NOTICE OF INCOMPLETE COASTAL DEVELOPMENT
PERMIT APPLICATION FILING
(Via Email)
March 31, 2021
Sinclair Associates Architects Inc.
ATTN: Robert Sinclair
10956 Weyburn Avenue
Los Angeles, CA 90024
rsinclair@sinclairearc.com
Application No.
• Divided Sky SMKJ LLC CDP
• CDP2021-010
(PA2021-055)
Address 1 Collins Island
Please be advised that after reviewing the subject application, your submittal has been
deemed incomplete and further information is required before we are able to proceed
with the application process.
The following documentation is required to complete the application:
1. Property Development Standards.
Please be advised, the project as designed does not comply with all required property
development standards identified in Newport Beach Municipal Code (NBMC)
Chapter 21.30 (Property Development Standards). Reference the attached plan
check correction sheet for a list of the required changes.
FYI: THE BELOW ITEMS WERE SUBMITTED, BUT NEED TO BE UPDATED WITH 2021
NAVD NUMBERS AND LOW RISK AVERSION PROJECTIONS.
2. Coastal Hazards Report.
As the property is located on the shoreline, the proposed development may be
affected by current or expected future erosion, flooding/inundation, wave runup, or
wave impacts, including those resulting from sea level rise. Please provide a Coastal
Hazards Report prepared in accordance with Newport Beach Municipal Code
(NBMC) Section 21.30.015(E)(2).
March 9, 2021
(PA2021-055)
Page 2
FYI: The Report should be updated to reflect 10.9 NAVD88
7.7 feet NAVD88 (current historical max. sea level for Port of LA) + 2.9 feet NAVD88
(low risk aversion projection, high risk scenario interpolated for 75 years) = 10.9 feet
NAVD88
3. Bulkhead Condition Report.
As the property contains a bulkhead, a Bulkhead condition report is required. The
report is required to be prepared by in accordance with Newport Beach Municipal
Code Section 21.30.015(E)(3). In addition to the other requirements the report must
include an analysis of whether the existing bulkhead is required to protect the existing
principal structure.
Please be aware, a Waiver of Future Protection will likely be required as a condition
of approval for this project in accordance with Section 21.30.015(E)(5). This is a
recorded agreement waiving any potential right to future protection devices to
address threats from natural hazards for the economic life of the development.
4. Waiver of Future Protection.
Notice: As a condition of approval of new development, an agreement in favor of the
City is necessary waiving any potential right to future protection to address situations
in the future in which development is threatened with damage or destruction from
waves, erosion, storm conditions, landslides, seismic activity, bluff retreat, sea level
rise, or other natural hazards.
5. Digital Copy of Plans
Please provide a digital copy of the Geotechnical Investigation report. (Can be
emailed.)
Need to only resubmit 1 hard copy of full-size plans and 1 copy of 11x17 plans.
Please email a digital copy of the 11x17 plans as well.
6. Digital and Hard Copies of Updated Reports
Upon verification of completion, the application will be processed and scheduled for a
Zoning Administrator Hearing. Should you have any questions regarding submittal
requirements, please contact Afshin Atapour, Planning Technician at 949-644-3212 or
aatapour@newportbeachca.gov.
Attachments: Plan Check Corrections
March 9, 2021
(PA2021-055)
Page 3
Residential Zoning Corrections
Community Development Department
Planning Division
100 Civic Center Drive; P.O. Box 1768
Newport Beach, CA 92658
949-644-3200
www.newportbeachca.gov
Plan Check No.: PA2021-055
Address: 1 Collins Island
Date: 3/31/2021
Corrections Required Contact Information
“1” (First Review): 03/31/21
“2” (Second Review):
“3” (Third Review):
If you have questions regarding your plan check, please contact:
Plan Checker: Afshin Atapour
Email/Phone: aatapour@newportbeachca.gov - 949-644-3212
Please contact me to discuss corrections prior to resubmitting.
GENERAL INFORMATION
1. Zone: R-1 Setback Map No: S-4 PC Text:
2. Proposal: New Addition Alteration Other
3. No. of Units Allowed: 1 No. of Units Proposed: 1
4. Demo Proposed Yes No If Yes, number of units to be demolished 1
COASTAL COMMISSION REVIEW
5. Coastal Zone: Yes Exclusion Zone No
6. Exempt because:
7. Categorical Exclusion No.: Effective Date:
8. Waiver No: Effective Date:
9. AIC No: Coastal Development Permit No: Effective Date:
10. Coastal Approval Letter (all pages) to be scanned into plans.
11. Comments:
DISCRETIONARY ACTION
12. Application required: Reason:
13.
Previous Discretionary Approvals:
1. Application Type No. For:
2. Application Type No. For:
3. Application Type No. For:
4. Application Type No. For:
5. Application Type No. For:
14. Please make an appt with: Phone: Email:
15. Scan approval letter / resolution (including conditions) into plan sets. Copy attached
16. HOLD ON FINAL. The following items must be completed before the building permits are finaled:
17. Comments:
Residential Zoning Corrections (Cont’d)
Updated: 01/20/2021 I:\Users\PLN\Shared\PA's\PAs - 2021\PA2021-055\1st Check\PA2021-055 - Corrections.docx (pw_CDD)
Page 2 of 10
Residential Zoning Corrections (Cont’d)
Updated: 01/20/2021 I:\Users\PLN\Shared\PA's\PAs - 2021\PA2021-055\1st Check\PA2021-055 - Corrections.docx (pw_CDD)
Page 3 of 10
REQUIRED FEES
18. Fairshare Fee Contribution: 19. San Joaquin Hills Transportation Corridor Fee:
20. Other:
LOT OR PARCEL STATUS
21. 1 Legal Description: Lot: 1 Block: Section: Tract: 01723
22. Easement(s) on-site: Yes No Verify with Public Works
23.
No person shall develop any structure including, but not limited to, a principal or accessory structure across a lot
line per Section 19.04.035 (Development Across Property Lines) of the Subdivision Code. Please apply for a
Parcel Map, Lot Merger, Lot Line Adjustment, or Certificate of Compliance to address underlying legal lot
lines.
24. Comments: 1.) Easement is private.
SETBACKS
25. 1
Setback Regulations (20.30.110)
*Setbacks are measured from property line to finished surface, unless otherwise specified.
Front: 7 Left Side: 4 Right Side: Rear: 4 Other:
26. 1
Third Floor Step-backs (20.48.180A.2.c.) (Applicable to single- and two-unit dwellings in the R-1, R-2, R-BI,
and RM zoning districts )
Front: 15 Left Side: 2 Right Side: Rear: 15 N/A:
• Enclosed floor area and covered decks located on the third floor shall be stepped back a minimum of 15 feet
from the front and rear setback lines.
• For lots 30 feet in width or greater, a minimum step back of 2 feet from each side setback line shall also be
required, including bay windows.
27.
On residential lots wider than thirty (30) feet, if the primary entrance to a dwelling faces a side setback area the
entry door shall be set back a minimum of five feet from the side property line and a three-foot-wide unobstructed
walkway shall be provided up to a minimum height of eight feet between the primary entrance and the public
street or alley.
28.
A minimum thirty-six (36) inch wide passageway shall be maintained within at least one side setback area
adjacent to the principal structure. The passageway shall be free of any encroachments or obstructions from
ground level to a height of eight feet, including mechanical equipment, and other items attached to, or detached
from, the principal structure.
29. 1 Comments: 1.) Encroaching areas not allowed into setback area.
2.) See marked plans.
FLOOR AREA/SITE AREA LIMITATIONS
30. 1 Lot Size: 6772.32 square feet Lot Dimensions: See attached subdivision map with
dimensions
31. 1 Buildable Area: lot area minus required setback areas = 3,456.67
Residential Zoning Corrections (Cont’d)
Updated: 01/20/2021 I:\Users\PLN\Shared\PA's\PAs - 2021\PA2021-055\1st Check\PA2021-055 - Corrections.docx (pw_CDD)
Page 4 of 10
32. 1
Floor Area Limitation: 2 x buildable area + (200 Square Feet for R-BI only) = 6,913.34 maximum square footage
• Calculation includes exterior walls, stairway(s) on first level of occurrence, enclosed spaces (finished or
unfinished) with a ceiling height of 6 feet or greater, daylighting basements, and enclosed parking
(including subterranean)
• Calculation does not include subterranean basements.
• Covered patios must be open on one side on 1st floor and open on at least two sides above first floor,
otherwise area shall be included as floor area.
• Required openings for covered patios may include required safety railings and minimal structural supports.
Railings shall be constructed of transparent material or opaque material that is at least 40% open.
33. Proposed Floor Area: square feet
34.
Site (Lot) Coverage Limitation: percent of total lot area
• Calculation includes the percentage of a site covered by structures, including eaves and overhangs, and
accessory structures and by decks more than 30 inches in height.
35. Proposed Lot Coverage: square feet or percent of total lot area
36. Provide a floor area calculations exhibit (to scale) verifying proposed square footage (show dimensions &
calculations).
37. Comments:
For 38 - 41, applicable to all single- and two-unit dwellings in the R-1, R-2, and R-BI zoning districts, except: lots 25 feet wide or
less in R-2
38. 1
Third Floor Area Limitation (20.48.180.A.2.a)
15% of the total buildable area for lots wider than 30 feet:
Maximum: 0.15 x buildable area = 518 Proposed: 517.97
20% of the total buildable area for lots 30 feet wide or less:
Maximum: 0.20 x buildable area = Proposed:
•
39. Comments:
40. 1
Combined Third Floor Area and Covered Deck Limitation (20.48.180.A.2.b)
50% of the total buildable area:
Maximum: 0.5 x buildable area = 1,728.34 Proposed: Provide
41. 1 Comments: 1.) Provide combined third floor area and covered deck limitation.
For 42-43, applicable to all single- and two-unit dwellings in the R-1, R-2, R-BI, and RM zoning districts, except: lots 25 feet wide
or less in R-2
42. 1
Open Volume Area Required (20.48.180.A.3)
15% of the buildable area of the lot in addition to the required setback areas
Required: 0.15 x buildable area: 518 square feet
Proposed: 1026.70 square feet
• Open volume must be located within the buildable envelope (within the setback; under 24 FEET)
• Open Volume must have a minimum dimension of 5 feet in depth from the setback line on which it is located
• Open volume must be open on a minimum of one side and have minimum clear vertical dimension of 7.5 feet
43. Comments:
PLOT PLAN/SITE PLAN/FLOOR PLANS
Residential Zoning Corrections (Cont’d)
Updated: 01/20/2021 I:\Users\PLN\Shared\PA's\PAs - 2021\PA2021-055\1st Check\PA2021-055 - Corrections.docx (pw_CDD)
Page 5 of 10
44. Provide fully dimensioned Site Plan and Floor Plans.
45. Show the location of all buildings on-site and dimension distance to property lines.
46. Dimension the distance from face of curb to front property line (verify with Public Works).
47. Indicate the second and third floor footprints (if applicable).
48. 1 Dimension all projections (e.g., fireplaces, bay windows, eaves), label distance(s) to property lines.
49. Provide separate existing and proposed floor plans fully dimensioned showing all room uses for all buildings on-
site. Existing floor plans shall illustrate walls to be demolished
50. Plot property lines on site plan and all floor plans with setbacks dimensioned.
51. Indicate the location of easement(s) plotted on site plan.
52. 1
Comments: 1.) Dimensionthe the BBQ counter in the front yard. Freestanding
barbecues with a maximum height of forty-two inches (not including the barbecue
hood) shall be allowed to encroach into the required front setback area, provided
the total length of the barbecue and counter does not exceed six feet.
2.) Provide heights of all gates in setback areas.
3.) Provide heights of property line walls.
4.) Provide heights of spa bench/wall.
5.) Provide dimensions of all roof overhangs. Max is 2'-6".
6.) Provide heights of all planting areas.
7.) 2nd floor structure encroachments not allowed in setback areas.
8.) Section on precise grading plan (C2) is not consistent with design of spa on
site plan (A-4.1)
9.) Sheet A-1.1, zoomed area of seawall/bulkhead is not consistent with
seawall/bulkhead drawings from sewall plans.
10.) Sheet A-4.2, make a note to not be enclosed or used as third floor floor
area.
11.) Sea wall plans need to be updated with 10.9 from 10.65. Reports to be be
updated as well.
12.) Remove guest parking from plans.
13.) See marked plans.
Residential Zoning Corrections (Cont’d)
Updated: 01/20/2021 I:\Users\PLN\Shared\PA's\PAs - 2021\PA2021-055\1st Check\PA2021-055 - Corrections.docx (pw_CDD)
Page 6 of 10
OFF-STREET PARKING (20.40)
Single-Unit Dwellings – Attached 2 per unit in a garage
Single-Unit Dwellings – Detached and less than 4,000 sq. ft.
of gross floor area*
2 per unit in a garage
Single-Unit Dwellings – Detached and 4,000 sq. ft. or
greater of gross floor area*
3 per unit in a garage
Single-Unit Dwellings – Balboa Island 2 per unit in a garage
Two-Unit Dwellings 2 per unit; 1 in a garage and 1 covered or in a garage
Other:
*Gross Floor Area in this case shall include the square footage of basements, but shall not include the square footage of
garages.
Minimum Interior Dimensions
The minimum interior dimensions for parking spaces in residential zoning districts shall be as provided below (unless
otherwise stated in a Planned Community). The Director may approve a reduced width for duplex units when two separate
single car garages are proposed side by side and the applicant has proposed the maximum width possible.
Lot Width Single Car/Tandem* Two Car Three Car
30 feet or less 9’-3” x 19’ (35’)* 17’-6” x 19’ -
30.1 - 39.99 feet 10’ x 19’ (35’)* 18’-6” x 19’ 26’-9” x 19’
40 feet or more 10’ x 20’ 20’ x 20’ 28’-3” x 20’
* The minimum depth for a 2-car tandem space is 35 feet
53. Gross Floor Area for purposes of calculating the number of parking spaces:
Gross Floor Area (don't include garage) + Basement =
54. 1 Number of Parking Spaces Required: 3 Minimum interior clear dimensions required: 28'-3" x 20'
55. Label interior clear dimensions of the garage free of all obstructions such as cabinetry, appliances, steps, posts,
etc. (one riser is allowed, maximum 6 inches high, encroaching no more than 18 inches into garage).
56. Indicate on the plans that the garage doors are automatic roll-up doors. Garages with doors that face the street
that are located within twenty (20) feet of the front property line are required to be equipped with automatic roll-up
doors.
57. Development on lots with alley access shall be designed such that parking is accessed from alley to minimize or
eliminate curb cuts. Exceptions permitted only in compliance with Council Policy L-2; and for properties in coastal
zone, compliance with Section 21.40.070.B and C required.
58. Comments:
HEIGHT LIMITATION (20.30.060)
• 20.30.050 Grade Establishment
• Measured from average grade if slope is 5% or less
• Roofs over the Flat Roof Limit must have a minimum 3:12 pitch
• Sloped roofs with a pitch less than 3:12 and parapets, railings, etc are considered flat roof for the purpose of height limits
• Heights are measured to the top of all finished materials.
• Height certification will be required in some cases
59. 1 Flat Roof Limit: 24 feet Sloped Roof Allowable Ridge Height: 29 feet
60. 1 Height certification inspection required? Yes No If so, add note to elevations stating Height Certification
Required.
Residential Zoning Corrections (Cont’d)
Updated: 01/20/2021 I:\Users\PLN\Shared\PA's\PAs - 2021\PA2021-055\1st Check\PA2021-055 - Corrections.docx (pw_CDD)
Page 7 of 10
61. Provide topographic survey (stamped and signed by a licensed surveyor) to establish slope and average grade or,
use subdivision grading plan, if applicable.
62. Provide a sheet showing the outline of the proposed structure over a topographic survey to verify determination
of slope and grade to be used for measuring height.
63.
Provide slope of the lot. The slope of a lot shall be determined using a four-sided polygon that most closely
approximates the actual footprint of the proposed structure. The area of the four-sided polygon shall not be smaller
than the footprint of the proposed structure and shall be located entirely within the buildable area of the lot. Identify
the elevation points from survey and distance used to calculate slope.
64.
Establishment of Grade (Five Percent or Less Slope)- The grade of the surface from which structure height is
measured shall be a plane established using the average of the elevations at each corner of the four-sided
polygon. Example: A + B + C + D = X; X/4 = Established grade elevation from which to measure structure height.
Identify the four points used to determine grade plane on site plan and illustrate average grade calculation.
65.
Establishment of Grade (More than Five Percent Slope)- The established grade from which structure height is
measured shall be a plane established by determining the elevation of the lot at five evenly spaced points along
each of the two side property lines and connecting each of the points along a side property line with the
corresponding point on the opposite side property line. The five evenly spaced points along each side property
line shall be located so that one point is located at the intersection of the front setback line with the side property
line and another point is located at the intersection of the rear setback line with the side property line. The other
three points along the side property line shall be located so that all five points are equidistant from each other.
Provide a grade plane exhibit per the methodology above and clearly identify the survey points used to
establish the grade plane.
66. Label the established grade on all elevation sheets.
67. For lots with a more than 5 percent slope, plot roof plan over established grade plan exhibit to assist with
determination of grade points located directly below ridge peaks, roof areas and/or parapets.
68. Label interpolated grade points (based on established grade plane) below any critical ridge, parapet, etc.
69. 1 Dimension heights from established grade to: top of flat roof ridge peak all roof top equipment
deck rails any flat elements
70. 1 All new structures shall have a minimum top of slab elevation of 9.0 (88 NAVD datum) pursuant to Section
20.30.060.B.3. When the top of slab is required to be raised, the height of the principal building shall be
measured from the 9.0 (88 NAVD datum) elevation.
71. Provide a complete roof plan.
72. Label roof pitches on roof plan and elevations.
73. Label and dimension eave overhang to property line on all exterior elevations.
74. 1
Comments: 1.) Sheet A-1.0 A , map is upside down.
2.) Dormer pitches are inconsistent with elevations. See marked plans.
3.) Dimension distance between property lines and trellis. Must be 24" away from
property lines, may encroach up to 2'-6".
4.) Dimension trellis encroachment.
5.) Label elevations east, west, north, south instead of left, right, front, rear.
EXCEPTIONS TO HEIGHT LIMITS (20.30.060 D)
75.
Interior Fireplaces- The overall chimney height for an interior fireplace is permitted to exceed the height limit by
two feet above the roof plane plus an additional two foot maximum for the cap/spark arrestor. The additional two
foot section is not only limited in height but also to 2 feet by 4 feet in width and depth. In addition, the chimney
must be located a minimum distance of 10 feet from the nearest roof plane. Label dimensions of the chimney
plus any portion of the cap/arrestor.
Residential Zoning Corrections (Cont’d)
Updated: 01/20/2021 I:\Users\PLN\Shared\PA's\PAs - 2021\PA2021-055\1st Check\PA2021-055 - Corrections.docx (pw_CDD)
Page 8 of 10
76.
Elevator Shafts/Enclosed Stairwells- Flat roofs above elevator shafts and enclosed stairwell housings may
exceed the allowed height limit up to the maximum height for a sloped roof, provided they do not exceed thirty
(30) square feet in area. Label applicable elevator shaft/enclosed stairwell dimensions and area.
77. Comments:
LANDSCAPING
78. 1
LANDSCAPING – TITLE 14
Chapter 14.17 of the Municipal Code (Water-Efficient Landscaping) applies to landscape installation projects
requiring a ministerial or discretionary permit and exceed the following thresholds:
1. New landscape project with greater than 500 square feet of landscape area
2. Rehabilitated landscaped project with greater than 2,500 square feet of landscape area
New Landscape Project:
? total sq ft of new landscaped area
Provide Landscape Documentation Package prepared in accordance with Design Standards or, if landscape
area is 2,500 square feet or less, comply with the Prescriptive Compliance Option (Appendix H of Design
Standards).
Rehabilitated Landscape Project:
total sq ft of rehabilitated landscaped area
1. Provide Landscape Documentation Package prepared in accordance with Design Standards or;
2. Rehabilitated projects with replacement plantings with equal or less water need than the existing landscaping
and the irrigation system is designed, operable and programmed to comply with the City’s water conservation
regulations are exempt from the ordinance and the requirement to provide a complete landscape documentation
package. To qualify for this exemption, the applicant must provide a landscape and irrigation plan and letter from
a licensed professional stating that the replacement landscaping and irrigation system complies with the terms
of this exemption.
79. 1 Comments: 1.) Provide total landscape square footage and show compliance with
standards.
80.
LANDSCAPING – TITLE 20 (20.36.050A)
Impervious surfaces in R-1 and R-2 zones.
1. Impervious surface areas, excluding driveways, shall not exceed 50 percent of the front yard area with
the remaining area landscaped with plant material. The use of pervious materials for walkways,
porches, and outdoor living areas is allowed.
2. Where the typical neighborhood pattern of front yards has been developed with hardscaped outdoor
living areas that exceed the 50 percent maximum for impervious surfaces the Director may waive this
requirement.
Project complies with: No.1 Yes No
No.2 Yes No
81.
Comments:
DESIGN CRITERIA (20.48.180 B.)
For 78-83 below, applicable to all single-unit and two-unit residential building citywide
82.
Walls: Long unarticulated exterior walls are discouraged on all structures. The visual massing of a building should
be reduced by incorporating appropriate design elements; including variation in the wall plane, building modulation,
opening, recesses, vertical element, varied textures, and design accents (e.g. moldings, pilasters, etc.). Front
facades shall include windows.
Residential Zoning Corrections (Cont’d)
Updated: 01/20/2021 I:\Users\PLN\Shared\PA's\PAs - 2021\PA2021-055\1st Check\PA2021-055 - Corrections.docx (pw_CDD)
Page 9 of 10
83.
Upper floors: Portions of upper floors should be set back in order to scale down facades that face the street,
common open space, and adjacent residential structures. Upper story setbacks are recommended either as full
length “stepbacks” or partial indentations for upper story balconies, decks, and/or aesthetic setbacks.
84. Architectural treatment: Architectural treatment of all elevations visible from public places, including alleys, is
encouraged. Treatments may include window treatments, cornices, siding, eaves, and other architectural features.
85.
Front façade: Where the neighborhood pattern is for the primary entrance to face the street, the primary entry and
windows should be the dominate elements of the front façade. Primary entrances should face the street with a
clear, connecting path to the public sidewalk or street. Alternatively, entry elements may be visible from the street
without the door necessary facing the street.
86. Main entrance: The main dwelling entrance should be clearly articulated through the use of architectural detailing.
87. Comments:
MISCELLANEOUS ITEMS
88.
TWO- TO FOUR-UNIT DWELLING PROJECTS A notice shall be signed by property owners and copied into the
plan set prior to the issuance of a building permit for development of two- to four-unit dwellings. The notice serves
as a record of acknowledgement that property owners understand should they choose to pursue the approval of a
Parcel Map for condominium purposes during the construction, they fully understand that the Parcel Map
application is a discretionary process and is not guaranteed.
89.
CONDOS - (Existing Structures) Before a condominium unit may be sold, a condominium conversion building
permit must be signed off by the Planning Department. The Parcel Map must be signed off by the Public Works
Department, approved by the County and RECORDED at the County. Proof of recordation will be required before
Planning can sign off on the building permit final. Provide a copy of the first page of the recorded document.
90.
CONDOS - (New Structures) Before a condominium unit may be sold, a building permit is required for a
description change from “duplex” to “condominiums.” Before building permits can be finaled, the Parcel Map must
be signed off by the Public Works Department, approved by the County and RECORDED at the County. Proof of
recordation will be required before Planning can sign off on the description change. Provide a copy of the first page
of the recorded document.
91.
20.30.130 (Traffic Safety Visibility Area):
Design includes accessory improvements and/or landscaping within traffic safety visibility triangle: Yes No
• If Yes, label and illustrate traffic safety visibility triangle as follows:
• Label proposed improvements and heights within triangle as follows:
92.
20.30.020.A (Screening of Roof-Mounted and Ground-Mounted Mechanical Equipment)- The screening of
mechanical equipment is required in all zoning districts at the time of new installation or replacement. Roof-
mounted and ground-mounted mechanical equipment (e.g., air conditioning, heating, ventilation ducts and
exhaust vents, swimming pool and spa pumps and filters, transformers and generators, and similar equipment,
but excluding solar collectors and related equipment), shall be screened from public view and adjacent
residential districts, and shall comply with the requirements:
93. 1 ACCESSORY STRUCTURES Accessory structures, including fences, hedges, walls, and retaining walls, are
typically limited to 6 feet in side and rear setbacks and 42 inches in front setbacks. Please label height from
natural grade below to highest point of structure.
94. FYI
ASSOCIATION APPROVAL (ADVISORY) Issuance of a Building Permit by the City does not relieve applicant of
legal requirement to observe covenants, conditions and restrictions which may be recorded against the property
or to obtain community association approval of plans.
95. TRASH AREA Indicate the location of the screened trash area on the site plan or floor plan.
96. Comments:
GENERAL NOTES
Residential Zoning Corrections (Cont’d)
Updated: 01/20/2021 I:\Users\PLN\Shared\PA's\PAs - 2021\PA2021-055\1st Check\PA2021-055 - Corrections.docx (pw_CDD)
Page 10 of 10
97. 1
Add the following note(s) as indicated below:
“Pools, spas, walls, fences, patio covers and other freestanding structures require separate reviews and
permits.”
“Fences, hedges, walls, retaining walls, guardrails and handrails or any combination thereof shall not exceed
42 inches from existing grade prior to construction within the required front setback area(s).”
Accessory Living Areas- “There shall be no facilities used for food preparation within or be used for
residential purposes separately or independently from occupants of principal structure.”
Other:-
HOLD ON FINAL
98. FYI
The following Hold(s) on Final will be applied to your building permit:
Height Certification of critical roof height elevations.
Condominium Conversions- Parcel Map recordation.
New Condominiums (1-4 units) - Parcel Map recordation and issuance of Description Change permit
Landscape Certification- For projects requiring landscape documentation package, applicant must provide third-
party stamped and signed Certificate of Completion (Appendix E of Design Standards), Third Party Audit, and
Post-Installation Irrigation Schedule and Maintenance Schedule.
Accessory Dwelling Units: Deed Restriction and Affordability Questionnaire Other:-
99.
Comments: 1.) See marked plans.
2.) Need to only resubmit 1 hard copy of full-size plans and 1 copy of 11x17
plans. Please email a digital copy of the 11x17 plans as well.
3.) Please return marked plans when submitting new set.