAG
REVISION TAG
STRUCTURAL STEEL COLUMN - PER STRUCT., REF. STRUCT. DWGS. - PAINT AND SEAL
AS REQUIRED - ARCH. TO APPV. PAINT COLOR FOR EXPOSED STEEL COLUMNS
WALL FRAMING - REF. A-2.0 DIMENSION PLANS FOR SIZING AND DIMENSIONS
CONCRETE WALL - 12" REINFORCED CAST IN PLACE CONCRETE WALL TYP. U.N.O. PER
STRUCT., REF. STRUCT. DWGS. - FOR BASEMENT/RETAINING CONCRETE WALL PROVIDE
WATERPROOFING OR DAMPROOFING AND DRAINAGE AS REQUIRED PER SECTION R406.1 &
R406.2. REF/ SOILS REPORT, WATERPROOFING & DAMPROOFING NOTES ON SHEET T-1.1 -
EXPOSED SURFACES TO HAVE TROWELED SMOOTH FINISH WITH A LIGHT GRAY COLOR,
PROVIDE SAMPLE FOR ARCH. APPROVAL
STRUCTURAL WOOD POST/COLUMN - PER STRUCT., REF. STRUCT. DWGS. - PAINT, STAIN
AND SEAL AS REQUIRED - ARCH. TO APPV. PAINT COLOR FOR EXPOSED WOOD
POST/COLUMN, IF TO BE STAINED PROVIDE STAINED SAMPLE FOR ARCH. APPROVAL
SLAB/FRAMING DEPRESSION - SEE STRUCT. DWGS. FOR THE RECESSION DETAILS - FOR
RECESSION SPECIFIC TO EQUIPMENT OR ASSEMBLY VERIFY THE REQUIRED RECESSION
W/. MFGR. OR FABRICATOR - SHOWER RECESSION TO BE VERIFIED W/. I.D.
VERTICAL STORM DRAIN PIPE IN-WALL / OVERFLOW - MTL. PIPE PER
CHAPTER 11 OF CPC, SIZE PER TABLE 1103.1 (MIN. 2 ” DIA. PIPE & TYP. 3” DIA. PIPE) –
SEE CIVIL DWGS. FOR TERMINATION DTLS. ABV. OR BLW. GROUND. VERIFY ALL
TERMINATION POINTS, TYPE AND DETAILS W/. CIVIL PRIOR TO POURING THE CONCRETE
SLAB
OVERFLOW
DRAINLINE
NOTE:
GENERAL CONTRACTOR TO PROVIDE SHOP DRAWINGS CONSISTENT WITH THE CONSTRUCTION DOCUMENTS. GENERAL
CONTRACTOR TO REVIEW AND APPROVE ALL FINAL SHOP DRAWINGS PRIOR TO FABRICATION & POURING.
ARCHITECT & STRUCTURAL ENGINEER TO REVIEW SHOP DWGS. FOR DESIGN CONFORMITY TO THE CONSTRUCTION DOCUMENTS
PRIOR TO FABRICATION & POURING.
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE
NEAREST 1/8" - CONTACT ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
WATERPROOFING AND DAMPPROOFING NOTES:
R406.1 CONCRETE AND MASONRY FOUNDATION DAMPPROOFING
EXCEPT WHERE REQUIRED BY SECTION R406.2 TO BE WATERPROOFED, FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE
INTERIOR SPACES AND FLOORS BELOW GRADE SHALL BE DAMPPROOFED FROM THE HIGHER OF (A) THE TOP OF THE FOOTING OR
(B) 6 INCHES (152 MM) BELOW THE TOP OF THE BASEMENT FLOOR, TO THE FINISHED GRADE. MASONRY WALLS SHALL HAVE NOT
LESS THAN 3/8-INCH (9.5 MM) PORTLAND CEMENT PARGING APPLIED TO THE EXTERIOR OF THE WALL. THE PARGING SHALL BE
DAMPPROOFED IN ACCORDANCE WITH ONE OF THE FOLLOWING:
1. BITUMINOUS COATING.
2. THREE POUNDS PER SQUARE YARD (1.63 KG/M2) OF ACRYLIC MODIFIED CEMENT.
3. ONE-EIGHTH-INCH (3.2 MM) COAT OF SURFACE-BONDING CEMENT COMPLYING WITH ASTM C887.
4. ANY MATERIAL PERMITTED FOR WATERPROOFING IN SECTION R406.2.
5. OTHER APPROVED METHODS OR MATERIALS.
EXCEPTION: PARGING OF UNIT MASONRY WALLS IS NOT REQUIRED WHERE A MATERIAL IS APPROVED FOR DIRECT APPLICATION
TO THE MASONRY.CONCRETE WALLS SHALL BE DAMPPROOFED BY APPLYING ANY ONE OF THE LISTED DAMPPROOFING
MATERIALS OR ANY ONE OF THE WATERPROOFING MATERIALS LISTED IN SECTION R406.2 TO THE EXTERIOR OF THE WALL.
R406.2 CONCRETE AND MASONRY FOUNDATION WATERPROOFING
IN AREAS WHERE A HIGH WATER TABLE OR OTHER SEVERE SOIL-WATER CONDITIONS ARE KNOWN TO EXIST, EXTERIOR
FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE INTERIOR SPACES AND FLOORS BELOW GRADE SHALL BE
WATERPROOFED FROM THE HIGHER OF (A) THE TOP OF THE FOOTING OR (B) 6 INCHES (152 MM) BELOW THE TOP OF THE
BASEMENT FLOOR, TO THE FINISHED GRADE. WALLS SHALL BE WATERPROOFED IN ACCORDANCE WITH ONE OF THE FOLLOWING:
1. TWO-PLY HOT-MOPPED FELTS.
2. FIFTY-FIVE-POUND (25 KG) ROLL ROOFING.
3. SIX-MIL (0.15 MM) POLYVINYL CHLORIDE.
4. SIX-MIL (0.15 MM) POLYETHYLENE.
5. FORTY-MIL (1 MM) POLYMER-MODIFIED ASPHALT.
6. SIXTY-MIL (1.5 MM) FLEXIBLE POLYMER CEMENT.
7. ONE-EIGHTH-INCH (3 MM) CEMENT-BASED, FIBER-REINFORCED, WATERPROOF COATING.
8. SIXTY-MIL (1.5 MM) SOLVENT-FREE LIQUID-APPLIED SYNTHETIC RUBBER.
ALL JOINTS IN MEMBRANE WATERPROOFING SHALL BE LAPPED AND SEALED WITH AN ADHESIVE COMPATIBLE WITH THE
MEMBRANE.
EXCEPTION: ORGANIC-SOLVENT-BASED PRODUCTS SUCH AS HYDROCARBONS, CHLORINATED HYDROCARBONS, KETONES AND
ESTERS SHALL NOT BE USED FOR ICF WALLS WITH EXPANDED POLYSTYRENE FORM MATERIAL. USE OF PLASTIC ROOFING
CEMENTS, ACRYLIC COATINGS, LATEX COATINGS, MORTARS AND PARGINGS TO SEAL ICF WALLS IS PERMITTED. COLD-SETTING
ASPHALT OR HOT ASPHALT SHALL CONFORM TO TYPE C OF ASTM D449. HOT ASPHALT SHALL BE APPLIED AT A TEMPERATURE OF
LESS THAN 200°F (93°C).
SLAB ON GRADE NOTE:
PROVIDE BASE PER R506.2.2 AND VAPOR RETARDER PER R506.2.3 W/. CAPILLARY BREAK
12.50' F.F.
11.33' F.F.
11.33' F.F.
SLOPE PER CIVIL
REF. CIVIL FOR T.O.S
REF. CIVIL FOR T.O.S
LOUNGEKITCHEN
DINING
GREAT ROOMFOYER
GIRL'S POOL BATH
2-CAR GARAGE
SAND ROOM
BOY'S POOL BATH
ELEV.
STAIRS
ENTRY1' - 0 7/8"21' - 6"1' - 0 7/8"35' - 11"17' - 6 1/2"7' - 0 3/4"6' - 2 1/2"19' - 8 1/2"
REF. CIVIL FOR T.O.S
14' - 10"86' - 5 1/4"1' - 2"3' - 9"21' - 6 1/4"4' - 8 1/2"1' - 5 5/8"F.O.18' - 6"1' - 6 5/8"35' - 11"13' - 0 3/4"37' - 5 1/2"
14' - 10"86' - 5 1/4"1' - 2"
SLAB DEPRESSION FOR
FIREPLACE VERIFY W/. G.C.,
MFGR., AND STRUCT. DWGS.
SLAB DEPRESSION
FOR FIREPLACE VERIFY
W/. G.C., MFGR., AND
STRUCT. DWGS.
SLAB DEPRESSION FOR
SHOWER VERIFY W/. G.C.
AND STRUCT. DWGS.
SLAB DEPRESSION FOR
SHOWER VERIFY W/. G.C.
AND STRUCT. DWGS.
SLAB DEPRESSION
FOR SLIDER DOOR
VERIFY W/. G.C. AND
STRUCT. DWGS.3' - 2"23' - 7 3/4"3' - 2"F.V.2' - 8 5/8" 6"F.V.4' - 1 1/2"2' - 1 1/2"8' - 2 7/8"5' - 0 3/4"F.V.5' - 7 1/2"6"F.V.
8"6' - 1 3/8"
F.V.
5' - 7 1/8"23' - 6 1/2"12' - 4"8 3/4"6"
F.V.
4' - 7 1/4"12' - 7 1/4"19' - 0 5/8"8 3/8"
V.F.
3' - 6 1/8"5' - 8"6' - 6 3/4"V.F.7' - 9 3/8"3' - 7 5/8"1
1' - 10 1/8"
F.O.
8' - 0"9' - 10 1/2"
FD
FD
FD 2
1378 SF
FIRST FLOOR LIVING
476 SF
2-CAR GARAGE
397 SF
PARTIALLY COVERED
PATIO
101 SF
COVERED FRONT ENTRY48 SF
PLANTED
8 SF
PLANTED
663 SF
SECOND FLOOR LIVING
84 SF
COVERED BALCONY
158 SF
2ND FLOOR BALCONY
223 SF
COVERED LOUNGE DECK 261 SF
DECK
54 SF
MECH.
1042 SF
POOL AREA
246 SF
THIRD FLOOR LIVING
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED, ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL THEN BE HELD HARMLESS AND ABSOLVED OF ANY LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
ANNOTATION LEGENDB
SLAB EDGE NOTESA
KEYNOTE LEGENDC
03-22-2022
SLAB EDGE PLAN
AND AREA PLANSOCEAN FRONT POOL HOUSESMITH 507 LLC
1616 W. OCEAN FRONT,
NEWPORT BEACH , CA 92663
CDP SUBMITTAL
1616 W. OCEAN FRONT, NEWPORT
BEACH , CA 92663
A-0.1
**0000-2021**
ELIZABETH HANNA
1 RECESSED MAIN SERVICE PANEL, 400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION)
2 PROVIDE FLOOR DRAIN IN LAUNDRY ROOM
NO. REVISION DATE
1/4" = 1'-0"1SLAB EDGE PLAN
1/8" = 1'-0"2FIRST LEVEL AREA PLAN
1/8" = 1'-0"3SECOND LEVEL AREA PLAN
1/8" = 1'-0"4THIRD LEVEL AREA PLAN
TOTAL BUILDING AREA SCHEDULE
NAMEAREA
LIVING
THIRD FLOOR LIVING246 SF
SECOND FLOOR LIVING663 SF
FIRST FLOOR LIVING1378 SF
LIVING2287 SF
GARAGE
2-CAR GARAGE476 SF
GARAGE476 SF
GRAND TOTAL2763 SF
TOTALTOTAL
TOTALTOTAL
FIRST FLOOR AREA SCHEDULE
NAME AREA
Area 0 SF
0 SF
GARAGE
2-CAR GARAGE 476 SF
476 SF
LIVING
FIRST FLOOR LIVING 1378 SF
1378 SF
OUTDOOR
FRONT ENTRY 101 SF
PATIO 397 SF
PLANTED 56 SF
554 SF
GRAND TOTAL 2408 SF
SECOND FLOOR AREA SCHEDULE
NAME AREA
LIVING
SECOND FLOOR LIVING 663 SF
663 SF
OUTDOOR
2ND FLOOR BALCONY 158 SF
BALCONY 84 SF
242 SF
GRAND TOTAL 906 SF
TOTAL OUTDOOR
TOTAL LIVING
TOTAL GARAGE
TOTAL OUTDOOR
TOTAL LIVING
THIRD FLOOR AREA SCHEDULE
NAME AREA
LIVING
THIRD FLOOR LIVING 246 SF
246 SF
OUTDOOR
COVERED LOUNGE DECK 223 SF
DECK 261 SF
MECH.54 SF
POOL AREA 1042 SF
1579 SF
GRAND TOTAL 1826 SF
TOTAL OUTDOOR
TOTAL LIVING
PA2022-067
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED, ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL THEN BE HELD HARMLESS AND ABSOLVED OF ANY LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
03-22-2022
3D VIEWSOCEAN FRONT POOL HOUSESMITH 507 LLC
1616 W. OCEAN FRONT,
NEWPORT BEACH , CA 92663
CDP SUBMITTAL
1616 W. OCEAN FRONT, NEWPORT
BEACH , CA 92663
A-1.0
**0000-2021**
ELIZABETH HANNA
NO. REVISION DATE
1AXONOMETRIC - NW2 AXONOMETRIC - NE
3AXONOMETRIC - SW4 AXONOMETRIC - SE
PA2022-067
UP
DNUP
UP
UP
UP
UP
DN
A-4.1
A-4.0
A-4.11
A-4.0
2
2
1
1
A-5.0
1
A-5.0
2
A-5.0
2
A-5.0
MASTER SUITE
BATH #2
MASTER BATH
ELEV.
STAIRS
BEDROOM #2
W/C.
LINEN
SHOWER
SEAT
TV ABV.
POOL STRUCTURE BALCONY
EXT.
MECH.
SHOWER
SEAT(OPEN TO BELOW)BUILT-IN CL.BUILT-IN CL.S.Y.S.B.3' - 0"S.Y.S.B.3' - 0"F.Y.S.B.
9' - 0"TYP.11"TYP.
10 1/2"CLR.15" MIN.2' - 9"
TYP.
11"CLR.3' - 0 3/4"R @ 0' - 7 1/2"16
R @0' - 7"8
R @0' - 7 1/2"20
R @ 0' - 7 3/8"16CLR.5' - 0 1/4"CLR.
4' - 6"
2% MIN.CL
R
.
3
0
"
M
I
N
.
CLR.
30" MIN.
1
1
2
3
3
EAVE OVERHANG
2' - 11"
4
4
4
4
4
44
44
9
9
8
10
1011
11 1616CLR.3' - 5"18
18
18
CLR.
3' - 6"
DNDN
19
20
1919
21
16
3
18
13
13
15
18
1617
15
12
14
19
20
17
14
17.1
14.1
4
4
21.09' F.F.
23.76' F.F.
EXTERIOR HALLWAY
CLR.2' - 10"13
13
13
TYP.
11"CLR.3' - 0 1/4"18
BALCONY
ROOM TAGROOM NAME
1
A-5.0
1 1
?
1
1
A-4.0
1
1 1
1
ELEVATION / SECTION INDICATOR
AD-1.0
1 CALL-OUT TAG
10.00'SPOT ELEVATION
KEYNOTE TAG
REVISION TAG
DOOR / WINDOW / WINDOW WALL TAG
FIRE RATED CEILING ASS'Y - REF. DTLS. 7/AD-1.0
1-HR RATED INT CONDITION - REF. DTLS. 7/AD-1.0
1-HR RATED EXT CONDITION - REF. DTLS. 7/AD-1.0
STRUCTURAL STEEL COLUMN PER STRUCT., REF. STRUTC.
DWGS, - PAINT AND SEAL AS REQUIRED – ARCH. TO APPV.
COLOR FOR EXPOSED STEEL COLUMNS
STRUCTURAL WOOD POST/COLUMN COLUMN - PER STRUCT., REF. STRUTC. DWGS, -
PAINT, STAIN AND SEAL AS REQUIRED – ARCH. TO APPV. PAINT COLOR FOR EXPOSED
WOOD POST/COLUMN, IF TO BE STAINED PROVIDE STAINED SAMPLE FOR ARCH,
APPROVAL
DOORS - AS SPECIFIED, SEE WINDOW SCHEDULE AND GENERAL NOTES ON SHEET A-7.0 -
SHGC & U-FCTOR PER T-24 ENERGY REPORT – SEE SHEET AD-2.0 FOR JAMB, HEAD AND
THRESHOLD DETAILS, PROVIDE FLASHING AND WATERPROOFING AT DOOR OPENING PER
THE DOOR MFGR. INSTRUCTION AND/OR FLASHING MFGR. INSTRUCTION PER SECTIONS
R609.1 & R703.4 OF CRC
WINDOW - AS SPECIFIED, SEE WINDOW SCHEDULE AND GENERAL NOTES ON
SHEET A-7.0 - SHGC & U-FCTOR PER T-24 ENERGY REPORT – SEE SHEET
AD-2.0 FOR JAMB, HEAD AND SILL DETAILS, PROVIDE FLASHING AND
WATERPROOFING AT WINDOW OPENING PER THE WINDOW MFGR.
INSTRUCTION AND/OR FLASHING MFGR. INSTRUCTION PER SECTIONS R609.1
& R703.4 OF CRC
KITCHEN RANGE W/. EXHAUST HOOD - AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
PROVIDE POWER AND GAS AS REQUIRED - 30 ” MIN. VERTICAL CLEARANCE TO ANY
COMBUSTIBLE MATERIAL ABV. COOKING TOP (CMC 920.3.2) –EXHAUST HOOD TO HAVE
EXHAUST RATE OF MIN. 100 CFM AND VENT TO OUTDOOR , HOOD DUCTS TO BE OF
METAL WITH SMOOTH INTERIOR FINISH PER SECTION 504.3 OF CMC
KITCHEN/BAR SINK - AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER – SINK TO COMPLY
W/. REQUIREMENT OF SECTION 420.0 OF CPC AND HAVE A MAX FLOW RATE OF 1.8 GPM
@ 60 PSI PER SECTION 4.303.1 OF CALGREEN – TRAP AND VENT FOR ISLAND SINK AND
SIMILAR EQUIPMENT SHALL BE PER SECTION 909.0 OF CPC
VANITY SINK - AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
LAVATORY TO HAVE 24” MIN. CLEAR SPACE IN FRONT OF IT.(CPC 402.5)
W/. MAXIMUM FLOW RATE OF 1.2 GPM @ 60 PSI AND MIN. FLOW RATE OF
0.8 GPM @ 20 PSI PER SECTION 4.303.1 OF CALGREEN
WASHER (W) / DRYER (D) / STACKED (W/D) - AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER – PROVIDE POWER , GAS, WATER SUPPLY & DRAINAGE AS REQUIRED - THE
CLOTHES DRYERS VENT SHALL BE OF A RIGID METALLIC MATERIAL AND HAVE A BACKDRAFT DAMPER (CMC 504.4) AND SHALL NOT EXCEED 14-FEET IN OVERALL LENGTH
WITH MAX. OF TWO (2) 90-DEGREE ELBOW, SUBTRACT 2-FEET FOR EACH ADDITIONAL 90-
DEGREE ELBOW. SEE WASHER & DRYER NOTES, REF. T-1.1.
REFRIGERATOR (REF) / FREEZER (FRZ) - AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER – PROVIDE POWER AND WATER SUPPLY AS REQUIRED
BUILT-IN APPLIANCE / DISHWASHER (DW) / TRASH COMPACTOR (TR) - AS SELECTED PER
I.D., VERIFY W/. I.D. & OWNER – PROVIDE POWER , WATER SUPPLY & DRAINAGE PIPE AS
REQUIRED
TOILET - WATER CLOSET SHALL BE IN COMPLIANCE OF SECTION 411.0 OF CPC AND HAS
MAX EFFECTIVE FLUSH RATE OF 1.28 GAL. PER FLUSH (CPC 411.2). WATER CLOSETS
CLR. TO BE 24” IN FRONT AND 15” FROM ITS CENTER TO ANY SIDE WALL OR
OBSTRUCTION. (CPC 402.5 & CRC R307) – REF. CALGREEN NOTES ON T SHTS. FOR MAX
FLOW RATE
CASEWORK, TALL CABINET - AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER
CASEWORK, BASE CABINET W/. COUNTERTOP - AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER
CASEWORK, UPPER CABINET/SHELVES - AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER
BUILT-IN CLOSET - AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER
FIREPLACE - FACTORY-BUILT DIRECT VENT GAS FIREPLACE W/. SEALED COMBUSTION
(CALGREEN 4.503) - FACTORY-BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR
COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING
AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. (CRC R1004.1)
ELEVATOR - PRIVATE RESIDENCE ELEVATOR IN COMPLIANCE W/. ASME A17.1/CSA B44
AS SELECTED PER PLANS, VERIFY W/. OWNER – PROVIDE POWER AS REQ'D. (CRC 321.1)
A/C CONDENSER / HEAT PUMP - TO BE IN COMPLIANCE OF SECTION 307.3 OF CPC AS
SELECTED, VERIFY W/. OWNER - SIZE TBD, SEE T-24 ENERGY REPORT FOR MORE INFO –
PROVIDE POWER AND SOUND DAMPENING PAD AS REQ ’D. – INSTALL AND MAINTAIN
REQUIRED CLEARANCES PER MFGR. INSTRUCTION
FAU - PROVIDE GAS S.O., POWER, AND VENTING AS REQ'D. BY MFG'R. – INSTALL PER
MFGR. INSTRUCTION
ROOF/DECK DRAIN - PER CHAPTER 11 OF CPC - SIZE THE DRAIN AND PIPING PER TABLE
1103.1 AND 1103.2 OF CPC – ROOF DRAIN SHALL HAVE DOMED STRAINER (CPC 1102.2) –
REF. DETAIL 11/AD-1.0
OVERFLOW OR EMERGENCY DRAIN - PER CHAPTER 11 OF CPC - COPPER OR EQ., INSTALL
PER MFGR. INSTRUC., SLOPED TOWARD IN-WALL DRAIN INLETS – SLOPE AND SIZE PER
TABLE 1103.3 OF CPC – REF. DTL. 11/AD-1.0
UP
20R@7 1/2"
STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL OF NOT
LESS THAN 1 FOOT CANDLE AS MEASURED AT THE CENTER OF TREADS AND
LANDING WITH ARTIFICIAL LIGHTING (R303.7) - REF. DTL. 3/AD-1
ELEVATOR - PRIVATE RESIDENCE ELEVATOR IN COMPLIANCE W/. ASME A17.1/CSA B44
AS SELECTED PER PLANS, VERIFY W/. OWNER – PROVIDE POWER AS REQUIRED (CRC
R321.1)
A-4.11
A-4.01
1
A-5.0
1
A-5.0
2
A-5.0
2
A-5.0
A-4.0
2
A-4.1
2
LOUNGE
KITCHEN
DINING
GREAT ROOM
FOYER
GIRL'S POOL BATH
2-CAR GARAGE
SAND ROOMBOY'S POOL BATH
ELEV.
STAIRS
ENTRY
CLR.5' - 6 1/4"CLR.
4' - 6"
LOCKERS
LOCKERS
SHOWER
SEAT
BENCH
BUILT-INS
R.
S.DW.TRASH
PANTRY
EAT-IN ISLAND
FP.TV ABV.
STORAGE
SHOWER SEATWET BARSTORAGE
DRIPGATELINE OF FLOOR ABV.GOLF CART PARKINGSTORAGEDOUBLE SHOWER
(OPEN TO ABV.)CLR.20' - 5"CLR.
19' - 0"
CLR.
3' - 6"
11.33' F.F.12.50' F.F.S.Y.S.B.3' - 0"S.Y.S.B.3' - 0"F.Y.S.B.
9' - 0"TYP.11"CLR.
3' - 6"CLR.4' - 6"1' - 0"
1' - 0"4' - 4 3/4"LINE OF FLOOR ABV.
LINE OF FLOOR ABV.
NOTE: PROVIDE MIN. (1) LAYER 5/8"
MOLD TOUGH VHI FIRECODE 'X' BD.
TO INSIDE FACE OF ALL GARAGE
WALLS. FD
FLOOR DRAIN SLOPE PER CIVIL
CLR.
30" MIN.
CLR.
30" MIN.
GATE
1
1
2
3
34
4
5
6
7
8
9
9
10
1011
1111
12
13
14
15
15
R @0' - 7 1/2"20
TYP.
10 1/2"
1718
181920
21
6
5
4
10
11
121
111012
5
3
2
3
89
97
8
4
6
7
9.1
8.1
BALCONY OVERHANG
3' - 0"
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED, ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL THEN BE HELD HARMLESS AND ABSOLVED OF ANY LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
KEYNOTESB
ANNOTATION LEGENDA
BRANDON ARCHITECTS
03-22-2022
FIRST AND SECOND
LEVEL FLOOR PLANOCEAN FRONT POOL HOUSESMITH 507 LLC
1616 W. OCEAN FRONT,
NEWPORT BEACH , CA 92663
CDP SUBMITTAL
1616 W. OCEAN FRONT, NEWPORT
BEACH , CA 92663
A-2.0
**0000-2021**
ELIZABETH HANNA
1/4" = 1'-0"2SECOND LEVEL FLOOR PLAN
1 PROPERTY LINE
2 FRONT YARD SETBACK
3 SIDE YARD SETBACK
4 STRUCT. STEEL COLUMN - REF. STRUCT. DWGS. & PROVIDE SHOP DWGS. FOR ARCH. & ENGINEER APPV. PRIOR TO FAB.
5 WATER HEATER - TANK-LESS (ON DEMAND) WALL-MOUNT +48" MIN., 'TAKAGI' OR EQUIV. - VERIFY SIZE REQ'D. W/. MFG.
(PROVIDE ADEQUATE N.G. CONN.)
6 DEPRESSED SLAB/STRUCTURE FOR FIREPLACE - COORD. WITH MFG'R. & GENERAL CONTRACTOR, REF. STRUCT. DWGS.
7 DEPRESSED SLAB FOR ELEVATOR - 12". COORD. WITH ELEVATOR MFG. & G.C., REF. STRUCT. DRAWINGS
8 DEPRESSED SLAB FOR SLIDING/POCKET DOORS - COORD. WITH DOOR MFG. & GENERAL CONTRACTOR.
9 DEPRESS STRUCTURE FOR FLUSH SHOWER CONDITION - COORD. WITH I.D. & GENERAL CONTRACTOR, REF. STRUCT. DWGS.
10 SHOWER - PROVIDE TILE W/. CEMENT BACKING MIN. 72" HIGH (R307.2)
11 CUSTOM SHOWER SEAT PER I.D.
12 FIREPLACE - PREFABRICATED, GAS ONLY, 'ISOKERN,' ICC# ESR-2316 [REF. DTL. 22/AD-1] (FACTORY BUILT FIREPLACES,
CHIMNEYS AND ALL OF THEIR COMPONENTS SHALL BE LISTED AN INSTALLED IN ACCORDANCE W/. THEIR LISTING AND MFG'R.
INSTALLATION INSTRUCTIONS. GASEOUS FUEL BURNING PAN MUST BE PERMANENTLY ANCHORED TO THE FIREBOX.
FIREPLACE MUST COMPLY W/. THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES.)"
13 WOOD PANEL SIDING SCREEN - EXT. GRADE MDX, PAINT AS SEL., REF. MATERIAL SCHEDULE SHT. A-4.0
14 GARAGE DOOR - RATED, 1-3/8" SOLID CORE, SELF-CLOSING AND SELF-LATCHING. REF. DOOR SCHEDULE. 7 3/4" STEP AT IN
SWING DOORS (R311.3.1.)
15 1-1/2" MAX. STEP AT OUT SWING DOORS (R311.3.1)
16 WINDOW TO MEET EGRESS REQUIREMENTS - REF. DOOR AND WINDOW NOTES #6, SHT. A-7.0
17 ENCLOSED USEABLE SPACE UNDER STAIRWAY USE 5/8" TYPE 'X' GYP. BD. FINISH TYP. (1/2" MIN.) (CRC R302.7)
18 STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT
CANDLE (CBC 1205.4) REF. DTL. 3/AD-1
19 EXTERIOR WALL MOUNTED HANDRAIL - 34"-38" ABV. NOSING, REF. DTL. XX/AD-1
20 INTERIOR GUARDRAIL - MIN. 42" HIGH - MATERIAL AS SELECTED, <4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
21 RESIDENTIAL ELEVATOR - 'CALIFORNIA CUSTOM LIFT, INC.' OR EQUIV., SHAFT SIZE = 56" X 60" CLEAR - PROVIDE SHOP DWGS.
TO ARCH. PRIOR TO PURCHASE & INSTALLATION
NO. REVISION DATE
1/4" = 1'-0"1FIRST LEVEL FLOOR PLAN
PA2022-067
UP
DNDN
DN
DN
A-4.1
A-4.0
A-4.11
A-4.0
2
2
1
1
A-5.0
1
A-5.0
2
A-5.0
2
A-5.0
BONUS ROOM
ELEV.
PWDR.STAIRS
TV ABV.
POOL
WATER TROUGHINFINITY EDGEEXT. SHOWERREAR DECK
FIREPIT
BBQ
OUTDOOR DINING
MECH
LOUNGE DECKSPA
BAJA
6:12S.Y.S.B.3' - 0"S.Y.S.B.3' - 0"F.Y.S.B.
9' - 0"
R @ 0' - 7 1/2"16
R @0' - 7 3/4"6
R @0' - 7"8R @0' - 5 3/8"3
R @0' - 5 3/8"3
CLR.1' - 3"TYP.11"CLR.5' - 0 1/4"CLR.
4' - 6"
2% MIN.
2% MIN.2% MIN.
1
1
2
3
3
4
4
5
5
OPEN TO BELOW
6
TYP.
11"CLR.3' - 0 1/4"TYP.
11"
TYP.
11"CLR.3' - 0 3/4"7 8
9
10
10
7
7
8
8
11
11
12
13
14
14
34.60' T.O.W.
33.28' T.O.W.
31.10' T.O.W.
33.28' T.O.W.
31.94' T.O.R.
35.78' T.O.R.
35.78' T.O.R.
15
15
16
16
OPEN TO BLW.
19 21
20
22
23
24
21
68
31.10' F.F.CLR.3' - 0 1/4"CLR.
3' - 4 3/4"CLR.3' - 5"SECOND FLOOR
BALCONY
BELOW
ROOM TAGROOM NAME
1
A-5.0
1 1
?
1
1
A-4.0
1
1 1
1
ELEVATION / SECTION INDICATOR
AD-1.0
1 CALL-OUT TAG
10.00'SPOT ELEVATION
KEYNOTE TAG
REVISION TAG
DOOR / WINDOW / WINDOW WALL TAG
FIRE RATED CEILING ASS'Y - REF. DTLS. 7/AD-1.0
1-HR RATED INT CONDITION - REF. DTLS. 7/AD-1.0
1-HR RATED EXT CONDITION - REF. DTLS. 7/AD-1.0
STRUCTURAL STEEL COLUMN PER STRUCT., REF. STRUTC.
DWGS, - PAINT AND SEAL AS REQUIRED – ARCH. TO APPV.
COLOR FOR EXPOSED STEEL COLUMNS
STRUCTURAL WOOD POST/COLUMN COLUMN - PER STRUCT., REF. STRUTC. DWGS, -
PAINT, STAIN AND SEAL AS REQUIRED – ARCH. TO APPV. PAINT COLOR FOR EXPOSED
WOOD POST/COLUMN, IF TO BE STAINED PROVIDE STAINED SAMPLE FOR ARCH,
APPROVAL
DOORS - AS SPECIFIED, SEE WINDOW SCHEDULE AND GENERAL NOTES ON SHEET A-7.0 -
SHGC & U-FCTOR PER T-24 ENERGY REPORT – SEE SHEET AD-2.0 FOR JAMB, HEAD AND
THRESHOLD DETAILS, PROVIDE FLASHING AND WATERPROOFING AT DOOR OPENING PER
THE DOOR MFGR. INSTRUCTION AND/OR FLASHING MFGR. INSTRUCTION PER SECTIONS
R609.1 & R703.4 OF CRC
WINDOW - AS SPECIFIED, SEE WINDOW SCHEDULE AND GENERAL NOTES ON
SHEET A-7.0 - SHGC & U-FCTOR PER T-24 ENERGY REPORT – SEE SHEET
AD-2.0 FOR JAMB, HEAD AND SILL DETAILS, PROVIDE FLASHING AND
WATERPROOFING AT WINDOW OPENING PER THE WINDOW MFGR.
INSTRUCTION AND/OR FLASHING MFGR. INSTRUCTION PER SECTIONS R609.1
& R703.4 OF CRC
KITCHEN RANGE W/. EXHAUST HOOD - AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
PROVIDE POWER AND GAS AS REQUIRED - 30 ” MIN. VERTICAL CLEARANCE TO ANY
COMBUSTIBLE MATERIAL ABV. COOKING TOP (CMC 920.3.2) –EXHAUST HOOD TO HAVE
EXHAUST RATE OF MIN. 100 CFM AND VENT TO OUTDOOR , HOOD DUCTS TO BE OF
METAL WITH SMOOTH INTERIOR FINISH PER SECTION 504.3 OF CMC
KITCHEN/BAR SINK - AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER – SINK TO COMPLY
W/. REQUIREMENT OF SECTION 420.0 OF CPC AND HAVE A MAX FLOW RATE OF 1.8 GPM
@ 60 PSI PER SECTION 4.303.1 OF CALGREEN – TRAP AND VENT FOR ISLAND SINK AND
SIMILAR EQUIPMENT SHALL BE PER SECTION 909.0 OF CPC
VANITY SINK - AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
LAVATORY TO HAVE 24” MIN. CLEAR SPACE IN FRONT OF IT.(CPC 402.5)
W/. MAXIMUM FLOW RATE OF 1.2 GPM @ 60 PSI AND MIN. FLOW RATE OF
0.8 GPM @ 20 PSI PER SECTION 4.303.1 OF CALGREEN
WASHER (W) / DRYER (D) / STACKED (W/D) - AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER – PROVIDE POWER , GAS, WATER SUPPLY & DRAINAGE AS REQUIRED - THE
CLOTHES DRYERS VENT SHALL BE OF A RIGID METALLIC MATERIAL AND HAVE A BACKDRAFT DAMPER (CMC 504.4) AND SHALL NOT EXCEED 14-FEET IN OVERALL LENGTH
WITH MAX. OF TWO (2) 90-DEGREE ELBOW, SUBTRACT 2-FEET FOR EACH ADDITIONAL 90-
DEGREE ELBOW. SEE WASHER & DRYER NOTES, REF. T-1.1.
REFRIGERATOR (REF) / FREEZER (FRZ) - AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER – PROVIDE POWER AND WATER SUPPLY AS REQUIRED
BUILT-IN APPLIANCE / DISHWASHER (DW) / TRASH COMPACTOR (TR) - AS SELECTED PER
I.D., VERIFY W/. I.D. & OWNER – PROVIDE POWER , WATER SUPPLY & DRAINAGE PIPE AS
REQUIRED
TOILET - WATER CLOSET SHALL BE IN COMPLIANCE OF SECTION 411.0 OF CPC AND HAS
MAX EFFECTIVE FLUSH RATE OF 1.28 GAL. PER FLUSH (CPC 411.2). WATER CLOSETS
CLR. TO BE 24” IN FRONT AND 15” FROM ITS CENTER TO ANY SIDE WALL OR
OBSTRUCTION. (CPC 402.5 & CRC R307) – REF. CALGREEN NOTES ON T SHTS. FOR MAX
FLOW RATE
CASEWORK, TALL CABINET - AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER
CASEWORK, BASE CABINET W/. COUNTERTOP - AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER
CASEWORK, UPPER CABINET/SHELVES - AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER
BUILT-IN CLOSET - AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER
FIREPLACE - FACTORY-BUILT DIRECT VENT GAS FIREPLACE W/. SEALED COMBUSTION
(CALGREEN 4.503) - FACTORY-BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR
COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING
AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. (CRC R1004.1)
ELEVATOR - PRIVATE RESIDENCE ELEVATOR IN COMPLIANCE W/. ASME A17.1/CSA B44
AS SELECTED PER PLANS, VERIFY W/. OWNER – PROVIDE POWER AS REQ'D. (CRC 321.1)
A/C CONDENSER / HEAT PUMP - TO BE IN COMPLIANCE OF SECTION 307.3 OF CPC AS
SELECTED, VERIFY W/. OWNER - SIZE TBD, SEE T-24 ENERGY REPORT FOR MORE INFO –
PROVIDE POWER AND SOUND DAMPENING PAD AS REQ ’D. – INSTALL AND MAINTAIN
REQUIRED CLEARANCES PER MFGR. INSTRUCTION
FAU - PROVIDE GAS S.O., POWER, AND VENTING AS REQ'D. BY MFG'R. – INSTALL PER
MFGR. INSTRUCTION
ROOF/DECK DRAIN - PER CHAPTER 11 OF CPC - SIZE THE DRAIN AND PIPING PER TABLE
1103.1 AND 1103.2 OF CPC – ROOF DRAIN SHALL HAVE DOMED STRAINER (CPC 1102.2) –
REF. DETAIL 11/AD-1.0
OVERFLOW OR EMERGENCY DRAIN - PER CHAPTER 11 OF CPC - COPPER OR EQ., INSTALL
PER MFGR. INSTRUC., SLOPED TOWARD IN-WALL DRAIN INLETS – SLOPE AND SIZE PER
TABLE 1103.3 OF CPC – REF. DTL. 11/AD-1.0
UP
20R@7 1/2"
STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL OF NOT
LESS THAN 1 FOOT CANDLE AS MEASURED AT THE CENTER OF TREADS AND
LANDING WITH ARTIFICIAL LIGHTING (R303.7) - REF. DTL. 3/AD-1
ELEVATOR - PRIVATE RESIDENCE ELEVATOR IN COMPLIANCE W/. ASME A17.1/CSA B44
AS SELECTED PER PLANS, VERIFY W/. OWNER – PROVIDE POWER AS REQUIRED (CRC
R321.1)
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED, ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL THEN BE HELD HARMLESS AND ABSOLVED OF ANY LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
KEYNOTESB
ANNOTATION LEGENDA
BRANDON ARCHITECTS
03-22-2022
THIRD LEVEL FLOOR
PLANOCEAN FRONT POOL HOUSESMITH 507 LLC
1616 W. OCEAN FRONT,
NEWPORT BEACH , CA 92663
CDP SUBMITTAL
1616 W. OCEAN FRONT, NEWPORT
BEACH , CA 92663
A-2.1
**0000-2021**
ELIZABETH HANNA
1/4" = 1'-0"1THIRD LEVEL FLOOR PLAN
1 PROPERTY LINE
2 FRONT YARD SETBACK
3 SIDE YARD SETBACK
4 STRUCT. STEEL COLUMN - REF. STRUCT. DWGS. & PROVIDE SHOP DWGS. FOR ARCH. & ENGINEER APPV. PRIOR TO FAB.
5 DEPRESSED SLAB FOR SLIDING/POCKET DOORS - COORD. WITH DOOR MFG. & GENERAL CONTRACTOR.
6 A/C. CONDENSER UNIT - SIZE TBD - PROVIDE POWER AND SOUND DAMPENING PAD AS REQ'D. (SOUND ATTENUATION REQ'D.
PER SECTION 10.26.045 N.B.M.C. UNDER SEPARATE PERMIT & PLAN CHECK)
7 STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT
CANDLE (CBC 1205.4) REF. DTL. 3/AD-1
8 EXTERIOR WALL MOUNTED HANDRAIL - 34"-38" ABV. NOSING, REF. DTL. XX/AD-1
9 INTERIOR GUARDRAIL - MIN. 42" HIGH - MATERIAL AS SELECTED, <4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
10 PRECAST CONCRETE EXTERIOR STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL ON TREAD RUNS
OF NOT LESS THAN 1 FOOT CANDLE (CBC 1205.4) REF. DTL. X/AD-1
11 EXTERIOR GLASS GUARDRAIL - TEMPERED & LAMINATED - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
12 RESIDENTIAL ELEVATOR - 'CALIFORNIA CUSTOM LIFT, INC.' OR EQUIV., SHAFT SIZE = 56" X 60" CLEAR - PROVIDE SHOP DWGS.
TO ARCH. PRIOR TO PURCHASE & INSTALLATION
13 WOOD PANEL SIDING SCREEN - EXT. GRADE MDX, PAINT AS SEL., REF. MATERIAL SCHEDULE SHT. A-4.0
14 EXPOSED STRUCTURAL STEEL COLUMN TO SUPPORT STEEL WIRE TRELLIS, SIZE PER STRUCT.; PAINT & SEAL AS SEL. (ARCH.
TO APPV.)
15 DECK CHANNEL DRAIN - SLOPE 2% MIN. - REF. DTL. XX/AD-1
16 DECK DRAIN - SLOPE 2% MIN. - REF. DTL. 11/AD-1
NO. REVISION DATE
PA2022-067
UP
UP
UP
UP
UP
DNUP
UPUP
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE
NEAREST 1/8" AND INTERIOR PARTITIONS ARE DIMENSIONED FROM FACE OF STRUCTURE TO FACE OF STRUCTURE (F.O.S.) U.N.O. -
CONTACT ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
ROUGH FRAMING:
ALL EXTERIOR WALLS TO BE FRAMED W/. 2X6 STUD MIN. U.N.O.
USE 2X6 MINIMUM STUDS FOR PLUMBING WALLS
SECOND AND THIRD FLOOR PLYWOOD TO BE 1-1/8"
ENTIRE EXTERIOR TO BE SHEATHED WITH 1/2" PLYWOOD
DOORS AND WINDOWS WILL TYPICALLY BE RECESSED FROM EXTERIOR WALL PLANE. VERIFY ALL ROUGH OPENING DIMENSIONS
WITH DOOR AND WINDOW MFGR. ROUGH OPENING MAY NEED TO BE OVERSIZED TO ACCOUNT FOR ADDITIONAL FRAMING. SEE
SHT. AD-2.0 FOR TYP. RECESSED CONDITIONS.
GARAGE FLOOR:
GARAGE FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTIBLE MATERIAL.THE AREA OF FLOOR USED FOR PARKING OF
AUTOMOBILES OR OTHER VEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS TO A DRAIN OR TOWARD THE
MAIN VEHICLE ENTRY DOORWAY. (R309.1)
PLUMBING:
1. SUPPORT ALL WALL-HUNG FIXTURES WITH METAL SUPPORTING MEMBERS TO PREVENT ANY STRAIN TRANSMISSION TO THE
CONNECTIONS. FRAMING AFFIXED SUPPORTS FOR OFF-THE-FLOOR WATER CLOSETS WITH CONCEALED TANKS SHALL COMPLY
WITH ASME A112.6.2. SECURE FLUSH TANK AND SIMILAR APPURTENANCES WITH APPROVED NON-CORROSIVE SCREW OR BOLTS.
(CPC 402.5)
2. THE NET AREA OF THE SHOWER ENCLOSURE SHALL BE 1,024 SQ. INCHES (7.1 SQ. FT.) OR MORE IN THE CLEAR FLOOR AREA,
AND SHALL ALSO BE CAPABLE OF ENCOMPASSING A 30-INCH DIAMETER CIRCLE. (CPC 408.6)
3. THE WATER HEATER BURNER AND BURNER-IGNITION DEVICE TO BE AT LEAST 18-INCHES ABOVE THE FLOOR, IF LOCATED IN A
GARAGE AND IN ADJACENT SPACES THAT OPEN TO THE GARAGE. FOR WATER HEATER IN THE GARAGE OR OTHER AREAS SUBJECT
TO MECHANICAL DAMAGE PROVIDE A PROTECTIVE BARRIER OR ELEVATE THE APPLIANCE TO BE OUT OF THE NORMAL PATH OF THE VEHICLE. (CPC 507.13)
4. ANCHOR OR STRAP THE WATER HEATER(S) TO RESIST HORIZ. DISPLACEMENT DUE TO THE EARTHQUAKE. STRAPPING SHOULD
BE AT THE UPPER AND LOWER ONE THIRD (1/3) POINTS OF THE APPLIANCE HEIGHT. MAINTAIN A MIN. 4-INCHES ABOVE THE
CONTROLS WITH STRAPPING AT LOWER POINT.
WOOD OR WOODBASED PRODUCTS NOTE:
WOOD OR WOODBASE PRODUCT SHALL BE OF A NATURAL DURABLE OR PRESERVATIVE-TREADED WOOD IN ACCORDANCE WITH
AWPA U1 FOR THE SPECIES, PRODUCT, PRESERVATIVE AND END USE IN THE FOLLOWING LOCATIONS:
1. WOOD JOISTS OR THE BOTTOM OF A WOOD STRUCTURAL FLOOR WHEN CLOSER THAN 18 INCHES (457 MM) OR WOOD GIRDERS
WHEN CLOSER THAN 12 INCHES (305 MM) TO THE EXPOSED GROUND IN CRAWL SPACES OR UNEXCAVATED AREA LOCATED
WITHIN THE PERIPHERY OF THE BUILDING FOUNDATION.
2. WOOD FRAMING MEMBERS THAT REST ON CONCRETE OR MASONRY EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8
INCHES (203 MM) FROM THE EXPOSED GROUND.
3. SILLS AND SLEEPERS ON A CONCRETE OR MASONRY SLAB THAT IS IN DIRECT CONTACT WITH THE GROUND UNLESS
SEPARATED FROM SUCH SLAB BY AN IMPERVIOUS MOISTURE BARRIER.
4. THE ENDS OF WOOD GIRDERS ENTERING EXTERIOR MASONRY OR CONCRETE WALLS HAVING CLEARANCES OF LESS THAN 1/2
INCH (12.7 MM) ON TOPS, SIDES AND ENDS.
5. WOOD SIDING, SHEATHING AND WALL FRAMING ON THE EXTERIOR OF A BUILDING HAVING A CLEARANCE OF LESS THAN 6
INCHES (152 MM) FROM THE GROUND OR LESS THAN 2 INCHES (51 MM) MEASURED VERTICALLY FROM CONCRETE STEPS,
PORCH SLABS, PATIO SLABS AND SIMILAR HORIZONTAL SURFACES EXPOSED TO THE WEATHER.
6. WOOD STRUCTURAL MEMBERS SUPPORTING MOISTURE-PERMEABLE FLOORS OR ROOFS THAT ARE EXPOSED TO THE
WEATHER, SUCH AS CONCRETE OR MASONRY SLABS, UNLESS SEPARATED FROM SUCH FLOORS OR ROOFS BY AN IMPERVIOUS
MOISTURE BARRIER.
7. WOOD FURRING STRIPS OR OTHER WOOD FRAMING MEMBERS ATTACHED DIRECTLY TO THE INTERIOR OF EXTERIOR MASONRY
WALLS OR CONCRETE WALLS BELOW GRADE EXCEPT WHERE AN APPROVED VAPOR RETARDER IS APPLIED BETWEEN THE WALL
AND THE FURRING STRIPS OR FRAMING MEMBERS.
*HERS VERIFICATION REQUIRED- REFERENCE T-24.1
ROOM TAGROOM NAME
1
1
1
1
10.00'SPOT ELEVATION
REVISION TAG
DOOR TAG
WINDOW WALL TAG
WINDOW TAG
STRUCTURAL STEEL COLUMN PER STRUCT., REF. STRUTC.
DWGS, - PAINT AND SEAL AS REQUIRED – ARCH. TO APPV.
COLOR FOR EXPOSED STEEL COLUMNS
STRUCTURAL WOOD POST/COLUMN COLUMN - PER STRUCT., REF. STRUTC. DWGS, -
PAINT, STAIN AND SEAL AS REQUIRED – ARCH. TO APPV. PAINT COLOR FOR EXPOSED
WOOD POST/COLUMN, IF TO BE STAINED PROVIDE STAINED SAMPLE FOR ARCH,
APPROVAL
KITCHEN RANGE W/. EXHAUST HOOD - AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
PROVIDE POWER AND GAS AS REQUIRED - 30 ” MIN. VERTICAL CLEARANCE TO ANY
COMBUSTIBLE MATERIAL ABV. COOKING TOP (CMC 920.3.2) –EXHAUST HOOD TO HAVE
EXHAUST RATE OF MIN. 100 CFM AND VENT TO OUTDOOR , HOOD DUCTS TO BE OF
METAL WITH SMOOTH INTERIOR FINISH PER SECTION 504.3 OF CMC
KITCHEN/BAR SINK - AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER – SINK TO COMPLY
W/. REQUIREMENT OF SECTION 420.0 OF CPC AND HAVE A MAX FLOW RATE OF 1.8 GPM
@ 60 PSI PER SECTION 4.303.1 OF CALGREEN – TRAP AND VENT FOR ISLAND SINK AND
SIMILAR EQUIPMENT SHALL BE PER SECTION 909.0 OF CPC
VANITY SINK - AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
LAVATORY TO HAVE 24” MIN. CLEAR SPACE IN FRONT OF IT.(CPC 402.5)
W/. MAXIMUM FLOW RATE OF 1.2 GPM @ 60 PSI AND MIN. FLOW RATE OF
0.8 GPM @ 20 PSI PER SECTION 4.303.1 OF CALGREEN
WASHER (W) / DRYER (D) / STACKED (W/D) - AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER – PROVIDE POWER , GAS, WATER SUPPLY & DRAINAGE AS REQUIRED - THE
CLOTHES DRYERS VENT SHALL BE OF A RIGID METALLIC MATERIAL AND HAVE A
BACKDRAFT DAMPER (CMC 504.4) AND SHALL NOT EXCEED 14-FEET IN OVERALL LENGTH
WITH MAX. OF TWO (2) 90-DEGREE ELBOW, SUBTRACT 2-FEET FOR EACH ADDITIONAL 90-
DEGREE ELBOW. SEE WASHER & DRYER NOTES, REF. T-1.1.
TOILET - WATER CLOSET SHALL BE IN COMPLIANCE OF SECTION 411.0 OF CPC AND HAS
MAX EFFECTIVE FLUSH RATE OF 1.28 GAL. PER FLUSH (CPC 411.2). WATER CLOSETS
CLR. TO BE 24” IN FRONT AND 15” FROM ITS CENTER TO ANY SIDE WALL OR
OBSTRUCTION. (CPC 402.5 & CRC R307) – REF. CALGREEN NOTES ON T SHTS. FOR MAX
FLOW RATE
FIREPLACE - FACTORY-BUILT DIRECT VENT GAS FIREPLACE W/. SEALED COMBUSTION
(CALGREEN 4.503) - FACTORY-BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR
COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING
AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. (CRC R1004.1)
A/C CONDENSER / HEAT PUMP - TO BE IN COMPLIANCE OF SECTION 307.3 OF CPC AS
SELECTED, VERIFY W/. OWNER - SIZE TBD, SEE T-24 ENERGY REPORT FOR MORE INFO –
PROVIDE POWER AND SOUND DAMPENING PAD AS REQ ’D. – INSTALL AND MAINTAIN
REQUIRED CLEARANCES PER MFGR. INSTRUCTION
FAU - PROVIDE GAS S.O., POWER, AND VENTING AS REQ'D. BY MFG'R. – INSTALL PER
MFGR. INSTRUCTION
RECESSED MAIN SERVICE PANEL - 400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE
OF PANEL TO ANY OBSTRUCTION) – GC TO COORDINATE W/. UTILITY COMPANY
ROOF/DECK DRAIN - PER CHAPTER 11 OF CPC - SIZE THE DRAIN AND PIPING PER TABLE
1103.1 AND 1103.2 OF CPC – ROOF DRAIN SHALL HAVE DOMED STRAINER (CPC 1102.2) –
REF. DETAIL 11/AD-1.0
OVERFLOW OR EMERGENCY DRAIN - PER CHAPTER 11 OF CPC - COPPER OR EQ., INSTALL
PER MFGR. INSTRUC., SLOPED TOWARD IN-WALL DRAIN INLETS – SLOPE AND SIZE PER
TABLE 1103.3 OF CPC – REF. DTL. 11/AD-1.0
2X4 STUD WALL
2X6 STUD WALL
2X8 STUD WALL
2X10 STUD WALL
EXT. POCKET DOOR WALL - TYP. 2X6 EXT. FRMG. AND 2X4 INTERIOR FRAMING W/.
DOUBLE TOP PLATE AND SINGLE SILL PLATE U.N.O., MIN. AIR SPACE/DOOR POCKET
TO BE VERIFIED W/. DOOR MFGR. - STUDS MIN. SPACING PER STRUCT. AND EXT.
FINISH MFGR. INSTRUCTION AND/OR LISTING – SEE EXT. WALL DETAILS AND STRUCT.
DWGS
CONCRETE WALL - 12” REINFORCED CAST IN PLACE CONCRETE WALL TYP. U.N.O. PER
STRUCT., REF. STRCUTC. DWGS. – FOR BASEMENT/RETAINING CONCRETE WALL
PROVIDE WATERPROOFING OR DAMPPROOFING AND DRAINAGE AS REQUIRED PER SECTION R406.1 & R406.2, REF. SOILS REPORT,WATERPROOFING & DAMPROOFING
NOTES ON SHEET T-1.1 – EXPOSED SURFACES TO HAVE TROWELED SMOOTH FINISH
WITH A LIGHT GRAY COLOR, PROVIDE SAMPLE FOR ARCH. APPROVAL
SLAB/FRAMING DEPRESSION - SEE STRUCT. DWGS. FOR THE RECESSION DETAILS -
FOR RECESSION SPECIFIC TO EQUIPMENT OR ASSEMBLY VERIFY THE REQUIRED
RECESSION W/. MFGR. OR FABRICATOR – SHOWER RECESSION TO BE VERIFIED W/.
I.D.
SEE SHEET AD-2.0 FOR THE TYPICAL DEPRESSION OF DOORS AND WINDOWS, VERIFY
ALL DEPRESSIONS W/. MFGR.
STUDS MIN. SPACING PER STRUCT. AND EXT. FINISH MFGR.
INSTRUCTION AND/OR LISTING – SEE EXT. WALL DETAILS AND
STRUCT. DWGS
VERTICAL STORM DRAIN PIPE IN-WALL / OVERFLOW - MTL. PIPE PER
CHAPTER 11 OF CPC, SIZE PER TABLE 1103.1 (MIN. 2 ” DIA. PIPE & TYP. 3” DIA. PIPE) –
SEE CIVIL DWGS. FOR TERMINATION DTLS. ABV. OR BLW. GROUND. VERIFY ALL
TERMINATION POINTS, TYPE AND DETAILS W/. CIVIL PRIOR TO POURING THE CONCRETE
SLAB
OVERFLOW
DRAINLINE
A-4.1
A-4.0
A-4.11
A-4.0
2
2
1
1
A-5.0
1
A-5.0
2
A-5.0
2
A-5.0
LOUNGEKITCHEN
DINING
GREAT ROOMFOYER
GIRL'S POOL BATH
2-CAR GARAGE
SAND ROOM BOY'S POOL BATH
ELEV.
STAIRS
ENTRY
R @ 0' - 7 1/2"2
R @0' - 7 1/2"20
R @0' - 7"2
R @ 0' - 7 3/8"16
S.Y.S.B.3' - 0"S.Y.S.B.3' - 0"F.Y.S.B.
9' - 0"CLR.4' - 6"CLR.
4' - 6"
SHOWER
STORAGE
SHOWER
GATELINE OF FLOOR ABV.GOLF CART PARKING
DOUBLE SHOWER CLR.20' - 6 1/4"CLR.
19' - 1 1/4"TYP.11"CLR.
3' - 6"
LINE OF FLOOR ABV.
LINE OF FLOOR ABV.
SLAB DEPRESSION FOR
FIREPLACE VERIFY W/.
G.C.& MFGR.
GATE
14' - 10"86' - 5 1/4"1' - 2"3' - 9"23' - 0 3/4"3' - 2"3' - 2"23' - 7 3/4"3' - 2"1' - 0 7/8"21' - 6"1' - 0 7/8"5 1/8"5 1/8"SLAB DEPRESSION
FOR FIREPLACE VERIFY
W/. G.C.& MFGR.
SLAB DEPRESSION FOR
SHOWER VERIFY W/. G.C.
SLAB DEPRESSION FOR
SHOWER VERIFY W/. G.C.
SLAB DEPRESSION
FOR SLIDER DOOR
VERIFY W/. G.C.
14' - 10"86' - 5 1/4"1' - 2"
5' - 1 1/2"35' - 11"17' - 6 1/2"7' - 0 3/4"6' - 2 1/2"19' - 8 1/2"
9' - 6 7/8"10' - 7 1/4"8' - 6"7' - 2 7/8"9' - 3 3/8"8' - 3 1/8"3' - 9 5/8"3' - 3 1/8"1' - 10 1/8"8' - 0"4' - 7 1/4"5' - 3 1/4"1' - 6 1/2"1' - 6 5/8"18' - 6"1' - 5 5/8"5' - 1 1/2"35' - 11"13' - 0 3/4"37' - 5 1/2"
6' - 3 3/8"6' - 7 1/8"23' - 0 1/2"13' - 0 3/4"5' - 6 3/4"12' - 1 3/4"19' - 9"
1' - 9 5/8"13' - 6 5/8"11' - 3 3/8"5' - 3 1/4"3' - 5 7/8"2' - 9 1/2"6' - 7 1/8"2' - 9 1/2"8' - 11 3/8"11' - 3 5/8"2' - 3 3/8"8' - 6"2' - 3 3/8"
8 3/4"
1' - 6 5/8" 2' - 0"4' - 6"2' - 0" 1' - 6 5/8"
8 3/4"1' - 6 1/2"7' - 4"2' - 6"4' - 4 3/4"7' - 3 5/8"5' - 8"1' - 6"4' - 7 1/4"8' - 2 7/8"3' - 7 5/8"1' - 0"
1' - 0"20' - 5 1/8"3' - 2 5/8"6
5
4
10
11
121
111012
5
3
2
3
89
978
4
6
7
9.1
8.1
BALCONY OVERHANG
3' - 0"
A-4.1
A-4.0
A-4.11
A-4.0
2
2
1
1
A-5.0
1
A-5.0
2
A-5.0
2
A-5.0
S.Y.S.B.3' - 0"S.Y.S.B.3' - 0"F.Y.S.B.
9' - 0"
MASTER SUITE
BATH #2
MASTER BATH
ELEV.
STAIRS
BEDROOM #2
W/C.
BALCONY
6' - 1"95' - 4 1/4"1' - 0"3' - 7"23' - 2 3/4"3' - 2"6' - 1"95' - 4 1/4"1' - 0"3' - 2"23' - 8 1/4"3' - 1 1/2"POOL STRUCTURE 2% MIN.
SLAB DEPRESSION FOR
SHOWER VERIFY W/. G.C.
SLAB DEPRESSION FOR
SHOWER VERIFY W/.
G.C.
SLAB DEPRESSION FOR
SLIDER DOOR VERIFY W/. G.C.
3' - 0 1/2"52' - 0"34' - 11 3/4"1' - 3" 4' - 1"
5' - 7 3/8"11' - 11 1/8"6' - 4 3/4"8' - 4 1/4"
1' - 9"8' - 1"2' - 1 1/8" 4' - 6 1/8" 1' - 10 5/8"3"13' - 5 1/4"12' - 10 1/4"14' - 10 1/4"13' - 3 3/8"2 3/8"
3' - 0 1/2"54' - 4 1/4"33' - 10 1/2"4' - 1"
5 1/4"
5 1/4"52' - 0"2' - 4 1/4"11' - 6 3/4"5' - 6 3/4"16' - 9"
2' - 0 5/8"7' - 6"2' - 0 1/8" 3' - 3" 2' - 3 3/4" 3' - 9 5/8"9' - 9 1/2"3' - 1 7/8"3"13' - 5 1/4"13' - 10 1/4"13' - 10 1/4"10' - 7 1/8"1' - 4 1/2"16' - 0 1/2"5' - 7 3/4" 2"1' - 4"12' - 0"1' - 4 1/2"5' - 7 3/4"1' - 4"14' - 8 1/2"2' - 10 7/8"2' - 8 7/8"4 7/8"4 1/4"16
3
18
13
13
15
18
16
17
15
12
14
19
20
17
14
17.1
14.1
BALCONY OVERHANG
3' - 0"
EXT.
MECH.
EXTERIOR HALLWAY
BALCONY
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED, ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL THEN BE HELD HARMLESS AND ABSOLVED OF ANY LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
ANNOTATION LEGEND
GENERAL NOTESA
B
03-22-2022
FIRST AND SECOND
LEVEL DIMENSION
PLANOCEAN FRONT POOL HOUSESMITH 507 LLC
1616 W. OCEAN FRONT,
NEWPORT BEACH , CA 92663
CDP SUBMITTAL
1616 W. OCEAN FRONT, NEWPORT
BEACH , CA 92663
A-2.2
**0000-2021**
ELIZABETH HANNA
NO. REVISION DATE
1/4" = 1'-0"1FIRST LEVEL DIMENSION PLAN
1/4" = 1'-0"2SECOND LEVEL DIMENSION PLAN
PA2022-067
UP
UP
DN
UP
UP
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE
NEAREST 1/8" AND INTERIOR PARTITIONS ARE DIMENSIONED FROM FACE OF STRUCTURE TO FACE OF STRUCTURE (F.O.S.) U.N.O. -
CONTACT ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
ROUGH FRAMING:
ALL EXTERIOR WALLS TO BE FRAMED W/. 2X6 STUD MIN. U.N.O.
USE 2X6 MINIMUM STUDS FOR PLUMBING WALLS
SECOND AND THIRD FLOOR PLYWOOD TO BE 1-1/8"
ENTIRE EXTERIOR TO BE SHEATHED WITH 1/2" PLYWOOD
DOORS AND WINDOWS WILL TYPICALLY BE RECESSED FROM EXTERIOR WALL PLANE. VERIFY ALL ROUGH OPENING DIMENSIONS
WITH DOOR AND WINDOW MFGR. ROUGH OPENING MAY NEED TO BE OVERSIZED TO ACCOUNT FOR ADDITIONAL FRAMING. SEE
SHT. AD-2.0 FOR TYP. RECESSED CONDITIONS.
GARAGE FLOOR:
GARAGE FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTIBLE MATERIAL.THE AREA OF FLOOR USED FOR PARKING OF
AUTOMOBILES OR OTHER VEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS TO A DRAIN OR TOWARD THE
MAIN VEHICLE ENTRY DOORWAY. (R309.1)
PLUMBING:
1. SUPPORT ALL WALL-HUNG FIXTURES WITH METAL SUPPORTING MEMBERS TO PREVENT ANY STRAIN TRANSMISSION TO THE
CONNECTIONS. FRAMING AFFIXED SUPPORTS FOR OFF-THE-FLOOR WATER CLOSETS WITH CONCEALED TANKS SHALL COMPLY
WITH ASME A112.6.2. SECURE FLUSH TANK AND SIMILAR APPURTENANCES WITH APPROVED NON-CORROSIVE SCREW OR BOLTS.
(CPC 402.5)
2. THE NET AREA OF THE SHOWER ENCLOSURE SHALL BE 1,024 SQ. INCHES (7.1 SQ. FT.) OR MORE IN THE CLEAR FLOOR AREA,
AND SHALL ALSO BE CAPABLE OF ENCOMPASSING A 30-INCH DIAMETER CIRCLE. (CPC 408.6)
3. THE WATER HEATER BURNER AND BURNER-IGNITION DEVICE TO BE AT LEAST 18-INCHES ABOVE THE FLOOR, IF LOCATED IN A
GARAGE AND IN ADJACENT SPACES THAT OPEN TO THE GARAGE. FOR WATER HEATER IN THE GARAGE OR OTHER AREAS SUBJECT
TO MECHANICAL DAMAGE PROVIDE A PROTECTIVE BARRIER OR ELEVATE THE APPLIANCE TO BE OUT OF THE NORMAL PATH OF THE VEHICLE. (CPC 507.13)
4. ANCHOR OR STRAP THE WATER HEATER(S) TO RESIST HORIZ. DISPLACEMENT DUE TO THE EARTHQUAKE. STRAPPING SHOULD
BE AT THE UPPER AND LOWER ONE THIRD (1/3) POINTS OF THE APPLIANCE HEIGHT. MAINTAIN A MIN. 4-INCHES ABOVE THE CONTROLS WITH STRAPPING AT LOWER POINT.
WOOD OR WOODBASED PRODUCTS NOTE:
WOOD OR WOODBASE PRODUCT SHALL BE OF A NATURAL DURABLE OR PRESERVATIVE-TREADED WOOD IN ACCORDANCE WITH
AWPA U1 FOR THE SPECIES, PRODUCT, PRESERVATIVE AND END USE IN THE FOLLOWING LOCATIONS:
1. WOOD JOISTS OR THE BOTTOM OF A WOOD STRUCTURAL FLOOR WHEN CLOSER THAN 18 INCHES (457 MM) OR WOOD GIRDERS
WHEN CLOSER THAN 12 INCHES (305 MM) TO THE EXPOSED GROUND IN CRAWL SPACES OR UNEXCAVATED AREA LOCATED
WITHIN THE PERIPHERY OF THE BUILDING FOUNDATION.
2. WOOD FRAMING MEMBERS THAT REST ON CONCRETE OR MASONRY EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8
INCHES (203 MM) FROM THE EXPOSED GROUND.
3. SILLS AND SLEEPERS ON A CONCRETE OR MASONRY SLAB THAT IS IN DIRECT CONTACT WITH THE GROUND UNLESS
SEPARATED FROM SUCH SLAB BY AN IMPERVIOUS MOISTURE BARRIER.
4. THE ENDS OF WOOD GIRDERS ENTERING EXTERIOR MASONRY OR CONCRETE WALLS HAVING CLEARANCES OF LESS THAN 1/2
INCH (12.7 MM) ON TOPS, SIDES AND ENDS.
5. WOOD SIDING, SHEATHING AND WALL FRAMING ON THE EXTERIOR OF A BUILDING HAVING A CLEARANCE OF LESS THAN 6
INCHES (152 MM) FROM THE GROUND OR LESS THAN 2 INCHES (51 MM) MEASURED VERTICALLY FROM CONCRETE STEPS,
PORCH SLABS, PATIO SLABS AND SIMILAR HORIZONTAL SURFACES EXPOSED TO THE WEATHER.
6. WOOD STRUCTURAL MEMBERS SUPPORTING MOISTURE-PERMEABLE FLOORS OR ROOFS THAT ARE EXPOSED TO THE
WEATHER, SUCH AS CONCRETE OR MASONRY SLABS, UNLESS SEPARATED FROM SUCH FLOORS OR ROOFS BY AN IMPERVIOUS
MOISTURE BARRIER.
7. WOOD FURRING STRIPS OR OTHER WOOD FRAMING MEMBERS ATTACHED DIRECTLY TO THE INTERIOR OF EXTERIOR MASONRY
WALLS OR CONCRETE WALLS BELOW GRADE EXCEPT WHERE AN APPROVED VAPOR RETARDER IS APPLIED BETWEEN THE WALL
AND THE FURRING STRIPS OR FRAMING MEMBERS.
*HERS VERIFICATION REQUIRED- REFERENCE T-24.1
ROOM TAGROOM NAME
1
1
1
1
10.00'SPOT ELEVATION
REVISION TAG
DOOR TAG
WINDOW WALL TAG
WINDOW TAG
STRUCTURAL STEEL COLUMN PER STRUCT., REF. STRUTC.
DWGS, - PAINT AND SEAL AS REQUIRED – ARCH. TO APPV.
COLOR FOR EXPOSED STEEL COLUMNS
STRUCTURAL WOOD POST/COLUMN COLUMN - PER STRUCT., REF. STRUTC. DWGS, -
PAINT, STAIN AND SEAL AS REQUIRED – ARCH. TO APPV. PAINT COLOR FOR EXPOSED
WOOD POST/COLUMN, IF TO BE STAINED PROVIDE STAINED SAMPLE FOR ARCH,
APPROVAL
KITCHEN RANGE W/. EXHAUST HOOD - AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
PROVIDE POWER AND GAS AS REQUIRED - 30 ” MIN. VERTICAL CLEARANCE TO ANY
COMBUSTIBLE MATERIAL ABV. COOKING TOP (CMC 920.3.2) –EXHAUST HOOD TO HAVE
EXHAUST RATE OF MIN. 100 CFM AND VENT TO OUTDOOR , HOOD DUCTS TO BE OF
METAL WITH SMOOTH INTERIOR FINISH PER SECTION 504.3 OF CMC
KITCHEN/BAR SINK - AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER – SINK TO COMPLY
W/. REQUIREMENT OF SECTION 420.0 OF CPC AND HAVE A MAX FLOW RATE OF 1.8 GPM
@ 60 PSI PER SECTION 4.303.1 OF CALGREEN – TRAP AND VENT FOR ISLAND SINK AND
SIMILAR EQUIPMENT SHALL BE PER SECTION 909.0 OF CPC
VANITY SINK - AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
LAVATORY TO HAVE 24” MIN. CLEAR SPACE IN FRONT OF IT.(CPC 402.5)
W/. MAXIMUM FLOW RATE OF 1.2 GPM @ 60 PSI AND MIN. FLOW RATE OF
0.8 GPM @ 20 PSI PER SECTION 4.303.1 OF CALGREEN
WASHER (W) / DRYER (D) / STACKED (W/D) - AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER – PROVIDE POWER , GAS, WATER SUPPLY & DRAINAGE AS REQUIRED - THE
CLOTHES DRYERS VENT SHALL BE OF A RIGID METALLIC MATERIAL AND HAVE A
BACKDRAFT DAMPER (CMC 504.4) AND SHALL NOT EXCEED 14-FEET IN OVERALL LENGTH
WITH MAX. OF TWO (2) 90-DEGREE ELBOW, SUBTRACT 2-FEET FOR EACH ADDITIONAL 90-
DEGREE ELBOW. SEE WASHER & DRYER NOTES, REF. T-1.1.
TOILET - WATER CLOSET SHALL BE IN COMPLIANCE OF SECTION 411.0 OF CPC AND HAS
MAX EFFECTIVE FLUSH RATE OF 1.28 GAL. PER FLUSH (CPC 411.2). WATER CLOSETS
CLR. TO BE 24” IN FRONT AND 15” FROM ITS CENTER TO ANY SIDE WALL OR
OBSTRUCTION. (CPC 402.5 & CRC R307) – REF. CALGREEN NOTES ON T SHTS. FOR MAX
FLOW RATE
FIREPLACE - FACTORY-BUILT DIRECT VENT GAS FIREPLACE W/. SEALED COMBUSTION
(CALGREEN 4.503) - FACTORY-BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR
COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING
AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. (CRC R1004.1)
A/C CONDENSER / HEAT PUMP - TO BE IN COMPLIANCE OF SECTION 307.3 OF CPC AS
SELECTED, VERIFY W/. OWNER - SIZE TBD, SEE T-24 ENERGY REPORT FOR MORE INFO –
PROVIDE POWER AND SOUND DAMPENING PAD AS REQ ’D. – INSTALL AND MAINTAIN
REQUIRED CLEARANCES PER MFGR. INSTRUCTION
FAU - PROVIDE GAS S.O., POWER, AND VENTING AS REQ'D. BY MFG'R. – INSTALL PER
MFGR. INSTRUCTION
RECESSED MAIN SERVICE PANEL - 400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE
OF PANEL TO ANY OBSTRUCTION) – GC TO COORDINATE W/. UTILITY COMPANY
ROOF/DECK DRAIN - PER CHAPTER 11 OF CPC - SIZE THE DRAIN AND PIPING PER TABLE
1103.1 AND 1103.2 OF CPC – ROOF DRAIN SHALL HAVE DOMED STRAINER (CPC 1102.2) –
REF. DETAIL 11/AD-1.0
OVERFLOW OR EMERGENCY DRAIN - PER CHAPTER 11 OF CPC - COPPER OR EQ., INSTALL
PER MFGR. INSTRUC., SLOPED TOWARD IN-WALL DRAIN INLETS – SLOPE AND SIZE PER
TABLE 1103.3 OF CPC – REF. DTL. 11/AD-1.0
2X4 STUD WALL
2X6 STUD WALL
2X8 STUD WALL
2X10 STUD WALL
EXT. POCKET DOOR WALL - TYP. 2X6 EXT. FRMG. AND 2X4 INTERIOR FRAMING W/.
DOUBLE TOP PLATE AND SINGLE SILL PLATE U.N.O., MIN. AIR SPACE/DOOR POCKET
TO BE VERIFIED W/. DOOR MFGR. - STUDS MIN. SPACING PER STRUCT. AND EXT.
FINISH MFGR. INSTRUCTION AND/OR LISTING – SEE EXT. WALL DETAILS AND STRUCT.
DWGS
CONCRETE WALL - 12” REINFORCED CAST IN PLACE CONCRETE WALL TYP. U.N.O. PER
STRUCT., REF. STRCUTC. DWGS. – FOR BASEMENT/RETAINING CONCRETE WALL
PROVIDE WATERPROOFING OR DAMPPROOFING AND DRAINAGE AS REQUIRED PER SECTION R406.1 & R406.2, REF. SOILS REPORT,WATERPROOFING & DAMPROOFING
NOTES ON SHEET T-1.1 – EXPOSED SURFACES TO HAVE TROWELED SMOOTH FINISH
WITH A LIGHT GRAY COLOR, PROVIDE SAMPLE FOR ARCH. APPROVAL
SLAB/FRAMING DEPRESSION - SEE STRUCT. DWGS. FOR THE RECESSION DETAILS -
FOR RECESSION SPECIFIC TO EQUIPMENT OR ASSEMBLY VERIFY THE REQUIRED
RECESSION W/. MFGR. OR FABRICATOR – SHOWER RECESSION TO BE VERIFIED W/.
I.D.
SEE SHEET AD-2.0 FOR THE TYPICAL DEPRESSION OF DOORS AND WINDOWS, VERIFY
ALL DEPRESSIONS W/. MFGR.
STUDS MIN. SPACING PER STRUCT. AND EXT. FINISH MFGR.
INSTRUCTION AND/OR LISTING – SEE EXT. WALL DETAILS AND
STRUCT. DWGS
VERTICAL STORM DRAIN PIPE IN-WALL / OVERFLOW - MTL. PIPE PER
CHAPTER 11 OF CPC, SIZE PER TABLE 1103.1 (MIN. 2 ” DIA. PIPE & TYP. 3” DIA. PIPE) –
SEE CIVIL DWGS. FOR TERMINATION DTLS. ABV. OR BLW. GROUND. VERIFY ALL
TERMINATION POINTS, TYPE AND DETAILS W/. CIVIL PRIOR TO POURING THE CONCRETE
SLAB
OVERFLOW
DRAINLINE
A-4.1
A-4.0
A-4.11
A-4.0
2
2
1
1
A-5.0
1
A-5.0
2
A-5.0
2
A-5.0
S.Y.S.B.3' - 0"S.Y.S.B.3' - 0"F.Y.S.B.
9' - 0"
BONUS ROOM
ELEV.
PWDR.STAIRS
R @ 0' - 7 1/2"16
R @0' - 7 3/4"6
R @0' - 7"8
R @0' - 5 3/8"3
R @0' - 5 3/8"3
SLAB DEPRESSION FOR
SLIDER DOOR VERIFY W/. G.C.
POOL
LOUNGE DECKSPA
BAJA
6' - 1"95' - 3"1' - 1 1/4"3' - 8"23' - 2 3/4"3' - 1"6' - 1"95' - 3"1' - 1 1/4"3' - 0 3/4"23' - 10 1/4"3' - 0 3/4"3' - 0 1/2"54' - 8 1/4"17' - 7 3/4"5' - 10 3/4"8' - 10"5' - 1 3/4"
5' - 7 3/8"5' - 9 1/2"6' - 2 7/8"
11"
36" MIN.CLR.3' - 0 3/4"OPEN TO BLW.1' - 6 1/2"4 1/2"15' - 7 1/2"4' - 3 1/4" 1' - 5"1' - 5"1' - 9 5/8"2' - 5 5/8"2' - 0 3/8"2 7/8"12' - 1 1/4"1' - 3"6:12CLR.3' - 5 5/8"CLR.
3' - 5 3/8"TYP.11"3' - 0 1/2"62' - 11 7/8"15' - 2 7/8"10' - 1"3' - 10 3/4"
2' - 10 3/8"9' - 6 1/8"2' - 10 3/8"
2' - 9 5/8"2' - 9 1/8" 2' - 8 7/8"
3' -
0
3
/
4
"3' - 0 3/4"3' - 8 1/8"16' - 6"3' - 8 1/8"3/4"3/4"3 3/4"3 3/4"3"
3"
CLR.
3' - 10 7/8"
19 21
20
22
23
24
21
68
REAR DECK
SECOND FLOOR
BALCONY
BELOW
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED, ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL THEN BE HELD HARMLESS AND ABSOLVED OF ANY LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
ANNOTATION LEGEND
GENERAL NOTESA
B
03-22-2022
THIRD LEVEL
DIMENSION PLANOCEAN FRONT POOL HOUSESMITH 507 LLC
1616 W. OCEAN FRONT,
NEWPORT BEACH , CA 92663
CDP SUBMITTAL
1616 W. OCEAN FRONT, NEWPORT
BEACH , CA 92663
A-2.3
**0000-2021**
ELIZABETH HANNA
NO. REVISION DATE
1/4" = 1'-0"1THIRD LEVEL DIMENSION PLAN
PA2022-067
DIMENSION NOTE:
ALL DIMS. ARE TO FACE OF STUD (F.O.S.) OR FACE OF SHT'G. (F.O.S.) TYP. U.N.O. EAVE DIMS. ARE FROM FACE OF SHT'G. TO FACE
OF FINISH FASCIA
ENLOSED ATTIC AND ENCLOSED RAFTER SPACES VENTING NOTES:
1. ENCLOSED ATTIC AND ENCLOSED RAFTER SPACES SHALL HAVE CROSS VENTILATION BY VENTILATION OPENING PROTECTED
AGAINST THE ENTRANCE OF RAIN OR SNOW UNLESS THEY MEET THE REQUIREMENT OF SECTION R806.5 FOR UNVENTED ATTIC
AND UNVENTED ENCLOSED RAFTER ASSEMBLIES. VENTILATION OPENING SHALL HAVE THE LEAST DIMENSION OF 1/16 ” MIN. AND
1/4” MAX OTHERWISE THE OPENING SHALL HAVE THE CORROSION-RESISTANT WIRE CLOTH SCREENING, HARDWARE CLOTH,
PERFORATED VINYL OR SIMILAR MATERIAL WITH OPENINGS HAVE A LEAST DIMENSION OF 1/16 ” MIN. AND 1/4” MAX. OPENING IN
ROOF FRAMING MEMBERS SHALL BE PER THE REQUIREMENT OF SECTION R802.7. REQUIRED VENTILATION OPENINGS SHALL
OPEN DIRECTLY TO THE OUTSIDE AIR AND SHALL BE PROTECTED TO PREVENT THE ENTRY OF BIRDS, RODENTS, SNAKES AND
OTHER SIMILAR CREATURES. (R806.1)
2. THE MINIMUM NET FREE VENTILATING AREA SHOULD BE 1/150 OF THE AREA OF THE VENTED SPACE, EXCEPT FOR THE PROJECT
LOCATED IN CLIMATE ZONE 14 OR 16 WITH A CLASS I OR II VAPOR RETARDER AT THE WARM-IN-WINTER SIDE OF THE CEILING
AND WHERE MIN. 40% AND MAX 50% OF THE REQUIRED VENTILATION PROVIDED IN THE UPPER PORTION OF THE ATTIC OR
RAFTER SPACE PER SECTION R806.2 THEN THE MINIMUM NET FREE VENTILATING AREA CAN BE 1/300 OF THE VENTED SPACE.
(R802.2)
3. PROVIDE 1” SPACE BETWEEN THE INSULATION AND THE ROOF SHEATHING WHERE EAVE OR CORNICE VENTS PROVIDE
BLOCKING, BRIDGING AND INSULATION SHALL NOT BLOCK THE FREE FLOW OF AIR. (R806.3)
4. INSTALL VENTILATOR PER MANUFACTURER INSTRUCTION. INSTALL VENTILATOR IN ROOF PER SECTION R903 AND VENTILATOR
IN WALL ASSEMBLIES PER SECTION R703.1.
5. FOR THE ATTIC WITH VERTICAL HEIGHT GREATER THAN OR EQUAL TO 30 ” (VERTICAL HEIGHT MEASURED FROM THE TOP OF
CEILING JOIST TO THE BOTTOM OF THE ROOF RAFTERS) WITHIN 30S.F. MIN. PROVIDE THE OPENING WITH ROUGH-FRAMED
OPENING OF NOT LESS THAN 22”X30” WHICH SHOULD BE LOCATED IN HALLWAY OR OTHER LOCATION WITH READY ACCESS. IF
THE ACCESS LOCATED IN THE WALL THEN THE WIDTH SHOULD BE 22 ” AND HEIGHT SHOULD BE 30” MIN. IF LOCATED IN CEILING
THEN THE MIN. UNOBSTRUCTED HEADROOM IN THE ATTIC SHOULD BE 30 ” FROM THE BOTTOM OF CEILING JOIST AT SOME POINT.
ROOF DRAINAGE:
IF THE PROJECT LOCATED IN THE AREA WITH EXPANSIVE OR COLLAPSIBLE SOILS, WATER RUNOFF FROM ROOFS OF ALL
DWELLINGS SHALL BE DISCHARGED TO THE GROUND SURFACE NOT LESS THAN 5 FEET FROM FOUNDATION WALLS OR TO AN
APPROVED DRAINAGE SYSTEM. (R801.3) - REF.CIVIL DWGS FOR STORM WATER MANAGMENT AND SYSTEM.
WEATHER PROTECTION:
1. ROOF DECKS SHALL BE COVERED WITH APPROVED ROOF COVERINGS SECURED TO THE BUILDING OR STRUCTURE IN
ACCORDANCE WITH THE CHAPTER 9 OF THE CURRENT CRC. ROOF ASSEMBLIES SHALL BE DESIGNED AND INSTALLED IN
ACCORDANCE WITH THE CHAPTER 9 OF CRC AND THE APPROVED MANUFACTURER ’S INSTRUCTIONS SUCH THAT THE ROOF
ASSEMBLY SHALL SERVE TO PROTECT THE BUILDING OR STRUCTURE. (R903.1)
2. PROVIDE AND INSTALL FLASHING TO PREVENT ENTRY OF MOISTURE TO WALL AND ROOF ASSEMBLIES THRU THE JOINTS IN
COPINGS, PERMEABLE MATERIAL, AND AT INTERSECTION WITH PARAPET WALLS AND OTHER PENETRATION THRU ROOF. (R903.2)
3. FLASHINGS SHALL BE INSTALLED AT WALL AND ROOF INTERSECTIONS, WHEREVER THERE IS A CHANGE IN ROOF SLOPE OR
DIRECTION AND AROUND ROOF OPENINGS. A FLASHING SHALL BE INSTALLED TO DIVERT THE WATER AWAY FROM WHERE THE
EAVE OF A SLOPED ROOF INTERSECTS A VERTICAL SIDEWALL. WHERE FLASHING IS OF METAL, THE METAL SHALL BE CORROSION
RESISTANT WITH A THICKNESS OF NOT LESS THAN 0.019 INCH (0.5 MM) (NO. 26 GALVANIZED SHEET). (R903.2.1)
4. A CRICKET OR SADDLE SHALL BE INSTALLED ON THE RIDGE SIDE OF ANY CHIMNEY OR PENETRATION MORE THAN 30 INCHES
(762 MM) WIDE AS MEASURED PERPENDICULAR TO THE SLOPE. CRICKET OR SADDLE COVERINGS SHALL BE SHEET METAL OR OF
THE SAME MATERIAL AS THE ROOF COVERING. EXCEPT FOR UNIT SKYLIGHTS INSTALLED IN ACCORDANCE WITH HYPERLINK
"HTTPS://CODES.ICCSAFE.ORG/LOOKUP/CRC2019P1_PT03_CH03_SECR308.6" SECTION R308.6 AND FLASHED IN ACCORDANCE
WITH THE MANUFACTURER’S INSTRUCTIONS SHALL BE PERMITTED TO BE INSTALLED WITHOUT A CRICKET OR SADDLE. (R903.2)
5. PARAPET WALLS SHALL BE PROPERLY COPED WITH NONCOMBUSTIBLE, WEATHERPROOF MATERIALS OF A WIDTH NOT LESS
THAN THE THICKNESS OF THE PARAPET WALL. (R903.3)
6. UNLESS ROOFS ARE SLOPED TO DRAIN OVER ROOF EDGES, ROOF DRAINS SHALL BE INSTALLED AT EACH LOW POINT OF THE
ROOF. IF WATER CAN BE ENTRAPPED WITHIN THE ROOF AREA THEN SECONDARY EMERGENCY OVERFLOW ROOF DRAINS OR
SCUPPERS SHALL BE PROVIDED PER SECTION R903.4.1. (R903.4)
MISC. NOTES:
1. INSTALL ROOF PER ROOFING MFG'R. SPECS & INSTALLATION GUIDELINE
2. ARCH. TO APPV. SIZE, COLOR & PROFILE OF EAVE & RAKE COMPONENTS. G.C. TO PROVIDE MOCK-UPS.
3. UNVENTED ENCLOSED RAFTER ASSEMBLY: NO INTERIOR CLASS I VAPOR RETARDER SHALL BE INSTALLED ON THE CEILING SIDE
(ATTIC FLOOR) OF THE UNVENTED ATTIC ASSEMBLY OR ON THE CEILING SIDE OF THE UNVENTED ENCLOSED ROOF FRAMING
ASSEMBLY.
4. REF. WOOD OR WOODBASE PRODUCT NOTES ON FLOOR PLANS
1
A-5.0
1
A-5.0
2
A-5.0
2
A-5.0
S.Y.S.B.3' - 0"S.Y.S.B.3' - 0"F.Y.S.B.
9' - 0"3:123:123:12
6:12POOL
BELOW
REAR DECK
BELOW
1
2
3
2
2
4
45
5
6
6
6
6
6
3' - 1 1/2"3' - 9"3' - 8"5' - 1"3' - 1 1/2"1' - 1 1/4"
6' - 0"3:123:123:12
REFER TO A-2.3
REFER TO A-2.3
2 1/2"2 1/2"
2 1/2"2 1/2"2 1/2"2 1/2"2 1/2"2 1/2"
40.93' T.O. ROOF
HT. CERT. REQ.
40.88' T.O. ROOF
40.80' T.O. ROOF
HT. CERT. REQ.
HT. CERT. REQ.
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED, ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL THEN BE HELD HARMLESS AND ABSOLVED OF ANY LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
GENERAL NOTESA
B KEYNOTES
BRANDON ARCHITECTS
03-22-2022
ROOF PLANOCEAN FRONT POOL HOUSESMITH 507 LLC
1616 W. OCEAN FRONT,
NEWPORT BEACH , CA 92663
CDP SUBMITTAL
1616 W. OCEAN FRONT, NEWPORT
BEACH , CA 92663
A-3.0
**0000-2021**
ELIZABETH HANNA
1 STANDING SEAM METAL ROOFING - REF. MAT. SCHEDULE SHT. A-4.0
2 EXPOSED STEEL BEAM SIZE PER STRUCT. DWGS., PAINT AND SEAL AS REQ'D. - COORDINATE W/. INTERIOR.
3 STEEL TRELLIS, PAINT & SEAL AS SEL. - ARCH. TO APPV. - SIZE & CONN. PER STRUCT.
4 GUTTER - ALUMINUM W/. KYNAR FINISH, SHAPE AS SEL. - PROVIDE SHOP DWGS. TO ARCH.
5 DOWNSPOUT - ALUMINUM W/. KYNAR FINISH OR EQUIV. - AS SEL. (ARCH. TO APPROVE)
6
1/4" = 1'-0"1ARCHITECTURAL ROOF PLAN
NO. REVISION DATE
PA2022-067
SECOND FLOOR F.F.
21.09'
THIRD FLOOR F.F.
31.10'
ROOF PLATE
38.35'
ROOF PLATE
38.35'
FIRST FLOOR F.F.
12.50'
SECOND FLOOR PLATE
19.89'
THIRD FLOOR PLATE
29.90'
1
A-5.0
MAX. HT.
40.95'
MAX. HT.
40.95'
MAX. FLAT
35.95'
MAX. FLAT
35.95'
GRADE PLANE
11.95'
GRADE PLANE
11.95'
SECOND FLOOR T.O.S.
20.97'
THIRD FLOOR T.O.S.
30.98'
FIRST FLOOR T.O.S.
12.38'24' - 0"29' - 0"GARAGE FLOOR T.O.S.
10.08'
POOL DECK F.F.
32.28'
POOL DECK PLATE
31.08'
POOL DECK T.O.S.
32.16'
POOL STRUCTURE F.F.
25.44'
POOL STRUCTURE PLATE
23.81'
POOL STRUCTURE T.O.S.
25.31'
GARAGE FLOOR F.F.
10.21'
LOWER FIRST FLOOR F.F.
11.33'LOWER FIRST FLOOR T.O.S.
11.21'
POOL SERVICE F.F.
23.76'
POOL SERVICE PLATE
22.55'
POOL SERVICE T.O.S.
23.64'
POOL BRIDGE F.F.
28.44'POOL BRIDGE T.O.S.
28.31'
POOL BRIDGE PLATE
27.23'
LOWER FIRST FLOOR PLATE
10.21'
FIRST FLOOR PLATE
11.38'
PLPL
6
5
18
978
1617
22
1920
6
2324
10' - 0 1/8"9' - 7 5/8"1' - 3"7' - 3"1' - 2 1/2"8' - 9 5/8"1' - 2 1/2"8' - 6 5/8"1' - 1 1/2"3' - 10 1/8"3' - 0"1' - 8 1/8"11' - 3 1/8"1' - 2 1/2"2' - 7 5/8"1' - 2 1/2"3' - 5 5/8"1' - 2 1/2"10' - 0 5/8"1' - 1 1/2"1' - 2 1/2"5' - 7 5/8"1' - 7 1/2"11' - 3 3/4"4' - 8 1/8"SETBACKBALCONY ENCROACHMENT
3' - 0"
1
7
2
8
ABV. F.F.42" MIN.HD. HT.9' - 6"SILL HT.3' - 6"SILL HT.4' - 6"9
8
8
6
7
5 7
5 8
3
ABV. F.F.42" MIN.5
3
ABV. F.F.42" MIN.5
40.93'40.80'10
11
HD. HT.8' - 0"SILL HT.3' - 0"SILL HT.4' - 6"SILL HT.3' - 0"HD. HT.7' - 0"SILL HT.3' - 0"10
9
12
WINDOWS & DOORS:
AUTHORIZED DEALER (PRODUCTS LISTED BELOW)
SUPPLIER: ASSOCIATED BUILDING SUPPLY
ADDRESS: STONE MILL DESIGN CENTER 2915 RED HILL AVE., SUITE F104, COSTA MESA, CA 92626
CONTACT: JOE YOUNAN
PHONE: 949-872-3319
FAX: 206-666-2150
EMAIL: JYOUNAN@ABSSOCAL.COM
WEB: WWW.ASSOCIATEDBUILDINGSUPPLY.COM
ALUMINUM CLAD WINDOWS & PATIO DOORS
MANUFACTURER: JELD-WEN WINDOWS & DOORS
PRODUCT: CUSTOM COLLECTION
ADDRESS: 3250 LAKEPORT BLVD. P.O. BOX 1329; KLAMATH FALLS, OREGON 97601
PHONE:541-885-7412 OR 800-535-3936
FAX:541-884-3331
WEB:WWW.JELD-WEN.COM
MULTI SLIDE DOORS & STOREFRONT
MANUFACTURER: WESTERN WINDOW SYSTEMS
PRODUCT: SERIES 600 & STOREFRONT SYSTEMS
ADDRESS: 5621 S. 25TH ST., PHOENIX, AZ 85040
PHONE: 877.268.1300
WEB: WWW.WESTERNWINDOWSYSTEMS.COM
EXTERIOR STUCCO:
MANUFACTURER: MERLEX STUCCO
2911 ORANGE-OLIVE ROAD
ORANGE, CA 92865
P: 714.627.1700
COLOR: TBD
APPLICATION: THREE-COAT APPL., SMOOTH 7/8" W/. METAL LATH (DIAMOND OR EQUIV.)
BOARD FORMED CONCRETE TILE:
SUPPLIER: 2STONE DESIGNER CONCRETE INC.
TYPE: BOARD FORM VENEER
SIZE: TBD - ARCH TO APPROVE
COLOR: TBD - ARCH. TO APPROVE
FINISH: TBD - ARCH. TO APPROVE
METAL ROOFING: ( CLASS 'A' - NON REFLECTIVE)
PRODUCT: STANDING SEAM METAL ROOFING, ULTRA-COOL, CB-150
MANUFACTURER: CUSTOM-BILT METALS
COLOR: OLD TOWN GRAY, TO BE APPROVED BY ARCH. & OWNER (SOLAR REFLECTANCE 0.35, THERMAL EMITTANCE
0.83)
NOTES: USE CONTINUOUS 12" OR 16" PANS - VERIFY W/. ARCH. SIZE & LOC'N. OF SEAMS (NO TRANSVERSE SEAMS)
APPROVALS: ICC ESR-2048, CLASS 'A' ASSEMBLY
WEIGHT: APPX. 2 PSF.
GUTTERS:
MATERIAL: METAL - COPPER/ALUM. PAINTED KYNAR
SHAPE: HALF ROUND/SQUARE (5") (VERIFY W/. ARCH.)
GARAGE DOORS:
SUPPLIER: RANCH HOUSE DOORS
WEB: WWW.RANCHHOUSEDOORS.COM
STYLE: CUSTOM
MATERIAL: CUSTOM BUILT, WOOD & GLASS
WATERPROOF DECK MEMBRANE:
MFGR: TUFFLEX POLYMERS
ADDRESS: 10880 POPLAR AVE., FONTANA, CA
PHONE: 909.349.2016
WEB: WWW.TUFFLEXPOLYMERS.COM
CODE: ICC # ESR-2505
FLASHING & WEATHERSTRIPPING
PROVIDE CORROSION-RESISTANCE METAL FLASHING PER CRC FOR ALL EXTERIOR FLASHING, MIN. 24 GUAGE COPPER (16 OZ.)
SHEETS U.N.O. IN CRC OR MFGR. INSTALLATION GUIDELINES. ALL METAL IN CONTACTS TO BE OF SIMILAR TYPE TO AVOID
GALVANIC CORROSION. VERIFY W/. ARCHITECT ANY UNCONVENTIONAL ENVELOPE WATERPROOFING AREAS PRIOR TO INSTALLATION
1. FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT LABELS.
2. REF. ROOF PLAN (A-3.0) FOR ALL PLATE HTS. & RIDGE HTS.
ROOF PLATE
38.35'
ROOF PLATE
38.35'
FIRST FLOOR F.F.
12.50'
FIRST FLOOR F.F.
12.50'
2
A-5.0
MAX. HT.
40.95'
MAX. HT.
40.95'
MAX. FLAT
35.95'
MAX. FLAT
35.95'
GRADE PLANE
11.95'
GRADE PLANE
11.95'
FIRST FLOOR T.O.S.
12.38'
FIRST FLOOR T.O.S.
12.38'
POOL DECK F.F.
32.28'
POOL DECK F.F.
32.28'
POOL DECK PLATE
31.08'
POOL DECK PLATE
31.08'
POOL DECK T.O.S.
32.16'
POOL DECK T.O.S.
32.16'
POOL BRIDGE F.F.
28.44'
POOL BRIDGE F.F.
28.44'POOL BRIDGE T.O.S.
28.31'
POOL BRIDGE T.O.S.
28.31'
POOL BRIDGE PLATE
27.23'
POOL BRIDGE PLATE
27.23'
FIRST FLOOR PLATE
11.38'
FIRST FLOOR PLATE
11.38'
PL PL
29' - 0"MIN. ABV. F.F.3' - 6"11 10
19
3:12 3:12 3:12 3:12
3:123:12
40.80'40.93'40.63'
1
2
3
ABV. F.F.42" MIN.ABV. F.F.42" MIN.24' - 0"15' - 11 1/4"3' - 10 1/8"1' - 1 1/2"14' - 8 3/4"1' - 2 1/2" 2' - 7 5/8" 1' - 2 1/2"1' - 0"1 1/2"1' - 1"1 1/2"1' - 1"1 1/2"HT. CERT. REQ'D HT. CERT. REQ'D HT. CERT. REQ'D
4
5
1
1
6
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED, ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL THEN BE HELD HARMLESS AND ABSOLVED OF ANY LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
MATERIAL SPECIFICATIONSA
KEYNOTESC
GENERAL NOTESB
BRANDON ARCHITECTS
03-22-2022
EXTERIOR
ELEVATIONSOCEAN FRONT POOL HOUSESMITH 507 LLC
1616 W. OCEAN FRONT,
NEWPORT BEACH , CA 92663
CDP SUBMITTAL
1616 W. OCEAN FRONT, NEWPORT
BEACH , CA 92663
A-4.0
**0000-2021**
ELIZABETH HANNA
1/4" = 1'-0"2NORTH ELEVATION
1 STRUCT. STEEL COLUMN - REF. STRUCT. DWGS. & PROVIDE SHOP DWGS. FOR ARCH. & ENGINEER APPV. PRIOR TO FAB.
2 STRUCT. BEAM - SIZE & LOC'N. PER STRUCT. DWGS
3 EXTERIOR GUARDRAIL - MIN. 42" HEIGHT - 4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
4 STUCCO FINISH - MIN. 7/8" THK. W/. DIA. LATH, COLOR AS SEL., REF. MAT. SCHEDULE A-4.0
5 STUCCO FINISH - MIN. 7/8" THK. W/. DIA. LATH, COLOR AS SEL., REF. MAT. SCHEDULE A-4.0
6 EXTERIOR GLASS GUARDRAIL - TEMPERED & LAMINATED - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
7 BOARD FORM CONCRETE - REF. STRUCT.
8 CUSTOM WOOD SCREEN, PAINT & SEAL AS SEL. - ARCH. TO APPV. - SIZE & CONN. PER STRUCT.
9 (N.) WOOD GATE - AS SELECTED. PAINT TO MATCH WOOD PANEL SIDING SCREEN. REF. MATERIAL SCHEDULE SHT A-4.0
10 STANDING SEAM METAL ROOFING - REF. MAT. SCHEDULE SHT. A-4.0
11 EXPOSED STEEL BEAM SIZE PER STRUCT. DWGS., PAINT AND SEAL AS REQ'D. - COORDINATE W/. INTERIOR.
12 STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT
CANDLE (CBC 1205.4) REF. DTL. 3/AD-1
NO. REVISION DATE
1/4" = 1'-0"1WEST ELEVATION
PA2022-067
WINDOWS & DOORS:
AUTHORIZED DEALER (PRODUCTS LISTED BELOW)
SUPPLIER: ASSOCIATED BUILDING SUPPLY
ADDRESS: STONE MILL DESIGN CENTER 2915 RED HILL AVE., SUITE F104, COSTA MESA, CA 92626
CONTACT: JOE YOUNAN
PHONE: 949-872-3319
FAX: 206-666-2150
EMAIL: JYOUNAN@ABSSOCAL.COM
WEB: WWW.ASSOCIATEDBUILDINGSUPPLY.COM
ALUMINUM CLAD WINDOWS & PATIO DOORS
MANUFACTURER: JELD-WEN WINDOWS & DOORS
PRODUCT: CUSTOM COLLECTION
ADDRESS: 3250 LAKEPORT BLVD. P.O. BOX 1329; KLAMATH FALLS, OREGON 97601
PHONE:541-885-7412 OR 800-535-3936
FAX:541-884-3331
WEB:WWW.JELD-WEN.COM
MULTI SLIDE DOORS & STOREFRONT
MANUFACTURER: WESTERN WINDOW SYSTEMS
PRODUCT: SERIES 600 & STOREFRONT SYSTEMS
ADDRESS: 5621 S. 25TH ST., PHOENIX, AZ 85040
PHONE: 877.268.1300
WEB: WWW.WESTERNWINDOWSYSTEMS.COM
EXTERIOR STUCCO:
MANUFACTURER: MERLEX STUCCO
2911 ORANGE-OLIVE ROAD
ORANGE, CA 92865
P: 714.627.1700
COLOR: TBD
APPLICATION: THREE-COAT APPL., SMOOTH 7/8" W/. METAL LATH (DIAMOND OR EQUIV.)
BOARD FORMED CONCRETE TILE:
SUPPLIER: 2STONE DESIGNER CONCRETE INC.
TYPE: BOARD FORM VENEER
SIZE: TBD - ARCH TO APPROVE
COLOR: TBD - ARCH. TO APPROVE
FINISH: TBD - ARCH. TO APPROVE
METAL ROOFING: ( CLASS 'A' - NON REFLECTIVE)
PRODUCT: STANDING SEAM METAL ROOFING, ULTRA-COOL, CB-150
MANUFACTURER: CUSTOM-BILT METALS
COLOR: OLD TOWN GRAY, TO BE APPROVED BY ARCH. & OWNER (SOLAR REFLECTANCE 0.35, THERMAL EMITTANCE
0.83)
NOTES: USE CONTINUOUS 12" OR 16" PANS - VERIFY W/. ARCH. SIZE & LOC'N. OF SEAMS (NO TRANSVERSE SEAMS)
APPROVALS: ICC ESR-2048, CLASS 'A' ASSEMBLY
WEIGHT: APPX. 2 PSF.
GUTTERS:
MATERIAL: METAL - COPPER/ALUM. PAINTED KYNAR
SHAPE: HALF ROUND/SQUARE (5") (VERIFY W/. ARCH.)
GARAGE DOORS:
SUPPLIER: RANCH HOUSE DOORS
WEB: WWW.RANCHHOUSEDOORS.COM
STYLE: CUSTOM
MATERIAL: CUSTOM BUILT, WOOD & GLASS
WATERPROOF DECK MEMBRANE:
MFGR: TUFFLEX POLYMERS
ADDRESS: 10880 POPLAR AVE., FONTANA, CA
PHONE: 909.349.2016
WEB: WWW.TUFFLEXPOLYMERS.COM
CODE: ICC # ESR-2505
FLASHING & WEATHERSTRIPPING
PROVIDE CORROSION-RESISTANCE METAL FLASHING PER CRC FOR ALL EXTERIOR FLASHING, MIN. 24 GUAGE COPPER (16 OZ.)
SHEETS U.N.O. IN CRC OR MFGR. INSTALLATION GUIDELINES. ALL METAL IN CONTACTS TO BE OF SIMILAR TYPE TO AVOID
GALVANIC CORROSION. VERIFY W/. ARCHITECT ANY UNCONVENTIONAL ENVELOPE WATERPROOFING AREAS PRIOR TO INSTALLATION
1. FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT LABELS.
2. REF. ROOF PLAN (A-3.0) FOR ALL PLATE HTS. & RIDGE HTS.
SECOND FLOOR F.F.
21.09'
THIRD FLOOR F.F.
31.10'
ROOF PLATE
38.35'
ROOF PLATE
38.35'
FIRST FLOOR F.F.
12.50'
SECOND FLOOR PLATE
19.89'
THIRD FLOOR PLATE
29.90'
1
A-5.0
MAX. HT.
40.95'
MAX. HT.
40.95'
MAX. FLAT
35.95'
MAX. FLAT
35.95'
GRADE PLANE
11.95'
GRADE PLANE
11.95'
SECOND FLOOR T.O.S.
20.97'
THIRD FLOOR T.O.S.
30.98'
FIRST FLOOR T.O.S.
12.38'
GARAGE FLOOR T.O.S.
10.08'
POOL DECK F.F.
32.28'
POOL DECK PLATE
31.08'
POOL DECK T.O.S.
32.16'
POOL STRUCTURE F.F.
25.44'
POOL STRUCTURE PLATE
23.81'
POOL STRUCTURE T.O.S.
25.31'
GARAGE FLOOR F.F.
10.21'
LOWER FIRST FLOOR F.F.
11.33'
LOWER FIRST FLOOR T.O.S.
11.21'
POOL SERVICE F.F.
23.76'
POOL SERVICE PLATE
22.55'
POOL SERVICE T.O.S.
23.64'
POOL BRIDGE F.F.
28.44'POOL BRIDGE T.O.S.
28.31'POOL BRIDGE PLATE
27.23'
LOWER FIRST FLOOR PLATE
10.21'
FIRST FLOOR PLATE
11.38'
PL PL
11' - 3 1/8"1' - 8 1/8" 3' - 0"3' - 10 1/8"6' - 2 3/8"29' - 0"MIN. ABV. F.F.3' - 6"1' - 1 1/2"9' - 9 1/8"10' - 0 1/8"7' - 4 1/2"29' - 0"1 1/2"1' - 0"1 1/2"7 3/8"7' - 11 1/4"1' - 1" 1 1/2"8' - 9 5/8"1' - 1" 1 1/2"7' - 3"11 1012
3
13
4
15
21
14
2526
3:12
24' - 0"1
2
3
2
24
5ABV. F.F.42" MIN.40.88'40.80'
26
5
5 7
8
9
3
32
211
4 SETBACK2
ABV. LANDING3' - 0"ABV. LANDING3' - 0"ABV. LANDING3' - 1 1/2"HD. HT.8' - 6"HD. HT.8' - 0"HD. HT.7' - 0"HD. HT.10' - 0"SILL HT.4' - 0"BALCONY ENCROACHMENT
5' - 0 3/4"
SECOND FLOOR F.F.
21.09'
THIRD FLOOR F.F.
31.10'
ROOF PLATE
38.35'
SECOND FLOOR PLATE
19.89'
THIRD FLOOR PLATE
29.90'
2
A-5.0
MAX. HT.
40.95'
MAX. FLAT
35.95'
GRADE PLANE
11.95'24' - 0"29' - 0"SECOND FLOOR T.O.S.
20.97'
THIRD FLOOR T.O.S.
30.98'
GARAGE FLOOR T.O.S.
10.08'
GARAGE FLOOR F.F.
10.21'
PLPL
1 1/2"1' - 8 7/8"7' - 11 1/4"1' - 1" 1 1/2"8' - 9 5/8"1' - 1" 1 1/2" 7' - 3"
3:12
15
15
68
21
5 ABV. F.F.42" MIN.ABV. F.F.42" MIN.9' - 8 1/8"10' - 10 5/8"10' - 0 1/8"3
2
2
2
2
3:12 3:12
40.93'40.88'
4
8 4
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED, ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL THEN BE HELD HARMLESS AND ABSOLVED OF ANY LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
MATERIAL SPECIFICATIONSA
KEYNOTESC
GENERAL NOTESB
BRANDON ARCHITECTS
03-22-2022
EXTERIOR
ELEVATIONSOCEAN FRONT POOL HOUSESMITH 507 LLC
1616 W. OCEAN FRONT,
NEWPORT BEACH , CA 92663
CDP SUBMITTAL
1616 W. OCEAN FRONT, NEWPORT
BEACH , CA 92663
A-4.1
**0000-2021**
ELIZABETH HANNA
1 RECESSED MAIN SERVICE PANEL, 400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION)
2 STUCCO FINISH - MIN. 7/8" THK. W/. DIA. LATH, COLOR AS SEL., REF. MAT. SCHEDULE A-4.0
3 BOARD FORM CONCRETE - REF. STRUCT.
4 EXTERIOR GUARDRAIL - MIN. 42" HEIGHT - 4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
5 CUSTOM WOOD SCREEN, PAINT & SEAL AS SEL. - ARCH. TO APPV. - SIZE & CONN. PER STRUCT.
6 EXTERIOR GLASS GUARDRAIL - TEMPERED & LAMINATED - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
7
8 STRUCT. STEEL COLUMN - REF. STRUCT. DWGS. & PROVIDE SHOP DWGS. FOR ARCH. & ENGINEER APPV. PRIOR TO FAB.
9 STRUCT. BEAM - SIZE & LOC'N. PER STRUCT. DWGS
NO. REVISION DATE
1/4" = 1'-0"2SOUTH ELEVATION
1/4" = 1'-0"1EAST ELEVATION
PA2022-067
SECOND FLOOR F.F.
21.09'
THIRD FLOOR F.F.
31.10'
THIRD FLOOR F.F.
31.10'
ROOF PLATE
38.35'
ROOF PLATE
38.35'
FIRST FLOOR F.F.
12.50'
SECOND FLOOR PLATE
19.89'
THIRD FLOOR PLATE
29.90'
THIRD FLOOR PLATE
29.90'
2
A-5.0
MAX. HT.
40.95'
MAX. HT.
40.95'
MAX. FLAT
35.95'
MAX. FLAT
35.95'
SECOND FLOOR T.O.S.
20.97'
THIRD FLOOR T.O.S.
30.98'
THIRD FLOOR T.O.S.
30.98'
FIRST FLOOR T.O.S.
12.38'LOWER FIRST FLOOR F.F.
11.33'
LOWER FIRST FLOOR T.O.S.
11.21'
POOL SERVICE F.F.
23.76'
POOL SERVICE PLATE
22.55'
POOL SERVICE T.O.S.
23.64'
FOYER SAND ROOM
BEDROOM #2
ENTRY
LOUNGE DECK
MECHANICAL
LOWER FIRST FLOOR PLATE
10.21'
FIRST FLOOR PLATE
11.38'
PL PL
4' - 9 5/8"4' - 9 5/8"9' - 9 1/8"10' - 0 1/8"1' - 1 1/2"8' - 6 5/8"1' - 2 1/2"8' - 9 5/8"1' - 2 1/2"7' - 3"1' - 1 1/2"10' - 0 5/8"1' - 2 1/2"6' - 1 5/8"1' - 2 1/2"7' - 3"11' - 3 1/8"7' - 4 1/8"3:12 3:12 3:12 3:12
3:123:12
19
83 CLR.8' - 6"CLR.10' - 0"CLR.9' - 6"CLR.8' - 9"CLR.6' - 1 5/8"7
2% MIN.2% MIN.
8
1
9
4
4
EXTERIOR WALL:
2 x 4 CONST.:R-13 MIN.
2 x 6 CONST. OR LARGER: R-20 MIN.
RAISED FLOOR:R-30 MIN.
ROOF:R-30
NOTES:
1. REF. T-24 REPORT FOR MORE INFORMATION
2. PROVIDE BID FOR INSULATION OF ENTIRE HOME
*TOTAL R-VALUE INCLUDING THE RIDGID AND SPRAYED AIR-IMPERMEABLE INSULATION WHERE OCCURS FOR UNVENTED ASSEMBLY
**ALWAYS CHECK THIS INSULATION SCHEDULE FOR CONFORMANCE WITH THE TITLE 24 REPORT**
FIREBLOCKING AND DRAFTSTOPPING SHALL BE INSTALLED TO CUT OFF ALL CONCEALED DRAFT OPENINGS (BOTH VERTICAL AND HORIZONTAL) AND SHALL FORM AN EFFECTIVE BARRIER BETWEEN FLOORS, BETWEEN A TOP STORY AND A ROOF OR ATTIC SPACE,
AND SHALL SUBDIVIDE ATTIC SPACES, CONCEALED ROOF SPACES AND FLOOR-CEILING ASSEMBLIES. THE INTEGRITY OF ALL FIRE
BLOCKS AND DRAFT STOPS SHALL BE MAINTAINED.
FIRE BLOCKS
FIREBLOCKING SHALL BE PROVIDED IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES, AT
THE CEILING AND FLOOR LEVELS AND AT 10-FOOT INTERVALS BOTH VERTICAL AND HORIZONTAL.
FIRE BLOCK CONSTRUCTION
FIREBLOCKING SHALL CONSIST OF 2 INCHES NOMINAL LUMBER. FIRE BLOCKS MAY ALSO BE OF GYPSUM BOARD, CEMENT FIBER
BOARD, BATTS OR BLANKETS OF MINERAL OR GLASS FIBER, OR OTHER APPROVED MATERIALS INSTALLED IN SUCH A MANNER AS
TO BE SECURELY RETAINED IN PLACE. LOOSE-FILL INSULATION MATERIAL SHALL NOT BE USED.
WALLS HAVING PARALLEL OR STAGGERED STUDS FOR SOUND-TRANSMISSION CONTROL SHALL HAVE FIRE BLOCKS OF BATTS OR
BLANKETS OF MINERAL OR GLASS FIBER OR OTHER APPROVED FLEXIBLE MATERIALS.
DRAFT STOPS
DRAFTSTOPPING SHALL BE PROVIDED IN THE LOCATIONS SET FORTH IN THIS SECTION.
FLOOR-CEILING ASSEMBLIES
DRAFT STOPS SHALL BE INSTALLED IN FLOOR-CEILING ASSEMBLIES OF THE BUILDING. SUCH DRAFT STOPS SHALL BE IN LINE WITH
WALLS SEPARATING INDIVIDUAL DWELLING UNITS FROM EACH OTHER AND FROM OTHER AREAS.
ATTICS
DRAFT STOPS SHALL BE INSTALLED IN THE ATTICS, MANSARDS, OVERHANGS, FALSE FRONTS SET OUT FROM WALLS AND SIMILAR
CONCEALED SPACES OF THIS BUILDING. SUCH DRAFT STOPS SHALL BE ABOVE AND IN LINE WITH THE WALLS SEPARATING
INDIVIDUAL DWELLING UNITS FROM EACH OTHER AND FROM OTHER USES.
DRAFT STOP CONSTRUCTION
DRAFTSTOPPING MATERIALS SHALL NOT BE LESS THAN ½-INCH GYPSUM BOARD, 3/8-INCH WOOD STRUCTURAL PANEL, 3/8-INCH
TYPE 2-M PARTICLEBOARD OR OTHER APPROVED MATERIALS ADEQUATELY SUPPORTED.
OPENINGS IN THE PARTITIONS SHALL BE PROTECTED BY SELF-CLOSING DOORS WITH AUTOMATIC LATCHES CONSTRUCTED AS
REQUIRED FOR THE PARTITIONS.
ROOM TAGROOM NAME
1
A-5.0
1 1
?
1
1
ELEVATION / SECTION INDICATOR
AD-1.0
1 CALL-OUT TAG
10.00'SPOT ELEVATION
KEYNOTE TAG
REVISION TAG
DOOR / WINDOW / WINDOW WALL TAG
FIRE RATED CEILING ASS'Y - REF. DTLS. 7/AD-1.0
1-HR RATED INT CONDITION - REF. DTLS. 7/AD-1.0
1-HR RATED EXT CONDITION - REF. DTLS. 7/AD-1.0
CONCRETE WALL/PODIUM DECK - PER STRUCT. REF. STRUCT DWGS. – FOR SLAB ON
GRADE PROVIDE BASE PER R506.2.2 AND VAPOR RETARDER PER R506.2.3 W/.
CAPILLARY BREAK
INSULATED BUILDING ENVELOPE - 2X STUDS PER PLANS, SEE DIMENSION PLANS FOR
MORE INFO – INSULATION PER INSULATION SCHEDULE AND T-24 ENERGY REPORTS
UNVENTED ROOF ASSEMBLY ROOF FRAMING - PER STRUCT., REF. STRUCT.
DWGS. – UNVENTED ASSEMBLY TO COMPLY W/. SECTION R806.5 OF CRC, AIR-
IMPERMEABLE VALUE PER TABLE R806.5 OF CRC
VENTED ROOF ASSEMBLY ROOF FRAMING - PER STRUCT., REF. STRUCT. DWGS. –
PROVIDE CROSS VENTILATION PER SECTION R806 OF CRC, SEE ROOF PLAN SHEET A-3.0
FOR ATTIC VENT CALC AND MORE INFO
SECOND FLOOR F.F.
21.09'
THIRD FLOOR F.F.
31.10'
ROOF PLATE
38.35'
ROOF PLATE
38.35'
FIRST FLOOR F.F.
12.50'
SECOND FLOOR PLATE
19.89'
THIRD FLOOR PLATE
29.90'
1
A-5.0
MAX. HT.
40.95'
MAX. HT.
40.95'
MAX. FLAT
35.95'
MAX. FLAT
35.95'
SECOND FLOOR T.O.S.
20.97'
THIRD FLOOR T.O.S.
30.98'
FIRST FLOOR T.O.S.
12.38'
GARAGE FLOOR T.O.S.
10.08'2' - 7 1/8"7' - 3"1' - 2 1/2"8' - 9 5/8"1' - 2 1/2"8' - 6 5/8"POOL DECK F.F.
32.28'
POOL DECK PLATE
31.08'
POOL DECK T.O.S.
32.16'
POOL STRUCTURE F.F.
25.44'
POOL STRUCTURE PLATE
23.81'
POOL STRUCTURE T.O.S.
25.31'CLR.8' - 6"LOWER FIRST FLOOR F.F.
11.33'
LOWER FIRST FLOOR T.O.S.
11.21'
POOL SERVICE F.F.
23.76'
POOL SERVICE PLATE
22.55'
POOL SERVICE T.O.S.
23.64'
POOL BRIDGE F.F.
28.44'CLR.7' - 4"POOL BRIDGE T.O.S.
28.31'
POOL BRIDGE PLATE
27.23'
GREAT ROOM
FOYER
2-CAR GARAGE
MASTER SUITE
BONUS ROOM
POOL
KITCHEN
SPA
LOUNGE DECK DECK
LOWER FIRST FLOOR PLATE
10.21'TYP.7 3/8"7' - 4 1/2"10' - 0 1/8"9' - 9 1/8"1' - 1 1/2"ABV. F.F.42" MIN.ABV. F.F.42" MIN.ABV. F.F.42" MIN.CLR.10' - 4 3/8"CLR.13' - 10 5/8"STAIR LANDING3' - 0"4
4
18
13
12
22 21 20
3' - 10 1/8"4' - 8 1/8"1' - 2 1/2"10' - 0 5/8"6' - 10 1/8"1' - 7 1/2"11' - 3 3/4"1' - 2 1/2"7' - 3 3/4"1 1/2"1' - 1"1 1/2"1' - 1"1 1/2"1' - 1"CLR.6' - 10 1/8"1
CLR.10' - 0"101112
112
2
3
MECH.TYP.7"CLR.10' - 0"2% MIN.2% MIN.ABV. F.F.42" MIN.TYP.7 1/2"TYP.7 1/2"TYP.
11"
SLOPE PER CIVIL CLR.8' - 8 7/8"CLR.8' - 9"26 25
ABV. F.F.42" MIN.2
2
3
4
ABV. F.F.42" MIN.5
6
PL
PL
SETBACKBALCONY ENCROACHMENT
3' - 0"
2
4
3:12 3:12
2% MIN.
2% MIN.2' - 3 1/2"DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED, ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL THEN BE HELD HARMLESS AND ABSOLVED OF ANY LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
FIRE-BLOCKING & DRAFT STOP NOTESA
INSULATION SCHEDULEB
ANNOTATION LEGENDC
KEYNOTESD
BRANDON ARCHITECTS
03-22-2022
BUILDING SECTIONSOCEAN FRONT POOL HOUSESMITH 507 LLC
1616 W. OCEAN FRONT,
NEWPORT BEACH , CA 92663
CDP SUBMITTAL
1616 W. OCEAN FRONT, NEWPORT
BEACH , CA 92663
A-5.0
**0000-2021**
ELIZABETH HANNA
1/4" = 1'-0"1TRANSVERSE SECTION
1 EXTERIOR GLASS GUARDRAIL - TEMPERED & LAMINATED - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
2 EXTERIOR GUARDRAIL - MIN. 42" HEIGHT - 4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
3 STRUCT. STEEL COLUMN - REF. STRUCT. DWGS. & PROVIDE SHOP DWGS. FOR ARCH. & ENGINEER APPV. PRIOR TO FAB.
4 CUSTOM WOOD SCREEN, PAINT & SEAL AS SEL. - ARCH. TO APPV. - SIZE & CONN. PER STRUCT.
5 CONCRETE SLAB ON GRADE - REF. STRUCT.
6 FLOOR JOISTS - REF. STRUCT.
7 STUCCO FINISH - MIN. 7/8" THK. W/. DIA. LATH, COLOR AS SEL., REF. MAT. SCHEDULE A-4.0
8 EXPOSED STRUCTURAL STEEL COLUMN TO SUPPORT STEEL WIRE TRELLIS, SIZE PER STRUCT.; PAINT & SEAL AS SEL. (ARCH.
TO APPV.)
9 EXPOSED STEEL BEAM SIZE PER STRUCT. DWGS., PAINT AND SEAL AS REQ'D. - COORDINATE W/. INTERIOR.
NO. REVISION DATE
1/4" = 1'-0"2LONGITUDINAL SECTION
PA2022-067