Loading...
HomeMy WebLinkAboutPV2022-001 - Calcsp. ou -001 �{�01 0f' 144 Or. /�nGF Version #94.3 - 2 February 14, 2022 Nb. S 5185 j RE: CERTIFICATION LETTER C Exp 1'2/31/22sTq� Project'Job # 92621641 OF Project Address: Cheng Residence 4701 Cortland Dr - "STR ONLY" Newport Beach, CA 92625 ADigitally sign Abe Da by De p6e oevera / AHJ Newport Beach i Date;2022.02.14 Vera ' 11:50A2-08.00' SC Office Irvine BUILDING VISION Design Criteria: - Applicable Codes = 2019 CEBC/CBC/CRC, ASCE 7-16, and 2018 NDS - Risk Category = II02/15/2022 - Wind Speed = 110 mph (3-s Gust - Vult), Exposure Category C, Partially/Fully Enclosed Method - Ground/Roof Snow Load = 0 psf - MP1: Roof DL = 7.5 psf, Roof LL = 20 psf - MP2: Roof DL = 7.5 psf, Roof LL = 20 psf - MP3: Roof DL = 7.5 psf, Roof LL = 20 psf BY: Y.T. - MP4: Roof DL = 7.5 psf, Roof LL = 20 psf - MP6: Roof DL = 7.5 psf, Roof LL = 20 psf - MP7: Roof DL = 7.5 psf, Roof LL = 20 psf - MIPS: Roof DL = 7.5 psf, Roof LL = 20 psf Per Section 1613.1, W -(PV)/ W -(exist roof) = 5.5%, Increase Seismic Shear Load < 10%, -> [OK] To Whom It May Concern, Ajobsite survey of the existing framing system of the address indicated above was performed by a site survey team from Tesla. Structural evaluation was based on site observations and the design criteria listed above. Based on this evaluation, I certify that the alteration to the existing structure by installation of the PV system meets the prescriptive compliance requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally, I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the referenced codes for loading. The PV assembly hardware specifications are contained in the plans/docs submitted for approval. Sincerely Abe De Vera, PE, SE Structural Engineer Phone: 888.765.2489, x57526 Email: adeveraPtesla.com T - 5 L n 'At a 22 BUILDING DIVISION APR - 6 2022 BY E.S. Tesla, Inc. Version #94.3.2 16" ' 16" 41 NA 16 9 41 NA L— n 1 41" � TV 9 16" 9 9.. Tesla, Inc. Note: Seismic base shear is directiy proportional to rooT weiy"L. Zone (a) = 10.0 ft. per 3asf/ lbs = 1.15, YA= u.bu sf Portrait -Portrait _ - - NA Portrait NA - Trib -. NA W -PV NA ._ ' T -actual '; - - T -allow NA nra NA 7 psf Plum 9 6 176 Psfsf .,. Y-Y:,Katters -... e i.,.rav cieekMountT"' STRUCTURE,ANALYSIS LOADING SUMMARY AND MEMBER CHECK MP6 xa�"f x etMembe� 4oadingSurrlm"efY� ,4, :k�a Bopf ;P.,itcli s'�'��'�3!�2�1��# :tea ��lni>ial PttrJfAAlTlstm S45t Pw1/�reas Roof Dead Load DL 7.5 psf x 1.04 7.8 psf 7.8 psf PV -Dead Load ' , PN -DL. 3.0 psf: 'x 1.04 Roof Live Load RLL 20.0 psf x 1.00 20.0 psf Snow Load } - 'SLf Total Load (Governing,LC TL 27.8 psf 10.9 psf Notes: 1. ps = Cs'pf; Cs -roof, Cs -pv per AJUL r Lrigure 1.4-11, c. Pi - u. 1 k—I k-) I-, re ater Width (a) = Iu.0 R. >tandoff Spacing Landscap - 3artilever , „ Landscap ._..,._.____.. uration Landscap aulAry Area(Interipr) _ Tri6 _ , read Load W-PV ,atStandoff (Intarior) _T-actual of Standoff T-allow 11 nd/ca aci Interior DCR':. Standoff Spacing Portrait Cantilever Portrai -: T -actual T -allow DCR STRUCTURE ANALYSIS - LOADING SUMMARY ANp MEMBER,CHECK MP8 Notes: 1. ps = Cs'pf; Cs -roof, Cs -pv per ASCE 7 [Figure 7.4-1]; 2. pf = 0.7 (Ce) (Ct) (Is) pg ; Ce=0.9, Ct=1.1, Is= 1.0; m . N,[ipgf;P,ifch. Roof Dead Load DL 7.5 psf x 1.04 7.8 psf 7.8 psf PV_Dead'.Load , - .PV -DL ' 3.0 psf,,,, . ' x' 1 04 7 _','3.1 psf Roof Live Load - RLL 20.0 psf x 1.00 20.0 psf Snow, L'bad,` SL' Tota[ Load (Governing LC) Total ".TL 27.8-psf _ 1IM9 psf. - Notes: 1. ps = Cs'pf; Cs -roof, Cs -pv per ASCE 7 [Figure 7.4-1]; 2. pf = 0.7 (Ce) (Ct) (Is) pg ; Ce=0.9, Ct=1.1, Is= 1.0; ZEP RARQ E,DESIGN CALCULATIONS - MP8 Y -Y Rafters' 1..`. Ext. Pressure Coefficient (Up) GCp (Up) 1 27 rig. 3032ueraoreGTNe Ext. Pressure Coeffc e.(Down); GCp (Dawn) ", 0 55 A' , !4 10 3-2NeiaorFasnxsaa' Design Wind Pressure p p = qh (yE) (ya) (GCp); yE = 1.15, yA = 0.60 Equation 29.4-7 Wind Pressure Up (Design l UIt) rpp,pt -13,1 -21.7 psf_ Max Stantloff, Tributary Area (interior) _ Wind Pressure Down (Design I Ult . n 9.6 116 psf PV Assembly Dead Load Notes: 1. yE = Array Edge Factor and yA = Solar Panel Pressure Equalization Factor per SEAoC PV2-2017 A , ..._.,_. u '7', 7 .,N Wind Zone Perimeter Width (a) = 10.0 ft. "'�?Dtreron� y� N11 .,Dre ro: Max Allowable Standoff Spacing Landscape 16" 41" Max Allowable Cantilever Lan dscape9" _ NA Standoff Couration nfi Landscape Not -Staggered Max Stantloff, Tributary Area (interior) _ Trib - PV Assembly Dead Load W -PV 3 psf / 14 be Net Wintl Uplift aStandoff actual -. NA capacdy of Standoff T -allow 140 lbs Standoff:Demand/Ca acit Interior DCR` 36.5%0 _ Max Allowable Standoff Spacing Portrait Max Allowable Cantilever - Portrait Standoff Configuration Portrait NA Max Standoff Tributary Area (interior) Trib NA PV Assembly Dead Load W -PV NA Net Wind Uplift at Standoff (Interior) T -actual -. NA Uplift Capacity of Standoff T -allow NA Standoff Demand/Ca aeit Interior ccDCR NA