DAVID CHOI & ASSOCIATES
DESIGN CRITERIA
1) All materials and construction shall conform to the requirements of
2019 California Building Code.
2) All lumber shall be Douglas Fir and graded as follows (Grading rule No. 17)
Framing
Grade
Light Framing
Construction
Joist & Planks
No. 2
Beams & Stringers
No. 1
Posts & Timbers
No. 1
3) Glue -Laminated Timbers shall be graded No. 24F -V8.
4) Plywood shall conform to PS 1-09, Structural I.
5) Structural steel shall conform to the following standards:
Wide flange shapes .................................... ASTM A992
HSS shapes .............................................. ASTM A500, Grade B
Pipe shapes .............................................. ASTM A53, Grade B
Other rolled shapes, Bars and plates .............. ASTM A36
6) Structural steel shall be fabricated in an approved fabricator shop.
7) All welding shall be done by certified welders in an approved shop or
in -field with special inspection
8) All concrete shall develop a minimum compressive strength of 2500 psi after 28 days.
9) Reinforcing steel shall conform to ASTM 615, Grade 60.
10) Concrete Block shall conform to ASTM C90, Grade N-1
11) Grout shall develop a minimum compressive strength 2000 psi after 28 days.
12) Mortar shall be Type S and develop a compressive strength of 1800 psi after 28 days.
13) Soil supporting footings shall be natural grade or engineered fill.
14) Soil allowable bearing pressure for design is 1500 psf
15) Footings shall extend a minimum of 181,inches into undisturbed soil or 181, inches
below finished grade, whichever is lower.
\\DCA\Files\ENGINEERING\DCA\Design Aides\DCA-DESIGN CRITERIA
DAVID CHOI & ASSOCIATES
DOUGLAS FIR -LARCH DESIGN VALUES (#, in.)
DESIGNATION
GRADE
FB
FT
Fol
FIC
Fv
E
EmIN
LIGHT FRAMING
CONSTRUCTION
1000
650
625
1650
180
1,500,000
550,000
2'I TO 4" WIDTH
2" TO 4' DEPTH
JOIST & PLANKS
NO.2
900
575
625 '
1350
180
1,600,000
580,000
2" TO 4" WIDTH
6" & DEEPER
POST & TIMBER
NO. 1
1200
825
625
1000
170
1,600,000
580,000
5x5 AND LARGER
DEPTH NOT MORE
THAN 2" GREATER
THAN WIDTH
BEAM & STRINGER
NO.1
1350
675
625
925
170
1,600,000
580,000
5" & WIDER
DEPTH MORE THAN
2" GREATER THAN
THICKNESS
COMBINATION
2400
1100
650
1650
265
1,800,000 930,000
GLU-LAM BEAMS
NO. 24F -V8
Weak -Axis:
1450
1100
560
1650
230
1,600,000 830,000
1) THE ABOVE VALUES ARE TAKEN FROM THE 2018 NDS
2) USE STANDARD GRADING RULE NO. 17.
\\SCOT .HP\USERMPueuo\ENGINEERING\DCA\W-WOOD DESIGN VALUES
ROOF LOADS
Built-up Roofing
11/2" Plywood (On Sleepers)
Sleepers
1/2" Plywood
Rafters (2x10 na. 16" O.C.)
Insulation
Ceiling Joists
1/2" Gyp Board
MP&E/ Misc.
FLOOR LOADS
Flooring
3/4" Plywood
Joist ( 2x12 @ 16" O.C.)
r:aainn - 1/2" GvD Board
DAVID CHOI & ASSOCIATES
DEAD LOADS
2.5 psf
1.5 psf
2.0 psf
1.5 psf
2.5 psf
2.0 psf
2.5 psf
0.5 psf
Lr= 20.0 psf
2.0 psf
2.3 psf
3.5 psf
2.5 psf
(Reducible)
Rafters Design Load
Ceiling Design Load
EXTERIOR WALL LOADS
7/8" Stucco
1/2" Plywood
2x6 Studs @ 16" O.C.
Insulation
1/2" Gyp Board
MP&E/ Misc.
L= 40.0 psf
10.0 psf
1.5 psf
1.5 psf
0.5 psf
2.3 psf
0.2 psf
INTERIOR WALL LOADS
1/2" Gyp Board
2.3 psf
1/2" Plywood
1.5 psf
2x6 Studs @ 16" O.C.
1.5 psf
Insulation
0.5 psf
1/2" Gyp Board
2.3 psf
MP&E/ Misc.
1.9 psf
i Load
\\172.16.0.231\Files\PROJECTS\2021 PROJECTS\21-166 1510 SANDCASTLE DR- VOVAN
RESIDENCE\ENGINEERING\LATERAL\A - Shearwall Design with Macros - 1 Floors v2
"03
a F ®R 0 E MEMBER REPORT PASSED
ROOF, R)1
1 plece(s) 2 x 8 DF No.2 @t 16" OC
10'
All locations are measured from the outside face of left support (or left cantilever end). Al dimensions are horizontal.
Desi nRC51!(t5
.--_. Actual@[dskllp ','
Allowed
Rena.
-
LOF t.oa4e Comb I. Uo"(Pattern
Member Reacdon (lbs)
256 @ 2 1/2"
3281(3.50")
Passed (Si
-- 1.0 D + 1.0 Lr (All Spans)
Shear (Ibs)
214 @ 10 3/4"
1631
Passed (13%)
1.25 1.0 D + 1.0 Lr (All Spans)
Moment (Ft -lbs)
629 @ 5'3 1/2"
1700
Passed (37%)
1.25 1.0 D + 1.0 Lr (All Spans)
Live Load Defl. (in)
0.084 @ 5'3 1/2h
0.339
Passed (L/999+)
-- 1.0 D + 1.0 Lr (All Spans)
Total Load Defl. (In)
0.153 @5,3 1/2"
0.508
Passed (L/795)
-- 1.0 D + 1.0 Lr (All Spans)
• Defiactlonartena: LL(L/anu)ana uLtW—y
• Allowed moment does not reflect the adjustment for the beam stability factor.
• A 15% Increase in the moment capacity has been added to account for repetitive member usage.
• Applicable calculations are based an NDS.
Lateral Brd®Bg Bredng intervals Comments ; "'
fop Edge (1 10' 7" a/c
3ottoio Edi (W) 10'7" /
Maximum allowable bracing Intervals based on applied load.
(,e wring length
"loatls to SuPPotfs (Ibs)
,r:-
BUp.....parlBli .
Total `Available:; Required
,Read
° I: Location (S(de)
1- Stud wall - DF
3.50" 3.50" 1.50"
1167
ME
Blocking
2 -good wall -DF
3.50" 3.50" 1.50"
1167
Blocking
. Blocking Panels are assumed to carry no loads applied directly above them and the full
load is applied to the member being designed.
Lateral Brd®Bg Bredng intervals Comments ; "'
fop Edge (1 10' 7" a/c
3ottoio Edi (W) 10'7" /
Maximum allowable bracing Intervals based on applied load.
0
System: Roof
Member Type: )cost
Building Use : Residential
Building Code : IBC 2018
Design Methodology: ASD
Member Pitch : 0/12
We ernaeuaer-
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not Intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or Ramer Is
responsible to assure that this calculation Is compatible with the overall project Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Weyerhaeuser umbr Pucts have
re been
Installationevaluated
dby Is ICC -ES
er under evaluation reports ESR -1153 and ESR -13137
and/or tested in accordance with applicable ASTM standards. For current ode evaluation reports,product
w+rv+.Weyerhaeuoe mm/woodprodud/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operetta
ForteWEB Software Operator
-
Mike A
Deed
Rauf Live ,
Vera I Load
° I: Location (S(de)
,Spa;m9
(0.90)
.(non -snow 125)
Ca1p111enta
i - Unlfonn(PSF)
LO[o 10'7"
i6"
16.5
2010
1100F+BLEEPERS
0
System: Roof
Member Type: )cost
Building Use : Residential
Building Code : IBC 2018
Design Methodology: ASD
Member Pitch : 0/12
We ernaeuaer-
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not Intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or Ramer Is
responsible to assure that this calculation Is compatible with the overall project Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Weyerhaeuser umbr Pucts have
re been
Installationevaluated
dby Is ICC -ES
er under evaluation reports ESR -1153 and ESR -13137
and/or tested in accordance with applicable ASTM standards. For current ode evaluation reports,product
w+rv+.Weyerhaeuoe mm/woodprodud/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operetta
ForteWEB Software Operator
Sub Nates
Mike A
DCA
(562) 382-8090
magullar@dca-se.com
® 6/10/202110:35:03 PM UTC
A/� ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
RESIDENCE
Weyerhaeuser file Name: 21 -Weyerhaeuser
Page 21 14
WFORTEW MEMBER REPORT PASSED
ROOF, RBI
I piece(s) 4 x 10 DF No.2
I
All locations are measured from the outside face Of left support (or left cantilever end). All dimensions are horizontal.
Design Results I � � I
I Actual 0 L0010013
�Allovmd �
i��
—(26-/.)
LIDIF , LoadCoolublPilthIffi(tibull)'
Member Reaction (lbs)
1988 @ 2"
7656 (3.50")
Passed
1.0 D + 1.0 Lr (All Spans)
Shear (lbs)
1466 @ V 3/4!'
4856
D to 8- V
1.25 1.0 D + 1.0 Lr (AJI Spans)
Moment (Ft -lbs)
3693 0 4' 1127
5615
passed (66%)
1.25 1.0 D + im Lr (All Spans)
Live Load Dell. (in)
0.051 @ — 4' 112'
0.258
Passed (L/999+)
— 1.0 D + 1.0 Lr (All Spans)
Total Load Defl. (in)
0.108 @ IV 1/21,
0.387
Passed (L/860)
1.0 D + 1.0 Lr (All Spans)
I DelleolOnUnna n LLLW50UJd11U 06%W—P
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable otmiations; are based an NDS.
Bearing Length icadi to SOPlains(Ibs)
Total n, 11 A0Ce550rIW,
T
Supports _Al�rafjabheq�� .Dead
1 -Column -DF 3.50 3.50" LW 1I59 930 1989 aloccing
—5W Bloclin,
2 -Column -DF above
15 1! S! 'a"
. BlocWng Panels are assumed to carry no loads applied directly ov dik a� tWhe full Ima TL &PPIlid to rnalWr being designed.
Lateral Bracing
a Into !vda . . , '
s
I lop Edge (LU)
V A o/c
Bottom Edge (LU)W
1.
.maximum allowabletrading Interwah, based on applied lead.
auseimotw:::�
warrants that the sizing of Its products will be In accordance with Weverhaeu
oftwwe. Use of this software is not Intended to circumvent the need for a de
More that this calculation is compatible with the overall project AccessmaS
facilities are third -party certified to sustainable forestry standards. Weyerhae
n accordance with applicable ASTM standards. For current code evaluation rs
!uwr.mmtwoodproducts/d=mnt-llbmry.
)plication, Input design loads, dimensions and support information have been
sagn criteria and published dol
coal as determined by the author
Blocking Panels and Squash Bloc
red Lumber Products have been
hasuser product literature and it
RrteWEB Software operator
FortewEll Software Operator
--7-7-777-7777777
MikeA
FuNaff Live
Vertical Loads
Location (side)(side)Tributary
Width
(non -arrow
0 - Self Weight (PLF)
D to 8- V
NIA
8.2
—
7- —Uniform (PSF)
0 to 81 1- (Top)
W,
16.5
20.0
ROOF + SLEEPERS
2 - Uniform (PSF)
0 to a, I- (TOP)
4'
16.0
-
EXT. WALL
3 - Uniform (PSF)
D to 8' 1" (Top)
5.6"
15.5
20.0
(E) ROOF
auseimotw:::�
warrants that the sizing of Its products will be In accordance with Weverhaeu
oftwwe. Use of this software is not Intended to circumvent the need for a de
More that this calculation is compatible with the overall project AccessmaS
facilities are third -party certified to sustainable forestry standards. Weyerhae
n accordance with applicable ASTM standards. For current code evaluation rs
!uwr.mmtwoodproducts/d=mnt-llbmry.
)plication, Input design loads, dimensions and support information have been
sagn criteria and published dol
coal as determined by the author
Blocking Panels and Squash Bloc
red Lumber Products have been
hasuser product literature and it
RrteWEB Software operator
FortewEll Software Operator
Job Not"
MikeA
DCA
(562) 382-8040
Maguilar@dm-se.com
System i Roof
:DropMember Type Beam
Building Use: Residential
Building Code: IBC 2018
Design Methodology: ASD
Member Pitch : 0112
iiaeuser cocipmely disclaim any other warranties
cHon. The designer of record, builder or framer is
red by this software. Products manufactured at
ES under evaluation reports ESR -1153 and ESR -1387
refer to
6/101202110:35:03 PM UTC
AForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 File Name: 21-166 VOVAN RESIDENCE
Weyerhaeuser Page 3 / 14
'EM
91 F O R T E MEMBER REPORT PASSED
ROOF, RB2
1 p)ece(s) 4 x 6 DF No.2
0
5'
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
:DeS)JO ResiJlts
pptimi@Location
,:Allowed �'
Result -
LOF ination(Pattern)
Member Reaction (lbs)
487 @ 2"
7656 (3.50")
Passed (6%)
— Lr (All Spans)
Shear (Ibs)
453 @ 9"
2688
Passed (16%)
1.25 Lr (All Spans)
=1.
Moment (Ft -lbs)
1119 @ 2' 10"
2151
Passed (52%)
1.25 Lr (AII Spans)Uve
Load Deft. (In)
0.026 @ 2' 10 7/8"
0.183
Passed (L/999+)
-- Lr (AII Spans)Total
Load Deft. (in)
0.065 @ 2' 10 15/16"
0275
Passed (L/999+)
-- 0 Lr (AII Spans)
Defleaon Cmena:LLtVCUe)anu[�u.,�P
Allowed moment does not reflect the adjustment for the beam stability factor.
Appllcable calculations are based on NDS.
Bearing Length Lapdste Supports Obs)
Supports
Total - ^Avsliabk Required eead RooF live 'Total, Accessotles
1 -Column -DF 3.SP' 3.50" 1.50" 313 174 487 Blocking
2 -Column -DF 3.50" 3.50" 1.50" 303 163 466 BNW—
• Blocking Panels are assumed to curry no loads applied dlrety above mem and me full load Is applietl to the member being designed
Wteral Brading
Brening Ii)tersals Commants
Top Edge (Lu)
5' 10" o/c
Bottum Edge (W)
5' 10" o/c
.Maximum allowable bracing intervals based on applied load.
0
System: Roof
Member Type : Drop Bem
Building Use : Residential
Bullding Code: IBC 2018
Design Methodology: ASD
Member Pitch :0/12
We erhaeuser Notes
Weyerhaeuser warrants that the sizing of Its products will be In accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disdaims any other warranties
related m the software. Use of ibis software is not intended to ciramvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible m assure that this calculation is compatible with the overall project Accessories (Rim Board, Blocking Panels and Squash Prods) are not designed by this softmene. Products manufactured at
Weyerhaeuser facilities are third -party cerdfled to sustainable forestry standards. Weyerhaeuser Engineered umberProducts
uteratu v and Installation valuated
detalls refer rider evaluation reports ESR -1153 and ESR -1307
and/or tested in accordance with applicable ASTM standards. for current code evaluatlonreport,, y product
w ,weyerhaeuser.mm/woodproducts/document-libmry.
The product appikadon, Input design loads, dimensions and support information have been provided by ForteWEB Software Operator
For, WEB Software operator
Job Notes
MIkeA
Dead
^Roof Live
(562)382-8040
maguilar@dca-se.com
Vertical Loads,
-� Lontion (slae>
Td6ubry Width
(0.90)
(non -snow. L.25)
Comments
0- Selff Weight(PLF)
0to5'10"
N/A
4.9
—
1 -Uniform (PSF)
0 to 5' 10" (Top)
4'
10.0
-
CRIPPLE WALL
2 - Point Olt)
2' 10" (Top)
N/A
354
337
Unked from: E81,
Support 1
0
System: Roof
Member Type : Drop Bem
Building Use : Residential
Bullding Code: IBC 2018
Design Methodology: ASD
Member Pitch :0/12
We erhaeuser Notes
Weyerhaeuser warrants that the sizing of Its products will be In accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disdaims any other warranties
related m the software. Use of ibis software is not intended to ciramvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible m assure that this calculation is compatible with the overall project Accessories (Rim Board, Blocking Panels and Squash Prods) are not designed by this softmene. Products manufactured at
Weyerhaeuser facilities are third -party cerdfled to sustainable forestry standards. Weyerhaeuser Engineered umberProducts
uteratu v and Installation valuated
detalls refer rider evaluation reports ESR -1153 and ESR -1307
and/or tested in accordance with applicable ASTM standards. for current code evaluatlonreport,, y product
w ,weyerhaeuser.mm/woodproducts/document-libmry.
The product appikadon, Input design loads, dimensions and support information have been provided by ForteWEB Software Operator
For, WEB Software operator
Job Notes
MIkeA
DCA
(562)382-8040
maguilar@dca-se.com
6110/20211035:03 PM UTC
ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16
File Name: 21-166 VOVAN RESIDENCE
Weyarnaeaspr
Page 5 / 14
'EM
I F®RIG MEMBER REPORT PASSED
ROOF, R53
1 piece(s) 4 x 8 DF No.2
M
All locations are measured from the outside face of left support (or left cantilever end). Al dimensions are horizontal.
40603
9 1/2" 1 3737
Total Load Defl (in) I 0.035 @ 3' 9112" 1 u-»-
• Dell Tm criteria: LL (L/360) and TL (L/240).
• Allowed moment does at reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
D + 1.0 Lr
D + 1.0 Lr
D-+ 1.0 Lr
1.0 D
aupParr u, -...
3.50" Hangers 1.50" 210 228 438 Bee nate a
1- Hanger on 71/4' DF beam ___
2 H g 71/4 DF scam3 50 H g 150" 210
ISea note
. At hanger supports, the Total eeanng tlimension I5 equal b the ItlM of the t al th t pport g th h ge
.. See Connector grid below for additional information and/or requirements.
0
System : Roof
Member Type: Drop Beam
Building Use : Residential
Building Code: IBC 2018
Design Methodology: ASD
Member Pitch: 0/12
ForteWEB Software Operator
Mike A
Sob Notes
DCA
(562) 382-8040
Weyerhaeuser
maguilar@dca-se.com
6/10/2021 10:35:03 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
File Name: 21-166 VOVAN RESIDENCE
Page 6 / 14
MEMBER REPORT
ROOF, 1184
1 piece(S) 4 x 8 DF N0.2
Sloped Length 6' 11 1/4"
_ _ m<a ... m from the outside face of left support (or left cantilever end). All dimensions are horizontal.
• Allowed moment does not reflect the adjustment far the beam scapmry maul-
, Applicable calculations are based on NDS.
Plate - OF
Plate - OF
Top Edge (W)
Bottom Edge (W)
•Mmdmum a1kimble badng
2 - Point (Ib)
3 - Point (Ib)
3.50" 3.50"
3.50" 3.50" 1.50"
6' 11" 0/c
6' Iv o/c
based on appiled lead.
292 1 297L 589
2T7 --r-291 T578
0 to 6' 7"
N/A
01 6' 7"
1'
16.5
20.0 ROOF
linked from: RB3,
1•
MIA
210
228 Support 1
linked from: R83,
TV
N/A
210
220 Support 1
PASSED
Member Length : 7' 111/16"
System : Roof
Member Type: Flush Beam
Building Use: Residential
Bantling Code: IBC 2018
Design Methodology : ASD
Member Pitch: 4/12
:user Notes
�, j g builder or framer is
warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disdaims any other warranties
software. Use of this software is not intended to circumvent the need for a design professional as determined by the authod havingjurisdiction. The desi nee of record,
assure chat this calculation is rompatihle with the overall project Accessories (Rim Board, Blacking Panels and Squasawah Blocks) are not designed W this software. Products manufactured a[
in accordance ucts h, been evaluated by ICC
facilities rethini- app, certfied to standards,inablffor�ent code evaluation erh reports, Wieyerh�aeusenr produber ct literature, llteraNre and lnstallationetai s refer W evaluation reports FSR -1153 antl ESR -1387
eusercom/woodpmducN/dommentAibmry.
i—,n dimensions and support Information have been provided by ForteWEO Software Operator
FarteWEB Software Operztor Sob Notes
Mike A
DCA
(562)382-8040 Weyerhaeuser
maguilarVea-se.com
6/10/202110:35:03 PM UTC
ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16
File Name: 21-166 VOVAN RESIDENCE
Page 7 / 14
MEMBER REPORT
ROOF, RBS
1 piece(s) 4 x 10 DF No.2
all Inratlnns are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
AGualQ Location
-Allowed -Basalt
'.<
LDF Load: DombInsiders, (Pattern)
Member Reaction (Ibs)
1175 @ 2"
7656 (3.50")
Passed (15%)
-- 1.0 D + 1.0 Lr (All Spans)
Shear (lbs)
936 @ 1' 1/4"
4856
Passed (19%)
1.25 1.0 D + 1.0 Lr (All Spans)
Moment (Ft -lbs)
2769 @ 5' 1/2"
5615
Passed (49%)
1.25 1.0 D + 1.0 Lr (All Spans)
Live Load Dell. (in)
0.073 @ 5' 1/2"
0.343
Passed (L/999+)
-- 1.0 D + 1.0 Lr (All Spans)
Total Load Defl. (in)
0.143 @ 5' 1/2"
0.514
Passed (1-1865)
-- 1.0 D + 1,0 Lr (All Spans)
• Deflection otters: UL (Lfabul ano r c ty[+ut.
• Allowed moment does not reflex the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
- Bearin9l¢ri9th Loads; is Supporta (lbs)
=in
`- Required eeof Livepports 1 -Beveled Plate- DF 1.50"570 605 il]5 Blocking
2- Beveled Plate -DF 1.50"570 605 1175 Blocking
Blocking Panels are assumed to carry no loatlsem antl the wll load is applied to the member being designed.
Lateral BreClllg
.emdn9Intervab - Comments
ToP Etlge (Lu)
f0' 8" o/c
Bottom Edge (1
10' 8" o/c
.rn•dmum allowable bmcinn intervals based on applied load
PASSED
G)
Member Length : 10'10 5/8"
System :Roof
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology: ASD
Member Pitch :4/12
We erhaeuser Notes
Weyerhaeuser warrants that the sizing of Its products will be in accordance with Weyerhaeuser product design cetera and published design values. Weyerhaeuser eon. The Vressfy of remind,
any other r frame is
related to Ne software. Use of this software is not intended to circumvent the need for a d Resign professi Pla ne Panels and Squashby the uBlocks) arethority lnat designg ned by lingoftware.tproduct; mlanufactured at s
responsible to assure that this calculation Is compatible with the overall project Accessories Rim Board, 9
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products
literature and installations tleta have been valuated by CCrefer Coder evaluation Trillions, ESR -1153 and ESR -1387
and/cur tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product
www.weyerhaeuRr.com/modproduU /domment-library.
The product application, Input design loads, dimensions and support inormation have been provided by ForteWEB Software Operator
ForteWES Software Operator
Boar
Roof LWe
Vertical Leads
- Locstlon (Wis) Trlbrrmry Width (0.90)
(non-snow:1.75)
Commems ,
0-Sel(Weight(PLF)
Om10'1" N/A
1 -Uniform pso
Oto 30'1" 6' 16.5
20.0
RODF
PASSED
G)
Member Length : 10'10 5/8"
System :Roof
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology: ASD
Member Pitch :4/12
We erhaeuser Notes
Weyerhaeuser warrants that the sizing of Its products will be in accordance with Weyerhaeuser product design cetera and published design values. Weyerhaeuser eon. The Vressfy of remind,
any other r frame is
related to Ne software. Use of this software is not intended to circumvent the need for a d Resign professi Pla ne Panels and Squashby the uBlocks) arethority lnat designg ned by lingoftware.tproduct; mlanufactured at s
responsible to assure that this calculation Is compatible with the overall project Accessories Rim Board, 9
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products
literature and installations tleta have been valuated by CCrefer Coder evaluation Trillions, ESR -1153 and ESR -1387
and/cur tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product
www.weyerhaeuRr.com/modproduU /domment-library.
The product application, Input design loads, dimensions and support inormation have been provided by ForteWEB Software Operator
ForteWES Software Operator
Job Notes
MIkeA
DCA
(562)382-8040
magullar@dra-se.com
6/10/202110:35:03 PM UTC
ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16
File Name: 21-166 VOVAN RESIDENCE
Wcyerhaeusv
Page 8 / 14
� WEB
I
MEMBER REPORT
ROOF, RB6
1 pieces) 3 1/2" x 18" 2.2E Parallam@ PSL
to
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal
neciciiiRe5l1it5
Au Mal 0 Lobattpn
�Allowed�
- Result
LOF ' Coad: Combinai
Member Reaction (lies)
5381 @ 2'
7656 (3.50")
Passed (70%)
— 1.0 D + 1.0 Lr
Shear (Ibs)
4929 @ 1' 91/2"
15225
Passed (32%)
1.25 1.0 D + 1.0 Lr
Moment (Ft -lbs)
31191 @ 7' 2"
54581
Passed (57%)
1.25 1.0 D + 1.0 Lr
live Load Dei. (in)
0.326 @ IV S 3/4"
0.725
Passed (U801)
- 1.0 D + 1.0 Lr
Total Load Dei. (in)
0.704 @ 10' 6 5/8"
1.067
Passed (L/371)
-- 1.0 D + 1.0 Lr
• Deflection criteria: LL (L/360) and TL (1/240).
• Allowed moment does not reflect the adjustment for the beam stability factor
i - Column - DF 3.50" 3.50" 2.46" 2894 .2486 5380 None
_ 3.5 0" 3.50" 1.84" 2256 1760 9016 None
2 -Column -DF
0 -Self Weight (PI.F) Ota 22'11 coir• •"'
1- Uniform (PSF) 0 to 22' 1" (Top)
2 - Uniform (PSF) 0 to 22' 1" (Tap)
3 -Paint (Ib) 7' 2"(TOP) N/A 1790
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be In accordance wird Weyerhaeuser pr
related N the software. Use of this software Is not intended N circumvent the need for a design P
responsible to assure that this
Rim
.," "
wmaswbNoose
ds aethird-partymulletouvIzl forestry standards Weyerhaeuser
Weyerh.efl"r,rordanc¢
with aoolkable ASTM standards. For current code evaluation reports,
20.0 (E) ROOF
EI(r. WALL
2038 Linked from: EB2,
Support 1
on cdteda and Published design
I as determined by the authority
dying Panels and squash Blacks)
Lumber Products have been eva
.neer product literature and Instal
FortewES Software operator
Mike A
Sob Notes
DCA
(562)382-8040
Weyerhaeuser
magular@dca-se.com
0
PASSED
System : Roof
Member Type: Drop Beam
Building Use: Residential
Building Code: IBL 2018
Design Methodology: ASD
Member Pitch : 0/12
lues. Weyerhaeuser expressly disclaims any other warranties
wing jurisdiction. The designer of record, builder or framer is
'e not designed by this software. Products manufactured at
died by ICC -ES under evaluation reports ESR -1153 and FSR -1387
tion details refer to
6/10/202110:35:03 PM UTC
ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16
File Name: 21-166 VOVAN RESIDENCE
Page 10 / 14
s4FORTECM MEMBER REPORT PASSED
ROOF, RB7
1 piece(s) 4 x 10 OF No.2
4' 6"
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Result ,
', "al @Loodtkm
Allowed
-:RPS it
LBF Load icombination(Pattern)
Member Reaction (lbs)
612 @ T'
7656 (3.50")
Passed (8%)
-- 1.0 D + 1.0 Lr (All Spans)
Shear (lbs)
356 @ 1'3/4"
4856
Passed (7%)
1.25 1.0 D + 1.0 Lr (All Spans)
Moment (Ft -lbs)
679 @ 2'6 11Z'
5615
Passed (12%)
1.25 1.0 D + 1.0 Lr (All Spans)
Uve Load Dell. (in)
0.003 @ X 6 1/2"
0.158
Passed (L/999+)
-- 1.0 D + 1.0 Lr (All Spans)
Total Load Dell. (in)
0.007 @ 2' 6 1/2"
0.237
Passed (L/999+)
-- 1.D D + 1.0 Lr (All Spans)
• Deflection criteria: LL (U360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Supports -
Beadn9 Length.
Total Avalleble� Requiretl
Loadc tp Sepports Obs), ..
'oeatl Aoof Live Total
Accessories
1 -Column -DF
3.50" 3.50" 1 1.50" 1
358 254 1 fits
1 None
2 -Column -DF
3.50" 3.50" 1 1.50" 1
35B 259 1 612
1 None
Lateral Bracing
Brednginter"bi icornal is.�:, _
Top Edge (W)
5' I" o/c
Bottom Edge (W)
5' 1" o/c
-Maximum allowable bracing Intervals based on applied load.
vertical Lo8f1S'
U ovation (Side)
Tributary Width
Dead ' -Root Live ,
(npn-sngw:1.2§) comments
0- Self Weight(PLF)
Oto sl ill
N/A
8.2 —
I - Uniform (PSF)
0 to 5' 3" (Top)
TI6.5
20.0 (E) ROOF
2 - Uniform (PSF)
0 W 5' 1" (Top)
5'
10.0 . EM. WALL
System: Roof
Member Type: Drop Beam
Bullding Use : Residential
Bullding Code : IBC 2018
Design Methodology: ASD
Member Pitch: 0112
warrants that the sWng of Its products will be In accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disdaims any other warrants
oftware. Use of this software Is not Intended to arcumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
assure that this alculadon is compatible with the overall project. Accessorles (Rim Board, Blacking Panels and Squash Blocks) are not designed by this software, Products manufactured at
facllities are NIM -party certified to sustainable forestry, standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC -ES under evaluation reports ESR -1153 and ESR -1387
i accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
dimensions and support Information have been
ForteWEB Software Operator
Job Notes
MIkeA
DCA
(562)382-8040
maguilar@da-se.com
6/10/2021 10:35:03 PM UTC
ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: 21-166 VOVAN RESIDENCE
Page 11 / 14
2.83F
MEMBER REPORT
ROOF, EBS
1 piece(s) 4 x 10 DF No.2
Sloped Length: 14' 9 15/15"
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
'Allowed
ResdtLoaf:
Combination (Pattern)
Member Reaction (lbs)
1298 @ 14' 111/16"
3281(1.50")
Passed (40%)
-- 1.0 D + 1.0 Lr (All Spans)
Shear (Ibs)
1098 @ 13' 411/16"
4856
Passed (23%)
1.25 1.0 D + 1.0 Lr (All Spans)
Moment (Ft -lbs)
3549 @ 8' 17/8"
5615
Passed (63%)
1.25 1.0 D + 1.0 Lr (All Spans)
Live Load Dail. (in)
0.176 @ 7' S"
0.479
Passed (U980)
-- 1.0 D + 1.0 Lr (AII Spans)
Total Load Defl. (in)
0.349 @ 74 13/16'
0.718
Passed (U493)
-- 1.0 D + 1.0 Lr (Al Spans)
• Deflection criberix LL (U360) and R
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
`: Bearing Lengtlt `L Loads to supports (Iba)
$UpPOrt4 '
Total Available'. 'Raquirea ';oeaaRoof Ligetotal pccessorias
1 -Beveled Plate - SPF 3.50" 3.50" 1.50" 354 337 691 Blaking
2 - Hanger an 9 1/4" SPF beam 3.50" H!.'50'"" 1.50" 635 663 1298 See nate'
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is appimis to the member being designed,
nger supports, the Total Bearing dimension is equal to the width or the material tnat is supporting me mange,
Connector grid below for additional information and/or requirements.
Lateral B1'acing . 'etapng'irrtervels Comments '
ToP Edge
Bottom Etlge (Lu) 14' 6" o/c
•maximum allowable bracing Intervals based on applied load.
PASSED
Member Length : 14' 8 9116 -
System :
/16"
System: Roof
Member Type: Flush Beam
Bulltling Use: Residential
Building Code : IBC 2018
Design Methodology: ASD
Member Pitch : 2.83/12
Connector: Simpson Strong- le
Srjppgrt '-. Modd Seat Length Top Fasteners - "+' Face Fasteners Member Fasteners JAmeaswifee,
2 -Face Mount Hanger LSSR4102 1.88" N/A 22-16dx2.5 18-16dx2.5
• Refer to manufacturer motes and IRQru[rkms ist proper Installation and we of all connectors.
We erhaeu`serNotes
Weyerhaeuser warrants that the siring of its products will be In accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclalaa any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction, The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blaldng Panels and Squash Blocks) are not designed by this software. Pmtluds manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standard$. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC -ES under evaluation reports ESR -1153 and ESR,1387
and/or tested in accordance with applicable ASTM smndai For current code evaluation reports, Weyerhaeuser product literature and Installation details refer to
www.weyerhaeuser.mm/woodpmducrs/domme t-libmry.
The product application, Input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Fortewela S,ftwara operator
]ab Notes
Dead -Roof Live
ForteWEB 0.2, Engine: V8.2.0.17, Data: VS. 1.0.16
VertiCa) Loads , -- Location (side)
Tdbuiary Width
(o.9D) (non -snow 1.25)
Comments
0 -Self Weight(PLF) 0 to 14' 111/16"
N/A
8.2
I -Tapered (PLF) 0 to 14' 111/16"
N/A
0.0 to 119.7 0.0 to 141.4
Generated from
Roof Geometry
We erhaeu`serNotes
Weyerhaeuser warrants that the siring of its products will be In accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclalaa any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction, The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blaldng Panels and Squash Blocks) are not designed by this software. Pmtluds manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standard$. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC -ES under evaluation reports ESR -1153 and ESR,1387
and/or tested in accordance with applicable ASTM smndai For current code evaluation reports, Weyerhaeuser product literature and Installation details refer to
www.weyerhaeuser.mm/woodpmducrs/domme t-libmry.
The product application, Input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Fortewela S,ftwara operator
]ab Notes
MIkeA
ForteWEB 0.2, Engine: V8.2.0.17, Data: VS. 1.0.16
DCA
File Name: 21-166 VOVAN RESIDENCE
(562)382-8040
Page 4 / 14
magullar@dw-se.com
6/10/202110:35:03 PM UTC
ForteWEB 0.2, Engine: V8.2.0.17, Data: VS. 1.0.16
Wryarluav:u
File Name: 21-166 VOVAN RESIDENCE
Page 4 / 14
a 9' ®1 [ 1 E MEMBER REPORT PASSED
ROOF, EB2
1 piece(s) 6 x 12 DF N0.1
Overall Length: 13'7"
)3'
All Incations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actuai @ Location -
-'`Allowed
Resuk
LDF '. Loed: Combina9dn (Pattern)
Member Reaction (lbs)
3827 @ 2"
12031(3.50")
Passed (32%)
-• 1.0 D + 1.0 Lr (All Spans)
Shear (lbs)
3123 @ VY
8960
Passed (35%)
1.25 1.0 D + 1.0 Lr (All Spans)
Moment (Ft -lbs)
12367 @ 6'9 1/2"
17048
Passed (73e1.)
1.25 1.0 D + 1.0 Lr (All Spans)
Live Load Defl. (In)
0.187 @ 6' 91/2"
0.442
Passed (L/852)
- 1.0 D + 1.0 Lr (All Spans)
Total Load DeN. (in)
0.350 @ 6' 9 1/2"
0.663
Passed (L/454)
-- 1.0 D + 1.0 Lr (All Spans)
• Deflection arteria: LL (Ly]au) aria IL
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Lumber grading provisions must be extended over the length of the member per NDS 4.2.5.5.
• Appllcable calculations are based an NDS.
ela
Lateral BraFing Battle Igbery
- ��- Comments l
Top Edge (Lu) ITT' o/c
Bottom Edge (Lu) IT 7" a/c
.maximum allowable bracing intervals based on applied load.
- peatl Iledf Llva
:rtiCel LOdds Location (Sitle) Trihutary Width (0.90) ' (no wow. 3.25) Coinmards
Self Weight (PLF) 0 to 13' 7" N/A 16.0 --
Uniform (PSF) 0 to 13' 7" (Top) _ 15' 16.5 20.0 (E) ROOF
System : Roof
Member Type: Flush Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology: ASD
Member Pitch : 0/12
WeVerhailuser Notes
Weyerhaeuser warrants that the sizing of Itr pratluctr will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other wanandes
related to the software. Use of this software is not Intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of raok, builder or framer Is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -parry certified 0 sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC -ES under evaluation reports ESR -1153 and ESR -1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuseccom/woo imoducts/document-library.
The product application, Input design loads, dlmenslons and support Information have been provided by ForteWEB Software Operator
PorteWES Software Operator
Sob Notes
-; Bearing Length
'Itl.aatlsm Supports (lbs)
supports,
Total, Available' Required,
ead Roo(.Live Total Auxssories
-
1 -Stud wall -DF
3.50" 3.50" 1.50"
1790 2038 3828 Bkrcking
2-Studwall-DF
3.50" 3.50" 1.50"
1790 2038 3828 Blocking
• Blocking panels are assumed to carry no loads applied directly above Mem and the Fu I
load is applied to the member being designed.
ela
Lateral BraFing Battle Igbery
- ��- Comments l
Top Edge (Lu) ITT' o/c
Bottom Edge (Lu) IT 7" a/c
.maximum allowable bracing intervals based on applied load.
- peatl Iledf Llva
:rtiCel LOdds Location (Sitle) Trihutary Width (0.90) ' (no wow. 3.25) Coinmards
Self Weight (PLF) 0 to 13' 7" N/A 16.0 --
Uniform (PSF) 0 to 13' 7" (Top) _ 15' 16.5 20.0 (E) ROOF
System : Roof
Member Type: Flush Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology: ASD
Member Pitch : 0/12
WeVerhailuser Notes
Weyerhaeuser warrants that the sizing of Itr pratluctr will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other wanandes
related to the software. Use of this software is not Intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of raok, builder or framer Is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -parry certified 0 sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC -ES under evaluation reports ESR -1153 and ESR -1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuseccom/woo imoducts/document-library.
The product application, Input design loads, dlmenslons and support Information have been provided by ForteWEB Software Operator
PorteWES Software Operator
Sob Notes
Mike A
DCA
(562)382-8040
magullar@dm-se.com
6/10/202110:35:03 PM UTC
ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: 21-166 VOVAN RESIDENCE
Page 9 / 14
'CM
I FO R S E MEMBER REPORT PASSED
ROOF, H1
1 plece(S) 4 x 6 DF No.2
0
6
All locations are measured from the outside face of left support (or left cantilever end). Al dimensions are horizontal.
De91 DRe511iL5
Act0a18lnmtlan
-: Allo Wed r
Result I ILDF
Loads Combinathan (Pat6wn)
Member Reaction (Ibs)
1014 @ 0
3281(1.50")
Passed (31%)
-- 1.0 D + 1.0 Lr (All Spans)
Shear (Ibs)
824 @ 7"
2888
Passed (290/6)
1.25 1.0 D + 1.0 Lr (All Spans)
Moment (Ft-Ibs)
1584 @ 3' 11/2"
2151
Passed (74%)
1.25 1.0 D + 1.0 Lr (All Spans)
Live Load Defl. (in)
0.062 @ 3111/211
0.156
Passed (L/999+)
-- 1.0 D + 1.0 Sr (All Spans)
Total Load DeO. (in)
0.143 @ 3,11/2"
0.313
Passed (L/523)
— 1.0 D + 1.0 Lr (All Spans)
• Deflection rater: u- ti^,) ane uL
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
'( Bearing Lan9th `. toads to 5uppo'r1s (Ibs)
$YpPorts Total Available:; Requlred --Dead Roof_Wa 'notal A
1 -Trimmer -DF1.50" 1.50" LSV 576 438 1014 None
2 •Trtmmer-DF 1.50" 1.50" 1.50" 576 438 1014 None
LBberal Bracing Bradng,Intervals Comments
Tap Edge (Lu) 6'3' o/c
Bottom Edge (Lu) 6' 3" o/c
•Madmum allowable bracing Intervals based on applied load.
Vertical.Load9
Wee on -'� Tdbutary WldN
-Deed Rout (clue.
(0.90) (non -snow 1.25)
Comments -
0 - Self Weight (PUFF)
0 to 6' 3" N/A
4.9—
1- Uniform (PSF)
0 to V 3". 7'
16.5 20.0
ROOF
2 - Uniform (PSF)
0 to 6'3" 4'
16.0 -
TF WALL
0
System: Wall
Member Type: Meader
Building Use : Resldential
Building Code! IBC 2016
Design Methodology: ASD
We rhaeuser.Notes
Weyerhaeuser warrants that the slang of its products will be In accordance with Weyerhaeuser product design cntena and published design values. Weyerhaeuser expressly disclaims any other
or wawa bels
related to the software. Use of this software is not Intended to circumvent the need for a design professional as determined b the author havingudsdiction. The designer of record, builder
responsible to assure that this calculation Is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blacks) are not designed by this software. Products manufactured at
Weyerhaeuser falliNes are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by IGC -ES under evaluadon reports FSR -1153 and ESR -1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reparls, Weyerhaeuser product literature and installation details refer to
www.vreyerhaeuser.mm/wmdproduca/documenMibmry.
The product apPllaBon, input design loads, dimensions and support Information have been provided by FarteWEB Software Operator
ForteWER Software Operator
3ob Notes
Mike A
DCA
(562)3B2-8040
maguilarOdca-se.com
6/10/202110:35:03 PM UTC
FOrteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16
File Name: 21-166 VOVAN RESIDENCE
Weyerhaeuser Page 12 / 14
�1FORTEZM MEMBER REPORT PASSED
ROOF, H2
1 pieces) 4 x 6 OF No.2
All locations are measured from the outside face of left support (or left canillever end). All dimensions are horizontal.
Design Restl)1s
Actual® Location
- Allowed
; -Result
.LDF Load: Combldatlon (Pattein)
Member Reaction (lbs)
137800
3281(1.50")
Passed (42%)
-- 1.0 D + 1.0 Lr (All Spans)
Shear (Ibs)
1072 @ 7"
2688
Passed (37%)
1.25 1.0 D + 1.0 Lr (All Spans)
Moment (Ft -lbs)
1809 @ 2'7 1/2!'
2151
Passed (84%)
1.25 1.0 D + 1.0 Lr (All Spans)
Live Load Dail. (in)
0.055 @ 2'7 1/2"
0.131
Passed (U999+)
-- 1.0 D + 1.0 Lr (All Spans)
Total Load Dell. (in)
0.116 @ 2'7 1/2"
0.262
1 Passed (U545)
-- 1.0 D + LG Lr (All Spans)
• Deflection criteria: LL (U480) and TL (4240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable olculatians are based an NDS.
Supports
-
.7;1'
Bearin9Loadato
Available, Requrretl
suppurts(Iba)- '
'Deatl ' Roof pve To[al .
Ae<eswries '
1 -Trimmer -DF
1.50"
1.50" 1.50"
722 656 1378
None
2 -Trimmer -DF
1.50"
1.50" 1.50"
722 656 1378
None
L2teF2( Bp3dIDJ , BONng Ieterwis i'
Comments,
Top Edge (Lu) FY a/c
.110) (9.90)
Bodam Edge (Lu) S'3' a/c
0 - Self Weight (PLF)
-Maximum allowable bracing intervals based on applied load.
[.Loads
Location -' --
Tdbutary VA
.110) (9.90)
(nonar ow 1.75), Com comb
0 - Self Weight (PLF)
0 to 5' 3"
N/A
4.9
—
1- Uniform (PSF)
0 to 5'3"
12-6"
16.5
20.0 ROOF
2 - Uniform (PSF)
0 to 5'3"
4'
16.0
- EXT. WALL
Weyerhaeuser warrants that the sizing of Its products will be in accordance with Weyerhaeuser pr
related to the software. Use of this software is not intended to circumvent the need for a design p
responsible to assure that this osculation Is compatible with the overall pro)ecL Aaeuories (mm
Weyerhaeuser facilithes are third -party certified to sustainable forestry standards. Weyerhaeuser E
and/or tested in accordance with applicable ASTM standards. For current code evaluation report,
dimensions and support information have been provided by
Fo"'WEB softwareOperator
]ob Notes
Mike A
DCA
(562)382-8040
magullar@do-se.com
System: Wall
Member Type: Meader
Bullding Use : Recderbal
Building Cade : IBC 2018
Design Methodology: ASD
Reda and published design values. Weyerhaeuser expressly disclaims any other warranties
letermined by the authority having Jurisdiction. The designer of record, builder or framer Is
Panels and Squash Blocks) are not designed W this software. Products manufactured at
aer Products have been evaluated by ICC -ES under evasuaflon reports ESR -1153 and ESR -1387
product literature and Installation details refer to
6/10/2021 10:35:03 PM UTC
ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: 21-166 VOVAN RESIDENCE
Page 13 / 14
!9I F ®R 1 E MEMBER REPORT PASSED
ROOF, H3
1 plece(s) 4 x 10 DF No.2
II
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @Location
'•IUlowed
ResuR
GDF Load: Co mbinaiion(Pattern)
Member Reaction (lbs)
1859 @ 0
3281(1.50")
Passed (57%)
-- 1.0 D + 1.0 Lr (All Spans)
Shear (lbs)
1550 @ SO 3/4"
4856
Passed (32%)
1.25 1.0 D + 1.0 Lr (All Spans)
Moment (Ft -lbs)
4997 @ 5' 4 1/2"
5615
Passed (89%)
1.25 1,0 D + 1.0 Lr (All Spans)
Live Load Defl. (in)
0.122 @ 5'4 1/2"
0.269
Passed (L/999+)
-- 1.0 D + 1.0 Lr (All Spans)
Total Load Defl. (in)
0.281 @ 5'4 1/2"
0.538
Passed (1/458)
-- 1.0 D + 1.0 Lr (All Spans)
• Deflection Miens: u (t/9au) ano i c kW"J.
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Bearing length Loads to supporbc 0ba4
iuppOlts Total "ilable_- Required . Dcad Ro.ftive Total Attessurlea
-Trimmer - OF 1.50" 1.50" 1.50" 1053 806 1859 None
Trimmer - OF 1.50" 1.50" 1.50" 1053806 1859 None
2ter818raCIDJ Bracinglptervais ', Gbmmenb
by Edge (Lu) _ 10' 9" o/c
WttDm Edge (Lu) 10' 9" o1c
Maximum allowable badull Intervals based on applied load.
Vertical Loads
.Location.
Tdbrr�ry Wldtlr
Dead
(O.gO) :
Rao/Live
(noesriow: 3.25) Oomineids
0 - Self Weight (P1F)
0 to 30' 9"
N/A
8.2
—
1- Uniform (PSF)
0 to 10' V
7-6-
16.5
20.0 ROOF
2 - Uniform (PSF)
a to 10' 9"
9'
16.0
- FXT. WALL
warrants that the sizing of Its
oftwam. Use of this software
assure that this calculation Is
facilities are third -party certif
n accordance with applicable
dimensions and
19
System: Wall
Member Type: Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
o circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
he overall project Accessodzs (Rim Board, aocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by IQC-FS under evaluation reports ESR -1153 and ESR -1387
For wren ode evaluation reports, Weyerhaeuser product literature and installation details refer to
support Information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Mike A
DCA
(562)382-8040
magullar@dca-se.com
6/10/202110:35:03 PM UTC
ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16
Way"hocuscr File Name: 21-166 VOVAN RESIDENCE
Page 14 / 14
N,
II II I
II � II I
II w II I
I I
I I II I
I J II I
I r I I I
I �9� II II II
JJL��� II II II
�I II II
I Ipr o a —1
I II i
I II I
I II I
r�
IF J0� L°J
I it
r I
LJ j
L°J
I
� I
QOV
ANN �
a
9d
I 1%
V0 UG
I odg�8€3Ct �� I
I I
DAVID CHOI & ASSOCIATES
1327 LOMA
Long Beach, CA 90804
PAD FOOTINGS
FTG: F1
P1 = 0.466 K
P2 = 0 K
P3 = 0 K
P4 = 0 K
PTOTAL = 0.466 K
PALLOW. = 5.4 K USE: TYPE PAD FTG.
F- 0 1
0
0
O
CF -1
LOADING:
D L
ROOF: ( 17 + 20 )
FLOOR: ( 15 + 40 )
WALL: ( 16 + 0 )
B= 358.5 plf = 0.24 ft
1500 psf
DAVID CHOI & ASSOCIATES
CONTINUOUS FOOTINGS
TRIB
x 5 ft
= 82.5
+
100
x 0 ft
= 0
+
0
x 11 ft
= 176
+
0
w
= 258.5
+
100
=r 358.5 plf
1'-0" WIDE FTG.
USE:
David Choi & Associates
CONT. FTG. CAPACITY (CF -1)
39.5 in
EFFECTIVE BEARING AREA
(Width) (Eff. Length)
A = 12 (18+ 3.5+ 18) = 3.29 ff
144
ALLOWABLE BEARING PRESSURE
q = 1500 Psf
(SOILCAPACITY) (SELF WEIGHT)
PA = 1500 ( 3.29) - 150 ( 3.29 x 1,5) = 4.19 K
1000
PA = 4.19 kips
18 in
David Choi & Associates
(E) CONT. FTG. CAPACITY (ECF -1)
39.5 in
EFFECTIVE BEARING AREA
(Width) (Eff. Length)
A = 12 (18+ 3.5+ 18) = 3.29 fe
ALLOWABLE BEARING PRESSURE
q = 1500 psf
(SOIL CAPACITY) (SELF WEIGHT)
PA = 1500 ( 3.29) - 150 ( 3.29 x 1.5) = 4.19 K
1000
PA = 4.19 kips
18 in
6/3/2021
U.S. Seismic Design Maps
1510 Sandcastle Dr, Corona Del Mar, CA 92625, USA
Latitude, Longitude: 33.6046599, -117.8563952
S L Concepts
m
t
Z
�l
tiet
Ctio'�gle
Blue Ke
N�
F
00
f�
n OC
n
'k,
O
OSH PD
Date
6/3/2021 9:42:45 AM
Design
Code Reference Document
ASCE7-16
Risk Category
If
Site Class
D - Default (See Section 11.4.3)
-Type
Value
Description
Ss
1.325
MCER ground motion. (for 0.2 second period)
S1
0.47
MCER ground motion. (for 1.Os period)
SMS
1.591
Site -modified spectral acceleration value
SM1
null -See Section 11.4.8
Site -modified spectral acceleration value
SDs
1.06
Numeric seismic design value at 0.2 second SA
SD1
null -See Section 11.4.8
Numeric seismic design value at 1.0 second SA
Type
Value
Description
SOC
null -See Section 11.4.8
Seismic design category
F➢
1.2
Site amplification factor at 0.2 second
Fv
null -See Section 11.4.8
Site amplification factor at 1.0 second
PGA
0.576
MCEG peak ground acceleration
FPGA
1.2
Site amplification factor at PGA
PGAM
0.691
Site modified peak ground acceleration
TL
8
Long -period transition period in seconds
SsRT
1.325
Probabilistic risk -targeted ground motion. (0.2 second)
SsUH
1.45
Factored uniform -hazard (2% probability of exceedance in 50 years) spectral acceleration
SsD
2.631
Factored deterministic acceleration value. (0.2 second)
S1 RT
0.47
Probabilistic risk -targeted ground motion. (1.0 second)
S1UH
0.509
Factored uniform -hazard (2% probability of exceedance in 50 years) spectral acceleration.
SID
0.828
Factored deterministic acceleration value. (1.0 second)
PGAd
1.062
Factored deterministic acceleration value. (Peak Ground Acceleration)
CRs
0.914
Mapped value of the risk coefficient at short periods
CR1
0.924
Mapped value of the risk coefficient at a period of 1 s
https://seismicmaps.org 112
DAVID CHOI & ASSOCIATES
21-166 VOVAN RESIDENCE
SEISMIC BASE SHEAR
(ASCE 7-16)
(Table 20.3-1) SITE CLASS: D
(Table 12.2-1) R = 6.5
Ss = 1.33 g
(11.4-3)
(12.8-7)
(12.8-1)
(12.8-7)
(12.8-6)
SMs = Fa Sa
1.20 x 1.33
1.59
St = 0.47 g
(11.4-2) SMi = F„ St
= 1.73 x 0.47
0.8131
SDs = (2/3)SMs (11.4-4) SDI = (2/3)SMt
= (2/3) x 1.59 = (2/3)x 0.8131
= 1.060 g = 0.542 g
Ta = Ct h,x
= 0.02 x 8 0.75
0.09514
V = Cs W
VMIN = 0.044SMIX = 0.0466 >_ 0.01 W
VMIN = 0.5 St W (For Si >_ 0.6g)
Seismic Values 1 of 1
= 0.5
x
0.470
=
0.036 W
W
6.5
/
1.0
VMIN
= 0.047
W
(12.8-3)
VMAx
= SDI I@
=
0.542
x 1.0 = 0.8766 W
W
W
(T • R)
0.095
x 6.5
(12.8-2)
V
= SDs
W
=
1.060 x W 0.164 W <--GOVERNS
(R/la)
6.5
/ 1.0
(12.8-7)
V
= CS • p
W
=
0.164
:; x 1 W = 0.164 W
V
= 0.164
W
[LRFD]
V =
0.7
x
0.164
W
V
= 0.12
W
[ASD]
Seismic Values 1 of 1
DAVID CHOI & ASSOCIATES
WEIGHT
ROOF
Wroof = ( 15 psf +
Wwall = 16 psf x
-166 VOVAN RESIDENCE
SEISMIC ANALYSIS
3.0 psf ) x 4058 ff2 = 73.0 kips
8 ft /2 x 325 ft = 20.8 kips
W -ROOF = 93.8 kips
W -TOTAL = 93.8 kips
BASE SHEAR
VBASE = 0.12 x WTOTAL [ASD]
VBASE = 0.115 x 93.8 = 10.79 kips
DISTRIBUTION OF BASE SHEAR
Floor W (k) H(ft) WH % V: F (kips) lbs/sq ft
ROOF 93.8 8 751 1.00 x 10.8 10.79 (2.659)
Sum= 751 Sum = 10.79
DIAPHRAGM FORCES
Floor
Fp, fp s
Fpx min (psf)
Fpx max (psf)
Use: F,x
ROOF
2.659
4.903
9.805
4.903
Seismic Loads 1 of 1
DAVID CHOI &
ASSOCIATES
INPUT DATA
PROJECT:
CLIENT:
JOB NO.:
DATE:
Exposure category (9, C or DI
Roof angle 6 = 6.88
B
9 = 0.00
Importance factor
I =
1.00
Category 11
Basic wind speed
V =
110
mph
Topographic factor
K, =
1
Flat
Building height to eave
he =
8
It
Building height to ridge
hr =
11.5
ft
Building length
L =
80
ft
Building width
B =
58
It
Effective area of components
A =
60
fl?
DESIGN SUMMARY
Max horizontal force normal to building length, L, face
Max horizontal force normal to building length, B, face
Max total horizontal torsional load
ANALYSIS
Velocity Pressure
ql, = 0.00256 Kh K, Ka V21 = 18.43 psf
where: qh = velocity pressure at mean roof height, In.
Kh = velocity pressure exposure coefficient evaluated at height, h,
Ka = wind directionality factor
In - mean roof height
Design Pressures for MWFRS
p = qh [(G Cpr)-(G CPI N
where: p = pressure in appropriate zone
G CPf = product of gust effect factor and external pressure coefficient
G CPI = product of gust effect factor and internal pressure coefficient
0.18 or -0.18
a= width of edge slaps, MAX[ MIN(0.1 B, OAh), 0.048,3] _
Net Prasanros: In<Fl. Ra=tc I nad Ca<se
PAGE:
DESIGN BY:
9.20 kips x 0.6 = 5.52 kips
= 7.62 kips x0.6= 4.57 kips
68.98 ft -kips
63.82 kips
j,-0 E = 10.79 kips
l SEISMIC GOVERNS
0.70
= 0.85
= 9.75 ft
< 60 It, [Satisfactory]
3.90 It
Net Pressures lost). Torsional Load Cases
Roof angle 6 = 6.88
Roof angle
9 = 0.00
Surface
Surface
Net Pressure with
IT
Net Pressure with
1.09 2.75
G CPf
GePf
(+GCPI) (-GCPI)
(+GCPI) (-GCPI)
1
0.42
4.36 10.99
0.40
4.05 10.69
2
-0.69
-16.03 -9.40
-0.69
-18.03 -9.40
3
-0.38
-10.39 -3.76
-0.37
-10.14 -3.50
4
-0.31
-8.99 -2.35
-0.29
-8.66 -2.03
1E
0.63
8.36 15.00
0.61
7.93 14.56
2E
-1.07
-23.04 -16.40
-1.07
-23.04 -18.40
3E
-0.55
-13.46 -6.82
-0.53
-13.09 -6.45
4E
-0.46
-11.73 -5.09
-0.43
-11.24 -4.61
5
-0.45
-11.61 4.98
-0.45
-11.61 -0.98
6
-0.45
-11.61 1 498 1
-0.45
1 -11.61 1 4.98
PAGE:
DESIGN BY:
9.20 kips x 0.6 = 5.52 kips
= 7.62 kips x0.6= 4.57 kips
68.98 ft -kips
63.82 kips
j,-0 E = 10.79 kips
l SEISMIC GOVERNS
0.70
= 0.85
= 9.75 ft
< 60 It, [Satisfactory]
3.90 It
Net Pressures lost). Torsional Load Cases
E 3 2
2E 2 3 2E 2 3 2 ZONE 2/I) BOUNDARY
SE Ji J ZE Ji 2i
3 J 2i J
4�_ !6 IE 4�`aT 2E 2 4`_4i
�� y 9f�� 6 �� 6 4E„�
0
5 5 5 5 IE
REFERENCE CORNER IE REFERENCE CDRNER IE REFERENCE CORNEA IE REFERENCE CORNER
bWNo DIRECTION ° d WIND DIREC➢ON u aWIRD DIRECOON WIND DIRECTION
Transverse Direction Longitudinal Direction Transverse Direction Longitudinal Direction
Basic Load Cases Torsional Load Cases
Roof angle
6 = 6.88
GCPr
Net Pressure with
Surface
(+GCpi) (-GCPI)
IT
0.42
1.09 2.75
2T
-0.69
4.01 -2.35
3T
-0.38
-2.60 -0.94
4T
-0.31
-2.25 -0.59
Roof angle
0 = 0.00
GCPr
Net Pressure
with
Surface
(+GCPI)
(-GCRI)
1T
0:40
1.01
2.67
2T
-0.69
-4.01
-2.35
3T
-0.37
-2.53
-0.88
4T
-0.29
-2.17
-0.51
E 3 2
2E 2 3 2E 2 3 2 ZONE 2/I) BOUNDARY
SE Ji J ZE Ji 2i
3 J 2i J
4�_ !6 IE 4�`aT 2E 2 4`_4i
�� y 9f�� 6 �� 6 4E„�
0
5 5 5 5 IE
REFERENCE CORNER IE REFERENCE CDRNER IE REFERENCE CORNEA IE REFERENCE CORNER
bWNo DIRECTION ° d WIND DIREC➢ON u aWIRD DIRECOON WIND DIRECTION
Transverse Direction Longitudinal Direction Transverse Direction Longitudinal Direction
Basic Load Cases Torsional Load Cases
Basic Load Cases in Transverse Direction
Torsional Load Cases in Transverse Direction
Basic Load Cases in Longitudinal Direction
Area
Pressure (k) Win
Surfacece
(az)
(+GCPI)
(-GCPJ
1
578
2.52
6.35
2
2109
-33.82
-19.82
3
2109
-21.92
-7.92
4
578
-5.19
-1.36
1E
62
0.52
0.94
2E
228
-5.25
-3.74
3E
228
-3.07
-1.55
4E
62
-0.73
-0.32
-0.30
Horiz.
7.27
7.27
E
Vert.
-63.59
-32.80
10 psf min.
Horiz.
9.20
9.20.
Sec. 6.1.4.1
Vert.
-46.40
46.40
Torsional Load Cases in Transverse Direction
Basic Load Cases in Longitudinal Direction
Torsional Load Cases in Lonaitudinal Direction
Area
Pressure(k)with
Torsion(ft-k)
Surface
(ft')
(+GCPJ
(-C'CPi)
1
499
2.03
5.34
2
2023
-32.43
-19.01
3
2023
-20.50
-7.08
4
499
-4.33
-1.01
1E
66
0.52
0.96
2E
314
-7.24
-5.15
3E
314
-4.11
-2.03
4E
66
-0.74
-0.30
2E
Horiz.
7.62
7.62
E
-16
3E
228
-3.07
Veda
-63.82
-33.04
10 per min.
Horiz.
5.66
5.66
Sec. 6.1.4.1
Vert.
46.40
-46.40
Torsional Load Cases in Lonaitudinal Direction
Area
Pressure (k) with
Torsion(ft-k)
SurfaceArea
(ft')
(+GCPJ
(-C'CPi)
(+GCPJ
(-GCPJ
1
258
1.12
2.83
20
51
2
941
-15.08
-8.84
-33
-19
3
941
-9.77
-3.53
21
8
4
258
-2.31
-0.61
42
11
1E
62
0.52
0.94
19
34
2E
228
-5.25
-3.74
-23
-16
3E
228
-3.07
-1.55
13
7
4E
62
-0.73
-0.32
26
11
1T
320
0.35
0.88
-7
-18
2T
1168
-4.68
-2.75
11
7
3T
1168
-3.04
-1.10
-7
-3
4T
320
-0.19
-14
4
TotaTorslo-0.72
l Hodz. nal Load, Mr
69
69
Torsional Load Cases in Lonaitudinal Direction
Design pressures for components and cladding El s z 3 0 2
rti--r-i
P= 9hI(G CP) - (G CPill
where: pressure on component
s
P=p P iz
Pmin=l0 psf (Sec. 6.1.4.2, pg 21) s 1fr iai
GCP= external pressure coefficient. s~z�sT z"�a
see table below Walls
Roof a17° Roof e»°
Area
PressureI
Torsion
(ft -k
Surface
(ft�
(*GCei)(+GCPJ
Are. (it)
(-GCPI)
1
217
0.88
9
24
2
1708
-27.39
66
38
3
1708
-17.32
-41
-14
4
217
-1.88.
19
4
1E
66
0.52
13
24
2E
314
-7.24
17
12
3E
314
1111
-10
-5
4E
66
-0.74 -0.30
19
8
1T
283
0.29 0.76
4
-10
2T
2023
-8.11 4.75
-39
-23
3T
2023
-5.13 -1.77
25
8
4T
283
-0.61 -0.14
-6
-2
Total
Horiz. Torsional Load, M7
64.6 1
64.8
Design pressures for components and cladding El s z 3 0 2
rti--r-i
P= 9hI(G CP) - (G CPill
where: pressure on component
s
P=p P iz
Pmin=l0 psf (Sec. 6.1.4.2, pg 21) s 1fr iai
GCP= external pressure coefficient. s~z�sT z"�a
see table below Walls
Roof a17° Roof e»°
(Walls reduced 10 %, Fig. 6-11A note 5.)
Camp. & Cladding
Effective
Zone 1
Pressure
Zone 2
Zone 3
Zone 4 Zone 5
N.M.Negaave
Are. (it)
GCP
-GCP
GCP
I -GCP
GCe I -GCe
Gap GC GCP-GCP
Comp.
60
022
-0.92
0.22
-1.26
0.22 -1.48
0.78 -0.87 0.78 -1.01
(Walls reduced 10 %, Fig. 6-11A note 5.)
Camp. & Cladding
I Zone 1 1 Zone 2 1 Zone 3 1 Zone 4
Zone 5
Pressure
PoakWe
Negative Pas- Negative Posaiw NegatWe P --W-
N -9 -ft.
N.M.Negaave
(Psf)
10.00
-20.31 10.00 -26.45 10.00 -30.54 17.63
-19.28
17.63
1 -21.98.
DAVID CHOI & ASSOCIATES
Forces to Shear Wall Lines - X Direction`
ROOF SHEAR ON WALLS �� 3� j 1 j
DAVID CHOI & ASSOCIATES
SHEARWALL TIEDOWN DESIGN
FLOOR 7 SHEAR AND UPLIFT
SW ID
SW length
Top PL.
Height (ft.)
SW Unit
Shear
Roof Trib.
(ft)
Net Uplift
(lbs.)
qTS/HDS
Net Comp.
(lbs.)
HEFFFor
HM (ft.)
2L/H
Adjusted
Shear (plo
WALL
TAG
X1.1
4.42
10.33
737
1
7434
HDU11
7614
10.33
0.86
769
D
X2.1
3.42
10.33
748
1
7588
HDU11
7727
10.33
0.66
857
D
X2.2
4.00
10.33
748
1
7564
HDU11
7727
10.33
0.77
807
D
X3.1
4.00
8.00
496
4
3798
HDU4
3968
8
1.00
496
B
FLOOR 1 SHEAR AND UPLIFT
SW ID
SW length Top L.
SSheaUnit
Roof
Net s) 'ftTATS
/HDS
Ne(P
Fft.r
2L/H
WALL
Height (ff.)
ft)Trib.
lbs.)
HAN (ft.)
Shear (plo
Y1.1
6.00 10.33.
245
2
23
26
HDU2
-- 2527
10.33
1.16
245
A
Y2.1
6.00 8.00
233
5
1590
HDU2
1865
8
1.50
233
A
Holdown Uplift Page 1 of 1
STRUCTURAL CALCULATIONS
Bl11LDING DA11810"'
JUl " '' 8021
VOVAN RESIDENCE
ADDITION AND REMODEL
PLAN (KtctrrALcvLA"v,,S
ADDRESS:
1510 SANDCASTLE DRIVE
CORONA DEL MAR, CA 92625
July 9, 2021
PREPARED BY:
1D
S4784
DAVID CHOI & ASSOCIATES, INC.
JOB # 21-166
BY, F:_r'
-------�r----------r---- -�-----�
I II II II I
I II II � II I
I II II � II I
I II II w II I
Z II I
Z
I II I w
I II I I II � I
I I I I I I S r
I I�I I I I I r
I i I II I®I r
L----� ---J L-------- J L-----�
I IP —
2
I II I
a I IQI , I
y LJ
I II I
I �
rOil I o,
o LJ
IL
I W II u I
--_- --J I-- - r�
L°J
c
I
I I
I � I
I 3 I
W U
\VI I
FTG: F1
P1 =
0.466 K
P2 =
0 K
P3 =
0 K
P4 =
0 K
PTOTAL =
0.466 K
PA«ow. = 5.4 K
F F
P1 =
0.612 K
P2 =
5.38 K
P3 =
0 K
P4 =
0 K
PTOTAL =
5.992 K
PAuow. = 8.4375 K
DAVID CHOI & ASSOCIATES
1327 LOMA
Long Beach, CA 90804
PAD FOOTINGS
USE: TYPE 2.0 PAD FTG.
USE: TYPE PAD FTG.
Title Block Line 1
Project Title:
You can change this area
Engineer:
using the "Settings" menu item
Project ID:
and then using the 'Printing &
Project Descr:
Title Block" selection.
-0.072 in
Title Block Line 6
Printed: 6 JUL 2021, 4:45PM
Beam on Elastic Foundation
Ile: -16 A R IDENC .ec6
Software m ydght ENERCALC, INC. 1963-2020, auild:12.20.5.31
6.918
e.
DESCRIPTION: GB1
CODE REFERENCES
Calculations per ACI 318-14, IBC 2018, CBC 2019, ASCE 7-16
Load Combinations Used : IBC 2018
Material Properties
fc 112-
fr= fc * 7.50
2.50 ksi
= 375.0 psi
ty Density =
145.0 pcf
7v Lt Wt Factor =
1.0
Elastic Modulus =
3,122.Oksi
Soil Subgrade Modulus
Load Combination IBC 2018
6 Phi Values Flexure: 0.90
Shear: 0.750
01 = 0.850
100.0 psi I (inch deflection)
fy - Main Rebar = 60.0 ksi Fy - Stirrups = 40.0 ksi
E - Main Rebar = 29,000.0 ksi E - Stirrups =29,000.0 ksl
Stirrup Bar Size # = # 3
Number of Resisting Legs Per Stirrup 2
Beam is supported on an elastic foundation.
38" w x 18" In
I Span=7.0 ft '�
Details
#1 Reinforcing...,
344 at 3.0 in from Top, from 0.0 to 7.0 ft in this span
Id Loads
Beam self weight calculated and added to loads
Load for Span Number 1
Moment: E = 32.580 k -ft, Location = 3.50 ft from left end of this span
_. --_.._...
s Radtio = 0 346: 1
Section used for this span
Mu : Applied
Mn * Phi: Allowable
Load Combination
Location of maximum on span
Span # where maximum occurs
Typical Section
-16.002 k -ft
46.193 k -ft
+1.20D+0.50L+0.70S+E+1.6
3.459 ft
Span # 1
344 at 3.0 in from Bottom, from 0.0 to 7.0 ft in this span
Service loads entered. Load Factors will be applied for calculations.
Maximum Deflection
Location (ft)
Max Downward L+Lr+S Deflection
0.000 in
Max Upward L+Lr+S Deflection
0.000 in
Max Downward Total Deflection
0.102 in
Max Upward Total Deflection
-0.072 in
Maximum Soil Pressure = 1.473 ksf at 7.00 ft LdComb: E Only
Allowable Soil Pressure = 1.50 ksf OK
Shear Stirrup Requirements
Entire Beam Span Length : Vu < PhiVd2, Req'd Vs = Not Reqd, use stirrups spaced at 0.000 in
Maximum Forces & Stresses for Load Combinations
Luau Wnlmu' UH
Location (ft)
oenaing aaess Kesulrs ( K -H)
Segment Length Span #
in Span
Mu: Max Phi'Mnx Stress Ratio
MAXimum Bending Envelope
Span # 1 1
3.541
16.00 46.19 0.35
+1.40D+1.60H
Span # 1 1
6.918
-0.00 46.19 0.00
+1.20D+0.50Lr+1.60L+1.60H
,Title Block Line 1
Project Title:
You can change this area
Engineer:
using the "Settings" menu item
Project
ID:
and then using the "Printing &
Project
Descr:
Title Block" selection.
Title Block Line 6
Printed:
0 JUL 2021,
4:45PM
Beam on Elastic
Foundation
e: - 66
SIDEN E.ec6
Softwarecoynghl ENERCALC,INC.19S3.2020, 9ui1d:12.20.5.31
e.
DESCRIPTION: GB1
Load Combination
Location (ft)
Bending Stress Results
( k -ft)
Segment Length Span #
In Span
MU: Max
Phi'Mnx
Stress Ratio
Span # 1
1
6.918
-0.00
46.19
0.00
+1.20D+1.60L+0.50S+1,60H
Span # 1
1
6.918
-0.00
46.19
0.00
+1.20D+1.60Lr40.50L+1.60H
Span # 1
1
6.918
-0.00
46.19
0.00
+1.20D+1.60Lr+0.50W+1.60H
Span # 1
1
6.918
-0.00
46.19
0.00
+1.20040.501-+1.60S+1.6011
Span#1
1
6.918
-0.00
46.19
0.00
+1.20D+1.60S+0.50W+1.60H
Span # 1
1
6.918
-0.00
46.19
0.00
+1.20D+0.50Lr40.50L+W+1.60H
Span # 1
1
6.918
-0.00
46.19
0.00
+1.20D+0.50L+0.50S+W+1.60H
Span # 1
1
6.918
-0.00
46.19
0.00
+1.20D+0.50L+0.70S+E+1.60H
Span # 1
1
3.541
16.00
46.19
0.35
+0.90D+W+0.90H
Span # 1
1
6.918
-0.00
46.19
0.00
+0.90D+E+0.90H
Span # 1
1
3.541
16.00
46.19
0.35
Overall Maximum Deflections - Unfactored Loads
Load Combination
Span
Max.
"" Dell Location in Span
Load Combination
Max. "+" Dell
Location in Span
Span 1
1
0.1023
7.000
Span 1
-0.0721
0.000
Detailed Shear Information
Span
Distance
'd'
Vu (k)
Mu
d'Vu/Mu
Phi'Vc
Comment
Phi"Vs
Spacing
(in)
Load Combination Number
(ft)
(in)
Actual Design
(k -ft)
(k)
(k)
Reqd
Suggest
+0.90D+E40.90H
1
0.00
15.00
-0.14
0.14
0.00
1.00
42.86
Vu<PhlVcJ2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
0.08
15.00
-0.46
0.46
0.01
1.00
42.86
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
0.16
15.00
-0.77
0.77
0.05
1.00
42.86
Vu<PhiVcl2
Not Regd
0.00
0.00
+0.90D+E+0.90H
1
0.25
15.00
-1.07
1.07
0.12
1.00
42.86
Vu <PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
0.33
15.00
-1.37
1,37
0.21
1.00
42.86
Vu<PhiVrl2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
0.41
15.00
-1.66
1.66
0.32
1.00
42.86
Vu<PhlVci2
Not Regd
0,00
0.00
+0.90D+E+0.90H
1
0.49
15.00
-1.94
1.94
0.46
1.00
42.86
Vu<PhiVd2
Not Regd
0.00
0.00
+0.90D+E+0.90H
1
0.58
15.00
-2.21
2.21
0.63
1.00
42.86
Vu<PhlVd2
Not Reqd
0.00
0.00
+0.90D+E40.90H
1
0.66
15.00
-2.48
2.48
0.81
1.00
42.86
Vu<PhiVd2
Not Regd
0.00
0.00
+0.900+E+0.90H
1
0.74
15.00
-2,74
2.74
1.02
1.00
42.86
Vu<PhlVd2
NotReqd
0.00
0.00
+0.90D+E40.90H
1
0.82
15.00
-2.99
2.99
1.24
1.00
42.86
Vu<PhIVd2
NotReqd
0.00
0.00
+0.90D+E+0.901-1
1
0.91
15.00
-3.23
3.23
1.49
1.00
42.86
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.900+E+0.90H
1
0.99
15.00
-3.47
3.47
1.76
1.00
42.86
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.90D+E40.90H _
1
1.07
15.00
-3.70
3.70
2.05
1.00
42.86
Vu<PhiVcl2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
1.15
15.00
-0.92
3.92
2.36
1.00
42.86
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
1.24
15.00
-4.13
4.13
2.68
1.00
42.86
Vu<PhiVd2
NotReqd
0.00
0.00
+0.90D+E40.90H
1
1.32
15.00
4.34
4.34
3.02
1.00
42.86
Vu<PhiVd2
Not Reqd
0.00
0.00
40.90D+E+0.90H
1
1.40
15.00
4.53
4.53
3.38
1.00
42.86
Vu <PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
1.48
15.00
4.72
4.72
3.76
1A0
42.86
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
1.56
15.00
-4.90
4.90
4.15
1.00
42.86
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
1.65
15.00
-5.08
5.06
4.56
1.00
42.86
Vu <PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
1.73
15.00
-5.25
5.25
4.98
1.00
42.86
Vu < PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
1.81
15.00
-5.40
5.40
5.41
1.00
42.86
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
1.89
15.00
-5.56
5.56
5.86
1.00
42.86
Vu <PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
1.98
15.00
5.70
5.70
6.32
1.00
42.86
Vu<PhlVc12
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
2.06
15.00
-5.84
5.84
6.79
1.00
42.86
Vu<PhiVd2
Not Reqd
0.00
0.00
40.90D+E+0.90H
1
2.14
15.00
-5.96
5.96
7.27
1.00
42.86
Vu<PhIVd2
Not Reqd
0.00
0.00
+0.90D4E+0.90H
1
2.22
15.00
-6.08
6.08
7.77
1.00
42.86
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
2.31
15.00
-6.20
6.20
8.27
1.00
42.86
Vu<PhIVd2
Not Reqd
0.00
Roo
+0.90D+E4p.90H
1
2.39
15.00
-6.30
6.30
8.78
1.00
42.86
Vu <PhiVc12
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
2.47
15.00
-6.40
6.40
9.30
1.00
42.86
Vu<PhiVd2
Not Reqd
0.00
0.00
Jille Block Line 1
Project Title:
You can change this area
Engineer:
using the "Settings" menu item
Project ID:
and then using the "Printing &
Project Descr:
Title Block" selection.
Comment
Printed: 6 JUL 2021, 4:45PM
Beam on Elastic Foundation rileNERCAUivov
Software coovdaht ENERCALC. INC.
DESCRIPTION: GB1
Detailed Shear Information
Span
Distance
'd'
Vu
(k)
Mu
d'VulMu
Phi'Vc
Comment
Phi'Vs
Spacing (In)
Load Combination
Number
(ft)
(in)
Actual
Design
(k -ft)
(k)
(k)
Reqd
Suggest
+0.90D+E+0.90H
1
2.55
15.00
-6.49
6.49
9.83
1.00
42,86
Vu<PhIVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
2.64
15.00
5.57
6.57
10.37
1.00
42.86
Vu<PhiVcl2
NotRegd
0.00
0,00
+0.90D+E+0.9011
1
2.72
15.00
-6.64
6.64
10.91
1.00
42.86
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
2.80
15.00
-6.71
6.71
11.46
1.00
42.86
Vu<PhiVd2
NotRegd
0.00
0.00
+0.90D+E.0.90H
1
2.88
15.00
-6.77
6.77
12.02
1.00
42.86
Vu<PhiVd2
NotRegd
0.00
0.00
+0.90D+E+0.90H
1
2.96
15.00
5.82
6.82
12.58
1.00
42.86
Vu<PhIVd2
NotRegd
0.00
0.00
+0.90D+E+0.90H
1
3.05
15.00
-6.86
6.86
13.14
1.00
42.86
Vu<PhiVd2
NotRegd
0.00
0.00
+0.90D+E+0.90H
1
3.13
15.00
-6.90
6.90
13.71
1.00
42.86
Vu<PhiVd2
NotRegd
0.00
0.00
40.90D+E+0.90H
1
3.21
15.00
-6.93
6.93
14,28
1.00
42.86
Vu<PhIW2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
3.29
15.00
-6.95
6.95
14.85
1.00
42.86
Vu<PhiVc12
NotRegd
0.00
0.00
+0.90D+E+0.90H
1
3.38
15.00
-6.96
6.96
15.43
1.00
42.86
Vu<PhiVc12
Not Reqd
0.00
0.00
+0.90D+E40.90H
1
3.46
15.00
-6.96
6.96
16.00
1.00
42.86
Vu<PhIVd2
Not Reqd
0.00
0,00
+0.90D+E+0.90H
1
3.54
15.00
-6.96
6.96
16.00
1.00
42.86
Vu<PhiVcJ2
Not Reqd
0.00
U0
+0.90D+E+0.90H
1
3.62
15.00
-6.95
6.95
15.43
1.00
42.86
Vu<PhIVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
3.71
15.00
-6.93
6,93
14.85
1.00
42.86
Vu<PhiVG2
Not Reqd
0.00
0.00
40.90D+E+0.90H
1
3.79
15.00
-6,90
6.90
14.28
1.00
42.86
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0,90H
1
3.87
15.00
-6.86
6.86
13.71
1.00
4286
Vu<PhiVcJ2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
3.95
15.00
5.82
6.82
13.14
1.00
42.86
Vu<PhiVG2
NotRegd
0.00
0.00
+0.90D+E+0.90H
1
4.04
15.00
5.77
6.77
12.58
1.00
42.86
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.90D+E40.90H
1
4.12
15.00
-6.71
6.71
12.02
1.00
42.86
Vu<PhIVa12
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
4.20
15.00
5.64
6.64
11.46
1.00
42.86
Vu <PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
4.28
15.00
-6.57
6.57
10.91
1.00
42.86
Vu <PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
4.36
15.00
5.49
6.49
10.37
1.00
42.86
Vu <PhiVd2
Not Reqd
0.00
0.00
40.90D+E+0.90H
1
4.45
15.00
5.40
6.40
9.83
1.00
42.86
Vu<PhiVcJ2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
4.53
15.00
-6.30
6.30
9.30
1.00
42.86
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
4.61
15.00
-6.20
6.20
8.78
1.00
42.86
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
4.69
15.00
-6.08
6.08
8.27
1.00
42.86
Vu<PhIVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
4.78
15.00
5.96
5.96
7.77
1.00
42.86
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
4.86
15.00
-5.84
5.84
7.27
1.00
42.86
Vu <PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
4.94
15.00
-5.70
5.70
6.79
1.00
4286
Vu <PhiVd2
Not Reqd
0.00
0.00
+0.90D+E40.90H
1
5.02
15.00
-5.56
5.56
6.32
1.00
42.86
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
5.11
15.00
-5.40
5.40
5.86
1.00
42.86
Vu<PhiVd2
Not Reqd
0.00
0.00
+0,90D+E+0.901-1
1
5.19
15.00
-5.25
5.25
5.41
1.00
42.86
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
5.27
15.00
-5.08
5.08
4.98
1.00
42.86
Vu<PhiVd2
Not Reqd
0,00
0.00
+0.90D+E+0.90H
1
5.35
15.00
4.90
4.90
4.56
1.00
42.86
Vu<PhIVd2
Not Reqd
0.00
0.00
+0.90D+E+0,90H
1
5.44
15A0
4.72
4.72
4.15
1.00
42.86
Vu<PhiVd2
NotRegd
0.00
0.00
+0.90D+E+0.90H
1
5.52
15.00
4.53
4.53
3.76
1.00
42.86
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
5.60
15.00
4.34
4.34
3.38
1.00
42.86
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
5.68
15.00
4.13
4.13
3.02
1.00
42.86
Vu<PhiVd2
Nat Reqd
0.00
0.00
+0.90D+E40.90H
1
5.76
15.00
-3.92
3.92
2.68
1.00
42.86
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
5.85
15.00
-3.70
3.70
2.36
1.00
42.86
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
5.93
15.00
-3.47
3.47
2.05
1.00
42.86
Vu<PhiVG2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
6.01
15.00
-3.23
3.23
1.76
1.00
42.86
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.90D4E+0.90H
1
6.09
15.00
-2.99
2.99
1.49
1.00
42,86
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+9.90H
1
6.18
15.00
-2.74
2.74
1.24
1.00
42.86
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
6.26
15.00
-2.48
2.48
1.02
1.00
42.86
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
6.34
15.00
421
2.21
0.81
1.00
42.86
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
6.42
15.00
-1.94
1.94
0.63
1.00
42.86
Vu<PhIVd2
Not Reqd
0.00
0.00
+0.90D+E40.90H
1
6.51
15.00
-1.66
1.66
0.46
1.00
42.86
Vu < PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
6.59
15.00
-1.37
1.37
0.32
1.00
42.86
Vu<PhiVd2
Not Reqd
0.00
0.06
+0.90D+E+0.90H
1
6.67
15.00
-1.07
1.07
0.21
1.00
42.86
Vu<RIM
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
6.75
15.00
-0.77
0.77
0.12
1.00
42.86
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.900+E+0.90H
1
6.84
15.00
-0.46
0.46
0,05
1.00
42.86
Vu<PhIVcJ2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
6.92
15.00
-0.14
0.14
0.01
1.00
42.86
Vu<PhiVd2
Not Reqd
0.00
0.00
Title Block Line 1
Project Title:
You can change this area
Engineer:
using the "Settings" menu item
Project ID:
and then using the "Printing &
Project Descr:
Title Block" selection.
DESIGN SUMMARY
Panted. 9 JUL
Beam on Elastic Foundation
DESCRIPTION: GB2
CODEREFERENCES
Calculations per ACI 318-14, IBC 2018, CBC 2019, ASCE 7-16
Load Combinations Used : IBC 2018
Material Properties
fc - 2.50 ksi m Phi Values Flexure : 0.90
fr= fe * 7.50 = 375.0 psi Shear: 0.750 _ 4
Y Density = 145.0 pcf p t = 0.850 ° z
7v Lt Wt Factor = 1.0 bi z
Elastic Modulus = 3,122.0 ksi $* .
Soil Subgrade Modulus = 100.0 psi /(inch deflection) a r
Load Combination iBC 2018'` s '
fy - Main Rebar = 60.0 ksi Fy -Stirrups = 40.0 ksi
E - Main Rebar = 29,000.Oksi E - Stirrups =29,000.0 ksi
Stirrup Bar Size # _ # 3
Number of Resisting Legs Per Stirrup 2
Beam is supported on an elastic foundation.
Cross Section &
Span #1 Reinforcing....
144 at 3.0 in from Top, from 0.0 to 30.0 ft in this span
oDlied Loads
144 at 3.0 in from Bottom, from 0.0 to 30.0 it in this span
Service loads entered. Load Factors will be applied for calculations.
Beam self weight calculated and added to loads
Load for Span Number 1
Moment: E =15.872 k -ft, Location = 6.0 ft from left end of this span
DESIGN SUMMARY
Maximum Bending Stress Ratio = 0.688:1
Maximum Deflection
Section used for this span Typical Section
Max Downward L+Lr+S Deflection
0.000 in
Mu: Applied 10.566 k -ft
Max Upward L+Lr+S Deflection
0.000 in
Mn * Phi : Allowable 15.353 k -ft
Max Downward Total Deflection
0.023 in
Load Combination +1.20D+0.50L+0.705+E+1.6
Max Upward Total Deflection
-0.010 in
Location of maximum on span 6.353 ft
Span # where maximum occurs Span # 1
Maximum Soil Pressure = 0.337 ksf
at 13.00 ft LdComb: E Only
Allowable Soil Pressure = 1.50 ksf
OK
Shear Stirrup Requirements
Entire Beam Span Length: Vu < PhlVd2, Req'd Vs = Not Reqd, use stirrups spaced at 0.000 in
Maximum Forces & Stresses for Load Combinations
Load Combination Location (ft) Bending Stress Results ( k -ft )
Segment Length Span # in Span Mu: Max Phi'Mnx Stress Ratio
Span # 1 1 6.353 10.57 15.35 0.69
+1.40D+1.60H
Span # 1 1 29.647 -0.00 15.35 0oo
+120D+0.50Lr+1.60L+1.60H
Title Block Line 1
You can change this area
using the "Settings" menu item
and then using the"Printing &
Title Block" selection.
Project Title:
Engineer:
Project ID:
Project Descr:
Printed: 9 JUL 2021, 10:OOAM
Beath on Elastic Foundation rlle:Z1-100VUVANRESIDENUE.006
Software copyright ENERCALC, INC. 19832020, Build:12.20.5.31
r.i r•
e.
DESCRIPTION: DB2
Load Combination Location (ft) Bending Stress Results ( k -ft )
Segment Length Span# in Span Mu: Max Phi"Mnx Stress Ratio
Span # 1
1
29.647
-0.00
15.35
0.00
+1.20D+1.60Lr+0.50L+1.60H
Span # 1
1
29.647
-0.00
15.35
0.00
+1.200+1.60Lr+0,50W+1.60H
Span#1
1
29.647
-0.00
15.35
0.00
+1,20D+0.50L+1.605+1.60H
Span # 1
1
29.647
.0.00
15.35
0.00
+1.20D+1.60S+0.50W+1.60H
Span # 1
1
29.647
-0.00
15.35
0.00
+1.20D+0.5OLr+0.50L+W+1.60H
Span # 1
1
29.647
-0.00
15.35
0.00
+1.20D+0.50L+0.50S+W+1.60H
Span # 1
1
29.647
-0.00
15.35
0.00
+1.20D+0.50L+0.70S+E+1.60H
Span # 1
1
6.353
10.57
15.35
0.69
+0.90D+W+0.90H
Span # 1
1
29.647
-0.00
15.35
0.00
+0.90D+E+0.90H
Span # 1
1
6.353
10.57
15.35
0.69
Overall Maximum Deflections
- Unfactored Loads
Load Combination
Span
Max.
'=" Dell
Location in Span
Load Combination
Max. "+" Dail
LocaOon in Span
Span 1
1
0.0234
13.000
0.0000
0.000
Detailed Shear Information
Span
Distance
'd'
Vu
(k)
Mu
d"Vu1Mu
Phi"Vc
Comment
Phi'Vs
Spacing
(in)
Load Combination Number
(ft)
(in)
Actual
Design
(k -ft)
(k)
(k)
Req'd
Suggest
+0.90D+W+0.90H
1
0.00
15.00
0.04
0.04
0.00
1.00
13.58
Vu<PhiVd2
NotRegd
0.00
0.00
+0.90D+E+0.90H
1
0.35
15.00
-0.15
0.15
0.02
1.00
13.58
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.90D4E+0.90H
1
0.71
15.00
-0.27
0.27
0.09
1.00
13.58
Vu <PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
1.06
15.00
-0.38
0.38
0.20
1.00
13.58
Vu <PhiVG2
Not Recd
0.00
0.00
+0.90D+E+0.90H
1
1.41
15.00
-0.48
0.48
0.34
1.00
13.58
Vu<PhiVc12
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
1.76
15.00
-0.58
0.58
0.53
1.00
13.58
Vu<PhiVd2
NotReqd
0.00
0.00
+0.90D+E+0.90H
1
2.12
15.00
-0.68
0.68
0.75
1.00
13.58
Vu<PhiVG2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
2.47
15.00
-0.76
0.76
1.00
1.00
13.58
Vu<PhiVG2
Not Recd
0.00
0.00
+0.90D+E+0.90H
1
2.82
15.00
-0.85
0.85
1.29
1.00
13.58
Vu<PhiVd2
Not Reqd
0.00
0.00
-490D+E+0.90H
1
3.18
15.00
-0.92
0.92
1.60
1.00
-13.58
Vu <PhiVG2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
3.53
15.00
-0.99
0.99
1.94
1.00
13.58
Vu<PhiVd2
NotRegd
0.00
0.00
+0.90D+E+0.90H
1
3.88
15.00
-1.05
1.05
2.30
1.00
13.58
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
4.24
15.00
-1.10
1.10
2.68
1.00
13.58
Vu<PhIVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
4.59
15.00
-1.15
1.15
3.09
1.00
13.58
Vu < PhiVd2
Not Reqd
0.00
0.00
+0.901)+E+0.901-1
1
4.94
15.00
-1.19
1.19
3.51
1.00
13.58
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
5.29
15.00
-1.23
1.23
3.94
1.00
13.58
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.900+E40.90H
1
5.65
15.00
-1.25
1.25
4.39
1.00
13.58
Vu < PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
6.00
15.00
-1.27
1.27
4.84
1.00
13.58
Vu<PhiVd2
Not Reqd
0.00
0.00
40.901)+E+0.901`1
1
6.35
15.00
-1.28
1.28
10.57
1.00
13,58
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.90D+E40.90H
1
6.71
15.00
-1.29
1.29
10.10
1.00
13.58
Vu<PhiVd2
NotRegd
Uo
0.00
+0.90D+E+0.90H
1
7.06
15.00
-1.29
1.29
9.63
1.00
13.58
Vu<PhiVd2
NotReqd
0.00
0.00
+0.90D+E+0.90H
1
7.41
15.00
-1.28
1.28
9.16
1.00
13.58
Vu<PhiVG2
NotRegd
0.00
0.00
+0.90D+E+0.90H
1
7.76
15.00
-1.27
1.27
8.70
1.00
13.58
Vu < PhiVd2
NotReqd
0.00
0.00
+0.90D+E+0.90H
1
8.12
15.00
-1.25
1.25
8.24
1.00
13.58
Vu<PhIVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
8.47
15.00
-1.23
1.23
7.78
1.00
13.58
VV<PhIVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
8.82
15.00
-1.20
1.20
7.34
1.00
13.58
Vu <PhiVG2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
9.18
15.00
-1.17
1.17
6.90
1.00
13.58
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
9.53
15.00
-1.14
1.14
6.47
1.00
13.58
Vu < PhiVd2
Not Reqd
0.00
0.00
+0.90D+E40.90H
1
9.88
15.00
-1.11
1.11
6.06
1.00
13.58
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.901)+E+0.90H
1
10.24
15.00
-1.07
1.07
5.65
1.00
13.58
Vu<PhIVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
10.59
15.00
-1.03
1.03
5.26
1.00
13.58
Vu<PhIVd2
Not Reqd
0.00
0.00
Title Block Line 1
Project Title:
You can change this area
Engineer:
using the "Settings" menu item
Project ID:
and then using the "Printing &
Project Descr:
Title Block" selection.
Comment
9 JUL 2021, 10:OOAM
Beam on Elastic Foundation
DESCRIPTION: GB2
Detailed Shear Information
Load Combination
Span
Number
Distance
(H)
'd'
(in)
Vu
Actual
(k)
Design
Mu
(k -ft)
d'Vu1Mu
Phi'Vc
(k)
Comment
Phi'Vs
(k)
Spacing (in)
Req'd Suggest
+0.90D+E40.90H
1
10.94
15,00
-0.99
0.99
4.89
1.00
13.58
Vu<PhiVd2
Not-Reqd
0.00
0,00
+0.90D+E+0.90H
1
11.29
15.00
-0.95
0.95
4.52
1.00
13.58
Vu<PhiVc12
Not Reqd
0.00
0.00
+0,90D+E+0.90H
1
11,65
15.00
-0.91
0.91
4.17
1,00
13,58
Vu<PhlVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
12.00
15,00
-0.87
0.87
3.84
1,00
13.58
Vu<PhiVd2
NotRegd
0,00
0.00
+0.90D+E40.90H
1
12.35
15.00
-0.83
0.83
3,51
1.00
13.58
Vu<PhiVcl2
NotRegd
0.00
0.00
+0.90D+E+0.90H
1
12.71
15.00
-0.79
0.79
3.21
1.00
13.58
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
13.06
15.00
-0.74
0.74
2,92
1.00
13.58
Vu<PhiVG2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
13.41
15.00
-0.70
0.70
2,64
1.00
13.58
Vu <PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0,90H
1
13.76
15.00
-0.66
0.66
2.38
1,00
13.58
Vu<PhiVd2
NotRegd
0.00
0.00
+0.90D+E+0.901-1
1
14.12
15.00
-0.62
0.62
2.13
1.00
13.58
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0,90H
1
14.47
15.00
-0.58
0.58
1.90
1.00
13.58
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0,90H
1
14.82
15.00
-0.54
0.54
1.68
1.OD
13.58
Vu<PhiVG2
Not Reqd
0,00
0,00
+0.90D+E+0.901-1
1
15.18
15.00
-0.50
0.50
1.48
1.00
13.58
Vu<PhiVc/2
NotRegd
0.00
0.00
+0.90D+E40,90H
1
15.53
15.00
-0.46
0.46
1.29
1.00
13.58
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
15.88
15.00
-0.43
0.43
1.11
1,00
13.58
Vu<PhiVG2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
16.24
15.00
-0.39
0,39
0.95
1.00
13.58
Vu<PhiVd2
NotRegd
0.00
0.00
+0.90D+E+0,90H
1
16.59
15.00
-0.36
0.36
0.80
1.00
13.58
Vu<PhiVd2
NotRegd
0.00
0.00
+0.900+E+0,9DH
1
16.94
15.00
-0,32
0.32
0.66
1.00
13.58
Vu<PhiVd2
NotReqd
0.00
0.00
+0,90D+E+0.90H
1
.17.29
15.00
429
0.29
0.53
1.00
13.58
Vu<PhiVd2
NotRegd
0.00
0.00
+0.90D+E+0.90H
1
17.65
15.00
-0.26
0.26
0.42
1,00
13.58
Vu<PhlVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
18.00
15.00
-0.23
0.23
0.31
1.00
13,58
Vu<PhiVc/2
NotRegd
0.00
0.00
+0,90D+E+0.90H
1
18.35
15,00
-0.20
0.20
0,22
1.00
13.58
Vu<PhNal2
Not Reqd
0,00
Ho
40.90D+E+0.90H
1
18.71
15.00
-0.17
0.17
0.13
1.00
13.58
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
19.06
15.00
-0.15
0.15
0.06
1,00
13.58
Vu<PhiVd2
NotRegd
0.00
0,00
+0.900+E+0.90H
1
19.41
15.00
-0,12
0.12
0.01
1.00
13.58
Vu<PhiVd2
NotRegd
0.00
0.00
+0.90D+E+0.90H
1
19.76
15.00
-0.10
0.10
0.06
1.00
13.58
Vu<PhiVol2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
20.12
15.00
-0.08
0.08
0.11
1.00
13.58
Vu<PhiVd2
Not Reqd
0.00
0.00
+0,90D+E+0.90H
1
20.47
15.00
-0.06
0.06
0.16
1,00
13.58
Vu<PhiVd2
NotRegd
0.00
Ho
+0,90D+E+0.90H
1
20.82
15A0
-0.04
0.04
0.19
1.00
13.58
Vu <PhiVd2
Not Reqd
0.00
0.00
+0.90D+W+0.90H
1
21.18
15.00
0.04
0.04
0.00
1.00
13.58
Vu < PhlVd2
Not Reqd
0.00
0.00
+0.900+W+0.90H
1
21.53
15.00
0.04
0.04
0.00
1.00
13.58
Vu<PhiVd2
Not Reqd
0.00
0.00
+0,90D+W+0,90H
1
21,88
15.00
0,04
0.04
0.00
1.00
13.58
Vu<PhiVd2
NotRegd
0.00
0.00
40.90D+W40.90H
1
22.24
15.00
0,04
0.04
0,00
1.00
13.58
Vu < PhiVd2
Not Reqd
0.00
0.00
+0.90D+W40.90H
1
22,59
15.00
0.04
0,04
0.00
1.00
13.58
Vu<PhiVd2
NotRegd
0.00
0.00
+0.90D+E+0.90H
1
22.94
15.00
0.05
0.05
0.27
1.00
13.58
Vu<PhiVd2
NotRegd
0.00
0,00
+0.90D+E+0.90H
1
23.29
15.00
0.06
0.06
0.27
1.00
1358
Vu<PhiVd2
Not Reqd
0.00
0,00
40.90D+E+0.901-1
1
23.65
15.00
0.07
0.07
0.26
1.00
13.58
Vu<PhiVcJ2
NotRegd
0.00
0.00
+0.90D+E40.90H
1
24.00
15.00
0.07
0.07
0.25
1.00
13.58
Vu<PhiVd2
NotRegd
0.00
0.00
+0,90D+E+0.90H
1
24.35
15,00
0.08
0.08
0.24
1,00
13.58
Vu<PhiVcJ2
Not Reqd
0.00
0.00
+0,90D+E+0.90H
1
24,71
15.00
0.09
0.09
0.23
1.00
13.58
Vu<PhiVd2
NotRegd
0.00
0.00
+0.90D+E+0.90H
1
25.06
15.00
0.09
0,09
0.21
1.00
13.58
Vu<PhIVd2
Not Reqd
0,00
0,00
+0,90D+E+0.90H
1
25.41
15.00
0.09
0.09
0.19
1.00
13.58
Vu<PhiVd2
NotRegd
0.00
0.00
+0.901)+E+0.901-1
1
25.76
15.00
0.09
0.09
0.17
1.00
13.58
Vu<PhlVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
26.12
15.00
0.10
0.10
0.15
1.00
13.58
Vu<PhIVd2
Not Reqd
0.00
0.00
+0.900+E40.90H
1
26.47
15.00
0,09
0,09
0.13
1.00
13.58
Vu<PhiVd2
NotRegd
0.00
0,00
+0,90D+E+0.90H
1
26.82
15.00
0.09
0,09
0.11
1.00
13.58
Vu<PhiVa/2
Not Reqd
0.00
0.00
+0,90D+E+0.90H
1
27.18
15.00
0,09
0,09
0.09
1.00
13.58
Vu<PhiVd2
NotRegd
0.00
0.00
40.90D+E+0.90H
1
27.53
15.00
0.09
0.09
0.07
1.00
13.58
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
27.88
15.00
0.08
0.08
0.06
1.00
13.58
Vu<PhiVc12
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
28.24
15.00
0,08
0,08
0.04
1.00
13,58
Vu<PhlVd2
Not Reqd
0,00
0.00
+0.90D+E+0.90H
1
28.59
15.00
0,07
0.07
0.03
1.00
13.58
Vu<PhiVc12
Not Reqd
0,00
0.00
+0,90D+E+0.90H
1
28.94
15.00
0.06
0.06
0.02
1.00
13.58
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
29.29
15.00
0.05
0.05
0.01
1.00
13.58
Vu<PhiVd2
Not Reqd
0.00
0.00
+0.90D+E+0.90H
1
29.65
15,00
0.04
0.04
0,00
1.00
13.58
Vu<PhiVd2
Not Reqd
0.00
0.00
6
J
w
J�
J
d
J7
s
N
DAVID CHOI & ASSOCIATES
Forces to Shear Wall Lines - X Direction
ROOF SHEAR ON WALLS
E = 2.66 psf
Wall ID
Force Abv.
Obs) AREA
F (lbs)
Ftaai (lbs)
Shearwall
Length ft
v=F/b
Maximum Adjusted
Shear h/w
X1
0 135
3609
3609442
1468
816
852
X2
0
5550
5550
7.42
748
857
X3
0 746
1984
1984
1 4.00
496
1 496
Forces to Shear Wall Lines - Y Direction
ROOF SHEAR ON WALLS
E = 2.66 psf
Wall ID
Force Abv.
Obs)
AREA
F(Ibs)
Flt.,
Shearwall
Len th ft
v=F/b
Maximum Adjusted
Shear h/w
Y1
0
552
1468
1468
6.00
245
245
Y2
0
526
1399
1399
6.00
233
233
Y3
-,0
1367
3635
3635
6.00
606
1S06"'
Lo{t0 CDM5lWA'RnN
(0.6 -0,1K SD9)D {- a,.qE
Unit Shear
DAVID CHOI & ASSOCIATES
SHEARWALL TIEDOWN DESIGN
FLOOR 1 SHEAR AND UPLIFT
SW ID
SW length
Top PL.
Height (ft.)
SW Unit
Shear
Roof Trib.
(ft)
Net Uplift
(lbs.)
ATS/HDS
Net Comp.
(Ibs.)
HEFFFor
HM/(ft.)
2L/H Adjusted
Shear(pif)
WALL
TAG
X1.1
4.42
10.33.
816
1
8254
HDU11
8434
10.33
0.86
852
D
X2.1
3.42
10.33
748
1
7588
HDU11
7727
10.33
0.66
857
D
X2.2
4.00
10.33.
748
1
7564
HDU11
7727
10.33
0.77
807
D
X3.1
4.00
8.00
496
4
3798
HDU4
3968
8
1.00
496
B
FLOOR 1 SHEAR AND UPLIFT
Z�
SW ID
SW length
Top PL.
Height (ft.)
SW Unit
Shear
Roof Trib.
(ft)
Net Uplift
(lbs.)
ATS/HDS
Net Comp,
(lbs.)
HEFF For
H/W (ft.)
2LIH Adjusted WALL
Shear (plf) TAG
Y1.:1
6.00
10:33
2451-.
2
2263
-. HDU2'
- 2527
10:33
1.16 .245. A
1
6.00
8.00
233
5
1590
HDU2
1865
8
1.50 233 A
6.00
` 8.00 -
- `606.
3
4613
1 HDU5'1
4847
1 8
1:50 ' . 606 C . .
Loki) Co�lpitwp�TYt1aV
(0,6 -9.1615o0 1,5 k b}g
Holdown Uplift Page 1 of 1