Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
F2022-0218 - Misc
X2022-028 IGHiLIGHTED SET W" IN Mow U1,- • UL Certificate • Cut sheets and California Fire Marshal listings for: NEWPORT BEACH FIRE DEPT SIRE PREVENTION DIVISION MARINER SHORES APR 25 2022 BUILDING #6 By la 1179, 1181,1183y 1185, 1187 & 1189 WINSLOW LANE NEWPORT BEACH, CA 92660 Installation Company: oC.R SYSTEMS CSCR SYSTEMS INC 1835 CAPITAL STREET CORONA, CA. 92880 PHONE (951) 270-0255 C10 LIC. #483303 uApplicant ID No: 257057-001 Service Center No:1 Expires: 01 -JAN -2023 CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY that the Alarm Service Company indicated below is included by Underwriters Laboratories Inc. (UL) in its Product Directories as eligible to use the UL Listing Mark in connection with Certificated Alarm Systems. The only evidence of compliance with UL's requirements is the issuance of a UL Certificate for the Alarm System and the Certificate is current under UL's Certificate Verification Service. This Certificate does not apply in any way to the communication channel between the protected property and any facility that monitors signals from the protected property unless the use of a UL listed or Classified Alarm Transport Company is specified on the Certificate. Listed Service From: LAKE FOREST, CA Alarm Service Company: (257057-001) ADVANCED PROTECTION INDUSTRIES LLC, DBA NATIONAL MONITORING CENTER 25341 COMMERCENTRE DR LAKE FOREST CA 92630 Service Center: (257057-001 ADVANCED PROTECTION INDUSTRIES LLC, DBA NATIONAL MONITORING CENTER 25341 COMMERCENTRE DR LAKE FOREST CA 92630 The Alarm Service Company is Listed in the following Certificate Service Categories: File - Vol No. CCN Listing Category BP21121-1 MVDO Managed Video Services S36356-1 UUFO Hosted Central Station S8126-1 UUFX [Signal and Fire Alarm Equipment and Services] (Protective Signaling Services) Central Station ***THIS CERTIFICATE EXPIRES ON 01 -JAN -2023*** "LOOK FOR THE UL ALARM SYSTEM CERTIFICATE" DF -52416:1) • A3-20 (" S,SUD�EWS-10UD(E) Series �Fire-LiTeALa"mS E�ue Zone F��e Alarm Control_ Panel' Ten Zone Fire Alarm Control Panel hV Hnnp-VWAll General The MS-5UD-3(E) is a five -zone FACP (Fire Alarm Control Panel) and the MS-10UD-7(E) is a ten -zone FACP. These con- trol panels provide reliable fire signaling protection for small to medium-sized commercial, industrial, and institutional build- ings. Both panels include built-in communicators for Central Station Service and remote upload/download. Each of these FACPs is compatible with System Sensor's microprocessor -based is series detectors. These conventional smoke detectors can transmit maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory "freeze" signal when the ambient temperature falls below the detector rating. Additionally, both the MS-5UD-3 and MS- 10UD-7 are compatible with conventional input devices such as two- and four -wire smoke detectors, pull stations, waterflow devices, tamper switches, and other normally -open contact devices. Refer to the Fire -Lite Device Compatibility Document for a complete listing of compatible devices. Outputs include four NACs (Notification Appliance Circuits), three programmable Form -C. relays (factory programmed for Alarm, Trouble, and Supervisory) and 24 VDC special applica- tion resettable and nonresettable power outputs. The FACPs supervise all wiring, AC voltage, battery level and telephone line integrity. Activation of a compatible smoke detector or any normally - open fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicating LED, sound the piezo sounder at the FACP, activate the communicator and FACP alarm relay, and operate an optional module used to notify a remote station or initiate an auxiliary control function. New options include a UL listed printer, PRN -6F and FireLite's IPDACT Internet Monitoring module. The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD per- mit monitoring of alarm signals over the Internet saving the monthly cost of two telephone lines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line. NOTE: The MS-5UD-3E and MS-10UD-7E offers the same fea- tures as the MS-5UD-3 and MS-10UD-7 but allow connection to 240 VAC. Unless otherwise specified, the information in this data sheet applies to both the 120 UAC and the 240 UAC versions of these panels. NOTE: For ULC -listed models, see DF -60440. Features • Listed to UL Standard 864, 9th edition. • Built-in DACT (Digital Alarm Communicatodfransmitter). • Style B (Class B}IDC (IN itatmg D,evlpe Cltcu,o_1 7 MS S�(1D 3:1 hve )U¢s4 — MS-10UD-7 - ten IDCs • Style Y (Class B) NAC (Notification Appliance Circuit) - spe- cial application power — MS-5UD-3 - four NACs. — MS-10UD-7 - four NACs. • Notification Appliances may be programmed as — Silence Inhibit. — Auto -Silence. —Strobe Synchronization for System Sensor, Wheelock, Gentex, Faraday, or Amseco devices. —Selective Silence (horn -strobe mute). — Temporal or Steady Signal. — Silenceable or Nonsilenceable. • Optional CAC -5X Style 2 (Class A) Converter Module for NACs and IDCs (2 required for MS-10UD-7). • Form -C Relays for Alarm, Trouble and Supervisory -.Con- tact Ratings 2.0 A@ 30 VDC or 0.5 A @ 30 VAC (resistive). ;e 040 A,totaf systern cbrieht for,M$ - - - • 7.0 A total system current for MS-10UD-7. • Optional Dress Panel DP -51050 • Optional Trim Ring TR -CE for semi -flush mounting. • PR'utllt'opgr6f0ri.', • Low AC voltage sense. • Alarm Verification. • PAS (Positive Alarm Sequence). • Automatic battery trickle charger. • Up to eight ANN -BUS annunciators: — Optional 8 zone Relay Module ANN-RLY. — Optional LED Annunciator Module ANN -LED, — Optional Remote Annunciator ANN -80. — Optional Remote Printer Gateway ANN-S/PG. — Optional LED Annunciator Driver ANN -1/0. • Optional 4XTMF module (conventional reverse polarity/city box transmitter). PROGRAMMING AND SOFTWARE: • Can be programmed at the panel with no special software or additional equipment. • Programmable Make/Break Ratio. • Upload/Download (local or remote) of program and data via integral DACT. DF -52416:1).07/26/2010 — Page 1 of 4 USER INTERFACE: • Built-in DACT (Digital Alarm Communicator/Transmitter). • Integral 80 -character LCD display with backlighting and keypad. • Real-time clock/calendar with automatic daylight savings adjustments. • ANN -BUS for connection to remote annunciators. • Audible or silent walk test capabilities. • Piezo sounder for alarm, trouble, and supervisory. Controls and Indicators LED INDICATORS • FIRE ALARM (red) • SUPERVISORY (yellow) • TROUBLE (yellow) • AC POWER (green) • ALARM SILENCED (yellow) CONTROL BUTTONS • ACKNOWLEDGE • ALARM SILENCE Left Side • SYSTEM RESET (lamp test) • DRILL Terminal Blocks AC Power - TBt: • MS-5UD-3 (FLPS-3 Power Supply): 120 VAC, 50/60 HZ, 1.00 A. • MS-5UD-3E (FLPS-3 Power Supply): 240 VAC, 50 HZ, 0.54A. • MS-10UD-7 (FLPS-7 Power Supply): 120 VAC, 50/60 HZ, 3.80 A. • MS -1 OUD-7E (FLPS-7 Power Supply): 240 VAC, 50/60 HZ, 2.20 A. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Supervised, nonpower -limited. ;eillern-%ede ad'��a)y7 �1z) • Maximum Charging Circuit - Normal Flat Charge: 27.6 VDC @ 1.4 A. Supervised, nonpower -limited. • )1AalarhurEF'...-CYLS er.G�(acit� 18AH`pattcty,toi2v15UD) *00and 26 AH battery for MS-10UD-7(E). [Two 18 Ah bat- teries can be housed in the FACP cabinet. Larger batteries require separate battery box such as the BB -26 or BB -55.] a'4nkT'`te�'^gc64,% ,47� �. r �. trmc 2s�, i�S Depth =5.207 (13.23 cm) Top �_ �,,< �u bWs.� �.���'��s�ay*�p ��• O• irL µt�•a`nY• •68�q�6<4 Door = 19.26' (48.92 cm) Backbox = 19.0' (48.26 cm) Page 2 of 4 — DF -52416:D • 07/26/2010 _Door = 16.821' (42.73 cm )i Backbox = 16.65' (42.29 cm) Bottom Cabinet Measurements Depth - I�.257"_�I (13.353 cm) Right Side Minimum8atterySizg:7AH' Initiating Device Circuits — TB4 (and TB 6 on MS-10UD-7 only): • Alarm onES 1 5pJ1 TB'�1 (FA 5UD-3-;and MS-10UD-7). • Alarm Zones 6 - 10 on TB6 (MS-10UD-7 only). • Supervised and power -limited circuitry. • OpOlrijl ri:,All zones Style 8 (Class Bj.: • Normal Operating Voltage: Nominal 20 VDC. • Alarm Current: 15 mA minimum. • Short Circuit Current: 40 mA max. • Maximum Loop Resistance: 100 ohms. • End of Lute,".: Resistor.K ohm) 1/2 watt (P/N 71252 UL - listed). • Standby Current: 2 mA. Refer to the Fire -Lite Device Compatibility Document for listed compatible devices. Notification Appliance Circuits — TB5 (and TS 7 on MS- 10UD-7 only): • Four NACs • Operation: Style Y (Class B) • Special Application power • Supervised and power -limited circuitry • Normal Operating Voltage: Nominal 24 VDC • Maximum Signaling Current: 3.0 A for MS-5UD-3, 2.5 A maximum per NAC; 7.0 A for MS-t0UD-7(E), 3.0 A maxi- mum per NAC. • End -of -Line Resistor: 4.7K ohm, 1/2 watt (Part #71252) • Max. Wiring Voltage Drop: 2 VDC Refer to the Fire -Lite Device Compatibility Document for com- patible listed devices. Form C Relays — T88: • Relay 1 (factory default programmed as Alarm Relay) • Relay 2 (factory default programmed as fail-safe Trouble Relay) • Relay 3 (factory default programmed as Supervisory Relay) Special Application Resettable Power -TB9: • Jumper selectable by JP31 for resettable or nonresettable power. • Operating voltage: 24 VDC nominal. • Maximum available current: 500 mA - appropriate for pow- ering four -wire smoke detectors. Power -limited circuit. Refer to the Fire -Lite Device Compatibility Document for listed compatible devices. Remote Sync Output - TB2: Remote power supply synchro- nization output, only required for the MS-5UD-3. 24 VDC nom- inal special application power. Maximum current is 40 mA. End -of -Line Resistor: 4.7K ohm. Supervised and power -lim- ited circuit. Product Line Information �)YIS-SIyD-3 ,Five zone, _?,r -Mott FIrk alarm, ,Control Paileh, (includes backbox, FLPS-3 power supply, technical manual, and a frame & post operating instruction sheet). 120 VAC operation. MS-5UD-3E: Same as MS -51.0-3 except for 240 VAC opera- tion. MS-10UD-7: Ten -zone, 24 -volt Fire Alarm Control Panel (includes backbox, FLPS-7 power supply, technical manual, and a frame & post operating instruction sheet). MS-10UD-7E: Same as above with 240 VAC FLPS-7 IPDACT, IPDACT-212UD Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to primary and secondary DACT tele- phone output ports for internet communications over customer provided ethernet internet connection. Requires compatible Teldat Visoralarm Central Station Receiver. Can use DHCP or static IP. (See data sheet DF-60407formore information.) IPBRKT: Mounting kit for IPDACT in common enclosure. IPSPLT: Y Adaptor option to allow connection of both panel dialer outputs to one cable input to IPDACT (sold separately). OPTIONAL MODULES CAC -5X: Optional (Class A) Converter Module. Converts Style B (Class B) Initiating Device Circuits to Style D (Class A); and Style Y (Class B) Notification Appliance Circuits to Style Z (Class A). Connects to J2 on the MS-5UD-3 and MS-10UD- 7(E) main circuit board and to J7 on the MS-10UD-7(E). NOTE., Two Class A Converter Modules are required for the ten - zone panel. 4XTMF: Transmitter module. Provides a supervised output for local energy municipal box transmitter and alarm and trouble reverse polarity. Includes a disable switch and disable trouble LED. A module jumper option allows the reverse polarity circuit to open with a system trouble condition if no alarm conditions exists. Mounts to the main circuit board connectors J4 and J5. �16 1 l {hPAXIBLE ANl lUNF1AT9RSl FAS�N-80 f4ehlote LCD�Anpunci0f6c3Mimics the information displayed on the FACP's LCD. Red. (For white, order: ANN - 80 -W.) ANN -LED: LED Annunciator with three LEDs for each zone: Alarm, Trouble, and Supervisory. Mounts in the DP -51050(B) dress panel. Red. (For white, order ANN -LED -W.) ANN -BLED: LED Annunciator with three alarm (red) indica- tors for up to 30 input zones or addressable points. (Red. For white, order ANN -LED -W.) (See DF -60241). ANN-RLY: Relay module. Mounts inside the cabinet. Provides ten Form C relays. ANN-S/PG: Serial/parallel printer gateway. Provides a connec- tion for a serial or parallel printer. ANN -1/0: Driver module. Provides connections to a user -sup- plied graphic annunciator. ACCESSORIES DP -51050: Optional dress panel. Restricts access to the sys- tem wiring while allowing access to the membrane switch panel. BB -26: Battery backbox, holds up to two 25 AH batteries and CHG-75. BB -55: Battery backbox, holds up to two 25 AH batteries. TR -CE: Optional trim -ring for semi -flush mounted cabinets. PRN -6F: UL listed printer. DF -524160 • 0712612010— Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity • Annunciators......................................................................8 Electrical Specifications (,_.MS5Up,-�., i(FLPS±� Power_, Supply) X120 VAC, 6Q H?'; • MS-10UD-7 (FLPS-7 Power Supply): 120 VAC, 60 HZ, 3.90 A • MS-5UD-3E (FLPS-3 Power Supply): 240 VAC, 50 HZ, 0.54 A. • MS-10UD-7E (FLPS-7 Power Supply): 240 VAC, 50 HZ, 2.20 A. • Wire size: minimum 14 AWG (2.0 mm2) with 600 V insula- tion, supervised, nonpower -limited Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR -CE): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Dimensions: — 20.00" (50.80 cm.) high — 22.5" (57.15 cm.) wide — 8.5" (21.59 cm.) deep. Weight: 27 lb (12.20 kg) Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 — 49°C/32 — 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 — 27°C/60 — 80°F. Agency Listings and Approvals The listings and approvals below apply to the basic MS-5UD-3 and MS-10UD-7 control panels. In some cases, certain mod- ules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for lat- est listing status. • UL Listed: File S624 • FM Approved C CSFM"7.65 0075:0214) • MEA: MEA: 333-07-E NOTE: For ULC -listed models, see DF -60440. NFPA Standards The MS-5UD-3(E) and MS-10UD-7(E) complies with the fol- lowing NFPA 72 Fire Alarm Systems requirements: — LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). — AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). — REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) — PROPRIETARY (Automatic, Manual and Waterflow). — CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). — OT, PSDN (Other Technologies, Packet -switched Data Network) FlreLlte® Alarms and System Sensor® are registered trademarks of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. '® We cannot cover all specific applications or anticipate all requirements. MULOSYSWWBMMU All specifications are subject to change without notice. UUSLITT SYSTEMS Made in the U.S. A. For more information, contact Fire -Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4 — OF -52416:0.07/26/2010 Section 7: Power Supply Calculations 7.1 Overview This section contains instructions and tables for calculating power supply currents in alarm and standby conditions. This is a four -step process, consisting of the following: 1. Calculating the total amount ofAC branch circuit current required to operate the system 2. Calculating the power supply load current for non -fire and fire alarm conditions and calculating the secondary (battery) load 3. Calculating the size of batteries required to support the system if an AC power loss occurs 4. Selecting the proper batteries for your system 7.2 Calculating the AC Branch Circuit The control panel requires connection to a separate, dedicated AC branch circuit, which must be labeled FIRE ALARM. This branch circuit must connect to the line side of the main power feed of the protected premises. No other non -fire alarm equipment may be pow- ered from the fire alarm branch circuit. The branch circuit wire must run continuously, without any disconnect devices, from the power source to the control panel. Overcurrent protection for this circuit must comply with Article 760 of the National Electrical Codes as well as local codes. Use 14 AWG (2.00 mm2) wire with 600 volt insulation for this branch circuit. Use Table 7. 1, to determine the total amount of current, in AC amperes (A), that must be supplied to the system. Device Type Number of Current Draw Total Current per Devices (AC amps) Device MS-51JD-3/MS-10UD-3 1 X 1.00 _ or MS-5UD-7(C)/MS-10UD-7(C) 3.90 or MS-51JD-3E/MS-101JD-3E 0.54 or MS-51JD-7E/MS-101JD-7E 2.20 [ ] X [ ] X Sum Column for AC Branch Current Required = Table 7.1 AC Branch Circuit Requirements 7.3 Calulatirl 7.3.1 Overview The control panel must be able to power all internal and external devices continuously during the non -fire alarm condition. To calculate the non -fire alarm load on the system power supply when primary power is applied, use Calculation Column I in Table 7.3 on page I11. The control panel must support a larger load current during a fire alarm condition. To calculate the fire alarm load on the power supply, use Calculation Column 2 in Table 7.3 on page 111. The secondary power source (batteries) must be able to power the system during a primary power loss. To calculate the non -fire alarm load on the secondary power source, use Calculation Column 3 in Table 7.3 on page Ill. When calculating current draw and the battery size, note the following: • `Primary' refers to the main power source for the control parrel • `Secondary'refers to the control panel's backup batteries • All currents are given in amperes (A). Section 7.2 shows how to convert milliamperes and microamperes to full amperes. To convert... Multiply Example Milliamperes (mA) to mA x 0.001 3 mA x 0.001 = 0.003A amperes (A) Microamperes (PA) to hlAx 0.000001 300 PA x 0.000001 = 0.0003 A amperes (A) Table 7.2 Converting to Full Amperes 7.3.2 How to Use Table 7.3 on page 111 to Calculate System Current Draw Use Table 7.3 on page 111 to calculate current draws as follows: 1. Enter the quantity of devices in all three columns 2. Enter the current draw where required. Refer to the Device Compatibility Document for compatible devices and their current draw 3. Calculate the current draws for each in all columns 4. Sum the total current for each column 5. Copy the totals from Column 2 and Column 3 to Table 7.4 on page 112 Following are the types of current that can be entered into Table 7.3 on page 111: 110 MS -SLID & MS -LOUD Series Manual -PIN 52626:C7 6/12/2018 Calculating the System Current Draw Power Supply Calculations ✓ Calculation Column 1 - The primary supply current load that the control panel must support during a non -Fre alarm condition, with AC power applied. ✓ Calculation Column 2 - The primary supply current load that the control panel must support during a fire alarm condition, with AC power applied. ✓ Calculation Column 3 - The standby current drawn from the batteries in a non -fire alarm condition during a loss of AC power. Table 7.3 contains fluce columns for calculating current draws. For maximum output current availability per circuit and per panel, refer to Section 1.2, `Specifications", on page 13. For each column, calculate the current and enter the total (in amperes) in the bottom row. When finished, copy the totals from Calculation Column 2 and Calculation Column 3 to Table 7.4 on page 112. Table 7.3 System Current Draw Calculations If using the Reverse Polarity Alarm output, add 0.005 amps; if using the Reverse Polarity Trouble output, add another 0.005 amps. The current draw shown represents one zone (IDC) on the main circuit board in alarm. One zone consumes 0.040 amps. An ANN -LED is supplied standard with the MS-SUDC and MS-10UDC. Refer to the Device Compatibility Document for standby current. Enter the number of IDCs used minus one. Must use compatible listed Power Supervision Relay. 301tali rerltUf*w1i$WAb21!@_' fl of 87(¢ee(132¢Bmp6tOtj)letuISS D )'"3.28fortheMS-10UD-3(E),7.25fortheMS-SUD- 7(C/E), and 7.28 for the MS-10UD-7(C/E). MS-5UD & MS-10UD Series Manual -PIN 52626:C7 6/12/2018 111 Calculation Column 1 Calculation Column 2 Calculation Column 3 Seegffiar2f �13�iItBdG%ifl? Device Type Primary, Non -Fire Alarm Currentegon¢a1S)r,�io`,'lahn C4tire)_tr (amps)CAMI ) VAM Qty X[currentX[currentdraw] Total Qty Total Qty X[current Total drew]= _ draw]= A jr! 0]ia%il) �9aniJ #u1S-Ti}Ipl 1 X[0.110]= 1 SCjO.9;l.4]r , ' or MS-10UD X[0.133]= X[0.282]1.2= X[0.133]= CAC -5X [ ] X[0.001]= [ ] X[0.001]= [ ] X[0.001]= 4XTMF [ ] X[0.005]= [ ] X[0.011]1= [ ] X[0.005]= 1 max. 1 max. 1 max. ANN -SEC card [ ] X[0.0031= [ ] X[0.003]= [ 1 X[0.003]= 1 max. 1 max. 1 max. X[0.0371= [ 1 $1peb4Q1=..) y li MS-5UD Series Main Circuit Board MS-5UD and MS-LOUD SerlesManual — P/N 52626:B1 6/30/2009 Product Specificatiow Battery (sealed lead acid only) - J12 Maximum Charging Circuit - Normal Flat Charge: 27.6 VDC @ 1.4 amp Supervised, nonpower -limited Maximum Charger Capacity: 18 Amp Hour battery for MS-5UD-3(E), MS- l0UD-3(E) and 26 Amp Hour battery for MS-5UD-7(E), MS -LOUD -7(E) [two 18 Amp Hour batteries can be housed in FACP cabinet. Larger batteries require separate battery box such as BB -26 or BB -55] Minimum Battery Size: 7 Amp Hour (12 Amp Hour for MS-5UD-7C & MS-10UD-7C) Initiating Device Circuits - TB4 (and TB6 on MS -LOUD only) Alarm Zones 1- 5 on TB 4 (MS-5UD and MS -LOUD) Alarm Zones 6 - 10 on TB6 (MS -LOUD only) Supervised and power -limited circuitry Operation: All zones Style B (Class B) Normal Operating Voltage: Nominal 20 VDC Alarm Current: 15 mA minimum Short Circuit Current: 40 mA max. Maximum Loop Resistance: 100 ohms (2,000 ohms per zone for linear heat detection) End -of -Line Resistor: 4.7K Q 1/2 watt (Part #71252) Standby Current: 2 mA Refer to Fire -Lite Device Compatibility Document for listed compatible devices Notification Appliance Circuit(s) - TB5 and TB71 Four NACs Operation: Style Y (Class B) Special Application power Supervised and power -limited circuitry Normal Operating Voltage: Nominal 24 VDC Maximum Signaling Current: 3.0 amps for MS-5UD-3(E), MS-l0UD-3(E) (2.5 amp maximum per NAC); 7.0 amps for MS-5UD-7(E), MS-10UD-7(E) (3.0 amps maximum per NAC) End -of -Line Resistor: 4.7KQ 1/2 watt (Part #71252) Refer to Fire -Lite Device Compatibility Document for compatible listed devices Form -C Relays - Programmable - TB8 Relay 1 (factory default programmed as Alarm Relay) Relay 2 (factory default programmed as fail-safe Trouble Relay) Relay 3 (factory default programmed as Supervisory Relay) Relay Contact Ratings: 2 amps @ 30 VDC (resistive), 0.5 amps @ 30 VAC (resistive) Special Application Resettable Power - TB9 Operating Voltage: Nominal 24 VDC Maximum Available Current: 500 mA - appropriate for powering 4 -wire smoke detectors (see note 1) Power -limited Circuitry Refer to Fire -Lite Device Compatibility Document for compatible listed devices Special Application Resettable or Nonresettable Power - TB9 Operating Voltage: Nominal 24 VDC Maximum Available Current: 500 mA (see note 1) Power -limited Circuitry Jumper selectable by JP31 for resettable or nonresettable power: ✓ Jumper pins 1 & 2 on JP31 for nonresettable power ✓ Jumper pins 2 & 3 on JP31 for resettable power Refer to Fire -Lite Device Compatibility Document for compatible listed devices 1. Total current for resettable power, nonresettable power and Notification Appliance Circuits must not exceed 3.0 amps for the FACP versions which are powered by the FLPS-3 power supply or 7.0 amps for the FACP versions which are powered by the FLPS-7 power supply. 14 MS-5UD and MS -LOUD Series Mamal — P/N 52626:B 1 6/30/2009 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE (§ LISTING No. Page 1 of 1 CATEGORY: �7'I6="FI�ALgRMCONTROLUNIT(C011AERCIf11j LISTEE: One Fire -Lite Place, Northford, CT 06410-1653 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com DESIGN: Mpdel M0` @ 'i'�MS-5UD-3E, MS-5UD-7, MS-5UD-7C, MS-5UD-7E, MS-10UD-3, MS-10UD-3E, MS-10UD-7, MS-10UD-7C AND MS10-UD-7EQFtre alarrt(t cbnUal un(sp++The MS-5UD series has five input zones and the MS-10UD series has ten input zones. Both product lines have four notification appliance circuits, and three relay contact outputs for alarm, trouble and supervisory and include an integral two-line digital alarm communicator transmitter (DACT). The -3 suffix represents the 3 amp total power variant utilizing the FLPS-3 and the -7 suffix represents the 7 amp total power variant utilizing the FLPS-7. The "E suffix represents. 240 V ac 50 Hz rated products. The "C" suffix represents products that have the separately listed ANN -LED annunciator module already installed. * These Models are intended for the following applications: Local, Auxiliary, Remote station, Central Station, and Proprietary. Refer to listee's data sheet for detailed product description and operational considerations. System components: FLPS-3:; Power Supply Module FLPS-7; Power Supply Module 4XTMF; Transmitter Module CAC -5X; Converter Module ANN -LED; Annunciator Module ANN-RLY; Relay Module *ANN -SEC; Secondary ANN -BUS Module *IPDACT; IP Digital Fire Alarm Communicatior RATING: *120 VAC or 230 VAC primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a fire alarm control unit for use with separately listed compatible initiating and indicating devices. Refer to manufacturer's installation manual for details. This control unit meets the requirements of UL Standard 864, 9th edition. NOTE: For Fire Alarm Verification feature (delay of fire alarm), the retard/reset/restart period shall not exceed 30 seconds. *Rev 04-23-15 gt itThis listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 ;UsttrsgExpires June 30, 2022'; Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division ,BAT, Series Batteries; °sealed Lead ,Acid} General BAT Series Batteries feature a new part-numbering/listing sys- tem — providing an improved method of delivery for Fire -Lite - approved sealed lead -acid batteries for all your fire alarm sys- tem needs. Multiple brands of batteries are now offered under generic part numbers, reducing backorder situations and permit- ting us to deliver these products in a more timely fashion. Fire -Lite has approved the multiple brands listed below as pos- sible product shipped for a given part number. Please note that any incoming orders for "PS Series' batteries will be converted to the equivalent BAT Series part numbers. Features • Provide secondary power for control panels. • Sealed and maintenance -free. • Overcharge protected. • Easy handling with leakproof construction. • Ruggedly constructed, high -impact case (ABS, polystyrene, or polypropylene, depending on models). • Long service life. • Compact. design. Part Number Reference DF -52397:A • D-500 F1re-LIT6'ALc'lrMS by Honeywell Agency Listings and Approvals The listings and approvals below apply to BAT Series Batteries. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL Recognized Components: files MH19884 (B & S Bat- tery), MH2O727 (UPG, previously Jolt), MH2O845 (Power - Sonic). 6933k,iW PREVIOUS Part Number OURRENT„'_ Ipalt -- f�u_becj -----° BATTERY DESCRIPTION ALTERNATES APPROVED: manufacturers and P/Ns shipped under BAT P/Ns PS -612 Discontinued N/A NIA PS -695 Discontinued N/A. N/A PS -1242 BAT -1250 12 V, 5 AH, sealed. BP542 (B&B Battery); PS -1250 (Power -Sonic); SA1250 (Jolt) to be replaced with UB1250 (UPG). PS -1250 BAT -1250 12 V, 5 AH, sealed. BP5-12 (B&B Battery); PS -1250 (Power -Sonic); SA1250 (Jolt) to be replaced with UB1250 (UPG). PS -1270 (01AI`-'I'20 d2 V, 7AM seal.... BP7-12 (B&B Battery); PS -1270 (Power -Sonic); SA1272 (Jolt) to be replaced with UB1270 (UPG). PS -12120 BAT -12120 12 V, 12 AH, sealed. BP12-12 (B&B Battery); PS -12120 (Power -Sonic); SA12120 (Jolt) to be replaced with UB12120 (UPG). PS -12170 BAT -12180 12 V, 18 AH, sealed. PS -12180 (Power -Sonic); SAI 2180 (Jolt) to be replaced with UB12180 (UPG). PS -12180 BAT -12180 12 V, 18 AH, sealed. PS -12180 (Power -Sonic); SA12180 (Jolt) to be replaced with UB12180 (UPG). PS -12250 BAT -12260 12 V, 26 AH, sealed. BP26-12 (B&B Battery); PS -12260 (Power -Sonic); SA12260 (Jolt) to be replaced with UB12260 (UPG). PS -12550 BAT -12550 12 V, 55 AH, sealed. PS -12550 (Power -Sonic); XSA12550 (Jolt) to be replaced with UB12550 (UPG). PS -12600 BAT -12550 12 V, 55 AH, sealed. PS -12550 (Power -Sonic); XSA12550 (Jolt) to be replaced with UB12550 (UPG). PS -12750 Discontinued N/A NIA PS -121000 BAT -121000 12 V, 100 AH, gel] cell. PS -121000 (Power -Sonic); XSA121000A (Jolt) to be replaced with UB121000 (UPG). OF -52397:A • 12/29106— Pagel of 10 PAWER.SANIC 4n u, MODEL Nominal Voltage V Nominal Capacity @ 20 hr. rate A.H. Discharge Current @ 20 hr. rate mA DIMENSIONS Width in. mi Depth in. mm. Height in. man. Height over terminal in. mm. Weight lbs. kg. -1260 12 5.0 250 3.54 90 2.76 70 4.02 102 4.21 107 4.1 1.9 12 7.0 325 5.94 151 2.56 65 3.70 94 3.86 98 5.7 2.6 12 12 600 5.94 151 3.86 98 3.70 94 3.86 98 8.8 4.0 KPS 12 18 875 7.13 1812.99 76 6.57 167 6.57 167 12.8 5.8 30°C 12 25 1300 6.89 175 6.54 166 4.92 125 4.92 125 18.7 8.5 12 55 3000 10.25260 6.60 168 8.20 208 9.45 240 39.7 18. 12 100 5000 12.00 305 6.60 168 8.20 208 9.45 240 65.7 29.8 5.513 E 6.0 12 Characteristic Discharge Curves 100% 90% 0 80% 0 70°/ m Y 60% a 0 50% U 40% 0% mi ---i- haun -� Discharge Time @ 20°C (66°F) Effect of Temperature on Capacity 120% 100% 80% IY 2 60% Q v 40 20% 0% ■■■■.••� r ■�!��MEN ssary unlessof capacityuired.5°Cging a ■■ PlanNo before(41°F)is �1■■■■■■■ necessary1p recoverapacity.rge -20" -10° 0° 10° 20° 30° 40° 51 60° Temperature (Degrees C.) 0 14.0 V 13.0 V 0 12.0 V 11.0 V E 10.0 V F 2 4 6 8 10 12 14 16 18 20 Standing Period (Months) ging is NOT ssary unlessof capacityuired.5°Cging before(41°F)is necessary1p recoverapacity.rge rNOT mayto restore40°C capacuy.(104°F) 30°C 20°C (86F) (68°F) NOTbatteriesch this state. 0 14.0 V 13.0 V 0 12.0 V 11.0 V E 10.0 V F 2 4 6 8 10 12 14 16 18 20 Standing Period (Months) u.0 v 8.0 Voil 11 E P 1.2 2.4 6 12 24 36481 2 4 6 810 20 4U MINUTES * HOURS Discharge Time Page 2 of 10 - DF -52397:A • 12/29/06 at left., PS -121000 Shelf -Life and Storage at left: PS -1210000 Discharge Characteristics ■•11.„11■„1110, u.0 v 8.0 Voil 11 E P 1.2 2.4 6 12 24 36481 2 4 6 810 20 4U MINUTES * HOURS Discharge Time Page 2 of 10 - DF -52397:A • 12/29/06 at left., PS -121000 Shelf -Life and Storage at left: PS -1210000 Discharge Characteristics df -52417:c • B-90 The ANN -80 annunciator is a compact, backlit, 80 -character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced condi- tions. The ANN -80 and the FACP communicate over a two -wire serial Interface employing the ANN -BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL -listed, filtered power supply. ANN -80 Is red; for white, order ANN -80-W. The ANN -80 displays English-language text of system point information including device type, zone, independent point alarm, trouble or supervisory status, as well as any custom alpha labels programmed into the control panel. It includes con- trol switches for remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.) Up to eight ANN -80s may be connected to the ANN -BUS of each FACP. No programming is required, which saves time dur- ing system commissioning. Features • Listed to UL Standard 664, 9th Edition. • Backlit 80 -character LCD display (20 characters x 4 lines). • Mimics all display information from the host panel. • Control switches for System Acknowledge, Signal Silence, Drill, and Reset. • Control switches can be independently enabled or disabled at the FACP. • Keyswitch enables/disables controlswitches and mechani- cally locks annunciator enclosure • Keyswitch can be enabled or disabled at the FACP. • Enclosure supervised for tamper. • System status LEDs for AC Power, Alarm, Trouble, Supervi- sory, and Alarm Silence. • Local sounder can be enabled or disabled at the FACP. • ANN -80 connects to the ANN -BUS terminal on the FACP and requires minimal panel programming. • Displays device type identifiers, individual point alarm, trou- ble, supervisory, zone, and custom alpha labels. • Time -and date display field. • Surface mount directly, to wall or to single, double, or 4" square electrical box. • Semi -flush mount to single, double, or 4" square electrical box. Use ANN-SB80KIT for angled view mounting. • Can be remotely located up to 6,000 feet (1,800 m) from the panel. • Backlight turns off during AC loss to conserve battery power but will turn back on if an alarm condition occurs. • May be powered by 24 VDC from the host FACP or by remote power supply (requires 24 VDC). • Up to eight ANN -80s can be connected on the ANN -BUS. Controls and Indicators • AC Power • Alarm • Trouble • Supervisory • Alarm Silenced Specifications • Operating voltage range: 18 VDC to 28 VDC. r Current consumption :@ 24 VDC nominal (filtered and non 'resettable) 40 mA maximum. • Ambient temperature: 32oF to 120oF (0oC to49oC). • Relative humidity: 93% t 2% RH (noncondensing) at 32oC t 2oC (90oF t3oF). • 5.375' (13.65 cm.) high x 6.875" (17.46 cm.) wide x 1.375" (3.49 cm.) deep. • For use indoors in a dry location. • All connections are power -limited and supervised. Agency Listings and Approvals The listings and approvals below apply to the ANN -80. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL: S2424 • FM approved • MEA: 442-06-E The ANN -BUS POWERING THE DEVICES ON THE ANN -BUS FROM AUXILIARY POWER SUPPLY The ANN -BUS can be powered by an auxiliary power supply when the maximum number of ANN -BUS devices exceeds the ANN -BUS power requirements. See the FACP manual for more information. df -52417:c • 05/22/09 — Page 1 of 2 ANN -BUS DEVICE ADDRESSING Each ANN -BUS device requires a unique address (ID Number) in order to communicate with the FACP. A maximum of 8 devices can be connected to the FACP ANN -BUS communication circuit. See the FACP manual for more information. WIRE COMMUNICATIONS CIRCUIT The ANN -80 connects to the FACP ANN -BUS communications circuit. To determine the type of wire and the maximum wiring distance that can be used with FACP ANN -BUS accessory mod- ules, it is necessary to calculate the total worst case current draw for all modules on a single 4 -conductor bus. The total worst case current draw is calculated by adding the individual worst case currents for each module. NOTE: For total worst case current draw on a single ANN -BUS refer to appropriate FACP manual. After calculating the total worst case current draw, the following table specifies the maximum distance the modules can be located from the FACP on a single wire run. The table ensures 6.0 volts of line drop maximum. In general, the wire length is lim- ited by resistance, but for heavier wire gauges, capacitance is the limiting factor. These cases are marked in the chart with an asterisk ('). Maxi- mum length can never be more than 6,000 feet (1,800 m), regardless of gauge used. See table below. WIRE REQUIREMENTS: POWER CIRCUIT • 14 to 18 AWG (0.75 - 2.08 mm2) wire for 24 VDC power cir- cuit is acceptable. Power wire distance limitation is set by 1.2 volt maximum line drop form source to end of circuit. • All connections are power -limited and supervised. • A maximum of eight ANN -80 modules may be connected to this circuit. Communication Pair Wiring Distance: FACP to Last ANN -BUS Module Total Worst Case Current Draw (amps) 22 Gauge 18 Gauge 16 Gauge 14 Gauge 0.100 1,852 ft. 4,688 ft. ' 6,000 ft. -6,000 ft. 0.200 926 ft. 2,344 ft. 3,731 ft. 5,906 ft. 0.300 617 ft. 1,563 ft. 2,488 ft. 3,937 ft. 0.400 463 ft. 1,172 ft. 1,866 ft. 2,953 ft. 0.500 370 ft. 938 ft. 1,493 ft. 2,362 ft. 0.600 309 ft. 781 ft. 1,244 ft. 1,969 ft. 0.700 265 ft. 670 ft. 1,066 ft. 1,687 ft. 0.800 231 ft. 586 ft. 933 ft. 1,476 ft. 0.900 206 ft. 521 ft. 829 ft. 1,312 ft. 1.000 (max.) 185 ft. 469 ft. 746 ft. 1,181 ft. WIRING CONFIGURATION The following figure illustrates the wiring between the FACP and ANN -BUS devices. ANN -BUS and power wiring are supervised and power -limited. ANN -BUS Device MS-9050UD FACP Wiring to ANN -BUS Device ORDERING OPTIONS: ANN -80-W: White, 80 character LCD Annunciator. ANN-SB80KIT-R: Red surface mount backbox with angled wedge. ANN-SB80KIT-W: White surface mount backbox with angled wedge. FlreLlte® Alarms Is a registered trademark of Honeywell International Inc. @2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Page 2 of 2 — df -52417:c • 05/22/09 IS® This document is intended to be used for installation purposes. We try to keep ourur product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. fiill®Bi SKVMW E 11111 TT SYSTEMS All specifications are subject to change without notice. Made in the U.S. A. For more information, contact Fire -Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2 — df -52417:c • 05/22/09 LISTING No. CATEGORY LISTEE: DESIGN: INSTALLATION: MARKING: APPROVAL: L�j CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE '7120 0075+02911 X7920 `ANI�UNCIATd�2Sl Page 1 of 1 lFIR6 LITE ALARMS INC Ohe etre' Lrte f?lacell Northford, CT 06410-1653 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com lviodel /{NN 80 and *ANN 80W,'b"gte fixe aliriupclatgrs Unit is a 80 -character, supervised backlit LCD fire annunciator. Communication between the control panel and the annunciator is accomplished over a two -wire serial interface employing the ANN -BUS protocol. Refer to listee's data sheet for additional detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. Listee's name, product number, electrical rating and UL label. Listed as an annunciators for use separately listed compatible fire alarm control units. Refer to Manufacturers Installation Manual for details. *Rev. 04-28-08 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Lls�inO Expires`. 49",j 22; e v 2`,A1-Do1,f2oA(15"th x 113"11x.1"D) includes: • Threelabels: "Fire Alarm Documents" "As -Built Permits" "Test and Maintenance Documents" • An adjustable bungee allows you to fit various sizes of binders, documents, smoke -cans, etc. • A door bracket holds two CDs, three sets of keys and more documents • A cam lock with two keys ISVA-I )oClinA V!vl=I7�er�Lt� (11"W x 15"H x 4" D) Smaller and more basic model without the door bracket for CDs and key sets. However, it does have the three labels, adjustable bungee and a lock with two keys. Don't see the box you want? Call us or visit our website Customization, special colors, and/or silk-screening of logos are available for quantities of 25 or more. (requires lead time) 800-473-0213 E-mail: info@mierproducts.com TELGUARD TVI 7; IS`� �....i_.UI_.AR AL Al vi TE- i -t R I. i, I_ r W0R�; 5 IP/W TG7LV'F01II ti COMMERCIAL FIRE PRODUCT FEATURES f tCerhfia for use on Verizon's LTE network or long, sunset - free installation. F Meets UL 864 requirements for sole, primary or backup path communications. F Minimizes false alarms by providing dual paths for self -tests. The Telguard TG-7FS LTE -V is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS LTE -V transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2013 Edition of NFPA 72, the TG-7FS LTE -V can serve as the sole communications path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS LTE -V, the monthly communications bill decreases. By being able to signal failures to the centralstation within sixty) ;minutes of an outage, the TG-7FS LTE -V can be installed' as the sole) path for commercial fire installations) For existing installations, all landlines can be swapped for a single TG-7FS LTE -V because of the new sixty minute supervision mode. The TG-7FS LTE -V can also be installed as a backup path and upgraded to sole path at a later date. TELGUARD TG=7FS LTE -V P/N:TG7LVF01 CFLI__LJLAR til1..,AF,'1°-I C0iMISIUNICC! 9 01 FOR LIE NETWORKS Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in -building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories • ACD 12, ACD 35, ACD 50, ACD 100: 12/35/50/100 feet of low loss, high performance cable. • HGDL-0: High gain directional antenna. • EXDL-0: External antenna. UL Listings Commercial Fire 864 • Control units & accessories for fire alarm systems Commercial Burglary 365 •. Police Station connected burglar alarm units and systems 1610 • Central station burglar alarm units; Line security servcies Residential 985 Household fire warning systems 1023 •:Household burglar alarm systems • For the most current product specifications and UL Listings visit www.Telguard.com. Telguard, a Division of Telular Corporation • 3225 Cumberland Blvd SE • Suite 300 • Atlanta, GA 30339 USA 800-229-2326, Option 5 • www.Telguard.com • Copyright ©2017 Telular Corporation • All Rights Reserved *04-07-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 Listing Expires) June 30, 2022, Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL (9 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7300-1402:0110) Page 1 of 1 CATEGORY: ,7300--FIRE ALARM CONTROL UNIT ACCESSORIES/MISC.DEVICES!. LISTEE:�TELULAR cORP.3325�Cumberland Blvd, NE, Suite 300, Atlanta, GA 30339 Contact: Dale Williams (800) 229-2326 Fax (678) 945-1651 Email: customerservice.telular@ametek.com DESIGN: Models *TG7LV001, *TG7LVA01,i*TG7LVF01 and TG-KIT(digital cellular communicator) system. Models are: digital cellular radio alarm transmission devices .. used to provide a! ,primary (sole or with a back-up);or back-up(transmission path using catlular)for control communicators. Refer to listee's printed data sheet for additional detailed product description and operational considerations RATING: 120 Vac INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices. Refer to listee's Installation Instruction Manual for details. NOTE: Burglary and other non-fire functions were not examined. *04-07-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 Listing Expires) June 30, 2022, Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division NP/NPX SERIES SEALED RECHARGEABLE LEAD -ACID BATTERIES' YUASA NPfNPX INDUSTRIAL BATTERIES Yuasa brand NP and NPX batteries give excellent performance in either float or cyclic applications. These batteries are designed for light duty cyclic applications, fire and security systems, Emergency lighting, solar and wind support systems, UPS systems and loyal ) ro • N RMA CAPACITY [M :. On) On.l Ind. TERMINALS n4l WEIGHT LAYOUT NP SERIES NP3.2-6 - 6 1.2 97 3.82 25 0.98 54.5 2.15 0.3 0.66 1 A 'NP36 3 134 '--528 34: 133 64. 252 `:065 143> 1 A NP4-6 - II 4 70 2.76 47 1.85 105.5 4.15 0.85 1.87 5 A >NP76 7: 151 "595 34 1.33 97.5 3.84 :.335 2.98: 1 A NP10-6.. - 10 .1511 5.95 50 1.9]. 9].5 3.84 2 4.43 1 A NP3.212 2 1.2 : 97 3.82 48: 189 54.5 2.15. .057 1.25: 3 A NP2.3-12FR 2.3 178 7.01 34 1.34 64 2.52 0.94 2.07 1 A G NP412 4 - 90 :354 70.: 276 '406 41 -17 374'. 1 A z a MOAN Mi dosem; @Q% @ ash a C NP1212 NP3212FR:- 12>. 151 `5.94 98 .: 386 97.5 384 44 882.. 4 D NP38-12B NP18-12BFR 17.2 1 181 7.13 76.2 2.99 167 1 6.57 1 6.2 1 13.64 2 E NP2412 NP2412FR-' 24 166 : ^:654 1J5 -. 6,89 325 492 : 8.65 19051 2 C NP2412B NP24-128FR 24 166 6.54 175 6.89 125 4.92 865 19.05 2 E -141238120 NP38-126FR 38 197 774 165:. 65 .175 1 689 138 30.4-:: 2 F - NP65-12FR 65 .350 13.78 165 6.54. 174 1 6.85 22.8 50.2 2 G NPX SERIES - - . NPX50 6 SOW/cell 151 t `595 50 1.97 .97.5 3.84 -.2 4.41:-. 1 A NPX-25 NPX-25FR 32 23W/Cell 90 3.54 70 2.75 106 4.17 2 4.41 1 0 'NPX-35 .NPX-35FR- 35W/Cell 151- 5.94 65-. 256 97.5 384. :265 6.17'-. 4 .A/D - NPX-80BFR 80W/Cell 181 7.13 76.2 2.99 167 _ 6,57 6.6 14.5 2 E NPX-80RFR. .: BOW/Cell 181.: . 7.13 76.2'. 299 -.167 69 '66 145'-. 2 NPX-IOORFR 95W/Cell 166 654 125 492 175 6,89 93 20.0 2 NPX-150RFR: 150W/Cell 197 7.76 165: '. 65 175 6.89.:'15.5 34,1':'. 2 'DASA NP/NPX SERIES YUASA SEALED RECHARGEABLE LEAD -ACID BATTERIES The Yuasa brand of small valve -regulated batteries have, since their introduction, set the standard for quality and excellence in the field of rechargeable sealed lead -acid battery technology. This standard has been used as a benchmark in applications such as security, uninterruptible power supplies (UPS), emergency lights and medical equipment. Anywhere the need for reliable and dependable back-up power is required, Yuasa sets the pace. The Yuasa brand NP product line covers the entire spectrum of battery sizes, ranging from 1.2 Ah to 65Ah in 6 and 12 volt varieties. Yuasa also offers a full line of flame retardant batteries (UL94-V0, L0130). Designated "FR", these batteries comply with UL1778 flame retardant specifications for UPS. Yuasa also offers the NPX Series Batteries, designed for high rate discharge applications. These batteries are used primarily where high wattage is required for a short duration. With 50% more wattage available and a 30% reduction in size over conventional batteries, the NPX Series offers a superior value, especially in UPS applications. RELATIONSFRP REMEN CHARGING. VOLTAGE AND TEMPERATURE E ss: >' T lZ � �lil {f IM I ill w it so FLOAT SFAVKE lliE RP SERIES ihv"iilt}tx�MNR(In'3, fLu4Tt:itiiM1 M;C i2t'1SFT3aNC7R}. igB11iV't Y6htd9'RM1t;RF-4R' ITi:t'f Vnt'F 9ti fiS3'A 1�Ng1 i Coli{YltRy ®lil•ililiA CGSYUASA GS Yuasa Energy Solutions, Inc. 2 CYCFE SEM" OFF 1N RE1JyMM TO OEM Of DW"APGE NP SERIES Fk5l1?iG Ct}MlAiW\ti: [MSYIiA}!Cdi L'iJkNF'VT, O.E'Y' Ate. tt.}; 1.7V,L111 C1inkOLV3t;L'AAF>Y:bUidem�.. C}Ihfttii G M1T14A1ldk. 4,}XUf 44FT tfP t'#PACFFt' Co 7 ,SfRIFF:UF 1Fix{iFlVi1G:� tut t6r,F lf a76] yee U 9 v i A NUMBER OF CWLE.S so FLOAT SFAVKE lliE RP SERIES ihv"iilt}tx�MNR(In'3, fLu4Tt:itiiM1 M;C i2t'1SFT3aNC7R}. igB11iV't Y6htd9'RM1t;RF-4R' ITi:t'f Vnt'F 9ti fiS3'A 1�Ng1 i Coli{YltRy ®lil•ililiA CGSYUASA GS Yuasa Energy Solutions, Inc. 2 M;C i2t'1SFT3aNC7R}. igB11iV't Y6htd9'RM1t;RF-4R' ITi:t'f Vnt'F 9ti fiS3'A 1�Ng1 i Coli{YltRy ®lil•ililiA CGSYUASA GS Yuasa Energy Solutions, Inc. 2 ®lil•ililiA CGSYUASA GS Yuasa Energy Solutions, Inc. 2 CGSYUASA GS Yuasa Energy Solutions, Inc. 2 SYSTEM Pnot,oee�t�< `Smoke' De+ ec WMI System Sensor i3" series smoke detectors represen significontadvancementin conventional detecti The i3 family is founded on three principles: instal, _... _. . ease, intelligence, and instant inspection. Features Installation ease.The P line redefines installation ease with its Plug-in detector line, mounting base included Large wire entry port In-line terminals with SEMS screws Mounts to octagonal and. single -gang back boxes, 4 -square back boxes, or direct to ceiling. Stop-Drop'N Lock attachment to base Removable detector cover and chamber Built-in remote maintenance signaling Drift compensation and smoothing algorithms Simplified sensitivity measurement Wide-angle, dual -color LED indication Loop testing via EZ Walkfeature Built-in test switch Agency Listings �� FM MEA MSFM C LISTED aPPsuveu approved approved c us 5911 3011446 0#216s3,151 � 290 01-E 2093 3180932 plug-in design.This allows an installer to pre -wire bases (included with heads).The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base.The base accommodates a variety of back box mounting methods as well as direct mounting with drywall anchors.To complete the installation, i3 heads plug into the base with a simple Stop-Drop'N Lock" action. Intelligence. 13 detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the 13 line to minimize nuisance alarms. 2 -wire 13 detectors can generate a remote LED - indicated maintenance signal when connected to the 2W-MOD2 loop test/maintenance module or a panel equipped with the 13 protocol.The SENS-RDR, a wireless device, displays the sensitivityof 13 detectors in terms of percent -per -foot obscuration. Instant inspection.The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out -of -sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the 13 protocol, the EZ Walk loop test feature is available on 2 -wire 13 detectors.This feature verifies the initiating loop wiring by providing LED status indication at each detector. Smoke Detector Smoke detector shall be a System Sensor i3 Series model number listed to Underwriters Laboratories (i for Fire Protection Signaling Systems.The detector shall be a photoelectric type (Model 2W -B, 4W -B) or a combination photoelearic/thermal (Model 2W7 -B, 4Wi-B) with thermal sensor rated at 135°F (57.2'C). The detector shall include amounting base for mounting to 3'/rinch and 4 -inch octagonal, single -gang, and 4 -inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws. The detector shall allow pre -wiring of the base and the head shall be a plug-in type. The detectorshalI have a nominal sensitivity of 2.5 percent -per -foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The deteac r shall provided ual- color rovidedual- color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT-B, 4WT-B) conditions. When used in conjunction with the 2W-MOD2 module, 2 -wire models shall include a maintenance signal to indicate the need formal ntenance at the alarm control panel and shall provide a loop testino capability to verify the circuit without testinq each detector individually. Minimum: 8.5V Maximum: 35V 30% peak to pea 20 mA@12 V, 23 2 -wire: 100 uAi 4 -wire: Fara Alarm Contact Ratings Physical Specifications 2 -wire: n/a;4-wire: 0.5 A@30V AC/DC Dimensions (including base) 5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 6.3 oz (178 g) Operating Temperature Range 2W -B and 4W-B:32°F to 120'F (OC to 49°Q;2Wi-B and 4Wi-B: 32°F to 100°F(OC to 37.8°Q Operating Humidity Range Oto 95%RH non -condensing Thermal Sensor 135°F (57.2°C) fixed PreezeTrouble 2WT-13 and 4WT-B only:41°F(5°C) Sensitivity 2.5%/ft nominal Input Terminals 14 to 22 AWG Mounting 3'd -inch octagonal back box 4 -inch octagonal back box Wiring 00 Single -gang back box 2Wi-B Yes flinch square back box with a plaster ring 130 mA max. limited by control panel Direct mount to ceiling LED Modes Power -Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Powerup Blink every 10 seconds Blink every 10 seconds Initial LED status indication 805econds Normal (standby) Blink every 5 seconds off Out of sensitivity off Bl ink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information Model Thermal W (0,69 Wiring 00 Alarm Current `1.3TmAX[na7c li(r)"9f„er7 by tOgtra�WHO 2Wi-B Yes 2 -wire 130 mA max. limited by control panel 4W -B No 4 -wire 20 mA@12V, 23 mA@24V 4Wi-B Yes 4 -wire 20 Fri @12 V, 23 mA@24V Accessories 2W-MOD2 2 -wire loop test/ maintenance module RT SENS-RDR Sensitivity reader A77-AB2 Removal/ replacement tool Retrofit adapter bracket, 6.6 inch (16.76 cm) diameter SYSTEM .SENSOR" ®3artnge it out no, 38250hio Avenue•St. Charles, IL 60174 noaua:a�<:m,:�omeR'omangew�moo'nni«.wlvalme,eren,o,.<o,nro, Phone: 800-SENSOR2• Fax: 630-377-6495 <°^<°'wpopeunm,malmn.incithe latest version oida'ashave, Ax 0316e0] -U09.32169 I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 19 LISTING No. 727fi165 9152] Page 1 of 1 CATEGORY: ;7272 SMbKE,DETEC,TOR-SYSTEM TYPE-pHOTO�LECTRtC LISTEE: fSystem'Sensof. Unincorporated Div of Honeywell Int'I Inc.3825 Ohio Ave, St. Charles, IL 60174 MARKING: Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 APPROVAL: Email: lisa.brant@honeywell.com DESIGN: €Models 21N B2WT-B, 4W -B, and 4WT B(phdtoelectnc type smoke detector`s) Models 2W -B NOTE: and 2WT-B are 2 -wire and models 4W -B and 4WT-B are 4 -wire detectors. Models 2WT-B and 4Wr-B employ a thermistor type heat sensor (135°F). The heat sensor is supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. *The above models comply with UL 268, Seventh Edition. RATING: 8.5 - 35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/min. NOTE: Formerly 7272-1209:210 *Revision 09-21-20 V W W This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not ^;. an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 LlshilgjExpires ------- Authorized ---- Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division System Sensor 2 -wire Compatibility forMS-5UD-3 by Fire -Lite SEASOR octo3mr,c5 imm s n ao 1984. Manufact ret, 011W te) Il`9gtlel + 1W UD -3i Detector Base MaxZone Model Style EOL Zone Model Model Detectors ID W8 N/A 20 N/A / CAC- B D* 4.7K / A 5X N/A 2WT-B N/A 20 N/A / CAC- B D* 4.7K / A 5X N/A 2WTA-B N/A 20 N/A / CAC- B D* 4.7K / A SX N/A 2WTR-B N/A 1 N/A / CAC- B D* 4.7K / A SX N/A *CAUTION: Fire alarm control panels vary by manufacturer on the implementation of Style D (also called Class A) circuits. Therefore, the only way to insure the proper operation of 2 -wire i3 smoke detectors on a Style D initiating device circuit (IDC) is to use a System Sensor 2W-MOD2 module. Any 2 -wire i3 smoke detector (2W -B, 2WT-B, 2WTA- B, or 2WTR-B) wired in the Style D initiating device circuit (IDC) configuration requires the use of a System Sensor 2W-MOD2 module. Page 1 of 1 http://www.systemsensor.com/html/2wirprnt.php?page=2-wire&panel=MS-5UD-3&co=Fir... 5/6/2009 @)POTTER The Symbol of Protection • Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. • Shock hazard.. Disconnect power source before servicing. Serious injury or death could result. • Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. General Information The Model VSR is a vane type waterflow switch for use on wet sprinkler systems. It is UL Listed and FM Approved for use on steel pipe; schedules 10 through 40, sizes 2" thru 8" (50 mm thru 200 mm). LPC approved sizes are 2" thru 8" (50 mm thru 200 mm). See Ordering Information chart. The VSR may also be used as a sectional waterflow detector on large systems. The VSR contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a flow of 10 GPM (38 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. Enclosure The VSR switches and retard device are enclosed in a general purpose, die-cast housing. The cover is held in place with two tamper resistant screws which require a special key for removal. A field installable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin number 5401103 for installation instructions of this switch. Installation (See Fig. 1) These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they should be installed on the top side of the pipe where they will be accessible.. The device should not be installed within 6" (15 cm) of a fitting which changes the direction of the waterflow or within 24" (60 cm) of a valve or drain UL, CULand CSFM Listed, FM Approved,LPCBApproved,For CE Marked (EN12259-5) / VdSApproved model use VSR-EU Service Pressure: 450 PSI (31 BAR) - UL Flow Sensitivity Range for Signal: 4-10 GPM (15-38 LPM) -UL Maximum Surge: 18 FPS (5.5 m/s) Contact Ratings: Two sets ofSPDT(Form C) 10.0Amps at 125/250VAC 2.0 Amps at 30VDC Resistive 10 mAmps min. at 24VDC Conduit Entrances: Two knockouts provided for 1/2" conduit. Individual switch compartments suitable for dissimilar voltages. Environmental Specifications: • NEMA 4/IP54 Rated Enclosure suitable for indoor or outdoor use with factory installed gasket and die-cast housing when used with appropriate conduit fitting. • Temperature Range: 40°F -120°$(4.5°C -49°C) -UL • Non -corrosive sleeve factory installed in saddle. Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 Optional: Cover Tamper Switch Kit, stock no. 0090148 Replaceable Components: Retard/Switch Assembly, stock no. 1029030 Note: Do not leave cover off for an extended period of time Drain the system and drill a hole in the pipe using a hole saw in a slow speed drill. (see Fig. 1) Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterflow. Install the saddle strap and tighten nuts alternately to required torque. (see Fig. 1). The vane must not rub the inside of the pipe or bind in any way. Specifications subject to change without notice. Potter Electric Signal Company, LLC • 2081 Craig Road, St. Louis, MO, 63146-4161 -Phone: 800-325-3936/Canada888-882-1833•w ..pottersignat.wm PANTED M USA MFG. #5401146 -REV K PAGE l OF 3 12/08 Ordering Information Nominal Pipe Size Model Part Number 2" DN50 VSR-2 1144402 21/2" DN65 VSR-21/2 1144425 3" DN80 VSR-3 1144403 31/2" - VSR-31/2 1144435 4" DN100 VSR-4 1144404 Y - I VSR-5 1144405 6" DN150 VSR-6 1144406 8" DN200 VSR-8 1144408 Potter Electric Signal Company, LLC • 2081 Craig Road, St. Louis, MO, 63146-4161 -Phone: 800-325-3936/Canada888-882-1833•w ..pottersignat.wm PANTED M USA MFG. #5401146 -REV K PAGE l OF 3 12/08 @P01 The Fig.l (Flavin¢water activates device in one direction on19.1 MOUNTON ;1— POI WDIR�lm VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD Fig. 3 Typical Electrical Connections N GATNE nCOR NEUrR AC OsTr1w GC RHOTAC LOWZONE PANEL Notes: 1. The ModelVSRhas two switches, one can be used to operate a central station, proprietary or remote signaling unit, while the other contact is used to operate a local audible or visual annunciator. 2. A condition of LPC Approval of this product is that the electrical entry must be sealed to exclude moisture. 3. For supervised circuits see "Switch Terminal Connections" drawing and caution note (Fig. 2). PRINTED IN USA Fig. 2 Switch Terminal Connections Clamping Plate Terminal An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire become dislodged from under the terminal. Failure to sever the wire may render the device inoperable risking severe property damage and loss of life. Waterflow switches that are monitoring wet pipe sprinkler systems shall not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. Waterflow switches used for this application may result in unintended discharges caused by surges, trapped air, or short retard times. Fig.4 Fig:5 Break out thin section ofcover when wiring both To ,move knockouts: Place screwdriverat 1 Installation Requirements inside edge of knockouts, not in the center. Model Nominal Pipe Size Nominal Pipe O.D. Hole Size U-BoltNuts Torque inch mm inch mm inch m m 11-16 n -m VSR-2 2 DN50 2.375 60.3 1.25+.125/-.062 33.0 t2.0 20 27 VSR-212 212 2.875 73.0 VSR-21/2 212 DN65 3.000 76.1 VSR-3 3 DN80 3.500 88.9 2.001.125 50.832.0 VSR-312 3l2 4.000 101.6 VSR4 4 DN100 4.500 114.3 VSR-5 5 5.563 141.3 VSR-6 6 DN150 6.625 168.3 VSR-8 8 DN200 8.625 219.1 Fig. 3 Typical Electrical Connections N GATNE nCOR NEUrR AC OsTr1w GC RHOTAC LOWZONE PANEL Notes: 1. The ModelVSRhas two switches, one can be used to operate a central station, proprietary or remote signaling unit, while the other contact is used to operate a local audible or visual annunciator. 2. A condition of LPC Approval of this product is that the electrical entry must be sealed to exclude moisture. 3. For supervised circuits see "Switch Terminal Connections" drawing and caution note (Fig. 2). PRINTED IN USA Fig. 2 Switch Terminal Connections Clamping Plate Terminal An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire become dislodged from under the terminal. Failure to sever the wire may render the device inoperable risking severe property damage and loss of life. Waterflow switches that are monitoring wet pipe sprinkler systems shall not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. Waterflow switches used for this application may result in unintended discharges caused by surges, trapped air, or short retard times. Fig.4 Fig:5 Break out thin section ofcover when wiring both To ,move knockouts: Place screwdriverat 1 switches from one conduit entrance. inside edge of knockouts, not in the center. MFG. #5401146 - REV K 12/08 PAGE 2 OF 3 (E)POTTER VSR VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD Note: For copper or plastic pipe use Model VSR-CF. Testing The frequency of inspection and testing for the Model VSR and its associated protective monitoring system should be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). Ifprovided, the inspector's test valve, that is usually located at the end of the most remote branch line, should always be used for test purposes. If there are no provisions for testing the operation of the flow detection device on the system, application of the VSR is not recommended or advisable. A minimum flow of 10 GPM (38 LPM) is required to activate this device. Maintenance Inspect detectors monthly for leaks. If leaks are found, replace the detector. The VSR waterilow switch should provide years of trouble-free service. The retard and switch assembly are easily field replaceable. In the unlikely event that either component does not perform properly, please order replacement retard switch assembly stock #1029030. There is no maintenance required, only periodic testing and inspection. Removal • To prevent accidental water damage, all control valves should be shut tight and the system completely drained before waterflow detectors are removed or replaced. • Tum off electrical power to the detector, then disconnect wiring. • Loosen nuts and remove U -bolts. • Gently lift the saddle far enough to get your fingers under it. With your fingers, roll the vane so it will fit through the hole while continuing to lift the waterllow detector saddle. • Lift detector clear of pipe. Important Notice Please advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. Mounting Dimensions EWs T_ 59,4 mm Compatible Pipe U-BOLTNm U-BOLTWASHER Model Nominal Pipe Size Nominal Pipe O.D. Pipe Wall Thickness Schedule 10 (UL) Schedule 40 (UL) BS -1387 (LPC) DN (VDS) inch con inch mm inch mm inch mm inch mm inch mm VSR-2 2 DN50 2.375 60.3 0.109 2.77 0.154 3.91 0.142 3.6 0.091 2.3 VSR-21/2 21/2 2.875 73.0 0.120 3.05 0.203 5.16 VSR-21/2 DN65 3.000 76.1 0.142 3.6 0.102 2.6 VSR-3 3 DN80 3.500 88.9 0.120 3.05 0.216 5.49 0.157 4.0 0.114 2.9 VSR-312 312 4.000 101.6 0.120 3.05 0.226 5.74 VSR-4 4 DN100 4.500 114.3 0.120 3.05 0.237 6.02 0.177 4.5 0.126 3.2 VSR-5 5 5.563 141.3 0.134 3.40 0.258 6.55 VSR-6 6 DN150 6.625 168.3 0.134 3.40 0.280 Zl] 0.197 5.0 0.157 4.0 VSR-8 8 DN200 8.625 219.1 0.148 3.76 0.322 1 8.18 1 0.248 6.3 0.177 4.5 Note: For copper or plastic pipe use Model VSR-CF. Testing The frequency of inspection and testing for the Model VSR and its associated protective monitoring system should be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). Ifprovided, the inspector's test valve, that is usually located at the end of the most remote branch line, should always be used for test purposes. If there are no provisions for testing the operation of the flow detection device on the system, application of the VSR is not recommended or advisable. A minimum flow of 10 GPM (38 LPM) is required to activate this device. Maintenance Inspect detectors monthly for leaks. If leaks are found, replace the detector. The VSR waterilow switch should provide years of trouble-free service. The retard and switch assembly are easily field replaceable. In the unlikely event that either component does not perform properly, please order replacement retard switch assembly stock #1029030. There is no maintenance required, only periodic testing and inspection. Removal • To prevent accidental water damage, all control valves should be shut tight and the system completely drained before waterflow detectors are removed or replaced. • Tum off electrical power to the detector, then disconnect wiring. • Loosen nuts and remove U -bolts. • Gently lift the saddle far enough to get your fingers under it. With your fingers, roll the vane so it will fit through the hole while continuing to lift the waterllow detector saddle. • Lift detector clear of pipe. Important Notice Please advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. Mounting Dimensions EWs T_ 59,4 mm (2.34") U-BOLTNm U-BOLTWASHER PIPE SADDLE PIPE PLASTIC PADDLE U -BOLT NOMINAL PIPE DIA. +44,5 nun (+ 1-3/4) FOR DN50-DN65 (2.2-Ia' NOMINAL PIPE DU. +54,0 mm (+2-1 /8") FOR DN80 - DN200 (3.8") PIPEDIA. +133,4 mm (-5-1/4") DWG#114L PRINTED IN USA MFG. #5401146 - REV K PAGE 3 OF 3 12/08 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE t9 LISTING No. [77ZOy0328 OOOt;= Page 1 of 1 CATEGORY: o777Q VALVE$!$VVfT.�HE$J LISTEE: (potter-E}eiatrlc Slgn„�I dp1609 Parki,370 Piacs`,� Hazelwood, MO 63042 United States Contact: Brad Serangeli (314) 666 -6606 -Fax (314) 595-6999 Email: brads@pottersignal.com DESIGN: Vane and pressure type;, switcfigs?listed below. Refer to listee's data sheet for detailed product description and operational considerations. Vane Types: VSR-CF VSR-D VSR-F VSR-SF VSR-FE-2 VS -SP VS -F VSR-SFG VSR-SFT VSG {VSR; VSR-S VSR-C VSR-ST VSR-SG Pressure Type: WFS-B WFSR-C WFSPD-B PS10 PS -10A PS -100A WFSR-F PS100 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL or FM label. APPROVAL: Listed as waterflow alarm switches for use with fire sprinkler systems. Vane models may be used in wet pipe systems; pressure models may be used in wet or dry systems. Model VSR-CF is for use on K, L or M copper pipe (2", 2-1/2", 3", 4") and listed CPVC pipe (2", 2-1/2", 3"). Model VSR-SF for use on 1", 1-1/4", 1-1/2" and *2" steel, copper or listed plastic pipe. Model VSG is for low flow rate. Model VSR-SFG and VSR-SFT are for use on 1", 1-1/4", 1-1/2" and *2" plastic pipe. Models VS -F, VSR-F, VSR-FE and VSR-FE-2 is for use on 2", 2-1/2", 3", 3-1/2", 4", 5", 6", 8" and 10" pipe. *Model VSR is for use on steel pipe sizes from 2" through 8". Vane type switches may be used outdoors when the outdoor temperature never falls below 40oF. Rev*5-17-2007 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division (E)POTTER The Symbol of Protection Conduit Entrances: Two knockouts for 1/2" conduit provided. Service Use: monitoring the open position of fire sprinkler control valves of the post Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 UL, ULC, and CSFM Listed, FM Approved, NYMEA Accepted, CE Marked Dimensions: 4.75"L x 2.25'W x 8.2"14 (stem extended) 12,Icm L x 5,7cm W x 18,3cm H Weight: 1.35 lb. (0,61 kg.) Enclosure: Cover -Die-cast Finish - Red Spatter Enamel Base - Die Cast Zinc All parts have corrosion resistant finishes. Cover Tamper: Tamper Resistant Screws, Optional cover tamper kit available Mounting: 1/2" NPT Contact Rating: PCVS-1: One set of SPDT (Form C) PCVS-2: Two sets of SPDT (Form C) 15.00 Amps at 125/250VAC 2.50 Amps at 30VDC resistive Environmental Limitations: 40"F to +140017 (400C to 60°C) NEMA 4 and NEMA 6P Enclosure (IP67) when used with appropriate watertight conduit fittings. Indoor or Outdoor Use (Not for use in hazardous locations. See bulletin no. 5400694 PNS -U -EX for hazardous locations.) The Model PCVS is a weather proof and tamper resistant switch for should belefrwith the buildingownerorresponsible party. Replacement monitoring the open position of fire sprinkler control valves of the post or additional cover screws and hex keys are available. See ordering indicator, butterfly and other types. Depending on the model, one or information. two SPDT (Form C) contacts are provided which will operate when the Optional Cover Tamper Switch valve position is altered from an open state. Afield installable covertamperswitchisavailable asanoptionwhichmay The unit mounts in a 12" NPT tapped hole in the post indicator or be used to indicate removal of the cover. See ordering information. butterfly valve housing. The device is engaged by the indicating Hex Key for Cover Screws and Installation Adjustments assembly of the post indicator or the operating mechanism of the Testing butterfly valve, actuating switches) when the valve is fully open. The The PCVS and its associated protective monitoring system should be unit should be installed where it is accessible for service. tested in accordance with applicable NFPA codes and standards and/or The cover is held in place by two tamper resistant screws that require the authority having jurisdiction (manufacturer recommends quarterly a special tool to remove. The tool is furnished with each device and or more frequently). Ordering Information Model Description Stock No. PCVS-1 Potter Control Valve Switch (single switch) 1010107 PCVS-2 Potter Control Valve Switch (double switch) 1010207 — Cover Screw 5490344 -- Hex Key for Cover Screws and Installation Adjustments 5250062 PBK-S Pratt Butterfly Valve Kit - Up to 12" (300mm) 0090133 PBK-L Pratt Butterfly Valve Kit - 14" (355mm) and Up 0090132 PVK Pratt Valve Kit 1000060 -- Optional Cover Tamper Switch Kit 0090131 KBK Kennedy Butterfly Valve Kit 0090143 For pressure reducer type valve installation kits (if required) contact valve manufacturer Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146A 161 • Phone: 800-325-3936/Canada 888-882-1833 • wwavpottersignal.com PRINTED IN USA MKT. 48820001 - REV U PAGE 1 OF 4 MEG. 45400980 - 9/07 @POTTER CONTROLVAILVE The Symbol of Protection SUPERVISORY SWITCH Fig.I Dimensions Fig.2 Parts R( (5.7.) t 1 ligan) )' �( DWD#9062 " 'RJPROD RODIXiENOFD V DWcn saa� Typical Installations On Post Indicator Valve Housings (See Figs.3 Thru 6) Refer to Fig 2 fmthe location ofpans descnbed in the following instructions. Note: Ifthe sprinkler system is in service the owner or authorized representative should be notified, before any work is done on the system, that the valve controlling the water supply to the system may be closed for periods of time during the installation and testing of this device, resulting in all or portions of the system being inoperative during these periods. If the system is not in service and valve is closed, be sure that opening the valve will not allow any unwanted water flow due to openings in the system, such as heads off, broken or incomplete piping, etc. I. Position the valve to fully open ("OPEN" should appear in the window of the housing). Partially close the valve while observing the direction that the target assembly moves. Reopen the valve. If the valve housing is predrilled with a 1/2" NPT for installation of a monitoring switch, remove the 12" plug and fully open the valve. Make sure that "OPEN" appears in the window of the housing. GO TO STEP NO. 6. 2. Remove the head and target assembly (consultation with valve manufacturer is recommended). 3. If the target assembly moved up as the valve was closed, measure the distance from the bottom of the head to the lower part of the target assembly that will contact the trip rod of the PCVS (see Fig. 3). This is usually a plate or bar on the target assembly, on a side adjacent to the "OPEN/SHUI— plates. Subtract 1/8" from the measurement. Ifthe target moved down as the valve was closed, measure the distance from the bottom ofthe head to the upper portion of the target assembly that will contact the trip red ofthe PCVS (see Fig. 4). Add 1/8" (3,2mm) to this measurement. 4. Mark the housing at the proper location. Using a 23/32" (18,2mm) drill bit, drill andthen tap a 1/2" NPT in the housing on the side that coincides with the portion of the target assembly that will engage the trip rod of the PCVS. 5. Replace the head and target assembly. 6. Loosen the socket head screw that holds the nipple in the PCVS and remove the nipple. 7. Screw the lockout that is provided onto the nipple. 8. Screw the nipple into the 12" NPT hole in the valve housing - hand tightcu. Tighten the locknut against the valve housing to secure the nipple firmly in place. 9. Insert a scale or probe thin the nipple to measure the distance from the open end of the nipple to the target assembly. Subtract 12" (12,5mm) from this measurement. NOTE: In some cases, it may be necessary to attach an angle bracket to the target assembly to engage the PCVS trip rod. 10. Usingthe special tool provided,loosenthe two covmscrewsandremove the cover from the PCVS. 11. Loosen the locking screw that holds the trip rod in place and adjust the rod length, from the end of the collar to the end of the rod, using the dimension determined in Step 9. Tighten the locking screw to hold the rod in place. NOTE: If trip rod length is excessive, loosen the locking screw and remove the trip rod from the trip lever. Using pliers, break off the one (1) inch long notched section (see Fig. 7). Reinstall trip rod and repeat Step 11 procedure. 12. Partially close the valve (3 to 4 revolutions ofthe handlellrandwheel). 13. Slide the PCVS unit as far as possible onto the nipple, observing which direction the rod will move when the valve is closed. Orient the device to actuate the switches when the valve is open. Tighten the socket head screw in the collar. 14. Carefully open thevalvetothe fully opeaposition. Asthetargetmovesto the open position it should engage the trip m d and actuate the switch(es). There should be a minimum overtravel of I2 revolution of the handle/ hand wheel after the switch(es) actuate (a continuity meter connected to each set of contacts is one method that could be used to determine this). 15. Slowly close the valve. The switch must operate during the first two revolutions ofthe bandle/hand wheel or during 1/5 ofthe travel distance of the valve control apparatus from its normal condition. NOTE: Small adjustments of the target position may be necessary (consultation with valve manufacturer is recommended). 16. Complete the required electrical wiring, connections and tests. The valve should be operated through the entire cycle of fully closed and fully open to determine the integrity of the PCVS installation and the signaling system. Check that all electrical and mechanical connections are secure. 17. When the installation andtesting are complete, return valve to its proper position. 18. Alternative installation for other post indicator valve housing shown in Fig. 5 and 6. PRINTED IN USA MKT 48820001 - REV U PAGE 2 OF 4 WG. 45400980 - 9/07 CONTROL ONTROL(P)POTTER , -2 VALVE The Symbol of Protection SUPERVISORY SWITCH Fig.3 Fig. 4 Fig. 5 Fig. 6 Notes: KHFTA PLATE REPLACES GIASs 1. Subject to the approval of the "authority having jurisdiction" the 2. If the target is stationary and a hood arrangement is used, such as alternate method of installation shown in Fig. 5 may be used. In is shown in Fig. 6, the hood must he drilled with a 23/32" drill and this method, one of the glass windows of the housing is replaced tapped with a 1/2" NPT. The center line of this hole should be 1/8" with a 1/4" thick metal plate that is cut to fit in place of the glass below the portion of target assembly that strikes the PCVS trip and drilled and tapped to receive the 1/2" NPT pipe nipple. In rod. The 113/8" dimension shown is for a Clow Valve. Flexible some cases it may be necessary to attach an angle bracket to the conduit must be used for this type of installation. target assembly to engage the PCVS trip rod. Typical Installation On A Butterfly Valve (See Figs. 9 And 10) Refer to Fig. 2 for location of parts described in the following instructions: Bl. B2. B3. B4. B5. B6. B7 Remove the 1/2" NPT plug from the gear operator case. Laasenthe setscrewthatholds &nipple mthePCVS andremovethe nipple. Screw the lockout that is provided onto the nipple. Screw the nipple into the 1/2" NPT hole in the gear operator - hand tighten. Tighten the locknut against the case, to secure the nipple firmly in place. Partially close the valve (3 m4 revolutions ofthe hand wheel or crank). Using the special tool provided, loosen the two cover screws and remove the cover from the PCVS. Loosen the locking screw that holds the trip rod in place. Estimate trip rod length required and extend slightly past that point. Slide the PCVS unit as far as possible onto the nipple, observing which direction the rod will move when the valve is closed. Orient the device to actuate switches when valve is open. Note: If trip rod length is excessive, loosen the locking screw and remove the trip rod from the trip lever. Using pliers, break off the one (1) inch long notched section (see Fig. 7). Reinstall trip rod and repeat Step B7 procedure. FSg. 7 Breaking Excessive Rod Length 0 � uwc•seo-n PRINTED IN USA B8. Remove device from nipple and withdraw trip rod 1/32"(0,80mm) (this dimension is important). Tighten the locking screw to hold the rod in place. Re -install the device on the nipple. Tighten the screw in the collar against the nipple. Note: In some cases it may be necessary to remove the gear box cover to ensure correct operation (consultation with the valve manufacturer is recommended). B9. Carefully open the valve to its full open position, as the boss on the gear hub moves to the open position it must engage the PCVS trip. rod and actuate the switch(es). There should be a minimum overtravel or revolution of the crank or hand wheel atter the switch(es) actuate (a continuity meter connected to each set of contacts is one method that could be used to determine this). Note: ShghtadjuAmemofgear s[opsmaybenecessmytopreventovertmvel ofthetrip Lod (consultation with valve mamuractnm is recummeuded). B 10. Carefully close the valve. The switch(es) must operate during the first two revolutions ofthe crank orhandwheel orduring 1/5 ofthetravel distance of the valve control apparatus from its normal condition. 11I1. Complete the required electrical wiring, connections and tests. The valve should be operated through the entire cycle of fully closed and fully open to determine the integrity of the PCVS installation Fig. 8 Switch Terminal Connections Clamping Plate Terminal A CAUTION An nnsection of a single conductor should notot be fie l looped around the temanal and serveastwo sepamtecomecnons. Theawemust be severed, thereby providing supervision ofthe connection in the event that the awe becomes dislodged from under the terminal. SKT. 48820001 -REV U WG. 95400980 - 9/07 PAGE 3OF4 STEEL M LOLIINIIT RRPIAG BLGCF- TAMPER jj R "as SWIICII OPEx FLVtN6R Q Q TAMER OPE sicncx RGE MGVES BV4GS a SHLT rweaecR t• II3B' SHIN ASSEhIRLY FLEXIBLE coxoun las"°t NGGGM0,. TARGET mows OP ASVALVE ALYE VA=is SNIIF a SIIHP U\YG•9S0.]0 1. Subject to the approval of the "authority having jurisdiction" the 2. If the target is stationary and a hood arrangement is used, such as alternate method of installation shown in Fig. 5 may be used. In is shown in Fig. 6, the hood must he drilled with a 23/32" drill and this method, one of the glass windows of the housing is replaced tapped with a 1/2" NPT. The center line of this hole should be 1/8" with a 1/4" thick metal plate that is cut to fit in place of the glass below the portion of target assembly that strikes the PCVS trip and drilled and tapped to receive the 1/2" NPT pipe nipple. In rod. The 113/8" dimension shown is for a Clow Valve. Flexible some cases it may be necessary to attach an angle bracket to the conduit must be used for this type of installation. target assembly to engage the PCVS trip rod. Typical Installation On A Butterfly Valve (See Figs. 9 And 10) Refer to Fig. 2 for location of parts described in the following instructions: Bl. B2. B3. B4. B5. B6. B7 Remove the 1/2" NPT plug from the gear operator case. Laasenthe setscrewthatholds &nipple mthePCVS andremovethe nipple. Screw the lockout that is provided onto the nipple. Screw the nipple into the 1/2" NPT hole in the gear operator - hand tighten. Tighten the locknut against the case, to secure the nipple firmly in place. Partially close the valve (3 m4 revolutions ofthe hand wheel or crank). Using the special tool provided, loosen the two cover screws and remove the cover from the PCVS. Loosen the locking screw that holds the trip rod in place. Estimate trip rod length required and extend slightly past that point. Slide the PCVS unit as far as possible onto the nipple, observing which direction the rod will move when the valve is closed. Orient the device to actuate switches when valve is open. Note: If trip rod length is excessive, loosen the locking screw and remove the trip rod from the trip lever. Using pliers, break off the one (1) inch long notched section (see Fig. 7). Reinstall trip rod and repeat Step B7 procedure. FSg. 7 Breaking Excessive Rod Length 0 � uwc•seo-n PRINTED IN USA B8. Remove device from nipple and withdraw trip rod 1/32"(0,80mm) (this dimension is important). Tighten the locking screw to hold the rod in place. Re -install the device on the nipple. Tighten the screw in the collar against the nipple. Note: In some cases it may be necessary to remove the gear box cover to ensure correct operation (consultation with the valve manufacturer is recommended). B9. Carefully open the valve to its full open position, as the boss on the gear hub moves to the open position it must engage the PCVS trip. rod and actuate the switch(es). There should be a minimum overtravel or revolution of the crank or hand wheel atter the switch(es) actuate (a continuity meter connected to each set of contacts is one method that could be used to determine this). Note: ShghtadjuAmemofgear s[opsmaybenecessmytopreventovertmvel ofthetrip Lod (consultation with valve mamuractnm is recummeuded). B 10. Carefully close the valve. The switch(es) must operate during the first two revolutions ofthe crank orhandwheel orduring 1/5 ofthetravel distance of the valve control apparatus from its normal condition. 11I1. Complete the required electrical wiring, connections and tests. The valve should be operated through the entire cycle of fully closed and fully open to determine the integrity of the PCVS installation Fig. 8 Switch Terminal Connections Clamping Plate Terminal A CAUTION An nnsection of a single conductor should notot be fie l looped around the temanal and serveastwo sepamtecomecnons. Theawemust be severed, thereby providing supervision ofthe connection in the event that the awe becomes dislodged from under the terminal. SKT. 48820001 -REV U WG. 95400980 - 9/07 PAGE 3OF4 @POTTER The Symbol of Protection ITT Grinnell/Kennedy Indicating Butterfly Valve Fig. 9 PBK- Pratt IBV Butterfly Valve Kit Fig. 12 CALWOMoN DWGO9 BMCRE AND LOCHNI. SUPPLIE WITH PE MOUNT[ KIT Madel PBK-L Stock No. 0090132 (MDT -4S Actuator) Model PSK -M Stock No. 0090146 (MDT -3S Actuator) Model PBK-S Stock No. 0090133 (M1)T-2S Actuator) Pratt Butterfly Valve K0 as used to mount a PCVS on a Pratt Model IBV Valve. Kits contain: Bracket, nuts and instructions Note: This application is subject to the approval of the authority havingjurisdiction. Dresser Indicating Butterfly Valve Fig. 10 (63 -) DWG99tb7 PVK - Pratt VIVA Post Indicator Valve Kit (Stock No. 1000060) Fig. 13 MACHINE SCREW N-32 Pratt Valve Kit as used to meant a PCVS on a Pratt Model PIVA Valve. Kit contains: Instructions, template, screw and nut. Note: This application is subject to the approval of the authority havingjurisdiction. PCVS-19 _2 CONTROL VALVE SUPERVISORY SWITCH Typical Pressure Reducer Type Valve Installation Fig. 11 COLIAR --jr�1lrl�-1r1�'�I LOCKNUT II u I NWPLE PCVS lflfi'(I,finw) MIN. GAP DWG w". Thisfigue showstheModelPCV Smomted onlhevalve yoke, with a bracket supplied by the valve manufacturer, to supervise a pressure reducer type valve. Note: This application is subject to the approval ofthe authority having jurisdiction. Typical Electrical Connections Please Note: This device should be wired in accordance with the applicable pmts of the National Electrical Code, all state and local codes, applicable NFPA Standards and the requirements of the authority havingjurisdiction. Fig. 14 LIXALCWCNT N.O. CON. N.G DEVICE O 'IOPOWaREOa I DEVICE avmcnMGnancE TOSUPERVISORY I N.O. CIRCfIIfOF CONnULL ENp OF LME PANEL Colt ♦ NC. RESISTOR Contacts shown in normal (valve open) condition Typical Switch Action OPEN VALYEPDSn1ON CLOSED V.V,VEPoSDION CON. CON. SW XI Switches Shown in Valve Open Position IN USA MKT. #8820001 - REV U PAGE 4 OF 4 MFG. 95400980 - 9107 WN CONI N.U. COM.IA0. sv NC. swn N.C. DWa"ft,11 Switches Shown in Valve Open Position IN USA MKT. #8820001 - REV U PAGE 4 OF 4 MFG. 95400980 - 9107 LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION: MARKING: APPROVAL: NOTE: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDINGMATERIALSLISTING PROGRAM LISTING SERVICE x7770 VALXB�i�WIT�HESy Page 1 of 1 Potter E�etno Slgnaf Co1609 PartrB/0 Place; Hazelwood, MO 63042 United States Contact: Brad Serangeli (314) 595-6900 Fax (314) 595-6999 Email: brads@pottersignal.com S�1peNIS Swltches•�isted below to monitor pressure, OS&Y, gate, globe/gate, PIV, tank temperature or water level valves. Refer to listee's data sheet for detailed product description and operational considerations. HLS-B WLS-W PS -120A OSYSU-2 PTS -B OSYSU-1 PIVS-B TTS -S WLS PTS -C RBVS *PS15 WLS-S PS -40A OSYS-B PMS GVS (RCVS 1 TTS -W PCVS-2 PS40 PS120 *PS25 In accordance with listee's printed instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model designation and FM or UL label. Listed as sprinkler system supervisory switches. - Formerly 7738-0328:010 *Revision 09-07-2016 do This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 L/sf(igExp/res; cJune30,¢1122 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division PRODUCTS SAFE (SECURITY, ACCESS CONTROL, FIRE ALARM) Insulation: Semi -Rigid PVC Jacket: Flame -Retardant PVC Operating Temperature: -10°C to +75°C1 wmpuance;; r� ,UL7yp`e FI'_LR/ MR/CL3R • C(UL) CMG (14 AWG FPLR/CL3R only) • Passes UL 1666 Riser Flame Test • RoHS Compliant Applications: • Fire Alarm, Signal • Monitor/Detection • Audio or Control Circuits 3 E k#opq 38698, 33551, 33735, 38700 SpecThickness NO Ntonberot, Jacket Jacket 'Ninai, iD�metgr Nurt)ber ,Conductors' (inches) Color ;iintyligs)� Spec Vwp- ......_. __. 3E6961 i2) ...014 ........RED content/uploads/2019/02/DS38696.pdf) _._. Spec Vwp-_.._. ;386971 ,4,� .014. RED , content/uploads/2019/02/DS 38697.pdf) 16 AWG Solid Bare Copper Part Number of Jacket Jacket Nominal Spec Number Conductors Thickness Color Diameter (inches) (inches) Spec (/wp 38698 2 .014 RED .158 conte nt/u p loads/2O19/02/D 538698.pdf) 14 AWG Solid Bare Copper Jacket Nominal Part Number of Jacket Spec Thickness Diameter Number Conductors Color (inches) (inches) Spec ..._.. 33551... 2 _..... .014. YELLOW .....192 ..__ .. _.. Spec .._. 33735..... 2 _.. ..014... ...WHITE .192 _.._.. Spec 38700 2 ..... .014 .. ....RED .192... .... _.... CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 19 LISTING No. 17161'.9295:0100, Page 1 of 1 CATEGORY:FQSLES-FI}2E PROTIt&IVE'SIGNALING LISTEE: 4Corntr:tttab�� ;hLC';330A Turner Street, South Attleboro, MA 02703-7714 Contact: Willy Chu (508) 399-7004 Ext: 260 Fax (508) 399-7360 Email: willy.chu@comtrancorp.com DESIGN:TypesjFPLi FPLR *FPLR-CI, *FPLR-LS, and FPLP. Refer to listee's data sheet for detailed product description and operational considerations. RATING: *Circuit Integrity Rating: 2 hr INSTALLATION: In accordance with listee's printed installation instructions, applicable codes, NEC Article 760, and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, NEC rating and UL label. APPROVAL: Listed as power -limited fire protective signaling cable. Refer to listee's Installation Instruction Manual for details. *Revision 04-02-20 V W W This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed �y the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 LlsfingExpires Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division