Loading...
HomeMy WebLinkAboutPA2022-063_20220331_Facility Plans_34x22 Project Description for RNG Facility 8 www.scsengineers.com Appendix B Facility Plans PA2022-063 PA2022-063 34250-2001-D-PID POINT OF RECEIPT COYOTE CANYON P&ID FROM BIOFUELS NB D.L. 50 PSIG M.A.O.P 46 PSIG MOP 40 PSIG MIN. OP 16 PSIG 3" NO 1"1"TIT TE TW 1" AI 4-20 mA3" NO 1/2"1/2"1/2"HV 1/2"1/2"PIC 1/4" PCV 1/4" PCV 1/4" 1/4"1/4"DEDEDO NOTE 4 DO NOTE 5 3/4"3" NO 3" NC 3/4"FE UIT 1/2"1/2"TF1 TW TE TW RTD 1" 1" 1" RS-485 N-TRON ETHERNET 3/4"3/4"AE SAMPLER 1/2" DO J6 1/2"1/2"HV PIC 1/2"PCV SERVICE 3" HV PIC 1/2"1/2"1/2"1/2"SENSE LINESENSE LINE1/4" 1/4"1/4"1/4"PCV1/4"PCV1/4"1/4"1/4"1/4"1/4"PCV PCV 1/4"1/4"4"1/2"3/4"1/2"1/2"4" NO 3/4"RADIO SPP-1 RS 232 GAS CONTROL CELLULAR CELLULAR SPP-1 SPP-1 CUSTOMER MODBUS TCP ETHERNET FEI PCV → 02 PI →PCV UIT 02SPP-1 RS-485 AI 4-20 mA DI DI UIT H2S 4-20 mAAI → PCV SPP-1 UIT NGC N-TRON DI ETHERNET → FCV RS-485 UIT TF1 RS-485 DI DI DI DI HELIUM PLS PLS CAL SAMPLE GAS 2"2"2"2"1/2"1/2"2"LI 2"2"2"1/2"1/2"LI V-100 LIT LIT AI LI H4-20 mAAILIH4-20 mA1" 2"1"1/2"1/2"PDIT 1/4"1/4"1/4"NC PI1/4" AI PDI H 4-20 mA4" 3/4"3"NO2"1"LOPSV 1/4" 1"3"NO4" 3/4" 1/2"1/2" 3" NC1/4"3"1/4"1/2"3" NO 3/4"SUPPLY TO PUMP& EXPANSION LINEODORANT INJECTION1/4"PCV LOPSV LOPSV PSV LOAI RS485DI DI RS485AI HV COYOTE CANYON * XCOM XCOM 3" 4"x3" LEGEND & PRESSURE BLOCK RETURN LINE 102 102 105 101 104 100 100 101 100 101 103 101 100 100100 100 100 100 100A 100B 001 101 101 101 102 100 100 101 101 100 100 100 101 101B 101A 103 101A 101B 101 102A 102B 102 102101 102 1063/4"2"CORROSION COUPON ODORANT TAP 89395.000 8"x4" 4"x3" D.L. XXX PSIG M.A.O.P XXX PSIG MOP XXX PSIG MIN.OP XXX PSIG 4"x3"A. JACKSON 09/17/21 D. NGUYEN 09/17/21 I. GHANEM 09/17/21 S. LY 09/17/21 P. PATEL 09/17/21 OVER PRESSUREPROTECTION HOLD XX' OD x XX' S/S XXX XXX XXX FILTER SEPARATOR Cu Ft/Hr. V-100 PSIG °F SIZE: CAPACITY: DESIGN: GALLONS ODORANT INJECTION SYSTEM XXX MODEL: NJEX 6302 CAPACITY:3/4"1/4" STORAGE TANK PCV 101 MONITOR 3"3"TO #21027848 * 53% ** 60% PA2022-063 V-100 YZ ODORIZER INST.CABINETINST.CABINET 12' x 8'ANALYZERSHELTER 10' x 8'ELECTRICALSHELTER TP XX NEW 8"PIPELINE POINT OF RECEIPT FOR PLOT PLAN SEE DWG: 2450-3002-D-PIP EXISTING 8" SERVICE LINE FUTURE AT&T BACKUP GENERATOR NEW 8'x11' T-MOBILE EQUIPMENT ENCLOSURE NEW VERIZON & T-MOBILE MONOPOLE NEW 8'x10' VERIZON GENERATOR ENCLOSUREEXISTING UNDERGROUND LINES (TYP.) NEW UNDERGROUND COAX JOINT TRENCH EXISTING CONDUIT TRENCH SITE LIMITS PA2022-063 NOTES: 1. ALL DIMENSIONS AND ELEVATIONS ARE IN FEET AND INCHES. ISSUED FOR 30% REVIEW 0 5'10' SCALE: 3/16" = 1'-0"PLANTN 6'-0" 3'-6"75'-0"15'-6"15'-6"15'-0"SLIDING DOOR29'-6"60'-0"10' x 8'ELECTRICALSHELTER 12' x 8' ANALYZERSHELTER INST.CABINET INST.CABINET YZ ODORIZER 2'-6" 7'-0" V-100 16'-10" PCV 102 PCV 101 FE 101 OPP 100 2 TP 1 TP 3 TP 100'-0" 89395.000 POINT OF RECEIPTBIOME RULE 45 - COYOTE CANYONPLOT PLAN 34250-3002-D-PIP G. CASILLAS 09/20/21 G. CASILLAS 09/20/21 B. KIKAWA 09/23/21 P. DISOMMA 09/23/21 S. LY 3/16" = 1'-0"89395.000 *BDWG CLASS: DWG DIST: SCALE: DRAWINGNUMBER:REVREVNODRAWN CHK'D ENG FILE NOPROJAPVSCGENGAPV DESCRIPTIONDATE WOA BY DATE SCG ENG APV: PROJ APV: CHECKED: DRAWN: DESIGNED: ENG FILE NO: WOA: 20662 NEWPORT BEACH DR.NEWPORT BEACH A 09/23/21 GKC BDK PD SQL * ISSUED FOR 10% REVIEW B 10/15/21 GKC BDK PD SQL ISSUED FOR 30% REVIEW*89395.000 PA2022-063